R. STAHL KVM DVI1-CAT, KVM DVI1-MM, KVM DVI1-SM, KVM DVI2-CAT, KVM DVI3-CAT, KVM DVI3-MM-FO, KVM DVI3-SM-FO, KVM DVI3-RU-CAT, KVM DVI3-RU-MM-FO, KVM DVI3-RU-SM-FO KVM unit Operating instructions
Below you will find brief information for KVM DVI1-CAT, KVM DVI1-MM, KVM DVI1-SM, KVM DVI2-CAT, KVM DVI3-CAT, KVM DVI3-MM-FO, KVM DVI3-SM-FO. All transmission units are used for classic point-to-point data connection from a PC outside of the production area to an on-site HMI. The data transmission to the PC is via VGA / DVI or USB / PS2 and a copper or optical fibre connection to the on-site HMI, realised as digital data transfer. Depending on cable connection and transmission technology the distance between the transmission unit and the Remote HMI ranges from 140 m (459.32 ft) (copper cable) to 10,000 m (32,808.40 ft) (optical fibre).
Advertisement
Advertisement
Operating instructions
KVM Units
KVM-*-CAT-*
KVM-*-MM-*
KVM-*-SM-*
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
Operating Instructions Version:
Issue date:
01.00.03
28.06.2017
KVM units Disclaimer
Disclaimer
Publisher and copyright holder:
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
Registered place of business: Cologne
Court of registration:
VAT number:
District court Cologne, HRB 30512
DE 812 454 820
Phone:
Fax:
E-mail:
(switchboard)
(hotline)
(switchboard)
(hotline)
+49 (0) 221 76 806 [email protected]
- 1000
- 5000
- 4100
• All rights reserved.
• This document may not be reproduced in whole or in part except with the written consent of the publisher.
• This document may be subject to change without notice.
Any warranty claims are limited to the right to demand amendments. Liability for any damage that might result from the content of this description or all other documentation is limited to clear cases of premeditation.
We reserve the right to change our products and their specifications at any time, provided it is in the interest of technical progress. The information in the current manual (in the internet and on
CD / DVD / USB stick) or in the operating instructions included with the device applies.
Trademarks
The terms and names used in this document are registered trademarks and / or products of the companies in question.
Copyright © 2017 R. STAHL HMI Systems GmbH. Subject to alterations.
Page 2 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Specific markings
Specific markings
The markings in these operating instructions refer to specific features that must be noted.
In detail, these are:
DANGER
This sign alerts users to hazards that will result in death or serious injury if ignored !
WARNING
This sign alerts users to hazards that may result in death or serious injury if ignored !
CAUTION
This sign alerts users to hazards that may damage machinery or equipment or result in injury if ignored !
ATTENTION
Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment !
NOTICE
Information highlighted by this symbol indicates important information of which particular note should be taken !
DOCUMENTATION
Information highlighted by this symbol refers to a different chapter or section in this manual or other documentation or a web-page !
Warnings
Caution !
The device surface may heat up at ambient temperatures higher than 45 °C !
Caution at contact !
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 3 of 28
KVM units Table of contents
Table of contents
Description
External inherently safe optical interface
Installation safety information
Safety information for operation
KVM-DVI3 data connection to 6x7 unit
Ethernet copper (Tx) connection
Ethernet optical fibre (MM / SM) connection
KVM-DVI3 connection to the host PC
Page 4 of 28
Page
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units
Local display of the host PC at the KVM-DVI3
Repairs / hazardous substances
Table of contents
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 5 of 28
KVM units Preface
1 Preface
These operating instructions contain all relevant information on the KVM transmission units for connection to HMIs of the SERIES 600 devices. They also contain information on the connection and installation (etc.) of these devices.
All data relevant to explosion protection from the EC-type examination certificate were copied into these operating instructions.
NOTICE
For the correct operation of all associated components please note, in addition to these operating instructions, all other operating instructions enclosed in this delivery as well as the operating instructions of the additional equipment to be connected !
DOCUMENTATION
Please note that the Ex certificates of the KVM transmission units are part of the certificates of the ET-xx7
HMI devices. You can find these certificates in a separate document (CE_ET-xx7) !
You can find this document online at www.stahl-hmi.de
or request a copy from R. STAHL HMI Systems GmbH.
Page 6 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Function of transmission unit
2 Function of transmission unit
All transmission units are used for classic point-to-point data connection from a PC outside of the production area to an on-site HMI. The data transmission to the PC is via VGA / DVI or
USB / PS2 and a copper or optical fibre connection to the on-site HMI, realised as digital data transfer. Depending on cable connection and transmission technology the distance between the transmission unit and the Remote HMI ranges from 140 m (459.32 ft) (copper cable) to
10,000 m (32,808.40 ft) (optical fibre).
The transmission technologies available are the KVM Classic versions DVI1, DVI2 and DVI3, for which the appropriate transmission units exist (see type key).
2.1 General Notes
NOTICE
Note:
KVM transmission units must be selected to suit the SERIES 600
KVM-Systems !
2.1.1 Device allocation
KVM transmission units
KVM-DVI1-CAT
KVM-DVI1-MM-FO
KVM-DVI1-SM-FO
KVM-DVI2-CAT
SERIES 600 KVM-Systems
Can be used with
ET-/MT-/IT-6x7-DVI1-CAT-*
ET-/MT-/IT-6x7-DVI1-MM-FO-*
ET-/MT-/IT-6x7-DVI1-SM-FO-*
ET-/MT-/IT-6x7-DVI2-CAT-*
KVM-DVI3-CAT
KVM-DVI3-MM-FO
KVM-DVI3-SM-FO
KVM-DVI3-RU-CAT
KVM-DVI3-RU-MM-FO
KVM-DVI3-RU-SM-FO
ET-/MT-/IT-6x7-DVI3-CAT-*
ET-/MT-/IT-6x7-DVI3-MM-FO-*
ET-/MT-/IT-6x7-DVI3-SM-FO-*
Standard devices (screen, mouse, keyboard)
Standard devices (screen, mouse, keyboard)
Standard devices (screen, mouse, keyboard)
DOCUMENTATION
Any other device design, according to type key.
See operating instructions for each HMI device series
(ET-/MT-/IT-xx7).
2.2 Notes on DVI2 and DVI3
NOTICE
With regard to the USB connection between the KVM transmission unit and the host PC, users need to ensure that the host PC has a
USB 2.0 chip set !
The more recent USB 3.0 chip sets may cause problems with the connection and its functions !
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 7 of 28
KVM units Type allocation
2.3 Notes on DVI3
2.3.1 Resolutions
The DVI3 transmission units represent all resolutions at a ratio of 1:1. The image at the HMI device is therefore always displayed with its actual size and there is no scaling.
If the resolution of the image displayed is smaller than the natural resolution of the HMI device display, a black margin will appear around the image.
Image resolution = display resolution image resolution < display resolution
2.3.2 Caveat
Access to the host PC's BIOS via the KVM unit is not possible with all PC types. The BIOS has to support USB 2.0 (high speed) communication.
2.3.3 Brightness adjustment
The display brightness of the 6x7 HMI device is automatically reduced to 50% after 15 minutes without any operation. As soon as there is any activation via touch, button or keyboard the brightness level returns to 100%.
3 Type allocation
Since the beginning of 2013, the T-series devices have been allocated new type names according to the following pattern:
To avoid having to re-write certifications, the names in the certificates remain the same, but the devices receive new names.
In the interest of a clear link between device type and certificate, both device names are listed on the type plate from 01.04.2013 onwards.
3.1 Type marking
Old (certificate)
T-Ex-KVM*-CAT7*
T-Ex-KVM*-MM*
New
KVM-*-CAT*
KVM-*-MM*
T-Ex-KVM*-SM* KVM-*-SM*
* = alphanumeric or symbolic characters without relevance to explosion protection.
# = numeric character without relevance to explosion protection.
DOCUMENTATION
For the exact new device name and model please refer to the type code.
Page 8 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Technical Data
4 Technical Data
Function / Equipment
Power supply
Voltage supply
Power
Recommended fuses
MTBF
Power supply 2
Voltage supply
Interfaces
Ethernet
Copper (CAT)
Optical fibre (MM-FO)
Optical fibre (SM-FO)
DVI
USB
PS/2
Serial
Audio
Data cable
Copper (CAT)
Optical fibre (MM-FO)
Optical fibre (SM-FO)
Data cable lengths
Copper (CAT)
Optical fibre (MM-FO)
50 µm core
62.5 µm core
Optical fibre (SM-FO)
Enclosure
Enclosure protection type
Operating temperature range
Cold start temperature
Operation
Short-term temperature
Storage temperature range
Relative humidity
Dimensions [mm] / [ft] (W x H x D)
Weight [kg] / [lbs]
KVM-DVI1-* KVM-DVI2-*
either copper or optical fibre direct connection, gigabit
KVM-DVI3-*
via IEC plug (female)
100 - 240 VAC, 50 - 60 Hz typically 5 W / max. 10 W (typically 17 BTU / max. 34 BTU)
1.0 AT typically 50,000 h at 20 °C / 68 °F redundant connection, via mini-DIN / Hosiden plug
12 VDC
-
-
-
- direct connection, gigabit, multi-mode
intrinsically safe (Ex op is) direct connection, gigabit, single mode
intrinsically safe (Ex op is)
1 x DVI, 1 x DVI / VGA
1 x plug type B
2 x mouse, 2 x keyboard
RS-232 line in / out
-
-
1 x DVI-D in, 1 x DVI-D out
1 x plug type B
- via USB / RS-232 converter via USB / Audio converter direct connection, gigabit, multi-mode
intrinsically safe (Ex op is) direct connection, gigabit, single mode
intrinsically safe (Ex op is)
1 x DVI-I in, 1 x DVI-I out
1 x plug type B
-
RS-232 line in / out
CAT7 installation cable AWG 22 multi-mode optical fibre cable (50 or 62.5 / 125 µm core / external cross section) single-mode optical fibre cable (9 µm core cross section and 125 µm external cross section)
140 m / 459.32 ft
550 m / 1,804.46 ft
300 m / 984.25 ft
10,000 m / 32,808.40 ft
500 m / 1,640.42 ft
-
-
-
-
150 m / 492.13 ft
550 m / 1,804.46 ft
300 m / 984.25 ft
10,000 m / 32,808.40 ft
+5 °C ... +40 °C /
+41 °F … +104 °F
+5 °C ... +40 °C /
+41 °F … +104 °F
+5 °C ... +40 °C /
+41 °F … +104 °F
-20
°C … +70 °C /
-
4 °F … +158 °F
20 to 80% at +40 °C / +104
°F,
non-condensing desktop enclosure, aluminium
IP20
-10 °C ... +50 °C /
+14
°F … +122 °F
-20
°C … +50 °C /
-
4 °F … +122 °F
-30
°C … +60 °C /
-22
°F … +140 °F
-20
°C … +70 °C /
-
4 °F … +158 °F
10 to 90% at +40 °C / +104 °F, non-condensing
210 x 44 x 210 /
0.689 x 0.144 x 0.689
210 x 44.45 x 165 /
0.689 x 0.146 x 0.541
1.0 / 2.2
210 x 44.45 x 165 /
0.689 x 0.146 x 0.541
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 9 of 28
KVM units Certificates DVI1 and DVI3
5 Certificates DVI1 and DVI3
Of all associated equipment only the KVM transmission units with an optical fibre interface have a corresponding certificate.
Europe: according to ATEX Directive 2014/34/EU
International:
IECEx (International Electrotechnical Commision System for Certification to
Standards for Electrical Equipment for Explosive Atmospheres)
Asia:
GOST-R (Russian Certificate)
5.1 ATEX
The ATEX certificate is listed under the following certification number:
Certificate number: BVS 11 ATEX E 102 X
5.2 IECEx
The IECEx certificate is listed under the following certification number:
Certificate number: IECEx TUR 11.0075X
DOCUMENTATION
You can access all IECEx certificates on the official website of the IEC under their certificate number. http://iecex.iec.ch/iecex/iecexweb.nsf/welcome?openform
.
5.3 GOST-R
The GOST-R certification has the following number:
5.3.1
Certificate number:
Type approval
Number:
5.4 KGS
РОСС DE.ГБ04.B01882
PPC 00-048723
NOTICE Only valid for KVM-DVI3-* transmission units !
The KGS certificate is listed under the following certification number:
Certificate number: 12-GA4BO-0617X
NOTICE
NB:
In order to be able to operate these KVM transmission units in
Korea, each device type also requires a KCC certificate.
The following KVM units currently have such a KCC certificate:
T-Ex-KVM-DVI3 (KVM-DVI3-*)
Page 10 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units
6 Marking
Manufacturer
Type code
CE classification:
R. STAHL HMI Systems GmbH
KVM-DVI1-MM-FO* / KVM-DVI1-SM-FO*
KVM-DVI3-MM-FO* / KVM-DVI3-SM-FO* c
0158
BVS 11 ATEX E 102 X Testing authority and certificate number:
Ex classification:
ATEX guideline 2014/34/EU e
II (1) G [Ex op is Ga] IIC
II (1) D [Ex op is Da] IIIB
IECEx / GOST-R [Ex op is Ga] IIC
[Ex op is Da] IIIB
7 Permitted maximum values
Input:
Max. operating voltage U m
≤ 250 VAC
7.1 External inherently safe optical interface
Ethernet optical fiber (MM-FO)
Multi-mode
Wavelength
Radiant power max. radiant power:
850 nm
0.22 mW
35 mW
Ethernet optical fiber (SM-FO)
Single mode
Wavelength
Radiant power max. radiant power:
1310 nm
0.22 mW
35 mW
Marking
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 11 of 28
KVM units
8 Type code
KVM-DVI*-aa
Product type:
Product key structure
KVM-DVI1-CAT
KVM-DVI1-MM
KVM-DVI1-SM
KVM-DVI2-CAT
KVM-DVI3-CAT
KVM-DVI3-MM-FO
KVM-DVI3-SM-FO
KVM-DVI3-RU-CAT
KVM-DVI3-RU-MM-FO
KVM-DVI3-RU-SM-FO
Type code
Transfer medium
Transfer technology
Description
Version
KVM box with DVI1 transfer technology copper direct connection, gigabit
KVM box with DVI1 transfer technology direct optical fibre connection, multi-mode
KVM box with DVI1 transfer technology direct optical fibre connection, single-mode
KVM box with DVI2 transfer technology copper direct connection, gigabit
KVM box with DVI3 transfer technology copper direct connection, gigabit
KVM box with DVI3 transfer technology direct optical fibre connection, multi-mode
KVM box with DVI3 transfer technology direct optical fibre connection, single-mode
KVM box with DVI3 transfer technology,
Non-Ex receiving unit copper direct connection, gigabit
KVM box with DVI3 transfer technology
Non-Ex receiving unit direct optical fibre connection, multi-mode
KVM box with DVI3 transfer technology
Non-Ex receiving unit direct optical fibre connection, single-mode
Page 12 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Safety information
9 Safety information
9.1 General Safety Information
All relevant accident prevention regulations and the rules for electric installations have to be observed during installation, maintenace and operations. All persons involved in installation, commission, maintenance and repairs of this device and its accessories must be qualified accordingly and must have familiarised themselves with this manual and any associated documentation.
In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void.
National safety and accident prevention rules apply.
Use the device for its intended purpose only.
No changes to the device are permitted. The enclosure may only be opened by R.
STAHL HMI Systems GmbH.
The first four digits of the serial number on the type plate stand for the year of manufacture.
9.2 Cautionary note
ATTENTION
This is an EN 55022 Class A product.
In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
9.3 Installation safety information
The national assembly and installation rules and the generally accepted technical rules must be observed. The device and its accessories must be connected and operated acc ording to applicable standards, directives and installation guidelines. Only qualified personnel or personnel that has been instructed accordingly are allowed to install the device.
Only appropriate tools must be used for the installation.
The units must be earthed via the bolt at the back of the device.
We recommend you use screened cables with the device. Routing of the data cable may reduce performance.
At the place of installation voltage must not exceed 250 V and short-circuit current must not exceed 1500 A.
Before starting up the device you must ensure that it has been installed according to regulations and that neither the device nor its cables are damaged.
9.4 Safety information for operation
Operate the device only if it is clean and undamaged. If the device is in any way damaged, do not touch it to avoid injury. In the case of any damage that may compromise ingress protection (e.g. cracks, holes or broken components) the device must be taken out of commission immediately. Before the device is recommissioned the damaged components must be replaced.
In case of non-compliance or contravention of the above explosion-protection is no longer guaranteed and all warranty claims shall be null and void !
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 13 of 28
KVM units
10 Mechanical dimensions
10.1 KVM-DVI1
View:
Optical fibre interface
CAT interface
Dimensions in mm / ft:
210 x 44 x 210 / 0.689 x 0.144 x 0.689 (W x H x D)
10.2 KVM-DVI2
View:
Mechanical dimensions
Dimensions in mm / ft:
210 x 44.45 x 165 / 0.689 x 0.146 x 0.541 (W x H x D)
Page 14 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units
10.3 KVM-DVI3
View (CAT version):
View (optical fibre version):
Back view:
Dimensions in mm / ft:
210 x 44.45 x 165 / 0.689 x 0.146 x 0.541 (W x H x D)
Mechanical dimensions
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 15 of 28
KVM units Connections
11 Connections
11.1 KVM-DVI1
Definition
Power
Plug type
Red. power
DVI CPU
DVI / VGA out
USB CPU
Mouse CPU
Keyb. CPU
Mouse
Keyb.
RS232
Line out
Line in
Transmission
Connection
IEC connector
-
-
-
-
Mini-DIN / Hosiden connector
DVI-D connector
DVI-I connector
USB plug type B
PS/2
PS/2
PS/2
PS/2
Sub-D 9 pin socket
3.5mm TRS socket
3.5mm TRS socket
RJ45 connector
Pin
1
2
3
4
5
6
7
8
9
1……8
Signal
TRD0+
TRD0-
TRD1+
TRD1-
TRD2+
TRD2-
TRD3+
TRD3-
SHLD typical colour coding
White / Orange
Orange
White / Green
Blue
Blue / White
Green
White / Brown
Brown
Screen
Audio out
Audio in
Ethernet copper connection *
Definition
power supply
100 - 240 VAC of the KVM transmission unit redundant 12 VDC supply of the KVM transmission unit
DVI screen in, connection to the PC
DVI / VGA screen out, connection to local screen
USB in connection to the PC not used / not supported not used / not supported not used / not supported not used / not supported
RS-232 data Interface
Page 16 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units
Transmission
Connections
optical fibre connection type LC
Duplex connector
Ethernet optical fibre interface *
Ex op is
Tx Rx
NOTICE
11.2 KVM-DVI2
Definition
Power
Plug type
DVI-D in
* Please note that the Ethernet connection is designed either for an optical fibre connection (FO) or for a copper connection
(CAT7), depending on the version ordered !
In the case of an optical fibre connection the following cable is recommended:
Multi-mode: 50 µm core cross section and 125 µm external cross section
Single mode: 9 µm core cross section and 125 µm external cross section
Recommended cable length for USB, RS-232 and Audio: max. 3 m (10 ft)
Connection
IEC connector
DVI-D connector
Definition
power supply
100 - 240 VAC of the KVM transmission unit
DVI screen in, connection to the PC
DVI-D out DVI-D connector DVI screen out, connection to local screen
USB USB plug type B USB in
Ccnnection to the PC
Data out RJ45 connector Ethernet copper connection
1……8
6
7
8
9
Pin
1
2
3
4
5
Signal
TRD0+
TRD0-
TRD1+
TRD1-
TRD2+
TRD2-
TRD3+
TRD3-
SHLD typical colour coding
White / Orange
Orange
White / Green
Blue
Blue / White
Green
White / Brown
Brown
Screen
NOTICE
Audio and RS-232 only via a corresponding USB converter.
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 17 of 28
KVM units Connections
11.3 KVM-DVI3
Definition
Power
DVI / VGA in
DVI / VGA out
USB
Serial
Audio out
Audio in
Data
Plug type
Pin
2
3
4
5
8
5
9
Connection
IEC connector
DVI-I connector *
DVI-I connector *
USB plug type B
1
6
Signal
RxD
TxD
DTR
GND
CTS
Sub-D 9 pin socket**
Designation
Receive data
Transmit data
Data Terminal Ready
Ground
Clear to send
3.5mm TRS socket
3.5mm TRS socket
RJ45 connector
Definition
power supply
100 - 240 VAC of the KVM transmission unit
DVI / VGA screen in, connection to the PC
DVI / VGA screen out, connection to local screen
USB in connection to the PC
RS-232 data Interface
Audio out
Audio in
Ethernet (OSI Layer 1) copper interface ***
Data
Pin
1
2
3
4
5
6
7
8
9
1……8
Signal
TRD0+
TRD0-
TRD1+
TRD1-
TRD2+
TRD2-
TRD3+
TRD3-
SHLD typical colour coding *4
White / Orange
Orange
White / Green
Blue
Blue / White
Green
White / Brown
Brown
Screen optical fibre connection type LC
Duplex connector
Ethernet (OSI Layer 1) optical fibre interface ***
Ex op is
Page 18 of 28
Tx Rx
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units
NOTICE
Connections
* It is also possible to use a single link connection for the DVI connection.
** The named signals at the Sub-D socket are supported by the systems.
*** Please note that the Ethernet connection is designed either for an optical fibre connection (FO) or for a copper connection
(CAT7), depending on the version ordered !
In the case of an optical fibre connection the following cable is recommended:
Multi-mode (MM): 50 µm core cross section and 125 µm external cross section
Single mode (SM): 9 µm core cross section and 125 µm external cross section
Data cable lengths:
Optical fibre MM up to 500 m (1,640.42 ft) via a 50 / 125 µm optical fibre cable, up to 300 m (984.25 ft) via 62.5 /
125 μm optical fibre cable
Optical fibre SM up to 10,000 m (32,808.40 ft) via a 9 / 125 µm optical fibre cable
Copper (TX) up to 150 m (492.13 ft) via CAT7 installation cable AWG22
*4 Colour coding acc. to EIA/TIA T568B
Recommended cable length for USB, RS-232 and Audio max. 3 m (9.84 ft)
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 19 of 28
KVM units Connections
11.4 Connection diagram KVM-DVI3
11.4.1 KVM-DVI3 data connection to 6x7 unit
The SERIES 600 HMI device is connected to the KVM transmission unit via an Ethernet connection which can consist of copper (Tx) or optical fibre (MM / SM) - depending on the version ordered.
11.4.1.1 Ethernet copper (Tx) connection
11.4.1.1.1 Terminal assignment copper (Tx) connection
Diagram of cable connection between the 6x7 HMI device and the KVM transmission unit DVI3; colour coding according to EIA/TIA T568B.
View / assignment of the RJ45 plug:
Pin 1
NOTICE
Page 20 of 28
Please note:
The wire pairs must be twisted right up to the terminals of the 6x7
HMI device !
Keep the cable wires as short as possible.
Ensure that the shielding of the cable covers a wide area.
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Connections
11.4.1.1.2 LED function copper (Tx) connection
The LEDs for the state of the data connection of the Ethernet copper connection are located at the RJ45 socket.
LED status
On LED (colour)
Yellow
Green
Off
No voltage at
KVM-DVI3
No DVI / VGA signal
Flashing
Data connection interrupted
Activity at USB connection
11.4.1.2 Ethernet optical fibre (MM / SM) connection
Data connection on
DVI / VGA signal exists
Flip both optical fibre cables at one end so that the Tx signal is connected to the Rx signal, and the Rx signal to the Tx signal.
11.4.2 KVM-DVI3 connection to the host PC
Displaying the screen content and to operating the host PC require signal cables for the video, mouse and keyboard signals in addition to the power connection of the KVM transmission unit.
Use the DVI / VGA IN socket for the video signal of the host PC.
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 21 of 28
KVM units Connections
If the host computer has no DVI video signal, the KVM transmission unit can also be connected via a VGA video signal and cable. In this case, however, each host PC resolution used requires a video calibration of the KVM transmission unit.
A VGA-DVI adapter is required because the KVM transmission unit only has a DVI connector.
11.4.3 Local display of the host PC at the KVM-DVI3
If a local display of the host PC at the KVM transmission unit is required, a screen needs to be connected to the DVI / VGA OUT socket of the transmission unit.
Page 22 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Maintenance
12 Maintenance
Because the transmission of the devices remains reliable and stable over long periods of time, regular adjustments are not required.
System maintenance should focus on the following: a. Housing damage b. All cables and lines are properly connected and undamaged
13 Troubleshooting
Devices operated in hazardous areas must not be modified. Repairs may only be carried out by qualified, authorized staff specially trained for this purpose.
NOTICE
Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and
– if requested – have been authorized by the manufacturer.
13.1 Repairs / hazardous substances
An error description must be enclosed with any units returned to R. STAHL HMI Systems GmbH for repairs.
Remove all material residues. Please pay particular attention to the seal grooves and slits where material residues may be lodged. We have to ask you not to return a unit if you are unable to completely remove any hazardous substances. We shall bill you for any costs arising from insufficiently cleaned units, such as disposal or damage to persons (chemical burns, etc.).
14 Disposal
Disposal of packaging and used parts is subject to regulations valid in whichever country the device has been installed.
The disposal of devices sold after August 13th, 2005, and installed in countries under the jurisdiction of the EU is governed by directive (amendment) 2012/19/EU on waste electrical and electronic equipment (WEEE). Under this directive, operator interfaces are listed in category 9
(monitoring and control instruments).
We shall take back our devices according to our General Terms and Conditions.
14.1 RoHS directive 2011/65/EC
The revised version of the RoHS (restriction of hazardous substances) 2002/95/EC directive, directive 2011/65/EC, extends its area of application to all electric and electronic products.
The KVM units (category 9
– monitoring and controlling devices) conform with the requirements from RoHS directive 2011/65/EU, dated 03.01.2013.
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 23 of 28
KVM units
15 Declaration of EC conformity
Declaration of EC conformity
Page 24 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
KVM units Declaration of EC conformity
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017 Page 25 of 28
KVM units Release notes
16 Release notes
The chapter entitled "Release Notes" contains all the changes made in every version of the operating instructions.
Version 01.00.00
Original version of the operating instructions
Version 01.00.01
Changes to the preface
Inclusion of KGS certification for T-Ex-KVM-DVI3 (6x7-KVM-DVI3)
Inclusion of KCC certification for T-Ex-KVM-DVI3 (6x7-KVM-DVI3)
Inclusion of DVI3 images
Improvements to section entitled "Connections" and "DVM with DVI3"
Inclusion of section "Notes on DVI3"
Inclusion of section entitled "Connection diagrams KVM-DVI3"
Text and layout changes
Inclusion of "Notes on DVI2 and DVI3", "USB chip sets"
Version 01.00.02
Changing of KVM units name, now without 6x7
Deletion of section "Document created with all due care" and "No liability in case of errors"
Renaming HMI devices into SERIES 600 KVM-Systems
Inclusion of chapter "specific markings"
Changing of all markings according to the new definition
Deletion of sentence "In case of discrepancies the original BMP applies" in the preface
Addition of values of the imperial measurement systems
Adaption of section "Disposal" to the actual WEEE and ROHS directive
Text and layout changes
Version 01.00.03
Change of address
Changes to section "Disclaimer"
Addition of Warning "High Temperature" in section "Warnings"
Changing Conformity to standards
Adaption section "RoHS directive" with device conformity
Renew declaration of EC conformity
Layout and formal corrections
Page 26 of 28
R. STAHL HMI Systems GmbH / OI_KVM_units_en_V_01_00_03.doc / 28.06.2017
R. STAHL HMI Systems GmbH
Adolf-Grimme-Allee 8
D 50829 Köln
Phone: (switchboard) +49 (0) 221 76 806 - 1000
(hotline) - 5000
Fax:
E-mail: (switchboard) [email protected]
- 4100
(hotline) [email protected] www.stahl.de
www.stahl-hmi.de

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Classic point-to-point data connection
- VGA / DVI or USB / PS2 data transmission
- Copper or optical fibre connection
- Distances up to 10,000 m (32,808.40 ft)
- Digital data transfer
- KVM DVI1, DVI2 and DVI3 transmission technologies