HP 4957A User's Manual

HP 4957A User's Manual
Data Communications Test Library
HP 4957A Protocol Analyzer
Г HEWLETT
PACKARD
HP Part No. 04957-99001 |
Microfiche Part No. 04957-98802
Printed in U.S.A. July 1991
First Edition
EC791
Notice
Hewlett-Packard makes no warranty of any kind with regard to this material
including, but not limited to, the implied warranties of merchantability and
fitness for a particular purpose. Hewlett-Packard shall not be liable for errors
contained herein or for incidental or consequential damages in connection
with the furnishing, performance, or use of this material.
Hewlett-Packard assumes no responsibility for the use or reliability of its
software on equipment that is not furnished by Hewlett-Packard.
This document contains proprietary information which is protected by
copyright. No part of this document may be photocopied, reproduced,
or transiated to another language without the prior written consent of
Hewlett-Packard Company. The information contained in this document is
subject to change without notice.
If your software application or hardware should fail, contact your local
Hewlett-Packard Sales Office listed in the protocol analyzer operating manual,
© Copyright 1991 Hewlett-Packard Company
Colorado Telecommunications Division
5070 Centennial Boulevard ВЕ
Colorado Springs, Colorado 80913-2497
me
reia
1 !
Lamentos!
Notice
This application can be used with both the HP 4957A Protocol Analyzer
and the HP 4952A Protocol Analyzer. The User's Guide refers to the HP
4952A in the operating procedures but operation is the same on the HP
4957A.
Е
LE
3 | tera
LR
Contents
Product Introduction
-
Looking Up à PrOZram.………useeerseresrsensesneses prorvaneeconereeoneneneerocenorenrereercereeocecacene 1-1
|
Using a Program........e... enero. reteset t ether ra ssc res satan ese R esas rere seen atta aren 1-2
) |
Program Lisf ...e. e... enonenoracacanenoneooorernrcueaocoroanocrooeoanreneacoceoeoccracro roo 1-3
Installing Programs
Loading a Program from Disc. peanroreresecanereorevensecarcoracacrncuraerencorearooreorrereccenetecaa 2-1
Copying the Master DisC......... unoenerocenaacecenaneoorccncuces pnboaotenocacaanreoneereaoa enana ien e enecere. 2-2
Creating Your Customized Test LIDrary. cineca, re 22
Printing a Program............. me... peiroconDareeonecanencerren ore ana rececconceaoore cero tcacrre renos 2-3
Program Descriptions
Contents - 3
устр
тие
Printing History
OO NS ТОННА ННИЕ:
New editions are complete revisions of the manual. Update packages are issued between
editions. They contain additional and replacement pages to be merged into the manual by the
customer. The dates on the title page change only when a new edition or a new update 1s
published. No information is incorporated into a reprinting unless it appears as a prior
update. The edition does not change when an update is incorporated.
Many product updates and fixes do not require manual changes and, conversely, manual
corrections may be done without accompanying product changes. Therefore, do not expect a
one-to-one correlation between product updates and manual updates.
Edition 1 sacseaseses .. July 1989
Problems? Call for Help
If you have problems operating your HP protocol analyzer or any of the applications, call the
CTD Customer HelpLine or use your fax machine to send your questions.
HelpLine - (719) 531-4567 ñ
Fax - (719) 531-4505 ||
ант
en
Printing History - 4
Product Introduction
This package of tests is intended to help you easily apply the power of Hewlett-Packard's
protocol analyzers in the solution of common data communication problems. They also
provide examples and starting points for you to develop custom tests. The Data
Communications Test Library programs are written entirely in HP 4951C Monitor or Simulate
menus. They work with the HP 4951C and HP 4952A in Asynchronous, Synchronous,
SDLC/HDLC, X.25, and other environments.
This section presents a list of the programs with brief descriptions, grouped by application. A
more detailed description of each program, with instructions for use and program results, is in
the final section (Section 3) of this manual. It is highly recommended that a copy of the
master disc be made. Instructions for copying the master disc, as well as loading, storing,
modifying, and printing programs are in Section 2.
Looking up a Program
Al programs in this collection use the file name format defined below to aid in locating a
desired program on a disc. The first letter of the file name indicates the program application
listed in the following table.
General purpose asynchronous monitor programs
General purpose asynchronous simulate programs
Async terminal tests
Async printer tests
Test devices sending to async printers
Test async devices across a modem link
Interface tests (level 1)
SDLC tests
Instrument setups
X.25 tests
‚Сон тон»
Product Introduction 1-1
All tests are stored on disc with a comment field that briefly describes the test.
Using a Program
If you are not yet familiar with your HP protocol analyzer, instructions for loading programs
are presented in the next section. Hewlett-Packard recommends that you make a working
copy of your master disc, also covered in Section 2, and then store the master disc in a safe
place. Because all programs in the Data Communications Test Library are standard menus,
they can be infinitely copied and easily modified for your particular needs. Note that any
"Load Menus" or "Store Menus" operation involves Monitor, Simulate, Setup, and Run Menus.
Data Communications Configuration (Protocol Analyzer Setup)
For consistency and simplicity, all programs in this library arc stored with a common set of
data communication parameters that are loaded into the analyzer when you load the program
These parameters may be easily changed in the Setup Menu to suit your system. Refer to the
Operating Manual for your Hewlett-Packard protocol analyzer for guidance.
Note Changing some parameters, such as Code, Mode, or Character Framing, ma
require corresponding changes to the Monitor or Simulate menus. Programs
modified to take advantage of unique HP 4952A program features may not
run on the HP 4951C.
The parameters loaded with all library programs (except interface tests) are as follows:
9600 bps line speed
ASCII-7, Odd parity for async
EBCDIC, DCE supplies DTE clock for SDLC
ASCII-8, DCE supplies DTE clock for X.25/HDLC
The parameters loaded for interface tests are as follows:
2400 bps line speed
ASCII-8, no parity
1.2 Product Introduction
TA
winnie,
Data Communications Test Library
Program List
Program Name Program Purpose
General purpose async monitor
A COUNTCHR Count DTE and DCE characters for 1 min
A_COUNTPAR Count DTE and DCE parity errors for 1 min
General purpose async simulate
B_ASC7EVER Send ASCH7 even parity errored string
B_ASC7ODER Send ASCH7 odd parity errored string
B_AUTOBAUD Find terminal’s or printer’s bit rate
B BRBRPOLE Send 81 char with Xon/off and DTR -continuous
B BRBRPOLS Send 81 char with Xon/off and DTR - 4 pages
B_FOXFLOW Send OBFox with Xon/off and DTR - continuous
Async terminal tests
C ALGNMNT Send "cross-hair in square” pattern for alignment
C RESPTIME Measure avg & instant response time CR - prompt
Async printer tests
D BUFFER Determine printer’s buffer characteristics
D DTR Exercise printer with DTR flow control
D _XONXOFF Exercise printer with Xon-Xoff flow control
Test devices sending to async printers
E DTRFLOW Exercise device sending to printer - DTR
Exercise device sending to printer - Xon/off
Product introduction 1-3
F BRBRPOLS
F BUFFER
I AVRTSCTS
I AVTURND
I CDOFF
I CD_TO RD
I CD TO TD
I CTSTD
1 CTS ERR
I DSR_DTR
I LCLTURND
I RMT _TRND
I RTS_CTS
[ RTS ERR
[ RTS TD
S CNTERRS
S_CNTIVALL
S_CTSTPRDC
S CTSTPRDT
S HILITFLG
S SNRM
S UTIL
U_BURS SPS
U BUR A PS
U_IPARS
U-SYALL7
U SYALLS
U UNISCOPE
1-4 Product Introduction
Test async devices across a modem link
Send 4 pages 81 char with Xon/off & CTS modem link
Determine printer’s buffer character modem link
Interface tests
Measure average RTS-CTS time - 10 intervals
Average remote turn-around time -RTS-CD
Check for CD off while receiving data
CD on to received data time
CD off to transmitted data time
CTS on to transmitted data time
Check for CTS off before RTS off
Detect transitions and glitches on DSR & DTR
Local turn-around time CD off to RTS on
RTS off to CD on time
RTS on to CTS on time
RTS off while transmitting data
RTS on to transmit data
SDL tests
Count DTE & DCE aborts & FCS errors - 60 min
Count DTE and DCE I-frames and all non I-frames -60 min
Count DCE XIDs, SNRMs / DTE XIDs, UAs - 60 min
Count DTE XIDs, SNRMs / DCE XIDs, UAs - 60 min
Highlight flags on line
Set leads on, send SNRM, beep on other than UA
Measure half duplex BOP line utilization -10 min
Instrument setups
Setup for sync Burroughs poil select
Setup for async Burroughs poll select
Setup for common IPARS system
Setup to capture all bits on 7 bit sync link
Setup to capture all bits on 8 bit sync link
Setup for Uniscope sync link
pee
i
enon
X CALLTRYS
X CNTALLFR
X CNTCALLS
X CNTCONCT
X CNTDCEFR
X CNTDCFRT
X CNTDTEFR
X CNTDTFRT
X CNTERRS
X CNTIVALL
X DCEUTIL
X DTEUTIL
X HILITFLG
X LINKUPDN
X LVLI
X.25 tests
Count link attempts and irregular response
Count DTE + DCE SABM, UA, DISC, FRMR, RNR
Count DTE & DCE CAlLLs & CALL ACCEPTs -1 hr
Count DTE and DCE SABMs and UAs -60 min
Count DCE SABM, UA, DISC, FRMR, RNR
Count DCE SABM, UA, DISC, FRMR, - 60 min
Count DTE SABM, UA, DISC, FRMR, RNR
Count DTE SABM, UA, DISC, FRMR - 60 min
Count DCE and DTE aborts and FCS errors - 60 min
Count DCE and DTE-I frames vs total frames - 10 min
DCE utilization - 10 min
— DTE utilization - 10 min
Highlight flags
Bring link up, then down, highlight errors
Detect control lead and interface problems
Product Introduction 1-5
mm yo Berman
Installing Programs
Instructions for loading programs are presented in this section. Also covered are directions
for copying the master disc, creating a customized test library, and instructions for printing
programs,
Loading a Program from Disc
I.
Insert the Data Communications Test Library or your customized test library disc
(described on the next page) into the disc drive. |
Press [MORE], then <Mass Store > to display the disc directory.
Use the arrow keys to select and highlight the program of your choice. A description
of each test is included in the next section.
Press <Load>, then <Execute>. The program you chose is loaded. Press [Exit] to
return to the top level, Press <Setup> to check or modify datacom link parameters.
you loaded a Monitor Program, press <Mon Menu> to view or modify it. If you
loaded a Simulate Program, press <Sim Menu> to view or modify it.
To execute the program at the top menu level, press <Run Menu>, then < Monitor >
or <Simulate >, depending on which type of test you loaded.
Installing Programs 2-1
Copying the Master Disc
The master disc contains the Data Communications Test Library of programs. You must use
the basic loading and storing features of the protocol analyzer to copy the programs to a work
disc. If you have access to an HP 4952A Protocol Analyzer, and wish to copy the entire disc,
you may use the "Copy Disc" utility supplied with the 4952A.
Hewlett-Packard recommends that you copy the programs that you will use from the master
disc to a work disc. This disc will be called your "customized test library". New discs must be
formatted before you can store on them.
Creating Your Customized Test Library
1. Insert your master disc (containing the sample programs) into the disc drive.
2. At the top level menu, press [MORE] and < Mass Store>. The disc is read and the
directory of files on the disc is displayed.
3. Use the arrow keys to locate and highlight the first program you wish to load.
Note The order in which you load the programs from the master disc to your
customized test library disc will be the order in which they will appear on the
disc,
4. Press <Load> and <Execute>. The program is now in memory in the protocol
analyzer. Datacom link parameters should be checked in the <Setup> menu and
modified as needed.
5, If you wish to view or modify the program, follow steps a-d below; otherwise, go
directly to step 6.
a. Press [Exit].
b. Press <Mon Menu> or <Sim Menu> (depending on which type of program you
have loaded). Make any changes required to the program for your particular
application.
2-2 Installing Programs
c. Press [Exit].
d. From the top level menu, press [More], then < Mass Store>.
Note Changing some parameters, such as Code, Mode, or Character Framing, may
require corresponding changes to the monitor or simulate menus. Programs
modified to take advantage of unique HP 4952A features may not run on the
HP 4951C.
6. Press <Store>, Move the cursor to the File Name line and enter the name you wish
to call this program. You may use the given default name if vou wish. Be sure the
File Type is "Menus".
7. Remove the master disc and insert your customized test library disc into the disc
drive.
8. Press <Execute>, When the disc activity stops, the Mass Store menu will return.
Repeat steps 1 through 8 above until you have loaded all the programs you will need on your
customized test library disc,
Printing a Program
You may print program listings to help modify or understand a program. Do the following to
output a monitor (simulate) program listing to a printer.
Print setup - HP4951C
1. Load the Print Application Program.
a. From the top level menu, press [MORE], then <Mass Store >.
b. Press [MORE], then <Print Appl>, then <Execute>.
installing Programs 2-3
qe
2. Configure the Print Application Program.
a. From the top level menu, press [MORE], then <Print>.
b. Define the printer parameters, но
Printing a Monitor (Simulate) Program - HP 4951C. —
1. From the top level menu, press [MORE], then <Print>.
2. Select <Monitor> (<Simulate >), press <Execute>. Г
Print setup - HP 4952A
1. From the top level menu, press [MORE], then <Remote & Print>.
2. Press <Print Setup> and define the printer parameters. 1
3. Press the <Save Cnfg> key to save your printer configuration.
4. Press [EXIT] twice to return to the main level menu.
Printing a Monitor (Simulate) Program - HP 4952A
1. Load the program into the protocol analyzer. 22325
2. Press the <Mon Menu> (<Sim Menu>) key.
3. Press [MORE] three times, then <Print Prog> to print the program to the printer.
2-4 Installing Programs
Program Descriptions
All programs in this collection use the file name format defined here to aid in locating a
desired program on a disc. The first letter of the file name indicates the program application
listed in the following table.
General purpose asynchronous monitor programs
General purpose asynchronous simulate programs
Async terminal tests
Async printer tests
Test devices sending to async printers
Test async devices across a modem link
Interface tests (level 1)
SDLC tests
Instrument setups
X.25 tests
Note Program names appear in the upper right hand corner on the following
program description pages.
Program Descriptions 3-1
REVISION: (06-25-87) PROGRAM NAME: A COUNTCHAR
PROGRAM PURPOSE: Count DCE and DTE characters for 1 minute (or 10 minutes).
Useful for checking link throughput, file sizes, etc.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, parity, etc.
2. "Don’t Care" characters in Block 2 may be replaced by any desired character string. Fo
3. "Stop Tests" in Block 9 may be removed for 10 minute operation, with minutes | à
counted in counter 1,
4, The first counter 1 test value in Block 9 may be replaced by any desired (minutes - 1) -
value for different test duration.
Note that high line utilization above 9600 bps may cause the analyzer’s buffer to overflow,
returning the instrument to top level. |
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE characters x 1
Counter 3: DTE characters / 1000
Counter 4: DCE characters x 1 |
Counter 5: DCE characters / 1000
Timer 1: Milliseconds of test
(Counter 3 x 1000) + Counter 2 a
DTE chars/sec = `
(Counter 1x60) + Timer 1/1000
(Counter 5 x 1000) + Counter 4
(Counter 1 x 60) + Timer 1/1000 pes
DCE chars/sec =
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-2 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: A COUNTPAR
PROGRAM PURPOSE: Count DCE and DTE parity errors for 60 seconds (or ten minutes).
Parity errors indicate a link problem.
OPERATING INSTRUCTIONS: Run Monitor {Line or Buffer)
1. Check Setup Menu for proper bit rate, parity, etc.
2. “Stop Tests" in Block 9 may be removed for 10 minute operation, with minutes
counted in counter 1.
3. The first counter À test value in Block 9 may be replaced by any desired (minutes - 1)
value for other test durations.
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE parity errors x 1
Counter 3: DTE parity errors / 1000
Counter 4: DCE parity errors x 1
Counter 5: DCE parity errors / 1000
Timer 1: Milliseconds of test
(Counter 3 x 1000) + Counter 2
(Counter 1x60) + Timer 1/1000
DTE parity errors/sec =
(Counter 5 x 1000) + Counter 4
DCE parity errors/sec = :
(Counter 1 x60) + Timer 1/1000
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-3
REVISION: (06-25-87) PROGRAM NAME: B ASC7TEVER
PROGRAM PURPOSE: Continuously send ASCII 7 even parity string in which all "R"s have
errored parity. Useful for testing device response to parity errors.
OPERATING INSTRUCTIONS: Run simulate
1. Check Setup Menu for proper bit rate.
2 Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
All transmitted "R"s have parity errors.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3.4 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: B_ASC7ODER
PROGRAM PURPOSE: Continuously send ASCII 7 odd parity string in which all "R"s have
errored parity. Useful for testing device response to parity errors.
OPERATING INSTRUCTIONS: Run Simulate
1, Check Setup Menu for proper bit rate.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
All transmitted "R"s have parity errors.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-5
REVISION: (06-25-87) PROGRAM NAME: B AUTOBAUD
PROGRAM PURPOSE: Send string so that terminal or printer’s configured bit rate will
appear on tested device. Useful for determining async device speed. Identifies 1200, 2400,
9600, 19200 devices.
OPERATING INSTRUCTIONS: Run simulate
Test sends as DCE; may be changed in Simulate Menu to DTE,
RESULTS:
Bit rate of tested device will appear on device.
Note that this test was written for 8 bit ASCII and may not work with 7 bit ASCII data codes.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-6 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: B_BRBRPOLE
PROGRAM PURPOSE: Continuously send 81-character string with both Xon/Xoff and
DTR flow control. Useful for exercising terminals, printers, and other devices. Lost or
errored characters are easily detected visually.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
Note that this program sends no carriage-return/line feed and assumes that continuous
character strings will be automatically "wrapped" at the end of each line by the device under
test.
RESULTS:
81-character "stair-step” pattern appears on printer or terminal. This pattern is very visually
distinctive; errored or lost characters may be detected visually.
Unlisted Counters and Timers may be used in the program, but their contents have no
meaning.
Program Descriptions 3-7
REVISION: (06-25-87) PROGRAM NAME: B_BRBRPOLS
PROGRAM PURPOSE: Send approximately 4 pages of an 81-character string with both
Xon/Xoff and DTR flow control. Useful for exercising terminais, printers and other devices,
Lost or errored characters are easily detected visually,
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.,
Note that this program sends no carriage-return/line feed and assumes that continuous
character strings will be automatically "wrapped" at the end of each line by the device under
test.
RESULTS:
81-character "stair-step” pattern appears on printer or terminal. This pattern is very visually
distinctive; errored or lost characters may be detected visually.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-8 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: B FOXFLOW
PROGRAM PURPOSE: Send QUICK BROWN FOX message with Xon/Xoff and DTR
flow control continuously. Useful for exercising terminals, printers, and other devices. Lost or
errored characters are easily detected visually.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
QUICK BROWN FOX message sent to terminal or printer. This pattern is very visually
distinctive; errored or lost characters may be visually detected.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions. 3-9
REVISION: (06-25-87) PROGRAM NAME: C ALGNMNT
PROGRAM PURPOSE: Send "cross-hair in square” pattern for terminal display alignment.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
"Cross-hair in square” pattern on terminal display.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-10 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: C RESPTIME
PROGRAM PURPOSE: Measure average and instantaneous response time from DTE
carriage-return to DCE prompt. Response time is a key indicator of system loading problems
or link errors, and is a major contribution to user dissatisfaction.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test assumes terminal is DTE, host is DCE, carriage-return from terminal gets
carriage-return or line-feed, then any prompt character from host.
3. Press Return on terminal as many times as desired.
RESULTS:
Counter 1: Number of responses
Counter 2: Minutes total resp time
Timer 1: Last response time
Timer 2: mSec total response time
(Counter 2 x 60 + Timer 2/1000)
Average response time per/sec =
Counter 1
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3- 11
REVISION: (06-25-87) PROGRAM NAME: D BUFFER
PROGRAM PURPOSE: Determine printer buffer characteristics,
PROGRAM DESCRIPTION: Send Xs until Xoff or DTR off, then 60-character string to
visually determine printer buffer after Xoff or DTR off. Incompatibilities between the printer
buffer and the sending device flow control response may cause lost characters on printouts,
OPERATING INSTRUCTIONS: Run Simulate
1, Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
Note that this program sends no carriage-return/line feed and assumes that continuous
character strings will be automatically "wrapped" at the end of each line by the device under
test.
RESULTS:
Counter 1: Characters before first flow off
Counter 2: Characters between flow on/off
Counter 3: Number of flow off /on cycles
Printer will print X until it sends a flow off (Xoff or DTR off), then
"123456789A123456789B123456789C123456789D 123456789 E 123456789" is sent to the printer.
The number of characters of this string that are printed indicates the printer’s buffer size after
flow off.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-12 Program Descriptions
pee
REVISION: (06-25-87) PROGRAM NAME: D DTR
PROGRAM PURPOSE: Exercise a printer with DTR flow control. Program sends 78-
character lines of X with carriage return/line feed at the end of each line. See also General
purpose async simulate programs.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
Continuous display of 78-character lines of X.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-13
REVISION: (06-25-87) PROGRAM NAME: D XONXOFF
PROGRAM PURPOSE: Exercise a printer with Xon/Xoff flow control. Program sends 78-
character lines of X with carriage return /line feed at end of each line. See also General
purpose async simulate programs.
OPERATING INSTRUCT IONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DCE; may be changed in Simulate Menu to DTE.
RESULTS:
Continuous display of 78-character lines of X.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-14 Program Descriptions
pes
REVISION: (06-25-87) PROGRAM NAME: E DTRFLOW
PROGRAM PURPOSE: Test devices sending to printers with DTR control. Determine how
many characters device sends after DTR off. Incompatibilities between the printer buffer and
the sending device flow control response may cause lost characters on printouts.
OPERATING INSTRUCTIONS: Run Simulate
1, Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DTE; may be changed in Simulate Menu to DCE.
3. Send large file from host as if printing.
RESULTS:
Counter 2: Number of DTR cycles
Counter 3: Total chars sent with/DTR off
Counter 3
Average characters sent with DTR off = eee.
Counter 2
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-15
REVISION: (06-25-87) PROGRAM NAME: E_ XONXOFF
PROGRAM PURPOSE: Test devices sending to printers with XON/XOFF control. Find
how many characters device sends after Xoff. Incompatbilities between the printer buffer and
the sending device flow control response may cause lost characters on printouts.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, parity, etc.
2. Test sends as DTE; may be changed in Simulate Menu to DCE.
3. Send large file from host as if printing.
RESULTS:
Counter 2: Number of Xon/Xoff cycles.
Counter 3: Total characters sent after Xoff.
Counter 3
Average characters sent after Xoff = — eme
Counter 2
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning. |
3-16 Program Descriptions
REVISION: (06-23-87) PROGRAM NAME: F_BRBRPOLS
PROGRAM PURPOSE: Send 81-character string with both Xon/off and CTS flow control,
(approximately 4 pages). This is useful for testing printers or other devices across modem
links. Lost or errored characters are easily detected visually,
OPERATING INSTRUCTIONS: Run Simulate
Check Setup Menu for proper bit rate, parity, etc.
Test sends as DTE. |
Test expects DSR, CD, and CTS to be high, but beeps if low.
Terminal emulator may be used to dial link.
комн
Note that this program sends no carriage-return/line feed and assumes that continuous
character strings will be automatically "wrapped" at the end of each line by the device under
test.
RESULTS:
81-character “stair-step pattern appears on the printer or terminal at the other end of modem
link.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-17
REVISION: (06-25-87) PROGRAM NAME: F_BUFFER
PROGRAM PURPOSE: Determine printer buffer characteristics across the modem link.
Incompatibilities between the printer buffer and the sending device flow control response may
cause lost characters on printouts. |
PROGRAM DESCRIPTION: Send Xs until Xoff or CTS off, then 60-character string to
visually determine printer buffer after Xoff or CTS off.
OPERATING INSTRUCTIONS: Run Simulate
Check Setup Menu for proper bit rate, parity, etc.
Test sends as DTE; may be changed in Simulate Menu to DCE.
Test expects DSR, CD, and CTS high, but will beep if they are not.
Test raises DTR,RTS.
Link may be dialed using terminal emulator.
Woh Wb
Note that this program sends no carriage-return/line feed and assumes that continuous
character strings will be automatically "wrapped" at the end of each line by the device under
test.
RESULTS:
Counter 1: Characters before first flow off
Counter 2: Characters between flow on/off
Counter 3: Number of flow off/on cycles
Printer will print X until it sends a flow off (Xoff or DTR off) then
"123456 789A 123456 789B123456789C123456789D 123456 789E 123456789" is sent to the printer.
The number of characters of this string that are printed indicates the printer’s buffer size after
flow TSoff.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-18 Program Descriptions
REVISION: (06-25-87 PROGRAM NAME: I AVRTSCTS
PROGRAM PURPOSE: Measure average RTS to CTS time for 10 intervals. On half duplex
systems, RTS to CTS delay is one major factor in link efficiency. Longer time reduces
throughput, shorter time increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of RTD to CTS periods
Timer 1: Total RTS to CTS time
Average RTS to CTS time = =--m==——————.
Counter 1
Transitions are highlighted in the data and state display.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-19
REVISION: (06-25-87) PROGRAM NAME: I AYTURND
PROGRAM PURPOSE: Measure average remote turn-around time (RTS off to CD on) on
half duplex link for § turn-arounds. Link efficiency is highly affected by turn-around time.
Longer time decreases throughput, shorter time increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of turn-arounds
Timer 1: Total turn-around time
Average turn-around {ime = ========--=------
Counter 1
Transitions are highlighted in the data and state display.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-20 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: I CDOFF
PROGRAM PURPOSE: Check if CD is off while data is being received. In most systems,
CD should be on when receiving data.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of characters with Cd off
Characters received with CD off are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-21
REVISION: (06-25-87) PROGRAM NAME: 1 CD TO RD
PROGRAM PURPOSE: Measures time from CD on to received data on half duplex system.
Longer time delay reduces throughput, shorter time delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: CD on to received data time
Lead transition and first received character are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-22 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: I CD_TO TD
PROGRAM PURPOSE: Measure time from CD off to transmitted data on half duplex
system. longer time delay reduces throughput, shorter time delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: CD off to transmitted data time
Lead transition and first received character are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-23
REVISION: (06-25-87) PROGRAM NAME: I CTSTD
PROGRAM PURPOSE: Measure time from CTS on to transmitted data on half duplex
system. Longer time delay reduces throughput, shorter time delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: CTS on to transmitted data time
Lead transition and first received character are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-24 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: I CTS ERR
PROGRAM PURPOSE: Detect CTS drop before RTS to indicate link or modem problem.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of illegal transitions
Illegal lead transitions are highlighted.
‘Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-25
pee ie
REVISIÓN: (06-25-87) PROGRAM NAME: 1 DSR_DTR
PROGRAM PURPOSE: Detect transitions and glitches on DSR and DTR. In modem link,
these leads should generally stay on. Detect "on" to "off" transitions.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: DTR transitions
Counter 2: DSR transitions
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-26 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: I LCLTURND
PROGRAM PURPOSE: Measure local turn-around (Cd off to TRS on) on half duplex
system. Longer time delay reduces throughput, shorter time delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: Turn-around time
Lead transitions are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-27
REVISION: (06-25-87) PROGRAM NAME: I RMT TRND
PROGRAM PURPOSE: Measure time from RTS off to CD on in half duplex system and
number of polls before a response. Longer time dely reduces throughput, and shorter time
delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of polls
Timer 1: First RTS off to Cd on
Timer 2: Last poll RTS off to CD on
Lead transitions are highlighted.
If there is only one poll, time measurement is in Timer 1.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-28 Program Descriptions
bor
REVISION: (06-25-87) PROGRAM NAME: I RTS CTS
PROGRAM PURPOSE: Measure time from RTS on to CTS on in half duplex system and
number of polls before a response. Longer time dely reduces throughput, shorter time delay
increases error probability,
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: First RTS on to CTS on
Lead transitions are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-29
REVISION: (06-25-87) PROGRAM NAME: 1 RTS ERR
PROGRAM PURPOSE: Detect RTS off while transmitting data. RTS off while DTE 15
transmitting indicates DTE problem.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Counter 1: Number of characters with RTS off
Characters with RTS off are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-30 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: ! RTS TD
PROGRAM PURPOSE: Measure time from RTS on to transmitted data. Longer time delay
reduces throughput, shorter time delay increases error probability.
OPERATING INSTRUCTIONS: Run Monitor
1. Check Setup Menu for proper bit rate, parity, etc.
RESULTS:
Timer 1: Time from RTS on to transmitted data
Lead transitions and characters are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3 - 31
REVISION (06-25-87) PROGRAM NAME: S_CNTERRS
PROGRAM PURPOSE: Count DCE and DTE aborts and FCS errors for 60 minutes,
Aborts may indicate DTE problems, FCS error may indicate link problems.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE aborts
Counter 3: DCE aborts
Counter 4: DTE FCS errors
Counter 5: DCE FCS errors
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-32 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: S CNTIVALL
PROGRAM PURPOSE: Count DCE/DTE I frames- and all non I-frames for 60 minutes.
System throughput increases with the number of 1 frames per total frames.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE ali non I-frames
Counter 3: DTE I-frames
Counter 4: DCE all non I-frames
Counter 5: DCE I-frames
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning. |
Program Descriptions 3 - 33
REVISION: (06-25-87) PROGRAM NAME: § CTSTPRDC
PROGRAM PURPOSE: Count DCE XIDs SNRMs / DTE XIDs, UAs for 60 minutes. This
test assumes primary (host) is DCE.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1, Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DCE XIDs
Counter 3: DTE XIDs
Counter 4: DCE SNRMs
Counter 5: DTE UAs
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-34 Program Descriptions
REVISION: (66-25-87) PROGRAM NAME: § CTSTPRDT
PROGRAM PURPOSE: Count DTE XIDs SNRMs / DCE XIDs, UAs for 60 minutes. This
test assumes primary (host) 1s DTE.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE XIDs
Counter 3; DCE XIDs
Counter 4: DTE SNRMs
Counter 5: DCE UAs
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-35
REVISION: (06-25.87) PROGRAM NAME: § HILITFLG
PROGRAM PURPOSE: Highlight and capture /display only flags on line. Absence of flags
indicates inactive device.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
RESULTS:
Flags (hex 7E) are highlighted in buffer,
Only flags are captured or displayed.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-36 Program Descriptions
re о
REVISION: (06-25-87) PROGRAM NAME: S_SNRM
PROGRAM PURPOSE: Set leads on, send SNRM, beep on receipt of other than UA,
indicating error on part of secondary. This test assumes primary (host) as DCE.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Timeout of 3000 ms may be changed in Timer 1 test in Block 1.
RESULTS:
Beep on timeout (3000 ms) or response other than UA.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-37
REVISION: (06-25-87) PROGRAM NAME: §_ UTIL
PROGRAM PURPOSE: Measure half duplex bit oriented protocol line utilization for 10
minutes.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration maybe changed from 10 minutes by changing the statement in Block 3,
"If Counter 1 >9.
RESULTS:
Counter 1: Minutes of test
Counter 2: Minutes used by DTEs
Counter 3: Minutes use by DCE
Timer 1: mSec of test
Timer 2: mSec used by DTE
Timer 3: mSec used by DCE
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-38 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: U BURS SPS
PROGRAM PURPOSE: Setup for synchronous Burroughs poll/select link.
REVISION: (06-25-87) PROGRAM NAME: U BUR A PS
PROGRAM PURPOSE: Setup for asynchronous Burroughs poll /select link,
REVISION: (06-25-87) PROGRAM NAME: U IPARS
PROGRAM PURPOSE: Setup for common IPARS system.
REVISION: (06-25-87) PROGRAM NAME: U SYALL7
PROGRAM PURPOSE: Setup to capture all bits on 7-bit framed synchronous link, Useful
for preliminary analysis of unknown or disfunctional protocol. To maximize buffer utilization,
Hewlett-Packard protocol analyzers do not store some data, Le. bits berween frames in bit-
oriented setups,
REVISION: (06-25-87) PROGRAM NAME: U_SYALLS
PROGRAM PURPOSE: Setup to capture all bits on 8-bit framed synchronous link. Useful
for preliminary analysis of unknown or disfunctional protocol. To maximize buffer utilization,
Hewlett-Packard protocol analyzers do not store some data, i.e. bits between frames in bit-
oriented setups.
REVISION: (06-25-87) PROGRAM NAME: U_UNISCOPE
PROGRAM PURPOSE: Setup for Uniscope synchronous link.
Program Descriptions 3-39
REVISION: (06-25-87) PROGRAM NAME: X-CALLTRYS
PROGRAM PURPOSE: Detect and count link attempts and irregular responses. Irregular
response to SABM includes non-UA and non-SABM frames from either side and timeouts.
Irregular responses are highlighted. Test duration is 60 minutes.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement mn Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE link attempts (SABMs)
Counter 3: Irregular response to DTE
Counter 4: DCE link attempts (SABMs)
Counter 5: Irregular response to DCE
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-40 Program Descriptions
ATT
Pue
te
Lera ee
REVISION: (06-25-87) PROGRAM NAME: X CNTALLFR
PROGRAM PURPOSE: Count DTE plus DCE total (SABMs, UAs, DISCs, FRMRs, and
RNRs). In general, all these numbers should be low,
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. This test must be stopped manually [HALT /EXIT].
RESULTS:
Counter 1: (DCE & DTE) total SABMs
Counter 2: (DCE & DTE) total UAs
Counter 3: (DCE & DTE) total DISCs
Counter 4: (DCE & DTE) total FRMRs
Counter 5: (DCE & DTE) total RNRs
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3 - 41
REVISION: (06-25-87) PROGRAM NAME: X CNTCALLS _
PROGRAM PURPOSE: Count DTE and DCE CALLS and CALL ACCEPTs for 60
minutes. Difference between number of CALLS and CALL ACCEPTs on either side
indicates unsuccessful CALLS. ma
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1 Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59",
RESULTS: a
Counter 1: Minutes of test
Counter 2: DTE CALLS
Counter 3: DCE CALL ACCEPTs
Counter 4: DCE CALLS
Counter 5: DTE CALL ACCEPTS
Timer 1: mSec of test
In general, on an X.25 link, the count in counter 2 should be close to the count in counter 3,
and the count in counter 4 should be close to the count in counter 5.
Unlisted Counters and Timers may be used in the program, but their contents have no user Ш
meaning. “
En
3-42 Program Descriptions | |
REVISION: (06-25-87) PROGRAM NAME: X CNTCONCT
PROGRAM PURPOSE: Count DTE and DCE SABMs and UAs for 60 minutes. Number of
SABMs and UAs should be close to each other, and low for each side.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE SABMs
Counter 3: DCE UAs
Counter 4: DCE SABMs
Counter 5: DTE UAs
Timer 1: mSec of test
In general, on an HDLC (X.25) link, the count in counter 2 should be close to the count in
counter3, and the count in counter 4 should be close to the count in counter 5.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-43
Fong
REVISION: (06-25-87) PROGRAM NAME: X CNTDCEFR
PROGRAM PURPOSE: Count DCE SABM, UA, DISC, FRMR, and RNR. In general, all
should be fairly low numbers.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer) |
1. Check Setup Menu for proper bit rate, clock sources, etc. ~~
2. This test must be stopped manually [HALT /EXIT]. Ш
RESULTS: a
Counter 1: DCE SABMs В
Counter 2: DCE UAs u
Counter 3: DCE DISCs | ни
Counter 4: DCE FRMRs Do
Counter 5: DCE RNRs i.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3 - 44 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: X CNTDCFRT
PROGRAM PURPOSE: Count DCE SABM, UA, DISC, FRMR for 60 minutes. In general
all should be fairly low numbers,
+
ÖPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
“If Counter 1. 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DCE SABMs
Counter 3: DCE UAs
Counter 4: DCE DISCs
Counter 5: DCE FRMRs
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-45
REVISIÓN: (06-25-87) PROGRAM NAME: X CNTDTEFR
PROGRAM PURPOSE: Count DTE SABM, UA, DISC, FRMR and RNR. In general, all
should be fairly low numbers.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Thistest must be stopped manually [HALT/EXIT].
RESULTS:
Counter 1: DTE SABMs
Counter 2: DTE UAs
Counter 3: DTE DISCS
Counter 4: DTE FRMRs
Counter 5: DTE RNRs
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-46 Program Descriptions
me
REVISION: (06-25-87) PROGRAM NAME: X CNTDTFRT
PROGRAM PURPOSE: Count DTE SABM, UA, DISC, FRMR for 60 minutes. In general
all should be fairly low numbers,
3
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3
"If Counter 1 > 59".
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE SABMs
Counter 3: DTE UAs
Counter 4: DTE DISCs
Counter 5: DTE FRMRs
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-47
REVISION (06-25-87) PROGRAM NAME: X CNTERRS
PROGRAM PURPOSE: Count DCE and DTE aborts and FCS errors for 60 minutes.
Aborts may indicate DTE problems, FCS error may indicate link problems.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59",
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE aborts
Counter 3: DCE aborts
Counter 4: DTE FCS errors
Counter 5: DCE FCS errors
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-48 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: X CNTIVALL
PROGRAM PURPOSE: Count DCE/DTE I frames vs total frames. System throughput
increases with the number of I frames per total frames. Test duration is 60 minutes.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 60 minutes by changing the statement in Block 3,
"If Counter 1 > 59",
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE all frames
Counter 3: DTE I-frames
Counter 4: DCE all frames
Counter 5: DCE I-frames
Timer 1: mSec of test
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3 - 49
REVISION: (06-25-87) PROGRAM NAME: X DCEUTIL
PROGRAM PURPOSE: Measure full duplex DCE side bit-oriented protocol line utilization
for 10 minutes.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc,
2. Test duration may be changed from 10 minutes by changing the statement in Block 3,
"If Counter 1 > 9°.
RESULTS:
Counter 1: Minutes of test
Counter 2: DCE utilized minutes
Timer 1: mSec of test
Timer 2: mSec utilized DCE
Counter 2 x 60 + Timer 2 x 1000
Counter 1x 60 + Timer 1 x 1000
DCE utilization =
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-50 Program Descriptions
REVISION: (06-25-87) PROGRAM NAME: X DTEUTIL
PROGRAM PURPOSE: Measure full duplex DTE side Bit-Oriented Protocol line utilization
for 10 minutes.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Test duration may be changed from 10 minutes (D-1=9) in first counter limit of
Block 3.
RESULTS:
Counter 1: Minutes of test
Counter 2: DTE utilized minutes
Timer 1: mSec of test
Timer 2; mSec utilized DTE
Counter 2 x 60 + Timer 2 x 1000
DTE utilization = ---
Counter 1 x 60 + Timer 1 x 1000
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
Program Descriptions 3-51
REVISION: (06-25-87) PROGRAM NAME: X HILITFLG
PROGRAM PURPOSE: Highlight and capture/display only flags on line. Absence of flags
indicates inactive device.
OPERATING INSTRUCTIONS: Run Monitor (Line or Buffer)
1. Check Setup Menu for proper bit rate, clock sources, etc.
RESULTS:
Flags (hex 7E) are highlighted in buffer.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
3-52 Program Descriptions
FT
Млн
REVISION: (06-25-87) PROGRAM NAME: X LINKUPDN
PROGRAM PURPOSE: Bring link up, then down, "beep" and highlight errors.
OPERATING INSTRUCTIONS: Run Simulate
1. Check Setup Menu for proper bit rate, clock sources, etc.
2. Testis DTE.
RESULTS:
Leads not up, or improper response to SABM, are highlighted.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning.
Program Descriptions 3-53
REVISION: (06-25-87) PROGRAM NAME: X LVL]
pre
PROGRAM PURPOSE: Detect control lead and interface problems.
OPERATING INSTRUCTIONS:
1. Connect analyzer to X.25 link that should be active.
2. Run monitor program.
3. DTEclockis expected to be supplied by the DCE; it may be changed in the setup
menu.
RESULTS:
1. No beep indicates all needed leads are high, and presence of flags with clock on both
sides of the line,
2. If DSR, CD, or CTS is not high (DCE leads), counter 1 is set to 1 and the analyzer
beeps.
3. I DTR or RTS is not high (DTE leads), counter 1 is set to 2 and the analyzer beeps.
4, 1fno flags are present on the DCE side (pin 3), counter 2 1s set to 1 and the analyzer
beeps.
5. If no flags are present on the DTE side (pin 2), counter 2 1s set to 2 and the analyzer
beeps.
6. If flags are not present on either side, check for clocks on POD on pins 15 and 17, or
on pin 24 if DTE supplies its own clock.
Counter 1 or 2: value of 1 indicates a modem problem.
Counter 1 or 2: value of 2 indicates a terminal problem.
Unlisted Counters and Timers may be used in the program, but their contents have no user
meaning,
3-54 Program Descriptions
SALES OFFICES
Alphabetically by Country
HEADQUARTERS
OFFICES
if ng TEM sales office is
listed for your country or
area, please contact one of
these headquarters offices,
Asia Pacific
Hewlett-Packard Australia Lig.
31-41 Joseph Sireet
Blackburn, VIC 3138
Australia
Tet: (61/3) 272-2895
Fax: (61/3) 898-7831
Telex. 31024 MELBAA
Hewlett-Packard Asia Pacific Lid.
22/F Peregrina Tower, Lino
Centre
89 Queensway, Central
Hang Kong
Tel: (852) 849-7777
Fax: (852) 868-4997
Telex: 76793 HPA HX
Yokegawa Hewlett-Packard Ltd.
91-1, Takauracho, Hachioji-Shi
Tokyo 192 Japan
Tel: (81/4) 2648-0652
Fax: (81/4) 2648-8064
Canada
Mewiett-Packard (Canada) Ltd.
5150 Spectrum Way
Mississauga. Ontario Law 5G1
Те! (905) 206-4725
Fax: (905) 206-4739
Eastern Central Europe
Hewlett-Packard GmbH
Lieblgasse !
0 Box 72
1222 Vienna. Austria
Tel; (43/1) 2500-0
Fax {43/1) 2500-444
Telex: 134-425
Europe
Hewlett-Packard S.A.
Route du Nant d'Avril 150
CH-1217 Meyrin 2
Geneva, Switzerland .
Tel: (41) 22/780-81-11
Fax: (41) 22/780-85-42
Telex: 419019 hos
Latin America
Hewlett-Packard Co,
5200 Blue Lagoon Drive,
ath Figor
Miami, FL U.S.A, 33176
Tel: (305) 267-4245
Fax: (305) 267-4288
Middie East and Africa
Hewlett-Packard S.À.
international Sales Branch
Migdie East/Africa
Rue de Veyrot 36
РО Вох 364
1217 Меупп 1
Geneva, Switzerland
Tel: (41/22) 780-4111
Fax: (41/22) 780-4770
Telex: 418907
United Státes
1-800-452-4844
LOCAL AREA OFFICES
Arranged alphabetically by
country
Albania
IBS {Information & Business
Systems)
Hewlett-Packard Distributor
1, Ar. Kongres: Permetit
Tirana
Tel: 5/4223854
Fax: 5/42/3864
Aigeria
RTI.
Realisation Telematiques
internationales
Lot À Villa no, 57
Baba - Hassen
Wilaya de Tinaza
Algeris
Tel: (213) 2720-6430
Fax: 1213) 230-6431
Angola
Handled by HiFerformance,
South Africa
Argentina
Hewlett-Packard Argentina
Montaneses 2140/50
1428 Buenos Airas
Tel: (54/1) 781-4059/63
{54/1} 781-4090
Australia
An Asia Pacific
Headquarters Office
Mewiett-Packard Australia Lid.
31-41 Joseph Street
Blackburn, ViC 3120
Те! (61/3} 272-2895
Fax. {61/3) 898-7831
Telex: 31024 MELRAA
Adelaide
Hewlett-Packard Australia Lid.
191 Fyllarton Road
Dulwich, S.A 5065
Tel (61/81 366-5111
Fax (61/6) 332-5006
Canberra
Hewlett-Packard Australia Lid.
Thynne Street. Fern Mill Park
Bruce, ACT 2617
Те! (61/6) 251-6999
Fax (81/6) 251-6948
Telex: AA 62550
Melbourne
Hewlett-Packard Australia Ltd.
31-41 Joseptt Street
Blackburn, VIC 3130
Tel: (61/3) 272-2895
Fax: (61/3) 298-7831
Telex: 31024 MELBAA
Perth
Measurement innovation (WA!
Ply. Lid.
558 Duncraig Acad
PO Box 313)
Applecross, WA 6153
Tel: (61/9) 316-2757
Рах: {61/9} 316-1392
Мобне: 61-18-33-6434
Sydnsy
Hewlett-Packard Australia Lid,
17-23 Talavera Road
North Ryda, NSW. 2113
Fer (61/2) 950-7444
rax (61/2) 888-9072
Austria
Eastern Central Europe
Headquarters Office
Mewlett-Packard Сион
Liebigasse *
PO Box 72
1222 Vienna, Austria
Tei: (43/222) 2506-0
Fax: (43/222) 2500-444
Telex: 134-475
Bahrain
BAMTEC
Р.О. Sox 10373
Mezzanine Floor. Al-Hasan Bidg.
Diplomatic Area
Manama
Те! (973) 53-66-43
Fax: {9731 53-66-57
Telex: 8550 WAEL BN
Beigium
Hewlett-Packard Belgium
SAMY.
Bivd. de fa Woluwe 100/102
Woluwedal
8 1200 Brussels
Tet: (32/2) 7768-34-17
Fax: (32/2) 778-34-14
Bolivia
Siser, Lida
Pasaie Villegas 1213
Casilla 4084
La Paz
Tel {59-12} 34-0062
Fax: (549-12) 35-8268
Brazil
Edisa Hewiett-Packard S.A.
Alameda Rio Negro 750
Alpraville 06454-000
Barueri Sao Paulo
Tel: (55-11) 725-1444
Fax: (55-11) 725-1244
Telex: 11-71351
Edisa Hewlett-Packard S.A.
Rua Lauro Mueller 116 Grupo
805
222%0-150-Rio de Janeirg-R)
Tel: 155-21) 541-4404
Fax: 55-21) 295-7195
Telex: 21-21905
Brunei
Komputer Wisman Sdn Bhd
Кост 1. 3rd Moor
Jalan Tutong
85 Begawan
Brunei Darussalam
Tel 1673/2) 23918
Telex 0809-7437
Bulgaria
Tecnica Led.
Hewlett-Packard Distroutor
Studentsky Grad. Block 61-8
1100 Sofia
Tei 92/626117
Fax 92/629058
Canada
. Canada Headquartars Office
Hewlett-Packard (Canada) Eto.
5150 Spectrum Way
Mississauga. Ontario LáW 561
Tel: (905) 206-4725
Fax: (905) 206-4739
Alberta
Hewiet-Packard (Canada) Ltd.
150 6! Avenue SW.
Petro-Canada Tower. Suite 3600
Caigary, Alberta T2P 3Y7
Tet, (403) 262-0777
Fax: (403) 237-9309
Hewiert Packard (Canada) Ltd.
11120 178th Street
Edmanton, Alberta 155 182
Tel: (403) 486-6666
Fax: (403) 489-8764
British Columbia
Hewlett-Packard (Canada) Lid.
13575 Commerce Parkway
Suite 110
Crestwood Corporate Centre
Riehmand, British Columbia
VEV 2L1
Tel: 1604) 270-2277
Fax: (604) 270-0859
Manitoba
Hewlett-Packard {Canada} Lid.
200 Graham Avenue
10th Figor, Suite 1000
Winnipeg, Manitoba R3C 415
Tel: (204) 694-2777
Fax. (204) 694-3801
Nova Scotia
Hewlett-Packard (Canada) Ltd.
201 Browniow Avenue
Dartmouth, Nova Scotia
BIE TW2
Tel: (902) 468-4725
Fax: (902) 468-4311
Ontario
- Tlewiatt-Packard {Canada} Lid.
2670 Queensyiew Drive
Grtawa, Ontario K23-8K
. Tel (613) 320-6483
Fax: (613) 820-0377
Quebec
Hewieti-Packard { Canada) Ltd.
17500 Trans Canada Highway
South Service Road
Kirkland, Quebec HG) 2X5
Tel: 1514) 697-4237
Fax: (514) 697-6941
Saskatchewan
Hewlett-Packard (Canada) Ltd
2175 Airport Drive, #1
Saskatoon, Saskatchewan
S7L 7E1 ;
Tel: (306) 683-6550
Pax: (306) 664-3879
Chile
ASC Chile SA
Austria 2041
Santiago
Tel: (56-21 274-7676
Fax: (56-2) 223-1912
China, People's
Republic of
China Hewiett-Packard Co, Ltd.
5-6/F West Wing Office
China World Trade Center
№: 1 Jan Guo Men Wei Avenue
Beijing 100004
Ter: (86/1) 505-3888
Fax: (86/1) 508-2930
Telex: U85-22601 CTSHP CN
Cable: 1920 Seng
Chengdu
China Hewlett-Packard Co. Lid.
7/7 the Electronic Foreign Trade
Bidg.
#88 East 2nd Section,
Yi-Huan-Lu Road
Chengdu 615051, PRC
Tel, (86/28) 673-888
Fax: 186/29) 662-171
Guangzhou
China Hewlett-Packard Co., Ltd.
Room 1359, Office Tower
China Hotel, Lit Hua Acad
Guangzhou 510015
Tel: (86/20) 663-3886
Telex: 085-44888 CHLGZ CN
Shanghai
(hina Hewlett-Packard Co., Lil.
Room 638, Office Building
Shanghai Center
1376 Nan Jing Road West
Shanghai 200040
Ter (86/21) 278-8668
Fax: 186/21) 279-8677
Telex: 086-23577 CHPSB CN
Shenzhen
China Hewlett-Packard Co. Lid.
4/5 Huagiang Component
Building
Zhenhua Hgad, Shangbu District
Shenzhen City 518031
Tel 186/7535) 368-508
Fax (86/755) 363-154
Colombia
instrumentación, S.A.
Calle 115 No. 11410
Bogota
Tel: (571) 612-1313
Fax: (571) 612-0805
Commonwealth sf
independent States
(Russian Republic)
Hewtett-Packard Company
Pokrovski Blvd. 4/17 Kv 12
101000 Moscow
Ter: (007/095) 923-5001
Fax: (007/0958) 230-2611
Costa Rica
15. de Costa Hica
Calle 25, Avenida 6 & & No. 548
San Jose
Tel: (506) 33-3722
Fax: (506) 55-3528
Czech Republic
Hewlett-Packard Ceskosiovensko
500
Novodvorská 62
14200 Praha 4
Tel: 2/4717876
Fax: 247176111
Cyprus
Telerexa Lid.
Р.О. Вох 3152
Valentine House
8 Stassandrou St,
Nicosia
Tel: 13572} 445-628
Fax: (3572) 457-937
Telex: 5845 1Urx ey
Denmark
Hewlett-Packard A/S
Kongevejen 25
DK-3460 Birkersd
Tel: (45/45) 99-10-00
Fax: (45/45) 82-08-30
Hewiett-Packard A/S
Brenstrupgaardsves 13
8200 Aarhus N
Tel: 45) 8678-3000
Fax: 145) 8678-3033
Telex: 37406 hpas dk
SALES OFFICES
Alphabetically by Country {cont'd)
Dominican Republic
ESacomop. S.A.
Avenida John F Kennedy No. 11
Edificio Mercantit det Caribe
Santo Demingo
Ter (809) 541-3040
Pax: (809) 563-1259
Telex: ¡TT 346-0439
Ecuador
CYEDE Cia Lida.
Avenida Eloy Alfaro 1749
Quits
Tel (593-2) 44-4224
Fax: 1533-21 44-4223
Telex: 36322548 CYEDE ED
Egypt
ORASCOM
Inst Sawiris 4 Co
PO Box 1191
180. 26th July Street
Aguza/Cairs
Tel: (202) 302-69-30
Fax: 1202) 344-02-01
Telex: 92768 orsem un
El Salvador
PESA de El Salvador
25 Avenida Norte 1223
San Salvador
Tel: (503) 26-6858
Рах (503) 52-7772
Telex: 301 20539 IPESA SAL
Finland
Hewiett-Packard Oy
Puspankattiontie 17
42200 Espoo (Helsinki)
Tei {358/0) 887-21
ах. (358/0} 887-22-77
Hewlett-Packard Oy
Vaingnkaty 9G
40100 Jyväskylä
Tei 1358/41) 21-85-11
Fax (358/411 616-517
Hewlett-Packard Gy
Texnolegíantie 6
%0570 Quíu
Tel 1358/01) 5515144
Fax (358/01) 5515145
France
Aix-en-Provence
Hewlett-Packard France
¿AC de la Robole
21 Les Milles
Rue Pierre Duhem
13856 Aix-en-Provence Cédex
3
Tel {33) 42-37-28-00
Fax: (33) 42-37-28-50
Bardaaux
Hewlett-Packard France
Domame de Pátus
3. avente de Pythagore
33700 Merignac
Tel. {33} 42-37-28-00
Fax: {33} 42-37-28-50
Lyon
Hewlett-Packard France
Europart du Chêne
2. Rue Edison
69500 Bron
Tel (33) 72-15-17-00
Fax: (33) 72-15-18-05
Telex: 310-617
Orsay
Hewlett-Packard France
Zone Industrielle de Courtaboeu!
1, avenue du Canada
91947 Las Ulis Cédex
Tel: (33/1) 69-82-60-60
Fax: (33/1) 59-82-60-61
Telex: 600-048
Rennes
Hewlett-Packard France
4, Rue Louis Kerautret-Botme
35000 Rennes
Tel: (33) 99-32-56-00
Fax: (33) 99-32-56-58
Telex: 740-912
Ratan
Hewlett-Packard France
Parc de ta Vatine
3. Rue Jacques Monod
ВР 228
76136 Mont-Saint-Aignan
Cédex
Те! (33) 35-59-19-20
Fax: (33) 35-59-85-11
Telex: 770-035
Touigusa
Hewielt-Packard France
innonarc Yoie 7
BP 187
31676 Labège Cédex
Те! (33) 61-39-42-42
Рах: (33) 61-39-10-97
Telex: 531-639
Orleans
Hewlett-Packard France
Parc Tertiaire Héliopolis
Route de Micy
45380 La Chapetia Saist
Mesmin |
Те! (33) 38-43-94-56
Fax: (33) 38-88-2281
German Federal Republic
Headquarters
Hewlett-Packard GmbH
Herrenberger Strasse 130
7030 Bäblingen
Tel: (49) 7031/14-0
Fax: (49) 7031/14-1395
Hewlett-Packard GmbH
Bad Homburg
Hewlett-Packard Strasse
61352 Bad Homburg
Tel (49) 6172/16-0
Fax: (491 6172/16-1309
Bertin
Hewlett-Packard Graph
Lutzownlar 15
10785 Bertin
Tet: (49) 30/25452-0
Fax: (49) 30/25452-162
Biblingen
Hewiett-Packard GmbH
Schickardstrasse 2
/1034 Böblingen
Tei {493 7031/14-0)
Fax (49) 7031/14-6429
Bonn
Mewiett-Packard GmbH
Friegrica-Ebert-Allee 26
33113 Bonn
Tel (401 728/23400-1
Fax 149) 228/235-315
Dorimund
Hewlett-Packard GmbH
Schleefstrasse 28
44287 Dontmund-Aplerbeck
Tel (49) 23t/46001-0
Fax (49: 231/45001-27
Hamburg
Hewlett-Packard GmbH
Unerseering 16
22297 Hamburg 60
Tel. {49} 40/63808-5
Fax: 149) 40/63808-327
Hannover
Hewlett-Packard GmbH
Baumschulenalles 20-22
30625 Hannover 61
Tel (49) 511/0577.0
Fax: (49) 511/0577.176
Leipzig
Hewlett-Packard GmbH
Mikolaistrasse 13-23
04108 Leipzig
Tel: (49) 341/21635-0
Fax. (49) 341/21635-220
Mannheim
Hewlett-Packard GmbH
Mossiguer Weg 2-4
58309 Mannheim
Tel. (49) 621/7005-0
Fax: 1491 621/7005-200
Müacher {Munich}
Hewlett-Packard том
Eschenstrasse 5
82024 Taufkirchan
Tei: (49) 89/61412-0
Fax: (49) 89/61412-300
Nürnberg
Hewlett-Packard GmbH
Emmericher Strasse 13
90411 Nirnberg 10
Tel: (49) 911/0574-0
Fax: 1451 911/0524-140
Ratingen
Hewlett-Packard GmbH
Berliner Strasse 111
40880 Ratingen
Tel: (49) 2102/404.0)
Fax: (49) 2102/494-300
Ulm
riemett-Packarg GmbH
Messerschmitstrasse 7
89231 Neu Ulm
Tel {49} 731/7073-0
Fax: (431 731/7073-166
Waldbronn
Hewlett-Packard GmbH
Ermtis-Allee
76337 Waldbronn (Karisruhe)
Tel (401 7243/602-0
Fax: 148) 7243/602-512
Great Britain
See United Kingdom
Greece
G-Svsiems
Hewlelt-Packard Distributor
1, Hironos Street
11635 Athens
Tel: (30/1) 7250485
Fax: 130/11 7243477
Guatemala
PESA de Guatemala
Avenida Reforma 3-48, Zona $
Guatemala City
Tel: (502-2) 31-4786
Fax: (502-2) 31-6827
Telex: 3055765 IPESA GU
Hang Kong
An Asia Pacific
Headquarters Office
Hewlett-Packard (HK Lid.
22/F Peregrine Tower. Lippo
Centre я
8% Gueensway Central
Hong Kong
Tel (852) 848-7777
Fax: 1852) 840-1664
Telex: 78793 HPA НХ
Hungary
Hewiett-Packard Magyarorszag
Kit.
Erzsebel kiralyne utja 1/C
1146 Budapest
Tel 1/142-59-96
Fax. 1/122-36-92
India
Bangalore
Hewlett-Packard India Pyr Lig.
29 Cunningham Road -
Bangalore 560 052
Tel (91/812) 265-331
(91/812) 261-075
Fax (91/812) 200-196
Telex: 845-2773 HP IN
Bombay
Mewiett-Packard india Put. Ltd.
Ung-3, B-Wins
Ground Floor. Neelam Center
Hing Cycle Road
Woril, Bombay 400 018
Tel 161/22) 433-7821
($1722) 493-7823
Fax. (91/22) 493-9478
Telex: 11-76812 HPIB IN
Calcuta
Hewlett-Packard india Put. Lid,
DES Executive Centre
8 Acharya J.C. Bose Road
Caleutta 700-017
Tel: 191/33) 474-000
(91/33) 470-400
rax: (91/33) 474-614
Hyderabad
Hewlett-Packard india Put. Ltd.
9-5-13 Taramancal Complex
Sin Figor, Saifabad
Hydarabad 500 004
Tel: (91/842) 231-756
(91/842) 232-413
191/842) 241-574
Fax: (91/842) 841-697 (PP)
Telex: 425-644 PCO IN
Madras
Hewlett-Packard india Pyt. Utd.
DES Executive Centre
31-A Catedral Garden Road
Near Palmorove Hotel
Madras 600 034
Tel: (1/44) 479-186
(91/44) 475-191
Fax: (01/44) 825-7258
Teiex 41-8132
New Delhi
Mewlett-Packard india Pyt. Ltd.
Paharpur Business Centre
21 Nehru Place
Hew Deihi 110015
Tel (91/33) 470-4000
191/11) 647-2311
(91/11) 647-2328-30
Fax 191/111 646-1117
Telex: 31-71127 PAC IN
indonesia
PT. BERCA Hardayaperkasa
Ji Taman Tanah Abang i No. 31
Jakarta, Pusat
rei: 162/21) 370-758
(62/21) 185-5381
(62/21) 385-5387
(162/21) 375-194
Fax 162/21) 780-5166
ireland
Hewlett-Packard ireland Lid.
Hewlett-Packard House,
Stratibrook Road
Blackrock, Co. Dubtin
Ter: (353/1) 284-4633
Fax: 135371) 284-4622
Telex: 30430
Iran
Evertech
11 bis, rue Toepfier
1206 Geneve
Tel: 4122/3456 92 92
Fax: 4122/3465 86 91
Telex: 421 787 ©
Israel
Computation and Measurement
Systems (CMS) Lid,
11, Hashiosha Street
Tel-Aviv 67060
Tel: (9723) 538-03-80
Fax: (9723) 537-50-55
Telex: 371234 HPCMS
Italy
rewlett-Packard italiana Sp A.
Via G. di Vittorio 9
20063 Cemusco $/N (Mi
Tet (38/2) 92-121
Fax: 13972) 92-104-065
Anzala Emilia Bologna
Hewlett-Packard italiana $.0.A,
Via Ernitia. 51/C
40011 Anzola Emilia Bologna
Tei: {39/511 73-10-61
Fax: (39/51) 73-48-30
Bari
Hewlett-Packard Habana Sp A
Via Vitantomo di Caone, 34
70124 Bari
Tel: (39/80) 41-07-44
Fax: 139/80) 41-78-01
Limite
Hewlett-Packard Italiana S p A.
Via Nueva Flivoltana, 95
20090 Limito (MI)
Tel (39/2) 92-121
Fax: (39/2) 76-300-456
Nagai
Hewleti-Packard italiana Sp A.
Vig Emanuele Giantureo 92 6
80146 Napali
Tel (39/81) 73-40-1500
Fax: (39/61) 73-40-216
Района
Hewlett-Packard ltaliana S.p.A.
Localitá Camin
Via Belgio 4/0
35020 Padava
Те! (39/81) 82-94-41 1
Рах: (39/81) 87-01-8960
Roma Eur
Hewlett-Packard tatiana Sn A.
Viale del Tintoretto, 200
09142 Rama Eur
Tel: (39/6) 54-831
Fax: {39/6} 54-01-66 1
Torino
Hewlett-Packard Raliana 5.5 À.
Corso Svizzera, 185
10148 Torine
Tel: (39711) 74-271
Fax: (39/11) 77.168 640
Japan
An Asia Pacific
Headquarters Office
Yokogawe-Hewiett-Packard Lid.
91-1. Takauracho, Hachici-Shi
Tokyo 192 Japan
Tel (81/4) 2648-0652
Fax: (81/4) 2648-8064
Akita
Yokogawa-Hewlett-Packarg Ltd
Niñonseime: Akita Chuadori Blag.
4-2-7 Nakadon:
Akita 010
Tei: {81/188} 36-5021
Fax: (81/188) 36-5099
Atsugi
Yokogawa-Hewlett-Packarg Ltd —-
3-32 Tamuracho
Kanagawa 243
Tet: (81/482) 25-0031
"ах: {81/462} 25-0064
SALES OFFICES
Alphabetically by Country (cont'd)
Japan {cont'd)
Chiba
Yokogawa-Hewiett-Packard Lid,
WBG Malibu East Bigg. 19F
2-6 Nakase
Mihama-ky. Chiba-shi
Chiba 261-71
Tet: (81/43) 297-0581
Fax: (81/43) 297-0558
Fukuoka
Yokogawa-Hewlett-Packard Ltd.
Daisan Hakata-Kaisei Bidg.
1-3-6 Hakataeximinami Makata-ku
Fukuoka 812
— Tel (81/92 472-8731
Fax: (61/92) 473-4745
Hachioii
Yokogawa-Hewiett-Packard Lid,
9-1 Takakura-cho
Pachion-shi
Takys 192
Те! (81/426) 42-1261
Fax: (81/428) 45-2631
Hiroshima
Yokogawa-Hewiett-Packard Ltd.
Nisser-Hemwakoen Bidg. -
3-25 Nakajima-cho Naka-ku
Hiroshima 730
Tet (81/82) 241-0611
Fax: (81/82) 241-0619
Кобе
Yokogawa-Hewiert-Paciard Lig.
1-3-2 Muroya Nishi-ku
Кофе 551-22
Tel (81/78) 993-2600
Fax: (81/78) 992-2608
Koriyama
Yokogawa-Hewtett-Packart Ltd.
Mihon-Danta:-sermei Sidg.
21-10 Toramaru-machi
Koriyama 363
Tet (81/249) 39-7111
Fax (81/249} 39-7234
Kumagaya
Yokogawa-Hewiert-Pacraro Lid.
Nisser-Kumagaya Bidg
2-42 Miya-macr: Kumagaya-sfi
Saitama 360
Tel (81/485) 24-6563
Fax: {81/485} 24-9050
Kyoto
Yokogawa-Hewlett-Packard Lid.
Maeda NS Bldg.
518 Akinonc-machi Niiyo-Kudaru
Karasutna Nakakyo-ku
Kyoto 504
Tel: (81/75) 211-4301
Fax: (81/75) 211-2833
Mite
Yokogawa-Hewiet-Packard Lid.
Mito Mitsui Bldg.
1-4-73 Sannomaru
Mito 310
Tel: (81/2921 25-7470
Fax: (81/292) 31-8588
Miyazaki
Yokogawa-Hewiett-Packard Ltd.
Nomura Shoken Bldg.
4-1-2 Tachibana-dori
Miyazaki-C.
Miyazaki 880
Tet: (81/985) 23-7280
Fax: (81/985) 23-7864
Nagano
Yokogawa-Hewlett-Packard Lid.
Nagano-Tokyo-kaijo Bldg.
1081, Minamigata-mact:
Nagano 380
Tel: (81/262) 24-8012
Fax: (81/262) 24-8016
Nagaoka
Yokogawa-Hewiett-Packard Ltd.
Nagaoka ST Bldg.
2-5-11 Higashi-Sakanoue-cho
Nagaoka-shi
Nigata 940
Tel: (81/258) 32-4008
Fax: {81/258} 32-4006
Nagova
Yokogawa-Hewiett-Patkarg Lid
Nagoya Kokusar Center Bidg.
1-47-1 Nakorno, Nakamura-ku
Nagoya 450
Tel (81/52) 571-5171
Fax 181/02) 555-0896
Nara
Yokogawa-Fewlett-Packard Ltd
Nisser Nara Ekimae Sldo
1-1-15 Omva-cho
Nara 630
Tei (81/742) 22-8235 -
rax (81/742) 22-8219
Numazu
Yokogawa-Hewietl-Packard Ltd.
Nissei-Star Bldg,
4-8-23 Oemachi Numazu-shi
Shizuoka 410
Tel: (81/5591 52-2711
Fax; (81/559) 52-2722
Omiya
Yokogawa-Hewiett-Packard Ltd.
Mitsui-seimei Omiya Mivamach
Bldg.
2-96-1 Miyamachi Omiya-shi
Saitama 130
Tel: (81/48) 645-8031
Fax: {81/48} 645-8001
Osaka
Yokogawa-Hewlett-Packard Lid,
{Chuo Bldg.
5-4-20 Nishinakajima
Yodogawa-ku
Osaka 532
Tet: (81/6) 304-6021
Fax: {81/6) 304-0218
Sapporo
Yokogawa-Hewtett-Packard Ltd,
Sumitomo-seimei Sangoro Chuo
Bldg.
1-1-14 Nanig-higashi Chuo-ku
Hokkaido 060
Tel: (91/11) 251-1561
Fax: 181/11) 222-3239
Shinagawa
Yokogawa-Hewiert-Packard Ltd.
Tokyo-Nissan-Minato Bidg.
1-6-34 Konan, Minato-ku
Tokyo, 108
Tel: (81/3) 3458-5411
Fax: 181/2) 3458-1998
Suwa
Yokogawa-Mewiet-Packard Lid.
Damon Bidg.
138-1 Yaginish: Shimosuwa-cho
Suwa-Gun 393
Те! (81/256) 28-8851
Fax (81/266) 28-8873
Takaido
Yokogawa-Hewielt-Packard Lid.
3209-21 Takardo-Mgash:
Suginamiku
Tokyo 168
Tel (84/31 3331-6111
Telex. 232 2024 YHPTOK
Takasaki
Yokogawa-Mewiert-Packard Lia
Takasaki Daiichi-setmet Bldg.
116-1 Shin-Machi Takasaki-shi
Gunma 370
Tel: (81/273) 26-5168
Fax: (81/273) 26-5417
Tahaky
Yokogawa-Hewlett-Packard Lic.
Yamaguchi Bldg.
1-1-31 Ichibancho Aoba-ku
Sendai 980
Tel: (81/22) 225-1011
Fax: (81/22) 225-1616
Tokyo
Yokogawa-Hewiett-Packaro Ltd
shinjuku Datichi-seime: 8tdg.
2-7-1 Nishi-Shiniuku
ohinku-ku
Tokyo 163
Tel: (81/3) 3348-4611
Pax: (81/31 3348-7869 -
Toyota
Yakogawa-Hewietr-Packard Lto.
Tayota-Tokyo-Kario Bidg.
1-179 Miyuki-honmachi
Toyota 473
Tel: (81/565) 27-3611
Fax: {81/565} 27-5400
Tsukuba
Yokogawa-Mewlett-Packard Lid.
Tsukuba-Mitsui Bidg.
1-6-1 Takezono
Tsukuba 305
Tel: {81/298} 51-5141
Fax: (81/298) 51-5381
Utsunomivs
Yokogawa-Hewiett-Packard Ltd.
Chiyodaseimel-Utsunomsya Sido.
2-3-1 Odor
Utsunomiya 320
Tet (81/286) 33-1153
Fax: (81/286) 33-1175
Yokohama
Yokogawa-Mewietl-Packard Ltd
No. 2 Yasuda Bidg.
3-32-13 Tsuruvacho
Kanagawa-ku Yokohama-shi
Kanagawa 22*
Tel: (81/45) 317-1252
Fax: 181/45) 311-0279
Jordan
Scientific & Medical Supplies Co.
РО Вох 1387
Анива
Tet. 1962/6! 62-49-07
Fax: (962/6) 62-87-58
Telex: 21456 sabco 0
Korea
Samsung Hewlett-Packard Co.
Lid.
Samsung Building, 10-16/F
23-12 Yoidg-dong
Youngdeung no-ku
Seoul, 150-010
Ter: (82/21 769-0114
Fax: (82/2) 784-7084
Telex: SAM HP K25 166
Samsung Hewlett-Packard Co.
Lig.
13/F Taegu Bank Bldg.
118. 2-Ka. Suseong-dong
suseong-ku, Taagu
Tet (82/53) 754-2666
(82/53) 752-2696
Fax: (82/42) 752-4636
Samsung Hewlett-Packard Co.
Lid.
Ird E, Hang In Oficetel
536-8, Bong Myung-dong
Yusung-gu. Tasjeon
Tel: (82/042) 828-6710-4
Fax: (82/042) 828-6703
Malawi
Handied ty HiPerformance,
South Africa
Malaysia
Hewlett-Packard Sales (WM) SEN
BHD
Y Chung Khiaw Bank Bidg.
Section 46, Jalan Raja Laut
СРО Вох 11119
50736 Kuala Lumpur
Tet: (60/3) 298-6555
Fax: (60/2) 201-5465
Telex: MA 31011
Hewlett-Packard Sales {A} SON
BHO
9/F Wisma Penang Garden
4¢ Jalan Sultan Ahmad Shah
10050 Panang
Tel: (60/4) 376-532
160/64) 376-887
Fax: (60/4) 371-027
Telex: MÁ 41111
The Netheriands
Hewlett-Packard Nederland BY.
Posibox 667
1180 AR Amstelvaen
Tel: (31/20) 547-6069
Fax. (31/20) 647-8706
Kuwait
Ai-Khaidiya Electronics &
Electricals Equipment Co.
PQ Box 330
Safat 13008
Tel: (965/24) 59 815
Fax: 1985/24) 59 852
Lebanon
Computer information Systems
SAL
Jar-El-Dib, Main Road
CIS Bidg
Beirut 5274
PO Box 11-6274
Dora-Beirut
Tel: (561/1) 405-413
Fax: 135791 514-256
Telex: 42309 chacis le
Mauritus
Handied by HiPerformantce,
South Africa
New Zealand
Hewlett-Packard (NZ) Lid.
196-190 Willis Street
Р.О. Вох 9443
Wellington
Tet {64/4} 382-0400
Fax. (64/4) 384-3380
Nigeria
Management information Systems
Co Lid.
3 Gerrard Road
Р.О. Вох 53386
koy!, Layos
Tel: 01/6085 488
Fax: 01/685 487 (8)
Telex, 23582 DATEC NG
Mexico
Hewiett-Packard de Mexico
Monte Pelvoux No. 111
Col. Lomas de Chapultepec
11000 Mexico, D.F.
Tel: {52 5) 326-4000
Fax: (32 5) 540-4208
Morocco
SICOTEL
Complexe des Habous
Tour C avenue des Far
Casablanca 01
Tel: (212) 231-22-70
Fax: (212) 7231-65-45
Telex: 27604
Mozambique
Handied by HiIPertormance,
South Africa
Mambia
Handied by HiPertormance
South Africa
Norway
Hewlett-Packard Norge A/S
Drammansveien 163
PO Sox 60 Skoeven
№0212 0810
Tel: (47) 22-73-56-00
Fax: (47) 22-73-56-19
Hewlett-Packard Norge A/S
Roehmergt 44
N-5037 Solheimsviken
Tel: (47) 5529-00-06
Fax: (47) 55-29-10-72
Pakistan
Musho Clectronies (PVT) Lid.
58-W Sama Plaza
Biye Área, G-7
Isiamabad 44000
¡et (92/51) 816-190
(92/51) 628-469
Fax: 192/57) 821-201
Telex: 54007 Muski Pk
Mushiko Electronics (PVT) Lid.
Gasman Chambers
Abduilan Haroon Road
Karachi 74400
Tel: 192/21) 524-131
(82/21) 524-132
Fax: (92/21) 568-2298
Telex: 200%4 MUSKO PK
Panama
ciectronico Balboa, S.A.
Ave, El Paiscat #30
Edificio El Dorado
Apariado 4929
Panama 5
Tet: (507) 36-0722
Fax: (507) 36-1820
Telex: 368-3483 ELECTRON PG
Paraguay
ECSA Equinos Contables S.A.
{ite Estados Unidos No. 961
Asuncion
Те!: (595-21) 49-0075
тах: (595-21) 49-7849
Oman
IMTAC LLC
FA Box 51196
Mina ai Fanal
Muscat
Те! (968) 707-727
(968) 707-723
Fax (968} 796-639
(9681 797-708
Peru
Cia Ciectro Médica, S.A.
Los Flamencos No. 145
Oficina 301-302
Sar isidro. Lima 1
Tel: (51-14) 41-4325
Fax: (51-14) 42-5745
— Telex: 39425257 PE PE SIS
Philippines
The Online Advanced Systems
Carp. ;
2/7 Electra House
115-117 Esteban Street
Legasp: Village, Makati
Metro Manila
Tel: 163/2) 815-3810 10 16
Fax: (83/2) 816-0590
Telex: 63/2 663-274 ONLINE PN
SALES OFFICES
Alphabetically by Country (cont'd)
Poland
Mewiett-Fackard Palska
UN Neweiska 6
01-447 Warszawa
Tel: 22/375065
Fax: 22/374783
Telex: 813919
Portugal
Hewlett-Packard Portugal S.A,
Rua Gregorio Lopes. Lote 1732A
Torre de Santo António
1400 Listiga
Tel: (351/1) 301 7330
Fax: (351/11 301 633273
Puerto Rico
Howiett-Packard Puerto Rico
(3175)
Metro Office
Texaco Plaza, Suite 100
Cagarra Heights, PR 00920-
1705
Tel: (809) 792-7808
Fax: (809) 749-5325
Qatar
Gatar Datamations Systems
KDS Bidg. 2
Mezzanine Fioor
Chartered Bank Bldg.
Ai-Suda Sir.
PQ Bex 350
Doha
Tel: 974/44 19 16
Fax: 974/44 17 19
Telex: 4833
Romania
Barbatarı (Romania) Technics Sri
Hewlett-Packard Distributor
Caiea Dorobanti 103-105
El 6, Cam. 610 Sec 1
Bucurasti
Tet 1/3111291
Fax: 1/31109185
Saudi Arabia
Modern Electronics £stablisnment
РО. Вох 2769
King Abdul Azia Stree!
Ai-Khabar 31952
Tel (966/3) 895-6548
(966/3) 995-1764
Fax: (966/3) 094-4658
Telex: 871106 HPMEEK SJ
Cable: ELECTA, AL-KHOBAR
Modern Electronics Establishment
PO Sox 1228
Zaben Bldg.. Tahliah Sireel
Jeddah 21431
Tel (966/2} 661-1447
Fax: (966/2) 661-0857
Telex: 602712 FARNAS Sy
Cable: ELECTA, JEDDAH
Modern Electronics Establishment
Р.О Вох 22015
Prince Musad thn Abdulaziz Strat
Riyadh 11495
Tel {9668/1} 476-3030
Fax: {3966/1} 475-7649
(966/1} 475-2570
Telex: 402049 MEERYD SJ
Cable: ROUFKO
Singapore
Hewlett-Packard Singapore
{Sales} Pte. Lid,
150 Beach Road
#29-00 Gateway West
Singapore 0718
Tel: (65) 291-9088
Fax: (65) 206-8903
(65) 292-4526
Telex: 087-34209 HPSESO AS
- Slovak Republic
High Performance Systems
Hewlett-Packard Distributor
Pohanky 5
344 14 Bratislava
Tel: 7/760217
Fax: 7/763408
Slovenia, Croatia,
Macedonia
Hermes-Plus
Hewlett-Packard Distributor
Celovska 73
61000 Liubiiana
Slevenia
Tel: 61/193322
fax: 61/55597
South Africa
HiPerformance Systems (Py)
Lid.
PO Box 120. Howard Place
7450 Cape Town
Ter: (27/21) 685-7922
Fax: (27/21) 685-3785
MiPerformance Systems (Pty |
Ltd.
Private Bag, Wendywood
2144 Sandion
Tel (27/11) 006-1000
Fax: (27/11) 906-1713
Spain
Barcelona
Hewleit-Packard Espafioia, S.A
Avenida Diagonal, 605
08028 Barcelona
Те! {34/3} 401-91-00
Fax: (34/3) 4303-84-68
Telex: 52603
Bilbao
Hewiett-Packard Española S.A.
Edificio El Abra, 4
48930 Las Arenas. Guecho
Tel: 134/4) 481-80-00
Fax: (34/41 481-80-40
Telex: 33032
Madrid
Hewlett-Packard Española. SA,
Carretera Nacional VIGKm 16.500
28230 Las Rozas
Madrid
Tel: (34/1) 5626-15-00
Рах: (34/1) 626-18-30
Тех: 23515
Sevilia
Hewiet-Packard Española S.A.
Luis de Morales, 32
Edificio Forum
41018 Savilla Luis de Morales,
sn
Tel: (34/54) 53-70-10
Fax: {34/54) 53-30-97
Telex: 72933
Valencia
Mewiett-Packard Española SA.
Plaza de América, 2-52 Planta
46004 Valencia
Tel (34/6) 395-74-75
Fax: (34/6) 395-42-11
Telex 63435
Sri Lanka
Precision Technical Services
PPYTI Lia.
65/14. Park Street
Colomba 2
Tel: (941) 68779177
941) 687711
Fax 1941) 68771
Suriname
surtel. Co. Inc.
Grote Hotstraat 3-5
PO Box 185
Paramaribo
Tal (897) 47-7880
Fax: (597) 42-0053
Sweden
Güleborg
Hewlett-Packard Sverige AS
Vadurscaran 6
Box 5328
402 27 Gúteborg
Tel: (46/31) 35-18-00
Fax: 146/31) 35-19-09
Malmá :
Hewlett-Packard Sverige AB
vagersrovagen 160
Box 28066
200 28 Malmá
Tel: (46/40) 22-73-50
Fax: (46/40) 22-79-99
Service Office
Hewlett-Packard Sverige AB
Arabygatan
Box 3161
330 43 Мах о
Tel: (46/470) 396-08
Fax; {46/470} 396-07
Switzerland
Europe Headquarters Office
Hewlett-Packard SA
Route du Nant Амин 150
CH-1217 Meyrin 2
Geneva, Switzerland
Tel: (41) 22/780-81-11
Fax {41} 22/780-85-42
Telex: 419 019 hos
Middle East and Africa
Headquarters Office
Hewlett-Packard S.A
international Sales Branch
Middle East/Alrica
Rug de Veyrot 39
PO Box 364
1217 Meyrin 3
Geneva, Switzerland
Tel: (41/22) 780-4111
Fax: 141/22 785-4770
Telex: 4184607
Bern
Hewiett-Packard (Schweiz) AG
Meriedweg 11
CH-3172 Niederwangen/Bern
Те! (031) 980-31-13
Meyrin
Hewlett-Packard (Suisse} AG
39, rue de Veyrat
CH-1217 Mayrin 1
Tel: (022) 7850-41-11
Urdor?
Hewlett-Packard (Schweiz) AG
in der Luberzen 29
CH-8902 Urdori
Tel (41) 1.738 71 11
Fax: (441 14-735 77 00
Taiwan, ROG
Howlatt-Packard Tanwan Ltd..
11/F 456 Chung Hsiao 1st Road
Kaohsiung
Tai: (86/7) 241-2318
Fax: (686/7) 261-4619
Hewlett-Packard Taiwan Lid.
Ng. 20. Kao-Shuang Road
Ping-Chen 32404
Taoyuan Hsisn
Tei: (886/3) 492-9666
Fax: (886/3) 492-6087
Hewiett-Packard Talwan Ltd.
10/F 540, Sec.
\Nan-Hein Road
Taichung
Tel: (666/4) 327-0153
“ Fax: (686/4) 326-5274
rHewielt-Packard Taiwar: Ltd.
8/F Hewlett-Packard Building
Na. 337 Fu-Hsing North Read
Taipei 10483
Tel: (886/2) 712-0404
Fax: 1886/2) 718-2928
Telex. 078 924439 HEWPACK
Thailand
Hewiett-Fackard {Thailand} Ltd.
11/F Pacific Place
140 Sukhumvit Road
Bangkok 10110
Tel: 166/2) 254-6720
Fax: (66/2) 254-6731
Telex: 086 22094 HPTLSO TH
Trinidad and Tabago
Borde Communications
1 Vaisayn Road
Curepe, P.O. Box 897
Partot- Spain, Trinidad
Ter: (609) 663-2087
Fax. (809) 625-3352
Tunisia
Precisión Electronique
6 7ue de Chypre-—Mutuelte Vilie
1007 Tunis Belvedere |
Tel: 1216/1) 785-037
(216/1) 880-672
Fax: (216/71) 780-241
Telex: (0409) 18238 TELEC TN
Turkey
Ankara
Hewlett-Packard
Bilgisayar ve Oicum Sistemier!
ÁS.
Paris Cad No3 D.3
06670 Kavakiidera Ankara
Tel: 090 (4) 425-83-13
Fax: 090 14) 4725-47-45
Telex: 46180
istanbul
Hewlett-Packard
Bilgisayar ve Oicum Sistemier!
AS.
19 Mayis Caddesi, Nova/Baran
Plaza К. 12
Sist; 80220
Istanbul
Tel: {1) 224 59 25 (12 lines)
Fax: (1) 224 59 38
United Arab Emirates
emitac Ltd.
#0 Box 2711
Alu Dhabi
Tel (97172) 77-04-19
Fax: 1971/2) 72-30-58
Telex: 46306
Emitac Ltd.
Block RSB Arenco GiGG.
Zabel Road
PO Box 8381
Dubai
Tel: {97 1/4} 37-75-81
Fax: (971/4) 37-08-09
Telex: 48710
United Kingdom
England
Bracknell
Hewlett-Packard Limited
Cain Road
Вгаскией
Berkshire RG12 1HN
Tel: (44/344) 362-867
Fax: (44/344) 362-852
Telex: 349 358
Manehestar
Hewlett-Packard Limited
rieatrside Park Road
Cheadle Heath
Stockport
Cheshire SK3 ORB
Tel: (44/61) 428-0828
бах: 144/51) 495-5009
Telex: 668 068
United States
Alabama
Hewiett-Packard Co. (3114)
620 Discovery Drive
Hunisville, AL 35806
Tel: 1205) 971-2008
Fax: (205) 971-8899
Arizona
Hewlett-Packard Co. (2401)
8080 Pointe Parkway West
Phoenix, AZ 85044
Tet: 1602) 273-8006
Fax: (602) 273-8022
(602) 438-2355
Hewlett-Packard Co. (2406)
3400 € Rritannia Drive
Bldg. C. Suite 124
Tucsen, AZ 85706
Tel (602) 573-7400
Fax: 1602) 873-7408
California
Hewlett-Packard Co. {2403}
1421 S. Manhattan Avenue
Fullerton, СА 92631
Tet :7141 999-6700
Fax 1714} 758-7559
Hewiet-Packard Co. 12438)
130 Cremona. Suite À
Goleta, CA 93117
Tet: 1805: 685-6100
Fax: 1805) 685-6163
Irvine {see Fullerton;
Hewlett-Packard Co. (2417)
5245 Pacific Concourse Drive,
Quite 100
Los Angeles, CA 80045
Ter (316) 643-5112
Fax: {310} 535-2601
Hewlett-Packard Co. (2407)
491 £ Evelyn Avenue,
Bldg. 333
Mountain View, CA 94038
Tel: (415) 694-7000
Fax: (415) 694-2504
Mewlett-Packard Co (2415!
3831 N. Freeway five.
Sacramento, CA 05634
Tel: (916) 567-8500
Fax: (915) 567-8777
(916) 567-9778
Hewlett-Packard Co. (2404)
0506 Aero Drive
San Diego, CA 92123
Tel: (519) 279-3200
Fax: (619) 268-8487
(619) 279-0560
Santa Barbara /see Goteta?
Hewlett-Packard Co {2428}
5806 Senuiveda Blvd. Suite 690
Van Nuys, CA 91411
Tel: (418) 786-5800
Fax: 1818) 779-2350
Ventura (see Van Nuys)
Colorado
Hewlett-Packard Co. (2441)
2005 Center Green Drive, Suite
205
Boulder, CO) 80301
Tel: (303) 938-3065
Fax: (303) 938-3025
Hewlett-Packard Co. (2411)
24 inverness Place East
Englewcod, CO 80112
Tel: (303) 649-5000
Fax. 1302) 649-5787
Connecticut
Hewlett-Packard 06. (4457)
4 Siamiord Forum, 9in Floor
Stamiord, C7 0650
Tal: 1203) 324-1003
Fax: (2031 325-5680
SALES OFFICES
Alphabetically by Country (cont'd)
United States (cont'd)
Hewlett-Packard Co, (4458)
115 Glastonbury Blvd.
Giastonbury, CT 06033
Tel: (203) 533-8100
Fax: (203) 659-6087
District of Columbia
{see Rockvilla, MO)
Figrida
Latin America
Headquarters Office
Hewlett-Packard Co.
5200 Blue Lagoon Drive, 8th Floor
Miami, FL 33126
Tel: (308) 267-4245
Fax: {305) 267-4288
Hewlett-Packard Co. (317%
5800 N. Andrews, Suite 100
Fort Lauderdale, FL 33309
Ter: (305) 938-9800
Fax: (305) 938-2293
Hewlett-Packard Co. (3171)
255 €. Drive, Suite 8
Maibourns, FL 32904
Tet: (407) 729-0704
Fax: (407) 952-7801
Hewlett-Packard Co. {3177}
6177 Lake Ellencr Drive
Orlando, FL 32808
Tel: (407) 859-2800
Fax: (407) 826-9308
Hewigtt-Packard Co. (3166)
5556 Idlewild, Suite 150
Tampa, FL 33634
Tel: (813) 884-3282
Fax: (813) 889-4445
Georgia
Hewiett-Packard Co. (3108)
1995 N. Park Place
Atlanta, GA 30339
Tel: (404) 955-1500
Fax: 1404) 980-7010
Hawaii
Hewlett-Packard Co (2408)
3660 Waiaiae Avenue, Suite 102
Honolulu, +11 95816
Ter: (808) 732-1566
Hlinais
Hewiett-Packard Co (2519
2205 E. Empire Street
Bigomington, IL 61704
Tel: (309) 567-9411
Fax (309) 662-0351
Hewlett-Packard Co. (2603)
1200 €. Dieht Hoad
Kapervilie, IL 50566
Tel: (7081 505-8800
Fax: (708) 505-7876
Hewlett-Packard Co. {2601}
5201 Totiview Drive
Rolling Meadows, IL 60008
Tel: (708) 255-9800
Fax: (708) 255-4995
Indiana
rewlett-Packard Co. (2605)
201 М 103rd Street. Suite 166
indiananolis, IN 46200
Tel: (317) 844-4100
Fax: (317) 843-1291
Hewlett-Packard Co. (2635)
111. Ludwig Road, Suite 108
FL Wayne, № 46825
Tel: {219} 482-4283
Fax: (219) 480-3730
lowa
Hewlett-Packard Co. (2612)
4050 River Center Court
Cedar Rapids, ¡A 52402
Tel: (319) 393-0606
Fax: 13191 378-1024
Kansas
Hewlett-Packard Co. {2622)
Р.О. Всх 780408
3450 N. Rock Acad, Suite 300
Wichita, KS 67278
Tel: (316) 635-4040
Fax: (316) 636-4504
Kentucky
Hewiett-Packard Co. (2623)
305 N. Hurstbourne Parkway
Suite 100
Louisville, KY 40222-5141
Tel: {502} 426-0100
Fax: (502) 426-0322
Maryland
Hewlett-Packard Co. 14432)
3701 Koppers Street
Baltimore, МО 21227
Tel (410) 644-5800
Fax: [4101 362-7650
Hewlett-Packard Co. {443014400
2101 Gaither Road
Rockvilla, MO 70850
Tel (301) 258-2000
Fax. (301) 258-5586
Massachusatis
Hawiett-Packard Co. (44501
29 Burlington Mali Road
Burlington, MA 01803-4182
Tel: (617) 270-7000
Fax 1617) 221-5240
Michigan
Hewlett-Packard Co (2617)
3033 Qrchard Vista SE. Suite
100
Grand Rapids, Mi] 49546
Tel: (616) 957-1970
Fax: (616) 956-0022
Hewlett-Packard Co. (2607)
39550 Orchard Hiil Place Drive
Novi, Mi 48376
Tel: (313) 349-9200
Fax: 1313) 349-9243
Minnesota
Hewlett-Packard Ca. (2606)
2025 W. Larbenteur Avenue
St, Paul, MN 55113
Tel: (512) 644-1100
Fax: (512) 641-9787
Missouri
Mewielt-Packard Co. 2611)
6601 Winchester Avenue
PO Box 18230
Kansas City, MC 64133-8230
Tel: (816) 737-0071
Fax: (816) 737-4690
Hewlett-Packard Co. (2610)
530 Maryvilie Centre Drive
St. Louis, MO 63141
Tel: 13141 542-1508
Fax: (314) 542-1585
Nebraska
Mewlett-Packard Co, (2616)
2933 N. 117h Avenue
Omaha, NE 68164
Tel: (402) 493-0300
Fax: 1802) 493-4334
New Jersey
Hewiett-Packard Co. (4415)
West 120 Century Road
Paramus, NJ 07653
Ted: (207) 599-5000
Fax: 1201) 599-5387
Hewett-Packard Co (6417)
25 New England Avenue, Wes!
Piscataway, N 08854
Tel (908) 562-6100
Fax: 1908) 562-6246
New Mexico
Hewlett-Packard Co. (2452!
5130 Masthead NE.
Albuquerque, NM 87109
Tel: 1505) 823-6100
Fax: (505) 823-1243
Hewlett-Packard Co. (2420)
1362-C Trinity Drive
Las Alamos, NM 87544
Tel: (506) 662-6700
Fax: (505) 662-4317
New York
Hewlett-Packard Co. (4444)
114 Great Gaks Office Park 77
Albany, NY 12203
Tel: (518) 452-0947
Fax: (518) 452-8989
Buttalo (see Cheektowaga,
HewiettPackard Co. 14445)
Airport Commerce Park
305 Cayuga Agar, Suite 160
Cheaklowaga, NY 14225
Tel: (716) 264-4100
Fax: 1716) 264-4150
Hewiert-Packard Co (4442!
29G Woodclhift Drive
Fairport, NY 14450 -
Tet: {716) 264-4000
Fax: (716) 264-4150
Huntingtan (sec Melville;
Hewlett-Packard Co. (4440)
5010 Campuswood Drive
East Syracuse, NY 13057
Tel: (315) 463-2727
Fax: {315} 483-3150
Hewlett-Packard Co. 14411
7 Old Sod Farm Acad
Maiviile, NY 11747
Tel: (516) 753-0585
Fax: (516) 753-3469
Rochester (see Fairnort;
Hewlett-Packard Co. 14409)
Executive Square Office Bidg
66 Middiebush Road
Wappingers Fall, NY 12505
Tel: (914) 288-3125
Fax: (914) 708-3338
North Carolina
Hewiett-Packard Ce. {31421
2000 Regency Parkway. Suite 800
Cary, NC 27511
Tel: (919) 467-6600
Fax: (919) 460-2296
(919) 460-2297
Hewlett-Packard Co. {3145)
9401 Arrownoirt Bivo.
Charlatte, NC 28210
Tel: 1704) 527-8780
Fax: 1704) 538-7444
Hewlett-Packard Co, (3111)
7029 Albert Pick Road, Suite 100
Greensbora, NC 27409
Tel: 19101 665-1800
Fax: (919) 668-1797
Mailing Address
PO Sox 26500
Greensboro. NC 27476
Raigigh sec Gary}
Ohio
Hewlett-Packard Co. {2624}
4501 Erskine Road
Cincinnati, 0 45242
Tel: (5131 891-0870
Fax: (513) 891-0033
Cleveland /see Strongsvilie/
Mewett-Packard Co 10714)
540 Office Center Place
Columbus, 0H 43230-5321
Tel: 1614) 478-6200
Fax: 1614) 478-6299
Hewlett-Packard Co. (2604)
7887 Washington Village Drive
Dayton, OH 45459
Tel: (5131 433-2223
Fax: (513) 433-8633
Heweit-Packard Co. 12608)
15885 Sprague Road
Strongsville, ОН 44136
Tel: 1216) 743-7300
Fax: 1216) 234-7220
Oklahoma
Hewlett-Packard Co. 131821
3525 NW 56ih Street, Suite C
Oklahoma City, OK 73112
Tel: 1405) 946-9498
Fax: (405) 648-4760)
Hewlett-Packard Co (3183)
66555 Lewis, Suite 105
Tulsa, (GK 74136
Tel {918} 481-2285
Fax: (918) 481-2250
Oregon
Hewlett-Packard Co. (24133
15115 SW Sequoia Parkway,
Suite 100
Poriland, OR 97224
Tel: (503) 598-8000
tax: (503) 596-8155
Penssyivania
Hewlett-Packard Co. (2608)
177 Zeta Drive
Pittsburgh, PA 15238
Tel: (412) 782-0400
Fax: (412) 784-3340
Hewlett-Packard Co (4420)
2750 Monros Bivd,
Valley Forge, PA 19482-0713
Tel: (215) 666-9000
Fax: (215) 666-2034
Tenneses —
Hewlett-Packard Co. 13H17
404 BNA Drive
Nashville, TN 37217
Tel: (615) 367-4700
Fax: (615) 399-4616
Texas
riewiett-Paciard Co. (3197)
9050 Canital of Texas Hwy, North
Suite 290
Austin, TX 7875
Tel: (512) 346-3855
Fax: (512) 238-7278
Dalias /sec Richardson)
Hewlett-Packard Co. 124051
5700 Cromo Drive, Site 100
£l Paso, TX 70917
Tel (915) 833-4400
Fax: 1915) 833-4444
Hewlett-Packard Co. (3187)
2000 W. Loop South
Houston, TX 77047
Tel {713) 439-5300
Fax: 1713) 439-5495
Mewiett-Packard Co. {3185}
930 £. Campbell Road
Richardson, TX 75081
Tel 1214) 231-5107
Fax: 12141 599-4337
Hewlett-Packard Co (3188)
14100 San Pedro Avenue, Suite
100
San Antonio, TX 78232
Tel (512) 494-9336
Fax: 1512) 491-1799
Utah
Hewlett-Packard Co. (2412)
3530 W. 2100 S.
Sait Lake City, UT 84116
Tel: (8011 974-1700
Fax: 1901) 974-1780
Virginia
Chesapeake (see Glen Alien)
Hewlett-Packard Co. (3113)
4401 Waterfront Drive, Suite 150
Glen Alten, VA 23050
Tel: 804) 747-7750
Fax: (804) 965-9207
Nortolk (see Glen Alien)
Richmond /see Gian Allen)
Raanoke (see Glan Alten)
Washington
Hewiel-Packard Co. 12410)
15815 5.£. 371 Street
Believe, YA 38006
Tel: 1205) 643-4000
Fax: (206) 643-8748
Wisconsin
Hewlett-Packard Co. (2615)
275 N. Corporate Drive
Brookfield, Wi 53045
Tel: (414) 7972-8800
Fax: (414) 792-0218
Uruguay
Conatel SA.
Ejido No. 1696
Montévidaa
Tef: 1598) 292-0314
(598! 292-0660
Venezuela
Hewlett-Packard de Venezuela
Ma Transversal Los Ruices Norte
Edificio Segre Pisos 1,2. y 3
Caracas 1071
‘el (58-21 239-4244
Fax {58-21 238-4008
(58-2) 239-3080
Zambia
Handled by HiPerformance,
South Africa
Zimbabwe
see South Africa;
PLEASE SEND DIRECTORY
CORRECTIONS TO:
Test & Measurement Catalog,
S41 -AF
Hewlett-Packard Company
5301 Stevens Creek ВМ.
Р.О. Вох 58059 a
Santa Ciara. CA 98052-8059
Tel: (408) 553-7271
Fax: (408) 983-1006 -