HS-105I High Temp
HS-105I
Intrinsically Safe, High Temperature,
100mV/g Industrial Accelerometer (Includes External Charge Amplifier)
SC-305
S/N: 058788
Performance
Mounted Base Resonance............. 22 kHz (nominal)
Sensitivity........................................100 mV/g ±10% Nominal 80 Hz at 71°F (22°C)
Frequency Response..................... 2 Hz to 10 kHz ±5%
0.8 Hz to 15 kHz ±3 dB
Isolation.......................................... Base isolated
Measurement Range..................... ±80 g
Transverse Sensitivity.................... Less than 5%
Mechanical
Case Material..................................Stainless Steel
Sensing Element/Construction....... PZT/Compression
Mounting Torque............................. 8 Nm
Weight............................................. 3.53 oz (100 gms) - nominal
Maximum Cable Length.................. 32.8 ft (10 m) between sensor & charge
amplifier
Mounting Threads........................... See ‘How to order’ table
Options............................................Cable length, various mounts, other
sensitivities
Electrical
Electrical Noise...............................0.1 mg max
Current Range................................ 0.5 mA to 8 mA
Bias Voltage....................................10 - 12 Volts DC
Settling Time...................................2 seconds
Output Impedance.......................... 200 Ohms max.
Case Isolation.................................>108 Ohms at 500 Volts
Environmental
Features
For offline applications using commercially
available intrinsically safe data collectors
and online monitoring systems in the fields
of Offshore, Petrochemical, Gas.
Protecting...
Fans, Motors, Pumps, Compressors,
Centrifuges, Conveyers, Air Handlers,
Gearboxes, Rolls, Dryers, Process
Equipment, and many more.
*Accelerometer
**Charge Amplifier
Certified Temperature Range.......... *Ex ia llC T6 (-4°F ≤ Ta ≤ 482°F)
[-20°C ≤ Ta ≤ 250°C]
**Ex ia llC T4 (-4°F ≤ Ta ≤ 176°F)
[-20°C ≤ Ta ≤ 80°C]
Sensor Temperature Range............ -4 to 482°F (-20 to 250°C)
Sealing............................................ IP65
Maximum Shock..............................5000 g
Emissions........................................ EN61000-6-4:2001
Immunity.......................................... EN61000-6-2:1999
How to Order
HS - Product Prefix
Extra Options
I…ATEX Group II Top Exit
IS…ATEX Group II Side Exit
H S - 1 0 5 I
Product Series
105 - High Temperature
Industrial Accelerometer
Cable
05…Single core, low noise
PTFE rated to 482ºF (250ºC)
1 0 0 0 5 0 2
Output
010…10mV/g
100…100mV/g
HS-105 Series Sensors
Mounting Threads
02…1/4”-28 UNF Male
*Please contact our sales
office to specify the length
of cable before and after
the charge amplifier.
SEC of America, Inc.
4355 Ferguson Drive
Suite 215
Cincinnati, Ohio 45245
ph: 513.453.4560
fx: 513.297.9003
www.sec-america.com