Model: PRT-W
FAQ
Wireless Series
Model: PRT-W
Model: PRT-W
Model: PRT-W
Table of Contents
Product Image
Table of Contents
What is a Programmable
Room Thermostat?
Installation Procedure
Installing the Batteries
Replacing the Batteries
Pairing with the RC1-W Receiver
Pairing the Thermostat
Pairing with the UH1-W
Wiring Centre
LCD Display
Setting the Clock
Temperature Display
Setting the Comfort levels
Locking the Thermostat
Setting the Temperature
Temperature Hold
1
2
3-4
11-12
13-14
15
16
17-18
19
20
21
5-6
7-8
9
10
11
Holiday Programming
Frost Protection
Power ON / OFF
Optional Features
Re-calibrating the Thermostat
Factory Reset
Wiring Diagram
22
23
24
25-28
29
29
30
1
2
What is a Programmable Room Thermostat?
A programmable room thermostat is both a programmer and a room thermostat.
The programmer allows you to set “On” and “Off” periods to suit your own lifestyle.
The room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
So a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs and preferences.
Setting a room thermostat to a higher temperature will not make the room heat up any faster. How quickly the room heats up depends on the design & size of the heating system.
Similarly reducing the temperature setting does not affect how quickly the room cools down. Setting a programmable room thermostat to a lower temperature will result in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job.
3 Wireless Series
The best way to do this is to set the room thermostat to a low temperature
– say 18°C , and then turn it up by 1°C each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves
(TRVs) on individual radiators.
If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
You are able to temporarily adjust the heating program by overriding or using the temperature hold feature. These features are explained further on pages 14 and 15 of this manual.
Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may also prevent the thermostat from working properly.
Model: PRT-W
4
Installation Procedure
Do
Mount the thermostat at eye level.
Read the instructions fully so you get the best from our product.
Don’t
Do not install near to a direct heat source as this will affect functionality.
Do not push hard on the LCD screen as this may cause irreparable damage.
This wireless thermostat is designed to be surface mounted.
Step 1
Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat.
Step 2
If you are installing a remote air temperature probe, terminate the thermostat as shown in the diagram on page 30.
Mark 2 hole positions on the wall using the backplate as a positioning template.
Drill at the marked positions and insert a wall plug into each hole.
Step 3
Screw the thermostat back plate securely on the wall.
Step 4
Clip the front of the thermostat back onto the thermostat back plate.
5 Wireless Series
Installing the Batteries
2x AAA batteries have been supplied with this thermostat.
To access the battery holder, push and release the compartment door located on the bottom face of the thermostat.
1
3
2
4
Model: PRT-W
6
7 Wireless Series
Replacing the Batteries
Batteries have a fixed lifespan and will need to be replaced occasionally to ensure the thermostat operates correctly.
The thermostat will inform you when the batteries need to be replaced by displaying the battery icon on screen.
Note: You must replace the batteries within 1 minute of removal in order to retain the current clock and comfort level settings.
9 Wireless Series
Battery Icon
(Flashes)
Insert the batteries in the empty battery holder, ensuring that each battery is orientated for the correct polarity + / - .
Push the battery holder back inside the thermostat until it is secured in its closed position.
Model: PRT-W
8
•
•
•
•
•
•
•
•
•
Pairing With the RC1-W Receiver
If using with the UH1-W wiring centre, turn to page 11.
With the thermostat turned OFF:
•
•
Press & hold the Clock button until you see two sets of numbers appear ...
The small number 01 in the top right corner of the LCD is the feature number.
Press Clock repeatedly until you see feature 06 (Receiver Type) ......................
The options within feature 06 are: 00 = UH1-W or 01 = RC1-W receiver.
Use the Up/Down keys to set feature 06 to 01 (RC1-W) .............................
Press Clock again until you see feature 07 (Receiver Address) .........................
You can now select a Receiver Address from 01-32.
Use the Up/Down keys to set feature 07 to 01 ...............................................
(You must set a unique receiver address for each receiver installed).
Press Clock again until you see feature 08 (Zone number) ................................
You are able to connect two PRT-W thermostats to one RC1-W receiver.
Use the Up/Down keys to select the zone this thermostat controls (01 or 02) ....................................................................................................
Press A to confirm settings and the display will go blank ..................................
Model: PRT-W
10
Pairing the Thermostat
•
•
•
•
On the receiver, press and hold the Pairing button until the Comms LED lights up.
With the thermostat turned OFF, press & hold the A button for 5 seconds ...........
The thermostat will send a signal for 1 minute and will flash the RF signal icon ...
If pairing is successful, the Comms LED on the receiver will flash.
• Press the Power button on the thermostat once to confirm pairing ........................
If pairing is unsuccessful, check features 06 to 08 have been configured correctly.
To eliminate a possible signal issue, reposition the thermostat closer to the receiver and repeat the pairing process again.
Pairing With the UH1-W Wiring Centre
•
•
On the UH1-W wiring centre, take note of the number set on the rotary switch
(Board ID number 1-9).
Each UH1-W on the system needs to have a different ID number.
With the thermostat turned OFF:
Press & hold the Clock button until 2 sets of numbers appear on screen ..............
The small number 01 in the top right corner of the LCD is the feature number.
11 Wireless Series
1 2 3 4 5 6
•
•
•
•
•
•
•
•
•
•
•
Press Clock repeatedly until you see feature 06 (Receiver Type) .......................
The options within feature 06 are: 00 = UH1-W or 01 = RC1-W receiver.
Use the Up/Down keys to set feature 06 to 00 (UH1-W) ..............................
Press Clock again until you see feature 07 (UH1-W Board Address) ................
Use the Up/Down keys to set the large digits to the board address of the UH1-W. This is the number set on the UH1-W rotary switch...
(You must set a unique board address for each UH1-W installed).
Press Clock again until you see feature 08 (Zone number, 01-08) ....................
The UH1-W is an 8 zone receiver.
Use the Up/Down buttons to select the zone this thermostat should be linked to ....................................................................................................
Press Clock again until you see feature 09 .................................................................
(00 = Underfloor heating, 01 = Radiators.)
Use the Up/Down buttons to specify whether the thermostat is controlling underfloor heating or radiators .....................................................
Press A to confirm settings and the display will go blank ....................................
Press the Power button once to turn the thermostat back ON .........................
Press the Up key to set the target temperature above the room temperature; the flame symbol will appear and the assigned zone on the UH1-W will be activated ..........................................................................
This indicates pairing between the thermostat and the UH1-W is successful.
Model: PRT-W
12
14
LCD Display
1. Room Temp - Indicates the current temperature sensor mode.
2. Day Indicator - Displays the current day.
3. Frost Icon - Displayed when the thermostat is in frost protection mode.
4. Flame Icon - Displayed when the thermostat is calling for heat, flashes when the
Optimum Start function is in operation.
5. RF Icon - Flashes when the thermostat communicates with the receiver.
6. Temperature Hold - Displayed when manually overriding the program, “HOLD
FOR” and the time period are displayed.
7. Set - Displayed when changes are made to programs or temperature set points.
8. Holiday Indicator - Displayed when the programmer is in holiday mode.
9. Current Temp - Indicates the current sensor temperature.
10. Program Cycle Indicator - Displayed during programming only to show which period is being altered.
11. Battery Level - Indicates when the batteries require replacement.
12. Keypad Lock Indicator - Displayed when the keypad is locked.
13. Units of Temperature - Degrees Celsius or Fahrenheit.
14. Clock - Digital clock display in 24h format.
7
13
8 9 10
Wireless Series
11 12 13
Model: PRT-W
14
Setting the Clock
To set the clock, follow these steps.
• With the thermostat turned ON, press the Clock key twice .................................
• Use the Up/Down keys to set the hours ..............................................................
• Press H to confirm settings ................................................................................................
• Use the Up/Down keys to set the minutes .........................................................
• Press H to confirm settings ...............................................................................................
• Use the Up/Down keys to set the day of the week ..........................................
• Press A to confirm settings and return to main display ..........................................
Day
Hours
Minutes
Temperature Display
The temperature display information is driven by two different inputs; the sensor measurement and the target temperature you have set.
Room Temperature Set Temperature
This is the current room temperature.
This is the temperature you are trying to achieve in your home.
15 Wireless Series
Model: PRT-W
16
Comfort Levels Explained
The thermostat provides Weekday/Weekend or 7 Day Programming options.
You should consult the “Optional Features” section to select the required mode.
The thermostat is supplied with comfort levels already programmed, but these can be changed easily. The default times and temperatures are;
08.00 - 21°C (Wake) 09.30 - 16°C (Leave) 16.30 - 22°C (Return) 23.00 - 17°C (Sleep)
If you only want to use 2 levels, you should program the unused levels to
--.--
Note: For Weekday/Weekend programming, the 4 comfort levels are the same for all weekdays but can be different for the weekends.
For 7 Day programming, each day can have 4 different comfort levels.
• To program comfort levels, press Clock once ...................................................................
• Use the Up/Down keys to enter the required WAKE time .......................
• Press H to confirm settings ..........................................................................................
• Use the Up/Down keys to enter the required WAKE temperature .......
• Press H to confirm settings ..........................................................................................
• You will now see “LEAVE” displayed on screen.
• Repeat the programming steps for each period until complete.
• For unused periods enter --.-- and the thermostat will ignore the setting.
• Press A to confirm settings and return to main display ....................................
Note:
• In 7 Day programming mode you can repeat for each day independently.
• In Weekday/Weekend programming mode you will see Sat Sun displayed on screen and can repeat for the weekend.
• To change the programming mode please refer to pages 20-22.
17
For Weekday/Weekend programming,
Mon Tue Wed Thu Fri are displayed on screen.
For 7 Day programming, only Mon is displayed in the day indicator field.
Wireless Series
Locking the Thermostat
The thermostat has a keypad lock facility. To activate the lock follow these steps.
• Press and hold the A and Down keys together for 10 seconds ..........
• You will see the lock symbol appear on screen .............................................
• To unlock, repeat the steps above until the lock symbol disappears.
Note: The keypad lock indicator is only displayed when the lock is active.
Model: PRT-W
Temperature Control
The Up/Down keys allow you to adjust the set temperature .......................
When you press either key, you will see the word SET and the desired temperature will be displayed on screen.
Use the Up/Down keys to adjust the SET value ..................................................
Press A to confirm settings and return to main display .............................................
Note: This override will be maintained until the next programmed comfort level.
18
Set Temperature
Set Icon
Keypad Lock Indicator
19 Wireless Series
Model: PRT-W
20
Temperature Hold
The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period.
• Press H to commence temperature hold ...................................................................
• Use the Up/Down keys to enter the required Hold time..............................
• Press H to confirm settings ..............................................................................................
• Use the Up/Down keys to enter the required Hold temperature..............
• Press A to confirm settings and return to main display ........................................
You will see the Hold indication is displayed on screen.
The time will countdown the set duration and then revert to the normal program.
Holiday
The holiday function allows you to quickly enter a holiday setting. During a holiday, the thermostat will maintain the frost set temperature. At the end of your holiday, the thermostat will revert back to the programmed setting ensuring that your home is warm on your arrival.
• Press H three times (until you see the suitcase on screen) ...................................
• Use the Up/Down keys to enter the number of days holiday ....................
• Press A to confirm settings and return to main display ........................................
The display will show a suitcase indicating the thermostat is in holiday mode.
Note: A holiday period does not start until 00:00 the next day. For example, if you set a holiday period on Friday for 2 days, Saturday will be counted as the first day and the thermostat will revert back to the programmed schedule at 00:00 on Monday.
Hold ON Indicator
Hold Time Remaining
Holiday Days
To cancel temperature hold, follow the same steps but reduce the Hold time to 00:00 hours.
21 Wireless Series
Holiday ON Indicator
To cancel, follow the same steps but reduce the Holiday duration to 00 days.
Model: PRT-W
22
Frost Mode
Pressing the Power button once will place the thermostat in frost protect mode.
In this mode, the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature (see page 19).
Should the heating be turned on whilst in frost mode, the flame icon will be displayed.
To cancel the frost protect mode, press the Power button once again.
Frost Protection Mode Enabled
Heating On/Off
The heating is indicated ON when the flame icon is displayed.
When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the thermostat remains active.
To turn the thermostat OFF completely, press and hold the Power button..........
The display and heating output will be turned OFF completely.*
To turn the thermostat back ON, press the Power button once again ...................
Thermostat completely OFF Thermostat powered ON
*See Feature 3 on page 25
23 Wireless Series
Adjusting the Optional Settings
To adjust the optional settings, follow these steps.
• Press and hold the Power button to turn the thermostat OFF ..............................
• Press and hold the Clock key until the display appears as shown below ..........
Setting Value
Feature Number
• Use the Clock key to cycle through the features ......................................................
• Use the Up/Down keys to change the setting ....................................................
• Press A to confirm settings .................................................................................................
• Press the Power button once again to turn the thermostat back ON .................
27 Wireless Series
Model: PRT-W
24
Optional Features Explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED
Feature 01 - Temperature Format: This function allows you to select between °C and °F.
Feature 02 – Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 1°C which means that with a set temperature of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C. With a 2°C differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 – Frost Protect: You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off. As a default, this is enabled.
Feature 04 – Frost Protect Temperature: This is the temperature maintained when the thermostat is in frost mode. The range is 07-17°C. The default is 12°C and is suitable for most applications.
Feature 05 – Output Delay: To prevent rapid switching, and output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 06 – UH1-W or RC1-W receiver: The thermostat can work with our UH1-W 8 zone wiring centre or RC1-W 2 channel receiver. This setting determines which is being used.
Feature 07 – Receiver Address: Within one building, up to 9 UH1-W’s or 32 RC1-W’s can be used. Each receiver must have a unique receiver address.
Feature 08 – Zone Number: This is the zone number you are assigning the thermostat to on either the UH1-W or the RC1-W receiver. 01 - 08 - UH1-W, 01 - 02 – RC1-W
25 Wireless Series
Feature 09 – Underfloor Heating or Radiator Zone (UH1-W Only):
This setting determines whether the thermostat will activate the pump & boiler output on the UH1-W. If set to 00 the outputs will be activated. 00 = UFH, 01 = Radiators
Feature 10 – Fail Safe If enabled, the thermostat will send a signal to the receiver every
20 minutes. Should the receiver fail to receive two signals, the receiver will activate the output for 20% of the time. This is to protect the system against a loss of wireless signal and in case the thermostat battery fails whilst you are away.
Feature 11 – Up/Down Temperature Limit: This function allows you to limit the use of the up and down keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control of the heating system.
Feature 12 – Air Sensor Selection: On this thermostat, you can select which sensor should be used - built in sensor or remote air sensor.
Feature 13 – Not used on this model
Feature 14 – Optimum Start: Optimum start will delay the start up of the heating system to the latest possible moment to avoid unnecessary heating and ensure the building is warm at the programmed time. The thermostat uses the rate of change information to calculate how long the heating needs to raise the building temperature
1°C (with a rate of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1°C) and starts the heating accordingly.
Feature 15 - Rate of Change: For information only.
Feature 16 - Programming Mode: The thermostat offers two programming methods.
Weekday/Weekend allows you to program 4 comfort levels for the weekdays and 4 different comfort levels for the weekend. In 7 day program mode, each day has 4 comfort levels that can be programmed independently.
Model: PRT-W
26
14
15
16
10
11
12
13
FEATURE
01
02
03
04
05
06
07
08
09
Optional Settings - Feature Table
DESCRIPTION
Temperature Format
Switching Differential
Frost Mode
Frost Protection Temperature
Output Delay
UH1-W or RC1-W Receiver
Receiver Board Address
Zone Number
Underfloor Heating or Radiator
(UH1-W Only)
Fail Safe
Up/Down Limit
Sensor Selection
Not Used
Preheat Setting
Rate of Change
5/2 Day or 7 Day Programming
SETTING
00 = o C, 01 = o F (°C = Default)
01 o - 03 o C (01 o C = Default)
00 = Disabled, 01 = Enabled (01 = Default)
07 o - 17 o C (12 o C = Default)
00 - 15 Minutes (00 = Default)
00 = UH1-W, 01 = RC1-W (00 = Default)
UH1-W = 01-09, RC1-W = 01-32, (00 = Default)
UH1-W - 01-08, RC1-W = 01-02
Underfloor Heating = 00, Radiator Zone = 01
00 Disabled, 01 Enabled (01 = Default)
00-10 o C (00 o C = Default)
00 = Built In Sensor, 01 = Remote Air Sensor
Not Used
00-03 hours (00 = default)
Minute to raise 1 o C
00 = 5/2 day, 01 = 7 day (00 = default)
Model: PRT-W
28
Re-calibrating the Thermostat
If you need to re-calibrate the thermostat, follow these steps.
• Press and hold the Power button to turn the thermostat OFF ............................
• Press and hold BOTH the Power and Down keys together until the temperature appears on the screen ........................................................................
• Use the Up/Down keys to configure the new temperature ...........................
• Press A to confirm settings ...............................................................................................
• Press the Power button once to turn the thermostat back ON ..........................
Factory Reset
The thermostat has a reset function to restore all settings to their factory defaults.
To perform a factory reset, follow these steps.
• Press and hold the Power button to turn the thermostat OFF ..........................
• Press and hold the Power and Up keys together until the LCD powers up.
All of the icons will be displayed on screen .........................................................
• When the icons have disappeared from the screen, the thermostat has been successfully reset.
• Press the Power button once to turn the thermostat back ON .........................
29 Wireless Series
Wiring Diagram - Remote Air Sensor
REMOTE AIR PROBE
Set feature 12 to 01 to enable the remote air probe
Red
Wire
White
Wire
Model: PRT-W
30