Copper - Carlton Bates
15.1
Commercial Networking: Copper
Table of Contents
Commercial Networking — Copper
Introduction
Belden IBDN System 10GX
GigaBIX Multi System
BIX Cross-Connect System
110 Cross-Connect System
Labels
Patch Panels
Workstation Outlets
15.2-15.5
15.6–15.8
15.9–15.12
15.13–15.17
15.18–15.20
15.21
15.22–15.24
15.25–15.40
Modular Cords
Network Connectivity Products
Line Protection and Bonding & Grounding
Certified System Cables
Unshielded Twisted Pairs (UTP) Cables
Shielded Twisted Pairs (ScTP) Cables
Special Application Cables
15.41-15.43
15.44
15.45
15.46–15.51
15.46–15.66
15.67–15.69
15.70–15.82
15
Please refer to “Terms of Use of Master Catalog” on page 22.22
Page No.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.2
Introduction
Belden IBDN Networking
Components and Systems
Overview
Each of the copper cabling components
depicted on the following pages is vital to
the overall performance of the network, but
to achieve optimum network performance
you should consider Belden IBDN end-toend structured cabling systems.
Belden IBDN Copper Structured Cabling
Systems are recognized the world over for
their high quality since they are the result
of both Belden’s exceptional design and
manufacturing expertise and the system’s
ability to outperform the standards.
The Revolutionary Belden
IBDN System 10GX
(Cat. 6a | 10 Gb/s | 625 MHz)
What differentiates our 10GX System from
other 10 Gigabit Ethernet offerings? The
Belden IBDN System 10GX is not an
improved or boosted Category 6 system,
but a revolutionary innovation designed
around a series of dynamic enabling
technologies. Because the 10GX System
solves two major performance issues:
(1) a reduction in Alien crosstalk to about
15 dB, or 30 times lower than the Alien
NEXT for 1000BASE-T at a distance of
100 meters, and (2) the System’s ability
to control Insertion Loss, Return Loss,
NEXT, PSNEXT, Alien PSNEXT, ELFEXT,
PSELFEXT and Alien PSFEXT characteristics during high frequency operation —
it not only meets the high speed, high
bandwidth demands of today’s networks,
but this advanced solution is ready to meet
the challenges of the networks of tomorrow.
System 10GX PerformanceEnabling Technologies
The performance of each critical component
of the 10GX solution has been optimized
through use of the following performanceenabling technologies:
The System: Workstation through Hub
■
The system’s cable is based upon an
innovative SpiralFleX™ design that serves
to reduce Alien crosstalk by randomizing
the distance between the cables
■
A patent-pending IDC design and patch
panel circuit layout called MatriX IDC™
technology is utilized to substantially
eliminate the issue of Alien crosstalk
between the system’s modules
■
X-Bar™ technology: The X-Bar is a
control device that enables the accurate
positioning of each UTP pair before the
pair is terminated on the 10GX Module’s
IDC pins
■
A patent-pending FleXPoint PCB
(printed circuit board) is used within
the module housing to position the
compensation circuitry directly at the
plug’s point of contact. Instant compensation delivers excellent crosstalk
performance up to 625 MHz!
10GX Cable Design
Improves Alien Crosstalk
The major technical challenge for traditional
UTP cables resides with the electromagnetic
coupling between a cable and its neighboring
cables. This coupling is typically enhanced
by the fact that all the cable pairs have the
same twisting lay and
10GX Cable
therefore have the
Design
same resonance
frequencies.
Belden’s use of
SpiralFleX technology introduces
randomization in the
cable in two ways:
(1) it induces with neighboring cables — to
accomplish this, a filler is twisted around
the four cable pairs — and, (2) to create
additional randomization along the full length
of the cable, a unique internal cross-web is
incorporated into the cable design.
Since these features both increase and
randomize the distance between a cable
and its neighboring cables, both the ANEXT
coupling and RL channel characteristics of
the cable are improved. In fact, 10GX Cables
were tested in a worst-case scenario —
a six-around-one cable environment —
and still exhibited performance well over
proposed standards. In addition, this
unique 10GX Cable design is more flexible
and installer-friendly than other 10G cables.
Statistically Controlled
Modular Cord Manufacturing
To achieve consistent high performance,
Belden uses a statistical process control
methodology in its modular cord
manufacturing process. This assures
perfect tuning between the module and the
modular cord and offers improved channel
performance. The design of the 10GX
Modular Cord is also based upon a patentpending plug management design that
controls dNEXT and delivers extended
channel performance.
10GX IDC Design
Cancels Out Alien Crosstalk
The IDC is one of the
Traditional Technology
most sensitive areas for
Alien crosstalk management.
In traditional designs, all
of the IDC contacts are
aligned so they become
perfect antennas, allowing
adjacent pairs to both emit
and receive noise.
Belden’s patent-pending
design, called MatriX IDC
technology, positions each
MatriX IDC Technology
IDC at 90 degrees to its
neighbor — effectively canceling out
ANEXT by 15 dB as compared with
traditional technology!
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.3
Introduction
(continued)
Traditional jack designs are performance
handicapped at high frequencies because
of an inherent crosstalk in the plug that
cannot be fully compensated for by the
jack. This crosstalk
occurs because the
compensation
circuitry is located
at some physical
distance from the
source of the noise,
which is at the plug
interface. Even
a very small physical
FleXPoint PCB
distance can have a
Technology
major impact at high
frequencies.
The 10GX Modules feature FleXPoint PCB
technology. This technology incorporates
the use of a flexible PCB that allows the
compensation circuitry to be located
directly at the point of the plug contact.
This reduces the delay between the
source of the crosstalk in the plug and
the crosstalk cancellation circuitry on the
PCB. As a result the crosstalk noise at
high frequencies is dramatically reduced
for outstanding channel performance
to 625 MHz!
Error-Free Termination Practices —
Installable Performance®
Since structured cabling systems for
Category 6 and beyond are extremely
sensitive to installation practices, the 10GX
System mitigates and simplifies installation
issues to ensure overall 10G System
performance. To ensure
optimum termination of
the cable to the module,
a new patent-pending
technology called the
X-Bar was developed.
The X-Bar is a plastic
device that affixes to
the module to ensure
FleXPoint PCB
that each UTP pair is
Technology
consistently positioned
for termination on the
10GX Module’s IDC pins. The X-Bar also
controls the amount of unjacketed cable,
plus it maintains the conductor twist lays
during installation to prevent untwisting.
With this consistent termination feature, the
superior NEXT and ANEXT performance
achieved through use of the system’s
innovative component designs will be
maintained and remain stable throughout
the installation process. We call this
after-installation assurance Installable
Performance.
The 10GX Patch Panel
With 10GX Modules
Alien crosstalk control within a patch panel
is critical to the success of the system. The
high density environment of a patch panel
can be subjected to crippling amounts of
Alien crosstalk. The unique design of the
10GX Module’s IDC, and its ability to cancel
the “antenna” effect between modules
eliminates the Alien crosstalk issue. Because
superior ANEXT performance is assured by
the module-related technologies, this allows
the patch panel ports to be in line. There is
no need to compromise on density, and
labeling and cable management features
are greatly improved. In fact, the module
technology is so powerful, Belden is the
only manufacturer to be able to offer an
ultra high-density solution with 48 ports in
a 1U space!
Belden IBDN Category 5e/
Enhanced Category 6
Components and Systems
Belden IBDN Cat. 5e, Cat. 6 and Beyond
Cat6® Systems can be designed and
installed using either Bonded-Pair UTP
cables or nonbonded-pair UTP cables.
Both types of cable offer performance well
beyond the standards. Bonded-Pair UTP
cables — DataTwist® 350, MediaTwist® and
DataTwist 600e — feature a patented
design that bonds the individual insulated
conductors of each pair along the full length
of the cable. This bonded construction
delivers Installable Performance. That is,
Bonded-Pair cables are consistent in the
distance between the conductors and in the
amount of twist, throughout the installation
process, so they deliver the same, superior
electrical performance both before and
after the cable’s installation.
Our nonbonded-pair family of cables
include GigaFlex® 1200, 2400 and 4800LX
cables. These cables incorporate a
patented design which provides complete
quality control during the manufacturing
process. This allows us to provide high
quality cables that consistently offer
improved channel performance and large
margins over the standards. These cables
will provide the capacity and performance to
maximize your overall network performance.
Belden IBDN punch-down GigaFlex Modules
are based on a patented Encapsulated
Lead Frame technology that ensures longterm reliability, as well as extremely stable
transmission performance. Lead frame
technology is inherently more reliable than
traditional connector technologies as it
uses a single, uninterrupted copper contact
path through the connector. The design of
the GigaFlex Module allows signals to pass
virtually unchanged through the connector,
providing greater system performance.
GigaBIX® Distribution Connectors, featuring
Belden’s BIX Technology, are a uniquely
designed solution centered around an
extremely compact connector equipped
with double-sided Insulation Displacement
Connection (IDC) clips. The benefit of this
unique design is a considerable reduction
in the space that would be required by
conventional connecting systems of the
same pair count. The density of BIX
technology is second to none, allowing up
to three hundred pairs to be terminated in a
very small area — a real space saver,
especially in today’s office environment
where real estate is at a premium.
Belden IBDN System 1200
(Cat. 5e | 1.2 Gb/s | 160 MHz)
If your business is riding the current wave
of growth and expansion, you may be
considering new ways of doing business
and a new or upgraded IT system to
support these new strategies. This is the
ideal time to plan and implement a new
cabling system or to upgrade your existing
infrastructure.
This Category 5e system was developed
to support high-speed network applications
such as Gigabit Ethernet and provides clear
bandwidth up to 160 MHz; an increase of
60% over the Cat. 5e standard of 100 MHz.
Standards organizations such as TIA/EIA
and IEEE now recommend Category 5e
cabling systems for all new cabling
installations.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
10GX Module Eliminates
Signal Degradation
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.4
Introduction
(continued)
Belden IBDN System 2400
(Cat. 6 | 2.4 Gb/s | 250 MHz)
If leading-edge communication systems are
an element of your competitive strategy and
if you consider information technology as
one of the drivers of your bottom line, you
should consider the speed, reliability and
performance advantages of this system.
This Category 6 system meets or exceeds
all requirements of the TIA/EIA Category 6
standard specifications and delivers
250 MHz bandwidth, a 25% increase over
the 200 MHz bandwidth of typical Category 6
compliant channels. The Belden IBDN System
2400 provides the performance, throughput
and reliability necessary to keep your critical
applications operating at peak performance.
Belden IBDN System 4800LX
(Beyond Cat. 6 | 4.8 Gb/s | 300 MHz)
This enhanced Category 6 system was
conceived to support the most demanding,
ultra-high speed and multi-Gigabit protocols,
providing blistering performance.
The Belden IBDN System 4800LX
is the industry’s first 300 MHz system,
far exceeding all TIA/EIA Category 6
specifications.
If every bit of information that your
company processes is mission critical, you
need the performance and reliability that is
built into the Belden IBDN System 4800LX.
Belden IBDN Copper Systems: Primary Selection of Components
Solutions
Available
Channel
Bandwidth
Guaranteed
Data Rate
Belden IBDN System 1200
160 MHz
1.2 Gb/s
PowerSum
UTP Channel
STD Compliance
Cat. 5e*
TIA/EIA
ISO/IEC
IEEE Gigabit
Backbone Cable †
Telecom Room
4-Pair Cables
Cross-Connect
Hardware
DataTwist® 350 1700 (CMR)
DataTwist 350 1701 (CMP)
DataTwist 350 1701 (CMP-50)
GigaFlex® 1212 (CMR)
GigaFlex 1213 (CMP)
GigaFlex 1224 (LSOH)
GigaBIX® Cross-Connect System
PS5E BIX Patch Panel
PS5E HD-BIX Patch Panel
PS5E HD-110 Patch Panel
Flex Patch Panel/EZ-MDVO PS5E Module
Flex Patch Panel/GigaFlex PS5E Module
110 Cross-Connect System
Belden IBDN System 2400
250 MHz
2.4 Gb/s
Cat. 6**
PowerSum
TIA/EIA
ISO/IEC
IEEE Gigabit
Belden IBDN System 4800LX
300 MHz
4.8 Gb/s
Beyond Cat6®**
PowerSum
TIA/EIA
ISO/IEC
IEEE Gigabit
Belden IBDN System 10GX
625 MHz
10 Gb/s
Beyond 10G
Proposed
TIA
ISO/IEC
IEEE 10 Gigabit
MediaTwist® 1872 (CMR)
MediaTwist 1874 (CMP)
GigaFlex 2412 (CMR)
GigaFlex 2413 (CMP)
GigaFlex 2424 (LSOH)
DataTwist 600e 7851 (CMR)
DataTwist 600e 7852 (CMP)
GigaFlex 4812LX (CMR)
GigaFlex 4813LX (CMP)
GigaFlex 4824LX (LSOH)
10GX 10GX12 (CMR, Nonbonded-pair)
10GX 10GX13 (CMP, Nonbonded-pair)
10GX 10GX24 (LSZH, Nonbonded-pair)
10GX 10GX16 (LC, Nonbonded-pair)
10GX 10GX32 (CMR, Bonded-Pair)
GigaBIX Cross-Connect System
GigaFlex PS6+ Patch Panel
Flex Patch Panel/GigaFlex PS6+ Module
GigaBIX Cross-Connect System
GigaFlex PS6+ Patch Panel
Flex Patch Panel/GigaFlex PS6+ Module
10GX Ultra High-Density Patch Panel (1U, 48 ports)
10GX Patch Panel
Flex Patch Panel/10GX Module
10GX 10GX44 (LSZH, Bonded-Pair)
10GX 10GX66 (LC, Bonded-Pair)
*ANSI/TIA/EIA-568-B.1, ISO/IEC 11801 2nd Edition and IEEE 802.3ab. **ANSI/TIA/EIA-568-B.2, ISO/IEC 11801 2nd Edition and IEEE 802.3ab.
†Backbone can be configured with Belden IBDN FiberExpress Optical Fiber Cable.
Installable Performance guarantees are available on Bonded-Pair cables. Since the insulated conductors of the pairs are bonded along their longitudinal axes,
Bonded-Pair cables remain intact during the installation process, so there is no separation of pair conductors and no degradation of the cables’ electrical characteristics.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.5
Introduction
(continued)
System Certification and
Warranty Program
Belden IBDN systems are designed, installed
and field-tested by full trained and certified
system contractors and integrators to further
assure superior systems performance.
They are also backed by a strict System
Certification and Warranty Program.
The Belden IBDN Certification Program
is a rigorous process that ensures that
your Belden IBDN ‘Certified’ System is
composed of Belden IBDN components,
and that it has been designed and installed
by a factory-trained Certified System
Vendor. Belden IBDN ‘Certified’ Systems
are supported by a series of warranties that
surpass conventional product warranties.
Certification adds important end-to-end
system performance guarantees and
ensures full compliance with cabling
industry standard specifications — even
after system installation (Installable
Performance). A 25-year Product Warranty
and a Lifetime Application Assurance
program accompany each Belden IBDN
'Certified' System installation. These
warranty programs include coverage for
both parts and labor.
Horizontal Cable
Cross-Connect
Patch System
4-Pair Cables
GigaBIX Cross-Connect Wire
GigaBIX Patch Cords
GigaFlex PS5E Modular Cords
Work Area
Installable
Performance® ††
Outlets — Connectors,
Faceplates & Adapters
Modular Cords
DataTwist 350 1700 (CMR)
DataTwist 350 1701 (CMP)
DataTwist 350 1701 (CMP-50)
GigaFlex 1212 (CMR)
GigaFlex 1213 (CMP)
GigaFlex 1224 (LSOH)
•
•
•
PS5E BIX DVO Outlet
EZ-MDVO PS5E Module
GigaFlex PS5E Module
MediaFlex Outlets
Interface Plates
MDVO Faceplates
MDVO Adapters
European-style Faceplates
French-style Faceplates
GigaFlex
PS5E
Modular
Cords
MediaTwist 1872 (CMR)
MediaTwist 1874 (CMP)
GigaFlex 2412 (CMR)
GigaFlex 2413 (CMP)
GigaFlex 2424 (LSOH)
•
•
GigaFlex PS6+ Module
MediaFlex Outlets
Interface Plates
MDVO Faceplates
MDVO Adapters
European-style Faceplates
French-style Faceplates
GigaFlex
PS6+
Modular
Cords
DataTwist 600e 7851 (CMR)
DataTwist 600e 7852 (CMP)
GigaFlex 4812LX (CMR)
GigaFlex 4813LX (CMP)
GigaFlex 4824LX (LSOH)
•
•
GigaFlex PS6+ Module
MediaFlex Outlets
Interface Plates
MDVO Faceplates
MDVO Adapters
European-style Faceplates
French-style Faceplates
GigaFlex
PS6+
Modular
Cords
10GX Module
MediaFlex Outlets
Interface Plates
MDVO Faceplates
MDVO Adapters
10GX
Modular
Cords
PS5E 110 Patch Cords
GigaBIX Cross-Connect Wire
GigaBIX PS6+ Patch Cords
GigaFlex PS6+ Modular Cords
GigaBIX Cross-Connect Wire
GigaBIX PS6+ Patch Cords
GigaFlex PS6+ Modular Cords
10GX Modular Cords
10GX 10GX12 (CMR, Nonbonded-pair)
10GX 10GX13 (CMP, Nonbonded-pair)
10GX 10GX24 (LSZH, Nonbonded-pair)
10GX 10GX16 (LC, Nonbonded-pair)
10GX 10GX32 (CMR, Bonded-Pair)
10GX 10GX33 (CMP, Bonded-Pair)
10GX 10GX44 (LSZH, Bonded-Pair)
10GX 10GX66 (LC, Bonded-Pair)
•
•
•
•
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Quality Installation
And Service
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.6
Belden IBDN System 10GX
10GX Modules and 10GX Patch Panels
10GX Module
AX102272 10GX Module, Black
The 10GX Module is a revolutionary punch down UTP connector designed to be used within the new
Belden IBDN System 10GX. In order to achieve true 10G performance, Belden has designed the 10GX
Module based on three revolutionary module technologies making the 10GX Module the most advanced
10G module available. It is designed to work in existing hardware including the Flex Modular Patch
Panel and MediaFlex Outlet Series. It can also be mixed and matched with a wide variety of adapters
and boxes to suit practically any installation configuration for workstation outlet, consolidation point
and telecommunications closet applications. The unmatched Beyond 10G™ performance exceeds all
parameters specified in the proposed Augmented Category 6 standard. All performance characteristics
including ANEXT, NEXT, FEXT, Insertion Loss and Return Loss have been set to guarantee transmission
performance up to 625 MHz.
Description
Belden Part Number
Belden IBDN System 10GX
10GX Module, Augmented Category 6
MDVO-Style, T568A/B, Gray
MDVO-Style, T568A/B, White
MDVO-Style, T568A/B, Black
MDVO-Style, T568A/B, Red
MDVO-Style, T568A/B, Yellow
MDVO-Style, T568A/B, Green
MDVO-Style, T568A/B, Blue
MDVO-Style, T568A/B, Ivory
AX102269
AX102271
AX102272
AX102274
AX102275
AX102276
AX102277
AX102562
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX102488 10GX Ultra High-Density Patch Panel
1U, 48-port, Titanium
10GX Patch Panel
The 10GX Patch Panel is a fully loaded patch panel designed to be used within the Belden IBDN System
10GX. The 10GX Patch Panel features the revolutionary 10GX Module, specifically designed to meet the
difficult challenges of 10 Gb/s transmission. 10GX Patch Panels are available in high-density options
such as 24 ports in 1U or 48 ports in 2U, but the phenomenal ANEXT performance of the 10GX Module
has allowed Belden to also support an ultra high-density option offering the 10GX Ultra High-Density
Patch Panel supporting 48 ports in 1U. The unmatched Beyond 10G™ performance exceeds all parameters
specified in the proposed Augmented Category 6 standard. All performance characteristics including
ANEXT, NEXT, FEXT, Insertion Loss and Return Loss have been set to guarantee transmission
performance up to 625 MHz.
Description
AX102293 10GX Patch Panel 1U, 24-port, Titanium
Belden Part Number
Belden IBDN System 10GX
10GX Ultra High-Density Patch Panel, Augmented Category 6
1U, 48-port, Titanium
AX102488
10GX Patch Panel, Augmented Category 6
1U, 24-port, Titanium
AX102293
2U, 48-port, Titanium
AX102296
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.7
Belden IBDN System 10GX
10GX Modular Cords
AX360015 10GX Modular Cord, Blue
10GX Modular Cords
Belden Part Number
Description
Blue
White
Gray
Green
Red
Yellow
AX360027
AX360028
AX360029
AX360030
AX360021
AX360022
AX360023
AX360024
AX360045
AX360046
AX360047
AX360048
AX360057
AX360058
AX360059
AX360060
Belden IBDN System 10GX
10GX Modular Cord, 4-Pair, 23 AWG Solid, T568A/B - T568A/B, CMR
2.1 m (7 ft)
AX360015
AX360051
3.0 m (10 ft)
AX360016
AX360052
4.6 m (15 ft)
AX360017
AX360053
7.6 m (25 ft)
AX360018
AX360054
10GX Pigtail, 4-Pair, 23 AWG Solid, T568A — Open, CMR
4.6 m (15 ft)
7.6 m (25 ft)
10.6 m (35 ft)
15.0 m (50 ft)
AX360265
AX360266
AX360267
AX360268
10GX Pigtail, 4-Pair, 23 AWG Solid, T568B — Open, CMR
4.6 m (15 ft)
7.6 m (25 ft)
10.6 m (35 ft)
15.0 m (50 ft)
AX360269
AX360270
AX360271
AX360272
These products are in the process of being assessed for Gb/s compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
The 10GX Modular Cords are 4-pair 23 AWG UTP modular cords designed to be used within the Belden
IBDN System 10GX. Belden has designed the 10GX Modular Cord based on a patent-pending management
bar design which allows for very good control of the internal plug NEXT. The patch cable design offers
very good Alien crosstalk performance, while maintaining the important mechanical characteristics such
as flexibility. The 10GX Modular Cords’ design, with a very small footprint, makes them fully compatible
with the highest density hubs that utilize RJ45 jack connections. The 10GX Modular Cords are available
in pantone colors that match the colors per the TIA/EIA-606 standard and the product line encompasses
CMR modular cords, as well as open-ended cords. The unmatched performance exceeds all parameters
specified in the proposed Augmented Category 6 standard. All performance characteristics have been
set to guarantee transmission performance up to 625 MHz.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.8
Belden IBDN System 10GX
10GX Cables
24826395 10GX Cable Series, White
10GX Cable
The 10GX Cables are 4-pair 23 AWG UTP cables designed to be used within the Belden IBDN System
10GX. The GX Cable incorporates the use of patent-pending SpiralFleX™ technology, which improves the
ANEXT coupling by increasing and randomizing the distance between a cable and the neighboring cables
surrounding it. The unmatched Beyond 10G™ performance exceeds all parameters specified in the proposed Augmented Category 6 standard. All performance characteristics including ANEXT, NEXT, FEXT,
Insertion Loss and Return Loss have been set to guarantee channel transmission performance up to 625
MHz. The 10GX Cable Series is very complete with cable available with Bonded-Pairs and Nonbondedpairs, and is available in plenum, non-plenum, and Limited Combustible versions.
Description
Belden Part Number
10GX Cable, Bonded-Pairs
10GX Cable, CMR
10GX32 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White
10GX32 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Blue
10GX Cable, CMP
10GX33 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White
10GX33 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Blue
10GX Cable, LSZH
10GX44 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Purple
10GX Cable, Limited Combustible
10GX66 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White*
24826395
24826995
24827395
24827995
24828095
24822395
*DuPont™ certified limited combustible cable
10GX Cable, Nonbonded-pairs
10GX Cable, CMR
10GX12 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White
10GX12 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Blue
10GX Cable, CMP
10GX13 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White
10GX13 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Blue
10GX Cable, LSZH
10GX24 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, Purple
10GX Cable, Limited Combustible
10GX16 Cable, 4-Pair, 23 AWG UTP, 305 m (1000 ft), Spool, White*
24816395
24816995
24817395
24817995
24818095
24812395
*DuPont™ certified limited combustible cable
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.9
GigaBIX Multi System
Termination Kits and Basic Components
AX101985 GigaBIX Rack Mount Termination Kit,
48-port
GigaBIX Termination Kits
The GigaBIX Termination Kits contains all components required to terminate cables in a GigaBIX
Cross-Connect or Interconnect System. The Termination Kits allow for the most cost-effective Category 6
cross-connect or interconnect installations using GigaBIX Cross-Connect Wire or GigaBIX PS6+ Patch
Cords. The GigaBIX Mount is designed to accommodate high-performance cables. The GigaBIX
Connectors have color-coded edges, separation marks and a keying feature that prevents connector
insertion in the wrong orientation. Each kit also contains Wire Guards, Designation Strips, Designation
Labels, Velcro ties and a detailed installation guide.
AX101470
GigaBIX
Termination Kit,
72-port
The GigaBIX Connector is the core component of the GigaBIX Multi System. Its symmetrical
construction allows termination of high-performance cables on one side and GigaBIX Cross-Connect
Wires or GigaBIX Patch Cords on the other. Each GigaBIX Connector is equipped with 50 double-ended
Insulation Displacement Connection (IDC) clips for terminating plastic insulated solid copper conductors
without stripping. The connector is built with two staggered rows of IDC clips enclosed in a three-layer
construction of fire-retardant plastic wafers. The GigaBIX Connectors have color-coded edges, separation
marks and a keying feature that prevents connector insertion in the wrong orientation. The GigaBIX
Connector offers exceptional performance that goes Beyond Category 6 which makes it the ideal choice
for gigabit cabling networks.
GigaBIX Mount
The GigaBIX Mount for wall installations holds 12 GigaBIX Connectors and is designed to accommodate
up to 144 high-performance cables when used in a top-to-bottom cross-connect layout.
AX101447 GigaBIX Connector,
6-port
The GigaBIX Rack Mount Panel allows for customizing rack mount installations for data, voice or multimedia
installations. This panel can accommodate up to 8 GigaBIX Connectors, for a total of 48 terminations of 4-pair
UTP cables, or up to 4 GigaBIX/MediaFlex Adapters for a total of 48 multimedia ports.
AX101986 GigaBIX Rack Mount Panel
GigaBIX Wire Guard
The GigaBIX Wire Guards are plastic strips that snap behind the GigaBIX Connectors after termination
to provide strain relief to the twisted pairs. They come as part of the GigaBIX Termination Kits and can
also be ordered separately as replacement components.
GigaBIX Designation Strip
The GigaBIX Designation Strips are plastic strips that snap between the GigaBIX Connectors to apply
the designation labels. They come as part of the GigaBIX Termination Kits and can also be ordered
separately as replacement components. (See the LabelFlex section for designation labels.)
AX101472
GigaBIX Mount
GigaBIX/MediaFlex Adapter
The GigaBIX/MediaFlex Adapter allows for mixed media installation within the expanded GigaBIX Multi
family of connectivity. The GigaBIX/MediaFlex Adapter can accommodate a variety of MediaFlex inserts
including UTP and multimedia inserts to customize multimedia installation in Telecommunications
Rooms, Equipment Rooms, or Consolidation Points.
Description
Belden Part Number
AX101486 GigaBIX Wire Guard
GigaBIX Multi System
AX101483 GigaBIX Designation Strip,
shown here with label
AX101987 GigaBIX/MediaFlex Adapter
Termination Kits
GigaBIX Termination Kit, 72-port
GigaBIX Termination Kit, 300-pair
GigaBIX Rack Mount Termination Kit, 48-port
Basic Components
GigaBIX Connector, 6-port
GigaBIX Connector, 25-pair
GigaBIX Mount, 12-connector
GigaBIX Rack Mount Panel, 48-port
GigaBIX Wire Guard
GigaBIX Designation Strip
GigaBIX/MediaFlex Adapter
AX101470
AX101471
AX101985
AX101447
AX101448
AX101472
AX101986
AX101486
AX101483
AX101987
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
GigaBIX Connector
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.10
GigaBIX Multi System
Patch Cords and Cross-Connect Wire
AX101945 GigaBIX PS6+ Patch Cord, BIX-BIX, 4 ft.
GigaBIX Patch Cords
GigaBIX Patch Cords allow for high-density connections, coupled with flexibility for cost-effective
installation and administration. Plug-and-go installation and rearrangement of patch cords do not
require any special tools or training. GigaBIX Patch Cords are available in two different configurations:
BIX-BIX patch cord configurations for easy cross-connection between equipment and distribution fields,
and BIX-8MOD patch cord configurations to easily interconnect equipment utilizing 8-position modular
jacks directly into GigaBIX Connectors in the distribution field.
The GigaBIX PS6+ Patch Cords are 4-pair 23 AWG UTP cords. They are used in GigaBIX Multi System
as part of a Belden IBDN System 2400 and System 4800LX, providing a channel bandwidth of 250 MHz
and 300 MHz respectively.
The GigaBIX PS5E Patch Cords are used in the GigaBIX Multi System as part of a Belden IBDN System
1200, providing outstanding channel bandwidth of 160 MHz.
AX101951 GigaBIX PS6+ Patch Cord, BIX-8MOD, 4 ft.
Belden Part Number
Description
BIX-BIX
BIX-8MOD
T568A-ISDN
BIX-8MOD
T568B-ALT
AX101945
AX101946
AX101947
AX101948
AX101949
AX101950
AX101951
AX101952
AX101953
AX101954
AX101955
AX101956
AX101957
AX101958
AX101959
AX101960
AX101961
AX101962
AX101963
AX101964
AX101965
AX101966
AX101967
AX101968
AX101969
AX101970
AX101971
AX101972
AX101973
AX101974
AX101975
AX101976
AX101977
AX101978
AX101979
AX101980
GigaBIX Multi System
PS6+ Patch Cords
4 ft. (1.2 m)
6 ft. (1.8 m)
8 ft. (2.4 m)
10 ft. (3.0 m)
15 ft. (4.6 m)
25 ft. (7.6 m)
PS5E Patch Cords
4 ft. (1.2 m)
6 ft. (1.8 m)
8 ft. (2.4 m)
10 ft. (3.0 m)
15 ft. (4.6 m)
25 ft. (7.6 m)
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
24570521 GigaBIX Cross-connect Wire, 4-pair
GigaBIX Cross-Connect Wire
GigaBIX Cross-Connect Wire is intended for use between GigaBIX cross-connect fields in a
Telecommunications Room or in a Main Cross-Connect Frame. Using GigaBIX Cross-Connect Wire
allows for very flexible and cost-effective installations. The cut-to-length jumper eliminates need for
slack management and guarantees permanent installation aesthetics. The GigaBIX Cross-Connect Wire
offers transmission performance that goes Beyond Category 6 providing additional margin to support
Gigabit applications.
Color Code: White/Blue, White/Orange, White/Green, White/Brown.
Description
Belden Part Number
GigaBIX Multi System
Cross-Connect Wire
4-pair, 1000 ft. (305 m), Spool
4-pair, 1000 ft. (305 m), Spool-in-Box
24570521
24577B15
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.11
GigaBIX Multi System
Cable Management Accessories
AX102154 GigaBIX Color-Coded Clip
GigaBIX Colored Service Clips
The GigaBIX Colored Service Clip is a single-pair plastic clip that snaps on the GigaBIX connectors
to visually identify various services when using GigaBIX Cross-Connect Wire.
GigaBIX Cable Management Module
AX101469 GigaBIX Cable Management Module
The GigaBIX Cable Management Module is designed to be used with a wall mount solution. The
accessory allows all terminated cables to be brought from the same side (top or bottom) in a high-density
GigaBIX installation (4-mount stack). The modules are stackable side-to-side and top-to-bottom with
alignment features to ease installation. The modules can be used horizontally to create a horizontal
management channel for more flexibility in a side-to-side patching layout using GigaBIX Patch Cords.
The GigaBIX Patch Cord Organizer is designed to be used with a wall mount solution. The Patch Cord
Organizer is a metal trough that interlocks with GigaBIX Mounts to create a vertical management channel
for GigaBIX Patch Cords. The Patch Cord Organizer has six (6) openings per side to nicely dress the
patch cords while clearing the labeling area on the GigaBIX Mount. The organizer can be assembled
over Cable Management Modules in large patch cord installations. A Patch Cord Organizer Cover can
be purchased separately to hide the patch cords and give a very professional and high-tech look to the
installation.
GigaBIX Horizontal Channel Plate
AX101468 GigaBIX Patch Cord Organizer and
AX101521 GigaBIX Patch Cord Organizer Cover
GigaBIX Horizontal Channel Plates are metal plates that attach to the Patch Cord Organizers to
create a horizontal management channel for GigaBIX Patch Cords. The plates are used in pairs and
are designed to keep patch cords inside the horizontal channel.
GigaBIX Management Ring
The GigaBIX Management Ring is a plastic ring that interlocks with the GigaBIX Mounts to create
a high-density wall mount cross-connect system. The rings are assembled in systems when using
cross-connect wire and have a capacity of 450 GigaBIX Cross-Connect Wires (1800-pairs total).
Description
Belden Part Number
GigaBIX Multi System
AX101520 GigaBIX Horizontal Channel Plate
AX101478 GigaBIX Management Ring
Cable Management Accessories
GigaBIX Color-Coded Clip, Gray
GigaBIX Color-Coded Clip, Almond
GigaBIX Color-Coded Clip, White
GigaBIX Color-Coded Clip, Black
GigaBIX Color-Coded Clip, Orange
GigaBIX Color-Coded Clip, Red
GigaBIX Color-Coded Clip, Yellow
GigaBIX Color-Coded Clip, Green
GigaBIX Color-Coded Clip, Blue
GigaBIX Color-Coded Clip, Purple
GigaBIX Color-Coded Clip, Brown
GigaBIX Cable Management Module
GigaBIX Patch Cord Organizer
GigaBIX Patch Cord Organizer, Cover
GigaBIX Horizontal Channel Plate
GigaBIX Management Ring
AX102146
AX102147
AX102148
AX102149
AX102150
AX102151
AX102152
AX102153
AX102154
AX102155
AX102156
AX101469
AX101468
AX101521
AX101520
AX101478
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
GigaBIX Patch Cord Organizer
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.12
GigaBIX Multi System
Cable Management Accessories
GigaBIX Distribution Frame & Accessories
GigaBIX Distribution Frames provide a compact mounting unit for large cross-connect installations of
data or voice services.
The GigaBIX Distribution Frame can accommodate up to (16) 12-connector GigaBIX Mounts, eight on
the equipment side and eight on the distribution side. The GigaBIX Distribution Frame has a capacity of
1152 ports or 4800 pairs. It is backwards compatible with BIX Mounts (QMBIX12E) and can be used to
continue a row of BIX Distribution Frames (QFBIX24E).
The GigaBIX Frame End Kit consists of eight (8) cable trays and eight (8) distribution rings plus
appropriate mounting hardware. One kit is required to support GigaBIX Cross-Connect Wires on the
sides of a single-frame installation or on the end frames of a multi-frame installation.
The GigaBIX Overhead Kit consists of two (2) metal bars and four (4) “J” bolts plus appropriate mounting
hardware to support cable ladder (not included) running over a row of GigaBIX Distribution Frames.
Description
Belden Part Number
GigaBIX Multi System
Cable Management Accessories
Distribution Frame, 1152 ports/4800 pairs
Frame End Kit
Frame Overhead Kit
AX102073
AX102082
AX102145
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX102073 GigaBIX Distribution Frame
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.13
BIX Cross-Connect System
Distribution Connectors, Multiplying Connectors
and Modular Jack Connectors
A0393146 QCBIX1A4 Connector
BIX Distribution Connector
The BIX Distribution Connector is a 25-pair connector. The connector's symmetrical construction
allows termination of cables on one side and cross-connect jumper wires or BIX Patch Cords on the
other. Each BIX connector is equipped with 50 double-ended Insulation Displacement Connection (IDC)
clips for terminating plastic insulated solid copper conductors without stripping and pair splitters on
each side of the connector facilitate wire insertion.
BIX Multiplying Connector
A0266827 QCBIX5A Multiplying Connector
BIX Multiplying Connectors are used to generate multiple outputs from a single input. Construction of
these connectors is identical to that of BIX Distribution Connectors, except for the IDC clips which are
bridged. BIX Multiplying Connectors are typically used in voice applications.
The QCBIX2A Connector is built using 24 sets of bridged clips (2 clips each). It is used to terminate
various facilities where multiples of 2 are required.
The QCBIX7A Connector is built using 10 sets of bridged clips (four 2-clip and six 7-clip bridged
arrangements). It is primarily intended for use with 1A type key telephone systems. Each connector
can terminate up to three lines of key equipment providing service to as many as seven key telephone
sets per line.
AX100798 BIX Modular Jack Connector
BIX Modular Jack Connector
BIX Modular Jack Connectors provide a fast and flexible method to manage small-to-medium crossconnect installations. These connectors are built with a BIX connector pre-wired to standard modular
jacks. They allow front-access termination and patching.
The NXXCBMC6U Connector is a 6-port, 8-position modular connector used for data applications.
It exceeds all Category 5e channel requirements when used with PS5E Modular Cords in a
Belden IBDN 1200 System.
QCBIX36-type Connectors are used mostly for voice applications. The QCBIX36D connector is a
6-port, 8-position modular connector. It is pre-wired to USOC 8-wire wiring scheme specifications.
The QCBIX36C connector is an 8-port, 6-position modular connector. It is pre-wired to USOC 6-wire
wiring scheme specifications. The QCBIX36B connector is a 12-port, 6-position modular connector.
It is pre-wired to USOC 4-wire wiring scheme specifications.
Description
Belden Part Number
BIX Cross-Connect System
Distribution Connector
BIX Distribution Connector, 5-pair Marking
BIX Distribution Connector, 4-pair Marking
Multiplying Connector
BIX Multiplying Connector, QCBIX2A, 25-pair, 12x2-pair
BIX Multiplying Connector, QCBIX5A, 25-pair, 5x5-pair
BIX Multiplying Connector, QCBIX7A, 25-pair, 2x2-pair & 3x7-pair
Modular Jack Connector
BIX Modular Jack Connector, NXXCBMC6U, 6-port, PS5E, T568A/B Coded
BIX Modular Jack Connector, QCBIX36D, 6-port, USOC, 8-pin
BIX Modular Jack Connector, QCBIX36C, 8-port, USOC, 6-pin
BIX Modular Jack Connector, QCBIX36B, 12-port, USOC, 4-pin
A0266828
A0393146
A0269923
A0266827
A0269925
AX100798
A0341173
A0330864
A0330863
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
The QCBIX5A Connector is built using 10 sets of bridged clips (5 clips each). It is used for multiple
jumper connections to the same equipment.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.14
BIX Cross-Connect System
Mounts, Covers and Wire Management Accessories
A0340836 QMBIX12E BIX Mount, 300-pair
BIX Mount
BIX Mounts are basic components used in building a cross-connect system. They can accept BIX
Distribution, Multiplying or Modular Jack Connectors. The 300 and 250-pair mounts can be
wall-mounted or installed on BIX Frames. These mounts feature an interlocking design allowing
them to be stacked for larger cross-connect installations.
The BIX 50-pair Mount is typically used in small cross-connect installations. Also available is a 50-pair
mount with cover that is sold as an assembly and is typically used in small cross-connect installations
where security and/or dust protection is required.
BIX Cover
A0284798 QMBIX10C BIX Mount, 50-pair
BIX Covers can be used to restrict access of cross-connect installations for better protection and
security. Two sizes are available to suit either the QMBIX12E 300-pair mount or the QMBIX10A
250-pair mount. The two locking covers used in wall or frame-mounted installations are molded
with translucent plastic allowing visual inspection. Also available are two covers used exclusively in
stand-alone QMBIX10A 250-pair mount installations: one locking, the other non-locking—both have
four cable entries, one at each corner.
Distribution Ring
A0277853 QMBIX31A 50-pair Mount
with Locking Cover
The Distribution Ring is used in wall mount installations providing a cross-connect channel for jumper
wires, patch cords and cables. The Distribution Ring interlocks with the QMBIX12E or QMBIX10A
mounts, providing proper spacing and alignment.
Description
A0285986 Locking Cover for 250-pair Mount
A0276396 BIX Cover, QMBIX10A,
Stand-alone installation, Locking
Belden Part Number
BIX Cross-Connect System
BIX Mount
BIX Mount, QMBIX12E (300-pair)
BIX Mount, QMBIX10A (250-pair)
BIX Mount, QMBIX10C (50-pair)
BIX Mount with Cover
BIX Mount with Cover, (Locking), 50-pair
BIX Mount with Cover, (Snap-on), 50-pair
BIX Locking Cover
BIX Locking Cover, for QMBIX12E (300-pair)
BIX Locking Cover, for QMBIX10A (250-pair)
BIX Cover
BIX Cover, QMBIX10A, Stand-alone installation, locking
BIX Cover, QMBIX10A, Stand-alone installation, non-locking
Distribution Ring
Distribution Ring
A0340836
A0270164
A0284798
A0277853
A0277854
A0340838
A0285986
A0276396
A0276394
A0270168
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
A0270168 Distribution Ring
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.15
BIX Cross-Connect System
BIX Distribution Frames, Universal BIX-PAC
and Trunk Access Blocks
BIX Distribution Frame
A0340837 BIX Frame
BIX Distribution Frames provide a compact mounting unit for large cross-connect installations. The
QFBIX24E BIX Frame can accommodate up to 16 QMBIX12E 300-pair mounts, eight on the vertical side
and eight on the horizontal side. The QFBIX24E BIX Frame has a capacity of 4800-pair. The QFBIX24A
BIX Frame can accommodate up to 16 QMBIX10A 250-pair mounts, eight on the vertical side and eight
on the horizontal side. The QFBIX24A BIX Frame has a capacity of 4000-pair.
The BIX Frame End Kit consists of eight cable trays and eight distribution rings plus appropriate mounting
hardware. One kit is required to support cross-connect wires on the sides of the shelves in a singleframe installation or on the end frames of a multi-frame installation.
The Distribution Rings are plastic rings used to manage cross-connect wires.
A0321776 Universal BIX-PAC Version 10-10
The Universal BIX-PAC provides a fast, factory-wired, pre-tested and easy-to-install method of terminating
wiring for the voice environment. A typical application for this product is in the main distribution terminal
system or the riser terminal system, where it can provide connectivity and cross-connection for up to
250 pairs. The units come equipped with up to 10 QCBIX1A Connectors and 10 fifty-pin type telco
connectors for the termination of connectorized cables. Also available is a BIX-PAC Enclosure, which
is a fire-retardant polystyrene structural foam box that can house one BIX-PAC. The enclosure has a
snap-on cover and removable panels for cable entry on top, bottom and sides.
BIX Trunk Access Block
BIX Trunk Access Blocks provide a fast, factory-wired, pre-tested and easy-to-install method for
demarcation or testing points on customer premises. Typical applications are in the building entrance
system or the main distribution terminal system, where the demarcation point between the network
provider and the customer equipment usually can be found.
Description
Belden Part Number
BIX Cross-Connect System
BIX Distribution Frame
BIX Distribution Frame, 4800-pair (4 Shelves for 16 Mounts, 300-pair)
A0340837
BIX Distribution Frame, 4000-pair (4 Shelves for 16 Mounts, 250-pair)
A0275511
BIX Distribution Frame Accessories
BIX Distribution Frame Accessories, End Kit (4 Shelves)
A0275512*
BIX Distribution Frame Accessories, Distribution Ring
P0596540*
Universal BIX-PAC
Universal BIX-PAC, 10-8, 8 RJ21X Female to 8 QCBIX1A Connectors
A0321775
Universal BIX-PAC, 10-10, 10 RJ21X Female to 10 QCBIX1A Connectors
A0321776
BIX PAC Enclosure
BIX PAC Enclosure, Gray
A0318897
BIX Trunk Access Block
BIX Trunk Access Block, 1 RJ21X Female to 1 QCBIX1A Connector
A0327325
BIX Trunk Access Block, 2 RJ21X Female to 2 QCBIX1A Connector
A0327326
*Eight Distribution Rings come as part of the BIX Distribution Frame End Kit. Additional Distribution Rings can be ordered separately.
A0318897 BIX PAC Enclosure
A0327326 BIX Trunk Access Block
Use (1) end kit per row of frames.
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Universal BIX-PAC
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.16
BIX Cross-Connect System
BIX Patch Cords and B-Plus Cross-Connect Wire
A0410494 BIX Patch Cord, BIX-BIX, 2-pair
BIX Patch Cords
BIX Patch Cords allow for high-density connections, coupled with flexibility for cost-effective installation
and administration. Installation and rearrangement of patch cords do not require any special tools or
training. BIX Patch Cord plugs terminate directly into QCBIX1A/1A4 connectors.
B-Plus Cross-Connect Wire
B-Plus Cross-Connect Wire is intended primarily for use between incoming cables and station
equipment in a Telecommunications Room or at a Main Cross-Connect.
Z Cross-Connect Wire is intended primarily for use in voice applications such as cross-connecting
PBX or Key Telephone system equipment to backbone or horizontal distribution cables.
A0410469 BIX Patch Cord, BIX-BIX, 1-pair
Description
Belden Part Number
BIX Cross-Connect System
22208260 B-Plus Cross-Connect Wire
BIX Patch Cord
BIX Patch Cord, BIX-BIX, 2-pair, 1.2 m (4 ft.)
BIX Patch Cord, BIX-BIX, 1-pair, 1.2 m (4 ft.)
BIX Patch Cord, BIX-BIX, 2-pair, 2.1 m (7 ft.)
BIX Patch Cord, BIX-BIX, 1-pair, 2.1 m (7 ft.)
BIX Patch Cord, BIX-BIX, 2-pair, 3.0 m (10 ft.)
BIX Patch Cord, BIX-BIX, 1-pair, 3.0 m (10 ft.)
BIX Patch Cord, BIX-BIX, 2-pair, 4.6 m (15 ft.)
BIX Patch Cord, BIX-BIX, 1-pair, 4.6 m (15 ft.)
BIX Patch Cord, BIX-BIX, 1-pair, 7.6 m (25 ft.)
A0410494
A0410469
A0410495
A0410471
A0410496
A0410473
A0410497
A0410475
A0410493
For 4-pair connections, please see the GigaBIX Patch Cord section.
B-Plus Cross-Connect Wire
24 AWG, 1-pair, Wh/Bl, 305 m (1000 ft.), K-Carton
24 AWG, 1-pair, Wh/Bl, 305 m (1000 ft.), Spool (S77)
24 AWG, 2-pair, Wh/Bl/Wh/Or, 305 m (1000 ft.), K-Carton
24 AWG, 2-pair, Wh/Gr/Wh/Or, 305 m (1000 ft.), K-Carton
24 AWG, 3-pair, Wh/Bl/Wh/Or/Wh/Gr, 152 m (500 ft.), K-Carton
24 AWG, 3-pair, Wh/Bl/Wh/Or/Wh/Gr, 200 m, K-Carton
24 AWG, 4-pair, Wh/Bl/Wh/Or/Wh/Gr/Wh/Br, 152 m (500 ft.), K-Carton
Z Cross-Connect Wire
Z Cross-Connect Wire, 24 AWG, 1-pair, Bl/Ye, 300 m (984 ft.), Spool
Z Cross-Connect Wire, 24 AWG, 1-pair, Bl/Rd, 300 m (984 ft.), Spool
22208250
22208253
22208260
22208231
22208265
22208235
22208270
22208010
22208067
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.17
BIX Cross-Connect System
BIX Tools, Testing Tools,
Accessories and Designation Strip
BIX Connecting Tool
A0270165 BIX Connecting Tool
The BIX Connecting Tool is the only tool required to terminate cables, pigtails or jumper wires on all
GigaBIX and BIX connection products. The BIX Connecting Tool is a spring-activated hand tool. A single
forward movement will seat the wire into the BIX IDC clip and cut off the excess wire. The tool will
terminate 22-26-AWG plastic insulated solid copper conductors. A separate leather BIX Tool Pouch to
carry and protect the BIX Tool can be ordered.
BIX Test Probe
Tool in CUT position
Tool in NO CUT position
The BIX Test Probe is a single-pair probe that clips onto the termination clip of BIX Distribution or BIX
Modular Jack Connectors to facilitate testing.
BIX Accessories
The BIX Bridging Clip is a single-pair clip used to bridge single-pair connections of two BIX
connectors.
The BIX Wire Retainer is a plastic extrusion that fits over the terminated wires on a BIX Connector
to prevent them from being pulled out of the IDC contacts. It can be used to secure a permanent
connection on either side of a BIX Connector.
A0270166 BIX Test Probe
This 19 in. Rack Bracket Kit provides the hardware for BIX Mount installation into a 19 in. rack. This
kit comes complete with two mounting bars, four screws for rack mounting, four screws for BIX Mount
assemblies and an installation guide.
BIX Cable Ties are used for securing wire bundles to the BIX Connector.
BIX Designation Strip
A0270172
Special Service
Guard
The BIX Designation Strip is designed to be used in conjunction with all BIX Mounts and BIX
Connectors. It snaps in between two connectors and provides space for self adhesive BIX labels.
The strip is made of white fire-retardant plastic, with ridges on the top and bottom for easy alignment
and placement of designation labels. (See the LabelFlex section for designation labels.)
Description
A0325493
Bridging Clip
Belden Part Number
BIX Cross-Connect System
BIX Tools
BIX Connecting Tool
Tool Pouch
BIX Test Probe
BIX Test Probe, 1-pair, 1/pack
BIX Accessories
BIX Special Service Guard, 1-pair, Red, 50/pack
BIX Bridging Clip, 1-pair, Gray, 50/pack
BIX Bridging Clip, 1-pair, White, 50/pack
BIX Wire Retainer, 100/pack
19 in. Rack Bracket Kit, 2 bars/pack
BIX Cable Tie, 100/pack
BIX Designation Strip
BIX Designation Strip, White, 50/pack
P0660798 BIX Wire
Retainer
C0039222 BIX
Cable Tie
A0352331 19 in. Rack
Bracket Kit
A0270165
C0054642
A0270166
A0270172
A0325091
A0325493
P0660798
A0352331
C0039222
A0270169
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
A0270169 BIX Designation Strip
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
The BIX Special Service Guard is a single-pair red plastic clip used to identify a connection within a
BIX distribution field that requires special attention prior to any maintenance work.
C0054642
Tool Pouch
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.18
110 Cross-Connect System
110 Cross-Connect Kits, 110 Connecting Blocks,
110 Wall Mount Frame Kits and 110 Wiring Blocks
AX100694 110 Cross-Connect Kit, 100-pair
110 Cross-Connect Kit
110 Cross-Connect Kits contain all material required to terminate distribution or equipment cables into
a 110 Cross-Connect System. Kits consist of one Wiring Block (100-pair or 300-pair) with legs,
Connecting Blocks (4-pair or 5-pair), Designation Strips and Labels.
110 Connecting Block
The 110 Connecting Blocks are modular connectors equipped with double-sided Insulation
Displacement Connection (IDC) clips that are used to terminate plastic insulated solid copper
conductors in 110 Wiring Blocks. The color-coded connecting blocks are available in 4-pair and 5-pair
configurations. These blocks are compatible with other existing 110 Cross-Connect Systems.
AX100696 110 Cross-Connect Kit, 300-pair
110 Wall Mount Frame Kit
110 Wall Mount Frame Kits simplify planning, organizing and implementation of wall mounted
cross-connect systems. They are available in 300-pair and 900-pair configurations making them ideal
for small telecommunications room installations. Kits consist of wiring blocks and cable management
troughs to be mounted on a cable channel. Kits include all components required to complete a
110 Cross-Connect installation with either 4-pair or 5-pair connecting blocks.
110 Wiring Block
AX100707 110
Connecting Block, 4-pair
AX100708 110
Connecting Block, 5-pair
110 Wiring Blocks are rigid plastic indexing strip assemblies designed to hold and align wires prior
to terminating 110 Connecting Blocks. 110 Wiring Blocks are available in 100-pair and 300-pair
configurations with legs and 100-pair without legs. 110 Wiring Blocks are compatible with 22 to 26
AWG wires and accept 4-pair or 5-pair Connecting Blocks. They are specially designed to simplify data
cabling installations. A deeper channel and open slots in the base allow cable to be brought close to the
termination point. These blocks are compatible with other existing 110 Cross-Connect Systems.
Description
Belden Part Number
110 Cross-Connect System
AX100697 110 Wall Mount Frame Kit, 300-pair
AX100692 Wiring Block, 300-pair
110 Cross-Connect Kit
110 Cross-Connect Kit, 100-pair, with 4-pair Connecting Blocks
110 Cross-Connect Kit, 100-pair, with 5-pair Connecting Blocks
110 Cross-Connect Kit, 300-pair, with 4-pair Connecting Blocks
110 Cross-Connect Kit, 300-pair, with 5-pair Connecting Blocks
110 Connecting Block
110 Connecting Block, 110C4, 4-pair
110 Connecting Block, 110C5, 5-pair
110 Wall Mount Frame Kit
110 Wall Mount Frame Kit, 300-pair, with 4-pair Connecting Blocks
110 Wall Mount Frame Kit, 300-pair, with 5-pair Connecting Blocks
110 Wall Mount Frame Kit, 900-pair, with 4-pair Connecting Blocks
110 Wall Mount Frame Kit, 900-pair, with 5-pair Connecting Blocks
110 Wiring Block
110 Wiring Block, 100-pair, without legs
110 Wiring Block, 100-pair, with legs
110 Wiring Block, 300-pair, with legs
AX100693
AX100694
AX100695
AX100696
AX100707
AX100708
AX100697
AX100698
AX100699
AX100700
AX100690
AX100691
AX100692
The 110 Cross-Connect System is not available in all countries.
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX100691 Wiring Block, 100-pair
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.19
110 Cross-Connect System
110 Designation Strip and Management Accessories
AX100721 110 Designation Strip
110 Designation Strip
The 110 Designation Strip is designed to be used in conjunction with all 110 Wiring Blocks. It snaps in
between two rows of 110 Connecting Blocks and provides space to insert a designation label. The strip
is made of clear PVC.
AX100705 Cable Management Trough
110 Management Accessories
Cable Management Troughs are utilized as channels positioned between wiring blocks for horizontal
or vertical dressing of cross-connect wires and patch cords. They are available with and without
mounting legs.
Wall Mount Cable Management Frames are pre-assembled vertical cable managers that are used
between 110 Wall Mount Frame Kits for vertical management of patch cords. They simplify planning
and installation of 110 Cross-Connect Systems. They are available in two sizes to use with 300-pair
and 900-pair Wall Mount Frame Kits.
AX100706 Cable Management Trough with Legs
Description
Belden Part Number
110 Cross-Connect System
AX100703 Cable Management Ring
110 Designation Strip
110 Designation Strip
110 Management Accessories
Cable Management Trough, without legs
Cable Management Trough, with legs
Cable Management Ring, Small 144.8 mm (5.7 in.)
Cable Management Ring, Large 216 mm (8.5 in.)
Wall Mount Cable Management Frame, 300-pair
Wall Mount Cable Management Frame, 900-pair
AX100721
AX100705
AX100706
AX100703
AX100704
AX100701
AX100702
The 110 Cross-Connect System is not available in all countries.
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX100701 Wall Mount Cable Management Frame,
300-pair
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Cable Management Rings are used for management of cross-connect wires and cables in
110 Cross-Connect Systems. They can be mounted directly onto a plywood backboard between
columns of wiring blocks. They are available in two different sizes.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.20
110 Cross-Connect System
110 Patch Cords
AX300001 PS5E 110 Patch Cord, 110-110, 4-pair
110 Patch Cord
110 Patch Cords allow for high density connections in a 110 Cross-Connect System. 110 Patch Cord
rearrangements do not require any special tools or training thus providing flexibility for cost-effective
installation and administration. 110 Patch Cords are available in two different configurations. 110-110
patch cord configurations are used for easy cross-connection between equipment and distribution
fields.
110-8MOD patch cord configurations are used to easily interconnect equipment utilizing 8-position
modular jacks directly into 110C4/C5 connecting blocks in the distribution field. PS5E 110 Patch
Cords offer Category 5e performance. These patch cords are compatible with other existing 110
Cross-Connect systems.
AX300010 PS5E 110 Patch Cord, 110-8MOD, 4-pair
110 Patch Cord Connector
110 Patch Cord Connectors are available in 1, 2 and 4-pair configurations for field assembly of
Category 5 patch cords. They can terminate plastic insulated stranded copper conductors 24 AWG.
Description
Belden Part Number
110 Cross-Connect System
AX300013 110 Patch Cord, 110-110, 2-pair
110 Patch Cord
110 Patch Cord, PS5E 110-110, 4-pair, 1.2 m (4 ft.)
110 Patch Cord, PS5E 110-110, 4-pair, 1.8 m (6 ft.)
110 Patch Cord, PS5E 110-110, 4-pair, 2.4 m (8 ft.)
110 Patch Cord, PS5E 110-110, 4-pair, 3.0 m (10 ft.)
110 Patch Cord, PS5E 110-110, 4-pair, 6.1 m (20 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568A, 1.2 m (4 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568A, 1.8 m (6 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568A, 2.4 m (8 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568A, 3.0 m (10 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568A, 6.1 m (20 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568B, 1.2 m (4 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568B, 1.8 m (6 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568B, 2.4 m (8 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568B, 3.0 m (10 ft.)
110 Patch Cord, PS5E 110-8MOD, 4-pair, T568B, 6.1 m (20 ft.)
110 Patch Cord, 110-110, 2-pair, 1.2 m (4 ft.)
110 Patch Cord, 110-110, 2-pair, 1.8 m (6 ft.)
110 Patch Cord, 110-110, 2-pair, 2.4 m (8 ft.)
110 Patch Cord, 110-110, 2-pair, 3.0 m (10 ft.)
110 Patch Cord, 110-110, 2-pair, 6.1 m (20 ft.)
110 Patch Cord, 110-110, 1-pair, 0.6 m (2 ft.)
110 Patch Cord, 110-110, 1-pair, 1.2 m (4 ft.)
110 Patch Cord, 110-110, 1-pair, 1.8 m (6 ft.)
110 Patch Cord, 110-110, 1-pair, 2.4 m (8 ft.)
110 Patch Cord, 110-110, 1-pair, 3.0 m (10 ft.)
110 Patch Cord, 110-110, 1-pair, 6.1 m (20 ft.)
110 Patch Cord Connector
110 Patch Cord Connector, 4-pair
110 Patch Cord Connector, 2-pair
110 Patch Cord Connector, 1-pair
AX300001
AX300002
AX300025
AX300026
AX300027
AX300010
AX300009
AX300029
AX300030
AX300032
AX300008
AX300005
AX300011
AX300034
AX300017
AX300013
AX300014
AX300015
AX300037
AX300038
AX300039
AX300006
AX300007
AX300012
AX300021
AX300040
AX100711
AX100710
AX100709
The 110 Cross-Connect System is not available in all countries.
Other lengths are available, please contact Customer Service for further details.
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.21
Labels
LabelFlex
AX101537 LabelFlex Labels
LabelFlex Automated Labeling Solution
The LabelFlex solution is aimed at simplifying network management. Using the labeling system
(software and label types), the installer can rapidly produce quality, application specific labels for
most Belden IBDN products in a fraction of the time taken by traditional methods.
The range of Belden IBDN products covered by the labeling system is:
■ GigaBIX & BIX Cross-Connect Systems
■
Flex Patch Panels
■
ID Tubes
■ BIX Modular Jack Connectors
■
Workstation Outlets
■
PS5E HD Patch Panels
■ 110 Cross-Connect System
■
MediaFlex Faceplates series
■ GigaFlex PS6+ Patch Panels
■
Cable Applications, 4-pair and 25-pair
These products are in the process of being assessed for RoHS compliance.
Please check our Web Site for the most current RoHS status.
Labels for MediaFlex Faceplates
Almond/Silver, 30 labels/sheet, 10 sheets/pack
White, 30 labels/sheet, 10 sheets/pack
Labels for BIX and GigaBIX
Gray, 15 labels/sheet, 5 sheets/pack
White, 15 labels/sheet, 5 sheets/pack
Orange, 15 labels/sheet, 5 sheets/pack
Red, 15 labels/sheet, 5 sheets/pack
Yellow, 15 labels/sheet, 5 sheets/pack
Green, 15 labels/sheet, 5 sheets/pack
Blue, 15 labels/sheet, 5 sheets/pack
Purple, 15 labels/sheet, 5 sheets/pack
Brown, 15 labels/sheet, 5 sheets/pack
Silver, 15 labels/sheet, 5 sheets/pack
Labels for BIX Modular Jack Connector
Gray, 28 labels/sheet, 5 sheets/pack
White, 28 labels/sheet, 5 sheets/pack
Orange, 28 labels/sheet, 5 sheets/pack
Red, 28 labels/sheet, 5 sheets/pack
Yellow, 28 labels/sheet, 5 sheets/pack
Green, 28 labels/sheet, 5 sheets/pack
Blue, 28 labels/sheet, 5 sheets/pack
Purple, 28 labels/sheet, 5 sheets/pack
Brown, 28 labels/sheet, 5 sheets/pack
Silver, 28 labels/sheet, 5 sheets/pack
Labels for Patch Panels, Outlets and Cables
Labels for Flex Patch Panels, White, 28 labels/sheet, 5 sheets/pack
Labels for Workstation Faceplates, White, 80 labels/sheet, 25 sheets/pack
Labels for Workstation Single Port ID, White, 450 labels/sheet, 5 sheets/pack
Labels for HD Patch Panels, White, 18 labels/sheet, 5 sheets/pack
Labels for GigaFlex PS6+ Patch Panels, White, 28 labels/sheet, 5 sheets/pack
Labels for 4-pair cables, Gray, 48 labels/sheet, 25 sheets/pack
Labels for 25-pair cables, White, 24 labels/sheet, 25 sheets/pack
Labels for 110 Cross-Connect
Gray, 18 labels/sheet, 5 sheets/pack
White, 18 labels/sheet, 5 sheets/pack
Orange, 18 labels/sheet, 5 sheets/pack
Red, 18 labels/sheet, 5 sheets/pack
Yellow, 18 labels/sheet, 5 sheets/pack
Green, 18 labels/sheet, 5 sheets/pack
Blue, 18 labels/sheet, 5 sheets/pack
Purple, 18 labels/sheet, 5 sheets/pack
Brown, 18 labels/sheet, 5 sheets/pack
Labels for ID Tubes
3.1 in. long, White, 32 labels/sheet, 5 sheets/pack
4.4 in. long, White, 30 labels/sheet, 5 sheets/pack
7.4 in. long, White, 19 labels/sheet, 5 sheets/pack
Software
Automated LabelFlex Advanced Software, 1 CD/pack
Belden Part Number
AX101820
AX101821
AX101532
AX101533
AX101534
AX101535
AX101536
AX101537
AX101538
AX101539
AX101540
AX101541
AX101542
AX101543
AX101544
AX101545
AX101546
AX101547
AX101548
AX101549
AX101550
AX101584
AX101551
AX101552
AX101553
AX101554
AX101626
AX101555
AX101556
AX101557
AX101558
AX101559
AX101560
AX101561
AX101562
AX101563
AX101564
AX101565
AX101566
AX101567
AX101568
AX101569
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Description
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.22
Patch Panels
GigaFlex PS6+ Patch Panels Category 6
AX101613 GigaFlex PS6+ Patch Panel, 2U, 48-port
GigaFlex PS6+ Patch Panel
The GigaFlex PS6+ Patch Panel is a fully loaded patch panel using black GigaFlex PS6+ Modules.
The unmatched performance of the GigaFlex PS6+ Module exceeds all parameters specified in the
Category 6 standard. All performance characteristics including NEXT, FEXT, Attenuation and Return
Loss have been set to guarantee transmission performance up to 300 MHz and a data-rate of up to
4.8 Gb/s.
Description
Belden Part Number
Patch Panels
GigaFlex PS6+ Patch Panel
GigaFlex PS6+ Patch Panel, 1U, 24-port, Gray
GigaFlex PS6+ Patch Panel, 1U, 24-port, Black
GigaFlex PS6+ Patch Panel, 2U, 48-port, Gray
GigaFlex PS6+ Patch Panel, 2U, 48-port, Black
AX101612
AX101611
AX101614
AX101613
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.23
Patch Panels
PS5E HD Patch Panels Category 5E,
PS5E BIX Patch Panels Category 5E and Flex Patch Panels
AX100465 PS5E HD Patch Panel, 1U, 24-port
PS5E HD Patch Panel
The Universal PS5E HD Patch Panels Series includes a variety of product styles, sizes and wiring
configurations. PS5E HD Patch Panels are robust and installer-friendly products by design, combining
punch down connectors with standard modular jacks. They are available in both BIX and 110 Insulation
Displacement Connection (IDC) options. A color-coded icon labeling system can be used to tag each
patch panel port and simplify network management (ordered separately). PS5E HD Patch Panels
offer Category 5E performance.
PS5E BIX Patch Panel
Flex Patch Panel
AX100506 BIX Patch Panel, 2U, 24-port
Flex Patch Panels provide a flexible and versatile termination solution for telecommunications room
rack-mounted installations. The panels can be custom configured in the field to suit practically any
particular configuration. Flex Patch Panels are compatible with GigaFlex and EZ-MDVO modules as
well as MDVO-style Multimedia modules. Modules are ordered separately.
Description
Belden Part Number
Patch Panels
AX101456 Flex Patch Panel
PS5E HD Patch Panel
PS5E HD-BIX Patch Panel, 1U, 24-port, Gray, T568A/B
PS5E HD-BIX Patch Panel, 1U, 24-port, Black, T568A/B
PS5E HD-BIX Patch Panel, 2U, 48-port, Gray, T568A/B
PS5E HD-BIX Patch Panel, 2U, 48-port, Black, T568A/B
PS5E HD-110 Patch Panel, 1U, 24-port, Black, T568B/A
PS5E HD-110 Patch Panel, 2U, 48-port, Black, T568B/A
AX100464
AX100465
AX100472
AX100473
AX100452
AX100454
The PS5E HD-110 Patch Panel is not available in all countries.
Other configurations are available, please contact Customer Service for further details.
PS5E BIX Patch Panel
PS5E BIX Patch Panel, 2U, 24-port, Gray, T568A-ISDN
PS5E BIX Patch Panel, 2U, 24-port, Black, T568A-ISDN
Flex Patch Panel
Flex Patch Panel, 1U, 24-port, Gray
Flex Patch Panel, 1U, 24-port, Black
Flex Patch Panel, 2U, 48-port, Gray
Flex Patch Panel, 2U, 48-port, Black
AX100505
AX100506
AX101571
AX101456
AX101573
AX101458
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
AX100473 PS5E HD Patch Panel, 2U, 48-port
The PS5E BIX Patch Panel is a medium density panel, 24-port in 2 rack space units, for easier
installation and cable management than high density panels. The PS5E BIX Patch Panel is a robust and
installer-friendly product by design, combining BIX punch down connectors with standard modular
jacks. The patch panel features built-in wire management to secure cable bundles and to control and
maintain patch cord bend radius. A color-coded icon labeling system can be used to tag each patch
panel port and simplify network management (ordered separately). The PS5E BIX Patch Panel offers
Category 5E performance.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.24
Patch Panels
PS5E HD Patch Boxes Category 5E,
Connector Modules and Identification Accessories
AX100284 HD Patch Box, Closed
PS5E HD Patch Box
The PS5E HD Patch Boxes are available in BIX and 110 configurations and hold one 12-port universal connector
module in a compact and robust metal enclosure. The patch box features a hinged cover and support brackets to
secure cables and maintain patch cord bend radius. A color-coded icon labeling system can be used to tag each
patch panel port and simplify network management (ordered separately) All performance parameters, including
NEXT, Attenuation and Return Loss are designed to meet the Category 5E Cabling standard.
An MDVO Patch Box is also available that can be custom configured in the field using up to 12 GigaFlex,
EZ-MDVO or MDVO Multimedia Modules. Modules are ordered separately.
AX100284 HD Patch Box, Open
PS5E HD-BIX Universal Connector Module
The PS5E HD Universal Connector Module is a 12-port UTP Module with a BIX or 110 termination interface
that is used as a replacement module in the PS5E HD Patch Panels and Patch Boxes.
PS5E BIX Connector Module
The PS5E BIX Connector Module is a 2-port UTP Module with BIX termination interface that is used
as a replacement module in the PS5E BIX Patch Panel 24-port.
AX100282 MDVO Patch Box
Color-Coded Icon Kit
Color-Coded Icons can be used to tag each outlet port as data or voice and simplify network management.
The snap-on icons can be used with PS5E HD Patch Panels, PS5E HD Patch Boxes, PS5E BIX Patch Panels,
MediaFlex GigaFlex Inserts, PS5E DVO Workstation Outlets. They cannot be used with any of the Interface or
MDVO plates, adapters or boxes.
Clear Plastic Identification Tubes
The Clear Plastic ID Tubes are new and improved plastic tubes designed to be used primarily in conjunction
with the PS5E HD BIX and 110 Patch Panels and Patch Boxes. The tubes are made of clear fire-retardant
plastic, with double-sided adhesive on one side. They are available in three different lengths for easy compatibility
with 4, 6 or 12-port openings of the patch panels. They are sold in bags of 100 units only. The bags contain 100
ID tubes and 100 white labels.
AX100461
HD-110 Universal
Connector Module
Description
Belden Part Number
Patch Panels
PS5E HD-BIX Patch Box
PS5E HD-BIX Patch Box, 12-port, Gray, T568A/B
PS5E HD-BIX Patch Box, 12-port, Black, T568A/B
PS5E HD-110 Patch Box, 12-port, Black, T568B/A
AX100458 HD-BIX
Universal Connector Module
AX100599 PS5E BIX Connector Module, Front
The PS5E HD-110 Patch Box is not available in all countries.
MDVO Patch Box
MDVO Patch Box, 12-port, Gray
MDVO Patch Box, 12-port, Black
PS5E HD-BIX Universal Connector Module
PS5E HD-BIX Universal Connector Module, Universal wiring 12-port, T568A/B
PS5E HD-110 Universal Connector Module, Universal wiring 12-port, T568B/A
AX100599 PS5E BIX Connector Module, Back
AX100435
Color-Coded
Icon Kit
AX101093 Clear ID Tubes
These products are in the process of being assessed for RoHS compliance.
Please check our Web Site for the most current RoHS status.
AX100283
AX100284
AX100491
AX100281
AX100282
AX100458
AX100461
The PS5E HD-110 Universal Connector Module is not available in all countries.
PS5E BIX Connector Module
PS5E BIX Connector Module, 2-port, T568A-ISDN
Color-Coded Icon Kit
Color-Coded Icon Kit, Gray, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Almond, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, White, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Black, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Orange, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Red, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Yellow, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Green, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Blue, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Purple, 12 data, 6 voice, 6 blank icons
Color-Coded Icon Kit, Brown, 12 data, 6 voice, 6 blank icons
Clear Plastic Identification Tubes
Clear Plastic Identification Tubes, 188 mm (7.4 in.), HDBIX/110
Clear Plastic Identification Tubes, 112 mm (4.4 in.), MDVO Patch Box
Clear Plastic Identification Tubes, 79 mm (3.1 in.), MDVO, 4-port
AX100599
AX100435
AX100436
AX100437
AX100438
AX100439
AX100440
AX100441
AX100442
AX100443
AX100444
AX100445
AX101093
AX101094
AX101095
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.25
Workstation Outlets
GigaFlex PS6+ Modules Category 6
AX101067 GigaFlex PS6+Module
GigaFlex PS6+ Module
The GigaFlex PS6+ Module is a punch down UTP connector based on a patented Encapsulated Lead
Frame technology ensuring excellent long-term reliability as well as extremely stable transmission
performance. The unmatched Beyond Cat6 performance exceeds all parameters specified in the
Category 6 standard. All performance characteristics have been set to guarantee transmission
performance up to 300 MHz and a data-rate of up to 4.8 Gb/s.
The GigaFlex PS6+ is the module of choice for terminating UTP cables into the MediaFlex and Interface
Outlet Series. It can also be mixed and matched with a wide variety of MDVO adapters, boxes and patch
panels to suit practically any installation configuration for workstation outlet, consolidation point and
telecommunications room applications.
A keystone-style is also available for terminating UTP cables into keystone-style mounting hardware.
It can be easily snapped into simple sheet metal cut-outs (panel mounting) for installation into
consolidation point or multi-user custom-built devices.
Belden Part Number
Description
MDVO-Style
Keystone-Style
Clipsal-Style
AX101063
AX101064
AX101065
AX101066
AX101067
AX101068
AX101069
AX101070
AX101071
AX101072
AX101073
AX102563
AX101318
AX101319
AX101320
AX101321
AX101322
AX101323
AX101324
AX101325
AX101326
AX101327
AX101328
AX101340
AX101341
AX101342
AX101343
AX101344
AX101345
AX101346
AX101347
AX101348
AX101349
AX101350
Workstation Outlets
GigaFlex PS6+ Module
T568A/B, Gray
T568A/B, Almond
T568A/B, White
T568A/B, Black
T568A/B, Orange
T568A/B, Red
T568A/B, Yellow
T568A/B, Green
T568A/B, Blue
T568A/B, Purple
T568A/B, Brown
T568A/B, Ivory
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Also available is the GigaFlex PS6+ Module, Clipsal-style which is fully compatible with Clipsal
faceplates and mounting hardware.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.26
Workstation Outlets
GigaFlex PS5E Modules Category 5E and
Flex Modules, USOC-coded
AX101051 GigaFlex PS5E Module
GigaFlex PS5E Module
The GigaFlex PS5E Module is a punch down UTP connector based on a patented Encapsulated Lead
Frame technology ensuring excellent long term reliability as well as extremely stable transmission
performance. The PS5E-rated performance exceeds all requirements specified in the Category 5e
standard. All performance parameters including NEXT, FEXT, Attenuation and Return Loss have been
set to guarantee transmission performance up to 160 MHz and a data-rate of up to 1.2 Gb/s.
The GigaFlex PS5E is the module of choice for terminating UTP cables into the MediaFlex and Interface
Outlet Series. It can also be mixed and matched with a wide variety of MDVO adapters, boxes and patch
panels to suit practically any installation configuration for workstation outlet, consolidation point and
telecommunications room applications.
AX101037 Flex Module, USOC-coded
A keystone-style is also available for terminating UTP cables into keystone-style mounting hardware.
It can be easily snapped into simple sheet metal cut-outs (panel mounting) for installation into consolidation
point or multi-user custom-built devices.
Flex Module, USOC-coded
The Flex Module USOC-coded is a punch down UTP connector that has a narrower plug entrance and
a USOC 6-pin color code in the back. These modules are used for voice applications and are designed
to prevent connecting the computer into the analog phone jack, which may cause damages to the
electronics.
The Flex Module is the module of choice for voice applications in the MediaFlex and Interface Outlet
Series. It can also be mixed and matched with a wide variety of MDVO adapters, boxes and patch
panels to suit practically any installation configuration for workstation outlet, consolidation point and
telecommunications rooms applications.
Belden Part Number
Description
MDVO-Style
Keystone-Style
AX101044
AX101045
AX101046
AX101047
AX101048
AX101049
AX101050
AX101051
AX101052
AX101053
AX101054
AX102564
AX101307
AX101308
AX101309
AX101310
AX101311
AX101312
AX101313
AX101314
AX101315
AX101316
AX101317
Workstation Outlets
GigaFlex PS5E Module
T568A/B, Gray
T568A/B, Almond
T568A/B, White
T568A/B, Black
T568A/B, Orange
T568A/B, Red
T568A/B, Yellow
T568A/B, Green
T568A/B, Blue
T568A/B, Purple
T568A/B, Brown
T568A/B, Ivory
Flex Module, USOC-coded, 6-position
Gray
Almond
White
Black
Orange
Red
Yellow
Green
Blue
Purple
Brown
Ivory
AX101033
AX101034
AX101035
AX101036
AX101037
AX101038
AX101039
AX101040
AX101041
AX101042
AX101043
AX102565
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.27
Workstation Outlets
EZ-MDVO PS5E Modules Category 5E
and EZ-MDVO Modules, USOC-coded
AX100654 EZ-MDVO PS5E Module
EZ-MDVO PS5E Module
The EZ-MDVO Module is built with a patented lead frame design and encapsulated insulation
displacement contacts, ensuring reliable connections and performance well above Category 5E
standards. The EZ-MDVO module termination cap is what is so unique about this product. It allows
for a simple and fast “press-fit” installation while ensuring consistent wire termination every time it is
snap-locked. The module termination cap is color-coded to facilitate wire arrangement and speed up
installation time. The termination cap is printed with the T568A/B color-codes. The EZ-MDVO Modules
can be mixed and matched with a wide variety of MediaFlex, Interface and MDVO-style faceplates,
adapters and boxes to suit practically any installation configuration for workstation outlet installations.
AX100177 EZ-MDVO Module, USOC-coded
A keystone-style is also available for terminating UTP cables into keystone-style mounting hardware.
It can be easily snapped into simple sheet metal cut-outs (panel mounting) for installation into
consolidation point or multi-user custom-built devices. Clipsal-style EZ-MDVO Modules are available
for installations using commercially available Clipsal faceplates and HPM-style EZ-MDVO Modules are
available for installations using commercially available HPM faceplates.
The EZ-MDVO Module USOC-coded has a narrower plug entrance and is designed to be used for voice
applications. These modules prevent connecting the computer into the analog phone jack, which may
cause damages to the electronics. Also available is the EZ-MDVO Module, USOC-coded keystone style.
Belden Part Number
Description
MDVO-Style
Keystone-Style
Clipsal-Style
HPM-Style
AX100678
AX100679
AX100680
AX100681
AX100682
AX100683
AX100684
AX100685
AX100686
AX100687
AX100688
AX100667
AX100668
AX100669
AX100670
AX100671
AX100672
AX100673
AX100674
AX100675
AX100676
AX100677
Workstation Outlets
EZ-MDVO PS5E Module
T568A/B coded, Gray
AX100645
AX100577
T568A/B coded, Almond
AX100646
AX100578
T568A/B coded, White
AX100647
AX100579
T568A/B coded, Black
AX100648
AX100580
T568A/B coded, Orange
AX100649
AX100581
T568A/B coded, Red
AX100650
AX100582
T568A/B coded, Yellow
AX100651
AX100583
T568A/B coded, Green
AX100652
AX100584
T568A/B coded, Blue
AX100653
AX100585
T568A/B coded, Purple
AX100654
AX100586
T568A/B coded, Brown
AX100655
AX100587
EZ-MDVO Module, USOC-coded, 6 position
Gray
AX100171
AX100588
Almond
AX100172
AX100589
White
AX100173
AX100590
Black
AX100174
AX100591
Orange
AX100175
AX100592
Red
AX100176
AX100593
Yellow
AX100177
AX100594
Green
AX100178
AX100595
Blue
AX100179
AX100596
Purple
AX100180
AX100597
Brown
AX100181
AX100598
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
EZ-MDVO Module, USOC-coded
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.28
Workstation Outlets
MediaFlex Faceplate Kits and MediaFlex Plates
AX101786 MediaFlex Faceplate Kit, 6-port
MediaFlex Faceplate Kit
MediaFlex Plates and Inserts snap together to create a full line of modular workstation outlets. This
product line, called the MediaFlex Modular Outlet Series, has been designed with the help of
industrial designers as well as other professionals in the industry in order to combine flexibility, ease
of use and high-tech aesthetics for work area installations.
Even though the MediaFlex series is a modular outlet system, ease and flexibility in ordering and
inventory management are also considered with the offering of pre-configured faceplate kits (includes
plate, flush MDVO-style inserts, filler inserts, MDVO blank, labeling window covers, labeling paper and
all necessary mounting screws).
AX101779 MediaFlex Faceplate Kit, 2-port
MediaFlex Plate
MediaFlex Plates are one part of the comprehensive line of plates and inserts that snap together to
create a full line of modular workstation outlets.
MediaFlex Plates can be mounted over standard NEMA type outlet boxes and rings to provide support
for a variety of MediaFlex Adapters and Inserts. The fully modular construction combined with the front
access design provides extensive configuration flexibility for current and future network needs.
MediaFlex Plates are available in Single gang and Double gang configurations.
AX101785 MediaFlex Faceplate Kit, 4-port
The Double gang faceplate comes with a stand-off ring included in the package. This ring allows for
easy mounting with virtually any industry electrical box or mud/adapter rings, therefore providing added
installation flexibility.
Each plate has the capacity of up to 6 ports per Single gang and 12 ports per Double gang.
Belden Part Number
Description
2-Port Flush
4-Port Flush
6-Port Flush
AX101778
AX101779
AX101780
AX101781
AX102621
AX102566
AX101782
AX101783
AX101784
AX101785
AX102622
AX102567
AX101786
AX101787
AX101788
AX101789
AX102623
AX102568
Workstation Outlets
AX101748 MediaFlex Plate, Single Gang
MediaFlex Faceplate Kit
Gray
Almond
Elec. White
Black
White
Ivory
AX101869 MediaFlex Plate, Double Gang
Belden Part Number
Description
MediaFlex Plate
Gray
Almond
Elec. White
Black
White
Ivory
Single Gang
Double Gang
AX101745
AX101746
AX101747
AX101748
AX102608
AX102569
AX101869
AX101870
AX101871
AX101872
AX102609
AX102570
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.29
Workstation Outlets
MediaFlex Adapter Boxes and MediaFlex Inserts
AX101874 MediaFlex Adapter Box, Double Gang
MediaFlex Surface Adapter Box
MediaFlex Surface Adapter Boxes are one part of the comprehensive line of plates and inserts that
snap together to create a full line of modular workstation outlets.
MediaFlex Surface Adapter Boxes can be mounted over standard NEMA type outlet boxes and rings to
provide support for the MediaFlex plates. The MediaFlex Surface Adapter Boxes are available as a Double
gang configuration. The Double gang box allows more room for cable management and bend radius control.
Belden Part Number
Description
Gray
Almond
Elec. White
Black
White
Ivory
AX102480
AX101873
AX102481
AX101874
AX102482
AX101875
AX102483
AX101876
AX102484
AX102610
AX102485
AX102571
Workstation Outlets
MediaFlex Adapter Box
Single Gang
Double Gang
MediaFlex Inserts provide optimum flexibility in configuring multimedia workstation outlets that respond to
any present or future network needs. MediaFlex MDVO-style Inserts along with MediaFlex Filler Inserts and
MediaFlex GigaFlex Inserts allow for the easy configuration of outlets. All inserts are front loaded and easily
snapped in and out of the MediaFlex Plates for simple installation and maintenance.
MediaFlex MDVO-style Inserts are available in a 2-port configuration in both Flush and Angled versions.
They are compatible with all GigaFlex and MDVO Modules (EZ-MDVO and Multimedia). The inserts are two
units high for the flush version and three units high for the angled version. Therefore three flush inserts or
two angled inserts are required to fully populate a Single gang MediaFlex Plate.
MediaFlex GigaFlex Inserts are available in a 2-port configuration in both PS5E (Category 5E) and PS6+
(Beyond Category 6) performance levels. The inserts are two units high, therefore three inserts can be used
to fully populate a Single gang MediaFlex Plate making up a 6-port outlet.
AX101752 MediaFlex MDVO (style) Insert,
2-port, Flush
MediaFlex Filler Inserts are used to fill the unused spaces in low density workstation outlets.
They are available in one unit and two unit sizes.
Description
Belden Part Number
Flush
Angled
AX101749
AX101750
AX101751
AX101752
AX102612
AX102572
AX101753
AX101754
AX101755
AX101756
AX102613
AX102573
Workstation Outlets
AX101760 MediaFlex Filler Insert, 1-unit
AX101764 MediaFlex Filler Insert, 2-unit
AX101768 PS6+ MediaFlex GigaFlex Insert, 2-port
MediaFlex MDVO (style) Insert
2-port, Gray, bag of 10 units
2-port, Almond, bag of 10 units
2-port, Elec. White, bag of 10 units
2-port, Black, bag of 10 units
2-port, White, bag of 10 units
2-port, Ivory, bag of 10 units
Description
MediaFlex GigaFlex Insert
2-port, Gray
2-port, Almond
2-port, Elec. White
2-port, Black
2-port, Ivory
Description
These products are in the process of being assessed for RoHS compliance.
Please check our Web Site for the most current RoHS status.
MediaFlex Filler Insert
Gray, bag of 10 units
Almond, bag of 10 units
Elec. White, bag of 10 units
Black, bag of 10 units
White, bag of 10 units
Ivory, bag of 10 units
Belden Part Number
PS6+
PS5E
AX101765
AX101766
AX101767
AX101768
AX102574
AX101769
AX101770
AX101771
AX101772
AX102575
Belden Part Number
1-Unit
2-Unit
AX101757
AX101758
AX101759
AX101760
AX102614
AX102576
AX101761
AX101762
AX101763
AX101764
AX102615
AX102577
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
MediaFlex Insert
AX101756 MediaFlex MDVO (style) Insert,
2-port, Angled
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.30
Workstation Outlets
MediaFlex Inserts (continued)
and Accessories
AX101878 MediaFlex RCA Insert, 3-port, Angled
MediaFlex Multimedia Insert
MediaFlex Multimedia Inserts provide optimum flexibility in configuring multimedia workstation
outlets that respond to any present or future network needs. MediaFlex Multimedia Inserts along with
other MediaFlex Inserts allow for easy configuration of outlets. All inserts are front loaded and easily
snapped in and out of the MediaFlex Plates for easy installation and maintenance.
MediaFlex Multimedia inserts include the following products:
■ 3-Port RCA insert with IDC termination
■ SVHS insert with IDC termination, and feedthrough
■ SVGA (DB15) insert with IDC termination ■ SC Duplex inserts in MM and SM
AX101882 MediaFlex SVHS Insert, 1-port, Angled
MediaFlex Multimedia Inserts are available in Angled versions only in order to allow for proper
management of cable bend radius. The inserts are three units high, therefore two inserts are required to
fully populate a Single gang faceplate and four inserts will fully populate a Double gang faceplate.
Labeling Window Cover/Dust Cover
MediaFlex Accessories include Labeling Window Covers used with the MediaFlex faceplates and Dust
Covers used with the MediaFlex GigaFlex Inserts. Dust Covers can also be used with standard GigaFlex
and EZ-MDVO UTP Modules.
Description
AX101886 MediaFlex SVGA Insert, 1-port, Angled
AX101937 MediaFlex SC Duplex Insert, Angled
AX101777 Labeling Window Cover
AX101790 Dust Cover
These products are in the process of being assessed for RoHS compliance.
Please check our Web Site for the most current RoHS status.
MediaFlex Multimedia Insert
3-port RCA, Gray
3-port RCA, Almond
3-port RCA, Elec. White
3-port RCA, Black
3-port RCA, White
3-port RCA, Ivory
1-port SVHS, Gray
1-port SVHS, Almond
1-port SVHS, Elec. White
1-port SVHS, Black
1-port SVHS, White
1-port SVHS, Ivory
1-port SVGA, Gray
1-port SVGA, Almond
1-port SVGA, Elec. White
1-port SVGA, Black
1-port SVGA, White
1-port SVGA, Ivory
SVGA Feedthrough, Gray
SVGA Feedthrough, Almond
SVGA Feedthrough, Elec. White
SVGA Feedthrough, Black
SVGA Feedthrough, White
SVGA Feedthrough, Ivory
SC Duplex Single-mode, Gray
SC Duplex Single-mode, Almond
SC Duplex Single-mode, Elec. White
SC Duplex Single-mode, Black
SC Duplex Single-mode, White
SC Duplex Single-mode, Ivory
SC Duplex Multimode, Gray
SC Duplex Multimode, Almond
SC Duplex Multimode, Elec. White
SC Duplex Multimode, Black
SC Duplex Multimode, White
SC Duplex Multimode, Ivory
MediaFlex Accessories
Window Cover, Clear, bag of 25 units
Window Cover, Gray, bag of 25 units
Window Cover, Almond, bag of 25 units
Window Cover, Elec. White, bag of 25 units
Window Cover, Black, bag of 25 units
Dust Cover, Clear, bag of 50 units
Belden Part Number
AX101877
AX101878
AX101879
AX101880
AX102616
AX102578
AX101881
AX101882
AX101883
AX101884
AX102617
AX102579
AX101885
AX101886
AX101887
AX101888
AX102618
AX102580
AX102334
AX102335
AX102336
AX102337
AX102630
AX102581
AX101935
AX101936
AX101937
AX101938
AX102619
AX102649
AX101939
AX101940
AX101941
AX101942
AX102620
AX102650
AX101773
AX101774
AX101775
AX101776
AX101777
AX101790
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.31
Workstation Outlets
MDVO Faceplates Flush and Angled
A0405257 MDVO Faceplate, 1-port
MDVO Faceplate, Flush
MDVO Faceplates flush combine ease of use and aesthetics in work area installations. The Single gang
faceplates are available in 1-port and 8-port configurations, Double gang faceplates are configured for
12-ports. The Single gang faceplates can fit over the Interface Surface Adapter Boxes for surface mount
installations.
MDVO faceplates are suitable for use with EZ-MDVO and MDVO Multimedia Modules.
MDVO Angled Entry Faceplate
Description
Belden Part Number
Workstation Outlets
A0620807 MDVO Faceplate, 12-port
A0645267 MDVO Angled Entry Faceplate,
shown here with modules
MDVO Faceplate
Flush, 1-port, Single Gang, Gray
Flush, 1-port, Single Gang, Almond
Flush, 1-port, Single Gang, White
Flush, 1-port, Single Gang, Black
Flush, 1-port, Single Gang, Ivory
Flush, 8-port, Single Gang, Gray
Flush, 8-port, Single Gang, Almond
Flush, 8-port, Single Gang, White
Flush, 8-port, Single Gang, Black
Flush, 8-port, Single Gang, Ivory
Flush, 12-port, Double Gang, Gray
Flush, 12-port, Double Gang, Almond
Flush, 12-port, Double Gang, White
Flush, 12-port, Double Gang, Black
Flush, 12-port, Double Gang, Ivory
MDVO Angled Entry Faceplate
4-port, Gray
4-port, Almond
4-port, White
4-port, Black
4-port, Ivory
A0405255
A0405256
A0405257
A0405258
AX102585
A0405294
A0405295
A0405296
A0405298
AX102586
A0620806
A0620807
A0620808
A0620809
AX102587
A0645267
A0645268
A0645269
A0645270
AX102588
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
A0405294 MDVO Faceplate, 8-port
The MDVO Angled Entry Faceplate offers better patch cord protection than traditional faceplates and
optimizes patch cord bend radius control. The MDVO Angled Entry Faceplate can accept up to four
EZ-MDVO or MDVO Multimedia Modules. The faceplate can be attached to standard electrical boxes
or wall-mounting hardware for flush-mount installations. The faceplate can also fit over the Interface
Surface Adapter Box for surface mount installations.
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.32
Workstation Outlets
Interface Plate and
Surface Adapter Boxes
AX101431 Interface Plate, 2-port,
shown here with modules
Interface Plate, Flush
Interface Plates combine flexibility and ease of use in work area installations. They are designed
to accept the EZ-MDVO and GigaFlex UTP modules as well as all the MDVO Multimedia Modules.
The Interface Plates are available in Single gang and can accept up to 6 modules. They also have
labeling capabilities using built-in labeling windows. The faceplates can be attached to standard
electrical boxes or wall-mounting hardware for flush-mount installations. The faceplates can also
fit over the Interface Adapter Boxes for surface mount installations.
Interface/MDVO Surface Adapter Box
AX101438 Interface Plate, 4-port,
shown here with modules
The Interface/MDVO Surface Adapter Box allows surface mounting of Interface Plates as well as
MDVO Flush and Angled entry faceplates. The box can be mounted on any flat surface or can be
attached to standard electrical boxes or wall-mounting hardware for additional storage space.
Description
Belden Part Number
Workstation Outlets
AX101441 Interface Plate, 6-port,
shown here with modules
AX101474 Interface/MDVO Surface Adapter Box
Interface Plate
Flush, 2-port, Gray
Flush, 2-port, Almond
Flush, 2-port, White
Flush, 2-port, Black
Flush, 2-port, Ivory
Flush, 4-port, Gray
Flush, 4-port, Almond
Flush, 4-port, White
Flush, 4-port, Black
Flush, 4-port, Ivory
Flush, 6-port, Gray
Flush, 6-port, Almond
Flush, 6-port, White
Flush, 6-port, Black
Flush, 6-port, Ivory
Interface/MDVO Surface Adapter Box
Single Gang, Gray
Single Gang, Almond
Single Gang, White
Single Gang, Black
Single Gang, Ivory
AX101431
AX101432
AX101433
AX101434
AX102582
AX101435
AX101436
AX101437
AX101438
AX102583
AX101439
AX101440
AX101441
AX101442
AX102584
AX101474
AX101475
AX101476
AX101477
AX102589
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.33
Workstation Outlets
MDVO Adapters
A0645271 MDVO Side Entry Box, shown here
with modules
MDVO Adapters
All MDVO Adapters are compatible with GigaFlex, EZ-MDVO and MDVO Multimedia Modules.
The MDVO Side Entry Box can be easily mounted directly on the wall, as well as on modular furniture
panels, baseboards and utility poles. The compact size of the box allows secure installation in confined
areas such as behind a desk or underneath a workstation.
The MDVO 106 Adapters are designed for installations using standard NEMA electrical-style
faceplates also referred to as 106-type or duplex wall plates.
The MDVO Deco Adapter is designed for installations using Decora style wall plates.
MDVO Modular Furniture Adapters are the ideal outlet adapters for open office furniture applications.
They can be snapped into any standard opening, in modular furniture settings.
AX100311 MDVO 106 Adapter, 4-port,
shown here with modules
Belden Part Number
Workstation Outlets
A0409654 MDVO Deco Adapter,
shown here with modules
AX100925 MDVO Modular Furniture Adapter, 4-port,
shown here with modules
MDVO Adapters
MDVO Side Entry Box, 2-port, Gray
MDVO Side Entry Box, 2-port, Almond
MDVO Side Entry Box, 2-port, White
MDVO Side Entry Box, 2-port, Black
MDVO Side Entry Box, 2-port, Ivory
MDVO 106 Adapter, 2-port, Gray
MDVO 106 Adapter, 2-port, Almond
MDVO 106 Adapter, 2-port, White
MDVO 106 Adapter, 2-port, Black
MDVO 106 Adapter, 2-port, Ivory
MDVO 106 Adapter, 4-port, Gray
MDVO 106 Adapter, 4-port, Almond
MDVO 106 Adapter, 4-port, White
MDVO 106 Adapter, 4-port, Black
MDVO 106 Adapter, 4-port, Ivory
MDVO Deco Adapter, 3-port, Gray
MDVO Deco Adapter, 3-port, Almond
MDVO Deco Adapter, 3-port, White
MDVO Deco Adapter, 3-port, Black
MDVO Deco Adapter, 3-port, Ivory
MDVO Modular Furniture Adapter, 3-port, Gray
MDVO Modular Furniture Adapter, 3-port, Almond
MDVO Modular Furniture Adapter, 3-port, White
MDVO Modular Furniture Adapter, 3-port, Black
MDVO Modular Furniture Adapter, 3-port, Ivory
MDVO Modular Furniture Adapter, 4-port, Gray
MDVO Modular Furniture Adapter, 4-port, Almond
MDVO Modular Furniture Adapter, 4-port, White
MDVO Modular Furniture Adapter, 4-port, Black
MDVO Modular Furniture Adapter, 4-port, Ivory
A0645271
A0645272
A0645273
A0645274
AX102590
AX100304
AX100305
AX100306
AX100307
AX102591
AX100308
AX100309
AX100310
AX100311
AX102592
A0409651
A0409652
A0409653
A0409654
AX102593
A0407071
A0407072
A0407073
A0407074
AX102648
AX100925
AX100926
AX100927
AX100928
AX102594
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Description
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.34
Workstation Outlets
Stainless Steel Faceplate
AX102007 2-port Stainless Steel SG Faceplate
Keystone-style, shown here with modules
Stainless Steel Faceplate
Belden’s Stainless Steel Faceplates are ideal for labs, sanitary, medical,
and harsh environment type applications.
They are designed to accept Keystone-style modules. The Stainless Steel Faceplates are
available as Single Gang and Double Gang, and can accept up to 12 modules. A studded version
designed to support a wall phone is also offered. Stainless Steel Faceplates can be attached
to standard NEMA type outlet boxes or wall-mounting hardware for flush-mount installation.
Stainless Steel Faceplates are cULus Listed.
Please note : For use only with Keystone-style modules such as GigaFlex PS6+,
GigaFlex PS5E and EZ-MDVO Modules.
Description
AX102012 6-port Stainless Steel DG Faceplate
Keystone-style, shown here with modules
Belden Part Number
Workstation Outlets
Stainless Steel Faceplate
1-Port Stainless Steel SG Faceplate - Keystone-style studded for Phone
1-Port Stainless Steel SG Faceplate - Keystone-style
2-Port Stainless Steel SG Faceplate - Keystone-style
3-Port Stainless Steel SG Faceplate - Keystone-style
4-Port Stainless Steel SG Faceplate - Keystone-style
6-Port Stainless Steel SG Faceplate - Keystone-style
4-Port Stainless Steel DG Faceplate - Keystone-style
6-Port Stainless Steel DG Faceplate - Keystone-style
12-Port Stainless Steel DG Faceplate - Keystone-style
AX102005
AX102006
AX102007
AX102008
AX102009
AX102010
AX102011
AX102012
AX102013
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.35
Workstation Outlets
European Style Faceplates and Inserts
AX101372-73 European “6C” Style Faceplates
and AX101377-75-76 European “6C” Inserts
European “6C” Style Faceplate
The European “6C” Style faceplates and Inserts are designed to accept the GigaFlex
and EZ-MDVO UTP Modules.
They include a shutter to protect the module against dust and other contaminants.
French Style Faceplate
The French Style Faceplates are designed to accept the EZ-MDVO and GigaFlex UTP modules as well as
all the MDVO multimedia modules. The faceplates can be attached to standard 45 mm x 45 mm boxes
or mounting hardware for flush-mount installations.
AX101413-14 French Style Faceplates
Description
Belden Part Number
European “6C” Style Faceplate
European “6C” Style Faceplate, Single Gang, Single Aperture, White
European “6C” Style Faceplate, Single Gang, Dual Aperture, White
European “6C” Style Faceplate, Double Gang, Quad Aperture, White
European “6C” Shuttered Module Holder, 1-port, Flush, White
European “6C” Shuttered Module Holder, 1-port, Angled, White
European “6C” Blank Insert, White
French Style Faceplate
1-port, Flush, White
2-port, Flush, White
1-port, Angled, White
2-port, Angled, White
AX101372
AX101373
AX101374
AX101375
AX101376
AX101377
AX101413
AX101414
AX101415
AX101416
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX101415-16 French Style Faceplates
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Workstation Outlets
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.36
Workstation Outlets
MDVO Multimedia Outlet Boxes,
Multi-User Outlet Boxes and Multi-User Adapter Strips
A0643205 MDVO Multimedia Outlet Box,
shown here as terminated
MDVO Multimedia Outlet Box
The MDVO Multimedia Outlet Box brings unique versatility for multimedia work area installations.
The box design provides cable management and helps maintain cable bend radius. The outlet box’s
low profile design and side-entry offers better protection for patch cords. The outlet box can accept up
to six EZ-MDVO, GigaFlex or MDVO Multimedia Modules or three SC Duplex adapters.
The MDVO Multimedia Outlet Box can be mounted directly on the wall or attached to standard
electrical boxes. Included with the MDVO Multimedia box are three SC Duplex Mounting bezels and
three MDVO Adapters.
Multi-User Outlet Box
The Multi-User Outlet Box is a versatile box that can be used in many different applications. The
outlet box can accommodate up to 24 connections of any type, UTP, fiber or coax. The outlet box is
ideal for use as a multi-user telecommunications assembly, or simply as a high-density multimedia
telecommunications outlet. The Multi-User Outlet Box can also be used as a wall mounted patch panel
in confined areas, such as shallow rooms and cabinets.
Multi-User Adapter Strips
The Multi-User Outlet Box design allows for mixed media installations with a choice of connection
strips. The box can accept either one or two 12-port MDVO Adapter Strips, PS5E HD Connector
Module Strips (BIX or 110), or a combination of both for a maximum of 24 connections.
AX100222 Multi-User Outlet Box,
shown here with modules
Description
Belden Part Number
Workstation Outlets
AX100223 MDVO Adapter Strip, 12-port
MDVO Multimedia Outlet Box
6-port, Gray
6-port, Almond
6-port, White
6-port, Black
6-port, Ivory
Multi-User Outlet Box
24-port, Gray
24-port, Almond
24-port, White
24-port, Black
Multi-User Adapter Strips
MDVO Adapter Strip, 12-port, Empty, Black
PS5E HD-BIX Connector Module Strip, Universal Wiring 12-port, T568A/B
PS5E HD-110 Connector Module Strip, Universal Wiring 12-port, T568B/A
A0643205
A0643206
A0643207
A0643208
AX102595
AX100219
AX100220
AX100221
AX100222
AX100223
AX100224
AX100494
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.37
Workstation Outlets
MDVO Multimedia Modules
A0407005 MDVO SC Fiber Module
MDVO Multimedia Module
MDVO Multimedia Modules address audio/video and fiber applications. Fiber modules are available for
LC Duplex, SC Simplex, ST Compatible multimode and MT-RJ multimode & single-mode connections.
The SC Duplex Adapter is a fiber adapter sleeve with flanges that mounts into the SC Duplex mounting
bezel (included in the MDVO Multimedia Outlet box). Audio/video modules are available for SVHS, RCA,
BNC and Video F connections.
Description
A0649254 SC Duplex Adapter
Belden Part Number
Gray
Almond
White
Black
Ivory
A0407010 MDVO ST Compatible Fiber Module
MDVO Multimedia Module
LC Duplex Multimode
AX102209
AX102210
LC Duplex Single-mode
AX102213
AX102214
SC Simplex, Multimode
A0407003
A0407004
SC Duplex Adapter, Multimode
A0649254
ST Compatible, Multimode
A0407007
A0407008
MT-RJ, Multimode
AX101467
MT-RJ, Single-mode, Blue
AX101466
Description
AX101467 MDVO MTRJ Fiber Module
Coaxial, BNC
Coaxial, Video F
RCA, feedthru, White insert
RCA, feedthru, Yellow insert
RCA, feedthru, Red insert
RCA, feedthru, Black insert
SVHS, feedthrough
3.5mm Stereo
AX102211
AX102215
A0407005
AX102619
AX102216
A0407006
AX102596
A0407009
A0407010
AX102597
Black Holder
Ivory Holder
A0406998
A0407002
AX101826
AX101830
AX101834
AX101838
AX101842
AX102627
AX102598
AX102599
AX102601
AX102602
AX102603
AX102604
AX102605
AX102628
Belden Part Number
Gray Holder
Almond Holder
A0406995
A0406999
AX101823
AX101827
AX101831
AX101835
AX101839
AX102624
A0406996
A0407000
AX101824
AX101828
AX101832
AX101836
AX101840
AX102625
White Holder
A0406997
A0407001
AX101825
AX101829
AX101833
AX101837
AX101841
AX102626
Custom multimedia connectors are also available, please contact Customer Service for more details.
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
A0406997 MDVO BNC Coaxial Module
A0406999 MDVO Video F Coaxial Module
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Workstation Outlets
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.38
Workstation Outlets
PS5E BIX DVO Outlets
and Double Gang Outlet
PS5E BIX DVO Outlet
PS5E BIX DVO Outlets
The PS5E BIX DVO Workstation Outlets are robust and installer-friendly products, combining
punch-down connectors with standard modular jacks. The outlet's unique, completely enclosed housing
protects the connectors and allows the wires to be front-terminated on BIX Insulation Displacement
Connectors (IDC). The snap-on cover plate allows easy access and eliminates visible mounting screws.
PS5E BIX DVO Workstation Outlets offer headroom over the Category 5e cabling standard.
PS5E BIX DVO Double Gang Outlet
PS5E BIX DVO Double Gang Workstation Outlets offer high capacity outlet configuration options in the
work area. They are created by combining PS5E BIX DVO Connector Modules and DVO Double Gang
Faceplates.
Each faceplate can accept up to two connector modules. A color-coded icon labeling system can be
used to tag each outlet port and simplify network management.
AX100601 PS5E BIX DVO Module
Belden Part Number
Description
1-Port
2-Port
4-Port
AX100382
AX100383
AX100384
AX100385
AX100386
AX100387
AX100388
AX100389
AX100334
AX100335
AX100336
AX100337
AX100338
AX100339
AX100340
AX100341
AX100390
AX100391
AX100392
AX100393
AX100394
AX100395
AX100396
AX100397
AX100342
AX100343
AX100344
AX100345
AX100346
AX100347
AX100348
AX100349
AX100398
AX100399
AX100400
AX100401
AX100402
AX100403
AX100404
AX100405
AX100350
AX100351
AX100352
AX100353
AX100354
AX100355
AX100356
AX100357
Workstation Outlets
AX100613 DVO Faceplate, 3-port
AX100640 DVO Faceplate, 4-port
PS5E BIX DVO Outlets
Surface, T568A-ISDN, Gray
Surface, T568A-ISDN, Almond
Surface, T568A-ISDN, White
Surface, T568A-ISDN, Black
Surface, T568B-ALT, Gray
Surface, T568B-ALT, Almond
Surface, T568B-ALT, White
Surface, T568B-ALT, Black
Flush, T568A-ISDN, Gray
Flush, T568A-ISDN, Almond
Flush, T568A-ISDN, White
Flush, T568A-ISDN, Black
Flush, T568B-ALT, Gray
Flush, T568B-ALT, Almond
Flush, T568B-ALT, White
Flush, T568B-ALT, Black
Description
Belden Part Number
T568A-ISDN
PS5E BIX DVO Double Gang Outlet
PS5E BIX DVO Connector
AX100601
Module, Flush, 1-port, Gray
PS5E BIX DVO Connector
AX100602
Module, Flush, 2-port, Gray
DVO Double Gang Faceplate,
Flush, Gray
DVO Double Gang Faceplate,
Flush, Almond
DVO Double Gang Faceplate,
Flush, White
DVO Double Gang Faceplate,
Flush, Black
T568B-ALT
3-Port
4-Port
AX100613
AX100640
AX100614
AX100641
AX100615
AX100642
AX100616
AX100643
AX100604
AX100605
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.39
Workstation Outlets
Outlet Accessories
A0405538 MDVO Blank Insert
MDVO Blank Insert
MDVO Blank Inserts can be used in any MediaFlex outlets, Interface plates, MDVO faceplates,
adapters or boxes to fill in unused ports.
Colored Bezel
The Colored Bezels are plastic inserts that fit over the face of GigaFlex and EZ-MDVO Modules to
modify their color. They are particularly useful in installations where the churn rate is high and color
identification of outlets is critical (ex.: segmented network with security levels). They also contribute
to simplifying the management of the cabling infrastructure by using only one color of module for
Moves, Adds and Changes (MACs).
ID Tab
ID Tabs are color-coded identification caps that can be inserted over the GigaFlex and EZ-MDVO
Modules. The ID tabs are available as blank, data or voice coded. They are available in eleven colors
to facilitate identification and to match modern office decor.
The flexible identification cap also acts as a protective cover eliminating exposure to dust and
other contaminants when the module is not in use.
Belden
Part Number
Description
Workstation Outlets
AX100196 ID Tab
MDVO Blank Insert
Gray
Almond
White
Black
Electric White
Ivory
Colored Bezel
Gray
Almond
White
Black
Orange
Red
Yellow
Green
Blue
Purple
Brown
Ivory
Description
ID Tab
Gray
Almond
White
Black
Orange
Red
Yellow
Green
Blue
Purple
Brown
A0405536
A0405537
A0405538
A0405539
AX102607
AX102600
AX102014
AX102015
AX102016
AX102017
AX102018
AX102019
AX102020
AX102021
AX102022
AX102023
AX102024
AX102606
Belden Part Number
Blank
Data
Voice
AX100182
AX100183
AX100184
AX100185
AX100186
AX100187
AX100188
AX100189
AX100190
AX100191
AX100192
AX100193
AX100194
AX100195
AX100196
AX100197
AX100198
AX100199
AX100200
AX100201
AX100202
AX100203
AX100204
AX100205
AX100206
AX100207
AX100208
AX100209
AX100210
AX100211
AX100212
AX100213
AX100214
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
AX102022 Colored Bezel
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.40
Workstation Outlets
Tools
AX100749 GigaFlex Connecting Tool
GigaFlex Connecting Tool
The GigaFlex Connecting Tool is a no-impact connecting tool used to terminate cables, pigtails or
cross-connect wires on any GigaFlex Module or 110 product. The GigaFlex Tool is a spring-activated
hand tool. A single forward movement will seat the wire into the IDC clip and cut off the excess wire.
The tool will terminate 22, 24 and 26-AWG plastic insulated solid copper conductors.
Bonded-Pair Cable Preparation Tool
1797B Cable Preparation Tool
The Bonded-Pair Cable Preparation Tool makes it faster and easier to prepare cables for connector
termination. This tool is ideal for use with Belden’s DataTwist® 350, MediaTwist®, and DataTwist® 600e
Bonded-Pair cables, providing special features that help separate twisted pairs. It can also be used to
prepare any nonbonded-pair cable for installation.
Termination Station
The Termination Station is an ergonomically designed holder that provides stability to the GigaFlex
Module during the termination process. The station has pockets with locking features that steadily
holds either MDVO-style or Keystone-style GigaFlex Modules or MediaFlex Inserts during pair
placement and wire termination. Cable retainers on each end of the station will secure and hold cables
during the pair placements process. The flat bottom surface will provide the required stability to safely
terminate the modules. The tool is made of very durable plastic and its low profile makes it an easy tool
to use and carry.
AX101852 Termination Station
Outlet Release Tool
The Outlet Release Tool is a very convenient tool for servicing the MediaFlex and Interface outlets.
Its bent tip allows for easy front removal of MediaFlex inserts, especially when used in Angled Entry
plates. It is also very useful to extract GigaFlex Modules from miscellaneous mounting hardware and to
remove the protective cap for GigaFlex Module re-termination.
Description
Belden Part Number
Workstation Outlets
AX101185 Outlet Release Tool
Tools
GigaFlex Connecting Tool
Bonded-Pair Cable Preparation Tool
Termination Station
Outlet Release Tool
AX100749
1797B
AX101852
AX101185
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.41
Modular Cords
GigaFlex PS6+ Modular Cords and GigaFlex PS6+ Bonded Modular Cords
Enhanced Category 6
AX350061 GigaFlex PS6+ Modular Cord
GigaFlex PS6+ Modular Cord
The GigaFlex PS6+ Modular Cords are 4-pair 23 AWG UTP modular cords designed for use with the
Belden IBDN Systems 2400 and 4800LX, providing channel bandwidths of 250 MHz and 300 MHz,
respectively. The GigaFlex PS6+ Modular Cords have been designed to provide a mated-connection
performance that exceeds the Category 6 requirements.
The GigaFlex PS6+ Modular Cord’s patented design, with a very small footprint, makes them fully
compatible with any of the highest density hubs with RJ45 jack connections.
Belden Part Number
Description
Blue
White
Gray
Green
Red
Yellow
GigaFlex PS6+ Modular Cord, CMR 4-pair, 23 AWG solid, T568A/B-T568A/B
0.6 m (2 ft.) AX350037
AX350043
AX350049
AX350055
AX350061
AX350067
1.2 m (4 ft.) AX350038
AX350044
AX350050
AX350056
AX350062
AX350068
2.1 m (7 ft.) AX350039
AX350045
AX350051
AX350057
AX350063
AX350069
3.0 m (10 ft.) AX350040
AX350046
AX350052
AX350058
AX350064
AX350070
4.6 m (15 ft.) AX350041
AX350047
AX350053
AX350059
AX350065
AX350071
7.6 m (25 ft.) AX350042
AX350048
AX350054
AX350060
AX350066
AX350072
4-pair, 23 AWG solid, T568A/B-open
4.6 m (15 ft.)
AX350160
7.6 m (25 ft.)
AX350161
10.6 m (35 ft.)
AX350162
15.0 m (50 ft.)
AX350163
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
AX380014 GigaFlex PS6+ Bonded Modular Cord
GigaFlex PS6+ Bonded Modular Cords
The GigaFlex PS6+ Bonded Modular Cords are 4-pair 24 AWG Bonded-Pair UTP modular cords
designed for use with the Belden IBDN Systems 2400 and 4800LX, providing channel bandwidths of
250 MHz and 300 MHz, respectively. The GigaFlex PS6+ Bonded Modular Cords have been designed to
provide a mated-connection performance that exceeds the Category 6 requirements.
The GigaFlex PS6+ Bonded Modular Cord’s patented design, with a very small footprint, makes them
fully compatible with the highest density hubs, with any RJ45 jack connections. The special cord design
offers increased stability in crosstalk and impedance performance to support the many moves, adds
and changes performed in the lifetime of the system.
Description
Belden Part Number
Blue
Gray
White
Yellow
Modular Cords
GigaFlex PS6+ Bonded Mod. Cord, CMR, 4-pr, Bonded 24 AWG solid, T568A/B-T568A/B
1.2 m (4 ft.)
AX380014
AX380026
AX380050
AX380056
2.1 m (7 ft.)
AX380015
AX380027
AX380051
AX380057
3.0 m (10 ft.)
AX380016
AX380028
AX380052
AX380058
4.6 m (15 ft.)
AX380017
AX380029
AX380053
AX380059
7.6 m (25 ft.)
AX380018
AX380030
AX380054
AX380060
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Modular Cords
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.42
Modular Cords
GigaFlex PS5E Modular Cords and GigaFlex PS5E VoIP Cords Category 5E
AX350013 GigaFlex PS5E Modular Cord
GigaFlex PS5E Modular Cord
The GigaFlex PS5E Modular Cords are 4-pair 24 AWG UTP modular cords that are designed for
use with the Belden IBDN Plus Cabling System and the Belden IBDN System 1200 providing channel
bandwidths of 100 MHz and 160 MHz, respectively.
The GigaFlex PS5E Modular Cord’s patented design features a very small footprint, making them
fully compatible with the highest density hubs which use RJ45 jack connections. The GigaFlex
PS5E Modular Cords have been designed to provide a mated-connection performance that exceeds
the Category 5e standard.
Description
Belden Part Number
Blue
White
Gray
Green
Red
Yellow
Modular Cords
GigaFlex PS5E Mod. Cord, CMR 4-pr, 24 AWG stranded, T568A/B-T568A/B
0.6 m (2 ft.) AX350001
AX350007
AX350013
AX350019
AX350025
AX350031
1.2 m (4 ft.) AX350002
AX350008
AX350014
AX350020
AX350026
AX350032
2.1 m (7 ft.) AX350003
AX350009
AX350015
AX350021
AX350027
AX350033
3.0 m (10 ft.) AX350004
AX350010
AX350016
AX350022
AX350028
AX350034
4.6 m (15 ft.) AX350005
AX350011
AX350017
AX350023
AX350029
AX350035
7.6 m (25 ft.) AX350006
AX350012
AX350018
AX350024
AX350030
AX350036
AX330015 GigaFlex PS5E VoIP Modular Cord
GigaFlex PS5E VoIP Modular Cords
The GigaFlex PS5E VoIP Modular Cords are 4-pair 24 AWG UTP modular cords that are designed for
use with the Belden IBDN Plus Cabling System and the Belden IBDN System 1200 providing channel
bandwidths of 100 MHz and 160 MHz, respectively. The GigaFlex PS5E VoIP Modular Cord is designed
for use with VoIP phones that can not accommodate standard booted patch cords which would make
the phone unstable or difficult to wall mount. The GigaFlex PS5E VoIP Modular Cord is designed with a
regular booted RJ 45 plug on one end (at the wall) and a bootless very short body RJ 45 plug on the
other end (at the phone). The GigaFlex PS5E VoIP Modular Cords meet all the enhanced Category 5
modular cord requirements as per the Category 5e standard, and are completely backward compatible
with Category 5 jacks. The GigaFlex PS5E VoIP Modular Cords have been designed to provide a matedconnection performance that exceeds the Category 5e standard. The GigaFlex PS5E VoIP Modular Cord
product line encompass CMR-rated cords.
Description
VoIP Modular Cord features
very short body RJ 45 phone
connector on other end
Belden Part Number
Blue
White
Gray
Green
Red
Yellow
Modular Cords
GigaFlex PS5E VoIP Mod.Cord, CMR, 4-pair, 24
0.6 m (2 ft.) AX330013
AX330049
AX330025
1.2 m (4 ft.) AX330014
AX330050
AX330026
2.1 m (7 ft.) AX330015
AX330051
AX330027
3.0 m (10 ft.) AX330016
AX330052
AX330028
4.6 m (15 ft.) AX330017
AX330053
AX330029
7.6 m (25 ft.) AX330018
AX330054
AX330030
AWG stranded,T568A/B-T568A/B
AX330019
AX330043
AX330055
AX330020
AX330044
AX330056
AX330021
AX330045
AX330057
AX330022
AX330046
AX330058
AX330023
AX330047
AX330059
AX330024
AX330048
AX330060
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.43
Modular Cords
Category 5e Modular Cords
Category 5e Modular Cord
Category 5e Modular Cords are made of plenum and riser rated 24 AWG patch cable.
Description
Belden Part Number
Blue
Green
Red
White
Yellow
Gray
Modular Cords
Cat. 5e Modular Cord, CMR, 4-pair, 24 AWG stranded, T568A/B-T568A/B
0.6 m (2 ft.) 23518027
23528027
23538027
23548027
23568027
23598027
1.2 m (4 ft.) 23518047
23528047
23538047
23548047
23568047
23598047
2.1 m (7 ft.) 23518077
23528077
23538077
23548077
23568077
23598077
3.0 m (10 ft.) 23518107
23528107
23538107
23548107
23568107
23598107
4.6 m (15 ft.) 23518157
23528157
23538157
23548157
23568157
23598157
7.6 m (25 ft.) 23518257
23528257
23538257
23548257
23568257
23598257
Cat. 5e X-Over Cord, 4-pair, 24 AWG stranded, T568A-T568B X-Over
2.1 m (7 ft.)
23598074
4.6 m (15 ft.)
23598154
7.6 m (25 ft.)
23598254
Description
Belden Part Number
CMR
CMP
Modular Cords
Cat. 5e Modular Cord, Gray, 4-pair, 24 AWG solid, T568A/B-T568A/B
2.1 m (7 ft.)
23498077
23338077
3.0 m (10 ft.)
23498107
23398107
7.6 m (25 ft.)
23498257
23398257
15.0 m (50 ft.)
23498507
23398507
20.1 m (66 ft.)
23498667
23398667
Cat. 5e Pigtails, Gray, 4-pair, 24 AWG solid, T568A/B-open
3.0 m (10 ft.)
23498105
—
4.6 m (15 ft.)
23498155
—
7.6 m (25 ft.)
23498255
23398255
10.6 m (35 ft.)
23498355
23398355
15.0 m (50 ft.)
23498505
23398505
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Category 5e Modular Cord
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.44
Network Connectivity Products
Media Converters, Transceivers & Hubs and Network Tester
Media Converters for Ethernet and Fast Ethernet
Media Converters
Media Converters enable the connection of dissimilar network cabling types, while maintaining the same
network speed. A legacy Thinnet segment can be connected to a 10Base-T Hub or switch port with a
AX-200 Converter or, link two different 10Base-T networks together over a multimode fiber optic link with
a pair of AX-270s. Connect a legacy Thinnet segment over fiber with the AX-280 converter. The AX-5270
can be used for interbuilding links or attached to a fiber backbone.
Transceivers and Ethernet Hubs
The AX-50, 70 and 80 Transceivers enable the connection of a legacy AUI port to 10Base-T, Thinnet,
or Fiber Optic media. The transceiver is powered from the host and requires no external power supply.
AX-1912 Media Converter Rack
The AX-509 Ethernet Hub has an AUI port which accepts UTP, Fiber Optic or BNC transceivers. Specified
for use by many U.S. Government Agencies. Includes a 110v/12v power supply.
Realtime 10/100 Base-TX Ethernet Network Test Unit
The AX-110BT Realtime 10/100 Base-TX Ethernet Network Test Unit is a cost effective way to quickly
determine a network's operating condition. Plug the unit's patch cord into the tester then into any open
RJ-45 jack in an office, cubicle or conference room. Immediately see if the jack is a live network node
capable of either 100 Mb/s or 10 Mb/s. Next check patch cord continuity and polarity. Connect the
downlink to a PC to check NIC card link, speed and full or half duplex capabilities. Connect the uplink
to a hub or switch port to verify link and speed.
AX050, 70 and 80 Transceivers and
AX-509 Ethernet Hub
Description
Belden Part Number
Network Connectivity Products
AX-110BT Realtime 10/100 Base-TX Ethernet Network
Test Unit
Media Converter
10Base-T/10Base2, RJ-45 to BNC
10Base-T/10Base-FL, RJ-45 to ST-Compatible fiber connectors
10Base2/10Base-FL, BNC to ST-Compatible fiber connectors
100Base-TX/100Base-FX, SC-Compatible fiber connectors
100Base-TX/100Base-FX, ST-Compatible fiber connectors
Media Converter Rack
Holds up to 12 converters and multi lead power supplies,
19 in. rack-mount ready
Power Supply, 4-lead 110v/12v, powers up to 4 converters
Power Supply, 8-lead 110v/12v, powers up to 8 converters
Transceivers and Ethernet Hubs
UTP Transceiver, 10Base-T, AUI to RJ-45, side port
UTP Transceiver, 10Base-T, AUI to RJ-45, rear port
Fiber Transceiver, 10Base-FL, AUI to ST-Compatible
Thinnet Transceiver, 10Base2, AUI to BNC
Ethernet Hub with 8 RJ-45 10Base-T ports and 1 AUI port
Network Tester
Realtime 10/100 Base-TX Ethernet Network Test Unit
AX-200
AX-270
AX-280
AX-5270SC
AX-5270ST
AX-1912-MCR
AX-270P4U
AX-270P8U
AX-50
AX-50R
AX-70
AX-80
AX-509
AX-110BT
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.45
Line Protection and Bonding & Grounding
IDC 4-pair Protector Modules, PVCI Ground Wires, Bond Clamp and Accessories
AX100826 Cat-5e, 4-pair Protector
IDC 4-pair Protector Module
The IDC 4-pair Protector Module is a high-performance Category 5e, solid-state protection for Local
Area Networks. Protects sensitive electronic workstations, network equipment, and cables from damage
caused by transient voltage surges. Provides 100% protection with easy-to-install BIX or 110 IDC
termination in a convenient 4-pair module.
Description
Belden Part Number
Line Protection
AX100826
AX100827
PVCI Ground Wire
PVCI Ground Wire
PVCI Ground Wire consists of 6, 10, 12 and 14 AWG Solid annealed copper conductors individually
insulated with polyvinyl chloride compound.
Bond Clamp
The Bond Clamps are used to attach the cable shield to the ground via Ground Wire. They are
recommended for use with Riser Cables and Outside Plant Cables. The bond clamps consist of heavy
plates and a securing nut with an integral spring washer. The plates are curved to conform to the
contours of the cable. The upper plate has “teeth” which penetrate the polyethylene cable jacket and
align with the perforations in the lower plate. The lower plate has burred perforations that penetrate
into the metallic sheath of the cable.
X9905753 Bond Clamp
Accessories
A Six-position Ground Bracket is used to terminate and ground up to 5 cable sheaths. The sixth position
on the bracket is used to provide the ground return to the Distribution Terminal and is not available to
ground a cable.
Two Ground Wire Clips on each side of the ground wire are required to ground one cable.
AX100226 Six-position Ground Bracket
Description
Belden Part Number
Bonding & Grounding
X9908359 6 AWG Ground Wire Clip
PVCI Ground Wire
PVCI Ground Wire, 6 AWG, Black, 75 m (246 ft.), Coil
PVCI Ground Wire, 10 AWG, Black, 50 m (164 ft.), Coil
PVCI Ground Wire, 12 AWG, Almond, 50 m (164 ft.), Coil
PVCI Ground Wire, 14 AWG, Olive Gray, 75 m (246 ft.), Coil
Bond Clamp
Bond Clamp, QCF1A 19 mm (0.75 in.) cable and above
Bond Clamp, QCF2A 19 mm (0.75 in.) cable and below
Accessories
Bond Clamp Accessories, Six-position Ground Bracket
Bond Clamp Accessories, 6 AWG Ground Wire Clip
22214348
22214500
22214700
22214900
X9905753
X9905754
AX100226
X9908359
These products are in the process of being assessed for RoHS compliance. Please check our Web Site for the most current RoHS status.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
IDC 4-pair Protector Module
IDC Protector Module, Category 5e, 4-pair, BIX Protector, 1/pack
IDC Protector Module, Category 5e, 4-pair, 110 Protector, 1/pack
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.46
DataTwist 600e UTP Cable
®
TIA/EIA-568-B.2-1, Category 6
Enhanced Category 6 Bonded-Pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Certified System Cable
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Bonded-Pairs Solid Bare Copper Conductors • Patented E-Spline Center Member • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Black, White or Gray)
7851A
NEC:
CMR
CEC:
CMR
4
1000
A-1000
304.8
A-304.8
38.0
47.0
17.2
21.3
.227 5.77
x
x
.315 8.00
8.2
3.0
65.6
1
10
31.25
62.5
100
155
200
250
350
400
500
550
600
1.9
5.7
10.2
14.7
18.9
23.9
27.5
31.2
37.7
40.6
46.2
48.8
51.4
80.3
65.3
57.9
53.4
50.3
47.5
45.8
44.3
40.2
39.3
37.8
37.2
36.6
78.5
59.6
47.7
38.7
31.4
23.5
18.3
13.2
4.5
0.6
>0*
—
—
70.8
50.8
40.9
34.9
30.8
27.0
24.8
22.8
19.9
18.8
16.8
16.0
15.2
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±22
100±22
100±22
100±22
100±22
20.0
25.0
25.0
25.0
25.0
22.8
21.7
20.5
19.8
19.5
18.4
18.0
17.6
8.2
3.0
65.6
1
10
31.25
62.5
100
155
200
250
350
400
500
550
600
1.9
5.7
10.2
14.7
18.9
23.9
27.5
31.2
37.7
40.6
46.2
48.8
51.4
80.3
65.3
57.9
53.4
50.3
47.5
45.8
44.3
40.2
39.3
37.8
37.2
36.6
78.5
59.6
47.7
38.7
31.4
23.5
18.3
13.2
4.5
0.6
>0*
—
—
70.8
50.8
40.9
34.9
30.8
27.0
24.8
22.8
19.9
18.8
16.8
16.0
15.2
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±22
100±22
100±22
100±22
100±22
20.0
25.0
25.0
25.0
25.0
22.8
21.7
20.5
19.8
19.5
18.4
18.0
17.6
Rip Cord
Third party verified to TIA/EIA-568-B.2-1, Category 6
U.S. Patents 5,606,151; 5,734,126; 5,789,711 and 6,297,454-B1
Jacket sequentially marked at 2 ft. intervals. Features Descending Length Marking.
Non-Plenum • Polyolefin Insulation • Gray Haloarrest® Jacket
7851NH
4
1000
A-1000
304.8
A-304.8
39.0
48.0
17.7
21.8
.241 6.12
x
x
.329 8.36
Rip Cord
Third party verified to TIA/EIA-568-B.2-1, Category 6
U.S. Patents 5,606,151; 5,734,126; 5,789,711 and 6,297,454-B1
Jacket sequentially marked at 1 meter intervals. Features Descending Length Marking.
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Available in Red, Orange, Yellow, Green, Blue, Black, White or Gray)
7852A
NEC:
CMP
CEC:
CMP
4
1000
304.8
A-1000 † A-304.8
Rip Cord
† A-1000
ft. put-up not available in Red.
Third party verified to TIA/EIA-568-B.2-1, Category 6
U.S. Patents 5,606,151; 5,734,126; 5,789,711 and 6,297,454-B1
Jacket sequentially marked at 2 ft. intervals. Features descending Length marking.
40.0
49.0
18.1
22.2
.218 5.54
x
x
.290 7.37
8.2
3.0
65.6
1
10
31.25
62.5
100
155
200
250
350
400
500
550
600
1.9
5.7
10.2
14.7
18.9
23.9
27.5
31.2
37.7
40.6
46.2
48.8
51.4
80.3
65.3
57.9
53.4
50.3
47.5
45.8
44.3
40.2
39.3
37.8
37.2
36.6
78.5
59.6
47.7
38.7
31.4
23.5
18.3
13.2
4.5
0.6
>0*
—
—
70.8
50.8
40.9
34.9
30.8
27.0
24.8
22.8
19.9
18.8
16.8
16.0
15.2
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±22
100±22
100±22
100±22
100±22
20.0
25.0
25.0
25.0
25.0
22.8
21.7
20.5
19.8
19.5
18.4
18.0
17.6
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
*PSUM ACR >0 is guaranteed to 460 MHz
Not RoHS compliant at time of printing. Please check with Belden
Technical Support for current compliance information at 1-800-BELDEN-1.
DataTwist 600e: Beyond Category 6
Belden® DataTwist 600e data cable is a revolutionary UTP cable engineered
specifically to perform well beyond Category 6 standards. While Category 6
cable is specified only to 250 MHz, DataTwist 600e is the only Cat 6 UTP cable
in the industry fully characterized with guaranteed performance to 600 MHz. So
users have far more headroom to compensate for unforeseen factors that can
inhibit the performance of a cabling system today…and protection of their
technology investment for the future.
Color Codes: DataTwist 600e
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Handy Cable Preparation Tool Speeds Installation
Of Bonded-Pair Cables
You know the high performance benefits of using data cables featuring Belden’s
unique Bonded-Pair technology. The Belden Cable Preparation Tool (1797B)
now makes it faster and easier than ever to prepare cables for connector
termination providing special features that help
separate twisted pairs. The Cable Preparation
Tool is packed with every spool of DataTwist
600e. See page 15.40 for more information.
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.47
GigaFlex 4800LX Cable Series
ANSI/TIA/EIA-568-B.2-1, Category 6
Enhanced Category 6 Nonbonded-pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Certified System Cable
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Solid Bare Copper Conductors • Twisted Pairs • Central Cross Web Filler • Rip Cord • See Color Code Chart (below)
White - Reel
Blue - Reel
24586385
24586985
NEC:
CMR
CEC:
CMR
4
1000
304.8
29.1
13.2
.245 6.22
6.6
3.0
50
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0
350.0
400.0
450.0◗
500.0◗
550.0◗
1.7
1.8
3.4
4.8
5.3
6.8
7.6
8.5
9.6
13.8
17.8
26.2
29.7
33.0
36.1
39.0
41.8
44.5
47.1
80.0
78.3
69.3
64.8
63.3
60.3
58.8
57.3
55.9
51.4
48.3
43.8
42.3
41.2
40.2
39.3
38.5
37.8
37.2
78.3
76.5
65.9
60.0
58.0
53.5
51.2
48.8
46.3
37.6
30.5
17.6
12.6
8.2
4.1
0.3
-3.3
-6.7
-9.9
74.0
71.8
59.7
53.7
51.8
47.7
45.7
43.8
41.9
35.8
31.8
25.7
23.8
22.2
20.9
19.7
18.7
17.8
16.9
100±12
100±12
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±22
100±22
100±22
100±22
—
20.0
23.0
25.0
25.0
25.0
25.0
24.6
24.2
23.0
22.1
20.9
20.5
20.2
19.9
19.7
19.5
19.3
19.1
14.1
.246 6.10
6.6
3.0
50
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0
350.0
400.0
450.0◗
500.0◗
550.0◗
1.7
1.8
3.4
4.8
5.3
6.8
7.6
8.5
9.6
13.8
17.8
26.2
29.7
33.0
36.1
39.0
41.8
44.5
47.1
80.0
78.3
69.3
64.8
63.3
60.3
58.8
57.3
55.9
51.4
48.3
43.8
42.3
41.2
40.2
39.3
38.5
37.8
37.2
78.3
76.5
65.9
60.0
58.0
53.5
51.2
48.8
46.3
37.6
30.5
17.6
12.6
8.2
4.1
0.3
-3.3
-6.7
-9.9
74.0
71.8
59.7
53.7
51.8
47.7
45.7
43.8
41.9
35.8
31.8
25.7
23.8
22.2
20.9
19.7
18.7
17.8
16.9
100±12
100±12
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±22
100±22
100±22
100±22
—
20.0
23.0
25.0
25.0
25.0
25.0
24.6
24.2
23.0
22.1
20.9
20.5
20.2
19.9
19.7
19.5
19.3
19.1
13.9
.229 5.81
6.6
3.0
50
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0
350.0
400.0
450.0◗
500.0◗
550.0◗
1.7
1.8
3.4
4.8
5.3
6.8
7.6
8.5
9.6
13.8
17.8
26.2
29.7
33.0
36.1
39.0
41.8
44.5
47.1
80.0
78.3
69.3
64.8
63.3
60.3
58.8
57.3
55.9
51.4
48.3
43.8
42.3
41.2
40.2
39.3
38.5
37.8
37.2
78.3
76.5
65.9
60.0
58.0
53.5
51.2
48.8
46.3
37.6
30.5
17.6
12.6
8.2
4.1
0.3
-3.3
-6.7
-9.9
74.0
71.8
59.7
53.7
51.8
47.7
45.7
43.8
41.9
35.8
31.8
25.7
23.8
22.2
20.9
19.7
18.7
17.8
16.9
100±12
100±12
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±22
100±22
100±22
100±22
—
20.0
23.0
25.0
25.0
25.0
25.0
24.6
24.2
23.0
22.1
20.9
20.5
20.2
19.9
19.7
19.5
19.3
19.1
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
Non-Plenum • Polyolefin Insulation - LSZH Polymer Alloy
Purple - Reel
24588085
NEC:
CMR
CEC:
CMR
4
1000
304.8
31.1
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
Plenum • 100% FEP Insulation - LSZH Polymer Alloy
White - Reel
Blue - Reel
24587385
24587985
NEC:
CMP
CEC:
CMP
4
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
1000
304.8
30.7
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
◗ Values
provided for information only.
Color Codes: GigaFlex 4800LX
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Polyolefin Insulation • PVC Jacket
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.48
MediaTwist UTP Cable
®
TIA/EIA-568-B.2-1, Category 6
Enhanced Category 6 Bonded-Pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Certified System Cable
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Bonded-Pairs Solid Bare Copper Conductor • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Blue, Red, Yellow, Orange, Green, Gold, Purple, White, Black or Gray)
1872A
NEC:
CMR
CEC:
CMR
4
1000
304.8
A-1000 * A-304.8
37.0
37.0
16.8
16.8
.365 9.27
x
x
.165 4.19
9.0
3.0
49.2
Rip Cord
*A-1000 ft. put-up not available in Black.
Features Descending Length Marking.
Jacket sequentially marked at 2 ft. intervals.
U.S. Patents 5,606,151; 5,734,126; 5,821,467
Third party verified to TIA/EIA-568-B.2-1, Category 6
1
4
8
10
16
25
31.25
62.5
100
155
200
250
300
350
400◗
500◗
1.9
3.7
5.3
5.9
7.5
9.5
10.6
15.4
19.8
25.1
29.0
32.8
35.2
39.8
43.0
49.0
72.3
63.3
58.8
57.3
54.3
51.4
49.9
45.4
42.3
39.5
37.8
36.3
35.2
34.2
—
—
70
59
53
51
46
42
39
30
25
14
10
3
>0
—
—
—
64.8
52.8
46.7
44.8
40.7
36.8
34.9
28.9
24.8
20.9
18.8
16.8
15.2
13.9
—
—
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±32
100±32
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
21.0
21.0
21.0
18.0
18.0
17.0
14.0
14.0
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Blue, Natural, Gray, Red, Yellow, Orange, Green, Gold, Purple, White or Black)
1874A
NEC:
CMP
CEC:
CMP
4
1000
304.8
A-1000 ** A-304.8
37.0
38.0
16.8
17.2
.365 9.27
x
x
.165 4.19
9.0
3.0
49.2
Rip Cord
**A-1000 ft. put-up not available in Black.
Features Descending Length Marking.
Jacket sequentially marked at 2 ft. intervals.
U.S. Patents 5,606,151; 5,734,126; 5,821,467
Third party verified to TIA/EIA-568-B.2-1, Category 6
1
4
8
10
16
25
31.25
62.5
100
155
200
250
300
350
400◗
500◗
1.9
3.7
5.3
5.9
7.5
9.5
10.6
15.4
19.8
25.1
29.0
32.8
35.2
39.8
43.0
49.0
72.3
63.3
58.8
57.3
54.3
51.4
49.9
45.4
42.3
39.5
37.8
36.3
35.2
34.2
—
—
70
59
53
51
46
42
39
30
25
14
10
3
>0
—
—
—
64.8
52.8
46.7
44.8
40.7
36.8
34.9
28.9
24.8
20.9
18.8
16.8
15.2
13.9
—
—
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±32
100±32
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
21.0
21.0
21.0
18.0
18.0
17.0
14.0
14.0
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
◗ Values
provided for information only.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
Color Codes: MediaTwist
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Get the Bonded-Pairs
Cable Preparation Tool
See page 15.40 for details.
(Part No. 1797B)
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.49
GigaFlex 2400 Cable Series
TIA/EIA-568-B.2-1, Category 6
Enhanced Category 6 Nonbonded-pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Certified System Cable
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
24566315
24566915
24566345
24566945
NEC:
CMR
CEC:
CMR
4
1000
304.8
26.0
11.8
.214 5.44
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0◗
350.0◗
400.0◗
450.0◗
1.8
2.0
3.7
5.2
5.8
7.4
8.3
9.3
10.4
15.0
19.3
28.3
32.1
35.6
38.9
42.0
45.0
75.0 73.2
73.3 71.3
64.3 60.6
59.8 54.6
58.3 52.5
55.2 47.9
53.8 45.5
52.3 43.1
50.9 40.5
46.4 31.4
43.3 24.0
38.8 10.5
37.3
5.3
36.1
0.5
35.1 -3.7
34.3 -7.7
33.5 -11.5
70.0
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
21.8
19.8
18.3
16.9
15.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
100±32
100±32
100±32
100±32
19.7
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
15.9
15.5
.214 5.44
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0◗
350.0◗
400.0◗
450.0◗
1.8
2.0
3.7
5.2
5.8
7.4
8.3
9.3
10.4
15.0
19.3
28.3
32.1
35.6
38.9
42.0
45.0
75.0 73.2
73.3 71.3
64.3 60.6
59.8 54.6
58.3 52.5
55.2 47.9
53.8 45.5
52.3 43.1
50.9 40.5
46.4 31.4
43.3 24.0
38.8 10.5
37.3
5.3
36.1
0.5
35.1 -3.7
34.3 -7.7
33.5 -11.5
70.0
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
21.8
19.8
18.3
16.9
15.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
100±32
100±32
100±32
100±32
19.7
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
15.9
15.5
.210 5.33
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0
250.0
300.0◗
350.0◗
400.0◗
450.0◗
1.8
2.0
3.7
5.2
5.8
7.4
8.3
9.3
10.4
15.0
19.3
28.3
32.1
35.6
38.9
42.0
45.0
75.0 73.2
73.3 71.3
64.3 60.6
59.8 54.6
58.3 52.5
55.2 47.9
53.8 45.5
52.3 43.1
50.9 40.5
46.4 31.4
43.3 24.0
38.8 10.5
37.3
5.3
36.1
0.5
35.1 -3.7
34.3 -7.7
33.5 -11.5
70.0
67.8
55.8
49.7
47.8
43.7
41.8
39.8
37.9
31.9
27.8
21.8
19.8
18.3
16.9
15.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
100±32
100±32
100±32
100±32
19.7
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
15.9
15.5
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
Non-Plenum • Polyolefin Insulation - LSZH Polymer Alloy
Purple, Reel
24568005
NEC:
CMR
CEC:
CMR
4
1000
304.8
28.0
12.7
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
Plenum • 100% FEP Insulation • Low-Smoke PVC Jacket
White, Reel-in-Box
Blue, Reel-in-Box
White, Reel
Blue, Reel
24567315
24567915
24567345
24567945
NEC:
CMP
CEC:
CMP
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
4
1000
304.8
24.0
10.9
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
◗ Values
provided for information only.
Color Codes: GigaFlex 2400
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Polyolefin Insulation • PVC Jacket
White, Reel-in-Box
Blue, Reel-in-Box
White, Reel
Blue, Reel
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.50
DataTwist 350 UTP Cable
®
TIA/EIA-568-B.2, Category 5e
Enhanced Category 5e Bonded-Pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Certified System Cable
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Bonded-Pairs Solid Bare Copper Conductors • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Red, Orange, White, Black, Yellow, Green, Blue, Purple, Light Gray or Gray)
1700A
NEC:
CM
CEC:
CM
4
1702A*
NEC:
CM
CEC:
CM
2x4
1700R
NEC:
CMR
CEC:
CMR
4
U-1000 U-304.8
304.8
1000 †
500.0
1640 †
†
914.4
3000
†
1000.0
3280
22.0
22.0
36.1
63.0
72.2
10.0
10.0
16.4
28.6
32.8
.200 5.08
304.8
500.0
45.0
73.8
20.4
33.5
.200 5.08
x
x
.415 10.54
U-1000 †† U-304.8
1000 †† 304.8
3000 †† 914.4
22.0
22.0
63.0
10.0
10.0
28.6
.204 5.18
9.0
3.0
66.0
Rip Cord
1000 *
1640 *
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.0
4.0
5.7
6.4
8.1
10.3
11.6
16.8
21.7
27.7
32.0
36.4
44.3
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
63.3
52.3
46.1
43.9
39.1
34.1
31.3
21.6
17.1
4.7
3.0
—
—
60.8
48.8
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±18
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
*1702A is Siamese version of 1700A and is available in Blue or Light Gray only.
† 1000 ft. put-up not available in Gray. 3000 ft. put-up available in Red, Blue, White or Lt. Gray only. 1640 ft. available in Lt. Gray or Blue only. 3280 ft. available in Lt. Gray only.
††1700R is not available in Black nor Medium Gray. 3000 ft. put-up available in Red, Blue, Purple, White or Light Gray only.
Third party verified to TIA/EIA-568-B.2, Category 5e
Jacket sequentially marked at 2 ft. intervals. Features Descending Length Marking. • U.S. Patents 5,606,151 and 5,734,126
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Available in Red, Orange, Gray, Yellow, Green, Blue, Purple, Natural or Black)
1701A
NEC:
CMP
CEC:
CMP
4
1703A**
NEC:
CMP
CEC:
CMP
2x4
U-1000 U-304.8
1000
304.8
914.4
3000 †
23.0
24.0
69.0
10.5
10.9
31.3
.195 4.95
46.0
20.9
.195 4.95
x
x
.405 10.29
9.0
3.0
66.0
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.0
4.0
5.7
6.4
8.1
10.3
11.6
16.8
21.7
27.7
32.0
36.4
44.3
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
63.3
52.3
46.1
43.9
39.1
34.1
31.3
21.6
17.1
4.7
3.0
—
—
60.8
48.8
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±20
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
3.0
66.0
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.0
4.0
5.7
6.4
8.1
10.3
11.6
16.8
21.7
27.7
32.0
36.4
44.3
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
63.3
52.3
46.1
43.9
39.1
34.1
31.3
21.6
17.1
4.7
3.0
—
—
60.8
48.8
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±20
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
Rip Cord
1000 ††
304.8
**1703A is Siamese version of 1701A.
† 3000 ft. put-up available in Blue or Natural only.
†† 1000 ft. put-up available in Blue or Natural only.
Third party verified to TIA/EIA-568-B.2, Category 5e
Jacket sequentially marked at 2 ft. intervals. Features Descending Length Marking. • U.S. Patents 5,606,151 and 5,734,126
Plenum • FEP Teflon Insulation • FEP Jacket (Available in Blue or White)
1701LC
NEC:
Limited
Combustible
FHC 25/50
CMP
CEC:
CMP
4
U-1000
1000
U-304.8
304.8
23.0
24.0
10.5
10.9
.187 4.75
1701LC does not have a rip cord.
Third party verified to TIA/EIA-568-B.2, Category 5e
Jacket sequentially marked at 2 ft. intervals. Features Descending Length Marking. • U.S. Patents 5,606,151 and 5,734,126
9.0
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 350
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Get the Bonded-Pairs
Cable Preparation Tool
See page 15.40 for details.
(Part No. 1797B)
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.51
GigaFlex 1200 Cable Series
TIA/EIA-568-B.2, Category 5E
Enhanced Category 5 Nonbonded-pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Certified System Cable
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
24570166
24570161
24570460
24570452
NEC:
CMR
CEC:
CMR
4
1000
304.8
24.0
10.9
.186 4.72
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0◗
250.0◗
300.0◗
350.0◗
1.8
2.0
4.0
5.7
6.3
8.1
9.1
10.2
11.5
16.7
21.6
31.9
36.3
40.3
44.2
69.0 67.2
67.3 65.3
58.3 54.3
53.8 48.1
52.3 46.0
49.3 41.2
47.8 38.7
46.3 36.1
44.9 33.4
40.4 23.7
37.3 15.7
32.8
0.9
31.3 -4.9
30.2 -10.2
29.2 -15.0
63.0
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
14.7
12.8
11.2
9.9
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±22
100±22
100±22
—
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
.198 5.03
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0◗
250.0◗
300.0◗
350.0◗
1.8
2.0
4.0
5.7
6.3
8.1
9.1
10.2
11.5
16.7
21.6
31.9
36.3
40.3
44.2
69.0 67.2
67.3 65.3
58.3 54.3
53.8 48.1
52.3 46.0
49.3 41.2
47.8 38.7
46.3 36.1
44.9 33.4
40.4 23.7
37.3 15.7
32.8
0.9
31.3 -4.9
30.2 -10.2
29.2 -15.0
63.0
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
14.7
12.8
11.2
9.9
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±22
100±22
100±22
—
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
200.0◗
250.0◗
300.0◗
350.0◗
1.8
2.0
4.0
5.7
6.3
8.1
9.1
10.2
11.5
16.7
21.6
31.9
36.3
40.3
44.2
69.0 67.2
67.3 65.3
58.3 54.3
53.8 48.1
52.3 46.0
49.3 41.2
47.8 38.7
46.3 36.1
44.9 33.4
40.4 23.7
37.3 15.7
32.8
0.9
31.3 -4.9
30.2 -10.2
29.2 -15.0
63.0
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
14.7
12.8
11.2
9.9
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±22
100±22
100±22
—
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.0
17.3
16.8
16.3
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2, Category 5e
Non-Plenum • Polyolefin Insulation - LSZH Polymer Alloy
Purple
24570157
NEC:
CMR
CEC:
CMR
4
1000
304.8
25.0
11.3
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2, Category 5e
Plenum • Dual Insulation: Polyolefin / FEP • Low-Smoke PVC Jacket
White, Box
Blue, Box
White, Reel
Blue, Reel
24570810
24570800
24570808
24570812
NEC:
CMP
CEC:
CMP
Rip Cord
4
1000
304.8
22.0
9.98
.188 4.78
9.38
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-B.2, Category 5e
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
◗ Values
provided for information only.
Color Codes: GigaFlex 1200
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Polyolefin Insulation • PVC Jacket
White, Box
Blue, Box
White, Reel
Blue, Reel
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.52
DataTwist 6 UTP Cable
®
TIA/EIA-568-B.2-1, Category 6 Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Solid Bare Copper Conductors • Twisted Pairs • Central Rod Filler • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Gray, White or Black)
7881A
NEC:
CMR
CEC:
CMR
4
1000
A-1000
304.8
A-304.8
30.0
33.0
13.6
15.0
.241 6.12
8.2
5.0
330
Rip Cord
1
10
20
31.25
62.5
100
200
250
2.0
6.0
8.5
10.7
15.4
19.8
29.0
32.8
72.3
57.3
52.8
49.9
45.4
42.3
37.8
36.3
70.3
51.3
44.3
39.2
30.0
22.5
8.8
3.5
64.8
44.8
38.8
34.9
28.9
24.8
18.8
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
20.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
Jacket sequentially marked at 2 ft. intervals.
Features Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
Plenum • Dual FRPO/FEP Insulation • Flamarrest® Jacket (Avail. in Red, Orange, Yellow, Green, Blue, Purple, Gray, Natural or Black)
7882A
NEC:
CMP
CEC:
CMP
4
Rip Cord
1000
A-1000
304.8
A-304.8
29.0
32.0
13.2
14.5
.224 5.69
8.2
5.0
330
1
10
20
31.25
62.5
100
200
250
2.0
6.0
8.5
10.7
15.4
19.8
29.0
32.8
72.3
57.3
52.8
49.9
45.4
42.3
37.8
36.3
70.3
51.3
44.3
39.2
30.0
22.5
8.8
3.5
64.8
44.8
38.8
34.9
28.9
24.8
18.8
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
20.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
Jacket sequentially marked at 2 ft. intervals.
Features Descending Length Marking.
Third party verified to TIA/EIA-568-B.2-1, Category 6
ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • FEP = Fluorinated Ethylene Propylene • FRPO = Flame-retardant Polyolefin •
NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
For either T568-A or T568-B configurations.
Color Codes: DataTwist 6
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.53
DataTwist 6 Limited Combustible UTP Cable
TIA/EIA 568-B.2-1, Category 6
Enhanced Category 6 Bonded-Pair Cables
Part
No.
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Bonded-Pairs • Solid Bare Copper Conductors • Twisted Pairs • Central Rod Filler • Rip Cord • See Color Code Chart (below)
Plenum • FEP Teflon® Insulation • FEP Jacket (Available in Light Blue or White)
NEC:
Limited
Combustible
FHC 25/50
CMP
CEC:
CMP
Rip Cord
Jacket sequentially marked at 2 ft. intervals.
Features Descending Length Marking.
Third party verified to TIA/EIA 568-B.2-1, Category 6
U.S. Patents 5,606,151 and 5,734,126
4
1000
U-1000
304.8
U-304.8
35.0
33.0
15.89
14.98
.214 5.44
8.2
5.0
330
1
4
8
10
16
20
25
31.25
62.5
100
155
200
250
2.0
3.8
5.3
6.0
7.6
8.5
9.5
10.7
15.4
19.8
25.2
29.0
32.8
72.3
63.3
58.8
57.3
54.3
52.8
51.3
49.9
45.4
42.3
39.5
37.8
36.3
70.3
59.5
53.4
51.3
46.7
44.3
41.8
39.2
30.0
22.5
14.3
8.8
3.5
64.8
52.8
46.7
44.8
40.7
38.8
36.8
34.9
28.9
24.8
20.9
18.8
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±22
100±32
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
18.8
18.0
17.3
ACR = Attenuation Crosstalk Ratio • ELFEXT = Equal Level Far-end Crosstalk • FEP = Fluorinated Ethylene Propylene • NEXT = Near-end Crosstalk • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Teflon is a DuPont trademark.
Color Codes: DataTwist 6 LC
Pair No.
Color Combination
1
White/Blue Stripe, Blue
2
White/Orange Stripe, Orange
3
White/Green Stripe, Green
4
White/Brown Stripe, Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
7813LC
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.54
DataTwist 5e+ UTP Cable
®
TIA/EIA-568-B.2, Category 5e
Enhanced Category 5e Nonbonded-Pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Gray or White)
Rip Cord
1500A
NEC:
CM
CEC:
CM
4
1000
A-1000
304.8
A-304.8
23.0
26.0
10.4
11.8
.190 4.83
1500R
NEC:
CMR
CEC:
CMR
4
1000
A-1000
304.8
A-304.8
24.0
27.0
10.9
12.3
.194 4.93
9.0
3.0
200
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.0
4.0
5.7
6.4
8.1
10.3
11.6
16.8
21.7
27.7
32.0
36.4
44.3
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
63.3
52.3
46.1
43.9
39.1
34.1
31.3
21.6
17.1
4.7
3.0
—
—
60.8
48.7
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±20
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
Jacket sequentially marked at 2 ft. intervals
Features Descending Length Marking.
Third party verified to TIA/EIA-568-B.2, Category 5e
Plenum • Dual FRPO/FEP Insulation • Flamarrest® Jacket (Avail. in Red, Orange, Yellow, Green, Blue, Gray, White or Natural)
1501A
NEC:
CMP
CEC:
CMP
4
Rip Cord
†1000 ft. put-up not available in Red.
Jacket sequentially marked at 2 ft. intervals
Features Descending Length Marking..
Third party verified to TIA/EIA-568-B.2, Category 5e
1000 †
304.8
A-1000 A-304.8
23.0
26.0
10.4
11.8
.190 4.83
9.0
3.0
200
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.0
4.0
5.7
6.4
8.1
10.3
11.6
16.8
21.7
27.7
32.0
36.4
44.3
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
63.3
52.3
46.1
43.9
39.1
34.1
31.3
21.6
17.1
4.7
3.0
—
—
60.8
48.7
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±20
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • FEP = Fluorinated Ethylene Propylene • FRPO = Flame-retardant Polyolefin • NEXT = Near-end Crosstalk •
PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 5e+
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Get the Bonded-Pairs
Cable Preparation Tool
See page 15.40 for details.
(Part No. 1797B)
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.55
DataTwist 350 Composite UTP Cable
ANSI/TIA/EIA 568-B.2, Category 5e
Banana Peel Jacketless Cables
®
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Bonded-Pairs • Solid Bare Copper Conductors • Spline Filler • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Inner Jacket (Available in Light Blue or Gray) • No Overall Jacket
1700S6
NEC:
CMR
CEC:
CMG
24
500
1000
152.4
304.8
77.5
149.0
35.19
67.65
.204 5.18
9.0
3.0
66.0
Bundled:
.600 15.24
1
10
16
31.25
62.5
100
200
250
350
2.0
6.4
8.1
11.6
16.8
21.7
32.0
36.4
44.3
65.3
50.3
47.3
42.9
38.4
35.3
30.8
29.3
27.2
63.3
43.9
39.1
31.3
21.6
17.1
3.0
>0.0
—
60.8
40.8
36.7
30.9
24.9
20.8
14.7
12.8
9.9
100±12
100±12
100±12
100±15
100±15
100±15
100±20
100±20
100±22
20.0
25.0
25.0
23.6
21.5
20.1
19.0
18.0
17.0
63.3
43.9
39.1
31.3
21.6
17.1
3.0
>0.0
—
60.8
40.8
36.7
30.9
24.9
20.8
14.7
12.8
9.9
100±12
100±12
100±12
100±15
100±15
100±15
100±20
100±20
100±22
20.0
25.0
25.0
23.6
21.5
20.1
19.0
18.0
17.0
Bundled version of 1700R.
U.S. Patents 5,606,151; 5,734,126; 7,049,523.
Individual leg is third party verified to ANSI/TIA/EIA 568-B.2, Category 5e
1701S6
NEC:
CMP
CEC:
CMP
24
500
1000
152.4
304.8
81.5
157.0
37.00
71.28
.195 4.95
Bundled:
.600 15.24
9.0
3.0
66.0
1
10
16
31.25
62.5
100
200
250
350
2.0
6.4
8.1
11.6
16.8
21.7
32.0
36.4
44.3
65.3
50.3
47.3
42.9
38.4
35.3
30.8
29.3
27.2
Bundled version of 1701A.
U.S. Patents 5,606,151; 5,734,126; 7,049,523.
Individual leg is third party verified to ANSI/TIA/EIA 568-B.2, Category 5e
UTP = Unshielded Twisted Pair(s) • NEXT = Near-end Crosstalk • ACR = Attenuation Crosstalk Ratio • ELFEXT = Equal Level Far-end Crosstalk • RL = Return Loss
Color Codes: DT 350 Composite
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • FEP Insulation • Flamarrest® Inner Jacket (Available in Blue or Natural) • No Overall Jacket
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.56
DataTwist 5e UTP Cable
®
TIA/EIA-568-B.2, Category 5e Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.9
20.8
14.7
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Dark Gray or Blue)
Rip Cord
1588A
NEC:
CM
CEC:
CM
2
U-1000 U-304.8
1000
304.8
500.0
1640 †
14.0
15.0
24.6
6.4
6.8
11.2
.183 4.65
1588R
NEC:
CMR
CEC:
CMR
2
U-1000 †† U-304.8
1000 †† 304.8
14.0
15.0
6.4
6.8
.183 4.65
9.38
5.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
†
1640 ft. put-up available in Dark Gray only.
U-1000 ft. and 1000 ft. put-ups available in Blue only
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
††
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in White, Black, Gray, Blue, Red, Orange, Yellow, Green or Pink)
Rip Cord
1583A
NEC:
CM
CEC:
CM
4
U-1000 U-304.8
1000
304.8
500.0
1640 †
†
914.4
3000
21.0
21.0
34.4
63.0
9.5
9.5
15.7
28.6
.195 4.95
1583R
NEC:
CMR
CEC:
CMR
4
U-1000 †† U-304.8
1000 †† 304.8
3000 †† 914.4
22.0
22.0
63.0
10.0
10.0
28.6
.197 5.00
9.38
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.9
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.9
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
†
1640 ft. put-up available in Dark Gray or Blue only. 3000 ft. put-up available in Dark Gray, White or Blue only.
1583R is not available in Black. 3000 ft. put-ups available in Dark Gray, White or Blue only.
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
††
Non-Plenum • Polyolefin Insulation • Fluorescent Pink PVC Jacket
DataBrite®
1583B
NEC:
CMR
CEC:
CMR
4
U-1000
1000
U-304.8
304.8
19.0
20.0
8.6
9.1
.195 4.95
9.38
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
Non-Plenum • Polyolefin Insulation • UV Resistant PVC Jacket (Available in Gray, White or Ivory)
Indoor/Outdoor
1594A
NEC:
CMR/CMX
CEC:
CMR/CMX
4
U-1000
U-304.8
26.0
11.8
.220 5.58
9.38
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.9
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
66.0
1
4
10
16
31.25
62.5
100
200
2.0
4.0
6.4
8.1
11.4
16.4
21.0
30.5
68.3
59.3
53.3
50.2
45.9
41.4
38.3
33.8
66.3
55.3
46.9
42.1
34.5
25.0
17.3
3.3
64.8
52.8
44.8
40.7
34.9
28.9
24.8
18.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
20.0
23.0
25.0
25.0
23.6
21.5
20.1
18.0
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
Outside Plant • Polyolefin Insulation • Black Gel-filled Polyethylene Jacket
Outdoor
7997A
4
1000
304.8
38.0
Rip Cord
17.2
.251 6.38
8.90
3.0
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 5e
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.57
DataTwist 5e UTP Cable
®
TIA/EIA-568-B.2, Category 5e Nonbonded-Pair Cables
Part
No.
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
40.8
36.7
30.9
24.8
20.8
14,7
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Available in Natural or Blue)
1590A
NEC:
CMP
CEC:
CMP FT6
2
1000
304.8
16.0
7.3
.175 4.44
9.38
5.0
330
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
1
10
16
31.25
62.5
100
200
2.0
6.5
8.2
11.7
17.0
22.0
32,0
62.3
47.3
44.3
39.9
35.4
32.3
27,8
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
25.0
25.0
23.6
21.5
20.1
15,0
1585A
NEC:
CMP
CEC:
CMP FT6
4
U-1000 U-304.8
1000
304.8
914.6
3000 †
23.0
24.0
69.0
10.5
10.9
31.4
.198 5.03
9.38
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
3.0
330
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.0
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40,8
36.0
28.2
19.0
10,3
1.0
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
Rip Cord
† 3000
ft. put-up available in Natural or Blue only.
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
Plenum • FEP Teflon Insulation • Fluorescent Pink Flamarrest Jacket
DataBrite®
1585B
NEC:
CMP
CEC:
CMP FT6
4
1000
304.8
24.0
10.9
.197 5.00
9.38
Rip Cord
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-B.2, Category 5e
Plenum • FEP Teflon Insulation • FEP Jacket (Available in Blue or White)
1585LC
NEC:
Limited
Combustible
FHC 25/50
CMP
CEC:
CMP FT6
4
U-1000
1000
U-304.8
304.8
23.0
23.0
10.5
10.5
.195 4.95
9.38
Jacket sequentially marked at 2 ft. intervals. No rip cord.
Third party verified to TIA/EIA-568-B.2, Category 5e
Patch Cable • 24 AWG Stranded (7x32) Bare Copper Conductors • Twisted Pairs • RJ-45 Compatible* • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Light Gray, White or Black)
Patch Cable
1592A
NEC:
CM
CEC:
CM FT1
4
U-1000
1000
U-304.8
304.8
22.0
23.0
10.0
10.5
.213 5.41
9.38
3.0
330
1
4
10
16
31.25
62.5
100
200
2.5
4.9
7.8
9.9
14.1
20.4
26.4
38.9
62.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
—
—
—
—
—
—
—
—
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
*RJ-45 compatible for either T568-A or T568-B configurations.
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e Patch
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • FEP = Fluorinated Ethylene Propylene • NEXT = Near-end Crosstalk • PSUM = Power Sum •
RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 5e
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Red, Orange, Yellow, Green, Gray, White, Black, Pink, Natural or Blue)
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.58
IBDN Plus 25-Pair Cat5E UTP Cable
TIA/EIA-568-B.2, Category 5E
Enhanced Category 5 Nonbonded-pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max.
Min.
Cap. Freq. Atten. PSUM
Unbal.
NEXT
(MHz) (dB/
(pF/
100m)
100m)
(dB)
Min.
PSUM
ELFEXT
(dB/
100m)
Input
Imped.
(Ω)
Min.
RL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • Gray PVC Jacket
Gray, Reel
24576125
NEC:
CMR
CEC:
CMR
25
1000
304.8
119
54.0
.490 12.45 9.38
—
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
1.8
2.0
4.1
15.8
16.5
8.2
9.3
10.4
11.7
17.0
22.0
64,0
62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3
63.0
63.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8
102±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
19.4
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
.430 10.90 9.38
—
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
1.8
2.0
4.1
15.8
16.5
8.2
9.3
10.4
11.7
17.0
22.0
64,0
62.3
53.3
48.8
47.3
44.2
42.8
41.3
39.9
35.4
32.3
63.0
63.8
48.8
42.7
40.8
36.7
34.8
32.8
30.9
24.9
20.8
102±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
19.4
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Third party verified to TIA/EIA-568-B.2, Category 5e
Plenum • FEP Insulation • Gray Low-smoke PVC Jacket
Gray, Reel
24577125
NEC:
CMP
CEC:
CMP
Rip Cord
25
1000
304.8
127
57.6
Jacket sequentially market at 2 ft. intervals.
Third party verified to TIA/EIA-568-B.2, Category 5e
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes:
IBDN Plus 25-Pair Cat5
Pair No.
Tip
Ring
1
White
Blue
2
White
Orange
3
White
Green
4
White
Brown
5
White
Slate
6
Red
Blue
7
Red
Orange
8
Red
Green
9
Red
Brown
10
Red
Slate
11
Black
Blue
12
Black
Orange
13
Black
Green
14
Black
Brown
15
Black
Slate
16
Yellow
Blue
17
Yellow
Orange
18
Yellow
Green
19
Yellow
Brown
20
Yellow
Slate
21
Violet
Blue
22
Violet
Orange
23
Violet
Green
24
Violet
Brown
25
Violet
Slate
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.59
IBDN Plus 25-Pair Cat5 UTP Cable
TIA/EIA-568-A, Category 5
Category 5 Nonbonded-pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • Blue PVC Jacket
Blue, Reel
Blue, Reel
Blue,, Reel
24572238
24572250
24572260
NEC:
CMR
CEC:
CMR
25
25
25
1000
492
500
304.8
150.0
152.4
118.0
53.5
4.90 124.5 9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
1.8
2.1
4.3
5.9
6.6
8.2
9.2
10.5
11.8
17.1
22.0
64.0
62.0
53.0
48.0
47.0
44.0
42.0
41.0
40.0
35.0
32.0
102±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23
23
23
23
23
23
22
21
18
16
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
1.8
2.1
4.3
5.9
6.6
8.2
9.2
10.5
11.8
17.1
22.0
64.0
62.0
53.0
48.0
47.0
44.0
42.0
41.0
40.0
35.0
32.0
102±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23
23
23
23
23
23
22
21
18
16
Rip Cord
Plenum • 100% FEP Insulation • Gray Low-Smoke PVC Jacket
Gray, Reel
Gray, Reel
Gray, Reel
24572351
24572352
24572353
NEC:
CMP
CEC:
CMP
25
25
25
328
984
1000
100.0
300.0
304.8
118.0
53.5
4.90 124.5 9.38
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 5
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes:
IBDN Plus 25-Pair Cat5
Pair No.
Tip
Ring
1
White
Blue
2
White
Orange
3
White
Green
4
White
Brown
5
White
Slate
6
Red
Blue
7
Red
Orange
8
Red
Green
9
Red
Brown
10
Red
Slate
11
Black
Blue
12
Black
Orange
13
Black
Green
14
Black
Brown
15
Black
Slate
16
Yellow
Blue
17
Yellow
Orange
18
Yellow
Green
19
Yellow
Brown
20
Yellow
Slate
21
Violet
Blue
22
Violet
Orange
23
Violet
Green
24
Violet
Brown
25
Violet
Slate
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Jacket sequentially market at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 5
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.60
Data Grade Armored Riser 25-Pair UTP Cable
TIA/EIA-568-A, Category 5
Category 5 Nonbonded-pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Flame Retardant Polymer Insulation • ALVYAN Sheath • PVC Jacket
Gray, Reel
Gray, Reel
25500027
25500028
NEC:
CMR
CEC:
CMR
25
25
8200
2500
Cut Length
205.0
93.0
0.62 15.70 9.38
—
328
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
1.8
2.1
4.3
5.9
6.6
8.2
9.2
10.5
11.8
17.1
22.0
64.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
40.9
35.4
32.3
102±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23
23
23
23
23
23
22
21
18
16
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 5
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: Data Grade Riser
Pair No.
Tip
Ring
1
White
Blue
2
White
Orange
3
White
Green
4
White
Brown
5
White
Slate
6
Red
Blue
7
Red
Orange
8
Red
Green
9
Red
Brown
10
Red
Slate
11
Black
Blue
12
Black
Orange
13
Black
Green
14
Black
Brown
15
Black
Slate
16
Yellow
Blue
17
Yellow
Orange
18
Yellow
Green
19
Yellow
Brown
20
Yellow
Slate
21
Violet
Blue
22
Violet
Orange
23
Violet
Green
24
Violet
Brown
25
Violet
Slate
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.61
DataTwist 5 UTP Cable
®
TIA/EIA-568-A, Category 5 Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
Nominal
OD
kg
Inch
mm
Max.
DCR
Unbal.
(Ω/
100m)
(%)
Max.
DCR
Max.
Max. Min. Fitted
Cap. Freq. Atten. PSUM Input
Unbal.
(dB/
NEXT Imped.
(MHz)
(pF/
(dB)
100m)
(Ω)
100m)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Light Gray or Blue)
1864A
NEC:
CMR
CEC:
CMR FT4
25
1000
304.8
144.0
65.4
.526
13.36
9.38
5.0
330
1
10
16
31.25
62.5
100
2.0
6.5
8.2
11.7
17.0
22.0
62.3
47.3
44.3
39.9
35.4
32.3
100±15
100±15
100±15
100±15
100±15
100±15
23.0
23.0
23.0
21.1
18.0
16.0
5.0
330
1
10
16
31.25
62.5
100
2.0
6.5
8.2
11.7
17.0
22.0
62.3
47.3
44.3
39.9
35.4
32.3
100±15
100±15
100±15
100±15
100±15
100±15
23.0
23.0
23.0
21.1
18.0
16.0
Rip Cord
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 5
1871A
NEC:
CMP
CEC:
CMP
25
1000
304.8
131.0
59.5
.430
10.92
9.38
Rip Cord
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 5
DCR = DC Resistance • NEXT = Near-end Crosstalk • PSUM = Power Sum • SRL = Structural Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: 1864A
Pair
Color Codes: 1871A
Color Combination
Pair
Color Combination
Pair
Color Combination
Pair
Color Combination
1
White & Blue
14
Black & Brown
1
White/Blue Stripe & Blue
14
Black/Brown Stripe & Brown
2
White & Orange
15
Black & Gray
2
White/Orange Stripe & Orange
15
Black/Gray Stripe & Gray
3
White & Green
16
Yellow & Blue
3
White/Green Stripe & Green
16
Yellow/Blue Stripe & Blue
4
White & Brown
17
Yellow & Orange
4
White/Brown Stripe & Brown
17
Yellow/Orange Stripe & Orange
5
White & Gray
18
Yellow & Green
5
White/Gray Stripe & Gray
18
Yellow/Green Stripe & Green
6
Red & Blue
19
Yellow & Brown
6
Red/Blue Stripe & Blue
19
Yellow/Brown Stripe & Brown
7
Red & Orange
20
Yellow & Gray
7
Red/Orange Stripe & Orange
20
Yellow/Gray Stripe & Gray
8
Red & Green
21
Purple & Blue
8
Red/Green Stripe & Green
21
Purple/Blue Stripe & Blue
9
Red & Brown
22
Purple & Orange
9
Red/Brown Stripe & Brown
22
Purple/Orange Stripe & Orange
10
Red & Gray
23
Purple & Green
10
Red/Gray Stripe & Gray
23
Purple/Green Stripe & Green
11
Black & Blue
24
Purple & Brown
11
Black/Blue Stripe & Blue
24
Purple/Brown Stripe & Brown
12
Black & Orange
25
Purple & Gray
12
Black/Orange Stripe & Orange
25
Purple/Gray Stripe & Gray
13
Black & Green
13
Black/Green Stripe & Green
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • FEP Teflon® Insulation • FEP Jacket (Available in Blue Tint or White Tint)
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.62
IBDN Plus UTP Cable
TIA/EIA-568-A, Category 5
Category 5 Nonbonded-pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Min.
PSUM
ACR
(dB/
100m)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket
White, Box
Blue, Box
24570086
24570036
NEC:
CMR
CEC:
CMR
4
1000
304.8
10.9
24.0
.186 4.72
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
155.0◗
1.8
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
28.1
64.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
29.5
62.2
60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3
1.4
—
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23.0
23.0
23.0
23.0
23.0
23.0
22.0
21.1
18.1
16.0
14.1
.198 5.03
9.38
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
155.0◗
1.8
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
28.1
64.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
29.5
62.2
60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3
1.4
—
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23.0
23.0
23.0
23.0
23.0
23.0
22.0
21.1
18.1
16.0
14.1
5.0
330
0.772
1.0
4.0
8.0
10.0
16.0
20.0
25.0
31.25
62.5
100.0
155.0◗
1.8
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
28.1
64.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
29.5
62.2
60.3
49.2
43.0
40.8
36.0
33.5
30.9
28.2
18.4
10.3
1.4
—
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
—
23.0
23.0
23.0
23.0
23.0
23.0
22.0
21.1
18.1
16.0
14.1
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 5
Non-Plenum • Polyolefin Insulation • LSZH Polymer Alloy
Purple, Box
24570152
NEC:
CMR
CEC:
CMR
4
1000
304.8
11.3
25.0
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 5
Plenum • Dual Insulation: Polyolefin/FEP • Low-Smoke PVC Jacket
White, Box
Blue, Box
24570700
24570750
NEC:
CMP
CEC:
CMP
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 5
4
1000
304.8
9.98
22.0
.188 4.78
9.38
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
◗ Values
provided for information only.
Color Codes: IBDN Plus
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.63
DataTwist 3 UTP Cable
®
TIA/EIA-568-A, Category 3 Nonbonded-Pair Cables
Part
No.
Description
UL NEC/
No.
C(UL) CEC
of
Type
Pairs
Standard Lengths
Ft.
m
Standard
Unit Weight
Lbs.
kg
Nominal
OD
Inch
mm
Nominal
Nominal Nom. Capacitance Freq.
Imped.
DCR
(MHz)
*
*
(Cond.)
(Ω) pF/Ft.
pF/m
Min.
NEXT
(dB)
Maximum
Attenuation
(dB/
(dB/
1000′) 100m)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • Gray PVC Jacket
1227A1
NEC:
CMR
CEC:
CMR
2
U-1000
U-304.8 13.0
6.0
.173
4.39 28.0Ω/M′
91.8Ω/km
1229A1
NEC:
CMR
CEC:
CMR
4
U-1000
U-304.8 22.0
10.0
.197
5.00
1232A1
NEC:
CMR
CEC:
CMR
25 †
1000
304.8 104.0
47.2
.399 10.14
100
19.0
62.3
1
4
10
16
41.0
32.0
26.0
23.0
7.8
17.0
30.0
40.0
2.56
5.58
9.71
13.10
100
19.0
62.3
1
4
10
16
41.0
32.0
26.0
23.0
7.8
17.0
30.0
40.0
2.56
5.58
9.71
13.10
˜
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 3
Plenum • Low-Smoke PVC Insulation • White Low-Smoke PVC Jacket
1243A2
NEC:
CMP
CEC:
CMP
2
U-1000
U-304.8 14.0
6.4
.170
4.32 28.0Ω/M′
91.8Ω/km
1245A2
NEC:
CMP
CEC:
CMP
4
U-1000
U-304.8 23.0
10.4
.200
5.08
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 3
DCR = DC Resistance • NEXT = Near-end Crosstalk • UTP = Unshielded Twisted Pair(s)
*Capacitance between conductors
† 25-pair NEXT is Power Sum tested.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
Color Codes: DataTwist 3
Pair No.
Color Combination
Pair No.
Color Combination
1
White/Blue Stripe & Blue/White Stripe
14
Black/Brown Stripe & Brown/Black Stripe
2
White/Orange Stripe & Orange/White Stripe
15
Black/Gray Stripe & Gray/Black Stripe
3
White/Green Stripe & Green/White Stripe
16
Yellow/Blue Stripe & Blue/Yellow Stripe
4
White/Brown Stripe & Brown/White Stripe
17
Yellow/Orange Stripe & Orange/Yellow Stripe
5
White/Gray Stripe & Gray/White Stripe
18
Yellow/Green Stripe & Green/Yellow Stripe
6
Red/Blue Stripe & Blue/Red Stripe
19
Yellow/Brown Stripe & Brown/Yellow Stripe
7
Red/Orange Stripe & Orange/Red Stripe
20
Yellow/Gray Stripe & Gray/Yellow Stripe
8
Red/Green Stripe & Green/Red Stripe
21
Purple/Blue Stripe & Blue/Purple Stripe
9
Red/Brown Stripe & Brown/Red Stripe
22
Purple/Orange Stripe & Orange/Purple Stripe
10
Red/Gray Stripe & Gray/Red Stripe
23
Purple/Green Stripe & Green/Purple Stripe
11
Black/Blue Stripe & Blue/Black Stripe
24
Purple/Brown Stripe & Brown/Purple Stripe
12
Black/Orange Stripe & Orange/Black Stripe
25
Purple/Gray Stripe & Gray/Purple Stripe
13
Black/Green Stripe & Green/Black Stripe
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
˜
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.64
D-Inside and D-Flex Plenum UTP Cable
TIA/EIA-568-A and CSA T529-95, Category 3
Category 3 Nonbonded-pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyvinyl Chloride Insulation • Olive Gray Low-Smoke PVC Jacket
Olive Gray, Box
Olive Gray, Box
Olive Gray, Box
Olive Gray, Box
Olive Gray, Reel
24501922
24501934
24501941
24501950
24501947
NEC:
CMR
CEC:
CMR
2
3
4
4
4
2500
1500
1000
1500
1000
762.0
457.2
304.8
457.2
304.8
11.0
15.0
18.0
18.0
18.0
4.99
6.80
8.16
8.16
8.16
0.13
0.15
0.17
0.17
0.17
3.30
3.90
4.30
4.30
4.30
9.38
5.0
262
0.772
1.0
4.0
8.0
10.0
16.0
2.2
2.6
5.6
8.5
9.7
13.1
43.0
41.0
32.0
28.0
26.0
23.0
—
100±15
100±15
100±15
100±15
100±15
—
12.0
12.0
12.0
12.0
10.0
2.2
2.6
5.6
8.5
9.7
13.1
43.0
41.0
32.0
28.0
26.0
23.0
—
100±15
100±15
100±15
100±15
100±15
—
12.0
12.0
12.0
12.0
10.0
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 3
Plenum • Low Smoke Polyvinyl Chloride Insulation • Olive Gray Low-Smoke Jacket
Olive Gray, Box
Olive Gray, Box
Olive Gray, Box
Olive Gray, Reel
24571097
24571111
24571112
24571110
NEC:
CMP
CEC:
CMP
3
4
4
4
1500
1000
1500
1000
457.2
304.8
457.2
304.8
16.0
19.0
19.0
19.0
7.26
8.62
8.62
8.62
0.16
0.19
0.19
0.19
4.06
4.70
4.70
4.70
9.38
5.0
262
0.772
1.0
4.0
8.0
10.0
16.0
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 3
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: D-Inside and D-Flex
Pair No.
Color Combination
1
White/Blue Stripe & Blue/White Stripe
2
White/Orange Stripe & Orange/White Stripe
3
White/Green Stripe & Green/White Stripe
4
White/Brown Stripe & Brown/White Stripe
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.65
D-Series Multipair UTP Cable
TIA/EIA-568-A and CSA T529-95, Category 3
Category 3 Nonbonded-pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
24501829
24501837
24501848
24501858
24501877
24501887
24501897
24501906
NEC:
CMR
CEC:
CMR
6
12
16
25
50
75
100
200
1000
1000
984
1000
1000
2083
1575
900
304.8
304.8
300.0
304.8
304.8
635.0
480.0
274.3
28.0
50.0
64.0
100.0
194.0
279.0
365.0
703.0
12.7
22.7
29.0
45.4
87.0
126.6
165.6
318.9
0.21
0.28
0.32
0.39
0.53
0.63
0.72
0.99
5.3
7.1
8.0
10.0
13.4
16.0
18.2
25.1
—
8.8
262
0.772
1.0
4.0
8.0
10.0
16.0
2.2
2.6
5.6
8.5
9.7
13.1
43.0
41.0
32.0
28.0
26.0
23.0
100±15
100±15
100±15
100±15
100±15
100±15
12.0
12.0
12.0
12.0
12.0
10.0
43.0
41.0
32.0
28.0
26.0
23.0
100±15
100±15
100±15
100±15
100±15
100±15
12.0
12.0
12.0
12.0
12.0
10.0
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 3
Plenum • Low Smoke Polyvinyl Chloride Insulation • Low-Smoke PVC Jacket (Gray or Translucent)
Translucent, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
24571221
24571235
24571250
24571265
24571266
NEC:
CMP
CEC:
CMP
25
50
100
200
300
1500
1000
1500
1000
1000
457.2 107.0
304.8 211.0
457.2 415.0
304.8 874.0
304.8 1234.0
48.5
95.7
188.2
396.4
559.7
0.42
0.49
0.72
1.04
1.27
10.7
12.4
18.3
26.3
32.3
—
8.8
262
0.772
1.0
4.0
8.0
10.0
16.0
2.2
2.6
5.6
8.5
9.7
13.1
Rip Cord
Jacket sequentially market at 2 ft. intervals.
Featuring Descending Length Marking.
Third party verified to TIA/EIA-568-A, Category 3
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: D-Series Multipair
Pair No.
Tip
Ring
Tip
Ring
1
White/Blue
Blue/White
Pair No.
14
Black/Brown
Brown/Black
2
White/Orange
Orange/White
15
Black/Slate
Slate/Black
3
White/Green
Green/White
16
Yellow/Blue
Blue/Yellow
4
White/Brown
Brown/White
17
Yellow/Orange
Orange/Yellow
5
White/Slate
Slate/White
18
Yellow/Green
Green/Yellow
6
Red/Blue
Blue/Red
19
Yellow/Brown
Brown/Yellow
7
Red/Orange
Orange/Red
20
Yellow/Slate
Slate/Yellow
8
Red/Green
Green/Red
21
Violet/Blue
Blue/Violet
9
Orange/Violet
Red/Brown
Brown/Red
22
Violet/Orange
10
Red/Slate
Slate/Red
23
Violet/Green
Green/Violet
11
Black/Blue
Blue/Black
24
Violet/Brown
Brown/Violet
12
Black/Orange
Orange/Black
25
Violet/Slate
Slate/Violet
13
Black/Green
Green/Black
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Semi-Rigid Polyvinyl Chloride Insulation • Olive Gray PVC Jacket
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
Olive Gray, Reel
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.66
Riser Multipair Armored UTP Cable
TIA/EIA-568-A and CSA T529-95, Category 3
Category 3 Nonbonded-pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
102±15
102±15
102±15
102±15
102±15
102±15
12.0
12.0
12.0
12.0
12.0
10.0
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Dual Insulation: Polyolefin/PVC • ALVYAN Sheath • Gray PVC Jacket
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
Gray, Reel
22713010
22713020
22713030
22713035
22713040
22713045
22713050
22713060
22713070
22713080
22713090
NEC:
CMR
CEC:
CMR
25
50
100
105
200
250
300
400
600
900
1200
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
Variable Length
132.0
239.0
421.0
610.0
766.0
940.0
1111.0
1453.0
2146.0
3204.0
4216.0
59.9
108.4
191.0
276.7
347.5
426.4
503.9
659.1
973.4
1453.3
1912.3
0.47
0.66
0.85
0.99
1.10
1.22
1.32
1.50
1.84
2.25
2.56
11.9
16.7
21.5
25.3
28.0
31.0
33.5
38.0
46.8
57.1
65.1
—
8.8
262
0.772
1.0
4.0
8.0
10.0
16.0
2.2
2.6
5.6
8.5
9.7
13.1
43.0
41.0
32.0
28.0
26.0
23.0
Jacket sequentially market at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 3
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: Riser Multipair
Pair No.
Tip
Ring
1
White
Blue
Binder group
2
White
Orange
White/Orange
3
White
Green
White/Green
4
White
Brown
White/Brown
5
White
Slate
White/Slate
6
Red
Blue
Red/Blue
7
Red
Orange
Red/Orange
8
Red
Green
Red/Green
Red/Brown
White/Blue
9
Red
Brown
10
Red
Slate
Red/Slate
11
Black
Blue
Black/Blue
12
Black
Orange
Black/Orange
13
Black
Green
Black/Green
14
Black
Brown
Black/Brown
15
Black
Slate
Black/Slate
16
Yellow
Blue
Yellow/Blue
17
Yellow
Orange
Yellow/Orange
18
Yellow
Green
Yellow/Green
19
Yellow
Brown
Yellow/Brown
20
Yellow
Slate
Yellow/Slate
21
Violet
Blue
Violet/Blue
22
Violet
Orange
Violet/Orange
23
Violet
Green
Violet/Green
24
Violet
Brown
Violet/Brown
25
Violet
Slate
Violet/Slate
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.67
DataTwist 5e ScTP Cable
®
TIA/EIA-568-B.2, Category 5e Nonbonded-Pair Cables
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Description
Standard
Unit Wt.
Lbs.
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
kg
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Overall Beldfoil Shield • Drain Wire* • RJ-45 Compatible • See Color Code Chart (below)
®
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Gray or Black)
1533R
NEC:
CMR
CEC:
CMR
4
1000
304.8
A-1000 A-304.8
†
500.0
1640
34.0
37.0
57.4
15.5
16.8
26.1
.260 6.60
9.38
3.0
330
†1640 ft. put-up available in Gray only.
Shield is bonded to jacket inner wall for electrical stability.
Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-B.2, Category 5e
1
4
8
10
16
20
25
31.25
62.5
100
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
60
49
43
41
36
34
31
28
18
10
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
Drain Wire
1300SB
u
NEC:
CMG-LS
CEC:
CMG-LS FT4
Limited
Smoke
4
1000
304.8
35.0
15.9
.260 6.60
9.3
3.0
330
1
4
8
10
16
20
25
31.25
62.5
100
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
60
49
43
41
36
34
31
28
18
10
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
LSZH and ABS Type Approved
Jacket sequentially marked at 2 ft. intervals.
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Available in Red, Orange, Yellow, Green, Blue, Gray, Black or Natural)
1533P
NEC:
CMP
CEC:
CMP
4
Shield is bonded to jacket inner wall for electrical stability.
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-B.2, Category 5e
1000
A-1000
304.8
A-304.8
35.0
38.0
15.9
17.2
.235 6.00
9.38
3.0
330
1
4
8
10
16
20
25
31.25
62.5
100
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
60
49
43
41
36
34
31
28
18
10
60.8
48.7
42.7
40.8
36.7
34.7
32.8
30.9
24.8
20.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
20.0
23.0
24.5
25.0
25.0
25.0
24.3
23.6
21.5
20.1
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss
ScTP = Screened (Overall Foil) Twisted Pair(s)
*Drain wire is 24 AWG stranded tinned copper.
Color Codes: DataTwist 5e ScTP
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Polypropylene Insulation (Color Code: See Chart Below) • Black Low-Smoke, Zero-Halogen Jacket
300V RMS
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.68
DataTwist 5 ScTP Cable
®
TIA/EIA-568-A, Category 5 Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max.
DCR
Inch mm
(Ω/
100m)
Max.
DCR
Unbal.
(%)
Max.
Cap.
Unbal.
(pF/
100m)
Freq.
Max.
Atten.
(MHz)
(dB/
100m)
Min.
PSUM
NEXT
(dB)
Input
Imped.
(Ω)
Min.
SRL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Overall Beldfoil® Shield • Drain Wire* • RJ-45 Compatible • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple or Light Gray)
1624R
NEC:
CMR
CEC:
CMR
4
1000
304.8
A-1000 A-304.8
†
500.0
1640
33.0
36.0
54.1
15.0
16.3
24.7
.260 6.60
9.38
3.0
300
†1640 ft. put-up available in Gray only.
Shield is bonded to jacket inner wall for electrical stability.
Jacket sequentially marked at 2 ft. intervals. • Third party verified to TIA/EIA-568-A, Category 5
1
4
8
10
16
20
25
31.25
65.5
100
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
23.0
23.0
23.0
23.0
23.0
23.0
22.0
21.1
18.0
16.0
Plenum • FEP Teflon® Insulation • Flamarrest® Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Gray or Natural)
1624P
NEC:
CMP
CEC:
CMP
4
1000
304.8
A-1000 †† A-304.8
32.0
35.0
14.5
15.9
.230 5.84
9.38
3.0
††A-1000
ft. put-up available in Yellow, Blue, Gray or Natural only.
Shield is bonded to jacket inner wall for electrical stability.
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-A, Category 5
300
1
4
8
10
16
20
25
31.25
65.5
100
2.0
4.1
5.8
6.5
8.2
9.3
10.4
11.7
17.0
22.0
62.3
53.3
48.8
47.3
44.3
42.8
41.3
39.9
35.4
32.3
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±15
23.0
23.0
23.0
23.0
23.0
23.0
22.0
21.1
18.0
16.0
DCR = DC Resistance • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • ScTP = Screened (Overall Foil) Twisted Pair(s)
*Drain wire is 24 AWG stranded tinned copper on 1624R and 24 AWG solid tinned copper on 1624P.
Color Codes: DataTwist 5 ScTP
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.69
DataTwist 5 ScTP Cable
®
TIA/EIA-568-TSB 36, Category 5 Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No.
C(UL) CEC
of
Type
Pairs
Standard Lengths
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Inch
mm
Max.
DCR
(Ω/
100m)
Max. Max.
Max.
Cap. Freq. Atten. Min.
DCR
NEXT
Unbal.
Unbal.
(dB/
(MHz)
(pF/
(dB)
100m)
(%)
100m)
Input
Imped.
(Ω)
Min.
RL
(dB)
24 AWG Solid Bare Copper Conductors • Twisted Pairs • Overall Beldfoil® Shield • Drain Wire • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Gray or Blue)
1633A
NEC:
CM
CEC:
CM
4
U-1000
1000
U-304.8
304.8
30.0
32.0
13.6
14.5
.260
6.60
9.38
5.0
330
4
10
16
31.25
62.5
100
4.1
6.5
8.2
11.7
17.0
22.0
53.0
47.0
44.0
40.0
35.0
32.0
100±15
100±15
100±15
100±15
100±15
100±15
N/A
N/A
N/A
N/A
N/A
N/A
5.0
330
4
10
16
31.25
62.5
100
4.1
6.5
8.2
11.7
17.0
22.0
53.0
47.0
44.0
40.0
35.0
32.0
100±15
100±15
100±15
100±15
100±15
100±15
N/A
N/A
N/A
N/A
N/A
N/A
Rip Cord
Not compatible with RJ-11/12/45 connectors.
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-TSB 36, Category 5
1668A
NEC:
CM
CEC:
CM
2x4
1000
1640
304.8
500.0
70.0
109.9
31.8
49.9
.518
x
.254
13.16
x
6.45
9.38
Rip Cord
Not compatible with RJ-11/12/45 connectors.
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-TSB 36, Category 5 (Leg 1 & 2). A polarity rib is applied to one leg.
DCR = DC Resistance • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • ScTP = Screened (Overall Foil) Twisted Pair(s)
Color Codes: DataTwist 5 ScTP
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Non-Plenum • Dual • Polyolefin Insulation • Gray PVC Jacket with Polarity Rib
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.70
VideoTwist 6 UTP Cable for RGB Video
®
TIA/EIA-568-B.2-1, Category 6 Bonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
23 AWG Bonded-Pairs Solid BC Conductors • Twisted Pairs • Rip Cord • See Color Code Chart (below)
Non-Plenum • Polypropylene Insulation • PVC Jacket
7989R
NEC:
CMR
CEC:
CMG
4
1000
1640
304.8
500.0
32.0
52.5
14.5
23.8
.365 9.27
x
x
.165 4.12
9.0
3.0
49.2
1
4
10
16
31.25
62.5
100
200
250
2.0
3.8
6.0
7.6
10.7
15.4
19.8
29.0
32.8
72.3
63.3
57.3
54.3
49.9
45.4
42.3
37.8
36.3
70.3
59.5
51.3
46.7
39.2
30.0
22.5
8.8
3.5
64.8
52.7
44.8
40.7
34.9
28.8
24.8
18.7
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
20.0
23.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
17.2
28.3
.365 9.27
x
x
.165 .4.12
9.0
3.0
49.2
1
4
10
16
31.25
62.5
100
200
250
2.0
3.8
6.0
7.6
10.7
15.4
19.8
29.0
32.8
72.3
63.3
57.3
54.3
49.9
45.4
42.3
37.8
36.3
70.3
59.5
51.3
46.7
39.2
30.0
22.5
8.8
3.5
64.8
52.7
44.8
40.7
34.9
28.8
24.8
18.7
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
20.0
23.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 6
Plenum • FEP Insulation • Flamarrest® Jacket
7989P
NEC:
CMP
CEC:
CMP
4
1000
1640
304.8
500.0
38.0
62.3
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2-1, Category 6
ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss •
UTP = Unshielded Twisted Pair(s)
Color Codes: VideoTwist 6 RGB
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.71
DataTwist 5e UTP Cable for RGB Video
®
TIA/EIA-568-B.2, Category 5e Bonded and Nonbonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
Low Skew 24 AWG Bonded Pairs Solid BC Conductors • Twisted Pairs • Skew 9,0ns/100m nom. • Rip Cord • See Color Code Chart
Non-Plenum • Polyolefin Insulation • Green PVC Jacket
7988R
NEC:
CMR
CEC:
CMG
4
U-1000
U-1640
U-304.8
U-500.0
22.0
36.1
10.0
16.4
.204 5.18
9.0
3.0
66.0
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.4
65.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40.8
36.0
28.2
18.4
10.3
1.0
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
10.4
17.1
.193 4.90
9.0
3.0
66.0
1
4
10
16
31.25
62.5
100
200
2.0
4.1
6.5
8.2
11.7
17.0
22.0
32.4
65.3
53.3
47.3
44.3
39.9
35.4
32.3
27.8
60.3
49.2
40.8
36.0
28.2
18.4
10.3
1.0
60.8
48.7
40.8
36.7
30.9
24.8
20.8
14.7
100±15
100±15
100±15
100±15
100±15
100±15
100±15
100±25
20.0
23.0
25.0
25.0
23.6
21.5
20.1
15.0
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
7988P
NEC:
CMP
CEC:
CMP
4
U-1000
U-1640
U-304.8
U-500.0
23.0
37.7
Rip Cord
Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e
ACR = Attenuation Crosstalk Ratio • BC = Bare Copper • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss •
UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 5e RGB
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • FEP Insulation • Green Flamarrest® Jacket
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.72
MediaTwist and DataTwist 6 UTP Patch Cables
®
®
TIA/EIA-568-B.2-1, Category 6
Enhanced Category 6 Bonded-Pair Cables
Description
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Part
No.
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
Patch Cables • 24 AWG Bonded-Pairs Stranded (7x32) Tinned Copper Conductor • RJ-45 Compatible • See Color Code Chart (below)▲
Non-Plenum • Polyolefin Insulation • PVC Jacket (Yellow, Green, Blue, Purple, Light Gray, Gray, White or Black)
1875GB
NEC:
CMR
CEC:
CMR
4
1000 †
304.8
A-1000 †† A-304.8
31.0
32.0
14.1
14.5
.365 9.27
x
x
.165 4.19
9.0
3.0
49.2
Rip Cord
†1000 ft. put-up not available in Purple.
††A-1000 ft. put-up not available in Black.
U.S. Patents 5,606,151; 5,734,126; 5,763,823 and 5,821,467
Third party verified to TIA/EIA-568-B.2-1, Category 6 Patch
1
4
8
10
16
25
31.25
62.5
100
155
200
250
300
350
400
500
1.9
3.7
5.3
5.9
7.5
9.5
10.6
15.4
19.8
25.1
29.0
32.8
35.2
39.8
43.0
49.0
72.3
63.3
58.8
57.3
54.3
51.4
49.9
45.4
42.3
39.5
37.8
36.3
35.2
34.2
—
—
70
59
53
51
46
42
39
30
25
14
10
3
>0
—
—
—
64.8
52.8
46.7
44.8
40.7
36.8
34.9
28.9
24.8
20.9
18.8
16.8
15.2
13.9
—
—
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±15
100±15
100±20
100±20
100±22
100±32
100±32
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
21.0
21.0
21.0
18.0
18.0
17.0
14.0
14.0
Patch Cables • 24 AWG Solid BC Conductors • Twisted Pairs • Central Slit-Film Filler • RJ-45 Compatible* • See Color Code Chart (below)▲
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Gray, White or Black)
7883A
NEC:
CM
CEC:
CM
4
1000
304.8
24.0
10.9
.205 5.21
9.38
Rip Cord
5.0
330
1
10
20
31.25
62.5
100
200
250
2.4
7.1
10.2
12.8
18.5
23.8
34.8
39.4
72.3
57.3
52.8
49.9
45.4
42.3
37.8
36.3
69.9
50.2
42.6
37.1
26.9
18.5
3.0
—
64.8
44.8
38.8
34.9
28.9
24.8
18.8
16.8
100±15
100±15
100±15
100±15
100±15
100±15
100±22
100±32
20.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
Jacket sequentially marked at 2 ft. intervals.
Third party verified to TIA/EIA-568-B.2-1, Category 6 Patch
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: MediaTwist Patch
(1875GB)
Pair No.
▲
Color Combination
Color Codes: DataTwist 6 Patch
(7883A)
Pair No.
Color Combination
1
White/Brown Stripe & Brown
1
White/Blue Stripe & Blue
2
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
3
White/Green Stripe & Green
4
White/Orange Stripe & Orange
4
White/Brown Stripe & Brown
Color rotation available for T568-A or T568-B wiring schemes.
Handy Cable
Preparation Tool
for Bonded-Pairs
See page 15.40
for details.
▲
Color rotation available for T568-A or T568-B wiring schemes.
(Part No. 1797B)
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.73
DataTwist 350 UTP Patch Cable
®
TIA/EIA-568-B.2, Category 5e
Enhanced Category 5e Bonded-Pair Cables
Description
Part
No.
UL NEC/
No. Standard Lengths
C(UL) CEC of
Type
Pairs
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Max. Max.
DCR DCR
(Ω/ Unbal.
Inch mm 100m) (%)
Max.
Max. Min. Min. Min.
Cap. Freq. Atten. PSUM PSUM PSUM Input Min.
ACR ELFEXT Imped. RL
Unbal.
(MHz) (dB/ NEXT (dB/
(pF/
(dB/
(Ω)
(dB)
100m) (dB)
100m)
100m)
100m)
24 AWG Bonded-Pairs Stranded (7x32) Tinned Copper Conductors • RJ-45 Compatible • See Color Code Chart (below)
Non-Plenum • Polyolefin Insulation • PVC Jacket (Available in Red, Orange, Yellow, Green, Blue, Purple, Black or Gray)
1752A
NEC:
CM
CEC:
CM
4
U-1000
1000
Jacket sequentially marked at 2 ft. intervals.
U.S. Patents 5,606,151; 5,734,126 and 5,763,823
Third party verified to TIA/EIA-568-B.2, Category 5e Patch
U-304.8
304.8
24.0
26.0
10.9
11.8
.220 5.59
9.0
3.0
66.0
1
4
8
10
16
25
31.25
62.5
100
155
200
250
350
2.4
4.8
6.8
7.7
9.7
12.4
13.9
20.2
26.0
33.2
38.4
43.7
53.2
65.3
56.3
51.8
50.3
47.3
44.3
42.9
38.4
35.3
32.5
30.8
29.3
27.2
62.9
51.5
45.0
42.6
37.5
31.9
29.0
18.3
9.2
—
—
—
—
60.8
48.7
42.7
40.8
36.7
32.8
30.9
24.9
20.8
16.9
14.7
12.8
9.9
100±12
100±12
100±12
100±12
100±12
100±15
100±15
100±15
100±15
100±18
100±20
100±20
100±22
20.0
23.0
24.5
25.0
25.0
24.3
23.6
21.5
20.1
19.0
19.0
18.0
17.0
15 • Networking — Copper
ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s)
Color Codes: DataTwist 350 Patch
Pair No.
Color Combination
1
White/Blue Stripe & Blue
2
White/Orange Stripe & Orange
3
White/Green Stripe & Green
4
White/Brown Stripe & Brown
Get the Bonded-Pairs
Cable Preparation Tool
See page 15.40 for details.
(Part No. 1797B)
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.74
IEEE 802.3 • ISO/IEC 8802.3 10Base2 and 10Base5
Trunk Cables — Thinnet and Thicknet
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Imp. Vel.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100
Ft. 100m
Thinnet 10Base2 • 20 AWG Stranded (19x32) .037″ Tinned Copper Conductors • Duobond ® II + Tinned Copper Braid Shield (93% Coverage)
Non-Plenum • Ethernet • Foam HDPE Insulation • Gray PVC Jacket
UL AWM
Style 1354
(30V 60°C)
9907
NEC:
CL2, CM
CEC:
CM
500
152.4
U-1000 U-304.8
1000
304.8
1640
500.0
2500
762.0
3280 1000.0
12.5
25.0
25.0
41.0
62.5
82.0
5.7
11.4
11.4
18.6
28.4
37.3
20 AWG
(19x32)
.037″
Tinned
Copper
8.8Ω/M′
28.9Ω/km
.102
2.59 Duobond II .185 4.70
50
80% 25.4 83.3
+ 93%
Tinned
Copper
For Plenum versions of 9907,
Braid
see 89907 or 82907.
5.8Ω/M′
19.0Ω/km
DEC Part No. 17-01248-00
1
.43
10 1.30
50 2.90
100 4.20
200 6.10
400 8.90
700 12.10
900 13.90
1000 14.80
1.4
4.3
9.5
13.8
20.0
29.2
39.7
45.6
48.6
Plenum Ethernet • Foam FEP Insulation • Natural Flamarrest® Jacket
300V 75°C
82907
NEC:
CL2P,
CMP
CEC:
CMP
500† 152.4
U-1000 U-304.8
1000† 304.8
2500† 762.0
12.5
23.0
24.0
57.5
5.7
10.5
10.9
26.1
20 AWG
(19x32)
.037″
Tinned
Copper
8.8Ω/M′
28.9Ω/km′
.095
2.41 Duobond II .160
+ 93%
Tinned
Copper
Braid
5.8Ω/M′
19.0Ω/km
4.06
50
80%
25.4
83.3
1
.43
10 1.30
50 2.90
100 4.20
200 6.10
400 9.20
700 12.90
900 15.00
1000 16.00
1.4
4.3
9.5
13.8
20.0
30.2
42.3
49.2
52.5
4.06
50
80%
25.4
83.3
1
.43
10 1.30
50 2.90
100 4.20
200 6.10
400 9.20
700 12.90
900 15.00
1000 16.00
1.4
4.3
9.5
13.8
20.0
30.2
42.3
49.2
52.5
85.0
1
5
10
50
100
200
400
700
900
1000
.19 ▲ .62
.37 ▲ 1.21
.52 ▲ 1.71
1.20 ▲ 3.94
1.70 ▲ 5.58
2.55 ▲ 8.37
3.90 ▲ 12.80
5.50 ▲ 18.10
6.50 ▲ 21.30
6.90 ▲ 22.60
85.0
1
5
10
50
100
200
400
700
900
1000
.18
.59
.37 ▲ 1.21
▲
.52 1.71
1.15 3.77
1.65 5.41
2.45 8.04
3.80 12.50
5.60 18.40
6.80 22.30
7.20 23.60
Plenum Ethernet • Foam FEP Insulation • Gray Fluorocopolymer Jacket
300V 150°C
89907†
NEC:
CL2P,
CMP
CEC:
CMP
500†
1000†
2500†
152.4
304.8
762.0
12.5
24.0
60.0
5.7
10.9
27.3
DEC Part No. 17-01246-00
Suitable for Outdoor and Direct Burial applications.
20 AWG
(19x32)
.037″
Tinned
Copper
8.8Ω/M′
28.9Ω/km
.095
2.41 Duobond II .160
+ 93%
Tinned
Copper
Braid
5.8Ω/M′
19.0Ω/km
Thicknet 10Base5 • 12 AWG Solid .086″ Bare Copper Conductor • Duobond IV* Quad Shield (100% Coverage)
Non-Plenum • Ethernet • Foam Polyethylene Insulation • Yellow PVC Jacket
UL AWM
Style 1478
(30V 60°C)
9880
NEC:
CL2, CM
CEC:
CM
500
1000
1640
152.4 66.0 30.0
304.8 131.0 59.5
500.0 219.8 99.9
12 AWG
.243
(solid)
.086″
Bare Copper
1.42Ω/M′
4.66Ω/km
DEC Part No. 17-00451-00
Ring-band stripes marked every 2.5 meters to aid users in tap placement.
6.17 Duobond IV .405 10.29 50
78% 26.0
(Duobond II
+ 94%
TC Braid
For Plenum version of 9880,
+ Duofoil®
see 89880.
+ 90%
TC Braid)
1.52Ω/M′
5.0Ω/km
Plenum Ethernet • Foam FEP Insulation • Orange Fluorocopolymer Jacket
150°C
89880
NEC:
CL2P,
CMP
CEC:
CMP
1000†
1640†
304.8 134.0 60.9
500.0 224.7 102.1
DEC Part No. 17-00324-00
Suitable for Outdoor and Direct Burial applications.
Ring-band stripes marked every 2.5 meters to aid users in tap placement.
12 AWG
.245
(solid)
.086″
Bare Copper
1.42Ω/M′
4.66Ω/km
6.22 Duobond IV .375
(Duobond II
+ 94%
TC Braid
+ Duofoil
+ 90%
TC Braid)
1.52Ω/M′
5.0Ω/km
9.53
50
78%
26.0
DCR = DC Resistance • HDPE = High-density Polyethylene • TC = Tinned Copper
*Duobond IV = Duobond II (100% coverage) + tinned copper braid (90% coverage) + Duofoil ® (100% coverage) + tinned copper braid (90% coverage).
Plenum version is Duobond II (100% coverage) + tinned copper braid (94% coverage) + Duofoil (100% coverage) + tinned copper braid (90% coverage).
† Spools are one piece, but length may vary ±10% from length shown.
▲Maximum Attenuation
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.75
IEEE 802.3 • ISO/IEC 8802.3 10Base5
Transceiver Cables
UL NEC/
No.
Part
No. C(UL) CEC of
Type
Pairs
Description
Color
Code
Standard Lengths
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Conductor Shielding Nominal
OD
(stranding) Materials
Nom. DCR Nom. DCR Inch mm
Drain
Wire
Nominal Capacitance
Nom. Nom.
Imp. Vel.
of
*
*
**
**
(Ω) Prop. pF/Ft. pF/m
pF/Ft. pF/m
28 and 24 AWG Stranded TC Conductors • Twisted Pairs • Overall Polyester Isolation Tape + Duofoil® + TC Braid Shield (92% Coverage) • Drain Wire
Non-Plenum • Polypropylene Insulation • Light Gray PVC Jacket
9903
NEC:
CMG
CEC:
CMG
4
Gray/White,
Yellow/Orange,
Blue/Green,
Black/Red
500
1000
152.4
304.8
21.5 9.8
43.0 19.5
3 Pair:
28 AWG
(7x36)
TC
65.0Ω/M′
213.0Ω/km
1 Pair:
24 AWG
(7x32)
TC
24.0Ω/M′
78.7Ω/km
Each Pair
Individually
Beldfoil®
Shielded
Duofoil®
Polyester Tape
Z-Fold®
◆
3 Pairs
Polyester
Isolation
Tape
+ Duofoil
+ 92%
Tinned
Copper
Braid
2.9Ω/M′
9.5Ω/km
.250 6.35
24
78 ◆
AWG
Stranded
Tinned
Copper
66%
19.7
64.6
34.8
114.2
20 AWG Stranded (7x28) TC Conductors • Twisted Pairs • Overall Polyester Isolation Tape + Duofoil + TC Braid Shield (95% Coverage) • Drain Wire
Non-Plenum • Datalene® Insulation • Light Gray PVC Jacket
UL AWM
Style 2919
(30V 80°C)
9901
NEC:
CL2, CM
CEC:
CM
4
Gray/White,
Yellow/Orange,
Blue/Green,
Black/Red
500
1000
152.4 53.5 24.3
304.8 106.0 48.2
Duofoil
Beldfoil®
20 AWG
(7x28)
Tinned
Copper
Each Pair
Individually
Beldfoil
Shielded
10.5Ω/M′
34.4Ω/km
Polyester
Isolation
Tape
+ Duofoil
+ 95%
Tinned
Copper
Braid
2.0Ω/M′
6.6Ω/km
.415 10.54
20 AWG
Polyester
(7x28)
Isolation
Tinned
Tape
Copper
+ Duofoil
Each Pair
+ 95%
Individually
Tinned
Beldfoil
Copper
Shielded
Braid
10.5Ω/M′ 1.65Ω/M′
34.4Ω/km 5.4Ω/km
.495 12.58
22
78
AWG
Stranded
Tinned
Copper
78%
16.7
54.8
29.5
96.8
For Plenum version of 9901,
see 89901.
DEC Part No. 17-01320-00
UL AWM
Style 2919
(30V 80°C)
9902
Polyester
Tape
NEC:
CL2, CM
CEC:
CM
5
Gray/White,
Yellow/Orange,
Blue/Green,
Red/Brown,
Red/Black
500
1000
152.4 76.0 34.5
304.8 145.0 65.9
Duofoil
20
78
AWG
Stranded
Tinned
Copper
78%
16.7
54.8
29.5
96.8
22
78
AWG
Stranded
Tinned
Copper
78%
16.7
54.8
29.5
96.8
Beldfoil
Plenum • FEP Teflon® Insulation†† • Light Gray Fluorocopolymer (PVDF) Jacket
150°C
89901
NEC:
CMP
CEC:
CMP
4
Gray/White,
Yellow/Orange,
Blue/Green,
Red/Black
500†† 152.4 51.5 23.4
1000†† 304.8 104.0 47.3
Z-Fold®
Duofoil
20 AWG
(7x28)
Tinned
Copper
Each Pair
Individually
Beldfoil
Shielded
10.5Ω/M′
34.4Ω/km
Polyester
Isolation
Tape
+ Duofoil
+ 95%
Tinned
Copper
Braid
1.5Ω/M′
4.9Ω/km
.370 9.40
Polyester Tape
Beldfoil
††Foam
FEP (data pairs) and solid FEP (power pair).
DEC Part No. 17-01319-00 • Suitable for Outdoor and Direct Burial applications.
DCR = DC Resistance • TC = Tinned Copper
* Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
†† Spools are one piece, but length may vary ±10% from length shown.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
UL AWM
Style 2919
(30V 80°C)
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.76
IEEE 802.3 • Ethernet 10Base5
Transceiver Cables
UL NEC/
No.
Part
No. C(UL) CEC of
Type
Pairs
Description
Color
Code
Standard Lengths
Ft.
m
Standard
Unit Wt.
Lbs.
Conductor Shielding Nominal
OD
(stranding) Materials
Nom. DCR Nom. DCR Inch mm
kg
Drain
Wire
Nominal Capacitance
Nom. Nom.
Imp. Vel.
of
*
*
**
**
(Ω) Prop. pF/Ft. pF/m
pF/Ft. pF/m
20 AWG Stranded (7x28) .038″ TC Cond. • Twisted Pairs • Beldfoil® (100% Coverage) + Polyester Tape + TC Braid Shield (95% Cov,) • Drain Wire
Non-Plenum • Ethernet • Datalene® Insulation • Light Blue PVC Jacket
UL AWM
Style 2919
(30V 80°C)
9892
NEC:
CM, CL2
CEC:
CM
4
Gray/White,
Yellow/Orange,
Blue/Green,
Black/Red
500
1000
152.4 51.5 23.4
304.8 101.0 45.9
Drain Wire
20 AWG
(7x28)
.038″
Tinned
Copper
9.5Ω/M′
31.2Ω/km
Polyester
Isolation
Tape
+ 95%
Tinned
Copper
Braid
1.9Ω/M′
6.2Ω/km
.398 10.1
22
AWG
(7x30)
Tinned
Copper
78
78%
16.7
54.8
29.5
96.8
Polyester Tape
20 AWG Stranded (7x28) .038″ TC Conductors • Twisted Pairs • Beldfoil® Inner + Overall Duofoil® (100% Coverage) + TC Braid Shield (95% Cov.)
Plenum • Ethernet • Foam FEP Insulation (Data) • Solid FEP Insulation (Power) • Brown Fluorocopolymer Jacket
89892
Drain Wire
NEC:
CMP
CEC:
CMP
4
Gray/White,
Yellow/Orange,
Blue/Green,
Red/Black
500
1000
152.4 50.0 22.7
304.8 101.0 45.9
Duofoil®
20 AWG
(7x28)
.038″
Tinned
Copper
9.5Ω/M′
31.2Ω/km
Polyester
Isolation
Tape
+ Duofoil
+ 95%
Tinned
Copper
Braid
1.5Ω/M′
4.9Ω/km
.359
9.1
22
AWG
(7x30)
Tinned
Copper
78
78%
16.7
54.8
29.5
96.8
Polyester Tape
Z-Fold®
20 and 22 AWG Stranded TC Conductors • Twisted Pairs • Beldfoil® Inner Shield (100% Coverage) + Overall TC Braid Shield (95% Coverage)
Non-Plenum • Ethernet • Foam HDPE (22 AWG) and PVC (20 AWG) Insulation • Light Blue PVC Jacket
UL AWM
Style 2919
(30V 80°C)
9891
NEC:
CM
CEC:
CM
4
Black/White,
Yellow/Orange,
Blue/Green,
Gray/Purple
100
500
1000
30.4
152.4
304.8
Drain Wire
Duofoil®
Polyester Tape
Z-Fold®
◆
3 Pairs
7.4 3.7
36.0 16.3
70.0 16.3
3 Pair:
Each Pair .316
22 AWG Individually
(7x30)
Beldfoil®
TC
Shielded,
14.7Ω/M′
Overall
48.23Ω/km Duofoil
Foam HDPE + 95%
Insulation
Tinned
1 Pair:
Copper
20 AWG
Braid
(7x28)
1.8Ω/M′
TC
5.9Ω/km
9.5Ω/M′
31.1Ω/km
PVC Insulation
8.0
22
78 ◆ 78%◆ 16.7◆ 54.8◆ 29.5◆ 96.8◆
AWG
(7x30)
Tinned
Copper
DCR = DC Resistance • HDPE = High=density Polyethylene • TC = Tinned Copper
* Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.77
IEEE 802.4 MAP & Mini-MAP • IEEE 802.7
Broadband Coaxial Cables
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Imp. Vel.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100
Ft. 100m
RG-6/U Type • 18 AWG Solid Bare Copper-covered Steel Conductor • Duobond® IV* Quad Shield (100% Coverage)
Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket
3131A
NEC:
CL2R,
CMR
CEC:
CMG
1000 ** 304.8 41.0
2500 † 762.2 102.5
18.6
46.5
18 AWG
(solid)
.040″
BCCS
28.0Ω/M′
91.8Ω/km
.180
4.57 Duobond IV .300
Quad Shield
3.6Ω/M′
11.8Ω/km
7.62
75
82%
16.2
53.1
Sweep tested 5 MHz to 400 MHz.
CPE jacket optional.
Tap marks every 2.6 meters to aid users in installation.
1
2
5
10
20
50
100
200
300
400
.35
.38
.45
.59
.86
1.37
1.97
2.82
3.48
4.04
1.2
1.3
1.5
1.9
2.8
4.5
6.5
9.3
11.4
13.3
1
2
5
10
20
50
100
200
300
400
.36
.38
.50
.65
.95
1.50
2.12
2.99
3.66
4.23
1.2
1.3
1.6
2.1
3.1
4.9
7.0
9.8
12.0
13.9
3132A
NEC:
CMP
CEC:
CMP
1000 ** 304.8
36.0
16.4
18 AWG
(solid)
.040″
BCCS
28.0Ω/M′
91.8Ω/km
.170
4.32 Duobond IV .274
Quad Shield
3.6Ω/M′
11.8Ω/km
6.96
75
82%
16.3
53.5
Sweep tested 5 MHz to 400 MHz.
Tap marks every 2.6 meters to aid users in installation.
Suitable for Outdoor and Direct Burial applications.
BCCS = Bare Copper Covered Steel • DCR = DC Resistance
*Duobond IV Quad Shield = Duobond + 60% aluminum braid + Duofoil® + 40% aluminum braid.
†Spools are one piece, but length may vary ±10% from length shown.
**1000' exact 1 pc.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.78
IEEE 802.4 MAP & Mini-MAP • IEEE 802.7
Broadband Coaxial Cables
Description
Part
No.
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Imp. Vel.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100
Ft. 100m
RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV* Quad Shield (100% Coverage)
Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket
3094A
NEC:
CL2R,
CMR
CEC:
CMG
500 ** 152.4 31.0
1000 ** 304.8 62.0
2000 † 609.6 122.0
14.1
28.2
55.3
14 AWG
(solid)
.064″
BCCS
11.0Ω/M′
36.1Ω/km
.280
7.11 Duobond IV .407
Quad Shield
1.5Ω/M′
4.9Ω/km
10.34
75
82%
16.2
53.1
Sweep tested 5 MHz to 400 MHz.
CPE jacket optional.
Tap marks every 2.6 meters to aid users in installation.
1
2
5
10
20
50
100
200
300
400
.16
.18
.26
.38
.55
.83
1.17
1.60
1.99
2.30
.5
.6
.9
1.2
1.8
2.7
3.8
5.3
6.6
7.6
1
2
5
10
20
50
100
200
300
400
.17
.22
.28
.40
.60
1.20
1.70
2.50
3.04
3.50
.6
.7
.9
1.3
2.0
3.9
5.6
8.2
10.0
11.5
Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket
150°C
3095A
NEC:
CMP
CEC:
CMP
1000 ** 304.8
76.0
34.5
14 AWG
(solid)
.064″
BCCS
11.0Ω/M′
36.1Ω/km
.280
7.11 Duobond IV .387
Quad Shield
3.9Ω/M′
12.8Ω/km
9.83
75
82%
16.5
54.1
Sweep tested 5 MHz to 400 MHz.
Tap marks every 2.6 meters to aid users in installation.
Suitable for Outdoor and Direct Burial applications.
BCCS = Bare Copper Covered Steel • DCR = DC Resistance
*Duobond IV Quad Shield = Duobond + 60% aluminum braid + Duofoil® + 40% aluminum braid.
†Spools are one piece, but length may vary ±10% from length shown.
**500' & 1000' exact 1 pc.
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.79
IEEE 802.5; ISO/IEC 8802.5
IBM Cabling System
Types 1A and 1
Description
Standard
UL NEC/
No. Standard Lengths
Unit Wt.
Part
C(UL) CEC
of
No.
Type
Pairs
Ft.
m
Lbs.
kg
Nominal
OD
AWG
(stranding)
Shielding
Diameter
Inch mm Nom. DCR
Nominal
Maximum
Nom. Capacitance
Freq. Attenuation
Imped.
(MHz) (dB/
(dB/
*
*
(Ω) pF/Ft.
pF/m
1000′) 100m)
Min.
NEXT
(dB/
(dB/
3280′) 1000m)
IBM Type 1A • 22 AWG Solid BC Conductors • Each Pair Individually Beldfoil® Shielded + Overall TC Braid Shield (65% Coverage) • Rip Cord
Non-Plenum • Flame-retardant Foam Polyethylene Insulation • Black PVC Jacket
IBM Part No.
4716748
33G2772
9688
NEC:
CMG
CEC:
CMG
2
500†
1000†
2000†
3600†
152.4
304.8
609.8
1097.6
26.5
50.0
102.0
190.8
12.0 .296 7.52
x
x
22.7
46.3 .431 10.95
86.5
22
(solid)
BC
.026″
16.7Ω/M′
54.7Ω/km
100%
Beldfoil
Each Pair
+ 65%
TC Braid
Overall
150
8.5
27.9
4
6.7
16
13.4
100
37.5
300
65.2
100†† 40.8
300†† 71.0
600†† 100.3
2.2
4.4
12.3
21.4
13.4
23.3
32.9
58.0
50.4
38.5
31.3
—
—
—
58.0
50.4
38.5
31.3
—
—
—
150
8.5
27.9
4
6.7
16
13.4
100
37.5
300
65.2
100†† 40.8
††
300
71.0
600†† 100.3
2.2
4.4
12.3
21.4
13.4
23.3
32.9
58.0
50.4
38.5
31.3
—
—
—
58.0
50.4
38.5
31.3
—
—
—
Rip Cord
Meets IEEE 802.5 and TIA/EIA-568-A specifications, ETL verified. For Token Ring (4/16 Mbps), FDDI over copper, and video applications.
IBM qualified Type 1A Media cable for use in IBM Cabling Systems. For Non-suffix “A” Type IBM Product, see 1634A below.
82688
NEC:
CMP
CEC:
CMP
2
1000†
304.8
47.0
21.4 .248 6.30
x
x
.348 8.84
22
(solid)
BC
.026″
16.7Ω/M′
54.7Ω/km
100%
Beldfoil
Each Pair
+ 65%
TC Braid
Overall
Rip Cord
Meets IEEE 802.5 and TIA/EIA-568-A specifications, ETL verified.
IBM qualified Type 1A Media cable for use in IBM Cabling Systems. For Token Ring (4/16 Mbps), FDDI over copper, and video applications.
IBM Type 1 • 22 AWG Solid BC Conductors • Each Pair Individually Beldfoil Shielded + Overall TC Braid Shield (65% Coverage) • Rip Cord
Non-Plenum • Flame-retardant Foam Polyethylene Insulation • Black PVC Jacket
IBM Part No.
4716748
1634A
NEC:
CMG
CEC:
CMG
2
1000†
2000†
3600†
304.8
609.8
1097.6
50.0
102.0
190.8
22.7 .296 7.52
x
x
46.4
86.7 .431 10.95
22
(solid)
BC
.026″
17.4Ω/M′
57.1Ω/km
100%
Beldfoil
Each Pair
+ 65%
TC Braid
Overall
150
8.5
27.9
4
16
6.7
13.4
2.2
4.4
58.0
40.0
58.0
40.0
Rip Cord
Meets IEEE 802.5 and TIA/EIA-568-A specifications, ETL verified. For Token Ring (4/16 Mbps), FDDI over copper, and video applications.
IBM qualified Type 1 Media cable for use in IBM Cabling Systems. For Suffix A counterpart see 9688 above.
DCR = DC Resistance • BC = Bare Copper • NEXT = Near-end Crosstalk • TC = Tinned Copper
* Capacitance between conductors
but length may vary ±10% from length shown.
† Spools are one piece,
†† Common mode
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
Plenum • Foam FEP Teflon® Insulation • Black Flamarrest® Jacket
IBM Part No.
4716749
33G8220
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.80
IEEE 802.5; ISO/IEC 8802.5
IBM Cabling System
Types 2A and 6A
Description
UL NEC/
No.
Part
C(UL) CEC
of
No.
Type
Pairs
Standard Lengths
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
AWG
(stranding)
Shielding
Diameter
Inch mm Nom. DCR
Nominal
Maximum
Nom. Capacitance
Freq. Attenuation
Imped.
(MHz) (dB/
(dB/
*
*
(Ω) pF/Ft.
pF/m
1000′) 100m)
Min.
NEXT
(dB/
(dB/
3280′) 1000m)
IBM Type 2A • 22 AWG Solid Bare Copper Conductors • Each Pair Individually Beldfoil® Shielded + Overall TC Braid Shield (65% Coverage)
Non-Plenum • Flame-retardant Foam Polyethylene Insulation • Black PVC Jacket
IBM Part No.
4716739
33G2773
9689
NEC:
CMG
CEC:
CMG
6▲
1000†
3600†
304.8 80.0 36.4 .324 8.23
x
x
1097.6 298.8 135.8
.466 11.84
22
(solid)
BC
.026″
16.7Ω/M′
54.7Ω/km
100%
150
8.5
Beldfoil @ 1MHz (data)
(data)
Each Pair
+ 65%
600
TC Braid @ 1kHz
Overall
(voice)
27.9
(data)
(data only)
1k** .390
4
6.7
16
13.4
100
37.5
300
65.2
100†† 40.8
300†† 71.0
600†† 100.3
.128
2.2
4.4
12.3
21.4
13.4
23.3
32.9
—
58.0
50.4
38.5
31.3
—
—
—
—
58.0
50.4
38.5
31.3
—
—
—
Rip Cord
For Plenum version of 9689,
see 82689.
IBM qualified Type 2A Media cable for use in IBM Cabling Systems.
Plenum • Foam FEP Teflon® Insulation • Black Flamarrest® Jacket
IBM Part No.
4716738
33G8221
82689
NEC:
CMP
CEC:
CMP
6▲
1000 †
304.8
79.0 35.9 .324 8.23
x
x
.460 11.68
22
(solid)
BC
.026″
16.7Ω/M′
54.7Ω/km
100%
150
8.5
Beldfoil @ 1MHz (data)
Each Pair (data)
+ 65%
600
TC Braid @ 1kHz
Overall
(voice)
27.9
(data)
(data only)
1k** .390
4
6.7
16
13.4
100
37.5
300
65.2
100†† 40.8
††
300
71.0
600†† 100.3
.128
2.2
4.4
12.3
21.4
13.4
23.3
32.9
—
58.0
50.4
38.5
31.3
—
—
—
—
58.0
50.4
38.5
31.3
—
—
—
Rip Cord
IBM qualified Type 2A Media cable for use in IBM Cabling Systems.
IBM Type 6A • 26 AWG Stranded (7x34) BC Conductors • Twisted Pairs • Beldfoil Shielded Pairs + Overall TC Braid Shield (65% Coverage)
Non-Plenum • Datalene® Insulation • Striated Black PVC Jacket
IBM Part No.
4716743
33G2775
1215A
NEC:
CL2, CM
CEC:
CM
2
1000 †
304.8
46.0 20.9 .325 8.26
26
(7x34)
BC
.019″
38.7Ω/M′
127.0Ω/km
100%
Beldfoil
Each Pair
+ 65%
TC Braid
Overall
150
8.5
27.9
4
16
100
300
10
20
57
100
3.3
6.6
18.7
32.3
52.0
44.0
33.0
25.0
52.0
44.0
33.0
25.0
IBM qualified Type 6A Office cable for use in IBM Cabling Systems.
BC = Bare Copper • DCR = DC Resistance • NEXT = Near-end Crosstalk • TC = Tinned Copper
* Capacitance between conductors
**Voice pairs (1 kHz); Data pairs (4–600 MHz)
† Spools are one piece, but length may vary ±10% from length shown.
†† Common mode
▲
(2) shielded Data-grade pairs; (4) unshielded Voice-grade media pairs
Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800-BELDEN-1.
Teflon is a DuPont trademark.
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.81
IBM RISC System / 6000
Description
Part
No.
No.
UL NEC/
of
C(UL) CEC
Pairs/
Type
Cond.
Standard Lengths
Ft.
m
Standard
Unit Wt.
Lbs.
kg
Nominal
OD
Inch
mm
AWG
(stranding)
Material
Nom. DCR
Shielding
Material
Nom. DCR
Nom.
Imped.
(Ω)
Nominal Capacitance
*
pF/Ft.
*
pF/m
**
pF/Ft.
**
pF/m
28 AWG Stranded (7x36) Bare Copper Conductors • Twisted Pairs • Overall Beldfoil® Shielded + TC Braid Shield (65% Coverage) • TC Drain Wire
Non-Plenum • Patented Step Polyolefin Insulation • Gray PVC Jacket (See RISC Color Code Chart below)
IBM Part No.
N Cable
1538A
NEC:
CL2
3
U-1000
1000
U-304.8
304.8
24.0
25.0
10.9
11.4
.225
5.72
28
(7x36)
Bare Copper
63.0Ω/M′
207.0Ω/km
Overall
Beldfoil
+ 65%
TC Braid
5.5Ω/M′
18.0Ω/km
120
12.0
39.4
21.5
70.5
1540A
NEC:
CL2
7/c
U-1000
1000
U-304.8
304.8
21.0
21.0
9.5
9.5
.190
4.83
28
(7x36)
Bare Copper
63.0Ω/M′
207.0Ω/km
Overall
Beldfoil
+ 65%
TC Braid
7.2Ω/M′
23.6Ω/km
—
12.5
41.0
23.0
75.5
IBM Part No.
XX, YY Cable
RJ-45 compatible
DC = DC Resistance • TC = Tinned Copper
* Capacitance between conductors
**Capacitance between one conductor and other conductors connected to shield
Color Codes: IBM RISC System / 6000
Cond.
Color
Pair No. Color Combination
1st
White over Blue
2nd
White over Orange
3rd
White over Green
4th
White over Brown
5th
White over Gray
6th
White over Red
7th
White over Yellow
1
White over Blue &
Blue over White
2
White over Orange &
Orange over White
3
White over Green &
Green over White
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
15 • Networking — Copper
RJ-45 compatible
C O M M E R C I A L
N E T W O R K I N G
—
C O P P E R
15.82
SCSI 25- and 34-Pair Cable
(Small Computer System Interface)
Description
Part
No.
UL NEC/
C(UL) CEC
Type
No.
of
Pairs
Standard Lengths
Ft.
m
Standard
Unit Weight
Lbs.
kg
Nominal
OD
Inch
mm
AWG
Nominal Capacitance
Shielding Nom. Nom.
(stranding) Material Imped. Vel.
Material
of
*
*
**
**
(Ω) Prop. pF/Ft. pF/m
pF/Ft. pF/m
Nom. DCR Nom. DCR
SCSI • 28 AWG Stranded (7x36) TC Conductors • Twisted Pairs • Overall Beldfoil® Shield + TC Braid Shield (85% Coverage) • See Color Code Chart (below)
Non-Plenum • Flame-retardant Polyolefin Insulation • Polypropylene Buffer Layer • Light Gray PVC Jacket
150V
1401A
NEC:
CL2,
CMG
CEC:
CMG
25
500
1000
152.4
304.8
51.5
101.0
23.4
45.9
.420
10.7
28
(7x36)
TC
64.9Ω/M′
212.9Ω/km
Overall
Beldfoil
+ 85%
TC Braid
2.0Ω/M′
6.6Ω/km
120†
80††
66%
12.7
41.7
30.0
98.4
150V
1403A
NEC:
CL2, CM
CEC:
CM
34
500
1000
152.4
304.8
71.5
139.0
32.5
63.2
.480
12.2
28
(7x36)
TC
64.9Ω/M′
212.2Ω/km
Overall
Beldfoil
+ 85%
TC Braid
1.5Ω/M′
4.9Ω/km
120†
80††
66%
12.7
41.7
30.0
98.4
DCR = DC Resistance • TC = Tinned Copper
* Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
† Differential mode impedance.
†† Single end mode termination impedance.
Color Codes: Modified Western Electric Standard
Pair No.
1
2
3
4
5
6
7
8
Color Combination
White/Blue Stripe &
Blue/White Stripe
White/Orange Stripe &
Orange/White Stripe
White/Green Stripe &
Green/White Stripe
White/Brown Stripe &
Brown/White Stripe
White/Gray Stripe &
Gray/White Stripe
Red/Blue Stripe &
Blue/Red Stripe
Red/Orange Stripe &
Orange/Red Stripe
Red/Green Stripe &
Green/Red Stripe
Pair No.
9
10
11
12
13
14
15
16
Color Combination
Red/Brown Stripe &
Brown/Red Stripe
Red/Gray Stripe &
Gray/Red Stripe
Black/Blue Stripe &
Blue/Black Stripe
Black/Orange Stripe &
Orange/Black Stripe
Black/Green Stripe &
Green/Black Stripe
Black/Brown Stripe &
Brown/Black Stripe
Black/Gray Stripe &
Gray/Black Stripe
Yellow/Blue Stripe &
Blue/Yellow Stripe
Pair No.
17
18
19
20
21
22
23
24
Color Combination
Yellow/Orange Stripe &
Orange/Yellow Stripe
Yellow/Green Stripe &
Green/Yellow Stripe
Yellow/Brown Stripe &
Brown/Yellow Stripe
Yellow/Gray Stripe &
Gray/Yellow Stripe
Purple/Blue Stripe &
Blue/Purple Stripe
Purple/Orange Stripe &
Orange/Purple Stripe
Purple/Green Stripe &
Green/Purple Stripe
Purple/Brown Stripe &
Brown/Purple Stripe
Pair No.
25
26
27
28
29
30
31
32
33
34
Color Combination
Purple/Gray Stripe &
Gray/Purple Stripe
White & Blue No.
White & Orange
White & Green
White & Brown
White & Gray
Red & Blue
Red & Orange
Red & Green
Red & Brown
F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement