Catalogue - Chauvin Arnoux
Catalogue
About the
CHAUVIN ARNOUX GROUP
Founded in Paris, France in 1893, CHAUVIN ARNOUX has spent the
centuries since then developing its expertise in the design, manufacture
and marketing of measuring instruments for professionals.
From handheld instrumentation to fixed electrical equipment and energy
performance systems, and from control of the entire thermal process
chain to industrial metrology, the CHAUVIN ARNOUX Group's offering
meets every customer requirement across all the sectors (self-employed
electricians, industry, government bodies, etc.).
"CHAUVIN ARNOUX is a major
player in the measurement market in
France and internationally."
A Few Figures
•
•
•
•
•
•
Your partner:
- energy performance
- regulatory testing
- environmental measurements
- installation supervision and sizing.
10 subsidiaries worldwide
900 employees
6 production sites
6 R&D departments worldwide
11% of revenues invested in R&D
Turnover of 100 million euros
4 expert measurement
companies in one Group
Portable test and measurement
instrumentation
Metering, measurement
and energy performance
Temperatures in industrial
processes
Metrology and regulatory
testing
Contents
Applications
• Industrial and tertiary applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
• Housing applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Testers and Multimeters
•
•
•
•
Digital multimeter clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Two-pole Voltage Absence Testers (VATs). . . . . . . . . . . . . . . . . . . . . . . . . 10
Digital multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Portable oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electrical Testing and Safety
•
•
•
•
•
Assessing the safety of installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical installation testers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulation testers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Earth and resistivity testers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Earth and resistivity testers with adapter
for pylon earth measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Earth and resistivity kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Earth clamps and loop testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Micro-ohmmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Single-phase ratiometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power, Energy and Disturbances
•
•
•
•
Symptoms of disturbances on an electrical network . . . . . . . . . . . . . . . . . .
The standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power analysers for three-phase electrical networks. . . . . . . . . . . . . . . . . .
Power and energy loggers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
17
18
21
22
22
23
24
24
25
25
25
30
Environmental Measurements
• No-contact thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
• Light meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
• Tachometers and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Current Measurements
•
•
•
•
AC and AC/DC current measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Oscilloscope measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ammeters with flexible sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flexible current sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
33
34
35
Test and Measurement Accessories
• Measurement leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
• Protection and transport accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Industrial or Tertiary Applications
PEL103
F605
Power and Energy Loggers
Power consumption monitoring
Harmonics
Energy metering
3 000 ADC
2 000 AAC/AC+DC
1 000 VAC/DC/AC+DC
Powers
single phase
and total three-phase
Harmonic analysis
Phase rotation
TrueInrush
C.A 6555
10 kV / 15 kV
Insulation Tester from
10 kΩ to 30 TΩ
DAR / PI / DD /∆R
(ppm/V) ratios
F65
Measurement of leakage currents and
live-line detection of insulation faults
Qualistar® Range
C.A 6417
Earth loop
measurement
4
C.A 5277
TRMS AC, DC and
AC+DC digital multimeters
Testing, maintenance
and verification
1000 VAC/1000 VDC
600 V CAT IV / 1000 V CAT III
DigiFlex
Current
measurement
HANDSCOPE
Range
For maintenance:
oscilloscope,
harmonic analyser,
dual multimeter
and recorder,
USB communication
C.A 8230
Measurement of power
and energy quality.
The ideal tool for initial
detection of harmonics
F205
Current up to
600 AAC / 900 ADC
Voltage up to 1000 V
Min/Max/Peak/∆Rel
C.A 6525
Insulation measurement (with
installation power off) and
continuity measurement
MTX Mobile
High-accuracy
recorder-multimeter
MX 57Ex
ATEX multimeter for difficult environments
(gas and dust)
MX 24 Concept
Multi-purpose TRMS multimeter
C.A 6549
Insulation resistance
measurement at 5 kV
(with installation power off)
DAR/PI/DD/C/I,
Ramp mode
5
Applications habitat
F203
600 AAC
900 ADC
1 000 VAC/1,000 VDC
Temperature with K thermocouple:
- 60 °C to +1,000 °C
RELative ∆X
Differential ∆X/X(%)
C.A 6456
Earth tester
C.A 811
Lighting measurement
MN21
6
C.A 760N
Two-pole
Voltage
Absence
Tester
C.A 6116N
Electrical installation testing
F403
1,000 AAC
1,500 ADC
1,000 VAC/DC
Single-phase and total
three-phase power values
Frequency analysis
RELative ∆X
Differential ∆X/X(%)
C.A 6523
Insulation and continuity
measurement
MX 22
Continuity, voltage,
current and Min/Max
C.A 871
Checking of thermal
diffusion in a room
C.A 5275
7
Testers and Multimeters
Digital multimeter clamps
3 series of clamps for 3 measurement ranges:
discover our range and choose your clamp!
F200
F400
600 AAC / 900 ADC
Voltage up to 1,000 V
+
Resistance, audible continuity
2 000 AAC / 3 000 ADC
+
F201 / F401 / F601
F203 / F403 / F603
F205 / F405 / F605
F407 / F607
AC applications
AC or DC applications
Mixed AC+DC
applications + testing
and maintenance
Mixed AC+DC
applications + analysis
and verification
Everything you need for
installations and equipment
powered by the mains supply
DC current
Temperature
Adapter function
ΔREL
The Adapter function
can be used to extend the
instrument's capabilities
through the use of
measurement probes (light
meter, I/R temperature,
tachometer, etc.) with voltage
output (AC or DC). A clever
system then allows users
to directly read the quantity
measured.
8
F600
1 000 AAC / 1 500 ADC
Power
THD
ΔREL
Min/Max/Peak
Phase rotation
Power
Harmonics
Ripple
Recording
PC software
Phase rotation
For determining the phase
order, the use of a "2-wire"
microprocessor-controlled
measurement system
removes the constraints
and faults encountered
with instruments based
on resistive or capacitive
technologies when using
protective accessories
(gloves, mats, etc.) or
isolating transformers.
Ripple
Ripple is a parameter used
to quantify the quality of the
smoothing when currents are
rectified and then smoothed.
The lower the ripple, the
greater the effectiveness of
the smoothing.
In the case of a switching
power supply, the voltage
supplied includes residual
ripple, particularly at high
frequencies. This ripple
is harmful for electronic
equipment and must
therefore be kept to a
minimum.
F400 Series
Low and medium-power LV applications
● 1,000 Aac (or ac+dc) / 1,400 Adc
● Clamping diameter 48 mm
● TRMS acquisition
● TrueInRush function
F600 Series
High-power LV applications
● 2,000 Aac (or ac+dc) / 3,000 Adc
●
Clamping diameter 60 mm
●
TRMS acquisition
● TrueInRush function
F201
F203
P01120921 P01120923
Reference
Specifications
Clamping diameter
Display
LCD
Resolution
Number of values displayed
Autorange function
Automatic AC/DC detection
Aac
Adc
Best accuracy
Vac
Yes
0.15 to 600 A (900 A peak)
Best accuracy
Frequency of V / I
Resistance
60 kΩ
Audible continuity
Diode test (semi-conductor junction)
Adapter
Single-phase and total three-phase
power values
temperature
(K type)
active (W)
reactive (VAR)
apparent (VA)
FP / DPF
Adjustable from 1 Ω to 599 Ω
Yes
Yes
Yes
Yes
Yes
Yes / No
THDf / THDr
TRMS
[AC]
TRMS
[AC]/DC
F603
P01120963
Yes
Yes
1
TRMS
[AC]
-
1 000 A
1,500 A peak
1,000 A
(1,500 A peak)
1 % R + 3 counts
1 ,000 V
TRMS
[AC]/DC
Yes
3, 000 A
2,000 A
(3,000 A peak)
1 % R + 3 counts
1, 000 V
1 ,400 V
Yes / -
Yes / Yes
Adjustable from 1 Ω to 999 Ω
Adjustable from 1 Ω to 999 Ω
1,000 A
(1,400 A peak)
1 % R + 3 counts
100 kΩ
Yes
Yes
Yes
°C: -60.0 to +1,000.0 °C /
°F: -76.0 to +1,832 °F
Yes / -
No
No
Yes
Yes
Yes
Yes
Yes / Yes
Yes / -
25th order
Yes
Load evolution (TrueInrush)
Yes
Yes
Yes
Peak+ / PeakRELative ∆X
Differential ∆X / X(%)
Auto Power Off
Data recording
Communication interface
Electrical safety according to IEC 61010
Power supply
Dimensions / Weight
Warranty
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
25th order
Yes
Yes
Oui
Yes / Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes / Yes
Yes
Yes
Yes
°C: -60.0 to 1,000.0 °C /
°F: -76.0 to +1,832 °F
Yes / Yes
Yes
1,000 A
(1,400 A peak)
1 % R + 3 counts
100 kΩ
Yes
Min / MAX
Yes
2 ,000 A (3 ,000 A peak)
Yes
Hold
3
TRMS
[AC, AC+DC]/DC
1, 400 V
Yes
F607
P01120967
10,000 counts
3
Functions
Overcurrent measurement
Motor Inrush
F605
P01120965
Ø 60 mm
TRMS
[AC, AC+DC]/DC
Yes / Yes
Phase rotation (2-wire method)
F601
P01120961
Backlit LCD
1
Yes
Yes
°C: -60.0 to +1,000.0 °C /
°F: -76.0 to +1,832 °F
F407
P01120947
10,000 counts
Yes
0.15 to 1,400 V
0.15 to 1,000 V
(1,400 V peak)
1% R + 3 cts
Vac+dc
Frequency analysis
TRMS
[AC, AC+DC]
/DC
F405
P01120945
Backlit LCD
6,000 counts
TRMS
[AC]/DC
F403
P01120943
Ø 48 mm
Backlit LCD
0.15 to 1,000 A (1,400 A peak)
Vdc
F401
P01120941
Ø 34 mm
0.15 to 900 A peak
0.15 to 600 A
(900 A peak)
1 % R + 3 counts
Aac+dc
Harmonic analysis
F205
P01120925
1
TRMS
[AC]
Type of acquisition
IP
54
1000 V CAT IV
Yes
Yes
Yes
Yes
Yes
Bluetooth
Yes
Yes
Yes
600V CAT IV
1, 000 V CAT IV - 1, 000 V CAT III
1 ,000 V CAT IV - 1 ,000 V CAT III
78 x 222 x 42 mm / 340 g
92 x 272 x 41 mm / 600 g
111 x 296 x 41 mm / 640 g
1 x 9 V LF22
4 x 1.5 V AA
3 years
Yes
Bluetooth
4 x 1.5 V AA
9
Testers and Multimeters
Voltage Absence Testers (VATs)
> C.A 740N & C.A 760N
Comply with Edition 2 of the IEC 61243-3 standard
l
Fulfil the requirements of the EN 50110-1 standard
l
C.A 740N
Specifications
C.A 760N
Voltage Absence Tester
Voltage
12 VAC ≤ U ≤ 690 VAC
12 VDC ≤ U ≤ 750 VDC
Frequency
DC, 16 2/3 à 800 Hz
Impedance
> 300 kΩ
> 400 kΩ
Max. peak current
3,5 mA RMS
Polarity indication
Oui
Redundant dangerous voltage
indication
The red ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage)
and the higher the voltage present, the faster it flashes
Phase / Neutral identification
Above 50 V (45 – 65 Hz) / Above 150 V (16 2/3 – 45 Hz)
Continuity with buzzer
Trigger threshold
100 Ω typical (150 Ω max.)
Extended continuity test
2 kΩ, 60 kΩ, 300 kΩ
Test current
≤ 1 mA
Open-circuit voltage
≤ 3.3 V
Protection
up to 1,000 V
Phase rotation
Ph/Ph voltage
Buzzer
No
2-wire method
—
50 V ≤ U ≤ 690 VAC (45 - 400 Hz)
Intermittent beep for voltage detection / Continuous beep for continuity
Standards and electrical safety
CEI 61010 600 V CAT IV
Enclosure protection
Casing: IP65 – Test probes (option): IP2X
Climatic conditions
Operation from -15 °C to +45 °C / 20 to 95% RH
Power supply
Battery life
2 x 1.5 V batteries (AAA or LR3)
7,500 x 10s measurements
Dimensions / weight
State at delivery
1 voltage absence tester delivered in blister pack with
1 black Ø 2 mm test-probe lead with crystal safety
cover, 1 red Ø 2 mm test probe with crystal safety
cover, 1 wrist strap, 2 x 1.5 V LR03/AAA batteries
& 1 operating manual in 5 languages.
IP2X version: delivered with 1 set of IP2X Ø 4 mm
test-probe leads 0.85 m long (black) and 0.25 m long
(red), 1 wrist strap, 2 x 1.5 V LR03/AAA batteries and
1 operating manual in 5 languages.
10
7,000 x 10s measurements
163 x 64 x 40 mm / 210 g
References and accessories
C.A
C.A
C.A
C.A
740N................................................................................................................... P01191741Z
760N................................................................................................................... P01191761Z
740N IP2X.......................................................................................................... P01191741B
760N IP2X.......................................................................................................... P01191761B
Adapter for 2P+E sockets......................................................................................... P01101997Z
Spare red test probe for VAT compliant with IEC 61243-3....................................... P01102008Z
Spare black test-probe lead for VAT compliant with IEC 61243-3........................... P01102009Z
Adapter for safety rod................................................................................................ P01102034
Crystal safety cover for D2 test probe (x 10)............................................................ P01102033
Set of 2 leads 0.25 m and 0.85 m long with Ø 4 IP2X test probes.......................... P01295285Z
Set of 2 leads 1.5 m long with Ø 4 IP2X test probes................................................ P01295462Z
Soft case, 200 x 100 x 40 mm.................................................................................. P01298065Z
Wrist strap................................................................................................................. P03100824
Multifix bag, 120 x 20 x 60 mm................................................................................. P01298074
TRMS AC, DC, AC+DC digital multimeters
Category IV for safety,
versatility for use in the field
IP
54
600 V CAT IV
C.A 5271
Display
C.A 5273
6,000 counts
Bargraph
61 + 2 elements
Acquisition
C.A 5275
2 x 6,000 counts with backlighting
61 + 2 elements, dual mode (full scale/central zero)
TRMS AC /DC
Measurement range
C.A 5277
TRMS AC / DC / AC+DC
5 measurements / second
Autorange / Deactivatable
Yes / No
Automatic AC /DC detection
Ranges
Yes / Yes
Yes
No
600 mV / 6V / 60V / 600 V / 1,000 V
60 mV / 600 mV / 6 V / 60 V / 600 V / 1,000 V
V DC
Typical accuracy
0.2 % + 2 cts
0.09 % + 2 cts
Resolution
0.1 mV to 1 V
0.01 mV to 1 V
V AC
600 mV / 6 V / 60 V / 600 V / 1,s000 V
60 mV / 600 mV / 6V / 60 V / 600 V / 1,000 V
Resolution
0.1 mV to 1 V
0.01 mV to 1 V
Bandwidth
40 Hz to 3 kHz
40 Hz to 10 kHz
VLow AC (low impedance
+ low-pass filter)
V AC + DC
Ranges
Ranges
600 mV / 6V / 60V / 600V / 1,000 V
Resolution
0.1 mV to 1 V
Ranges
60 mV / 600 mV / 6V / 60 V / 600 V / 1,000 V
Resolution
0.01 mV to 1 V
Ranges
A DC
A AC
A AC + DC
Resistance
Audible continuity
6 A / 10 A (20 A / 30 s)
6,000 µA / 60mA / 600 mA / 6 A / 10 A (20 A / 30 s)
0.001 A to 0.01 A
Resolution
1 µA to 0.01 A
Ionization current: 0.2 µA to 20.0 µA
Ranges
6 A / 10 A
Resolution
6,000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A / 30 s)
0.001 A to 0.01 A
1 µA to 0.01 A
Ranges
6,000 µA / 60 mA / 600 mA / 6 A / 10 A (20 A / 30 s)
Resolution
1 µA to 0.01 A
Ranges
600 Ω / 6,000 Ω / 60 kΩ / 600 kΩ / 6 MΩ / 60 MΩ
Resolution
0.1 Ω to 0.1 MΩ
Yes
Test diode
Hz
Capacity
T°
Hold
Yes
Ranges
600 Hz / 6 kHz / 50 kHz
Resolution
0.1 Hz to 10 Hz
Ranges
6 nF / 60 nF / 600 nF / 6 µF / 60 µF / 600 µF / 6 mF / 60 mF
Resolution
-59.6 °C to +1,200 °C
-4 °F to +2,192 °F
Ranges
Resolution
0.1° to 1 °
0.1° to 1 °
No
Peak+ / Peak- (1 ms)
Yes
Differential measurement (X) / Relative (DX/X%)
Automatic power-off
No
Yes
No
Yes
Yes (deactivatable)
Power supply
1x9V
Dimensions / Weight
90 x 190 x 45 / 400 g
C.A 5270 multimeter delivered with a set of banana leads, a set of test probes, a 9 V battery and
a CD containing the operating manual and the start-up guide.
C.A
C.A
C.A
C.A
To order
-59.6 °C to +1,200 °C
-4 °F to +2192 °F
Hold
Min / MAX (100 ms)
State at delivery
0.001 nF (1pF) to 10 µF
5271
5273
5275
5277
standard state
with additional
with additional
with additional
at delivery
K thermocouple temperature sensor
bag and Multifix adapter
K thermocouple temperature sensor, bag and Multifix adapter
C.A 5271 TRMS AC/DC multimeter
P01196771
C.A 5273 TRMS AC/DC multimeter
P01196773
C.A 5275 TRMS AC+DC multimeter
P01196775
C.A 5277 TRMS AC+DC multimeter
P01196777
11
Universal Testing and Measurement
Digital multimeters
IP 67
The MX 57Ex is certified ATEX & IECEx
and can be used in both explosive and
non-explosive environments.
The MX HD range of IP 67
multimeters fulfils the requirements
for difficult environments.
They are totally protected against:
- dust
- the effects of temporary immersion
MX0022-Z
MX0024-G
MX 24B
MX 44HD
MX 58HD
MX 59HD
MX 57Ex
4,000 counts
5,000 counts
4,000 counts
5,000 / 50,000 counts
50,000 counts
50,000 counts
Type of measurement
AVG
TRMS
AVG
DC voltage
600 V
1,000 V
1,000 V
600 V
750 V
750 V
Bandwidth
500 Hz
1 kHz
1 kHz
50 kHz
400 µA,
4-40-400 mA,
4 A, 10 A
500 mA/10 A
40 mA/10 A
5 mA, 50 mA
500 mA, 20 A (30s)
Frequency
4 MHz
500 kHz
–
Range from 0.62 Hz to 500 kHz
Resistance
40 MΩ
50 MΩ
6 ranges from
400 Ω to 40 MΩ
6 ranges from 500 Ω to 50 MΩ
Detection threshold from 10 Ω to 20 Ω - resp. time 1 ms
Reference
Display
Bargraph
AC voltage
AC/DC current
other measurements
Audible continuity
Diode test
Capacitance
Temperature
Other measurements
Protection rating
Safety
Dimensions
Weight
State at delivery
12
MX 22
MX0044HD
MX0058HD
Yes
< 40 Ω
10 to 20 Ω
20 to 40 Ω
0à4V
0 to 2 V
0 to 3 V
–
50 nF to 50 mF
4 nF to 40 µF
–
–
–
Min / Max
Min / Max
MX0059HD
MX0057CX
Analogue, 34 segments, 20 meas./s
TRMS AC & AC+DC
5 calibres from 500 mV to 600 V
5 calibres from 500 mV to 600 V
100 kHz
50 kHz
500 µA, 5 mA, 50 mA and 500 mA
20 A (30s)
from 0 to 2 V
7 ranges from 50 nF to 50 mF
-200 °C to +800 °C / Pt100 and Pt1000 probes
–
Duty cycle
– dB function
Duty cycle
IP 40
IP 67
Duty cycle
– dB function and U2/R
resistive power
Pulse width – timer
Event counting
CAT III 600 V
CAT III 600 V
IEC 61010-1
CAT IV 600 V
170 x 80 x 35 mm
189 x 82 x 40 mm
230 x 155 x 65 mm
ATEX 94/9/CE directive,
EN/IEC 60079-0-EN:
IEC 60079-11,
EN/IEC 61241-11-EN/IEC
61241-0,
EN/IEC 61010-1-600 V
CAT III, CE inspection
certificate type LCIE 02
ATEX 6005X &
additional clauses
01, 02, 03, 04
189 x 82 x 40 mm
300 g
400 g
500 g
400 g
Elastomer sheath, set of 2 safety
leads, 9 V battery (installed),
verification certificate and
operating manual
Set of safety test-probe
leads, protective
sheath, 2 x 1.5 batteries,
2 fuses installed and
operating manual
Set of PVC safety
test-probe leads,
protective sheath,
9 V battery, 2 fuses
installed and
operating manual
Set of silicone safety
test-probe leads,
protective sheath,
9 V battery, 2 fuses
installed and
operating manual
Carrying case, set
of safety test-probe
leads, 1 spare
intrinsic-safety fuse,
operating manual
Digital multimeters
MTX Mobile range
Reference
Display resolution
Analogue display
Graph of measurements over time
Backlighting / Auto power-off
TRMS measurements
Basic accuracy for DC voltage
Bandwidth
AutoPeak for crest factor
Measurements available
AC & DC voltage ranges
Basic accuracy for AC voltage
AC & DC current
Basic accuracy for DC / AC current
Single A terminal / simultaneous U & I
Resistance / Continuity test
Frequency / Period / Duty cycle
Pulse width / Metering
Capacitance / Diode test
Temperature Pt100/1000 / J/K TC
dBm / Resistive power
U & I peak / Crest factor
Measurement processing
Display hold
Min / Max / Avg monitoring
Relative measurements
Measurements of physical quantities
Measurement storage
Time/date-stamping
SPEC function
Interfaces (depending on model)
Measurement processing
EMC / Safety
V/A selection / Input alarm
Orientable protected display
Electronic switch
Protected battery/fuse access
"Closed-case" software calibration
MTX 3283
MTX 3282
MTX 3281
Multimeters in the MTX Mobile family:
Direct one-handed access to the functions thanks to the electronic measurement switch
• Large orientable graphic LCD screen • Dedicated "A" or "V" measurement terminals allowing
automatic selection of the corresponding function, in mode AC +DC with automatic range by default
• Optical RS232 and USB ports, BlueTooth port
See below
1 or 4 simultaneous displays of 100,000 counts each
Fast bargraph associated with the graph or the digital measurements
automatic display of the measurements from the last 60 s
backlighting time adjustable from 10 s to permanent / Activatable by the user
AC & AC+DC for voltages and currents
0.02 % +8 D
0.03 % +8 D
0.1 % +8 D
200 kHz
100 kHz
50 kHz
detection and automatic management of the crest factor of the signals measured
ranges from 100.000 mV to 1,000.00 V
0.3 % +40 D
0.7 % +40 D
ranges from 1,000.00 mA to 20.000 A
0.08 % +8 D / 0.3 % +30 D
0.08 % +8 D / 1 % +30 D
automatic ranges on single A terminal, 1 fuse / using 3 leads
Ranges from 1000.00 Ω to 50.000 MΩ / 5 ms fast continuity test
0.6200 Hz to 2.000 MHz / yes / yes
100 μs to 12.5 s / 99,999
no / no
ranges from 10.00 nF to 10.00 mF / from 0 to 2.6000 V
yes / yes
no / yes
yes / yes
no / no
periodic or single peaks lasting 250 ms min. / calculation of signal crest factor
0.3 % +40 D
Manual (Hold) Or Automatic On Stable Measurement (AutoHold)
calendar date and time
relative date and time
absolute deviation, deviation in % and reference / display of frequency and deviation in dB
"Favourite measurement" key , scaling and physical unit
6,500 measurements + graph
4 x 150 measurements + graph
calendar date and time
relative date and time
display of the instrument’s tolerances for each type of measurement
insulated optical RS232 / insulated optical USB / wireless BlueTooth (100 m without obstructions)
emission and immunity as per EN61326-1 / IEC61010 Cat. IV-600 V, Cat. III-1,000 V
automatic according to lead position / buzzer and visual alarm for A
use on benchtop or worn on belt (hands-free) / protection during transport
no more mechanical failures / all-round safety management
separate compartments with mandatory disconnection of leads
optimization of adjustments (optional SX-MTX328x calibration software)
State at delivery
References
MTX3281B: MTX 3281 delivered with 1 set of banana leads Ø 4 mm,
3 x LR6 batteries, HRC fuse, 10 x 38 mm 1,000 V-T11A-20 kA, and
an abbreviated operating manual in 5 languages
MTX3281B-COM: MTX3281B + USB cable and SX-DMM software
MTX3282B-COM: MTX3282B + USB cable and SX-DMM software
MTX3283B-COM: MTX3283B + USB cable and SX-DMM software
MTX3282B: MTX 3282 delivered with 1 set of banana leads Ø 4 mm,
3 x AA NiMH rechargeable batteries with mains adapter/charger, HRC fuse,
10 x 38 mm 1,000 V-T11A-20 kA, and an abbreviated operating manual in
5 languages
MTX3281B-BT: MTX3281B + Bluetooth and SX-DMM software
MTX3282B-BT: MTX3282B + Bluetooth and SX-DMM software
MTX3283B-BT: MTX3283B + Bluetooth and SX-DMM software
MTX3283B: MTX 3283 delivered with 1 set of banana leads Ø 4 mm,
3 x AA NiMH rechargeable batteries, HRC fuse, 10 x 38 mm
1,000 V-T11A-20 kA, and an abbreviated operating manual in 5 languages.
MTX3281B-P: Delivered in hard case with HX0052 "hands-free" kit
and 1 MN09 current clamp, 1 set of 2 crocodile clips, 1 set of 2 hook
wire-grips, 1 CD-Rom containing the operating manuals in 5 languages
MTX3282B-P: Delivered in hard case with HX0052 "hands-free" kit and
1 K-thermocouple probe adapter, 1 USB cable and SX-DMM acquisition
software, 1 set of 2 crocodile clips, 1 set of 2 hook wire-grips, 1 CD-Rom
containing the operating manuals in 5 languages
MTX3283B-P: Delivered in hard case with HX0052 "hands-free" kit and
1 banana lead with clamp for SMD components (HX0064), 1 USB cable
and SX-DMM acquisition software, 1 set of 2 crocodile clips, 1 set of 2 hook
wire-grips, 1 CD-Rom containing the operating manuals in 5 languages
13
Earth Clamps
and Loop Testers
IP
40
600 V CAT IV
C.A 6416
Loop ohmmeter
1,500-count display
C.A 6417
Measurement ranges (Ω) / Resolution (Ω) / Accuracy
0.010 to 0.099 / 0.001 / ±1.5 % ±0.01
0.10 to 0.99 / 0.01 / ±1.5 % ±2 r
1.0 to 49.9 / 0.1 / ±1.5 % ±r
50.0 to 99.5 / 0.5 / ±2 % ±r
100 to 199 / 1 / ±3 % ±r
200 to 395 / 5 / ±5 % ±r
400 to 590 / 10 / ±10 % ±r
600 to 1150 / 50 / Approx. 20 %
1200 to 1500 / 50 / Approx. 25 %
Measurement frequency: 2083 Hz /
Transposition frequency: 50, 60, 128 or 2083 Hz
Frequency
Loop inductance measurement
Measurement ranges (μH) / Resolution (μH) / Accuracy
10 to 100 / 1 / ±5 %±r
100 to 500 / 1 / ±3 %±r
Contact voltage
Measurement ranges (V) / Resolution (V)
0.1 to 4.9 / 0.1
5.0 to 49.5 / 0.5
50.0 to 75.0 / 1
Ammeter
Measurement ranges (A) / Resolution (A) /
Accuracy
4,000-count display
Measurement ranges (A) / Resolution (A) / Accuracy
0.200 to 0.999 mA / 1 μA / ±2 % ±50 μA
1.000 to 2.990 mA - 3.00 to 9.99 mA / 10 μA / ±2 % ±50 μA
10.00 to 29.90 mA - 30.0 to 99.9 mA / 100 μA / ±2 %±r
100.0 to 299.0 mA - 0.300 to 0.990 A / 1 mA / ±2 %±r
Setup
Modes
Alarms
Buzzer
HOLD
Automatic power-off
General specifications
Display
Max. clamping diameter
Storage
Communication
Power supply
Battery life
Calibration
Electrical safety
Protection
Dimensions
Weight
1.000 to 2.990 A - 3.00 to 39.99 A / 10 mA / ±2 %±r
Standard or advanced
Configurable on Z, V and A
Active
Manual or automatic PRE-HOLD
Active / Inactive
152-segment OLED. Active area 48 x 39 mm
Ø 35 mm
300 time/date-stamped measurements
2,000 time/date-stamped measurements
Bluetooth Class 2
4 x 1.5 V LR6 (AA) alkaline batteries or 4 x Ni-MH batteries
1440 x 30-second measurements
Automatic at start-up
IEC 61010 600 V CAT IV
IP40
55 x 95 x 262 mm
Approx. 935 g with batteries
State at delivery
• C.A 6416: 1 clamp delivered in a hard case with
4 x 1.5 V batteries, 1 CD-Rom containing the
operating manual in 5 languages
• C.A 6417: 1 clamp delivered in a hard case with
4 x 1.5 V batteries, 1 CD-Rom containing the
operating manual in 5 languages and the GTT
software with simplified driver
References and accessories
• C.A 6416. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > P01122015
• C.A 6417. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > P01122016
•
•
•
•
L1 calibration loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
C
DataView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Bluetooth USB modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Hard case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
P01122301
P01102095
P01102112
P01298080
23
Electrical Testing and Safety
Micro-ohmmeters
C.A 6240
C.A 6250
P01143200
P01143201
Low-level resistance measurements
Reference
Measurement method
Resistance
Resolution
Accuracy
Current
Current inversion
Measurement mode
Temperature
compensation
Power supply
Electrical safety
Dimensions
Weight
State at delivery
4-wire method
400 μΩ to 400.0 Ω
1 μΩ to 2,500 Ω
1 µΩ
0.1 µΩ
0.25 %
10 mA to 10 A
0.05 %
1 mA to 10 A
No, but automatic compensation
of eddy currents
Yes
Inductive, non-inductive, non-inductive with automatic triggering
no
Manual or with Pt 100 probe
NiMH rechargeable battery
IEC 61010-1 / Cat III 50 V
270 x 250 x 180 mm
4.5 kg
4 kg
Mains power cable / leads with Kelvin clamps / software /
optical /USB communication cable / bag
Electrical equipment tester
DTR 8510
Range of ratios (VT)
Accuracy (VT)
Range of ratios (TC)
Accuracy (TC)
Excitation signal
Excitation current display
Excitation frequency
Display
Available languages
Measurement method
Power supply
Battery life
Battery charger
Charging time
Storage
Date / time
Communication
Software
Dimensions / Weight
Connection
Leads
Casing
Vibrations
Shocks
Falls
Protection rating
Safety
State at delivery
24
Digital ratiometer for transformers
Automatic: 0.8000 to 8,000:1
Range of ratios
Accuracy (% of reading)
0.8000 to 9.9999
± 0.2 %
10.000 to 999.99
± 0.1 %
1000.0 to 4999.9
± 0.2 %
5000.0 to 8000.0
± 0.25 %
Autoranging: 0.8000 to 1000.0
± 0.5 % of reading
VT mode: 32 Vrms max
CT mode: Auto level 0 to 1 A, 0.1 to 4.5 Vrms
Range: 0 to 1,000 mA; Accuracy: ± (2 % R + 2 mA)
70 Hz
Alphanumeric LCD, 2 lines of 16 characters with adjustment of contrast and
backlighting. Easy to read in both daytime and nighttime conditions
French, English, Spanish, Italian, German, Portuguese
According to IEEE Std C57, 12.90™ -2006 standard
Two rechargeable batteries: 12 V, NiMH, 1650 mAH
Up to 10 hrs in continuous operation, low-battery warning
Universal input (90 to 264 Vrms), smart charger
< 4 hours for full charge
10,000 tests
Power supplied by dedicated battery, real-time clock
USB 2.0, optical isolation, 115.2 kB
Delivered with DataView® analytical software
272 x 248 x 130 mm / 3.7 kg
XLR connectors
Screened H and X leads, length 4.6 m (15 ft),equipped with colour-coded
crocodile clips
Rugged polypropylene casing, UL 90 V0
IEC 68-2-6 (1.5 mm at 55 Hz)
IEC 68-2-27 (30 G)
IEC 68-2-32 (1 m)
IP 40 with cover open as per EN 60529
IP 53 with cover closed as per EN 60529
EN 61010-1, 50 V CAT IV; pollution degree 2
Delivered with a carrying bag containing 1 set of 4.6 m leads with crocodile
clips, 1 external battery charger with mains power cable, 1 USB cable,
1 NiMH battery datasheet, 1 operating manual and DataView software on
CD-Rom
Power, Energy, Disturbances
Symptoms of disturbances on an electricity network
Qualimetry is a major focus for many companies, not least because of its financial benefits.
Before raising the issue of a diagnosis of their electrical system, it is worth knowing the different symptoms,
listed in the table below, which indicate faults in an installation.
DC
co
mp
on
Th
en
r
t
e
un e-p
ba
h
a
lan se
ce
Fre
va que
ria nc
tio y
ns
Ex
po cess
we re
ac
r
tiv
EM
e
C
SYMPTOMS
Flic
ke
r
Bro
wn
-ou
ts
Un
de
r-v
olt
Ov
ag
ere
v
Atm olta
g
su osp e
rge he
ric
s
Ha
rm
on
ics
Int
erha
rm
Ho
on
ics
ha morm po
on lar
ics
Mi
cro
-ou
tag
Sh
ort
es
po
we
Lo
rc
lon ng a
uts
g o nd
uta ver
ge y
HF
s
sp
ike
s
Po
w
su er
rge
s
POSSIBLE
ORIGINS
Processes operate
erratically
Random stoppages
of process equipment
Process stoppages
Damage to equipment
Overheating and noise
from equipment
Malfunctions
on motors
Abnormal vibration
and noise on motors
Stoppages of motors
Malfunction
of the electronic
Malfunction
of electronics
Erratic operation
of protection systems
Untimely tripping
of protection systems
Non-operation
of protection systems
Triggering of arcs
Problems with monitors
Problems
with radio-communications
Computer
and telecom interference
Destruction
of PCBs
Destruction
of computer hardware
Flicker of lighting
Electrocution
Fire of electrical origin
The standards
EN 50160
IEC 61000-4-30
IEC 61000-4-7
Defines the method for
measuring harmonics
and interharmonics
IEC 61000-4-15
Defines the flicker measurement
method including:
• Pst short-term flicker indicator:
Quantitative evaluation of the flicker
over a 10-minute period.
• Plt long-term flicker indicator:
Quantitative evaluation of the flicker
➜
Defines the methods
and accuracies for
the power quality
measurements listed in
the EN 50160 standard
(rms voltage, outage,
voltage dips and swells,
unbalance,...).
➜
Defines the
measurements
required to qualify
the voltage delivered
by the electrical grid:
rms voltage, outages,
voltage dips, swells,
flicker, frequency,
harmonics (up to the
40th order) and
three-phase system
unbalance.
over a 2-hour period, using
12 successive short-term flicker
(Pst) values.
25
Power, Energy, Disturbances
Electrical energy analysers for three-phase networks
CAT
IV
•5 voltage inputs and 4 current inputs
•10-minute Inrush mode
•Calculation of distorting power
•IP67: all-terrain model available
IEC 61000-4-30
IEC 61010
1000 V CAT III
600 V CAT IV
IP
67
IEC 61000-4-30
C.A 8331
Number of channels
Number of inputs
Voltage (TRMS AC+DC)
Current (TRMS AC+DC) Frequency
Power values
Energy values
Harmonics
3U / 4I
4V / 3I
Voltage ratio
THD
Expert mode
-
Min/Max
of a selection of parameters at max. sampling rate
4 hrs to 2 weeks
Alarm
Peak
Vectorial representation
Display
Capture of screens and curves
Electrical safety
Protection
Languages
Battery life
Communication interface
Power supply
Dimensions
Weight
Warranty
26
C.A 8336
2 V to 1,000 V
Up to 500 kV
C.A 8435
4U / 4I
5V / 4I
MN93 : 2 to 200 Aac ; MN93A : 0,005 Aac to 100 Aac
MN clamps
C193 clamp
AmpFlex® or MA clamps
PAC93 clamp
E3N clamp
Current ratio
Transients
Flicker (Pst and Plt)
Inrush mode
Unbalance
Recording
IEC 61000-4-30
C.A 8333
12
—
1 A to 1 000 Aac
100 mA to 10 000 Aac
30 A to 6 500 Aac
1 A to 1 000 Aac+dc
50 mA to 10 Aac/dc – 100 mA to 100 Aac/dc
Up to 60 kA
40 Hz to 69 Hz
W, VA, var, VAD, PF, DPF, cos φ, tan φ
Wh, varh, VAh, VADh
Yes
Yes, orders 0 to 50, phase
Yes
50
210
Yes
Yes over 4 periods
Yes > 10 minutes
Yes
Yes
A few days
2 weeks to several years
to several weeks
4,000 of 10
10,000 of 40 different types
different types
Yes
Automatic
TFT colour ¼ VGA screen, 320 x 240, diagonal 148 mm
12
50
IEC 61010 1,000 V CAT III / 600 V CAT IV
IP53 / IK08
IP67
More than 27
Up to 13 hours
USB
9.6 V NiMH rechargeable battery or mains power supply
Yes with DataView®
Yes with DataView® software
—
software
240 x 180 x 55 mm
270 x 250 x 180 mm
1.9 kg
3.7 kg
3 years
State at delivery
C.A 8336 • C.A 8333 • C.A 8331 – Models without sensors
Qualistar+ analyser delivered with a bag for accessories, 5 x 4 mm banana voltage leads 3 m long,
5 crocodile clips, 12-colour identification kit for the leads and inputs, anti-scratch screen-protection film
(mounted), USB cable, mains power cable, mains power pack, safety datasheet, 1 CD containing multilanguage operating manual and 1 CD containing PC software for data recovery (Power Analyzer Transfer).
C.A 8435 AMP450
Delivered with bag no. 22, USB cable, IP67 mains power cable, 4 AmpFlex® 450 IP67 A196 current
sensors, 5 x IP67 BB196 black banana leads, 5 lockable crocodile clips, 12-colour identification kit for the
leads and inputs, anti-scratch screen-protection film (mounted), USB cable, mains power cable, mains
power pack, safety datasheet, 1 CD containing multi-language operating manual and 1 CD containing PC
software for data recovery (Power Analyzer Transfer).
References
• C.A 8336 alone . . . . . . . . . . . . . . . . . > P01160591
• C.A 8333 alone. . . . . . . . . . . . . . . . . . > P01160541
• C.A 8331 alone. . . . . . . . . . . . . . . . . . > P01160511
• C.A 8435 alone. . . . . . . . . . . . . . . . . . > P01160585
• C.A 8435 AmpFlex® 450 mm. . . . . . . > P01160587
Software
The measurements performed with the Qualistar models can be processed using two software products:
(standard) and
(option).
Configuration of the instrument: setup, recording, alarms
Real-time display
Processing of recorded data and alarms
Transfer of printouts of screenshots and transients
Data export into Excel spreadsheet
Data export in graph form in Windows™











The easy-to-use
software automatically recognizes the
instrument connected to the PC and opens the corresponding menu.
Users have direct access to:
database management
management of reports according
to the voltage quality standards




 

















 
 

   

 

 






 
  
 
 
   

    

 
 
   
 
 
   
 
   






















•
•
•
•
is compatible with other Chauvin Arnoux® products:
Qualistar+ power analysers
C.A 8220 & C.A 8230 power analysers
F400 and F600 multimeter clamps
and other measuring instruments
Minimum operating system required:
Windows® 2000, Windows® XP, Windows® Vista, Windows® 7 and 8.
Reference






 





  




 


 

 
 

 



     









 




     



     




 









     









 




     





     




 









     









 


   


 













































 
 
    
    
    
    
    
    
    
    
    
    
    
    
    
 






• Dataview® software . . . . . . . . . . . . . . > P01102095
27
Power, Energy, Disturbances
Essailec accessory for all the Qualistar + models
A lead with an ESSAILEC plug can be used to perform tests without
disturbing or interrupting the power supply circuit on meters and
protection relays installed in the secondary circuits of current or voltage
transformers. The main advantage is the speed and simplicity of
measurement with maximum user safety.
Accessory for electrical cabinets equipped with Essailec connectors.
Clamps for Qualistar +
Model
Measurement range
Clamping Ø /
length
IEC 61010
MN93
MN 93A
MA193
PAC93
A196-450
A193-450
A193-800
C193
E3N
0,5 to
200 Aac
0,005 Aac
to 100 Aac
100 mA to
10k Aac
1 A to 1000 Aac
1 A to 1300
Adc
100 mA
to 10 k Aac
100 mA to
10k Aac
1 A to
1000 Aac
50 mA to
10 Aac/dc
100 mA
to 100 Aac/dc
20 mm
20 mm
70 mm /
220 mm
1 x Ø 39 mm
2 x Ø 25 mm
Ø 450 mm
140 mm
Ø 800 mm
250 mm
52 mm
11,8 mm
600 V CAT
III / 300 V
CAT IV
600 V CAT III /
300 V CAT IV
1000 V CAT III
/ 600 V CAT IV
600 V CAT III /
300 V CAT IV
1000 V CAT
III / 600 V
CAT IV
1000 V CAT III
600 V CAT IV
/ 600 V CAT IV
600 V CAT III /
300 V CAT IV
Available accessories - References to order
ESSAILEC unit.................................................. >
MN93 clamp...................................................... >
MN93A clamp.................................................... >
MiniFlex® MA193, 200 mm............................... >
PAC93 clamp.................................................... >
AmpFlex® A196 450 mm IP67.......................... >
AmpFlex® clamp, A193 450 mm....................... >
AmpFlex® clamp, A193 800 mm....................... >
C193 clamp....................................................... >
E3N clamp......................................................... >
E3N adapter...................................................... >
E3N mains power pack..................................... >
Battery pack...................................................... >
Qualistar screen film......................................... >
Set of rings-inserts............................................ >
28
P01102131
P01120425B
P01120434B
P01120580
P01120079B
P01120552
P01120526B
P01120531B
P01120323B
P01120043A
P01102081
P01120047
P01296024
P01102059
P01102080
Set of 5 x IP67 banana leads
3 m long (BB196).............................................. > P01295479
Bag no. 21......................................................... > P01298055
Bag no. 22......................................................... > P01298056
USB-A USB-B cable.......................................... > P01295293
5 A unit.............................................................. > P01101959
Lockable crocodile clips (x 5)............................ > P01102099
Kit comprising banana leads (x 5), crocodile clips (x 5)
and 1 set of coloured rings................................ > P01295483
Kit comprising banana leads (x 4), crocodile clips (x 5)
and 1 set of coloured rings................................ > P01295476
Set of plugs (C.A 8435)..................................... > P01102117
Mains power pack (C.A 8335)........................... > P01102057
IP67 mains power cable (C.A 8435)................. > P01295477
Power analysers for three-phase electrical networks
CAT
III
Reference
Voltage
AC current
DC current
C.A 8220
C.A 8230
Specially designed for motor maintenance
Access to all the measurements simultaneously
Low-resistance and high-current measurements
Large colour screen
Intuitive use
Excellent price-quality ratio
Recording
Alarms
P01160620
Accuracy
Accuracy
Accuracy
Values
Fundamental frequency
Display
P01160630
6 Vrms to 600 Vrms AC+DC
± (0.5 % + 2 cts)
5 mA to 6,500 A
± (0.5 % + 1 ct)
1 A to 1,400 A
± (1% + 1 A)
Min, max, avg. Peak (+ and -), crest factor
40 Hz to 70 Hz
Backlit LCD with 3 displays of 173 segments
VGA colour LCD (320 x 240)
Single-phase and
balanced three-phase
Power measurements
Energy
Harmonics
Recording
Alarms
PST flicker
Functions
Phase rotation
Motor inrush
current display
Motor rotation speed
Temperature (Pt 100)
Resistance (winding)
Measurement storage
Use
Ambient temperature
Relative humidity
Protection rating
USB optical port
Safety
Power supply
Weight
Dimensions
State at delivery
Yes
W, VA, var, PF, DF, THD, cos φ
varh, VAh, Wh
Up to 50th order
up to several days
4,096
Yes
yes, with display of phase order for three-phase systems
Yes
6 RPM to 120 kRPM ± (0.5 %)
-200 °C to +850 °C ± (1 % + 10 cts)
0 Ω to 2,000 Ω ± (0.5 % + 2 Ω)
6 AA batteries
840 g (with batteries)
Yes
23 °C ± 3 K
45 % to 75 %
IP54
Yes
IEC 61010-1, 600 V- cat. III
Rechargeable batteries, battery life up to 40 hours
880 g (with rechargeable batteries)
211 x 108 x 60 mm
Delivered with 6 AA batteries installed, 1 red banana lead
(straight-straight), 1 black banana lead (straight-straight),
2 x 4 mm test probes (1 red, 1 black), 2 crocodile clips
(1 red, 1 black), 1 USB optical cable, PAT software
Accessories
For DataView® software
and E3N clamp, see
pages 27 and 28
Delivered with a carrying bag, 6 x 1.2 V rechargeable batteries
installed, 1 red banana lead (straight-straight), 1 black
banana lead (straight-straight), 2 x 4 mm test probes
(1 red, 1 black), 2 crocodile clips (1 red, 1 black),
1 mains adapter, USB optical cable, PAT software
Red and black 4 mm test probes. . . . . . . . . . . . . . . >
Red and black crocodile clips. . . . . . . . . . . . . . . . . . >
Red and black 4 mm banana/banana leads. . . . . . . >
MN93A BK clamp. . . . . . . . . . . . . . . . . . . . . . . . . . . >
MN93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
AmpFlex® A 193 450 mm BK. . . . . . . . . . . . . . . . . . >
AmpFlex® A 193 800 mm BK. . . . . . . . . . . . . . . . . . >
PAC93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . >
C193 BK clamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Mains adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
RPM probes C.A 1711 . . . . . . . . . . . . . . . . . . . . . . . >
Temperature probes. . . . . . . . . . . . . . . . . . . . . . . . . >
E3N clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
P01101855
P01101848
P01295091
P01120434B
P01120425B
P01120526B
P01120531B
P01120079B
P01120323B
P01160640
P01102082
HX0091
P01120047
29
Power, Energy, Disturbances
Power and Energy Loggers
>Single-phase, split-phase and three-phase installations
>Installation without cutting off the mains power supply
>Harmonic analysis up to the 50th order
>Bluetooth, Ethernet and USB Communication
>Automatic recognition of the sensors connected
>Recording on SD card
1000 V CAT III
PEL102
Display
Installation types
With triple digital display
Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations
Number of channels
3 Voltage inputs / 3 Current inputs (neutral current calculated)
Measurements
Network frequency
DC, 50 Hz, 60 Hz & 400 Hz
Voltage (Measurement ranges/ Best accuracy)
10.00 to 1,000 V AC/DC
/
+/- 0.2 % + 0.5 V
100.0 mA to 0.00 kAAC
/
+/- 1.2 % + 70 mA
2.000 to 240.0 AAC / +/- 1.2 % + 1 A
0.005 AAC to 5.000 AAC /
0.100 AAC to 120.0 AAC / +/- 1.2 % + 2 mA
3.000 A to 1,200 AAC / +/- 0.5 %
MN93
MN93A
Current
PEL103
Without
C193
A193 & MA193
PAC93
/
10.00 A to 1,000 AAC
E3N
50.00 mA to 10.00 AAC/DC
/
10.00 A to 1,400 ADC
/
+/- 1.7 % + 1 A
100.0 mA to 100.0 AAC/DC
/
+/- 3.2 % + 70 mA
Calculated measurements
Ratios
Up to 650,000 V / up to 25,000 A
Power
10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA
Energy
Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018 )
Phase
cos φ, tan Φ, PF
Harmonics
Up to 50th order
Additional functions
Phase order
Yes
Min / Max
Yes
Mounting
Magnet, hook
Recording
Sampling / Acquisition rate / Aggregation
128 samples/period - 1 measurement/s – from 1 min to 60 min
Storage
SD Card, 2 GB (SD-HC Card up to 32 GB)
Communication
Ethernet & Bluetooth
Power supply
110 V - 250 V (+10 %, -15 %) @ 50-60 Hz & 400 Hz
Safety
IEC 61010 600 V CAT IV – 1,000 V CAT III
Mechanical specifications
Dimensions
256 x 125 x 37 mm without sensor
Weight
900 g
Casing
References
Accessories
30
950 g
IP54 , UL (pending)
• PEL102 Logger without current sensors> P01157152
• PEL103 Logger without current sensors> P01157153
DataVIEW® software >
Bag No 23
>
Leads/clamps kit >
Set of id. rings/inserts >
5 A box >
MN93 clamp
>
MN93A clamp
>
P01102095
P01298078
P01295476
P01102080
P01101959
P01120425B
P01120434B
C193 clamp
>
PAC93 clamp
>
AmpFlex®
A193-450 mm clamp >
AmpFlex®
A193-800 mm clamp >
P01120323B
P01120079B
P01120526B
P01120531B
Mini-AmpFlex®
MA193, 200 mm
E3N clamp
E3N adapter
MultiFIX
Mains power cable
>
>
>
>
>
P01120580
P01120043A
P01120081
P01102100Z
P01295174
Environmental Measurements
Non-contact
thermometers
C.A 871
C.A 879
C.A 1864
P01651302Z
P01651805Z
P01651813
8/1
12/1
30/1
For both industry and self-employed electricians
Reference
Distance/spot ratio
Emissivity
0.95
Measurement range
-50 to +550 °C
-50 to +1,000 °C
0.1 °C to 100 °C, 1 °C above
Accuracy
Functions
50/1
0.1 to 1
-40 to +538 °C
Resolution
C.A 1866
Measurements
up to 1,000 °C
P01651814
Precise laser sighting
± 2.5 % ± 2 °C
0.1 °C
± 1.5 % ± 2 °C
1.5 % ± 2 °C
Laser sight
Continuous measurement
Max. value
yes
Min. value
yes
Average
yes
Alarms
yes
yes
yes
Auto hold
yes
Choice of measurement unit
°C or °F
Display
2,000 cts
20,000 cts
Backlighting
Dimensions
yes
160 x 82 x 41.5 mm
230 x 100 x 56 mm
180 g
290 g
Weight
State at delivery
230 x 100 x 56 mm
290 g
Delivered with 9 V battery, wrist strap, soft case
and operating manual
Delivered with 9 V battery + soft case
Tachometers
RPM
function
m/min
function
Hz function
ms function
Ratio
function
Counting
function
Range
Accuracy
C.A 1725
C.A 1727
P01174810
P01174830
10-4 R ± 6 cts
Range
0.6 to 60,000 m/min
10-4 R ± 1 increment
Range
0 .1 to 10,000 Hz
Accuracy
4 x 10-5 R ± 4 cts
Range
0.1 t o 10,0 00 ms
Accuracy
Range
Accuracy
10 to 10,000 %
0.1 % to 1 %
Reference
0 to 99,999 events
Accuracy
± 1 event
Min., Max., HOLD, Smoothing
High and low alarms
Storage
State at
delivery
Dimensions / Weight
P01174902
P01174903
P01101797
P01101785
P01174835
P01295293
C.A 811
10-4 R ±5 cts
4,000 alarms
delivered in a hard case with
1 FRB F connector, a 9 V battery,
1 set of 15 reflective strips
(length: 0.1 m), 1 operating manual on
CD and 1 printed quick startup guide
>
>
>
>
>
>
Mechanical accessories kit
End fittings (set of 3)
Reflective strips (15 x 0.1 m strips)
FRB F connector
TACHOGRAPH software on CD-Rom
Cable: USB-A to USB-B
Lightmeters
Range
Functions
Tachometers accesories
•
•
•
•
•
•
6 to 100,000 RPM
Accuracy
• Measurement up to 100,000 RPM
• Contact and non-contact measurement
• Wide range of functions available: rotation speed, linear,
counting, frequency, period
• Possibility of programming and storage capacity for the C.A 1727
• USB link for processing the records on PC for the C.A 1727
delivered in a hard case with 1 FRB F
connector, a 9 V battery,1 set of
15 reflective strips (length: 0.1 m),
1 operating manual, TACHOGRAPH
software on CD-Rom and a printed
quick startup guide
21 x 72 x 47 mm / 250 g
Measurement range
Measures up to
200,000 lux
P01172201Z
P01172401Z
4 ranges:
0 to 20,000 lux
5 ranges:
0 to 200,000 lux
Accuracy
(incandescent lamp)
Accuracy
(other light sources)
± 3 % + 10 cts
18 % + 2 cts
I.C.I. spectral correction
Incidence correction
Max. value
Choice of measurement
unit
Display
Dimensions
Weight
State at delivery
C.A 813
Measures up
to 20,000 lux
11 % + 2 cts
yes
yes
yes
yes
lux or Fc
2,000 counts
173 x 60.5 x 38 mm
214 g
223 g
with shockproof protective sheath
31
Earth Clamps
and Loop Testers
IP
40
600 V CAT IV
C.A 6416
Loop ohmmeter
1,500-count display
C.A 6417
Measurement ranges (Ω) / Resolution (Ω) / Accuracy
0.010 to 0.099 / 0.001 / ±1.5 % ±0.01
0.10 to 0.99 / 0.01 / ±1.5 % ±2 r
1.0 to 49.9 / 0.1 / ±1.5 % ±r
50.0 to 99.5 / 0.5 / ±2 % ±r
100 to 199 / 1 / ±3 % ±r
200 to 395 / 5 / ±5 % ±r
400 to 590 / 10 / ±10 % ±r
600 to 1150 / 50 / Approx. 20 %
1200 to 1500 / 50 / Approx. 25 %
Measurement frequency: 2083 Hz /
Transposition frequency: 50, 60, 128 or 2083 Hz
Frequency
Loop inductance measurement
Measurement ranges (μH) / Resolution (μH) / Accuracy
10 to 100 / 1 / ±5 %±r
100 to 500 / 1 / ±3 %±r
Contact voltage
Measurement ranges (V) / Resolution (V)
0.1 to 4.9 / 0.1
5.0 to 49.5 / 0.5
50.0 to 75.0 / 1
Ammeter
Measurement ranges (A) / Resolution (A) /
Accuracy
4,000-count display
Measurement ranges (A) / Resolution (A) / Accuracy
0.200 to 0.999 mA / 1 μA / ±2 % ±50 μA
1.000 to 2.990 mA - 3.00 to 9.99 mA / 10 μA / ±2 % ±50 μA
10.00 to 29.90 mA - 30.0 to 99.9 mA / 100 μA / ±2 %±r
100.0 to 299.0 mA - 0.300 to 0.990 A / 1 mA / ±2 %±r
Setup
Modes
Alarms
Buzzer
HOLD
Automatic power-off
General specifications
Display
Max. clamping diameter
Storage
Communication
Power supply
Battery life
Calibration
Electrical safety
Protection
Dimensions
Weight
1.000 to 2.990 A - 3.00 to 39.99 A / 10 mA / ±2 %±r
Standard or advanced
Configurable on Z, V and A
Active
Manual or automatic PRE-HOLD
Active / Inactive
152-segment OLED. Active area 48 x 39 mm
Ø 35 mm
300 time/date-stamped measurements
2,000 time/date-stamped measurements
Bluetooth Class 2
4 x 1.5 V LR6 (AA) alkaline batteries or 4 x Ni-MH batteries
1440 x 30-second measurements
Automatic at start-up
IEC 61010 600 V CAT IV
IP40
55 x 95 x 262 mm
Approx. 935 g with batteries
State at delivery
• C.A 6416: 1 clamp delivered in a hard case with
4 x 1.5 V batteries, 1 CD-Rom containing the
operating manual in 5 languages
• C.A 6417: 1 clamp delivered in a hard case with
4 x 1.5 V batteries, 1 CD-Rom containing the
operating manual in 5 languages and the GTT
software with simplified driver
References and accessories
• C.A 6416. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > P01122015
• C.A 6417. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > P01122016
•
•
•
•
L1 calibration loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
C
DataView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Bluetooth USB modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Hard case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
P01122301
P01102095
P01102112
P01298080
23
Electrical Testing and Safety
Micro-ohmmeters
C.A 6240
C.A 6250
P01143200
P01143201
Low-level resistance measurements
Reference
Measurement method
Resistance
Resolution
Accuracy
Current
Current inversion
Measurement mode
Temperature
compensation
Power supply
Electrical safety
Dimensions
Weight
State at delivery
4-wire method
400 μΩ to 400.0 Ω
1 μΩ to 2,500 Ω
1 µΩ
0.1 µΩ
0.25 %
10 mA to 10 A
0.05 %
1 mA to 10 A
No, but automatic compensation
of eddy currents
Yes
Inductive, non-inductive, non-inductive with automatic triggering
no
Manual or with Pt 100 probe
NiMH rechargeable battery
IEC 61010-1 / Cat III 50 V
270 x 250 x 180 mm
4.5 kg
4 kg
Mains power cable / leads with Kelvin clamps / software /
optical /USB communication cable / bag
Electrical equipment tester
DTR 8510
Range of ratios (VT)
Accuracy (VT)
Range of ratios (TC)
Accuracy (TC)
Excitation signal
Excitation current display
Excitation frequency
Display
Available languages
Measurement method
Power supply
Battery life
Battery charger
Charging time
Storage
Date / time
Communication
Software
Dimensions / Weight
Connection
Leads
Casing
Vibrations
Shocks
Falls
Protection rating
Safety
State at delivery
24
Digital ratiometer for transformers
Automatic: 0.8000 to 8,000:1
Range of ratios
Accuracy (% of reading)
0.8000 to 9.9999
± 0.2 %
10.000 to 999.99
± 0.1 %
1000.0 to 4999.9
± 0.2 %
5000.0 to 8000.0
± 0.25 %
Autoranging: 0.8000 to 1000.0
± 0.5 % of reading
VT mode: 32 Vrms max
CT mode: Auto level 0 to 1 A, 0.1 to 4.5 Vrms
Range: 0 to 1,000 mA; Accuracy: ± (2 % R + 2 mA)
70 Hz
Alphanumeric LCD, 2 lines of 16 characters with adjustment of contrast and
backlighting. Easy to read in both daytime and nighttime conditions
French, English, Spanish, Italian, German, Portuguese
According to IEEE Std C57, 12.90™ -2006 standard
Two rechargeable batteries: 12 V, NiMH, 1650 mAH
Up to 10 hrs in continuous operation, low-battery warning
Universal input (90 to 264 Vrms), smart charger
< 4 hours for full charge
10,000 tests
Power supplied by dedicated battery, real-time clock
USB 2.0, optical isolation, 115.2 kB
Delivered with DataView® analytical software
272 x 248 x 130 mm / 3.7 kg
XLR connectors
Screened H and X leads, length 4.6 m (15 ft),equipped with colour-coded
crocodile clips
Rugged polypropylene casing, UL 90 V0
IEC 68-2-6 (1.5 mm at 55 Hz)
IEC 68-2-27 (30 G)
IEC 68-2-32 (1 m)
IP 40 with cover open as per EN 60529
IP 53 with cover closed as per EN 60529
EN 61010-1, 50 V CAT IV; pollution degree 2
Delivered with a carrying bag containing 1 set of 4.6 m leads with crocodile
clips, 1 external battery charger with mains power cable, 1 USB cable,
1 NiMH battery datasheet, 1 operating manual and DataView software on
CD-Rom
Power, Energy, Disturbances
Symptoms of disturbances on an electricity network
Qualimetry is a major focus for many companies, not least because of its financial benefits.
Before raising the issue of a diagnosis of their electrical system, it is worth knowing the different symptoms,
listed in the table below, which indicate faults in an installation.
DC
co
mp
on
Th
en
r
t
e
un e-p
ba
h
a
lan se
ce
Fre
va que
ria nc
tio y
ns
Ex
po cess
we re
ac
r
tiv
EM
e
C
SYMPTOMS
Flic
ke
r
Bro
wn
-ou
ts
Un
de
r-v
olt
Ov
ag
ere
v
Atm olta
g
su osp e
rge he
ric
s
Ha
rm
on
ics
Int
erha
rm
Ho
on
ics
ha morm po
on lar
ics
Mi
cro
-ou
tag
Sh
ort
es
po
we
Lo
rc
lon ng a
uts
g o nd
uta ver
ge y
HF
s
sp
ike
s
Po
w
su er
rge
s
POSSIBLE
ORIGINS
Processes operate
erratically
Random stoppages
of process equipment
Process stoppages
Damage to equipment
Overheating and noise
from equipment
Malfunctions
on motors
Abnormal vibration
and noise on motors
Stoppages of motors
Malfunction
of the electronic
Malfunction
of electronics
Erratic operation
of protection systems
Untimely tripping
of protection systems
Non-operation
of protection systems
Triggering of arcs
Problems with monitors
Problems
with radio-communications
Computer
and telecom interference
Destruction
of PCBs
Destruction
of computer hardware
Flicker of lighting
Electrocution
Fire of electrical origin
The standards
EN 50160
IEC 61000-4-30
IEC 61000-4-7
Defines the method for
measuring harmonics
and interharmonics
IEC 61000-4-15
Defines the flicker measurement
method including:
• Pst short-term flicker indicator:
Quantitative evaluation of the flicker
over a 10-minute period.
• Plt long-term flicker indicator:
Quantitative evaluation of the flicker
➜
Defines the methods
and accuracies for
the power quality
measurements listed in
the EN 50160 standard
(rms voltage, outage,
voltage dips and swells,
unbalance,...).
➜
Defines the
measurements
required to qualify
the voltage delivered
by the electrical grid:
rms voltage, outages,
voltage dips, swells,
flicker, frequency,
harmonics (up to the
40th order) and
three-phase system
unbalance.
over a 2-hour period, using
12 successive short-term flicker
(Pst) values.
25
Power, Energy, Disturbances
Electrical energy analysers for three-phase networks
CAT
IV
•5 voltage inputs and 4 current inputs
•10-minute Inrush mode
•Calculation of distorting power
•IP67: all-terrain model available
IEC 61000-4-30
IEC 61010
1000 V CAT III
600 V CAT IV
IP
67
IEC 61000-4-30
C.A 8331
Number of channels
Number of inputs
Voltage (TRMS AC+DC)
Current (TRMS AC+DC) Frequency
Power values
Energy values
Harmonics
3U / 4I
4V / 3I
Voltage ratio
THD
Expert mode
-
Min/Max
of a selection of parameters at max. sampling rate
4 hrs to 2 weeks
Alarm
Peak
Vectorial representation
Display
Capture of screens and curves
Electrical safety
Protection
Languages
Battery life
Communication interface
Power supply
Dimensions
Weight
Warranty
26
C.A 8336
2 V to 1,000 V
Up to 500 kV
C.A 8435
4U / 4I
5V / 4I
MN93 : 2 to 200 Aac ; MN93A : 0,005 Aac to 100 Aac
MN clamps
C193 clamp
AmpFlex® or MA clamps
PAC93 clamp
E3N clamp
Current ratio
Transients
Flicker (Pst and Plt)
Inrush mode
Unbalance
Recording
IEC 61000-4-30
C.A 8333
12
—
1 A to 1 000 Aac
100 mA to 10 000 Aac
30 A to 6 500 Aac
1 A to 1 000 Aac+dc
50 mA to 10 Aac/dc – 100 mA to 100 Aac/dc
Up to 60 kA
40 Hz to 69 Hz
W, VA, var, VAD, PF, DPF, cos φ, tan φ
Wh, varh, VAh, VADh
Yes
Yes, orders 0 to 50, phase
Yes
50
210
Yes
Yes over 4 periods
Yes > 10 minutes
Yes
Yes
A few days
2 weeks to several years
to several weeks
4,000 of 10
10,000 of 40 different types
different types
Yes
Automatic
TFT colour ¼ VGA screen, 320 x 240, diagonal 148 mm
12
50
IEC 61010 1,000 V CAT III / 600 V CAT IV
IP53 / IK08
IP67
More than 27
Up to 13 hours
USB
9.6 V NiMH rechargeable battery or mains power supply
Yes with DataView®
Yes with DataView® software
—
software
240 x 180 x 55 mm
270 x 250 x 180 mm
1.9 kg
3.7 kg
3 years
State at delivery
C.A 8336 • C.A 8333 • C.A 8331 – Models without sensors
Qualistar+ analyser delivered with a bag for accessories, 5 x 4 mm banana voltage leads 3 m long,
5 crocodile clips, 12-colour identification kit for the leads and inputs, anti-scratch screen-protection film
(mounted), USB cable, mains power cable, mains power pack, safety datasheet, 1 CD containing multilanguage operating manual and 1 CD containing PC software for data recovery (Power Analyzer Transfer).
C.A 8435 AMP450
Delivered with bag no. 22, USB cable, IP67 mains power cable, 4 AmpFlex® 450 IP67 A196 current
sensors, 5 x IP67 BB196 black banana leads, 5 lockable crocodile clips, 12-colour identification kit for the
leads and inputs, anti-scratch screen-protection film (mounted), USB cable, mains power cable, mains
power pack, safety datasheet, 1 CD containing multi-language operating manual and 1 CD containing PC
software for data recovery (Power Analyzer Transfer).
References
• C.A 8336 alone . . . . . . . . . . . . . . . . . > P01160591
• C.A 8333 alone. . . . . . . . . . . . . . . . . . > P01160541
• C.A 8331 alone. . . . . . . . . . . . . . . . . . > P01160511
• C.A 8435 alone. . . . . . . . . . . . . . . . . . > P01160585
• C.A 8435 AmpFlex® 450 mm. . . . . . . > P01160587
Software
The measurements performed with the Qualistar models can be processed using two software products:
(standard) and
(option).
Configuration of the instrument: setup, recording, alarms
Real-time display
Processing of recorded data and alarms
Transfer of printouts of screenshots and transients
Data export into Excel spreadsheet
Data export in graph form in Windows™











The easy-to-use
software automatically recognizes the
instrument connected to the PC and opens the corresponding menu.
Users have direct access to:
database management
management of reports according
to the voltage quality standards




 

















 
 

   

 

 






 
  
 
 
   

    

 
 
   
 
 
   
 
   






















•
•
•
•
is compatible with other Chauvin Arnoux® products:
Qualistar+ power analysers
C.A 8220 & C.A 8230 power analysers
F400 and F600 multimeter clamps
and other measuring instruments
Minimum operating system required:
Windows® 2000, Windows® XP, Windows® Vista, Windows® 7 and 8.
Reference






 





  




 


 

 
 

 



     









 




     



     




 









     









 




     





     




 









     









 


   


 













































 
 
    
    
    
    
    
    
    
    
    
    
    
    
    
 






• Dataview® software . . . . . . . . . . . . . . > P01102095
27
Power, Energy, Disturbances
Essailec accessory for all the Qualistar + models
A lead with an ESSAILEC plug can be used to perform tests without
disturbing or interrupting the power supply circuit on meters and
protection relays installed in the secondary circuits of current or voltage
transformers. The main advantage is the speed and simplicity of
measurement with maximum user safety.
Accessory for electrical cabinets equipped with Essailec connectors.
Clamps for Qualistar +
Model
Measurement range
Clamping Ø /
length
IEC 61010
MN93
MN 93A
MA193
PAC93
A196-450
A193-450
A193-800
C193
E3N
0,5 to
200 Aac
0,005 Aac
to 100 Aac
100 mA to
10k Aac
1 A to 1000 Aac
1 A to 1300
Adc
100 mA
to 10 k Aac
100 mA to
10k Aac
1 A to
1000 Aac
50 mA to
10 Aac/dc
100 mA
to 100 Aac/dc
20 mm
20 mm
70 mm /
220 mm
1 x Ø 39 mm
2 x Ø 25 mm
Ø 450 mm
140 mm
Ø 800 mm
250 mm
52 mm
11,8 mm
600 V CAT
III / 300 V
CAT IV
600 V CAT III /
300 V CAT IV
1000 V CAT III
/ 600 V CAT IV
600 V CAT III /
300 V CAT IV
1000 V CAT
III / 600 V
CAT IV
1000 V CAT III
600 V CAT IV
/ 600 V CAT IV
600 V CAT III /
300 V CAT IV
Available accessories - References to order
ESSAILEC unit.................................................. >
MN93 clamp...................................................... >
MN93A clamp.................................................... >
MiniFlex® MA193, 200 mm............................... >
PAC93 clamp.................................................... >
AmpFlex® A196 450 mm IP67.......................... >
AmpFlex® clamp, A193 450 mm....................... >
AmpFlex® clamp, A193 800 mm....................... >
C193 clamp....................................................... >
E3N clamp......................................................... >
E3N adapter...................................................... >
E3N mains power pack..................................... >
Battery pack...................................................... >
Qualistar screen film......................................... >
Set of rings-inserts............................................ >
28
P01102131
P01120425B
P01120434B
P01120580
P01120079B
P01120552
P01120526B
P01120531B
P01120323B
P01120043A
P01102081
P01120047
P01296024
P01102059
P01102080
Set of 5 x IP67 banana leads
3 m long (BB196).............................................. > P01295479
Bag no. 21......................................................... > P01298055
Bag no. 22......................................................... > P01298056
USB-A USB-B cable.......................................... > P01295293
5 A unit.............................................................. > P01101959
Lockable crocodile clips (x 5)............................ > P01102099
Kit comprising banana leads (x 5), crocodile clips (x 5)
and 1 set of coloured rings................................ > P01295483
Kit comprising banana leads (x 4), crocodile clips (x 5)
and 1 set of coloured rings................................ > P01295476
Set of plugs (C.A 8435)..................................... > P01102117
Mains power pack (C.A 8335)........................... > P01102057
IP67 mains power cable (C.A 8435)................. > P01295477
Power analysers for three-phase electrical networks
CAT
III
Reference
Voltage
AC current
DC current
C.A 8220
C.A 8230
Specially designed for motor maintenance
Access to all the measurements simultaneously
Low-resistance and high-current measurements
Large colour screen
Intuitive use
Excellent price-quality ratio
Recording
Alarms
P01160620
Accuracy
Accuracy
Accuracy
Values
Fundamental frequency
Display
P01160630
6 Vrms to 600 Vrms AC+DC
± (0.5 % + 2 cts)
5 mA to 6,500 A
± (0.5 % + 1 ct)
1 A to 1,400 A
± (1% + 1 A)
Min, max, avg. Peak (+ and -), crest factor
40 Hz to 70 Hz
Backlit LCD with 3 displays of 173 segments
VGA colour LCD (320 x 240)
Single-phase and
balanced three-phase
Power measurements
Energy
Harmonics
Recording
Alarms
PST flicker
Functions
Phase rotation
Motor inrush
current display
Motor rotation speed
Temperature (Pt 100)
Resistance (winding)
Measurement storage
Use
Ambient temperature
Relative humidity
Protection rating
USB optical port
Safety
Power supply
Weight
Dimensions
State at delivery
Yes
W, VA, var, PF, DF, THD, cos φ
varh, VAh, Wh
Up to 50th order
up to several days
4,096
Yes
yes, with display of phase order for three-phase systems
Yes
6 RPM to 120 kRPM ± (0.5 %)
-200 °C to +850 °C ± (1 % + 10 cts)
0 Ω to 2,000 Ω ± (0.5 % + 2 Ω)
6 AA batteries
840 g (with batteries)
Yes
23 °C ± 3 K
45 % to 75 %
IP54
Yes
IEC 61010-1, 600 V- cat. III
Rechargeable batteries, battery life up to 40 hours
880 g (with rechargeable batteries)
211 x 108 x 60 mm
Delivered with 6 AA batteries installed, 1 red banana lead
(straight-straight), 1 black banana lead (straight-straight),
2 x 4 mm test probes (1 red, 1 black), 2 crocodile clips
(1 red, 1 black), 1 USB optical cable, PAT software
Accessories
For DataView® software
and E3N clamp, see
pages 27 and 28
Delivered with a carrying bag, 6 x 1.2 V rechargeable batteries
installed, 1 red banana lead (straight-straight), 1 black
banana lead (straight-straight), 2 x 4 mm test probes
(1 red, 1 black), 2 crocodile clips (1 red, 1 black),
1 mains adapter, USB optical cable, PAT software
Red and black 4 mm test probes. . . . . . . . . . . . . . . >
Red and black crocodile clips. . . . . . . . . . . . . . . . . . >
Red and black 4 mm banana/banana leads. . . . . . . >
MN93A BK clamp. . . . . . . . . . . . . . . . . . . . . . . . . . . >
MN93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
AmpFlex® A 193 450 mm BK. . . . . . . . . . . . . . . . . . >
AmpFlex® A 193 800 mm BK. . . . . . . . . . . . . . . . . . >
PAC93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . >
C193 BK clamp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
Mains adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
RPM probes C.A 1711 . . . . . . . . . . . . . . . . . . . . . . . >
Temperature probes. . . . . . . . . . . . . . . . . . . . . . . . . >
E3N clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >
P01101855
P01101848
P01295091
P01120434B
P01120425B
P01120526B
P01120531B
P01120079B
P01120323B
P01160640
P01102082
HX0091
P01120047
29
Power, Energy, Disturbances
Power and Energy Loggers
>Single-phase, split-phase and three-phase installations
>Installation without cutting off the mains power supply
>Harmonic analysis up to the 50th order
>Bluetooth, Ethernet and USB Communication
>Automatic recognition of the sensors connected
>Recording on SD card
1000 V CAT III
PEL102
Display
Installation types
With triple digital display
Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations
Number of channels
3 Voltage inputs / 3 Current inputs (neutral current calculated)
Measurements
Network frequency
DC, 50 Hz, 60 Hz & 400 Hz
Voltage (Measurement ranges/ Best accuracy)
10.00 to 1,000 V AC/DC
/
+/- 0.2 % + 0.5 V
100.0 mA to 0.00 kAAC
/
+/- 1.2 % + 70 mA
2.000 to 240.0 AAC / +/- 1.2 % + 1 A
0.005 AAC to 5.000 AAC /
0.100 AAC to 120.0 AAC / +/- 1.2 % + 2 mA
3.000 A to 1,200 AAC / +/- 0.5 %
MN93
MN93A
Current
PEL103
Without
C193
A193 & MA193
PAC93
/
10.00 A to 1,000 AAC
E3N
50.00 mA to 10.00 AAC/DC
/
10.00 A to 1,400 ADC
/
+/- 1.7 % + 1 A
100.0 mA to 100.0 AAC/DC
/
+/- 3.2 % + 70 mA
Calculated measurements
Ratios
Up to 650,000 V / up to 25,000 A
Power
10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA
Energy
Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018 )
Phase
cos φ, tan Φ, PF
Harmonics
Up to 50th order
Additional functions
Phase order
Yes
Min / Max
Yes
Mounting
Magnet, hook
Recording
Sampling / Acquisition rate / Aggregation
128 samples/period - 1 measurement/s – from 1 min to 60 min
Storage
SD Card, 2 GB (SD-HC Card up to 32 GB)
Communication
Ethernet & Bluetooth
Power supply
110 V - 250 V (+10 %, -15 %) @ 50-60 Hz & 400 Hz
Safety
IEC 61010 600 V CAT IV – 1,000 V CAT III
Mechanical specifications
Dimensions
256 x 125 x 37 mm without sensor
Weight
900 g
Casing
References
Accessories
30
950 g
IP54 , UL (pending)
• PEL102 Logger without current sensors> P01157152
• PEL103 Logger without current sensors> P01157153
DataVIEW® software >
Bag No 23
>
Leads/clamps kit >
Set of id. rings/inserts >
5 A box >
MN93 clamp
>
MN93A clamp
>
P01102095
P01298078
P01295476
P01102080
P01101959
P01120425B
P01120434B
C193 clamp
>
PAC93 clamp
>
AmpFlex®
A193-450 mm clamp >
AmpFlex®
A193-800 mm clamp >
P01120323B
P01120079B
P01120526B
P01120531B
Mini-AmpFlex®
MA193, 200 mm
E3N clamp
E3N adapter
MultiFIX
Mains power cable
>
>
>
>
>
P01120580
P01120043A
P01120081
P01102100Z
P01295174
Environmental Measurements
Non-contact
thermometers
C.A 871
C.A 879
C.A 1864
P01651302Z
P01651805Z
P01651813
8/1
12/1
30/1
For both industry and self-employed electricians
Reference
Distance/spot ratio
Emissivity
0.95
Measurement range
-50 to +550 °C
-50 to +1,000 °C
0.1 °C to 100 °C, 1 °C above
Accuracy
Functions
50/1
0.1 to 1
-40 to +538 °C
Resolution
C.A 1866
Measurements
up to 1,000 °C
P01651814
Precise laser sighting
± 2.5 % ± 2 °C
0.1 °C
± 1.5 % ± 2 °C
1.5 % ± 2 °C
Laser sight
Continuous measurement
Max. value
yes
Min. value
yes
Average
yes
Alarms
yes
yes
yes
Auto hold
yes
Choice of measurement unit
°C or °F
Display
2,000 cts
20,000 cts
Backlighting
Dimensions
yes
160 x 82 x 41.5 mm
230 x 100 x 56 mm
180 g
290 g
Weight
State at delivery
230 x 100 x 56 mm
290 g
Delivered with 9 V battery, wrist strap, soft case
and operating manual
Delivered with 9 V battery + soft case
Tachometers
RPM
function
m/min
function
Hz function
ms function
Ratio
function
Counting
function
Range
Accuracy
C.A 1725
C.A 1727
P01174810
P01174830
10-4 R ± 6 cts
Range
0.6 to 60,000 m/min
10-4 R ± 1 increment
Range
0 .1 to 10,000 Hz
Accuracy
4 x 10-5 R ± 4 cts
Range
0.1 t o 10,0 00 ms
Accuracy
Range
Accuracy
10 to 10,000 %
0.1 % to 1 %
Reference
0 to 99,999 events
Accuracy
± 1 event
Min., Max., HOLD, Smoothing
High and low alarms
Storage
State at
delivery
Dimensions / Weight
P01174902
P01174903
P01101797
P01101785
P01174835
P01295293
C.A 811
10-4 R ±5 cts
4,000 alarms
delivered in a hard case with
1 FRB F connector, a 9 V battery,
1 set of 15 reflective strips
(length: 0.1 m), 1 operating manual on
CD and 1 printed quick startup guide
>
>
>
>
>
>
Mechanical accessories kit
End fittings (set of 3)
Reflective strips (15 x 0.1 m strips)
FRB F connector
TACHOGRAPH software on CD-Rom
Cable: USB-A to USB-B
Lightmeters
Range
Functions
Tachometers accesories
•
•
•
•
•
•
6 to 100,000 RPM
Accuracy
• Measurement up to 100,000 RPM
• Contact and non-contact measurement
• Wide range of functions available: rotation speed, linear,
counting, frequency, period
• Possibility of programming and storage capacity for the C.A 1727
• USB link for processing the records on PC for the C.A 1727
delivered in a hard case with 1 FRB F
connector, a 9 V battery,1 set of
15 reflective strips (length: 0.1 m),
1 operating manual, TACHOGRAPH
software on CD-Rom and a printed
quick startup guide
21 x 72 x 47 mm / 250 g
Measurement range
Measures up to
200,000 lux
P01172201Z
P01172401Z
4 ranges:
0 to 20,000 lux
5 ranges:
0 to 200,000 lux
Accuracy
(incandescent lamp)
Accuracy
(other light sources)
± 3 % + 10 cts
18 % + 2 cts
I.C.I. spectral correction
Incidence correction
Max. value
Choice of measurement
unit
Display
Dimensions
Weight
State at delivery
C.A 813
Measures up
to 20,000 lux
11 % + 2 cts
yes
yes
yes
yes
lux or Fc
2,000 counts
173 x 60.5 x 38 mm
214 g
223 g
with shockproof protective sheath
31
Current measurement
AC and AC/DC current measurement
35 mm
MINI 01
MINI 02
MINI 03
11
5
MINI 05
m
m
35 mm
MINI 09
MN08
135 m
m
18.5 mm
AC
1 to 100 A
5 mA to 10 A
1 to 100 A
1 to 150 A
0.5 to 240 A
0.5 to 240 A
MN11
0.5 to 240 A
MN12
0.5 to 240 A
MN13
0.5 to 240 A
MN14
0.5 to 240 A
MN39
0.1 to 24 A
0.5 to 240 A
10 mA to 2.4 A
100 mA to 240 A
0.15 A AC
0.1 V AC
10 V A AC
0.1 V AC
•
•
•
•
•
•
•
15 V DC
0.2 A AC
0.2 A AC
0.2 A AC
2 V AC
2 V AC
0.2 V AC
66 mm
31 mm
216
mm
310 m
m
48 mm
111
mm
310 mm
11
1m
m
15
mm
C173
1 mA to 1.2 A
0.01 to 12 A
0.1 to 120 A
1 to 1,200 A
D30CN
1 to 3,600 A
D36N
1 to 3,600 A
K1
1 mA to 4.5 A DC
1 mA to 3 A RMS
1 mA to 4.5 A peak
K2
100 µA to 450 mA DC
100 µA to 300 mA
RMS
100 µA to 450 A peak
67 mm
E1N
231
mm
AC/
DC
25 mm
C148
1 to 300 A
1 to 600 A
1 to 1,200 A
E6N
20 mm
32
0.05 to 2 A DC
0.05 to 1.5 A AC
0.5 to 150 A AC/DC
5 mA to 2 A DC
5 mA to 1.5 A AC
20 mA to 80 A AC/DC
• Typical accuracy
(frequency in Hz)
• Bandwidth
(low phase shift)
• Automatic DC zero
• Output protected
against overvoltage
(input/output)
• Transformation ratio
(oscilloscopes)
• BNC connector
• Power measurement
•
48 Hz...10 Hz ≤ 1 %
P01051102Z
≤ 2%
P01051103Z
≤ 3%
1 mA/1 mV
1 A/1 mV
48 Hz... 500 Hz ≤ 2%
1 A/100 mV
≤ 4%
P01051105Z
P01051109Z
1,000/1
40 Hz... 10 kHz ≤ 1%
P01120401
1,000/1
40 Hz... 10 kHz ≤ 1%
P01120402
40 Hz... 10 kHz ≤ 2%
P01120404
40 Hz... 10 kHz ≤ 1%
P01120405
1,000/1
•
•
1A/10mV
1A/10mV
•
40 Hz... 10 kHz ≤ 1%
P01120406
1A/1mV
40 Hz... 10 kHz ≤ 1%
P01120416
P01120408
•
2 V AC
2 V AC
•
1mA/1mV
1A/10mV
40 Hz... 10 kHz
≤ 1%
≤ 2%
P01120421
20 V DC(2)
•
1A/100mV
40 Hz... 10 kHz ≤ 2%
P01120415
•
1,000/1
48 Hz... 1 kHz
P01120001A
0.5 A AC
20 mm
C122
48 Hz... 500 Hz ≤ 2.5 % P01051101Z
40 Hz... 10 kHz ≤ 1%
•
1 A to 1,200 A
1 A / 1 mV
•
•
1A/100mV
1A/10mV
4 A to 600 A
0.1 A to 1,200 A
•
•
1,000/1
To order
•
Y1N
C103
•
•
1,000/1
2 V AC
2 V AC
•
0.1 A to 1,200 A
•
•
•
Specific features
•
0.5 to 240 A
C100
•
• Female sockets ø 4 mm
• Leads
+ safety plug ø 4 mm
• Voltage
0.15 A AC
•
MN89
213 mm
• Current
•
•
•
--- DC
• ...
Output / Connections
• ~ AC
• High current
• Medium current
2 to 150 A
50 mA to 100 A
MN09
MN73
51 mm
• Low current
Model
Series
Input
• Very low current
•
•
•
1 A AC
•
1 A AC
5 A AC
•
1 V AC
•
•
1,000/1
•
1,000/5
•
5 A AC
•
•
1 A AC
3 A AC
1,000/1
250/5
500/5
1,000/5
•
1A/1V
10A/1V
100A/1V
1,000A/1V
•
3,000/1
•
3,000/3
•
30 Hz... 10 kHz ≤ 0.5 % P01120301
•
•
30 Hz... 10 kHz ≤ 0.5 % P01120303
30 Hz... 10 kHz ≤ 1%
•
•
•
≤ 3%
•
•
P01120306
48 Hz... 1 kHz
≤ 2%
≤ 1%
≤ 1%
10 Hz... 3 kHz
≤ 0.7%
≤ 0.5 %
≤ 0.3% P01120309
≤ 0.2%
30 Hz... 5 kHz
≤ 0.5 % P01120064
30 Hz... 5 kHz
≤ 0.5 % P01120055A
P01120307
•
•
4.5 V DC
3 V RMS
4.5 V peak
•
1mA/1mV
DC... 2 kHz
≤ 1%
P01120067
•
•
4.5 V DC
3 V RMS
4.5 V peak
•
1mA/10mV
DC... 1.5 kHz
≤ 1%
P01120074
•
•
2 V DC
1.5 V AC
150 mV AC/DC
•
1A/1V
DC... 2 kHz
≤ 2%
1A/1mV
DC... 8 kHz
≤ 1.5 %
•
•
2 V AC
1.5 V AC
0.8 V AC/DC
•
1A/1V
DC... 2 kHz
≤ 2%
1A/10mV
DC... 8 kHz
≤ 4%
1 the higher value corresponds to 120% of the max. rated value
2 Reshaping of AC signal by diodes
3 Lead + electronic unit with Ø 4 mm safety plugs, 19 mm spacing, forK series
P01120030A
P01120040A
AC/DC current measurement
• Typical accuracy
(frequency in Hz)
• Bandwidth
• Automatic DC zero
(input/output)
• Output protected
against overvoltage
• Transformation ratio
(oscilloscopes)
Specific features
• BNC connector
• Female sockets ø 4 mm
• Leads
+ safety plug ø 4 mm
• Voltage
• Current
• ~ AC
--- DC
• ...
Output / Connections
• High current
• Medium current
• Low current
Model
Series
Input
• Very low current
To order
26 mm
224 m
m
AC/
DC
0.5 to 400 A AC
0.5 to 600 A DC
PAC10
0.2 to 40 A AC
0.4 to 60 A AC
0.5 to 400 A AC
0.5 to 600 A DC
PAC11
97 mm
• •
600 mV
AC/DC
• •
•
1A/1mV
600 mV
AC/ DC
•
1A/10mV
• •
1.4 V AC/DC
•
1A/1mV
• •
1.4 V AC/DC
•
1A/10mV
DC... 5 kHz
•
1A/1mV
DC... 10 kHz
P01120070
≤ 2%
≤ 1.5 %
≤ 2%
P01120068
20 mm
0.5 to 1,000 A AC
0.5 to 1,400 A DC
PAC20
224 mm
0.2 to 100 A AC
0.4 to 150 A DC
0.5 to 1,000 A AC
0.5 to 1,400 A DC
PAC21
97 mm
DC... 5 kHz
•
1A/1mV
DC... 10 kHz
P01120071
≤ 2%
≤ 1.5 %
≤ 2.5 %
P01120069
(1) The higher value corresponds to 120% of the max. rated value (2) Lead + electronic housing with Ø 4 mm safety plugs, centre distance 19 mm, for K series.
Measurement
on oscilloscope
Output / Connections
Y7N
C160
AC
0.5 A to 600 A peak
6 V peak
10 A/1 V
3 V peak
100 A/1 V
1 A to 2.000 A peak
2 V peak
1.000 A/1 V
1 A/10 V
MA200
30-300/3
(25 cm)
0.5 A…45 A peak
0.5 A…450 A peak
5 A…4,500 A peak
0.05 A to 10 A peak
1 A to 100 A peak
4.5 V peak
4.5 V peak
4.5 V peak
1 V peak
Typical accuracy
Bandwidth (frequency in Hz)
≤ 2%
3 V peak
0.5 A…450 A peak
Power measurement (low phase shift)
5Hz to
10kHz
1 A to 300 A peak
0.5 A…45 A peak
Automatic DC zero
≤ 1,5 %
0.1 A to 30 A peak
0.9 V peak
Output protected against overvoltages
BNC connector (coaxial)
Female sockets ø 4 mm
Transformation ratio
(input/output)
40Hz to
40kHz
1 mA / 1 mV
1 A to 900 A peak
≤ 2%
1 A / 10 mV
1.2 V peak
MA200
30-300/3
(17 cm)
E3N
1 A / 100 mV
1 A to 1.200 A peak
1 A to 9,000 A peak
MA200
3000 /3
(35 cm)
Lead + Ø4 mm safety plugs (3)
Voltage
Current
DC
AC
High current
Medium current
0.1 A to 60 A peak
1 A to 90 A peak
D38N
MA 200
Specific features
1 A/1mV
1 A/0.1mV
100 mV/A
10 mV/A
100 mV/A
10 mV/A
1 mV/A
1 A / 10 mV
1 A / 1 mV
10Hz to
100kHz
30Hz to
50kHz
To
order
P01120409
P01120075
≤ 3%
≤ 2%
P01120308
≤ 1%
≤ 2%
5 Hz… 1MHz
phase shift
at 1kHz ≤ 1.5
+ 0.3 A
5 Hz… 1MHz
phase shift
at 1kHz ≤ 1.5
+ 0.3 A
5 Hz… 1MHz
phase shift
at 1kHz ≤ 1.5
+ 0.3 A
≤ 1%
≤ 1%
≤ 1%
DC to
100kHz
≤ 3%
DC to
10kHz
≤ 1,5 %
DC to
10kHz
≤ 1,5 %
≤ 4%
P01120057A
P01120570
P01120571
P01120572
P01120043A
0.2 A to 60 A peak
AC/
DC
PAC12
0.4 A to 60 A DC
0.5 A to 600 A peak
600 mV peak
1 A / 10 mV
1 A / 1 mV
≤ 2%
P01120072
0.5 A to 600 A DC
0.2 A to 150 A peak
PAC22
0.4 A to 150 A DC
0.5 A to 1.400 A peak
0.5 A to 1.400 A DC
1.4 peak
1 A / 10 mV
1 A / 1 mV
≤ 2,5 %
P01120073
(1) The higher value corresponds to 120 % of the max. rated value
(3) Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the AmpFLEX series
MN60
Low current
Model
Very low current
Series
Input
Measurement range (1)
33
Current measurement
AC current measurement
TRMS digital ammeters
with flexible sensors
MA400D
Display range
Measurement range
Resolution
Accuracy
Sensor clamping diam. / length
Bandwidth
Power supply
Safety
MA4000D
4 A AC
40 A AC
400 A AC
40 A AC
400 A AC
4,000 A AC
0.020 A…
3.999 A
4.00 A…
39.99 A
40.0 A…
399.9 A
0.01 A…
39.99 A
40.0 A…
399.9 A
400 A…
3,999 A
1 mA
10 mA
100 mA
10 mA
100 mA
1A
± (2 % + 10 cts) ± ( 1.5 %+ 2 cts) ± (1.5 %+ 2 cts)
± (2 %+ 10 cts)
MA400D-170: Ø 45 mm / 170 mm
MA400D-250: Ø 70 mm / 250 mm
MA4000D-350: Ø 100 mm / 350 mm
10 Hz … 3 kHz
2 x 1.5 V AAA/LR3 batteries
IEC 61010 CAT IV 600V
Operating temperature
0°C to +50°C
Instrument weight
Approx. 130 g
Casing dimensions
100 x 60 x 20 mm
Length of connection cable
± (1.5 %+ 2 cts) ± (1.5 %+ 2 cts)
0.8 m
State at Delivery
1 DigiFLEX sensor delivered in a blister pack with 2 x 1.5V AAA batteries, 1 elastic strap and an operating manual in 5 languages
To order
MA400D-170
> P01120575Z
MA400D-250
> P01120576Z
MA4000D-350
> P01120577Z
34
Accessories & Replacement Parts
Bag 120x200x60
> P01298074
MULTIFIX accessories
> P01102100Z
Elastic strap
> P01102113
Input
Flexible
current
sensors
MA100
300-3000/3
(25 cm)
0.5 A…3,000 A
MA100
300-3000 /3
(35 cm)
0.5 A…3,000 A
MA100
300-3000/3
(35 cm)
0.5 A…3,000 A
0.5 A…300 A
0.5 A…300 A
0.5 A…300 A
0.5 A…300 A
MA200
30-300/3
(17 cm)
0.5 A…450 A peak
MA200
30-300/3
(25 cm)
0.5 A…450 A peak
A100
20-200/2
(45 cm)
0.5 A…45 A peak
0.5 A…45 A peak
5 A…4,500 Apeak
0.5 A…20 A
0.5 A…200 A
3 V AC
3 V AC
3 V AC
3 V AC
4.5 V peak
4.5 V peak
4.5 V peak
2 V AC
Bandwidth (frequency in Hz)
Power measurement (low phase shift)
Automatic DC zero
Output protected against overvoltages
BNC connector (coaxial)
Transformation ratio (input/output)
10 mV/A
100 mV/A
10 mV/A
10 mV/A
1 mV/A
10 mV/A
1 mV/A
10 mV/A
1 mV/A
10 mV/A
1 mV/A
5 Hz… 20KHz
phase shift
at 1kHz ≤ 1.5°
To
order
≤ 1%
P01120560
≤ 1%
P01120563
≤ 1%
P01120561
≤ 1%
P01120564
≤ 1%
P01120562
≤ 1%
P01120565
100 mV/A
≤ 1%
10 mV/A
+ 0.3 A
100 mV/A
5Hz… 1MHz
≤ 1%
phase shift
at 1kHz ≤ 1.5° + 0.3 A
10 mV/A
1 mV/A
1 A / 100 mV
1 A / 10 mV
≤ 1%
+ 0.3 A
P01120570
P01120571
P01120572
≤ 1%
P01120503
A100
2000/2
(45 cm)
0.5 A…2,000 A
2 V AC
1 A / 1 mV
≤ 1%
P01120501
A100
2000/2
(80 cm)
0.5 A…2,000 A
2 V AC
1 A / 1 mV
≤ 1%
P01120502
≤ 1%
P01120504
10 kHz…20 kHz ≤ 1 %
P01120505
≤ 1%
P01120506
≤ 1%
P01120507
≤ 1%
P01120508
≤ 1%
P01120509
A100
0.2-2 k/2
(45 cm)
0.5 A…2,000 A
A100
0.2-2 k/2
(80 cm)
0.5 A…2,000 A
A100
0.3-3 k/3
(45 cm)
0.5 A…3,000 A
A100
0.3-3 k/3
(80 cm)
0.5 A…3,000 A
A100
0.3-3 k/3
(120 cm)
0.5 A…3,000 A
A100
1-10 k/1
(120 cm)
0.5 A…10,000 A
0.5 A…200 A
0.5 A…200 A
0.5 A…300 A
0.5 A…300 A
0.5 A…300 A
0.5 A…1,000 A
2 V AC
2 V AC
3 V AC
3 V AC
3 V AC
1 V AC
1 A / 10 mV
1 A / 1 mV
1 A / 10 mV
1 A / 1 mV
1 A / 10 mV
1 A / 1 mV
1 A / 10 mV
1 A / 1 mV
1 A / 10 mV
1 A / 1 mV
1 A / 1 mV
1 A / 0.1 mV
• MiniFlex® MA100: the MA100 sensors are equipped with two types of outputs: via isolated Ø 4 mm banana
plugs with 19 mm spacing or via BNC.
• MiniFlex® MA200: the MA200 isolated current sensors are equipped with a BNC output. They offer high
bandwidth and are ideal for viewing transient signals.
• AmpFlex® A100: the range comprises 9 standard models dedicated to measuring alternating currents from
0.5 to 10 kA at industrial frequencies. Each flexible coil is connected by a screened cable to a small box
containing the processing electronics and a standard 9 V battery. The spacing of the sockets (19 mm) facilitates
direct connection to any type of multimeter, tester or recorder equipped with an AC voltage input (impedance
Z > 1MΩ).
(1) The higher value corresponds to 120 % of the max. rated value
(3) Lead + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the AmpFLEX series
0.5 A…3,000 A
3 V AC
100 mV/A
Typical accuracy
0.5 A…30 A
MA100
300-3000/3
(25 cm)
MA200
3000 /3
(35 cm)
A 100
Specific features
Female sockets ø 4 mm
0.5 A…300 A
3 V AC
Lead + Ø4 mm safety plugs (3)
MA100
30-300 /3
(17 cm)
0.5 A…30 A
Voltage
0.5 A…300 A
Current
MA100
30-300/3
(17 cm)
DC
MA 100
AC
Model
High current
Medium current
Low current
Very low current
Series
MA 200
Output / Connections
Meetgebied (1)
Accessories
For unlimited operation of your AmpFlex®:
replace the battery with a mains adapter.
Adapter for AmpFlex® Adapter for MA100 Adapter for MA200 > P01101968
> P01102086
> P01102087
35
Test and Measurement Accessories
Banana connection accessories, Ø 4 mm
Moulded leads
Model
Description
Specifications
Reference
Set of 2 red/black moulded PVC leads
Straight isolated male plug Ø 4 mm –
Straight isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295450Z
Set of 2 red/black moulded PVC leads
Straight isolated male plug Ø 4 mm –
Elbowed isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295451Z
Set of 2 red/black moulded Silicone
leads
Straight isolated male plug Ø 4 mm –
Straight isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295452Z
Set of 2 red/black moulded Silicone
leads
Straight isolated male plug Ø 4 mm –
Elbowed isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295453Z
Standard leads
Set of 2 red/black PVC leads
Straight isolated male plug Ø 4 mm –
Straight isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 600 V CAT IV /
1,000 V CAT III
P01295288Z
Set of 2 red/black PVC leads
Straight isolated male plug Ø 4 mm –
Elbowed isolated male plug Ø 4 mm
• 15 A
• 1.5 m
• 600 V CAT IV /
1,000 V CAT III
P01295289Z
Set of 2 red/black PVC leads
Straight isolated male plug Ø 4 mm with
rear connection – Straight isolated
male plug Ø 4 mm with rear connection
• 20 A
• 2 m
• 600 V CAT III
P01295290Z
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295455Z
• 15 A
• 1.5 m
• 1,000 V CAT IV
P01295456Z
Leads with built-in test probes
36
Set of 2 red/black PVC test-probe
leads
Straight isolated male plug Ø 4 mm
Set of 2 red/black PVC test-probe
leads
Elbowed isolated male plug Ø 4 mm
Banana connection accessories, Ø 4 mm
Model
Description
For CAT IV and CAT III installations
Set of 2 red/black moulded
test probes
Specifications
Female plug Ø 4 mm
• CAT IV / CAT III 1,000 V
Reference
P01295454Z
For CAT II installation and below
Set of 2 moulded test probes Ø 4 mm
Female plug Ø 4 mm
• CAT II 300 V
P01295458Z
Set of 2 moulded test probes Ø 2 mm
Female plug Ø 4 mm
• CAT II 300 V
P01295460Z
Complies with NF C 18-510
and IEC 61010-031+A1:2008
IP2X test probe
Elbowed isolated male plug
• 15 A
• 1.5 m
• 600 V CAT IV
P01295461Z
Set of 2 IP2X PVC leads
for voltage detectors
Complies with.NF.C.18-510
and IEC 61010-031+A1:2008
IP2X test probe Ø 2 mm
Elbowed female plug Ø 4 mm
• 15 A
• 1.5 m
• 600 V CAT IV
P01295463Z
Set of 2 IP2X leads
for voltage detectors for C.A 7xx
IP2X test probe Ø 4 mm
Elbowed female plug Ø 4 mm
• 15 A
• NF C 18-510 /
IEC 61243-3 1,000 V
IP2X
Set of 2 IP2X PVC leads
for digital multimeters
For
• 1.5 m:
P01295462Z
• 0.25 m & 0.85 m:
P01295285Z
37
Test and Measurement Accessories
Protection and transport accessories
P01298072
MC 0160B
RE 0237
MC 0160B
+ MC 0159B
P01298069
P01298004
P01298068
P01298071
Product
Reference
Description
C.A 6511 / C.A 6513
P01298016
Sheath
C.A 6523 / C.A 6525
P01298049
Bag
P01298065Z
Hard case
P01298532
Soft case
P01298048
Hard case
P01298043Z
Bag
HX0052
Soft carrying case for "hands-free" use
MC0160B
Sheath
MC0159B
Handle
AE0193
Soft carrying case
AE0227
Hard case
AE0237
Sheath (except MX 26)
AE0190
Hard case
MX 24B
HX0009
Hard case
K clamp
P01298039
Soft carrying case
P01298071
Soft carrying case 270 x 195 x 65 mm
P01298004
Soft carrying case 320 x 255 x 75 mm
P01298072
Soft carrying case 440 x 310 x 135 mm
P01298068
On-site case 272 x 248 x 130 mm
P01298069
On-site case 272 x 248 x 182 mm
C.A 704 / C.A 730 / C.A 735 / C.A 745 / C.A 760
F01 / F03 / F05 / F07
F15
MTX 3281/3282/3283
MX 20HD / MX 44HD /
MX 57 Ex / MX 58 HD / MX 59 HD
MX 21 / MX 22 / MX 23 / MX 24B / MX 26
Standard
38
Index
A
... by function
Accessories:
• Ø 4 mm banana connectors • transport accessories
(soft cases, hard cases, bags)
• protective accessories
(soft cases, hard cases, bags)
• Essailec AmpFlex® TM A100 AmpFlex® clamps ATEX multimeter AVG digital multimeter AVG multimeter for difficult environments C
Clamps:
• AC current clamps • AC/DC current clamps • digital multimeter clamps • earth clamps and loop testers A
p.36-37
p.38
p.38
p.28
p.35
p.28
p.12
p.12
p.12
p.28/33/34
p.28/33/34
p.08-09
p.23
D
DataView software Digital insulation testers E
Earth and resistivity kit p.21
Earth and resistivity testers and adapter
for pylon earth measurements p.22
Earth and resistivity testers p.21
Electrical energy analysers
for three-phase networks p.26/27/28
Electrical energy analysers for three-phase networks p.29
Flexible current sensors p.33-34-35
I
Installation testers p.17
Light meters p.31
Megohmmeters (see Installation Testers)
Micro-ohmmeters Mini AC current clamps p.24
p.32
L
M
.... by product
A196-450/A193-450/A193-800
AmpFlex® A100 AmpFlex® clamps flexible current sensors
C.A 740N/760N C.A 811/813 C.A 871/879 C.A 1725/1727 C.A 1864/1866 C.A 5271/5273/5275/5277 C.A 6116N/6117 C.A 6240/6250 C.A 6416/6417 C.A 6460/6462/6470N/6471 C.A 6472/6474 C.A 6505 C.A 6523/6525 C.A 6541/6543/6545/6547/6549 C.A 6550/6555 C.A 8220/ 8230 C.A 8331/8333/8336/8435 C100 to C173 C193 two-pole voltage absence testers p.10
light meters p.31
non-contact thermometers p.31
tachometers p.31
non-contact thermometers p.31
TRMS multimeters p.11
installation testers p.17
micro-ohmmeters p.24
earth clamps and loop testers p.23
earth and resistivity testers p.21
earth and resistivity testers
with adapter for pylon earth measurements p.22
digital insulation tester p.19
digital insulation testers
p.18
digital insulation testers p.19
digital insulation testers p.20
electrical energy analysers
for three-phase networks p.29
electrical energy analysers
for three-phase networks p.26-27-28
AC current clamps p.32-33
AC current clamp p.28
D30CN / D36N D38N AC DataView DTR 8510 AC current clamps current clamp software
single-phase ratiometer p.32
p.33
p.19/27
p.24
E1N / E6N
AC / DC current clamps
E3N AC / DC current clamps
Earth and resistivity kit Essailec p.32
p.28/33
p.21
p.28
C
D
E
p.19 /27
p.19-20
p.28
p.35
F
N
Non-contact thermometers p.31
On-site digital oscilloscopes Oscilloscopes with isolated channels p.15
p.14
Power Analyser transfer software Power and energy loggers p.27
p.30
Single-phase ratiometer p.24
Tachometers TRMS digital multimeter TRMS graphical digital multimeters TRMS multimeters for difficult environments TRMS multimeters Two-pole voltage absence testers p.31
p.12
p.13
p.12
p.11
p.10
O
P
R
T
F201/203/205 F401/403/405/F407 F601/603/605/F607 digital multimeter clamps
digital multimeter clamps digital multimeter clamps K1/ K2 AC / DC current clamps
MA 100 MA 200 MA193 MA400D/MA4000D MINI 01/02/03/05/09
MN 08 à MN 89 MN60 MN93/MN 93A MTX 3281/3282/3283 MX 44HD MX 57Ex MX 58HD/59HD MX22 AVG MX24B flexible current sensors p.35
flexible current sensors p.33/35
AC current clamp p.28
flexible current sensors p.34
mini AC current clamps p.32
AC current clamps p.32
AC current clamp p.33
AC current clamps p.28
TRMS graphical digital multimeters p.13
AVG multimeter for difficult environments p.12
ATEX multimeter p.12
TRMS multimeters for difficult environments p.12
digital multimeter p.12
TRMS digital multimeter p.12
K
M
O
Ø 4 mm banana connection accessories OX 5022/5042
on-site digital oscilloscopes OX 7042/7062 oscilloscopes with isolated channels OX 7102/7104/7202/7204 oscilloscopes with isolated channels P
p.08-09
p.08-09
p.08-09
p.32
p. 36-37
p.15
p.14
p.14
PAC 10/11/12 AC/DC current clamps PAC 20/21/22 AC/DC current clamps PAC93 AC/DC current clamps PEL 102/103 power and energy loggers Power Analyser transfer software Protective accessories (soft cases, hard cases, bags) Transport accessories (soft cases, hard cases, bags) p.33
p.33
p.28
p.30
p.27
p.38
p.38
Y1N Y7N
p.32
p.33
Y
AC current clamp AC current clamp 39
A local service for a better service
Chauvin Arnoux
190, rue Championnet
75876 Paris Cedex 18 - France
[email protected]
www.chauvin-arnoux.com
tel: +33 1 44 85 44 38
fax: +33 1 46 27 95 59
906131100 • Ed. 3 - 2014 • Non-contractual document. Photos: Chauvin Arnoux Group. Specifications must be confirmed before ordering.
Chauvin Arnoux Test and Measurement
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement