VRV - Choose your Daikin Business portal

VRV - Choose your Daikin Business portal
HOTELS HOT WATER TEMPERATURE
OFFICE
RESTAURANTS
VENTILATION
SCHOOLS
HEATING
DESIGN BANKS
SHOP
Commercial RESTAURANTS
BANKS EFFICIENCY HEATING HOT WATER
HEATING
Solutions
CINEMA HEATING
BANKS
OFFICE
HUMIDIFICATION
AIR
VRV
COOLING
COOLING
HOTELS
COMFORT COOLING
COMFORT
catalogue
2014
MIN RUNNING COSTS
MAX FLEXIBILITY
FAST INSTALLATION
PERFECT COMFORT
Daikin
The perfect working environment is essential for all businesses. From supermarkets
to offices, from public buildings to hotels, from restaurants to shops it is essential that
the quality of the air is optimized at all times – but no space is used in exactly the same way
and that calls for flexible, tailored and economic solutions.
Daikin, Europe’s leading manufacturer and global N°1 in HVAC-R equipment, understands
this and our ‘total solution’ concept is built around customized solutions for individual
clients. Whether air conditioning, heating, ventilation, air curtains, hot water, refrigeration
or controls, Daikin has the units, the experience and the solution for you.
http://http://www.daikineurope.com/commercial/
Office
Supermarket
Hotel
Store
& shop
Public
building
Restaurant
2
Technical
Sport & Leisure
The VRV air conditioning system is the world’s first individual air conditioning system
with variable refrigerant flow control and was commercialized by Daikin in 1982.
VRV is the trademark of Daikin Industries Ltd., which is derived from the technology
we call ‘Variable Refrigerant Volume’.
European design
Over the years, the Daikin VRV systems have been designed with European taste in mind, optimised for the European climate
and manufactured in Europe for Europe. As the market leaders, Daikin understands the European market.
Setting the standard
Daikin’s continuous development of the VRV air conditioning system means it has always been and will always continue as
the benchmark standard for European air conditioning systems. The VRV VI is currently setting challenging new standards for
seasonal efficiency, optimised climate control and ease of installation.
A total solution
The Daikin VRV Total Solution service provides a single point of contact for the design and maintenance of each integrated
climate control system. By making a careful choice from our modularised units the right mix of equipment and technology
can be selected to ensure the optimal balance of temperature, humidity and air freshness for the perfect comfort zone while
delivering maximum energy efficiency, minimum operating costs and reduced CO2 emissions.
3
VRV
VRV
The original
Why choose VRV?
Low operating costs
Our latest equipment is designed to optimise performance of the total system, automatically, every minute of the day.
This includes highly efficiency outdoor units, indoor units with intelligent sensors, heat recovery technology, smart energy
management controls and much more.
According to the Franklin + Andrews, one of the world’s leading construction economists, running costs for VRV heat recovery
systems compare highly favourably with a 2 or 4 pipe fan coil system. Running costs per m2 Gross Floor Area of a fan coil system
can be 40 to 72% higher compared to a VRV heat recovery system.
A VRV system is more space efficient than a chiller too, because it requires much less plant space. For example,
Franklin + Andrews estimates that VRV system could take up 29% less plant space than a chiller system. And in a highly
competitive market place, offering the most flexible and efficient use of office space can be a real deal breaker.
Personal comfort for tenants
When viewed from the perspective of the occupants of a building, it is the comfort level provided by the climate control system
that is the most important and so the temperature has to be right, there has to be enough fresh air with the correct humidity
level and the sound level has to be minimized.
Our VRV system addresses all of these requirements and provides individual control where possible. Sound levels of our
indoor units can be as low as 19 dBA. Futhermore VRV IV continues to provide heating, even when in defrost mode, providing
the answer to any perceived disadvatages of using a heat pump for monovalent heating. While in cooling mode it eliminates
any cold draught thanks to higher outblow temperatures.
Meeting tomorrow’s legislation today
VRV also meets the requirements of the Energyrelated Performance Directive and has been designed for seasonal efficiency
with future legislative requirements in mind.
Furthermore the VRV provides greater flexibility to meet current and future client requirements, because the system can be
designed, built and commissioned zone by zone and tailored to the needs of each building tenant throughout a phased
refurbishment programme.
4
VRV
Precise zone control
to suit building occupancy
Each floor – even each room – can be individually controlled to maximise energy efficiency and prevent energy waste.
This versatility makes VRV ideal for buildings with multiple tenants, which may have vacant areas and variable periods of high
and low usage.
Modular approach gives
greater flexibility
VRV’s modular approach provides greater flexibility to balance heat loads in different parts of the building. VRV also offers
extended piping lengths so the system can be designed flexibly to suit buildings of many different sizes and shapes.
Reliability you can depend on
Of course, ensuring lower running costs depends on system reliability and efficiency over its entire lifetime. So it’s reassuring to
know that Daikin has an unparalleled reputation for quality, reliability and after sales service.
5
The VRV total solution
Many buildings today typically
operate quite separate systems for
heating, cooling, refrigeration and
hot water. As a result, a huge amount
of energy is wasted. To provide
a much more efficient alternative,
VRV technology has been developed
into a total solution managing up to
50% of a buildings energy consumption
giving large potential to cost saving.
Manage up to 50%
of your building’s energy consumption
Water heating
Other
Space heating
Office
equipment
Integrate
third party
equipment
Lighting
Space cooling
Ventilation
Source: EIA; Commercial buildings Energy
consumption survey
6
For hotels,
offices, retail,
home, ...
Heating & cooling
Intelligent control systems
22
•
•
• Mini BMS with integration of Daikin and third party
equipment
• Integration with intelligent control solutions with
energy management tools to reduce running costs
Combine VRV indoor units with stylish indoor units
in one system.
New round flow cassette sets the standard for
efficiency and comfort.
Low temperature hydrobox
for highly efficient space
heating through
•
•
•
•
Biddle air curtain
Underfloor heating
Low temperature radiators
Heat pump convector
Hot water from 25 to 45°C
• A highly efficient solution for doorway climate
separation
Ventilation
High temperature hydrobox* for efficient
hot water production for •
•
•
•
Showers
Sinks
Tapwater for cleaning
Hot water from 25 to 80°C
• Combined fresh air treatment and air conditioning
*only for connection to VRV heat recovery
7
SOLUTIONS
One system,
multiple
applications
Hospitality
with economy
A hotel’s reputation depends on how welcome and comfortable guests feel during their stay.
Yet at the same time, hotel owners must maintain complete control of their operation costs and energy
consumption.
22
Intelligent hotel
room controller
Concealed unit
Especially developed for small,
well-insulated rooms such as bedrooms
Puts the hotel owner in
full control of the energy use
Hot water
Centralised control
Heating water with renewable energy
Smart energy management
8
SOLUTIONS
Efficiency in
the workplace
Efficient building and facilities management are key to minimising operational costs
22
Fully flat cassette
Fresh air
Design & Genius in one
A healthier office atmosphere
Centralised control
Hot water
Complete Daikin package
for office building management
Cutting the cost of hot water
9
Reducing
retail costs
In the current commercial environment, retailers are under pressure to reduce both store development
and running costs. Legislation adds further financial pressure with different energy efficient schemes.
Therefore affordable, energy efficient solutions are vital to minimise lifetime costs, while ensuring
compliance with the latest regulations.
22
Round flow cassette
with auto cleaning panel
50% energy saving compared
to standard cassettes
User-friendly control
Biddle air curtain
Create a comfortable environment for customers
Highly efficient solutions
to combat the issue of climate
separation across your doorway
10
SOLUTIONS
Residential solutions
There is no place like home.
22
Daikin Emura
Remarkable blend of iconic
design and functionality
Did you know that…
22
Nexura
Combines the feel of a radiator
with the comfort and efficiency
of a heat pump
… when you opt for a Daikin air conditioner, you are also
thinking of the environment?
When we produce your air conditioner, we do our utmost to
recycle, reduce waste and use renewable energy.
11
What is new?
VRV IV heat recovery – REYQ-T
360° efficiency
p44
›› Improved operational efficiency:
·· Improved efficiency during heat recovery mode with 15%
·· Free heating or hot water by recovering heat from areas requiring cooling
·· Optimal comfort for everybody by simultaneous
·· cooling spaces while heating others
›› Improved design efficiency:
·· Integrated climate control covering all thermal loads in the building
·· Free combination of outdoor units, single and multi BS boxes
·· Unique range of single and multi BS boxes
›› Improved installation efficiency:
·· Fully redesigned multi BS boxes, smaller and up to 70% lighter
·· No limit on number of unused ports
·· Connect indoor units up to 28kW to a single and multi BS box
Integrating VRV IV technologies on
the full outdoor unit range
›› Replacement VRV IV heat recovery - RXYQQ-T
·· VRV IV standards: Variable Refrigerant Temperature, Continuous heating,
VRV configurator & 7 segment display
·· VRV IV technologies
·· Covers all thermal needs of a building: hot water (LT & HT hydrobox),
ventilation, air handling unit and Biddle air curtains
·· ‘Free’ heating and hot water by recovering heat from areas requiring cooling
·· The perfect personal comfort for guests/tenants via simultaneous cooling
and heating
·· Unique range of single and multi BS boxes
›› Water cooled VRV IV - RWEYQ-T
·· VRV IV standards: Variable Refrigerant Temperature, VRV configurator
& 7 segment display
·· Covers all thermal needs of a building: hot water (LT hydrobox), ventilation,
air handling unit and Biddle air curtains
·· Unified range for standard and geothermal series simplifies stock
·· Variable Water Flow control of water pump increases flexibility
and control
12
p66 / p72
Daikin Emura - FTXG-LW/S
p100
Heat reclaim ventilation - VAM and VKM
··
··
··
··
··
WATH’S NEW
·· Unique design. Designed in Europe for Europe.
·· Improved comfort thanks to 2-area intelligent eye, 3D air flow, sound levels down to 19dBA
·· Connectable to VRV IV and VRVIII-S heat pump
p118
High energy efficiency with DC fan motors
Optional CO2 sensor saves energy while improving indoor air quality
Optional medium (M6) and fine (F7, F8) dust filters for VAM-FB
Shorter installation time thanks to easy adjustment of nominal air flow rate
Total fresh air solution with optional supply of electrical heater
(VAM-FA/FB)
Plug & play connection to Daikin Air Handling Units
p124
·· Complete plug & play solution including AHU, ERQ or VRV condensing unit
and all unit control (EKEQ, EKEX, DDC controller), factory mounted
and configured
·· Used when the commercial ventilation range cannot satisfy the ventilation
requirement (up to 140,000 m³/h)
·· High efficiency
·· High comfort levels thanks to rapid response of ERQ and VRV to
temperature fluctuations
Simplified wired remote control for hotel applications p135
·· Symbol driven interface for intuitive control
·· Contemporary design
·· Change set point automatically when guests leaves the room or opens the
window, saving energy
·· Meets all the guests needs because every room is individually controlled
- DCM601A51
·· Cost competitive mini BMS
·· Cross-pillar integration of Daikin products (VRV hydroboxes,
air curtains, AHU, refrigeration indoors, Chillers, …)
·· Integration third party equipement via WAGO and BACnet
13
p138
Our references
Porta fira
Hotel santos porta fira
“This project reinforces Daikin's position
as a leader in the air conditioning of
large-scale structures, able to provide
solutions that stand out not only for
their accuracy and reliability, but also
for their energy efficiency.”
74 outdoor units (60 x VRV heat recovery outdoor units)
controlled via Intelligent manager,
664 indoor units,
2 x air cooled chillers (EWAD 600 BJYNN/Q)
The Range
Super store
“We were very happy to work with Daikin UK to incorporate one of the latest
fully integrated renewable systems that would provide heating, hot water, and
air conditioning, allowing The Range at Warrington to have a fully controllable
system with operation flexibility according to requirements.”
Brad Hurter, CDS Group
The Range, UK
7 x VRV IV heat pump with continuous heating,
71 round flow cassettes,
RTD control,
Intelligent Touch Manager
14
the best solution?
Heat Pump
VRV IV heat pump
››
››
››
››
Covers all thermal needs of a building: hot water (LT hydrobox), ventilation, air handling unit
and Biddle air curtains
Connectable to stylish indoor units (Daikin Emura, Nexura)
VRV IV standards: Variable Refrigerant Temperature, Continuous heating, VRV configurator
& 7 segment display
VRV IV technologies
Other VRV heat pumps
VRVIII-S
››
››
››
VRVIII-C
optimised for heating
Especially designed
for small capacities
Space saving design
Either connect VRV or
stylish indoor units:
Daikin Emura, Nexura…
››
Developed for heating
operation at low ambient
conditions.
››
Extended operation range
for heating down to -25°C
Stable heating capacity
and high efficiencies at low
ambient temperatures
››
Heat Recovery
››
››
››
››
››
››
REPLACEMENT
VRV Classic
››
For smaller projects
with standard cooling &
heating requirements
››
Connectable to all VRV
indoor units, controls and
ventilation
Covers all thermal needs of a building: hot water (LT & HT hydrobox),
ventilation, air handling unit and Biddle air curtains
‘Free’ heating and hot water by recovering heat from areas requiring cooling
The perfect personal comfort for guests/tenants via simultaneous cooling and heating
Unique range of single and multi BS boxes
VRV IV standards: Variable Refrigerant Temperature,
Continuous heating, VRV configurator & 7 segment display
VRV IV technologies
››
Cost-effective upgrade for R-22 systems, which cannot be serviced
and maintained anymore after 01/01/2015
››
››
››
››
››
››
Fast replacement
Up to 81% more efficient than an R-22 system
VRV IV standards: Variable Refrigerant Temperature,
VRV configurator & 7 segment display
VRV IV technologies
Connectable to ventilation, air handling units and Biddle air curtains
Available in heat recovery and heat pump
››
››
››
Allows heat recovery within the total building, thanks to the storage of energy in the water circuit.
Compact design and stacked configuration possible.
Suitable for multi-storey and large buildings because of the hardly unlimited possibilities of water piping.
››
››
››
Unified range for standard and geothermal series simplifies stock
Variable Water Flow control of water pump increases flexibility and control
VRV IV standards: Variable Refrigerant Temperature,
VRV configurator & 7 segment display
Covers all thermal needs of a building: hot water
(LT hydrobox), ventilation, air handling unit and Biddle air curtains
››
15
PORTFOLIO
Which VRV outdoor system
offers me
Portfolio
Outdoor unit range
Type
Product name
HEAT PUMP
System
4
5
6
8
10
12
13
14
16
18
20
RYYQ-T
Heat pump with
continuous heating
*1
*1
*1
RXYQ-T
Heat pump without
continuous heating
*1
*1
*1
*1
*1
22
AIR COOLED
RXYSQ-P8V1 (Single phase)
RXYSQ-P8Y1 (Three phase)
RTSYQ-PA
Heat pump
optimised for heating
RXYCQ-A
REYQ-T
new
*1
*1
*1
HEAT RECOVERY
REYQ-P8/P9
Small footprint combination
REYHQ-P
High COP combination
REYAQ-P
System
HEAT PUMP
HEAT RECOVERY
WATER
COOLED
for connection
with heating only hydrobox
RWEYQ-T
Type
new
Product name
4
VRVIV-Q - H/P
HEAT PUMP
HEAT RECOVERY -
RXYQQ-T
REPLACEMENT VRV
AIR COOLED
new
8
10
280
12
13
360
14
16
18
20
22
460
500
540
636
*1
RQCEQ-P
VRVIII-Q - H/R
Single unit
Multi combination
1
5
140
Capacity class
Not a standard combination (free combination)
16
*1
*1
: component is connectable
x : component is not connectable
PORTFOLIO
Not all components are connectable at
the same time to one outdoor unit.
Refer to the engineering databook for more
information.
22
Capacity (HP)
28
30
32
34
36
38
40
42
44
46
48
50
52
54
Air
Hydrobox
curtain connection
Control
systems
    

 x   
    

 x   
   x 

x
x   
 x   

x
x   
 x   x
x
x
x   
 x   

    
 x   

x
x   
 x   

x
x   
 x   

x    
 x   

 x   
 x   

x
x   
 x   

x
x   
Low temperature hydrobox for VRV
26
Ventilation
High temperature hydrobox for VRV
24
Indoor
units
Capacity (HP)
42
44
46
48
50
52
54
17
Network solutions (such as DCS6*/DAM/DMS)
40
Individual control (such as BRC)
848
38
Centralised control (such as DCS3*/DST)
816
36
Biddle Air curtain for VRV (CYV)
744
34
AHU connection kit (such as EKEXV)
712
32
Heat Reclaim ventilation (such as VAM)
30
Fresh air indoor units (such as FXMQ-MF)
28
VRV type indoor units (such as FXSQ)
26
Residential type indoor units (such as Daikin Emura)
24
Indoor unit range
With 20 different indoor unit types and a range of 14 different capacities available, VRV indoor units fit
rooms of any size or shape, tailored to the needs of the building owner.
Capacity
15
20
25
32
40
50
63
71
Cooling capacity (kW)1
1.7
2.2
2.8
3.6
4.5
5.6
7.1
Heating capacity (kW)2
1.9
2.5
3.2
4.0
5.0
6.3
8.0
FLOOR STANDING
CEILING
SUSPENDED
WALL
MOUNTED
CONCEALED CEILING
CEILING MOUNTED CASSETTE
Type
Model
Product name
Round flow cassette
autocleaning function3
Presence & floor sensor3
FXFQ-A
Fully flat cassette
Presence & floor sensor3
FXZQ-A
2-way blow
ceiling mounted cassette
FXCQ-A
Ceiling mounted
corner cassette
FXKQ-MA
Small concealed ceiling unit
FXDQ-M9
Slim concealed ceiling unit
FXDQ-A
Concealed ceiling unit
with inverter driven fan
80
100
125
140
200
250
8.0
9.0
11.2
14.0
16.0
22.4
28.0
9.0
10.0
12.5
16.0
18.0
25.0
31.5
FXSQ-P
Concealed ceiling unit
with inverter driven fan
FXMQ-P7
Large concealed
ceiling unit
FXMQ-MA4
Wall mounted unit
FXAQ-P
Ceiling suspended unit
FXHQ-A
4-way blow ceiling
suspended unit
FXUQ-A
Floor standing unit
FXLQ-P
Concealed
floor standing unit
FXNQ-P
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m
3
Optional
4
Not connectable to VRV III-S
1
2
18
PORTFOLIO
Connectable
outdoor unit
Capacity
CONCEALED CEILING
CEILING MOUNTED
CASSETTE
Type
Round flow cassette
(incl. autocleaning function1)
FCQG-F

FFQ-C

Fully flat cassette
WALL MOUNTED
CEILING
SUSPENDED
FLOOR STANDING
15
20
25
35
42
50
60
71
Small concealed ceiling unit FDBQ-B

Slim concealed ceiling unit FDXS-F(9)

Concealed ceiling unit
with inverter driven fan

FBQ-C8
FTXG-LW/
LS


Wall mounted unit
CTXS-K
FTXS-K


Wall mounted unit
FTXS-G


Ceiling suspended unit
FHQ-C
Wall mounted unit

FVXG-K


Floor standing unit
FVXS-F


Flexi type unit
FLXS-B(9)


Nexura floor standing unit
1
RXYSQ-P8V1
RXYSQ-P8Y1
Product
name
Daikin Emura
new
RYYQ-T
RXYQ-T
Model
Decoration panel BYCQ140CG + BRC1E51A needed
19
Ventilation range
Humidification: optimise the balance
between indoor and outdoor humidity
Ventilation: provision of fresh air
Heat recovery: recovers heat and moisture
from the outgoing air to maximise comfort &
efficiency
Air processing: heats or cools
incoming fresh air maximising
comfort and minimizing the load on
the air conditioning installation
Filtration: Removes dust, pollution and
odours from the air
Air flow rate (m3/h)
Type
name
VAM-FA/FB
HEAT
RECLAIM
VENTILATION
OUTDOOR
AIR PROCESSING
UNIT 1
VKM-GB
2
3
0
200
400
600
800
1,000 1,500 2,000 4,000 6,000 8,000
›› Ventila­tion
›› Heat recovery
›› Ventila­tion
›› Heat recovery
›› Air processing
VKM-GBM
››
››
››
››
FXMQ-MF
›› Ventila­tion
›› Air processing
AIR HANDLING DX total fresh air
UNITS
package
1
Components
of indoor air quality
››
››
››
››
››
Ventila­tion
Heat recovery
Air processing
Humidification
Ventila­tion
Heat recovery
Air processing
Humidification
Filtration
(3)
Not connectable to VRVIII-S (RXYSQ-PAV, RXYSQ-PAY)
Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m³/h
Daikin AHU connected to Daikin chiller solution
20
124,000
Biddle air curtain range
Product Name
BIDDLE AIR CURTAIN FREE HANGING
CYV S/M/L-DK-F
BIDDLE AIR CURTAIN CASSETTE
CYV S/M/L-DK-C
BIDDLE AIR CURTAIN RECESSED
CYV S/M/L-DK-R
PORTFOLIO
Type
Door height (m)
4
3.0m
3
2.75m
2.5m
2.3m
2.4m
2.5m
2.3m
2.15m
2.0m
2
1
S
M
L
Favourable
ex: covered shopping mall or
revolving door entrance
S
M
L
S
Normal
ex: little direct wind, no
opposite open doors, building
with ground floor only
M
L
Unfavourable
ex: location at a corner or
square, multiple floors
and / or open stairwell
Installation condition
Hydrobox range
Capacity
Product name
Leaving water
temperature range
LOW TEMPERATURE
HYDROBOX
HXY-A
5°C - 45°C
HIGH TEMPERATURE
HYDROBOX
HXHD-A
25°C - 80°C
Type
80
125
Network solutions
ITC
ITM
Maximum indoor unit groups
ACNSS connection Air Conditionning Network
Service System
Free cooling
Sliding temperature
Pre-cool/heat
Interlock
Other
HTTP option
+
Web access & control
+
PPD
Visualisation
Options
History (operation, malfunction…)
Malfunction code
Filter status
Forced off
+
Basic control functions:
ON/OFF status, operation mode, set point temp.
+
Timer extension
Weekly schedule & special day pattern
Monitoring
Automatic changeover
Setback
Temperature limitation
(3)
Refrigerant containment check
(3)
Control
Basic control functions:on/off, temp, setting,
air flow sttings
3rd party equipment integration
Touch screen
Integration
Mini BMS for heating, air conditioning
applied systems & refrigeration units
Layout screen
Screen
64
Std
+
2560
DMS-IF 1
64
BACNET 2
4x64
1
Gateway for Lonworks networks 2
Gateway for BACnet networks
3
BACnet and WAGO
21
Our references
Labo LADR
Medical laboratory
4 x VRV heat recovery outdoor units
(1 x REYQ42P8; 1 x REYQ44P8 1 x REYQ46P8; 1 x REYQ48P8)
2 x Sky Air outdoor units (RZQ200C)
4 x Sky Air indoor units (FHQ100B)
Ventilation via air handling units
Control via Intelligent Touch Controller
Total building approach using
waste heat for offices and allowing
individual control
Sky Tower
“The high quality of presales service
provided by the Daikin sales team,
the proposed solution with
proven reliability from past references and
extensive research to offer the best solution
convinced the customer.”
Office and residential project
VRV: 8 x VRV III heat recovery outdoor units (8 x REMHQ12P8)
151 x VRV III heat pump outdoor units
(57 x RXYQ18P9; 1 x RXYQ8P9; 1 x RXYQ10P9; 5 x RXYQ12P9;
2 x RXYQ16P9; 21 x RXYSQ4P8Y1; 2 x RXYSQ5P8Y1;
2 x RXYSQ6P8Y1)
653 x VRV indoor units
Ventilation: 10 x ERQ250AW1; 154 x VAM500FA; 90 x VAM250FA;
42 x VAM800FA; 12 x VAM600FA
22
Advanced software tools for system design assistance, enabling you to select & sell the product that fits
your customer needs
Sales supporting apps
Daikin E-data app
contains an overview of all Daikin Europe N.V. products that are
available in your country, in your own language. You can easily
browse the products to find the engineering data you need.
Seasonal Solutions Simulator
With this software tool you can simulate the seasonal efficiency, the
annual power consumption and CO2 emission for a given climate,
load profile (cooling, heating, heat recovery, covalent, bivalent…)
and (combination of ) system(s). With its intuitive and graphical
appealing interface, a simulation can be made in a matter of
minutes. The solution basket system enables you to compare the
results of several system configurations.
Selection software
Xpress
Xpress is a flexible design software to optimise equipment selection
in cost and it enables you to make a high efficient building design.
VRV Pro
VRV pro is a true VRV design tool. The program enables VRV air
conditioning systems to be engineered in a precise and economical
way, taking into account the complex piping rules. Moreover, it
ensures optimum operating cycles and maximum energy efficiency.
In this way, it gives the designer the possibility to make accurate
selections and get competitive quotations for each project.
For a complete line-up of tools & downloads, visit:
http://extranet.daikineurope.com/en/software/default.jsp
or contact your local representative
23
PORTFOLIO
Tools
VRV IV =
3 revolutionary standards
• Variable refrigerant temperature
• Continuous comfort during defrost
• VRV configurator
++ VRV IV technologies
++ Integrated climate control
24
Customize your VRV for best seasonal efficiency & comfort.
Thanks to its revolutionary varialble refrigerant temperatue technology, VRV IV continuously adjusts
the refrigerant temperature to the actual temperature and capacity needed, thus providing optimal
seasonal efficiency at all times.
• Improved seasonal efficiency with 28%
• Weather dependent
• Customer comfort is assured with automatic adjustement of refrigerant temperature leading
to higher outblow temperatures (avoiding cold draft)
Different modes:
The system can be easily customised via preset modes. With the modes you choose to optimise the system towards your required
balance between comfort and efficiency
Automatic mode
High sensible mode
(Default setting on VRV IV)
Quick reaction
speed
Top
efficiency
The perfect balance :
Top efficiency throughout most of the year.
Quick reaction speed on the hottest days
Basic mode (current VRF standard)
Quick reaction
Top
speed
efficiency
Year round top efficiency
Quick reaction
Top
speed
efficiency
Quick reaction to peak load,
to maintain set point
Effect of preset modes on efficiency and reaction speed:
Automatic mode
(Default setting on VRV IV)
High sensible mode
Basic mode (current VRF standard)
Load
Load
Load
Refrigerant volume (VRV)
Refrigerant volume (VRV)
Refrigerant volume (VRV)
Refrigerant temperature (VRT)
Refrigerant temperature (VRT)
Refrigerant temperature (VRT)
Efficiency
Efficiency
Efficiency
Unique VRT automatic mode leads to 28% increase
in seasonal efficiency
In automatic mode the system will go for maximum efficiency
throughout most of the year and for quick reaction speed on the
hottest days, ensuring comfort at all times while still resulting in an
increased seasonal efficiency up to 28%.
Automatic mode
Quick reaction
speed
(Default setting on VRV IV)
Top
efficiency
The perfect balance : Maximum efficiency throughout most of the year.
Quick reaction speed on the hottest days
25
VRV IV
TECHNOLOGIES
1. Variable refrigerant
temperature
2. Continuous heating
during defrost
VRV IV continues to provide heating even when in defrost mode, providing an answer to any perceived
disadvantages of specifying a heat pump for monovalent heating.
• Indoor comfort not affected either via the unique heat accumulating element or alternate defrost
• The best alternative to traditional heating systems
Room
temperature
Heat pumps are known for their high energy efficiency in heating,
but they accumulate ice during heating operation and this must
be melted periodically using a defrost function that reverses the
refrigeration cycle. This causes a temporary temperature drop and
reduced comfort levels inside the building.
Defrosting can take over 10 minutes (depending on the size of the
system) and occurs most frequently between -7 and +7°C when
there is most humidity in the air, which freezes to the coil, and this
has a significant impact on the perceived indoor comfort levels.
new
VRV IV
VRF benchmark
The VRV IV has changed the heating pardigm by providing heat
even during defrost operation thus eliminating the temperature
drop inside and providing comfort at all times.
How does it work?
Heat accumulating element
A unique heat-accumulating element, based upon phase change
materials, provides the energy to defrost the outdoor unit. The
energy needed for defrosting is stored in the element during
normal heating operation.
The outdoor unit coil
is defrosted …
… with the energy stored
in the heat accumulating
element …
… while indoors
a comfortable temperature
is maintained.
Alternate defrost
On all our multi model combinations only 1 outdoor coil is defrosted
at a time, ensuring continuous comfort during the whole process.
the outdoor unit coil
is defrosted …
… one at the time …
… so indoors a comfortable
temperature is maintained
26
ΔT
Time
3.VRV
configurator software
• Graphical interface
• Manage systems over multiple sites in exactly the same way
• Retrieve initial settings
Simplified commissioning
The VRV configurator is an advanced software solution that allows for easy system configuration and commissioning:
• less time is required on the roof configuring the outdoor unit
• multiple systems at different sites can be managed in exactly the same way, thus offering simplified commissioning forkey accounts
• initial settings on the outdoor unit can be easily retrieved.
User friendly
interface instead of
push buttons
Simplified
commissioning
Retrieve initial
system settings
Simplified servicing
Outdoor unit display for quick on-site settings and easy read out
of errors together with the indication of service parameters for
checking basic functions.
• easy-to-read error report
• clear menu indicating quick and easy on-site settings
• indication of basic service parameters to quickly check
basic functions: high pressure, low pressure, frequency
ans operation time history of compressors, temperature of
discharge/suction pipe.
3 digit 7-segment display
27
VRV IV
TECHNOLOGIES
Software for simplified commissioning, configuration and customisation
VRV IV
technologies
4
3
2
1
1
Newly developed compressor
Full inverter
• Enabling Variable Refrigerant Temperature and low start-up currents
• Stepless capacity control
Reluctance brushless DC motor
• increased efficiency compared to AC motors by simultaneous using normal and
reluctance torque
• Powerful neodymium magnets efficiently generate high torque
• High pressure oil reduces thrust losses
High efficinency J-type 6-pole motor
• 50% stronger magnetic force & higher rotation efficiency
Newly developed compressor material
• Compression volume is increased with 50% thanks to a new high strenght material casted
in a semi molted state (thixocasting process)
2
new
new
compressor
material
6 pole
motor
DC motor
new
4-side heat exchanger
Up to 50% more heat exchange surface (up to 235m2) leading to 30% better efficiency
28
•
•
4
new
Gas cooled PCB
Reliable cooling as it is not influenced by ambient air temperature
Smaller switchbox for smoother air flow through the heat exchanger
VRV IV
TECHNOLOGIES
3
DC Fan Motor
Outer rotor DC motor for higher efficiency
•
Bigger diameter of the rotor results in greater force for the same magnetic field
•
Better control resulting in more fan steps to match the actual capacity
100
Daikin outer rotor
80
rotor
F
Efficiency (%)
Conventional motor
with inner rotor
DC motor efficiency
(comparison with a conventional AC motor)
rotor
60
40
AC motor
20
F
0
200300400 500600700800 9001000
Motor speed (rpm)
Sine Wave DC Inverter
Optimizing the sine wave curve, results in smoother motor rotation
and improved motor efficiency.
DC Fan Motor
The use of a DC fan motor offers substantial improvements
in operating efficiency compared to conventional AC motors,
especially during low speed rotation.
5
E-Pass Heat Exchanger
Optimization of the path layout of the heat exchanger prevents heat
transferring from the overheated gas section towards the sub cooled
liquid section - a more efficient use of the heat exchanger.
OUT 45°
OUT 45°
IN 85°C
IN 85°C
55°C
27°C
27°C
43°C
27°C
55°C
27°C
60°C
27°C
50°C
27°C
55°C
OUT 45°
OUT 45°
I-Demand Function
Power
The newly introduced current sensor minimizes the difference
between the actual power consumption and the predefined power
consumption.
consumption (KVV)
6
e-Pass
heat exchanger
Standard
heat exchanger
8:00
12:00
Time
29
16:0020:00
Benefits for
building owners
 Drastically reducing your running costs
 A long lasting investment
Precise zone control
VRV systems have low running costs because it permits each zone
to be controlled individually. That is, only those rooms that require
air conditioning will be heated or cooled, while the system can
be shut down completely in rooms where no air conditioning is
required.
ON
OFF
ON
OFF
All inverter compressors
ALL
All inverter control compressors allow to control the refrigerant
volume almost stepless. In this way the capacity perfectly
matches the different loads in every room avoiding unnecessary
energy use.
Additionally all inverter compressors also allow precise refrigerant
temperature control, automatically adapting your VRV to your
building and climate requirements, reducing runnig costs with 28%.
Smart energy management Smart energy management tools reduce running costs by
preventing energy wastage. Using the schedule function and
monitoring tools you can easily detect origins of energy waste
and track consumption to ensure it is according to plan. Our
intelligent tools maximize efficiency at all times.
Indication of where energy
saving is possible
30
ON
BENEFITS
Intelligent indoor units
The round flow cassette, Daikin’s technology flagship indoor unit, shows that intelligent indoor units lead to great savings in runnings and pays
itself back in no time!
Auto-cleaning panel
The auto-cleaning filter automatically cleans itself once a day preventing the filter gets dirty, leading up to 50% savings.
Dust can be simply removed from the unit with a vaccuum cleaner.
Test of auto cleaning panel versus normal panel
50% lower
Energy consumption (kWh)
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
energy
consumption
ly
Ju
ne
ay
M
Ju
M
ru
ar
Ap
r il
ch
y
ar
ar
Fe
b
De
Ja
ce
y
r
nu
m
be
be
r
r
m
ve
No
Oc
to
be
r
be
em
Se
pt
Au
gu
Ju
ly
st
(Test site, Wolverhampton, UK)
Auto cleaning cassette
Standard round flow cassette
with regular servicing
Presence sensor
The presence sensor adjusts the set point or switches off the unit if no persons are in the room, preventing up to 27% of unnecessary energy
use. At the same time it can detect people and direct the airflow away from them for added comfort.
Presence
sensor saves
up to 27%
Nobody in
the room
Inside temp. (°CDB)
26°
24°
Energy saved
22°
Cooling set point : 22° CDB
no presence detected for 15mins
0
.0
0
.3
31
17
16
0
.0
16
0
0
.3
.0
15
0
.3
15
14
0
.0
14
0
0
.3
13
.0
13
0
.3
12
0
0
.0
12
.3
0
.0
11
11
0
0
.3
10
.0
0
.3
10
09
09
.00
20°
Anti Corosion Treatment
Special anti corrosion treatment of the heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion.
The provision of rust proof steel sheet on the underside of the unit gives additional protection.
Up to 6 times
greater resistance
against corrosion
Performed tests:
VDA Wechseltest
Contents of 1 cycle (7 days):
›› 24 hours salt spray test SS DIN 50021
›› 96 hours humidity cycle test KFW
DIN 50017
›› 48 hours room temperature & room
humidity testing period: 5 cycles
An anti-corrosion heat exchanger
cutaway view
Hydrophilic film
Aluminium
Heat exchanger
Corrosion-resistant
Acrylic resin
Degree of
corrosion
8
7
6
5
4
3
2
1
0
Bare aluminium
1234 5
DAIKIN P.E.
Cycle
Degree of
corrosion
Kesternich test (SO2)
›› contents of 1 cycle (48 hours)
according to DIN50018 (0.21)
›› testing period : 40 cycles
10
9
8
7
6
5
4
3
2
1
0 12 34 561020
30
40 50 6070
Cycle
Duty Cycling extends operation life
The cyclical start-up sequence of multiple outdoor units systems
equalises compressor duty and extends operating life.
Sequential Start
Up to 3 outdoor units can be connected to 1 power supply and can
be turned on sequentially. This allows the number of breakers and
their capacities to remain small and simplifies wiring (for models of
10HP or less).
Only one power supply
32
BENEFITS
Our references
Edificio contenedor
de institutos
R & D building
15 x VRV IV heat pump with
continuous heating outdoor units (RYYQ-T (254hp)
123 x VRV indoor units (54 x FXSQ-P; 28 x FXHQ-MA 25
x FXZQ-A; 8 x FXAQ-P; 8 x FXLQ-P)
ventilation: 5 x ERQ-A; 5 x EKEQFCB+EV
control: via Intelligent Touch Manager
“Both from a technical and efficiency point of view, we could offer
the best solution, but, most important, the complex solution was made look easy
for the customer as he only had one point of contact for both the HVAC systems
and controls. A service only Daikin could offer.”
“Kaffee Partner chose
Daikin VRV for its efficiency,
low investment and small
footprint.”
Kaffee Partner
administration building
and storage
7 x VRV heat pump outdoor units:
(2 x RXYQ12P9; 2 x RXYQ14P9; 1 x RXYQ16P9;
1 x RXYQ22P; 1 x RXYQ8P9); 3 x ERQ250AW1;
114 x VRV indoor units: (2 x FXSQ20P; 13 x FXSQ40P; 5 x FXZQ15M9;
21 x FXZQ20M9; 26 x FXZQ25M9; 4 x FXZQ32M9; 9 x FXZQ40M9;
4 x FXZQ50M9)
33
Benefits for
end users
 Comfort guaranteed at all times
Smart Control Brings Comfort
Stable room temperature
An electronic expansion valve, using PID (Proportional Integral Differencial) control, continuously adjusts the refrigerant volume in respond to
load variations of the indoor units. The VRV system thus maintains comfortable room temperatures at a virtually constant level, without the
temperature variations typical of conventional ON/OFF control systems.
VRV SERIES
(DAIKIN indoor unit (PID controlled))
Cooling
Suction air temp.
ON/OFF controlled indoor unit (2.5HP)
Stable room temperature
Time
Note: The graph shows the data, measured in a test room assuming actual heating load. The thermostat can
control stable room temperature at ± 0.5°C from set point.
No more cold draught
Automatic or manual adjustment of refrigerant temperature leads to higher outblow temperatures which avoid the cold draught coming from
the indoor unit.
16°
Constant and high
air discharge temperature
34
Back -up Function
In the event of a compressor malfunction another compressor or outdoor unit will take over in order to maintain 8 hour interim capacity,
allowing time for maintenance or repair while comfort remains guaranteed.
BENEFITS
Single outdoor unit
with multiple compressors
Multi outdoor unit system
Low indoor unit operation sound level
Daikin indoor units have very low sound operation levels, down to 19dB(A), making them ideal for sound sensitive area’s as hotel bedrooms,
etc…
db(A)
Perceived loudness
Sound
0
Treshold of hearing
-
20
Extremely soft
Rustling leaves
40
Very soft
Quiet room
60
Moderately loud
Normal conversation
80
Very loud
City traffic noise
100
Extremely loud
Symphonic orchestra
120
Threshold of feeling
Jet taking off
19dB(A)
Daikin
indoor units
25.5dB(A)
FXZQ-A
emura
Connectable to VRV IV
and VRV III-S heat pump
Connectable to all VRV heat pumps
35
Benefits for
design offices
and consultants
 Maximum flexibility
 Meeting and exceeding legal requirements
Wide operation range
The VRV system can be installed practically anywhere. VRV outdoor units operate in cooling mode between -20°C and +46°C outdoor ambient
and between -25°C and +15.5°C in heating mode.
-20C°
46°C
-25C°
Cooling mode
Heating mode
Contact your local dealer for more information and restrictions
VRV IV example
Total piping length
Longest length actual (Equivalent)
1000m
165m (190m)
Longest length after first branch
90m1
Level difference between
indoor and outdoor units
90m1
Level difference between indoor units
30m
1 Contact your local dealer for more information and restrictions
2 In case outdoor unit is located below indoor units
36
90m piping length after first branch
1
165m Actual piping length
The long piping lengths, high level differences and small refrigerant
piping allows for a design with little limitations and leaving
maximum space for lettable space.
30m Level difference between indoor units
Flexible piping design
40m (90m1) Level difference between indoor and outdoor units
With the technical cooling function, the operation range in cooling
of the heat recovery system is extended from -5°C to -20°C 1,
making it perfect for integrating server rooms.
15.5°C
Night quiet mode
For areas where there are stringent limitations to sound levels the
outdoor unit sound level can be reduced, to meet the requirement.
Peak in the outdoor
temperature
100%
8 hrs
10 hrs
50%
Capacity* %
Load %
Operation Sound dBA
Step 1: max. - 8dB (10HP)
Step 1: 50dB
Step 2: max. - 13dB (10HP)
Step 2: 45dB
50dBA
45 dBA
Night mode STARTS
Night mode ENDS
Example for VRV IV heat pump, factory setting.
Indoor installation
The VRV optimised fan blade shape increases output and reduces
pressure loss. Together with the high ESP setting (up to 78pa), it
makes VRV outdoor units ideal for indoor installation using ducts.
ESP up to
78pa
Indoor installation leads to less piping length, lower installation
costs, increased efficiency and better visual aesthetics.
Multiple tenants, one outdoor unit The multi tenant function ensures that the entire VRV system does not
shut down when the main power supply of an indoor is switched off.
This means that the indoor unit’s main fuse can be turned off when
a part of the building is closed, is being serviced, …
operation
in holiday
in service
operation
No structural reinforcement necessary
Thanks to the vibration-free and sufficient light construction of
the outdoor units, floors do not need to be reinforced, reducing
the overall cost of the building when compared to a chiller.
max. 398kg for a 20HP unit
37
BENEFITS
Night mode
58 dBA
Benefits for
installers
 Fast installation and commissiong
 Easy servicing
Compact design
The compact design of the outdoor units is sufficient to allow them
to be taken up to the top of a building in a commercial elevator,
overcoming site transportation problem, particularly when outdoor
units need to be installed on each floor.


Phased installation
Installation of the VRV system can be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling
the air conditioning system to be commissioned and operated in stages, rather than on final completion of the project.
Installation
floor by floor
Under construction
X
X
VRV system
Top quality - Only brazed connections
All flange and flare connections inside the unit have been
replaced by brazing connections to ensure improved refrigerant
containment. Also the connection of the outdoor in the main
pipe is brazed.
Flare or flange
Brazing
38
Automatic charging & testing
Efficient use of time
Manual
1
2
3
4
Calculate extra
refrigerant volume
Connect first bottle
on VRV & start
filling process
Check on regular
times weight scale
to check weight of
refrigerant
Stop manually the VRV filling
procedure & close valves
1
2
Connect bottle
to VRV & active automatic
charging function
BENEFITS
Automatic
Push button
on the PCB
Filling procedure
stops automatically:
close valves
After charging pushing the test operation button initiates a check on the wiring, shut off valves, sensors and refrigerant volume.
If the temperature drops below 20°C* manual charging is necessary.
* 10°C for heat pump for cold regions
* Not available for VRV Classic and VRV IV W-series
Did you know …
Optimal charge = optimal efficiency
Planned installation
64 m refrigerant piping
›
10% undercharged
calculation: 2.2kg extra
refrigerant required
up to 25% capacity loss
0.5 kg
Real installation
76 m refrigerant piping
›
33% more energy use
2.7kg extra refrigerant
required in reality
Daikin Unified REFNET piping
The unified Daikin REFNET piping system is especially designed for simple installation.
Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed
to optimise refrigerant flow.
Daikin Europe N.V. advises only to use Daikin REFNET piping system.
REFNET joint
REFNET joint
Attached insulators
for REFNET joint
T-joint
39
REFNET header
Attached insulators
for REFNET header
Easy compliance to F-gas regulation
Automatic refrigerant containment check
Perform the refrigerant containment check remotely via Intelligent Touch Manager, when it is most convenient for you, preventing an on-site
visit. At the same time increase your customer satisfaction because there is no disruption to the air conditioning during business hours.
Next to remote checking, the refrigerant containment check function can also be activated on-site via a push button on the PCB.
Remotely set the time
and start the refrigerant
containment check
Connect to customer site via internet or
3G after working hours
Check the report once
the check has been done
When activating the refrigerant containment check, the unit switches into cooling mode and duplicates certain reference conditions based on memory data.
The result indicates whether or not refrigerant leakage has occurred.
The refrigerant volume of the complete system is calculated for the following data:
›› Outdoor temperature
›› Reference system temperatures
›› Reference pressure temperatures
›› Refrigerant density
›› Types and number of indoor units
Not available on VRVIII-S or in combination when one or more RA indoor units, hydroboxes, … are connected
Refrigerant Recovery Function When an indoor unit or outdoor needs to be replaced in case of malfunction the refrigerant
can be easily drained from the system, making servicing easier.
40
Easy wiring - “Super Wiring” System
Simplified wiring
››
››
››
Shared use of wiring between indoor units, outdoor units and centralised remote control
Easy retrofit of centralised remote control
Impossible to make incorrect connections thanks to non polarity wiring
Cross wiring check
The cross wiring check facility warns operatives of connection errors in inter unit wiring and piping.
Auto Address Setting Function
BENEFITS
Allows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without
the bothersome task of manually setting each address.
Cinemeerse
Large cinema
12 x VRV heat recovery 8HP outdoor units
air handling units with VAV (70,000m³/h)
connected to CO2 sensors
Installer: “I dare to assert that in a record
time (construction took only four months)
we have built the most energy efficient
cinema in The Netherlands, and even
in Europe.”
41
VRV
Outdoor
systems
Variable Refrigerant Temperature
Continuous heating (heat accumulating element)
Continuous heating ( alternate defrost)
VRV configurator
7 segment indicator
Automatic refrigerant charge
Refrigerant containment check
Night quiet mode
Manual low noise function
Connectable to stylish indoor units (Daikin Emura, Nexura)
Connectable to LT hydrobox for hot water
Connectable to HT hydrobox for hot water
Full inverter compressors
Gas cooled PCB
4 side heat exchanger
Reluctance brushless DC compressor
Sine wave DC inverter
DC fan motor
E-pass heat exchanger
I demand function
Manual demand function
42
VRV IV
Heat
recovery
VRV IV
heat pump
with continous
heating
VRV IV
heat pump
without
continous
heating
VRV III-S
p 44
p 50
p 50



VRV IV HEAT
RECOVERY
Overview of functions
VRV III-C
VRV
Classic
Replacement
VRV IV
heat pump
Replacement
VRV III
Heat
recovery
Water cooled
VRV IV
p 56
p 60
p 64
p 66
p 66
p 72














-








-












































-








-





















































-


























-








-


















43
22
Air curtain
Biddle Air curtain for VRV (CYV)
Indoor units
VRV type indoor units
Hot water
Low temperature hydrobox
High temperature hydrobox
Control systems
VRV IV
heat recovery
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
AHU connection kit
VRV IV standards:
99 7 segment indicator
99Variable refrigerant temperature
99 Refrigerant containment check
Customize your VRV for best seasonal efficiency & comfort
99 Full inverter compressors
The new standard in heating comfort
99 Gas cooled PCB
99VRV configurator
99 Night quiet mode
99 Manual low noise function
99Continuous heating
99 Automatic refrigerant charge
99 4 side heat exchanger
Software for simplified commissioning, configuration
and customisation
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 DC fan motor
99 E-pass heat exchanger
99 I demand function
99 Manual demand function
For detailed explanation of these functions refer to VRV IV technologies tab
44
More free heat
Power input Daikin
Daikin 3-pipe technology needs less energy to recover heat,
meaning significant better efficiency during heat recovery mode.
Our system can recover the heat at low condensing temperature
because it has dedicated gas, liquid and discharge pipes.
Condensing 55°C
Condensing 45°C
Pressure
Power
input
2-pipe
system
In a 2-pipe system gas and liquid travel as a mixture so the condensing
temperature needs to be higher in order to separate the mixed gas
and liquid refrigerant. The higher condensing temperature means
more energy is used to recover heat resulting in lower efficiency.
Free heat and hot water production
Until now most commercial buildings have individual systems for cooling, heating, hot water etc. leading to big energy waste.
An integrated heat recovery system reuses heat from offices, server rooms etc. to warm other areas or create hot water.
22
Extracted heat delivers
22
free hot water and heating
Cooling
Did you know …
that re-using energy by heat recovery
can lead to savings up to 10, meaning
for 1 unit of electricity? This means
huge savings in running costs and CO2
emissions.
Hot Water
COP
Heating
Ideal situation
when heating and cooling
10
8
7
6
5
4
3
2
1
02040
100
50% heating 60 80
Only cooling
Only heating
50% cooling
Improved efficiency
In heat recovery operation the VRV IV is up to 15% more efficient. In full load operation the seasonal efficiency is efficient even up to 28% better
compared to VRV III thanks to Variable Refrigerant Temperature.
Load
Improved mix mode
refrigerant control
Up to 15%
more efficient
T amb
45
VRV IV HEAT
RECOVERY
Enthalpy
N
Maximum comfort
A VRV heat recovery system allows simultaneous cooling and heating.
›› For hotel owners it means a perfect environment for guests as
they can freely choose between cooling or heating.
›› For offices it means a perfect working climate both for tenants
facing south and north.
S
More efficient due to lower pressure drop
110%
Smooth refrigerant flow
in 3-pipe system thanks to
2 smaller gas pipes leading
to higher energy efficiency
105%
100%
3-pipe
95%
90%
2-pip
R
e sys
85%
80%
VRV H/
0
Disturbed refrigerant flow
in large gas pipe on 2-pipe system
leading to bigger pressure drop
tem
50 100
m
Free combination of outdoor units
Freely combine outdoor units to optimise for small footprint, continuous heating, highest efficiency or any other combination.
Flexible piping design
90m1
Level difference between indoor
and outdoor units
90m1
Level difference between indoor units
30m
1
1 Contact your local dealer for more information and restrictions
2 In case outdoor unit is located below indoor units
46
90m maximum
Longest length after first branch
30m Level difference between indoor units
165m (190m)
40m (90m ) Level difference between indoor and outdoor units
Longest length actual (Equivalent)
1000m
165m Actual piping length
Total piping length
Fully redesigned BS boxes
Maximum design flexibility and installation speed
• Unique range of single and multi BS boxes for flexible and fast design
• Major reduction in installation time thanks to wide range, compact size and light weight multi BS boxes
Multi port: 4 – 6 – 8 – 10 – 12 – 16
BS1Q10,16,25A
•
•
•
•
•
Compact & light to install
Ideal for remote rooms as no drain piping needed
Allows integration of server rooms thanks to
technical cooling function
Connect up to 250 class unit (28kW)
Allows multi tenant applications
BS4Q14A
•
•
•
•
•
•
•
BS6,8Q14A
BS10,12Q14A
BS16Q14A
Up to 70% smaller and 66% lighter than previous range
Faster installation thanks to a reduced number of brazing points and wiring
All indoor units connectable to one BS box
Less inspection ports needed compared to installing single BS boxes
Up to 16 kW capacity available per port
Connect up to 250 class unit (28kW) by combining 2 ports
No limit on unused ports allowing phased installation
Maximum comfort at all times
Thanks to the VRV BS box, all indoor units which are not switching from cooling to
heating or vica versa continue to provide heating or cooling. This is because our
heat recovery system does not need to equalize pressure over the entire system
after a change-over.
Faster installation thanks to open connection
Time saving!
No need to cut the pipe before brazing
(for indoor units smaller or equal to 5.6 kW (50 class))
Cut and braze the pipe
(for indoor units bigger or equal to 7.1 kW (63 class))
47
VRV IV HEAT
RECOVERY
Single port
Specifications
VRV IV heat recovery - REYQ-T REYQ-T
System
Capacity range
Continuous heating
Cooling capacity Nom
Heating capacity Nom
Heating capacity Max.
Nom.
Power input - 50Hz Cooling
Nom.
Heating
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min
connection
Nom
Max
Dimensions
Unit
hxwxd
Weight
Unit
Fan
Air flow rate
Cooling Nom
Sound power level Cooling
Nom
Sound pressure level Cooling
Nom
Operation range Cooling
Min~max
Heating
Min~max
Space cooling Min~max
Water
production
Space heating Min~max
Domestic hot water
Min~max
Refrigerant
Type
Piping connection liquid
OD
gas
OD
discharge gas
OD
total piping length
system
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
REYQ-T
System
HP
kW
kW
kW
kW
kW
mm
kg
m3/min
dBA
dBA
°CDB
°CWB
°CDB
°CWB
°CWB
mm
mm
mm
m
Hz/V
A
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Capacity range
Continuous heating
Cooling capacity Nom
Heating capacity Nom
Heating capacity Max.
Nom.
Power input - 50Hz Cooling
Nom.
Heating
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min
connection
Nom
Max
Piping connection liquid
OD
gas
OD
discharge gas
OD
total piping lenght
system
Current - 50Hz
Maximum fuse amps (MFA)
OUTDOOR UNIT MODULE
Dimensions
Unit
hxwxd
Weight
Unit
Fan
Air flow rate
Sound power level Cooling
Nom
Sound pressure level Cooling
Nom
Operation range Cooling
Min~max
Heating
Min~max
Water production Space cooling
Space heating
Domestic hot water
Refrigerant
Power supply
Current - 50Hz
8
REYQ8T
Outdoor unit module 1
Outdoor unit module 2
Type
Phase/Frequency/Voltage
Maxiimum fuse amps (MFA)
HP
kW
kW
kW
kW
kW
mm
mm
mm
m
A
10
12
13
14
16
18
20
REYQ10T REMQ5T REYQ12T REYQ8T REYQ14T REYQ16T REYQ8T REYQ18T REYQ8T REYQ20T REYQ8T
REMQ5T
REMQ5T
REYQ8T
REYQ10T
REYQ12T
8
10
10
12
13
14
16
16
18
18
20
20
v
v
v
v
v
22.4
28.0
28.0
33.5
36.4
40.0
45.0
44.8
50.0
50.4
56.0
55.9
22.4
28.0
28.0
33.5
36.4
40.0
45.0
44.8
50.0
50.4
56.0
55.9
25.0
31.5
32.0
37.5
41.0
45.0
50.0
50.0
56.0
56.5
63.0
62.5
64 (1)
100
125
125
150
162.5
175
200
200
225
225
250
250
200
250
250
300
325
350
400
400
450
450
500
500
260
325
325
390
422.5
455
520
520
585
585
650
650
1685x930x765
1685x930x765
1685x1240x765
1685x1240x765
1685x1240x765
198
205
205
319
319
329
329
162
175
185
223
260
251
261
78
79
81
81
81
81
86
81
86
82
88
83
58
58
61
61
61
61
64
61
65
61
66
63
-20(2) / -5~43
-20~15.5
8~43
-20~20 / 24 (2)
-20~43
9.5
19.1
15.9
9.5
22.2
19.1
9.5
22.2
19.1
12.7
28.6
19.1
12.7
28.6
19.1
20
25
40
32
40
34
16
18
R-410A
12.7
12.7
28.6
28.6
22.2
22.2
1000
3N~ / 50 / 380-415
32
40
22
10
12
24
8
16
26
12
14
28
12
16
30
12
18
32
16
16
36
16
20
22
V
61.5
61.5
69.0
-
24
V
67.4
67.4
75.0
-
26
V
73.5
73.5
82.5
-
28
V
78.5
78.5
87.5
-
30
V
83.5
83.5
93.5
-
32
V
90
90
100
-
34
36
V
V
95.0 101.0
95.0 101.0
106.0 113.0
-
275
550
715
15.9
28.6
28.6
300
600
780
15.9
34.9
28.6
325
650
845
19.1
34.9
28.6
350
700
910
19.1
34.9
28.6
375
750
975
19.1
34.9
28.6
400
800
1040
19.1
34.9
28.6
425
850
1105
19.1
34.9
28.6
450
900
1170
19.1
41.3
28.6
63
63
63
63
80
80
80
80
12.7
28.6
22.2
15.9
28.6
22.2
15.9
28.6
22.2
15.9
28.6
28.6
15.9
28.6
28.6
40
40
50
50
50
38
40
42
44
46
8
10
10
12
14
10
12
16
16
16
20
18
16
16
16
38
40
42
44
46
V
V
V
V
V
106.4 111.5 118.0 123.5 130.0
106.4 111.5 118.0 123.5 130.0
119.5 125.0 131.5 137.5 145.0
64 (1)
475
500
525
550
575
950 1000 1050 1100 1150
1235 1300 1365 1430 1495
19.1 19.1 19.1 19.1 19.1
41.3 41.3 41.3 41.3 41.3
34.9 34.9 34.9 34.9 34.9
1000
100
100
100
100
100
REMQ5T
1685x930x765
198
162
78
58
-20(2) / -5~43
-20~15.5
8~43
-20~20 / 24 (2)
-20~43
mm
kg
m3/min
dBA
dBA
°CDB
°CWB
R-410A
3N~ / 50 / 380-415
20
Hz/V
A
1 Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, hydrobox, etc.) and the connection ratio restriction for the system (50%<=CR<=130%) 2 Field setting
48
48
16
16
16
48
V
135
135
150
-
50
52
16
16
16
18
18
18
50
52
V
V
140.0 145.0
140.0 145.0
156.0 162.0
-
54
18
18
18
54
V
150
150
168
-
600
1200
1560
19.1
41.3
34.9
625
1250
1625
19.1
41.3
34.9
650
1300
1690
19.1
41.3
34.9
675
1350
1755
19.1
41.3
34.9
125
125
125
125
Individual branch selector
for VRV IV heat recovery - BS1Q-A
BS1Q10A
Cooling
Nom.
Heating
Nom.
Maximum number of connectable indoor units
Maximum capacity index of connectable indoor units
Casing
Material
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Piping
Outdoor unit
Liquid Type/OD
connections
Gas
Type/OD
Discharge gas Type/OD
Indoor unit
Liquid Type/OD
Gas
Type/OD
Sound absorbing thermal insulation
Power supply
Phase/Frequency/Voltage
Total circuit
Maximum fuse amps (MFA)
Connectable outdoor units
BS1Q16A
0.005
0.005
kW
kW
6
15 < x ≤ 100
BS1Q25A
8
100<x≤160
Galvanised steel plate
mm
kg
mm
mm
mm
mm
mm
160<x≤250
Galvanised steel
207x388x326
12
15
Brazing connection/9.5
Brazing connection/15.9
Brazing connection/12.7
Brazing connection/9.5
Brazing connection/15.9
Foamed polyurethane, frame resisting needle felt
1~/50/220-240
15
REYQ-T
Hz/V
A
Brazing connection/22.2
Brazing connection/19.1
Brazing connection/22.2
Multi branch selector
for VRV IV heat recovery - BS-Q14A
Cooling
Nom.
kW
Power input
Heating
Nom.
kW
Maximum number of connectable indoor units
Maximum number of connectable indoor units per branch
Number of branches
Maximum capacity index of connectable indoor units
Maximum capacity index of connectable indoor units per branch
Casing
Material
Dimensions
Unit
HeightxWidthxDepth mm
Weight
Unit
kg
Liquid Type/OD mm
Outdoor unit
Gas
Type/OD mm
Piping connections
Discharge gas Type/OD mm
Liquid Type/OD mm
Indoor unit
Gas
Type/OD mm
Drain pipe size
Power supply
Phase/Frequency/Voltage
Hz/V
Total circuit
Maximum fuse amps (MFA)
A
Connectable outdoor units
BS4Q14A
0.043
0.043
20
BS6Q14A
0.064
0.064
30
BS8Q14A
0.086
0.086
40
4
400 or less
6
600 or less
8
298x370x430
17
9.5
22.2
19.1
298x580x430
24
12.7
28.6
19.1
BS10Q14A
0.107
0.107
50
BS12Q14A
0.129
0.129
60
BS16Q14A
0.172
0.172
64
5
49
10
12
750 or less
140 or less
Galvanised steel plate
298x580x430
298x820x430
298x820x430
26
35
38
12.7
15.9
15.9
28.6
28.6
28.6
19.1
28.6
28.6
9.5
15.9
ID 20 / OD 26 (VP20)
1~/220-240/50
15
REYQ-T
16
298x1060x430
50
19.1
34.9
28.6
VRV IV HEAT
RECOVERY
Power input
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Residential type indoor units
(such as Daikin Emura)
Hot water
Low temperature hydrobox
Control systems
VRV IV
heat pump
VRV IV standards:
99 7 segment indicator
99Variable refrigerant temperature
Customize your VRV for best seasonal efficiency & comfort
99Continuous heating
99 Automatic refrigerant charge
99 Refrigerant containment check
99 Night quiet mode
99 Manual low noise function
99 Full inverter compressors
The new standard in heating comfort
99 Gas cooled PCB
99VRV configurator
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
AHU connection kit
99 4 side heat exchanger
Software for simplified commissioning,
configuration and customisation
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 DC fan motor
99 E-pass heat exchanger
99 I demand function
99 Manual demand function
For detailed explanation of these functions refer to VRV IV technologies tab
50
VRV IV HEAT
PUMP
Wide range of indoor units
Combine VRV indoor units with stylish indoor units (Daikin Emura, Nexura, …)
FXSQ-P
VRV indoor unit
FXFQ-A
VRV indoor unit
FVXG-K
Nexura
BPMKS967B2
FTXG-LW
Daikin Emura
Connectable indoor units
15 CLASS
20 CLASS
25 CLASS
35 CLASS
FTXG20LW
FTXG20LS
FTXG25LW
FTXG25LS
FTXG35LW
FTXG35LS
FTXS20K
FTXS25K
FTXS35K
CTXS35K
Nexura – Floor standing unit
FVXG25K
FVXG35K
FVXG50K
Floor standing unit
FVXS25F
FVXS35F
FVXS50F
Flexi type unit
FLXS25B
FLXS35B9
FLXS50B
Daikin Emura – Wall mounted unit
Wall mounted unit
CTXS15K
BPMKS box needed to connect RA indoors to VRV IV (RYYQ-T and RXYQ-T)
51
42 CLASS
50 CLASS
60 CLASS
71 CLASS
FTXS60G
FTXS71G
FTXG50LW
FTXG50LS
FTXS42K
FTXS50K
FLXS60B
VRV IV proven in practice:
40% more efficient
A field trial at a German fashion chain store demonstrated how the innovative features of VRV IV
have improved energy efficiency dramatically over previous models.
Results: up to 60% less energy consumed
The results of the trial showed that the new VRV IV system consumed much less energy, particularly when cooling, compared with the VRV III
system – in some cases up to 60% less. When heating, savings were an average of 20%.
The Unterhachingtrial demonstrates how VRV IV heat pump technology uses a renewable energy source – air - to provide a complete and
environmentally sustainable solution for heating, cooling, and ventilation in commercial environments. The trial also shows that businesses can
only identify and control energy wastage through careful and intelligent monitoring of climate control systems, a service which Daikin can offer.
220
Energy use VRV III in 2012 in kWh
Energy use VRV IV in 2013 in kWh
Energy saving in %
Trendline energy use VRV III
Trendline energy use VRV IV
Trendline energy saving
210
200
190
180
170
160
150
140
130
120
110
70
100
60
90
50
80
70
40
60
30
50
Average daily
consumption
during working
hours in kWh
40
20
30
10
20
0%
10
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
52
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Energy saving
in %
VRV IV HEAT
PUMP
Free combination of outdoor units
Freely combine outdoor units to optimise for small footprint, continuous heating, highest efficiency or any other combination
Flexible piping design
Total piping length
1000m
Longest length actual (Equivalent)
165m (190m)
Longest length after first branch
90m1
Level difference between indoor and outdoor units
90m1
Level difference between indoor units
30m
53
90m maximum
30m Level difference between indoor units
40m (90m1) Level difference between indoor
and outdoor units
165m Actual piping length
1 Contact your local dealer for more information and restrictions
2 in case outdoor unit is located below indoor units
Specifications
VRV IV heat pump with continuous heating - RYYQ8-54T
VRV IV heat pump without continuous heating - RXYQ8-54T
OUTDOOR UNIT
Capacity range
Cooling capacity
Heating capacity
Nom.
Nom. / Max.
Cooling
Nom.
Power input - 50Hz
Heating
Nom. / Max.
EER
ESEER
COP
Nom. / Max.
Maximum number of connectable indoor units
Min.
Indoor index
Nom.
connection
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit RYYQ/RXYQ/RXYQQ
Fan
Air flow rate
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Cooling
Min.~Max.
Operation range
Heating
Min.~Max.
Refrigerant
Type
Liquid
OD
Piping connections Gas
OD
Total piping length System Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
HP
kW
kW
kW
kW
Capacity range
Cooling capacity
Heating capacity
mm
kg
m³/min
dBA
dBA
°CDB
°CWB
mm
mm
m
Hz/V
A
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom. / Max.
Cooling
Nom.
Power input - 50Hz
Heating
Nom. / Max.
EER
ESEER
COP
Nom. / Max.
Maximum number of connectable indoor units
Min.
Indoor index
Nom.
connection
Max.
Liquid
OD
Piping connections Gas
OD
Total piping length System Actual
Current - 50Hz
Maximum fuse amps (MFA)
10
12
14
16
18
20
8
22.4
22.4 / 25.0
5.21
4.75 / 5.5
4.30
6.37 (2) / 7.53 (3)
4.72 / 4.54
10
28.0
28.0 / 31.5
7.29
6.29 / 7.38
3.84
5.67 (2) / 7.20 (3)
4.45 / 4.27
12
33.5
33.5 / 37.5
8.98
7.77 / 9.1
3.73
5.50 (2) / 6.96 (3)
4.31 / 4.12
14
40.0
40.0 /45.0
11.0
9.52 / 11.2
3.64
5.31 (2) / 6.83 (3)
4.20 / 4.02
64 (1)
175
350
455
16
45.0
45.0 / 50.0
13.0
11.1 / 12.8
3.46
5.05 (2) / 6.50 (3)
4.05 / 3.91
18
50.0
50.0 / 56.0
14.7
12.4 / 14.4
3.40
4.97 (2) / 6.38 (3)
4.03 / 3.89
20
56.0
56.0 / 63.0
18.5
14.5 / 17.0
3.03
4.42 (2) / 5.67 (3)
3.86 / 3.71
100
200
260
OUTDOOR SYSTEM
System
8
125
150
250
300
325
390
1,685x930x765
268 / 194 / 194
175
185
79
261 / 187 / 187
162
78
58
200
225
400
450
520
585
1,685x1,240x765
364 / 305 / 305
223
398 / 314 / 314
260
81
61
250
500
650
251
261
88
66
86
64
65
-5~43
-20~15.5
R-410A
12.7
9.52
19.1
15.9
22.2
20
28.6
1,000
3N~ / 50 / 380-415
32
25
22
24
10
12
8
16
26
28
14
12
16
40
30
18
50
32
34
36
16
16
18
20
32
90.0
90.0 / 100.0
26.0
22.2 / 25.6
3.46
5.05 (2) / 6.50 (3)
4.05 / 3.91
34
95.0
95.0 / 106.0
27.7
23.5 / 27.2
3.43
5.01 (2) / 6.44 (3)
4.04 / 3.90
36
101.0
101.0 / 113.0
31.5
25.6 / 29.8
3.21
4.68 (2) / 6.02 (3)
3.95 / 3.79
400
800
1,040
425
850
1,105
450
900
1,170
HP
kW
kW
kW
kW
mm
mm
m
A
22
61.5
61.5 / 69.0
16.3
14.06 / 16.5
3.77
5.58 (2) / 7.07 (3)
4.37 / 4.18
24
67.4
67.4 / 75.0
18.2
15.85 / 18.3
3.70
5.42 (2) / 6.81 (3)
4.25 / 4.10
26
73.5
73.5 / 82.5
20.0
17.29 / 20.3
3.68
5.39 (2) / 6.89 (3)
4.25 / 4.06
275
550
715
300
600
780
325
650
845
28
30
78.5
83.5
78.5 / 87.5
83.5 / 93.5
22.0
23.7
18.87 / 21.9
20.17 / 23.5
3.57
3.52
5.23 (2) / 6.69 (3)
5.17 (2) / 6.60 (3)
4.16 / 4.00
4.14 / 3.98
64 (1)
350
375
700
750
910
975
15.9
19.1
28.6
34.9
1,000
63
54
41.3
80
VRV IV HEAT
PUMP
OUTDOOR SYSTEM
System
38
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Capacity range
Cooling capacity
Heating capacity
Nom.
Nom. / Max.
Cooling
Nom.
Power input - 50Hz
Heating
Nom. / Max.
EER
ESEER
COP
Nom. / Max.
Maximum number of connectable indoor units
Min.
Indoor index
Nom.
connection
Max.
Liquid
OD
Piping connections Gas
OD
Total piping length System Actual
Current - 50Hz
Maximum fuse amps (MFA)
HP
kW
kW
kW
kW
mm
mm
m
A
OUTDOOR UNIT MODULE FOR RYYQ-T COMBINATIONS
Dimensions
Weight
Fan
Sound power level
Sound pressure level
Operation range
Refrigerant
Power supply
Current - 50Hz
Unit
HeightxWidthxDepth
Unit
Air flow rate
Cooling Nom.
Cooling
Nom.
Cooling
Nom.
Cooling
Min.~Max.
Heating
Min.~Max.
Type
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
40
42
44
46
48
50
52
54
8
10
10
12
14
16
16
16
18
10
12
16
18
20
18
16
18
38
40
42
44
46
48
50
52
54
106.0
112.0
118.0
124.0
130.0
135.0
140.0
145.0
150.0
106.0 / 120.0 112.0 / 125.0 118.0 / 132.0 124.0 / 138.0 130.0 / 145.0 135.0 / 150.0 140.0 / 156.0 145.0 /162.0 150.0 / 168.0
31.0
33.3
35.0
37.0
39.0
40.7
42.4
44.1
25.54 / 29.9 26.46 / 30.9 28.49 / 33.0 29.97 / 34.7 31.72 / 36.8 33.30 / 38.4
34.6 / 40.0
35.9 / 41.6
37.2 / 43.2
3.42
3.61
3.54
3.51
3.46
3.44
3.42
3.40
5.03 (2) / 6.36 (3) 5.29 (2) / 6.74 (3) 5.19 (2) / 6.65 (3) 5.17 (2) / 6.62 (3) 5.13 (2) / 6.60 (3) 5.05 (2) / 6.50 (3) 5.02 (2) / 6.46 (3) 4.99 (2) / 6.42 (3) 4.97 (2) / 6.38 (3)
4.15 / 4.01
4.23 / 4.05
4.14 / 4.00
4.14 / 3.98
4.10 / 3.94
4.05 / 3.91
4.05 / 3.90
4.04 / 3.89
4.03 / 3.89
64 (1)
475
500
525
550
575
600
625
650
675
950
1,000
1,050
1,100
1,150
1,200
1,250
1,300
1,350
1,235
1,300
1,365
1,430
1,495
1,560
1,625
1,690
1,755
19.1
41.3
1,000
100
125
RYMQ8T
mm
kg
m³/min
dBA
dBA
°CDB
°CWB
Hz/V
A
RYMQ10T
1,685x930x765
195
175
79
188
162
78
58
RYMQ12T
RYMQ14T
185
223
RYMQ16T
RYMQ18T
1,685x1,240x765
309
81
61
RYMQ20T
319
260
251
86
64
65
261
88
66
-5~43
-20~15.5
20
3N~ / 50 / 380-415
32
25
40
50
(1) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (2) The STANDARD ESEER value corresponds with normal VRV4
Heat Pump operation, not taking into account advanced energy saving operation functionality (3) The AUTOMATIC SEER value corresponds with normal VRV4 Heat Pump operation, taking into account advanced energy saving operation functionality ( variable
refrigerant temperature control operation) (4) RYYQ-T multi combinations use RYMQ-T modules, RXYQ-T multi combinations use RXYQ-T modules.
55
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Residential type indoor units
(such as Daikin Emura, ...)
Ventilation
Heat Reclaim ventilation (VAM/VKM)
AHU connection kit
Control systems
VRV III-S
heat pump
Optimised design
for small capacities
99 Automatic refrigerant charge
99 Refrigerant containment check
99 Night quiet mode
99 Manual low noise function
99 Full inverter compressors
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 DC fan motor
99 E-pass heat exchanger
99 I demand function
99 Manual demand function
56
1,685 mm
Space saving design
1,345 mm
The VRVIII-S is slimmer and more compact, resulting in significant
savings in installation space.
Volume Approx. 70%
Reduction
Footprint Approx. 60%
Reduction
765mm
320mm
900mm
930mm
Wide range of indoor units
Connect VRV units…
VRV III-S HEAT
PUMP
FXFQ-A
FXZQ-A
FXSQ-P
FXAQ-P
… or stylish indoor units
FCQG-F
BPMKS967B2
FTXG-JA - Daikin Emura
FBQ-C
FVXG-K
Nexura
BPMKS967B2
Connectable indoor units
15 CLASS
20 CLASS
Round flow cassette
Fully flat cassette
Small concealed ceiling unit
Slim concealed ceiling unit
Concealed ceiling unit with inverter driven fan
new
FFQ25C
35 CLASS
50 CLASS
60 CLASS
FCQG35F
42 CLASS
FCQG50F
FCQG60F
FFQ35C
FFQ50C
FFQ60C
71 CLASS
FDBQ25B
FDXS25F
Daikin Emura – Wall mounted unit
Wall mounted unit
25 CLASS
CTXS15K
Ceiling suspended unit
Nexura – Floor standing unit
Floor standing unit
Flexi type unit
FDXS35F
FDXS50F9
FDXS60F
FBQ35C8
FBQ50C8
FBQ60C8
FTXG50LW
FTXG50LS
FTXG20LW
FTXG20LS
FTXG25LW
FTXG25LS
FTXG35LW
FTXG35LS
FTXS20K
FTXS25K
FTXS35K
CTXS35K
FTXS50K
FTXS60G
FHQ35C
FHQ50C
FHQ60C
FVXG25K
FVXG35K
FVXG50K
FVXS25F
FVXS35F
FVXS50F
FLXS25B
FLXS35B9
FLXS50B
* VRV indoor units and stylish indoor units cannot be combined.
57
FTXS42K
FLXS60B
FTXS71G
High COP values
A major feature of VRVIII-S is its exceptional energy efficiency.
The system achieves high COPs during both cooling and heating
operation by the use of refined components and functions.
Cooling
Heating
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB,
outdoor temperature: 35°C, equivalent refrigerant piping: 5m, level difference: 0m.
2
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor
temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m
1
3.99 1
4.55 2
012 3 45
-
Minimum piping length between BP and indoor unit
-
2m
Maximum piping length between BP and indoor unit
-
15m
40m
40m
Level difference between indoor and outdoor units
Level difference between indoor units
5m
50m (40m1)
30m
15m
15m
Outdoor unit in lowest position
58
40m maximum
250m
Minimum length between outdoor unit and first branch
Longest length after first branch
1
300m
150m (175m)
15m Level difference between indoor units
Longest length actual (Equivalent)
Stylish indoors
connected
150m Actual piping length
Total piping length
VRV indoors
connected
50m Level difference between indoor
and outdoor units
Flexible piping design
Advanced technologies
1 Super aero grille
The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.
2 Smooth air inlet bell mouth
Aero spiral fan blade tips
and aero spiral fan
These features assist in significantly reducing noise. Guides are
added to the bell mouth intake to reduce turbulence in the air
flow generated by fan suction. The aero spiral fan features fan
blades with bent blade edges, further reducing turbulence.
Conventional
New
Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.
Current
Evaporativecapacity
Prevents accumulation of liquid refrigerant in the condenser.
This results in more efficient use of the condenser surface
under all conditions and leads in turn to better energy
efficiency. Increased evaporative capacity stems from
the newly developed refrigeration circuit, the SCe-bridge
circuit, which adds super cooling prior to the expansion cycle.
By adopting this circuit, the COPs in both coolingand heating
have been drastically improved.
Evaporative capacity
can be raised by taking
super cooling just
before the electronic
expansion valve
By the SCe- bridge
circuit, cooling and
heating attain the
improvement in COP
Evaporative-capacity has been improved by
adopting the SCe-Bridge Circuit circuit.
SCe-Bridge Circuit
3
Specifications
2
1
VRVIII-S Heat pump - single phase (P8V1), three phase (P8Y1)
OUTDOOR UNIT
Capacity range
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan
Air flow rate
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure
Cooling
Nom.
level
Heating
Nom.
Operation range Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type
Piping
Liquid
OD
connections
Gas
OD
Total piping length System Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
HP
kW
kW
kW
kW
RXYSQ4P8V1
4
12.6
14.2
3.24
3.12
3.89
4.55
8 (1) / 8 (2)
50
RXYSQ5P8V1
5
14.0
16.0
3.51
3.86
3.99
4.15
10 (1) / 9 (2)
62.5
RXYSQ6P8V1
6
15.5
18.0
4.53
4.57
3.42
3.94
12 (1) / 9 (2)
70
130
162.5
182
RXYSQ4P8Y1
4
12.6
14.2
3.33
3.21
3.78
4.42
8 (1) / 8 (2)
50
RXYSQ5P8Y1
5
14.0
16.0
3.61
3.97
3.88
4.03
10 (1) / 9 (2)
62.5
RXYSQ6P8Y1
6
15.5
18.0
4.66
4.70
3.33
3.83
12 (1) / 9 (2)
70
130
162.5
182
66
50
52
67
51
53
69
53
55
mm
kg
m³/min
dBA
dBA
dBA
°CDB
°CWB
mm
mm
m
Hz/V
A
1,345x900x320
120
106
66
50
52
67
51
53
69
53
55
-5~46
-20~15.5
R-410A
9.52
15.9 (1) / 19.1 (2)
300 (1) / 115 (2)
300 (1) / 135 (2)
1N~/50/220-240
32.0
(1) In case VRV indoor units are connected (2) In case RA indoors are connected
59
19.1
300 (1) / 145 (2)
15.9 (1) / 19.1 (2)
300 (1) / 115 (2)
300 (1) / 135 (2)
3N~/50/380-415
16.0
19.1
300 (1) / 145 (2)
VRV III-S HEAT
PUMP
3 e-Bridge circuit
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
AHU connection kit
Control systems
VRV heat pump
optimised for heating
VRVIII-C
99 Automatic refrigerant charge
99 Refrigerant containment check
99 Night quiet mode
99 Manual low noise function
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 DC fan motor
99 E-pass heat exchanger
99 I demand function
99 Manual demand function
60
High COP at low ambients
The use of two stage compression technology results in improved
energy saving performance at low ambients, with a COP of more
than 3.0 at -10°C outdoor ambient for the entire range.
COP for a 10HP unit
4.00
ump
at p
he
dard
2.00
Stan
VRV III-C HEAT
PUMP
COP
3.00
1.00
0.00
-25
-20
-15
-10
-5
Outdoor temp. (WB°)
0
5
10
Wide heating operation range
VRVIII-C has a standard operation range down to -25 °CWB outdoor ambient in heating and can also provide cooling down to - 5 °CDB
outdoor ambient.
Heating mode
VRVIII-C
-25°CWB
Standard VRV
-20°CWB
Cooling mode
-5°C
15.5°C
43°CDB
Outdoor Temp.
Outdoor Temp.
Stable heating capacity
(kW) 35
30
heating capacity
VRVIII-C has a stable heating capacity, even in low ambients, making
it suitable for single source heating. The heating capacity is 130% in
comparison with the standard VRV heating capacity under similar
conditions
25
20
standard heat pump
15
10
5
0
61
-25
-20
-15
-10
-5
0
Outdoor temp. (°CWB)
Heating capacity 10HP outdoor unit
5
10
High heat up speed
Heat up time is dramatically reduced, particularly under low ambient conditions. The required time for the indoor unit heat exchanger
discharge temperature to reach 40°C has been reduced by 50%.
°C
Start heating operation
60
50
30
30
25
20
10
20
Standard heat pump
0
-20
-5
0
5 6
10
Elapsed time (min.)
Indoor heat exchanger temperature VRVIII-C
Indoor heat exchanger temperature standard heat pump
50% reduction
-10
Indoor temperature °C
Discharge temperature (°C)
40
Indoorpositie
temperatureblauwe
VRVIII-C
lijnen:
15
1415
20
X +10
Indoor temperature standard heat pump
* Field test data in Japan with 14 HP unit (Akita City Jan 2006)
Short defrost time
The time required for defrost is reduced to 4 minutes – less than half that of the standard VRVIII system (10 minutes), leading to a more stable
interior indoor temperature and considerably improved comfort levels.
* Field test data in Japan with 10 HP unit (Akita City Jan 2006)
500m
165m (190m)
Longest length between
outdoor unit and function unit
10m
Longest length after first branch
40m (90m1)
Level difference between
indoor and outdoor units
50m (40m²)
Level difference between indoor units
30m
1 Contact your local dealer for more information and restrictions
2 In case outdoor unit is located below indoor units
62
90m maximum
Longest length actual (Equivalent)
165m Actual piping length
Total piping length
50m Level difference between indoor
and outdoor units
15m Level difference between
indoor units
Flexible piping design
Two stage compression
Heating
capacity
Two stage compression technology enables the system to create
higher pressures resulting in a higher heating capacity under low
ambient conditions. The second inverter compressor (located in
the function unit) is specially designed to provide higher pressures.
High
After heat is exchanged in the indoor unit, gas and liquid are
separated at the gas-liquid separator. This enables the refrigerant
in gas condition to be recovered and transmitted direct to the high
pressure compressor.
Liquid injection
Gas-liquid
separator
Middle
Pressure
Gas injection
Low
Input power
Evaporator capacity
Enthalpy
VRV III-C HEAT
PUMP
Specifications
VRV Heat pump optimised for heating
RTSYQ-PA
OUTDOOR SYSTEM
System
Outdoor unit module 1
Outdoor unit module 2
Function unit
Capacity range
Cooling capacity
Heating capacity
Nom.
Nom.
Cooling
Nom.
Power input - 50Hz
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Min.
Indoor index
Nom.
connection
Max.
Sound pressure level Cooling
Max./Nom.
Liquid
OD
Gas
OD
Piping
connections
Oil equalizing
OD
Total piping length System Actual
Current - 50Hz
Maximum fuse amps (MFA)
RTSYQ10PA
RTSQ10PAY1
RTSYQ14PA
RTSQ14PAY1
-
10
28.0 (1)
31.5 (2) / 28.0 (3)
7.90 (1)
7.78 (2) / 8.18 (3)
3.54 (1)
4.05 (2) / 3.42 (3)
21
125
250
325
62/60
9.52
22.2
14
40.0 (1)
45.0 (2) / 40.0 (3)
12.6 (1)
11.4 (2) / 12.8 (3)
3.17 (1)
3.95 (2) / 3.13 (3)
30
175
350
455
63/61
RTSYQ16PA
RTSQ16PAY1
RTSYQ20PA
RTSQ8PAY1
RTSQ12PAY1
16
45.0 (1)
50.0 (2) / 45.0 (3)
14.9 (1)
13.0 (2) / 15.0 (3)
3.02 (1)
3.85 (2) / 3.00 (3)
34
200
400
520
20
56.0 (1)
63.0 (2) / 55.9 (3)
15.4 (1)
15.4 (2) / 18.7 (3)
3.64 (1)
4.09 (2) / 2.99 (3)
43
250
500
650
BTSQ20PY1
HP
kW
kW
kW
kW
dBA
mm
mm
mm
m
A
65/63
12.7
15.9
28.6
-
19.1
500
25
35
40
50
(1) Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; (2) Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB,6°CWB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; (3) Heating: Indoor temp. 20°CDB; outdoor temp. -10°CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m
OUTDOOR UNIT MODULE
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan
Air flow rate
Cooling Nom.
Sound power level Cooling
Nom.
Operation range Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
mm
kg
m³/min
dBA
°CDB
°CWB
Hz/V
A
BTSQ20P
1,570x460x765
110
-
RTSQ8PA
RTSQ10PA
1,680x930x765
205
RTSQ12PA
257
185
200
RTSQ14PA
RTSQ16PA
1,680x1,240x765
338
344
233
239
-5~43
-25~15.5
R-410A
3~/50/380-415
20
25
63
35
40
22
Indoor units
VRV type indoor units
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
Control systems
VRV Classic
heat pump RXYCQ-A
99 Manual low noise function
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 DC fan motor
99 E-pass heat exchanger
99 Manual demand function
64
Benefits
•
•
•
•
•
For projects with standard cooling & heating requirements
Fits any building as also indoor installation is possible as a result of high external static pressure of up to 78.4 Pa. Indoor installation leads to less
piping length, lower installation costs, increased efficiency and better visual aesthetics
The ability to control each conditioned zone individually keeps VRV system running costs to an absolute minimum
Spread your installation cost by phased installation
Connectable to all standard VRV indoor units, controls and ventilation
Flexible piping design
300m
Longest length actual (Equivalent)
VRV CLASSIC
Total piping length
135m (155m)
40m (90m1)
Longest length after first branch
Level difference between indoor and outdoor units
30m
Level difference between indoor units
15m
1 Contact your local dealer for more information and restrictions
Specifications
VRV Classic - RXYCQ-A
OUTDOOR UNIT
Capacity range
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan
Air flow rate
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type
Piping
Liquid
OD
connections
Gas
OD
Total piping length System Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
HP
kW
kW
kW
kW
mm
kg
m³/min
dBA
dBA
°CDB
°CWB
mm
mm
m
Hz/V
A
RXYCQ8A
8
20.0
22.4
6.60
5.80
3.03
3.86
16
100
200
240
1,680x635x765
159
95
78
58
15.9
RXYCQ10A
10
25.0
28.0
6.74
7.00
3.71
4.00
20
125
250
300
187
171
59
9.52
19.1
RXYCQ12A
RXYCQ14A
12
14
30.0
35.0
33.6
37.5
8.77
11.4
8.62
9.74
3.42
3.07
3.90
3.85
24
28
150
175
300
350
360
420
1,680x930x765
240
185
196
81
61
-5.0~43.0
-20.0~15.5
R-410A
RXYCQ16A
16
40.0
44.8
12.9
11.8
3.10
3.80
32
200
400
480
64
RXYCQ18A
18
45.0
50.4
15.0
13.8
3.00
3.65
36
225
450
540
1,680x1,240x765
316
233
86
65
12.7
22.2
16
25
65
324
239
88
66
15.9
28.6
300
3N~/50/380-415
(1) Connection ratio is 50~120%. If only FXFQ20,25 units are connected, maximum connection ratio is 100%
RXYCQ20A
20
50.0
56.0
17.8
16.0
2.81
3.50
40
250
500
600
40
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
AHU connection kit
VRV III
Control systems
VRV IV
Replacement VRV
RQYQ-P / RXYQQ-T (Heat pump)
RQCEQ-P (Heat recovery)
Heat pump
Heat pump & Heat recovery
99Variable refrigerant temperature
99
99
99
99
99
99
99
99
99
99
Customize your VRV for best seasonal efficiency & comfort
99VRV configurator
Software for simplified commissioning,
configuration and customisation
99
99
99
99
99
99
99
99
99
99
99
99
99
7 segment indicator
Automatic refrigerant charge
Night quiet mode
Manual low noise function
Full inverter compressors
Gas cooled PCB
4 side heat exchanger
Reluctance brushless DC compressor
Sine wave DC inverter
DC fan motor
E-pass heat exchanger
I demand function
Manual demand function
Automatic refrigerant charge
Night quiet mode
Manual low noise function
Full inverter compressors
Reluctance brushless DC compressor
Sine wave DC inverter
DC fan motor
E-pass heat exchanger
I demand function
Manual demand function
For more information on these features refer to the VRV IV technologies tab
66
The Daikin solution to R-22 phase-out
Replace your R-22 / R-407C outdoor unit with R-410A technology, but keep your refrigerant piping and in some cases your indoor units1.
1.
2.
3.
4.
Replace outdoor unit
Replace BS-boxes (in case of H/R)
Replace indoor units (check with your local dealer if needed)
The system will automatically clean the piping & charge the correct amount of R-410A refrigerant
replace
KEEP
replace
* When R-22 indoors are K-series or later, it is possible to keep the indoor units.
Plan your system replacement now
2014
01/01/2015
STOP
REPLACEMENT
VRV
…
From 01/01/2015 there is a ban on the use of all R-22 for service
& maintenance. Daikin advises to replace your system now to
prevent unplanned downtime.
Increased efficiency
Upgrading an old R-22 system to a Replacement VRV system will result in increased system efficiency. Efficiency gains of more than 70% in
cooling can be realized, by virtue of technological developments in current heat pump technology such as variable refrigerant temperature and
the more efficient R-410A refrigerant. Increased energy efficiency equals lower energy consumption, subsequent lower energy costs and lower
CO2 emissions.
81%
less consumption
in cooling mode
48%
Energy use of a 10HP system in cooling
less consumption
in heating mode
Energy consumption
Energy consumption
Energy use of a 10HP system in heating
R-22 R-407C R-410A R-22 R-407CR-410A
67
Environmental awareness R-410A not only has a zero ozone depletion potential, it is also proven to be more energy efficient than R-22.
Fast installation
It is not necessary to remove the existing piping and even the indoor units can remain (depending on type of indoor unit).
The outdoor unit automatically charges the refrigerant and cleans the refrigerant piping. This unique Daikin feature makes the installation time
even shorter.
No restrictions on system history
As a result of the combined automatic charging and refrigerant pipe cleaning function, it is possible to ensure a clean piping network, even when
a compressor breakdown has previously occurred.
Limited and planned-downtime
As the refrigerant piping can be maintained the installation is less intrusive and less time consuming than for a completely new system. Moreover,
downtime can be carefully planned: whereas if a problem occurs when not enough reclaimed R-22 is available, a long and unplanned downtime
can be the result.
Limited and phased investment cost
It is possible to spread the various stages of replacement over a certain period of time because the indoor units can remain in most cases. The
air conditioning replacement therefore, can be incorporated in the general refurbishment schedule of the building and the investment cost can
be spread. A further reduction in installation cost can be achieved by maintaining the old refrigerant copper pipe work.
68
Increase capacity Cooling loads often increase subsequent to the initial installation of the air conditioning system. The Replacement VRV(VRVIII-Q) enables system
capacity to be increased without changing the refrigerant piping (depending on system characteristics).
Example: replace a 10HP VRV with a 16HP Replacement VRV unit
10 HP
16 HP
1.
1. Keep main piping
2. Add indoor units
2.
Reduced pressure
As R-22 VRV systems used to work on a lower pressure than R-410A systems / thus the copper refrigerant piping was also designed for these
lower pressures. Therefore the Replacement VRV must operate at lower pressures than the standard VRV series. However thanks to the sub cool
circuit a high efficiency level can be kept even with the lower pressures.
Pressure
A
replace*
}
3.3 MPa
}
3.8 MPa
B
~
A
B
~
Decompression to 3.3MPa(s)
Extra sub cool circuit
Enthalpy
R-22 existing piping can be used
high COP
69
REPLACEMENT
VRV
Technologies
Specifications
RQYQ140P
RXYQQ-T
Replacement VRV heat pump (RQYQ-P / RXYQQ-T)
OUTDOOR UNIT
Capacity range
Cooling capacity
Heating capacity
Power input 50Hz
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
EER
ESEER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan
Air flow rate
Cooling Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type
Piping
Liquid
OD
connections
Gas
OD
Total piping length System Actual
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
OUTDOOR UNIT
System
Capacity range
Cooling capacity
Heating capacity
Power input 50Hz
Capacity range
Cooling capacity
Heating capacity
Power input 50Hz
RXYQQ22T
RXYQQ10T
RXYQQ12T
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
EER
ESEER
COP
Maximum number of connectable indoor units
Piping
Liquid
OD
connections
Gas
OD
Total piping length System Actual
Current - 50Hz
Maximum fuse amps (MFA)
OUTDOOR UNIT
System
RQYQ140P
RXYQQ8T
RXYQQ10T
RXYQQ12T
RXYQQ14T
RXYQQ16T
RXYQQ18T
RXYQQ20T
5
8
10
12
14
16
18
20
14.0
22.4
28.0
33.5
40.0
45.0
50.0
56.0
16.0
25.0
31.5
37.5
45.0
50.0
56.0
63.0
3.36
5.21
7.29
8.98
11.0
13.0
14.7
18.5
3.91
5.51
7.38
9.10
11.2
12.8
14.4
17.0
4.17
4.30
3.84
3.73
3.64
3.46
3.40
3.03
6.37 (2) / 7.53 (3) 5.67 (2) / 7.20 (3) 5.50 (2) / 6.96 (3) 5.31 (2) / 6.83 (3) 5.05 (2) / 6.50 (3) 4.97 (2) / 6.38 (3) 4.42 (2) / 5.67 (3)
4.09
4.54
4.27
4.12
4.02
3.91
3.89
3.71
10
64 (1)
62.5
100
125
150
175
200
225
250
125
200
250
300
350
400
450
500
162.5
260
325
390
455
520
585
650
mm
1,680x635x765
1,685x930x765
1,685x1,240x765
kg
175
187
194
305
314
m³/min
162
175
185
223
260
251
261
dBA
78
79
81
86
88
dBA
54
58
61
64
65
66
°CDB
-5~43
°CWB
-20~15.5
R-410A
mm
9.52
12.7
15.9
mm
15.9
19.1
22.2
28.6
m
300
Hz/V
3~/50/380-415
3N~/50/380-415
A
15
20
25
32
40
50
HP
kW
kW
kW
kW
Nom.
Nom.
EER
ESEER
COP
Maximum number of connectable indoor units
Piping
Liquid
OD
connections
Gas
OD
Total piping length System Actual
Current - 50Hz
Maximum fuse amps (MFA)
RXYQQ26T
RXYQQ14T
RXYQQ28T
RXYQQ12T
RXYQQ16T
RXYQQ30T
RXYQQ32T
RXYQQ18T
RXYQQ16T
RXYQQ34T
RXYQQ16T
RXYQQ18T
RXYQQ36T
RXYQQ20T
HP
kW
kW
kW
kW
mm
mm
m
A
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Nom.
Nom.
Cooling
Heating
RXYQQ24T
RXYQQ8T
RXYQQ16T
HP
kW
kW
kW
kW
22
24
26
28
30
32
34
36
61.5
67.4
73.5
78.5
83.5
90.0
95.0
101.0
69.0
75.0
82.5
87.5
93.5
100.0
106.0
113.0
16.3
18.2
20.0
22.0
23.7
26.0
27.7
31.5
16.5
18.3
20.3
21.9
23.5
25.6
27.2
29.8
3.77
3.70
3.68
3.57
3.52
3.46
3.43
3.21
5.58 (2) / 7.07 (3) 5.42 (2) / 6.81 (3) 5.39 (2) / 6.89 (3) 5.23 (2) / 6.69 (3) 5.17 (2) / 6.60 (3) 5.05 (2) / 6.50 (3) 5.01 (2) / 6.44 (3) 4.68 (2) / 6.02 (3)
4.18
4.10
4.06
4.00
3.98
3.91
3.90
3.79
64 (1)
15.9
19.1
28.6
34.9
41.3
300
63
80
RXYQQ38T
RXYQQ8T
RXYQQ10T
RXYQQ20T
38
106.0
120.0
RXYQQ40T
RXYQQ10T
RXYQQ12T
RXYQQ18T
40
112.0
125.0
31.0
29.9
3.42
5.03 (2) / 6.36 (3)
4.01
mm
mm
m
A
30.9
3.61
5.29 (2) / 6.74 (3)
4.05
64 (1)
19.1
41.3
300
100
RXYQQ42T
RXYQQ10T
RXYQQ16T
RXYQQ16T
42
118.0
132.0
33.3
33.0
3.54
5.19 (2) / 6.65 (3)
4.00
(1) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%) (2) The STANDARD ESEER value corresponds with normal
VRV4 Heat Pump operation, not taking into account advanced energy saving operation functionality (3) The AUTOMATIC SEER value corresponds with normal VRV4 Heat Pump operation, taking into account advanced energy saving operation functionality (
variable refrigerant temperature control operation)
70
RQCEQ-P
Replacement VRV heat recovery (RQCEQ-P)
OUTDOOR UNIT MODULE
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Sound pressure level Cooling
Nom.
Operation range Cooling
Min.~Max.
Heating
Min.~Max.
Refrigerant
Type
Power supply
Phase/Frequency/Voltage
HP
kW
kW
kW
kW
dBA
mm
mm
mm
m
m
m
A
RQCEQ280P RQCEQ360P RQCEQ460P RQCEQ500P RQCEQ540P RQCEQ636P RQCEQ712P RQCEQ744P RQCEQ816P RQCEQ848P
RQEQ140P RQEQ180P
RQEQ140P
RQEQ180P RQEQ212P
RQEQ140P
RQEQ180P RQEQ212P
RQEQ140P RQEQ180P RQEQ140P
RQEQ180P
RQEQ212P
RQEQ180P
RQEQ212P
RQEQ180P
RQEQ212P RQEQ180P
RQEQ212P
RQEQ212P
10
13
16
18
20
22
24
26
28
30
28.0
36.0
45.0
50.0
54.0
63.6
71.2
74.4
81.6
84.8
32.0
40.0
52.0
56.0
60.0
67.2
78.4
80.8
87.2
89.6
7.04
10.3
12.2
13.9
15.5
21.9
21.2
23.3
27.1
29.2
8.00
10.7
13.4
14.7
16.1
17.7
20.7
21.2
23.1
23.6
3.98
3.48
3.77
3.61
3.48
2.90
3.36
3.19
3.01
2.90
4.00
3.72
3.89
3.80
3.72
3.79
3.80
3.81
3.77
3.79
21
28
34
39
43
47
52
56
60
64
57
61
62
63
64
63
64
65
66
9.52
12.7
15.9
19.1
22.2
25.4
28.6
34.9
19.1
22.2
25.4
28.6
120
300
50 (outdoor unit in highest position)
30
40
50
60
70
80
90
RQEQ140P
mm
kg
dBA
°CDB
°CWB
RQEQ180P
1,680x635x765
175
54
58
-5~43
-20~15
R-410A
3~/50/380-415
Hz/V
Le Pigonnet
Hotel
Heating & Air Conditioning RQEQ212P
179
60
Refurbishment of the existing VRV system
of a luxury 5 star hotel to anticipate
R-22 phase out, keeping existing pipes
in order to preserve interior decoration.
8 VRVIII-Q RQYQ140P + 36 FXLQ25 + 3FVXS50+1FTXS
3MXS52+ 2 FVXS25, RXS50 + 1 FTXS50, RXS50 + 1 FVXS50, 3 MXS68 + 2 FVXS 25 + 1 FVXS50, RXS25 + FVXS25
71
REPLACEMENT
VRV
OUTDOOR SYSTEM
System
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Outdoor unit module 4
Capacity range
Cooling capacity Nom.
Heating capacity Nom.
Power input Cooling
Nom.
50Hz
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Sound pressure level Cooling
Nom.
Piping
Liquid
OD
connections
Gas
OD
Discharge gas
OD
Piping length
OU - IU Max.
Total piping length System Actual
Level difference OU - IU
Current - 50Hz
Maximum fuse amps (MFA)
Air curtain
Biddle Air curtain for VRV (CYV)
22
Indoor units
VRV type indoor units
Hot water
Low temperature hydrobox
Control systems
Ventilation
Heat Reclaim ventilation (VAM/VKM)
Fresh air indoor units (FXMQ-MF)
AHU connection kit
Water cooled
VRV IV W-series
VRV IV standards:
99 Full inverter compressors
99Variable refrigerant temperature
Customize your VRV for best seasonal efficiency & comfort
99 Reluctance brushless DC compressor
99 Sine wave DC inverter
99 Manual demand function
99 Geothermal operation
For more information on these features refer to the VRV IV technologies tab
72
Efficiency not influenced by outdoor conditions
The water cooled VRV unit operates at a superior efficiency, even in the most extreme outdoor temperatures thanks to geothermal operation.
Because the temperature of ground water, lakes and rivers, remains relatively constant the year round, our water-cooled system maintains its
superior efficiency, even in the most extreme outdoor temperatures, when the efficiency of air-cooled systems goes down.
Outside
temperature
WATER COOLED
VRV IV
Wind
Wide operation range
Standard water cooled outdoor units have a wide operation range between 10°C & 45°C inlet water temperature, both in heating and cooling.
In geothermal mode the operation range is extended even more, down to -10°C* in heating and 6°C in cooling mode.
* Ethylene glycol should be added to the water when the water inlet temperature is below 5°C
-10°C
45°
-6°C
Heating
45°
Cooling
73
High energy efficiencies results from 2-stage heat recovery
Stage 1: Heat recovery between indoor units in the same refrigerant circuit
Heat exhausted from indoor units in cooling mode is transferred to units in areas requiring heating, maximising energy efficiency and reducing
electricity costs.
Stage 2: Heat recovery between the outdoor units via the water loop - also available on heat pump units!
Second stage heat recovery is achieved within the water loop between the water cooled outdoor units.
stage 2
stage 2
stage 1
Heat recovery between indoor units
Heat recovery between outdoor units
(Heat recovery and heat pump)
Cooling tower (Closed type), boiler
All indoor units in
cooling mode
Heat rejected to loop
VRV-W
Indoor units mainly
cooling, partly heating
Heat rejected to loop
VRV-W
Full Heat Recovery
VRV-W
Indoor units
mainly heating,
partly cooling
Heat absorbed from loop
VRV-W
All indoor units
in heating mode
Heat absorbed from loop
* Above system configurations
are for illustration purposes only.
VRV-W
74
Space saving - Stacked configuration
The adoption of a new water heat exchanger and optimization of
the refrigerant control circuit has resulted in the industry’s most
compact and lightweight design. The unit weight of 149kg* and
height of 1,000 mm makes installation easy. Stacked configuration
is also possible, contributing further to space savings.
Ceiling height
3,200mm
or higher
* for 8HP unit
Floor level
100-300mm
Stacked configuration is possible.
Variable water flow control
The variable water flow control option reduces energy use by the circulation pump by reducing the water flow when possible and not using
a fixed water flow all the time.
Variable water
Flow Control Valve
Cooling tower (Closed type), boiler
WATER COOLED
VRV IV
Inverter
Pump
Standard water strainer
A standard water strainer reduces installation time. The new filter
also has less pressure drop at higher water flows.
40
35
Pressure drop (lkPa)
30
new filter
25
20
15
10
old filter
5
0
50 70 90 110 water flow (l/min)
75
130 150
For Gerard Schröder the choice for this system
‘As far as I’m concerned,
with the VRV Heat Recovery system,
Daikin has the Rolls Royce in
heat pump technology. If you want
to build a sustainable office building,
there really is no other alternative.’
was an easy one:
Park Phi, Enschede
The Netherlands
VRV-WIII geothermal system,
Daikin Altherma HT, Sky Air,
aircooled chiller with heat recovery,
iManager, iTouch Manager, ACNSS
BREEAM excellent office building
Flexible piping design
Flexible water piping
Water cooled VRV uses water as its heat source, so it is optimal for large buildings, including tall, multi-storey buildings, because the system can
tolerate water pressure of up to 1.96 MPa.
Furthermore, if the currently installed heat source’s water temperature is between 10°C and 45°C, it may be possible to use the existing water
pipe work and heat source. This alone makes it an ideal system solution for building refubishment projects.
Actual piping length between the VRV-W and indoor units: 120m (Equivalent piping length: 140m)
Water piping
Refrigerant piping
Level difference between indoor units: 15m
VRV-W
Level difference
between the VRV-W
and indoor units:
50m if the VRV-W is above
40m if the VRV-W is below
Total piping length
VRV-W
Longest length actual (Equivalent)
300m
120m (140m)
Longest length after first branch
40m (90m1)
Level difference between
indoor and outdoor units
50m (40m²)
Level difference between indoor units
Indoor installation
1 Contact your local dealer for more information and restrictions
2 In case outdoor unit is located below indoor units
Unlimited water piping length
76
15m
Specifications
Heat recovery
Heating & Cooling
Capacity
EER
PI
Heating capacity Capacity
EER
PI
Power input - 50Hz Cooling
Nom.
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Indoor index
Min.
connection
Nom.
Max.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Sound power level Cooling
Nom.
Sound pressure level Cooling
Nom.
Operation range Inlet water
Cooling Min.~Max.
temperature
Heating Min.~Max.
Refrigerant
Type
Piping
Liquid
OD
connections
Gas
OD
Discharge gas
OD
Water
Inlet/Outlet
Piping length
OU - IU Max.
Total piping length System Actual
Level difference OU - IU
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Geothermal operation
RWEYQ8T
8
22.4
5.07
4.42
25.0
5.94
4.21
4.42
4.21
5.07
5.94
HP
kW
kW
kW
kW
kW
kW
RWEYQ10T
10
28.0
4.56
6.14
31.5
5.25
6.00
6.14
6.00
4.56
5.25
36
100
200
260
mm
kg
dBA
dBA
°CDB
°CWB
125
250
325
1,000x780x550
137
137
-
50
51
10~45
10~45
R-410A
9.52
mm
mm
mm
19.1 (1)
22.2 (1)
15.9 (2) / 19.1 (3)
19.1 (2) / 22.2 (3)
PT1 1/4B internal thread/PT1 1/4B internal thread
120
300
50 (outdoor unit in highest position) / 40 (indoor unit in highest position)
3N~/50/380-415
20
m
m
m
Hz/V
A
WATER COOLED
VRV IV
OUTDOOR UNIT
Capacity range
Cooling capacity
Standard operation
(1) In case of heat pump system, gas pipe is not used (2) In case of heat recovery system (3) In case of heat pump system
OUTDOOR SYSTEM
System
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Capacity range
Cooling capacity Capacity
EER
PI
Heating capacity Capacity
EER
PI
Power input - 50Hz Cooling
Nom.
Heating
Nom.
EER
COP
Maximum number of connectable indoor units
Sound pressure level Cooling
Nom.
Piping
Liquid
OD
connections
Gas
OD
Discharge gas
OD
Piping length
OU - IU Max.
Total piping length System Actual
Level difference OU - IU
Current - 50Hz
Maximum fuse amps (MFA)
RWEYQ16T
RWEYQ18T
RWEYQ20T
RWEYQ8T
RWEYQ10T
RWEYQ8T
RWEYQ10T
HP
kW
kW
kW
kW
kW
kW
dBA
mm
mm
mm
m
m
m
A
16
44.8
5.07
8.8
50.0
5.94
8.4
9.10
8.48
4.92
5.87
18
50.4
4.77
10.6
56.5
5.53
10.2
10.6
10.3
4.63
5.48
53
12.7
20
56.0
4.56
12.3
63.0
5.25
12.0
12.1
12.1
4.41
5.21
54
15.9
RWEYQ24T
RWEYQ26T
RWEYQ8T
RWEYQ8T
RWEYQ8T
24
26
672
72.8
5.07
4.86
13.3
15.0
75.0
81.5
5.94
5.65
12.6
14.4
13.7
15.1
12.7
14.5
4.91
4.74
5.91
5.62
36
55
RWEYQ28T
RWEYQ30T
RWEYQ10T
RWEYQ10T
RWEYQ10T
28
30
78.4
84.0
4.69
4.56
16.7
18.4
88.0
94.5
5.43
5.25
16.2
18.0
16.6
18.1
16.3
18.2
4.57
4.43
5.40
5.19
56
19.1
28.6 (1)
34.9 (1)
22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3)
120
300
50 (outdoor unit in highest position) / 40 (indoor unit in highest position)
32
50
(1) In case of heat pump system, gas pipe is not used (2) In case of heat recovery system (3) In case of heat pump system
77
Indoor
units
As many as 64 separate indoor units can be operated from the single refrigerant circuit of a
54 HP VRV heat pump system. In fact, the Daikin VRV indoor unit range, one of the widest on
the market, currently comprises no less than 26 different stylish and elegant models in
116 different variants — all designed to maximise comfort, minimise operating noise and
simplify installation and servicing.
Designed to fit rooms of any size and shape, Daikin indoor units are also user friendly, quiet
running, ultra reliable, easy to control and supply users with that relaxing ‘extra something’
to the indoor climate.
From 01/2013 all indoor units will have to comply to the Ecodesign
legislation on fans. As a market leader Daikin takes the step to
be the first to comply with all indoors units to this legislation
by adopting DC fans in all indoor units, improving their energy
efficiency even further.
78
Ceiling suspended units
Concealed ceiling units
Floor standing units
Wall mounted units
Stylish indoor units
INDOOR
UNITS
Ceiling mounted cassettes
Benefits overview 80
Ceiling mounted cassettes
82
Concealed ceiling units
88
Wall mounted units
93
Ceiling suspended units
94
Floor standing units
96
Stylish indoor units 99
Hydroboxes for VRV108
Hydroboxes for VRV
79
Benefits overview
VRV indoor units
Ceiling mounted cassette
FXFQ-A
FXZQ-A
FXCQ-A
FXKQ-MA
FXDQ-M9
Inverter technology





Home leave operation





Fan only





Auto cleaning filter

Floor & presence sensor


Draught prevention


Auto cooling-heating changeover



Whisper quiet



Individual flap control


Ceiling soiling prevention




Vertical auto swing




Fan speed steps
3
3
3
2
2
Humidity
control
Dry programme





Air treatment
Air filter





Weekly timer





Infrared remote control





Wired remote control





Centralised control





Auto-restart





Self-diagnosis





Multi tenant


Standard
Standard
INVERTER
We care icons
Comfort
Air flow
Remote control & timer
Other funtions
Drain pump kit
80




Standard
Standard
Concealed ceiling unit
FXDQ-A
Wall mounted
unit
Ceiling suspended unit
Floor standing unit
FXSQ-P
FXMQ-P7
FXMQ-MA
FXAQ-P
FXHQ-A
FXUQ-A
FXNQ-P
FXLQ-P










































3
3
3
2
2
3
3
2
2













































































Standard
Standard
Standard

Optional
Optional
Optional
81
Standard
INDOOR
UNITS

Round flow cassette
Round flow cassette:
setting the standard
for efficiency and comfort
The round flow cassette is designed for use in all
forms and sizes of commercial offices & retail environments.
Today, Daikin has improved its technology even further to enhance
your comfort and provide you better energy efficient models.
presence sensor
floor sensor
Even more energy efficient…
With the optional infrared presence sensor the set point can be adjusted or the round flow cassette switched off when there is nobody in the room.
Up to 27% energy can be saved (estimated) with this new function. If no presence is detected in the room for 15mins, the set temperature is changed
until a minimum temperature (for heating) or maximum temperature (for cooling) is reached. When selecting the setback function, the unit will maintain
the temperature within a preset minimum and maximum temperature, when there is no presence detected in the room for 1 hour.
Without sensor
26°
Nobody in
the room
inside temperature (°CDB)
24°
22°
24°
22°
no presence detected for 15mins
0
0
.0
17
0
.3
16
0
.0
16
0
.3
15
0
.0
15
0
.3
14
0
.0
14
0
.3
13
0
.0
13
0
.3
12
0
.0
12
0
.3
11
0
.0
11
0
.3
10
.0
10
0
.3
.0
09
09
0
0
.0
17
0
.3
16
0
.0
16
0
.3
15
0
.0
15
0
.3
14
0
.0
14
0
.3
13
0
.0
13
0
.3
12
0
.0
12
0
.3
11
0
.0
11
0
.3
.0
10
10
0
0
.0
.3
09
09
time
0
20°
20°
time
Nobody in
the room
26°
… and improved comfort
• Daikin was the first to launch an auto-cleaning decoration
panel. With this panel the costs can be further reduced
as the filter cleans itself automatically once a day. Up to
50% energy can be saved thanks to daily filter cleaning.
• With the optional infrared floor sensor having cold feet will become
history. This sensor detects the average floor temperature and
ensures even temperature distribution between ceiling and floor.
•The presence sensor directs air flow away from any person detected
in the room, when the air flow control is on.
Test site, Wolverhampton, UK
Energy consumption (kWh)
ly
Ju
ne
Ju
ay
M
Standard round flow cassette
Flexible installation
When refurbishing or rearranging the interior of your office, shop or other area, you no longer need to change the location
of your indoor unit. With the round flow cassette one flap can be easily closed via the wired remote controller (BRC1E52A/B
– optional). Optional closure kits are available as well.
82
r il
ch
ar
y
M
Fe
b
ru
ar
y
ar
r
nu
ce
De
Auto cleaning cassette
Ja
m
be
be
r
r
m
ve
No
Oc
to
be
r
be
st
em
pt
Se
Au
Ju
ly
•The unique 360° airflow discharge pattern ensures a uniform
temperature distribution across the room without dead corners.
50%
difference in
electricity consumption
(Test site, Wolverhampton, UK)
Ap
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
gu
inside temperature (°CDB)
With sensor (BRC1E52A/B required)
Cooling
Set point: 22° CDB
Round flow cassette
FXFQ-A
FXFQ20-63A
››
››
››
››
››
››
››
››
››
››
››
››
››
››
presence sensor
BRC1E52A/BBRC7A532F
floor sensor
The round flow cassette provides a more comfortable environment and offers
greater savings in energy consumption to shop, office and restaurant owners
360° air discharge ensures uniform air flow and temperature distribution
Modern style decoration panel is available in 3 different variations: pure white
(RAL9010) auto cleaning panel, pure white (RAL9010) standard panel with
grey louvers and pure white (RAL9010) standard panel with white louvers
Daikin introduces first auto cleaning cassette to European market.
Higher efficiency and comfort thanks to daily auto cleaning of the filter.
Lower maintenance costs thanks to auto cleaning function.
Easy dust removal with vacuum cleaner without opening the unit.
The presence sensor (optional) adjusts the set point with standard 1°C if no
one is detected in the room, it is possible to adjust the set point with 2, 3 or
4°C (optional). It also automatically directs air flow away from any person to
avoid draught.
The floor sensor (optional) detects the average floor temperature and ensures
even temperature distribution between ceiling and floor. Cold feet will
become history.
Individual flap control: one flap can be easily closed via the wired remote
control (BRC1E52) in case you would refurbish or rearrange your interior
Low energy consumption thanks to specially developed small tube heat
exchanger, DC fan motor and drain pump
Fresh air intake: up to 20 %
Low installation height: 214mm for class 20-63
Standard drain pump with 850mm lift
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Decoration panel 2 Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Decoration panel 3 Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Sound power level Cooling
High/Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
mm
kg
mm
kg
mm
kg
m³/min
m³/min
dBA
dBA
dBA
mm
Hz/V
A
FXFQ20A
2.2
2.5
FXFQ25A
FXFQ32A
FXFQ40A
2.8
3.6
4.5
3.2
4.0
5.0
0.038
0.038
204x840x840
19
20
FXFQ50A
5.6
6.3
0.053
0.053
FXFQ63A
7.1
8.0
0.061
0.061
FXFQ80A
FXFQ100A
9.0
11.2
10.0
12.5
0.092
0.115
0.092
0.115
246x840x840
24
FXFQ125A
14.0
16.0
0.186
0.186
288x840x840
26
21
BYCQ140D7W1
Pure White (RAL 9010)
60x950x950
5.4
BYCQ140D7W1W
Pure White (RAL 9010)
60x950x950
5.4
BYCQ140D7GW1
Pure White (RAL 9010)
145x950x950
10.3
12.5/10.6/8.8
13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9
12.5/10.6/8.8
13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9
49/51/53/55/60/61/31/29/28
33/31/29
35/33/30
38/34/30
43/37/30
45/41/36
31/29/28
33/31/29
35/33/30
38/34/30
43/37/30
45/41/36
R-410A
6.35/12.7/VP25 (O.D. 32 / I.D. 25)
9.52/15.9/VP25 (O.D. 32 / I.D. 25)
1~/50/60/220-240/220
16
BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panel
The BYCQ140D7W1W has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt.
83
INDOOR
UNITS
850 mm
Fully flat cassette
Design & Genius
in one
Unique in the market, the fully flat cassette is a
remarkable blend of iconic design and engineering
excellence with an elegant white or a silver and
white finish. Fitting flush within the ceiling modules
and fully flat with the ceiling itself, the cassette is
both stylish and unobtrusive. Superb efficiency and
comfort is delivered through the combined use of
floor and presence sensors and, when necessary,
the individual flap control via the wired remote
controller makes it simple to close one flap.
84
FXZQ-A
Fully flat cassette
presence sensor
FXZQ-A (white panel)
››
››
››
››
››
››
››
››
BRC1E52A/B
BRC7F530W/S
Unique design in the market: integrates fully flat into the
ceiling and fits flush into architectural ceiling modules
Remarkable blend of iconic design and engineering excellence with
an elegant finish in white or a combination of silver and white
15 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc.
The presence sensor (optional) adjusts the set point with standard
1°C if no one is detected in the room, it is possible to adjust
the set point with 2, 3 or 4°C (optional). It also automatically
directs air flow away from any person to avoid draught.
The floor sensor (optional) detects the average floor
temperature and ensures even temperature distribution
between ceiling and floor. Cold feet will become history.
Individual flap control: one flap can be easily closed via the wired remote
control (BRC1E52) in case you would refurbish or rearrange your interior
Low energy consumption thanks to specially developed small
tube heat exchanger, DC fan motor and drain pump
Fresh air intake for healthy living
Standard drain pump with 850mm lift
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Decoration panel 2 Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Decoration panel 3 Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Sound power level Cooling
High/Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
FXZQ15A
1.7
1.9
FXZQ20A
2.2
2.5
0.043
0.036
FXZQ32A
3.6
4.0
0.045
0.038
260x575x575
15.5
mm
kg
mm
kg
mm
kg
m³/min
m³/min
dBA
dBA
dBA
FXZQ25A
2.8
3.2
8.5/7/6.5
8.5/7/6.5
8.7/7.5/6.5
8.7/7.5/6.5
49/-
31.5/28/25.5
31.5/28/25.5
32/29.5/25.5
32/29.5/25.5
mm
Hz/V
A
(1) Dimensions include control box
85
FXZQ40A
4.5
5.0
0.059
0.053
16.5
BYFQ60CW
White (N9.5)
46x620x620
2.8
BYFQ60B3
White (N9.5) + Silver
46x620x620
2.8
BYFQ60B2
White (RAL9010)
55x700x700
2.7
9/8/6.5
10/8.5/7
9/8/6.5
10/8.5/7
50/51/33/30/25.5
33.5/30/26
33/30/25.5
33.5/30/26
R-410A
6.35/12.7/VP20 (I.D. 20/O.D. 26)
1~/50/220-240
16
FXZQ50A
5.6
6.3
0.092
0.086
18.5
11.5/9.5/8
11.5/9.5/8
54/37/32/28
37/32/28
14.5/12.5/10
14.5/12.5/10
60/43/40/33
43/40/33
INDOOR
UNITS
››
floor sensor
FXZQ-A (silver and white panel)
FXCQ-A
2-way blow ceiling mounted cassette
FXCQ20_40A
››
››
››
››
››
››
››
BRC1E52A/B
BRC7CA52
Low energy consumption thanks to specially developed small
tube heat exchanger, DC fan motor and drain pump
Stylish unit blends easily with any interior, as the
flaps close entirely when not in operation
Improved comfort thanks to automatic air flow adjustment to required load
Individual flap control: one flap can be easily closed via the wired remote
control (BRC1E52) in case you would refurbish or rearrange your interior
Easy to install: depth of all units is 620mm
Maintenance operations can be performed by removing the front panel
Standard drain pump with 500mm lift
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing
Material
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate - 50Hz Cooling
High/Nom./Low
Sound power level Cooling
Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Air filter
Type
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
mm
kg
m³/min
dBA
dBA
dBA
mm
Hz/V
A
FXCQ20A
2.2
2.5
0.031
0.028
FXCQ25A
2.8
3.2
FXCQ32A
3.6
4.0
FXCQ40A
FXCQ50A
FXCQ63A
FXCQ80A
FXCQ125A
4.5
5.6
7.1
9.0
14.0
5.0
6.3
8.0
10.0
16.0
0.039
0.041
0.059
0.063
0.090
0.149
0.035
0.037
0.056
0.060
0.086
0.146
Galvanised steel plate
305x775x620
305x990x620
305x1,445x620
19
22
25
33
38
BYBCQ40HW1
BYBCQ63HW1
BYBCQ125HW1
Fresh white (6.5Y 9.5/0.5)
55x1,070x700
55x1,285x700
55x1,740x700
10
11
13
10.5/9/7.5
11.5/9.5/8
12/10.5/8.5
15/13/10.5
16/14/11.5
26/22.5/18.5
32/27.5/22.5
32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0
32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0
R-410A
6.35/12.7/VP25 (O.D. 32 / I.D. 25)
9.52/15.9/VP25 (O.D. 32 / I.D. 25)
Resin net with mold resistance
1~/50/220-240
16
86
FXKQ-MA
Ceiling mounted corner cassette
FXKQ-MA
››
››
BRC4C61
Compact dimensions, can easily be mounted in a
narrow ceiling void (only 220mm ceiling space required,
195 with panel spacer, available as accessory)
Optimum air flow conditions are created by either downward air discharge
or frontal air discharge (via optional grille) or a combination of both
Standard drain pump with 500mm lift
INDOOR
UNITS
››
BRC1E52A/B
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate - 50Hz Cooling
High/Low
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
FXKQ25MA
2.8
3.2
FXKQ32MA
3.6
4.0
FXKQ40MA
4.5
5.0
0.076
0.056
0.066
0.046
215x1,110x710
31
BYK45FJW1
FXKQ63MA
7.10
8.00
0.105
0.085
215x1,310x710
34
BYK71FJW1
White
mm
kg
m³/min
dBA
dBA
70x1,240x800
8.5
11/9
13/10
70x1,440x800
9.5
18/15
40.0/34.0
42.0/37.0
38.0/33.0
R-410A
mm
Hz/V
A
6.35/12.7/VP25 (O.D. 32 / I.D. 25)
1~/50/60/220-240/220
15
87
9.52/15.9/VP25 (O.D. 32 / I.D. 25)
FXDQ-M9
Small concealed ceiling unit
FXDQ-M9
››
››
››
››
››
BRC1E52A/B
BRC4C62
Designed for hotel bedrooms
Compact dimensions (230mm high & 652mm deep),
can easily be mounted in a ceiling void
Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible
The air suction direction can be altered from rear to bottom suction
For easy mounting, the drain pan can be
located to the left or right of the unit
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Required ceiling void >
Weight
Unit
Fan-Air flow rate Cooling
High/Low
- 50Hz
Heating
High/Low
Sound power level Cooling
Nom.
Sound pressure
Cooling
High/Low
level
Heating
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
mm
kg
m³/min
m³/min
dBA
dBA
dBA
FXDQ20M9
2.2
2.5
FXDQ25M9
2.8
3.2
0.050
0.050
Unpainted
230x502x652
250
17
6.7/5.2
6.7/5.2
7.4/5.8
7.4/5.8
50
37/32
37/32
R-410A
6.35/12.7/I.D. 21.6, O.D. 27.2
1~/50/230
16
mm
Hz/V
A
88
FXDQ-A
Slim concealed ceiling unit
FXDQ15-32A
››
››
››
››
››
BRC4C65
Compact dimensions, can easily be mounted
in a ceiling void of only 240mm
Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible
15 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc.
Low energy consumption thanks to DC inverter fans
Medium external static pressure facilitates unit use
with flexible ducts of varying lengths
Standard drain pump with 750mm lift
INDOOR
UNITS
››
BRC1E52A/B
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Required ceiling void >
Weight
Unit
Fan-Air flow rate - 50Hz Cooling
High/Nom./Low
Fan-External static pressure - 50Hz High/Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
mm
kg
m³/min
Pa
dBA
dBA
mm
Hz/V
A
FXDQ15A
1.7
1.9
7.5/7.0/6.4
50
32/31/27
FXDQ20A
2.2
2.5
FXDQ40A
FXDQ50A
4.5
5.6
5.0
6.3
0.071
0.078
0.099
0.068
0.075
0.096
Galvanised steel / Non painted
200x750x620
200x950x620
240
22
26
8.0/7.2/6.4
10.5/9.5/8.5
12.5/11.0/10.0
30/10
44/15
51
52
53
33/31/27
34/32/28
35/33/29
R-410A
6.35/12.7/VP20 (I.D. 20/O.D. 26)
1~/50/60/220-240/220
16
89
FXDQ25A
2.8
3.2
FXDQ32A
3.6
4.0
FXDQ63A
7.1
8.0
0.110
0.107
200x1,150x620
29
16.5/14.5/13.0
54
36/34/30
9.52/15.9/VP20 (I.D. 20/O.D. 26)
FXSQ-P, FXMQ-P7
Concealed ceiling unit with inverter driven fan
FXMQ20-32P7
FXSQ20-32P
››
››
››
››
››
››
››
››
BRC1E52A/B
BRC4C65
Easy installation thanks to automatic air flow adjustment towards nominal air flow rate
Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible
Up to 140Pa external static pressure (ESP) facilitates using flexible ducts of variying lengths: ideal for shops and medium size offices (FXSQ)
Up to 200Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas (FXMQ)
Low energy consumption thanks to DC inverter fans
Possibility to change ESP via wired remote control allows optimisation of the supply air volume
The air suction direction can be altered from rear to bottom suction
Standard built-in drain pump increases reliability of the drain system
Easy installation thanks to automatic air flow adjustment towards nominal air flow: Installation made easier
››
››
››
››
After installation, it is possible that the actual duct
resistance is lower than expected at time of designing.
As a consequence the air flow will be too high.
With the automatic air flow adjustment function the unit can
adapt its fan speed to a lower curve, so the air flow decreases.
The air flow will always be within 10% of the rated air flow because of the
amount of possible fan curves (more than 8 fan curves available per model).
Alternatively the installer can manually select a fan
curve with the wired remote control.
+/- 10%
External static pressure (Pa)
Reduced installation time
Fan characteristic curve
Actual duct resistance curve
Duct resistance curve at the time of designing
Rated air flow
Airflow without air flow automatic adjustment
Actual airflow
Air flow (m³/min)
+/- 10%
FXSQ-P - Medium static pressure
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Required ceiling void >
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Fan-External static pressure - 50Hz High/Nom.
Sound power level Cooling
Nom.
Sound pressure
Cooling
High/Low
level
Heating
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
mm
kg
mm
kg
m³/min
m³/min
Pa
dBA
dBA
dBA
mm
Hz/V
A
FXSQ20P FXSQ25P
2.2
2.8
2.5
3.2
0.041
0.029
FXSQ32P
3.6
4.0
0.044
0.032
FXSQ40P FXSQ50P FXSQ63P FXSQ80P FXSQ100P FXSQ125P FXSQ140P
4.5
5.6
7.1
9.0
11.2
14.0
16.0
5.0
6.3
8.0
10.0
12.5
16.0
18.0
0.097
0.074
0.118
0.117
0.185
0.261
0.085
0.062
0.106
0.105
0.173
0.249
Unpainted
300x550x700
300x700x700
300x1,000x700
300x1,400x700
350
23
26
35
46
47
BYBS32DJW1
BYBS45DJW1
BYBS71DJW1
BYBS125DJW1
White (10Y9/0.5)
55x650x500
55x800x500
55x1,100x500
55x1,500x500
3.0
3.5
4.5
6.5
19.5/17.8/16 25/22.5/20 32/27.5/23 39/33.5/28 46/39/32
9/7.8/6.5
9.5/8.3/7
16/13.5/11
19.5/17.8/16 25/22.5/20 32/27.5/23 39/33.5/28 46/39/32
9/7.8/6.5
9.5/8.3/7
16/13.5/11
70/30
100/30
100/40
120/40
120/50
140/50
55
56
63
59
63
61
66
67
32/26
33/27
37/29
37/30
38/32
40/33
42/34
32/26
33/27
37/29
37/30
38/32
40/33
42/34
R-410A
6.35/12.7/VP25 (O.D. 32 / I.D. 25)
9.52/15.9/VP25 (O.D. 32 / I.D. 25)
1~/50/60/220-240/220
16
90
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing
Colour
Material
HeightxWidthxDepth
Dimensions
Unit
Required ceiling void >
Weight
Unit
Decoration panel Model
Colour
HeightxWidthxDepth
Dimensions
Weight
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Fan-External static pressure - 50Hz High/Nom.
Sound power level Cooling
High/Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Air filter
Type
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
mm
kg
mm
kg
m³/min
m³/min
Pa
dBA
dBA
dBA
mm
Hz/V
A
FXMQ20P7 FXMQ25P7
2.2
2.8
2.5
3.2
0.049
0.037
FXMQ32P7
3.6
4.0
0.053
0.041
INDOOR
UNITS
FXMQ-P7-High static pressure
FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7
5.6
7.1
9.0
11.2
14.0
6.3
8.0
10.0
12.5
16.0
0.110
0.120
0.171
0.176
0.241
0.098
0.108
0.159
0.164
0.229
Unpainted
Galvanised steel plate
300x550x700
300x700x700
300x1,000x700
300x1,400x700
350
23
26
35
46
BYBS32DJW1
BYBS45DJW1
BYBS71DJW1
BYBS125DJW1
White (10Y9/0.5)
55x650x500
55x800x500
55x1,100x500
55x1,500x500
3.0
3.5
4.5
6.5
9/7.8/6.5
9.5/8.3/7
16/13.5/11
18/16.5/15 19.5/17.8/16 25/22.5/20
32/27.5/23
39/33.5/28
9.0/7.8/6.5
9.5/8.3/7
16/13.5/11
18/16.5/15 19.5/17.8/16 25/22.5/20
32/27.5/23
39/33.5/28
100/50
160/100
200/100
56/57/65/61/64/67/65/70/33/31/29
34/32/30
39/37/35
41/39/37
42/40/38
43/41/39
44/42/40
33/31/29
34/32/30
39/37/35
41/39/37
42/40/38
43/41/39
44/42/40
R-410A
6.35/12.7/VP25 (I.D. 25/O.D. 32)
9.52/15.9/VP25 (I.D. 25/O.D. 32)
Resin net with mold resistance
1~/50/60/220-240/220
16
91
FXMQ40P7
4.5
5.0
0.151
0.139
FXMQ-MA
Large concealed ceiling unit
FXMQ-MA
››
››
››
BRC1E52A/B
BRC4C65
Up to 270Pa external static pressure allows extensive ductwork
runs and flexible application: ideal for use in large areas
Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible
Up to 31.5kW in heating mode
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate - 50Hz Cooling
High/Low
Fan-External static pressure - 50Hz High/Nom.
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
Pa
dBA
dBA
mm
Hz/V
A
FXMQ200MA
22.4
25.0
1.294
1.294
FXMQ250MA
28.0
31.5
1.465
1.465
470x1,380x1,100
137
58/50
221/132
72/62
270/191
48/45
R-410A
9.52/19.1/PS1B
9.52/22.2/PS1B
1~/50/60/220-240/220
15
92
FXAQ-P
Wall mounted unit
FXAQ15-32P
››
››
››
››
››
BRC7E618
Ideal solution for shops, restaurants or offices
with no or narrow false ceilings
Low energy consumption thanks to DC fan motor
Can be installed in both new and existing buildings
Flat, stylish front panel blends easily within any
interior décor and is more easy to clean
15 class unit especially developed for small or well-insulated
rooms, such as hotel bedrooms, small offices, etc.
5 different discharge angles can be programmed via the remote control
Maintenance operations can be performed from the front of the unit
INDOOR
UNITS
››
››
BRC1E52A/B
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate - 50Hz Cooling
High/Low
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
dBA
dBA
FXAQ15P
1.7
1.9
0.017
0.025
7.0/4.5
34.0/29.0
FXAQ20P
2.2
2.5
0.019
0.029
FXAQ25P
2.8
3.2
0.028
0.034
290x795x238
11
7.5/4.5
8/5
35.0/29.0
mm
Hz/V
A
93
FXAQ32P
FXAQ40P
3.6
4.5
4.0
5.0
0.030
0.020
0.035
0.020
White (3.0Y8.5/0.5)
8.5/5.5
36.0/29.0
37.5/29.0
R-410A
6.35/12.7/VP13 (I.D. 13/O.D. 18)
1~/50/220-240
16
FXAQ50P
5.6
6.3
0.033
0.039
FXAQ63P
7.1
8.0
0.050
0.060
12/9
290x1,050x238
14
15/12
19/14
39.0/34.0
42.0/36.0
47.0/39.0
9.52/15.9/VP13 (I.D. 13/O.D. 18)
FXHQ-A
Ceiling suspended unit
FXHQ100A
››
››
BRC1E52A/B
BRC7G53
››
››
Ideal solution for commercial spaces with narrow or no false ceilings
The unit can easily be mounted in corners and narrow
spaces, as it only needs 30mm lateral service space
Low energy consumption thanks to DC fan motor and drain pump
Stylish unit blends easily with any interior, as the
flaps close entirely when not in operation
Can be installed in both new and existing buildings
Wider air discharge thanks to Coanda effect: up to 100°
››
Air flow distribution for ceiling heights up to 3.8m without capacity loss
››
››
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Sound power level Cooling
Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
m³/min
dBA
dBA
dBA
mm
Hz/V
A
FXHQ32A
3.6
4.0
0.107
0.107
235x960x690
24
14.0/12.0/10.0
14.0/12.0/10.0
36.0/34.0/31.0
36.0/34.0/31.0
6.35/12.7/VP20 (I.D. 20/O.D. 26)
94
FXHQ63A
FXHQ100A
7.1
11.2
8.0
12.5
0.111
0.237
0.111
0.237
Fresh White
235x1,270x690
235x1,590x690
33
39
20.0/17.0/14.0
29.5/24.0/19.0
20.0/17.0/14.0
29.5/24.0/19.0
37.0/35.0/34.0
44.0/37.0/34.0
37.0/35.0/34.0
44.0/37.0/34.0
R-410A
9.52/15.9/VP20 (I.D. 20/O.D. 26)
1~/50/220-240
16
FXUQ-A
4-way blow ceiling suspended unit
FXUQ-A
››
››
››
››
››
››
BRC7C58
Ideal solution for commercial spaces with narrow or no false ceilings
Separate BEVQ box is no longer needed: the expansion
valve is integrated in the indoor unit.
Low energy consumption thanks to DC fan motor and drain pump
Stylish unit blends easily with any interior, as the
flaps close entirely when not in operation
Improved comfort thanks to automatic air flow adjustment to required load
Individual flap control: one flap can be easily closed via the wired remote
control (BRC1E52) in case you would refurbish or rearrange your interior
Can be installed in both new and existing buildings
Same outlook for all models (unified dimensions)
Air can be discharged in 5 different angles between 0 and 60°
Air flow distribution for ceiling heights up to 3.5m without capacity loss
Standard drain pump with 500mm lift
INDOOR
UNITS
››
››
››
››
››
BRC1E52A/B
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate Cooling
High/Nom./Low
- 50Hz
Heating
High/Nom./Low
Sound power level Cooling
Nom.
Sound pressure
Cooling
High/Nom./Low
level
Heating
High/Nom./Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
m³/min
dBA
dBA
dBA
FXUQ71A
8.0
9.0
0.090
0.073
FXUQ100A
11.2
12.5
0.200
0.179
Fresh White
198x950x950
26
22.5/19.5/16.0
22.5/19.5/16.0
27
31.0/26.0/21.0
31.0/26.0/21.0
-
40.0/38.0/36.0
40.0/38.0/36.0
47.0/44.0/40.0
47.0/44.0/40.0
R-410A
9.52/15.9/I.D. 20/O.D. 26
1~/50/60/220-240/220-230
16
mm
Hz/V
A
95
FXNQ-P
Concealed floor standing unit
FXNQ20-25P
››
››
››
››
BRC1E52A/B
BRC4C65
Its low height enables the unit to fit perfectly beneath a window
Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible
Requires very little installation space
The connecting port faces downward, eliminating
the need to attach auxiliary piping
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate - 50Hz Cooling
High/Low
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
dBA
dBA
FXNQ20P
2.2
2.5
FXNQ25P
2.8
3.2
0.049
0.049
610x930x220
19
7/6
FXNQ32P
3.6
4.0
FXNQ40P
4.5
5.0
FXNQ50P
5.6
6.3
0.090
0.090
610x1,070x220
23
8/6
FXNQ63P
7.1
8.0
0.110
0.110
610x1,350x220
27
11/8.5
14/11
16/12
38/33
R-410A
6.35/12.7/O.D. 21
1~/50/60/220-240/220
15
39/34
40/35
35/32
mm
Hz/V
A
96
9.52/15.9/O.D. 21
FXLQ-P
Floor standing unit
FXLQ20-25
››
››
››
››
››
Stylish modern casing finished in pure white
(RAL9010) and iron grey (RAL7011)
Unit can be installed as free standing model by use of optional back plate
Its low height enables the unit to fit perfectly beneath a window
Requires very little installation space
Wall mounted installation facilitates cleaning beneath
the unit where dust tends to accumulate
Wired remote control can easily be integrated in the unit
INDOOR
UNITS
››
BRC7C62
BRC1E52A/B
INDOOR UNIT
Cooling capacity Nom.
Heating capacity Nom.
Power input - 50Hz Cooling
Nom.
Heating
Nom.
Casing Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate - 50Hz Cooling
High/Low
Sound power level Cooling
Nom.
Sound pressure level Cooling
High/Low
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD/Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
kW
kW
kW
kW
mm
kg
m³/min
dBA
dBA
FXLQ20P
2.2
2.5
FXLQ25P
2.8
3.2
0.049
0.049
600x1,000x232
27
7/6
35/32
mm
Hz/V
A
97
FXLQ32P
3.6
4.0
FXLQ40P
4.5
5.0
0.090
0.090
Fresh white (RAL9010) / Dark grey (RAL7011)
600x1,140x232
32
8/6
11/8.5
38/33
R-410A
6.35/12.7/O.D. 21
1~/50/60/220-240/220
15
FXLQ50P
5.6
6.3
FXLQ63P
7.1
8.000
0.110
0.110
600x1,420x232
38
14/11
16/12
39/34
40/35
9.52/15.9/O.D. 21
98
Stylish indoor unit range
for connection
to VRV IV and VRV III-S
Connectable
outdoor unit
Capacity
Round flow cassette
(incl. autocleaning function1)
FCQG-F

FFQ-C

Fully flat cassette
WALL MOUNTED
CEILING
SUSPENDED
15
20
25
35
42
50
60
71
Small concealed ceiling unit FDBQ-B

Slim concealed ceiling unit FDXS-F(9)

Concealed ceiling unit
with inverter driven fan

FBQ-C8
FTXG-LW/
LS


Wall mounted unit
CTXS-K
FTXS-K


Wall mounted unit
FTXS-G


Ceiling suspended unit
FHQ-C
Wall mounted unit

FVXG-K


Floor standing unit
FVXS-F


Flexi type unit
FLXS-B(9)


Nexura floor standing unit
FLOOR STANDING
RXYSQ-P8V1
RXYSQ-P8Y1
Product
name
Daikin Emura
new
RYYQ-T
RXYQ-T
Model
99
INDOOR
UNITS
CONCEALED CEILING
CEILING MOUNTED
CASSETTE
Type
Fall in love with Daikin Emura.
Daikin Emura is re­fined on the outside and smart on the inside. Built-in intelligence and
innovative features en­sure low energy consumption. Its smart sensors provide optimal
performances for year round comfort. Still, you’re always in control via the easy-to-use remote
controller and the smartphone app with intuitive interface. You see... The new Daikin Emura
has everything to fall in love with.
Find out more on www.daikinemura.eu
100
FTXG-LW/S / RXG-L
FTXG-LW/S
››
››
››
››
RXG-L
emura
ARC466A1
Remarkable blend of iconic design and engineering excellence
with an elegant finish in matt crystal white or silver
Completely new European design, while keeping the
identity of the 1st generation Daikin Emura.
SEER up to A+++
Whisper quiet in operation: the operating of the unit can hardly be
heard. The sound pressure level goes down to 19dBA!
Online controller (optional): control your indoor unit from
any location via smartphone or tablet.
INDOOR
UNITS
››
Wall mounted unit
Heating & Cooling
INDOOR UNIT
Cooling capacity
Heating capacity
Power input
Min./Nom./Max.
Min./Nom./Max.
Cooling
Min./Nom./Max.
Heating
Min./Nom./Max.
Casing
Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
High/Nom./Low/Silent operation
Fan - Air flow rate Cooling
High/Nom./Low/Silent operation
Heating
Sound power level Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure
Cooling
level
High/Nom./Low/Silent operation
Heating
Piping
Liquid
OD
connections
Gas
OD
Drain
OD
Power supply
Phase / Frequency / Voltage
kW
kW
kW
kW
mm
kg
m³/min
m³/min
dBA
dBA
dBA
dBA
mm
mm
mm
Hz / V
FTXG20LW
FTXG20LS
1.3 /-/2.8
1.3 /-/4.3
0.32 /0.501 /0.76
0.31 /0.50 /1.12
White
Silver
FTXG25LW
FTXG25LS
FTXG35LW
FTXG35LS
1.3 /-/3.0
1.4 /-/3.8
1.3 /-/4.5
1.4 /-/5.0
0.32 /0.523 /0.82
0.35 /0.882 /1.19
0.31 /0.769 /1.32
0.32 /0.985 /1.49
White
Silver
White
Silver
303x998x212
12
8.9/6.6/4.4/2.6
10.9/7.8/4.8/2.9
10.2/8.4/6.3/3.8
11.0/8.6/6.3/3.8
12.4/9.6/6.9/4.1
54
59
56
59
38/32/25/19
45/34/26/20
40/34/28/19
41/34/28/19
45/37/29/20
6.35
9.5
18
1~ / 50 / 220-240
(1) EER/COP according to Eurovent 2012, for use outside EU only.
101
FTXG50LW
FTXG50LS
1.7 /-/5.3
1.7 /-/6.5
0.37 /1.360 /1.88
0.31 /1.589 /2.49
White
Silver
10.9/8.9/6.8/3.6
12.6/10.5/8.1/5.0
60
60
46/40/35/32
47/41/35/32
12.7
FTXS-K & CTXS-K
Optimal
design and
comfort
Integrated design
›› Discreet, modern design. Its smooth curve blends
beautifully with the wall resulting in an unobtrusive
presence that matches all interior décors.
› High quality matt crystal white finish.
›› New remote controller design, in the same high
quality matt white finish to create a perfect
match with the indoor unit.
Top performance
The FTXS-K series delivers top performance and are equipped with
a weekly timer and intelligent eye to generate further energy
savings. The weekly timer allows you to programme your unit so
that it best suits your needs, whereas the intelligent eye detects the
presence of people in the room and activates the economy mode
when no one is there.
The right indoor for the right room
We have a full range of wall units to provide optimal design and comfort in any room.
Our small wall mounted units (CTXS15,35K and FTXS20,25K) are optimised for small offices or hotel bedrooms.
›› Recognising the trend for less spacious rooms or offices and better insulation, we extended our range with the 15 class to deliver exactly the
right comfort in smaller rooms.
›› In general, silence is even more important in bedrooms than in other areas: our small wall mounted series go almost unnoticed with operating
sound levels as low as 19dBA
Our larger wall mounted units (FTXS35, 42, 50K) deliver perfect comfort to your larger area's.
››
››
››
The new discharge air pattern - using the `Coanda effect’ - provides a greater airflow length ensuring perfect comfort in every corner of the room.
The two-area intelligent eye detects where people are located in the room and can project the airflow away from the occupants to avoid
direct draught.
To optimize comfort even further the new wall mounted series are whisper quiet.
102
FTXS-K/G / RXS-K/F
FTXS20-25K//CTXS15-35K
››
››
››
››
››
››
ARC466A6
Discreet, modern design. Its smooth curve blends
beautifully with the wall resulting in an unobtrusive
presence that matches all interior décors.
High quality matt crystal white finish
Whisper quiet in operation: the operating of the unit can hardly
be heard. The sound pressure level goes down to 19dBA!
Ideal for installation in small or well insulated rooms (20,25
class) and larger or irregular shaped areas (35,42,50 class)
2 area intelligent eye: air flow is sent to a zone other than where
the person is located at that moment.
If no people are detected, the unit will automatically switch
over to the energy-efficient setting. (FTXS35,42,50K)
Online controller (optional): control your indoor
unit from any location via smartphone, laptop, pc,
tablet or touch screen (FTXS35,42,50,60,71)
Improved air discharge pattern, using the Coanda effect
INDOOR
UNITS
››
Wall mounted unit
Heating & Cooling
INDOOR UNIT
Casing
Dimensions
Weight
Fan - Air flow rate
Colour
HeightxWidthxDepth
Unit
Unit
High/Nom./Low/Silent operation
Cooling
Heating
High/Nom./Low/Silent operation
Sound power level Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure
Cooling
level
High/Nom./Low/Silent operation
Heating
Piping
Liquid
OD
connections
Gas
OD
Drain
OD
Power supply
Phase / Frequency / Voltage
CTXS15K
mm
kg
m³/min
m³/min
dBA
dBA
dBA
dBA
mm
mm
mm
Hz / V
7.9/6.3/4.7/3.9
9.0/7.5/6.0/4.3
55
56
37/31/25/21
38/33/28/21
CTXS35K
FTXS20K
FTXS25K
FTXS35K
White
289x780x215
8
9.2/7.2/5.2/3.9 8.8/8.8/4.7/3.9 9.1/9.1/5.0/3.9
10.1/8.1/6.3/4.3 9.5/7.8/6.0/4.3 10.0/8.0/6.0/4.3
59
58
58
42/35/28/21 40/32/24/19 41/33/25/19
41/36/30/21 40/34/27/19 41/34/27/19
298x900x215
11
11.2/11.2/5.8/4.1 11.2/11.2/7.0/4.1
12.1/9.3/6.5/4.2 12.4/10.0/7.8/5.2
59
59
45/37/29/19 45/39/33/21
45/39/29/19 45/39/33/22
6.35
9.5
FTXS50K
FTXS60G
FTXS71G
290x1,050x250
12
11.9/11.9/7.4/4.5 16.0/16.0/11.3/10.1 17.2/17.2/11.5/10.5
13.3/10.8/8.4/5.5 17.2/14.9/12.6/11.3 19.5/16.7/14.2/12.6
60
63
60
59
62
46/40/34/23 45/41/36/33 46/42/37/34
47/40/34/24 44/40/35/32 46/42/37/34
12.7
18
1~ / 50 / 220-240
103
FTXS42K
15.9
Logo grijs
The best of two
worlds united
Pure comfort and
design
Comfort is key
Nexura makes your world a comfortable one.
The coolness of a summer breeze or the cosiness
of an extra heat source brings a feeling of wellbeing all year round. Its unobtrusive yet stylish
design with a front panel that radiates additional
heat, its low noise level and reduced air flow turn
your space into a haven.
radiant
heat
104
FVXG-K/RXLG-K
Floor standing unit with radiant heat panel
radiant
heat
FVXG-K
››
››
››
››
››
The aluminium part of the front panel of the Nexura indoor
unit has the capability of warming up, just like a traditional
radiator, to add even more comfort on cold days
Quiet and discrete, Nexura offers you the best in
heating and cooling, in comfort and design
The indoor unit distributes air at the sound of a whisper.
The noise produced amounts to barely 22dB(A) in cooling and
19dB(A) in radiant heat mode. In comparison, the ambient
sound in a quiet room amounts to 40dB(A) on average.
Comfortable vertical auto swing ensures draughtfree
operation and prevents ceiling soiling
Online controller (optional): control your indoor unit from any
location via smartphone, laptop, pc, tablet or touch screen
Can be installed against a wall or recessed
INDOOR
UNITS
››
ARC466A2
Heating & Cooling
INDOOR UNIT
Casing
Dimensions
Weight
Fan - Air flow rate
Colour
HeightxWidthxDepth
Unit
Unit
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure
Cooling
level
High/Nom./Low/Silent operation
Heating
Piping
Liquid
OD
connections
Gas
OD
Power supply
Phase / Frequency / Voltage
FVXG25K
mm
kg
m³/min
m³/min
dBA
dBA
dBA
dBA
mm
mm
Hz / V
FVXG35K
Fresh white (6.5Y 9.5/0.5)
600x950x215
22
9.1/9.1/5.3/4.5
10.2/8.0/5.8/5.0
8.9/8.9/5.3/4.5
9.9/7.8/5.7/4.7
52
53
38/32/26/23
39/32/26/22/19
39/33/27/24
40/33/27/23/19
6.35
9.5
10.6/10.3/7.3/6.0
12.2/10.0/7.8/6.8
58
60
44/40/36/32
46/40/34/30/26
12.7
1~ / 50 / 220-240
105
FVXG50K
FVXS-F / RXS-K
FVXS-F
››
››
››
››
››
Floor standing unit
ARC452A1
Its low height enables the unit to fit perfectly beneath a window
Can be installed against a wall or recessed
Whisper quiet operation: down to 23dBA sound pressure level
Vertical auto swing moves the discharge flaps up and down for
efficient air and temperature distribution throughout the room
Online controller (optional): control your indoor unit from any
location via smartphone, laptop, pc, tablet or touch screen
Heating & Cooling
INDOOR UNIT
Casing
Dimensions
Weight
Fan - Air flow rate
Colour
HeightxWidthxDepth
Unit
Unit
High/Nom./Low/Silent operation
Cooling
High/Nom./Low/Silent operation
Heating
Sound power level Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure
Cooling
level
High/Nom./Low/Silent operation
Heating
Piping
Liquid
OD
connections
Gas
OD
Drain
OD
Power supply
Phase / Frequency / Voltage
FVXS25F
mm
kg
m³/min
m³/min
dBA
dBA
dBA
dBA
mm
mm
mm
Hz / V
FVXS35F
White
600x700x210
14
8.5/8.5/4.9/4.5
9.4/7.3/5.2/4.7
8.2/8.2/4.8/4.1
8.8/6.9/5.0/4.4
52
52
38/32/26/23
38/32/26/23
39/33/27/24
39/33/27/24
6.35
9.5
10.7/10.7/7.8/6.6
11.8/10.1/8.5/7.1
60
60
44/40/36/32
45/40/36/32
12.7
20
1~ / 50 / 220-240
106
FVXS50F
FLXS-B(9) / RXS-K
FLXS-B
››
››
ARC433A6
FLXS-B
Can fit on either ceiling or lower wall; its low height
enables the unit to fit beneath a window
Vertical auto swing moves the discharge flaps up and down
for efficient air and temperature distribution throughout the room
Whisper quiet operation: down to 28dBA sound pressure level
Online controller (optional): control your indoor unit from any
location via smartphone, laptop, pc, tablet or touch screen
INDOOR
UNITS
››
››
Flexi type unit
Heating & Cooling
INDOOR UNIT
Casing
Colour
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
High/Nom./Low/Silent operation
Fan - Air flow rate Cooling
High/Nom./Low/Silent operation
Heating
Sound power level Cooling
Heating
High/Nom./Low/Silent operation
Sound pressure
Cooling
level
High/Nom./Low/Silent operation
Heating
Piping
Liquid
OD
connections
Gas
OD
Drain
OD
Power supply
Phase / Frequency / Voltage
FLXS25B
mm
kg
m³/min
m³/min
dBA
dBA
dBA
dBA
mm
mm
mm
Hz / V
FLXS35B9
FLXS50B
FLXS60B
Almond white
490x1,050x200
16
7.6/7.6/6.0/5.2
9.2/8.3/7.4/6.6
51
51
37/34/31/28
37/34/31/29
17
8.6/7.6/6.6/5.6
12.8/10.4/8.0/7.2
53
59
38/35/32/29
46/36/33/30
11.4/11.4/8.5/7.5
12.1/9.8/7.5/6.8
12.0/10.7/9.3/8.3
12.8/10.6/8.4/7.5
60
47/43/39/36
46/41/35/33
59
48/45/41/39
47/42/37/34
6.35
9.5
18.0
12.7
20
1~ / 50 / 220-240
107
18
HXY-A
HXY-A
Low temperature hydrobox for VRV
HXY-A
››
››
››
››
››
››
››
››
››
Highly efficient space heating/cooling
Air to water connection to VRV for applications such as
underfloor, AHU, low temperture radiators, …
Leaving water temperature range from 5°C to 45°C without electric heater
Super wide operating range for cold/hot water production
from -20 to +43°C ambient outdoor temperature
Saves time on system design as all water-side components are fully
integrated with direct control over leaving water temperature
Saves space with contemporary wall hung design
Requires no gas connection or oil tank
Connectable to VRV IV heat pump and heat recovery
Liquid pipe
Gas pipe
F1, F2 communication
Hot/cold water
VRV indoor units
Air handling unit
Low temp.
radiator
Under floor
heating
VRV IV heat pump
INDOOR UNIT
Cooling capacity
Heating capacity
Casing
Nom.
Nom.
Colour
Material
Dimensions
Unit
Weight
Unit
Sound pressure level Nom.
Operation range Heating
Cooling
kW
kW
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Refrigerant
Type
Refrigerant circuit Gas side diameter
Liquid side diameter
Water circuit
Piping connections diameter
Power supply
Phase/Frequency/Voltage
Recommended fuses
HXY080A
8
9
HXY125A
12.5
14
White
Precoated sheet metal
890x480x344
44
-20~24
25~45
10~43
5~20
R-410A
15.9
9.5
G 1”1/4 (female)
1~/50/220-240
6~16
mm
kg
dBA
°C
°C
°C
°C
mm
mm
inch
Hz/V
A
108
HXHD-A
HXHD-A
››
››
››
››
››
High temperature hydrobox for VRV
EKHTS-AC
EKHWP-B
››
Air to water connection to VRV for applications such as bathrooms,
sinks, underfloor heating, radiators and air handling units
Free heating provided by transferring heat from areas
requiring cooling to areas requiring heating or hot water
Uses heat pump technology to produce hot water efficiently,
providing up to 17% savings compared to a gas boiler
Possibility to connect thermal solar collectors
to the domestic hot water tank
Leaving water temperature range from 25
to 80°C without electric heater
Hot water production
and heating:
maximum savings
by heat recovery
Cooling demand
Heating demand
Hot water demand
››
››
››
››
››
0 500010000 15000 200002500030000
Jan
Partial
heat recovery
Super wide operating range for hot water production
from -20 to +43°C ambient outdoor temperature
Saves time on system design as all water-side components are fully
integrated with direct control over leaving water temperature
Various control possibilities with weather
dependant set point or thermostat control
The indoor unit and domestic hot water tank can be stacked to save
space, or installed next to each other, if only limited height is available
Requires no gas connection or oil tank
Connectable to VRV IV heat recovery (REYQ-T)
and VRV III heat recovery (REAYQ-P)
Feb
Mar
Apr
May
Jun
Hot water and heating
virtually for free
thanks to heat recovery
Jul
Aug
Sep
Oct
Heat recovery
Nov
Partial
heat recovery
Dec
45°C - 75°C
Liquid pipe
Gas pipe
Discharge gas pipe
F1, F2 communication
Hot water
Domestic hot
water
VRV indoor units
Air handling
unit
25°C - 75°C
Domestic hot
water tank
45°C - 75°C
BS-Box
Heating only
hydrobox for VRV
VRV heat recovery with
connection to heating
only hydrobox
(REYAQ10-16P)
INDOOR UNIT
Heating capacity
Nom.
Colour
Casing
Material
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Nom.
Sound pressure
level
Night quiet mode Level 1
Ambient Min.~Max.
Heating
Water side Min.~Max.
Operation range
Ambient Min.~Max.
Domestic hot
water
Water side Min.~Max.
Refrigerant
Type
Gas side diameter
Refrigerant circuit
Liquid side diameter
Piping connections diameter
Water circuit
Heating water system Water volume Min.~Max.
Power supply
Phase/Frequency/Voltage
Current
Recommended fuses
Under floor
heating
25°C - 35°C
HXHD125A
14.0
Metallic grey
Precoated sheet metal
705x600x695
92
42 (1) / 43 (2)
38 (1)
-20~20 / 24 (3)
25~80
-20~43
45~75
R-134a
12.7
9.52
G 1” (female)
20~200
1~/50/220-240
20
kW
mm
kg
dBA
dBA
°C
°C
°CDB
°C
mm
mm
inch
l
Hz/V
A
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting
109
Low temp.
radiator
HOT WATER
BS-Box
HXHD-A
Accessories
Domestic hot water tank: Overview
1/ EKHTS-AC
Functions
Domestic hot water only
Domestic hot water –
possibility for solar connection
The water stored in the tank is used
for domestic hot water
Domestic hot water is not
stored in the tank but
flows through the tank’s coil
Preferred application
Operation
2/ EKHWP-B
1. EKHTS – domestic hot water only
››
››
››
Available in 200 and 260 litres
Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes
Stainless steel domestic hot water tank
INDOOR UNIT
Casing
Dimensions
Weight
Tank
Heat exchanger
EKHTS200AC
Colour
Material
Unit
EKHTS260AC
Metallic grey
Galvanised steel (precoated sheet metal)
Height(Integrated on
mm
indoor unit)xWidthxDepth
Empty
kg
l
Unit
Water volume
Material
Maximum water temperature
Quantity
Tube material
Face area
Internal coil volume
2,010x600x695
2,285x600x695
70
200
78
260
Stainless steel (EN 1.4521)
75
1
Duplex steel (EN 1.4162)
1.56
7.5
°C
m²
l
110
2. EKHWP-B –
Domestic hot water with possibility for solar connection
Solar connection
››
››
››
››
Environmentally friendly and energy efficient
Solar panels can produce up to 70% of the energy needed for hot water production – a major cost saving
Specialised coatings make our solar panels highly energy efficient – all shortwave solar energy is transferred into heat
The solar panels are charged with water only when needed for heating – avoiding the need for ‘anti-freeze’ protection
SOLAR COLLECTOR
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Volume
Surface
Outer
Aperture
Absorber
Coating
Absorber
Glazing
Allowed roof angle Min.~Max.
Operating pressure Max.
Stand still temperature Max.
Thermal performance Zero loss collector efficiency η0
Installed position
mm
kg
l
m²
m²
m²
°
bar
°C
%
EKSH26P
EKSV21P
EKSV26P
1,300x2,000x85
2,000x1,006x85
2,000x1,300x85
42
35
42
2.1
1.3
1.7
2.6
2.01
2.6
2.350
1.79
2.35
2.360
1.8
2.36
Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)
Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Single pane safety glass, transmission +/- 92%
15~80
6
200
Horizontal
Vertical
Domestic hot water tank
Available in 300 and 500 litres
(Pre-)heat the water for your heating system with solar energy
DOMESTIC HOT WATER TANK
Dimensions
Unit
Weight
Tank
Heat exchanger
Height
Width
Depth
Empty
Unit
Water volume
Maximum water temperature
Insulation
Heat loss
Domestic hot
Tube material
water
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Charging
Tube material
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Auxiliary solar Tube material
heating
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
EKHWP300B
1,640
595
615
59
300
mm
mm
mm
kg
l
°C
kWh/24h
EKHWP500B
1,640
790
790
93
500
85
1.3
1.4
Stainless steel
m²
l
bar
W/K
5.8
27.9
6
29
6
2,790
2,900
Stainless steel
m²
l
bar
W/K
2.7
13.2
3.8
18.5
3
1,300
1,800
Stainless steel
m²
l
bar
W/K
-
0.5
2.3
3
-
Pump station
››
The pump station ensures that the correct water pressure and flow rates are maintained for optimum efficiency
INDOOR UNIT
Mounting
HeightxWidthxDepth
Dimensions
Unit
Thermal performance Zero loss collector efficiency η0
Control
Type
Power consumption
Sensor
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
Power supply
Voltage
mm
%
W
V
EKSRPS3
On side of tank
815x230x142
Digital temperature difference controller with plain text display
2
Pt1000
PTC
PTC
Voltage signal (3.5V DC)
230
111
280
HOT WATER
››
››
Biddle
connected to
Benefits of
Daikin Heat Pumps
Biddle air curtains provide highly efficient solutions for retailers and consultants to combat
the issue of climate separation across their outlet or office doorway.
‘Open Door’ Trading
Although the customer friendly aspects of open door trading are widely appreciated by
retail and commercial outlet managers, open doors can also give rise to massive losses
in conditioned warm or cold air and hence, energy. Biddle air curtains however, not only
preserve indoor temperatures and generate significant economies, they also represent
an invitation for customers, to enter a pleasant trading and working environment.
High efficiency and low CO2 emission
An efficient outdoor/indoor climate separation limits heat loss through the door opening
and enhances the efficiency of the air conditioning system. Combining Biddle air curtains
with Daikin heat pumps can lead to savings up to 72% compared to electric air curtains and
a paypack period of less than 1.5 years!
112
Air Curtains
Which air curtain offers me the best solution?
Biddle air curtains come in 2 versions, one to connect to VRV end one for connection to ERQ. Both of them ar available in varying door
widths from 1 up to 2.5 meters. Below you can find an overview of the different versions and available door heights.
Biddle air curtain for connection to VRV (CYV) or to ERQ (CYQ)
Biddle comfort air curtain range
Free-Hanging (F)
4
Door height (m)
3.8m
3.5m
3.3m
3.0m
2.8m
3
3.0m
2.5m
2.5m
2.4m
2.2m
2.2m
2
Cassette (C)
1
S
M
L
XL
S
M
L
Normal
Favourable
ex: covered shopping mall or
revolving door entrance
XL
ex: little direct wind, no
opposite open doors, building
with ground floor only
M
L
Unfavourable
XL
Installation condition
ex: location at a corner or
square, multiple floors
and / or open stairwell
Biddle comfort air curtian nomenclature
CA V S 150 DK 80 F S C
Controller (standard)
Color. B=White (RAL6010), S: Grey (RAL9006)
Installation type: F=Freehanging, C=Cassette, R=Recessed
Capacity class (kW)
Daikin direct expansion
Door width (cm)
Range. S=small, M=Medium, L=Large, XL= Extra Large
Connectable to VRV
Biddle comfort air curtain
113
BIDDLE AIR
CURTAINS
Recessed (C)
CYVS/M/L-DK-F/C/R
CYVM150DK80FSC
››
››
››
››
››
››
››
››
››
››
CYVM150DK80CSN
CYVM150DK80RSN
Connectable to VRV heat recovery and heat pump
VRV is among the first DX systems suitable
for connection to air curtains
Free-hanging model (F): easy wall mounted installation
Cassette model (C): mounted into a false ceiling
leaving only the decoration panel visible
Recessed model (R): neatly concealed in the ceiling
Provides virtually free air curtain heating via
recovered heat from indoor units in cooling
mode (in case of VRV heat recovery)
Easy and quick to install at reduced costs since no additional
water sytems, boilers and gas connections are required
Maximum energy efficiency stemming from almost
zero down flow turbulence, optimised air flow and the
application of advanced discharge rectifier technology
Around 85% air separation efficiency, greatly reducing
both heat loss and required indoor unit heating capacity
less than
1.5 years
Packtime of
electric air
curtain
12000
total cost
(installation + running cost) in €
PATENTED
TECHNOLOGY
Biddle air curtain for VRV
10000
8000
Daikin heat pump
with Biddle air curtain*
6000
4000
2000
0
1
2
years
* Payback period and gains calculated based upon the following: Air curtain is 9hrs/day – 156 days year (1,404 hrs/year) in use. Annual energy consumption for an electric air curtain: 3,137EUR (COP = 0.95).
Typical installation cost: 1,000EUR; Typical equipment cost: 2,793EUR. Annual energy consumption for CYQS200DK100FBN and ERQ100AV: 748EUR (COP 4.00). Typical installation cost: 2,000EUR; Typical equipment
cost: 5,150EUR. Calculation based upon electricity cost: 0,1705EUR /kWh
114
VRV
Network
Solution
Biddle comfort
air curtain (ca)
Integration in a VRV total solution
Small
CYVS100DK80*BN/*SN
Heating capacity
Power input
Delta T
Casing
Dimensions
Speed 3
Fan only
Heating
Speed 3
Colour
Unit
Nom.
Nom.
Height F/C/R
Width F/C/R
Depth F/C/R
Required ceiling void >
Door height
Max.
Door width
Max.
Weight
Unit
Fan-Air flow rate Heating
Speed 3
Sound pressure level Heating
Speed 3
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD
Required accessories (should be ordered separately)
Power supply
Voltage
kW
kW
kW
K
mm
mm
mm
mm
m
m
kg
m³/h
dBA
mm
V
Medium
CYVS150DK80*BN/*SN CYVS200DK100*BN/*SN CYVS250DK140*BN/*SN CYVM100DK80*BN/*SN CYVM150DK80*BN/*SN CYVM200DK100*BN/*SN CYVM250DK140*BN/*SN
7.40
0.23
0.23
19
9.0
0.35
0.35
11.6
0.46
0.46
16.2
9.2
11.0
13.4
19.9
0.58
0.37
0.56
0.75
0.94
0.58
0.37
0.56
0.75
0.94
15
16
17
14
13
15
BN: RAL9010 / SN: RAL9006
270/270/270
1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548 1,000/1,000/1,048 1,500/1,500/1,548 2,000/2,000/2,048 2,500/2,500/2,548
590/821/561
420
2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3)
1.0
1.5
2.0
2.5
1.0
1.5
2.0
2.5
56
66
83
107
57
73
94
108
1,164
1,746
2,328
2,910
1,605
2,408
3,210
4,013
47
49
50
51
50
51
53
54
R-410A
9.52/16.0
9.52/19.0
9.52/16.0
9.52/19.0
Daikin wired remote control (BRC1E52A/B or BRC1D52)
230
Heating capacity
Power input
Delta T
Casing
Dimensions
Speed 3
Fan only
Heating
Speed 3
Colour
Unit
Nom.
Nom.
Height F/C/R
Width F/C/R
Depth F/C/R
Required ceiling void >
Door height
Max.
Door width
Max.
Weight
Unit
Fan-Air flow rate Heating
Speed 3
Sound pressure level Heating
Speed 3
Refrigerant
Type
Piping connections Liquid/OD/Gas/OD
Required accessories (should be ordered separately)
Power supply
Voltage
kW
kW
kW
K
CYVL150DK200*BN/*SN
CYVL200DK250*BN/*SN
CYVL250DK250*BN/*SN
15.6
0.75
0.75
23.3
1.13
1.13
29.4
1.50
1.50
14
31.1
1.88
1.88
12
15
mm
mm
mm
mm
m
m
kg
m³/h
dBA
3.0 (1) / 2.75 (2) / 2.5 (3)
1.0
76
3,100
53
mm
9.52/16.0
BN: RAL9010 / SN: RAL9006
370/370/370
1,500/1,500/1,548
2,000/2,000/2,048
2,500/2,500/2,548
774/1,105/745
520
3.0 (1) / 2.75 (2) / 2.5 (3)
3.0 (1) / 2.75 (2) / 2.5 (3)
3.0 (1) / 2.75 (2) / 2.5 (3)
1.5
2.0
2.5
100
126
157
4,650
6,200
7,750
54
56
57
R-410A
9.52/19.0
9.52/22.0
Daikin wired remote control (BRC1E52A/B or BRC1D52)
230
1,000/1,000/1,048
V
(1) Favorable conditions: covered shopping mall or revolving door entrance (2) Normal conditions: little direct wind, no opposite open doors, building with ground floor only (3) Unfavorable conditions: location at a corner or
square, multiple floors and/or open stairway
115
BIDDLE AIR
CURTAINS
Large
CYVL100DK125*BN/*SN
Integrated
ventilation
Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels,
stores and other commercial outlets – each one complementary to and as flexible as the
VRV system itself.
Heat Reclaim Ventilation
Proper ventilation is a key component of climate control in buildings, offices and shops.
In its basic function, it ensures a flow of incoming fresh air and outgoing stale air. Our HRV
(heat reclaim ventilation) solution can do much more. It can recover heat and optimise
the balance between indoor and outdoor temperature and humidity, thus
reducing the load on the system and increasing efficiency.
Outdoor air processing in a single unit
Our FXMQ-MF air processing solution uses heat pump technology to combine fresh
air treatment and air conditioning in a single system, thereby eliminating the
usual design problems associated with balancing air supply and discharge. Total system
cost is reduced and design flexibility enhanced because the airconditioning fan coil units
and an outdoor air treatment unit can be connected to the same refrigerant line.
VRV air handling applications
For medium and large commercial spaces, we offer a range of R-410A inverter condensing
units that connect to air handling units. This approach combines the flexibility of our VRV
units with Air Handling Applications, resulting in a simple, reliable design for optimum
control of indoor air quality and maximum efficiency.
For more information consult the Daikin ventilation catalogue or contact your local dealer.
116
Heat reclaim ventilation
Outdoor air processing unit
117
Heat reclaim ventilation
118
Outdoor air processing unit
122
Air handling applications
124
VENTILATION
VRV air handling applications
VAM-FA/FB
Total heat
exchanged
foul air
Heat Reclaim Ventilation
››
Clean outdoor air
››
››
››
››
Foul indoor air
››
››
››
››
Total heat
exchanged
clean air
››
››
››
››
Energy saving ventilation using indoor heating,
cooling and moisture recovery
Ideal solution for shops, restaurants or offices requiring
maximum floor space for furniture, decorations and fittings
Free cooling possible when outdoor temperature is
below indoor temperature (eg. during nighttime)
Low energy consumption thanks to DC inverter fans
Prevent energy losses from over-ventilation while
maintaining indoor air quality with optional CO2 sensor
Can be used as stand alone unit or integrated in the VRV system
Wide range of units: air flow rate from 150 up to 2,000 m³/h
High efficiency filters available in F6 ,F7, F8 grades
Shorter installation time thanks to easy adjustment
of nominal air flow rate, so less need for dampers
compared with traditional installations
Specially developed heat exchange element
with High Efficiency Paper (HEP)
No drain piping needed
Can operate in over- and under pressure
Total solution for fresh air with Daikin supply
of both VAM and electrical heater
High efficiencies filters available
in F6, F7, F8 grades
Prevent energy losses from over ventilation with CO2 sensor
Enough fresh air is needed to create an enjoyable environment, but ventilating constantly is leading to energy waste. Therefore an optional CO2
sensor can be installed which switches off the ventilation system when there is enough fresh air in the room, thus saving energy.
CO2 level
Example of CO2 sensor operation in a meeting room:
9 AM
12 PM
Fixed ventilation rate
Ventilation amount
5 PM
Decrease in air volume and
more energy saving compared
to fixed ventilation rate
Increase in air
volume and
better comfort
compared to fixed
ventilation rate
7
8
9
10
Morning meeting
When many people are in the room,
more fresh air is brought in to maintain
comfortable CO2 levels. When fewer
people are in the room, energy is saved
by bringing in less fresh air.
11
12
13
14
Lunch time
15
16
17
18
19
hour
Meeting
Using CO2 sensors has the most energy-saving potential in buildings where occupancy fluctuates during a 24-hour period, is unpredictable and peaks
at a high level. For example office buildings, government facilities, retail stores and shopping malls, movie theaters, auditoriums, schools, entertainment
clubs and nightclubs. The ventilation unit's reaction to fluctuations in CO2 can be easily adjusted by the customer.
118
Heat recovery ventilation
High Efficiency Paper
OUTDOOR
Operation of the high
effiency paper.
INDOOR
30.6°C
62% RH
Cross flow of air to
exchange heat and
moisture.
32°C
70% RH
SA
27.4°C
63% RH
RA
26°C
50% RH
Integrally-formed liner
Temperature
and humidity is
exhanged between
the layers
SA
Integrallyformed liner
RA
RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room)
Heat exchange mode Nom.
Ultra high
Ultra high
Bypass mode
Nom.
Temperature exchange efficiency - 50Hz Ultra high
Ultra high
Enthalpy exchange Cooling
efficiency - 50Hz Heating
Ultra high
Operation mode
Heat exchange system
Heat exchange element
Dimensions
Unit
HeightxWidthxDepth
Weight
Unit
Fan-Air flow rate Heat exchange mode Ultra high
- 50Hz
Bypass mode
Ultra high
Fan-External static pressure - 50Hz Ultra high
Heat exchange mode Ultra high
Sound pressure
level - 50Hz
Bypass mode
Ultra high
Min.
Operation range Max.
Relative humidity
Connection duct diameter
Power supply
Phase/Frequency/Voltage
Current
Maximum fuse amps (MFA)
kW
kW
%
%
%
mm
kg
m³/h
m³/h
Pa
dBA
dBA
°CDB
°CDB
%
mm
Hz/V
A
VAM150FA
0.116
0.116
74
VAM250FA
0.141
0.141
72
VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB
0.132
0.178
0.196
0.373
0.375
0.828
0.852
0.132
0.178
0.196
0.373
0.375
0.828
0.852
75
74
75
58
61
58
60
61
64
65
62
63
65
66
Heat exchange mode / Bypass mode / Fresh-up mode
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
285x776x525
301x828x816
364x1,004x868
364x1,004x1,156 726x1,512x868 726x1,512x1,156
24
33
52
55
64
131
152
150
250
350
500
650
800
1,000
1,500
2,000
150
250
350
500
650
800
1,000
1,500
2,000
69
64
98
93
137
157
137
27 / 28.5
28 / 29
32
33
34.5
36
39.5
40
27 / 28.5
28 / 29
32
33.5
34.5
36
40.5
40
-15
50
80% or less
100
150
200
250
350
1~/50/60/220-240/220
15
16
Total solution for fresh air with Daikin supply of both VAM and electrical heaters
Increased comfort in low outdoor temperature thanks to the heated outdoor air
Integrated electrical heater concept (no additional accessories required)
Standard dual flow and temperature sensor
Flexible setting with adjustable setpoint
Increased safety with 2 cut-outs: manual & automatic
BMS integration thanks to:
• Volt free relay for error indication
• 0-10VDC input for setpoint control
›› Capacities ranging from 1 to 2.5 kW
VENTILATION
VENTILATION
Power input - 50Hz
››
››
››
››
››
››
119
VH electrical heater
VKM-GM / VKM-G
Heat Reclaim Ventilation,
humidification and air processing
››
››
››
››
››
››
››
››
››
››
Energy saving ventilation using indoor heating, cooling and
moisture recovery
Creates a high quality indoor environment by pre conditioning
incoming fresh air
Humidification of the incoming air results in comfortable
indoor humidity level, even during heating
Ideal solution for shops, restaurants or offices requiring
maximum floor space for furniture, decorations and fittings
Free cooling possible when outdoor temperature is below
indoor temperature (eg. during nighttime)
Low energy consumption thanks to DC fan motor
Prevent energy losses from over-ventilation while maintaining
indoor air quality with optional CO2 sensor
Shorter installation time thanks to easy adjustment of nominal
air flow rate, so less need for dampers compared with
traditional installation.
Specially developed heat exchange element with
High Efficiency Paper (HEP)
Can operate in over- and under pressure
Operation example: humidification & air processing (heating mode)1
Exhaust Fan
EA
(Exhaust air to outdours)
Heat Exchanger
Elements
Damper Motor
Damper
DX coil
(Direct expansion coil)
OA
(Fresh air from outdoors)
RA
(Return air from room)
Air Supply Fan
SA (Supply air to room)
Electronics Box (Control box)
Float switch
Humidifier element:
Utilizing the principle of capillary action, water is
permeated throughout the humidifier element. The
heated air from the DX coil passes through the humidifier
and absorbs the moisture.
water
AIRFLOW
Drain pan
1
Solenoid
valve
VKM-GM example
120
Drain
SA
VKM-GM example
Heat recovery ventilation,
humidification & air processing
Heat reclaim ventilation, air processing and humidication
kW
kW
kW
kW
%
%
%
mm
kg
m³/h
m³/h
Pa
dBA
dBA
°CDB
°CDB
°CDB
°CDB
°CDB
mm
mm
mm
mm
Hz/V
A
Heat reclaim ventilation and air processing
VKM50GBM
0.270
0.270
4.71 / 1.91 / 3.5
5.58 / 2.38 / 3.5
76/76/77.5
64/64/67
67/67/69
VKM80GBM
VKM100GBM
VKM50GB
VKM80GB
VKM100GB
0.330
0.410
0.270
0.330
0.410
0.330
0.410
0.270
0.330
0.410
7.46 / 2.96 / 5.6
9.12 / 3.52 / 7.0
4.71 / 1.91 / 3.5
7.46 / 2.96 / 5.6
9.12 / 3.52 / 7.0
8.79 / 3.79 / 5.6
10.69 / 4.39 / 7.0
5.58 / 2.38 / 3.5
8.79 / 3.79 / 5.6
10.69 / 4.39 / 7.0
78/78/79
74/74/76.5
76/76/77.5
78/78/79
74/74/76.5
66/66/68
62/62/66
64/64/67
66/66/68
62/62/66
71/71/73
65/65/69
67/67/69
71/71/73
65/65/69
Heat exchange mode / Bypass mode / Fresh-up mode
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
Natural evaporating type
Galvanised steel plate
387x1,764x832
387x1,764x1,214
387x1,764x832
387x1,764x1,214
100
119
123
94
110
112
500
750
950
500
750
950
500
750
950
500
750
950
200
205
110
210
150
38
40
39
41.5
41
39
41
40
41.5
41
0°C~40°CDB, 80% RH or less
-15°C~40°CDB, 80% RH or less
0°C~40°CDB, 80% RH or less
-15
43
R-410A
200
250
200
250
6.35
12.7
6.4
PT3/4 external thread
Multidirectional fibrous fleeces
1~/50/220-240
15
121
VENTILATION
VENTILATION
Ultra high
Power input - 50Hz Heat exchange mode Nom.
Ultra high
Bypass mode
Nom.
Fresh air
Cooling
conditioning load Heating
Temperature exchange efficiency - 50Hz Ultra high/High/Low
Ultra high/High/Low
Enthalpy exchange Cooling
efficiency - 50Hz Heating
Ultra high/High/Low
Operation mode
Heat exchange system
Heat exchange element
Humidifier
System
Casing
Material
HeightxWidthxDepth
Dimensions
Unit
Weight
Unit
Fan-Air flow rate Heat exchange mode Ultra high
- 50Hz
Bypass mode
Ultra high
Fan-External static pressure - 50Hz Ultra high
Heat exchange mode Ultra high
Sound pressure
level - 50Hz
Bypass mode
Ultra high
Operation range Around unit
Supply air
Return air
On coil
Cooling Max.
temperature
Heating Min.
Refrigerant
Type
Connection duct diameter
Piping
Liquid
OD
connections
Gas
OD
Water supply
Drain
Air filter
Type
Power supply
Phase/Frequency/Voltage
Current
Maximum fuse amps (MFA)
FXMQ-MF
Outdoor Air Processing Unit,
ventilation and air processing
Combined fresh air treatment
and air conditioning via a single system
››
››
››
››
››
1
100% fresh air intake possible
Leaves maximum floor and wall space for
furniture, decorations and fittings
Operation range: -5°C to 43°C
225 Pa external static pressure allows extensive ductwork
runs and flexible application: ideal for use in large areas
Drain pump kit available as accessory
Not connectable to VRVIII-S (RXYSQ-P8V1, RXYSQ-PBY1)
122
Ventilation and air processing
in one system
Piping
connections
Power supply
Nominal
Nominal
HeightxWidthxDepth
Nominal
Nominal (220V)
Cooling max.
Heating min.
OD
OD
Liquid
Gas
Drain
Phase / Frequency / Voltage
kW
kW
kW
kW
mm
kg
m3/min
m3/min
Pa
dBA
dBA
°CDB
°CDB
mm
mm
FXMQ125MF
14.0
8.9
0.359
0.359
470x744x1,100
86
18
185
FXMQ200MF
22.4
13.9
0.548
0.548
FXMQ250MF
28.0
17.4
0.638
0.638
470x1,380x1,100
123
28
225
R-410A
-
42
35
205
47
43
-5
9.52
19.1
PS1B
1~ / 50 / 220-240
15.9
Hz / V
123
22.2
VENTILATION
VENTILATION & AIR PROCESSING
Cooling capacity Nom.
Heating capacity Nom.
Power Input
Cooling
(50Hz)
Heating
Dimensions
Unit
Weight
Unit
Air Flow Rate
Cooling
Heating
External Static Pressure Standard
Refrigerant
Type
Sound Power
Cooling
Sound Pressure
Cooling
Operation range On coil
temperature
Daikin Air handling unit
Wide range of air flows
In situations where the Daikin commercial range of ventilation units cannot satisfy the ventilation requirement due to building constraints (large
atriums, banquet halls, etc) air handling units represent the ideal solution. Daikin’s wide range of air handling systems handle air flow rates from
500 m³/h up to 140,000 m³/h. The air handler unit can be adapted to deliver whatever air flow you require, via the specific dimensions of flow
section available at the installation.
Air flow (m3/h * 1000)
0
15
30
45
60
75
90
105
120
135
The most flexible solution
D-AHU Professional
Daikin AHU Range
1,100 m3/h
D-AHU Energy
up to 140,000 m3/h
Best seasonal performance and
return on investment
1,500 m3/h
up to 70,000 m3/h
Ideal to cover your basic AHU needs
D-AHU Easy
500 m3/h
up to 30,000 m3/h
Daikin fresh air package - plug & play
The D-AHU Professional and Energy series provide a complete solution including unit control (EKEXV, EKEQ, DDC controller) factory
mounted and configured, plug & play with our ERQ and VRV condensing units.
The easiest solution as you save time and only have one point of contact!
Return on investment
The air handling unit (AHU) is critical to an effective climate control system and, although the initial investment can appear high, the savings
generated by our advanced designs and operating efficiencies guarantee a rapid return on the investment made. Our AHU Energy series has
been designed to deliver exceptional performance thus driving down the energy consumed and so lowering energy bills. Taken over the
expected 15-year life-span of the equipment, this will result in a substantial saving, especially in a time of ever increasing energy prices.
124
Pre-defined sizes
VENTILATION
27 fixed sizes are available, optimized to reach the best compromise between competitiveness and manufacturing standardisation. However,
Daikin’s section by section design means that units can be sized by 1cm increments and assembled on site, without welding, to suit the space
constraints of the installation.
High efficiency components
All Daikin air handlers have been designed for optimum energy efficiency. Polyurethane or Mineral wool panels guarantee excellent thermal
insulation performance. Filters are provided with a large choice of efficiency filtration class.
125
Air handling unit applications
Why use ERQ and VRV condensing units for
connection to air handling units?
High Efficiency
Daikin heat pumps are renowned for their high energy efficiency with COPs up to 4.56 in heating1. The VRV range offers both heat pump and
heat recovery units with part load efficiencies as high as 9.02. Integrating the AHU with a heat recovery system is highly effective since an office
system can frequently be in cooling mode while the outdoor air is too cold to be brought inside in an unconditioned state. In this case heat
from the offices is merely transferred to heat up the cold incoming fresh air. In the absence of an AHU this ‘free heating’ the incoming fresh air
would not be possible.
1 ERQ100AV1 heat pump
2 REYQ8P8 50% cooling - 50% heating load. Conditions: outdoor temperature 11°CDB, indoor temperature 18°CWB, 22°CDB
Fresh air supplied at 21°C. The temperature
difference with the outdoor air is heated up for free
by heat recovery via A/C system
Outside air = 10°C
Indoor temperature 22°C, needs cooling
because of solar radiation. The excessive heat
can be transferred to the AHU.
High comfort levels
Daikin ERQ and VRV units respond rapidly to fluctuations in supply air temperature, resulting in a steady indoor temperature and resultant high
comfort levels for the end user. Daikin ERQ and VRV units respond rapidly to fluctuations in the supply air temperature, resulting in a steady
indoor temperature, together with the dehumidification this results in high comfort levels for the end user. The ultimate is the VRV range which
improves comfort even more by offering continuous heating, also during defrost.
Easy Design and Installation
The system is easy to design and install since no additional water systems such as boilers, tanks and gas connections etc. are required. This also
reduces the total system cost.
126
Flexible control possibilities for air handling units
In order to maximize installation flexibility,
3 types of control systems are offered
Control x: Control of air temperature
(discharge temperature, suction temperature, room temperature) via external device (DDC controller)
Control y: Control of evaporating temperature via Daikin control (no DDC controller needed)
Control z: Control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed)
Possibility X (Td/Tr control):
Air temperature control via DDC controller
Ts
Room temperature is controlled as a function of the air handling unit suction
or discharge air (customer selection). The DDC controller is translating
the temperature difference between set point and air suction temperature (or
air discharge temperature or room temperature) into a reference voltage (0-10V)
which is transferred to the Daikin control box (EKEQFCBA). This reference voltage
will be used as the main input value for the compressor frequency control.
Te
Daikin
control box:
EKEQFCB
DDC
Td
AHU
Tr
Room
Possibility Y (Te/Tc control):
By fixed evaporating temperature
A fixed target evaporating temperature of between 3°C and 8°C can be set by the
customer. In this case, room temperature is only indirectly controlled. The cooling
load is determined from the actual evaporating temperature (i.e. load to the heat
exchanger). A Daikin infrared remote control (BRC1D52 or BRC1E52A/B - optional)
can be connected for error indication.
Daikin
control box:
EKEQFCB
KRP4A51
Ts
Daikin
control box:
EKEQDCB
EKEQMCB
Set point can be fixed via standard Daikin infrared remote control. Remote ON/
OFF can be achieved by an optional adapter KRP4A51.
No external DDC controller should be connected. The cooling load is determined
from the air suction temperature and set point on the Daikin controller.
EKEQFCB
Possibility z
FEATURES
DDC controller is required
Temperature control using air suction or air discharge temperature
Using Daikin infrared remote control BRC1D52 or BRC1E52A/B
Temperature control using air suction temperature
* EKEQMCB (for ’multi’ application)
127
Td
Tr
Room
VENTILATION
= Air suction temperature
= Air discharge temperature
= Room temperature
= Evaporating temperature
= Air Handling Unit
= Digital Display Controller
Using fixed evaporating temperature, no set point can be set using remote control
EKEQDCB
EKFQMCB*
Te
AHU
BRC1D52
BRC1E52A/B
Ts
Td
Tr
Te
AHU
DDC
Possibility y
Td
Room
ON / OFF
Using Daikin infrared remote control
(BRC1D52 or BRC1E52A/B - optional)
Possibility x
Tr
BRC1D52
BRC1E52A/B
Possibility Z (Ts/Tr control):
OPTION KIT
AHU
Te
Ts
VRV
Air handling application (pair & multi)
A R-410A inverter condensing units range
for multi application with air handling units
››
››
››
››
››
››
››
››
Inverter controlled units
Large capacity range (from 8 to 54HP)
Heat recovery, heat pump
R-410A
Control of room temperature via Daikin control
Large range of expansion valve kits available
BRC1E52A/B is used to set the set point temperature (connected to the EKEQMCB).
Connectable to all VRV heat recovery and heat pump systems
Different control possibilities
VRV IV heat pump
Control possibilities
VRV heat
recovery
VRV III-S
VRV III-C
VRV IV W-series
R*YQ8-10T
R*YQ12-30T
4 x R*YQ8T
4 x R*YQ10T
R*YQ52-54T
REYQ-T
REYHQ-P8/P9
REYHQ-P
REYAQ-P
RXYSQ-PAV
RXYSQ-PAY
RTSYQ-PA
RWEYQ-T
X
P
P1
P2
-
-
-
-
-
Y
P
P1
P2
-
-
-
-
-
Z
M
M
M
M
M
M
M
M
P = pair
M = multi
1 By use of split coil (interlaced)
2 Separate coil per outdoor unit
128
X,Y control for VRV IV
R*YQ8-10T
4 x R*YQ8T
4 x R*YQ10T
R*YQ12-30T
VENTILATION
Z control for all VRV outdoor units
Refrigerant piping
F1-F2
other communication
129
ERQ
Air handling application (pair)
A range of R-410A inverter condensing units
for pair application with air handling units
››
››
››
››
››
››
Inverter controlled units
Large capacity range (from 100 to 250 class)
Heat pump
R-410A
Wide range of expansion valve kits available
Up to 4 ERQ units can be connected to an
interlaced coil in one air handling unit
F1 - F2
Refrigerant piping
The “Daikin Fresh Air Package” provides a complete Plug & Play
Solution including AHU, ERQ or VRV Condensing Unit and all
unit control (EKEQ, EKEX, DDC controller) factory mounted and
configured. The easiest solution with only one point of contact.
VENTILATION
Capacity range
Cooling capacity
Heating capacity
Power input
Nom.
Nom.
Cooling
Heating
EER
COP
Dimensions
Weight
Fan-Air flow rate
Power supply
Current
VENTILATION
Capacity range
Cooling capacity
Heating capacity
Power input
EER
COP
Dimensions
Weight
Fan-Air flow rate
Power supply
Current
ERQ125AV1
5
14.0
16.0
3.51
3.86
ERQ140AV1
6
15.5
18.0
4.53
4.57
3.42
3.94
3.99
HeightxWidthxDepth
Nom.
Nom.
Nom.
Nom.
Nom.
Min./Max.
Min./Max.
Heating Min.
Cooling Max.
mm
kg
m³/min
m³/min
dBA
dBA
dBA
°CDB
°CWB
°CDB
°CDB
Type
Liquid
OD
Gas
OD
Drain
OD
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
mm
mm
mm
Hz/V
A
Nom.
Nom.
Cooling
Heating
HP
kW
kW
kW
kW
Unit
Unit
Cooling
Heating
Sound power level Nom.
Sound pressure level Nom.
Operation range Cooling
Heating
On coil
temperature
Refrigerant
Piping
connections
ERQ100AV1
4
11.2
12.5
2.81
2.74
4.56
Unit
Unit
Cooling
Heating
Sound power level Cooling
Sound pressure
Cooling
level
Heating
Operation range Cooling
Heating
On coil
temperature
Refrigerant
Piping
connections
Nom.
Nom.
HP
kW
kW
kW
kW
Nom.
Nom.
HeightxWidthxDepth
Nom.
Nom.
Min./Max.
Min./Max.
Heating Min.
Cooling Max.
Type
Liquid
OD
Gas
OD
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
mm
kg
m³/min
m³/min
dBA
dBA
°CDB
°CWB
°CDB
°CDB
mm
mm
Hz/V
A
4.15
1,345x900x320
120
106
102
66
50
52
105
67
51
53
-5/46
-20/15.5
10
35
R-410A
9.52
69
53
55
15.9
19.1
26x3
1N~/50/220-240
32.0
ERQ125AW1
5
14.0
16.0
3.52
4.00
3.98
4.00
1,680x635x765
159
95
95
72
54
15.9
16
ERQ200AW1
8
22.4
25.0
5.22
5.56
4.29
4.50
ERQ250AW1
10
28.0
31.5
7.42
7.70
3.77
4.09
1,680x930x765
187
171
171
240
185
185
78
57
-5/43
-20/15
10
35
R-410A
9.52
19.1
3N~/50/400
58
22.2
25
130
Overview of expansion valves and control boxes
Daikin also offers a range of expansion valve kits and control
boxes to connect ERQ and VRV condensing units to third
party
air handling units
VRV combination table
EKEXV CLASS
ALLOWED HEAT EXCHANGER CAPACITY (KW)
COOLING (EVAPORATION TEMPERATURE 6°C)
HEATING (CONDENSING TEMPERATURE 46°C)
MINIMUM
STANDARD
MAXIMUM
MINIMUM
STANDARD
MAXIMUM
5.0
5.6
6.2
5.6
6.3
7.0
6.3
7.1
7.8
7.1
8.0
8.8
7.9
9.0
9.9
8.9
10.0
11.1
10.0
11.2
12.3
11.2
12.5
13.8
12.4
14.0
15.4
13.9
16.0
17.3
50
63
80
100
125
140
200
250
15.5
17.7
24.7
16.0
22.4
28.0
17.6
24.6
30.8
17.4
19.9
27.8
18.0
25.0
31.5
19.8
27.7
34.7
ERQ combination table
OUTDOOR UNIT
1~
3~
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
CLASS 63
EKEXV63
P
P
P
-
CLASS 80
EKEXV80
P
P
P
P
-
CLASS 100
EKEXV100
P
P
P
P
P
EXPANSION VALVE KIT
CLASS 125
EKEXV125
P
P
P
P
P
CLASS 140
EKEXV140
P
P
P
P
CLASS 200
EKEXV200
P
CLASS 250
EKEXV250
P
ERQ250AW1
-
-
-
P
P
P
P
P: Pair: Combination depending on air handling units coils volume.
EKEXV - Expansion valve kit for air handling applications
VENTILATION
Dimensions
Weight
Sound pressure level
Operation range
Refrigerant
Piping
connections
EKEXV50
Unit
Unit
Nom.
On coil
temperature
Type
Liquid
Gas
HeightxWidthxDepth
Heating Min.
Cooling Max.
mm
kg
dBA
°CDB
°CDB
OD
OD
mm
mm
EKEXV63
EKEXV80
6.35
6.35
EKEXV100
EKEXV125
401x215x78
2.9
45
10 (1)
35 (2)
R-410A
9.52
9.52
EKEXV140
EKEXV200
EKEXV250
VENTILATION
(1) The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information. (2) 45% Relative humidity.
EKEQ - Control box for air handling applications
VENTILATION
Application
Outdoor unit
Dimensions
Weight
Power supply
EKEQFCB
EKEQDCB
EKEQMCB
Multi
VRV
Pair
ERQ
Unit
HeightxWidthxDepth
Unit
Phase/Frequency/Voltage
mm
kg
Hz/V
132x400x200
3.9
3.6
1~/50/230
131
User friendly
control
systems
An air conditioning system will only operate as efficiently as its control system allows and
the importance of precise, user friendly equipment is as relevant to simple residential
room temperature controls as it is to full remote monitoring and regulation of large scale
commercial buildings.
In buildings with multiple air conditioning units that operate for long hours, system
efficiency plays a paramount role in the pursuit of reduced energy consumption. Maximum
efficiency demands that maximum control of all aspects of system operation must be
in harmony with important allied considerations such as round the clock monitoring,
preventive maintenance, fault predictive analysis and rapid response in the event of
malfunctions..
Daikin manufactures and markets an extensive portfolio of state of the art computerised
control systems that offer building owners, landlords and tenants comprehensive system
cover backed up by vital data on operational performance and running costs on air
conditioning systems of any size and complexity.
132
Control systems
Individual control systems
Wired / infrared remote control
134
134
Remote monitoring and maintenance
146
ACNSS
(Air Conditioning Network Service System) 146
Centralised control systems
136
Centralised remote control / Unified ON/OFF
control / Schedule timer
136
137
137
Mini BMS
138
138
148
Wireless room temperature sensor
Wired room temperature sensor
Other integration devices
149
149
150
CONTROL
SYSTEMS
Communication interfaces
140
Modbus interface
140
KNX Interface
142
144
145
Daikin configurator software
133
BRC1E52A/B
User friendly remote control with contemporary design
Save energy
A series of energy saving functions
that can be individually selected
››
››
››
››
››
››
Temperature range limit
Setback function
Presence & floor sensor connection
(available on new round flow cassette)
kWh indication
Set temperature auto reset
Off timer
Temperature range limit avoids
excessive heating or cooling
Save energy by constraining the lower temperature limit in cooling
and upper temperature limit in heating mode.
note : Also available in auto cooling/heating change over mode.
kWh indication keeps
track of your consumption
The kWh indication shows an indicative electricity consumption of
the last day/month/year.
Other functions
››
››
››
››
››
››
››
Up to 3 independent schedules can be set, so the user can easily change
the schedule himself throughout the year (e.g. Summer, winter, mid-season)
Possibility to individually restrict menu functions
Easy to use: all main functions directly accessible
Easy setup: clear graphical user interface for advanced menu settings
Real time clock with auto update to daylight saving time
Built-in backup power: when a power failure occurs all settings remain stored
up to 48 hours
Supports multiple languages
-- English, German, Dutch, Spanish, Italian, Portuguese, French, Greek, Russian,
Turkish, Polish (BRC1E52A)
-- English, German, Czech, Croatian, Hungarian, Romanian, Slovenian,
Bulgarian, Slovak, Serbian, Albanian (BRC1E52B)
Graphical display of indicative
electricity consumption
134
ARC*/BRC*
BRC1D52
Individual control systems
BRC944B2
ARC466A1
BRC4*/BRC7*
BRC944B2*/BRC1D52
Wired remote control
Display
››
››
››
››
››
››
››
››
››
››
››
››
››
››
››
››
››
››
››
Schedule timer:
• Five day actions can be set as follows:
-- set point: unit is switched ON and normal operation is maintained
-- OFF: unit is switched OFF1
-- limits: unit is switched ON and min./max. control
(cf. limit operation for more details)
Home leave (frost protection): during absence, the indoor temperature
can be maintained at a certain level.
This function can also switch the unit ON/OFF
User friendly HRV function, thanks to the introduction
of a button for ventilation mode and fan speed
Constantly monitoring of the system for
malfunctions in a total of 80 components
Immediate display of fault location and condition
Reduction of maintenance time and costs
Operating mode1
Heat Recovery Ventilation (HRV) in operation
Cool / heat changeover control
Centralised control indication
Group control indication
Set temperature1
Air flow direction1
Programmed time
Inspection test / operation
Fan speed1
Clean air filter
Defrost / hot start
Malfunction
1
Only functions marked with ‘1’ are available on BRC944B2
ARC4*/BRC4*/BRC7*
Infrared remote control
Operation buttons: ON / OFF, timer mode start / stop, timer mode on / off,
programme time, temperature setting, air flow direction (1), operating
mode, fan speed control, filter sign reset (2), inspection (2)/ test indication (2) Display: Operating mode, battery change, set temperature, air flow
direction (1), programmed time, fan speed, inspection / test operation (2)
1.
2.
3.
Not applicable for FXDQ, FXSQ, FXNQ, FBDQ, FDXS, FBQ
For FX** units only
For all features of the remote control, refer to the operation manual
NEW BRC2E52A / BRC3E52A
››
››
››
››
››
››
››
››
Symbol driven interface for intuitive control
Functions restricted to basic customer needs
Contemporary design
Energy saving thanks to set point limitation
Flat backpanel for easy installation
2 versions available:
• Heat pump type: temperature, fan speed, ON/OFF
• Heat recovery type: temperature, mode, fan speed, ON/OFF
Replaces existing BRC2C51 & BRC3A61
Available spring 2014
135
CONTROL
SYSTEMS
Simplified wired remote control developed
for hotel applications
Centralised control systems
DCS302C51
DCS301B51
DST301B51
Centralised control of the Sky Air and VRV system can be achieved via
3 user friendly compact controls: centralised remote control, unified
on/off control and schedule timer. These controls may be used
independently or in combination where 1 group = several (up to 16)
indoor units in combination and 1 zone = several groups in combination.
A centralised remote control is ideal for use in tenanted commercial
buildings subject to random occupation, enabling indoor units to be
classified in groups per tenant (zoning).
The schedule timer programmes the schedule and operation conditions
for each tenant and the control can easily be reset according to varying
requirements.
DCS302C51
DCS301B51
DST301B51
Providing individual control of 64 groups
(zones) of indoor units.
Providing simultaneous and individual
control of 16 groups of indoor units.
Enabling 64 groups to be programmed.
• a maximum of 64 groups (128 indoor
units, max. 10 outdoor units) can be
controlled
• a maximum of 128 groups (128 indoor
units, max. 10 outdoor units) can be
controlled via 2 centralised remote
controls in separate locations
• zone control
• group control
• malfunction code display
• maximum wiring length of 1,000m (total:
2,000m)
• air flow direction and air flow rate of HRV
can be controlled
• expanded timer function
• a maximum of 16 groups (128 indoor
units) can be controlled
• 2 remote controls in separate locations
can be used
• operating status indication (normal
operation, alarm)
• centralised control indication
• maximum wiring length of 1,000m (total:
2,000m)
• a maximum of 128 indoor units can be
controlled
• 8 types of weekly schedule
• a maximum of 48 hours back up power
supply
• a maximum wiring length of 1,000m (total:
2,000m)
Centralised remote control
Unified ON/OFF control
136
Schedule timer
DTA113B51
Basic solution for control of Sky Air and VRV
››
››
DS-NET adapter
DTA113B51
Rotation function
Backup operation function.
BRC1D52
Up to 4 units / 1 adapter
DCS601C51
Detailed & easy monitoring and operation of VRV systems
(max. 64 indoor units groups).
Public line
third party controller (domotics, BMS, etc.)
Fire alarm
Onboard
modem
Ethernet
Forced OFF contact input
Air conditioning Network
Service System
DIII-NET
Indoor units
HRV
DCS601C51
Languages
Control
Monitoring
Open interface
››
››
››
››
››
››
››
››
››
››
System layout
››
››
Up to 64 indoor units
can be controlled
Touch panel (full colour
LCD via icon display)
Management
››
››
Easy management of
electricity consumption
Enhanced history function
››
››
››
››
››
››
››
››
››
››
››
››
››
Individual control
(set point, start/stop,
fan speed) (max. 64
groups/indoor units)
Set back shedule
Enhanced scheduling function
(8 schedules, 17 patterns)
Flexible grouping in zones
Yearly schedule
Fire emergency stop control
Interlocking control
Increased HRV monitoring
and control function
Automatic cooling /
heating change-over
Heating optimization
Temperature limit
Password security:
3 levels (general,
administration & service)
Quick selection and full control
Simple navigation
››
››
››
››
Visualisation via Graphical
User Interface (GUI)
Icon colour display
change function
Indoor units operation mode
Indication filter replacement
Multi PC
Cost performance
››
››
››
››
››
137
Free cooling function
Labour saving
Easy installation
Compact design: limited
installation space
Overall energy saving
Communication to any third
party controller (domotics,
BMS, etc.) is possible via open
interface (http option)
Connectable to
››
››
››
››
VRV
HRV
Sky Air
Split (via interface adapter)
CONTROL
SYSTEMS
English
French
German
Italian
Spanish
Dutch
Portuguese
New
Management control
99 Cost competitive mini BMS
99 Cross-pillar integration
of Daikin products
99 Integration of third party
equipment
Full integration across
all product pillars
System overview
iTM Integrator
(DCM601A53)
Up to 2,560
groups
HUB
A maximum of 5 intelligent Touch Managers can be connected to a single iTM Integrator.
Integration of third
party equipment
Di/Pi line
Max. 200m
Fire alarm
Full control
of Daikin
HVAC-R
portfolio
internet
intranet
LAN
Web
Access
3G
iTM plus adaptor line
Max. 7 adapters
DCM601A51
DCM601A52
Di/Pi port
kWh meter
Direct plug & play connection!
Lighting
Pump
Chillers
and AHU
Split
indoor
units, air
curtain
I/O module
WAGO
interface
indoor
units,
air curtain,
hydrobox
Fan Refrigeration
coil
units
I/O module
BACnet
protocol
Fan
138
W
NE
NE
Sensor
W
I/O module
NE
W
USB memory
DCM601A51
User friendliness ››
››
››
Intuitive user interface
Visual lay out view and direct access to indoor unit main funtions
All functions direct accessible via touch screen or via web interface
Smart energy management
››
››
››
››
Monitoring if energy use is according to plan
Helps to detect origins of energy waste
Powerful schedules guarantee correct operation
throughout the year
Save energy by interlocking A/C operation with other equiment
such as heating
Flexibility ››
››
››
››
BACnet protocol for 3rd party products integration
I/O for integration of equipment such as lights, pumps…
on WAGO modules
Modular concept for small to large applications
Control up to 2,560 indoor unit groups
Flexibility in size
64 up to 2,560
groups
Easy servicing and
commissioning
Remote refrigerant containment check preventing on site visit
Simplified troubleshooting
Save time on commissioning thanks to the pre-commissioning tool
Auto registration of indoor units
Functions
overview
System layout
WAGO Interface
››
››
››
Up to 2,560 unit groups can be controlled
(ITM plus Integrator + 7 iPU (incl. iTM adaptor)
Ethernet TCPIP
Management
››
››
››
››
DCM601A51
Languages
››
››
››
››
››
››
››
English
French
German
Italian
Spanish
Dutch
Portuguese
››
››
Web access
Power Proportional Distribution (option)
Operational history (malfunctions,
operation hours, …)
Smart energy management
- monitor if energy use is according to plan
- detect origins of energy waste
Setback function
Sliding temperature
Control
››
››
››
››
››
Individual control (2,560 groups)
Schedule setting (Weekly schedule,
yearly calender, seasonal schedule)
Interlock control
Setpoint limitation
Temperature limit
139
Modular integration
of 3rd party equipment
- WAGO coupler
(interface between WAGO and Modbus)
- Di module
- Do module
- Ai module
- Thermistor module
Connectable to
››
››
››
››
››
››
››
››
››
DX Split, Sky Air, VRV
Chillers (with Microtech controller)
Daikin AHU
Fan coils
Daikin Altherma Flex type
LT and HT hydroboxes
Air curtains
WAGO I/O
BACnet protocol
CONTROL
SYSTEMS
››
››
››
››
RTD
Modbus Interface
Integration of
RA, Sky Air, VRV,
Daikin Altherma Flex
and AHU in BMS or
home automation
systems
RTD-RA
RTD-20
››
››
››
››
Modbus interface for monitoring and control of residential indoor
units
RTD-NET
››
››
Modbus interface for monitoring and control of Sky Air, VRV, VAM
and VKM
Advanced control of Sky Air, VRV, VAM/VKM and air curtains
Clone or independent zone control
Increased comfort with integration of CO2 sensor for fresh air volume
control
Save on runningcosts via
- pre/post and trade mode
- set point limitation
- overall shut down
- PIR sensor for adaptive deadband
RTD-10
RTD-HO
››
››
››
Advanced integration into BMS of Sky Air, VRV, VAM and VKM
through either:
-- Modbus
-- Voltage (0-10V)
-- Resistance
Duty/standby function for server rooms
››
››
RTD-W
››
RTD-LT
››
››
Modbus interface for monitoring and control of Sky Air, VRV, VAM
and VKM
Intelligent hotel room controller
Modbus interface for monitoring and control of Daikin Altherma
low temperature (EHVH(X)-C / EHBH(X)-C)
Voltage and resistance control
Photovoltaic operation signal for energy saving
140
Modbus interface for monitoring and control of Daikin Altherma Flex
Type, VRV HT hydrobox and small inverter chiller
Overview functions
MAIN FUNCTIONS
Dimensions
HxWxD
mm
On/off prohibition
Key card + window contact
Set back function
Prohibit or restrict remote control functions (setpoint limitation, ...)
Modbus (RS485)
Dry contact control
Group control
0 - 10 V control
Resistance control
IT application
Heating interlock
Output signal (on/defrost, error)
Space heating / cooling operation
Domestic hot water control
Retail application
Partitioned room control
Air curtain
Smart grid control
RTD-RA
80 x 80 x 37,5
RTD-NET
RTD-10
RTD-20
RTD-HO
100 x100 x 22









(1)











***
***


**

****




RTD-W
RTD-LT/CA
















(1): By combining RTD-RA devices
RTD-RA
M
M
RTD-NET
M
M
RTD-10
M,V,R
M,V,R
RTD-20
M
M
RTD-HO
M*
M*
M
M
M
M
M
M
M
M
M,V,R
M,V,R
M,V,R
M,V,R
M,V,R
M
M
M
M
M
M*
M*
M*
M
M
MONITORING FUNCTIONS
RTD-RA
On/Off
M
Room temperature setpoint
M
Set point leaving water temperature (heating/cooling)
Operation mode
M
Domestic Hot Water reheat
Domestic Hot Water storage
Number of units stored in the group
Average leaving water temperature
Remocon room temperature
fan
M
Louver
M
RC temperature
RC mode
nbr units
Fault
M
Fault code
M
Circulation pump operation
Flow rate
Solar pump operation
Compressor status
Desinfection operation
Setback operation
Return air temperature (Average /Min/Max)
M
Filter alarm
Termo on
M
Defrost
Hot start
Booster heater operation
3-way valve status
Coil In/Out temperature
M
Pump running hours accumulated
Compressor running hours accumulated
Actual leaving water temperature
Actual return water temperature
Actual DHW tank temperature (*)
Actual refrigerant temperature
Actual outdoor temperature
M : Modbus / R : Resistance / V : Voltage / C: Contact
* : only when room is occupied / ** : setpoint limitation / (*) if available
*** : no fan speed control on the CYV air curtain / **** : run & fault
RTD-W
M,C
M
M,V
M
RTD-LT/CA
M,C,V,R
M
M,V,R
M,V,R
M,C
M,V,R
M
M,V,R
M*
M
M,C
M
M
M
RTD-NET
M
M
RTD-10
M
M
RTD-20
M
M
RTD-HO
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
RTD-W
M,C
M
M
M
M
M
M
M,C
M
M
M
M
M
RTD-LT/CA
M,C
M
M
M
M
M
M
M,C
M
M,C
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
141
M
M,C
M
M
R
M
CONTROL
SYSTEMS
CONTROL FUNCTIONS
On/Off
Room temperature setpoint
Set point leaving water temperature (heating / cooling)
Operation mode
fan
Louver
HRV Damper control
Prohibit/Restrict functions
Forced thermo off
Domestic hot water On
Domestic Hot Water reheat
Domestic hot water reheat setpoint
Domestic Hot Water storage
Domestic hot water booster setpoint
Quiet mode
Weather dependent setpoint enable
Weather dependent curve shift
Fault/pump info relay choice
Control source prohibition
KLIC-DD
KLIC-DI
KNX interface
Integration of Split, Sky Air and VRV
in HA/BMS systems
Connect split indoor units to KNX interface for Home Automation system
Concept
light
house
Interface Daikin protocol/ KNX
Domotica
Controller
shutter control
tv
Connect Sky Air / VRV indoor units to KNX interface for BMS integration
Concept
light
shop
Interface Daikin protocol/ KNX
Domotica
Controller
shutter control
tv
KNX interface line-up
The integration of Daikin indoor units through the KNX interface allows monitoring and control of several devices, such as lights and
shutters, from one central controller. One particularly important feature is the ability to programme a ‘scenario’ - such as “Home leave” - in
which the end-user selects a range of commands to be executed simultaneously once the scenario is selected. For instance in “Home leave” ,
the air conditioner is off, the lights are turned off, the shutters are closed and the alarm is on.
KNX interface for
KLIC-DD Size 90x60x35mm
Split
KLIC-DI Size 45x45x15mm
Sky Air
VRV
BASIC CONTROL
ON/OFF
Mode
Temperature
Fan speed levels
Swing

Auto, heat, dry, fan, cool

3 or 5 + auto
Stop or movement
ADVANCED FUNCTIONALITIES
Error management
Scenes
Auto switch off
Temperature limitation
Initial configuration
Master and slave configuration




142

Auto, heat, dry, fan, cool

2 or 3
Stop or movement
Communication errors, Daikin unit errors






Auto, heat, dry, fan, cool

2 or 3
Swing or fixed positions (5)





143
CONTROL
SYSTEMS
BACnet Interface
Interfaces
Integrated control system for seamless connection between VRV,
applied Systems, air handling units and BMS systems
BMS
››
››
››
Interface for BMS system
Communication via BACnet protocol
(connection via Ethernet)
Unlimited sitesize
Easy and fast installation
PPD data is available
on BMS system (only for VRV)
VRV network
DIII- NET
BACNET / ETHERNET
››
››
Local Control
DMS502A51
VRV
Outdoor unit
HRV
up to 256 units connectable per interface
Remote Control
Applied systems network
Serial Card
BACnet MSTP
EKACBACMSTP
Serial
sequencing
panel
EKCM200J
EKCM200J
EKCM200J
EKDSSP-S
Air handling unit network
EKCMBACIP
EKCMBACMSTP
Fire alarm
BUILDING
CONTROL
NETWORK
Pump
144
Security
Lighting
Power supply facility
Elevator
LonWorks Interface
Interfaces
Open network integration of VRV and applied systems monitoring
and control functions into LonWorks networks
››
››
VRV network
LON BMS
adapter
DIII- NET
LonTalk
DMS504B51
Local Control
VRV
Outdoor unit
HRV
up to 64 units connectable per interface
Remote Control
Applied systems network
Serial card
LON FTT 10
adapter
LonTalk
EKACLONP
Serial
sequencing
panel
EKCM200J
EKCM200J
EKCM200J
EKDSSP-S
adapter
LonTalk
LonPoint
BUILDING
CONTROL
NETWORK
Security
LonPoint
Fire alarm
System
CONTROL
SYSTEMS
››
Interface for Lon connection
to LonWorks networks
Communication via Lon
protocol (twisted pair wire)
Unlimited sitesize
Quick and easy installation
ETHERNET (TCP/IP)
››
145
ACNSS
Air Conditioning
Network Service System (ACNSS)
The challenge of your technical management is
safeguarding in the long term optimal operation
of your air conditioning system without incurring
huge costs along the way. Daikin's Air Conditioning
Network Service System improves the effectiveness
of your management.
The network service system is a link via the internet,
between the air conditioning system and Daikin's
Remote Monitoring Centre. In so doing, expert
service engineers monitor the operating status of
the entire system nonstop all through the year. The
'ACNSS monitoring service' prevents troubles and
prolongs the life of your equipment.
Data
Thanks to the prediction of malfunctions and the
technical advise following from data analysis, you
not only maximise equipment availability, but also
control cost without sacrificing comfort levels.
Daikin's ACNSS is also supported by the optional
'ACNSS energy saving service' as energy use is
one of the largest operating expenses of any
business. This service enables you to optimise on
power consumption without failing to keep the
customer's amenity.
WWW.
146
ACNSS monitoringservice
ACNSS energy saving service
Comfort maintained
1 Data transmission
2 Daikin Remote Monitoring Centre
Air conditioners's running information and other
necessary data are collected and compiled, and
sent to the centre. Advance failure forecasts and
monitoring data for accidental problems are
transmitted.
Daikin's control implemented
OPTION:
energy-saving control
determination
Operating information is analyzed,
and the optimum energy-saving control
settings are calculated according to
weather data for the region.
Weather
information
Information to
customers,
service company
Reporting data is reviewed and system is monitored 24/7
for any occurances.
Energy-saving Report
Maintenance Report
Malfunction and prediction call
* A contract with Daikin is necessary for applying Energy-saving Air conditioning Network Service System. If you would like an estimation, please contact us.
147
CONTROL
SYSTEMS
3 Data analysis
& system monitoring
Daikin Configurator Software
Simplified
commissioning:
Simplified commissioning
graphical interface to
configure, commission and
upload system settings
The Daikin configurator for Daikin Altherma and
VRV is an advanced software solution that allows
for easy system configuration and commissioning:
›› Less time is required on the roof configuring
the outdoor unit
›› Multiple systems at different sites can be
managed in exactly the same way, thus offering
simplified commissioning for key accounts
›› Initial settings on the outdoor unit can be easily
retrieved
Simplified
commissioning
Retrieve initial
system settings
148
K.RSS
Wireless room temperature sensor
Flexible and easy installation
››
››
Accurate temperature measurement thanks to flexible placement of the sensor
No need for wiring
Connection diagram Daikin indoor
unit PCB (FXSQ-P example)
Power supply – X35, X13
Air sensor – X16A, X19
RF SENDER
RF RECEIVER
Specifications
WIRELESS ROOM TEMPERATURE SENSOR KIT (K.RSS)
WIRELESS ROOM TEMPERATURE RECEIVER
WIRELESS ROOM TEMPERATURE SENSOR
Dimensions
mm
Weight
g
Power supply
Battery life
Battery type
Operation range
››
16VDC, max. 20 mA
N/A
N/A
+/- 3 years
10
°C
0~50
MHz
868.3
Type
Frequency
3 Volt Lithium battery
m
RF
Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2°C or larger.
KRCS01-1B
KRCS01-4B
››
ø 75
60
N/A
Maximum range
Communication
50 x 50
40
Wired room temperature sensor
Accurate temperature measurement,
CONTROL
SYSTEMS
thanks to flexible placement of the sensor
Specifications
Dimensions (HxW)
mm
Weight
g
60 x 50
300
Length of branch wiring
m
12
149
Other integration devices
Adapter PCB’s – Simple solutions for unique requirements
Daikin’s adapter PCB’s provide simple solutions for unique requirements. They are a low cost option to satisfy simple control requirements
and can be used on single or multiple units.
(E)KRP1B*
adapter for wiring
KRP2A*/KRP4A*
Wiring adapter for
electrical appendices
DTA104A*
Outdoor Unit External
Control Adapter
››
››
Facilitates integration of auxiliary heating apparatus, humidifiers, fans, damper
Powered by and installed at the indoor unit
››
››
››
››
Remotely start and stop up to 16 indoor units (1 group) (KRP2A* via P1 P2)
Remotely start and stop up to 128 indoor units (64 groups) (KRP4A* via F1 F2)
Alarm indication/ fire shut down
Remote temperature setpoint adjustment
››
››
››
Individual or simultaneous control of VRV system operating mode
Demand control of individual or multiple systems
Low noise option for individual or multiple systems
››
Allows integration of split units to Daikin central controls
››
››
››
››
››
Switch off auto restart after power failure
Indication of operation mode / error
Remotely start /stop
Remotely change operation mode
Remotely change fan speed
››
››
››
Connect a wired remote control
Connect to Daikin central controls
Allow external contact
KRP928*
Interface adapter for
DIII-net
KRP413*
Wiring adapter normal
open contact / normal
open pulse contact
KRP980*
Adapter for split units
without an S21 port
Concept and benefits
››
››
Low cost option to satisfy simple control requirements
Deployed on single or multiple units
150
Option & accessories VRV outdoor
152
Option & accessories VRV indoor
154
Options & accessories
Stylish indoor unit
158
Options & accessories
Ventilation162
164
OPTIONS &
ACCESSORIES
Options - Control systems
151
Options & accessories
outdoor
VRV IV with continuous heating
VRV IV without con
2-module
systems
3-module
systems
RYYQ8-12T
RYYQ14-20T
RYMQ8-12T
RYMQ14-20T
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system
-
-
-
-
BHFQ22P1007
BHFQ22P1517
-
-
Extended level difference kit - Allows outdoor unit to be more than 50m above indoor units
-
-
-
-
-
-
-
-
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
water from all bottom plate outlets into a single outlet. In cold areas should be heated by
a field-supplied heater to prevent drain water from freezing in the drain pan.
-
-
-
-
-
-
-
-
EKBPH012T* +
EKBPHPCBT*
EKBPH020T* +
EKBPHPCBT*
EKBPH012T* +
EKBPHPCBT*
EKBPH020T* +
EKBPHPCBT*
-
-
EKBPH012T*
+ EKBPHPCBT*
EKBPH020T*
+ EKBPHPCBT*
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
extremely cold and humid climates
External control adapter for outdoor unit - Allows to activate Low Noise Operation
and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2
communication line and requires power supply from an indoor unit*, BSVQ box, or VRVWIII outdoor unit.
RXYQ8-12T
RXYQ14-20T
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
BHGP26A1 - Digital pressure gauge kit – displays current condensing and evaporating
pressures in the system as standard, or expansion valve positions and temperature sensor
data in a special service mode. Connect to the outdoor unit PCB, for installation in the
outdoor unit.




1 kit per
system
1 kit per
system


KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump
system, or one BS-box of a Heat Recovery system between cooling, heating and fan only.
Connects to the A-B-C terminals of the outdoor unit / BS-box.








BRP2A81 - Cool/heat selector PCB (required for VRV IV)








KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)






















-
-
-
-






-
-
-
-
-
-
-
-









-
-
-


KJB111A - Installation box for remote cool/heat selector KRC19-26A
EKPCCAB1 - VRV configurator
BPMKS967B2B/B3B - Branch provider (for connection of 2/3 RA indoor units)
KKPJ5F180 - Central drain plug
DTA104A61/62* - Demand PCB allowing external input to limit power consumption
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some outdoor units.
-
-
VRV IV-Q Heat Pump Replacement VRV
RQYQ 140
RXYQQ8-12T
RXYQQ14-20T
2-module systems
3-module systems
-
-
-
BHFQ22P1007
BHFQ22P1517
KWC26B160
-
-
-
-
-
EKBPH012T* +
EKBPHPCBT*
EKBPH020T* +
EKBPHPCBT*
-
-
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
water from all bottom plate outlets into a single outlet. In cold areas should be heated by
a field-supplied heater to prevent drain water from freezing in the drain pan.
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
extremely cold and humid climates
External control adapter for outdoor unit - Allows to activate Low Noise Operation
and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2
communication line and requires power supply from an indoor unit*, BSVQ box, or VRVWIII outdoor unit.
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
BHGP26A1 - Digital pressure gauge kit – displays current condensing and evaporating
pressures in the system as standard, or expansion valve positions and temperature sensor
data in a special service mode. Connect to the outdoor unit PCB, for installation in the
outdoor unit.



1 kit per system
1 kit per system
KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump
system, or one BS-box of a Heat Recovery system between cooling, heating and fan only.
Connects to the A-B-C terminals of the outdoor unit / BS-box.



1 kit per system
1 kit per system
BRP2A81 - Cool/heat selector PCB (required for VRV IV)
-




KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat
selector PCB and Heater tape kit are combined)
-
-




1 kit per system




-
-




1 kit per system
-



-
-
KJB111A - Installation box for remote cool/heat selector KRC19-26A
EKPCCAB1 - VRV configurator
-
DTA104A61/62* - Demand PCB allowing external input to limit power consumption
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some outdoor units.
Heat Pump
systems (2-pipe)
Heat Recovery systems (3-pipe)
Refnet Joints
Metric-size connections
Imperial-size connections
Capacity index
Capacity index
Capacity index
< 201
201~290
291~640
Capacity index
> 640
KHRQM23M20T
KHRQM23M29T
KHRQM23M64T
KHRQM23M75T
KHRQ23M20T
KHRQ23M29T9
KHRQ23M64T
KHRQ23M75T
Sound reduction kit (sound insulation)
-
-
-
-
Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one
BS-box of a Heat Recovery system between cooling, heating and fan only. Connects
to the A-B-C terminals of the outdoor unit / BS-box.
-
-
-
-
Installation box for remote cool/heat selector KRC19-26
-
-
-
-
KHRQM22M20T
KHRQM22M29T
KHRQM22M64T
KHRQM22M75T
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
Metric-size connections
Imperial-size connections
152
VRV III-S
Mini VRV
ntinuous heating
VRV III-C Cold Region VRV
VRV Classic
Total Solution VRV
VRV III Heat Recovery
2-module
systems
3-module
systems
RXYSQ
RTSYQ 10
RTSYQ
14~16
RTSYQ 20
RXYCQ8A
RXYCQ10-14A
RXYCQ16-20A
REYQ 8~16
REMQ 8~12
REMQ 14~16
REMHQ12
2-module
systems
3-module
systems
REYAQ
10~16
BHFQ22P1007
BHFQ22P1517
-
-
-
BHFQ22P1007
-
-
-
-
-
-
BHFQ23P907
BHFQ23P1357
-
-
-
-
-
-
-
-
-
-
-
-
-
KWC26B280
KWC26B450
2x KWC26B280
KWC26B160
KWC26B280
KWC26B450
KWC25C450
KWC26B280
KWC26B450
1 kit per
module
1 kit per
module
KWC25C450
-
-
-
BEH22A10Y1L
BEH22A18Y1L
2x BEH22A10Y1L
-
-
-
-
-
-
-
-
-
Special order unit
-
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units
1 kit per
system
1 kit per
system
-









1 kit per
system
1 kit per
system
-



-
-
-



-
-
-
-
-
-


-
-
-
-
-
-
-
-
-
-
-
-
-


-
-
-
-
-
-
-
-
-
-
-
-
-





-
-
-



-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-


-
-
-
-
-
-
-
-
-
-
-
-


-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
VRV-W IV Water-cooled VRV
VRV III-Q Heat Recovery Replacement VRV
Heat Pump application
Heat Recovery application
RQEQ 140~212
2-module systems
3-module systems
4-module systems
RWEYQ8-10T
2-module systems
3-module systems
2-module systems
3-module systems
-
BHFP26P36C
BHFP26P63C
BHFP26P84C
-
BHFQ22P1007
BHFQ22P1517
BHFQ23P907
BHFQ23P1357
KWC26B160
1 kit per module
1 kit per module
1 kit per module
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DTA104A62
Installation in the RWEYQ outdoor unit possible. For installation in indoor units, use appropriate type
(DTA104A53/61/62) for particular indoor unit. See Options & Accessories of indoor units
DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
See Options & Accessories of indoor units

1 kit per system
1 kit per system
1 kit per system
-
-
-
-
-
-
-
-
-

1 kit per system
1 kit per system
-
-
-
-
-
-

1 kit per system
1 kit per system
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 kit per system
-
-
-
-
-


1 kit per system
-




-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Heat Recovery Branch Selector Boxes (BS-Boxes)
Capacity index
Capacity index
Capacity index
1-port
1-port
1-port
4-port
6-port
< 291
291~640
> 640
Capacity index < 101
Capacity index 101
~ 160
Capacity index 161
~ 250
Capacity index < 100
per port
Capacity index < 100
per port
KHRQM23M29H
KHRQM23M64H
KHRQM23M75H
-
-
-
-
-
KHRQ23M29H
KHRQ23M64H
KHRQ23M75H
BSVQ100P8B
BSVQ160P8B
BSVQ250P8B
BSV4Q100PV
BSV6Q100PV
-
-
-
EKBSVQLNP
EKBSVQLNP
EKBSVQLNP
-
-
-
-
-
KRC19-26
KRC19-26
KRC19-26
KRC19-26
1 kit per port necessary
KRC19-26
1 kit per port necessary
-
-
-
KJB111A
KJB111A
KJB111A
KJB111A
KJB111A
KHRQM22M29H
KHRQM22M64H
KHRQM22M75H
-
-
-
-
-
KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
-
-
-
-
-
153
OPTIONS &
ACCESSORIES
Refnet Headers
Options & accessories
indoor
Ceiling mounted cassette units
Round flow (800x800)
4-way (600x600)
FXFQ 20~125A
FXZQ 15~50A
FXCQ 20~40A
FXCQ 50~63A
FXCQ 80 ~125A





*4
*4
*4
*4
*4
BRC7F532F
BRC7F530W *9*10 (white panel)
BRC7F530S *9*10 (grey panel)
BRC7EB530 *9*10 (standard panel)
BRC7C52
BRC7C52
BRC7C52
BRC2C51
Simplified wired remote control
-
-
-
-
-
BRC3A61
Remote control for hotel use
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
BRC1D52
Standard wired remote control with weekly timer
Adapters and control
Infrared remote control including receiver
-
-
-
-
-
DCS302C51
Central remote control





DCS301B51
Unified ON/OFF control





DST301B51
Schedule timer





DCS601C51
Intelligent Touch Manager
External wired temperature sensor
External wireless temperature sensor





KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A53 *2*7
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
-
KRP2A52
KRP2A51
KRP2A51
KRP2A51
Wiring adapter with 4 output signals
(Compressor / Error, Fan, Aux. heater, Humidifier output)
EKRP1C11 *2*7
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
Wiring adapter with 2 output signals
(Compressor / Error, Fan output)
KRP1B57 *2*7
KRP1B57
-
-
-
Adapter for multi-tenant applications
(24VAC PCB power supply interface)
DTA114A61
DTA114A61
-
-
-
Wiring adapter for external monitoring/control via dry contacts and
setpoint control via 0-140Ω
Wiring adapter for external central monitoring/control
(controls 1 entire system)
External control adapter for outdoor unit
-
-
DTA104A61
DTA104A61
DTA104A61
KRP1H98 *7
KRP1A101
KRP1C96
KRP1C96
KRP1C96
Connector for forced-off contact
standard
-
standard
standard
standard
Connection to centralized control
standard
-
-
-
-
Electrical box with earth terminal (2 blocks)
KJB212A
-
KJB212A
KJB212A
KJB212A
Electrical box with earth terminal (3 blocks)
KJB311A
-
KJB311A
KJB311A
KJB311A
BYBCQ40H
BYBCQ63H
BYBCQ125H
Installation box / Mounting plate for adapter PCBs
(For units where there is no space in the switchbox)
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
Others
2-way blow
BYCQ140D7GW1 (self clean) *5/*6 BYFQ60CW (white panel)
BYCQ140D7W1W (white) *3
BYFQ60CS (grey panel)
BYCQ140D7W1 (standard) BYFQ60B3 (standard panel)
Kit for mounting of decoration panel direct onto unit
-
-
-
-
-
Panel spacer for reducing required installation height
-
KDBQ44B60
(standard panel)
-
-
-
KDBHQ55B140 *7
BDBHQ44C60 (white & grey panel)
-
-
-
KDDQ55B140-1 +
KDDQ55B140-2 *7*8
KDDQ44XA60
-
-
-
-
-
-
-
-
Sealing kit for 3-directional or 2-directional air discharge
Fresh air intake kit
Air discharge adapter for round duct
Filter chamber for bottom suction
Replacement long life filter
Drain pump kit
Sensor kit
Noise filter (for electromagnetic use only)
-
-
KDDFP53B50
KDDFP53B80
KDDFP53B160
KAFP551K160
KAFQ441BA60
KAFP531B50
KAFP531B80
KAFP531B160
standard
standard
standard
standard
standard
BRYQ140A
BRYQ60AW (white panel)
BRYQ60AS (grey panel)
-
-
-
-
-
KEK26-1A
KEK26-1A
KEK26-1A
*2 Installation box is necessary for these adapters
*3 The BYCQ140D7W1W has white insulation
Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install
the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt"
*4 Not recommended because of the limitation of the functions
*5 To be able to control the BYCQ140D7GW1 the controller BRC1E is needed
*6 The BYCQ140DGW1 is not compatible with Mini VRV, Multi and Split Non-Inverter Outdoor units
*7 Option not available in combination with BYCQ140D7GW1
*8 Both parts of the fresh air intake are needed for each unit
*9 Sensing function not available
*10 Independently controllable flaps function not available
154
Concealed ceiling units (duct units)
Corner (1-way blow)
Small
Slim
Standard
FXKQ 25~40
FXKQ 63
FXDQ 20~25 M9
FXDQ 15~63A
FXSQ 20~32
FXSQ 40~50
FXSQ 63~80
FXSQ 100~140








*4
*4
*4
*4
*4
*4
*4
*4
BRC4C61
BRC4C61
BRC4C62
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
-
-






-
-






































KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-4B
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A51
KRP4A51
KRP4A54
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A51
KRP2A51
KRP2A51
KRP2A53
KRP2A61
KRP2A51
KRP2A51
KRP2A51
KRP1B61
KRP1B61
EKRP1B2
KRP1B56
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
-
-
-
-
-
-
-
-
-
-
EKMTAC
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
DTA104A53
DTA104A61
DTA104A61
DTA104A61
DTA104A61
-
-
-
KRP1B101
KRP4A96
KRP4A96
KRP4A96
KRP4A96
Standard
Standard
Standard
-
Standard
Standard
Standard
Standard
Standard
Standard
Standard
-
Standard
Standard
Standard
Standard
-
-
-
KJB212A
-
-
-
-
-
-
-
KJB311A
-
-
-
-
BYK45F
BYK71F
-
-
BYBS32D
BYBS45D
BYBS71D
BYBS125D
-
-
-
-
EKBYBSD
EKBYBSD
EKBYBSD
EKBYBSD
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDAJ25K36A
KDAJ25K56
KDAJ25K71
KDAJ25K140
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Standard
Standard
KDAJ25K56
standard
Standard
Standard
Standard
Standard
-
-
-
-
-
-
-
-
-
-
-
KEK26-1A
-
-
-
-
OPTIONS &
ACCESSORIES
K.RSS
KRP4A51
155
Options & accessories
indoor
Concealed ceiling units (duct units)
High ESP
BRC1E52A/B
Premium wired remote control with full-text interface and back-light
BRC1D52
Standard wired remote control with weekly timer
Adapters and control
FXMQ 40
FXMQ 50~80
FXMQ 100~125
FXMQ 200~250





*4
*4
*4
*4
*4
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC2C51
Simplified wired remote control





BRC3A61
Remote control for hotel use





DCS302C51
Central remote control





DCS301B51
Unified ON/OFF control





DCS601C51
Schedule timer





Infrared remote control including receiver
Others
Large
FXMQ 20~32
DCS301B51
Intelligent Touch Controller
External wired temperature sensor
External wireless temperature sensor





KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-1
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
Wiring adapter for external monitoring/control via dry contacts and
setpoint control via 0-140Ω
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
Wiring adapter for external central monitoring/control
(controls 1 entire system)
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
Wiring adapter with 4 output signals
(Compressor / Error, Fan, Aux. heater, Humidifier output)
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
KRP1B61
Wiring adapter with 2 output signals
(Compressor / Error, Fan output)
-
-
-
-
-
Adapter for multi-tenant applications
(24VAC PCB power supply interface)
DTA114A61
DTA114A61
DTA114A61
DTA114A61
-
External control adapter for outdoor unit
DTA104A61
DTA104A61
DTA104A61
DTA104A61
DTA104A61
Installation box / Mounting plate for adapter PCBs
(For units where there is no space in the switchbox)
KRP4A96
KRP4A96
KRP4A96
KRP4A96
-
Connector for forced-off contact
Standard
Standard
Standard
Standard
Standard
Connection to centralized control
Standard
Standard
Standard
Standard
Standard
Electrical box with earth terminal (2 blocks)
-
-
-
-
-
Electrical box with earth terminal (3 blocks)
-
-
-
-
-
Decoration panel
(obligatory for cassette units, optional for others, rear panel for FXLQ)
BYBS32D
BYBS45D
BYBS71D
BYBS125D
-
Kit for mounting of decoration panel direct onto unit
EKBYBSD
EKBYBSD
EKBYBSD
EKBYBSD
-
Panel spacer for reducing required installation height
-
-
-
-
-
Sealing kit for 3-directional or 2-directional air discharge
-
-
-
-
-
Decorationpanel for air discharge
-
-
-
-
-
Fresh air intake kit
-
-
-
-
-
KDAJ25K36A
KDAJ25K56
KDAJ25K71
KDAJ25K140
-
-
-
-
-
-
Air discharge adapter for round duct
Replacement long life filter
Drain pump kit
Standard
Standard
Standard
Standard
-
Sensor kit
-
-
-
-
-
Noise filter (for electromagnetic use only)
-
-
-
-
-
L-type piping kit (for upward direction)
-
-
-
-
-
*2 Installation box is necessary for these adapters
*3 The BYCQ140D7W1W has white insulation
Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install
the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt
*4 Not recommended because of the limitation of the functions
*5 To be able to control the BYCQ140D7GW1 the controller BRC1E is needed
*6 The BYCQ140DGW1 is not compatible with Mini VRV, Multi and Split Non-Inverter Outdoor units
*7 Option not available in combination with BYCQ140D7GW1
*8 Both parts of the fresh air intake are needed for each unit
*9 Sensing function not available
*10 Independently controllable flaps function not available
156
Ceiling suspended units
1-way blow
Wall mounted units
4-way blow
Floor standing units
Concealed
Free-standing
FXHQ 32A
FXHQ 63A
FXHQ 71~100A
FXUQ 71~100A
FXAQ 15~63
FXNQ 20~63
FXLQ 20~25
FXLQ 32~40
FXLQ 50~63









*4
*4
*4
*4
*4
*4
*4
*4
*4
BRC7G53
BRC7G53
BRC7G53
BRC7C58
BRC7E618
BRC4C65
BRC4C65
BRC4C65
BRC4C65
-
-
-
-
-




-
-
-
-
-
-
-
-
-




































KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A52
KRP4A52
KRP4A52
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A62
KRP2A62
KRP2A62
-
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
-
-
-
-
-
KRP1B61
KRP1B61
KRP1B61
KRP1B61
KRP1B54
KRP1B54
KRP1B54
-
-
-
-
-
-
-
-
-
-
DTA114A61
EKMTAC
EKMTAC
EKMTAC
EKMTAC
DTA104A62
DTA104A62
DTA104A62
-
DTA104A61
-
-
-
-
KRP1D93A
KRP1D93A
KRP1D93A
KRP1B97
KRP4A93
-
-
-
-
EKRORO4
EKRORO4
EKRORO4
EKRORO5
Standard
Standard
Standard
Standard
Standard
-
-
-
-
Standard
Standard
Standard
Standard
Standard
KJB212A
KJB212A
KJB212A
KJB212A
-
-
-
-
-
KJB311A
KJB311A
KJB311A
KJB311A
-
-
-
-
-
-
-
-
-
-
-
EKRDP25A
EKRDP40A
EKRDP63A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDBHP49B140
-
-
-
-
-
-
-
KDBTP49B140
-
-
-
-
-
KDDQ50A140
KDDQ50A140
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KAFP501A56
KAFP501A80
KAFP501A160
KAFP551K160
-
-
-
-
-
KDU50P60
KDU50P140
KDU50P140
-
K-KDU572EVE
-
-
-
-
-
-
-
-
-
-
-
-
-
KEK26-1
KEK26-1
KEK26-1
-
-
-
-
-
-
KHFP5M35
KHFP5N63
KHFP5N160
-
-
-
-
-
-
OPTIONS &
ACCESSORIES
KDDQ50A140
157
Options & accessories
Stylish indoor units
INDOOR UNITS - CONTROL SYSTEMS
FTXG20L
FTXG25L
Wired remote control
Wireless remote control
FTXG35L
FTXG50L
FTXG35L
FTXG50L
BRC944 (3)
-
Simplified remote control
-
Remote control for hotel use
3m
Cord for wired remote control
BRCW901A03
8m
BRCW901A08
Wiring adapter normal open contact / normal open pulse contact
Centralised control board
KRP413A1S (1)
Up to 5 rooms
KRC72 (2)
Anti-theft protection for remote control
KKF910A4
Central remote control
DCS302C51
Unified on/off control
DCS301B51
Schedule timer
DST301B51
Wiring adapter for electrical appendices
-
Remote sensor
-
Installation box for adapter PCB
-
Electric box with earth terminal 2 / 3 blocks
-
Interface adapter for DIII-net
KRP928A2S
Online controller
BRP069A41
External mounting kit for online controller
-
Wifi power cable for online controller
-
Touch LCD wall controller (4)
-
Simple wall controller (4)
-
KNX gateway
KLIC-DD
INDOOR UNITS
FTXG20L
FTXG25L
Photocatalytic deodorising filter, with frame
Photocatalytic deodorising filter, without frame
-
Air purification filter, with frame
-
Notes
(1) Wiring adapter supplied by Daikin. Time clock and other devices : to be purchased locally.
(2) Wiring adapter is also required for each indoor unit.
(3) Cord for wired remote control BRCW901A03 or BRCW901A08 required.
(4) Can only be used in combination with online controller KKRP01A.
(5) Standard there is no remote control delivered with this indoor unit. Wired or wireless control to be ordered separately.
INDOOR UNITS - CONTROL SYSTEMS
CTXS15K
FTXS20K
FTXS25K
Wired remote control (3)
Cord for wired remote control
3m
8m
FTXS42K
FTXS50K
KRP413A1S (6)
Up to 5 rooms
KRC72 (2)
Anti-theft protection for remote control
KKF910A4
Interface adapter for wired remote control
KRP980A1
Central remote control
DCS302C51
Unified on/off control
DCS301B51
Schedule timer
DST301B51
Interface adapter for DIII-net
KRP928A2S (6)
Online controller
KKRP01A
External mounting kit for online controller
KKRPM01A
Wifi power cable for online controller
KKRPW01A
Touch LCD wall controller (4)
KBRC01A
Simple wall controller (4)
KBRCS01A
KNX gateway
KLIC-DD (6)
INDOOR UNITS
FTXS35K
BRCW901A08
Wiring adapter normal open contact / normal open pulse contact
Centralised control board
CTXS35K
BRC944 (3) (6)
BRCW901A03
CTXS15K
FTXS20K
Titanium apatite photocatalytic air-purification filter without frame
Installation leg
FTXS25K
CTXS35K
-
Notes
(1) Wiring adapter supplied by Daikin. Time clock and other devices : to be purchased locally.
(2) Wiring adapter is also required for each indoor unit.
(3) Cord for wired remote control BRCW901A03 or BRCW901A08 required.
(4) Can only be used in combination with online controller KKRP01A.
(5) Standard there is no remote control delivered with this indoor unit. Wired or wireless control to be ordered separately.
(6) Interface adapter KRP980A1 required.
158
FTXS35K
FTXS42K
FTXS50K
FDXS35F
FDXS50F9
FDXS60F
FVXS25F
BRC1D52 / BRC1E52A / BRC1E52B (5)
BRC4C65
FDXS25F
FVXS35F
FVXS50F
FLXS25B
FLXS35B9
-
FLXS50B
BRC2C51
-
-
BRC3A61
-
-
-
-
-
-
-
-
-
KRP413A1S (1)
KRP413A1S (1)
-
KRC72 (2)
KRC72 (2)
-
-
KKF917AA4
DCS302C51
DCS302C51
DCS302C51
DCS301B51
DCS301B51
DCS301B51
DST301B51
DST301B51
DST301B51
KRP4A54
-
-
KRCS01-4
-
-
KRP1BA101
-
-
KJB212A / KJB311A
-
-
-
KRP928A2S
KRP928A2S
-
KKRP01A
KKRP01A
-
KKRPM01A
KKRPM01A
-
KKRPW01A
KKRPW01A
-
KBRC01A
KBRC01A
-
KBRCS01A
KBRCS01A
-
KLIC-DD
KLIC-DD
FDXS35F
FDXS50F9
FDXS60F
FVXS25F
FVXS35F
FVXS50F
FLXS25B
FLXS35B9
-
-
KAZ917B41
KAZ917B42
-
-
KAF925B41
FTXS60G
FTXS71G
FVXG25K
FVXG35K
BRC944 (3)
BRCW901A03
FLXS50B
FLXS60B
FVXG50K
BRC944 (3)
BRCW901A03
BRCW901A08
BRCW901A08
KRP413A1S (1)
KRP413A1S (1)
KRC72 (2)
KRC72 (2)
KKF910A4
KKF910A4
-
-
DCS302C51
DCS302C51
DCS301B51
DCS301B51
DST301B51
DST301B51
KRP928A2S
KRP928A2S
KKRP01A
KKRP01A
KKRPM01A
KKRPM01A
KKRPW01A
KKRPW01A
KBRC01A
KBRC01A
KBRCS01A
KBRCS01A
KLIC-DD
KLIC-DD
FTXS60G
FLXS60B
-
FTXS71G
FVXG25K
FVXG35K
-
FVXG50K
BKS028
OPTIONS &
ACCESSORIES
FDXS25F
159
Options & accessories
Stylish indoor units
INDOOR UNITS - CONTROL SYSTEMS
FCQG35F
FCQG50F
FCQG60F
Wired remote control
I-touch controller
Infrared remote control (heat pump)
Remote control for hotel use
Centralised remote control
Unified ON/OFF control
Schedule timer
Adapter for wiring (interlock for fresh air intake fan)
Adapter for external ON/OFF and monitoring/for electrical appendices
Installation box for adapter PCB
Remote sensor
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
Adapter for wiring (hour meter)
Options PCB for external electrical heater, humidifier and/or hour meter
Notes
(1) Installation box for adapter PCB is necessary
(2) Interface adapter for Sky Air series (DTA112B51) is necessary
(3) Including following languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish, Purtuguese, Polish
(4) Including following languages: English, German, Czech, Croatian, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian.
(5) Option not available in combination with BYCQ140*G
(6) Installation box for adapter PCB (KRP1B101) is necessary
(7) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.
(8) Sensing function is not available
(9) Independently controllable flaps function is not available
INDOOR UNITS
FCQG35F
FCQG50F
FCQG71F
FCQG100F
FCQG125F
FCQG140F
FCQG100F
FCQG125F
FCQG140F
BRC1D52 /
BRC1E52A (3) /
BRC1E52B (4)
DCS601C51
BRC7FA532F (5)
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B57/KRP4A53 (1)(5)
KRP1H98 (5)
KRCS01-4
KJB311A
KJB212A
EKRP1C11 (1)(5)
-
FCQG60F
FCQG71F
Replacement long-life filter
KAFP551K160
Drain pump kit
Standard
Sealing member of air discharge outlet
KDBHQ55B140 (4)
Decoration panel
BYCQ140D + BYCQ140DW(1) + BYCQ140DG (2)(3)
Kit for mounting of decoration panel direct onto unit
Fresh air intake kit (direct installation type)
KDDQ55B140-1 (4)+ KDDQ55B140-2 (6)
Air discharge adapter for round duct
Panel spacer
Sensor kit
BRYQ140A (5)
Notes
(1) The BYCQ140DW has white insulations. Be informed that dirt is more visible on white insulation and that it is consequently not advised to install the BYCQ140DW decoration panel in environments exposed to concentrations of dirt.
(2) To be able to control the BYCQ140DG, the controller BRC1E* is needed
(3) The BYCQ140DG is only compatible with Sky Air RZQ(G), RZQS(G); All VRV outdoors; Split RKS, RXS
(4) Option not available in combination with BYCQ140DG
(5) Sensor kit can only be operated with BRC1E52A/B
(6) BYFQ60B2 = basic , BYFQ60CW = White , BYFQ60CS = Grey
(7) BRYQ60AW = White, BRYQ60AS = Grey
INDOOR UNITS - CONTROL SYSTEMS
FHQ35C
FHQ50C
FHQ60C
FHQ71C
FHQ100C
FHQ125C
Wired remote control
BRC1D52 / BRC1E52A (3) / BRC1E52B (4)
Infrared remote control (heat pump)
BRC7G53
Centralised remote control
DCS302C51
Unified ON/OFF control
DCS301B51
Schedule timer
DST301B51
Adapter for external ON/OFF and monitoring/for electrical appendices
KRP1B54 / KRP4A52(1)
Installation box for adapter PCB
KRP1D93A
Remote sensor
KRCS01-4B
Remote ON/OFF, forced OFF
EKRORO4
Electrical box with earth terminal (3 blocks)
KJB311A
Electrical box with earth terminal (2 blocks)
KJB212A
Options PCB for external electrical heater, humidifier and/or hour meter
Notes
(1) Installation box for adapter PCB is necessary
(2) Interface adapter for Sky Air series (DTA112B51) is necessary
(3) Including following languages: English, German, French, Italian, Spanish, Dutch, Greek, Russian, Turkish, Purtuguese, Polish
(4) Including following languages: English, German, Czech, Croatian, Hungarian, Romanian, Slovenian, Bulgarian, Slovak, Serbian, Albanian.
INDOOR UNITS
Replacement long-life filter
Drain pump kit
L-type piping kit (upward direction)
Fresh air intake kit (direct installation type)
FHQ35C
FHQ50C
KAFP501A56
KDU50P60
KHFP5M35
KHFP5N63
FHQ60C
FHQ71C
KAFP501A80
KDDQ50A140
160
FHQ100C
FHQ125C
KAFP501A160
KDU50P140
KHFP5N160
FHQ140C
FFQ35C
FFQ50C
FFQ60C
BRC1D52 /
BRC1E52A (3) /
BRC1E52B (4)(9)
DCS601C51
BRC7EB530/BRC7F530W/BRC7F530S (8-9)
DCS302B51
DCS301B51
DST301B51
KRP1B57/KRP4A53(6)
KRP1B101/ KRP1BA101
KRCS01-4
EKRP1B2
-
FFQ25C
FFQ35C
FFQ50C
KAFQ441BA60
Standard
BDBHQ44C60
BYFQ60B3/BYFQ60CW/BYFQ60CS (6)
KDDQ44XA60
KDBQ44B60
BRYQ60AW/BRYQ60AS (7)
FDBQ25B
FBQ35C8
FBQ50C8
FBQ60C8
BRC1D52 /
BRC1E52A (3)
BRC1E52B (4)
EKRP1B2
-
FFQ60C
FDBQ25B
-
FBQ71C8
FBQ100C8
FBQ125C8
FBQ140C8
FBQ100C8
FBQ125C8
FBQ140C8
BRC1D52 /
BRC1E52A (3/
BRC1E52B (4)
DCS601C51 (2)
BRC4C65
BRC3A61
DCS302C51
DCS301B51
DST301B51
KRP1B54
KRP4A51/KRP2A51
KRCS01-1
EKRP1B2A (7)
FBQ35C8
FBQ50C8
FBQ60C8
FBQ71C8
Standard
-
BYBS45D
BYBS71D
KDAJ25K56A
EKBYBSD
KDAJ25K71A
-
BYBS125D
KDAJ25K140A
OPTIONS &
ACCESSORIES
FFQ25C
161
Options & accessories
Ventilation
OPTIONS
Dust filters
Silencer
VAM150FA
VAM250FA
VAM350FB
VAM500FB
VAM650FB
EN779 Medium M6
-
-
EKAFV50F6
EKAFV50F6
EKAFV80F6
EN779 Fine F7
-
-
EKAFV50F7
EKAFV50F7
EKAFV80F7
EN779 Fine F8
-
-
EKAFV50F8
EKAFV50F8
EKAFV80F8
Model name
-
-
-
-
KDDM24B100
Nominal pipe Diameter (mm)
-
-
-
200
200
-
-
BRYMA65
BRYMA65
BRYMA65
VH1B
VH2B
VH2B
VH3B
VH3B
CO2 sensor
VH electrical heater for VAM
INDIVIDUAL CONTROL SYSTEMS
Wired remote control
VAM-FA/FB
VKM-GB(M)
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52
BRC301B61
-
VAM wired remote control
CENTRALISED CONTROL SYSTEMS
VAM-FA/FB
VKM-GB(M)
Centralised remote control
DCS302C51
DCS302C51
Unified ON/OFF control
DCS301B51
DCS301B51
Schedule timer
DST301B51
DST301B51
OTHERS
Wiring adapter for electrical appendices (6)
Adapter PCB for humidifier
Adapter PCB for 3rd party heater
VAM150-250FA
VAM350-2000FB
VKM-GB(M)
KRP2A51 (6)
KRP50-2
KRP2A51 (3)
BRP4A50A (4/5)
BRP4A50A (4/5)
BRP4A50A (4/5)
BRP4A50
BRP4A50A (4/5)
BRP4A50A (4/5)
-
-
-
Remote sensor
Notes
(1) Cool/heat selector required for operation
(2) Do not connect the system to DIII-net devices (Intelligent controller, Intelligent Manager, LonWorks interface, BACnet interface…)
(3) Installation box KRP1BA101 needed for VAM350-2000FB
(4) Fixing plate EKMPVAM additionally needed for VAM1500-2000FB
(5) 3rd party heater and 3rd party humidifier cannot be combined
(6) For external control and monitoring (ON/OFF control, operation signal, error indication)
VH ELECTRICAL HEATER FOR VAM
Supply voltage
Output current (maximum)
Temperature sensor
Temperature control range
Run on timer
Control fuse
220/250V ac 50/60 Hz. +/-10%
19A at 40°C (ambient)
5k ohms at 25°C (table 502 1T)
0 to 40°C / (0-10V 0-100%)
Adjustable from 1 to 2 minutes (factory set at 1.5 minutes)
20 X5 mm 250 m A
LED indicators
Power ON - Yellow
Heater ON - Red (solid or flashing, indicating pulsed control)
Airflow fault - Red
Mounting holes
Maximum ambient adjacent to terminal box
Auto high temp. cutout
Man. reset high temp. cutout
Run relay
BMS setpoint input
VH ELECTRICAL HEATER FOR VAM
Capacity
Duct diameter
Connectable VAM
kW
mm
98mm X 181mm centres 5 mm ø holes
35°C (during operation)
100°C Pre-set
125°C Pre-set
1A 120V AC or 1A 24V DC
0-10VDC
VH1B
VH2B
VH3B
VH4B
VH4/AB
VH5B
1
100
VAM150FA
1
150
VAM250FA
VAM350FB
1
200
VAM500FB
VAM650FB
1.5
250
VAM800FB
VAM1000FB
2.5
250
VAM800FB
VAM1000FB
2.5
350
VAM1500FB
VAM2000FB
-
162
VAM800FB
VAM1000FB
VAM1500FB
VAM2000FB
VKM50GB(M)
VKM80GB(M)
VKM100GB(M)
EKAFV80F6
EKAFV100F6
EKAFV80F6 x2
EKAFV100F6 x2
-
-
-
EKAFV80F7
EKAFV100F7
EKAFV80F7 x2
EKAFV100F7 x2
-
-
-
EKAFV80F8
EKAFV100F8
EKAFV80F8 x2
EKAFV100F8 x2
-
-
-
KDDM24B100
KDDM24B100
KDDM24B100 x2
KDDM24B100 x2
-
KDDM24B100
KDDM24B100
250
250
250
250
-
250
250
BRYMA100
BRYMA100
BRYMA200
BRYMA200
BRYMA65
BRYMA100
BRYMA200
VH4B / VH4/AB
VH4B / VH4/AB
VH5B
VH5B
-
-
-
FXMQ-MF
EKEQFCB (2)
EKEQDCB (2)
EKEQMCB (2)
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52
BRC1E52A/B / BRC1D52 (1)
BRC1E52A/B / BRC1D52 (1)
-
-
-
-
FXMQ-MF
EKEQFCB (2)
EKEQDCB (2)
DCS302C51
-
-
-
DCS301B51
-
-
-
DST301B51
-
-
-
FXMQ-MF
EKEQFCB (2)
EKEQDCB (2)
EKEQMCB (2)
-
-
-
-
-
-
-
KRCS01-1
OPTIONS &
ACCESSORIES
-
EKEQMCB (2)
163
Options - Control systems
DCM601A51
iTM plus adapter
DCM601A52
iTM integrator
DCM601A53
iTM ppd software
DCM002A51
iTM energy navigator software
Modbus communication unit
787-712
750-613
Connector:
750-960
WAGO I/O
750-600
750-513/000-001, 750-504
Ai module:
750-454, 750-479, 750-455,
750-459, 750-461, 750-61/000-003,
750-461/000-004, 750-461/
000-005, 750-460, 750-460/
000-003, 750-460/000-005
Ao module:
750-555, 750-559, 750-554,
750-560
Thermistor module:
BACnet Interface
750-400, 750-432, 750-430
Do module:
Pi module:
LonWorks Interface
DCM008A51
DC24V power supply unit:
Di module:
DMS502A51
WGDCMCPLR
DC24V power supply unit:
Terminator module:
DMS504B51
750-638
750-461/020-000
Interface adapter for connection to RA units
KRP928A2S
KRP928A2S
Interface adapter for connection to R-407C/R-22 Sky Air units
DTA102A52
DTA102A52
Interface adapter for connection to R-410A Sky Air units
DTA112B51
DTA112B51
DIII board
DAM411B51
Digital input/output
DAM412B51
164
165
OPTIONS &
ACCESSORIES
Over 30 years of
VRV History
The original VRV air conditioning
system developed by Daikin
Industries Ltd. in 1982 is
introduced into Europe in VRV
standard format. VRV D series can
supply conditioned air from up to
6 indoor units connected to
a single outdoor unit.
1987
1991
A further step forward
is taken in 1991 with the
introduction of the
VRV heat recovery system,
offering simultaneous cooling
and heating from different
indoor units on the same
refrigeration circuit.
The introduction
of the VRVII-S series extends
the VRV operating scope
into the light commercial
sectors. Available in 4, 5 and
6HP capacities, the system is
designed for installation in
up to 9 rooms.
In anticipation of phase out dates
for all CFC based equipment,
Daikin Europe launched a VRV
interter series with R-407C.
As many as 16 indoor units can be
connected to 1 single outdoor unit.
1994
1998
Consistent high quality and
efficiency lead to the widespread acceptance of the VRV
concept and Daikin becomes the
first Japanese air conditioning
manufacturer to be awarded the
ISO9001 certification.
166
PB
2003
2004
Daikin introduces the VRVII,
the world’s first R-410A
operated variable refrigerant
flow system. Available in cooling
only, heat pump and heat recovery
versions. No less than 40 indoor
units in heat recovery as well as
heat pump format can be
connected to a single refrigerant
circuit.
2005
Daikin Daikin extends
the operational scope of
its acclaimed VRVII inverter
driven dx air conditioning
system, with a new water
cooled version, VRV-WII.
Available in both heat pump
and heat recovery versions.
2006-2007
Daikin extends the VRVIII range
with the water cooled VRV-WIII.
A geothermal version is also
available now.
This system uses geothermal heat
as a renewable energy source
and can operate down to -10°C in
heating mode.
2008
Daikin announces the third
generation of its much acclaimed
VRV range with the extensively
re-engineered VRVIII. Available
in heat recovery, heat pump and
cooling versions, VRVIII incorporates
all the best features of earlier VRV
systems. However, it also possesses
a considerable number of new
design, installation and maintenance
refinements such as automatic
charging and testing.
Up to 64 indoor untis
can be connected to
one system.
2009
2010
Daikin extends its VRV range
with the innovative replacement
VRV – a highly cost effective
replacement for VRV systems still
operating on the banned
R-22 refrigerant. This cost effective
upgrade is possible because
VRVIII-Q outdoor units can be
installed using existing piping and
in some cases existing indoor units.
PB
Daikin launches the ‘total solution’ concept
by integrating hot water production and
Biddle air curtains in the VRV system. The
range of indoor units is also expanded by
offering the possibility to connect residential
indoor units as Daikin Emura or Nexura to
the VRV system. 2011 also confirms VRV as
established solution in the market reaching
400,000 outdoor units and
2.2 million indoor units sold.
2011
2012
The fourth generation
of VRV is launched. The unit sets
new standards in the industry
with 28% better seasonal
efficiency and continuous heating
on heat pumps.
HISTORY
AND R&D
Daikin introduces a new heat
pump range optimised for
heating (VRVIII-C).
This new range has an
extended operation range
down to -25°C and has a
greatly improved COP in low
ambient temperatures, with
the newly developed 2-stage
compressor system.
Research & development
Creating value through innovative technologies
R&D is essential for the creation of products that enrich people's lives. As symbolised by the VRV, Daikin is at the forefront of innovative
technology and the development of market leading products: the result of our advanced R&D system.
Superior products from multi-part development approach
To create more advanced functions with added value, Daikin
has set up the 'Environmental Technology Research Laboratory'
and the 'Solution Product Development Center'. Working with
the Product Development Group, the three divisions cooperate
closely to ascertain and meet the customers' needs and to enable
commercialisation of products incorporating advanced technology.
Development
Product Development Group
IT
Solution Product
Development Center
Intensive research on environmental impact
The diverse needs in different countries encountered during the
accelerating globalisation of our air conditioning business have
presented us with increased research challenges particularly in
terms of environmental impact. To promote energy savings in
and to lower the environmental impact of our air conditioners, we
have developed technologies based on fundamental research into
motor inverters and many other areas.
168
PB
Development
Environmental Technology
Research laboratory
IT and air conditioners:
the obvious solution With advances in computerisation and networking, we have
integrated IT into our air conditioners including communication
technology and advanced software for total control.
Our new control systems enable users to develop comfortable
environments with superior energy savings by networking air
conditioners to enable them to exchange information with each
other and with our service centres.
Environment
Five-year results for
the environmental action
plan 2010
Europe
Fifteen-fold increase in heat-pump hot water and space
heating
We have successfully promoted the use of the Daikin Altherma hot
water and space heating system in the process contributing to the
reduction of 210,000 tons of CO2 emissions.
Under the five-year FUSION 10 strategic management plan, which
targeted fiscal year 2010, the Daikin Group strove to develop
and promote the use of environmentally conscious products
and services on a basic policy of actively contributing to solving
global environmental problems and expanding business. Our
environmental measures were conducted under our Environmental
Action Plan 2010.
Proliferating results
Units of Daikin ALtherma
sold in Europe
Reducing Environmental
Impact from products
Heat pump heaters as
percentage of all heaters sold
in Europe
Reduction of
210,000 tons of
CO2 emissions
compared
to using
combustiontype heaters
Five year result
Promote and expand the use of environmentally conscious
products to meet the particular needs of each world region.
15 times
We have developed and provided air conditioner products and
services that meet the environmental needs of each world region
in terms of weather, culture, and economy.
2006
Five years target
2010
HEAT PUMP
HEATERS 4%
FY 2010
FY
Promote the use of environmentally conscious products,
particularly in rapidly growing developing countries
PB
HISTORY
AND R&D
Daikin will continue to provide air conditioning products and
services that meet the environmental needs of each world region.
Particularly in developing countries, which are growing fast but
where increasing environmental impact is a problem, Daikin will
provide products and technologies that contribute to economic
progress yet still protect the environment.
Notes
170
171
360°
Heat Recovery
efficiency
installation
efficiency
design
efficiency
operational
efficiency
FAST
design
QUICK +
+ installation
MORE
free heat
+
MAX
comfort
Our new VRV IV heat recovery systems sets pioneering
standards in all-round climate comfort efficiency.
Total design simplicity, rapid installation, full flexibility
with absolute efficiency and comfort. Find out about all
revolutionary changes on www.daikineurope.com/vrviv
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this leaflet to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this leaflet.
All content is copyrighted by Daikin Europe N.V.
Daikin products are distributed by:
ECPEN14-200
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
ECPEN14-200 • XXX • 03/14 • Copyright Daikin
The present publication supersedes ECPEN13-200.
Printed on non-chlorinated paper. Prepared by La Movida, Belgium
Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
FSC
VRV products are not within the scope of the Eurovent certification programme.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement