High Density Balun Panel
The aim of this catalogue is to show the range of high quality baluns and balun solutions available
from AC&E. We trust that you will find this booklet helpful in sourcing the products you require.
Founded in 1967, Australian company AC&E has become a leading manufacturer and supplier of
connectivity and interface solutions to the telecommunications, networking, audio/video and
Broadcasting Industries. With sales in 64 countries around the world, AC&E catalogue and
customized solutions are well recognized.
Since its inception, AC&E has specialised in the development and manufacture of products such
as:
x Telecommunication Baluns for 1.5 to 155Mbit/s applications
x Video Baluns for Surveillance, Security and Broadcast applications
x Broadband Baluns for TV and CATV applications
x Coaxial Connectors and U Links primarily in BNC, 1.6/5.6, BT43 and 1.0/2.3
x Audio Video Interconnection and Distribution Products
x Patch Panels
x Cable Assemblies
x Alarm Modules, and Power Distribution Modules for Telecommunications Applications
x Cable TV Products for interface and distribution
x Broadband Interface and Distribution systems for home, apartment or office
AC&E is constantly researching, developing and improving its range of telecommunication
products to provide customers world wide with cutting edge technology. In the past year we have
significantly improved or created new catalogue products providing improved
performance and greater product choice.
AC&E is committed to supplying high quality, high reliability product at
competitive
prices.
We
work
in
accordance
with
quality
standard
ISO9001:2000 and strive for excellence through total quality management
methodology.
Please feel welcome to visit our web site, www.acande.com or contact our
office (address details on the back cover) with any enquiries you may have.
We look forward to assisting you with your requirements and providing a
solution to your connectivity and interface needs.
Page 2
www.acande.com
Table of Contents
Baluns
4
Introduction
Telecommunications Applications
Benefits in Converting DDF from Coax to Twisted Pair
Generic Single Balun Part Numbering
Generic Balun Panel Part Numbering
Electrical Characteristics of 2-8Mbits/s, 75/120 Ω Balun
Electrical characteristics of 34-155Mbits/s 75/120 Ω Balun
4
5
5
6
7
8
9
Standard Baluns
10
Standard Baluns Physical Characteristics
2-8 Mbits/s 75/120 Ω Transmission Baluns
2,8 & 34 Mbits/s 75/120 Ω Transmission Baluns
Standard Baluns Termination Procedure
10
10
11
12
Mini Baluns
13
2-8 Mbits/s 75/120 Ω Transmission Baluns
2,8 & 34 Mbits/s 75/120 Ω Transmission Baluns
34-155Mbits/s high speed Mini Balun
Mini Balun Termination Procedures
13
14
14
15
Dual Baluns
16
2-8 Mbits/s 75/120 Ω Transmission Baluns
34-155Mbits/s high speed Mini Balun
Dual Balun Cables
16
16
17
Balun Panels
18
Ultra High Density Balun Panels
High density balun Panels
Medium Density Balun Panels
Telco Connector Balun Panels
Low Density Balun Panels
18
19
19
20
20
Patch Panels
21
Patch Panel Solutions
Blank Panels
BNC Panels & Accessories
1.6/5.6 Panels & Accessories
Customised Requirements
21
21
21
21
21
Customised Balun Assemblies
22
Quad Balun Assemblies
Connector, Integral Balun Pair (ISDN Baluns)
DB9 to Coaxial Baluns
16 x E1 Transmission Path Interface Module
22
22
23
23
Balun Cables
DDF Solutions
Video Baluns
Broadband Distribution Systems
Notes
Glossary
24
25
26
27
28
31
www.acande.com
page 3
Baluns - Introduction
An unmatched source and load in a transmission system causes poor energy transfer from
one part of the system to the next. Baluns are the ideal solution to this problem as they allow
two systems of different characteristic impedance to each see their ideal load and source
impedance. This avoids losses caused by mismatch and allows full coupling of the transmitted
energy from one part of the system to the next.
A common transmission impedance matching problem is interfacing systems with a 75:
impedance (typical of many coaxial cables) to systems with a 120: impedance (as in many
twisted pair cables). There are many other impedances used in transmission systems.
Many modern transmission systems are designed with twisted pair interfaces as they offer
higher density interfaces, smaller cable sizes and lower cable costs. The incompatibility with
older established 75: systems is overcome with Baluns allowing equipment with different
interfaces to co-exist without penalty.
AC&E is a company that specializes in connectivity and interface solutions. We design and
produce a wide range of Baluns that support transmissions from DC to 1GHz in a variety of
connectivity standards and physical configurations that are intended for many different
applications.
In addition AC&E manufacture baluns in six main housing styles with a wide variety of
coaxial and twisted pair interfaces. Coaxial connector types supported include BNC, 1.6/5.6,
BT43, 1.0/2.3, APT1000, SMB, PAL, F and BPO10 connectors in male (m), female (f) and a
variety attachment styles. Twisted pair terminations include Krone IDC, AC&E’s clamp IDC,
Screw Terminal, Wire Wrap, Pin Header, Telco, D Connectors and RJ45’s.
Reliable long life connections with impedance matching is our business. Our connectivity
and interface solution guarantees your signal integrity.
This document lists the range of AC&E’s catalogue Balun products and is intended as a
selection guide. Its contents are subject to change without notice. Our design team is well
experienced in quickly producing products to solve a special connectivity and interface problem.
Balun Housing
The most common housings for AC&E’s Catalogue Balun products are:x
The Standard Balun which is intended for panel mounting and comes
with a variety coaxial interfaces and has an industry standard Krone
IDC for twisted pair connection. This product is used to house Baluns
for use in the 0 – 50Mhz signal range.
x
The Mini Balun, a fully shielded product which is intended for either
panel or cable mounting, comes with a variety coaxial interfaces and
AC&E’s Clamp IDC for twisted pair termination. This product houses
Baluns for use in the 0 – 250Mhz signal range.
x
The PCB Balun which is intended for use by equipment makers who
need a PCB mounting 75: coaxial interface on their system. The
benefit of this solution is that it incorporates impedance
transformation and isolation within the same connector footprint.
x
The Broadband Balun is a product whose packaging is optimized for
use in impedance matching 50 – 1,000MHz signals for CATV
networks.
B13603010
B04002060
Page 4
www.acande.com
x
x
Dual Baluns. These products provide transformation of a 75:
coaxial Tx/Rx pair to two 120: twisted pair outputs on a single
RJ45 socket. The product is primarily aimed at interfacing T1/E1 to
T3/E3 transmissions.
M1300921R2
Balun Panels. These products house multiple Standard or Mini Baluns for users who require
a high density of Baluns. The convenience and cost saving of a 19” or similar instrument
rack in large and professional systems makes these products a popular choice.
Telecommunications Applications
AC&E’s range of Baluns for telecommunications supports data speeds up to 155Mbit/s and meets or
exceeds all the parameters of the ITU–G.703 specifications. These Baluns comprise of three
Catalogue types:x
x
2–8Mbit/s speed version (for E1/T1 and E2/T2 data streams)
2–8–34Mbit/s speed version (for E1/T1 to E3 data streams)
x
34 to 155Mbit/s, high speed version (for E3 and higher data streams)
Conversion from coax to twisted pair cables enables the use of high density IDC (insulation
displacement connection) modules to be used for distribution frames, increasing the wiring density
by more than 5 times, effectively reducing the space requirement to 1/5 or less. This creates space
within the exchange for the installation of additional lines and facilities.
Australia’s major telecommunication carrier has accomplished the conversion of all their 2 and
8Mbit/s Digital Distribution Frames (DDF) from coaxial to twisted pair cabling using Baluns supplied
by AC&E. This has achieved substantial multi-million dollar savings. It is our understanding that this
carrier wishes to convert all their coaxial system within their exchanges to run on twisted pair cables
for data rates covering 34, 45, 140 and 155Mbit/s, and AC&E is providing the necessary components
for them to do so. AC&E is well acquainted with the technology to help any other telecommunications
organisation considering the advantages of such an exercise.
The maximum distances for twisted pair cables used in conjunction with the Baluns will depend on
the grade of cables being used and the number of twists per unit length. Typical distances on good
quality cables will be 300 metres and 160 metres respectively for 2Mbit/s and 8Mbit/s using the
existing Baluns and 60 metres for 155Mbit/s with the new high speed Baluns.
Benefits in Converting DDF from Coax to Twisted Pair
1.
The space occupied by the DDF is reduced to one fifth, or less
2.
Enables expansion without new buildings, ducting or additional space.
3.
Use of smaller, low cost twisted pair cables enables easier cable routing and management.
4.
Quick and easy termination of twisted pair wires saves material and labour cost.
5.
High reliability of gas tight IDC contacts.
6.
Full solution for migrating from old technology to new 120: structure.
www.acande.com
page 5
Generic Single Balun Part Numbering
AC&E single Baluns identified in this catalogue conform to the part numbering standard
identified on this page. Part numbers not defined generally are customer specific types. This
table is useful for quickly selecting products but please request a data sheet to check all
specifications and user data before purchasing products.
Balun Type - Bxx
B00
B13
B04
B08
Video DC to 8MHz, 75/120Ohm
2, 8Mbit/s, 75/120Ohm
2, 8, 34Mbit/s, 75/120Ohm
High Speed 34 to 155Mbit/s, 75/120Ohm
Coaxial Connector - yyy
1.6/5.6 (m) Snap Coupling
1.6/5.6 (m) Screw Coupling
1.6/5.6 (f)
BNC (m) 75Ohm
BNC (f) 75Ohm
BNC (f) 75Ohm Bulkhead
1.6/5.6 (m) Rt Angle Snap
BNC (m) 75Ohm Rt Angle
APT 1000 (m) Fixed Mtg with Locking Bush
1.0/2.3 (m) Straight Posi-Lock 75Ohm
1.0/2.3 (f) Bulkhead 75Ohm
Type 43 (f) In-line Posi-Lock
Type 43 (m) In-line Fixed Chassis Mtg
Type 43 (m) In-line Floating Chassis Mtg
Type 43 (m) HDC Floating Chassis Mtg
SMB (f) In-line
SMB (f) Rt Angle
001
002
003
008
009
019
025
028
041
043
044
046
048
049
052
078
085
Coax
yyy
Balun
Bxx
IDC
zzz
Generic Balun p/n
Bxx yyy zzz
Twisted Pair Connection - zzz
3 pole IDC (Krone), 0.4 to 0.65mm
Clam IDC for 0.5 to 0.65mm STP or UTP wire
Clamp IDC for 0.24 to 0.40mm STP or UTP wire
Clamp IDC for 0.5 to 0.65mm STP or UTP wire HDC
Clamp IDC for 0.24 to 0.40mm STP or UTP wire HDC
eg.
B04 003 060
B13 019 010
B08 044 065
Balun
Balun
Balun
010
060
065
070
075
2,8,34Mbit/s, 1.6/5.6 (f), Clamp IDC 0.5 to 0.65 wire
2,8Mbit/s, BNC (f) 75Ohm Bulkhead, 3 pole IDC (Krone)
34 to 155Mbit/s, 1.0/2.3 (f) Bulkhead, Clamp IDC 0.3 to 0.4 wire
B04 003 060
B13 019 010
Page 6
B08 044 065
www.acande.com
Generic Balun Panel Part Numbering
Balun Type - Mxx
Video DC to 8MHz, 75/120Ohm
2-8Mbit/s, 75/120Ohm
2-8-34Mbit/s, 75/120Ohm
B00
B13
B04
Generic Balun Panel p/n
Mxx yyy zz pp
Coaxial Connector Type - yyy
1.6/5.6 (f)
BNC (f)
Type 43 (m) In-line
1.0/2.3 (f) Bulkhead
SMB (m) In-line
003
009
049
044
083
Panel Matrix - zz
96 Coax and Baluns to 48 Twisted Pair Connectors
48 Coax and Baluns to 24 Twisted Pair Connectors
32 Coax and Baluns to 16 Twisted Pair Connectors
32 Coax and Baluns to 2 Twisted Pair Connectors
16 Coax and Baluns to 8 Twisted Pair Connectors
2 Coax and Baluns to 1 Twisted Pair Connector
98
44
36
32
18
21
Configuration - pp
RJ45, 1 RU, 19” Rack Black, wired 1245, 2 sided
RJ45, 2 RU, 19” Rack, Black, wired 1245, all connectors one side
Telco connector, 2RU 19” Rack Black, fixed wiring, 2 sided
eg. M13 003 36 R6
www.acande.com
M13
003
36
R6
R1
R6
T1
Balun Panel 2-8Mbit/s, 75/120Ohm,
1.6/5.6 (f) Coaxial Connectors
32 Coaxial Connectors and Baluns to 16 twisted pair connectors
RJ45, 2 RU, 19” Rack, black, wired 1245, all connectors one side
page 7
Electrical Characteristics of 2-8Mbit/s, 75/120: Balun
This AC&E Telecommunication Balun is intended for
2-8Mbit/s
data
transmissions
and
features
the
following performance characteristics:x Exceeds ITU.G.703 performance requirements
x Insertion Loss: < 0.2dB (2Mbit/s); <0.3dB (8Mbit/s)
x Return Loss: -29dB(typ), 2Mbit/s
-21dB(typ), 8Mbit/s
x Isolation > 250V
x Working temp –30 to +75qC
x In Mini, PCB and Standard Balun housing ‘B13’
2Mbit/s pulse performance and
G.703 pulse spec mask
x In Balun Panel housing ‘M13’
x Optimized for E1 and T1 communications
x Other impedances and enclosures on request
Typical return loss and G.703
minimum performance levels for
2 and 8Mbit/s transmissions.
The return loss margin provides
performance reserve against
crushed cables, over bent
cables, and other system
imperfections.
Electrical Characteristics of 2-8-34Mbit/s, 75/120: Balun
This AC&E Telecommunication Balun is intended
for
2-8-34Mbit/s,
75/120: transmissions
and
features the following performance characteristics:x Exceeds ITU-G.703 performance requirements
x Insertion Loss: < 0.3dB (8Mbit/s)
x Return Loss: Conforms to ITU.G.703
x Isolation > 250V
x Working temp –20 to +75qC
x In Mini, PCB and Standard Balun housing ‘B04’
8Mbit/s pulse performance and
G.703 pulse spec mask
x In Balun Panel housing type ‘M04’
x Designed for E1, E2 and E3 Communications
x Other impedances and enclosures on request
Page 8
www.acande.com
34Mbit/s pulse performance
and G.703 pulse spec mask
Typical return loss and G.703
minimum performance levels for
2, 8 and 34Mbit/s
Electrical Characteristics of 34 - 155Mbit/s, 75/120: Balun
The AC&E Telecommunication High Speed Balun is
intended for 34 to 155Mbit/s, 75/120: transmissions. It
features the following performance characteristics:x Exceeds ITU-G.703 performance requirements
x Insertion Loss 860KHz to 52MHz < 0.8dB
50KHz to 240MHz < 1.5dB
x Return Loss 1MHz to 240MHz < -15dB
x Isolation > 250V
x Working temp –30 to +75qC
x In Mini Balun housing type ‘B08’
140Mbit/s pulse performance
and G.703 pulse spec mask
x Designed for E3/T3 to 155Mbit/s data streams
x Other impedances and housing on request
Typical return loss and
ITU-G.703
minimum
performance levels for
34
and
155Mbit/s
transmissions.
www.acande.com
page 9
Standard Baluns
Physical Characteristics
x
Intended for panel mounting and can be supplied with a variety
of Coaxial Connectors BNC, 1.6/5.6, Type43, BPO10 etc
x
Twisted pair termination via 3 pole Krone IDC
x
Available in two speed ranges 2-8Mbit/s and 2-8-34Mbit/s
x
The coaxial side is designed for DDF (1.6/5.6 connectors or
similar) installation and for equipment connection (cable
integral) with either male or female connectors
x
The mechanical endurance of the coaxial connectors is
designed to give in excess of 500 connect/disconnect cycles.
x
On the balanced side, the 120: interface connector is designed
to accept termination of single and multi-strand conductors with
nominal diameters from 0.4mm to 0.65mm.
x
The force required to terminate the IDC is designed to remain
fully operative and intact after 50 connect/reconnect cycles for
Krone IDC Terminals
x
Simple cable anchorage is achievable by passing the cable
through the hollow section under terminal markings.
x
B04025010
3
B13019010
B04001010
B13008010
The diagram shows the circuit symbols of the Balun
with its coaxial and twisted pair connectors and the
polarisation of the transformer. The Standard Balun
has an earth connection taken from the outer coaxial
contact to the twisted pair side and labeled ’E‘. It is
optional to connect the shielding to this earth
connection.
B13 019 010
Drawing
2 and 8Mbit/s 75/120: Transmission Baluns
(Identify by black coloured outer body insulation ring)
Electrical Characteristics and Performance
x Performance exceeds ITU.G.703
x The value of impedance match is 75 r 3: resistive to 120 r 4: resistive, when measured
from 51 to 12,672kHz with the unused end terminated into the respective resistive load.
x The insertion loss from both sides is < 0.2dB for 2Mbit/s and < 0.3dB for 8Mbit service.
x Cross talk between any two baluns mounted on a DDF strip with 15mm centres is better than
-80dB in the frequency range of 0.1MHz to 12MHz.
x Return loss is – 29dB(typ) for 2Mbit/s and –21dB(typ) for 8Mbit/s service
x Transmission losses for cable are excluded.
Page 10
www.acande.com
Black Balun Order Codes
Part No
Description
B04 001 010/N
1.6/5.6 (m) snap to 3 pole Krone IDC
B13 002 010
1.6/5.6 (m) screw to 3 pole Krone IDC
B13 003 010
1.6/5.6 (f) to 3 pole Krone IDC
B04 025 010/N
1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC
B13 008 010
BNC (m) to 3 pole Krone IDC
B04 009 010
BNC (f) to 3 pole Krone IDC
B04 028 010
BNC (m) Rt. angle to 3 pole Krone IDC
B13 019 010
BNC (f) bulkhead to 3 pole Krone IDC
Customer Specified Black Baluns
Part No
Specifier
Description
353/330
Telstra
1.6/5.6 (m) snap to 3 pole Krone IDC
353/644
Telstra
1.6/5.6 (m) screw to 3 pole Krone IDC
353/329
Telstra
1.6/5.6 (f) to 3 pole Krone IDC
353/518
Telstra
1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC
353/693
Telstra
BNC (m) to 3 pole Krone IDC
353/610
Telstra
BNC (m) Rt. angle to 3 pole Krone IDC
2, 8 and 34Mbit/s 75/120: Transmission Baluns
Identifiable by its outer body insulating ring which is coloured white.
Electrical characteristics and performance
x
The value of the impedance match is 75 ± 10: resistive to 120 ± 12: resistive, when
measured at 1 to 17MHz and with the unused end terminated into the respective resistive
load.
x
The insertion loss less than 0.9dB is in the range 0.2MHz to 70MHz from both sides.
x
Cross talk between any two baluns mounted on a DDF strip is better than -60dB with
vertical orientation of IDC connectors in the range of 1MHz to 70MHz
x
Return loss is better than -15dB in the frequency range of 1MHz to 70MHz in both
directions of transmission conforming to ITU-G.703.
x
Transmission losses for cable are excluded
2-8-34Mbit/s Standard Balun Order Codes
Part No
Description
B04 001 010/L
1.6/5.6 (m) snap to 3 pole Krone IDC
B04 002 010/L
1.6/5.6 (m) screw to 3 pole Krone IDC
B04 003 010/L
1.6/5.6 (f) to 3 pole Krone IDC
B04 025 010/L
1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC
B04 008 010/L
BNC (m) to 3 pole Krone IDC
B04 009 010/L
BNC (f) In-line to 3 pole Krone IDC
B04 028 010/L
BNC (m) Rt. angle to 3 pole Krone IDC
B04 019 010/L
BNC (f) bulkhead to 3 pole Krone IDC
Customer Codes for 2-8-34Mbit/s Baluns
Part No
Specifier
Description
353/867
Telstra
1.6/5.6 (m) snap to 3 pole Krone IDC
353/875
Telstra
1.6/5.6 (m) screw to 3 pole Krone IDC
353/566
Telstra
1.6/5.6 (f) to 3 pole Krone IDC
353/873
Telstra
1.6/5.6 (m) Rt. angle snap to 3 pole Krone IDC
353/876
Telstra
BNC (m) to 3 pole Krone IDC
353/874
Telstra
BNC (m) Rt. angle to 3 pole Krone IDC
www.acande.com
page 11
Standard Balun Termination Procedure
1. Mount the balun to the panel (if applicable).
2. Strip the cable sheath to expose the individual twisted pairs (if applicable)
3. Pass the desired twisted pair through the cable restraint hole in the moulding entering at ’A‘
4. Loop the wires back over and into the appropriate slot in the IDC connector.
5. The IDC marked ’A‘ corresponds with the centre contact in the coax connector, ’B‘
corresponds to the outer contact and ‘E’ earth.
6. Terminate the IDC using a Krone terminating tool.
7. Dress the cables as shown in the diagram below, allowing a loop of about 25mm at the cable
entry in case the wires need to be re-terminated.
APPROX. 25mm
TWISTED PAIR ENTERS THE HOLE AT THE
END OF THE CABLE RESTRAINT AND LOOPS
BACK OVER THE BLOCK INTO THE IDC
MULTI PAIR CABLE
Typical 1DME application of Balun replacing coaxial connectors
Part No.
KR6089-2-003-00
TJ1
Description
IDC Connection tool
Standard Balun Termination Jig
(for termination of unmounted 1.6/5.6 only)
TJ1
Page 12
www.acande.com
Mini Balun Series
Mini Baluns are ideal in applications where size and space are
restricted due to their small dimensions. They are intended for panel
or cable mounting and feature AC&E’s clamp IDC termination allowing
installation without special tools.
They are fully shielded and offer EMC compatibility and EMI
compliance as well as excellent high data rate performance. They are
available in three speed ranges, 2-8Mbit/s, 2-8-34Mbit/s or 34 to
155Mbit/s.
B04044060
The Mini Balun is the subject of a number of patent applications.
Mini Baluns offer the following performance features:x Fully shielded
x Three speed ranges, 2-8Mbit/s, 2-8-34Mbit/s or 34 to 155Mbit/s.
x Electrical Characteristics on pages 8 and 9
x EMC and RFI Compliant
x
x
x
Contacts Plated min. 1.25µm Ni + min. 1.25µm Au
Coax Connectors with BeCu spring contacts and Teflon Insulators
Coaxial Connector Insertion cycles > 500
x
x
x
x
IDC Contacts Phosphor Bronze
IDC Insertion Cycles > 20
IDC to suit 0.24 to 0.40mm Cu wire (p/n ends ‘5’) AWG 22-24
IDC to suit 0.50 to 0.65mm Cu wire (p/n ends ‘0’)AWG 26-28
x
x
Body Parts Plated Min. 5µm Ni
Cable anchorage via channeled stress-relief around stuffer cap
B13 019 060
B04003060
B04046060
B04 003 060
Mini Balun 2-8Mbit/s, 75/120: Balun
(Identify by black coloured IDC former)
Order Codes
Part Number
B13 001 060
B13 002 060
B13 003 060
B13 008 060
B13 019 060
B13 043 060
B13 044 060
B13 046 060
B13 048 060
B13 049 060
B13 052 070
B13 078 060
B13 085 060
Description
1.6/5.6 (m) Straight Snap Coupling
1.6/5.6 (m) Straight Screw Coupling
1.6/5.6 (f) Straight Bulkhead
BNC (m) Straight
BNC (f) Straight Bulkhead
1.0/2.3 (m) Straight Posi-lock Coupling
1.0/2.3 (f) Straight Bulkhead
Type 43 (f) Straight Posi-lock Coupling
Type 43 (m) Straight Bulkhead Fixed Mounting
Type 43 (m) Straight Bulkhead Floating Mounting
Type 43 HDC (m) Straight Floating Mounting
SMB (f) In-line Coupling
SMB (f) Rt. Angle Coupling
(0.50 to 0.65mm wire types listed, for 0.24 to 0.40 wire p/n last digit ‘0’ becomes ‘5’)
www.acande.com
page 13
Customer Codes for 2-8Mbit/s Mini Baluns
Part No
NTUM98LA
NTQG41GA
NTUM 98YA
67356-10/196
5105189-0013
5105191-0019
CS73426.08
CS73426.09
Specifier
Nortel
Nortel
Nortel
Marconi
Marconi
Marconi
Nokia
Nokia
Description
Mini Balun Pair, 1.6/5.6 (m) Straight Screw Coupling
Mini Balun Pair , BNC (m) Straight
Mini Balun Pair, Type 43 (m) Str Bulkhead Floating Mounting
Mini Balun, 1.0/2.3 (m) Straight Posi-Lock Coupling
Type 43 (m) Straight Bulkhead Floating Mounting
Type 43 HDC (m) Str Bulkhead Floating Mounting
1.0/2.3 (f) Straight Bulkhead
BNC (M) Straight
Mini Balun 2-8-34Mbit/s, 75/120
Balun
(Identify by fawn coloured IDC former)
Order Codes
Part Number
B04 001 065
B04 002 065
B04 003 065
B04 008 065
B04 019 065
B04 043 065
B04 044 065
B04 046 065
B04 048 065
B04 049 065
B04 052 075
Description
1.6/5.6 (m) Straight Snap Coupling
1.6/5.6 (m) Straight Screw Coupling
1.6/5.6 (f) Straight Bulkhead
BNC (m) Straight
BNC (f) Straight Bulkhead
1.0/2.3 (m) Straight Posi-lock Coupling
1.0/2.3 (f) Straight Bulkhead
43 (f)
(f) Straight
Straight Posi-lock
Posi-lock Coupling
Coupling
Type 43
Type
Type 43 (m) Straight Bulkhead Fixed Mounting
Type 43 (m) Straight Bulkhead Floating Mounting
43 HDC
HDC (m)
(m) Str
Str Bulkhead
Bulkhead Floating
Floating Mounting
Mounting
Type 43
Type
(0.24 to 0.40mm wire types listed, for 0.50 to 0.60
0.65 wire p/n last digit ë5í
'5' becomes
becomes'0')
ë0í)
(0.32
Customer Codes
Part No
848 341 756
848 341 722
848 341 780
848 341 798
848 341 673
848 341 806
848 341 814
848 341 822
848 341 830
848 536 793
848 746 558
848 746 566
Specifier
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Lucent
Description
1.6/5.6 (m) Straight Screw Coupling
1.6/5.6 (f) Straight Bulkhead
BNC (m) Straight
BNC (f) Straight Bulkhead Mounting
APT 1000 (m) StrBulkhead Fixed Mtg with Locking Bush
1.0/2.3 (m) Straight Posi-lock Coupling
1.0/2.3 (f) Straight Bulkhead
Type 43 (f) Straight Posi-lock Coupling
Type 43 (m) Straight Bulkhead Fixed Mounting
1.6/5.6 (f) Monitored Balun U Link 20dB
Type 43 (m) Straight Bulkhead Floating Mounting
Type 43 HDC (m) Straight Bulkhead Floating Mount
High Speed Mini Balun 34 to 155Mbit/s, 75/120 Balun
(Identify by knurled body)
Order Codes
Part No.
B08 002 065
B08 003 065
B08 008 065
B08 019 065
B08 043 065
B08 044 065
B08 046 065
B08 052 075
Description
1.6/5.6 (m) Straight Screw Coupling
1.6/5.6 (f) Straight Bulkhead
BNC (m) Straight
BNC (f) Straight Bulkhead
1.0/2.3 (m) Straight Posi-lock Coupling
1.0/2.3 (f) Straight Bulkhead
Type 43 (f) Straight Posi-lock Coupling
Type 43 (m) HDC Straight Floating Mounting
B08044065
(0.24 to 0.40mm wire types listed, for 0.50 to 0.60
0.65 wire p/n last digit ë5í
'5' becomes
(0.32
becomes'0')
ë0í)
Page 14
www.acande.com
Mini-Balun Termination Procedure
Cable examples
- 060 IDC 26-28AWG Filotex ET2PBB010 (8 pair or similar) or Lucent Technologies 848 317 673.
- 065 IDC 22-24AWG Belden JPMD06AAH0011
1. Dis-assemble the rear end components from the mini-balun.
2. Fit the nut and outer cover onto the cable in that order.
3. Strip the cable jacket to ‘B’ from the end of the cable. Cut the drain
wire and foil ‘A’ from the end of the cable.
4. Flare the foil and fold it and the drain wire back over the sheath.
Fit the grounding ring over the end of the cable.
5. Insert the wires into the holes in the small end of the stuffer cap
marked ’A‘ and ’B‘.
6. The ’A‘ connection corresponds with the polarity of the centre conductor
of the coax. Push the stuffer cap hard against the washer. Spread the
conductors apart towards the sides of the stuffer cap and fit the
conductor ends into the slot in each side of the stuffer cap.
7. Ensure that the end of each conductor is positioned behind the lip
and into the cavity at the end of the slot, as per illustration.
8. Fold the foil and the drain wire back over the outside of the stuffer cap.
Ensure the drain wire ends within the tapered section of stuffer cap.
9. Orient the tongue on the mini-balun to line up with the flat on the
stuffer cap and insert the stuffer cap onto the IDC terminals. Ensure
that the wires are correctly positioned in the slots (Refer to 7 above).
10. Pull the rear outer body forward and align the flat to the tongue in
the Mini-Balun body. Secure the retaining nut finger tight. Lightly
tighten using the spanners recommended.
www.acande.com
page 15
B
A
Dual Balun
This module contains 2 Coaxial Connectors, 2 Baluns and 1 RJ45
socket housed in an insulated enclosure. It is intended to convert an
E1/T1 Channel consisting of 1 Transmit and 1 Receive signal from
75Ω coaxial to 2 x 120Ω twisted pair signals on an RJ45/Cat5 cable.
This module features:Fully shielded Circuitry
Complies with EMC requirements.
Insertion loss: < 0.4dB
Return Loss: < -25dB
Interfaces two coaxial "E1", 2Mbit/s paths into an RJ45 socket
Specified for 2-8Mbit/s use
Other connectors available on request, e.g. SMB
M1300921R2
3
Provides 250V isolation from input to output terminals
Insulated enclosures (BNC 37x37x28mm, Others 31x57x61mm)
Matching impedances 75 to 120 . Others on request.
2-8-34Mbit/s versions available on request
Order Codes
Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω
Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω
Dual Balun, 2x BT43 (m) to RJ45, 2 to 8Mbit/s, 75/120 Ω
Dual Balun, 2x 1.0/2.3 (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω
M1300921R2
M1300321R2
M1304921R2
M1304421R2
Customer Order Codes
408 808 715
A0864597
Lucent
Nortel
Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω
Dual Balun, 2x BNC (f) to RJ45, 2 to 8Mbit/s, 75/120 Ω
High Speed Dual Balun 34 to 155Mbit/s
This module offers two STM1 155Mbit/s paths (also
140Mbit/s, 45Mbit/s or 34Mbit/s) into a single RJ45
socket from coaxial feeders. The module contains 2
Coaxial Connectors, 2 Baluns and 1 RJ45 socket
housed in an insulated enclosure.
The Dual Balun module features:Fully shielded Circuitry
Insertion loss: < 0.8dB
Return Loss: < -15dB from 1MHz to 240MHz and
B08040071
< -18dB from 8.4MHz to 12.6MHz
Cross Talk: < -80dB from 51KHz to 3.072MHz
Pulse Shape: Meets ITU G.703 Mask at 34 and 155Mbit/s
ESD Immunity Tests:
Passed EN 61000-4-2
EMC: Complies with Class B limits of EN 55022 with STP Cable
Provides 1kV isolation from input to output terminals.
Stable over the working temperature of -30ºC to 55ºC
Housed in insulated wall mountable enclosures (31x57x61mm).
Matching impedances 75 to 120Ω . Others on request.
Earthing is available in a number of combinations to suit most applications. As
standard, a capacitor is arranged to connect the grounding of the co-axial to twisted
pair and a zero ohm resistor ties the grounding of both coaxial connectors.
Page 16
www.acande.com
PCB Baluns
Order Codes
No Baluns are available
Description
A selection ofPart
AC&E
housed in PCB mounting
B08
040
072
Dual
Balun,
2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120Ω
right angle coaxial connectors.
B08 040 071
Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120Ω
These products are intended for use by transmission equipment
B08 040 073
Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120Ω
designers who
wish to take advantage
of the space savings that an
B08 040 080
Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120Ω
integrated Connector/Balun provides.
Available in BNC, 1.6/5.6 and BT43 these PCB Baluns feature a
windingBalun
isolationCables
of 250V and are available with a 2-8Mbit/s,
Dual
Transmission Balun core. Other coaxial connectors and
AC&E's
DualonBalun
Cables provide the ideal
impedances
request.
connectivity and interface solution where space
is at a premium as they provide a solution with
or without a patch panel. Factory assembled
Mini
Balun PCB
CableBaluns
assemblies
supplied
to
The AC&E
offer theare
following
performance
features:length as requested.
x Fully shielded
x Balun
Available
in BNC,
1.6/5.6 and BT43 coaxial connectors
Dual
Cables
Feature:
x Common PCB footprint
Compact
panel less
interface solution
x DetaiIed
electrical
characteristics
on pages 8 and 9
Fully shielded interconnect
x 2-8Mbit/s Transmission Balun
Exceeds G.703 specified performance
x 75/120:
transformation
All Miniimpedance
Baluns supported
Supplied
withrugged
cable boots
for additional strain relief
x Small
size and
construction
Catalogue
types
available
from
stock
x Other Coaxial Connectors and
impedances
on request
Cables labeled TX & RX
x 2-8-34Mbit/s Transmission or Video Balun core on request
Order Code (xx=length in metres)
Part Number
S440/xxM
S539/xxM
S441/xxM
S540/xxM
Order Codes
Part
No
S442/xxM
B13
076
035
S541/xxM
B13
045
035
S542/xxM
B13
055
035
S543/xxM
S554/xxM
S557/xxM
www.acande.com
Description
1.6/5.6 (f) x 2 to RJ45 (m) shielded on STP
1.6/5.6 (m) screw x 2 to RJ45 (m) shielded on STP
1.0/2.3 (f) x 2 to RJ45 (m) shielded on STP
1.0/2.3 (m) x 2 to RJ45 (m) shielded on STP
BNC (f) Description
x 2 to RJ45 (m) shielded on STP
PCB
Balun,
(f), 2-8Mbit/s,
75/120:
BNC (m) x 2 to
RJ45BNC
(m) shielded
on STP
PCB
Balun,
1.6/5.6
(f),
2-8Mbit/s,
T43 (f) Posi lock x 2 to RJ45 (m) shielded 75/120:
on STP
BT43to(m),
2-8Mbit/s,
75/120:
T43 (m)PCB
FixedBalun,
mounting
RJ45
(m) shielded
on STP
BT43 (m) x 2 to RJ45 (m) shielded on STP
BT43 (m) HDC x 2 to RJ45 (m) shielded on STP
page 17
Dual
BalunBalun
Panels
This
module
contains
2 Coaxial
Connectors,
Baluns and 1 RJ45
AC&E's
range
of Balun
panels are
intended 2for
socket
housed
in
an
insulated
enclosure.
It
is
intended
to convert an
converting 75Ω coaxial transmissions to 120Ω
balanced
twisted
pair
signals.
They
are
based
on
E1/T1 Channel consisting of 1 Transmit and 1 Receive signal from
AC&E's
Mini
75:
coaxial
to 2Balun
x 120:technology
twisted pairwhich
signalsisonthe
an RJ45/Cat5 cable.
subject of a number of patent applications.
A common application is when new equipment
This
module
features:designed
with
twisted pair interfaces needs to be
B04040072
connected
to
an
established
x Fully shielded
Circuitry coaxial environment.
AC&E's Balun Panels achieve such an interface
x Complies with EMC requirements.
with a minimum of electrical degradation and
x
Insertion
loss: for
< 0.4dB
exceed
ITU-G703
2-8Mbit/s transmissions (28-34Mbit/s
types
available
x Return Loss: < -25dB on request).
Together with matching Patch Panels, Patch
x Interfaces two coaxial ‘E1’, 2Mbit/s paths into an RJ45 socket
Cables, U Links and Connectors AC&E offer a
x
Specified
for 2-8Mbit/s
Complete
Connectivity
and use
Interface Solution.
x Other connectors available on request, e.g. SMB
The Provides
extensive250V
range
of panels
is available
x
isolation
from input
to outputonterminals
19" Rack Mounted Balun Panels
short leadtime and features:x Insulated enclosures (BNC 37x37x28mm, Others 31x57x61mm)
x
x
Matching
impedances
to 120:.
request. limit packing density
Up
to 96 baluns
in 1RU75
panel
heightOthers
offers on
mechanical
versions
on request
52-8-34Mbit/s
density varients
and available
6 configurations
available from stock range
Stocked types include BNC, 1.6/5.6, BT43, SMB and 1.0/2.3 coaxial connectors (others on request)
Order
Codes
Electrical
Characteristics
on page 8
B04 040 072
Dual Balun, 2x BNC (f) to RJ45, 2-8Mbit/s, 75/120:
B04 040 071
Dual Balun, 2x 1.6/5.6 (f) to RJ45, 2-8Mbit/s, 75/120:
Internal
shielding
adacent
channel
< -80dB
B04
040 073gives low Dual
Balun,
2x BT43cross
(m) totalk
RJ45,
2-8Mbit/s, 75/120:
Ultra thin
design (96 balun
45mm,
leaves
more 75/120:
room for cable entry
B04panel
040 080
Dual Balun,
2x others
1.0/2.3 33mm)
(f) to RJ45,
2-8Mbit/s,
Shielded construction gives excellent EMC performance
Reversable panel allows coaxial or RJ45 side to be mounted to the front
Adjustable panel recess gives more cable entry space where required
High
Speed Dual Balun 34 to 155Mbit/s
Zinc sealed, powder coated steel for rigidity and long life
Mounting brackets may be substituted to support other standards
This module offers two STM1 155Mbit/s paths (also
Matching Patch Panels and Blank Panels for a Complete Connectivity and Interface
140Mbit/s, 45Mbit/s or 34Mbit/s) into a single RJ45
Solution
socket from coaxial feeders. The module contains 2
Coaxial Connectors, 2 Baluns and 1 RJ45 socket
UltrainHigh
Density
housed
an insulated
enclosure.Balun Panel 96 Coax to 48 RJ45, 1RU, 75/120Ω
The Dual Balun module features:x
x
x
Fully shielded Circuitry
Insertion loss: < 0.8dB
Return Loss: < -15dB from 1MHz to 240MHz and
B08040071
< -18dB from 8.4MHz to 12.6MHz
x Cross Talk: < -80dB from 51KHz to 3.072MHz
x Pulse Shape: Meets ITU G.703 Mask at 34 and 155Mbit/s
x ESD Immunity Tests:
Passed EN 61000-4-2
x EMC: Complies with Class B limits of EN 55022 with STP Cable
x Provides 1kV isolation from input to output terminals.
Order
codes
x
Stable
over the working temperature of -30qC to 55qC
M13
049
98 R1
BT43 (m)wall
to RJ45,
96x48,enclosures
1RU, 75/120Ω
, 2-8Mbit/s
x Housed
in insulated
mountable
(31x57x61mm).
2-8Mbit/s
M13
044
98
R1
1.0/2.3
(f)
to
RJ45,
96x48,
1RU,
75/120Ω,
x Matching impedances 75 to 120:. Others on request.
,
2-8Mbit/s
RJ45,
96x48,
1RU,
75/120Ω
M13
08398
R1
SMB(m)
to
x Earthing is available in a number of combinations to suit most applications. As
standard, a capacitor is arranged to connect the grounding of the co-axial to twisted
pair and a zero ohm resistor ties the grounding of both coaxial connectors.
Tx
Tx
Tx
Rx
Rx
Rx
Rx
Tx
Tx
Tx
Tx
Rx
Rx
Rx
Rx
Page 18
Tx
www.acande.com
Order Codes
48 Coax to 24 RJ45, 1RU, 75/120:
High Density
Balun Panel
Part No
Description
B08 040 072
B08 040 071
B08 040 073
B08 040 080
Dual Balun, 2x BNC (f) to RJ45, 34 to 155Mbit/s, 75/120:
Dual Balun, 2x 1.6/5.6 (f) to RJ45, 34 to 155Mbit/s, 75/120:
Dual Balun, 2x BT43 (m) to RJ45, 34 to 155Mbit/s, 75/120:
Dual Balun, 2x 1.0/2.3 (f) to RJ45, 34 to 155Mbit/s, 75/120:
Dual Balun Cables
Tx
Tx
Rx
Rx
AC&E’s Dual Balun Cables provide the ideal
connectivity and interface solution where space
Order
is
at a codes
premium as they provide a solution with
M13
009 44 aR1patch
BNC
(f) to RJ45,
48x24,
1RU, 75/120:, 2-8Mbit/s
or without
panel.
Factory
assembled
M13 003
44 R1
(f) to RJ45,
1RU,to75/120:, 2-8Mbit/s
Mini
Balun
Cable1.6/5.6
assemblies
are48x24,
supplied
length
as44
requested.
M13 049
R1
BT43 (m) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
M13 044 44 R1
1.0/2.3 (f) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
Dual Balun Cables Feature:
S440/5M
x Compact panel less interface solution
x Fully shielded interconnect
Medium
Density
Balun
Panel 32 Coax to 16 RJ45, 1RU, 75/120:
x Exceeds
G.703 specified
performance
x All Mini Baluns supported
x Supplied with cable boots for additional strain relief
x Catalogue types available from stock
x Cables labeled TX & RX
Order Code (xx=length in metres)
Tx
Tx
Tx
Part Number
Description
S440/xxM
1.6/5.6 (f) x 2 to RJ45 (m) shielded on STP
S539/xxM
1.6/5.6 (m) screw x 2 to RJ45 (m) shielded on STP
S441/xxM
1.0/2.3 (f) x 2 to RJ45 (m) shielded on STP
Order codes
x 2 to1RU,
RJ4575/120:,
(m) shielded
on STP
M13 009S540/xxM
36 R1
BNC (f) 1.0/2.3
to RJ45,(m)
32x16,
2-8Mbit/s
BNC
(f) x 232x16,
to RJ451RU,
(m) shielded
STP
M13 003S442/xxM
36 R1
1.6/5.6 (f)
to RJ45,
75/120:,on
2-8Mbit/s
BNC
(m) x 32x16,
2 to RJ45
(m)75/120:,
shielded 2-8Mbit/s
on STP
M13 049S541/xxM
36 R1
BT43 (m)
to RJ45,
1RU,
S542/xxM
T43
(f)
Posi
lock
x
2
to
RJ45
(m)
shielded
on STP
M13 044 36 R1
1.0/2.3 (f) to RJ45, 32x16, 1RU, 75/120:, 2-8Mbit/s
S543/xxM
T43 (m) Fixed mounting to RJ45 (m) shielded on STP
Rx
Rx
Rx
Single Sided Balun Panel 32 Coax to 16 RJ45, 2RU, 75/120:
Order codes
M13 009 36 R6
M13 003 36 R6
M13 049 36 R6
M13 044 36 R6
BNC (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
BT43 (m) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
www.acande.com
page 19
Tx
Rx
32 Coax to 2x50way Telco, 1 RU, 75/120:
Broadband
Telco
Connector
Distribution
Balun Panel
System
Home
As modern technology is becoming integral with our
lives, many people require a multi-function outlet in
almost every room in their house.
Tx
Tx
Tx
Tx
Along with the existing Alarm, Radio, Telephone,
analog and ISDN Computer outlets, you can now with
the AC&E Broadband Distribution System, also bring
TV
or Video
Order
Codesto one or every room in your home. This is
achieved
byT1usingBNC
a (f)
balun
cable Telco,
connected
to the 2-8Mbit/s
M13 009 32
to 2x50way
1RU, 75/120:,
M13 003
32 T1wall 1.6/5.6
(f) each
to 2x50way
Cat5e
or Cat6
outlet in
room.Telco, 1RU, 75/120:, 2-8Mbit/s
M13 049
(m) to for
2x50way
Telco, 1RU,
75/120:, 2-8Mbit/s
There
is 32
noT1
longerBT43
a need
duplication
of cables.
M13
044
32
T1
1.0/2.3
(f)
to
2x50way
Telco,
1RU,
75/120:,
With the AC&E Broadband Distribution System, you
can 2-8Mbit/s
now easily change your wall-outlet from a socket for
Tele-work to a TV socket.
Low Density Balun Panel 16 Coax to 8 RJ45, 1RU, 75/120:
Rx
Rx
Rx
Rx
Office
Why install a costly coaxial TV cable into an existing
premises, when many buildings already have many
twisted pair cables installed for varying applications?
Tx
Tx
Using the AC&E Broadband Distribution System, TV
signals can now be distributed economically over
twisted pair cable. Installation of the AC&E Broadband
Distribution System is straight forward as the system is
Order Codes
designed
to fit readily into either a standard 10” or 19”
M13 009 18 R1
BNC (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
equipment racks where many of the twisted pair ends
M13 003 18 R1
1.6/5.6 (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
are already terminated. Simple RJ45 patch cords are
M13 049 18 R1
BT43 (m) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
used
to patch
two systems
together.
The75/120:,
system2-8Mbit/s
M13 044
18 R1 the 1.0/2.3
(f) to RJ45,
16x8, 1RU,
can handle up to Channel 69 (European Standard).
Additionally AC&E Broadband Balun patch cords are
Single
Sided
Balun
Panel
Coax tois8 RJ45, single sided, 2RU, 75/120:
required when
only an
unbalanced
input16facility
available on the TV set (PAL coaxial connector).
Rx
Rx
Order Code
Part No
Description
VDS001
Broadband Distribution System with 4 outlets, 10” panel *
VDS002
Broadband Distribution System with 8 outlets, 10” panel *
VDS003
Broadband Distribution System with 4 outlets, 19” panel
Order Codes
VDS004
Broadband Distribution System with 8 outlets, 19” panel
M13 009 18
R6
BNC (f) to Broadband
RJ45, 1 Side,
2 RU,
75/120:,
2-8Mbit/s
VDPC01/2M
Balun
patch
cord, 2m,
PAL(m) to RJ45 UTP
M13 003 18
R6
1.6/5.6 (f) to
RJ45, 1 Side,
RU, 75/120:,
VDPC02/2M
Broadband
Balun2 patch
cord, 2m2-8Mbit/s
PAL (m) to RJ45 STP
VDSTERM
RJ45
Terminator
M13 049 18
R6
BT43 (m) to
RJ45,
1 Side, 2 RU, 75/120:, 2-8Mbit/s
*
10”
panel
made
according
to
Krone
cabinet
sizes.
Other 10”
sizes on request.
M13 044 18 R6
1.0/2.3 (f) to RJ45, 1Side,
2 RU,
75/120:,
2-8Mbit/s
Page 20
www.acande.com
Patch Panel Solutions
AC&E’s range of matching Patch Panels
complements the AC&E range of Balun panels
thus providing interconnect solution that is
highly
functional
and
professional
in
appearance. Constructed in zinc sealed, black
powder coated steel they are built for long life.
The Baluns, U Links, Through Adaptors and
Patch Cables listed on this page have been
designed with compatibility in mind and are
intended to be used in and on the patch panels
listed here to provide a complete connectivity
and interface solution.
Select your coaxial connectors from AC&E’s
range of BNC, 1.6/5.6, BT43 and 1.0/2.3 listed
on the web for your total requirement.
STU D Y
BE D R O O M
BE D R O O M
Blank Panels
Order Codes - Blank Panels
Part No.
JS1 Blank
JS4 Blank
Description
C o n c e a le d W irin g
Blank Panel, 1 RU, 19”, black powder coated steel
Blank Panel, 2 RU, 19”, black powder coated steel
10” RACK
M O U N TIN G
M O D U LE
BNC Panels & Accessories
LIVIN G A R E A
K ITC H E N
Order Codes - BNC Panels
JS7/40 BNCU
JS3/20 BNCU
BNC panel,
20,N2DRU,
powder
BR O A2DxBA
D ISblack
TR IBU
TIO N coated
SYSTEsteel,
M empty
BNC panel, 1 x 20, 1 RU black powder coated steel, empty
Order Codes - BNC Panel Accessories
Balun
Select
anyNumber
BNC Standard
or Mini
from this catalogue
Specification:
Part
VDS001,
VDS002
A000409
U
Link
BNC
(m)
BNC
(m)
Power Input
5.5 Watt 50 and 60Hz 230V
S267/1M
Cablefemale
BNC (m) - BNC (m) 1m length
Input
Connection Patch
F-type
A000410
BNC (f)-BNC (f) through adaptor (push on), insulated
Output Connection
4 x RJ45 sockets (VDS001), 8 x RJ45 sockets (VDS002)
AC1291
BNC (f)-BNC (f) through adaptor (bayonet), insulated
Frequency Range
47 to 862MHz
Gain and Equalisation Set for +2dB system gain with 30m typical Cat5e cable
1.6/5.6
Panels & 88
Accessories
Size
(2RU) x 254 x 185 (HxWxD)
Order
1.6/5.6 Panels
TypicalCodes
Cable –
Lengths:
JS3/48
1.6/5.6
Panel, 2x24, 1 RU, black powder coated steel, empty, 15mm pitch
Cat.
5e 1656U
40m*
JS3P/48
1656U
1.6/5.6
Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch
Cat. 6
45m*
Order
Codes
- 1.6/5.6
Panel
Accessories
*Distance
depends
on the
input
signal strength and the transmission characteristics of the cable used.
A001705
Balun
A001702/15/1/N
A001716/15/2/N
A001716/15/1/N
A001717/15/2/N
C O AX IA L C A BL E
S250/1M/N
Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f) , uninsulated
Select any 1.6/5.6 Standard or Mini Balun from this catalogue
U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch
U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch
U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch
R J45coupling side TW
ISTE D PA
IR
J45
R O A D B A N DSnap
BROAD BAND
U Link Bmonitor
entry
monitor
(f) 26db R15mm
pitch
A M PL IFIER
W ALL
C AT 5e / 6
W ALL
B A LU N
B A LU N
Patch cable
1.6/5.6
(m)
1.6/5.6
(m),
length
1m
SO C K ET
C A BLE
SO C K ET
SIN G LE C HA N N EL A PPLIC ATIO N
Customised Requirements
Specification
without notice.
This product isPatch
supplied
for evaluation
has yet
undergo
approvals testing.
Should yousubject
have toa change
requirement
for a customized
Panel,
U Link,and
Balun
ortoCable
please
e-mail us at connect@acande.com with your requirement.
www.acande.com
page 21
Customised Balun Assemblies
Balun Panels
Following are examples of customer specific products that we have produced on request to solve
specific
interface
needs.panels
You too
can haveforyour specific needs addressed by AC&E, by
AC&E’s range
of Balun
are intended
specifying
your
own
requirements.
Contact
by phone, fax or web to discuss your requirements.
converting 75: coaxial transmissions to us
120:
balanced twisted pair signals. They are based on
AC&E’s Channel
Mini Balun Balun
technology
which is the
Quad
Assembly
subject
of
a
number
of
patent
applications.
Order Code: B04 040 074
Customer: Nokia
A common application is when new equipment
designed with twisted pair interfaces needs to be
Description:
connected
an established
coaxial environment.
This
Quad to
Channel
Balun assembly
has been developed for a
AC&E’s
Balun
Panels
achieve
such an interface Equipment
major
Worldwide
Telecommunication
with a minimum of electrical
degradation
and
Manufacturer/Solutions
Provider.
The product
features
exceed ITU-G703
for 2-8Mbit/s
miniature
connectors
(4x Type transmissions
SMB) and an(2-RJ45 socket.
8-34Mbit/s
types
request).
This
package
is available
extremelyonsmall
and is capable of handling
Together
with
matching
Patch
Patch
four channels at E1 (2.048Mbit/s)Panels,
or T1 (1.544Mbit/s)
rates
Cables,
U
Links
and
Connectors
AC&E
offer
and has an isolation voltage rating of 1.5KV DC. a
Complete Connectivity and Interface Solution.
B04040074
Features:
The extensive range of panels is available on
19” Rack Mounted Balun Panels
short
leadtime
features:x
The
size is and
small
for the purpose of converting 4 coaxial
transmission paths into one single RJ45 socket and
x packaging
Up to 96 baluns
1RU panel
height
offers mechanical
these infunctions
into
a volume
of 31 x 33limit
x packing density
x 43mm.
5 density varients and 6 configurations available from stock range
x
Various
coaxial
connector
typesand
can
be coaxial connectors (others on request)
x Stockedcombinations
types include of
BNC,
1.6/5.6,
BT43, SMB
1.0/2.3
incorporated into this design such as 1.6/5.6, Type 43,
x BNC,
Electrical
Characteristics
on page 8of connector types can
1.0/2.3
and other variations
x be
Shielded
construction
gives
excellent is
EMC
performance
accommodated (size adjustment
necessary
to suit
size
of
coaxial
connectors)
upon
request.
x Internal shielding gives low adacent channel cross talk < -80dB
x Corporate labeling can be arranged to suit major customer requirements. In addition, for the
x Ultra thin panel design (96 balun 45mm, others 33mm) leaves more room for cable entry
purpose of technician labeling an area for felt pen marking is provided.
x Low
Reversable
panel allows
coaxial
or and
RJ45
side to
be mounted
to the
front
x
losses. Insertion
Loss:
< 0.5dB
Return
Loss:
better than
20dB.
x
x
Adjustable panel recess gives more cable entry space where required
Zinc sealed, powder coated steel for rigidity and long life
x Mounting brackets may be substituted to support
Connector,
Integral Balun Pair
other standards
x Matching
Patch
and Customer:
Blank Panels
for Australia
a Complete Connectivity and Interface
Order
Code: B04
023Panels
024
Telstra
Solution
Description:
Ultra
High
Density
Panel
96 Coax
Connector,
Integral
Balun Pair, Balun
75-120: (for
Ericsson
ISDN to 48 RJ45, 1RU, 75/120:
B04023024
PRA Interface)
Features:
x Allows unbalanced coaxial type 75: equipment to simply connect to 120: shielded twisted
pair. It provides interfacing to two separate circuits (a ’go‘ and ’come‘ path).
x Avoid more costly and space consuming 75: hardware for patching at the distribution frame.
x Minimal losses and distortion - refer ’Black‘ Balun characteristics. (refer page 10).
x Low cost and optimal size form a simple design with minimal component count, being integral
with existing connectors typically used in ISDN Interface Cards on AXE Systems.
x Electrically shielded between adjacent circuit.
Tx
Tx
Tx
Rx
Rx
Rx
Rx
Tx
Tx
Tx
Tx
Rx
Rx
Rx
Rx
Tx
Cross Talk Performance (Isolation):
Order codes
x Adjacent Balun near End Cross Talk is better than 35dB up to 34MHz and better than 28dB up
M13
98 R1
BT43 (m) to RJ45, 96x48, 1RU, 75/120:, 2-8Mbit/s
to049
80MHz.
M13
044
98
R1
(f) to RJ45,
96x48,
1RU, 75/120:,
2-8Mbit/s
x Other electrical1.0/2.3
parameters
- refer
Standard
2-8Mbit/s
Balun in this catalogue.
Page 22
www.acande.com
DB9 to Coaxial Connector
Order
B10 003
054 DB9(m)
48 Coax(f)to 24 Customer:
RJ45, 1RU,Lucent
75/120:
Highcode:
Density
Balun
Panelto 1.6/5.6
B10 048 054 DB9(m) to Type 43 (m) Customer: Lucent
Description:
A simple solution to the problem of converting a
2Mbit/s (E1) signal from twisted pair 120: to
coaxial 75: in one compact adaptor.
This device has shielding compliant with EMC
requirements and transmission performance to
ITU-T G.703 requirements. This is a typical cost
effective solution for transferring a clock signal
from
network to another.
Orderone
codes
Tx
Tx
Rx
Rx
DB9 to Coaxial Baluns
M13 009 44 R1
BNC (f) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
1.6/5.6 (f) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
M13 049 44 R1
BT43 (m) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
x Bit rates of 2 and 8Mbit/s
M13 044 44 R1
1.0/2.3 (f) to RJ45, 48x24, 1RU, 75/120:, 2-8Mbit/s
Features:
M13 003 44 R1
x
x
High speed Bit rates, 34 to 155Mbit/s on request.
Low insertion loss figures together with good return loss performance and meets the mask
performance of ITU-Telecommunication G.703. (refer to mini-balun electrical performance).
x Gives low cross-talk and excellent EMC performance.
32 SMA/B/C,
Coax to 161.0/2.3
RJ45, etc.
1RU, 75/120:
Medium
Balun
Panel
x
Adaptable Density
to other coaxial
connectors.
eg: BNC,
x Designed for Impedance Matching – typically 50 or 75: to 100 or 120 or 150:.
x Cost effective high reliability product with good surge performance ITU-T K17.
16 x E1 Transmission Path Interface Module
Order Code: K125
Customer: Nortel
Tx
Description:
Panel assembly containing 16 x Type 43 male
connectors and having 75/120: Mini Baluns
then
to Male D Sub Connector (44
Orderconnecting
codes
pin).
Rx
Tx
Tx
Tx
Rx
Rx
Rx
M13 009 36 R1
BNC (f) to RJ45, 32x16, 1RU, 75/120:, 2-8Mbit/s
M13 003 36 R1
(f) to RJ45, 32x16, 1RU, 75/120:, 2-8Mbit/s
The assembly was1.6/5.6
designed
to work at 2Mbit/s
M13 049
36 R1
BT43
RJ45, 32x16, 1RU,
and
complying
with(m) to
International
EMC75/120:, 2-8Mbit/s
M13 044 36 R1 It 1.0/2.3
(f) to RJ45,
32x16,
1RU, a75/120:, 2-8Mbit/s
requirements.
was custom
built
to suit
defined volume within a modern UTMS System.
Single
Sided Balun Panel 32 Coax to 16 RJ45, 2RU, 75/120:
Features:
x
x
x
x
Allows for earthing options for Tx and Rx paths.
Identification strip which allows labelling of each
transmission path.
A handle is provided on the assembly to allow it to be installed in a confined space as well as
provision for sealing the assembly within the System so that minimum exposure of the cables
is provided.
The frame is only 155 x 45mm and 75mm deep. Refer to mini-baluns for mechanical and
electrical detail
Order codes
M13 009 36 R6
M13 003 36 R6
M13 049 36 R6
M13 044 36 R6
BNC (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
1.6/5.6 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
BT43 (m) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
1.0/2.3 (f) to RJ45, 32x16, 2RU, 75/120:, 2-8Mbit/s
www.acande.com
page 23
Telco Connector
Balun
Cable Assemblies
Balun Panel 32 Coax to 2x50way Telco, 1 RU, 75/120:
Tx
Tx
Tx
Tx
Rx
Rx
Rx
Rx
Order Codes
M13 009 32 T1
M13 003 32 T1
M13 049 32 T1
M13 044 32 T1
BNC (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
1.6/5.6 (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
BT43 (m) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
1.0/2.3 (f) to 2x50way Telco, 1RU, 75/120:, 2-8Mbit/s
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
Low
Density
Balun
PanelOn16the
Coax
to 8 RJ45,
75/120: of single or multishown on
page 13 of
this handbook.
balanced
side1RU,
a selection
connectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Coaxial Side (with Mini-balun)
Type 43
1.6/5.6
1.0/2.3
BNC
Customised
Cable Types
Recommended for Minibaluns. (CBTP26301)
UTP, Cat.5e or Cat.6
STP, Cat 5
Customised
Tx
Twisted Pair Side
RJ45 Plug
(shielded or non-shielded)
DB9 to 37 for plug or socket
Bantam Plugs
Customised
Rx
Tx
Rx
Optional cable labels and cable stress relief attachments are available
Order Codes
Examples:
M13 009 18 R1
BNC (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
M13 003 18 R1
1.6/5.6 (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
PtM13
No 049
‘S281/3M’
065 16x8,
to 1RU, 75/120:,
Pt2-8Mbit/s
No ‘S440/1M’ using 2 x B04 003 065 to
18 R1 using
BT43B04
(m) 001
to RJ45,
Krone 4P on CBTP26301
RJ45 on STP Cat 5
M13 044 18 R1
1.0/2.3 (f) to RJ45, 16x8, 1RU, 75/120:, 2-8Mbit/s
Single Sided Balun Panel 16 Coax to 8 RJ45, single sided, 2RU, 75/120:
Order Codes
M13 009 18 R6
M13 003 18 R6
M13 049 18 R6
M13 044 18 R6
BNC (f) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
1.6/5.6 (f) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
BT43 (m) to RJ45, 1 Side, 2 RU, 75/120:, 2-8Mbit/s
1.0/2.3 (f) to RJ45, 1Side, 2 RU, 75/120:, 2-8Mbit/s
Page 24
www.acande.com
PatchSolutions
DDF
Panel Solutions
AC&E’s
range of matching
Patch
DDF Temporary
Patching
UnitPanels
complements
the
AC&E
range
of
Balun
panels 2 x 510 Ohm
PART No LSS PP2
4 x Port
thus
providing
interconnect
solution
that
PART No LSS PP3
4 x Port (SI353/970) is 2 x 1K2 Ohm
highly
functional
and
professional
in
appearance. Constructed in zinc sealed, black
powder coated steel they are built for long life.
The Baluns, U Links, Through Adaptors and
WITH OPTIONAL PATCH LEADS:
Patch Cables listed on this page have been
4 Pole to 4 Pole Krone, lead 5m
designed with compatibility in mind and are
length. (S308/..M)
intended to be used in and on the patch panels
2 Pole to 2 Pole Krone, lead 30cm
listed here to provide a complete connectivity
length. (S332/..M)
and interface solution.
Select your coaxial connectors from AC&E’s
range of BNC, 1.6/5.6, BT43 and
1.0/2.3 listed
LSS993
on the web for your total requirement.
Description:
Twisted Pair
Frames (Digital Distribution Frame) are common in Telephone & Data Exchanges,
Blank
Panels
particularly where Krone IDC Block (modules) are used. For DDF’s using 2 and 8Mbit/s services
there
often an
emergency
need to deploy patching units at strategic positions on the frame.
OrderisCodes
- Blank
Panels
Part No.
Description
This
unit allows theBlank
insertion
on the
frame
where
JS1 Blank
Panel,anywhere
1 RU, 19”, black
powder
coated
steellocalised patching is required.
Having
placed
the
unit
at
the
most
appropriate
position
on
the
frame, looping in and out of the
JS4 Blank
Blank Panel, 2 RU, 19”, black powder coated steel
unit is simple and live traffic can be readily patched through it. Monitor positions are immediately
set-up providing low risk to the main data flow (26dB or 20dB attenuation). A test access is
provided as well. Each of these units has a four circuit configuration installed. A ‘Hitless’ data
BNC
Panels & Accessories
flow situation is then provided.
S267/1M
Order
Codes
- BNCleads
Panels
A range
of patch
are available for use with the unit, refer to AC&E for Technical
JS7/40 BNCU
BNC panel, 2 x 20, 2 RU, black powder coated steel, empty
information.
JS3/20 BNCU
BNC panel, 1 x 20, 1 RU black powder coated steel, empty
The unit features a standard Krone Block 8 position (or 10 position on request). The unit looks
Order Codes - BNC Panel Accessories
like a standard Block but has the necessary attenuators and wiring on the unit, which can be
Balun
Select any BNC Standard or Mini from this catalogue
slotted
into an emptyUposition
on the frame without interfering with the other Blocks.
A000409
A000409
Link BNC (m) - BNC (m)
S267/1M
Patch Cable BNC (m) - BNC (m) 1m length
Features:
A000410
BNC (f)-BNC (f) through adaptor (push on), insulated
xAC1291
26dB or 20dB Isolation
Resistor
to avoid
interruption
riskinsulated
to data traffic (Hitless).
BNC (f)-BNC
(f) through
adaptor
(bayonet),
x Connection between the Test Point and Patch Point.
x Cross-Over at Patch position (allows the same cross patch cords for both normal and patch
positions).
1.6/5.6
Panels & Accessories
A001705
x Use of 4 Pole polarised Krone plugs, which can prevent the plugs from causing inversion
connection.
Order Codes – 1.6/5.6 Panels
xJS3/48
Minimises
cord Panel,
congestion
the
DDF
(by placing
these
units15mm
in the
appropriate
1656U patch1.6/5.6
2x24, 1on
RU,
black
powder
coated steel,
empty,
pitch
position
on
the
frame).
JS3P/48 1656U
1.6/5.6 Panel, 2x24, 1 RU, grey fibre reinforced plastic, empty, 15mm pitch
Circuit
diagram
of one module shown; there are 4 modules in one unit.
Order Codes - 1.6/5.6
Panel
Accessories
A001705
Balun
A001702/15/1/N
A001716/15/2/N
A001716/15/1/N
A001717/15/2/N
S250/1M/N
Through Adaptor 1.6/5.6 (f) to 1.6/5.6 (f) , uninsulated
Select any 1.6/5.6 Standard or Mini Balun from this catalogue
U Link 1.6/5.6 (m) - 1.6/5.6 (m) screw coupling, 15mm pitch
U Link monitor Snap coupling rear entry monitor (f) 26db 15mm pitch
U Link monitor Screw coupling rear entry monitor (f) 26db 15mm pitch
U Link monitor Snap coupling side entry monitor (f) 26db 15mm pitch
Patch cable 1.6/5.6 (m) - 1.6/5.6 (m), length 1m
Customized Requirements
Should you have a requirement for a customized Patch Panel, U Link, Balun or Cable please
e-mail us at connect@acande.com with your requirement.
www.acande.com
page 25
Customised
Video
BalunsBalun Assemblies
A selectionare
Following
ofexamples
analogue ofBaluns
customer
are specific
availableproducts
that arethat
designed
we have
forproduced on request to solve
specific
needs.composite
You too video
can have
your
specific
use with interface
DC to 6.5Mhz
signals.
Such
signalsneeds
are addressed by AC&E, by
specifying your own requirements. Contact us by phone, fax or web to discuss your requirements.
typically found originating from consumer and professional video
equipment.
Quad Channel Balun Assembly
Coupling signals from remote Video Cameras to recorders, display
Order Code: B04 040 074
Customer: Nokia
B00019010
systems and monitors in broadcasting, surveillance and security
Description:are the most common uses.
applications
This
Quad
Channel
Balun
assembly
has been
for a to be
AC&E
Video
Baluns
allow
long lengths
of developed
coaxial cable
major
Worldwide
Telecommunication
Equipment
replaced with lower cost twisted pair cable. They also allow the use
Manufacturer/Solutions Provider. The product features
of existingconnectors
twisted pair(4x
infrastructure
cable and
miniature
Type SMB)such
and as
an telephone
RJ45 socket.
B00008010
This
package
is
extremely
small
and
is
capable
of
handling
Cat 5 computer networking cables.
four channels at E1 (2.048Mbit/s) or T1 (1.544Mbit/s) rates
and has an isolation voltage rating of 1.5KV DC.
The AC&E Video Baluns offer the following performance features:x Available in Standard and Mini Balun Enclosures
Features:
x No power or batteries
x The size is small for the purpose of converting 4 coaxial
x IEC Standard
connection
transmission
paths BNC
into coaxial
one single
RJ45 socket and
x IDC twisted
pair termination
strainof
relief
packaging
these functions
into awith
volume
31 x 33 x
43mm.
x 75/120: transformation
x Various combinations of coaxial connector types can be
x Small size and rugged construction
incorporated into this design such as 1.6/5.6, Type 43,
x 1.0/2.3
Minimaland
Lossother
distortion
and reflection
per unit
BNC,
variations
of connector
types can
bex accommodated
(sizeand
adjustment
is necessary
Other Connectors
impedances
on requestto suit
size of coaxial connectors) upon request.
x Panel solutions also available
x Corporate labeling can be arranged to suit major customer requirements. In addition, for the
purpose of technician labeling an area for felt pen marking is provided.
x Low losses. Insertion Loss: < 0.5dB and Return Loss: better than 20dB.
Electrical Performance
x
Frequency Range:
DC to 8MHz
Connector,
Integral Balun
x Drive distance:
100mPair
recommended max. Twisted pair
Orderx Code:
B04 023
024
Customer:
Telstra
Australia
Insertion
Loss
(Typ): Telephone
cable
0.5dB
(1m); 3dB (100m)
Part No.
Description
B00 008 065
000000000
Video Mini Balun, Analogue BNC (m) to AC&E clamp IDC, 75/120:
Description:
B00 008 010
Video Balun, Analogue, BNC (m) to Krone IDC, 75/120:
Connector, Integral Balun Pair, 75-120: (for Ericsson ISDN
B00 019 010
Video Balun, Analogue, BNC (f) to Krone IDC, 75/120:
PRA Interface)
Features:
x Allows unbalanced coaxial type 75: equipment to simply connect to 120: shielded twisted
pair. It provides interfacing to two separate circuits (a ’go‘ and ’come‘ path).
x Avoid more costly and space consuming 75: hardware for patching at the distribution frame.
x Minimal losses and distortion - refer ’Black‘ Balun characteristics. (refer page 10).
x Low cost and optimal size form a simple design with minimal component count, being integral
with existing connectors typically used in ISDN Interface Cards on AXE Systems.
x Electrically shielded between adjacent circuit.
Cross Talk Performance (Isolation):
x Adjacent Balun near End Cross Talk is better than 70dB up to 34MHz and better than 50dB up
to 80MHz.
x Other electrical parameters - refer Standard 2-8Mbit/s Balun in this catalogue.
Insertion Loss B00 019 010
Page 26
Return Loss B00 019 010
www.acande.com
new Active splitter
unit
deviceCable
has shielding
compliant
with EMCvideo subMost This
Structured
Systems have
a broadband
requirements
and will
transmission
performance
to
system.
This sub-system
use components
that are separate
from
ITU-T G.703
requirements.
This including
is a typical
cost cable and
the remaining
Structured
Cable System
coaxial
effective
solution for transferring a clock signal
dedicated
outlets.
DB9 to Caxial Baluns
from one network to another.
Coaxial cable is the traditional transmission line for video, however
its useFeatures:
in Structured Cabling Systems means that there must be
dedicated outlets for the video system. The result is a non-flexible
Bit rates
2 and
8Mbit/s
video x
solution.
As of
one
of the
selling points of Structured Cabling
Systems
flexibility
believed
a more flexible
video system
x isHigh
speedAC&E
Bit rates,
34 to 155Mbit/s
on request.
shouldxbe developed.
Low insertion loss figures together with good return loss performance and meets the mask
performance of ITU-Telecommunication G.703. (refer to mini-balun electrical performance).
Imagine
having
ancross-talk
outlet at and
eachexcellent
corner of
the performance.
room that can
x Gives
low
EMC
provide
Telephone,
Internet
or
Video
by
simply
moving
a patch 1.0/2.3 etc.
x Adaptable to other coaxial connectors. eg: BNC, SMA/B/C,
lead
at
your
patch
panel.
x Designed for Impedance Matching – typically 50 or 75: to 100 or 120 or 150:.
Picture
VDCP05 Fly lead
x Cost effective high reliability product with good surge performance
ITU-TofK17.
This is the goal AC&E have set out to achieve. We have designed a
video sub-system that utilises the exact same cables and outlets as
the remainder of your Structured Cable System. BVD.
16 x E1 Transmission Path Interface Module
Order
Code: K125 Video Distribution
Customer:
Nortel
BVD is
a Broadband
system
designed and
manufactured by AC&E in Australia. It is a truly flexible network. Any
Description:
data outlet
supplied by Cat5e, Cat6 or Cat7 cable can also be a
Panel assembly containing 16 x Type 43 male
video outlet.
connectors and having 75/120: Mini Baluns
then connecting
to Male
Sub Connector
(44 including our
By incorporating
high quality
RF D
distribution
techniques
provenpin).
balun designs, AC&E have made distribution of broadband
signals through Cat5e and Cat6 UTP cables possible. Removing the
The assembly
was designed
to work
at 2Mbit/s
requirement
to install coaxial
cable and
dedicated
outlets.
and complying with International EMC
It was
custom built
suit provides
a
Alongrequirements.
with increased
flexibility,
BVD toalso
cost
defined
volume
within
a
modern
UTMS
System.
advantages by offering a one cable, one outlet solution for all
services.
K125
BVD consists of both active and passive modules. Passive modules
Features:
allow for
the provision of a customer-specified amplifier. A return
Allows depending
for earthingon
options
for Tx
and Rxselection.
paths. The 8
path isx available
external
amplifier
x Identification
which
allows
labelling
of each
way active
module has astrip
sloped
output
stage
designed
to meet the
transmission
requirements
of differing path.
cable lengths inherent in all installations.
x A handle is provided on the assembly to allow it to be installed in a confined space as well as
provision
for sealing AC&E
the assembly
within theenable
System
so that minimum exposure of the cables
Special Fly-leads,
incorporating
balun technology
BVD
provided.
to plug into is
the
standard coaxial connection on any TV.
x The frame is only 155 x 45mm and 75mm deep. Refer to mini-baluns for mechanical and
For more information
on the BVD range please contact your AC&E
electrical detail
representative.
www.acande.com
page 27
broadband distribution systems
DB9technology
to Coaxial
Connector
As modern
becomes
more integral with our lives, many
Order
code:
B10
003
054in every
DB9(m)
to of
1.6/5.6
(f)
Customer: Lucent
people require a multi-function
outlet
room
their home.
B10 048 054 DB9(m) to Type 43 (m) Customer: Lucent
For this reason Structured Cable Systems are one of the fastest
Description:
growing
segments of construction industries, globally. They are sold
A simple
solution
to theagainst
problem
of requirements,
converting a enabling
to customers
as future
proofing
data
2Mbit/s (E1)
twisted
pair using
120:patch
to panels
home automation
andsignal
offeringfrom
greater
flexibility,
Picture of
coaxial
75: in services
one compact
adaptor.
to distribute
different
to each
data outlet.
notes
Balun Cable Assemblies
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
shown on page 13 of this handbook. On the balanced side a selection of single or multiconnectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Coaxial Side (with Mini-balun)
Type 43
1.6/5.6
1.0/2.3
BNC
Customised
Cable Types
Recommended for Minibaluns. (CBTP26301)
UTP, Cat.5e or Cat.6
STP, Cat 5
Customised
Twisted Pair Side
RJ45 Plug
(shielded or non-shielded)
DB9 to 37 for plug or socket
Bantam Plugs
Customised
Optional cable labels and cable stress relief attachments are available
Examples:
Pt No ‘S281/3M’ using B04 001 065 to
Krone 4P on CBTP26301
S281/3M
Pt No ‘S440/1M’ using 2 x B04 003 065 to
RJ45 on STP Cat 5
S440/1M
Page 28
www.acande.com
notes
www.acande.com
page 29
notes
Balun Cable Assemblies
Description:
A range of Balun Cable Assemblies are available with your selection of connector types at either
ends. Nominal Impedance ratios of 75 to 120: and bit rates are selectable from the Mini-baluns
shown on page 13 of this handbook. On the balanced side a selection of single or multiconnectors are available with various forms of mounting and/or shielding. The cable selection is
arranged in Characteristic Impedances and/or shielding cost benefits.
Coaxial Side (with Mini-balun)
Type 43
1.6/5.6
1.0/2.3
BNC
Customised
Cable Types
Recommended for Minibaluns. (CBTP26301)
UTP, Cat.5e or Cat.6
STP, Cat 5
Customised
Twisted Pair Side
RJ45 Plug
(shielded or non-shielded)
DB9 to 37 for plug or socket
Bantam Plugs
Customised
Optional cable labels and cable stress relief attachments are available
Examples:
Pt No ‘S281/3M’ using B04 001 065 to
Krone 4P on CBTP26301
Page 30
Pt No ‘S440/1M’ using 2 x B04 003 065 to
RJ45 on STP Cat 5
www.acande.com
Glossary of Terms
Insulation Displacement Connection.
ITU-G.703
International Telecommunication Union – standard for Data Transmission between stations
1RU
1 Rack Unit height. 44mm height for Panels to fit into a rack cavity of 45mm
ISO 9001:2000
Quality Management System requirements for manufacturing, warehousing and design
DDF
Digital Distribution Frame
RFI/EMC
Radio Frequency Interference/Electromagnetic Compatibility
Krone
Krone a manufacturer of IDC connectors
PAL Connector
recognised connector used in the TV Industry.
Cat.5e and Cat.6 Two types of cable used extensively for computer networking.
RJ45
A type of modular plug and socket used with the above cables
1.6/5.6, 1.0/2.3
Type 43, SMB,
BNC
Common Coaxial connector types used in the Telecommunication Industry.
ESD
Electro-Static Discharge
ITU: K17
recognised pulse surge test (type test)
ISDN
Integrated Systems Digital Network
AXE
A type of Ericsson Switching System
ETSI
European Rack System-specification
Telco
a type of multi-terminal connector
D9, D15,
D25, D37
a type of multi terminal connector
UTMS
a form of Mobile Telephone System (Cell phone System)
Telecommunication Data Bit Rate Names:
E1
2.048Mbit/s
E2
8.448Mbit/s
E2 = 4 x E1
E3
34.368Mbit/s
E3 = 4 x E2
E4
139.264Mbit/s
E4 = 4 x E3
T1
1.544Mbit/s
T2
6.312Mbit/s
T2 = 4 x T1
T3
44.736Mbit/s
T3 = 7 x T2
General Conditions
AC&E reserves the right to change product specifications and availability without notice.
www.acande.com
page 31