Div 2 - GAI
Hazardous Area Telephones
GAI-TRONICS®
Division 2 Industrial Telephones
Features
• Hazardous Area approved for:
Model 226-002
Div. 2 Tough Phone
Class I, Division 2, Groups A, B, C, D;
Class II, Division 2, Groups F and G;
Class III
• Economical Communications for
Division 2 Areas
Model 341-001
Indoor Div. 2 Telephone
• Indoor and Outdoor Models
• Anti-corrosive Enclosures
• Hearing Aid Compatible (HAC) with
Pushbutton Volume Control
• Hytrel Coiled Cord or Straight Armored Cord
Model 351-001
Outdoor Div. 2
Telephone
• Sealed Chrome-plated Keypad
• Extreme Operating Temperature Range
• Conformal Coating on PCBA
GAI-Tronics Division 2 Industrial Telephones are approved
for select Division 2 areas. Three available models offer a
selection of high-quality, durable telephones for safe communications in your facility.
Providing communications in Division 2 areas has traditionally required the installation of Division 1 approved
equipment which exceeds the Division 2 standards and
drives costs higher than necessary. GAI-Tronics offers economical alternatives. Our Model 341-001 Indoor Industrial
Telephone and Models 351-001 and 226-002 Outdoor
Industrial Telephones provide fully-functional, line-powered communications that are approved for use in Class I,
Division 2, Groups A, B, C, D; Class II, Division 2, Groups F
and G; Class III classified areas. Our outdoor models have a
Option Chart
Option Code
LD
AC
A2
H6
H1
H2
Type 3R weatherproof rating. Housed in corrosion-resistant
enclosures, these units offer superior resistance to chemicals, solvents, salts, and extreme temperatures. Each unit is
equipped with a chrome-plated zinc keypad that is fully
sealed to prevent entry of dirt, contaminants, and water.
The coiled handset cord on our non-metallic models
(341-001 and 351-001) is molded of thermoplastic elastomer to provide outstanding performance, memory, and
long life. The armored cord on our Model 226-002 Tough
Phone model is rated at 800 lbs. of pull strength. The nonmovable handset cradle uses a proximity-detecting switch
to take the phone off-hook.
All models are designed for operation within a temperature
range of -40° C (-40° F) to 60° C (140° F).
To order a Div. 2 Telephone with the desired option, simply add the option code(s) to the part no. as a suffix (Examples: 351-001LD
or 341-001H2)
Description
Keylock Door Option
15” Armored Handset Cord Option
29” Armored Handset Cord Option
6 Ft. (extended) Hytrel® Handset Cord Option
15 Ft. (extended) Hytrel® Handset Cord Option
25 Ft. (extended) Hytrel® Handset Cord Option
226-002
X
Standard
Not available
X
Not available
Not available
341-001
No door
X
X
Standard
X
X
351-001
X
Not available
Not available
Standard
X
Not available
Specifications for Division 2 Industrial Telephones
Electrical (Typical)
Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 to 3,000 Hz
Inter-digit Pause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ms
Min. Loop Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Signaling tone (DTMF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ms Tone Duration
Supervisory DC Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum 20 mA dc, Maximum 60 mA dc
Supervisory DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V dc to 60 V dc (not polarity sensitive)
Network Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loop Start
Network Signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DTMF
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5-foot (1.98 m ) modular line cord
Environmental
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 40°F to +140°F (-40°C to +60°C)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing
Model 226-002 - Mechanical
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4” thick cast aluminum
Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gray polyurethane enamel
Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.125-inch brushed anodized aluminum (secured with security screw − Torx T-25)
Handset/Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . “G” style with armored cord and volume switch
Keypad (Braille) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chrome-plated zinc
Ringer Level at 2 feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Open @ 92 dBA SPL
Door Closed @ 74 dBA SPL
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.7 W x 13.5 H x 6.1 D inches (246 x 343 x 155 mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.0 lbs (8.16 kg)
Model 341-001 and 351-001 - Mechanical
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-metallic
Handset/Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . “G” style handset/Hytrel®, 6-foot extended length (standard) and volume switch
Dimensions:
Model 341-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 W x 9.5 H x 6.9 D inches (204 x 242 x 174 mm)
Model 351-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.4 W x 13.2 H x 7.4 D inches (239 x 334 x 189 mm)
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Four (4) 0.280-inch diameter holes
Weight:
Model 341-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 lbs. (2.7 kg)
Model 351-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2 lbs. (3.72 kg)
Ringer Level at 2 feet:
Model 341-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 dBA SPL
Model 351-001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Open @ 91 dBA SPL; Door Closed @ 84 dBA SPL
FCC Information
FCC Registration Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . US: ADGTE10A-46048HAC
Ringer Equivalence Number (REN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0A/1.3B
Network Connection (USOC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ11
Meets hearing aid compatibility magnetic field intensity and volume control technical standards per FCC Sections 68.316 and 68.317.
IC Information (Canada)
IC Certification Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82211754
Ringer Equivalence Number (REN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0A/1.3B
Connecting Methold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CA11A
Hazardous Area Approvals
Class I, Division 2, Groups A, B, C, D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI / ISA 12.12.01 / CSA - C22.2 No. 157
Class II, Division 2, Groups F and G; Class III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI / ISA 12.12.01 / CSA - C22.2 No. 157
Safety of Information Technology Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL508 & CAN/CSA-C22.2 NO. 60950-00
Enclosures for Electrical Equipment (Models 351-001 and 226-002 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 50 Type 3R / NEMA 3R
Ordering Information
226-002
341-001
351-001
230-001
Div. 2 Tough Phone
Indoor Div. 2 Telephone
Outdoor Div. 2 Telephone
Pole Mtg. Kit for 351-001
®
GAI-TRONICS
231-001 Pole Mtg. Kit for 341-001
232-001 Pole Mtg. Kit for 226-002
233-001 Security Screwdriver for 226-002
USA
UK
Italy
Malaysia
Australia
Toll Free: 1 (800) 492-1212 Tel: (610) 777-1374 Fax: (610) 796-5954 www.gai-tronics.com
Tel: +44 (0)1283 500500 Fax: +44 (0)1283 500400 www.gai-tronics.co.uk
Tel: +39 02 48601460 Fax: +39 02 93663110 www.gai-tronics.it
Tel: +60-3-8945-4035 / 8945-7348 Fax: +60-3-8945-4675 www.gai-tronics.com
Tel: 011-61-28-851-5000 Fax: 011-61-29-899-2490 www.austdac.com.au
Quality Management System Certified by DNV-GL - ISO 9001:2008. The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.
Pub. 120601 Rev 2/2017
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement