Voltage Monitors PLM Series The PLM Series continuously measures the voltage of each of the three phases. The PLM Series uses a microcontroller circuit design that senses undervoltage, voltage unbalance, phase loss, and phase reversal. Protection is assured when regenerated voltages are present. Both delta and wye systems can be monitored; no connection to neutral is required. For more information see: Appendix B, page 165, Figure 8 for dimensional drawing. Appendix C, page 168, Figure 13 for connection diagram. Features: •Protects against phase loss & reversal; & under & unbalanced voltages •8-pin plug-in base •Adjustable low voltage trip point •Factory fixed unbalance & trip delay •Line voltages 200 to 480VAC in 3 ranges •Isolated, 10A, SPDT output contacts •ASME A17.1 rule 210.6 •NEMA MG1 14:30, 14:35 •IEEE C62.41-1991 Level B Approvals: Auxiliary Products: Operation The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed. Field Adjustment: Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required. • Panel mount kit: P/N: BZ1 • Octal 8-pin socket: P/N: OT08PC • 3-phase fuse block/disconnect: P/N: FH3P • 2 Amp fuse: P/N: P0600-11 • DIN rail: P/N: C103PM (Al) Available Models: PLM6405 PLM6502 PLM6805 PLM8405 PLM8805 PLM9405 PLM9502 PLM9805 PLM9820 If desired part number is not listed, please call us to see if it is technically possible to build. Order Table: PLM X Line Voltage ─6 - 240VAC ─8 - 380VAC ─9 - 480VAC Specifications X Voltage Unbalanced ─Fixed - Specify - 4-8% in 1% increments X Trip Delay ─Fixed - Specify from 2-20s in 1s increments using two digits Line Voltage Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-phase delta or wye with no connection to neutral Operating Voltage: Model Adj. Line Voltage Range Line Voltage Max. 240 200-240VAC 270VAC 380 360-430VAC 480VAC 480 400-480VAC 530VAC AC Line Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . 50/100 Hz Phase Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABC Power Consumption. . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 2W for 240V units ≅ 3W for 380 - 480V units Low Voltage & Voltage Unbalance Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage detection with delayed trip & automatic reset Low Voltage Trip Voltage. . . . . . . 88 - 92% of adjusted line voltage Reset Voltage.. . . . . Plus 3% of trip voltage Voltage Unbalance Trip Unbalance . . . . Factory fixed from 4 - 8% Reset on Balance . . -0.7% unbalance typical Trip Delay Range . . . . . . . . . . . . Factory fixed from 2 - 20s Tolerance. . . . . . . . . ±15% Phase Reversal & Phase Loss Response Time: Phase Reversal. . . . . . . ≤ 200ms Phase Loss. . . . . . . . . . . ≤ 200ms 114 Phase Loss. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 35% unbalance Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automatic Output Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical relay Form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Isolated, SPDT Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A resistive @ 240VAC, 277VAC max; 1/2 Hp @ 240VAC; 1/4 Hp @ 120VAC 5 7 Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical - 1 x 10 ; Electrical - 1 x 10 Protection Surge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEEE C62.41-1991 Level B Isolation Voltage . . . . . . . . . . . . . . . . . . . . . . . ≥ 2500V RMS input to output Mechanical Mounting*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-pin plug-in socket rated 600VAC Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm) Environmental Operating / Storage Temperature . . . . . . . . -40° to 60°C / -40° to 85°C Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 4.4 oz (125 g) *CAUTION: Select an octal socket rated for 600VAC operation. www.ssac.com • 800-843-8848 • fax: 605-348-5685 Appendix B - Dimensional Drawings FIGURE 1 FIGURE 2 FIGURE 3 CT; ESD5; ESDR; FS100; FS200; FS300; KRD3; KRD9; KRDB; KRDI; KRDM; KRDR; KRDS; KRPD; KRPS; KSD1; KSD2; KSD3; KSD4; KSDB; KSDR; KSDS; KSDU; KSPD; KSPS; KSPU; KVM; T2D; TA; TAC1; TAC4; TDU; TDUB; TDUI; TDUS; TL; TMV8000; TS1; TS2; TS4; TS6; TSB; TSD1; TSD2; TSD3; TSD4; TSD6; TSD7; TSDB; TSDR; TSDS; TSS; TSU2000 HLV; HRD3; HRD9; HRDB; HRDI; HRDM; HRDR; HRDS; HRID; HRIS; HRIU; HRPD; HRPS; HRPU; HRV; RS HSPZ FIGURE 4 FIGURE 5 TRDU FIGURE 6 TRU FA; FS; FSU1000*; NHPD; NHPS; NHPU; NLF1*; NLF2*; PHS*; PTHF*; SIR1; SIR2; SLR1*; SLR2*; TH1; TH2; THC; THD1; THD2; THD3; THD4; THD7; THDB; THDM; THDS; THS *If unit is rated @ 1A, see Figure 1 FIGURE 7 FIGURE 8 FIGURE 9 PLM; PLR; TDB; TDBH; TDBL; TDI; TDIH; TDIL; TDM; TDMB; TDMH; TDML; TDR; TDS; TDSH; TDSL FS500; PRLB; PRLM; PRLS; TRB; TRM; TRS (snap for mounting bases) ASQU; ASTU; DSQU; DSTU FIGURE 11 FIGURE 12 FIGURE 10 FS100; FS400 ERD3; ERDI; ERDM www.ssac.com • 800-843-8848 • fax: 605-348-5685 ORB; ORM; ORS inches (millimeters) 165 Appendix C - Connection Diagrams FIGURE 1 - FSU1000 Series L1 FIGURE 2 - FS100 Series L1 N/L2 S1 = Optional low current switch V = Voltage L = Load FIGURE 3 - FS100 Series L1 N V = Voltage L = Load R = Red Wire B = Black Wire FIGURE 5 - FS300 Series FIGURE 4 - FS200 Series N/L2 V = Voltage L = Load V = Voltage L = Load FIGURE 6 - FS400 Series L1 FIGURE 7 - AF Series L1 N/L2 FIGURE 8 - FS500 Series N/L2 L1 V = Voltage L = Load Note: Load may be in positive side. FIGURE 9 - SC3/SC4 Series L1 V = Voltage L = Load R = Red Wire B = Black Wire W= White Wire V = Voltage N/L2 V = Voltage L = Load FIGURE 11 - DLMU Series FIGURE 10 - WVM Series N/L2 ! SC4 shown; for SC3, terminal 6 & load L4 are eliminated. FIGURE 12 - HLMU Series L1, L2, L3 = Line Voltage Input NO = Normally Open Contact NC = Normally Closed Contact C = Common, Transfer Contact CAUTION: 2 amp max. fast acting fuses are recommended to protect the equipment‘s wiring. They are not required to protect the DLMU. ! = Select alarm contact connection as N.O. or N.C. when ordering; N.O. Shown. F = Fuses NO = Normally Open NC = Normally Closed RS = Optional Remote Reset Switch Relay contacts are isolated. CAUTION: 2 amp max fast acting fuses must be installed externally in series with each input. (3) FIGURE 14 TVM/TVW Series FIGURE 13 PLMU/PLM/PLR/PLS Series Note: Relay contacts are isolated, 277VAC max. L1, L2, L3 = Line Voltage Input NO = Normally Open Contact NC = Normally Closed Contact C = Common, Transfer Contact CAUTION: 2 amp max. fast acting fuses are recommended to protect the equipment‘s wiring. They are not required to protect the HLMU. 168 F = Fuses ØA = Phase A = L1 ØB = Phase B = L2 ØC = Phase C = L3 NO = Normally Open NC = Normally Closed 2A fast acting fuses recommended for safety (not required) Relay contacts are isolated. L1 = Phase A L2 = Phase B L3 = Phase C NO = Normally Open NC = Normally Closed C = Common, Transfer Contact Relay contacts are isolated. F = 2A Fast acting fuses are recommended, but not required www.ssac.com • 800-843-8848 • fax: 605-348-5685
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement