Honeywell | W8600A | User's Manual | Honeywell W8600A User's Manual

W8600A AIRWATCH™ Indicator
INSTALLATION INSTRUCTIONS
APPLICATION
The W8600A is available for use with Honeywell media
or electronic air cleaners.
AM
System
Heat
Tue
Wake
DST
Room
Fan
TM
Auto
Batt ery
Air Clea
UV Air ner
Hum Trea tme nt
Honeywell.c idifi er
om/yourhom
e
The W8600A function indicator panel has four liquid
crystal display (LCD) arrowheads that point to Battery, Air
Cleaner, UV Air Treatment, and Humidifier. (See Fig. 1.)
A blinking arrowhead indicates service is needed.
LCD
M14697
TM
Fig. 2. W8600A mounting location.
Battery
Air Cleaner
UV Air Treatment
Humidifier
Honeywell.com/yourhome
Mounting
FUNCTION
INDICATOR
PANEL
These mounting instructions assume that the W8600A is
mounted next to a T8600 Thermostat. When installing at
another location, modify the procedure to fit the
installation:
1.
2.
3.
4.
5.
6.
Remove the W8600A from the base.
Mark the holes for the mounting screws (provided)
using the base as a template. See Fig. 3.
Drill the holes.
Position the base over the holes and install the
screws.
Tighten the screws until the base is mounted firmly
on the wall.
Replace the W8600A onto the base.
RESET BUTTON
M14696
THERMOSTAT
WALLPLATE
W6800A BASE
Fig. 1. W8600A AIRWATCH™ Indicator features.
INSTALLATION
WIRING HOLE
Location
MOUNTING HOLES (2)
The W8600A is designed to blend with the latest T8600
family of Honeywell Chronotherm® IV Thermostats. The
W8600A can also be mounted at any other convenient
location in the living area of the home. See Fig. 2.
® U.S. Registered Trademark
Copyright © 2000 Honeywell •
• All Rights Reserved
M14695
Fig. 3. Using base as mounting template.
69- 1448
W8600A AIRWATCH™ INDICATOR
SERVICE
Set DIP Switches
1.
Set the DIP switches according to equipment
installed in the home:
a. Use default position set at the factory when all
devices (air cleaner, UV air treatment system,
humidifier) are installed in the home.
b. Move DIP switch to left (off position) when a
device is not installed in the home.
NOTE: The UV air treatment system and the
humidifier settings are for one year. The
air cleaner settings are selectable according to homeowner activities and needs.
2.
Determine the air cleaner filter run time you desire
and set the DIP switches accordingly:
a. If air cleaner filter is used, select desired filter
time of 3, 6, 9 or 12 months. Follow the settings
on the back of the W8600A to set the DIP
switches for the desired number of months.
b. If air cleaner filter is not used, move the filter
time DIP switches 4 and 5 to the left (off).
c. Use factory default settings to change the
media filter or wash the electronic filter every
three months.
The unit beeps every fifteen minutes to indicate an LCD
is flashing. This means that service or a replacement part
is required.
1.
2.
3.
4.
Replace or service the part corresponding with the
LCD flashing.
Replace the batteries within 30 seconds of removal
to maintain the correct indication time.
Within 30 seconds after replacing the batteries, if
the LCD is blank, remove and install new batteries.
Press and hold the black button on the bottom of
the device to reset the timer after servicing or
replacing parts.
TROUBLESHOOTING
LCD
2.
3.
4.
5.
Remove the back cover by pressing in on the tab
on the bottom edge (top is hinged).
Install two AAA alkaline batteries (provided), in the
harness on the back of the unit.
Observe that the W8600A performs a self-test,
beeping and flashing the LCD display individually
for each device (air cleaner, UV air treatment system, humidifier) installed in the home.
Press and hold the black reset button on the bottom of the device for five seconds or until the display stops flashing to start the timers.
Observe Battery LCD:
a. On solidly means unit is correctly powered.
b. Flashing indicates battery requires replacing.
Reset by...
Battery
Batteries need
changing.
Changing batteries
within 30 seconds of
removing old batteries
to maintain correct
indication time.
Air Cleaner
Media filter needs
replacing or
electronic filter
needs washing.
Pressing and holding
reset button for 10
seconds or until arrow
is no longer displayed.
UV Air
Treatment
UV lamps need
Pressing and holding
replacing in UV air reset button for 10
treatment system. seconds or until arrow
is no longer displayed.
Humidifier
Humidifier pad
needs replacing.
Install Batteries
1.
If arrow is
flashing or unit
is beeping...
Pressing and holding
reset button for 10
seconds or until arrow
is no longer displayed.
Home and Building Control Home and Building Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
69-1448 G.H. 9-00
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
www.honeywell.com/your home/