à õ õ
CONTRIVE S.R.L.
Via Enrico Fermi 18 I-24040 SUISIO (Bergamo)
Tel. +39 (0)35 4948236 Fax +39 (0)35 4933759
B3011.EN / 0907
SAFETY INFORMATION
Do not install this unit near medical devices like pacemakers or hearing
aids. This unit may interfere with the operation of these devices.
www.gsm-control.biz
i
GSM REMOTE HVAC CONTROL
Switch off this unit when flying.
Secure it so that it cannot be switched on inadvertently.
Do not install this unit near petrol stations, fuel depots, chemical plants or
blasting operations when this unit can disturb the operation of technical
equipment.
GprsComfort2+
GSM/GPRS REMOTE HVAC CONTROL
This unit can be installed on any standard EN-50022 rail by simple snap-in.
A minimum protection degree IP40 must be guaranteed, raised to IP54 for openair application.
A. Power Supply input
2 x 2,5mm2 (AWG14)
õ
GsmComfort2+
INSTALLATION
X
Interference can occur if this unit is used near televisions, radios or
personal computers.
If the device has been stored in a cold environment, then condensation can
occur. Before starting operations, the device must be absolutely dry.
Thus, an acclimatization period of at least three hours must be observed.
r
USER GUIDE
3011.01.00
3011.02.00
3011.01.01
3011.02.01
3011.01.10
3011.02.10
3011.01.11
3011.02.11
3011.01.02
3011.02.02
3011.01.03
3011.02.03
3011.01.12
3011.02.12
3011.01.13
3011.02.13
GsmComfort2+A EMBEDDED
B
GsmComfort2+A EMBEDDED
GsmComfort2+X EXTERNAL
B
GsmComfort2+X EXTERNAL
GprsComfort2+A EMBEDDED
B
GprsComfort2+A EMBEDDED
GprsComfort2+X EXTERNAL
B
GprsComfort2+X EXTERNAL
GsmComfort2+PA EMBEDDED
B
GsmComfort2+PA EMBEDDED
GsmComfort2+PX EXTERNAL
B
GsmComfort2+PX EXTERNAL
GprsComfort2+PA EMBEDDED
B
GprsComfort2+PA EMBEDDED
GprsComfort2+PX EXTERNAL
B
GprsComfort2+PX EXTERNAL
ANTENNA
ANTENNA + BATTERY
ANTENNA
ANTENNA + BATTERY
ANTENNA
ANTENNA + BATTERY
ANTENNA
ANTENNA + BATTERY
ANTENNA + COM
ANTENNA + COM + BATTERY
ANTENNA + COM
ANTENNA + COM + BATTERY
ANTENNA + COM
ANTENNA + COM + BATTERY
ANTENNA + COM
ANTENNA + COM + BATTERY
In order to avoid possible damage, we recommend that you only use the
specified accessories.
These have been tested and shown to work well with this unit.
This device should be installed only by qualified personnel. Carefully read the
instruction manual in its entirety and keep it safe for future reference.
It is essential to know the information and comply with the instructions given in the
manual to ensure the fitting is installed, used and serviced correctly and safely.
Company identification: Manufacturer: Contrive, Srl
Via Enrico Fermi 18 24040 Suisio Italy
This unit is not authorised for use as critical component in life-support devices or
systems unless a specific written agreement has been given.
If incorrectly installed in a vehicle, the operation of GSM device could interfere with
the correct functioning of vehicle electronics. Verification of the protection of vehicle
electronics should form a part of the installation.
Regulations must be considered to operate a vehicle’s light or horn on public roads.
No complex software or hardware system is perfect.
Bugs are always present in a system of any size.
Brand:
Contrive
Equipment name: GsmComfort+ / GprsComfort+
Equipment type: GSM/GPRS modem
The GsmComfort+ is an industrial DIN rail GSM modem for the supervision and
control of remote HVAC devices by means of enhanced features available through
GSM network.
Industrial standard interface and an integrated SIM card reader mean it can be used
rapidly, easily and universally to quickly implement new applications in telemetry,
telematics and remote control. All interfaces are integrated in the housing.
The connections are suitable for use in domestic and industrial environments.
BUILT ON PROVEN TECHNOLOGY
Safety of information technnology equipment
Electromagnetic compatibility
ElectroMagnetic compatibility and Radio spectrum Matters
Specific conditions for mobile and portable radio and ancillary equipments
ElectroMagnetic compatibility measurement, control and laboratory use
Information technology equipment - Immunity characteristics
58
NOTE:
Radio spectrum matters
Class B equipment (domestic) emission level applied.
Class A equipment (industrial) immunity level applied.
EMCC DR. RAŠEK, GmbH
Moggast, Boelwiese 5
91320 Elbermannstadt Germany
90
71
and all tests were carried out
Notified Body:
S. GSM operation LED indicator
¡ OFF
No power supply
D
S
C
PERMANENTLY
¡ SLOW FLASH
200ms ON / 2s OFF
Module switched ON
Registered on the network
¡ QUICK FLASH
à
200ms ON / 600ms OFF
3 4 5 6 7 8 9 10 11 12 13 14
Module switched ON
Registered on the network
Communication in progress
B
1
This unit can be supplied either by alternating or direct current, polarity
independent. Power supply connection on terminal 1 and 2, top right side.
The power supply unit must meet the demands placed on SELV [1] circuits in
accordance with EN60950.
The power supply must not be shared with other equipment: suggested power
supply source is a simple 12VAC / 5VA transformer.
The maximum permissible connection length between device and supply source
is 3 m. Overvoltages are suppressed by internal varistor.
[1] Safety Extremely Low Voltage
ANTENNA
¡ ON
Module switched ON
Not registered on the network,
missing SIM or invalid PIN
HVAC
12 V DC ±20% polarity independent
12 V AC ±20%
< 30 mA @ 12 V DC in standby mode
< 100 mA @ 12 V DC in standby mode, relays ON
< 200 mA @ 12 V DC in communication mode
< 1 A @ 12 V DC max peak current
2
2 x 2.5 mm (AWG14) screw connector
2
AUX
GsmComfort+A
The embedded antenna is located under the front panel. This omnidirectional
antenna can work properly if the front side of the device is not shielded by metallic
frames (i.e.: the GsmComfort+A is installed inside a metal cabinet).
GsmComfort+X
An external dual-band antenna must be connected to the RF interface, implemented
as a 50W FME male coaxial jack at the end of a short RG174 cable stub exiting from
the top side of the device. The antenna must fulfil the requirements given below:
Frequency TX
880 to 915 MHz
1710 to 1785 MHz
Frequency RX
925 to 960 MHz
1805 to 1880 MHz
Impedance
VSWR
50 ohms
RX max
1.5 : 1
TX max
1.5 : 1
Polarization
Linear
Typical gain
0 dBi in one direction at least
We recommend a VSWR max of 1.5:1 although a VSWR max of 2:1 can be accepted
without affecting performance and certification. The DC impedance is floating but
there is no problem when using antennas that present a short to ground.
0678
Suisio, Italy February 21, 2006
CONTRIVE RESERVES THE RIGHT TO MODIFY THE CHARACTERISTICS STATED
IN THIS INSTRUCTION MANUAL AT ANY TIME AND WITHOUT PRIOR NOTICE.
© COPYRIGHT 2002...2005 CONTRIVE SRL ITALY. ALL RIGHTS RESERVED.
GsmSuite
®
TEMPERATURE SENSOR INPUT
Connect the specified temperature sensor between terminals 13-14.
Shielded cable should be used for long lines: shield must be connectedonly to
terminal 12, leave the probe side unconnected.
Probe type: NTC 10kohms @ 25°C ([email protected]÷85°C)
Probe current 100 uA
Probe voltage < 20VDC
Resolution 10 bits
Accuracy 2%
Sampling rate 90 Ksps/sec
Sampling time (filtered) 10 sec
2
2 x 2.5 mm (AWG14) screw connector
DIMENSIONS [mm]
PRODUCT FEATURES
Dual band EGSM900 and GSM1800 for data, sms, fax and voice applications
Full Type Approved and compliant with ETSI GSM Phase 2+
Output power:
Class 4 ( 2W @ 900 MHz )
Class 1 ( 1W @ 1800 MHz )
Temperature:
operating -20 to 55°C
storage and transport –30 to 85°C
Relative humidity:
operating 5 to 95% non-condensing
storage & transport 5 to 95% condensation allowed outside
Enclosure:
EN-50022 rail 4 modules, polycarbonate, UL94 -V0
Overall dimensions: mm 71 x 90 x 58 ( W x H x D )
Weight:
200 g
Degree of protection: IP 40 (EN-60529 / IEC 529) properly fitted
Contact voltage < 20 VDC
Contact current < 2 mA
2
2 x 2.5 mm (AWG14) screw connector
OUTPUTS
An SPDT contact is available to control the heating or cooling machine. This could
be a circulation pump, an electrovalve or any electrical device.
Terminal 4 is the contact common, terminal 5 is the normally closed contact and
terminal 6 the normally open contact.
An SPDT contact is available to control any user load.
Terminal 7 is the contact common, terminal 8 is the normally closed contact and
terminal 9 the normally open contact.
Rated current 4 A
Rated voltage 250 Vac
Max breaking capacity 2500 VA
Minimum contact load 100 mA, 12 V
Cadmium free contacts
Insulation 250 V (IEC60664 / VDE0110b - cat. III / C)
Surge voltage coil contacts: 4000VRMS
Dielectric strength coil-contacts 2500VRMS
open contact circuit 1000VRMS
2
4 x 2.5 mm (AWG14) screw connector
®
Using the free software GsmSuite for PC running Microsoft Windows it’s
possible to manage advanced configuration, control, tracing and other features
either in local or remote mode.
DEVICES WITH COM PORT [P]
Remove the front cover following the instructions to access the RJ45 8 pin
modular jack serial interface [P].
Link cable 1013.00.02 is available from local resellers.
1 2
õ
AUX INPUT
SPST contacts can be connected between terminals 11-12, power supply for
contact is provided by GsmComfort+.
Using electronic switches, terminal 11 is the positive legs.
In order to avoid false triggering, contact will be considered closed or open after
10÷20 seconds from stable condition.
Front panel red led indicator [C] will lit when link is open.
¡ Measures for the efficient use of the radio frequency spectrum clause 3.2:
EN 300 607
X. External antenna (type X only)
RG174 + FME male jack
Contrive disclaims all liability for damage to the fitting or to other property or persons
deriving from installation, use and maintenance that have not been carried out in
conformity with this instruction manual, which must always accompany the fitting.
GSM900/1800 essential requirements for mobile stations
¡ Protection requirements concerning EMC clause 3.1b:
EN 61326
EN 55024
1 2
All units are 100% functionally tested. Specifications are based on characterisation
of tested sample units rather than testing over temperature and voltage each unit.
¡ Health and safety requirements pursuant to clause 3.1a:
EN 301 489-1
EN 301 489-7
D. Output green led status indicators
INPUTS / OUTPUTS
In order to prevent danger to life or property, it is the responsibility of the system
designer to incorporate redundant protective mechanism appropriate to the risk
involved.
We declare on our sole responsibility, that the product described above
is in compliance with the essential requirements of the 1999/5/CE Directive:
EN 60950-1
A
Power supply:
PRODUCT DESCRIPTION
R&TTE Directive 1999/5/EC
EN 301 511
C. Input red led status indicators
This RF unit is not designed for and intended to be used in portable applications
(within 20 cm or 8 inches of the body of the user) and such uses are strictly prohibited.
DECLARATION OF CONFORMITY
Product identification:
õ
B. Input and output terminals
14 x 2,5mm2 (AWG14)
POWER SUPPLY
P
3 4 5 6 7 8 9 10 1112 13 14
Communication:
RJ45 PINOUT
1
8
1. GND
2. RTS
3. GND
4. CTS
5. GND
6. TxD
7. GND
8. RxD
DB9-5
DB9-7
DB9-8
DB9-3
DB9-2
RS-232 (DCE)
300 ... 115200 bit/s
7/8 data bits, 1/2 stop bits, 1 parity bit, 10/11 bit char length
Software handshake, Hardware handshake
ALL DEVICES
It’s possible to use GsmSuite to handle simple remote management by means of
any device having SMS issuing capabilities (a mobile phone or Internet service).
A GSM modem driven by GsmSuite can give you professional remote control.
PC running
GsmSuite
GSM modem
(GsmTerminal+)
REMOTE
UNIT
®
®
Configuration software GsmSuite for PC running Microsoft Windows and technical
literature are available for free download at www.gsm-control.biz .
SIM CARD
ACCESS INSIDE
2
The SIM card receptacle is intended for 3V SIM cards [GSM 11.12 phase 2+].
The SIM card must be inserted in the cardholder to put the unit into operation.
Make sure that there is no voltage applied to GsmComfort+.
Disconnect also the backup battery, if any. Following the figure below:
1
1. Unlock the top cover using
a small screwdriver.
2. Slide up the top lid.
2
Serial communication port and
optional backup battery are located
inside the unit.
If the unit is provided with UPS
feature, a backup battery can be
installed to keep the device
working even during power failures.
Once the front cover has been
removed:
Before to open the unit disconnect
power supply and all live circuits
that may be connected.
2
The front cover must be removed to
access the inside of the unit :
1
3. Insert the SIM card in the
receptacle, contacts must be
on the bottom side.
1
BACKUP BATTERY
1
1. Push with two fingers on
top and bottom sides of
front cover to release it.
2. Pull the front cover and
keep it in a safe place.
To remove the SIM
card repeat operations
1 and 2, gently pull the
SIM card out.
1. Clip the battery to available
connector. This connector
must be isolated when
operating without backup
battery.
3
2. Push the battery into
retainer lids located under
front cover.
3. Replace the front cover to
close the unit.
WHEN USING BATTERIES AND
ACCUMULATORS ADHERE TO
RELEVANT REGULATIONS
3
Do not operate without top cover, once the
SIM card has been inserted replace the top
lid and then connect power supply.
The newer NiMH batteries are less harmful to the environment, have a longer life,
and contain recyclable materials. Recycling options available in your local area
should be considered when disposing of this product. Do not dispose of in fire.
SIM PIN
Operating without SIM PIN
The simplest way is to put your SIM card into a cellular phone and
program it so it won't ask for the PIN. The SIM card is 'open' and
someone could steal the SIM card, use it and read the information inside.
Enter default SIM PIN
GsmComfort+ comes with a default PIN = 0000 (four zeroes).
Put your SIM card into a cellular phone and program the PIN using the
given number.
Change default SIM PIN
Using com port and GsmSuite running on Microsoft® Windows®
PC you can modify the default PIN on both GsmComfort+ and SIM card.
WARNING
If you insert a SIM card that asks for a PIN number different from
that stored into GsmComfort+, the device will not operate.
If you enter the PIN 3 times incorrectly, SIM card will lock up and you
must provide the PUK (PIN Unblocking Key).
STATUS SMS
To improve the readability of information sent by this device it’s suitable to provide
some specific information: a supervisor can issue the following SMS:
+3,300,tel,info,,,,,email,text
Following a typical status SMS issued on request:
Building 1
Short description
Apt. 5 living room
Detailed device application info
Temp:20 C
measured temperature -EEE / 1÷40°C / +EEE
Out : off
hvac output (1) status
remaining time to reg off
Reg :heat, 22 C, 5 C, 00:00:05
AuxO:on 14/09/06,21:10:00
date/time of out release
AuxI:open
aux input status
Mode:toggle on
clip mode and activation status
Blackout
Main power failure detected
tel
info
email
text
start character
system PIN (default = 0000)
supervisor’s name to be stored
optional email address
end character
20 CHAR MAX
14 CHAR MAX
40 CHAR MAX
56 CHAR MAX
[1]
[2]
Example: +3,300,+4456789,Building 1,,,,,,Apt. 5 living room
info and text will be shown within status SMS sent by this unit.
Out status:
[1] Device phone number (always in international format) will be used to perform
real time clock autosync, missing this field the real time clock is unreliable and
SMS commands involving date field will be rejected.
[2] All email issued from Gprs type unit will be sent carbon copy also to its own
mailbox if a a valid address is provided.
SMS CONTROL
Store first supervisor
Although it is not mandatory to store a supervisor, you may add a supervisor who
then has additional special commands only available to him (advanced manual).
To store the first supervisor, once the unit is operative, issue the following SMS:
#xxxx.Name.email*
#
xxxx
Name
email
*
Device own phone number
Short description
Optional device own email address
Detailed device application info
4 CHARACTERS
14 CHARACTERS MAX
40 CHARACTERS MAX
Example: #0000.Harry [email protected]*
The telephone number of SMS sender is automatically collected from the
incoming call presentation (thus the telephone number must be kept visible) and
will be assumed as the first supervisor’s telephone number.
First supervisor will be stored at position 401 and the unit will send back a
confirmation or error SMS.
Dots are allowed ONLY within the email address field.
It’s possible to use both ? and @ characters before the domain name.
SMS delivery failure is usually less than 1% but you must keep in mind
that a message could not arrive and you cannot complain with your
operator for this. GsmComfort+ deletes any pending SMS at power-on.
Any registered user can control outputs by means of SMS.
Following default commands can be changed to any custom text using GsmSuite.
More details available on “Advanced Manual”.
on
off
run
S
R
M
D
B
Enable regulation to reach setpoint (if any)
Disable regulation (antifrost active in heat mode)
Enable regulation to reach setpoint (if any) until specified date
Set Aux output ON
Reset Aux output OFF
Set Aux output ON and LATCH (set again at further power on)
Status SMS request
Ringback request once massage has been processed
[3]
[4]
[3]
[4]
Commands will be recognized both uppercase, lowercase and mixed, nested
within other text wherever placed inside the incoming SMS.
Multiple commands into same SMS are allowed. An operator registered both like
user and supervisor can issue SMS made by control and system commands.
[3]
[4]
Specifying a time interval after the set command, outputs will be released
once set time has elapsed. If a power failure occurs, the remainig time is
missing, thus the output will be released. Commad syntax:
onddhhmm
dd
days
00 - 99
hh
hours
00 - 23
mm
minutes 00 - 59
Specifying date/time after the set and latch command, outputs will be
released at specified expiry date/time. Output status will be recovered after
blackout providing the real time clock sync has been performed successfully.
offddmmyyhhmm
dd
day
01 ÷31
hh
month
01 ÷ 12
hh
year
00 ÷ 99
hh
hours
00 ÷ 23
mm
minutes 00 ÷ 59
Example: on020830 M2504061230 text D alien trailer
turn ON regulation for 2 days 8 hours and 30 minutes,
turn on and latch output 2 until April 25, 2006 12:30
send back a status SMS
Setpoint=22 on
enter new setpoint temperature (supervisor command)
and activate regulation (user command)
off
on
Aux Out status: off
on
!on
Aux In status: open
close
off
Reg status:
antifrost
heat
cool
Your GsmComfort is the product of advanced engineering, design and craftmanship
and should be treated with care. The suggestion below will help you to enjoy this
product for many years.
¡ Do not expose the unit to temperature or humidity out of operating range.
¡ Do not use or store the unit in dusty or dirty areas, moving parts can be damaged.
¡ Do not use chemical cleaning agent on the unit or the SIM card.
¡ Do not attempt to disassemble the unit. This device is not user serviceable.
¡ Do not expose the unit to water, rain or spilt beverages. It is not waterproof.
¡ Do not abuse the unit by dropping, knocking or violenty shaking it.
¡ Do not place the unit alongside computer discs, credit or travel cards or other
magnetic media. The information contained on these devices may be affected.
¡ This unit is under your responsibility. Please treat it with care respecting all local
regulations. It is not a toy: keep it in a safe place and out of the reach of children.
¡ Treat the SIM card with the same care as your credit card: do not bend or scratch
or expose it to static electricity.
¡ Try to remember your unlock and PIN codes. Become familiar with and use the
security features to block unautorised use and theft.
Both fixed and mobile applications are allowed, as defined below:
Fixed means that the device is physically secured at one location and is not able
to be easily moved to another location.
Mobile means that the device is designed to be used in other than fixed locations
and generally in such a way that a separation distance of at least 20 cm (8 inches)
is normally maintained between the transmitter’s antenna and the body of the user
or nearby persons.
Do contact an authorized service center in the unlikely event of a fault in the unit.
SYSTEM COMMANDS
DEVICE INFO
QUICK START
Add Users (group 0)
Remote control is allowed to registered users only.
It's possible to add, modify or delete subscribers
from the SIM card phonebook using any GSM
mobile phone or SIM card reader/writer.
Following operating instructions provided by
phone manufacturer insert the SIM card into the
SIM card holder, turn on the phone and scroll the
option menu to enter the SIM card Phonebook edit
mode.
Enter the users name and telephone number using international format.
Insert the SIM card into the device SIM card holder and turn on the power supply,
the unit is ready to operate.
Use only NiMH rechargeable
batteries 8.4V or 9.6V type.
CARE AND MAINTENANCE
relay off (regulation off or setpoint reached)
relay on (regulation on, setpoint unreached)
out released, inactive
out active
out active and latched
input open, inactive
input close, active
regulation off
antifrost protection running
regulation active in heat mode
regulation active in cool mode
FREE CLIP CONTROL
Incoming voice (or fax) calls from registered users will toggle regulation on to off or
vice-versa. A ringback will be issued only when enabling the regulation.
If the user waits online, after 15” GsmComfort+ will answer, playing a low tone when
output was released or four high tones after output activation. No ringback will be
issued in such case. Regulation status is recovered after blackouts.
REGULATION
The comfort setpoint can be modified by supervisors issuing the following SMS:
Setpoint=xx
XX = TEMPERATURE TO REACH
Once regulation is enabled output 1 will be activated until setpoint is reached.
To operate in pure on/off mode, without setpoint, set comfort temperature to 0.
In such case the output will stay on until next off request.
GsmComfort+ can operate in heat or cool mode. Operating in heat mode an antifrost
protection is active, turning on output 1 when temperature is below safe limit (5°C).
To disable antifrost protection set antifrost temperature to 0.
Special control SMS are reserved for supervisors only:
Stop
Disable free calls control feature (CLIP): incoming calls will be rejected.
Start
Enable free calls control feature (CLIP): incoming calls from registered users will
activate outputs following the specified sequence.
Lista#
An SMS reporting last # (1-9) answered call list will be sent. Full list specifying 0.
Listu#
An SMS reporting last # (1-9) unanswered call list will be sent. 0 = full list.
Pbook
An Email reporting the complete phonebook will be issued to supervisor’s email
address, if any (GPRS only).
Pbook++
An Email reporting the complete phonebook and all system settings will be issued
to supervisor’s email address, if any (GPRS only).
ADVANCED CONFIGURATION
Using GsmSuite is possible to configure advanced features, either linking the unit
with local com port or issuing SMS in remote mode. Refer to GsmSuite help file or
Advanced Manual for detailed information. Most important advanced features:
Add / edit Recipients (group 9)
Alerts following local events can be issued to Recipients (up to 100).
Add / edit Supervisors (group 7)
Up to 100 supervisors can be stored inside the unit.
Add / edit Users (group 0 / group 1)
Users can be stored into SIM card phonebook.
Conditional users (having more features) can be stored into device memory.
Delete Phonebook entries
Remove any entry from phonebooks by means of GsmSuite or issuing an SMS.
GPRS / Email settings
Emails service configuration, available for GPRS devices.
Scheduled operations
Activities to be performed on a time basis (up to 100).
Regulation malfunction
If the setpoint is not reached within the limit time (4 hours default) GsmComfort+
will issue alert SMS to defined recipients (ref. “Advanced Manual”).
THE INFORMATION CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE
WITHOUT NOTICE. PRODUCT NAMES, CORPORATE NAMES OR TITLES USED WITHIN
THIS DOCUMENT MAY BE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER
COMPANIES AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE
READERS’ BENEFIT, AND WITHOUT INTENTION TO INFRINGE.
Change regulation settings
Default regulation settings can be changed by supervisors issuing an SMS:
+6,289,,Temp,set,frost,mode,trend,unit
WHILE EVERY EFFORT HAS BEEN MADE TO MAKE SURE THE INFORMATION IN THIS
DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES
WHATSOEVER FOR LOSS RELATING TO THIS DOCUMENT.
Temp
set
frost
mode
trend
unit
Fixed test identifying entry type
Setpoint temperature
2÷99
Antifrost temperature
2÷99
1=heat / 0 = cool
reaction time alarm (hours) 1÷12
Celsius / Fahrenheit
WARRANTIES
DEFAULT = 20°C
DEFAULT = 5°C
DEFAULT = 1
DEFAULT = 4
DEFAULT = C
Example: +6,289,,Temp,24,0,1,2,F
to set heat mode, comfort temperature 72 (same as setpoint=72)
disable antifrost protection, reaction time within 2 hours, Fahrenheit
CONTRIVE GUARANTEES FOR TWO YEARS FROM THE DATE OF MANUFACTURE OF
ITS PRODUCT TO REPLACE, OR, AT ITS OPTION, TO REPAIR ANY PRODUCT OR PART
THEREOF WHICH IS FOUND DEFECTIVE IN MATERIAL OR WORKMANSHIP OR WHICH
OTHERWISE FAILS TO CONFORM TO THE DESCRIPTION OF ITS SALES ORDER.
CONTRIVE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER
WARRANTY EXPRESS OR IMPLIED. IN NO EVENT SHALL CONTRIVE BE LIABLE FOR
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE WHICH MAY ARISE IN
CONNECTION WITH SUCH PRODUCTS.
THE WARRANTY DOES NOT APPLY IN CASE OF IMPROPER USE
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement