For technici - GHV Trading
vez l’ensemble de l’offre
d’automatismes pour répondre
es les exigences des secteurs
ie, énergie, ferroviaire…
FR
2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex - France
Tel.: +33 1 75 60 10 30
Fax: +33 1 46 66 62 54
[email protected] - www.enerdis.fr
LILLE
Tel.: 03 20 55 96 41 - Fax: 03 20 06 33 61
[email protected]
NANTES
Tel.: 02 40 84 01 16 - Fax: 02 40 75 35 55
[email protected]
LYON
Tel.: 04 72 65 77 60 - Fax: 04 78 03 15 39
[email protected]
PARIS
Tel.: 01 44 85 45 75 - Fax: 01 46 27 07 48
[email protected]
NANCY
Tel.: 03 83 92 19 21 - Fax: 03 83 90 32 11
[email protected]
TOULOUSE
Tel.: 05 62 74 50 30 - Fax: 05 61 71 45 06
[email protected]
For professionals like you: contractors,
technicians and engineers in the electrical sector
international
Measuring instruments
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
Tel.: +33 1 44 85 44 38 - Fax: +33 1 46 27 95 59
[email protected] - www.chauvin-arnoux.fr
n For electrical installation testing
n For maintenance of industrial
electrical and electronic systems
n For metrology: precision measurements
n For design work: research and
development
10 subsidiaries spread across the world
GERMANY
CHAUVIN ARNOUX GMBH
Ohmstraße 1
77694 KEHL / RHEIN
Tel.: +49 7851 99 26-0 - Fax: +49 7851 99 26-60
[email protected]
www.chauvin-arnoux.de
Catalogue Pyro Capteurs 2013.indd 1
05/02/2013 09:03:14
PYROCONTROLE
6 bis, av du Docteur Schweitzer
69881 MEYZIEU Cedex - France
Tel.: +33 4 72 14 15 40
Fax: +33 4 72 14 15 41
[email protected]
www.pyrocontrole.com
MÉTROLOGIE & CONTRÔLES RÉGLEMENTAIRES
MANUMESURE
248, av des Grésillons
92600 ASNIÈRES sur SEINE - France
Tel.: +33 1 75 61 01 90
Fax: +33 1 47 33 28 02
[email protected]
www.manumesure.fr
AUSTRIA
CHAUVIN ARNOUX GES.M.B.H
Slamastrasse 29/2/4
1230 WIEN
Tel.: +43 1 61 61 9 61 - Fax: +43 1 61 61 9 61-61
[email protected]
www.chauvin-arnoux.at
CHINA
SHANGHAI PU-JIANG ENERDIS
INSTRUMENTS CO. LTD
N° 381 Xiang De Road
3 Floor, Building 1
200081 SHANGHAI
Tel.: +86 21 65 21 51 96 - Fax: +86 21 65 21 61 07
[email protected]
SPAIN
CHAUVIN ARNOUX IBÉRICA SA
C/ Roger de Flor N°293
1a Planta
08025 BARCELONA
Tel.: +34 902 20 22 26 - Fax: +34 934 59 14 43
[email protected]
www.chauvin-arnoux.es
ITALY
AMRA SPA
Via Sant’Ambrogio, 23
20846 MACHERIO (MB)
Tel.: +39 039 245 75 45 - Fax: +39 039 481 561
[email protected]
www.chauvin-arnoux.it
Test & Measurement catalog 2016
International
Tél. : +33 1 75 60 10 30
Fax : +33 1 46 66 62 54
[email protected]
Catalogue général
MIDDLE EAST
CHAUVIN ARNOUX MIDDLE EAST
PO Box 60-154
1241 2020 JAL EL DIB
(Beyrouth) - LIBAN
Tel.: +961 1 890 425 - Fax: +961 1 890 424
[email protected]
www.chauvin-arnoux.com
UNITED KINGDOM
CHAUVIN ARNOUX LTD
Unit 1 Nelson Ct, Flagship Sq
Shaw Cross Business Pk, Dewsbury
West Yorkshire - WF12 7TH
Tel.: +44 1924 460 494 - Fax: +44 1924 455 328
[email protected]
www.chauvin-arnoux.com
SCANDINAVIA
CA MÄTSYS TEM AB
Sjöflygvägen 35
SE-183 62 TABY
Tel.: +46 8 50 52 68 00 - Fax: +46 8 50 52 68 10
[email protected]
www.camatsystem.com
From design through
to industrialization
n Measurement of electrical quantities
in total safety
Rugged, reliable, portable
instruments which are high-quality,
safe and easy to use
n Sales agencies and staff at your service
n Technical centres: calibration and repairs
n A multi-product website and mini-sites
dedicated to specific product ranges
SWITZERLAND
CHAUVIN ARNOUX AG
Moosacherstrasse 15
8804 AU / ZH
Tel.: +41 44 727 75 55 - Fax: +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
USA
CHAUVIN ARNOUX INC
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tel.: +1 (508) 698-2115 - Fax: +1 (508) 698-2118
[email protected]
www.aemc.com
Expertise
n Technical support, training,
mock-ups, etc.
Metrix is a brand of Chauvin Arnoux
A response based on instruments designed,
developed, manufactured and checked by professionals
in the electrical sector
906 131 117
France
Tél. : 01 75 60 10 30
Fax : 01 46 66 62 54
[email protected]
Catalogue général 2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex
www.enerdis.fr
906 130 080 - Ed. 9 - 12/2014 - Document non contractuel - Caractéristiques à se faire confirmer à la commande - Photos et shémas non contractuels.
USA
Chauvin Arnoux Inc
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tél. : +1 (508) 698-2115
Fax : +1 (508) 698-2118
[email protected]
www.aemc.com
UN CONTACT
CENTRALISÉ
Multimeters, clamps,
testers and laboratory instruments
A STRUCTURE BASED ON LOCAL AGENCIES IN FRANCE
SUISSE
Chauvin Arnoux AG
Einsiedlerstrasse 535
8810 HORGEN
Tél. : +41 44 727 75 55
Fax : +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
[email protected] - www.metrix.fr
GB
GB
GB
vez l’ensemble de l’offre
d’automatismes pour répondre
es les exigences des secteurs
ie, énergie, ferroviaire…
FR
2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex - France
Tel.: +33 1 75 60 10 30
Fax: +33 1 46 66 62 54
[email protected] - www.enerdis.fr
LILLE
Tel.: 03 20 55 96 41 - Fax: 03 20 06 33 61
[email protected]
NANTES
Tel.: 02 40 84 01 16 - Fax: 02 40 75 35 55
[email protected]
LYON
Tel.: 04 72 65 77 60 - Fax: 04 78 03 15 39
[email protected]
PARIS
Tel.: 01 44 85 45 75 - Fax: 01 46 27 07 48
[email protected]
NANCY
Tel.: 03 83 92 19 21 - Fax: 03 83 90 32 11
[email protected]
TOULOUSE
Tel.: 05 62 74 50 30 - Fax: 05 61 71 45 06
[email protected]
For professionals like you: contractors,
technicians and engineers in the electrical sector
international
Measuring instruments
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
Tel.: +33 1 44 85 44 38 - Fax: +33 1 46 27 95 59
[email protected] - www.chauvin-arnoux.fr
n For electrical installation testing
n For maintenance of industrial
electrical and electronic systems
n For metrology: precision measurements
n For design work: research and
development
10 subsidiaries spread across the world
GERMANY
CHAUVIN ARNOUX GMBH
Ohmstraße 1
77694 KEHL / RHEIN
Tel.: +49 7851 99 26-0 - Fax: +49 7851 99 26-60
[email protected]
www.chauvin-arnoux.de
Catalogue Pyro Capteurs 2013.indd 1
05/02/2013 09:03:14
PYROCONTROLE
6 bis, av du Docteur Schweitzer
69881 MEYZIEU Cedex - France
Tel.: +33 4 72 14 15 40
Fax: +33 4 72 14 15 41
[email protected]
www.pyrocontrole.com
MÉTROLOGIE & CONTRÔLES RÉGLEMENTAIRES
MANUMESURE
248, av des Grésillons
92600 ASNIÈRES sur SEINE - France
Tel.: +33 1 75 61 01 90
Fax: +33 1 47 33 28 02
[email protected]
www.manumesure.fr
AUSTRIA
CHAUVIN ARNOUX GES.M.B.H
Slamastrasse 29/2/4
1230 WIEN
Tel.: +43 1 61 61 9 61 - Fax: +43 1 61 61 9 61-61
[email protected]
www.chauvin-arnoux.at
CHINA
SHANGHAI PU-JIANG ENERDIS
INSTRUMENTS CO. LTD
N° 381 Xiang De Road
3 Floor, Building 1
200081 SHANGHAI
Tel.: +86 21 65 21 51 96 - Fax: +86 21 65 21 61 07
[email protected]
SPAIN
CHAUVIN ARNOUX IBÉRICA SA
C/ Roger de Flor N°293
1a Planta
08025 BARCELONA
Tel.: +34 902 20 22 26 - Fax: +34 934 59 14 43
[email protected]
www.chauvin-arnoux.es
ITALY
AMRA SPA
Via Sant’Ambrogio, 23
20846 MACHERIO (MB)
Tel.: +39 039 245 75 45 - Fax: +39 039 481 561
[email protected]
www.chauvin-arnoux.it
Test & Measurement catalog 2016
International
Tél. : +33 1 75 60 10 30
Fax : +33 1 46 66 62 54
[email protected]
Catalogue général
MIDDLE EAST
CHAUVIN ARNOUX MIDDLE EAST
PO Box 60-154
1241 2020 JAL EL DIB
(Beyrouth) - LIBAN
Tel.: +961 1 890 425 - Fax: +961 1 890 424
[email protected]
www.chauvin-arnoux.com
UNITED KINGDOM
CHAUVIN ARNOUX LTD
Unit 1 Nelson Ct, Flagship Sq
Shaw Cross Business Pk, Dewsbury
West Yorkshire - WF12 7TH
Tel.: +44 1924 460 494 - Fax: +44 1924 455 328
[email protected]
www.chauvin-arnoux.com
SCANDINAVIA
CA MÄTSYS TEM AB
Sjöflygvägen 35
SE-183 62 TABY
Tel.: +46 8 50 52 68 00 - Fax: +46 8 50 52 68 10
[email protected]
www.camatsystem.com
From design through
to industrialization
n Measurement of electrical quantities
in total safety
Rugged, reliable, portable
instruments which are high-quality,
safe and easy to use
n Sales agencies and staff at your service
n Technical centres: calibration and repairs
n A multi-product website and mini-sites
dedicated to specific product ranges
SWITZERLAND
CHAUVIN ARNOUX AG
Moosacherstrasse 15
8804 AU / ZH
Tel.: +41 44 727 75 55 - Fax: +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
USA
CHAUVIN ARNOUX INC
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tel.: +1 (508) 698-2115 - Fax: +1 (508) 698-2118
[email protected]
www.aemc.com
Expertise
n Technical support, training,
mock-ups, etc.
Metrix is a brand of Chauvin Arnoux
A response based on instruments designed,
developed, manufactured and checked by professionals
in the electrical sector
906 131 117
France
Tél. : 01 75 60 10 30
Fax : 01 46 66 62 54
[email protected]
Catalogue général 2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex
www.enerdis.fr
906 130 080 - Ed. 9 - 12/2014 - Document non contractuel - Caractéristiques à se faire confirmer à la commande - Photos et shémas non contractuels.
USA
Chauvin Arnoux Inc
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tél. : +1 (508) 698-2115
Fax : +1 (508) 698-2118
[email protected]
www.aemc.com
UN CONTACT
CENTRALISÉ
Multimeters, clamps,
testers and laboratory instruments
A STRUCTURE BASED ON LOCAL AGENCIES IN FRANCE
SUISSE
Chauvin Arnoux AG
Einsiedlerstrasse 535
8810 HORGEN
Tél. : +41 44 727 75 55
Fax : +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
[email protected] - www.metrix.fr
GB
GB
GB
CONTENTS
index by reference
The Group: History & Values…
Selection guide for on-site oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . 65
OX 5022 & OX 5042 Handscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
SCOPIX family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SCOPIX for industrial maintenance: OX 7042 & OX 7104 . . . . . . . . . 70
SCOPIX for electronics: OX 7062, OX 7102, OX 7104,
OX 7202 & OX 7204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Scopix Fieldbus: OX 7202BUS & OX 7204BUS . . . . . . . . . . . . . . . . . . . 72
PROBIX accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
OX software accessories: SX METRO & virtual printer . . . . . . . . . . . . 76
OX software accessories: SCOPE ADMIN & SCOPENET . . . . . . . . . . . 77
Innovations, Ergonomics & Awards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Illustrated Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Testers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SMD Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LF electric field testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Voltage tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Multimeters
On-site multimeter selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MX1 & MX2B analogue on-site multimeters . . . . . . . . . . . . . . . . . . . . . . 13
Digital on-site multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MTX 202 & MTX 203 family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MX Concept RMS family: MX 24, MX 24B & MX 26 . . . . . . . . . . . . . . 18
• ATEX MX 57Ex for difficult environments . . . . . . . . . . . . . . . . . . . . . 20
• ASYC IV family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• MTX 3290 & MTX 3291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
• MTX 3292 & MTX 3293 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
• Clamps for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MX 5006 & MX 5060 laboratory multimeters . . . . . . . . . . . . . . . . . . . 30
Spectrum analyser connected to PC: MTX 1050 . . . . . . . . . . . . . . . . . 80
EMC prequalification: HX 0082 & HX 0083 . . . . . . . . . . . . . . . . . . . . . . 82
Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Technological Breakthroughs and Patented
Discoveries
As a French brand known nationwide by generations of electricians and electronic engineers,
to the point of becoming the generic name for multimeters in France, Metrix® is Chauvin Arnoux’s
flagship brand in electronics for multimeters, oscilloscopes, power supplies and generators.
The Engineering Department and R&D teams are still based on the site at Annecy-le-Vieux,
but they can now take full advantage of the high-performance industrialization tools on the Group’s
production sites in Normandy.
Generator selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
LF generators: GX 305, GX 310 & GX 320 . . . . . . . . . . . . . . . . . . . . . . . 86
GX 1025 & GX 1050 generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Metrix: from the lampmeter, the electro-clamp
and oscilloscopes to “the Metrix”
Laboratory power supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
AX 501, AX 502 & AX 503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
AX 1360-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Software for multimeters
SX-DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SX-ASYC2C/B, MX 57EX-CAL & HX 0059 . . . . . . . . . . . . . . . . . . . . . . . 33
Communication accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
In 1936, Georges Friédrichs founded a small
company named CARTEX. This company enjoyed
considerable growth during the years of economic
expansion following the Second World War.
Training equipment (shunts, etc.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
CX 1651 multi-function laboratory calibrator . . . . . . . . . . . . . . . . . . . . 94
Multimeter clamps
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
350-355 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
650-655 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
670-675 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Accessories
PX 110 & PX 120 wattmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
MX 98 cos-phimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
AC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Flexible AC current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
AC/DC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Current clamps for specific requirements . . . . . . . . . . . . . . . . . . . . . . . 101
Generic cables and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
K-thermocouple and Pt100 probes and sensors . . . . . . . . . . . . . . . . . 104
Transport and protection accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Electrical safety testers
Insulation testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
MX 406B & MX 604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
MX 407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MX 435D multi-function installation tester . . . . . . . . . . . . . . . . . . . . . . 44
Training equipment
Analogue voltmeter & ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
1950: launch of the MX 460…
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Voltage probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
MX 9030, MTX 1032B & MTX 1032C differential voltage probes . . . 110
Insulated current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Flexible current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Coaxial accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Transport and protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Oscilloscopes
Introduction to analogue oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . 46
Introduction to digital oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Selection guide for analogue and [email protected] oscilloscopes . . . . . . . . 49
[email protected] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
MTX 162 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
MTX 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MTX 1052 & MTX 1054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
OX 530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Index
By product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
By function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
By reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
…and the MX 400 electro-clamp
Selection guide for benchtop digital oscilloscopes
DOX 2000 & OX 6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
OX 6062B, OX 6202 & OXi 6204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
DOX 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
DOX 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Software for benchtop oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
USB
Power
Diode test
Frequency
Smart
persistence
oscilloscope
IEC 61010
electrical safety
Ethernet
Capacitance
Min, Max,
Avg and PEAK
Resistance
Fourier
transform
IEC 61010
electrical safety
Android
Current
Measurement with
current clamp
Reactive
power
Multimeter
2.5 or 50-kpoint
memory depth
Recording
Continuity
3 sockets
Apparent
power
MATH
functions
50-kpoint
memory depth
Temperature
Voltage
Decibel
Harmonics
2-Mpoint
memory depth
Protection rating
ASYC IV 100-kcount colour graphical
multimeter
Its main business was manufacturing portable
“lampmeters” for checking the valves used in the
radioelectricity sector, which was growing fast
at the time. With the rising demand for electrical
and electronic measurement equipment, CARTEX
quickly became a major player in this sector, with
products such as the lampmeter, testers and
frequency generators. In 1946, it changed its name
to “Compagnie Générale de Métrologie” (General
Metrology Company) and began marketing its
products under the Metrix brand.
Reference
P01120083
P01120301
P01120303
P01120304
P01120305
P01120308
P01120309
P01120401
P01120402
P01120402
P01120405
P01120409
P01120415
P01120416
P01120421
P01120421
P01120501
P01120502
P01120503
P01120504
P01120505
P01120506
P01120507
P01120508
P01120509
P01120560
P01120561
P01120562
P01120563
P01120564
P01120565
P01120570
P01120571
P01120572
P01196770
P01196770
P01197401
P01197402
P01197403
P01197404
P01295073A
P01295073A
Page
97
94
94
94
94
108
97
94
11
94
94
108
94
94
44
97
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
109
109
109
32
33
93
93
93
93
89
110
Reference
P01295288Z
P01295289Z
P01295290Z
P01295293
P01295450Z
P01295451Z
P01295452Z
P01295453Z
P01295454Z
P01295455Z
P01295456Z
P01295457Z
P01295458Z
P01295459Z
P01295460Z
P01298004
P01298068
P01298069
P01298071
P01298072
P01330401
P01637301
P01651610Z
P01652401Z
P01652411Z
P03197521A
P03197522A
P03197523A
P03197524A
P03197525A
P03197526A
P03197527A
P03197528A
P03295509
P03652712
P03652713
P03652714
P03652715
P03652901
P03652902
P03652903
P03652904
Page
98
98
98
33
102
102
102
102
102
102
102
102
102
99
98
107
107
107
107
107
39
34
67
67
67
93
93
93
93
93
93
93
93
39
105
105
105
105
104
104
104
104
Reference
P03652905
P03652906
P03652907
P03652908
P03652909
P03652910
P03652913
P03652914
P03652917
P03652918
P03652919
P03652920
P03652921
P03652922
P06239307
PA4119-50
PX0110
PX0120
Page
104
104
104
104
104
104
104
104
104
104
104
104
104
104
99
110
39
39
S
SX-ACQ.V2
SX-ASYC2C/B
SX-ASYC2HD
SX-DMM2
SX-DMMBT/B
SX-DMMK2
SX-PROG.1
28
33
33
33
33
33
33
T
TX0001-Z
TX001-Z
10,11
10
V
VX0003
VX0100
11
11
The launch of the “electro-clamp”, allowing users to
check voltages without disconnecting and measure
high currents with one hand, and the production
of oscilloscopes from 1948 onwards helped to
quickly expand the company’s offering. However,
the products that really made the brand’s reputation
were the MX 460, launched in 1950, and more
particularly, the MX 462 multimeter, which was so
successful that “Metrix®” became the generic name
for multimeters in France, enabling the company to
grow very fast.
121
CONTENTS
index by reference
The Group: History & Values…
Selection guide for on-site oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . 65
OX 5022 & OX 5042 Handscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
SCOPIX family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SCOPIX for industrial maintenance: OX 7042 & OX 7104 . . . . . . . . . 70
SCOPIX for electronics: OX 7062, OX 7102, OX 7104,
OX 7202 & OX 7204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Scopix Fieldbus: OX 7202BUS & OX 7204BUS . . . . . . . . . . . . . . . . . . . 72
PROBIX accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
OX software accessories: SX METRO & virtual printer . . . . . . . . . . . . 76
OX software accessories: SCOPE ADMIN & SCOPENET . . . . . . . . . . . 77
Innovations, Ergonomics & Awards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Illustrated Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Testers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SMD Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LF electric field testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Voltage tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Multimeters
On-site multimeter selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MX1 & MX2B analogue on-site multimeters . . . . . . . . . . . . . . . . . . . . . . 13
Digital on-site multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MTX 202 & MTX 203 family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MX Concept RMS family: MX 24, MX 24B & MX 26 . . . . . . . . . . . . . . 18
• ATEX MX 57Ex for difficult environments . . . . . . . . . . . . . . . . . . . . . 20
• ASYC IV family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• MTX 3290 & MTX 3291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
• MTX 3292 & MTX 3293 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
• Clamps for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MX 5006 & MX 5060 laboratory multimeters . . . . . . . . . . . . . . . . . . . 30
Spectrum analyser connected to PC: MTX 1050 . . . . . . . . . . . . . . . . . 80
EMC prequalification: HX 0082 & HX 0083 . . . . . . . . . . . . . . . . . . . . . . 82
Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Technological Breakthroughs and Patented
Discoveries
As a French brand known nationwide by generations of electricians and electronic engineers,
to the point of becoming the generic name for multimeters in France, Metrix® is Chauvin Arnoux’s
flagship brand in electronics for multimeters, oscilloscopes, power supplies and generators.
The Engineering Department and R&D teams are still based on the site at Annecy-le-Vieux,
but they can now take full advantage of the high-performance industrialization tools on the Group’s
production sites in Normandy.
Generator selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
LF generators: GX 305, GX 310 & GX 320 . . . . . . . . . . . . . . . . . . . . . . . 86
GX 1025 & GX 1050 generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Metrix: from the lampmeter, the electro-clamp
and oscilloscopes to “the Metrix”
Laboratory power supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
AX 501, AX 502 & AX 503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
AX 1360-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Software for multimeters
SX-DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SX-ASYC2C/B, MX 57EX-CAL & HX 0059 . . . . . . . . . . . . . . . . . . . . . . . 33
Communication accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
In 1936, Georges Friédrichs founded a small
company named CARTEX. This company enjoyed
considerable growth during the years of economic
expansion following the Second World War.
Training equipment (shunts, etc.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
CX 1651 multi-function laboratory calibrator . . . . . . . . . . . . . . . . . . . . 94
Multimeter clamps
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
350-355 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
650-655 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
670-675 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Accessories
PX 110 & PX 120 wattmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
MX 98 cos-phimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
AC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Flexible AC current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
AC/DC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Current clamps for specific requirements . . . . . . . . . . . . . . . . . . . . . . . 101
Generic cables and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
K-thermocouple and Pt100 probes and sensors . . . . . . . . . . . . . . . . . 104
Transport and protection accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Electrical safety testers
Insulation testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
MX 406B & MX 604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
MX 407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MX 435D multi-function installation tester . . . . . . . . . . . . . . . . . . . . . . 44
Training equipment
Analogue voltmeter & ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
1950: launch of the MX 460…
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Voltage probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
MX 9030, MTX 1032B & MTX 1032C differential voltage probes . . . 110
Insulated current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Flexible current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Coaxial accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Transport and protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Oscilloscopes
Introduction to analogue oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . 46
Introduction to digital oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Selection guide for analogue and [email protected] oscilloscopes . . . . . . . . 49
[email protected] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
MTX 162 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
MTX 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MTX 1052 & MTX 1054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
OX 530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Index
By product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
By function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
By reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
…and the MX 400 electro-clamp
Selection guide for benchtop digital oscilloscopes
DOX 2000 & OX 6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
OX 6062B, OX 6202 & OXi 6204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
DOX 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
DOX 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Software for benchtop oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
USB
Power
Diode test
Frequency
Smart
persistence
oscilloscope
IEC 61010
electrical safety
Ethernet
Capacitance
Min, Max,
Avg and PEAK
Resistance
Fourier
transform
IEC 61010
electrical safety
Android
Current
Measurement with
current clamp
Reactive
power
Multimeter
2.5 or 50-kpoint
memory depth
Recording
Continuity
3 sockets
Apparent
power
MATH
functions
50-kpoint
memory depth
Temperature
Voltage
Decibel
Harmonics
2-Mpoint
memory depth
Protection rating
ASYC IV 100-kcount colour graphical
multimeter
Its main business was manufacturing portable
“lampmeters” for checking the valves used in the
radioelectricity sector, which was growing fast
at the time. With the rising demand for electrical
and electronic measurement equipment, CARTEX
quickly became a major player in this sector, with
products such as the lampmeter, testers and
frequency generators. In 1946, it changed its name
to “Compagnie Générale de Métrologie” (General
Metrology Company) and began marketing its
products under the Metrix brand.
Reference
P01120083
P01120301
P01120303
P01120304
P01120305
P01120308
P01120309
P01120401
P01120402
P01120402
P01120405
P01120409
P01120415
P01120416
P01120421
P01120421
P01120501
P01120502
P01120503
P01120504
P01120505
P01120506
P01120507
P01120508
P01120509
P01120560
P01120561
P01120562
P01120563
P01120564
P01120565
P01120570
P01120571
P01120572
P01196770
P01196770
P01197401
P01197402
P01197403
P01197404
P01295073A
P01295073A
Page
97
94
94
94
94
108
97
94
11
94
94
108
94
94
44
97
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
109
109
109
32
33
93
93
93
93
89
110
Reference
P01295288Z
P01295289Z
P01295290Z
P01295293
P01295450Z
P01295451Z
P01295452Z
P01295453Z
P01295454Z
P01295455Z
P01295456Z
P01295457Z
P01295458Z
P01295459Z
P01295460Z
P01298004
P01298068
P01298069
P01298071
P01298072
P01330401
P01637301
P01651610Z
P01652401Z
P01652411Z
P03197521A
P03197522A
P03197523A
P03197524A
P03197525A
P03197526A
P03197527A
P03197528A
P03295509
P03652712
P03652713
P03652714
P03652715
P03652901
P03652902
P03652903
P03652904
Page
98
98
98
33
102
102
102
102
102
102
102
102
102
99
98
107
107
107
107
107
39
34
67
67
67
93
93
93
93
93
93
93
93
39
105
105
105
105
104
104
104
104
Reference
P03652905
P03652906
P03652907
P03652908
P03652909
P03652910
P03652913
P03652914
P03652917
P03652918
P03652919
P03652920
P03652921
P03652922
P06239307
PA4119-50
PX0110
PX0120
Page
104
104
104
104
104
104
104
104
104
104
104
104
104
104
99
110
39
39
S
SX-ACQ.V2
SX-ASYC2C/B
SX-ASYC2HD
SX-DMM2
SX-DMMBT/B
SX-DMMK2
SX-PROG.1
28
33
33
33
33
33
33
T
TX0001-Z
TX001-Z
10,11
10
V
VX0003
VX0100
11
11
The launch of the “electro-clamp”, allowing users to
check voltages without disconnecting and measure
high currents with one hand, and the production
of oscilloscopes from 1948 onwards helped to
quickly expand the company’s offering. However,
the products that really made the brand’s reputation
were the MX 460, launched in 1950, and more
particularly, the MX 462 multimeter, which was so
successful that “Metrix®” became the generic name
for multimeters in France, enabling the company to
grow very fast.
121
Healthy Rivalry
Based in Annecy, the company continued to expand, boosting the local economy, but Metrix’s success and
expertise in the measurement field quickly drew the attention of large industrial companies and, in 1964,
ITT International (International Telegraph and Telephone) took over the company and incorporated it into
its instrumentation division to develop analogue and digital multimeters.
With the development of the instrumentation
market, the spread of information technology
offering new possibilities, the increasingly
international competition and the changes in the
technological and standardization requirements,
Metrix joined the
Chauvin Arnoux Group
in 1997.
This was followed by
several years of goodnatured competition
between Chauvin
Arnoux’s teams and the
Metrix R&D Department.
This gave rise to product
ranges such as the MTX
Concept multimeters, Scopix
oscilloscopes and the MTX
Mobile generation of products,
as well as the ASYC IV Series
more recently.
Today, Chauvin Arnoux and
Metrix® have merged to offer
a complete range of portable
and laboratory instruments
for electricians and electronic
engineers, covering all our
customers’ needs.
MX 24B
OX 5042
The MX 135 analogue multimeter
Scopix OX 7104
ASYC IV MTX 3292 colour
graphical 100-kcount
multimeter
Digital multimeters, oscilloscopes and function generators are designed under the Metrix® brand
renowned for its innovations in terms of design, ergonomics and technology. As the inventor of
the key switch (MTX mobile®), the smallest oscilloscope with isolated channels on the market
(Handscope®) "flip" multimeter (MTX mobile®), the brand’s instruments regularly win awards for their
innovative features.
1
Chauvin Arnoux is an industrial group
with a comprehensive offering covering
the whole measurement sector
Education
Three French companies, Chauvin Arnoux, Pyrocontrole and Enerdis, offer expertise in portable
instrumentation, thermal processes and electrical equipment, and energy efficiency solutions, respectively.
90 % of the products are designed and manufactured entirely in one of Group’s six Research and
Development centres. Chauvin Arnoux benefits from production sites mainly based in Normandy, France.
Every year, it proposes a palette of more than 5,000 product references to meet the needs of contractors,
government authorities and major customers in industry.
Integrated service!
EcoDesign
Alongside this extensive, comprehensive offering,
12 agencies under the Manumesure brand provide
high-quality, nationwide metrology and regulatory
testing services (repairs, metrological verification,
pollution measurement, etc.). This expertise is
also provided internationally via the ten local
subsidiaries.
For several years now, the Group has been
implementing an ecologically-responsible approach
intended to reconcile protection of the environment
and the economic imperatives. The Chauvin
Arnoux Group’s EcoConception (ecodesign) label
highlights the company’s commitment to recycling
and recovery of products from the design phase
onwards.
Electricity, electronics, physics, industrial maintenance
& the environment: disciplines which constantly involve
measurement…
From middle schools... to higher education
When studying Science and
Technology, measurement is
essential for assessing and
understanding the theoretical
phenomena through practical
experiments. In both initial and
higher education, it is important
to determine the characteristics
of a component or system, its
behaviour in its environment
and its evolution over time, using
our measuring instruments. Our
offering covers everything from
easy-to-use instruments for initial
training through to the more
complex tools encountered by
students when they start their
working life.
h See examples in the magazine
“Les Cahiers de l’Instrumentation” (in French) which deals
with measurement in all its forms:
news, practical exercises for high
schools, reports, etc.
Initial training & Electronics
In middle schools, one of the
first tasks for students involves
measuring the electrical
quantities and then viewing the
waveform of a signal.
Multimeters or oscilloscopes with
a multimeter function are ideal
for this initial familiarization and
Design and production in-house
Every year, the Group invests nearly 10 % of its sales
revenues in Research and Development to maintain
its technological leadership and its reputation for
design and constant innovation. Designed in its R&D
centres in France, Austria and the USA, the Group’s
measuring instruments are manufactured in Chauvin
Arnoux’s factories. The plastic and metal mechanical
parts are made in Vire while the printed circuits are
etched in Villedieu. Assembly, conditioning, storage
and shipment worldwide are all handled on the
Reux (Pont-l’Évêque) site in Normandy.
h View the case studies available
on our website:
http://www.chauvin-arnoux.com/
en/notes-dapplication
Electrical Engineering classes
International presence
10 subsidiaries in Europe, the USA, China and
the Middle East, backed by export sales teams,
support the Chauvin Arnoux Group’s international
development and promote its Chauvin Arnoux,
Metrix, Multimetrix, Enerdis, Pyrocontrole, AEMC
and AMRA brands on all five continents.
All the Chauvin Arnoux Group’s sites are certified ISO 9001 and ISO 14001.
2
identification of the fundamental
characteristics: amplitude,
frequency, etc.
Visit our website: www.chauvin-arnoux.com
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
In these classes, the subjects
examined include converters,
motors, generators and
transformers. This training
includes a large number of
measurement operations
characterized by the presence
of significantly higher voltages
and currents. Understanding and
mastering electrical safety are
crucial themes.
From Voltage Absence testing
with a voltage detector
through to the multimeters
and multimeter clamps used
for TRMS measurements (AC/
DC/ AC+DC), the measuring
instruments used for recurrent
measurements are equipped
with functions ranging from the
simplest (resistance, continuity,
capacitance, etc.) to the most
complex (differential and relative
measurements, etc.).
h Professional training
As a certified training
organization since 1993,
(certification no. 11.92.06217.92),
CHAUVIN ARNOUX proposes
specific training courses. http://
www.group.chauvin-arnoux.com/
en/formations
3
Standards
New Products
EN 60529
The EN 60529 standard defines an instrument’s level of
tightness (leakproofing) to protect it from penetration by solids or water. The IP rating corresponds to the instrument’s degree of protection against penetration by solids(1st digit) and
against penetration by water (2nd digit). The higher the rating,
the greater the protection. A product without protection has a
rating of IP00 (minimum rating), while a product totally protected against penetration by solids and liquids is rated IP68
(maximum rating).
IEC 61010
This international standard defines the safety rules for electrical measuring, control and laboratory instruments. It helps to
guarantee that the design and construction of the instruments
ensure protection of users and their environment against:
electric shocks, burns, mechanical hazards, fire propagation
from these instruments, excessive temperatures, etc.
For some types of instruments, this standard is completed with
specific instructions.
The evolution of industrial and domestic equipment is increasing the hazards which may be encountered on electrical installations, with ever-higher overvoltages in particular. On LV
installations, where the voltages are limited to 1,000 Vac and
1,500 Vdc, the levels of risk are classified according to the type
of installation and voltage level.
CAT II Measurements performed on circuits connected directly
to the low-voltage installation.
Examples: domestic distribution systems, portable and domestic instruments and equipment, mains power sockets.
CAT III Measurements performed in the installation for a building.
Examples: fixed installations involved in industrial distribution
and the entry circuits for electrical maintenance in buildings
(lighting, lift/elevator, etc.).
CAT IV Measurements performed on the source of a low-voltage installation.
Examples: direct distribution, primary sources, overhead-line
and cable systems, including distribution busbars and the related equipment for protection against voltage surges.
The IEC 61010 family of international standards indicates the
safety rules for electrical measuring, control and laboratory instruments and their uses. More specifically, it is the IEC 61010-
031 standard and its amendment A1 which define the safety
rules for measuring instruments and their accessories. In the
new edition applicable from 1st March 2011, this standard was
completed with the addition of Chapter 13 which deals with
“prevention of hazards linked to short-circuits and electric
arcs”:
This modification imposes rules for work on CAT III and CAT IV
installations:
• For the test probes, the conducting part of the accessory
must not be longer than 4 mm
• For crocodile clips, the external surfaces of the jaws must be
No-conducting and the conducting parts must not be accessible when the clip is closed.
The IEC 61010-2-033 standard, whose first edition was published on 9/02/2013, brought changes concerning multimeters,
multimeter clamps, etc.
Since 9th March 2015, these instruments must ensure a level of
safety corresponding at least to 300 V CAT III.
All our products comply with the safety standards
and new products were added to the Metrix® range in
2015:
The B ASYC multimeters to complement
the ASYC IV models: a revitalized range
for your basic measurement needs
Expertise required...
IEC 61557
This international standard specifies the electrical safety
features in 1,000 Vac and 1,500 Vdc low-voltage distribution
networks. It defines all the requirements for the combined
measurement and supervision systems which measure and
monitor the electrical parameters on electrical distribution
networks. These requirements also define the performance levels on single and three-phase AC or DC networks with rated
voltages less than or equal to 1,500 Vdc.
The main parts of the IEC 61557 standard applicable to measurement and testing in our sector are:
Part 1: IEC 61557-1:General information
Part 2: IEC 61557-2:Insulation resistance
Part 3: IEC 61557-3:Loop impedance
Part 4: IEC 61557-4:Resistance of earth and equipotential bonding
Part 5: IEC 61557-5:Resistance to earth
Part 6: IEC 61557-6:
Effectiveness of the residual current devices (RCDs) in TT, TN and IT
networks
Part 7: IEC 61557-7:Phase sequence
4-CHANNEL benchtop oscilloscopes
For the electronics sector…
For electrical
engineering and
power electronics...
NF C 15-100
This is official French safety standard governing the protection
of low-voltage electrical installations and the people close to
them, as well as easy management, use and upgradeability of
the installation. Residential installations (house or apartment)
must comply with this standard.
In particular, NF C 15-100 defines the protective devices, RCDs,
wiring, number and type of lighting point, as well as the number of power sockets according to the type of room (bathroom, kitchen, etc.).
And more are on the way…
4
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
5
MULTIMETERS THEORY
MULTIMETERS THEORY
Technical reminders
Number of measurement counts
RMS: Root Mean Square
This is one of the fundamental specifications of
instruments using analogue-digital conversion. In
general, it can be used to define the measurement
range and the resolution, on the basis of the value
chosen for the rated calibre.
By definition, the RMS value of any current is the
DC current value which would cause the same
heating when flowing through a resistor.
Measurement range
In the specific case of a sinusoidal quantity,
application of the above equation yields:
This indicates the limits within which the digital
instrument maintains all its specifications, so the
indications obtained are not subject to an error
greater than the maximum tolerated error. It is
defined by a minimum value and a maximum value.
Rated calibre
The calibre of an instrument is the value of the
quantity to be measured which corresponds to
the upper limit of the measurement range. For
example, for an ammeter, if this upper limit is 5 A,
its calibre is said to be 5 A.
Peak value – Crest Factor
The amplitude (Vpeak) of a voltage or sinusoidal
current is equal to √2 times its RMS value (Vpeak
= √2 Vrms).
Knowledge of this RMS value is essential in the
industrial sector as it is this value which is used to
define a current.
Resolution
This is the smallest measurable value. It is also the
value of a measurement count or quantification
unit, usually termed "the unit".
For a sinusoidal alternating voltage
Vpeak = Vrms x √2
Vaverage = 0.9 Vrms
Minimum measurable value (or threshold)
This is the smallest measurable value. For an
instrument with good linear conversion, it may be
equal to the resolution. This is not always the case
and the manufacturer should clearly indicate it, as
this minimum value also depends on the accuracy
and, more particularly, the standard error.
When the standard error is too high, it becomes
impossible to measure very low values reliably.
This indirect measurement method is simple and
accurate, but it is only valid for sinusoidal currents
without distortion. It only tolerates distortion
amounting to a few per cent.
This is why "RMS" measuring instruments are
seeing increasing use. They are based on direct
measurement principles: thermal measurement
(used mainly in metrology) and analogue or
digital calculation methods requiring sophisticated
electronic components.
So, for the 230 V/50 Hz network:
Vrms = 230 V ; Vpeak = 325 V ; Vavg = 207 V
An "average value" measuring instrument measures
the average value of a sinusoidal current, after
rectification and filtering and displays the RMS
value after application of a coefficient equal to
1/0.9 = 1.111.
6
The crest factor is defined as follows:
CF = Vpeak / Vrms
This additional information complementing the
RMS value can be used to assess the distortion of
a signal in qualitative terms. For a sinusoidal signal,
CF = √2 = 1.414.
Advice: When we speak of a 230 V network voltage,
it is an RMS value. For many years, the linear loads
(incandescent lamps, heating) connected to the
network caused very little distortion. The spread
of No-linear loads (switching power supplies,
light dimmers, variable speed drives and compact
fluorescent lamps) is calling this approach into
question because the network's '"pure" sinusoid is
becoming increasingly rare.
Conventional measuring instruments (which give
the "effective" value on the basis of the average
value) are only accurate, by definition, with
sinusoidal currents. Otherwise the measurement
error may be as high as 50 %!
You are advised to choose RMS measuring
instruments capable of providing correct
measurements whatever the waveform of the
current or voltage.
Safety rules and good practice:
- Use measuring instruments and accessories
suitable for the application and measuring
conditions.
Prefer CAT IV instruments:
• It ensures a voltage withstand up to 50% higher
than a CAT III product
• 1,000 V CAT IV means protection against
electric shocks up to 12,000 V, while 600 V
CAT IV instruments protect up to 8,000 V.
• If you use a lower-category instrument, you
must ensure that the installation is equipped
with protective systems (disconnecting switch,
circuit breaker, etc.) which are functional and
in good condition. This is often the case... but
not always!
• For outdoor or temporary installations, or
for installations upstream of the protective
systems, CAT IV instruments are mandatory.
- It is the weakest element which defines
level of protection. If you use accessories
a lower category or voltage rating than
measuring instrument, the overall safety
offered by your measurement system is
reduced.
your
with
your
level
also
-U
se accessories in perfect condition. Any
accessories presenting even the slightest defect
must be replaced immediately because they no
longer guarantee your safety.
-F
uses are protective devices.
If you replace them with cheaper models or,
even worse, with a metal element (copper wire,
aluminium foil, etc.), they will not protect you
from possible voltage surges on the installation.
7
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
TESTERS
SMD Tester
Selection guide
Choose your tester or analogue multimeter
Surface Mount Device (SMD) tester
TCX 01
Ergonomic, simple and quick for instant SMD identification.
Types
Quick selection
SMD tester
Voltage
tester
TCX 01
TX 01
Analogue multimeters
MX 1
MX 2B
Resistance measurement
X
Capacitance measurement
X
Diode test
X
Continuity test
X
Phase identification
AC
AC and DC
AC and DC
X
X
X
X
X
X
X
X
VX 0003
VX 0100
X
Current measurement
AC and DC
Current measurement with clamp
AC and DC
MN09 200A
LF electric field measurement (V/m)
LED - analogue display
Digital display
Power supply: battery / type
Pages
X
X
X
X
X
10Hz-3 KHz
10Hz -100KHz
X
X
X
2x1.5v /LR44
1x9V/6F22
9
12
1x 1.5V/LR6
13
n Immediate implementation
n Wide dynamic range for
measurement (6,000 counts for
accurate testing of the highest
and lowest values)
n Test probes protected by a rigid
cap
Field testers
Specifications
Voltage measurement
n Automatic recognition of the SMD
1x9V/6F22
13
10-11
Specifications TCX 01
Display
6,000 counts
Selection of ranges
Automatic or Manual
RangeResolution
Accuracy
600 Ω0.1 Ω
6 kΩ1 Ω
Resistance
60 kΩ10 Ω
±(1.2 % of reading + 2 digits)
600 kΩ100 Ω
6 MΩ
1 kΩ
60 MΩ
10 kΩ
±(2 % of reading + 2 digits)
6 nF
1 pF
±(5.0 % of reading + 5 digits
60 nF
10 pF
600 nF
100 pF
±(3.0 % of reading + 3 digits)
Capacitance6 µF
1 nF
60 µF
10 nF
600 µF
100 nF
±(5.0 % of reading + 5 digits)
6 mF
1 µF
60 mF
10 µFDiode and semiconductor
2V
Itest: ~1 mA / Vtest: ~2.8 V
junction test
Continuity test R < 30 Ω
Automatic shutdown
10 min
Power supply
2 x 1.5 V AG13 / LR44 / 357A
Dimensions / weight
181 x 35 x 20 mm / 65 g
Standard state at delivery:
TCX001-Z: 1 TCX delivered with soft case for storage,
2 x 1.5 V button cells and operating manual
Accessories: Set of 2 x 1.5 V LR44 batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01296036
8
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
9
LF ELECTRIC FIELD Testers
LF ELECTRIC FIELD testers
Technical specifications
V
Hz
VX 0003
Display & Buzzer
Display on 2 scales of 7 LEDs each
VX 0100
•
2,000-count backlit LCD display
VX 0003 & VX 0100
•
Direct display in Volt/m (compatible with standards)
•
•
Buzzer proportional to the field level
•
•
•
•
On / Off (with automatic shutdown after 30 min)
•
•
Measurement Hold
•
•
Buzzer On/Off
•
•
Manual
Automatic
Indication of the measurement frequency range
•
"Low battery" & "Hold" indicators
Measure your exposure to electromagnetic pollution in your home or office.
The VX 0003 and VX 0100 testers are easy-to-use, economical and trustworthy! They are used mainly when testing new or renovated electrical installations and in technical and vocational training.
Commands
Selection of measurement range
Selection of 3 kHz filter (<, >, full band)
•
Antenna & Reference
Built-in "field" antenna
The VX 0003 and VX 0100 BioTest field testers/meters instantaneously
indicate the level of the low-frequency electric field. Ideal for the residential
and tertiary sectors, they can be used by both professionals and DIY
enthusiasts.
•
•
Removable "field" antenna, diameter 62 mm
+ Cable detection function
•
"Individual" field measurement reference
+ continuity rod
•
•
"Earth" field measurement reference
•
•
•
•
Optional accessory
Measurements
RMS electric field intensity in V/m
Sensitivity & Accuracy
n Test of the pollution generated
by electrical power distribution
(0-3 kHz) (VX 0003/VX 0100)
n Test of the pollution generated by
the equipment connected
(3-100 kHz) (VX 0100)
n Audible alarm for immediate
identification of the field levels
2 sensitivity ranges (compatible with standards)
5 to 100 V/m - 100 to 2,000 V/m
1,0 to 200,0 V/m - 200 to 2,000 V/m
Measurement accuracy (in laboratory conditions)
± 10% on LED thresholds
± 3% ± 20 D @ 50/60 Hz
n Testing in accordance with the
current and future standards and
directives
Frequency range
n 2 complementary methods for
more effective measurements
Analysis of electrical distribution, 10 Hz to 3 KHz
Analysis of equipment connected to the mains
•
•
10 Hz to 3 kHz
10 Hz to 3 kHz (3 kHz low-pass filter)
3 kHz to 100 kHz (3 kHz high-pass filter)
10 Hz to 100 kHz (no 3 kHz filter)
General specifications
9 V battery (supplied) – Battery life 60 to 80 hours
Automatic shutdown function (30 min)
Power supply
- Representative method: field
measurement while taking
the individual's presence into
account
Mechanical specifications
IP65 leakproof casing- Dimensions 63.6 x 163 x 40 mm – Weight approx. 200 g with battery
Warranty
2 years
- Traditional method: fields
referenced to earth
n External antenna for field
measurement and cable detection
(VX 0100)
Standard state at delivery
Specific optional accessories
1 VX delivered with earth cable,
socket tester and 9 V battery
1 VX delivered with earth cable, socket tester and 9 V battery
Bag for VX
testers
References to order
10
Example of application
Standards
Low-frequency fields between 10 Hz
and 100 kHz are harmful.
•W
HO / ICNIRP recommendations (World Health Organization / International
Commission on No-Ionizing Radiation Protection)
• IEEE C95.6-2002 (international standard - Public, 0-3 kHz range)
• European Directive 1999/519/CE (Public, 0-100 kHz range and beyond)
•European Directive 2004/40/CE (Workers, 0-100 kHz range and beyond)
• 2010 draft standard, EN IEC 62493 (lighting systems)
• EN50366 standard and IEC 62233 in 2012 (domestic electrical equipment)
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
VX0003: VX0003 field tester delivered with a bag
VX0100: VX0100 field tester delivered in a case
Continuity rod
For the VX 0100:
• Continuity rod . . . . . . . . . . . . . . . . . . . . . . . P01102084
• Continuity rod adapter . . . . . . . P01102034
•H
X0104 bag
For the VX 0003:
• HX0009 case
11
For further details…
voltage Tester ON-SITE ANALOGUE multimeters
V
V
TX 01
With their needle and dial, the MX 1 and MX 2B multimeters are easy to read
and quickly display the measurement results.
An essential tool for electrical testing and diagnostics.
n Electrical continuity testing with
audible and visual indication
n Phase identification
n Autotest function to check the
status of the instrument and the
battery
n Removable test probe with
standard Ø4 mm banana
connection
n Built-in system for stowing the
lead
n Extra-bright LEDs
Specifications
dB
mx 1 & mx 2b
LED voltage tester
n AC and DC voltage testing
A
TX 01
Voltage test
12 V to 690 V (7 diodes)
Audible alarm
U > 50 V
Phase identification
Flashing "Ph" diode for U > 100 V~
Operating frequency
DC … 400 Hz
Audible continuityYes
Resistance
2 kΩ to 300 kΩ (3 diodes)
Power supply
1 x 9 V 6F22
Electrical safety
600 V CAT III
Dimensions / Weight
193 x 47 x 36 mm / 170 g
Built-in 1.2 m lead with Ø2 mm test probe
Other features
+ Ø2 mm removable test probe
n IP65 shockproof and leakproof
casing
n Parallax mirror for precise
measurements
n Audible continuity
n Faulty fuse indicator
n Protection of the ohmmeter
function by an audible alarm
n Measurement up to 200 A
with clamp (MX 2B)
Specifications
MX 1MX 2B
Display
Analogue with parallax mirror / Scale length 80 mm
DC voltage
10 mV to 600 V
0.01 V to 600 V
Calibres
150 mV / 0.5 V / 1.5 V / 5 V / 15 V / 50 V
0.5 V / 1.5 V / 5 V / 15 V / 50 V
150 V / 500 V / 1.5 kV(1)
150 V / 500 V / 1.5 kV(1)
Accuracy class
2
2
AC voltage
10 mV to 600 V
0.01 V to 600 V
5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1)
Calibres
5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1)
Accuracy class
2.5
2.5
DC current2 µA to 10 A
1 µA to 50 µA / 10 A
Calibres
50 µA / 500 µA / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A
50 µA / 10 A
Accuracy class 2
2
AC current20 µA to 10 A
With a 1,000/1 clamp
Calibres
50 µA / 500 µA / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A
10 A / 20 A / 100 A / 200 A
Accuracy class
2.5
3
Resistance
Audible alarm for voltage presence
Calibres
x 1 / x 10 / x 100
Middle point
200 Ω / 2 kΩ / 20 kΩ
Accuracy class
2.5
Audible continuity
< 150 Ω
Other measurements
Diode test
Yes
dB
Yes
Protection rating
IP 65
Power supply
1 x 1.5 V AA or LR6
Electrical safety
600 V CAT III as per IEC / EN 61010-1 Edition 2
Dimensions / Weight
40 x 98 x 150 mm / 420 g
(1) Use limited to 600 Vmax
Specifications
MINI 01
MN 09
Clamping diameter
10 mm
20 mm
Measurement range
2 A to 150 Aac
0,5 A to 200 Aac
Transformation ratio1,000/1 1,000/1
Standard state at delivery
12
TX0001-Z: delivered with a removable test probe, a 9 V battery and an operating
manual
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Standard state at delivery
References to order
MX 1 with 1 set of measurement leads
with test probes, 1 x 1.5 V battery and
user manual in 5 languages
MX 2 with 1 set of measurement leads
with test probes, 1 x 1.5 V battery,
1 current clamp and user manual in
5 languages
MX1: 1 MX 1
MX0001-T: 1 MX 1 delivered with 1 TX1
voltage tester and a hard case.
MX0002B: 1 MX 2B delivered with an
MN09 current clamp
MX0002BT: 1 MX 2B delivered with an
MN01 current clamp, 1 TX1 tester and a
hard case
P01105101Z: 1 MINI01 current clamp
P01120402: 1 MN09 current clamp
TX0001-Z: 1 TX01 LED tester
Available accessories
See pages 96 to 107
Mini 01
MX 2B with MN 09
13
For further details…
ON-SITE MULTIMeters
on-site MULTIMeters
Selection guide
8 multimeter families to meet all your needs:
High-End Graphical
Multimeter/Recorder
for everyone
Digital for Difficult Environments
General-purpose Digital
Benchtop Digital
Electrical
Laboratory
Industry,
Electrical Engineering,
Electronics
Industry
Atex / IECEx
MTX 3292
MTX 3293
MTX 3290
MTX 3291
MTX 57EX
MX 26
MX 24
MX 24B
MTX 202
MTX 203
MX 5006
MX 5060
Graphical colour
Digital
Digital
Digital
Digital
Digital
Digital
Display resolution (counts)
100,000
6,000 or 60,000
50,000
5,000 / 50,000
5,000 / 50,000 (1)
2,000 or 4,000
6,000 or 60,000
TRMS / AVG measurement
TRMS
AC & AC+DC
TRMS
AC & AC+DC
TRMS
AC & AC+DC
TRMS
AC & AC+DC
TRMS
AC & AC+DC
TRMS AC
TRMS AC & AC+DC
4
•
•
•/•
0.02 % to 0.1 %
100 kHz or 200 kHz
•/•
•
IP67
2
•
1
•
1
•
1
•
1
2
•
•/•
0.08%
20 kHz or 100 kHz
•/•
•
IP67
-/•
0.03%
50 kHz
•/•
•/•
0.30%
100 kHz
•/•
•/•
0.30%
1 kHz
•/•
-/•
0.5% or 0.2%
1 kHz
•/•
•/•
0.80%
20 kHz or 100 kHz
•/•
•
1,000 V
20 A (30 s)
•/•
10 MΩ /•/•
5 MHz /•/•
•/•
10 mF
•/•
•/•
250 µs /•
300 Hz
All, ratio integrated
500 kΩ
1,000 V or 600 V
20 A (30 s) (1)
•/•
60 MΩ /•/•
600 kHz /•/•
•/• (1)
60 mF
•/•/• (1)
250 µs /•
300 Hz
V/A ratio
300 kΩ
600 V
500 mA
•/50 MΩ /•/•
500 kHz/-/•
•/•
50 mF
•/•/•
1 ms/-
•/•
•/•/•
•/•/•
6,500
•
•/•/•
•/•
•/•/•
•/•/• (1)
Relative Surv
/•/- (1)
•/•
•/•/•
•/-/-
•/•
•/-/-
•/-/-
600 / 1,000
•
•/•
•
26-27
600 / 1, 000 (2)
•
•/•
- / 600
•/•
•
21
Quick selection
Technology
14
an authentic
Simultaneous display(s)
Fast bargraph
Graph of measurements over time
Backlighting / Automatic power-off
DC basic accuracy
Bandwidth
Auto / Manual ranges
AutoPeak for Crest Factor
Ingress protection
Explosive atmospheres (ATEX)
Available measurements
AC/ DC voltage
AC/ DC current
Single A terminal / Simultaneous U & I
Resistance / audible continuity / diode test
Frequency / period / duty cycle
Pulse width / pulse count
Capacitance
Temperature Pt100-Pt1,000 / TC J-K
dBm / resistive power
U & I peak / crest factor
Filter for digital variable speed drives
Direct measurement with clamp
Low impedance AC voltage measurement
Measurement processing
Display Hold / Auto-Hold functions
Min / Max / Avg monitoring
Relative measurements / dB ratio / %
Memory capacity + measurement graphs
Time/date-stamping (SURV & MEM)
RS232 / USB / Bluetooth interface
Safety & reliability
EN61010 CAT IV / III
Electronic switch
Protected access to batteries / Fuses
"Closed casing" software calibration
Catalogue page
(1) Depending on models. (2) MTX 3291 model only
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
24-25
IP67
•
IP54
750 V / 1,000 V
10 A
750 V / 1,000 V
20 A (30 s) (1)
750 V / 1,000 V
10 A (1)
50 MΩ/•/•
500 kHz/-/-
50 MΩ/•/•
500 kHz/-/-
40 MΩ or 60 MΩ /•/•
50 mF
50 mF
100 mF
-/•
1 ms/•
•
1 kHz BW
•
•
1,000 V or 600 V
20 A (30s)
•/•
60 MΩ /•/•
600 kHz /•/•
•/• (1)
60 mF
•/•/• (1)
250 µs /•
300 Hz
500 kΩ
300 kΩ
•/•
•/•/• (1)
•/-
•/•
•/•/•
•/•/• (1)
Relative Surv
/•/- (1)
- / 600
- / 600
- / 600
600 / 1,000
•/•
•
18-19
•/•
•
18-19
•/•
•
•/•
30-31
16-17
15
BASIC ON-SITE DIGITAL MULTIMeters
V
BASIC ON-SITE DIGITAL MULTIMeters
A
Concept TRMS AC
The METRIX® tools of reference
for applications in the electrical sector
MTX 202 & MTX 203
Specifications
A range of 2 simple, basic TRMS AC multimeters with digital display for
measuring on electrical networks and installations up to 600 V CAT III.
These multimeters are general-purpose professional measuring instruments.
They are the best tools for day-to-day use requiring the TRMS measurements, accuracy, rugged design and reliability of an on-site instrument.
n Automatic TRMS AC
measurements on all the calibres
for most of the customary
electrical signals:
-A
C/DC voltage;
-V
LowZ low-impedance voltage;
- t emperature in °C and °F via K
thermocouple;
- r esistance and audible continuity,
diode threshold voltage test;
-c
apacitance measurement and
AC/DC current measurement
from 1 μA to 10 A (depending on
model) plus manual RANGE
n No-contact voltage (NCV)
indication useful for detecting live
cables at 230 V
n Blue backlighting with torch
for optimized display in dark
environments
n Automatic power-off after
30 minutes without activity which
can be inhibited (permanent
mode) to optimize the 500-hour
battery life and the lifespan of the
batteries
MTX 202MTX 203
Quick selection
Display resolution
4,000 counts
6,000 counts
Automatic power-off
30 min / Permanent mode
Basic accuracy (Vdc)0.2 %
Bandwidth
1 KHz
Available measurements
AC/DC voltage (ranges)
400 mV to 600 V / 600 V
600 mV to 750 V / 1,000 V
AC/DC current (ranges)
20 mA to 10 A
10 µA to 10 A
Resistance (ranges)1 Ω to 40 MΩ1 Ω to 60 MΩ
Audible continuityYes
Diode testYes
Capacitance (ranges) 1 nF to 100 mF
NCV
230 V / 50 Hz
Temperature
-55 °C to 1,200 °C
Measurement processing
Other measurements
HOLD mode
General specifications
Power supply / Battery life
2 x 1.5 V batteries / 500 h
Dimensions / Weight
170 x 80 x 50 mm / 320 g
Safety and reliability
Electrical safety
EN61010-02-33 - 600 V CAT III
High-resistance casing
IP 54
Warranty
2 years
n Easy access to the 2 x 1.5 V
batteries and fuse(s) by loosening
2 screws on the rear
n Compliant with the latest
IEC61010-2-033 – 600 V CAT III
safety standards
n A compact casing with a multipurpose sheath which fits in
one hand: stowing of the leads,
magnetized for mounting on
metal cabinets and shockproof
protection with the MULTIFIX
system
Standard state at delivery
Specific or adapted accessories
1 multimeter with batteries and fuses
installed, 1 elastomer sheath with
stand, 1 set of 2 safety leads, 1 wire K
thermocouple, user manual
K thermocouple
Multifix mounting
accessory
References to order
SHT 40kV probe
Available accessories
MTX 202 & MTX 203
Multimètres numériques TRMS AC,
jusqu’à 6 000 points
See pages 96 to 107
MTX202-Z: MTX202 delivered in blister pack
MTX203-Z: MTX203 delivered in blister pack
16
Ergonomiques et
multi-usages les
multimètres B-ASYC
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
e
Des mesures TRMS AC en courant et
tension et tous les calibres programmés
en automatique pour plus de simplicité
e
Indication de tension sans contact NCV
pour des interventions sans contact en
toute sécurité
e
Utiles, un écran rétro-éclairé et une lampe
torche intégrée
e
e
For further details…
Ergonomique : ils se tiennent dans la main
Pratique : grâce à sa gaine anti-choc avec rangement pour cordons,
et aimantée, pour fixation sur armoire métallique
IEC 61010-2-033
600 V CAT III
IP
54
17
ON-SITE DIGITAL MULTIMeters
V
ON-SITE DIGITAL MULTIMeters
A
Hz
TRMS AC & TRMS AC+DC Concept
Mx 24, MX 24B & MX 26
TRMS measurements for accurate results whatever the waveform.
n Bandwidth up to 100 kHz
n Elastomer protective sheath
n A VLowZ low-impedance function to
avoid stray voltages
n Unique system for easy access to
the batteries and fuses with extra
safety
n Innovative design with a compact,
rugged casing
n Large display with bargraph and
backlighting for easy reading
Specifications
MX 24
MX 24B
Quick selection
Display5,000/50,000 counts + bargraph
Backlighting/auto-shutdown
Yes / Yes
TRMS measurements
TRMS AC+DC
Basic accuracy for DC voltage
0.3 %
Bandwidth
1 kHz
Available measurements
AC/DC voltage (ranges) 500 mV to 750 Vac / 1,000 Vdc
AC/DC current (ranges)
50 mA - 20 A
500 mA - 20 A
Resistance/audible continuity500 Ω to 50 MΩ / Yes
Frequency 5 Hz to 500kHz
Capacitance / diode test
50 nF to 50mF / Yes
Measurement processing
Min/Max/Avg monitoring
Yes / Yes / No
PC communication / backup
No
Safety and reliability
Electrical safety
EN61010-1, 2001 - 600 V CAT III
Warranty
3 years
MX 26
TRMS AC & AC+DC
100 kHz
500 mA - 10 A
Yes / Yes / Yes
Optical serial link
& software
Standard state at delivery
References to order
1 MX: 1 elastomer sheath, 1 set of 2 safety leads,
1 x 9 V battery installed
MX0024-CG: MX 24
MX0024-CL: MX 24 delivered in hard case
MX0024B-CZ: MX 24B in blister pack
MX0024B-CL: MX 24B delivered in hard case
MX0026-G: MX 26
MX0026-T: MX 26 with communication kit delivered in hard case
Recyclable and recoverable,
in compliance with the DEEE2002/96/CE directive
Available accessories
See pages 96 to 107
18
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
19
For further details…
MULTIMeters FOR DIFFICULT ENVIRONMENTS
V
A
MULTIMeters FOR DIFFICULT ENVIRONMENTS
Hz
ASYC II multimeter
A unique tool for all your measurements usable
in explosive and non-explosive environments
MX 57Ex
This ATEX-certified 50,000-count TRMS digital multimeter is designed
for use in hazardous environments.
Use in explosive gas and dust
atmospheres in the following
conditions:
n Mines: category I M2
n Surface industries: category 2
(gas and dust) I I 2GD
- Zones 1 & 2 (gas) Ex ib I and Ex
ib IIC T5 or T4 or T3
- and zones 21 & 22 (dust)
Ex ibD21 IP6X T°… °C
The MX 57Ex is a comprehensive
instrument which complies with
the applicable standards and
regulations.
It is certified LCIE 02 ATEX 6005
X and, according to the "old
regulations", EEx ib IIC T5 / EEx ib I
according to:
n CE inspection certificate of type
number LCIE 02 ATEX 6005 X
and amendments LCIE 02 ATEX
6005X / 01, 02, 03
It is equipped with a 500 mA fuse.
It is supplied in a bag with some of
its accessories.
It also complies with the
stipulations of the European
directives:
n Low Voltage 2006/95/CE
n Electromagnetic Compatibility
EMC 89/336/CE et 93/68/CE
ATEX 94/9/CE directive
EN/IEC 60079-0 – EN/IEC 60079-11
EN/IEC 61241-11 – EN/IEC 61241-0
EN/IEC 61010-1 – 600 V CAT III
Specifications MX 57EX
Display 50,000 counts
Bargraph
Analogue, 34 segments, 20 meas./s
DC, AC & AC+DC voltage
Ranges 5 calibres from 500 mV to 600 V
Vdc accuracy
0.025 %
Vac accuracy
0.3 %
Bandwidth 50 kHz
DC, AC & AC+DC current
Ranges500 μA, 5 mA, 50 mA & 500 mA
Adc accuracy 0.2 %
Aac accuracy
0.6 %
Bandwidth 5 kHz
Frequency
Ranges
0.62 Hz to 500 kHz - Accuracy 0.03%
Other measurements
Resistance
6 ranges from 500 Ω to 50 MΩ
Audible continuity
Detection threshold from 10 Ω to 20 Ω - response time 1 ms
Diode test 0 to 2 V
Capacitance
7 ranges from 50 nF to 50 mF
Temperature
-200 °C to +800 °C
Pt100 or Pt1,000 platinum probes
Duty cycle – dB function
Other features
and U2/R resistive power
Pulse width – timer – event counting
General specifications
Battery life 1 certified 9 V battery / 300 hrs
Dimensions / Weight
189 x 82 x 40 mm / 400 g (without sheath/stand)
Safety and reliability
ATEX 94/9/CE directive
EN/IEC 60079-0 – EN/IEC 60079-11
EN/IEC 61241-11 – EN/IEC 61241-0
Safety
EN/IEC 61010-1 – 600 V CAT III
CE inspection certificate type number
LCIE 02 ATEX 6005 X and amendments
LCIE 02 ATEX 6005X / 01, 02, 03
High-resistance casing IP 67
Warranty
3 years
Standard state at delivery
Reference to order
1 multimeter with battery and fuse(s)
installed, 1 elastomer sheath with stand,
1 set of 2 PVC safety leads and 1 user
manual
MX0057CX: MX 57 delivered in a specific
soft case
MX 20HD – MX 44HD
MX 57EX – MX 58HD – MX 59HD
Multimètres numériques de terrain
Available accessories
adaptés aux environnements difficiles
See pages 96 to 107
20
21
Une gamme de
multimètres durcis
adaptée aux exigences
les plus difficiles !
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
For further details…
MX 57Ex,
le multimètre
certifié ATEX
ASYC IV FAMILY OF DIGITAL MULTIMeters
ASYC IV FAMILY OF DIGITAL MULTIMeters
IP 67
MAX/MIN
AVG/PEAK
is revolutionizing multimeters
with the ASYC IV
Multimeters with colour graphical screens for the lab or the field:
the reference for multimeters.
n IP67 leakproof multimeters
n Graphical display of the trends and multiple parameters
n Bandwidth: 200 kHz
n Basic accuracy: 0.02 %
n Multiple analytical tools:
- Time/date-stamped monitoring of MIN/MAX/AVG and PEAK
- Direct current measurement with integration of the report
... Plus unrivalled simplicity of use, as always!
n Directly accessible, the various
measurements are represented
explicitly by pictograms on the
electronic switch
n The display allows users either
to view the measurement results
as numerical values, on 2 display
levels, or as graphs showing the
trend over time
models
is revolutionizing multimeters with the colour graphical ASYC IV
The ASYC IV multimeters are ideal for many
applications in industry, telecommunications and
Defence.
Their multiple functions make them easy to use for
electrical, electronic or machine maintenance.
In electronics, the ASYC IV models can be used to
test cabling, computing or medical equipment or
SMDs.
In industry, they are suitable for the applications
encountered in departments dealing with the
automated systems and processes in highly varied
sectors: food, plastics, concrete, metal, paper, wood,
oil and nuclear.
The ASYC IV models can be used for maintenance
of many industrial machines: numerical control,
motors, generators, etc.
These versatile instruments are ideal for the needs
of expert electrical installers and professionals in
the transport and energy sectors.
High-performance, accessible and ergonomic, the
ASYC IV models can also be used in training and
research.
This recorder-multimeter offers:
Colour 320 x 240-pixel liquid-crystal matrix
screen with black background for easier reading
n Graphical display of the trends on an overview
screen
n Trace, cursors and zoom on recordings
n Recording of 10 sequences
Dynamic recorders...
n Up to 6,500 measurements stored in memory
n The four ASYC IV models
Models
MTX 3290 MTX 3291MTX 3292 MTX 3293
Type of display
DigitalDigital
monochrome monochrome Colour graphical
70 x 52 mm
backlit
70 x 52 mm
70 x 52 mm
Type of display
7 function keys + setup
Counts
6,00060,000
Data storage 1,000 mesures 6,500 mesures
Power supply
4 x R6 batteries or 4 rechargeable batteries
Communication
IR / USB
IR / USB (Bluetooth option)
22
n Simplified definition of the number of measurements, the interval,
the duration and the memory capacity
n Internal storage of the 10 measurement sequences
n Interactive zoom function on the recordings
n A simple monitoring mode displaying the time/date-stamped
MIN/MAX and AVG values
23
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
ASYC IV FAMILY OF DIGITAL MULTIMeters
ASYC IV FAMILY OF DIGITAL MULTIMeters
Technical specifications
V
A
Hz
MTX 3291
Length of scale
Range
Resolution
60 mV
600 mV
6V
60 V
600 V
1,000 V
0.001 mV
0.01 mV
0.0001 V
0.001 V
0.01 V
0.1 V
DC accuracy
0.05 %
0.3 %
AC and AC+DC bandwidth
100 kHz
20 kHz
AC and AC+DC basic accuracy
MTX 3290 & MTX 3291
MTX 3290
0.5 %
0.8 %
VLowZ AC
300 kΩ
DC, AC and AC+DC current
The METRIX® designed for the field: a single, comprehensive, high-performance
diagnostic instrument which nevertheless remains particularly easy to use!
Range
600 µA
6 mA
60 mA
Resolution
0.01 µA
0.1 µA
0.001 mA
DC accuracy
600 mA
6A
0.01 mA
0.1 A
10 A / 20 A
(30 s max)
0.1 A
0.08 %
AC and AC+DC bandwidth
20 kHz
20 kHz
1%
1.5 %
AC and AC+DC basic accuracy
Frequency
n An innovative design with
ergonomics suited to work
in the field: fingertip function
selection on the numeric keypad
and comfortable grip, a large
backlit LCD screen (3 positions)
for viewing 2 simultaneous
measurements (segments 14 mm
high)
n CLAMP function for direct
measurement of the current by
integrating the transformation
ratio: 1/1, 1/10, 1/100 and
1/1,000 mV/A
Frequency range
Basic accuracy
n Unrivalled user-friendliness:
- "Virtual" one key / one function
- Automatic V/A selection by cable
positions and 8 backlit function
keys
n Secondary measurements for
electronics: DBm, resistive power,
counting, pulse width, gain
measurement, resistive power
n Communication for MTX 3291:
isolated USB; "real-time" data
transfer onto PC, drivers and SCPI
commands
n Up to 2 x 60,000-count digital
displays + bargraph: central zero,
Vdc and Idc
Resolution
600 Hz
0.01 Hz
60 kHz
1 Hz
600 kHz
10 Hz
100 Hz
Resistance and continuity
Ranges
Resolution
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ
0.1 Ω
1Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
0.2 %
0.5 %
Protection
Electronic protection
Audible continuity detection
600 Ω SIGNAL < 30 Ω +/- 5 Ω < 5 V
Diode test
Voltage measurement
3 V - resolution 1 mV
Capacitance
Ranges
Resolution
6 nF
60 nF
600 nF
0.001 nF 0.01 nF
0.1 nF
6 µF
60 µF
600 µF
6 mF
60 mF
0.001 µF0.01 µF0.1 µF1 µF10 µF
Temperature Pt100/1,000
-200 °C to +800 °C
Accuracy
0.1 %
Other functions
MAX / MIN / AVG or PEAK +/ΔREL
PWM filter
n Reminder of the measurement
connections for each function
Clamp function V output with direct reading
Secondary functions
n Extra-versatile: V, A, Ohms, Hz,
diode, capacitance, dB, °C, etc.
Low-impedance measurement,
time/date-stamped MIN, MAX and
AVG monitoring, etc.
On all the main positions measured
REL relative value + secondary display with measured reference value
300 Hz 4th-order low-pass filter for measurements on variable speed drives of asynchronous motors
Integration of ratio : 1/1, 1/10, 1/100, 1/1,000 mV/A
dBm and resistive power in VA, +/- duty cycle and pulse width
Central zero
Selectable or automatic for Vdc and Idc
USB communication
With SX-DMM - SCPI commands
General specifications
Type of display
PC interfaces
Transflective LCD with backlighting and digits 14 mm high
Double 60,000-count or 6,000-count display
USB optical socket - SX-DMM software
Power supply
4 x AA batteries (or Ni-MH rechargeable batteries)
Safety / EMC
Safety as per IEC61010-1 (2001) 1,000 V CAT III or 600 V CAT III – EMC as per EN61326-1
Environment
Mechanical specifications
Storage: -20 °C to +70 °C – Operation: -10 °C to +50 °C
Dimensions (L x W x H): 196 x 90 x 47.1 mm / Weight: 570 g
Warranty
Multimeters with fingertip control
Each main measurement is instantaneously
accessible with one of the 6 dedicated keys, without
having to choose between the 4 or 5 positions of
a mechanical switch for a simple voltage or current
measurement.
24
Detailed product brochures can be downloaded free of charge from www.metrix.fr
6 kHz
0.1 Hz
Operating range
n 3 connection terminals, so a single
fuse from 1 μA to 10 A
Unique on the market, the electronic switch replaces
the traditional mechanical switch, which is the major
source of faults on handheld multimeters, while also
improving performance and safety. At the same
time, the possibility of direct access using the
keypad avoids the intermediate positions typical of
mechanical switches.
60 Hz
www.metrix.fr
3 years
Standard state at delivery
Specific accessories
References to order
Multimeter delivered with 4 x 1.5 V
alkaline batteries, red straight/
straight lead 1.5 m long, black straight/
straight lead 1.5 m long, red CAT IV
1 kV test probe, black CAT IV 1 kV
test probe, user manual on CD and
startup guide on paper, USB cable
and remote programming manual for
communicating version
HX0056-Z: optical/USB cable
MTX328X and MTX329X
HX0053: external NI-MH battery charger
for MTX328X et MTX329X
HX0052B: transport kit for MTX329X
6,000 and 60,000 counts
MTX3290: DMM 6 kcts TRMS 20 kHz
MTX3291: DMM 60 kcts TRMS 100 kHz USB
Available
accessories
See pages 96 to 107
For further details…
25
ASYC IV GRAPHICAL FAMILY DIGITAL MULTIMeters
V
A
ASYC IV GRAPHICAL FAMILY DIGITAL MULTIMeters
Hz
Technical specifications
MTX 3292
Length of scale
Range
100 mV*
Resolution
ASYC IV, the new tools from Metrix
2 portable multimeters with colour graphical display for direct measurement of the main electrical quantities: innovative design, compact, rugged,
leakproof and easy to grip for all your measurements.
n Colour 320 x 240-pixel liquid-crystal
matrix screen with black background
for easier reading
n K/J thermocouple or Pt temperature
measurement from -200 °C to
+1,200 °C
n Multi-parameter display:
1 main and 4 secondary measurements
n Current measurement using clamp
with direct reading (integration of
ratio)
n 4 x 100,000-count display and TRMS
AC+DC converter
n 1,000 V CAT III protection
n Bandwidth: 100 kHz to 200 kHz
n Voltage measurement up to 1,000 V
n Current measurement up to 10 A
(20 A for 30 s)
n Resistance measurement up to 50 MΩ
n Capacitance measurement up to 10 mF
n Frequency measurement up to 5 MHz
n Numerous additional measurement
functions: low-pass PWM filter
(variable speed drive), and VLowZ low
impedance measurement (500 k),
dB/dBm measurement, duty cycle,
pulses, diode measurements:
Zener or LED, etc.
n A "reference" multimeter with
its 100 kcounts and display of its
specifications associated with a
RELative mode
High-performance graphical multimeters…
n Graphical display of the trends on an
overview screen
n Recall of traces, cursors and zoom on
recordings
n Interactive zoom function on the
recordings
n Simplified definition of the number
of measurements, the interval (1 s to
24 h), the duration and the memory
capacity
n In addition, a simple monitoring mode
displaying the time/date-stamped
Min / Max and Avg values
n Internal storage of 10 measurement
sequences
…And much more!
n Contextual reminder of connections
n Classic USB communication or
Bluetooth available as an option;
the SX-DMM software can be used
for real-time processing of the data
on a PC, instrument upgrades and
instrument calibration, with new
functions: automatic time adjustment
and display of available memory
capacity
26
n IP67 ingress protection: waterproof
and dustproof, ideal for outdoor
conditions
n Battery life of up to 100 hours with
management of the level
n No time wasted: the instrument
operates while it is charging
n Developed and manufactured in
France
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
100 V
1 mV
1,000 V
10 mV
0.03 %
0.02 %
200 kHz
AC and AC+DC basic accuracy
0.3 %
0.3 %
VLowZ AC
500 kΩ
DC. AC and AC+DC current
Range
1,000 µA
10 mA
100 mA
10 nA
0.1 µA
1 µA
1,000 mA
10 A
10 A / 20 A
(30 s max)
10 µA
100 µA
1,000 µA
DC accuracy
0.01 %
AC and AC+DC bandwidth
50 kHz
AC and AC+DC basic accuracy
0.3 %
Frequency
Frequency range
Resolution
10 Hz
100 Hz
0.0001 Hz
1 kHz
10 kHz
0.001 Hz
0.01 Hz
100 kHz
0.1 Hz
1 MHz
1 Hz
5 MHz
10 Hz
100 Hz
Resistance and continuity
Ranges
100 Ω*
1 kΩ
100 kΩ
1,000 kΩ
10 MΩ
50 MΩ
Resolution
0.001 Ω
10 mΩ
100 kΩ
10 Ω
10 Ω
1 kΩ
Basic accuracy
0.07 %
Protection
1,000 V electronic protection
Audible continuity detection
1,000 Ω calibre: SIGNAL <20 Ω < 3.5 V
Diode test
Voltage measurement
2.6 V diode < 1 mA + 0-20 V Zener diode or LED < 11 mA
Capacitance
Ranges
Resolution
1 nF
1 pF
10 nF
100 nF
10 pF
0.1 nF
1,000 nF
1 nF
10 µF
0.01 µF
100 µF
0.1 µF
1 mF
1 µF
10 mF
10 µF
Temperature Pt100/1,000
Operating range
-200 °C to +800 °C with Pt and -40 °C to +1,200 °C with K thermocouple
Accuracy
0.1 %
Other measurement functions
SURV MAX / MIN / AVG
REL
On all the main positions measured
REF relative value - delta unit or on 3 displays + main measurement
300 Hz 4th-order low-pass filter for measurements on variable speed drives of asynchronous motors
Display of measurement tolerance + Smin + Smax
GRAPH
Trend of main measurement < 60 s
Secondary measurements
Measurement storage
3 measurements + main measurement
1,000
6,500
General specifications
Type of display
Colour graphical display (70 x 52) with backlighting and black background on 4 x 100,000-count displays
PC interfaces
USB optical connector or Bluetooth - SX-DMM software
Power supply
Charger or 4 x AA batteries (or Ni-MH rechargeable batteries)
Safety / EMC
Safety as per IEC61010-1 (2001) 1,000 V CAT III – EMC as per EN61326-1
Environment
n Rechargeable Ni-MH AA battery with
low self-discharge, the best solution
in terms of quality and price: 4-level
indication of battery capacity + %
10 V
0.1 mV
100 kHz
SPEC
n Up to 6,500 measurements stored in
memory
10 µV
AC and AC+DC bandwidth
PWM filter
Dynamic loggers for capturing faults...
1,000 mV
1 µV
DC accuracy
Resolution
High-level multimeters…
MTX 3293
Mechanical specifications
Warranty
Storage: -20 °C to +70 °C – Operation: -10 °C to +40 °C
Dimensions (L x W x H): 196 x 90 x 47.1 mm / Weight: 570 g
3 years
* Manual access
Standard state at delivery
References to order
Multimeter delivered in screen-printed
box with 4 x NI-MH 2400 mAH 1.5 V
rechargeable batteries, red straight/
straight lead 1.5 m long, black straight/
straight lead 1.5 m long, red CAT IV
1 kV test probe, black CAT IV 1 kV
test probe, USB optical cable + SX-DMM
software, user manual on CD and startup
guide on paper
MTX3292: DMM graph TRMS 100 Kcts Colour 100 kHz USB
MTX3292-BT: DMM graph TRMS 100 Kcts Colour 100 kHz BLUETOOTH
MTX3293: DMM graph TRMS 100 Kcts Colour 200 kHz USB
MTX3293-BT: DMM graph TRMS 100 Kcts Colour 200 kHz BLUETOOTH
Available accessories
See pages 96 to 107
27
For further details…
ACCESSORIES for multimeters
ACCESSORIES for multimeters
Selection guide
Clamps for digital
multimeters
To avoid powering down the circuit, you are advised to measure the current
with a current clamp with A or V output. The direct measurement function
is implemented on the ASYC multimeters (Ax function).
As the clamp function integrates a precise ratio xxxx.XA/xxxx.XV or XA, it
is possible to connect a wide range of current clamps which you can find in
the CHAUVIN ARNOUX Catalogue and on pages 96 to 101 of this document;
however, you should check the input/output range of the clamp to ensure
that it is compatible with the calibres offered by the multimeter.
On the ASYC IV MULTIMETERS, the CLAMP function integrates the
transformation ratio in mV or mA/A according to the coupling selected. The
measurement range of clamp will be adapted to match the measurement
range of the multimeter.
MTX3290 and MTX3291 fixed ratios: 1/1-1/10-1/100-1/1,000 mV/A
List of the main clamps in our CHAUVIN ARNOUX range:
MA100 (miniFLEX)
The accuracy of this "clamp" function depends on the accuracy of the clamp
and of the calibre or range used on the multimeter.
MN 08
K2
AMP 100
Mini 03
MINI02 MINI03
MINI04
General purpose
AC current
MINI05
MINI06
PAC 20
MN 09
Mini 09
General purpose
Products
PAC 11
Mini 05
Mini 02
MINI07
MINI08 MINI09
Products
MINI02 MINI05 MN08/09 AC current
MN89 C106/C107 MiniFLEX MiniFLEX AmpFLEX™
References
P01105102Z P01105105Z P01120401/02 P01120415 P01120304/05 P01120560
P01120561 P01120504
Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges
MX24 2.5 A to 50 A
25 mA to 100 A 2.5 A to 50 A
25 A to 1,200 A 0.5 A to 300 A 0.5 A to 3,000 A 0.5 A to 2,000 A
MX24B / MX26 25 A to 100 A 12 A to 240 A
Clamp performance
Bandwidth 10 kHz 500 Hz 10 kHz 10 kHz 10 kHz 20 kHz 20 kHz 20 kHz
Typical accuracy
1 %
3%-2%
1 %
2 %
0.50 %
1 %
1 %
1%
Clamping diam.
12 mm 12 mm 20 mm 20 mm 52 mm
54 mm 80 mm 140 mm
Output
Direct readings Yes Yes Yes Yes Yes No YesYes
1 mA/A
1 mV/mA – 1 mV/A
1 mA/A
100 mV/A
1 mV/A
100 mV/A – 10 mV/A 10 mV/A – 1 mV/A 10 mV/A – 1 mV/A
Connection
Lead
Lead
Sockets/lead
Lead
Sockets/lead
Casing, 19 mm spacing
References
P01105102Z P01105105Z P01120401/02 P01120415 P01120304/05 P01120560
P01120561 P01120504
Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges
MTX 3290 / MTX 3291
200 mA to 100 A 6 mA to 100 A
0.6 to 240 A
0.6 A to 240 A 6 A to 1,200 A 0.5 A to 300 A 0.5 A to 3,000 A 0.5 A to 2,000 A
MTX 3292 / MTX 3293
50 mA to 100 A 5 mA to 100 A 0.5 to 240 A
0.5 A to 240 A
1 A to 1,200 A
0.5 A to 300 A 0.5 A to 3,000 A 0.5 A to 2,000 A Clamp performance
Bandwidth 10 kHz 500 Hz 10 kHz 10 kHz 10 kHz 20 kHz 20 kHz 20 kHz
Typical accuracy
1 %
3%-2%
1 %
2 %
0.50 %
1 %
1 %
1%
Clamping diam.
12 mm 12 mm 20 mm 20 mm 52 mm
54 mm 80 mm 140 mm
Output
Direct readings Yes Yes Yes Yes Yes No YesYes
1 mA/A
1 mV/mA – 1 mV/A
1 mA/A
100 mV/A
1 mV/A
100 mV/A – 10 mV/A 10 mV/A – 1 mV/A 10 mV/A – 1 mV/A
Connection
Lead
Lead
Sockets/lead
Lead
Sockets/lead
Casing, 19 mm spacing
Products
Products
Current
General purpose
AC & DC current Leakage current
Process
transformer
E6N PAC11PAC20MN73 K2 MN71
References
P01120040A P01120068
P01120071
P01120421 P01120074AP01120420
Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges
0.4 A to 600 Adc MX24 / MX24B / MX26 25 A to 1,400 Adc 25 mA to 240 Aac 2.5 mA to 450 mAdc
25 mA – 80 Aac/dc
250 mA to 12 A
0.2 A to 400 Aac 25 A to 1,000 Aac 25 mA to 240 Aac 2.5 mA to 300 mArms Clamp performance
Bandwidth 2 kHz or 8 kHz 10 kHz
5 kHz
10 kHz 1.5 kHz 10 kHz
Typical accuracy
2 % or 4 %
1.5 % - 2 %
2 %
1 % - 2 %
1 %
1%
Clamping diam.
11.8 mm 39 mm 39 mm 20 mm 3.9 mm 20 mm
Output
Direct readings
Yes YesYesYes
No
No
1 V/A – 10 mV/A 10 mV/A - 1 mV/A
1 mV/A
1 V/A - 10 mV/A
10 mV/A
100 mV/A
Connection Lead Lead Lead Lead Lead Lead
28
Current
General purpose
AC & DC current Leakage current
Process
transformer
E6N PAC11PAC20MN73 K2 MN71
References
P01120040A P01120068
P01120071
P01120421 P01120074AP01120420
Useful measurement range with the multimeter for use from 5 % to 100 % of the multimeter ranges
MTX 3290 / MTX 3291 6 mA to 80 A
60 mA to 600 A
6 A to 1,400 Adc
60 mA to 240 A
6 mA to 450 mAdc
60 mA to 12 A
6 mA to 3.3 Aac
1,000 Aac
MTX 3292 / MTX 3293 5 mA to 80 A
10 mA to 600 Adc
1 A to 1,400 Adc
10 mA to 240 A
1 mA to 450 mAdc
10 mA to 12 A
1 A to 400 Aac
1 A to 1,000 Aac
1 mA to 300 mAac
Clamp performance
Bandwidth 2 kHz or 8 kHz 10 kHz
5 kHz
10 kHz 1.5 kHz 10 kHz
Typical accuracy
2 % or 4 %
1.5 % - 2 %
2 %
1 % - 2 %
1 %
1%
Clamping diam.
11.8 mm 39 mm 39 mm 20 mm 3.9 mm 20 mm
Output
Direct readings
Yes YesYesYes
No
No
1 V/A – 10 mV/A 10 mV/A - 1 mV/A
1 mV/A
1 V/A - 10 mV/A
10 mV/A
100 mV/A
Connection Lead Lead Lead Lead Lead Lead
29
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
LABORATORY MULTIMeters
V
LABORATORY MULTIMeters
A
MX 5006 & Mx 5060
METRIX benchtop multimeters:
laboratory instrumentation reinvented
A tried and tested casing
Simple and effective.
Top performance
n A compact, lightweight casing
0.05 % accuracy and AC, DC or AC+DC TRMS
measurements, as required, as well as AUTO or
manual ranges to optimize your measurements.
Extended functions
MX5006
Lightweight and compact
Multidirectional handle for positioning as you wish.
A casing which is can be stacked on your lab
bench to save space.
The mains lead can be wound round the "feet" for
easy storage.
A display (890 x 450 mm)
Optimized over the whole height of the casing to
offer comfortable reading with 16 mm digits on the
main display above a second simultaneous display.
The transflective LCD screen with backlighting
provides a wider viewing angle making it visible
whatever the conditions.
A double 60,000-count display plus an analogue
view by means of a bargraph.
Equipped with all the traditional functions (voltage,
current, resistance, continuity, diode test), these
multimeters also offer extended functions:
measurement of capacitance, frequency, period
and ΔREL relative. Values expressed as values and
in %.
Measurements in total safety for electrical
engineering applications with 1,000 V CAT III
protection: a VLowZ low input impedance mode for
stable measurements by eliminating "stray" voltages
plus a PWM filter selectable for your measurements
on variable speed drives (asynchronous motors).
Monitoring of your measurements with MIN /
MAX (100 ms) / PEAK (1 ms) recordings to capture
any faults.
The 3 terminals limit handling errors with complete
current autoranging from 50 μ to 20 A. The
MX 5060 is equipped with a USB interface for
remote programming and processing of the data
by our SX-DMM software for multimeters.
A simple, precise mechanical switch for selecting
the main quantity and a secondary function key
marked in colour.
n A particularly easy-to-read
display with widened viewing
angle and digits 16 mm high
Specifications
n Current measurement with a
single current terminal up to 10 A
n MX5060: USB communication
and programming with the SCPI
protocol
MX 5006MX 5060
Resolution
6,000 counts
60,000 counts
Display
Transflective LCD
Backlighting
Widened viewing angle
DC. AC and AC+DC TRMS voltage
Ranges
600 mV to 1,000 V
60 mV to 1,000 V
DC basic accuracy
0.09 %
0.05 %
Useful bandwidth
100 kHz
DC, AC and AC+DC current
Ranges6,000 µA to 10 A (20 A 30 s)
AC and AC+DC basic accuracy 1%
DC basic accuracy
0.80 %
Frequency measurements
Ranges
60 HZ to 60 kHz
Other measurementsPeriod
PWM filter
Resistance and continuity
Ranges600 Ω to 60 MΩ
Basic accuracy
0.40 %
0.20 %
Audible continuity test600 Ω range - threshold < 30 Ω
Diode test
0 to 3 V
Capacitance
6 nF to 60 mF
Temperature with K thermocouple
-200 to +1,200 °C
CommunicationUSB
Other measurementsSURV (MIN/MAX) and Peak +/- / ∆REL
Additional functions
HOLD and AUTO
300 Hz filter
IEC61010-1 safety1,000 V CAT III
Dimensions (H x L x W) / Weight295 x 270 x 95 mm / 1.85 kg
Warranty
3 years
Standard state at delivery
References to order
1 MX: 1 mains power cable, 1 set of
2 measurement leads, 1 user manual
MX5006: 6,000-count benchtop TRMS
multimeter
MX5060: 60,000-count benchtop TRMS
USB multimeter
MX5060
Available accessories
See pages 96 to 107
30
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
31
For further details…
ACCESSORIES for multimeters
ACCESSORIES for multimeters
Software
Metrology software
SX-DMM
SX-ASYC2C/B
MX 57EX-CAL & HX 0059
PC data acquisition software for multimeters
The various versions of this software help you to perform periodic testing
and/or calibration of your instruments with the "casing closed" via their RS
or USB serial communication interface (depending on the model), simply
and effectively.
This data acquisition software can be used to link up to 4 controllable
multimeters, whether they are on-site or benchtop models.
List of controllable multimeters
Without needing to research the technical details of the instrument, users
can execute "manufacturer" procedures or develop their own procedures,
in compliance with the Quality monitoring standards, while ensuring in
particular the reverse traceability of their processes, saving their data and
printing out reports.
n MX 26, MX 53, MX 54, MX 56, MX 57, MX 58, MX 59
n MX 554, MX 556, MX 5060
n MTX 3250
n MTX 3281, MTX 3282, MTX 3283
n MTX 3291, MTX 3292, MTX 3293
List of multimeters supported and associated software
n MX53, MX54, MX55, MX56, MX58, MX59 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SX-ASYC2C/B
This software can be used to communicate with our
multimeters via an RS232, USB or BLUETOOTH link,
depending on the model: This software can be used to
communicate with our multimeters via an RS232, USB
or BLUETOOTH link, depending on the model:
SX-DMM, the software for acquiring, recording and processing the measurements from 1 to 4 multimeters simultaneously. Each channel must be assigned to a COM or
USB serial port for connection to be possible. Several SXDMM sessions can be opened at the same time on a PC.
n MX57
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MX57EX-CAL
n MTX328X and MTX3292 et MTX3293 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HX0059
n MTX3291 and MX5060 (after opening the casing)
offer a calibration kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01196770
The trigger mode and
acquisition intervals
can be set from 100 ms
u pwa rd s a n d t h e
clock can be managed
a u t o m a t i c a l l y,
depending on the
model.
Creation/modification of procedures
Regulatory and connection information
Execution of the procedure and instructions
for the operator
Saving and/or printing of reports
The Math functions:
XY, differential,
integral, curve
smoothing
32
ata export into EXCEL
D
for processing in a
spreadsheet
This software transforms your multimeter(s) into a
power monitor with up to 4 channels for point testing
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
33
ACCESSORIES for multimeters
pocket multimeter clamps
Communication accessories
and software
Description
Selection guide
References
to order
Multimeters
MX 58HD, MX 59HD
MX 58HD, MX 59HD
MX 57Ex
MX 26
MTX 3281, MTX 3282, MTX 3283
MX 55, MX 556
MX 5060
MTX 3292, MTX 3293
MTX 3291, MX 5060
All models Serial link kit for ASYC2 HD version
Acquisition software for ASYC2
ASYC2 family calibration software
MX 57Ex calibration software
MX26 software kit
RS232 optical cable
MTX 328X V1.0 calibration software
Optical / USB cable
Bluetooth / USB adapter for PC
Communication kit with software
Calibration software for MX 553 & MX 556
Software for MX 553 & MX 556
USB A-USB B cable
ASYC4 100K calibration software
"Open casing" calibration kit
USB/RS232 adapter for PC SX-ASYC2HD
SX-DMM2
SX-ASYC2C/B
MX57EX-CAL
SX-DMMK2
HX2002
HX0059
HX0056-Z
P01637301
HX0050
SX-ASYC2C/B
SX-DMMBT/B
P01295293
HX0059B
P01196770
HX0055
Specifications
AC current
n Instrument drivers for LabView and LabWindows CVI
The multimeters are available in the Support section of our website,
as are the USB drivers of our accessories: HX0055 and HX0056
MX 355
MX 650
MX 655
MX 670
MX 675
•
•
•
•
•
•
•
•
DC current
•
Clamping ø 26 mm
•
•
Clamping ø 36 mm
•
Clamping ø 40 mm
•
Clamping ø 42 mm
•
•
•
•
2
2
Backlighting
•
•
1,000 A
1,000 A
Bargraph
AC current
•
400 A
DC current
•
•
400 A
1,000 A
400 A
•
1,000 A
1,000 A
600 V
600 V
750 V
750 V
1,000 V
1,000 V
DC voltage
600 V
600 V
1,000 V
1,000 V
1,400 V
1,400 V
Resistance
•
•
•
•
•
•
Audible continuity
•
•
•
•
•
•
•
•
•
•
•
•
Hold
•
•
ΔZero or ΔREL
•
•
Detailed product brochures can be downloaded free of charge from www.metrix.fr
•
•
•
•
•
•
•/•/•
•/•/•
•/•/•
•
•
1,000 V CAT III
•
•
600 V CAT IV
•
•
38
38
Range
•
•
Automatic power-off
•
•
•
•
300 V CAT III
•
•
•
•
600 V CAT III
Pages
34
•
•
•/•/•
Min / Max / Peak
The multilingual SX-DMM2 communication kit is easy to use
with the MX 26 for data acquisition on PC
1,400 A
AC voltage
Temperature
SX-DMM2 software kit
MX 26 communication accessory: RS optical cable
•
•
10,000-count display
Frequency
Specific accessories
•
•
Clamping ø 30 mm
Diode and semi-conductor tests
HX0056
•
RMS/TRMS measurement
4,000-count display
n The common software for all METRIX® multimeters: SX-DMM2
MX 350
36
36
37
37
•
35
www.metrix.fr
pocket multimeter clamps
V
1,000 a multimeter clamps
A
Hz
mx 350 & mx 355
A
Hz
mx 650 & mx 655
Comprehensive: all the functions needed by electricians in one hand.
Suitable for maintenance of electric machines.
n Compact, ergonomic multimeter
clamps
n Resistance and continuity
measurement
n Clamps for measuring high
currents and voltages
n Resistance, continuity and
frequency measurements
n Current measurement up to 400
AAC (MX 350) or 1,000 Aac and
1,000 Aac&dc (MX 355)
n Frequency measurement
(MX 350)
n Current measurement up to
1,000 Aac (MX 650) or 1,000 Aac
and 1,000 Aac&dc (MX 655)
n RMS measurements (MX 655)
n AC & DC voltage measurement up
to 600 V
n LCD screen with bargraph
n AC & DC voltage measurement up
to 1,000 V
n Differential current, voltage and
resistance measurements
Specifications
n Automatic zero DC (MX 355)
MX 350MX 355
Display
4,000 counts
Bargraph
42 segments
Clamping diameter
26 mm 30 mm
Type of acquisitionAVG
Range selection
Automatic Automatic or Manual
AC current
0.05 A to 400.0 A
Basic accuracy
1.9 % +5 D
2% of reading + 10 D
Bandwidth
50 to 500 Hz
DC current
-
0.1 A to 400 A
Basic accuracy
-
2.5% of reading + 10 D
AC voltage
0.5 V to 600 V
Basic accuracy
1.5% of reading + 5 D
Bandwidth
50 to 500 Hz
DC voltage
0.2 V to 600 V
Basic accuracy
1% of reading +2 D
Resistance
0.2 to 399.9 Ω
Basic accuracy
1% of reading + 2D
Audible continuity
≤ 40 Ω
Frequency
Current: 20 Hz to 10.00 kHz
Voltage: 2 Hz to 1 MHz
Basic accuracy
0.1% of reading + 1D
Fonctions
HoldHold
∆Zero
Range
Automatic shutdown
30 min. 30 min., can be deactivated
Power supply
2 x 1.5 V (AAA)
Electrical safety
CAT III 300V / CAT II 600V
Dimensions / Weight
193 x 50 x 28 mm / 230 g
36
V
Standard state at delivery
References to order
1 MX 35x multimeter clamp delivered
with 1 set of measurement leads with
test probes, 1 soft case, 2 x 1.5 V AAA
alkaline batteries and 1 user manual in
5 languages
MX0350-Z: 1 MX 350 clamp
MX0355-Z: 1 MX 355 clamp
Specifications
n Min-Max and Peak 1 ms analytical
functions
MX 650MX 655
Display
4,000 counts
Bargraph
42 segments
Clamping diameter
36 mm
40 mm
Type of acquisition
AVGRMS
Range selection
Automatic or manual
Automatic
AC current
0.05 A to 1,000 A
Basic accuracy
1.9% of reading + 5 D
Bandwidth
50 Hz to 1 kHz
DC current
-
0.10 A to 1,000 A
Basic accuracy
-
2.5% of reading + 10 D
AC voltage
0.5 V to 750 V
Basic accuracy
2.5% of reading + 10D
Bandwidth
50 Hz to 1 kHz
DC voltage
0.2 V to 1,000 V
Basic accuracy
0.75% of reading + 2 D
1% of reading + 2 D
Resistance
0.2 to 4,000 Ω
Basic accuracy
1% of reading + 2 D
Audible continuity
≤ 100 Ω
Diode test and semi-
Itest ≤ 0.6 mA / Vtest ≤ 3.3 VdcItest ≤ 1.7 mA / Vtest ≤ 6 Vdc
conductor junction test
Frequency
Current: 20 Hz to 10 kHz
Voltage: 10 Hz to 10 kHz
Basic accuracy
0.1% of reading + 1 D
Fonctions
Hold. Peak (1 ms). Max-Min. Hold. Peak (1 ms).
∆REL. Range
Max-Min. ∆REL
Automatic shutdown 30 min., can be deactivated
Power supply
1 x 9 V 6LF22 battery
Electrical safety
IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033 - 600_V CAT III
Dimensions / Weight
246 x 93 x 43 mm / 400 g
Standard state at delivery
References to order
1 MX 65x multimeter clamp delivered
with 1 set of measurement leads with
test probes, 1 soft case, 1 x 9 V alkaline
battery and 1 user manual in 5 languages
MX0650-Z: 1 MX 650
MX0655-Z: 1 MX 655
Available accessories
Available accessories
See pages 96 to 107
See pages 96 to 107
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
37
For further details…
DUAL-DISPLAY TRMS MULTIMETER CLAMPS
V
A
ON-SITE wattmeters
Hz
mx 670 & mx 675
n Voltage up to 1,400 V
n Dual 10,000-count backlit display
n Temperature measurement
n CAT IV 600 V
Specifications
MX 670MX 675
Clamping diameter
42 mm
40 mm
Display2 x 10,000 counts / backlighting
Type of acquisition
TRMS AC/DC
Range selectionsAutomatic
AC current
0.05 A to 1,000 A
Basic accuracy
1.5 % of reading +5 D
Bandwidth
50 Hz to 3 kHz
DC current
0.10 A to 1,400 A
Basic accuracy
1.2 % of reading +5 D
AC voltage
0.5 V to 1,000 V
Basic accuracy
1 % of reading +5 D
Bandwidth
50 Hz to 3 kHz
DC voltage
0.2 V to 1,400 V
Basic accuracy
1 % of reading +2 D
Resistance
0.2 to 9,999 Ω
Basic accuracy
1% of reading + 3 D
Audible continuity
≤ 35 Ω
Temperature-40.0 °C to +1,200 °C / -40 °F to +2,192 °F
Basic accuracy
1% of reading + 3 D
Frequency Current: 0.2 Hz to 9,999 Hz
Voltage: 10 Hz to 9,999 Hz
Basic accuracy1% of reading + 2 °C / 1% of reading + 4 °F
Functions
HoldHold
Peak (1 ms)
Peak (1 ms)
Min (500 ms)
Min (500 ms)
Max (500 ms)
Max (500 ms)
∆Zero
Automatic shutdown
10 min., can be deactivated
Power supply
1 x 9 V 6LF22 battery
Electrical safety
IEC 61010-1. IEC 61010-2-032. IEC 61010-2-033
600 V CAT IV / 1,000 V CAT III
Dimensions / Weight
272 x 80 x 43 mm / 480 g
257 x 80 x 43 mm / 440 g
38
Standard state at delivery
References to order
1 MX 670 or MX 675 multimeter clamp
delivered with 1 x 9 V alkaline battery,
1 user manual in 5 languages, 1 soft
case, 1 set of leads with Ø 4 mm test
probes and K-thermocouple sensor
MX 675: MX0675
MX 670: MX0670
A
VA
var
Designed for general and technical education, installers and industrial
maintenance teams, the PX 110 and PX 120 digital wattmeters can be used
both on-site and in the laboratory.
Px 110
Px 120
n Single and three-phase TRMS
digital wattmeter
n Single-phase TRMS digital
wattmeter
Specifications
PX 110PX 120
Network type
Single-phase Single and three-phase
Number of display counts 3 lines of 4 digits
Bandwidth
DC to 1 kHz
AC/DC active power 6 kW
Resolution
0.1 - 1 W
AC/DC basic accuracy 2 % R ± 3 D
1%R+2D
Apparent power (VA) 10 VA to 1 kVA
Reactive power (var)
1 VAR to 6 kVAR
Resolution
0.1 to 1
AC/DC basic accuracy
2%R±2D
Power factor 1
Resolution 0.01 / 3 % R ± 2 D
AC/DC voltage 500 mV to 600 Vrms
Resolution
100 mV
AC/DC basic accuracy 1 % R ± 3 D
0.5 % R + 2 D
Current
10 mA to 10 ARMS
Resolution
1 to 10 mA
AC/DC basic accuracy
1 % R ± 3 D
0.5 % R + 2 D
Inrush current 5 to 65 A (peak)
Resolution/accuracy 100 mA / 10 % R ± 2 D
IEC 61010 safety 600 V, Cat. III, pol.2
Interface and software Yes – RS232 optical link (option)
Auto power-off After 10 minutes
Power supply 6 x 1.5 V
Dimensions 60 x 108 x 211 mm
Weight 835 g
Accessories supplied 2 current cables and 2 voltage cables,
2 test probes, 6 batteries and 1 user manual
Accessories
HX 0011 wattmeter
switch
This makes it possible
to use the two wattmeter method with a
single wattmeter. This
allows measurements
on unbalanced 3-wire
3-phase systems. The polarity reversal switch
contains auxiliary contacts ensuring continuity of the current circuits during switching
operations.
The following measurements are possible for
frequencies of 50 to 60 Hz:
- AC voltages from 10 to 600 V,
- AC currents from 0 to 20 A
HX 0012 multi-ratio
transformer
Available accessories
See pages 96 to 107
W
Px 110 & Px 120
Extra protection for industry and electrical power distribution.
n 2 simultaneous TRMS
measurement channels
V
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
This can be used for
measurements on
loads whose power
consumption is higher than the specifications
of the wattmeter used. The following
measurements are possible for frequencies
of 50 to 60 Hz:
- AC voltages from 10 to 600 V,
- AC currents from 0 to 30 A
Wattcom
References to order
PX0110 : PX 110 wattmeter
PX0120: PX 120 wattmeter
HX0011: wattmeter switch
HX0012: multi-ratio transformer
HX0013: Wattcom software + RS232
cable
HX0021: PX 110 and PX 120 mains power
supply
P01330401: USB cable
P03295509: accessory for current
measurement
Multilingual data acquisition and processing
software for viewing
different quantities on
a PC screen, printing
screenshots or transferring measurement files into a spreadsheet
and storing them.
Accessories supplied with the Wattcom
software
RS232 optical cable
39
For further details…
COS PHI METER
on-site ELECTRICAL SAFETY TESTERS
V
A
mx 98
Electrical
installation testing
Designed for measuring the power factor on single-phase installations, this
instrument can be used in the laboratory, for professional training or on
industrial installations, i.e. wherever quick, accurate measurements are needed.
The instrument is equipped with an electrodynamic system with extremely
rugged suspension. This damping system ensures needle deflection without
vibrations. The anti-parallax mirror ensures highly accurate readings.
n Values of cos φ in both the
inductive and capacitive directions
n Bandwidth: 40 à 60 Hz
n Large dial with anti-parallax mirror
n Voltage calibres: 100, 240, 400,
500 V
n Meter suspension resistant to
mechanical stresses
n 2 voltage ranges
n Screw terminals on 4 mm banana
plugs
Specifications
n 5 A current calibre
n Inductive and capacitive Cos φ
(1 to 0.4)
n Accuracy: 2.5 %
MX 98
Calibres
0.4 inductive – 1 – 0.4 capacitive
Accuracy corresponding
±2.5 %
to a 90° difference at 50 Hz
Voltage
4 calibres : 100 V - 240 V - 400 V - 500 V
Current5 A
Dimensions / Weight
197 x 148 x 73 mm / 1.8 kg
The purpose of electrical safety testing is to ensure the safety of people and property in the event of a
fault on the installation. It can also be used for preventive maintenance, thus avoiding serious failures.
To guarantee safety, the CENELEC HD 384 standard specifies the requirements applicable to electrical
installations in buildings, with the following measurements in particular:
Earth measurement with stakes
Insulation measurement
The earth stake must have a resistance lower
than 100 Ω to allow any faults to drain to earth.
When there is sufficient room to set up stakes,
this measurement can be performed using the
3P method with stakes, also known as the "62 %
method". The earth bar must be disconnected
during this measurement.
Insulation measurement, usually performed between
active conductors and the earth, involves applying a
250 V, 500 V or 1,000 Vdc test voltage, depending
on the operating voltage of the installation. The
insulation resistance value must be at least 1 kΩ per
volt of the test voltage (usually 500 kΩ /1 MΩ).
Earth measurement without stakes by
measuring the earth loop
At least one pulse-mode trip test must be performed
on the RCDs on the installation to check the trip
time.
When the 62 % method is not applicable, you can
use the stakeless method which involves measuring
the earth loop. This measurement can be performed
on live installations and does not require any stakes.
This method provides an overall value rounded up
from the real earth value.
Continuity measurement
The continuity of the protective conductors is
measured with a test current of at least 200 mA.
The resistance measured must be below a threshold
which is usually 2 Ω.
Reference to order - Etat de livraison
40
MX098: 1 cosphymètre MX 98 et 1 pile
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Residual Current Device testing
Other test and measurement operations
Current measurement using a clamp coupled to an
installation tester helps to detect existing leakage,
as well as possible phase unbalance on three-phase
installations.
You are also advised to test the lightning arresters
to ensure that they will do their job in the event of
a voltage surge due to lightning on the installation.
41
on-site ELECTRICAL SAFETY TESTERS
Analogue insulation tester
on-site ELECTRICAL SAFETY TESTERS
Insulation tester
V
mx 407
mx 406B
n Insulation measurement at 50,
250 and 500 Vdc
n Quick and easy readings with the
colour-scale dial
n Voltage measurement up to
440 Vac/dc
n Hands-free use with remote
control probe
n Continuity (200 mA)
With the MX 407, you get two tools in one as it is a megohmmeter equipped
with all the functions of a multimeter as well.
n Insulation at 250 / 500 / 1,000 V
n AC or DC voltage measurement
up to 600 V
n Insulation resistance up to 4 GΩ
Specifications
Insulation Continuity with buzzer Voltage Electrical safety Power supply
Dimension / Weight Standard state at delivery
Reference to order
MX406B: 1 MX 406B tester delivered with 1 remote-control probe,
1 black safety lead, 1 black crocodile clip, 3 x 1.5 V batteries and 1 user manual
MX0406B: 1 MX 406B tester
Insulation tester
mx 604
Lightning arrester tester.
n Probe with remote-control button
for in-situ measurements
Specifications
n Continuity with 200 mA test
current
n Dual analogue and digital display
on wide backlit screen
MX 406B
10 kΩ to 200 MΩ at 50/250 and 500 Vdc (3 ranges)
0 to 10 Ω (i > 200 mAdc)
0 to 440 Vac/dc
IEC 1010 – 300 V CAT III
3 x 1.5 V batteries for 1,000 x 5 s measurements
155 x 98 x 40 mm / 410 g
n Lightning-arrester support module
for measurements on unmounted
lightning arresters
V
n Measures insulation resistance at
50, 100 and 500 Vdc
n Quick and easy readings with the
colour-scale dial
Specifications
MX 407
Voltage
Range
0 to 600 Vac/dc
Accuracy
±0.8 % ± 3 cts (DC)
±1.2 % ± 10 cts (AC)
Insulation
Test voltage 250 V
10 kΩ to 4 GΩ
500 V
10 kΩ to 4 GΩ
1,000 V
10 kΩ to 4 GΩ
Accuracy
Range 4 MΩ/40 MΩ
±2 % ±10 pts
Range 400 MΩ
±2 % ±5 pts
Range 4 GΩ
±4 % ±5 pts
Voltage alert indicator
Yes > 25 V
Test inhibition
Yes > 25 V
Continuity
Range
0 to 400 Ω
Measurement current > 200 mA
Cable compensation
Yes
Buzzer
Buzzer triggered if < 35 Ω ± 3 Ω
Resistance
Range
0 to 400 kΩ
Accuracy
±1.2 % ± 3 cts
Automatic power-off
After 10 minutes without use
Display / Backlighting
LCD + bargraph / Yes
Power supply
6 x 1.5 V AA batteries
Electrical safety
IEC 61010 600 V CAT IV / / IEC 61557-3-4
Dimensions / Weight H 200 x L 92 x W 50 mm / 700 g (with batteries)
MX 406B
Lighting arrester test 0 to 600 Vdc
Insulation 100 kΩ to 2,000 MΩ at 50/100 and 500 Vdc (3 ranges)
Battery test Yes
Electrical safety
IEC 1010 – 300 V CAT III
Power supply
3 x 1.5 V batteries for 1,500 x 5 s measurements
Dimension / Weight 155 x 98 x 40 mm / 350 g
Standard state at delivery
Standard state at delivery
1 MX 407 insulation tester delivered in
"hands-free" bag with 1 set of leads 1.5 m
long (red/black), 1 black test probe, 1 red
crocodile clip, 6 x 1.5 V AA batteries and
1 user manual in 5 languages
1 MX 604 delivered in a hard case with 1 detachable lightning-arrester support
module, 1 remote-control probe, 1 red test probe, 1 black straight-straight lead 1.5 m
long with built-in test probe, 1 black crocodile clip, 1 lightning-arrester support
clamp, 1 strap mounted on the instrument, 3 batteries, 1 user manual in 5 languages
42
Reference to order
Available accessories
MX0604: 1 MX 604 tester
See pages 96 to 107
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Reference to order
Available accessories
MX0407: 1 MX 407 tester
See pages 96 to 107
43
For further details…
on-site ELECTRICAL SAFETY TESTERS
Multi-function
installation tester
V
TRAINING EQUIPMENT DISDASCOPES - VOLTMETERS - AMMETERS
Analogue voltmeter
and ammeter
A
mx 435D
A
mx 125 & mx 135
Quick, simple testing of electrical installations in compliance with the
CENELEC HD 384 (NF C 15-100) standard.
n Compact and lightweight, ideal for
intensive use
n Earth measurement without
stakes by measuring the earth
loop
n 3-wire lead with 2P+E plug for
quick, error-free measurement on
the installation
Specifications
Voltage 3P earth Earth loop Continuity + buzzer Insulation
RCD test
Test calibres
Type of test
Current (with clamp option)
Electrical safety
Power supply Dimensions Weight
V
n Powered by rechargeable battery
(batteries and charger supplied)
Designed to withstand mechanical shocks, protected by high-rupturecapacity fuses.
n Equipped with a moving-coil galvanometer:
- Safety: IEC61010 - 600 V CAT III
- Ingress protection: IP65
n Immediate error-free connection
thanks to colour-coding of the
terminals and the switch
n Continuity with buzzer and
fuseless protection against
external voltages
MX 435D
0 to 600 Vac
0.10 to 1,999 Ω (2 calibres)
0.10 to 1,999 Ω (2 calibres)
0.10 to 19.99 Ω (i > 200 mAdc)
0.5 to 199.9 MΩ at 500 Vdc
30 mA / 100 mA / 300 mA / 500 mA / 650 mA
Pulse
1 mA to 200 A
IEC 1010 – 300 V CAT III - IEC 61557 1-2-4-5-6
Rechargeable battery (as standard)
Possibility of operation with 2 x 9 V batteries
195 x 97 x 55 mm
670 g
Specifications
MX 125MX 135
Length of scale
83 mm
Bandwidth
16 to 1 kHz
Voltage
9 DC calibres (150 mV to 1,500 V)
6 AC calibres (5 mV to 1,500 V
Current 7 DC calibres (50 µA to 10 A)
6 AC calibres (500 µA to 10 A)
Ri
20 kΩ
Dimensions / Weight
155 x 99 x 40 mm / 350 g
Specifications
Vdc
Vac
Ranges Accuracy
Ri
Ranges (V)
Accuracy
Ri
MX 125
9 (150 mV, 0.5 V, 1.5 V, 5 V, 15 V, 50 V, 150 V, 500 V, 1,500 V)
2%
20 kΩ/V
6 (5, 15, 50, 150, 500, 1,500)
2.5 %
6.32 kΩ/V
Standard state at delivery
1 MX 435D delivered in a hands-free bag, 1 set of 2
measurement leads 1.5 m long (red/black), 2 crocodile clips
(red/black), 2 test probes (red/black), 1 battery charger,
1 measurement lead with European mains plug and 1 user
manual
Specifications
Idc
Iac
Specific accessories
Continuity rod . . . . . . . . . . P01102084A
Adapter for MX435D loop
measurement . . . . . . . . . . . . . . HX0092
Ranges Accuracy
Protection
Ri
Ranges (V)
Accuracy
Protection
MX 135
7 (50 µA, 500 µA, 5 mA, 150 mA, 500 mA, 1.5 A, 10 A)
2%
10 A and 1.6 A fuses (HRC 600 V)
1.2 kΩ
6 (500 µA, 5 mA, 150 mA, 500 mA, 1.5 A, 10 A)
2.5 %
10 A and 1.6 A fuses (HRC 600 V)
MN73 200 Aac / 2 Aac current clamp
P01120421
The complete
50 m earth kit
Earth kit:
15 m basic earth kit . . . . . . . P01102019
50 m earth kit . . . . . . . . . . . . P01102021
44
Reference to order
Available accessories
MX0435D
See pages 96 to 107
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Standard state at delivery
References to order
Available accessories
MX125: 1 MX voltmeter and user manual
MX135: 1 MX ammeter and user manual
MX125: MX125 voltmeter
MX135: MX135 ammeter
See pages 96 to 107
45
analogue OSCILLOSCOPES
digital OSCILLOSCOPES
Introduction
Introduction
Analogue oscilloscope with cathode ray tube
This is an instrument which allows users to view,
as a function of time, the waveform of a periodic
electrical signal or a single event. because it is
based on digital processing, it allows storage of the
signals and automatic measurements and transfer
of the data onto a PC.
This is an instrument for "qualitative analysis" which
can be used to view the waveform of a periodic
electrical signal as a function of time.
Choosing your analogue oscilloscope
Vertical deflection
Deflection coefficient
This defines the minimum amplitude (sensitivity)
and maximum amplitude values accepted by the
input Y.
Bandwidth (BW)
This is the maximum admissible frequency range
for the oscilloscope (MHz).
Rise time (rt)
For a square signal (steep edges), this is the time
necessary for the rising edge to pass from 10 % to
90 % of the "peak to peak" amplitude.
Horizontal deflection
Time base (TB)
It is the oscilloscope's circuits which control the
screen sweep. The choice of the "time base
coefficient" enables the signals to be displayed
over an appropriate duration.
Alternate or Chop display
46
Multiplexing of the channels allows display of
Choosing your digital oscilloscope
several channels, Y1, Y2, … Y4, with a single
electron beam. In alternate mode, each of the
traces performs a complete sweep of the screen,
alternately. For slow speeds, portions of the trace
to be displayed during a given screen sweep are
cut up: chop mode.
Sampling frequency (or rate)
Deflection coefficient
This is the reciprocal of the sampling interval and
it is expressed in MegaSamples per second (MS/s).
It varies according to the sweep speed. According
to Shannon's theorem, for a pure sinusoidal signal,
this frequency must be at least twice the frequency
of the signal to be observed. In practice, the
oscilloscope must sample at a frequency at least
10 times the presumed frequency of the signal.
The "useful bandwidth" will be one tenth of the
maximum sampling frequency and will be expressed
in MegaHertz.
This defines the minimum amplitude (sensitivity)
and maximum amplitude values accepted by the
input Y.
Sampling modes
Memory depth
This is expressed in kilo points (kpoints). It
determines the "recording duration" according to
the sweep speed; the larger it is, the longer the
recording duration. Conversely, an instrument with
ten times more memory capacity can sample 10
times quicker for the same recording duration.
Vertical resolution
This defines the minimum amplitude (sensitivity)
and maximum amplitude values accepted by the
input Y.
"Quantification" involves converting the value of a
sample into a binary number. The vertical resolution
is defined by the capacity in bits of the Analogue/
Digital Converter (ADC). It is 1/256 or 0.4 % for an
8-bit ADC (28 = 256).
Trigger
Signal processing
Deflection coefficient
This is a circuit which authorizes the horizontal
sweep and determines the signal's starting point.
The "trigger level" is the voltage level which must
be reached by the signal observed in order to
sweep. Alternate triggering provides stable display
of the traces in all cases.
XY function
This is a function which allows display of one
channel (Y1) as a function of another channel (Y2)
on screen; the time base is then inoperative.
Detailed product brochures can be downloaded free of charge from www.metrix.fr
For "real-time" or "one-shot" sampling, all the
samples are acquired in a single sweep. "Equivalent
time" sampling can be used to achieve higher
"sampling frequencies" because the samples are
acquired in several successive sweeps. This mode is
reserved for periodic signals.
This involves very useful mathematical operations
between signals:
+, -, *, and even complex functions (Fourier transform
or FFT, harmonic analysis, etc.).
47
www.metrix.fr
digital OSCILLOSCOPES
ANALOGUE & [email protected] OSCILLOSCOPES
The different types of "measurement" inputs on
oscilloscopes
Selection guide
Traditional metal BNC inputs
Class 1 unisolated oscilloscopes
The inputs of traditional unisolated oscilloscopes
are equipped with BNC connectors. They comprise
a "hot point" connected to the central conductor
of the BNC and a "cold point" connected to the
metal enclosure of the BNC.
4 mm banana safety inputs
Class 2 double-insulated oscilloscope with
channels not isolated from one another
The inputs of double-insulated oscilloscopes are
equipped with two 4 mm banana plugs, one
for the hot point and the other for the cold
point or reference. The cold point or reference
is isolated from the earth, so it is floating. When
an oscilloscope has several channels (OX 71), the
cold points or references of the channels are
linked together and isolated from the protective
earth.
In these oscilloscopes, it is possible to have a
cold-point / reference potential different from the
potential of the protective earth.
BNC safety inputs with metal enclosures
insulated during use
Class 2 double-insulated oscilloscopes with
channels isolated from one another
The inputs of double-insulated oscilloscopes with
channels isolated from one another are equipped
with BNC connectors with metal enclosures
insulated when the measurement lead is connected.
The cold point or reference is isolated from the
earth and the cold points or references of the
other channels.
[email protected]
Remote screen
Lab Didactic
Lab
Analogue
Mtx 1052
Mtx 1054
Mtx 162
Mtx 112
Ox 71
Ox 803B
Ox 530
200 MHz
60 MHz
10 MHz
5 MHz
30 and 40 MHz
2 ou 4 /class 1
2 /class 1
2 /Differential
1 + X / isolated
2 / class 1
CATII 300V
CATII 300V
CATII 600V
CATII 400V
CATII 300V
One-shot digital sampling
200 MS/s
50 MS/s
50 MS/s
-
-
ETS repetitive mode
100 GS/s
20 GS/s
20 GS/s
-
-
9 bits
8 bits
8 bits
-
-
•/•
•/•
•/-
-
•/-
-
-
Families
Bandwidth
Channels (number/type)
IEC61010 safety
Analogue display or equivalent
Vertical resolution
Detection of transients (Glitch)
Scaling / Physical unit
PC communication via Ethernet
10Mb Ethernet + Web server
•
Mains power supply / Battery
Integrated mode
OX-REC
OX
OX
"Oscilloscope" specifications
Max. input sensitivity
2.5 mV/div
5 V/div
20 mV/div
50 mV/div
1 to 5 mV/div
Max. input amplitude
100 V/div
100 V/div
100 V/div
5 V/div
5 to 20 V/div
15 MHz, 1.5 MHz,
5 kHz
15 MHz, 1.5 MHz,
5 kHz
1 ns-200 s
5 ns-100 s
100 ns-200 s
500 ns-0.5 s
"5 or 10 ns
0.1 or 0.2 s"
•/•
50 k / channel
•/•
50 k / channel
•/•
50 k / channel
-/•
-
-/•
-
PC hard disk
PC hard disk
PC hard disk
-
-
No. of reference or math curves on screen
4
2
2
-
-
Envelope/Averaging modes
-
-
-
-
-
SPO (Smart Persistence Oscilloscope)
•
•
•
-
-
20/•
20/•
19/•
-
-/•
•/•
•
-
-
-
•
-
-
-
-
-
-
Analogue filter
Time base (per division)
Roll mode/ XY mode
"Memory depth Acquisition memory"
4 mm banana safety inputs
Class 1 differential oscilloscopes
The inputs of differential oscilloscopes have two 4
mm banana plugs per channel: one for the + hot
point and the other for the - hot point. The 2 hot
points (+ and -) are equivalent because they have
the same impedance in relation to the earth.
If the oscilloscope has several channels, all the
+ and - hot points have the same impedance in
relation to the earth.
Automatic measuremens/Cursors
Pulse trigger on width/number
Video trigger (line counter)
Trigger on measurement & Automatic backup
Adjustable Hold-Off / Delay
Calculation functions + - / x / : / Advanced
Autoset with selection of channels
-
20 MHz
-
-
-
•/•
•/•
•/•
•
•
•
-
•
9 bits / 54 dB
8 bits / 48 dB
8 bits / 48 dB
-
-
31 orders
-
-
-
-
2 or 4
-
-
-
-
PC screen
PC screen
PC screen
-/-/•
-/-/•
•
•
•
-
-
•/•
-
-
-
-
54-55
52
53
56
56
(1)
•/-/-/-
Other functions
Etalonnage soft 100% "boitier fermé"
Analyse d'harmoniques
Enregistreurs seuils (nombre de voies)
General specifications
LCD colour screen / B&W / Tube
100% "closed casing" soft calibration"
ScopeNet PC web server/ANDROID app
Pages
48
49
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
digital OSCILLOSCOPES
digital OSCILLOSCOPES
[email protected] screenless oscilloscopes
Oscilloscopes connected to a PC DIDASCOPES
PC ergonomics and environment
Compact, economical and simple to use, the MTX112
and MTX162 screenless measuring instruments
in the [email protected] range benefit from the same
high performance and know-how as all Metrix®
oscilloscopes. When connected to a PC, they take
full advantage of all its useful features (large screen,
unlimited storage capacity, etc.).
The MTX 1052-PC, MTX 1054-PC & MTX 162 are
genuine "scopes in a box". Compact, lightweight
and stackable, these measuring instruments can be
connected directly to a PC via a USB or Ethernet
interface with
dedicated PC
software. The
Wifi
versions
now allow wireless
Ethernet
communication.
Users benefit from all the
PC's advantages in terms
of storage capacity (PC
storage capacity) and display (minimum resolution
1024x768), allowing more
precise analysis of the
[email protected] control panel.
curves. The functions are
General commands
directly accessible from
the menus and the Windows toolbar by means of
keyboard shortcuts or the mouse. Users control
the oscilloscope using the "instrument" control
panel, which contains all the commands found on
normal oscilloscopes. Online help is also available.
M u l t i windowing
enables simultaneous display of the
traces,
the
zoom, the FFT
analysis and
[email protected] Display of "X(t)" traces
in SPO mode
the measurements... In this way, users can obtain multiple
combinations and check out all the relevant information at a glance.
The MTX 1052 & MTX 1054 offer the SPO (Smart
Persistence Oscilloscope) display mode. This principle combines the advantages of analogue and
digital oscilloscopes. It can be used to manage the
display and acquisitions simultaneously, making it
possible to increase the acquisition rate to several
tens of thousands per second. With SPO, users
can detect brief events, instabilities and untimely
anomalies.
The MTX 162, an oscilloscope with a "double time
base", allows both normal display and remanent
display (like on an analogue oscilloscope).
Universal communication
Each
oscilloscope
benefits from a universal USB communication mode and a 10 Mb
Ethernet interface for
integration in a local or
remote network. When
The "W" versions of the [email protected]
started up in USB or
BOX models offer built-in Wifi
communication.
ETHERNET mode, the
software automatically detects the instruments
connected to the PC or to the network. "Unlimited"
storage of the traces is possible simply by saving
the files. Firmware upgrades are automatic. It is
also possible to export results into Excel or print in
Word with just 1 or 2 clicks.
MTX112 10 MHz differential training oscilloscope (Didascope)
PC ergonomics and environment
Keyboard shortcuts
The [email protected] simplified PC software
automatically detects the oscilloscope connected to
the PC's USB port and starts it up. The software automatically opens a control panel and a trace window.
The "READY" LED on the front panel switches off
when the PC has taken control of the instrument.
The most frequently-used oscilloscope functions
are assigned to keys on the PC keyboard.
Remanent display.
Double time base in real time.
Multi-window display for simultaneously
observing:
• The f(t) signal, its FFT and the table of automatic measurements.
• The f(t) signal of channels CH1 and CH2 with its
XY representation, etc.
• The signal captured at a given moment and its
evolution in real time
Secure firmware releases
The firmware upgrades are performed with the
instrument in operation. This takes 3 minutes and
the instrument automatically restarts with the new
software version if the transfer has been completed correctly, If not, the instrument restarts with
the old software version.
Simple to use
Autoset and Vertical/Horizontal Autorange modes.
General Autoset: Vertical – Horizontal – Trigger.
Differential capture of the signals with banana
leads with the MTX112, just like with a multimeter.
MTX105X: ScopeNet for Android tablets and smartphones can be
downloaded free from Google Play
50
HX0112 - Training kit
51
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
DIGITAL OSCILLOSCOPES
DIGITAL OSCILLOSCOPES
Oscilloscope connected to a PC
[email protected]
MTX 162
MTX 112
Compact, economical and simple to use, this screenless measuring
instrument [email protected] benefits from the same high performance and knowhow as all Metrix® oscilloscopes. When connected to a PC, it takes advantage
of all its useful features (large screen, unlimited storage capacity, etc.).
n Multiple functions: Oscilloscope,
FFT Analyser and Recorder
n Normal or remanent display (like
on an analogue oscilloscope)
n Deactivatable vertical and
horizontal autorange functions to
simplify operation
n Simplification of the connections
with signal capture using banana
leads, like on a multimeter
n Multi-windowed display
to observe all the signals
simultaneously
n Communication: USB, Ethernet
and Wifi (MTX 162UEW)
n A Windows environment with
quick display refresh in real time
n [email protected] simplified
training software in addition to
the complete [email protected] LE
software in a single software
installation
n Automatic detection of the
available instruments connected
to the PC via USB or the Ethernet
network
Specifications
MTX 162
Quick selection
Bandwidth
60 MHz (bandwidth limiter: 15 MHz, 1.5 MHz or 5 kHz)
Number of channels
2 channels, Class 1, common chassis-earths
Sampling rate per channel
Repetitive = 20 GS/s – One-shot = 50 MS/s
Digital oscilloscope
Vertical sensitivity
8 bits
Sweep speed
32 calibres from 5 ns to 100 s/div
Memory capacity
Depth = 50,000 points
Automatic measurements
19 measurements + Automatic phase
On any type of curve – Markers and limits
Triggering
Mode
Auto, Triggered, One-shot ROLL, auto level at 50%
Sources CH1, CH2, mains
Type
Rising or falling edge, pretriggering adjustable from 0 to 100 %
Digital recorder
Recording duration 2 s to 33 minutes
Acquisition mode
Dedicated ROLL mode
General specifications
"Windows-like" with online help – all commands accessible with mouse
Screen commands
USB type B and Ethernet RJ45
Communication
(10 Mb local or remote communication), Wifi (MTX 162UEW)
Dimensions / Weight
270 x 213 x 63 mm / 1.8 kg
Warranty
3 years / France
Standard state at delivery
1 MTX 162 oscilloscope delivered with 2 x 100 MHz probes (HX0210), 1 standard
USB A/B cable, 1 removable mains power cable and a CD-Rom containing the PC
software, the user manual in 5 languages, the programming guide and the drivers
References to order
52
MTX162UE: MTX162 USB+Ethernet
MTX162UEW: MTX162+WIFI
Available accessories
See pages 110 to 118
The MTX112U is the first screenless digital oscilloscope with 600 V CAT II
differential inputs and also the easiest to use. This 10 MHz differential
training oscilloscope is also an FFT analyser.
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Specifications
Quick selection
Bandwidth
Number of channels
Maximum sampling rate
Vertical resolution
Display mode
Oscilloscope mode
Vertical sensitivity
Sweep speed
Memory depth
Number of curves on screen
Automatic measurements
Other functions
FFT mode
Analysis range
Trigger
Modes
Sources
Type
Coupling
Sensitivity
Digital data storage
File management
GLITCH mode
(transient capture)
Display modes
XY mode
General specifications
PC screen commands
Configuration memories
PC interfaces
Safety / EMC
Dimensions / Weight
Warranty
MTX 112
10 MHz
2 channels, Class 1, differential channels
Repetitive = 20 GS/s – One-shot = 50 MS/s (on each channel)
8 bits
8 x 10 divisions - Multi-window (control panel, complete trace, zoomed trace, FFT, XY, measurements, etc.)
12 calibres from 20 mV to 100 V/div
29 calibres from 100 ns/div to 200 s/div
Acquisition depth = 50,000 points – "unlimited" storage capacity (PC storage capacity)
2 curves + 2 references
19 time or level measurements and Phase measurement with [email protected] LE and 5 time measurements
with [email protected] Markers and Limits on all types of curves
AUTOSET, +, -, x, /, cursors: dv, dt, 1/dt, phase - cursors linked to the trace or free
2.5 kpoints on 2 channels
Automatic, Triggered, One-shot and ROLL
CH1, CH2, mains (LINE)
Rise and falling edge
AC, DC
0.5 div, adjustment of trigger level ±8 div.
Trace or text (compatible with Windows) for the signals and configuration in [email protected] LE
and text only with [email protected] Screenshot file
(depending on Windows print manager configuration)
Detection and display of the Min & Max amplitudes between 2 samples - Event duration ≥ 20 ns
Vector, Envelope, Averaging (factor 2,4 or 8) and Remanence
CH2 versus CH1
100 % of commands by mouse, "Windows-like menus" & online help – keyboard shortcuts
"Unlimited", depends on PC configuration
USB B connector – "Ready" LED on front panel - indication of front-panel test by PC
Safety as per IEC 61010-1 (2001) – 600 V CAT II – EMC as per EN 61326-1
270 x 213 x 63 mm / 1.8 kg
3 years
Standard state at delivery
Specific accessories
Reference to order
1 MTX 112U, 1 mains lead, 2 set of
Ø 4 mm leads with test probes,
1 USB A/B cable, CD-ROM
with [email protected] LE and
[email protected] software, 1 user
manual in 5 languages, 1 programming
manual in French and English + drivers
HX0112, DICABOX DIFF MTX
Training module including exercises
with mains power supply for MTX112U
MTX112U: 1 oscilloscope with 2 x 10 MHz
channels and USB
Available
accessories
See pages 110 to 118
For further details…
53
digital OSCILLOSCOPES
digital OSCILLOSCOPES
Specifications
SPO
FFT
50 kpts
• REC
Oscilloscopes connected to a PC
MTX 1052 & MTX 1054
In addition to the same performance as traditional
oscilloscopes, the [email protected] models also offer the advantage of ergonomics as compact as
their price! When connected to a PC, they make full
use of all its performance features (large, unlimited
storage capacity, etc.), while remaining easy to set
up and use.
Versatile
Ergonomic
With 4 instruments in 1 for optimum efficiency
(oscilloscope, real-time FFT analyser, harmonic
analyser and logger), these high-performance oscilloscopes are designed for laboratory applications
in electronics, power electronics and electrical
engineering.
• Takes full advantage of the PC screen's size and
high resolution
• Multi-windowing with trace, FFT, zoom and automatic measurements simultaneously
• "Windows" environment with familiar ergonomics
• Large storage capacity, direct use of files in
Windows (Excel, Word, images, etc.), printing in
Windows, etc
• ScopeNet web server on PC, tablet or Android
smartphone.
High-performance
• 2 or 4-channel oscilloscopes, 200 MHz.
• Quick acquisition mode and "SPO" Smart
Persistence Oscilloscope display mode.
• Resolution doubled by the 9-bit converter.
• Vertical sensitivity from 250 μV/div to 100 V/div.
• Acquisition depth of 50,000 points per channel.
• Advanced trigger functions (pulse, delay, counting, main/auxiliary channel, fault capture, etc.).
54
MTX 1052MTX 1054
Quick selection
Bandwidth
150 MHz (Bandwidth limiter: 15 MHz, 1.5 MHz or 5 kHz) or 200 MHz
Number of channels
2 channels, Class 1, common chassis-earths
4 channels, Class 1, common chassis-earths
Sampling rate per channel
Repetitive = 100 GS/s – One-shot = 200 MS/s (2 channels), 100 MS/s (4 channels)
Vertical resolution
9 bits
Display mode
8 x 10 div.- Multiple windows (control panel, trace, zoom, FFT, etc.)
Probe factors
Scaling of complete physical signal + choice of unit ("windows" virtual keyboard)
Digital oscilloscope
Vertical sensitivity250 µV to 100 V/div
Sweep speed
35 calibres from 1 ns to 200 s/div
Data storage capacity
Memory depth = 50,000 points – storage capacity depends on the configuration of the PC used
Number of curves on screen
4 curves + 4 references
Automatic measurements
19 measurements + automatic Phase –On all types of curves - Markers and limits
Other functions
FFT (calculated over 2,048 points), +, -, x, / - "Made-to-measure" function editor
SPO (Smart Persistence Oscilloscope)
Duration of persistence
100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s and Infinite
Display
Monochrome or colour
Performance
Acquisition speed 50 kwaveforms/s/channel, No. of samples acquired: 19 MS/s/channel
Harmonic analyser
Analysis range
Fundamental + 31 orders, on 1 to 4 channels and fundamental from 40 Hz to 1 kHz simultaneously
Processing
Permanent display: total RMS value & THD – Selected order: %F, phase, freq, Vrms
Trigger
Mode
Auto, Triggered, One-shot
Source
CH1, CH2, EXT, Mains
CH1, CH2, CH3, CH4, Mains
Type
Edge, pulse width or delay (40 ns-10.5 s), Counting (2-16,384 events),
TV (525 = NTSC, 625 = PAL/SECAM),
Adjustable pre-triggering from 0 to 100 %, Hold-off (40 ns-10.5 s)
Coupling
AC, DC, HFR (HF rejection), LFR (LF rejection)
Sensitivity
0.6 div up to 10 MHz, 1.5 div from 10 MHz to 150 MHz
(CH1, CH2, CH3 or CH4)
Trigger level +/- 8 div.
Digital recorder
Sampling interval40 μs to 53.57 s
Recording duration
2 s to 31 days
Acquisition mode
Conditioned by thresholds on 4 channels
Mode for capture of 100 faults in working memory
Processing
Time/date-stamped recordings, conversion and units of physical quantities,
measurements by cursors and event search,
file format compatible with standard spreadsheets (.txt)
General specifications
Screen commands
"Windows-like" & online help – 100 % of commands with mouse
Communication
USB type B and Ethernet RJ45 (10 Mb local or remote communication),
HTML server + Wifi, PC or Android tablet
Dimensions / Weight
270 x 213 x 63 mm / 1.8 kg
Warranty
3 years
Communication experts
• Equipped with a USB link and Ethernet with integrated web server
• 100%-programmable using the SCPI standard,
delivered with LabWindows and LabView drivers
• Products designed for integration in test benches
(19" rack versions)
Standard state at delivery
LX 1600-PC logic analysis probe specially
for BUS decoding!
1 MTX, 1 mains cable, 2 voltage probes, 1 Ethernet crossover
cable, 1 Ethernet straight cable, 1 USB cable, 1 CD-Rom
containing the [email protected] PC software
• When the MTX 1052 and MTX 1054 oscilloscopes
are used with the 16-channel logic analyser on
PC (LX1600-PC), they allow decoding of a large
number of buses: UART, I2C, SPI, CAN, LIN,
Modbus, etc.
• Oscilloscope acquisition can be synchronized on
the basis of the logic analyser trigger conditions.
References to order
Self-contained bus-decoding probe powered via USB
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
MTX1052B-PC: MTX1052 2 x 150 MHz channels
MTX1054B-PC: MTX1054 4 x 150 MHz channels
MTX1052BW-PC: MTX1052B-PC, Wifi version
MTX1054BW-PC: MTX1054B-PC,WiFi version
MTX1052CW-PC: MTX 1052C, 2 x 200 MHz channels, Wifi version*
MTX1054CW-PC: MTX 1054C, 4 x 200 MHz channels, Wifi version*
MTX1052B-RK: MTX1052B-PC, RACK version
MTX1054B-RK: MTX1054B-PC, RACK version
MTX2022W-PC: MTX1052CW-PC oscilloscope + LX1600-PC probe
MTX2024W-PC: MTX1054CW-PC oscilloscope + LX1600-PC probe
Specific accessories
When used with the MTX 1032 double differential probes,
they allow effective measurements in total safety on all
the sub-assemblies not referenced to earth or possessing
differentiated chassis-earths
LX1600-PC: Logic Analysis probe, USB A/B cable, test
cables and associated wire-grips, CD-Rom containing the
[email protected] Analysis PC software, usable only with
a [email protected] BOX
Available accessories
See pages 110 to 118
55
For further details…
analogue OSCILLOSCOPES
LABORATORY DIGITAL OSCILLOSCOPES
Analogue oscilloscopes with cathode-ray tubes
Selection guide
OX 530 & OX 803B
OX 6000 & DOX 2000 family
Analogue oscilloscopes remain ideal instruments for qualitative analysis
and for viewing a signal's waveform as a function of time.
These instruments are managed by a microprocessor and offer an AUTOSET
automatic adjustment function as well as alternate triggering.
OX 530
OX 803B
n Simple and economical
n Comprehensive analogue instrument
n Delayed time base and component
tester
Specifications
OX 530
Quick selection
Bandwidth
30/35 MHz
OX 803B
40 MHz
Number of channels
2
Safety according to IEC 61010
Input sensitivity
Operating modes
Class 1 - 300 V CAT II
5 mV to 20 V/div
1 mV to 20 V/div
CH1, CH2, ALT, CHOP auto, ADD, -CH2, XY
CH1, CH2, ALT, CHOP, ADD, -CH2, XY,
component test
1
1 + delay
Time base
Sweep speed
10 ns to 200 ms/div
Triggering
AUTOTEST function
Special features
Automatic and cursor measurements
Selection families
CH1, CH2, ALT, EXT, LINE
SMART AUTOSET
Saving of settings, check on user
choices by microprocessor,
display of selections by LED
-
Bandwidth
Component tests
-
Digital link
Power supply
94 - 264 V (48/440 Hz)
435 x 330 x 163 mm / 5.5 kg
Accessories supplied
1 mains power lead, 1 user manual (S version with 2 probes also available)
435 x 330 x 163 mm / 6.3 kg
Isolated single-channel cathode-ray training
oscilloscope
OX 71
n 5 MHz bandwidth
n 50 mV/div to 5 V/div sensitivity
in 1-2-5 sequence
n Sweep rate from 500 ns/div
to 500 ms/div
n IEC 61010-1 safety, class 2,
400 V CAT II
n Delivered with training software
in 5 languages
Standard state at delivery
References to order
1 OX, 1 mains power cable,
1 user manual
OX0530: OX 530 oscilloscope
OX0530-S: OX0530 + 2 probes
OX0803B: OX 803B oscilloscope
OX0803BS: OX0803B + 2 probes
OX71: single-channel 5 MHz training oscilloscope
Available accessories
56
See pages 110 to 118
40 to 100 MHz
100 and 300 MHz
2 / class 1 - metal
BNC
4/class 1 - metal
BNC
300 V CAT II
600 V CAT II
300 V CAT II
300 V CAT I
1 GS/s
2.5 GS/s
500 MS/s to 1 GS/s
2 GS/s
50 GS/s
100 GS/s
10 to 50 GS/s
10 bits
12 bits
8bits
8bits
•/•
•/•
•/-
•/•
Max. input sensitivity
2.5 mV/div
2.5 mV/div
2 mV/div
2 mV/div
Max. input amplitude
100 V/div
200 V/div
10 V/div
10 V/div
Time base (per division)
1 ns-200 s
1 ns-200 s
2.5 ns-50 s
1 ns - 50 s
2.5 or 50 k / channel
Up to 2 GB
on SD Card
50 kpts / channel
Up to 2 GB
on SD Card
40 kB / channel
Up to 2 MB
28 Mpts
20/•
20/•
32/•
32/•
8 bits
Channels (number/type)
Vertical resolution
PC communication via USB / Ethernet
"Oscilloscope" specifications
Memory depth
Acquisition memory
Other functions
FFT Lin & Log spectral analysis
10 bits / 60dB
12bits / 60dB
TRMS multimeters / Generator
200 kHz
200 kHz
Harmonic analyser
8 bits
25 MHz generator
61 orders
61 orders
-
Threshold recorders (number of channels)
2
4
Recorder
Power/power harmonics measurement
•
•
-
5.7 inches
5.7 inches
7 inches
8 inches
•
•
60-61
62-63
General specifications
LCD colour screen
Software calibration 100% "casing closed"
n AC, DC and earth coupling
DOX3104
DOX3304
200 MHz
Automatic measurements/Cursors
With its coloured buttons and safety banana plugs, the OX 71 is the product
of reference for training people how to use an oscilloscope. In terms of
safety, their double isolation prevents risks due to connection errors:
OXi6204
SPO
4 / isolated - plastic
BNC
Repetitive mode
Dimensions / Weight
Ox6202B
Ox6062B
Classic
DOX2025
DOX2040
DOX2100
60 to 200 MHz
One-shot digital sampling
RS232 available as an option
Expert
2 / class 1 - metal
BNC
IEC61010 safety
General specifications
Multi-purpose
ScopeNet PC web server/ANDROID app.
Pages
•/•
•/•
58-59
58-59
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
57
www.metrix.fr
digital OSCILLOSCOPES
digital OSCILLOSCOPES
• REC
2.5 kpts
50 kpts
Specifications
DMM
FFT
General-purpose digital oscilloscopes
OX 6062B, OX 6202B
& OXi 6204
4 modes in one instrument:
oscilloscope + multimeter + recorder + analyser.
n Backlit ¼ VGA colour TFT LCD
TOUCH screen
n Multi-interface communication:
RS232, USB, Centronics and
Ethernet
n High-capacity data storage on
removable SD-Card up to 2 GB
and more capacity on FTP server
n WEB server for "100 % of
functions", FTP server/client
for easy file exchange and
Instruments Administrator via
Ethernet on PC or Android tablet
The OXi 6204 proposes all the
functions of a 4-channel SCOPIX
with 4 x 600 V CAT II plastic BNC
terminals and 1 x RJ45 cable for
Ethernet connection.
Extension of storage capacity
As these instruments are equipped with micro SD cards, users can store all the data (reference curves, instrument settings, screenshots) up to 2 GB. The USB/SD card reader delivered
with the instrument makes data transfer onto PC quick and simple.
Standard state at delivery
References to order
1 OX 6000 oscilloscope , 1 stylus, 1 user manual and 1
programming manual on CD-Rom, 1 μSD card with a minimum
capacity of 1 GB plus SD adapter, 2 x 1/10 probes, 1 Ethernet
crossover cable and 1 USB / RS232 cable
OX6062B-CSD: Digital oscilloscope, 2 x 60 MHz, SD, colour
OX6062B-MSD: Digital oscilloscope, 2 x 60 MHz, SD, B&W
OX6062B-CSDO: Digital oscilloscope, 2 x 60 MHz, SD, colour with all
options installed
OX6062B-CFG: Digital oscilloscope, 2 x 60 MHz, SD, colour, with one
extra configurable option as selected
OX6202B-CSD: Digital oscilloscope, 2 x 200 MHz, SD, colour
OX6202B-CSDO: Digital oscilloscope, 2 x 200 MHz, SD, colour with
all options installed
OX6202B-CFG: Digital oscilloscope, 2 x 200 MHz, SD, with one extra
configurable option as selected
OXi6204: Digital oscilloscope, 4 x 200 MHz, SD, colour plus recorder
and 50 kpts options installed
OX6000B accessories
HX0003: 1/10 safety probe, 150 MHz, 400 V
HX0004: 1/10 safety probe, 250 MHz, 1,000 V
HX0210: 1/1 standard probe, 100 MHz, 300 V CAT II
HX0220: 1/1 standard probe, 200 MHz, 300 V CAT II
HX0077: 50 kpts memory option
HX0028: Harmonic analyser mode
HX0029: Recorder mode
OX 6062B
OX 6202B
OXi 6204
Human-Machine Interface
Display
Colour 1/4 VGA LCD (115 x 86 mm) - 320 x 240 – TFT backlighting (adjustable automatic power off)
On-screen display of curves
2/4 curves + 4 references
Commands
32 commands in direct access & shortcuts – 1 on-off and standby button
Touch screen – "Windows-like" menus and graphical commands
5 complete languages with menus & online help (English, French, Italian, Spanish and German)
Vertical
Bandwidth
60 MHz
200 MHz
15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
Number of channels
2 Class 1 channels (referenced to earth)
4 isolated channels
300 V CAT II - Metal BNC
600 V CAT II - Plastic BNC
Vertical sensitivity
Ranges from 2.5 mV to 100 V/div (± 2 %)
200 V/div
Vertical zoom
"One Click Winzoom" system
(graphical zoom directly on screen) – x 16 max.
Probe factors
1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit
Horizontal
Sweep speed
35 calibres from 1 ns/div to 200 s/div.- Roll mode from 100 ms to 200 s/div
Horizontal zoom
"One Click Winzoom" system (graphical zoom directly on screen) - x 5 max.
Triggering
Mode
Automatic, Triggered, One-shot, Auto Level 50 % / CH1, CH2, EXT, LINE
Edge, Pulse width (20 ns - 20 s), Delay (120 ns à 20 s), Counting,
TV frame or TV line (525 = NTSC or 625 = PAL/SECAM)
Continuous adjustment of Trigger position
Digital memory
Maximum sampling rate
50 GS/s in ETS mode
100 GS/s in ETS mode
1 GS/s in one-shot mode (on each channel)
2.5 GS/s in one-shot mode
Storage capacity: 2,500 pts per channel
(200 curves in memory) or 50 kpts
50 kpts
2 GB on SD card - 2 ns GLITCH mode / Envelope, Averaging (factors 2 to 64) / XY mode
Other functions
AUTOSET
Complete in less than 5 s, with recognition of the channels – Frequency > 30 Hz
FFT (Lin or Log) with measurement cursors - Functions: + , - , x , / with management of coefficients & units
Measurements: 2 or 3 cursors & 20 automatic measurements – Resolution 10/12 bits, 4-digit display
Multimeter
Channels / counts
2 channels / 4,000 cts
4 channels / 8,000 cts
Min/max bargraph – TRMS
Time/date-stamped graphical recording (5 min to 31 days)
AC, DC, AC + DC voltages
300 to 300 Vrms or 400 Vdc
300 mV to 600 Vrms
or 600 Vdc
Vdc accuracy 0.5 %R +5 D – bandwidth 200 kHz
Resistance80 Ω to 32 MΩ – accuracy 0.5 %R + 5 D – quick continuity test < 10 ms
Other measurements
Capacitance: 5 nF to 5 mF / Frequency: 200 kHz / 3.3 V diode test
Harmonic analyser mode (option)
2/4 multi-channel analysis, 61 orders, fundamental frequency from 40 to 450 Hz in auto or manual mode
Simultaneous measurements: total Vrms, THD and selected order
(% fundamental, phase, frequency, Vrms)
Recorder mode (option)
Integrated
Duration / Sampling from 2 s to 1 month / 800 µs to 18 min.
(40 μs to 53 s with "Extended Memory" option,
recording conditions on thresholds or window,
simultaneous conditions on several channels, with adjustable duration from 160 μs,
analysis of recordings, scale and physical units, automatic or cursor measurements,
time/date-stamped fault search function, zoom, etc.
General specifications
Network screen printing (standard), 11 B&W or colour drivers : IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411,
Postscript Image files: ".bmp" approx. 10 kB, ".gif" approx. 5 kB
RS232 (standard) or Centronics (optional accessory)
(storage in memory, RS232 or Ethernet transfer)
PC communication
Local Ethernet, RS 232 (max. 115 kbs) or USB (option)
Remote Ethernet 10 Mb and ScopeNet web server
"SX-Metro" PC application software (option)
Mains power supply
Adjustable standby mode
Multi-voltage: 98-264 V / 47-63 Hz / < 15 W - Removable cable
Mechanical specifications
230 (h) x 185 (l) x 180 (w) mm / 2.1 kg
Warranty
Lifetime warranty
OXi6204 accessories
58
OX 6062B - OX 6202B
OscillOscOpes - AnAlyseurs
HX0108: 600 V safety probe + 600 V BAN/BNC adapter
HX0106: BNC-BNC lead 1 m 600 V (x2)
HX0107: BNC-BAN adapters 4 mm 600 V (x2)
et Enregistreurs – 60 et 200 MHz
2
GÉNÉRATION
complets
toujours plus
Available accessories
See pages 110 to 118
Des oscilloscopes multi-fonctions,
avec écran tactile 5,7", dans un encombrement minimal !
● Mémoire étendue 50 kpoints
● 4 outils complémentaires en un, pour une compacité et une efficacité record :
OSCILLOSCOPE-MULTIMÈTRE-ENREGISTREUR-ANALYSEUR FFT et HARMONIQUES
● Vitesse d’échantillonnage : 1 Gé/s en Monocoup et 50 Gé/s en ETS
● 2 voies de mesure 300 V - Cat. II, 10 bits de résolution
● Analyse FFT “ temps réel ” standard et fonctions de calcul sur les voies simples et complexes
● 2 multimètres numériques, TRMS, 4 000 points, 200 kHz avec enregistrement graphique horodaté
● 28 touches de commande directe, menus “ Windows-like ” et commandes graphiques (écran tactile)
● Communicant multi-interfaces :
RS232, USB et Ethernet avec serveur Web SCOPENET intégré
● Compatible Android™
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
● Support de stockage amovible carte micro-SD jusqu’à 2 Go
● 2 analyseurs harmoniques THD jusqu’au rang 61 sur fondamentale de 40 à 450 Hz
For further details…
● 2 enregistreurs, durée et fréquence d’échantillonnage variable
59
BENCHTOP DIGITAL OSCILLOSCOPES
2-channel colour digital
oscilloscopes
BENCHTOP DIGITAL OSCILLOSCOPES
Specifications
FFT
• REC
Math
2 Mpts
Type of display
Display of curves on screen
DOX 2000 family
DOX 2025
DOX 2040 / DOX 2100
Human-Machine Interface
Commands
7" colour TFT LCD screen (resolution 480 x 234) / Adjustable brightness and contrast
8 x 18 division trace area / 2 curves + reference + Math function - Complete graticule or borders
Display mode: Samples or Vectors with interpolation or Persistence Mode
Usual direct commands via buttons on front panel / System with menus on right-hand side of screen
with selection using 5 buttons opposite – "Menus On/Off" and print commands
Choice of language
By menu, 5 languages (FR/EN/DE/IT/ES), online help in English
Vertical deflection
Bandwidth
Number of channels
2 channels, common chassis-earths
Impedance
1 MΩ / 18 pF and External Trig channel
Display of traces
Channel number, earth reference indicator and trace in the colour of the channel
Maximum input voltage
± 300 Vp-p (without probe)
Vertical sensitivity
12 calibres from 2 mV to 10 V/div - Basic accuracy ±3 %
Rise time
< 14 ns
Compensated probe factors
Exceptional ergonomics: extra-bright 7" TFT colour screen
• Customization of the display to suit your needs: normal or persistent display, YT or XY format, screen
types with adjustable colours, graticule, brightness, contrast, etc.
• Simple front panel: traditional front-panel controls (rotary knobs and keys)
• 5 language choices selectable per menu (English, French, Spanish, Italian, German)
• Quick power-up and power-down in less than 10 s
• Easy to transport due to its shape, its built-in handle and its 9-inch depth
High performance and multiple
acquisition and analysis functions
• Maximum sampling rate of up to 1 GS/s in oneshot mode and 50 GS/s for periodic signals
• Acquisition memory depth from 32 kpoints to
2 Mpoints, depending on the model, to optimize
your analyses
• 5 complete trigger types: edge, pulse, video,
slope and alternate
• 32 simultaneous automatic measurements on
screen and manual cursor measurements
• Recording of up to 6 Mpoints by slow acquisition
Horizontal deflection
Sweep speed
Scan or ROLL mode
Horizontal zoom
Triggering
Sources / Modes
Roll mode
Type
Coupling
Digital data storage
Maximum sampling rate
Practical interfaces and printing
Vertical resolution
• Usual communication: USB host and device (PC,
Pictbridge printer, USB key)
• Multiple storage: 20 configurations and 5 types
of recordings: parameters, curves, images, .csv
and factory settings internally or on USB key, etc.
• Comprehensive EASYSCOPE software for all
your analyses
Memory depth
25 ns/div. to 50 s/div. (Oscilloscope mode)
2.5 ns/div. to 50 s/div. (Oscilloscope mode)
100 ms/div. to 50 s/div. (Recorder - Scan mode)
Yes
CH1, CH2, Ext, Ext/5, mains / Automatic, Triggered, One-shot- XY
100 ms/div. to 50 s/div.
Edge, pulse width (20 ns - 10 s), video (Pal, Secam, NTSC), slope, alternate
AC, DC, HFR (HF rejection), LFR (LF rejection)
One-shot = 250 MS/s (2 channels), 500 MS/s (1 channel)
Repetitive = 10 GS/s
One-shot = 500 MS/s (2 channels), 1 GS/s (1 channel)
Repetitive = 50 GS/s
8 bits (vertical resolution 0.4%)
Max. depth = 32 kpoints
"Unlimited" storage capacity (USB key)
Max. depth = 2 Mpoints (long MEM)
"Unlimited" storage capacity (USB key)
2 MB for storing trace, text and configuration files, math functions,
print files, image files, etc.
Trace files (proprietary format and .CSV format compatible with spreadsheets for the signals /
Complete instrument setup files / Screenshot files (.BMP format compatible with Windows)
PEAK DETECT mode
(transient capture)
Minimum event duration = 10 ns
Points or vectors
Persistence (1s, 2s, 5s, 10s.20s or infinite) or Averaging (factor from 4 to 256)
Display modes
XY mode
Yes
Other functions
AUTOSET
MATH functions on the channels
FFT analyser
AUTO-adjustment of amplitude, time base and trigger position
Trace calculated in "real time": CH1 and CH2: addition, subtraction, multiplication, division
FFT calculated over 1,024 points / Simultaneous display of trace + FFT / 4 window types (Rectangle,
Hamming, Hanning, Blackmann)
Manual measurement cursors
PASS/FAIL
Recorder
Automatic measurements
Probe calibration signal
Warranty
Easyscope software for data processing (csv), SCPI command transmission, screenshots (bmp), configuration, virtual control panel
60
< 8 ns (DOX2040) <3.5 ns (DOX2100)
1 / 5 / 10 / 50 / 100 / 500 / 1,000
User memory
File management
40 MHz / 100 MHz
20 MHz bandwidth limiter
25 MHz
Recording mode for slow signals > 100 ms (6 Mpoint ROLL)
32 time or level measurements
Yes
3 years
Standard state at delivery
References to order
1 DOX digital analyser-oscilloscope,
European mains power cable, 2 x 1/1
and 1/10 switchable voltage probes,
USB A/B cable, CD-ROM containing PC
software and user manual
DOX2025: Digital oscilloscope 2 x 25 MHz
DOX2040: Digital oscilloscope 2 x 40 MHz
DOX2100: Digital oscilloscope 2 x 100 MHz
Available accessories
Simple MATH functions +/-/*/ and "real-time" FFT
function with simultaneous display of trace
Detailed product brochures can be downloaded free of charge from www.metrix.fr
Manual, tracking and automatic modes
Pass/Fail test on the basis of a limit envelope
See pages 110 to 118
www.metrix.fr
61
For further details…
SPO BENCHTOP DIGITAL oscilloscopes
SPO BENCHTOP DIGITAL oscilloscopes
28 Mpts
FFT
Math
Specifications
DOX 3000 family
Comprehensive with high performance
100 and 300 MHz bandwidth
with built-in 25 MHz generator
and serial bus decoding
4-channel oscilloscopes with TFT screen 8 inches
wide offering 256 levels of colour intensity.
Display using Sensitive Phosphor Oscilloscope
technology for optimized waveform capture:
110,000 wfs/s, exceptional acquisition and display
functions for precisely reconstructing a signal.
Maximum acquisition memory depth: 28 Mpoints.
Practical, intuitive HMI with tradition frontpanel commands (rotary knobs with lighting),
5 languages selectable by menu (English, French,
Spanish, Italian and German) plus help in French
and English.
High-performance oscilloscope with maximum
sampling rate of up to 2 GS/s in real time, vertical
sensitivity from 2 mV/div. to 10 V/div. and from 1 ns
to 50 s/div with complex and complete triggers
(Pattern, windows, interval, Dropout, runt).
A built-in 25 MHz arbitrary signal generator with
programming software is included.
Serial bus decoding function with integrated
triggers: I2C, SPI, UART, CAN, LIN and MSO
8-channel digital logic analyser for analysing
digital transmissions (DOX-MSO3LA option).
Easy analysis with 32 automatic measurements and
statistical chart, manual cursor measurements and
advanced math functions: simultaneous display of
trace + 4-channel FFT.
Communication: USB host, USB key and device
(PC, Pictbridge printers) and Ethernet.
Interface
Screen
On-screen display
Language
Vertical deflection
Bandwidth
No. of channels
Max. input voltage
Vertical sensitivity
Rise time
Probe compensation factors
Horizontal deflection Time base speed
Max. no. of traces captured per second
Horizontal zoom
Automatic ROLL mode Trigger system
Sources/Mode
Type
Trigger on serial bus and Decoding
MSO logic analyser input Acquisition
Real-time sampling rate
Vertical resolution
Acquisition depth
File manager
Acquisition
Peak detection
"Statistics" mode
Other functions
AUTOSET
MATH function FFT analyser Cursors
PASS/FAIL
Automatic measurements
Built-in 25 MHz function generator
DOX 3104DOX 3304
Colour 8" TFT LCD screen, 800 x 480 pixels, 24 bits
On 8x14 div with 4 channels + reference + Math functions and statistics table – full screen
Vector or point modes with interpolation, permanent SPO mode: normal or colour
French, English, Italian, Spanish and German
100 MHz / 300 MHz - Bandwidth limiter: 20 MHz
4 channels + 1 external channel
300 V (DC+AC Pk)
12 calibres from 2 mV to 10 V/div – Accuracy ±3% – 8-bit resolution
< 3.5 ns (DOX 3104) / < 1.2 ns (DOX 3304)
x 0.1 / 0.2 / 0.5 / 1 / 5 / 10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000
1 ns/div to 50s/div (oscilloscope)
110,000 traces/s
Compression, expansion
100 ms/div to 50 s/div (1-2-5 step)
CH1, CH2 or CH3, CH4 Ext, Ext/5, AC line / Auto, Normal triggered, One-shot
Edge, Pulse (20 ns to 10 s), Slope (rising, falling), Video (NTSC, PAL, SECAM),
Windows, Interval, Dropout, Runt, Pattern
I2C, SPI, UART/RS232, CAN, LIN
Option: 8 channels + clock for TTL/CMOS/LVCOM/CUSTOM signals
ETS: 2 GS/s
8 bits (vertical resolution 0.4%)
Up to 28 M: 14 Mpts per channel, adjustable: 7 k / 14 k / 70 k / 140 k / 700 k / 1.4 M / 7 Mpts
Trace files (DAV proprietary format and Excel-compatible ".CSV" format)
".set" configuration files – ".bmp" screenshot files
Normal, Peak detect, Average, High res.
Minimum event duration = 10 ns
Measurement of events
AUTO adjustment: amplitude, time base and trigger
Trace calculated in real time: CH1, CH2, CH3, CH4, + , - , x , / , (d/dt), integral (∫dt) and square root (√).
FFT calculated on 1,024 points - simultaneously with the waveform for the 4 channels
Adjustable windowing: rectangular, Hamming, Hanning, Blackmann
Manual, Track mode and Auto
Pass/Fail mode with specific terminal for envelope adjustment
32 measurements and statistics table
25 MHz- 125 MS/s - 14 bits - arbitrary function generation with EasyWave
General specifications
Recording
Printing
Communication on PC
Power supply
Safety / EMC / Locking
Temperature
Mechanical specifications
Internal storage or USB flash drive on front panel
Via USB Host (PictBridge)
Via USB device or Ethernet link for EASYSCOPE (OX) and EASYWAVE (GX) software
Universal 100-240 V / 45-440 Hz/ 50 VAmax with removable cable
Compliant with the IEC 6101-1 standard, 300V CAT I - EMC as per EN61326-1 - Kensington lock
Use: 0°C to +40°C - Storage: -20°C to +60°C
352 x 111 x 224 mm – 3.6 kg (4 channels) – IP20
3-year warranty
Standard state at delivery
References to order
1 DOX digital oscilloscope, European
mains power cable, 4 x 1/10 voltage
probes, 1 USB cable, USB key containing
software, user manual and practical
training exercises
DOX3304 (300 MHz, 4 channels) + arbitrary
generator+ serial bus decoding
DOX3104 (100 MHz, 4 channels) + arbitrary
generator + serial bus decoding
DOX-MSO3LA: MSO 8-channel logic probe
DOX3104 - DOX3304
Oscilloscopes numériques de table
4 voies 100 & 300 MHz
Available accessories
See pages 110 to 118
62
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
DOX3000
Oscilloscopes
Hautes performances
Décodeur de bus &
Générateur de signaux
arbitraires
For further details…
e
Afficheur 8¨ à Technologie Sensitive Phosphore Oscilloscope pour capture de formes d’onde optimisée :
110 000 wfs/s
e
e
e
e
Profondeur mémoire d’acquisition 28 Mpoints
e
Facilité d’analyse avec 32 mesures automatiques, tableau de statistiques, mesures par curseurs manuels,
fonctions mathématiques avancées
Fonction de décodage de bus série avec déclenchements intégrés : I2C, SPI, UART, CAN, LIN
Générateur arbitraire 25 MHz intégré avec logiciel de programmation inclus
Hautes performances avec échantillonnage maximum jusqu’à 2 Gé/s en temps réel, sensibilité verticale de
2 mV/div. à 10 V/div. et de 1 ns à 50 s/div avec triggers complexes et complets
(Pattern, windows, interval, Dropout, runt)
IEC 61010
300 V CAT I
63
ON-SITE DIGITAL oscilloscopes
ON-SITE DIGITAL oscilloscopes
SOFTWARE for the DOX family of BENCHTOP
OSCILLOSCOPES
EASYSCOPEX is the PC data processing software for
the oscilloscopes in the DOX family.
It can be used to extend the oscilloscope's functions
via USB (without drivers) or Ethernet (DOX 3000),
depending on the models, for:
• Recovery of the .csv trace files
• Transmission of programming commands (SCPI
format)
• Remote command test via VIRTUAL PANEL
• Recovery of screenshots in .bmp format
Selection guide
"Stand-alone" multi-function oscilloscopes
Handscope
Selection families
Transmission of SCPI commands
Bandwidth
Scopix
Maintenance
Electronics
Energy
Industrial
Fieldbus
OX5022
OX5042
Ox7202-Ox7204
Ox7102-Ox7104
Ox7062
Ox7104P
Ox7042P
Ox7042
OX7202 BUS
OX7204 BUS
20 and 40 MHZ
60 to 200 MHz
40 to 100 MHz
40 MHz
200 MHz
2 isolated
2 or 4 / isolated
2 or 4 / isolated
2 / isolated
2 or 4 / isolated
50 MS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
2.5 GS/s
Repetitive mode
2 GS/s
50 or 100 GS/s
50 or 100 GS/s
50 or 100 GS/s
50 GS/s
Vertical resolution
9 bits
12 bits
12 bits
12 bits
12 bits
> 20 ns
2 ns
2 ns
2 ns
2 ns
•/•
•/•
•/•
•/•
•/•
•
•/•
•/•
•/•
•/•
•
•
•
•
Mains/battery power supply
•/•
•/•
•/•
•/•
•/•
Alimentation secteur / Batterie
•/•
•/•
•/•
•/•
•/•
Max. input sensitivity
5 mVdiv
156 µV/div
156 µV/div
156 µV/div
156 µV/div
Max. input amplitude
200 V/div
200 V/div
200 V/div
200 V/div
200 V/div
1.5 MHz, 5 kHz
15 MHz, 1.5 MHz,
5 kHz
15 MHz, 1.5 MHz,
5 kHz
15 MHz, 1.5 MHz,
5 kHz
15 MHz, 1.5 MHz,
5 kHz
Time base (per division)
25 ns-200 s
1 ns-200 s
1 ns-200 s
1 ns-200 s
1 ns-200 s
Roll mode / XY mode
•/•
•/•
2.5 to 50 k /
channel
Up to 2 GB on
SD card
•/•
2.5 to 50 k /
channel
Up to 2 GB on
SD card
•/•
2.5 to 50 k /
channel
Up to 2 GB on
SD card
•/•
Channels (number/type)
IEC61010 safety
One-shot digital sampling
Transient detection (Glitch)
Scaling/physical unit
PC communication / Ethernet
1000 V CAT II / 600 V CAT III
Ethernet 10Mb + Web server
Screenshots
"Oscilloscope" specifications
Analogue filter
vailable at the rear of the
A
instrument:
n Input channel for the Pass/
Fail mask test, ideal for quickly
identifying problems on a signal
n Input channel for external
triggering
Recovery of traces
"Memory depth
2.5 k / channel
Acquisition memory"
2 MB memory
Up to 2 GB on
SD card
No. of reference or math curves on screen
n PC/device communication
interfaces: USB or Ethernet
Envelope / Averaging modes
SPO (Smart Persistence Oscilloscope)
n Slot for KENSINGTON lock for
greater security
EASYWAVE is PC software which allows users to:
• Recover the curves from the oscilloscope mode and
then modify the waveforms using drawing tools
• Transfer or import waveforms into the ARBitrary
Automatic measurements / Cursors
-
•/•
•/•
•/•
•/•
Pulse trigger width/number
-
•
•
•
•
Video trigger (line counter)
-
•
•
•
•
Trigger on measurement & automatic backup
-
•/•
•/•
•/•
•/•
Adjustable Hold-Off / Delay
Virtual panel
•/•/•
•/•/•/•
•/•/•/•
•/•/•/•
•/•/•/•
Advanced + - / x / : / calculation functions
•
•
•
•
•
Autoset with channel selection
•
•
•
•
•
Other functions
FFT Lin & Log spectral analysis
function (4 memory locations)
• Consult the file library (sine, square, ramp, pulse,
noise, cardiac, exponential, etc.) in the memory of
the oscilloscope's generator mode
-
12 bits / 72 dB
12 bits / 72 dB
12 bits / 72 dB
12 bits / 72 dB
TRMS multimeters
50 kHz
200 kHz
200 kHz
200 kHz
200 kHz
Harmonic analysis
31 orders
61 orders
61 orders
61 orders
Threshold recorders (no. of channels)
2
2 or 4
2 or 4
2
Power/Power Harmonics measurement
•
•
•
•
•/-/-
•/-/-
•/-/-
•/•/-
•
•
•
•
•
•/•
•/•
•/•
•except bus /•
68-69-71
68 to 70
68-70
72
2 or 4
General specifications
Colour LCD / B&W / Tube screen
100% "casing closed" software calibration
Creation of waveforms
ScopeNet PC web server / ANDROID app
64
50 k / channel
These software products are available from the DOX Support section on our website.
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Pages
66-67
•/•/-
65
oscilloscopes WITH ISOLATED CHANNELS
DMM
oscilloscopes WITH ISOLATED CHANNELS
W
2.5 kpts
Stand-alone portable digital oscilloscopes
OX 5022 & OX 5042
The most compact oscilloscopes with totally isolated channels on the
market for all your work on electrical installations in the field as well as for
general maintenance.
Performance
n 4 in 1
- 20 or 40 MHz oscilloscope
- Double 8,000-count multimeter
- Harmonic analyser
- Power analyser
- Advanced mathematical functions with automatic
scaling and complex triggers
Ergonomics
n 3.5" colour TFT screen with LED backlighting
and 320 x 240 resolution
n Simple to use: one key equals one function
(triggering, configuration, etc.)
n Integrated interactive multilingual help function
n Recording of the measurements
n Isolated USB communication using the SCPI protocol
Specifications
Quick selection
Bandwidth
Bandwidth limiter
Number of channels
IEC 61010 safety
Maximum sampling rate
Vertical resolution
Display mode
Digital oscilloscope
Vertical sensitivity
Sweep speed Data storage
Display of curves on screen
Automatic measurements
Triggering
TRMS multimeter
Specifications Recording
Measurement functions
Power
Harmonic analyser
Multi-channel analysis
Simultaneous measurements
General specifications
PC communication
Power supply
Mechanical specifications
Warranty
OX 5022OX 5042
20 MHz
40 MHz
1.5 MHz, 5 kHz
2 totally-isolated channels
600 V CAT III
2 GS/s in ETS mode – 50 MS/s in one-shot mode on each channel
9 bits
2,500 real acquisition points on screen
Envelope, Averaging (factors 2 to 64) and XY (vector)
5 mV to 200 V/div
25 ns/div to 200 s/div –Roll Mode from 100 ms to 200 s/div
Memory depth: 2,500 points per channel
2 MB for storing files: trace (.trc), text, (.txt), configuration
(.cfg) and image files (.bmp)
2 curves + 2 references + memory trace or mathematical calculation
18 time or level measurements and phase measurement
2 cursors: V, T, dV, dt simultaneously –4-digit display resolution
Automatic, triggered, one-shot & triggered Roll on Edge or Pulse Width (20 ns – 20 s)
2 channels, 8,000-count display + min/max bargraph
Graphic recording of 2,700 measurements (5 min to 1 month)
AC, DC and AC+DC voltages, resistance, continuity, capacitance, frequency, rotation speed,
3.3 V diode test, temperature measurement (with K thermocouple or infrared probe)
Single-phase and balanced three-phase active power values
(with or without neutral), simultaneous display of current
2 channels, 31 orders, fundamental frequency from 40 to 450 Hz
Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
Isolated optical USB interface –"SX-Metro" PC application software supplied
6 x LR6 batteries or 6 AA NiMh batteries – Battery life up to 8 hrs 30 min
Universal mains adapter isolated from the channels – Quick charging in 3 hours
214 x 110 x 57 mm – 1.2 kg with batteries
moulded elastomer casing, IP54 protection
3 years
Communication and software
HANDSCOPE oscilloscopes communicate with PCs
via an isolated optical USB interface.
The SX-Metro data processing software,
supplied as standard, can be used to:
n View the curves from stored files
n Display the curves on the PC in real time
n Control the oscilloscope via the PC
n Import curves stored in the oscilloscope's memory
or "image" files
n Store curves in text format on the PC
Standard state at delivery
Accessories and replacement parts
Version C: 1 oscilloscope delivered with 1 x 1/10 600 V probe,
1 BNC/Banana adapter, 1 set of banana leads, 1 mains adapter,
1 set of 6 x AA NiMh batteries, 1 hands-free bag, 1 CD-Rom
containing 1 user manual and 1 programming manual.
20 A AC/DC - 100 mV/A current clamp . . . . . . . . . . . . . . . . . . . . . . . . . HX0102
C.A 1871 infrared temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . P01651610Z
C.A 801 simple thermocouple adapter . . . . . . . . . . . . . . . . . . . . . P01652401Z
C.A 803 differential thermocouple adapter . . . . . . . . . . . . . P01652411Z
C.A 1711 tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01102082
Version CK: 1 oscilloscope delivered with 1 x 1/10 600 V probe,
1 BNC/Banana adapter, 1 set of banana leads, 1 isolated
optical USB communication cable, 1 mains adapter, 1 set of
6 x AA NiMh batteries, 1 hands-free bag, 1 CD-Rom containing
1 user manual, 1 programming manual, the drivers for the
optical USB cables and the SX-Metro PC software.
References to order
OX5022-C: 1 oscilloscope 2 x 20 MHz
OX5022-CK: 1 oscilloscope 2 x 20 MHz + USB communication
OX5042-C: 1 oscilloscope 2 x 420 MHz
OX5042-CK: 1 oscilloscope 2 x 40 MHz + USB communication
n Transfer the data or the curves into Excel
66
Available accessories
www.handscope.chauvin-arnoux.com
Detailed product brochures can be downloaded free of charge from www.metrix.fr
See pages 110 to 118
www.metrix.fr
67
For further details…
oscilloscopes WITH ISOLATED CHANNELS
• REC
DMM
FFT
oscilloscopes WITH ISOLATED CHANNELS
W
50 kpts
The Scopix range
6 modes to cover all the domains
from 40 to 200 MHz
Performance
n 5 instruments in 1! All the Scopix
models are simultaneously
oscilloscopes, multimeters, FFT
analysers, harmonic analysers and
loggers
n Bandwidth from 40 to 200 MHz
Universal
communication
n Multiple interfaces: RS232, USB,
Ethernet
n Removable microSD card for largecapacity data storage and transfer
n 2 or 4 isolated channels
n ScopeNet with cursors and
automatic measurements
Ergonomics
n FTP server/client and Instrument
Administrator on Ethernet
n Monochrome LCD or colour TFT
touch screen with LED backlighting
n Traditional control interface:
33 direct command keys
n Control by "Windows-like" menus
or graphical objects on the touch
screen.
The familiar "Windows-like'
environment is simple to learn and
use. On the touch screen, users can
access all the functions with the
stylus via the drop-down menus and
can act on the graphical elements
(cursors, triggers, etc.).
The PROBIX® "Plug &
Play" system for safe,
simple use
n Automatic recognition of the
sensor type and the associated
measurement
The extensive functions of the
SCOPIX family make it ideal for the
requirements in several sectors of
activity:
n In the industrial maintenance
sector, the OX 7042 and OX 7104
are designed for maintenance
technicians (see details of functions
on page 70)
n In the Energy sector, the OX 7042P
and OX 7104P are available in
"Power" versions with special
accessories and application
modules
n In Electronics, the OX 7062, OX
7102, OX 7104, OX 7202 and
OX 7204 have all the features
necessary to meet the needs of
technicians and engineers involved
in the design, commissioning or
maintenance of equipment (see
details of functions on page 71)
n Accessories powered by the
instrument
Specifications
OX 7042 OX 7062 OX 7102
OX 7104 OX 7202
OX 7204
Quick selection
Bandwidth 40 MHz
60 MHz
100 MHz
100 MHz
200 MHz
200 MHz
15 MHz, 1,5 MHz and 5 kHz bandwidth limiter filters
Number and type of channels
2 isolated channels
4 isolated channels 2 isolated channels 4 isolated channels
IEC 61010 safety 600 V CAT III
2.5 GS/s in one-shot mode, 100 GS/s for periodic signals
Sampling rate per channel
Transient detection
"Glitch" capture, minimum duration 2 ns
Vertical resolution
12 bits, giving a vertical resolution of 0.025 %
Display modes
Vector, interpolation, persistence, envelope, averaging (factors 2 to 64)
Scaling and physical units
Definition of any factor and the corresponding unit
Digital oscilloscope
Input sensitivity
2.5 mV to 200 V/div (156 μV max. with zoom thanks to the 12-bit resolution)
Time base
1 ns to 200 s/div, Roll mode from 100 ms to 200 s/div
Data storage
Several tens of thousands of 2,500-point curves (in universal "text" format)
Memory depth up to 50 k – Mass storage on removable SD card up to 2 GB
Reference curves on screen
1 per active channel (1 to 4) / Direct storage with dedicated key
Automatic measurements
20 simultaneous measurements on curves or deviations from the reference curve – 12-bit resolution
with marker
Triggering
Edge, pulse width, delay, counting, video with line counter
and on one of the 20 automatic measurements
FFT on 2,048 points, +, -, x, /, and complex function generator
Calculation functions on channels
TRMS multimeter (AC, AC+DC)
Measurement channels
2 isolated channels
4 isolated channels2 isolated channels 4 isolated channels
with 200 kHz bandwidth
Measurement functions
Voltage, current, frequency, capacitance, temperature (Pt 100, K TC),
diode test and audible continuity test, relative mode, min/max mode
Graph of measurements with cursors
Duration from 5 min to 31 days, data storage in "universal text" format
Triggering on threshold checks
Harmonic analyser*
Multi-channel analysis
61 orders, fundamental frequency from 40 Hz to 450 Hz
(2 or 4 depending on model)
Simultaneous measurements
Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
12-bit digital recorder*
Multi-channel recording
Duration from 2 s to 31 days, normal mode or automatic fault capture mode with pre-trigger
Sampling interval from 40 μs (50 k memory)
Recording conditions
On thresholds or windows, simultaneous conditions on several channels
Recording (50,000 points) on the PC hard disk or SD card
Analysis of recordings
Scale and physical units, measurement by cursors, fault detection, zoom, etc.
Power measurement*
Measurement functions
Active, reactive and apparent power, on single-phase or three-phase, and PF
Harmonics
Harmonic analysis on apparent power
General specifications
"Windows-like" operator interface
B&W or colour*
Colour
Simultaneous display of traces
Up to 4 traces + 4 references on screen / "Full screen" trace mode
PC communication and printing
RS232*, isolated USB* or Ethernet 10 Mb / Network or Centronics* printers
FTP mode to use the PC hard disk as a storage unit
Virtual Printer server LPD for printing on a printer connected to a PC
Web server with real-time display, remote control and automatic measurements
Power supply by rechargeable
Battery life up to 8 hrs, quick charging in 2 hrs without removing the batteries
battery
* Depending on models or option
n Automatic scaling and
measurement units
The Ethernet interface and SCOPENET can
be used with a PC to control and view all the
SCOPIX models by means of their IP address
and a simple browser. An ANDROID application for tablets and smartphones can also be
downloaded from Google PLAY.
www.chauvin-arnoux.com/scopix
68
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
69
oscilloscopes WITH ISOLATED CHANNELS
oscilloscopes WITH ISOLATED CHANNELS
Scopix Industrial Maintenance
Scopix Electronics
OX 7042 & OX 7104
OX 7062, OX 7102,
OX 7104, OX 7202 & OX 7204
2 models equipped with a broad range of functions for acquiring and recording anomalies
n Bandwidth: 40 or 100 MHz
n 2 or 4 isolated channels, 600 V Cat III safety (1,000 V with the HX0030B probe or the HX0095 adapter)
n Colour or monochrome screen
For the Oscilloscope, Recorder and Multimeter modes, it is possible to capture faults by setting a software trigger based on
monitoring of the tolerance interval qualified by a duration.
Oscilloscope mode:
capture on automatic measurements
Users have access to
20 different
automatic
20 automatic measuremeasurements
ments in this mode.
Once the required measurements have been
selected, all you have
to do is set the trigger
thresholds and activate
fault capture.
Storage and automatic reactivation of
acquisitions on threshold overruns (AUTO,
NORMAL, SINGLE or ROLL)
Mains monitoring or surveillance
mode on up to 4 channels in multimeter mode
If the RMS value of the signal reaches
the min or max levels, defined on each
channel, the event is recorded and
dated in a list of faults; this list can be
saved in a file.
Recorder mode: fault capture
To monitor the variations of physical
or mechanical
phenomena over
time, there is a
software module
available to integrate a genuine
70
fast digital recorder into the instrument.
It offers acquisition intervals as short as
40 μs between 2 measurements and the
recordings may cover any period from 2
seconds to one month.
Automatic fault capture can be performed by monitoring 1 or 2 thresholds per
channel. The fault duration can be set
from 160 μs to approximately 8 days. This
type of monitoring can also be performed
on tolerance windows. Capture triggers
storage of the phenomenon observed in
non-volatile memory (up to 50 kpoints)
or automatic acquisition of successive
time/date-stamped faults (max. 500
faults). The faults recorded automatically are stored either in the instrument's
internal memory or on an FTP server (PC
hard disk).
harmonic order is greater than the level
of the fundamental.
It is possible to view the harmonic analyses of two or four channels simultaneously
Multimeter mode:
monitoring of measurements
Fault capture is performed by monitoring 1 or 2 thresholds per channel. The
fault duration can be set from 48 ms to
approximately 8 days. All the faults captured (several thousand can be stored
on the SD card) can be recalled by using
the Scopix menus. The list of time/datestamped faults indicates the source and
the result of the measurement. This list
can be saved in ".txt" format.
Harmonic Analyser mode
Harmonic analysis is performed up to
the 61st order (THD on a minimum of 50
orders), with a fundamental frequency
between 40 and 450 Hz. It is possible to
preselect the frequency of the fundamental for the standards (50 Hz, 60 Hz and
400 Hz). This function helps to improve
analytical performance and above all
allows measurement when the level of a
HX0033, HX0030B
Probix/banana adapter,
1/10 voltage probe
- 250 MHz
The 5 models in this range are ideal for the needs of the electronics
sector, from PCB design to the development of complex systems.
n 156 μV / div input sensitivity for studying signals with very low
amplitudes
n Bandwidth of 60 to 200 MHz
n 2 to 4 isolated channels
A high-performance instrument
n Sampling rate of 2.5 GS/s per channel in one-shot mode and 100 GS/s in
repetitive mode.
n 12-bit converter providing a vertical resolution which is 16 times greater
than the resolution offered by the conventional 8-bit oscilloscopes on
the market.
n Isolated channels for simultaneous measurements without signal
constraints and with different chassis-earth references for very low
sensitivities and for signals up to 1,000 Vdc or rms.
n 2 MB internal memory, up to 2 GB of data on SD Card and direct storage
on PC hard disk via Ethernet (FTP Server/Client)
2 or 4 independent 200 kHz TRMS digital multimeters
Just as for the 4 "instrument" modes, a single press on the
dedicated key gives access to the multimeter. These 2 or 4-channel
TRMS digital multimeters can be used for the following
measurements:
n amplitude (DC or AC voltage or current, power, temperature, etc.)
n resistance, continuity and capacitance
n junction or diode tests, etc.
Pt 100 sensors or K thermocouples can be used for temperature
measurement.
The associated recorder can be used to monitor and save any changes in
the measurements over periods of 5 minutes to 1 month
Standard state at delivery
State at delivery for "CSDO models"
Same as "standard" plus 2 x 1/10 Probix probes, Harmonics, Recorder and 50 kb
options installed, SX-METRO-P software and a hard case
Standard state at delivery
References to order
1 OX oscilloscope, 1 mains adapter/charger, 1 NiMH 9.6 V –
3.8 A/h battery pack, 1 x 1/10 Probix probe, 1 banana Probix
adapter, 1 set of banana leads, 1 Ethernet crossover cable,
1 USB cable, 1 μSD card with SD-card adapter, 1 magnetic stylus,
1 operating and programming manual
OX7042-MSD: Oscilloscope, monochrome screen, 2 x 40 MHz
OX7042-CSD: Oscilloscope, colour screen, 2 x 40 MHz
OX7104-CSD: Oscilloscope, colour screen, 2 x 100 MHz
1 OX oscilloscope, 1 mains adapter/
charger, 1 NiMH 9.6 V-3.8 A/h battery
pack, 1 x 1/10 Probix probe, 1 banana
Probix adapter, 1 set of banana leads,
1 Ethernet crossover cable, 1 USB
cable,1 μSD-card with SD-card adapter,
1 magnetic stylus, 1 operating and
programming manual
Available accessories
Available accessories
See pages 110 to 118
See pages 110 to 118
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
FFT with a Hanning window
and a logarithmic scale
References to order
OX7062-CSD: 2 x 60 MHz oscilloscope
OX7102-CSD: 2 x 100 MHz oscilloscope
OX7104-CSD: 4 x 100 MHz oscilloscope
OX7202-CSD: 2 x 200 MHz oscilloscope
OX7204-CSD: 4 x 200 MHz oscilloscope
OX7104-CSDO: 4 x 100 MHz oscilloscope
OX7204-CSDO: 4 x 200 MHz oscilloscope
71
For further details…
oscilloscopes WITH ISOLATED CHANNELS
oscilloscopes WITH ISOLATED CHANNELS
Scopix Fieldbus
Advantages of the Patented Probix System
OX 7202-BUS & OX 7204-BUS
With the specific version for fieldbus integrity testing, SCOPIX BUS offers electrical and physical maintenance
of all your fieldbuses: AS-I, DALI, CAN, KNX, ETHERNET, MIL STD1553, ARIN159, USB, FLEXRAY, LIN, PROFIBUS
and RS232/485 according to the existing standards:
Link quality test
Simplified test
The diagram of the eye offers a visual
diagnosis to check and assess the
transmission quality of a digital bus.
Help with connection to the fieldbuses using cards equipped with
SUBD9 or RJ45 or M12 connectors
or 8-wire screw connectors: HX0190
and HX0191.
Help with troubleshooting in the User
Manual and the booklet of bus descriptions by standards.
The Probix system, with its smart
probes, accessories and adapters,
ensures quick, error-free implementation of your instrument.
With this "plug and play" measurement system, the probes and adapters are recognized immediately as
soon as they are connected. The instrument does not just identify them,
however. It also gives information on
their specifications.
Visual help for the steps, the overall
result in colour and the result of each
test in colour, along with pictograms
comparing the value to the tolerance
of the standard:
,
or
.
Help at connection with a reminder of
the input channels and the assembly
diagrams for each bus.
Scopix portable oscilloscopes benefit
from Probix smart accessories which
offer users a host of innovative
functions guaranteeing simplicity,
effectiveness, versatility and safety.
All the Scopix communication tools
are provided as standard, with:
The coefficients, scales, units and
channel configurations are managed
automatically
This system also allows users to
power the accessories directly from
an oscilloscope, without a battery or
additional mains adapter.
HX0034
Some Probix accessories include
three control buttons directly accessible on the probe. For example,
the first two control buttons on the
probes are used for direct modification of the parameter settings for the
channel to which they are connected.
HX0094
Active safety is built-in, notably in
the form of safety information and
recommendations for users based on
their specific configuration.
n SX-BUS bus creation and modification software for better adaptation
to the standards and any changes to
them: modification of the standard
limits, measurement tolerances in
MIN/MAX and % on SCOPIX BUS
HX0096
n Display of the results from the last
analysis: these results can be saved in a ".htm" file in the internal
memory (1 MB), on the SDCard
(2 GB max.) or on an FTP server.
And all the functions of SCOPIX III
are maintained + 50 kB + OX +
RECORDER + MX.
Probix current measurement
HX0034: 0.02 A to 60 ARMS AC/DC current clamp / 1 MHz
HX0072: 5 A to 3,000 ARMS AmpFLEX™ AC current sensor / 200 kHz
HX0073: 1 A to 300 ARMS MiniAmpFLEX AC current sensor / 3 MHz
HX0094: Probix 4-20 mA (process) adapter
HX0096: Probix BNC adapter/100 mV/A (standard sensors)
References to order
72
OX7202-BUS: oscilloscope 2 x 200 MHz
HX0190: DB9F and RJ45 connection cards
OX7204-BUS: oscilloscope 4 x 200 MHz
HX0191: M12 and 8-wire connection cards
Available accessories
See pages 110 to 118
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
73
www.metrix.fr
For further details…
oscilloscopes WITH ISOLATED CHANNELS
oscilloscopes WITH ISOLATED CHANNELS
The 4 Scopix modes
Advantages of the Patented Probix System
A multiple instrument for complete,
precise diagnosis
Probix voltage measurement
Probix voltage probe
HX0030B: 1/10 voltage probe, 1,000 V CAT II, 600 V CAT III,
250 MHz
HX0071: Industrial Accessories Kit for HX0030A probes (wire
grip, banana plug, 50 cm earth connection)
HX0030
HX0130
HX0130: 1/10 electronic voltage probe, 300 V CAT III, 500 MHz
Probix BNC
HX0029 recorder (Option)
HX0031: Probix adapter for BNC cables
Specifications
HX0032: Probix BNC adapter with built-in 50 Ω load
HX0071
Probix Banane
HX0033: Probix adapter for banana leads, 600 V CAT III
HX0093: Probix adapter with 300 Hz filter (PWM systems),
600 V CAT III
HX0095: Probix adapter for banana leads, 1,000 V CAT II
A multi-channel 200 kHz TRMS digital multimeter
HX0075 power measurement (Option)
HX0031
HX0033
Specifications
AC, DC and AC + DC voltages
General specifications
Resistance Other measurements
Temperature measurement
HX0035B: Probix / K Thermocouple adapter
HX0036: Probix / Pt100 Probe adapter
2 or 4-channel multimeter
8,000 counts - TRMS
600.0 mV to 600.0 Vrms or 800 mV
to 800.0 Vdc - accuracy Vdc 0.5% R
+ 5 D – bandwidth 200 kHz
2 or 4 channels – 8,000 counts max.
& Min/Max bargraph - TRMS
– Time/date-stamped graphic recording
80.00 Ω to 32.00 MΩ- accuracy 0.5% R
+ 25 D - 10 ms quick continuity test
Capacitance from 5.000 nF to 5.00 mF
/ Frequency 200.0 kHz / 3.3 V diode test
Acquisition rate Recording duration
Acquisition mode
Processing
Sampling interval of 800 μs to 17 min 51 s
– (standard memory 2,500 points)
Sampling interval of 40 μs to 53.5 s
- (with 50,000-point memory extension)
2 s to approx. 1 month
Conditioned by thresholds or windows
"Normal" acquisition or up to 500 faults
Time/date-stamped graphic recording,
conversion and units of physical
quantities, measurements using cursors
and event searches, file format compatible
with standard spreadsheet (“.txt”)
Recorder mode: 50,000-sample acquisition, maximum resolution 40 μs,
x100 zoom (one mains cycle)
In multimeter mode, the power measurements are
developed as follows:
n Single-phase power
n Three-phase power on balanced network without neutral
n Three-phase power on balanced network with neutral
Example of application
With a Probix AC/DC current probe powered by the oscilloscope and a Probix
1/10 1,000 V voltage probe, thanks to the automatic scaling, unit management
and the appropriate Math function (multiplication), you can view the
instantaneous power in real time and measure the value.
When 2 channels are multiplied, it is possible to view the scaled result, with its
physical unit (e.g. W) and the original curves (in this case, the current and the
voltage).
n 3-wire three-phase power (2-wattmeter method)
Display of apparent, active and
reactive power values and the PF
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
A memory of 50,000 points.
Specifications
Multi-channel
analysis
Processing
2 or 4 depending on model
61 orders – frequency of fundamental from
40 to 450 Hz in auto or manual mode
Permanent display: total RMS value & THD
selected order: %F, phase, frequency, Vrms
Selection of the type of network
supplying the load
Extension of the acquisition memory
HX0077 (Option)
74
HX0028 harmonic analysis (Option)
The "vertical zoom" (front-panel button) can be used to adjust the
dynamic range as required (0-100 %, 0-50 %, 0-25 %, or 0-10 %).
75
ACCESSORIES for oscilloscopes
ACCESSORIES for oscilloscopes
PC software
Software not requiring installation
SX metro
Virtual printer
USB-RS232 or Ethernet link
For printing ".gif" and ".bmp" files from SCOPIX/OX6000
on a network printer linked to a PC. The software
installed on a computer equipped with the drivers for the
network printer provides a direct gateway between the
oscilloscope and the printer, transforming the PC into an
LPD server. This software is a virtual print server which
processes the file so that no action is required from the
user.
The APPLICATIONS supplied with the SCOPIX-MTX105X and OX6000 models
ScopeAdmin
To control a fleet of instruments directly via a web
browser (oscilloscopes equipped with an Ethernet
connection).
ScopeNet
Android application
(available from Google Store)
ScopeNet for remote dialogue and parameter settings.
It then sends the prepared file to the network printer. As
a result, after configuring the oscilloscope, it is possible
to send screenshots directly for printing. This method is
simple, quick and effective.
This software can be used to view the curves in real time,
perform measurements and analyses, capture screens
and control METRIX® oscilloscopes from your tablet or
smartphone.
With this application, you can monitor the curves and
measurements on a METRIX® oscilloscope from the
OX7000, OX6000B or MTX105x series via an Ethernet
link.
ScopeNet
Application for remote control of an instrument using
a PC.
The data processing software for all METRIX®
oscilloscopes which allows you to:
n View the curves
n Display the curves on the PC in real time with the
oscilloscopes
n Control the oscilloscope remotely via the PC
n Load a configuration into the oscilloscope
n Import curves stored in the oscilloscope's memory,
using the following types of "image" files:
File name
Contents
a curve which will be displayed in the active graph
FTP server
a recording which will be displayed in a new graph
an instrument configuration
Application for remote control of an instrument using
a PC.
a screenshot
a graph with its curves and comments
a curve in persistence mode
n Store the curves on the PC in text format
n Perform mathematical processing such as the FFT of
the signal displayed
n Transfer the data (curves or FFT) into Excel
76
77
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
SPECTRUM ANALYSER CONNECTED TO A PC
SPECTRUM ANALYSER CONNECTED TO A PC
Spectrum analysis
Spectrum analysis can be used to measure the band, detect disturbance lines, quantify phase jitter by
direct reading, check the steps, determine the rated frequency, search for residual lines for comparison,
etc.
Heterodyne spectrum analyser
Spectrum analysis involves moving a narrow
bandwidth filter in front of the signal to be
analysed. However, because of the difficulty of
producing a narrow bandwidth filter with an
adjustable mid-band frequency, the problem is
avoided by "heterodyning".
With this technique, the bandwidth filter has a
fixed mid-band frequency of F0 and the signal to
Signal
to be
analysed
Multiplier
be analysed is modified by modulation, so that the
different frequency components are successively
modulated to the frequency F0. To achieve this, a
multiplier is used which outputs the sum and the
difference of the frequencies applied to the two
inputs, resulting from the trigonometric relation:
cos(a)cos(b) = (1/2)[cos(a+b) + cos(a-b)].
Summer
Noise power and power of a line
Video filter
The analytical filter indicates the power of the F0
line when it is centred on it (leaving aside the filter
losses which can be compensated). Whatever
the width of the filter, the maximum height of the
curve on screen will correspond to the power of
the line.
This serves to smooth the curve on the screen,
particularly at the noise level. It has no effect on
the actual measurement, as it only applies to the
on-screen display of the curve. However, it may
affect the sweep time: a 10 Hz video filter will not
deliver more than 10 data items per second, so if
1,000 points are necessary to plot the curve, it will
not be possible in less than 100 seconds.
Noise measurement depends on the
width of the analytical filter
This means that phase jitter can be measured
with the spectrum analyser, in dBc/Hz, which is
the difference in dB between the F0 line power
measurements in dBm and the noise power in
dBm/Hz at a given distance from the carrier.
Peak detection
Bandwidth
filter centred
on F0
Ramp
generator
POWER (dBm)
Oscilloscope
Block diagram of a heterodyne spectrum analyser
Carrier
The analytical filter
78
The analytical filter is also called the resolution
filter. The narrower the filter, the finer the analysis
and the closer you get to the shape of the line
analysed (because the filter itself resembles a line).
Using different reasoning, it could also be said that
a signal passing through an extremely narrow filter
can only come out as a pure sine wave, represented
by a line!
It is tempting to use a narrower filter to analyse
a signal, but compromises need to be made. The
narrowness of the filter limits the amount of data
that it can supply per second, which means that,
to obtain a large number of measurement points
(i.e. better frequency resolution), more time will be
necessary with a narrow filter than with a wider
filter.
NOISE
POWER (dBm)
3 dB
Resolution filter band
(here 3 KHz)
Noise measurement with several analytical filters
10 KHz / Div.
Width of analytical filter
Detailed product brochures can be downloaded free of charge from www.metrix.fr
79
www.metrix.fr
SPECTRUM ANALYSER CONNECTED TO A PC
SPECTRUM ANALYSER CONNECTED TO A PC
CAT II
MTX 1050
Specifications
The lightweight, portable MTX1050 general-purpose spectrum analyser
is particularly suitable for the needs of small businesses and technical
education.
When coupled with the H-field probes, the MTX1050-PC analyser can be used to carry out EMC prequalification tests.
n Particularly compact and
economical "screenless"
instrument
n User interface via PC: "Plug &
Play" USB connection, large highresolution colour display
n 4 simultaneous measurements
(Peak auto, Marker, 2 difference
cursors)
n Frequency range from 400 kHz
to 1 GHz
n High stability with frequency drift
limited to ±5 ppm/year
n Wide dynamic range for
measurement, from -90 dBm to
+20 dBm
n 6 sweep speeds, 3 analytical
filters and 3 video filters, built-in
FM demodulation
n Ideal for EMC testing
PEAK cursor
Free cursor
DELTA cursors
MTX 1050
Frequency
Display
Colour display, high resolution, large dimensions, on PC screen
Up to 5,000-point sweep in horizontal resolution (depending on speed)
Bandwidth
400 kHz to 1 GHz
Resolution on central frequency value
4 1/2 digits / 10 kHz maxi
Internal frequency
Accuracy ±0.625 10-6
Frequency stability
±5 ppm / 1 year
Frequency span
Zero Span, 1 MHz to 100 MHz / div - sequence 1-2-5
Resolution
Filters
12 kHz, 120 kHz and 1 MHz
Video filters
1 kHz, 10 kHz and 300 kHz
Level
Dynamic range for input
3 ranges from -90 dBm to +20 dBm
Noise floor level
Without amplifier: -80 dBm
(dynamic range for measurement)
With amplifier: -95 dBm
Dynamic range for display
50 dB and 100 dB
Harmonic response
< -40 dBc for a level of -20 dBm
Non-harmonic response
< -70 dBc (< -600 dBc on identified frequencies)
Input
Max. admissible power
+25 dBm permanent, ±30 Vdc
Impedance50 Ω rated
Input attenuation
One 20 dB-rated attenuator, one 20 dB-rated amplifier
ConnectorBNC
Markers / Modes
4 simultaneous cursors / 1 automatic "Peak" detection marker,
1 cursor "locked" to the trace and 2 delta cursors
Functions
Data storage
On PC, unlimited number, with explicit names
Storage and comparison of reference spans
100 to 5,000 samples per sweep (depending on sweep speed)
Traces
Averaging (factors 2 to 64 / noise suppression and improvement of dynamics
Comparison to a reference and measurement of deviations (frequency & amplitude)
Calculation of difference (Spectrum – Reference) and associated measurements
Screenshot with all settings - Transfer to Excel
PC communication
"Plug and Play" USB as standard
Mains power supply
230 Vac, ±10 %, 50/60 Hz, approx. 4 W
Safety / standards
IEC 61010-1 - CAT II / NF EN 61326-1: 98
Dimensions / Weight
270 (L) x 63 (H) x 215 (W) mm / 1.7 kg
Specific accessories
Standard state at delivery
HX0082: H-field probes kit, 3 GHz
HX0083: 20 dB amplifier for HX0082 probes
1 MTX, 1 mains power cable, 1 CD-Rom containing the PC
application software, 1 FM antenna with BNC connection,
1 user manual
Reference to order
MTX1050-PC: 1 MTX 1050PC spectrum analyser
Available accessories
See page 114
80
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
81
For further details…
SPECTRUM ANALYSER
FOR EMC PREQUALIFICATION TESTS
GENERATORS
Spectrum analyser and near-field probes
Generator basics
MTX 1050, HX 0082 & HX 0083
Function generators are among the most widely-used test and measurement instruments. They can
generate varied characteristic waveforms in order to test the operation of electronic systems, from very
low frequencies of just a few mHz up to 20 MHz or more.
It allows users to adjust the amplitude of these signals up to 20 V or more, possibly with the presence
of a DC component.
In addition, they may also provide modulations or specific functions.
A set of instruments specially designed
for EMC prequalification tests
These tests may take place throughout the design
and development of a product.
Prequalification tests help to save time and make
sure that the finished product will comply with the
applicable standards.
These tests take into account all aspects which
help to limit disturbances:
• Choice of components and floorplan on printed
circuit boards
• Reduction of cable lengths and use of screened
cables when possible
• Separation of circuits/cables of different types
(e.g. analogue or digital)
• Checking of electrical continuity (e.g. connections, welds, etc.)
• Verification of the floorplan and screening, etc.
This is not an exhaustive list. Any measurements
that may reduce electromagnetic fields should be
envisaged to ensure that the product operates
correctly.
The tests are divided into 2 main categories:
immunity tests and emission tests. They are also
performed in 2 distinct modes: “conducted mode”,
covering disturbances in the cables or printedcircuit traces, and "radiated mode" for the electromagnetic field in the air.
LABORATORY INSTRUMENTATION
Direct Digital Synthesis (DDS) function generator
HX0082 near-field probes & HX0083
amplifier
The HX0082 kit comprises 2 near-field probes (30
MHz – 3 GHz). The proximity probe can be used
to measure radio-frequency magnetic fields. It can
be positioned up to 10 cm from the target. The
contact probe is designed for precise measurements on chip floorplans or traces.
Specifications
Power supply voltage
Current consumption
Max. input voltage
Gain
Noise
HX 0083
7.5 to 18 V
50 mA
25 Vdc
20 dB
4.5 dB
Direct Digital Synthesis (DDS)
function generator
Basic principle:
DDS function generators generate periodic signals
at precise frequencies by choosing samples in the
memory rather than producing all the samples of a
signal. This technique offers exceptional accuracy
and stability, high spectral purity, low noise and
excellent frequency agility. It is possible to modify
the frequency without phase discontinuity.
It is important to note that signal generation with
the DDS method differs significantly from the
method used by an arbitrary signal generator.
For arbitrary signal generation, each sample of the
signal period built and stored in the memory is
generated sequentially.
For signals generated with DDS technology, a
single signal period is stored in the memory, but
only certain samples are generated to create the
waveform and the required frequency, as shown in
the illustration below:
Generation of a 21 MHz signal with direct digital synthesis (DDS)
82
Measurements with the HX0082 contact probe
Measurements with the HX0083 proximity probe up to 10 cm
from the target
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
83
GENERATORS LABORATORY INSTRUMENTATION
GENERATORS LABORATORY INSTRUMENTATION
A few definitions
Signal waveforms
The generator can typically generate sine, triangle and
square waveforms, as well as their usual derivatives.
Frequency range (expressed in Hertz (Hz)
This is the difference between the minimum frequency
and maximum frequency that the generator is capable
of producing. This frequency range is defined for a
sinusoidal waveform. It should be noted that a smaller
frequency range is usually specified for triangular or
square waveforms. The minimum frequency, which
may be just a few mHz, is used to simulate slow
phenomena (mechanical or physical) or to control
slaving (for example, a triangular ramp profile).
Resolution
This is the smallest measurable value difference. It is
expressed in digits and its absolute value depends
on the frequency range used. For the GX320, for
example: 5-digit resolution at 20 MHz corresponds to
a 1 kHz increment.
Frequency accuracy
This corresponds to the difference between the true
value of the signal's frequency and the value displayed.
It mainly depends on the quality of the oscillator used,
for which short-term and long-term stabilities are
defined, expressed in ppm (parts per million). For
example, for the GX320: +/- 20ppm when F > 10 kHz.
Selection guide
BURST function
Specifications
The BURST function can be used to generate pulse
trains: users define the train generation period and
the number of pulses in the train.
It also provides a means of generating a signal with
a very large duty cycle (1 brief pulse with a long
repetition period).
GATE function
GX305 GX310GX320
Number of channels
1 11
Max. frequency (MHz)
5 1020
Display
LCD (125 x 45 mm) - 5 digit
Signal waveforms
sine, triangle, square & logic+TTL
Sweep
•
•
•
AM/FM modulation
•
FSK/ASK function
•
BURST function
•
GATE function
•
MASTER/SLAVE function
•
Frequency meter
100 MHz
Arbitrary function
SX-GENE software
Easywave software
Pages86-87
Num = number of pulses
Time = generation period
This superimposes over the current function a start/
stop command for the AC component of the MAIN
OUT signal. This function can be controlled internally
or by a TTL signal injected on a dedicated BNC
connection.
MASTER/SLAVE function
SWEEP function
The "SWEEP" function can be used to generate a
frequency sweep in rising or falling mode. This sweep
can be controlled by the generator according to a
linear or logarithmic law or on the basis of an external
sawtooth or triangular signal applied via a dedicated
BNC connection.
Types of modulation
AM: Amplitude Modulation
FM: Frequency Modulation
FSK function: Frequency SKip controlled internally or
externally.
PSK function: "Phase SKip" whose value is controlled
by an internal or external command signal.
Specifications
GX1025GX1050
This can be used to synchronize several GX 320s set
up in a "cascade" arrangement. The generator used
as the "Master" supplies the other "Slave" instruments
with the clock (Clk) and a synchronization signal
(Ctrl). This enables all the generators to start up at
the same time and allows users to control their phase
offset.
84
DOX3104
DOX3304
Number of channels
22
1
Max. frequency (MHz)
2550
25
Display
3.5" colour TFT
8”
Signal waveforms
sine, triangle, square,
ramp, pulse, white noise, Arb
Sweep
•
•
AM/FM modulation
•
•
FSK/ASK function
•
•
BURST function
•
•
GATE function
•
•
MASTER/SLAVE function
Frequency meter
200 MHz
Arbitrary function
•
•
•
SX-GENE software
•
•
Easywave software
•
Pages 88-89
62
85
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
LOW-FREQUENCY generators
LOW-FREQUENCY generators
DDS function generators
Specifications
GX 305, GX 310 & GX 320
Multi-function, stand-alone, innovative laboratory generatorstesters!
Ergonomics: uniquely easy to read!
The GX generators have a large LCD screen (125 x 45 mm) offering
exceptionally easy reading thanks to the main display's 5 digits 20 mm
high. In addition, the GX generators can simultaneously display all the
parameter settings (VDC, Vrms or Vpp, waveform, etc.).
n Frequency range from 0.001 Hz
to 10 MHz (GX310) or 20 MHz
(GX320)
n AM/FM modulation (GX320)
n DDS technology with a frequency
accuracy of +/-20 ppm
n Storage of 15 complete instrument
configurations (GX320)
n Adjustment of stable frequency to
the nearest digit
n "Logic signal" function for direct
adjustment of the high and low
levels (TTL, CMOS, etc.)
n GATE, BURST, FSK and PSK
functions (GX320)
Specific innovative function:
Adjustable-phase synchronisation
of several generators in a cascade
arrangement (GX320.
n 100 MHz frequency meter,
300V CAT I
n Versions programmable via
USB link with the standard SCPI
protocol
Synchronization of several generators in a
cascade arrangement
The "SYNC" function on the GX 320 allows
several generators to be set up in a cascade
arrangement to make a variable-phase
multiple-signal generator. A first GX 320,
used as the "Master", provides the other
"Slave" instruments with the clock used
to generate the signals. It also supplies
the synchronizing pulse to start all the
instruments simultaneously. In this way,
the phase shift of each signal is controlled.
GX 320 Master
GX 320 Slave 1
GX 320 Slave 2
Example 1: simulation of a three-phase signal
Channel 1: master (0°)
Channel 2: slave1 (120°)
Channel 3: slave2 (-120°)
86
Accessories and replacement parts
Standard versions
– 1 function generator, 1 mains power cable, 1 CD-Rom
containing: 1 user manual in 5 languages, 1 programming
manual in FR + EN, LabWindows CVI / LabView drivers
AG1066-Z: set of 2 BNC-banana leads with rear connection
HX0106: Set of 2 BNC-BNC leads 1 m long
HX0107: Set of BNC-banana adapters
HA2004-Z: Set of 3 BNC T-fittings
Available accessories
See page 114
www.metrix.fr
GX 320
Standard state at delivery
Programmable versions
– 1 function generator, 1 mains power cable, 1 CD-Rom
containing: 1 user manual in 5 languages, 1 programming
manual in FR + EN, LabWindows CVI / LabView drivers, 1 USB
A/B cable - Ethernet version – The same + 1 Ethernet cable
Example 2: Fourier synthesis
Synchronization of the generators (3 in this
example) allows simulated synthesis of a
square signal from its primary harmonics.
Detailed product brochures can be downloaded free of charge from www.metrix.fr
GX 305 / GX 310
Human-machine interface
Display
LCD (125 x 45 mm) – Adjustable brightness – Frequency display with 5 digits 20 mm high
Adjustment of signal parameters
Continuous by encoder, auto-ranging for Frequency and Level, selection of increment digit (F, P, N, etc.) ?
BNC output terminals on front panel
TTL & Sweep Out outputs
TTL, Sweep, Clock and Synchro outputs
BNC input terminals on front panel
VCF in input
VCG, Gate; Clock and Synchro inputs
Continuous signal generation
Frequency 0.001 Hz to 10.000 MHz (9 ranges - GX 305)
0.001 Hz to 20.000 MHz (11 ranges)
0.001 Hz to 10.000 MHz (10 ranges - GX 310)
Resolution / Accuracy
5-digit display – resolution from 1 mHz to 1 kHz depending on range
/ 10 kHz, ± 30 ppm for F < 10 kHz
Amplitude
1 mV to 20.0 Vpp with open circuit in 3 automatic ranges –3-digit display Vpp or Vrms – Max. resolution 1 mV
Flatness < 5 % for 1 mHz < F < 10 MHz , and ± 0.5 dB typ. up to 20 MHz (GX 320) (specs for a level from 0.1 Vpp to 20 Vpp)
Signal form Sine / Triangle (max. frequency 2 MHz) / Square & "LOGIC" / TTL output
Frequency sweep
Modes
LIN (linear) or LOG (logarithmic)
"Sawtooth" or "Triangle" mode – Unlimited span between "F Start" & "F Stop"
INT internal sweep
Sweep time adjustable from 10 ms to 100 s
EXT external sweep
Sweep by signal < 15 kHz, amplitude ± 10 V
Modulation
Internal AM modulation Modulation by a 1 kHz sine signal
Modulation rate 20 % or 80 %
External AM modulation Modulation by a signal < 5 kHz, with amplitude ± 10 V
for 0 to 100 % modulation (VCG IN)
Internal FM modulation
Modulation by a 1 kHz sine signal
Unlimited span between "F Start" & "F Stop"
External FM modulation
Modulation by a signal < 15 kHz
Amplitude ± 10 V (VCG IN)
SHIFT K function Frequency hop, internal or external phase jump
Burst function
Internal BURST
1 to 65,535 pulses
Period of pulse trains 10 ms to 100 s
External BURST
1 to 65,535 pulses – Synchro/Period
by a TTL signal with frequency < 1 MHz (VCG IN)
Gate function
Validation of AC component from "Main Out"
by a TTL signal with frequency < 2 MHz (GATE IN)
Synchro function
Cascade configuration Maximum frequency of generated signals 100 kHz
of several GX 320s Adjustment of phase shift to ± 180° (resolution 1°)
External frequency meter
Measurement range / accuracy 5 Hz to 100 MHz / ± 0.05 % + 1 digit
Safety / max. admissible voltage
300 V CAT I / 300 Vrms
General specifications
Storage/Recall of 15 complete instrument configurations
Configuration memories
Communication interface "USB A/B" link for the programmable versions (P) and Ethernet for the GX 320-E
Mains power supply
230 V ± 10 % (or 115 V ± 10 %) – 50/60 Hz – 20 VA max. – Removable lead
Safety / EMC
Safety as per IEC 61010-1 (2001) – EMC as per EN 61326-1 (2004)
Mechanical specifications
227 (L) x 116 (H) x 180 (W) mm – Weight 2.8 kg
Warranty
3 years
References to order
GX305: 5 MHz function generator
GX310: 10 MHz function generator
GX310-P: Programmable 10 MHz
function generator
GX320: 20 MHz function generator
GX320-E: Programmable 20 MHz
function generator
For further details…
87
ARBITRARY FUNCTION generators
generators ARBITRARY FUNCTION
DDS function generators
Specifications
GX 1025 & GX 1050
These multi-function, communicating laboratory generatorstesters with built-in frequency meter are ideal for all R&D lab,
testing and production applications, as well as for technical
training and higher education.
GX 1025, 25 MHz
n Large 320 x 240 mm TFT LCD
screen with high contrast for
better visibility, intuitive front
panel and simple use
n Memory depth of up
to 16 kpoints, allowing
reconstruction or simulation of
any type of complex signal
n DDS technology on 2 outputs for
coupling or duplication
n Generator user interface and
integrated help in English
n Generation of standard signals
such as sine, square and triangle,
as well as more complex signals:
pulse, ramp or white noise
n USB interface on front panel for
data storage
n Generation of arbitrary signals
which are precise, stable and
pure, with low distortion at a
sampling rate of 125 MS/s on 14bit resolution
n USB interface on front panel
for programming and control of
the instrument via the SX-GENE
software
n Internal SWEEP wobble
modulation: external or manual,
linear or logarithmic
GX 1050, 50 MHz
n The integrated AM, FM, PM,
ASK and FSK modulation
functions can be used to
generate modulated signals very
easily without an independent
modulation source
SX-GENE v2.0 can be used to control a GX 1025 or GX 1050 arbitrary
function generator, save and recall configurations and generate arbitrary
signals.
It allows:
n Data transfer in .arb files (from the
generator to the PC)
GX 1050 (rear view)
n Recovery of a signal from a
METRIX® oscilloscope curve (.trc
file transferred into the generator)
n Configuration of the generator
(.cfg)
GX 1025GX 1050
Human-machine interface
Display
Large high-contrast 3.5 ‘’ TFT colour screen / Resolution 320 x 240
Controls on front panel
18 direct-access buttons, 1 rotary button
Adjustment of signal parameters
Continuous adjustment by the encoder and/or numeric keypad
BNC output terminals on front panel Generator outputs 1 & 2 - Separate adjustment (waveform, f, phase, amplitude, etc.), coupled or duplicated
BNC I/O terminals on rear panel TTL-compatible trigger and synchronization outputs
Continuous signal generation
Signal types
Sine, Square, Triangle, Ramp, Pulse, White Noise, Arbitrary Signal (48 pre-installed waveforms)
Arbitrary signal generation
Resolution / Sampling rate
14 bits / 125 MS/s
Memory
16k memory depth (512k on CH1 only) - Storage of predefined or specific signals on USB key
Editing of signals with SX-GENE
Acquisition, transfer & modification of a signal acquired from an oscilloscope (OX6000, OX7000, [email protected])
Graphical or mathematical editing with the SX-GENE software
Signal frequency
Sine from 0.001 mHz to 25.000 MHz,
Sine from 0.001 mHz to 50.000 MHz,
Triangle 300 kHz, Noise and Square 25 MHz, Triangle 300 kHz, Noise and Square 50 MHz,
Frequency range
Pulse 10 MHz, Arbitrary Signals 5 MHz
Pulse 20 MHz, Arbitrary Signals 5 MHz
Resolution / accuracy
7-digit display – resolution from 1 mHz to 1 kHz depending on frequency range
± 20 ppm for F > 10 kHz , ± 30 ppm for F < 10 kHz
Long-term drift
± 100 ppm / year
Temperature coefficient
< 5 ppm / °C
Amplitude
Voltage levels
Output 1 = 2 mVpp ~ 10 Vpp 50 Ω) 2 mVpp ~ 20 Vpp (open circuit)
Output 2 = 2 mVpp ~ 3 Vpp (50 Ω) 2 mVpp ~ 6 Vpp (open circuit)
Flatness
< 0.1 dB for f < 100 kHz
Output 1 = ± 10 Vdc (open circuit), Output 2 = ± 3 Vdc (open circuit) – accuracy ± 1% ± 1 mV
Vdc offset
Impedance / Protection50 Ω / Protection against short-circuits
Signal characteristics
Sine
Distortion < 0.2 % typical for f < 20 kHz, and harmonics < -50 dBc for DC < f < 25 MHz (level < 1 Vpp)
Triangle (max. frequency 2 MHz)
Linearity error < 1% max
Square & pulse
Rise time < 12 ns (typ.) – Duty cycle 20-80% (DC < f < 20 MHz) – Pulse 20 ns to 2,000 s
Modulation (internal or external source)
Carrier: Sine, Square, Triangle, Arbitrary (except DC)
AM modulation
Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz)
Modulation depth: 0% to 120%
Carrier: Sine, Square, Triangle, Arbitrary (except DC)
FM modulation
Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz)
Modulation depth: 0% to 120%
Frequency offset: 0 to 12.5 MHz
Frequency offset: 0 to 25 MHz
Carrier: Sine, Square, Triangle, Arbitrary (except DC)
FSK modulation
Modulated signals: 50% of duty cycle (2 mHz to 50 kHz)
Carrier: Sine, Square, Triangle, Arbitrary (except DC)
ASK modulation
Modulated signals: 50% of duty cycle (2 mHz to 50 kHz)
Carrier: Sine, Square, Triangle, Arbitrary (except DC)
PM modulation
Modulated signals: Sine, Square, Ramp, Triangle, Noise, Arbitrary (2 mHz-20 kHz)
Phase offset: 0 to 360°
Other functions
Carrier: Sine, Square, Ramp, Triangle, Arbitrary (except DC) - Type: Linear/Logarithmic
Sweep
Direction: Increasing or Decreasing - Sweep time: 1 ms to 500 s - Trigger: Manual, External, Internal
Signals: Sine, Square, Ramp, Arbitrary (except DC) - Type: Short (1-50,000 cycles),
Burst
Infinite, Gate - Phase start/stop: -180° to +180° - Internal period: 1 μs to 500 s ± 1%
External frequency meter
Measurement range / resolution
100 mHz to 200 MHz
Sensitivity / Input impedance
20 mVrms for 100 mHz < f < 100 MHz, 40 mVrms beyond / 1 MΩ
General specifications
Data storage
Storage of predefined or specific signals and complete instrument configurations on USB key
Communication interface
USB Device, USB host
The SX-GENE software can be downloaded free of charge from our support website, along with the LV and LW drivers
Software
Mains power supply
100~240 VACRMS 45~440 Hz CAT II - < 30 W
Mechanical specifications
229 mm x 105 mm x 281 mm - 2.8 kg
Warranty
1 year
n Recovery of an arbitrary signal
stored in one of the generator's
10 memory locations
88
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Standard state at delivery
References to order
1 GX delivered with 1 mains power
cable, 1 USB cable, 1 user manual,
1 programming manual on CD-Rom
and the SX-GENE v2.0 software
GX1025: 25 MHz arbitrary function
generator
GX1050: 50 MHz arbitrary function
generator
Available accessories
See page 114
89
laboratory POWER SUPPLIES
laboratory POWER SUPPLIES
Power supply basics
DC power supplies offer constant, controlled current and voltage output. A power supply can be seen
as an AC/DC converter which takes energy from the electrical network (230 V/50 Hz) and passes on
part of that energy.
The linear technology used in our AX 5xx power
supplies is based on a toroidal transformer which
reduces the weight and improves efficiency while
providing the following features:
• Protection against short-circuits, overloads and
overheating
• Double-well safety output terminals and doublewell male safety earth terminal
• Toroidal transformer compliant with the
EN60742 standard with outputs doubleinsulated in relation to the mains supply: no
forced ventilation to reduce noise and low
radiation
• Serial or parallel coupling of the outputs and
loop control of the outputs with the Tracking
mode.
Output modes
• Independent mode: the output voltage and
current on each channel are controlled separately. The level of insulation between the output
terminal and the chassis, or between output
terminals, is fixed.
• Tracking mode: the two CH1 and CH2 outputs
are automatically connected in series or in
parallel.
Coupling
• Series: the output voltage is doubled
• Parallel: the output current is doubled.
AX 501
AX 502
As well as being particularly rugged, these power supplies are also
lightweight, economical and based on the latest technology!
The AX 501, AX 502 and AX 503 laboratory power supplies with 1, 2 or
3 outputs offer electronic limitation of the current in the event of shortcircuit and temperature control in the event of overload or overheating.
Their linear technology is based on a toroidal transformer which halves
their weight and improves their efficiency.
n Linear technology: stability, low
noise, good response to current
demand
n Active protection against
short-circuits, overloads and
overheating
n Adjustable current limitation on
the 30V outputs
n A third adjustable 2.7 V-5.5 V/5 A
output on the AX 503 can be
used to power logic circuits (TTL/
CMOS)
n Outputs with double insulation in
relation to the mains
n Compact and lightweight
n Series or parallel output coupling
for generating up to 60 V / 2.5 A
or 30 V / 5 A
n An earth terminal with reversed
polarity to avoid connection errors
n Dual-well safety terminals
n Coupling of the two 30 V outputs
in "tracking" mode in order to
adjust them simultaneously
(master/slave)
A programmable DC power supply is adjustable
and offers multiple functions. These power supplies
are usually equipped with independent outputs:
• With an adjustable voltage level
• or a fixed voltage.
The power supply can be used to power logic
circuits for voltage or current requirements of
different levels.
Selection guide
AX 501, AX 502 & AX 503
Specifications
AX 503
AX 1360-P
1 channel
X
X
X
2 channels
X
X
2 channels + 1 fixed
X
Tracking mode
X
X
Programmable
Ventilation
Memory
USB
X
X
X
X
X
X
X
X
AX 501
AX 502
AX 503
Technology Linear
Display
Green and red LEDs - 3 digits
Outputs 1 x (30 V/2.5 A)
2 x (30 V/2.5 A)
2 x (30 V/2.5 A)
1 x (2.7 to 5.5 V/5 A)
Output coupling Series or parallel
Output tracking Yes ("track" mode)
Special features
Electronic protection against short-circuits,
overloads and overheating.
Output double insulated from mains
Toroidal transformers
(no forced ventilation and low emissions)
Double-well safety terminals
IEC 61010 - 1 safety
CAT I, 100 V
Power supply 110, 230 V
Dimensions (H x L x P)
120 x 225 x 270 mm
Weight 4 kg 4.5 kg 6 kg
Warranty 3 years
Standard state at delivery
References to order
Available accessories
1 AX power supply, 1 power cable,
1 user manual
AX0501A: AX501
AX0502A: AX502
AX0503A: AX503
See pages 102 et 103
Specific accessory
P01295073A - Reverse-polarity earthing
cable (green/yellow)
90
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
91
For further details…
LABORATORY POWER SUPPLY
TRAINING EQUIPMENT COS-PHI METER, BOXES, SHUNTS
Programmable power supply
Training boxes and shunts
AX 1360-p
Performance and simplicity at the best price!
n 2 adjustable outputs (0-30 V) and 1 selectable fixed
output (2.5 V / 3.3 V / 5 V)
n High stability and low drift over time, whatever the
mode
n Bright colour display of the currents and voltages
simultaneously on 3 digits
n Protection against voltage surges, overheating and
short-circuits
n Simplified use thanks to serial or parallel coupling
without leads
n Ventilation control according to the output power
n Quicker setup with 4 configurations available for recall
on the front panel
n USB communication
Specifications
Simple resistance boxes
P03197521A
0.1 to 1 Ω
P03197522A
1 to 10 Ω
P03197523A
10 to 100 Ω
P03197524A
100 to 1,000 Ω
P03197525A
1 to 10 kΩ
P03197526A
10 to 100 kΩ
P03197527A
100 to 1,000 kΩ
P03197528A
1 to 10 MΩ
4, 5, 6 and 7-decade resistance boxes
P01197401BR 04 : 4 decades 1 Ω to 10 kΩ
P01197402BR 05 : 5 decades 1 Ω to 10 kΩ
P01197403BR 06 : 6 decades 1 Ω to 10 kΩ
P01197404BR 07 : 7 decades 1 Ω to 10 kΩ
Coupling jumpers
P01101892A19 mm spacing - Ø 4 mm - 36 A
AX 1360-P
Frequency
Display
Digital with LEDs – Simultaneous voltage and current in colour
Number of outputs3
Voltage control
Output 1
0 – 30 V
Output 2
0 – 30 V
Output 3
2.5 V / 3.3 V / 5 V
Current control
Independent
Parallel
Output 1
3 A
6A
Output 2
3 A
6A
Output 3
3 A
–
Accuracy
Voltage
±(0.5 % reading + 2 digits)
Current
±(0.5 % reading + 5 digits)
Resolution
Voltage
10 mV (0 to 9.99 V) – 100 mV (10 to 30 V)
Current
10 mA
Ripple and noise
Voltage
< 1 mVrms
Temperature coefficient
Voltage
< 300 ppm / °C
On-load
Independent and parallel
Voltage control
< 0.1 % +5 mV
Current control
< 0.2 % +3 mA
Protection
Short-circuits
Current limitation and visual indicated by red LED
OvercurrentFuse
"SAVE/RECALL" function
No. of stored configurations4
Technical Specifications
Current and voltage adjustment
Output 1 and 2 by potentiometers, Output 3 by switch
Interface / SoftwareUSB
Mains power source
110 V – 220 V / 50 Hz – 60 Hz
Safety / Protection
IEC 61010-1 300 V CAT II / Fuse
Mechanical specifications
Dimensions: 310 x 250 x 150 mm – Weight: 7.5 kg
Warranty
1 year
Double changeover switch box
P03197529A2 switches with make/break/
non-locking make
Simple changeover switch box
P03197530 A1 changeover switch with make
break/reverse make
Inductance box
P01197451BL 07: 7 decades - 1 μH to 10 H
Measurement shunts HA030-1
(Class 0.5 compliant
with the IEC 61010-1
standard, 600 V CAT III)
HA050
HA050-1
Max. current Voltage drop
30 A
50 A
50 A
300 mV
100 mV
50 mV
BK
R1
R3
G
B2
R2
Standard state at delivery
X
AX1360-P: 1 programmable power supply, 1 power cable, 1 USB cable,
1 CD-Rom containing the user manual and the LV/CVI drivers
92
References to order
Available accessories
AX1360-P
See pages 102 et 103
B1
B2
For further details…
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Capacitance decade boxes
P01199613A
0.01 to 0.1 mF
P01199612A
0.1 to 1 mF
P03199611A
1 to 10 mF
P01197421BC 05: 5 decades - 1 nF to 10 μF
Null galvanometer
P03197611A Bandwidth: 60 and 100 MHz
Dial with anti-parallax mirror,
accuracy ±2.5 %
2 calibres by pushbutton
Ratio boxes
P03197531A
7 ratios: from 1/1,000 to x 1,000, accuracy ±0.2 % for Wheatstone bridge application
Bat
G = null galvanometer
BK = K ratio box with K = R2/R1
R3 = resistance box X =resistance to be measured with X = K x R3
B1 = simple changeover switch box
B2 = double changeover switch box
Bat =power supply
93
LABORATORY calibrator
V
laboratory calibrator
A
Multi-function calibrator
CX 1651
Specifications
CX 1651
Designed for measuring instrument manufacturers seeking to
calibrate their instruments, the CX 1651 is particularly accurate and
stable.
Based on a new concept, the CX 1651
generates:
It can be used to calibrate a wide
variety of instruments:
n standard electrical parameters for
temperature or energy applications
n Multimeters
n non-harmonic signals for testing
equipment when the distortion on
the input signals is non-null.
n Switchboard equipment
n Analogue instruments
n Current clamps
n Portable calibrators
n Wattmeters
n Electrometers
n Oscilloscopes
DC
6 ranges from 0 V to 1,000 V
Voltage
AC
6 ranges from 1 mV to 1,000 V
DC
6 ranges from 1 μA to 20 A
Current
AC
6 ranges from 1 μA to 20 A
Resistance
(4-wire set-up) 10 ranges from 0 Ω to 50 MΩ
Capacitance (4-wire set-up) 9 ranges from 900 pF to 50 μF
PWM
0.1 Hz to 100 kHz
Frequency
(pos, neg, sym)
HF (rise time 0.1 Hz to 100 kHz
< 5 ns)
Voltage from 200 mV to 240 V
DC
Current from 2 mA to 10 A
Voltage from 200 mV to 240 V Power
Current from 2 mA to 10 A Energy
AC
Frequency from 40 Hz to 400 Hz
Power factor –1 or +1 Phase from 0 to 360°
R, S, B, J, T, E, K, N
Thermocouple
Temperature
Ranges from –250 °C to +1,820 °C
sensor
Pt 1385, Pt 1392, Ni
RTD sensor
Ranges from –200 °C to +850 °C
Maximum voltage
supported by the
load: 8 Vpk
Acquisition time
in energy mode
10 s to 1,999 s
n Thermometers
n Loggers, etc.
Multimeter
Function
Vdc (DC voltage)
mVdc (DC voltage)
mAdc (DC current)
FREQ (Frequency)
R4W (Resistance)
TRTD (RTD sensors)
TTC (TC sensors)
SGS (deformation)*
Range 0 - ± 12 V
0 - ± 2,000 mV
0 - ± 25 mA
1 Hz – 15 kHz
0 - 2 kΩ
-150 °C – +600 °C
-250 °C – +1,820 °C
Depending on sensor
Accuracy
0.01 % + 100 μV
0.01 % + 10 μV
0.02 % + 1 μA
0.005 %
0.02 % + 100 mΩ
0.1 °C
0.4 - 4 °C
0.01 % + 10 μV + sensor accuracy
Standard state at delivery
1 multi-function calibrator delivered with 1,000 V / 20 A test
cables (x 2), 1 Option 40 cable adapter (Canon 25/2 x banana
cable adapter, 1 m), 1 Option 60 cable adapter (Canon 25/4 x
banana cable adapter, 1 m), 1 Option 70 cable adapter (adapter
for resistances on four terminals), 1 RS 232 cable, 1 power cable,
2 spare fuses, 1 test report and 1 user manual.
94
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
Reference to order
Available accessories
CX1651: 1 CX 1651 multi-function calibrator
See pages 102 et 103
95
For further details…
ACCESSORIES for MULTIMeterS
ACCESSORIES for oscilloscopes
Choosing your current clamp
There are multiple criteria for choosing a current clamp.
The approach below helps to specify your requirements and guide you
naturally towards the most suitable model for your application.
The CHAUVIN ARNOUX Catalogue contains a complete list of the clamps
available.
There are multiple criteria for choosing a probe.
The approach below helps to specify your requirements and guide you
naturally towards the most suitable model for your application.
To choose your clamp, we advise you to follow the logic presented below:
To choose the probe to adapt to your oscilloscope, we advise you to follow
the logic below:
Measurement input
n Measurement of DC or AC currents? (see AC or AC/DC clamps table)
n Measurement of low, medium or high currents? On small wires or large
cables? … only choose the families with the right shapes and dimensions
Output - Connection technology
n What instrument will the clamp be connected to? (see Output/Connection
column to choose a clamp whose signal and connection technology are
compatible)
Specifications
Measurement input
n Max. AC voltage measurement and choice of installation category:
CAT II or III ? Attenuating probe or differential probe?
n Choice of attenuation: 1/10, 1/100 or 1/1,000 or 1/20, 1/200?
Bandwidth according to the oscilloscope?
n Measurement input impedance
Output- Connection technology
Specific features
n BNC or PROBIX ?
n What are your other criteria? (see the Specific Features column to check
whether the clamp chosen perfectly matches your requirements)
n What are the other criteria? Capacitance, rise time, safety, power supply, etc.
Accessories for multimeters: Connection
Specific features
Specifications
Accessories for multimeters: clamps
AC current measurement
X
AC current measurement with flexible probe
X
AC/DC current measurementX
Leakage current measurement X
Process current measurement X
Pages 98
99
100
101
101
Selection guide on pages 28-29
Choosing your voltage probe
Safety
Leads and test
X
probes ø 4 mm
4 mm banana
connection accessories X
Adapters and probes X
Transport and protection accessories
X
Fuses x
Pages
102
103 102-105106-107
107
Software: see pages 32-33
96
Voltage probes
CAT II voltage probes
X
X
High-voltage probe X
CAT II 300 V voltage probes
X
PROBIX probes for SCOPIX X
Differential probes
Pages 108 109 109 73110-111
Current probes
Measurement with AC/DC clamp
X
X
Measurement with AC clamp
X
Measurement with flexible AC clamp
Pages
112 112113
Connection and protection accessories
BNC X
X
Protection and transport
X
Fuses Pages 114 115116
Software
Scopix-Handscope
Dox
76-77
64
Pages 97
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
ACCESSORIES for MULTIMeterS
ACCESSORIES for MULTIMeterS
MINI 05
5 mA to 10 A
•
MN
MN12
MN08
MN09
MN14
MN89
0.5 A
à 240 A
0.5 A
to 240 A
0.5 A
to 240 A
0.5 A
to 240 A
0.5 A
to 240 A
•
2VAC
•
•
≤3%
≤2%
MA110
3-30-300-3000/3
(25 cm / Ø 7 cm)
P01105105Z
3A
30 A
OFF
≤1%
P01120405
40 Hz … 10 kHz
≤1%
P01120401
1,000/1
40 Hz … 10 kHz
≤1%
P01120402
1 A / 1 mV
40 Hz … 10 kHz
≤1%
P01120416
1 A / 100 mV
40 Hz … 10 kHz
≤2%
P01120415
1 A / 10 mV
40 Hz … 10 kHz
1,000/1
•
•
OL
P
Auto Power Off
On
3 A : 1000 mV
30 A : 100 mV
300 A : 10 mV
3000 A : 1 mV
/A
/A
/A
/A
MA 110
AC CURRENT PROBE
600 V CAT IV
1000 V CAT III
MA110
3-30-300-3000/3
(35 cm / Ø 10 cm)
A110
3-30-300-3000/3
(45 cm / Ø 14 cm)
3A
30 A
300 A
3000 A
OFF
OL
C
C100
0.1 A to 1,200 A
•
C103
0.1 A to 1,200 A
•
C106
0.1 A to 1,200 A
•
C107
0.1 A to 1,200 A
•
•
P
Auto Power Off
On
1,000/1
•
30 Hz … 10 kHz
≤ 0.5 %
P01120301
30 Hz … 10 kHz
≤ 0.5 %
P01120303
1 A / 1 mV
30 Hz … 10 kHz
≤ 0.5 %
P01120304
1 A / 1 mV
30 Hz … 10 kHz
≤ 0.5 %
P01120305
1,000/1
•
•
•
3 A : 1000 mV
30 A : 100 mV
300 A : 10 mV
3000 A : 1 mV
/A
/A
/A
/A
A 110
AC CURRENT PROBE
600 V CAT IV
1000 V CAT III
A110
3-30-300-3000/3
(80 cm / Ø 25 cm)
A110
30-300-3000-30000/3
(120 cm / Ø 38 cm)
0.02 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3000 A
0.02 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3,000 A
0.02 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3,000 A
0.02 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3,000 A
0.02 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3,000 A
0.05 A - 3A
0.5 A .. 30 A
0.5 A .. 300 A
0.5 A .. 3,000 A
•
3 VAC
•
•
3 VAC
•
•
3 VAC
•
•
3 VAC
•
•
3 VAC
•
•
3 VAC
•
1 V/A
100 mV/A
10 mV/A
1 mV/A
1 V/A
100 mV/A
10 mV/A
1 mV/A
1 V/A
100 mV/A
10 mV/A
1 mV/A
1 V/A
100 mV/A
10 mV/A
1 mV/A
1 V/A
100 mV/A
10 mV/A
1 mV/A
100 mV/A
10 mV/A
1 mV/A
0,1 mV/A
•
•
•
•
10 Hz .. 10 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 10 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 10 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 10 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 20 kHz
To order
Typical accuracy
Bandwidth (frequency in Hz)
Power measurement (low phase shift)
Automatic DC zero
Output protected against overvoltages
Specific features
Transformation ratio (input/output)
BNC connector (coaxial)
Female sockets Ø4 mm
Lead + Ø4 mm safety plugs
Voltage
Current
P01105102Z
300 A
•
•
≤1%
Model
MA110
3-30-300-3000/3
(17 cm / Ø 4.5 cm)
3000 A
•
•
48 Hz … 10 Hz
48 Hz … 500 Hz
1 A / 1 mV
•
P01105101Z
Series
Output connections
DC
1 mA / 1 mV
0.1 VAC
1 A to 100 A
≤ 2.5 %
Measurement range
AC
•
10 VAC
48 Hz … 500 Hz
Input
High current
1,000/1
to 100 A
•
Medium current
0.15 AAC
•
BNC connector (coaxial)
•
Female sockets Ø4 mm
1,000/1
•
Lead + Ø4 mm safety plugs
•
Voltage
0.15 AAC
Current
AC
DC
High current
•
To order
50 mA
•
Typical accuracy
MINI 02
2 to 150 A
Bandwidth (frequency in Hz)
Output protected against overvoltages
MINI 01
Medium current
Low current
Model
Transformation ratio (input/output)
MINI
Very low current
Series
Power measurement (low phase shift)
Specific features
Measurement range
Low current
InputOutput
connections
Automatic DC zero
Flexible probes for AC current
Very low current
AC current clamps
≤ 1 % P01120660
≤ 1 % P01120661
≤ 1 % P01120662
≤ 1 % P01120630
10 Hz .. 10 kHz
• 10 Hz .. 20 kHz ≤ 1 % P01120631
10 Hz .. 20 kHz
10 Hz .. 20 kHz
10 Hz .. 10 kHz
10 Hz .. 20 kHz ≤ 1 % P01120632
•
10 Hz .. 20 kHz
10 Hz .. 20 kHz
Standard state at delivery
1 clamp and 1 user manual
Optional accessories
Standard state at delivery
Mains adapter for MA110: PO1651023
USB adapter for A110: PO1651023
mini 05
C103
MN89
MN09
MA 110
98
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
99
ACCESSORIES for MULTIMeterS
ACCESSORIES for multimeters
E6N
•
3 VRMS
5 mA to 2 ADC
5 mA to 1.5 ARMS
0.2 to 40 AAC
0.4 to 60 ADC
0.5 to 600 ADC
PAC 20
PAC 2X
PAC 21
•
•
1.5 VAC
0.5 to 1,000 AAC
0.5 to 1,400 ADC
0.2 to 100 AAC
0.4 to 150 ADC
0.5 to 1,000 AAC
0.5 to 1,400 ADC
DC to 2 kHz
1 A / 10 mV
0.8 VAC/DC
DC to 8 kHz
1A/1V
•
600 mVAC/DC
•
•
0.5 to 600 AAC
1A/1V
•
•
1.4 VAC/DC
•
1 A / 10 mV
•
1.4 VAC/DC
P01120040A
≤4%
C173
≤ 1.5 %
•
DC to 10 kHz
P01120068
≤ 2.5 %
B102
1 A / 1 mV
DC to 5 kHz
P01120071
100 mA to 240 A
•
2 VAC
•
2 VAC
1 A / 1,000 mV
40 Hz to 10 kHz
1 A / 10 mV
To order
Typical accuracy
≤1%
≤2%
1 mA to 1.2 A
1A/1V
≤ 0,7 %
0.01 A to 12 A
10 A / 1 V
≤ 0.3 %
0.1 A to 120 A
1 A to 1,200 A
500 µA to 4 A
0.5 A to 400 A
•
•
1 VAC
10 Hz to 3 kHz
100 A / 1 V
1000 A / 1 V
•
4V
AC
•
0.4 VAC
≤ 0.5 %
P01120421
P01120309
≤ 0.2 %
1 mA / 1 mV
•
1 A / 1 mV
10 Hz to 1 kHz
≤ 0.5 %
≤ 0.35 %
P01120083
P01120069
DC to 10 kHz
≤ 2.5 %
1 A / 1 mV
Measurement of process current
4.5 VDC
1 mA to 4.5 ADC
≤ 1.5 %
•
•
≤2%
* Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the K Series
K1
1 mA to 3 ARMS
1 mA to 4.5 A crête
• •
3 VRMS
•
DC to 2 kHz
1 mA / 1 mV
≤ 1% P01120067A
4.5 V crête
Delivered with 9 V battery and user manual
* Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the K Series
Barre 63 x 5 mm max.
PAC 2x
224 mm
2 x 24 mm
ou Ø 30 mm
Câble Ø = 30 mm maxi
2 câbles
Ø = 25 mm maxi
I
97 mm
K2
Standard state at delivery
Bandwidth (frequency in Hz)
Output protected against overvoltages
Automatic DC zero
Power measurement (low phase shift)
Automatic DC zero
Lead + Ø4 mm safety plugs*
Transformation ratio (input/output)
BNC connector (coaxial)
Voltage
Current
AC
DC
High current
Medium current
Low current
10 mA to 2.4 A
Delivered with user manual
•
1 A / 10 mV
•
≤2%
Specific features
Leakage current measurement
MN73
2 VDC
CVery low current
P01120074A
Model
≤1%
Series
Automatic DC zero
DC to 1.5 kHz
4.5 V crête
20 mA to 80 AAC/DC
PAC 1X PAC 11
To order
•
0.1 to 450 mA crête
E
1 mA / 10 mV
4.5 VDC
0.1 to 300 mARMS
•
Typical accuracy
K2
Bandwidth (frequency in Hz)
K
Transformation ratio (input/output)
0.1 to 450 mADC
Lead + Ø4 mm safety plugs*
Voltage
Current
DC
Model
Low current
Series
AC
Input
Output
Measurement range
connections
High current
Input
Output
Specific features
Measurement range
connections
Medium current
Current clamps for specific requirements
Very low current
AC/DC current clamps
195 mm
PAC11
Delivered with 9 V battery and user manual
Optional accessories
100
Mains adapter for K: P01101966
Mains adapter for E: P01101965
Mains adapter for PAC: P0110196
PAC20
E6N
Detailed product brochures can be downloaded free of charge from www.metrix.fr
66 mm
www.metrix.fr
34 mm
101
ACCESSORIES for MULTIMeTerS
ACCESSORIES for multimeters
Leads and accessories
Ø 4 mm banana connection accessories
Other accessories
Removable test probes
For CAT IV & CAT III installations
For CAT IV & CAT III installations
Set of 2 moulded test probes
Female plug Ø 4 mm 15 A- CAT IV and CAT III
> P01295454Z
1,000 V For CAT II and lower installations
Set of 2 moulded test probes Ø 4 mm
Female plug Ø 4 mm 15 A - CAT II 300 V
> P01295458Z
For CAT II and lower installations
Set of 2 moulded test probes Ø 2 mm
Female plug Ø 4 mm 15 A - CAT II 300 V
> P01295460Z
Moulded measurement leads
Set of 2 moulded PVC leads (R/B)
Insulated straight male plug Ø 4 mm - Insulated
straight male plug Ø 4 mm 15 A, 1.5 m - 1,000 V
> P01295450Z
CAT IV
Set of 2 moulded PVC leads (R/B)
Insulated straight male plug Ø 4 mm - Insulated
elbowed male plug Ø 4 mm 15 A, 1.5 m
> P01295451Z
Set of 2 moulded silicone leads (R/B)
Insulated straight male plug Ø 4 mm - Insulated
straight male plug Ø 4 mm 15 A, 1.5 m - 1,000 V
> P01295452Z
CAT IV
Set of 2 moulded silicone leads (R/B)
Insulated straight male plug Ø 4 mm - Insulated
elbowed male plug Ø 4 mm 15 A, 1.5 m
> P01295453Z
1,000 V CAT IV Set of 2 IP2X PVC leads for multimeter
Compliant with NF C 18-510 and IEC 61010031+A1:2008 IP2X test probe - Insulated elbowed
male plug Ø 4 mm 15 A, 1.5 m - 600 V CAT IV
> P01295461Z
Set of 2 red/black crocodile clips
15 A - 1,000 V CAT IV Set of 2 PVC leads (R/B)
Insulated straight male plug Ø 4 mm - Insulated
elbowed male plug Ø 4 mm 15 A, 1.5 m - 600 V
> P01295289Z
CAT IV / 1,000 V CAT III Set of 2 PVC leads (R/B). Insulated straight male
plug Ø 4 mm with rear connection - Insulated
straight male plug Ø 4 mm with rear connection
> P01295290Z
20 A, 2 m - 600 V CAT III Built-in test-probe leads
Set of 2 PVC test-probe leads (R/B)
Insulated straight male plug Ø 4 mm 15 A,
1.5 m - 1,000 V CAT IV > P01295455Z
Set of 2 PVC test-probe leads (R/B)
Insulated elbowed male plug Ø 4 mm 15 A,
PVC 1.5 m - 1,000 V CAT IV > P01295456Z
PVC lead
Insulated male BNC - Insulated straight male plugs
(R/B) Ø 4 mm with rear connection 1 m
> AG-1066Z
- 500 V CAT III Set of leads and measurement accessories
for electricians comprising:
- 1 set of 2 moulded test probes CAT IV
1,000 V - 1 set of 2 moulded PVC leads (R/B)
straight male plug - elbowed male plug 1.5 m 1,000 V
CAT IV - 1 set of 2 crocodile clips (R/B) 1,000 V
CAT IV - 1 set of 2 moulded test probes Ø 4 mm
> P01295459Z
- 300 V CAT II Set of leads and measurement accessories for
electricians
2 x moulded test probes 1,000 V CAT IV
- 2 red/black moulded PVC leads with straight
male plug – elbowed male plug 1.5 m 1,000 V
CAT IV - 2 red/black crocodile clips 1,000 V
CAT IV - 2 x moulded test probes Ø 4 mm
> P01295459Z
- 300 V CAT II Set of 2 adapters
insulated female BNC - Insulated male plugs
(R/B) Ø 4 mm with 19 mm spacing
> P01102101Z
600 V CAT III Kit with 2 PVC leads
+ 2 test probes Ø4 mm - Straight male plug
Ø4 mm - Elbowed male plug Ø4 mm
- Test probe Ø 4 mm - Female plug Ø 4 mm
> P01295475Z
- CAT II 300V Set of 2 red/black magnetized test probes
For voltage measurement only, test probe Ø
6.6 mm – Elbowed female plug Ø 4 mm
- 1,000 V CAT III / 600 V CAT IV
> P01103058Z
Set of 2 red/black crocodile wire grips
20 A - 1,000 V CAT III > P01102053Z
Set of 2 adapters - Insulated female BNC plug –
Insulated red/black male plugs Ø 4 mm with
19 mm spacing - 600 V CAT III
> P01102101Z
> P01295457Z
Set of 2 croc. wire grips (R/B) 20 A
1,000 V CAT III > P01102053Z
> P01295457Z
Standard measurement leads
Set of 2 PVC leads (R/B)
Insulated straight male plug Ø 4 mm -Insulated
straight male plug Ø 4 mm 15 A, 1.5 m - 600 V
> P01295288Z
CAT IV / 1,000 V CAT III Set of 2 crocodile clips (R/B) 15 A
1,000 V CAT IV For CAT II and lower installations
Set of 2 adapters
Insulated male BNC - Insulated female plugs
(R/B) Ø 4 mm with 19 mm spacing
> HX0107
600 V CAT III Set of 2 insulation-piercing clips (R/B) 30 Vac,
60 Vdc
> P01102055Z
Current lead equipped with a French 2P+E
power socket
For inserting an ammeter in series and
in total safety to measure current with a current
clamp without removing the external sheath of the
> P03295509
power supply cable Measurement lead for French and German 2P+E
power sockets
For direct measurement on a mains socket
Quick implementation and reliable connections
> P06239307
Set of 2 adapters
Male BNC - insulated female sockets (R/B) Ø 4 mm
with 19 mm spacing - 500 V CAT I, 150 V CAT III
> P01101846
Set of 2 adapters
Male BNC - Insulated male sockets (R/B)
Ø 4 mm with 19 mm spacing
> P01101847
500 V CAT I, 150 V CAT III CMS clamp
Copper-Gold-plated Beryllium contacts - Output via
male plugs Ø 4 mm - Length 1.20 m - SELV
> HX0064
Temperature measurement
Adapters
Set of 2 thermocouple safety adapters
for multimeters
Female thermocouple plug - Insulated male plugs
(R/B) Ø 4 mm with 19 mm spacing > P01102106Z
Pt100/Pt1,000 probe adapter for multimeters
Female Pt100/Pt1,000 plug - Insulated male plugs
(R/B) Ø 4 mm > HX0091
Safety adapter and K-sensor temperature probe
- For multimeters and multimeter clamps equipped
with a temperature measurement calibre with
banana inputs with 19 mm spacing
- Measurement range from –50 °C to +350 °C
> P01102107Z
Kit of 2 PVC leads + 2 test probes
Ø 2 mm - Straight male plug Ø 4 mm - Elbowed
male plug Ø 4 mm - Test probe Ø 2 mm - Female
> P01295474Z
plug Ø 4 mm - 300 V CAT II PVC lead
Insulated male BNC plug – Insulated straight male
banana plugs Ø 4 mm (red/black)with rear
> AG-1066Z
connection - 1 m - 500 V CAT III 102
103
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
ACCESSORIES for MULTIMeTerS
ACCESSORIES for multimeters
Physical measurement
K thermocouple sensors
Pt100 platinum probes
Thermocouple technology
Pt100 Ω technology
The sensor is formed by the thermocouple measurement
junction at its hot point. The reading is taken at its cold
junction, which requires compensation to simulate the point
at 0 °C.
The relation between the resistance and the temperature,
like the tolerances, is defined in the IEC 751 European
standards.
Various materials
thermocouples.
• platinum-wire resistors wound around an insulating
support
are
used
to
manufacture
2 different technologies are used:
these
The thermo-electric forces and tolerances are defined in the
IEC 584 standard.
• ceramic substrate coated with a platinum film
IEC 751 correspondence table (extracts): temperature and resistance
°C Ω
°C
Ω
°C
Ω
EIT 90 EIT 90 EIT 90
200 18.52 50 119.4 400 247.09
-100 60.26 100 138.51 600 313.71
0 100 200175.40 850 390.48
IEC 584 correspondence table (extracts): temperature and voltage
°C mV
°C
mV
°C
mV
EIT 584 EIT 584
EIT 584
-40 1.527 50 2.023 600 24.905
0
0 100 4.0961,00041.276
200 8.138 1,20048.838
Tolerance class - The IEC 751 standard defines the interchangeability
tolerances as follows:
Interchangeability tolerance according to NF EN 60584-2
Class 1
-40 °C to +375 °C: ±1.5 °C
+375 °C to +1,000 °C: ±0.004 x t °C
Tolerance class
A
B
Class 2
-40 °C to +333 °C: ±2.5 °C
+333 °C to +1,200 °C: ±0.0075 x t °C
Tolerance
0.15 + 0.0025 x [t]
0.3 + 0.005 x [t]
[t] is the absolute value of the temperature in °C
where t is the temperature in °C
Model Measurement range
Response time
Diameter
Length
Description
K thermocouple sensors
SK1 needle
-50 to +800 °C
1 s
3 mm15 cm
For penetration into pasty, viscous products
SK2 bendable -50 to +1,000 °C
2 s
2 mm1 m
Can be bent as required
SK3 semi-rigid -50 to +1,000 °C
6 s
4 mm50 cm
Can be bent slightly
SK4 surface
0 to +250 °C
1 s
5 mm15 cm
Adapted for measurements on small surfaces
8 mm Ø spring tip ensuring optimum contact
SK5 surface
-50 to +500 °C
1 s
5 mm
15 cm
even if the sensor is not placed at right angles
1 s by contact
1 mm
1 m
Recommended for points where access is difficult
SK6 flexible
-50 to +285 °C
3 s in ambient air
For measurements of ambient air.
SK7 air
-50 to +250 °C
5 s
5 mm
15 cm
Thermocouple protected by a metal sheath Ø 8.5 mm
10 s on stainless
For pipes
The thermocouple placed on a sheet of copper, at the end of a double
SK8 auto-grip
-50 to +140 °C
steel pipe (Ø 12 mm) 10 mm ≤ Ø ≤ 90 mm sided Velcro ribbon, is held in contact by winding the ribbon round the pipe
SK11 needle
-50 to +600 °C
12 s
3 mm
13 cm
For penetration into pasty, viscous products
SK13
-50 to +1,100 °C
12 s
3 mm
30 cm
All uses
general use
SK14
Surface temperature for difficult access. Tip Ø 15 x 30 mm
-50 to +450 °C
8 s
6 mm
13 cm
surface-elbowed
SK15 surface
-50 to +900 °C
2 s
8 mm
13 cm
Tip Ø 8 mm with spring, ensuring optimum contact
SK17 air
-50 to +600 °C
3 s
6 mm
13 cm
For ambient air measurements
SK19 surface
-50 to +200 °C
7 s
14 mm
12 mm
Fixed by magnet
with magnet
Model Measurement Pt100 platinum probes
Response Diameter
Length
SP 10 -50 to +200 °C
6 s
5 mm
Needle 13 cm
SP 11
-100 to +600 °C
7 s
3 mm
Needle 13 cm
SP 12
-100 to +600 °C
5 s
5 mm
Needle 13 cm
SP 13
-100 to +600 °C
7 s
3 mm
Needle 13 cm
Description
For flat surfaces. The spring ensures optimum contact,
even if the sensor is not set up perpendicularly.
For penetration (20 mm minimum)
in pasty and viscous products.
Suitable for all ambient air measurements (moving air).
If the air is “stationary”, agitate the sensor.
Specially designed for liquids
References to order
104
P03652901 : SK 1
P03652902 : SK 2
P03652903 : SK 3
P03652904 : SK 4
P03652905 : SK 5
P03652906 : SK 6
P03652907 : SK 7
P03652908 : SK 8
P03652917 : SK 11
P03652918 : SK 13
P03652919 : SK 14
P03652920 : SK 15
P03652921 : SK 17
P03652922 : SK 19
P03652909: CK 1
P03652910: CK 2
P03652913: CK 3
P03652914: CK 4
Detailed product brochures can be downloaded free of charge from www.metrix.fr
References to order
P03652712: SP 10
P03652713: SP 11
www.metrix.fr
P03652714: SP 12
P03652715: SP 13
HX0091 : Banana plug / Pt100 connector
adapter
105
ACCESSORIES for MULTIMeTerS
ACCESSORIES for multimeters
General-purpose transport
and protection accessories
Metal cases
Equipped with foam inserts and delivered with strap and keys
Dimensions
270 x 195 x 65 mm
320 x 255 x 75 mm
440 x 310 x 135 mm
MC 0160B
References
P01298071
P01298004
P01298072
AE 0237
MC 0160B + MC 0159B
P01298072
HX0052
P01298071
For MX Concept series : MX 21, MX 22, MX23, MX 24, MX 24B, MX 26
AE0237
HX0010
AE0190
HX0009
HX0018
Sheath (not MX 26)
Sheath for MX 26
Soft case Hard case
Transport soft case
P01298004
For ASYC II series : MX 20, MX 44, MX 5x
MC0160B
MC0159B
AE0227
AE0193
Sheath Handle Hard case Soft case All-terrain waterproof site cases
For MTX series : MTX 3281, MTX 3282, MTX 3283
Soft case Equipped with foam inserts
HX0052
For analogue multimeters
Soft case Hard case AE0216
AE0228
Dimensions
For ASYC IV multimeters
Soft case: MTX 3290 and MTX 3291 Soft case: MTX 3292 and MTX 3293 References
272 x 248 x 130 mm
272 x 248 x 182 mm
HX0052 B
HX0052C
MTX329X bag
P01298069
P01298068
106
Detailed product brochures can be downloaded free of charge from www.metrix.fr
P01298068
P01298069
www.metrix.fr
107
ACCESSORIES for oscilloscopes
ACCESSORIES for oscilloscopes
Electronic voltage probes
HX0003, HX0004, HX0005, HX0006 & HX0108
High-voltage / high-frequency probe
HX0027
n A family of 5 products to cover all types of
requirements
n Design mounted on a patented ceramic support, with the
elements adjusted by laser
n Attenuation ratio of 10 or 100 (depending on the
model)
n Interchangeable spring-mounted tip
n Bandwidth from 150 MHz to 300 MHz
n This 14kV high-voltage probe can be used in various sectors:
n 1/1,000 probe with 30 MHz bandwidth
n EN61010 safety from 400 V CAT II to 1,000 V CAT III
(depending on the model)
- automotive inrush
- radar pulse measurement
n Compensation range from 12 to 22 pF or from 12 to
25 pF (depending on the model)
- motor control
- transformers
n Connection accessories are available for the probes:
- s witching systems in electrical engineering and power
electronics
- HX0007: hook-type wire-grip termination
- HX0008: crocodile-type wire-grip termination
- pulsed discharge lighting equipment (Xenon lamps)
n Additional accessories are delivered with the
HANDSCOPE HX0108 kit
- drilling systems in the oil industry
- railway sector
ISOPROBE III probe compliant with 600 V CAT III
with 1/10 attenuation on a 500 MHz bandwidth +
HX0107 BNC /BAN adapter
General-purpose probes
HX0206,
HX0210 & HX0220
Specifications
HX0003 HX0004HX0005HX0006
HX0108
Attenuation
1:10 1:10 1:101:100 1:10
Bandwidth
150 250450300 500
Input impedance (MΩ)
10 ±1 %
10 ±1 %
10 ±1 %
100 ±1 %
10 ±1 %
Capacitance (pF)
14
14
< 14
≤ 6
12
Rise time (ns)1.2
≤ 1.2
≤ 1
< 1
0.9
EN61010-2-031 safety
400 V CAT II
1,000 V CAT II
1,000 V CAT II
1,000 V CAT II
600 V CAT III
max 5 kV peak
Compensation range (pF)
12 to 25
12 to 25
12 to 25
12 to 22
10 to 22
Retractable safety sleeve
Grey BlueVioletRed
Grey
Standard state at delivery
References to order
n Attenuation with a switchable ratio of 1:1 or 10:1
n 60 MHz, 100 MHz or 200 MHz depending on the model
Specifications
Attenuation
Bandwidth
Input impedance (MW)
Capacitance (pF)
Rise time (ns)
EN61010-2-031 safety
Compensation range (pF)
HX0027 HX0206HX0210 HX0220
1:1,000
1:1 1:10 1:11:10 1:11:10
30
15 60 15 100 15200
100+-1 %
1
10
1
10
1
10
< 2.5
45
15
46
15
45
11
< 12
23
6
23
3.5
35
1.7
14 kV max 40 kV peak
300 V CAT II
300 V CAT II 300 V CAT II 300 V CAT II
300 V CAT II 300 V CAT II
10 to 50
-
10 to 50
-
10 to 50
-
10 to 35
HXxxxx: 1 probe, 1 reference lead,
1 user manual
108
HX0003: Compact 10:1 probe, 150 MHz
HX0004: Compact 10:1 probe, 250 MHz
HX0005: Compact 10:1 probe, 450 MHz
HX0006: Compact 100:1 probe, 300 MHz
Accessories for HXOOOx
HX0108: Measurement kit comprising 1 compact 10:1 probe
HX0007: Hook-type wire-grip termination - 500 MHz 600 V CAT III, and one BNC/Banana ø 4 mm
HX0008: Crocodile wire-grip termination adapter (HX0107)
n A family of 3 products for general-purpose requirements
Detailed product brochures can be downloaded free of charge from www.metrix.fr
HX0108 kit
Standard state at delivery
HX0027: 1 probe, 1 "hook" measurement termination, 1 crocodile clip, 1 screwdriver for adjustment, 1 user manual, 1 hard case
HX0206-HX0210-HX0220: 1 probe, 1 "hook" measurement termination, 1 crocodile measurement earth, 1 screwdriver for adjustment,
1 user manual
www.metrix.fr
109
ACCESSORIES for oscilloscopes
ACCESSORIES for oscilloscopes
Differential voltage probes
MX 9030, MTX 1032-B & MTX 1032-C
Ideal accessories for analogue or digital oscilloscopes
for viewing signals not referenced to the earth, the MTX
1032-B and MTX 1032-C are equipped with 2 differential
channels.
Powered by the mains supply, these probes can be used
separately or hooked up to MTX Compact oscilloscopes.
The MX 9030 probe is supplied in a stand-alone handheld casing and is powered by a battery.
n A family of 3 products to meet
the various requirements
n 1 or 2 input channels, 30 MHz or
50 MHz bandwidth
Specifications
MX 9030-Z
MTX 1032-B
MTX 1032-C
Diff. input voltage
±60 V or ±600 V
±40 V or ±400 V
Max. Voltage in ±600 V
common mode
Attenuation / Accuracy
1/20 and 1/200 - ±3 %
1/10 and 1/100 - ±3 %
Bandwidth 30 MHz
30 MHz
50 MHz
Rise time
11.7 ns
11.7 ns
7 ns
Output impedance
50 Ω
Coaxial output
± 3 V with 1 MΩ load
± 4 V with 1 MΩ load
voltage (max.)
Noise level
< 10 mVpp
General specifications
Power supply
9 V battery Mains: 230 Vac ±10 % 50/60 Hz
Safety
IEC 61010-1
IEC 61010-1
IEC 61010-1
600 V CAT IV
600 V CAT III
600 V CAT II
Dimensions / Weight
163 x 62 x 40 mm / 195 g (with battery)
270 x 250 x 63 mm / 1.2 kg
n Extra-long banana or coaxial/
banana measurement leads
n Supplied in a laboratory casing or
handheld casing with wrist-strap
MTX 112U:
built-in double differential probe
Use of differential probes with a Class 1 oscilloscope protected by the earth
Line
Neutral
Earth
Differential probes
Phase 1
Standard state at delivery
References to order
MX9030-Z: 1 single-channel probe with output on BNC cable, 1 standard battery
installed, 1 set of PVC banana leads 1.10 m long, 1 set of 2 industrial-grade crocodile
clips, 1 user manual
MTX1032-B: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long,
2 sets of PVC banana leads 1.10 m long, 1 European mains power cable, 1 set of
accessories for mounting the probe on the oscilloscope, 1 user manual
MTX1032-C: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long,
1 set of 2 BNC-banana cables 2 m long, 2 crocodile wire-grips for probes, 1 European
mains power cable, 1 set of accessories for mounting the probe on the oscilloscope,
1 user manual
MX9030-Z: 1 x 30 MHz stand-alone
differential probe
MTX1032-B: 2 x 30 MHz differential probe
with banana inputs
MTX1032-BRK: MTX1032-B rack version
MTX1032-C: 2 x 50 MHz differential;
probe with coaxial inputs
MTX1032-CRK: MTX1032-C rack version
Available accessories
See pages 110 to 118
Phase 2
110
111
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
For further details…
ACCESSORIES for oscilloscopes
ACCESSORIES for oscilloscopes
Insulated current probes
AC/DC current probes
Specifications
Measurement range
Transformation ratio
Flexible current probes
HX0102
E3N
PAC12
PAC22
3 mA to 20 Aac/dc
50 mA to 100 Aac/dc
200 mA to 600 Aac/dc
200 mA to 1,400 Aac/dc
10 mV/A - 1 mV/A
100 mV/A
100 mV/A - 10 mV/A
10 mV/A - 1 mV/A
DC to 60 kHz
DC to 100 kHz
DC to 10 kHz
DC to 10 kHz
< 1.5 %
<3%
< 1.5 %
≤ 1.5 % and ≤ 2 %
30 mA to 20 Aac/dc
100 mVdc/A
-
-
-
Clamping diameter
11.8 mm
11.8 mm
30 mm
42 mm
Output connector
BNC
BNC
BNC
BNC
Cable length
2m
2m
2m
2m
Dimensions
231 x 67 x 36 mm
231 x 67 x 36 mm
224 x 97 x 44 mm
236.5 x 97 x 44 mm
Bandwidth
Accuracy
RMS analogue output
Weight
330 g
330 g
440 g
520 g
Power supply
1x9V
1x9V
1x9V
1x9V
Safety
CEI 61010-2-032 - 300 V CAT IV / 600 V CAT III
Accessories supplied
To order
1 x 9 V battery and user manual
HX0102
HX0102-K*
P01120043A
P01120047*
P01120072
P01120073
AC current probes
Specifications
MN 60
Specifications
Y7N
C160
D38N
Measurement range
0.1 to 60 A peak AC 1 A to 1,200 A peak
0.1 to 2,000 A peak
1 A to 5,000 A peak
and 0.5 to 600 A peak AC
Transformation ratio
100 mV - 10 mV/A
1 mV / A
100 mV/A – 10 mV/A – 1 mV/A –
10 mV/A – 1 mV/A
0.1 mV/A
Bandwidth
40 Hz to 40 kHz
5 Hz to 10 kHz
10 Hz to 100 kHz
30 Hz to 50 kHz
Accuracy
≤ 2 % and ≤ 1.5 %
≤ 2 %
≤ 3 %, ≤ 2 %, ≤ 1 %
≤2%
Clamping diameter
20 mm
30 mm
52 mm
64 mm
Output connector BNC BNCBNCBNC
Cable length
2 m
2m
2 m
2m
Dimensions
135 x 51 x 30 mm
195 x 66 x 34 mm
216 x 111 x 45 mm
305 x 120 x 48 mm
Weight
180 g 420 g 550 g
1,200 g
IEC 61010-2-32 safety
300 V CAT IV / 600 V CAT III
Accessories supplied
1 user manual
To order
P01120409
P01120075
P01120308
P01120057A
MA200MA200 MA200
30-300/3 – (17 cm)
Measurement range 0.5 to 45 Apeak
0.5 to 450 Apeak
Transformation ratio 100 mV/A - 10 mV/A
Bandwidth 5 Hz to 1 MHz
Accuracy ≤ 1 % +0.3 A
Clamping diameter 45 mm
Output connector BNC
Cable length 2 m + 40 cm
Dimensions 140 x 64 x 28 mm
Weight 200 g
Power supply 1 x 9 V
IEC 61010-2-32 safety 600 V CAT IV
1,000 V CAT III Accessories supplied
To order
P01120570
30-300/3 – (25 cm)
0.5 to 45 Apeak
0.5 to 450 Apeak
100 mV/A - 10 mV/A
5 Hz to 1 MHz
≤ 1 % +0.3 A
70 mm
BNC
2 m + 40 cm
140 x 64 x 28 mm
200 g
1 x 9 V
600 V CAT IV
1,000 V CAT III 1 x 9 V battery and 1 user manual
P01120571
3000/3 – (35 cm)
5 A to 4,500 Apeak
1 mV/A
5 Hz to 1 MHz
≤ 1 % +0.3 A
100 mm
BNC
2 m + 40 cm
140 x 64 x 28 mm
200 g
1x9V
600 V CAT IV
1,000 V CAT III
P01120572
Optional accessory
Mains adapter for MA200: P01102087
112
113
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
For further details…
ACCESSORIES for oscilloscopes
ACCESSORIES for oscilloscopes
Coaxial cables
Coaxial cables
Safety leads with 50 Ω impedance, length 1 m- IEC 61010-2-031 Cat. III 500 V, black:
insulated male BNC / banana plugs with rear connection
> AG1066-Z (2 p)
Safety leads with 50 Ω impedance,
length 1 m IEC61010-2-031 - 600 V CAT III, black Protection and transport accessories
and mechanical adaptations
For oscilloscopes
> HX0106 (2 p)
Earth safety leads, length 2 m, O 4 mm banana connection
- IEC 61010-2-031 Cat. III 1,000 V:
Female banana plug / female, yellow/green (earth)
> P01295073A (5 p)
MTX-family bag for MTX 3240, MTX 3250,
MTX 3252, MTX 3352 and MTX 3354 models.
The mouse can be stored in the side pocket.
Accessories
Set of 2 adapters
Insulated male BNC plug - insulated female plugs (R/B) Ø 4 mm with 19 mm spacing
600 V CAT III > HX0107
> HX0024
Empty hard case for Scopix equipped with precut foam inserts for stowing documents and
accessories (power supply, Probix accessories,
communication cables, etc.).
Set of 2 adapters
Insulated female BNC - Insulated plugs (RIN) ø 4 mm with 19 mm spacing - 600 V CAT III > P01102101Z
> HX0038
Set of 2 adapters
Male BNC -insulated female sockets (R/B) Ø 4 mm with 19 mm spacing
500 V CAT I, 150 V CAT III > P01101846
Set of 2 adapters
Male BNC - insulated male sockets (R/B) Ø 4 mm with 19 mm spacing
500 V CAT I, 150 V CAT III > P01101847
Load adapter
50 Ω BNC additional load > PA4119-50 (1 p)
Rack for safety leads (1 rack)
Rack for hanging 60 leads > P01101914 (1 p)
Scopix case equipped with 1/10 Probix
HX0030(A) probe, HX0031 BNC Probix
adapter, HX0039 straight Ethernet cable,
SX-METRO/P software.
> HX0057
Insulated T-joint IEC 61010-2-031 - 500 V CAT I
1 insulated male BNC / 2 female BNC The instruments in the MTX 1052, MTX 1054
and MTX 1032 Series are available in versions
equipped with a standard 19’’ rack.
> HA2004-Z (3 p)
> PACK 19
Insulated extension IEC 61010-2-031 - 500 V CAT I
Female BNC / female BNC > HA2005 (1 p)
Safety coupling jumper with 19 mm spacing - Ø 4 mm - 36 A
- IEC 61010-2-031:
Set of 10 black coupling jumpers > P01101892A
Protective hands-free bag
for HANDSCOPE portable
oscilloscopes (OX5022 and
OX5042).
> HX0105
114
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
115
ACCESSORIES for oscilloscopes
index by product
Fuse selection table
ProductDescription
Product Standardized Sales
Amperage
concerneddimensions reference
AX 501
5 x 20
AX 502 5 x 20
AX 503
5 x 20
MTX 3240
5 x 20
MTX 3250
6 x 32
MTX 3281
10 x 38
MTX 3282. MTX 3292
10 x 38
MTX 3283. MTX 3293
10 x 38
MX 1
6 x 32
MX 1
6 x 32
MX 2B
6 x 32
MX 2B
6 x 32
MX 20
8 x 32
MX 20
5 x 20
MX 20HD
6 x 32
MX 20HD
5 x 20
MX 22
6 x 32
MX 22
6 x 32
MX 23
6 x 32
MX 24B
6 x 32
MX 24B
6 x 32
MX 26
6 x 32
MX 26
6 x 32
MX 35D
6 x 32
MX 35D
5 x 20
MX 430
10 x 38
MX 430
5 x 20
MX 44
6 x 32
MX 44
5 x 22
MX 44HD
6 x 32
MX 44HD
5 x 20
MX 51
8 x 32
MX 51
5 x 20
MX 52
8 x 32
MX 52
5 x 20
MX 53
6 x 32
MX 53
5 x 20
MX 54C
6 x 32
MX 54C
5 x 20
MX 553. MX 5006
6 x 32
MX 556. MX 5060
6 x 32
MX 55C
6 x 32
MX 55C
5 x 20
MX 56C
6 x 32
MX 56C
5 x 20
MX 573
5 x 20
MX 573
10 x 38
MX 57EX
MX 57EX
MX 58HD
10 x 38
MX 58HD
5 x 20
MX 59HD
10 x 38
MX 59HD
5 x 20
OX 530
5 x 20
OX 803B
5 x 20
OX 832
5 x 20
OX 836B
5 x 20
3.15 A
3.15 A
3.15 A
0.315 A
10 A
11 A 11 A
11 A
10 A
1.6 A
10 A
1.6 A
10 A
0.63 A
10 A
0.63 A
10 A
0.63 A
10 A
10 A
0.63 A
10 A
0.63 A
10 A
3.15 A
10 A
0.16 A
10 A
0.63 A
10 A
0.63 A
10 A
0.63 A
10 A
0.63 A
10 A
0.63 A
10 A
0.63 A
10 A
10 A
10 A
0.63 A
10 A
0.63 A
2 A
10 A
1 A
0.5 A
11 A
0.63 A
11 A
0.63 A
2.5 A
2.5 A
0.315 A
2.5 A
AT0069
AT0069
AT0069
P01297074
AT0095
P01297092
P01297092
P01297092
AT0070
AT0071
AT0070
AT0071
AT0055
AT0094
AT0095
AT0094
AT0095
AT0519
AT0095
AT0095
AT0519
AT0095
AT0519
AT0070
AT0053
P01100731
P03297508
AT0095
AT0518
AT0095
AT0518
AT0055
AT0094
AT0055
AT0094
AT0095
AT0518
AT0095
AT0518
AT0095
AT0095
AT0095
AT0518
AT0095
AT0518
AA0921
P01100731
AT0064
AT0057
P01297092
AT0518
P01297092
AT0518
AT0090
AT0090
P01297074
AT0090
116
Page
A
A110
A130
AmpFLEX®
AX 1360-P
AX 501
AX 502
AX 503
Flexible AC current sensor
Flexible AC current sensor
Flexible AC current sensor
Laboratory power supply
Laboratory power supply
Laboratory power supply
Laboratory power supply
99
99
29
90 - 92
90 - 91
90 - 91
90 - 91
B
B102
Leakage current clamp
101
C
C100
C103
C106
C107
C160
C173
CX 1651
AC current clamp
AC current clamp
AC current clamp
AC current clamp
AC current probe
Leakage current clamp
Multi-function calibrator
98
98
29 - 98
29 - 98
112
101
94 - 95
D
D38N
DOX 2025
DOX 2040
DOX 2100
DOX 3104
DOX 3304
AC current probe
Laboratory digital oscilloscope
Laboratory digital oscilloscope
Laboratory digital oscilloscope
Laboratory digital oscilloscope
Laboratory digital oscilloscope
112
57 - 60 - 61
57 - 60 - 61
57 - 60 - 61
57 - 62 - 63 - 85
57 - 62 - 63 - 85
Insulated AC/DC current probe
AC/DC current clamp
112
28 - 29 - 100
E
E3N
E6N G
GX
GX
GX
GX
GX
1025
1050
305
310
320
Arbitrary function generator
Arbitrary function generator
Low-frequency generator
Low-frequency generator
Low-frequency generator
85 - 88 - 89
85 - 88 - 89
85 to 87
85 to 87
85 to 87
H
HX 0059
HX0003
HX0004
HX0005
HX0006
HX0027
HX0082
HX0083
HX0102
HX0108
HX0206
HX0210
HX0220
Software for multimeters
Electronic voltage probe
Electronic voltage probe
Electronic voltage probe
Electronic voltage probe
High-voltage - high-frequency probe
Near-field probe
Near-field probe
Insulated AC/DC Electronic voltage probe
General-purpose probe
General-purpose probe
General-purpose probe
33
108
108
108
108
109
82
82
112
108
109
109
109
K
K1
K2 Process current clamp AC/DC current clamp
101
28 - 29 - 100
M
MA110
MA130
MA200
MINI01
MINI02 MINI03 MINI04 MINI05
MINI06 MINI07
MINI08 MINI09
MiniFLEX®
MN08
MN09
MN12
MN14
MN60
Flexible AC current clamp
Flexible AC current clamp
Flexible current clamp
AC current clamp AC current clamp Current clamp
Current clamp
AC current clamp Current clamp
Current clamp
Current clamp
Current clamp
Flexible current clamp
AC current clamp AC current clamp AC current clamp Current clamp
AC current probe
28 - 29 28 - 29 -
29 29 -
99
99
115
98
98
28
28
98
28
28
28
28
29
98
98
98
98
112
117
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
index by product
index by function
ProductDescription
Page
ProductPage
ProductPage
MN71
Current clamp
MN73 Leakage current clamp
MN89
AC current clamp
MTX 1050
Spectrum analyser
MTX 1052
Screenless digital oscilloscope
MTX 1054
Screenless digital oscilloscope
MTX 112
Screenless digital oscilloscope
MTX 162
Screenless digital oscilloscope
MTX 202
On-site digital multimeter
MTX 203
On-site digital multimeter
MTX 3290
ASYC IV digital multimeter
MTX 3291
ASYC IV digital multimeter
MTX 3292
ASYC IV digital multimeter
MTX 3293
ASYC IV digital multimeter
MTX1032-B
Differential voltage probe
MTX1032-C
Differential voltage probe
MX 1
On-site analogue multimeter
MX 125Voltmeter
MX 135
Ammeter MX 24
On-site digital multimeter
MX 24B
On-site digital multimeter
MX 26
On-site digital multimeter
MX 2B
On-site digital multimeter
MX 350
Multimeter clamp
MX 355
Multimeter clamp
MX 406B
Analogue insulation tester
MX 407
Insulation tester
MX 435D
Multi-function installation tester
MX 5006
Benchtop multimeter
MX 5060
Benchtop multimeter
MX 57Ex
Multimeter for difficult environments
MX 57EX-CAL Software for multimeters
MX 604
Insulation tester
MX 650
Multimeter clamp
MX 655
Multimeter clamp
MX 670
Multimeter clamp
MX 675
Multimeter clamp
MX 9030
Differential voltage probe
MX 98
Cos-phi meter
28 - 29
28 - 29 - 101
29 - 98
80 to 82
49 to 51 - 54 - 55
49 to 51 - 54 - 55
49 - 51 - 53
49 - 51 -52
15 - 16 - 17
15 - 16 - 17
15 - 22 to 25
15 - 22 to 25
15 - 22 - 23 - 26 - 27
15 - 22 - 23 - 26 - 27
110
110
8 & 13
45
45
15 - 18- 19
15 - 18- 19
15 - 18- 19
8 & 13
35 - 36
35 - 36
42
43
44
15 - 30 - 31
15 - 30 - 31
15 - 20 - 21
33
42
35 - 37
35 - 37
35 - 38
35 - 38
110
40
A
M
65 to 67
65 to 67
49 - 56
57 to 59
57 to 59
65 - 68 - 69 - 70
65 - 68 - 69 - 71
49 - 56
65 - 68 - 69 - 71
65 - 68 - 69 - 70 - 71
65 - 68 - 69 - 71
72
65 - 68 - 69 - 71
72
49 - 56
57 to 59
General-purpose probe
Graphical digital multimeter
O
OX 5022
OX 5042
OX 530
OX 6062B
OX 6202B
OX 7042
OX 7062
OX 71
OX 7102
OX 7104
OX 7202
OX 7202-BUS
OX 7204
OX 7204-BUS
OX 803B
Oxi 6204
On-site digital oscilloscope
On-site digital oscilloscope
Analogue oscilloscope
Laboratory digital oscilloscope
Laboratory digital oscilloscope
On-site digital oscilloscope
On-site digital oscilloscope
Oscilloscope analogique
On-site digital oscilloscope
On-site digital oscilloscope
On-site digital oscilloscope
Bus analyser oscilloscope
On-site digital oscilloscope
Bus analyser oscilloscope
Analogue oscilloscope
Laboratory digital oscilloscope
P
PAC11 Current clamp
PAC12
Insulated AC/DC current probe
PAC20 Current clamp
PAC22
Insulated AC/DC current probe
PROBIX Accessories for SCOPIX oscilloscopes
Pt100
Platinum probe PX 110Wattmeter
PX 120Wattmeter
28 - 29
112
28 - 29
112
73 - 74
105
39
39
AC current clamp
AC current probes
AC/DC current clamps
AC/DC current probes
Accessories for multimeters
Accessories for oscilloscopes
Acquisition software
Analogue ammeter
Analogue multimeter
Analogue oscilloscope
Analogue voltmeter
Arbitrary function generators
96 to 99
112
100
112
96 to 107
73 - 74
32 to 34
45
8, 13
56
45
85, 88, 89
C
Coaxial accessories
Component testers
Cos-phi meter
114
8, 9
40
D
DDS function generators
Didascope training oscilloscope
Differential voltage probes
Digital oscilloscope
85, 86, 87
48 to 53
110, 111
65 to 72
E
Earth (3P)
Earth loop
Electric field tester
41 to 43
41 to 43
8, 10, 11
F
Field bus oscilloscope
Field bus
Flexible current probes
Flexible probes for AC current
Fuses
72
72
113
113
116
G
112, 113
14, 15, 26, 27
H
High-voltage / high-frequency probe
108, 109
I
Insulation tester
Insulation
41 to 43
41 to 43
Metrology software
MTX family bag
Multi-function calibrator
Multi-function installation tester
Multi-function oscilloscope
Multimeter clamp
Multimeter for difficult environments
33
106
94, 95
44
65 to 72
35 to 38
15, 20, 21
N
Near-field probe
82
O
On-site digital multimeter
On-site oscilloscope
14 to 26
65 to 72
P
PROBIX system
Process current clamp
Programmable power supply
Pt 100
73, 74
101
90, 92
105
R
RCD testing
41 to 43
S
SCOPIX bag
SCOPIX equipped case
Screenless oscilloscope
Shunt
Software for oscilloscopes Spectrum analyser
115
115
49 to 55
93
76, 77
78 to 82
T
Testing and electrical safety
Training box
Training oscilloscope
Transport accessories
41 to 44
93
48 to 53
106, 107, 115
V
Variable power supplies
Voltage probes
Voltage tester
90, 91
108 to 111
8, 12
W
Wattmeter
39
K
K thermocouple
100, 104
L
Laboratory multimeter
Laboratory oscilloscope
Leads
Leakage current clamp
Lighting-arrester tester
15, 30, 31
57 to 64
102, 103
101
42
S
SCOPENET
SK
SX METRO
SX-ASYC2C/B
SX-DMM
Software for oscilloscopes
K-thermocouple sensors
Software for oscilloscopes
Software for multimeters
Software for multimeters
77
104
76
33
32
T
TCX 01
TX 01
SMD / Surface Mounted Device tester
LED voltage tester
8&9
8 & 12
V
VIRTUAL PRINTER
VX 0003
VX 0100
118
Software for oscilloscopes
LF electric field tester
LF electric field tester
76
8 – 10 - 11
8 – 10 – 11
Y
Y7N
AC current probe
Detailed product brochures can be downloaded free of charge from www.metrix.fr
112
www.metrix.fr
119
index by reference
index by reference
ReferencePage
ReferencePage
ReferencePage
ReferencePage
ReferencePage
ReferencePage
A
HX0073
HX0077
HX0082
HX0083
HX0091
HX0092
HX0093
HX0094
HX0095
HX0096
HX0102
HX0106
HX0107
HX0108
HX0112
HX0130
HX0190
HX0191
HX0206
HX0210
HX0220
HX2002
MX5060
MX57EX-CAL
MX9030-Z
P01120083
P01120301
P01120303
P01120304
P01120305
P01120308
P01120309
P01120401
P01120402
P01120402
P01120405
P01120409
P01120415
P01120416
P01120421
P01120421
P01120501
P01120502
P01120503
P01120504
P01120505
P01120506
P01120507
P01120508
P01120509
P01120560
P01120561
P01120562
P01120563
P01120564
P01120565
P01120570
P01120571
P01120572
P01196770
P01196770
P01197401
P01197402
P01197403
P01197404
P01295073A
P01295073A
P01295288Z
P01295289Z
P01295290Z
P01295293
P01295450Z
P01295451Z
P01295452Z
P01295453Z
P01295454Z
P01295455Z
P01295456Z
P01295457Z
P01295458Z
P01295459Z
P01295460Z
P01298004
P01298068
P01298069
P01298071
P01298072
P01330401
P01637301
P01651610Z
P01652401Z
P01652411Z
P03197521A
P03197522A
P03197523A
P03197524A
P03197525A
P03197526A
P03197527A
P03197528A
P03295509
P03652712
P03652713
P03652714
P03652715
P03652901
P03652902
P03652903
P03652904
P03652905
P03652906
P03652907
P03652908
P03652909
P03652910
P03652913
P03652914
P03652917
P03652918
P03652919
P03652920
P03652921
P03652922
P06239307
PA4119-50
PX0110
PX0120
AE0193
AE0216
AE0227
AE0228
AE0237
AG1066-Z
AX0501A
AX0502A
AX0503A
AX1360-P
106
106
106
106
106
102
91
91
91
92
C
CX1651
94
D
DOX2025
DOX2040
DOX2100
DOX3104
DOX3304
60
60
60
63
63
L
E
Soft case AE0190
106
88
88
86
86
86
86
86
H
HA030-1
HA050
HA050-1
HA2004-Z
HA2005
HX0003
HX0004
HX0005
HX0006
HX0007
HX0008
HX0009
HX0010
HX0011
HX0012
HX0013
HX0018
HX0021
HX0024
HX0027
HX0028
HX0029
HX0030B
HX0031
HX0032
HX0033
HX0034
HX0035B
HX0036
HX0038
HX0050
HX0051B
HX0052
HX0052B
HX0052C
HX0053
HX0055
HX0056-Z
HX0057
HX0059
HX0064
HX0071
HX0072
LX1600-PC
54
M
G
GX1025
GX1050
GX305
GX310
GX310-P
GX320
GX320-E
73
75
81
81
103
103
74
73
74
73
67
87
87
108
51
74
72
72
109
109
109
33
93
93
93
114
114
108
108
108
108
108
108
108
106
39
39
39
102
39
111
109
75
75
74
74
74
74
73
74
74
111
33
23
23
20
23
20
33
20
111
33
99
74
73
MC0159B
MC0160B
MTX1032-B
MTX1032-BRK
MTX1032-C
MTX1032-CRK
MTX1050-PC
MTX1052B-PC
MTX1052B-RK
MTX1052BW-PC
MTX1052CW-PC
MTX1054B-PC
MTX1054B-RK
MTX1054BW-PC
MTX1054CW-PC
MTX112U
MTX162UE
MTX162UEW
MTX202-Z
MTX203-Z
MTX2022W-P
MTX2024W-P
MTX3290
MTX3291
MTX3292
MTX3292-BT
MTX3293
MTX3293-BT
MX0001-T
MX0002B
MX0002BT
MX0024B-CL
MX0024B-CZ
MX0024-CG
MX0024-CL
MX0026-G
MX0026-T
MX0057CX
MX0350-Z
MX0355-Z
MX0407
MX0435D
MX0604
MX0650-Z
MX0655-Z
MX0670
MX0675
MX098
MX1
MX125
MX135
MX406B
MX5006
106
106
110
110
110
110
79
55
55
55
55
55
55
55
55
53
52
52
17
17
55
55
25
25
27
27
27
27
13
13
13
26
26
26
26
26
26
21
36
36
43
44
42
37
37
38
38
40
11
45
45
42
31
31
33
110
O
OX7204-BUS
OX0530
OX0530-S
OX0803B
OX0830BS
OX5022-C
OX5022-CK
OX5042-C
OX5042-CK
OX6062B-CFG
OX6062B-CSD
OX6062B-CSDO
OX6062B-MSD
OX6202B-CFG
OX6202B-CSD
OX6202B-CSDO
OXi6204
OX7202-BUS
OX7042-CSD
OX7042-MSD
OX7042P-CSDK
OX7062-CSD
OX71
OX7102-CSD
OX7104-CSD
OX7104-CSD
OX7104-CSDO
OX7104P-CSDK
OX7202-CSD
OX7204-BUS
OX7204-CSD
OX7204-CSDO
71
56
56
56
56
67
67
67
67
59
59
59
59
59
59
59
59
72
69
69
69
69
56
69
69
69
69
69
69
72
69
69
P
P01101846
P01101846
P01101847
P01101847
P01101892A
P01101892A
P01101914
P01101965
P01101966
P01101967
P01101968
P01102019
P01102021
P01102034
P01102053Z
P01102055Z
P01102082
P01102084
P01102084A
P01102086
P01102087
P01102101Z
P01102101Z
P01102106Z
P01102107Z
P01105101Z
P01105101Z
P01105102Z
P01105105Z
P01120040A
P01120043A
P01120047*
P01120057A
P01120067A
P01120068
P01120069
P01120071
P01120072
P01120073
P01120074A
P01120075
99
110
99
110
93
110
110
96
96
96
95
44
44
9
98
99
63
9
44
95
109
99
110
99
99
11
94
94
94
96
108
108
108
97
96
96
96
108
108
96
108
120
97
94
94
94
94
108
97
94
11
94
94
108
94
94
44
97
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
109
109
109
32
33
93
93
93
93
89
110
98
98
98
33
102
102
102
102
102
102
102
102
102
99
98
107
107
107
107
107
39
34
67
67
67
93
93
93
93
93
93
93
93
39
105
105
105
105
104
104
104
104
104
104
104
104
104
104
104
104
104
104
104
104
104
104
99
110
39
39
S
SX-ACQ.V2
SX-ASYC2C/B
SX-ASYC2HD
SX-DMM2
SX-DMMBT/B
SX-DMMK2
SX-PROG.1
28
33
33
33
33
33
33
T
TX0001-Z
TX001-Z
10,11
10
V
VX0003
VX0100
11
11
121
Detailed product brochures can be downloaded free of charge from www.metrix.fr
www.metrix.fr
CONTENTS
index by reference
The Group: History & Values…
Selection guide for on-site oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . 65
OX 5022 & OX 5042 Handscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
SCOPIX family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SCOPIX for industrial maintenance: OX 7042 & OX 7104 . . . . . . . . . 70
SCOPIX for electronics: OX 7062, OX 7102, OX 7104,
OX 7202 & OX 7204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Scopix Fieldbus: OX 7202BUS & OX 7204BUS . . . . . . . . . . . . . . . . . . . 72
PROBIX accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
OX software accessories: SX METRO & virtual printer . . . . . . . . . . . . 76
OX software accessories: SCOPE ADMIN & SCOPENET . . . . . . . . . . . 77
Innovations, Ergonomics & Awards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Illustrated Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Testers
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SMD Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LF electric field testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Voltage tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Multimeters
On-site multimeter selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
MX1 & MX2B analogue on-site multimeters . . . . . . . . . . . . . . . . . . . . . . 13
Digital on-site multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MTX 202 & MTX 203 family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
• MX Concept RMS family: MX 24, MX 24B & MX 26 . . . . . . . . . . . . . . 18
• ATEX MX 57Ex for difficult environments . . . . . . . . . . . . . . . . . . . . . 20
• ASYC IV family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• MTX 3290 & MTX 3291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
• MTX 3292 & MTX 3293 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
• Clamps for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MX 5006 & MX 5060 laboratory multimeters . . . . . . . . . . . . . . . . . . . 30
Spectrum analyser connected to PC: MTX 1050 . . . . . . . . . . . . . . . . . 80
EMC prequalification: HX 0082 & HX 0083 . . . . . . . . . . . . . . . . . . . . . . 82
Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Technological Breakthroughs and Patented
Discoveries
As a French brand known nationwide by generations of electricians and electronic engineers,
to the point of becoming the generic name for multimeters in France, Metrix® is Chauvin Arnoux’s
flagship brand in electronics for multimeters, oscilloscopes, power supplies and generators.
The Engineering Department and R&D teams are still based on the site at Annecy-le-Vieux,
but they can now take full advantage of the high-performance industrialization tools on the Group’s
production sites in Normandy.
Generator selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
LF generators: GX 305, GX 310 & GX 320 . . . . . . . . . . . . . . . . . . . . . . . 86
GX 1025 & GX 1050 generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Metrix: from the lampmeter, the electro-clamp
and oscilloscopes to “the Metrix”
Laboratory power supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
AX 501, AX 502 & AX 503 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
AX 1360-P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Software for multimeters
SX-DMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SX-ASYC2C/B, MX 57EX-CAL & HX 0059 . . . . . . . . . . . . . . . . . . . . . . . 33
Communication accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
In 1936, Georges Friédrichs founded a small
company named CARTEX. This company enjoyed
considerable growth during the years of economic
expansion following the Second World War.
Training equipment (shunts, etc.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
CX 1651 multi-function laboratory calibrator . . . . . . . . . . . . . . . . . . . . 94
Multimeter clamps
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
350-355 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
650-655 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
670-675 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Accessories
PX 110 & PX 120 wattmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
MX 98 cos-phimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Accessories for multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
AC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Flexible AC current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
AC/DC current clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Current clamps for specific requirements . . . . . . . . . . . . . . . . . . . . . . . 101
Generic cables and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
K-thermocouple and Pt100 probes and sensors . . . . . . . . . . . . . . . . . 104
Transport and protection accessories . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Electrical safety testers
Insulation testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
MX 406B & MX 604 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
MX 407 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MX 435D multi-function installation tester . . . . . . . . . . . . . . . . . . . . . . 44
Training equipment
Analogue voltmeter & ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
1950: launch of the MX 460…
Accessories for oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Voltage probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
MX 9030, MTX 1032B & MTX 1032C differential voltage probes . . . 110
Insulated current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Flexible current sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Coaxial accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Transport and protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Oscilloscopes
Introduction to analogue oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . 46
Introduction to digital oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Selection guide for analogue and [email protected] oscilloscopes . . . . . . . . 49
[email protected] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
MTX 162 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
MTX 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MTX 1052 & MTX 1054 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
OX 530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 803B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
OX 71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Index
By product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
By function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
By reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
…and the MX 400 electro-clamp
Selection guide for benchtop digital oscilloscopes
DOX 2000 & OX 6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
OX 6062B, OX 6202 & OXi 6204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
DOX 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
DOX 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Software for benchtop oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
USB
Power
Diode test
Frequency
Smart
persistence
oscilloscope
IEC 61010
electrical safety
Ethernet
Capacitance
Min, Max,
Avg and PEAK
Resistance
Fourier
transform
IEC 61010
electrical safety
Android
Current
Measurement with
current clamp
Reactive
power
Multimeter
2.5 or 50-kpoint
memory depth
Recording
Continuity
3 sockets
Apparent
power
MATH
functions
50-kpoint
memory depth
Temperature
Voltage
Decibel
Harmonics
2-Mpoint
memory depth
Protection rating
ASYC IV 100-kcount colour graphical
multimeter
Its main business was manufacturing portable
“lampmeters” for checking the valves used in the
radioelectricity sector, which was growing fast
at the time. With the rising demand for electrical
and electronic measurement equipment, CARTEX
quickly became a major player in this sector, with
products such as the lampmeter, testers and
frequency generators. In 1946, it changed its name
to “Compagnie Générale de Métrologie” (General
Metrology Company) and began marketing its
products under the Metrix brand.
Reference
P01120083
P01120301
P01120303
P01120304
P01120305
P01120308
P01120309
P01120401
P01120402
P01120402
P01120405
P01120409
P01120415
P01120416
P01120421
P01120421
P01120501
P01120502
P01120503
P01120504
P01120505
P01120506
P01120507
P01120508
P01120509
P01120560
P01120561
P01120562
P01120563
P01120564
P01120565
P01120570
P01120571
P01120572
P01196770
P01196770
P01197401
P01197402
P01197403
P01197404
P01295073A
P01295073A
Page
97
94
94
94
94
108
97
94
11
94
94
108
94
94
44
97
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
109
109
109
32
33
93
93
93
93
89
110
Reference
P01295288Z
P01295289Z
P01295290Z
P01295293
P01295450Z
P01295451Z
P01295452Z
P01295453Z
P01295454Z
P01295455Z
P01295456Z
P01295457Z
P01295458Z
P01295459Z
P01295460Z
P01298004
P01298068
P01298069
P01298071
P01298072
P01330401
P01637301
P01651610Z
P01652401Z
P01652411Z
P03197521A
P03197522A
P03197523A
P03197524A
P03197525A
P03197526A
P03197527A
P03197528A
P03295509
P03652712
P03652713
P03652714
P03652715
P03652901
P03652902
P03652903
P03652904
Page
98
98
98
33
102
102
102
102
102
102
102
102
102
99
98
107
107
107
107
107
39
34
67
67
67
93
93
93
93
93
93
93
93
39
105
105
105
105
104
104
104
104
Reference
P03652905
P03652906
P03652907
P03652908
P03652909
P03652910
P03652913
P03652914
P03652917
P03652918
P03652919
P03652920
P03652921
P03652922
P06239307
PA4119-50
PX0110
PX0120
Page
104
104
104
104
104
104
104
104
104
104
104
104
104
104
99
110
39
39
S
SX-ACQ.V2
SX-ASYC2C/B
SX-ASYC2HD
SX-DMM2
SX-DMMBT/B
SX-DMMK2
SX-PROG.1
28
33
33
33
33
33
33
T
TX0001-Z
TX001-Z
10,11
10
V
VX0003
VX0100
11
11
The launch of the “electro-clamp”, allowing users to
check voltages without disconnecting and measure
high currents with one hand, and the production
of oscilloscopes from 1948 onwards helped to
quickly expand the company’s offering. However,
the products that really made the brand’s reputation
were the MX 460, launched in 1950, and more
particularly, the MX 462 multimeter, which was so
successful that “Metrix®” became the generic name
for multimeters in France, enabling the company to
grow very fast.
121
vez l’ensemble de l’offre
d’automatismes pour répondre
es les exigences des secteurs
ie, énergie, ferroviaire…
FR
2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex - France
Tel.: +33 1 75 60 10 30
Fax: +33 1 46 66 62 54
[email protected] - www.enerdis.fr
LILLE
Tel.: 03 20 55 96 41 - Fax: 03 20 06 33 61
[email protected]
NANTES
Tel.: 02 40 84 01 16 - Fax: 02 40 75 35 55
[email protected]
LYON
Tel.: 04 72 65 77 60 - Fax: 04 78 03 15 39
[email protected]
PARIS
Tel.: 01 44 85 45 75 - Fax: 01 46 27 07 48
[email protected]
NANCY
Tel.: 03 83 92 19 21 - Fax: 03 83 90 32 11
[email protected]vin-arnoux.fr
TOULOUSE
Tel.: 05 62 74 50 30 - Fax: 05 61 71 45 06
[email protected]
For professionals like you: contractors,
technicians and engineers in the electrical sector
international
Measuring instruments
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
Tel.: +33 1 44 85 44 38 - Fax: +33 1 46 27 95 59
[email protected] - www.chauvin-arnoux.fr
n For electrical installation testing
n For maintenance of industrial
electrical and electronic systems
n For metrology: precision measurements
n For design work: research and
development
10 subsidiaries spread across the world
GERMANY
CHAUVIN ARNOUX GMBH
Ohmstraße 1
77694 KEHL / RHEIN
Tel.: +49 7851 99 26-0 - Fax: +49 7851 99 26-60
[email protected]
www.chauvin-arnoux.de
Catalogue Pyro Capteurs 2013.indd 1
05/02/2013 09:03:14
PYROCONTROLE
6 bis, av du Docteur Schweitzer
69881 MEYZIEU Cedex - France
Tel.: +33 4 72 14 15 40
Fax: +33 4 72 14 15 41
[email protected]
www.pyrocontrole.com
MÉTROLOGIE & CONTRÔLES RÉGLEMENTAIRES
MANUMESURE
248, av des Grésillons
92600 ASNIÈRES sur SEINE - France
Tel.: +33 1 75 61 01 90
Fax: +33 1 47 33 28 02
[email protected]
www.manumesure.fr
AUSTRIA
CHAUVIN ARNOUX GES.M.B.H
Slamastrasse 29/2/4
1230 WIEN
Tel.: +43 1 61 61 9 61 - Fax: +43 1 61 61 9 61-61
[email protected]
www.chauvin-arnoux.at
CHINA
SHANGHAI PU-JIANG ENERDIS
INSTRUMENTS CO. LTD
N° 381 Xiang De Road
3 Floor, Building 1
200081 SHANGHAI
Tel.: +86 21 65 21 51 96 - Fax: +86 21 65 21 61 07
[email protected]
SPAIN
CHAUVIN ARNOUX IBÉRICA SA
C/ Roger de Flor N°293
1a Planta
08025 BARCELONA
Tel.: +34 902 20 22 26 - Fax: +34 934 59 14 43
[email protected]
www.chauvin-arnoux.es
ITALY
AMRA SPA
Via Sant’Ambrogio, 23
20846 MACHERIO (MB)
Tel.: +39 039 245 75 45 - Fax: +39 039 481 561
[email protected]
www.chauvin-arnoux.it
Test & Measurement catalog 2016
International
Tél. : +33 1 75 60 10 30
Fax : +33 1 46 66 62 54
[email protected]
Catalogue général
MIDDLE EAST
CHAUVIN ARNOUX MIDDLE EAST
PO Box 60-154
1241 2020 JAL EL DIB
(Beyrouth) - LIBAN
Tel.: +961 1 890 425 - Fax: +961 1 890 424
[email protected]
www.chauvin-arnoux.com
UNITED KINGDOM
CHAUVIN ARNOUX LTD
Unit 1 Nelson Ct, Flagship Sq
Shaw Cross Business Pk, Dewsbury
West Yorkshire - WF12 7TH
Tel.: +44 1924 460 494 - Fax: +44 1924 455 328
[email protected]
www.chauvin-arnoux.com
SCANDINAVIA
CA MÄTSYS TEM AB
Sjöflygvägen 35
SE-183 62 TABY
Tel.: +46 8 50 52 68 00 - Fax: +46 8 50 52 68 10
[email protected]
www.camatsystem.com
From design through
to industrialization
n Measurement of electrical quantities
in total safety
Rugged, reliable, portable
instruments which are high-quality,
safe and easy to use
n Sales agencies and staff at your service
n Technical centres: calibration and repairs
n A multi-product website and mini-sites
dedicated to specific product ranges
SWITZERLAND
CHAUVIN ARNOUX AG
Moosacherstrasse 15
8804 AU / ZH
Tel.: +41 44 727 75 55 - Fax: +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
USA
CHAUVIN ARNOUX INC
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tel.: +1 (508) 698-2115 - Fax: +1 (508) 698-2118
[email protected]
www.aemc.com
Expertise
n Technical support, training,
mock-ups, etc.
Metrix is a brand of Chauvin Arnoux
A response based on instruments designed,
developed, manufactured and checked by professionals
in the electrical sector
906 131 117
France
Tél. : 01 75 60 10 30
Fax : 01 46 66 62 54
[email protected]
Catalogue général 2015
ENERDIS
16, rue Georges Besse - Silic 44
92182 ANTONY Cedex
www.enerdis.fr
906 130 080 - Ed. 9 - 12/2014 - Document non contractuel - Caractéristiques à se faire confirmer à la commande - Photos et shémas non contractuels.
USA
Chauvin Arnoux Inc
d.b.a AEMC Instruments
200 Foxborough Blvd.
Foxborough - MA 02035
Tél. : +1 (508) 698-2115
Fax : +1 (508) 698-2118
[email protected]
www.aemc.com
UN CONTACT
CENTRALISÉ
Multimeters, clamps,
testers and laboratory instruments
A STRUCTURE BASED ON LOCAL AGENCIES IN FRANCE
SUISSE
Chauvin Arnoux AG
Einsiedlerstrasse 535
8810 HORGEN
Tél. : +41 44 727 75 55
Fax : +41 44 727 75 56
[email protected]
www.chauvin-arnoux.ch
190, rue Championnet - 75876 PARIS Cedex 18 - FRANCE
[email protected] - www.metrix.fr
GB
GB
GB
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project