Hewlett-Packard 8447 D, E, F Wideband Amplifier Operation and Service Manual
HP 8447D is a general purpose, wideband amplifier that provides 26 dB of gain. It consists of a power supply and one thin film, hybrid, integrated circuit amplifier. The thin film amplifier is hermetically sealed and features low noise, low distortion, flat frequency response, and long term stability and reliability.
PDF
Download
Document
Advertisement
Advertisement
OPERATION AND SERVICE MANUAL 64470 8447E 8447F AMPLIFIER 0.1—1300 MHz HEWLETT PACKARD Гу CERTIFICATION Hewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-Packard further certifies that its calibration measurements are traceable to the United States National Bureau of Standards, to the extent allowed by the Bureau's calibration facility, and to the calibration facilities of other International Standards Organization members. WARRANTY This Hewlett-Packard instrument product is warranted against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, Hewlett-Packard Com- pany will, at its option, either repair or replace products which prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by HP. Buyer shall prepay shipping charges to HP and HP shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes for products returned to HP from another country. HP warrants that its software and firmware designated by HP for use with an instrument will execute its programming instructions when properly installed on that instrument. HP does not warrant that the operation of the instrument, or software, or firmware will be uninterrupted or error free. LIMITATION OF WARRANTY The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or main- tenance. NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. HP SPECIFICALLY DISCLAIMS THE IM- PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EXCLUSIVE REMEDIES THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES. HP SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSE- QUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY. ASSISTANCE Product maintenance agreements and other customer assistance agreements are available for Hewlett- Packard products. For any assistance, contact your nearest Hewlett-Packard Sales and Service Office. Addresses are provided at the back of this manual. UA Packano OPERATION AND SERVICE MANUAL 8447D 8447E 8447F AMPLIFIER 0.1— 1300 MHz SERIAL NUMBERS This manual applies directly to instruments with the following serial number prefixes: 8447D: 1937A 8447E: 1937A 8447F: 1937A With changes described in MANUAL BACK- DATING CHANGES, this manual also applies to instruments with serial numbers prefixed 0933A, 1145A, 1529A, 1616A, 1644A, 1726A. For additional important information about serial numbers, see INSTRUMENTS COVERED BY MANUAL. Copyright © 1973, 1980, HEWLETT-PACKARD COMPANY 1400 FOUNTAIN GROVE PARKWAY, SANTA ROSA, CALIFORNIA, 95404, U.S.A. MANUAL PART NUMBER 08447-90033 Printed: SEPTEMBER 1980 SAFETY CONSIDERATIONS GENERAL This product and related documentation must be reviewed for familiarization with safety markings and instructions before operation. This product has been designed and tested in accordance with inter- national standards. SAFETY SYMBOLS A Instruction manual symbol: the product will be marked with this symbol when it is necessary for the user to refer to the instruc- tion manual (refer to Table of Contents). 7 Indicates hazardous voltages. + Indicates earth (ground) terminal. The WARNING sign denotes a | WARNING | hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met. eet The CAUTION sign denotes a $ CAUTION 3 hazard. It calls attention to an operating procedure, practice, or the like, which, if not correctly performed or adhered to, could result in damage to or destruc- tion of part or all of the product. Do not proceed beyond a CAU- TION sign until the indicated conditions are fully understood and met. SAFETY EARTH GROUND This is a Safety Class I product (provided with a protective earthing terminal). An uninterruptible safety earth ground must be provided from the main power source to the product input wiring ter- minals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, the product must be made inoperative and be secured against any unintended operation. BEFORE APPLYING POWER Verify that the product is configured to match the available main power source per the input power configuration instructions provided in this manual. If this product is to be energized via an autotrans- former make sure the common terminal is con- nected to the neutral (grounded side of mains supply). SERVICING | WARNING | Any servicing, adjustment, maintenance, or repair of this product must be per- formed only by qualified personnel. Adjustments described in this manual may be performed with power supplied to the product while protective covers are removed. Energy available at many points may, if contacted, result in per- sonal injury. Capacitors inside this product may still be charged even when disconnected from its power source. To avoid a fire hazard, only fuses with the required current rating and of the specified type (normal blow, time delay, etc.) are to be used for replacement. Model 8447D/E/F 1. GENERAL INFORMATION 2. The HP Models 8447D, 8447E and 8447F are general purpose, wideband amplifiers. Each instru- ment consists of a power supply and one or two thin film, hybrid, integrated circuit amplifiers. The thin film amplifiers are hermetically sealed and feature low noise, low distortion, flat frequency response, and long term stability and reliability. 3. The HP Model 8447D Amplifier is a pre- amplifier that provides 26 dB of gain to signals from 100 kHz to 1.3 GHz. It can be used to increase the sensitivity of any lab, shop or field device operating within its frequency range. Page 1 4. The HP Model 8447E Amplifier is a power amplifier that provides 22 dB of gain to signals from 100 kHz to 1.3 GHz. It can be used to increase the output power of signal generators, sweepers and similar devices operating within its frequency range. 5. The HP Model 8447F Amplifier contains a preamplifier and a power amplifier — the same thin film amplifiers used in the HP 8447D and HP 8447E. The input and output ports of both amplifiers are available on the front panel; they can be used separately or cascaded to provide 48 dB of gain. Table 1. Specifications 8447D 8447E 8447F PRE AMP POWER AMP PRE AMP POWER AMP Frequency Range 0.1 to 1300 MHz |0.1 to 1300 MHz |0.1 to 1300 MHz | 0.1 to 1300 MHz Typical 3 dB Bandwidth .05 to 1400 MHz |.05 to 1400 MHz |.05 to 1400 MHz |.05 to 1400 MHz Mean Gain (20° — 30°C) | 26 dB Minimum |22 dB +1.5 dB 26 dB Minimum |22 dB +1.5 dB Gain Flatness Across +1.5 dB +1.5 dB +1.5 dB + 1.5 dB Full Frequency Range Noise Figure < 8.5 dB <11 dB <8.5dB <11 dB (Typical) (Typical) output Power Cor 1 dB >+7 dBm >+15 dBm >+7 dBm >+15 dBm ain Compression (Typical) (Typical) Harmonic Distortion oon и or t —30 dB for 0 dB or t —30 dB for m outpu m outpu (Турка! +10 dBm output (Typical) +10 dBm output Typical Output for <—60 dB — 30 dBm —20 dBm —30 dBm —20 dBm Harmonic Distortion <2.0 INPUT < 2.0 INPUT VSWR, 1 to 1300 MHz <2 9 OUTPUT < 2.2 < 2.2 OUTPUT <2.2 Impedance 500 50 9 50 Q 50Q Reverse Isolation >40 dB >40 dB >40 dB >40 dB Maximum DC Voltage Input +10 V +10 V +10 V +10 V Typical Risetime 400 psec 420 psec 400 psec 420 psec Typical Group Delay 1.1 nsec* 1.5 nsec** 1.1 nsec* 1.5 nsec** Page 2 Model 8447D/E/F Table 1. Specifications (Cont’d) 8447D 8447E 8447 F PRE AMP POWER AMP PRE AMP POWER AMP . Le. 3 lbs., 8 oz. 3 lbs., 8 oz. Net Weight; (1,59 kg.) (1,59 kg.) 3 lbs., 14 oz. (1,75 kg.) Option 001 ne ee a J lbs., 10 oz. J lbs., 10 oz. Option 010 (1,64 kg.) (1,64 kg.) 4 1bs., 1 oz. (1,84 kg.) Option 011 “81 к y E. Dimensions 8-1/2 inches (216 mm) by 5-1/8 inches (130 mm) © by 3-3/8 inches (85, 8 mm) Power Requirements 115 or 230 Vac +10%, 48 to 440 Hz, 15 Watts, 27 VA max. * Variation over any 50 MHz band from 0.1 — 1300 MHz is typically < 0.15 nsec. **Variation over any 50 MHz band from 0.1 — 1300 MHz is typically < 0.25 nsec. 6. OPTIONS 7. The HP Model 8447D is a single preamplifier with BNC connectors. However, to provide flexi- bility, three options are offered: a. Option 001 — dual preamplifier, BNC connectors. b. Option 010 — single preamplifier, Type N connectors. с. Option 011 — dual preamplifier, Type N connectors. 8. The HP Model 8447E is a power amplifier with BNC connectors; one option is offered: Option 010 — Type N connectors. 9. The HP Model 8447F is a preamplifier and a power amplifier with BNC connectors; one option is offered: Option 010 — Type N connectors. NOTE All dual amplifier options with Type N connectors are furnished with a rigid coaxial cable (W6) that can be used to cascade the amplifiers with minimum loss. 10. INSTRUMENTS COVERED BY MANUAL 11. This manual fully documents the HP 8447D, HP 8447E and the HP 8447F. Any references in the manual apply to all three amplifiers unless otherwise noted. 12. Each amplifier has a ten digit serial number on the serial plate on the rear panel; the first five digits of the serial number are a prefix. The contents of this manual apply directly to instru- ments with the same serial number prefix as listed after SERIAL NUMBERS on the inside title page. 13. Revisions required to adapt the manual to other serial number prefixes are contained in a yellow “Manual Changes” insert supplied with the manual. For information about serial number prefixes not listed on the title page or in the insert, contact your nearest Hewlett-Packard office. 14. INITIAL INSPECTION 15. Mechanical Check 16. If damage to the shipping carton is evident, ask the carrier’s agent to be present when the instrument is unpacked. Inspect the instrument for mechanical damage. Also check the cushioning material for signs of severe stress. Model 8447D/E/F 17. Performance Check 18. The electrical performance of an amplifier should be verified upon receipt. Performance checks suitable for incoming inspection are given in paragraphs 55 through 58. 19. Claims for Damage 20. If the instrument is mechanically damaged in transit, notify the carrier and the nearest Hewlett- Packard field office immediately. A list of field offices is contained in the back of this manual. Retain the shipping carton and padding material for the carrier’s inspection. The field office will arrange for replacement or repair of your instru- ment without delay for claim settlements against the carrier. Before shipment, this instrument was inspected and found free of mechanical and elec- trical defects. If there is any deficiency, or if electrical performance is not within specifications, notify your nearest Hewlett-Packard sales and service office. 21. PREPARATION FOR USE 22. Power Requirements 23. The amplifier operates from 115 or 230 volts ac line voltage at any line frequency between 48 and 440 Hz. A slide switch on the rear panel is set to the correct position for the line voltage available. 24. Power Cable 25. To protect operating personnel, the National Electrical Manufacturer’s Association (NEMA) rec- ommends that the instrument panel and cabinet be grounded. All Hewlett-Packard instruments are equipped with a three-conductor power cable which, when plugged into the appropriate recep- tacle, grounds the instrument. The offset pin on the power cable’s three-prong connector is the ground wire. The power cord and power input connector meet the specifications established by the International Electrotechnical Commission (IEC). 26. Mating Connectors 27. Mating connectors used with the amplifier should be 50-ohm type BNC male. If the amplifier has the optional Type N connectors, use Type N male connectors that are compatible with US MIL-C-39012. Page 3 28. Operating Environment 29. The operating range of the amplifier is from O%C to +559C. The amplifier can be stored in a temperature range of —40°C to +75°C. 30. Bench Mounting 31. The amplifier is equipped with plastic feet and tilt stand in place, ready for use as a bench instrument. 32. Rack Mounting 33. The amplifier may be rack mounted by using an adapter frame. The adapter frame is a rack frame that accepts several combinations of sub- modular units. For additional information, address inquiries to your nearest Hewlett-Packard sales and service office. 34. STORAGE AND SHIPMENT 35. Packaging 36. The following paragraphs contain a general guide to repackaging of the instrument for ship- ment. Refer to paragraph 38 if the original container is to be used; refer to paragraph 40 if it is not. 37. If the instrument is to be shipped to Hewlett- Packard for service or repairs, attach a tag to the instrument identifying the owner and indicating the service or repair required; include the model number and full serial number of the instrument. 38. Original Packaging 39. If original container is to be used, proceed as follows: a. Place instrument in original container. If it is not available, a suitable container can be pur- chased from your nearest Hewlett-Packard sales and service office. b. Be sure the container is well sealed with strong tape or metal band. Page 4 Model 8447D/E/F = = = < Q 22 +25% 20 0.1 0.5 1.0 100 400 600 80011000 1200 1400 FREQUENCY (MHz) Gain vs. Frequency vs. Temperature + 40 - +40 - 7 — +30 + — +30- E E o +20 - S +201 œ +10- œ +101 5 0 3 04 a a = -10- = -10- 2 20 = -20- 1300 MHz © © _30- -30- SF, 1280 MHz -40- -40+ © -40 -30 -20-10 0 +10 +20 +30 -40-30 -20 -10 0 +10 +20 +30 INPUT POWER (dBm) INPUT POWER (dBm) Intermodulation Intercept Points bt ns SN oo > OUTPUT POWER (dBm) < NOISE FIGURE (dB) N 100 700 1000 1300 100 400 700 1000 1300 FREQUENCY (MHz) FREQUENCY (MHz) Output Power (1 dB Compression) vs. Frequency Noise Figure vs. Frequency Figure 1. Typical Preamplifier Performance Curves Model 8447D/E/F Page 5 GAIN (dB) 24 18 16 A AN" 1400 +250C 0.1 05 1.0 100 400 600 800 1000 1200 FREQUENCY (MHz) Gain vs. Frequency vs. Temperature +40 7 +40 - y +30 - +30- E +20 - E +20- x +10 + S +10- = 0 я = 0 = & -10- & -10- 5 — a -20 - a -20- > 5 -30- 3 -30- ; 1300 MHz -40- -40- F, 1280 MHz -40 -30 -20 -10 0 +10 +20 +30 -40 -30 -20 -10 0 +10 +20+30 INPUT POWER (dBm) INPUT POWER (dBm) Intermodulation Intercept Points OUTPUT POWER (dBm) 100 400 700 1000 1300 FREQUENCY (MHZ) Output Power (1 dB Compression) vs. Frequency Figure 2. Typical Power Amplifier Performance Curves Page 6 Model 8447D/E/F Table 2. Recommended Test Equipment and Accessories I . веет: Suggested nstrument Type Minimum Specifications Model Use* Generator/Sweeper Frequency Range: 0.1 to 110 MHz HP 8601A P,T Flatness: +0.25 dB over full range Output Level: +10 dBm minimum Frequency Accuracy: 1% +100 KHz Compatible with Network Analyzer Sweep Oscillator Frequency Range: 0.1 to 1.3 GHz HP 8620A/8621A P,T Flatness: 0.7 dB over full range Output Level: +10 dBm minimum Frequency Accuracy: +20 MHz Compatible with Network Analyzer Network Analyzer System (with a swept source) capable of HP 8407A P (0.1—110 MHz) measuring amplitude of reflected signals (return loss). Network Analyzer HP 8410 A (0.11—1.3 GHz) Frequency Range: 0.1 to 1300 MHz Resolution: 0.25 dB Phase-Magnitude Accuracy: +6% HP 8412A Display Harmonic Fre- HP 8411A quency Converter S-Parameter HP 8745A Test Set Universal HP 11604A Extension Transmission Kit HP 11651A Accessory Kit HP 11570A Spectrum Frequency Range: 10—1300 MHz HP 8555A P Analyzer Dynamic Range: 60 dB minimum RF Section Scan Width: 800 MHz minimum Spurious Responses: <—60 dB Spectrum Absolute amplitude calibration. HP 8552A Analyzer Variable persistance display. IF Section Display HP 141T Section Noise Figure Frequency Range: 0.1—1300 MHz HP 342A P Meter Noise Figure Range: 0—15 dB + VHF Noise Source | Accuracy: 10.5 dB HP 343A UHF Noise Source Excess Noise Ratio: 6.3 +0.5 dB HP 349A Model 8447D/E/F Page 7 Table 2. Recommended Test Equipment and Accessories (Cont’d) Instrument Type Minimum Specifications Suggested Use* Model RMS Voltmeter Voltage Range: 1 mV to 1 V (full range) HP 3400A PA, Frequency Range: 10 Hz to 10 MHz T Meter Accuracy: *5% Power Meter Power Range: —20 dBm to +10 dBm HP 432A/478A P Frequency Range: 10—1300 MHz Meter Accuracy: +1% Amplifier Gain: 24 dB HP 8447D P Noise: <8 dB Frequency Range: 0.1 — 1300 MHz Digital Voltmeter Voltage Range: 0 — 60 V HP 3440A/3444 A AT Accuracy: +.05% + 1 digit Resistance Range: 0 to 10 megohm Accuracy: + 0.3% +1 digit Double Balanced Frequency Range: 200 — 1300 MHz Sage Laboratories P Mixers 2500 Series Low Pass Filter Cutoff Frequency: 400 MHz Cir-Q-Tel P Attenuation: >60 dBat 800 and 1200 MHz FLT/2 Series Attenuator 10 dB, 0.1 — 1300 MHz HP 84914 Р Option 10 Attenuator 20 dB, 0.1 — 1300 MHz HF 8491 À Р Option 20 Termination 50 ohm (BNC) HP 11593A P Termination 50 ohm (Type N) HP 908A P Adapter Type N Female to BNC Male UG-349A/U P Adapter (2) BNC Female to Type N Male UG-201A/U P Tee BNC UG-274B/U P Cable Assembly Type N Connectors HP 11500A P Cable Assembly (5) | BNC Connectors HP 10503A P Cable Assembly BNC with test clips attached HP 10501 A AT Adapter BNC Female to Binding Post HP 10111A P,A,T Adapter BNC Male to BNC Male UG-491A/U P *Use: P = Performance Test; A = Adjustments; T = Troubleshooting Page 8 40. Other Packing Material 41. If original container is not used, proceed as follows: a. Wrap instrument in heavy paper or plastic before placing in inner container. b. Place packing material around all sides of the instrument and protect panel face with card- board strips. c. Place instrument in a heavy carton or wooden box and seal with strong tape or metal band. A double-wall carton made of 200 pound test material is adequate. d. Mark shipping container; Delicate Instru- ment. Fragile, etc. 42. OPERATING INSTRUCTIONS 43. Connect the line power cable to the three- prong rear panel socket and proceed as follows: a. Select the line power to be used (115 or 230 volts) with the rear panel SELECTOR switch. b. Connect the line power cable to line power. с. Push LINE switch ON. охото} Do not apply power levels to the ampli- fier that are higher than the following: 8447D: 0 dBm 8447E: +10 dBm 8447F PREAMP: 0dBm 8447F POWER AMP: +10 dBm d. Attach INPUT and OUTPUT cables { CAUTION } Power out of the 8447E and power out of the 8447F POWER AMP can exceed 100 mW. This may be enough power to damage sensitive circuits connected to OUTPUT. 44. OPERATOR MAINTENANCE 45. Operator maintenance is limited to replace- ment of the front panel LINE switch light, the Al Power Supply fuse, and the rear panel fuse. Model 8447D/E/F 46. Fuses 47. To replace the rear panel fuse (F1), remove the rear panel fuse knob and replace the fuse (see rear panel for value of F1). 48. To replace the Al Power Supply (A1F1) fuse, turn the instrument on its top. Lift tilt stand and remove the bottom cover. Replace the fuse on the Al Power Supply board (see parts list for value of A1F1). 49. Lamp Replacement 50. To replace the front panel line switch lamp (DS1), proceed as follows: a. Disconnect cord from rear panel receptacle. b. Pull the white cover portion of this switch from the instrument and then remove the lamp from inside the cover. c. Replace old lamp with a new lamp (see parts list for part number of DS1). d. Place white cover into switch receptacle. e. Align tab on white cover with socket and push in. 51. PERFORMANCE TESTS AND ADJUST— MENT PROCEDURE 52. Test equipment and accessories required to perform maintenance are listed in Table 2. Equip- ment other than recommended models can be used provided the minimum specifications are satisfied. 53. The performance tests assume the use of a standard amplifier with BNC connectors. If an amplifier with Type N connectors is to be tested, suitable adapters will have to be added to the equipment lists. 54. One series of performance tests and one ad- justment procedure covers all three amplifiers. Where required, test steps list equipment settings, etc., for each amplifier. If a test step lists only one setting or specification, it is valid for all three amplifiers. Disregard references to any amplifier not being tested. Model 8447D/E/F Page 9 PERFORMANCE TESTS 55. Gain Flatness, Mean Gain, and Gain Compression Specifications 8447D 8447E 8447 F PREAMP POWER AMP PRE AMP POWER AMP Gain Flatness Across Full Frequency Range +1.5 dB +1.5 dB +1.5dB +1.5 dB Mean Gain (20°C — 30°C 26 dB Minimum | 22 dB +1.5 dB 26 dB Minimum | 22 dB +1.5 dB Output Power for 1dB +15 dBm +15 dBm Gain Compression Description: Amplifier gain is measured at the maximum and minimum points of its frequency response (see Figures 1 and 2). The difference between highest measured gain and lowest measured gain should be less than 3 dB (gain flatness). Half of the sum of highest gain and lowest gain is measured mean gain and should be within 1.5 dB of specified gain. Compression is checked by measuring gain at the specified 1 dB compression point and comparing it to gain measured below compression. Equipment: Generator/Sweeper . 2. HP 8601 A Sweep Oscillator . HP 8620A/8621 A RMS Voltmeter HP 3400A Power Meter . HP 432A/478A BNC Cable Assembly 2). . HP 10503A BNC Tee . ‘ UG-274B/U 50 ohm Termination HP 11593A Adapter UG-349A/U Adapter UG-201 A/U Adapter HP 1250-0080 20 dB Attenuator . HP 8491 B-20 10 dB Attenuator . HP 8491B-10 SWEEP OSCILLATOR AMPLIFIER POWER METER : o UNDER TEST eg ggo|- e = о5= = +99 9-о9 - 2 RF OUT | pouT 10 d8 ATTENUATOR 20 dB ATTENUATOR 8 | ADAPTER | (STEP 2) | | (STEP 2) (STEP 1) | | MOUNT y | | — — — — — — бо —— ADAPTER ] BNC CABLE ASSEMBLY (STEP 1) ADAPTER MOUNT 10 dB ATTENUATOR (STEP 11) Figure 3. Gain Flatness, Mean Gain, and Gain Compression Test Setup: 10 MHz to 1.3 GHz Page 10 Model 8447D/E/F PERFORMANCE TESTS 55. Gain Flatness, Mean Gain, and Gain Compression (Cont.) Procedure: 1. To measure gain flatness and mean gain, connect the equipment as shown in Figure 3. Set the sweep oscillator for a 1.3 GHz, leveled, CW signal; set the signal level for —10 dBm out of the 10 dB attenuator (read on the power meter). 2. Disconnect the power meter from the sweep oscillator and 10 dB attenuator. Connect the sweep oscillator, through the 10 dB and 20 dB attenuators, to amplifier INPUT; connect the power meter to amplifier OUTPUT. Note the power meter reading. Use this reading to calculate amplifier gain. EXAMPLE: —7 dBm (read in step 2) minus —10 dBm (set in step 1) plus 20 dB (read from attenuator) = 23 dB (gain) Gain at 1300 MHz: dB NOTE Use attenuation printed on 20 dB attenuator; this may vary slightly, depending upon frequency. 3. Tune the sweep oscillator for a maximum indication on the power meter at 1150 +100 MHz. Disconnect the oscillator and the power meter from the amplifier. Connect the power meter, through the 10 dB attenuator, to the oscillator. Set the oscillator signal level for —10 dBm out of the attenuator. 4. Disconnect the power meter from the sweep oscillator and 10 dB attenuator. Connect the oscil- lator, through the 10 dB and 20 dB attenuators, to amplifier INPUT; connect the power meter to amplifier OUTPUT, Calculate and record amplifier gain (as performed in step 2). Gain at 1150 MHz: dB 5. Measure, calculate and record amplifier gain at the following frequencies; use the procedures outline in steps 3 and 4. Frequency Gain 800 +200 MHz (tune for minimum): dB 350 +100 MHz (tune for maximum): dB 6. Disconnect the sweep oscillator and the power meter from the amplifier. Connect the equipment as shown in Figure 4. Set the generator/sweeper for a 10 MHz, CW signal; set the signal level for —40 dB (read on the voltmeter). 7. Disconnect the voltmeter from the generator/sweeper. Connect the generator/sweeper to amplifier INPUT; connect the voltmeter, with the 50 ohm termination, to amplifier OUTPUT. Note the volt- meter reading. Use this reading to calculate amplifier gain. EXAMPLE: —18.5 dB (read in step 7) minus —40 dB (set in step 6) = 21.5 dB (gain) Gain at 10 MHz: dB Model 8447D/E/F Page 11 PERFORMANCE TESTS 55. Gain Flatness, Mean Gain, and Gain Compression (Cont.) GENERATOR! Р RMS SWEEPER AMPLIFIER VOLTMETER UNDER TEST = (el © In ° ~ Of = aX 8 | | STEP 7) | (STEPO | — — EL ZZ ОНИ N BNC CABLE ASSY > | ADAPTER |) 500 TERMINATION 7 ) BNC CABLE ASSY BNC TEE Figure 4. Flatness and Mean Gain Test Setup: 100 kHz to 10 MHz 8. Measure, calculate and record amplifier gain at the following frequencies; use the procedures outlined above. Frequency Gain 250 +100 kHz (tune for maximum): dB 100 kHz: dB 9. Select the highest and lowest gains from steps 2, 4, 5, 7, and 8. Subtract the lowest gain from the highest gain; the result is gain flatness and should be less than 3 dB. EXAMPLE: 23 dB (highest gain) minus 21.5 dB (lowest gain) = 1.5 dB (gain flatness) Gain Flatness: 3 dB 10. Add the highest and lowest gains together and divide by 2; the result is measured mean gain. EXAMPLE: 23 dB (highest gain) plus 21.5 dB (lowest gain) _ 5 £a 22.25 dB (mean gain) Min. Actual Max. Mean Gain, 8447D: 26 dB 8447E: 20.5 dB 23.5 dB 8447F PRE AMP: 26 dB 8447 F POWER AMP: 20.5 dB 23.5 dB NOTE Gain rolls off rapidly above 1300 MHz and below 0.1 MHz. If lowest gain was measured at either of these points, use a frequency counter to monitor the signal and repeat steps 1 through 10. Page 12 Model 8447D/E/F PERFORMANCE TESTS 55. Gain Flatness, Mean Gain, and Gain Compression (Cont.) 11. To check compression, connect the power meter mount, through the 10 dB attenuator, to am- plifier OUTPUT (as shown in Figure 3). Connect the sweep oscillator, through the 20 dB attenuator, to amplifier INPUT. Set the sweep oscillator for a leveled, 660 MHz, CW signal and set the signal level (read on the power meter) as follows: 844 7E: +5 dBm (+15 dBm ampl. output) 8447F POWER AMP: +5 dBm (+15 dBm ampl. output) 12. Without changing any of the sweep oscillator’s settings, move the 10 dB attenuator from am- plifier OUTPUT to amplifier INPUT; the power meter should now be connected directly to amplifier OUTPUT and the sweep oscillator should be connected through the 20 dB attenuator and the 10 dB attenuator to amplifier INPUT. 13. The power meter should read as follows: 8447E 8447F POWER AMP less than +6 dBm: less than +6 dBm: +6 dBm +6 dBm 14. Repeat steps 11 through 13 at various frequencies between 0.1 and 1300 MHz. 56. VSWR Specification (1 to 1300 MHz): 8447D 8447E 8447F PRE AMP POWER AMP PRE AMP POWER AMP < 2.0 INPUT <2.2 < 2.0 INPUT < 2.2 < 2.2 OUTPUT < 2.2 OUTPUT Description: A network analyzer is swept, in steps, from 1 to 1300 MHZz. At each step the analyzer's display is referenced to 0 dB return loss by shorting its output; the short is then removed and the amplifier's return loss is measured at INPUT and OUTPUT. Equipment: Sweep Oscillator . . HP 8620A/8621 A Generator/Sweeper . . e... HP 8601A Network Analyzer (0.1 to 110 MHz) HP 8407A Network Analyzer (0.11 to 1.3 GHz) HP 8410A Model 8447D/E/F Page 13 PERFORMANCE TESTS 56. VSWR (Cont.) Equipment (Cont. ): Phase-Magnitude Display . . . . . . . «e. . e e e e eee e e e ee e e e. HP 8412A Harmonic Frequency Converter . . . . . . 2 2 444444444444 220 HP 8411A S-Parameter Test Set . . . . . 2 2 4° 240444444444 440420 0 HP 8745A Universal Extension . . . . . . . . . . . . . . . . . e eee e e e . . . HP11604A Transmission Kit . . ee... HP11651A Accessory Kit . . . . 2. 2 2 424444444444 441... . HP11570A Cable Assembly (3) . . . . ee... HP10503A Cable Assembly . . . . . . . . . . . . . . . . . . ae ae e a e e. . í HP11b500A BNC CABLE ASSY > | \ BLANKING | VTO SWEEP a ny REF CHAN DIRECT am [| a © GENERATOR/SWEEPER TEST CHAN DIRECT — —@ я) RF OUT NETWORK | PHASE-MAGNITUDE ANALYZER DISPLAY ZFI. CABLEL 3 1” CABLE REFLECTED — 1 FT. CABLE SHOX! A Ho ——— —— AMPLIFIER — SOURCE LOAD} Ue SPLITTER | in our № — — — — — — | —& 3 — [J 50Q TERMINATION Figure 5. VSWR Test Setup: 1 to 110 MHz Procedure: 1. Connect the equipment as shown in Figure 5. Set the generator/sweeper for a —10 dBm signal, sweeping from 1 to 110 MHz. 2. Connect the short to the directional bridge and calibrate the network analyzer for a 0 dB return loss reference on the display (use the center horizontal graticule line). 3. Remove the short from the directional coupler, attach the coupler to amplifier INPUT (terminate OUTPUT with 50 ohms). 4. Decrease the display reference level to —10 dB (the center horizontal graticule line now repre- sents a return loss of 10 dB). The measured return loss should be as shown below: INPUT VSWR, 1 to 110 MHz: 8447D, >9.6 dB: 9.6 dB 8447F PRE AMP, >9.6 dB: 9.6 dB 8447E, >8.8 dB: 8.8 dB 8447F POWER AMP, >8.8 dB: 8.8 dB Page 14 Model 8447D/E/F PERFORMANCE TESTS 56. VSWR (Cont.) 5. Measure return loss at amplifier OUTPUT (terminate INPUT with 50 ohms). The measured return loss should be greater than 8.8 dB. OUTPUT VSWR, 1 to 110 MHz: 8.8 dB NETWORK ANALYZER {== SWEEP OSCILLATOR PHASE-MAGNITUDE i o DISPLAY о с обо! = o 00 = =oo| @-00 | a TYPE N CABLE ASSEMBLY HARMONIC FREQUENCY * CONVERTER RE | S-PARAMETER TEST SET ON ) — — 4 UNIVERSAL EXTENSION POWER METER AMPLIFIER UNDER TEST 500 [<=] OUT TERMINATION o MOUNT reel} e o (a —l ] Figure 6. VSWR Test Setup: 0.11 to 1.3 GHz 6. Connect the equipment as shown in Figure 6. Set the sweep oscillator for a leveled CW signal, sweeping from 110 to 220 MHz. Connect the power meter to s-parameter test set INPUT PORT A and set the generator/sweeper’s output level for —15 dBm as read on the power meter. 7. Disconnect the power meter from the test set and connect a short to INPUT PORT A (measuring S11 at INPUT PORT A). Calibrate the analyzer for a 0 dB return loss reference on the display (use the center horizontal graticule line). Note TEST CHANNEL GAIN at the reference: Reference TEST CHAN. GAIN, 110 to 220 MHz: dB 8. Disconnect the short from INPUT PORT A. Terminate amplifier OUTPUT with 50 ohms. Connect INPUT PORT A to amplifier INPUT. Model 8447D/E/F Page 15 PERFORMANCE TESTS 56. VSWR (Cont.) 9. Set TEST CHANNEL GAIN 10 dB above the reference in step 7. The center horizontal graticule line now represents a return loss of 10 dB. The measured return loss should be as shown below: INPUT VSWR, 110 to 220 MHz: 8447D, >9.6 dB: 9.6 dB 8447F PRE AMP, >9.6 dB: 9.6 dB 8447E, >8.8 dB: 8.8 dB 8447F POWER AMP, >8.8 dB: 8.8 dB 10. Repeat steps 8 and 9, measuring return loss at amplifier OUTPUT (terminate amplifier INPUT with 50 ohms). The measured retum loss should be greater than 8.8 dB: OUTPUT VSWR, 110 to 220 MHz: 8.8 dB 11. Set the sweep oscillator to sweep each of the ranges shown below, repeating steps 7 through 10 for each range. Reference: 8447D INPUT, 8447E INPUT, Sweep Range TEST CHAN. 8447F PRE 8447F POWER OUTPUT GAIN AMP INPUT AMP INPUT 220 to 440 MHz dB 96dB_ 88dB__ 8.8 dB 440 to 880 MHz dB 9.6 dB 8.8 dB 8.8 dB 880 to 1300 MHz dB 9.6 dB 8.8 dB 8.8 dB 57. Distortion and Reverse Isolation Specifications: 8447D 8447E 8447F PRE AMP POWER AMP PRE AMP POWER AMP Harmonic —30 dB for —30 dB for Distortion +10 dBm output +10 dBm output Reverse Isolation >40 dB >40 dB >40 dB >40 dB Description: A fixed, CW signal at 400 MHz is filtered and applied to amplifier INPUT. Amplifier OUTPUT is connected to a spectrum analyzer, and the analyzer is used to check the second and third harmonic levels. Reverse isolation is checked by applying a known signal level to amplifier OUTPUT and mea- suring it at amplifier INPUT. Page 16 Model 8447D/E/F PERFORMANCE TESTS 57. Distortion and Reverse Isolation (Cont.) Equipment: Spectrum Analyzer . . . . . . . . . . . . . . . . . +... . . e. HP141T/8552A/8555A Sweep Oscillator . . . . . . © 2 2. e eee eee ee e e e e e HP 8620 A/8621A 400 MHz Low Pass Filter . . . . Cir- mate FLT/2 Series Cable Assembly . . . . . . 0.0.0.0, eee eee e ee e e e e e . . . HP 10503A Adapter AAA ae aa e e e e e e e e e e e UG-201A/U 10 dB Attenuator ВЕ... НР 84918-10 Adapter ae ae eee aa e eee ae a a e e ao UG- 349A/U Cable Assembly . . . 7 4. HP11500A SPECTRUM ANALYZER SWEEP OSCILLATOR = o AMPLIFIER o a—] o UNDER TEST LODO O || ADAPTER о о © о oO] = о ol | RF vo= = ~oo|9=00_ cee JJoe@@®l ||" un + © —_— — °° о м | our 2° d O +!” | ТУРЕМ 10 dB ATTENUATOR | CABLE ASSY | — — — À В BNC CABLE ASSY FILTER ADAPTER Figure 7. Distortion and Reverse Isolation Test Setup Procedure: 1. To check distortion, connect the equipment as shown in Figure 7. Set the sweep oscillator for a fixed, 400 MHz CW signal. 2. Set the spectrum analyzer’s input attenuator as shown below; adjust the controls to display 400 through 1200 MHz. NOTE The signal into the analyzer's input mixer must be low enough to eliminate harmonic distortion in the analyzer. 3. Set the sweep oscillator’s output level for the following signal levels out of the amplifier (read on the analyzer). Signal Level Analyzer Input Atten. 8447E: +10 dBm 50 dB 8447F POWER AMP: +10 dBm 50 dB 4. Note the level of the second harmonic (at 800 MHz) and the third harmonic (at 1200 MHz). The harmonic signal levels should be >30 dB below the fundamental: Harmonic Distortion, 30 dB down: 30 dB Model 8447D/E/F PERFORMANCE TESTS Page 17 57. Distortion and Reverse Isolation (Cont.) 5. To check reverse isolation, disconnect the oscillator and the analyzer from the amplifier, reduce the oscillator’s output level, then connect the oscillator to the spectrum analyzer. 6. Set the oscillator’s output level for a 0 dBm signal as read on the analyzer. Connect the analyzer to amplifier INPUT; connect the oscillator to amplifier OUTPUT. 7. Read the level of feed-through directly on the analyzer; it should be below —40 dBm: Reverse Isolation, >40 dB down: —40 dBm 58. Noise Figure Specifications: Noise Figure: Description: < 8.5 dB (for 8447D PRE AMP and 8447F PRE AMP). Noise figure is checked at 100 MHz by inserting a known amount of excess noise into the amplifier under test; the known noise is then compared to the amplifier’s noise level with a noise figure meter. Noise is checked at 1200 MHz using a 1300 MHz signal source and a mixer to convert the noise to 100 MHz; then it is measured with the meter. Equipment: Noise Figure Meter . VHF Noise Source UHF Noise Source Sweep Oscillator . | Double Balanced Mixers . HP 342A HP 343A . HP 349A HP 8620A/8621 À SL 2513/2523 50 ohm Termination HP 908A Amplifier . . . . HP 8447D Power Meter . HP 432A/478A Adapter . . . . . UG-491/U Cable Assembly (5) HP 10503A Adapter (2) . UG-201A/U NOISE FIGURE METER AMPLIFIER | UNDER TEST O 9 + | in| }out o o VHF NOISE | SOURCE ! BNC INPUT DIODE ee CABLE AMPLIFIER | ° ASSY IN ep N CONNECT DIRECTLY OUT USING BNC ADAPTER BNC CABLE ASSY Figure 8. Noise Figure Test Setup: 100 MHz Page 18 Model 8447D/E/F PERFORMANCE TESTS 58. Noise Figure (Cont.) NOISE FIGURE METER A 9 ¢ AMPLIFIER _ SWEEP OSCILLATOR UNDER TEST AMPLIFIER o o ! INPUT GAS TUBE 18 OUT RF | OUT BNC | BNC CABLE (STEP 3) | — CABLE ASS Y — ASS Y ADAPTER A BNC | | NOISE CABLE ASSY power MOUNT METER © iy DOUBLE = ) BALANCED == NOISE MIXER o SOURCE о Of Figure 9. Noise Figure Test Setup: 1200 MHz Procedure: 1. Connect the equipment as shown in Figure 8. Calibrate the noise figure meter. Check the amplifier’s noise figure at 100 MHz (or 105 MHz); it should be less than 8.5 dB: 100 MHz: 8.5dB 2. Connect the equipment as shown in Figure 9. Set the sweep oscillator for a fixed, CW signal at 1300 MHz; set the signal level out of the oscillator for +10 dBm read on the power meter. 3. Disconnect the power meter from the oscillator and connect the oscillator to the mixer. 4. Set the noise figure meter to measure noise at 100 MHz; calibrate the meter. NOTE If the noise figure meter being used has a 105 MHz input frequency, set the sweep oscillator (in step 2) to 1305 MHz. 5. Check the amplifier’s noise figure; it should be less than 8.5 dB: 1200 MHz: 8.5 dB Model 8447D/E/F Page 19 ADJUSTMENT 59. Power Supply Voltage Check and Adjustment Description: To insure that the amplifier gives proper gain, the power supply is adjusted to 20 volts +0.1 volt. Equipment: Digital Voltmeter . . . . . . . . . . Aa e a e a e e e e e . . HP3440A/3444A RMS Voltmeter . . . . . . . . . . . . . + « + . +. +. +. e e e e e e e e . . HP3400A Cable Assembly (w/test clips) . . . . . . . . . . . . . . . . e . e e e . HP10501A Adapter . . . . . . . 2 2. eee e a ea ea HP 10111A DIGITAL VOLTMETER of J sg TOP VIEW am sc o COVER REMOVED AMPLIFIER UNDER TEST yd ADAPTER. ^^! | TO CHASSIS BNC CABLE No р TO PIN 14 OF XAl Figure 10. Power Supply Voltage Adjustment Test Setup Procedure: 1. Connect the test setup in Figure 10. Set the digital voltmeter to measure +20 volts dc. 2. Adjust A1R9 VOLT ADJ for a digital voltmeter reading of +20 V +0.1 Vdc DVM: +9.9 +20.1 Vdc 3. Remove the digital voltmeter from the amplifier and connect the RMS voltmeter to XA1l pin 14. The ripple voltage should be as shown below. 8447D <0.35 mVrms: 0.35 mVrms 8447E <0.50 mVrms: 0.50 mVrms 8447F <0.50 mVrms: 0.50 mVrms Page 20 60. REPLACEABLE PARTS 61. Tables 4, 5 and 6 list parts in alpha-numerical order of their reference designations. It is important that you refer to the table that documents the instrument being serviced. Cabinet parts for all three amplifiers are listed in Figure 11. Figure 12 lists the parts that make up the Type N connector used in amplifier options 010 and 011. 62. ORDERING INFORMATION 63. To obtain replacement parts, address order or inquiry to your local Hewlett-Packard field office Model 8447D/E/F (see list at rear of this manual for address). Identify parts by their Hewlett-Packard part numbers. 64. To obtain a part that is not listed, include: С. Instrument model number. Instrument serial number Description of the part. Function and location of the part. Table 3. Reference Designations and Abbreviations assembly motor battery capacitor coupler diode delay line device signaling (lamp) misc electronic part amperes automatic frequency control amplifier beat frequency oscilla- tor beryllium copper binder head bandpass brass backward wave oscilla- tor counterclockwise ceramic cabinet mount only coefficient common composition complete connector cadmium plate cathode-ray tube clockwise deposited carbon drive electrolytic encapsulated external farads flat head Fillister head fixed giga (109) germanium glass ground(ed) IMPG INCD INCL INS INT LH LIN LK WASH LOG LPF MEG MET FLM MET OX MFR MHz MINAT MOM MOS MTG MY N/C NI PL REFERENCE DESIGNATORS fuse P Filter Q jack R relay RT inductor S loud speaker T meter TB microphone TP mechanical part U ABBREVIATIONS henries N/O hardware NOM hexagonal NPO mercury hour(s) Hertz NPN intermediate freq impregnated NRFR incandescent include(s) insulation(ed) NSR internal OBD kilo = 1000 OH left hand ox linear taper Р lock washer PC logarithmic taper PF low pass filter PH BRZ milli = 10-3 PHL meg = 106 PIV metal film metallic oxide PNP manufacturer mega Hertz P/O miniature POLY momentary PORC metalized POS substrate POT mounting PT mylar PWV nano (1079) normally closed RECT neon RF RH nickel plate plug transistor resistor thermistor switch transformer terminal board test point integrated circuit normally open nominal negative positive zero (zero tem- perature coef- ficient) negative-positive- negative not recommended for field re- placement not separately replaceable order by description oval head oxide peak printed circuit picofarads = 10-12 farads phosphor bronze Phillips peak inverse voltage positive-negative- positive part of polystrene porcelain position(s) potentiometer peak-to-peak point peak working volt- age rectifier radio frequency round head or right hand N<XE RMO RMS RWV S-B SCR SECT SEMICON S SIL SPG SPL SST STL TA TGL THD TOL TRIM TWT VAR VDCW W/ WIV WW W/O vacuum tube, neon bulb, photocell, etc. voltage regulator cable socket crystal tuned cavity, network rack mount only root-mean square reverse working voltage slow-blow screw selenium section(s) semiconductor silicon silver slide spring special Stainless steel split ring steel tantalum time delay toggle thread titanium tolerance trimmer traveling wave tube micro = 10-6 variable dc working volts with watts working inverse voltage wirewound without Model 8447D/E/F Table 4. 8447D Replaceable Parts Page 21 Reference HP Part С Le Mfr Mfr Part a Qty Description Designation Number D Code Number Al 08447-60011 о 1 BOARD ASSY: POWER SUPPLY 28480 08447-60011 A1C1 0150-0024 7 13 C:FXD CER 0.02 UF +80—20% 600 VDCW 71590 TYPE DD 203 A1C2 0180-0228 6 1 C:FXD ELECT 22 UF 10% 15VDCW 56289 150D226X9015B2-DYS A2C3 0160-0162 5 1 C:FXD MY 0.022 UF 10% 200VDCW 56289 192P22392-PTS A2C4 80-0116 1 1 C:FXD ELECT 6.8 UF 10% 35VDCW 56289 150D685X9035B2-DYS А1С5 0180-1819 3 1 C:FXD ELECT 100 UF +75—10% 50VDCW 28480 0180-1819 A1CR1 1901-0159 3 4 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICR2 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 A1CR3 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICR4 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICRS 1902-3036 3 1 DIODE:BREAKDOWN 3.16V 5% 02037 SZ10939-38 AICR6 1902-0761 5 1 DIODE :BREAKDOWN 5.3 to 6.5V 12954 1N821 A1CR7 1901-0025 2 2 DIODE:SILICON 100MA/1V 07263 FD 2387 A1CRS8 1902-3268 3 1 DIODE:BREAKDOWN:26.1V 5% 28480 1902-3268 AICR9 1884-00 2 1 THYRISTER-SCR TO-5 VRRM=100 01921 SCR1400 A1CR10 1901-0025 2 DIODE:SILICON 100MA/1V 07263 FD 2387 AlF1 2110-0012 0 2 FUSE:0.5 AMP 250V 04703 312.500 AlF1 2110-026 9 1 CLIP:FUSE 0.250" DIA 91506 6008-32CN A1Q1 1853-0012 4 1 TSTR:SI PNP 80131 2N2904A A1Q2 1854-0022 8 1 TSTR:SI NPN 07263 S17843 A1Q3 1854-0071 7 3 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 A1Q4 1854-0071 7 TSTR:S1 NPN (SELECTED FROM 2N3704) 28480 1854-0071 AlQ5 1854-0071 7 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 AlR1 0757-0836 5 2 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 Al1R2 0757-0278 9 1 R:FXD MET FLM 1.78K OHM 1% 1/8W 28480 0757-0278 A1R3 0757-0836 5 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 Al1RA 0811-1668 9 1 R:FXD WW 1.5 OHM 5% 2W 28480 0811-1668 A1R5 0698-0089 4 1 R:FXD MET FLM 1780 OHM 1% 1/2W 28480 0698-0089 A1R6 0698-0083 8 1 R:FXD MET FLM 1.96K OHM 1% 1/8W 28480 0698-0083 A1R7 0698-3440 7 1 R:FXD MET FLM 196 OHM 1% 1/8W 28480 0698-3440 Al1R8 0757-0416 7 1 R:FXD MET FLM 511 OHM 1% 1/8W 28480 0757-0416 A1R9 2100-1758 3 1 R: VAR WW 1K OHM 5% TYPE V 1W 28480 2100-1758 A1R10 0698-3154 0 1 R:FXD MET FLM 4.22K OHM 1% 1/8W 28480 0698-3154 AlR11 0757-1094 9 1 R:FXD MET FLM 1,47K OHM 1% 1/8W 28480 0757-1094 AlR12 0698-3442 9 1 R:FXD MET FLM 237 OHM 1% 1/8W 28480 0698-3442 Al1RI13 0757-0180 2 1 R:FXD MET FLM 31.6 OHM 1% 1/8W 28480 0757-0180 AlR14 0757-0401 о R:FXD MET FLM 100 OHM 1% 1/8W 28480 0757-0401 AITBI1 08447-20011 6 1 BOARD:BLANK PC 28480 08447-20011 Cl 0180-2272 4 1 C:FXD ELECT 850 UF +50—10% 75V DCW 56289 36D851F075AA2A DQB C2 0160-2049 1 1 C:FXD CER FEED-THRU 5000 PF +80—20% 28480 0160-2049 C3 0180-0291 3 1 C:FXD ELECT 1.0 UF 10% 35VDCW 56289 150D105X9035A2-DYS DS1 2140-0244 4 1 LAMP:GLOW MINIATURE 95V 87034 AlH Fl 2110-0012 1 FUSE:0.5 AMP 250V 04703 312.500 J1 1251-2357 8 1 SOCKET :3-PIN MALE POWER 82389 EAC-301 (P/O REAR PANEL J2 PART OF W2 J3 PART OF W3 Ja PART OF W4 JS PART OF W5 Ll 9100-1618 1 2 COIL:MOLDED CHOKE 5.60 UH 28480 9100-1618 L2 9100-1618 1 COIL:-MOLDED CHOKE 5.60 UH 28480 9100-1618 L2 (OPT'S 001 AND 011 ONLY) MP1 08447-00005 6 1 INSULATOR:TOP COVER 28480 08447-00005 MP2 08447-00028 3 1 SUPPORT:AMPLIFIER 28480 08447-00028 MP2 (OPT'S 001 AND 011 ONLY) Ql 1854-0063 7 1 TSTR:SI NPN 80131 2N3055 R1 0683-2735 о 1 R:FXD COMP 27K OHM 5% 1/4W 01121 CB 2735 51 3101-2195 7 1 ОВ DPST-NO ALTNG 10.5A 04757 53-67600-123 S1 0590-0012 5 2 NUT:KNURLED 15/32-32 04009 899U-3 S2 3101-1234 3 1 SWITCH:SLIDE DPDT 82389 11A-1242 T1 9100-2894 7 1 TRANSFORMER:POWER 28480 9100-2894 Ul, U2 0960-2013 5 HYBRID MC:PRE-AMPL 0.1—1300 MHZ 28480 0960-2013 Ul, U2 (OPT'S 001 AND 011 ONLY) W1 8120-1348 5 1 CABLE ASSY:POWER, DETACHABLE 70903 KHS-7041 W2 08447-20002 5 1 CABLE ASSY : TYPE N INPUT 28480 08447-20002 (OPT:S 010 AND 011) w2 08447-20006 9 1 CABLE ASSY:BNC INPUT 28480 08447-20006 W3 08447-20003 6 1 CABLE ASSY:TYPE N OUTPUT 28480 08447-20003 (OPT'S 010 AND O11) W3 08447-20007 О 1 CABLE ASSY:BNC OUTPUT 28480 08447-20007 W4 08447-20004 7 1 CABLE ASSY ; TYPE N INPUT (OPT 011) 28480 08447-20004 W4 08447-20008 1 1 CABLE ASSY:BNC INPUT (OPT 001) 28480 08447-20008 W5 08447-20005 8 1 CABLE ASSY: TYPE N OUTPUT (OPT 011) 28480 08447-20005 WS5 08447-20009 2 1 CABLE ASSY:BNC OUTPUT (OPT 001) 28480 08447-20009 W6 08447-20014 9 1 CABLE ASSY: JUMPER (OPT 011 ONLY) 28480 08447-20014 XF1 FUSEHOLDER (INCLUDES THE FOLLOWING PARTS) XF1MP1 2110-0564 8 1 FUSEHOLDER BODY 12A MAX FOR UL 28480 2110-0564 XF1MP2 2110-0565 9 1 FUSEHOLDER CAP 12A MAX FOR UL 28480 2110-0565 XF1MP3 2110-0569 3 1 NUT-FUSEHOLDER THREAD 28480 2110-0569 xXQ1 1200-0043 8 1 INSULATOR:TSTR MOUNTING (TO-3) 71785 293011 2190-0037 9 1 WASHER:LOCK SST FOR 1/2 THREAD 78189 1224-08 0360-0368 7 1 TERMINATION:SOLDER STUD 78189 2168-12-01 0900-0016 8 1 “O" RING 0.688" OD 00000 BD Page 22 Model 8447D/E/F Table 5. 8447E Replaceable Parts Reference HP Part os Mfr Mfr Part Co Qty Description Designation Number Code Number Al 08447-60011 0 1 BOARD ASSY: POWER SUPPLY 28480 08447-60011 AlCl 0150-0024 7 13 C:FXD CER 0.02 UF +80—20% 600 VDCW 71590 TYPE DD 203 A1C2 0180-0228 6 1 C:FXD ELECT 22 UF 10% 15VDCW 56289 150D226X9015B2-DYS A2C3 0160-0162 5 1 C:FXD MY 0.022 UF 10% 200VDCW 56289 192P22392-PTS A2C4 0180-0116 1 1 C:FXD ELECT 6.8 UF 10% 35VDCW 56289 150D685X9035B2-DYS А1С5 0180-1819 3 1 C:FXD ELECT 100 UF +75—10% 50VvDCW 28480 0180-1819 A1CRI1 1901-0159 3 4 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 A1CR2 1901-0159 3 DIODE: SILICON 0.75A 400PIV 02037 SR1358-4 A1CR3 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 A1CR4 1901-0159 3 DIODE :SILICON 0.75A 400PIV 02037 SR1358-4 AICRS 1902-3036 3 1 DIODE:BREAKDOWN 3.16V 5% 02037 SZ10939-38 AICR6 1902-0761 5 1 DIODE:BREAKDOWN 5.9 to 6.5V 12954 1N821 AICR7 1901-0025 2 2 DIODE :SILICON 100MA/1V 07263 FD 2387 AICRB8 1902-3268 3 1 DIODE:BREAKDOWN:26.1V 5% 28480 1902-3268 AICR9 1884-0073 2 1 THYRISTER-SCR TO-5 VRRM=100 01921 SCR1400 AICRIO 1901-0025 2 DIODE:SILICON 100MA/1V 07263 FD 2387 AlF1 2110-0012 о 2 FUSE:0.5 AMP 25 04703 312.500 AlF1 2110-0269 9 1 CLIP:FUSE 0.250" DIA 91506 6008-32CN AlQl 1853-0012 4 1 TSTR:SI PNP 80131 2N2904A A1Q2 1854-0022 8 1 TSTR:SI NPN 07263 S17843 A1Q3 1854-0071 7 3 TSTR:S!| NPN (SELECTED FROM 2N3704) 28480 1854-0071 Al1Q4 1854-0071 7 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 Al1Q5 1854-0071 7 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 A1R1 0757-0836 5 2 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 A1R2 0757-0278 9 1 R:FXD MET FLM 1.78K OHM 1% 1/8W 28480 0757-0278 A1R3 0757-0836 5 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 AlR4 0811-1668 9 1 R:FXD WW 1.5 OHM 5% 2W 28480 0811-1668 A1R5 0698-0089 4 1 R:FXD MET FLM 1780 OHM 1% 1/2W 28480 0698-0089 A1R6 0698-0083 8 1 R:FXD MET FLM 1.96K OHM 1% 1/8W 28480 0698-0083 A1R7 0698-3440 7 1 R:FXD MET FLM 196 OHM 1% 1/8W 28480 0698-3440 Al1RS8 0757-0416 7 1 R:FXD MET FLM 511 OHM 1% 1/8W 28480 0757-0416 A1R9 2100-1758 3 1 R: VAR WW 1K OHM 5% TYPE V 1W 28480 2100-1758 A1R10 0698-3154 о 1 R:FXD MET FLM 4.22K OHM 1% 1/8W 28480 0698-3154 Al1RI11 0757-1094 9 1 R:FXD MET FLM 1.47K OHM 1% 1/8W 28480 0757-1094 Al1RI12 0698-3442 9 1 R:FXD MET FLM 237 OHM 1% 1/8W 28480 0698-3442 A1R13 0757-0180 2 1 R:FXD MET FLM 31.6 OHM 1% 1/8W 28480 0757-0180 AlR14 0757-0401 о R:FXD MET FLM 100 OHM 1% 1/8W 28480 0757-0401 Al1TEI1 08447-20011 6 1 BOARD:BLANK PC 28480 08447-20011 Cl 0180-2272 4 1 C:FXD ELECT 850 UF +50—10% 75VDCW 56289 36D851F075AA2A DQB C2 0160-2049 1 1 C:FXD CER FEED-THRU 5000 PF +80—20% 28480 0160-2049 C3 0180-0291 3 1 C:FXD ELECT 1.0 UF 10% 35VDCW 56289 150D105X9035A2-DYS DS1 2140-0244 4 1 LAMP:GLOW MINIATURE 95V 87034 AlH Fl 2110-0012 1 FUSE:0.5 AMP 250V 04703 312.500 Jl 1251-2357 8 1 SOCKET:3-PIN MALE POWER 82389 EAC-301 RECEPTACLE Jl PART OF REAR PANEL) J2 ART OF W2 J3 PART OF W3 Ll 9100-1618 1 1 COIL:-MOLDED CHOKE 5.60 UH 28480 9100-1618 MP1 08447-00005 6 1 INSULATOR: TOP COVER 28480 08447-00005 Ql 1854-0063 7 1 TSTR:SI NPN 80131 2N3055 R1 0683-2735 О 1 R:FXD COMP 27K OHM 5% 1/4W 01121 CB 2735 Sil 3101-2195 7 1 ARTE DPST-NO ALTNG 10.5A 04757 53-67600-123 A S1 0590-0012 5 2 NUT: KNURLED 15/32-32 04009 899U-3 S2 3101-1234 3 1 SWITCH: SLIDE DPDT o REAR PANEL) 82389 11A-1242 T1 9100-2894 7 1 TRANSFORMER :POWER 28480 9100-2894 Ul 0960-2014 6 1 HYBRID MC:POWER AMPL 0.1-1300MHZ 28480 0960-2014 wil 8120-1348 5 1 CABLE ASSY:POWER, DETACHABLE 70903 KHS-7041 W2 08447-20002 5 1 CABLE ASSY:TYPE N INP 28480 08447-20002 W2 (OPTION 010) W2 08447-20006 9 1 CABLE ASSY:BNC INPUT 28480 08447-20006 W2 (STANDARD) W3 08447-20003 6 1 CABLE ASSY: TYPE N OUTPUT 28480 08447-20003 W3 (OPTION 010) W3 08447-20007 о 1 CABLE ASSY:BNC OUTPUT 28480 08447-20007 W3 (STANDARD) XF1 FUSEHOLDER (INCLUDES THE FOLLOWING PARTS) XF1MP] 2110-0564 8 1 FUSEHOLDER BODY 12A MAX FOR UL 28480 2110-0564 XF1MP2 2110-0565 9 1 FUSEHOLDER CAP 12A MAX FOR UL 28480 2110-0565 XF1MP3 2110-0569 3 1 NUT-FUSEHOLDER THREAD 28480 2110-0569 ХО! 1200-0043 8 1 INSULATOR: TSTR MOUNTING (TO-3) 71785 29301 0360-0368 7 1 TERMINATION:SOLDER STUD 78189 2168-12-01 0900-0016 8 1 “Oo” RING:0.688" OD 00000 D 2190-0037 9 1 WASHER: LOCK INT.FOR 0.500" THREAD 78189 1224-08 Model 8447D/E/F Page 23 Table 6. 8447F Replaceable ‘Parts Reference HP Part C o Mfr Mfr Part Co Qty Description Designation Number D Code Number Al 08447-60011 0 1 BOARD ASSY: POWER SUPPLY 28480 08447-60011 А1С1 0150-0024 7 13 C:FXD CER 0.02 UF +80—20% 600 VDCW 71590 TYPE DD 203 A1C2 0180-0228 6 1 C:FXD ELECT 22 UF 10% 15VDCW 56289 150D226X9015B2-DYS A2C3 0160-0162 5 1 C:FXD MY 0.022 UF 10% 200VDCW 56289 192P22392-PTS A2C4 0180-0116 1 1 C:FXD ELECT 6.8 UF 10% 35VDCW 56289 150D685X9035B2-DYS A1C5 0180-1819 3 1 C:FXD ELECT 100 UF +75—10% 50VDCW 28480 0180-1819 AICRI 1901-0159 3 4 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICR2 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICR3 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICR4 1901-0159 3 DIODE:SILICON 0.75A 400PIV 02037 SR1358-4 AICRS 1902-3036 3 1 DIODE:BREAKDOWN 3.16V 5% 02037 SZ10939-38 A1CR6 1902-0761 5 1 DIODE :BREAKDOWN 5.9 to 6.5V 12954 1N821 A1CR7 1901-0025 2 2 DIODE :SILICON 100MA/1V 07263 FD 2387 A1CRS8 1902-3268 3 1 DIODE:BREAKDOWN:26.1V 5% 28480 1902-3268 A1CR9 1884-0073 2 1 THYRISTER-SCR TO-5 VRRM=100 01921 SCR1400 A1CR10 1901-0025 2 DIODE:SILICON 100MA/1V 07263 FD 2387 A1F1 2110-0012 0 2 FUSE:0.5 AMP ov 04703 312.500 AlF1 2110-0269 9 1 CLIP:FUSE 0.250" DIA 91506 6008-32CN AlQl 1853-0012 4 1 TSTR:SI PNP 80131 2N2904A A1Q2 1854-0022 8 1 TSTR:SI NPN 07263 S17843 A1Q3 1854-0071 7 3 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 A1Q4 1854-0071 7 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 A1Q5 1854-0071 7 TSTR:SI NPN (SELECTED FROM 2N3704) 28480 1854-0071 Al1RI1 0757-0836 5 2 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 A1R2 0757-0278 9 1 R:FXD MET FLM 1.78K OHM 1% 1/8W 28480 0757-0278 A1R3 0757-0836 5 R:FXD MET FLM 7.50K OHM 1% 1/2W 28480 0757-0836 A1RA4 0811-1668 9 1 R:FXD WW 1.5 OHM 59% 2W 28480 0811-1668 A1RS 0698-0089 4 1 R:FXD MET FLM 1780 OHM 1% 1/2W 28480 0698-0089 A1RG 0698-0083 8 1 R:FXD MET FLM 1.96K OHM 1% 1/8W 28480 0698-0083 A1R7 0698-3440 7 1 R:FXD MET FLM 196 OHM 1% 1/8W 28480 0698-3440 Al1RS8 0757-0416 7 1 R:FXD MET FLM 511 OHM 1% 1/8W 28480 0757-0416 AlR9 2100-1758 3 1 R: VAR WW 1K OHM 5% TYPE V 1W 28480 2100-1758 A1RIO 0698-3154 О 1 R:FXD MET FLM 4.22K OHM 1% 1/8W 28480 0698-3154 AlR11 0757-1094 9 1 R:FXD MET FLM 1.47K OHM 1% 1/8W 28480 0757-1094 Al1RI12 0698-3442 9 1 R:FXD MET FLM 237 OHM 1% 1/8W 28480 0698-3442 A1R13 0757-0180 2 1 R:FXD MET FLM 31.6 OHM 1% 1/8W 28480 0757-0180 A1R14 0757-0401 О R:FXD MET FLM 100 OHM 1% 1/8W 28480 0757-0401 AITBI1 08447-20011 6 1 BOARD:BLANK PC 28480 08447-20011 Cl 0180-2272 4 1 C:FXD ELECT 850 UF +50—10% 75VDCW 56289 36D851F 075AA2A DQB C2 0160-2049 1 1 C:F XD CER FEED-THRU 5000 PF +80—20% 28480 0160-2049 C3 0180-0291 3 1 C:FXD ELECT 1.0 UF 10% 35VDCW 56289 150D105X9035A2-DYS DS1 2140-0244 4 1 LAMP:GLOW MINIATURE 95V 87034 AlH Fl 2110-0012 1 FUSE:0.5 AMP 250V 04703 312.500 Jl 1251-2357 8 1 SOCKET:3-PIN MALE POWER 82389 EAC-301 RECEPTACLE J1 (PART OF REAR PANEL) J2 ART OF W2 J3 PART OF W3 Ja PART OF W4 J5 PART OF W5 Ll 9100-1618 1 2 COIL:MOLDED CHOKE 5.60 UH 28480 9100-1618 L2 9100-1618 1 COIL:MOLDED CHOKE 5.60 UH 28480 9100-1618 MP1 08447-00005 6 1 INSULATOR: TOP COVER 28480 08447-00005 MP2 08447-00028 3 1 SUPPORT:AMPLIFIER 28480 08447-00028 Ql 1854-0063 7 1 TSTR:SI NPN 80131 2N3055 R1 0683-2735 0 1 R:FXD COMP 27K OHM 5% 1/4W 01121 CB 2735 51 3101-2195 7 1 SWITCH-PB DPST-NO ALTNG 10.5A 04757 53-67600-123 250VAC S1 0590-0012 5 2 NUT:KNURLED 15/32-32 04009 899U-3 52 3101-1234 3 1 SWITCH: SLIDE DPD 82389 11A-1242 S2 (PART OF REAR PANEL) T1 9100-2894 7 1 TRANSFORMER :POW 28480 9100-2894 Ul 0960-2014 6 1 HYBRID MC:POWER AMPL 0.1-1300 MHZ 28480 0960-2014 U2 0960-2013 5 1 HYBRID MC:PRE-AMPL 0.1-1300 MHZ 28480 0960-2013 W1 8120-1348 5 1 CABLE ASSY :POWER, DETACHABLE 70903 KHS-7041 W2 08447-20002 5 1 CABLE ASSY: TYPE N INPUT (OPT 010) 28480 08447-20002 W2 08447-20006 9 1 CABLE ASSY:BNC INPUT 28480 08447-20006 W3 08447-20003 6 1 CABLE ASSY:TYPE N OUTPUT (OPT 010) 28480 08447-20003 W3 08447-20007 0 1 CABLE ASSY:BNC OUTPUT 28480 08447-20007 W4 08447-20004 7 1 CABLE ASSY: TYPE N INPUT (OPT 010) 28480 08447-20004 W4 08447-20008 1 1 CABLE ASSY:BNC INPUT 28480 08447-20008 \\ 5 08447-20005 8 1 CABLE ASSY: TYPE N OUTPUT (OPT 010) 28480 08447-20005 W5 08447-20009 2 1 CABLE ASSY:BNC OUTPUT 28480 08447-20009 W6 08447-20014 9 1 CABLE ASSY: JUMPER (OPT 010 ONLY) 28480 08447-20014 XF1 FUSEHOLDER (INCLUDES THE FOLLOWING PARTS) XF1MP1 2110-0564 8 1 FUSEHOLDER BODY 12A MAX FOR UL 28480 2110-0564 XF1MP2 2110-056 9 1 FUSEHOLDER CAP 12A MAX FOR UL 28480 2110-0565 XF1MP3 2110-0569 3 1 NUT-FUSEHOLDER THREAD 28480 2110-0569 XQ1 1200-0043 8 1 INSULATOR:TSTR MOUNTING (TO-3) 71785 293011 0360-0368 7 1 TERMINATION:SOLDER STUD 78189 2168-12-01 0900-0016 8 1 “O" RING: 0.688" OD 00000 OBD 2190-0037 9 1 WASHER:LOCKINT. FOR 0.500" THREAD 78189 1224-08 Page 24 Model 8447D/E/F 5 Index Part Number Description Qt Number P Y 1 08447-00029 DECK MAIN 2 5000-7891 SIDE COVER-BLUE GRAY 2 5000-8766 SIDE COVER-OLIVE GRAY 3 5060-0247 FRAME ASSEMBLY 4 1490-0031 STAND TILT 5 5060-0708 TOP COVER-BLUE GRAY 5 5060-8553 TOP COVER-OLIVE GRAY 6 08447-00050 PANEL REAR 7 5060-0727 FOOT ASSEMBLY 8 5000-0710 BOTTOM COVER-BLUE GRAY 8 5000-8569 BOTTOM COVER-OLIVE GRAY 9 5040-0700 HINGE 10 08447-00017 PANEL :FRONT (8447D STANDARD)-LIGHT GRAY 08447-00018 08447-00019 08447-00021 08447-00022 08447-00023 08447-00024 08447-00025 08447-00040 08447-00041 08447-00042 08447-00043 08447-00044 08447-00045 08447-00046 08447-00047 A YU A UN == © О © © 60 —) С\ |) ==* © 00 © С\ === © —} 00 —) © 00 00 > oo PANEL:FRONT (8447D OPTION 001)-LIGHT GRAY PANEL:FRONT (8447D OPTION 010)-LIGHT GRAY PANEL:FRONT (8447D OPTION 011)-LIGHT GRAY PANEL:FRONT (8447E STANDARD)-LIGHT GRAY PANEL:FRONT (8447E OPTION 010)-LIGHT GRAY PANEL:FRONT (8447F STANDARD)-LIGHT GRAY PANEL:FRONT (8447F OPTION 010)-LIGHT GRAY PANEL:FRONT (8447D STANDARD)-MINT GRAY PANEL:FRONT (8447D OPTION 001)-MINT GRAY PANEL:FRONT (8447D OPTION 010)-MINT GRAY PANEL:FRONT (8447D OPTION 011)-MINT GRAY PANEL:FRONT (8447E STANDARD)-MINT GRAY PANEL:FRONT (8447E OPTION 010)-MINT GRAY PANEL:FRONT (8447F STANDARD)-MINT GRAY PANEL:FRONT (8447F OPTION 010)-MINT GRAY Figure 11. 8447D/E/F Cabinet Parts Model 8447D/E/F Page 25 Index Part C Descrioti Index Part C Descrioti No. No. D escription No. No. D escription 1 1250-0914 7 | BODY RF CONNECTOR 5 5040-0306 0 | INSULATOR 2 1250-0915 8 | CONTACT RF CONNECTOR 6 08555-20093 | § | CONTACT JACK 3 2190-0444 1 | WASHER LOCK 7 08555-20094 | 6 | BODY BULKHEAD 4 2950-0132 | 6 | NUT HEX 8 | 08761-2027 | 4 | INSULATOR Figure 12. 8447D/E/F Type N Connector (For Options 010 and 011) Table 7. Code List of Manufacturers Mfr. No. Manufacturer Name Address Zip Code 01121 ALLEN BRADLEY CO. MILWAUKEE, WI 53204 01921 RCA SOLID STATE DIV. SOMERVILLE, NJ 08876 02037 MOTOROLA SEMICONDUCTOR PRODUCTS PHOENIX, AZ 85008 04009 ARROW, HART & HEGEMAN ELECT. CO. HARTFORD, CT 06106 04703 LITTELFUSE INC. DES PLAINES, IL 60016 04757 OAK IND. INC., SW DIV. CRYSTAL LAKE, IL 60014 07263 FAIRCHILD CAMERA & INSTR. CORP., SEMICONDUCTOR DIV. MOUNTAIN VIEW, CA 94040 12954 DICKSON ELECTRONIC CORP. SCOTTSDALE, AZ 85282 28480 HEWLETT-PACKARD CO. PALO ALTO, CA 94304 56289 SPRAGUE ELECTRIC CO. N. ADAMS, MA 01247 70903 BELDEN CORP. CHICAGO, IL 60644 71590 GLOBE UNION INC. CENTRAL LAB DIV. MILWAUKEE, WI 53201 71785 CINCH MFG. CO., DIV TRW INC. ELK GROVE VILLAGE, IL 78189 SHAKEPROOF DIV. ILLINOIS TOOL WORKS ELGIN, IL 60120 80131 ELECTRONIC INDUSTRIES ASSOCIATION WASHINGTON, DC 20006 82389 SWITCHCRAFT INC. CHICAGO, IL 60630 87034 MARCOAK INDUSTRIES ANAHEIM, CA 92803 91506 AUGAT, INC. ATTLEBORO, MA 02703 Page 26 Model 8447D/E/F xa! TOP VIEW J5* XF1 Ci ci A1F1 BOTTOM VIEW Al MP2* W4* si *DUAL AMPLIFIER VERSIONS ONLY A1R9 Q1 VOLTADJ L2* C2 Ws* Lil W3 Figure 13. Internal Views Model 8447D/E/F 65. TEST EQUIPMENT AND ACCESSORIES REQUIRED FOR TROUBLESHOOTING 66. Test Equipment and accessories required to troubleshoot the amplifier are shown in Table 2. Test Instruments other than those listed may be used provided their specifications meet or exceed those listed in Table 2. 67. GENERAL SERVICE INFORMATION 68. The part reference designator is the assembly designator plus the part designator. (Ex- ample: A1R9 is R9 on the Al Power Supply Assembly.) Refer to the parts list on Table 4, 5 or 6 for specific component description for ordering parts. Page 27 69. TROUBLESHOOTING PROCEDURE 70. First check the input and output cables. Isolate trouble to the amplifier(s) or power supply by checking the +20 volts at XAl—14 after removing the red wire from C2. If the voltage is present, replace the amplifier (re-attach the red wire to C2). If voltage is not present or incorrect, check the power supply. The voltages shown are typical with the amplifier(s) disconnected from the power supply. Equipment: Digital Voltmeter HP 3440A/344 A Cable Assembly (w/test clips) . HP 10501A Adapter ............ HP 10111A Figure 14. Al Power Supply Component Locations Model 8447D/E/F Page 28 "GONX HO L1VHS WOY4 GIMITA SY 1041№2 10 NOILY.OM 3S1MX9019 HLIM MO QYVMOL SIAOW d]d|M *Q3LON 3STMBIHLO SSTINN SOVYVIOYIIW NI SI JONVLIOVdYI ONV SWHO NI SI J3INVLS1S3{ 341815 MONAVN LTIO1A ‘3dI4LS “INITHI0H08 ATEWISSY LINJYID — — — Salon WW9v10 91IVWIHIS 7 301M MOTTA “3SVE ILIHM SILONIO “NO LIVNIISIO "EOL AUVA AVW tv Civ) “93 *2d141S HIMOYUVN 13Nvd #vad sasomna (7771 SI9VII0A 29 IV GILIINNOIS 10 IYIM on el 18 3H ST411N301 VI9WNN QIHL ONV L——9 034 HLIM JdV NMOHS SIOVLIOA ‘€ ISO S-2M 10 ‘141415 ¥301M FHL ¥IAWNN ONOIIS "SNOILVN9ISIG “SNOISUZA ‘30700 35¥8 IHL SI1411NI01 ¥IAWNN TaNwd 1N041 SISOT9N3 [ 18 Ц 14 15411 "002 №0102 №015 1538 IHL 43141 1dWY Twna NI dISA 34Y . - 149 - * ,- u 2.16 on 183 SV 3WVS 3HL SI (189 -O15-TIW) QäSN TO#1NOI TINYd O) SIN3NOdWOI CALVIIOSSY ANY ZN 2 : N . . 1 "e SS Н Tv 3002 ‘3009 #0109 3#1M SISOTINI | (> INAWISAN AV HIALYOMIYIS-— MY S$411411dWY TIV NI 0351 si 1 SNOILVN9ISIO 39N34313Y *S3LON — — — — — VSULL 'VCOOO :X(A3M4 IVINIS NMOHS SV 31L1TdWOI _ — —_ _ J¥V SLNINOJWOD d3IHLO JO SNOILVNIISIQ 1lY SI = — = —- —- ——| 1Y AlewissY d0 la ‘Be ‘¥IgWNN ATEW3SSY SIANTI ——— — — — NI NOILYN91$30 T1N4 QIALVIAINEGSY dV SITAWISSY (=== - ==) GINITLNO NIHLIM SNOILYN91$30 32N39434139 P_ | REN] | | 14 AZ | sa 7 9 E La TO № 5+ *T 2 из’ 1700-9581 1 oot L rav 50 70 Do ST 110A 43141 1dWY O 0H Lu NOSI YVdWOI “> xs 14 „7 » Eu + 6400 vest 2100-€581 143 | 00$ —_— | — 20 10 64% ts A29+ + 43141 1dwWy 83 S so vo 108 1N09 33an0s _ 1N34N9 ax ve Mes py) 249 | of go 2 » lo Ay + e mT* AUZ+ ay 1 Pel AT 0Z+ ^^ 1 \_/ | = 77 £4) 137 | oh %! 3 ord 200% ; в z 821 ) € Р ~ 1200-7581 fc oa ^1 92 го’ co O 84) OF IW | ! | 64 9( 7 91) 1N34N9 ! veo 1 < го, dvamodd Ed | | [4 < N wm — > т q LS vl AO 02+ ST DO AOS + vx vy | 6900-7581 | 10 __ —— __ {x dOLVIN938 [VX —— 1 $31 435 (11009- Lv¥80) A1ddNS #3MOd TV T НП 9 °6 ot] «оо = 21 HA 9° ©] el—, | и ¢ 2 7) = — 00 - 4 T — — oz 2 310N 335 Т LI — — 1. { ALON 335 60% + 52 ; + А < dos 05 ! ‘ ) + & : indio 43 > с > 2n < IM << INdNI 43 1Nd1NO 39 77 Em > In < M 1/3/0 2998 << << ef vos 1ndNI 19 Figure 15. Amplifier and Power Supply Circuits Model 8447D/E/F 71. MANUAL BACKDATING CHANGES 72. The following paragraphs contain information for adapting this manual to instruments for which the content does not apply directly. 73. To adapt this manual to your instrument, refer to Table 8 and make all of the manual changes listed opposite your instrument serial number. Page 29 Perform these changes in the alphabetical sequence listed. 74. If your instrument serial number is not listed on the title page of this manual, or in Table 8 be- low, it may be documented in a yellow MANUAL CHANGES supplement. For additional important information about serial number coverage, refer to INSTRUMENTS COVERED BY MANUAL. Table 8. Manual Changes by Serial Number Prefix Serial Prefix Make Manual Changes 1726A A 1644A A,B 1616A А, В, С 1529 А, 1145 А, 099ЗА А, В, С, р 75. MANUAL CHANGE INSTRUCTIONS CHANGE A Pages 21 through 23, Tables 4 through 6: Change XF1MP1 to HP Part Number 2110-0470, Check Digit 5, Qty 1, FUSEHOLDER BODY EXTR PST; BAYONET; TND, 04703, 345003-010. Change XF1MP2 to HP Part Number 2110-0465, Check Digit 8, Qty 1, FUSEHOLDER CAP EXTR PST; BAYONET; 20A, 04703, 345001-020. Change XF1MP3 to HP Part Number 2110-0467, Check Digit 0, Qty 1, FUSEHOLDER COMPONENT HEX NUT: 1/2-28, 04703, 903-070. Add XF1MP4, HP Part Number 1400-0090, Check Digit 9, Qty 1, FUSEHOLDER COMPONENT FOR USE ON, 04703, 901-002. CHANGE B Page 1, Table 1: Change Mean Gain (20°—30° C) to “26 dB +1.5 dB’’ for 8447D PRE AMP and 8447F PRE AMP. Page 9, Paragraph 55: Under Specifications, change Mean Gain (20°—30°C) to “26 dB +1.5 dB” for 8447D PRE AMP and 8447F PRE AMP. Page 30 Model 8447D/E/F CHANGE B (Cont'd) Page 11, Paragraph 55, Step 10.: Change the sentence to read: ‘‘ Add the highest and lowest gains together and divide by 2; the result is measured mean gain and should be within 1.5 dB of specified mean gain.” In step 10, under EX AMPLE, change Mean Gains as follows: Mean Gain MIN. ACTUAL MAX. 8447D 24.5 dB 27.5 dB 8447E 20.5 dB 23.5 dB 8447F PRE AMP 24.5 dB 27.5 dB 8447F POWER AMP 20.5 dB 23.5 dB CHANGE C Pages 21 through 23, Tables 4 through 6: Change first S1 entry to HP Part Number 3101-1244, Check Digit 5, Qty 1, SWITCH-PB SPDT-DB ALTNG 10.5A 250V AC, 04757, 53-55480-120/A1N. Change XF1 to 1400-0084, Check Digit 1, Qty 1, FUSEHOLDER-EXTR POST 15A 250 V UL, 04703, 342014. Delete entries XF1MP1, XF1MP2, XF1MP3, and XF1MP4. Add as part of XQ1, HP Part Number 2950-0038, Check Digit 1, Qty 1, NUT-SPCLY 1/2-24-THD .125-IN-THK, 04703, 903-12. Page 24, Figure 11: Change Index Number 6 to HP Part Number 08447-00002, Check Digit 3, PANEL REAR, Qty 1. Page 28, Figure 15: At S1 LINE switch, delete switch connection between wire numbers 98 and 94. Change wire number 94 to wire number 90 and draw a jumper between wire numbers 98 and 90. CHANGE D Pages 21 through 23, Tables 4 through 6: Change A1CR9 to HP Part Number 1884-0012, Check Digit 9, Qty 1, THYRISTER: SCR 2N358 TO-8 VRRM=200, 01921, 2N 3528. | Delete A1R14, HP Part Number 0757-0401, Check Digit 0, Qty 1, R:FXD MET FLM 100 OHM 1% 1/8W. Page 28, Figure 15: Delete resistor R14 and its connection to ground. HEWLETT Гу PACKARD HEWLETT-PACKARD SALES AND SERVICE OFFICES To obtain servicing information or to order replacement parts, contact the nearest Hewlett- Packard Sales and Service Office listed in the HP Catalog, or contact the nearest regional office listed below: IN THE UNITED STATES CALIFORNIA 3939 Lankershim Boulevard North Hollywood 91604 GEORGIA P.O. Box 105005 2000 South Park Place Atlanta 30339 ILLINOIS 5201 Tollview Drive Rolling Meadows 60008 NEW JERSEY W. 120 Century Road Paramus 07652 IN CANADA Hewlett-Packard (Canada) Ltd. 17500 South Service Road Trans-Canada Highway Kirkland, Quebec H9J 2M5 IN FRANCE Hewlett-Packard France F-91947 Les Ulis Cedex Orsay IN GERMAN FEDERAL REPUBLIC Hewlett-Packard GmbH Vertriebszentrale Frankfurt Berner Strasse 117 Postfach 560 140 D-6000 Frankfurt 56 IN GREAT BRITAIN Hewlett-Packard Ltd. King Street Lane Winnersh, Wokingham Berkshire RG11 SAR IN OTHER EUROPEAN COUNTRIES SWITZERLAND Hewlett-Packard (Schweiz) AG 29 Chemin Chateau Bloc CH-1219 LeLignon-Geneva IN ALL OTHER LOCATIONS Hewlett-Packard Inter-Americas 3200 Hillview Avenue Palo Alto, California 94304 MANUAL CHANGES MANUAL IDENTIFICATION Model Number: 8447D/E/F Date Printed: SEPT. 1980 Part Number: 08447-90033 This supplement contains important information for correcting manual errors and for adapting the manual to instruments containing improvements made after the printing of the manual. To use this supplement: Make all ERRATA corrections Make all appropriate serial number related changes indicated in the tables below. — Serial Prefix or Number _ Make Manual Changes _. —— Serial Prefix or Number Make Manual Changes D> NEW ITEM NOTE Manual change supplements are revised as often as necessary to keep manuals as current and accurate as possible. Hewlett-Packard recommends that you periodically request the latest edition of this supplement. Free copies are available from all HP offices. When requesting copies quote the manual identification information from your supplement, or the model number and print date from the title page of the manual. 10 DECEMBER 1981 HEWLETT sre U PACKARD Printed in U.S.A. ERRATA Page 21, Table 4: Change A1CR1-4 to HP Part Number 1901-0743, Check Digit 1, DIODE:PWR RECT IN4OOU 4OOVIA DO-41. Change U1 and U2 (for Standard and Options 010 and 011) to HP Part Number 5086-7005, Check Digit 6. Page 22, Table 5: Change A1CR1-4 to HP Part Number 1901-0743, Check Digit 1, DIODE:PWR RECT IN4004 4OOVIA DO-41. Change U1 to HP Part Number 5086-7006, Check Digit 7. Page 23, Table 4: Change A1CR1-4 to HP Part Number 1901-0743, Check Digit 1, DIODE:PWR RECT IN4004 4OOVIA DO-41. Change U1 to HP Part Number 5086-7006, Check Digit 7. Change U2 to HP Part Number 5086-7005, Check Digit 6. Page 24, Figure 11: Delete HP Part Numbers 08447-00017, 08447-00018, 08447-00019, 08447-00021, 08447— 00022, 08447-00023, 08447-00024, 08447-00025, 08447-00040, 08447-00041, 08447- 00042, 08447-00043, 08447-00044, 08447-00045, 08447-00046, апа 08447-00047 from Index Number 10. D» Add to Index Number 10: HP HP Part Part Part Part Part Part Part Part Number Number Number Number Number Number Number Number 08447-00058, 08447-00059, 08447-00060, 08447-00061, 08447-00062, 08447-60063, 08447-00064, 08447-00065, Check Check Check Check Check Check Check Check Digit 9, Digit O, Digit 3, Digit 4, Digit 5, Digit 6, Digit 7, Digit 8, PANEL: PANEL: PANEL: PANEL: PANEL: PANEL: PANEL: PANEL: FRONT FRONT FRONT FRONT FRONT FRONT FRONT FRONT (8447D STANDARD). (8447D OPTION 001). (8447D OPTION 010). (8447D OPTION 011). (8447E STANDARD). (8447E OPTION 010). (8447F STANDARD) . (8447F OPTION 010). KP} packann HP Part No. 08447-90033 Printed in U.S.A. ">
Advertisement
Key features
- Provides 26 dB of gain
- Thin film amplifier is hermetically sealed
- Low noise, low distortion, flat frequency response
- Long term stability and reliability
- Wideband, 0.1–1300 MHz
- Input and output impedance: 50 ohms
- Voltage gain flatness: ±0.5 dB
- Power requirement: 100/115/220/230 VAC, 50/60 Hz
Frequently asked questions
The HP 8447D provides 26 dB of gain.
The HP 8447D has a frequency range of 0.1–1300 MHz.
The HP 8447D has an input and output impedance of 50 ohms.
The HP 8447D has a voltage gain flatness of ±0.5 dB.
The HP 8447D requires 100/115/220/230 VAC, 50/60 Hz of power.