Measuring Instruments and Testers 2006
Measuring Instruments
and Testers 2006
Certificates, Internet
Direct link
Measuring and Test Technology:
www.gossenmetrawatt.com
• Product descriptions for our instruments with illustrations
including accessories and related software
• Comprehensive product data sheets in
PDF format for printing or download
• Services including:
Initial start-up and queries, updates,
replacement parts, repairs and maintenance,
used measuring instruments, bargain market,
rental instruments and disposal of old instruments,
calibrating and test services,
tests per BGV A3 (VBG4)
• Training and seminars with practical experience
• Forum: applications reports and special features
on subjects of interest
• Requests for information
• News and press reports
• Contact addresses inside and outside of Germany
tion laboratory
Our DKD calibra rdance with
acco
is accredited in ISO/IEC 17025
DIN
d recalibration
Calibration an
d
of our own an
other devices:
2
Made in Germany
Table of Contents
General
Facility Management Solution
Universal Measuring and Recording
Photometry
Power - Energy - Voltage Quality
Electrical Testing
Clip-On Meters, Voltage Testers
Cable Detection System
Safety Standard IEC 61010-1
Power Supplies
Energy Management
Appendix
Made in Germany
Certificates, Internet
New Products
Recommended Workshop Equipment
Modular Test System
Accessories for Modular Test System
METRA Hit Series Multimeter Overview
Handheld Digital Multimeters
Hand-Held Digital Multimeters with Insulation Tester
Analog-Digital, Handheld Analog Multimeters
Handheld Analog Multimeters
Folding Digital/Analog Multimeters
Resistance Measuring Instruments and Insulation Tester
AS-i Bus Testers
Accessories and Software for AS-i Bus Testers
Calibrators
Power Meters
Multimeter Accessories: Fuses – Consumable Materials, Pouches, Cases, etc.
Multimeter Accessories – Overview
Multimeter Accessories
Multimeter Accessories: Interface Adapters, Memory Adapters
Software for Measuring Instruments
Software for Calibrators
Illuminance Meters
Luminance Meters
Energy and Power Disturbance Analyzer
Accessories for Power Disturbance Analyzer
Voltage Quality Analyzers
Software for Voltage Quality Analyzers
Test Instruments – VDE 0100 / IEC 364-6-61
Testers – DIN VDE 0100 / IEC 364-6-61: Add-Ons
Testers – DIN VDE 0100 / IEC 364-6-61: Accessories
Test Instruments – VDE 0100 / IEC 364-6-61
Testers – EN 60204/DIN VDE 0113
Testers – DIN VDE 0701/0702
Testers – DIN VDE 0701/0702/0751
Testers – DIN VDE 0701/0702/0751 / IEC EN 60601/60335/60950/61010
Testers – DIN VDE 0701/0702, Test Instrument Accessories
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
Earth Testers – DIN VDE 0413/EN 61557-1/-5
Accessories for Earth Testers – DIN VDE 0413/EN 61557-1/-5
Phase Sequence Indicators – EN 61557-1/-7
Test Instrument Accessories
Test Instrument Accessories – Overview
Software for Test Instruments
Workshop Test Panels – VDE 0104
Clip-On Meters
Voltage Testers, Cable Detection System
The New IEC 61010-1 Safety Standard
Power Supply Overview
Computer Controlled Laboratory Power Supplies
Computer Controlled Laboratory Power Supplies, Soft Front-Panel
Analog Controlled Laboratory Power Supplies
Laboratory Power Supplies, Linear Controlled
Accessories and Software for Power Supplies
Energy Meters – Standard Models
Training and Seminars with Practical Experience
Space for Personal Notes
Type Index
Article Number Index
Product Spectrum
2
4
5
6
7
8
10
16
18
19
20
21
22
23
24
26
27
28
30
35
36
37
38
39
40
41
42
44
45
48
49
50
51
54
56
57
59
62
67
69
70
71
75
76
79
80
82
83
84
85
86
87
88
89
90
91
92
93
96
98
3
New Products
METRAHIT⏐BASE
METRAHIT⏐PRO
METRAHIT⏐X-TRA
Page
10/11
Page
11
Page
54
Page
77
Page
66
Our new 4½ place, STARLINE generation TRMS multimeters including the METRAHIT⏐BASE with 12, the ⏐PRO with 16
and the ⏐X-TRA with 23 multimeter functions are extremely rugged, reliable digital multimeters with housings made of
impact-resistant plastic. The devices feature a new design and are equipped with state-of-the-art technology.
METRA⏐VIEW
METRA⏐VIEW PC software is a multilingual, measurement data logging program for recording, visualizing, evaluating and
documenting measured values from METRAHIT⏐X-TRA multimeters with reference to time. Communications between
the PC and the measuring instrument(s) is established via the bidirectional USB⏐X-TRA interface adapter.
MINITEST⏐BASE
MINITEST⏐PRO
MINITEST Software
These test instruments are intended for testing and measuring repaired or modified devices.
Testing electrical safety of electrical equipment per DIN VDE 0701-1: 2000 and 0702: 2004.
Indication of limit value violations by means of color LEDs.
With the MINITEST⏐PRO, all measured values are also clearly read out at a large, digital display, and a USB port allows
for convenient, cost-effective measured value reports. Measured data are transmitted to the PC via a USB cable which is
connected to the USB port. MINITEST software, supplied with the instrument on CD ROM, is used for remote control of
the MINITEST⏐PRO, as well as for exporting measurement results to as word processing program.
PS⏐3 Software
Modular, universal software for test instrument, installation, equipment and service management, as well as hazard
analysis and report generation. Automatic read-in and analysis of measured values from tests conducted on systems and
equipment. Systems and equipment management with respective test results stored to a database. Automatic generation
of test reports in accordance with recommendations issued by the trade associations.
METRISO 5024
Analog insulation measuring instrument / low-resistance measuring instrument / voltmeter with buzzer − the analog
insulation measuring instrument for fast two-hand operation per VDE 0413, part 1/2/4.
4
Made in Germany
Recommended Workshop Equipment
Recommended Workshop Equipment According to Guidelines Issued by ZVEH and VDEW
Required Measuring and Test Devices Per Standard
For First-Time Users
Standard
For Most Efficient Work
Test bay
with permanently integrated
measuring instruments
METRATESTER 5-3P
SECUTEST 21F
METRATESTER 5-3P + VL2
METRAVOLT 7A
METRAVOLT 12D
METRA HIT ONE with WZ12A
clip-on current transformer
METRA HIT 25S with WZ12C clip-on
current transformer
METRA HIT 26S with Z3512 clip-on
current transformer
METRACLIP 60
METRACLIP 70
METRACLIP 81
METRISO C
METRISO C
PROFiTEST 0100S-II
(also PGS ... test instrument set)
PROFiTEST 0100S-II
(also PGS ... test instrument set)
DIN VDE 0104
Single-pole voltage tester
DIN VDE 0680, part 6 ProfiSafe 1
2-pole voltage tester
DIN VDE 0680, part 5
Voltmeter
to at least 600 V
DIN VDE 0410
Ammeter
to at least 15 A
DIN VDE 0410
Continuity tester
DIN VDE 0403
Clip-on ammeter
to at least 300 A
Insulation measuring instrument
DIN VDE 0413, part 1
Resistance measuring instrument DIN VDE 0413, part 4 PROFiTEST ONE
Earth tester
DIN VDE 0413,
part 6 or 7
Loop resistance meas. instrument DIN VDE 0413, part 3
Test instrument for RCCBs
DIN VDE 0413, part 6
Phase sequence indicator
DIN VDE 0413, part 9
Measuring instruments for
electrical devices
DIN VDE 0701/0702,
part 1
METRATESTER 5
SECUTEST Sll with PSI Module
Earth tester
DIN VDE 0413, part 5
GEOHM C
GEOHM C
Continuity tester
DIN VDE 0403
ProfiSafe 1
ProfiSafe 1
Illuminance meter
DIN VDE 5032
MAVOLUX 5032C ➀
MAVOLUX 5032B ➀
CableCop 300
CableCop 300
Cable detectors
➀ Sales outlet:
GOSSEN Foto- und Lichtmesstechnik GmbH • Thomas-Mann-Str. 16-20 • 90471 Nürnberg, Germany • Phone: +49 (911) 8602 181 • Fax: +49 (911) 8602 142
Made in Germany
5
Facility Management Solution
Modular Test System
SECUSTAR FM
iF product design award 2005
Modular Test System for User-Controlled Execution of Legally Required
or Company Specified Work Procedures and Directives.
The SECUSTAR FM has been developed for user-controlled execution of approvals, routine
tests and periodic testing in accordance with legally specified directives (e.g. BGV A3, GUV2,
MPG, BetrSichV, fire safety etc.).
Individual work steps can be combined by the user into complete work sequences to this end.
Test sequences generated in this way can then be executed in a user-controlled fashion.
Test sequences, including all required measurements in accordance with the following
standards, have been predefined:
DIN VDE 0701-1, DIN VDE 0702 in preparation, DIN VDE 0751,
NEN 3140, ÖVE 8701-1, ÖVE 8751-1, IEC E 62353
In addition to this, the modular test system allows for the integration of testing tasks through
the connection of sensors, e.g. for the measurement of ambient temperature, relative
humidity and light. In addition to test data archiving and management within the instrument,
data exchange with visual FM or PS3 is also possible.
All of the values required for approval reports or device logbooks for electrical equipment (e.g.
per ZVEH) can be measured with this test instrument.
Test data can be printed in standard or user created report forms by means of an
interconnected printer.
• Testing for (electrical) safety of operating equipment executed by trained persons
• Predefined, standardized test steps and test sequences
• Can be easily supplemented with individual test steps and test sequences
• Operation via color touch-screen
• Sensors for temperature, atmospheric humidity, luminous intensity etc. can be connected via
USB interface
• Mains-independent operation with rechargeable batteries
• Country-specific mains cable and test socket for electrical testing
• Internal data memory for more than 1000 objects, data exchange via compact flash, USB, LAN
• Data entry with soft-keys or USB input media (keyboard, barcode, transponder etc.)
• List generator for the evaluation of stored object data
• Data interfaces:
– USB for connecting PC, printer or sensor
– Ethernet, CF
• Dimensions (W x D x H): 325 x 250 x 90 mm, approximate weight: 2.4 kg with batteries
• Manufacturer’s guarantee: 3 years material and workmanship, 1 year for calibration
● Included with M7020-V001: Basic instrument with automated test sequence for DUTs
with line frequencies of 50/60 Hz, USB and RS 232 interface,
online instructions in German, English in preparation,
earthing contact plug and outlet,
special cable with test probe, plug-on alligator clip,
3 plug-on quick clips, test report,
operating instructions in all available languages
as PDF file on CD ROM
● For optional accessories refer to the table on page 7.
● See visual FM analysis software on page 7,
see PS3 AM analysis software and PS3 update on page 77.
➲ See page 91 for training seminar: GTT3010
6
Type
Data Sheet No.
Article Number
SECUSTAR FM
3-349-310-03
M7020-V001
DKD calibration certificate
−
Z752A
Maintenance contract
−
Z752B
−
Made in Germany
Facility Management Solution
Accessories for Modular Test System
Accessories for SECUSTAR FM
Sensors, Plug Inserts and Adapters, Software, Carrying Cases, Hard Cases
and Other Accessories
Z751B: temperature / humidity sensor for USB connection
For measuring temperature and relative humidity
Z745G
Z751A
Z751B
Z751C
Z751C: light sensor for USB connection, MAVOLUX 5032B USB
Digital luxmeter with large range of applications, classified per DIN 5032-7 and CIE no. 69 – for
inspecting light sources, for example street lights.
For monitoring illumination at workstations, in buildings, and in sports and parking facilities.
For quality inspection of light sources during lamp and light bulb manufacturing.
For illumination designers and architects, as well as for agriculture and forestry applications.
Z750A: 3-phase 16 A differential current adapter, AT16-DI
Z750B: 3-phase 32 A differential current adapter, AT32-DI
For testing in accordance with DIN VDE 0701, 0702 and 0751 at 3-phase devices with 5-pole CEE
connection, in particular for the measurement of loop current using the differential current method
Z721D
Z715A: SECU-cal 10 calibration adapter for tests per DIN VDE 0701/0702 with test report
Z745G: brush probe
For measuring protective conductor resistance, e.g. at rotating devices under test
Z750A/B
Z751A: barcode scanner for USB connection
For identifying devices and system components. Devices and system components can be logged by
the test instrument, and acquired measured values can be allocated to them with the scanner.
Z715A
Z721D: barcode and label printer including software for USB connection
Barcode and label printer for connection to a PC, for self-adhesive, smudge-proof barcode labels. For
identifying devices and system components. Devices and system components can be logged by our
test instruments, and acquired measured values can be allocated to them with the scanner.
F2010: SECUSTAR carrying pouch
Carrying pouch for mobile use, with retaining clips for sensors
K2010: carrying case for SECUSTAR FM and accessories
Aluminum case, approximate dimensions: 645 x 535 x 160 mm
vFM Software
F2000: universal carrying pouch
The universal carrying pouch is suitable for many different measuring and test instruments, as well as
accessories. Dimension: 380 x 310 x 200 mm.
Z753A: package of 3 touch-screen wands (no photo)
For data entry via LCD touch-screen
F2000
Z753B: package of 2 retaining clips (no photo)
Sensor retaining clips (included with SECUSTAR carrying pouch)
K2010
visual FM
Facility management software for commercial, infrastructural and technical administration of all types
of properties and objects, from property management right on up to administration of buildings, floor
space, rooms, systems, medical technology, building services, vehicle pools, furnishings, cable
networks, electrical circuits etc. Building structures, machines, equipment etc. can be precisely
implemented and represented in the form of any desired objects in accordance with your special
requirements.
Z722D: label set for Z721D barcode and label printer (no photo), self-adhesive, smudge-proof
Z722D: 3 x 24 mm, 1 x 18 mm, 1 x 9 mm wide, Z722E: 5 x 18 mm, 8 meters long.
F2010
Type
Sensors,
plug inserts
and adapters
Accessories
Z751B
Designation
Article Number
Temperature / humidity sensor for USB connection
Z751B
Light sensor for USB connection
Z751C
AT16-DI
3-phase 16 A differential current adapter
Z750A
AT32-DI
3-phase 32 A differential current adapter
Z750B
MAVOLUX 5032B USB
SECU-cal 10
Calibration adapter for testing per DIN VDE 0701/0702 with test report
Z715A
Brush Probe
For measuring protective conductor resistance, e.g. at rotating devices under test
Z745G
Z751A
Barcode scanner for USB connection
Z751A
Z721D
Barcode and label printer including software for USB connection
Z721D
Z700E
F2010
SECUSTAR carrying pouch
K2010
Carrying case for SECUSTAR FM and accessories
Z504L
F2000
Universal carrying pouch
Z700D
Z753A
Package of 3 touch-screen wands
Z753A
Z753B
Package of 2 retaining clips
Z753B
PC analysis software
visual FM
Facility management software for technical building management
Consumable materials
Z7160
Z722D
Label set for Z721D barcode and label printer
Z722D
Z722E
Label set for Z721D barcode and label printer
Z722E
Made in Germany
−
7
METRA Hit Series Multimeter Overview
METRA HIT
Catalog page
DC voltage measurement
Intrinsic error with V DC
BASE
Intrinsic error, AC
23S
24S
10
11
12
12
13
13
10 μV...1000 V
10 mV...600 V
10 μV...1000 V
10 μV...600 V
10 μV...1000 V
±0.05% rdg.+3 d ±0.05% rdg.+3 d ±0.05% rdg.+3 d ±0.5% rdg.+3 d ±0.05% rdg.+3 d ±0.05% rdg.+3 d ±0.05% rdg.+3 d
± 1% rdg.+3 d
Intrinsic error, DC
22S/M
10 μV...1000 V
10 μV...1000 V
AC current measurement
ONE
10
Intrinsic error with V AC
DC current measurement
X-TRA
10 μV...1000 V
AC voltage measurement
TRMS
PRO
10 μV...1000 V
10 μV...1000 V
±0.2% rdg.+30 d ±0.2% rdg.+30 d
1 mV...600 V
± 1% rdg.+3 d
10 μV...1000 V
10 mV...600 V
10 μV...1000 V
±0.2% rdg.+30 d ±0.2% rdg.+30 d ±0.2% rdg.+30 d
AC, AC+DC
AC, AC+DC
AC, AC+DC
−
−
−
−
With clip
100 μA...10 A
10 nA...10 A
0.1 A...10 A (16 A)
(with clip)
10 nA...10 A
10 nA...10 A
−
With clip
−
±0.1% rdg.+5 d ± 0.05% rdg.+5 d ±1.0% rdg.+5 d
10 nA ... 10 A
10 nA ... 10 A
±0.5% rdg.+30 d ±0.5% rdg.+30 d
-
±0.1% rdg.+5 d
±0.1% rdg.+5 d
1.0 A...10 A (16 A)
(with clip)
10 nA ... 10 A
10 nA ... 10 A
±1,.% rdg.+2 d
−
±0.5% rdg.+30 d ±0.5% rdg.+30 d
AC, AC+DC
AC, AC+DC
AC, AC+DC
−
−
−
−
Resistance measurement
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
Intrinsic error, resistance
±0.1% rdg.+5 d
TRMS
±0.2% rdg.+3 d
±0.2% rdg.+3 d
±0.2% rdg.+3 d
±0.7% rdg.+3 d
±0.1% rdg.+5 d
±0.1% rdg.+5 d
4-wire
−
−
−
−
−
−
−
Insulation resistance measurement
−
−
−
−
−
−
−
Capacitance Measurement
−
−
−
0.001 nF...30 mF 0.001 nF...30 mF 0.001 nF...30 mF
Intrinsic error, capacitance
−
−
−
±1.0% rdg.+6 d
±1.0% rdg.+6 d
±1.0% rdg.+6d
Temp. measurement, Pt100/1000
−
−
-200°...+850°
-200°...+850°
-200°...+850°
-200°...+850°
-200°...+850°
-270°...+1372°
-270°...+1372°
-270°...+1372°
−
−
−
−
✔
✔
✔
✔
✔
✔
✔
5.1 V
5.1 V
5.1 V
2V
3V
3V
3V
Type J and K thermocouples
Continuity testing
Diode test
Frequency measurement
0.01 Hz...100 kHz 0.01 Hz...100 kHz 0.001 Hz ...1 MHz
−
0.01 Hz...100 kHz 0.01 Hz...100 kHz 0.01 Hz...100 kHz
Level measurement
−
−
−
−
-48 dB...+63 dB
-48 dB...+63 dB
Power measurement
−
−
−
−
−
−
−
Events counter, event duration
−
−
−
−
✔
✔
✔
Frequency and pulse generator
−
−
−
−
✔
✔
✔
Stopwatch
−
−
−
−
✔
✔
✔
DATA / Min-Max storage
✔
✔
✔
✔
✔
✔
✔
Data storage (measured values)
−
−
500 kB (15400)
−
22 M:
128 kB (60000)
−
−
Analog display, 35/36 scale graduations
Digital display (places/digits)
-48 dB...+63 dB
✔
✔
✔
✔
✔
✔
✔
4½ = 12000 d
4½ = 12000 d
4½ = 12000 d
3¾ =3100 d
4¾ = 31000 d
4¾ = 31000 d
4¾ = 31000 d
Dual display / multiple display
−
−
−
−
−
−
−
Display illumination
✔
✔
✔
−
−
−
−
Measurements per second
40 analog / 10 digital 40 analog / 10 digital 40 analog / 10 digital 20 analog / 2 digital 20 analog / 2 digital 20 analog / 2 digital 20 analog / 2 digital
Bandwidth
1 kHz
10 kHz
20 kHz
1 kHz
1 kHz
1 kHz
1 kHz
IR Interface
−
−
✔
✔ (ONE plus)
✔
✔
✔
Automatic blocking sockets
✔
✔
✔
✔
✔
✔
✔
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 600 V
CAT IV / 600 V
CAT II / 600 V
CAT III / 1000 V
CAT IV / 600 V
Measuring category
Calibration certificate
DKD
DKD
DKD
−
DKD
DKD
DKD
Weight with batteries
395 gr.
395 gr.
395 gr.
350 gr.
350 gr.
350 gr.
350 gr.
Battery / service life
Dimensions in mm (W x H x D)
2 ea. 1.5 V / 200 hr. 2 ea. 1.5 V / 200 hr. 2 ea. 1.5 V / 200 hr.
9 V / to 750 hr.
2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr.
89 x 199 x 43
89 x 199 x 43
89 x 199 x 43
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
Manufacturer’s Guarantee
3 years
3 years
3 years
3 years
3 years
3 years
3 years
Approvals and certificates
CE
CE
CE
CE, CSA
CE, CSA
CE, CSA
CE, CSA
Cable sets,
demo software
Cable sets,
demo software
Cable sets,
demo software
Cable sets
Cable sets
Cable sets
Cable sets
METRA VIEW
METRAwin 10
METRAwin 10
METRAwin 10
METRAwin 10
Accessories / included
Software option
8
84 x 195 x 35
Made in Germany
METRA Hit Series Multimeter Overview
25S
26S/M
28S
29S
30M
16I; 16T; 16U
27M; 27I/AS
28C
14
14
15
15
16
16/ 17
21
25
10 μV...1000 V
10 μV...1000 V
1 μV...600 V
1 μV...600 V
0.1 μV...600 V
30 mV...600 V
3 V...600 V
300 mV...600 V
±0.25% rdg.+1d
±0.1% rdg.+5d
±0.05% rdg.+15d
3 V...600 V
3 V...600 V
300 mV...600 V
±0.05% rdg.+3d ±0.05% rdg.+3d ±0.02% rdg.+5d ±0.02% rdg.+5d ±0.003% rdg.+3d
10 μV...1000 V
10 μV...1000 V
10 mV...600 V
10 mV...600 V
1 μV...600 V
±0.2% rdg.+30d ±0.2% rdg.+30d ±0.2% rdg.+30d ±0.2% rdg.+30d ±0.08% rdg.+5d
AC
AC, AC+DC
AC, AC+DC
AC, AC+DC
AC+DC
AC, AC+DC
−
AC
10 nA...10 A
10 nA...10 A
1 nA...10 A
1 nA...10 A
100 pA ... 120 mA
With clip
With clip
3 mA...300 mA
±0.1% rdg.+5 d
10 nA...10 A
±0.1% rdg.+5 d ± 0.05% rdg.+5 d ±0.05% rdg.+5 d ±0.02% rdg.+5 d
10 nA...10 A
10 nA...10 A
10 nA...10 A
1 nA ... 120 mA
±0.5% rdg.+30 d ±0.5% rdg.+30 d ±0.5% rdg.+30 d ±0.5% rdg.+30 d ±0.1% rdg.+5 d
AC+DC
−
−
−
30Ω ...30 MΩ
300Ω ...30 MΩ
300 Ω...30 MΩ
0.001 mΩ...30 Ω
3 mΩ...30 Ω
27I / AS:
10 kΩ ... 3 GΩ at
50/100/250/500 V
−
−
3 nF...30 F
AC
AC+DC
AC+DC
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
0.01 Ω...30 MΩ
±0.1% rdg.+5d
±0.1% rdg.+5d
±0.05% rdg.+5d ±0.05% rdg.+5d ±0.005% rdg.+5d
−
−
−
−
0.1 mΩ...30Ω
−
−
−
−
−
16I:
1 kΩ ... 3.1 GΩ at 500/1000 V
16T/16U:
1 kΩ ... 0.31 GΩ at 100 V
−
30 nF ... 3 μF / 16I/T: 30 μF
0.001 nF...30 mF 0.001 nF...30 mF 0.001 nF...30 mF 0.001 nF...30 mF
±1.0% rdg.
AC+DC
0.01 Ω...30 MΩ 0.1 mΩ...12 MΩ
±1.0% rdg.+6d
±1.0% rdg.+6d
±1.0% rdg.
−
-200°...+850°
-200°...+850°
-200°...+850°
-200°...+850°
-200°...+850°
-200°...+800°
-200°...+600°
-200°...+850°
−
−
-270°...+1372°
-270°...+1372°
-270°...+1372°
−
−
-270°...+1820°
✔
✔
✔
✔
✔
✔
✔
✔
3V
3V
3V
3V
−
2V
3V
3V
0.01 Hz...100 kHz 0.01 Hz...100 kHz 0.001 Hz...100 kHz 0.001 Hz...100 kHz 0.001mHz...100kHz
300 Hz...100 kHz
300 Hz...3 kHz
300 Hz...3 kHz
-48 dB...+63 dB
-48 dB...+63 dB
-48 dB...+63 dB
-48 dB...+63 dB
−
−
−
−
−
−
−
1 mW...10 kW
−
−
−
−
✔
✔
✔
✔
−
−
−
−
✔
✔
-
−
−
−
−
−
✔
✔
✔
✔
−
−
−
✔
✔
✔
✔
✔
✔ (MIN-MAX only)
✔
−
26M:
128 kB (60000)
−
✔
128 kB (30000)
✔
✔
32 kB (1000)
128 kB (3000)
✔
✔
−
−
−
✔
−
−
4¾ = 31000 d
4¾ = 31000 d
5¾ = 310000 d
5¾ = 310000 d
6½ = 1200000 d
3¾ =3100 d
4¾ = 31000 d
5¾ = 310000 d
−
−
✔
✔
−
−
−
−
−
−
−
−
−
− / 16U: ✔
✔
−
1digital
−
−
−
1 kHz
1 kHz
1 kHz
✔
✔
CAT II / 600 V
CAT II / 250 V
20 analog / 2 digital 20 analog / 2 digital 20 analog / 2 digital 20 analog / 2 digital
1 kHz
20 kHz
100 kHz
100 kHz
100 kHz
✔
✔
✔
✔
✔
✔
✔
✔
✔
−
−
✔ / 16U: −
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT II / 600 V
CAT II / 600 V
CAT III / 300 V
DKD
DKD
DKD
DKD
DKD
DKD
DKD
DKD
350 gr.
350 gr.
350 gr.
405 gr.
350 gr.
350 gr.
350 gr.
420 gr.
2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr. 2 ea. 1.5 V / 100 hr.
9 V / to 750 / 16U: 500 hr.
3 ea. 1.5 V / to 20 hr.
3 ea. 1.5 V / to 70 hr.
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
84 x 195 x 35
3 years
3 years
3 years
3 years
3 years
3 years
3 years
3 years
CE, CSA
CE, CSA
CE, VDE-GS, CSA
CE
CE, CSA
CE, VDE-GS, CSA / 16U: CE
CE, CSA
Cable sets
Cable sets
Cable sets
Cable sets
Cable sets
Cable sets,
16U: carrying pouch
METRAwin 10
METRAwin 10
Made in Germany
METRAwin 10
METRAwin 10
METRAwin 10
16I / 16U: METRAwin 10
Cable sets, pouch
27 AS : carrying case,
METRAwin 10,
Kelvin clip+probe set
METRAwin 10, 90-2
CE
Cable sets
METRAwin 10, 90-2
9
Handheld Digital Multimeters
Our new STARLINE generation instruments, including METRAHIT⏐BASE, PRO and X-TRA, are highly rugged,
reliable digital multimeters with housings made of impact-resistant plastic. The devices feature a new design
and are equipped with state-of-the-art technology, for example:
• Resolution: ± 12,000 digits, 4½ places
• 3 connector jacks with patented automatic blocking sockets (ABS)
• Voltage measurement with a basic accuracy of ± 0.05% (V DC)
• Auto-ranging current measurement from 100 μA (resolution: 10 nA) to 10 A (16A) via a single connector jack and a
single fuse
• Large, light-blue illuminated display with extra large characters (15 mm) and an analog bar graph for dynamic
processes
• Separate battery and fuse compartments
• IP 52 protection against dust and water
• Measuring categories: 1000V CAT III and 600V CAT IV
• Made in Germany
• Furnished with DKD calibration certificate
• Min-Max measuring rate: 40 measurements per second
METRAHIT⏐BASE
TRMS Voltage Multimeter
4½ place TRMS digital multimeter −
resolution: 12,000 digits − 12 multimeter functions
• VoltageAC TRMS − voltageAC+DC TRMS − voltageDC
• Frequency (Hz) − resistance − continuity test − diode test
• CurrentTRMS via additional current sensors with voltage output
• Adjustable clip parameters
• Temperature with type K thermocouples
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration
(depending upon application)
● Included:
Multimeter with KS17-2 measurement cable set, two 1.5 V mignon batteries (AA),
condensed operating instructions, CD ROM with operating instructions (English/German),
data sheet and METRA⏐View demo software, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRAHIT⏐PRO
Type
Data Sheet No.
Article Number
METRAHIT l BASE
3-349-350-03
M241A
TRMS Professional Multimeter
4½ place TRMS digital multimeter for professional use −
resolution: 12,000 digits − 16 multimeter functions
• VoltageAC TRMS − voltageAC+DC TRMS − voltageDC
• Frequency (Hz) − resistance − continuity test − diode test
• CurrentAC TRMS − current AC+DC TRMS
• Temperature with type K thermocouples
• Additional filter function and voltage measurement with reduced input impedance for limiting interference, for
example when performing measurements at frequency converters
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration
(depending upon application)
● Included:
Multimeter with KS17-2 measurement cable set, two 1.5 V mignon batteries (AA),
condensed operating instructions, CD ROM with operating instructions (English/German),
data sheet and METRA⏐View demo software, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
10
Type
Data Sheet No.
Article Number
METRAHIT l PRO
3-349-350-03
M242A
Made in Germany
Handheld Digital Multimeters
METRAHIT⏐X-TRA
TRMS System Multimeter
4½ place high-end TRMS digital multimeter, system compatible with data memory and
IR interface − resolution: 12,000 digits − 23 multimeter functions
• VoltageAC TRMS − voltage AC+DC TRMS − voltageDC
• Frequency (Hz, MHz) − keying ratio − resistance − continuity test − diode test − capacitance
• CurrentAC TRMS − current AC+DC TRMS
• Temperature with Pt 100/1000 sensors and type K thermocouples
• Additional filter function and voltage measurement with reduced input impedance for limiting interference, e.g.
when performing measurements at frequency converters
• 500 KB data memory as data logger for long-term measurements
• Power pack connector socket for operation without batteries
• Infrared interface for communication with the PC
• Protective rubber cover safeguards against shocks and impacts
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
Multimeter with KS17-2 measurement cable set, two 1.5 V mignon batteries (AA),
condensed operating instructions, CD ROM with operating instructions (English/German),
data sheet and METRA⏐View demo software, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA⏐VIEW
Type
Data Sheet No.
Article Number
METRAHIT l X-TRA
3-349-350-03
M240A
PC Software
METRA l VIEW PC software is a multilingual, measurement data logging program for
recording, visualizing, evaluating and documenting measured values from
METRAHIT ⏐ X-TRA multimeters with reference to time.
Communications between the PC and the measuring instrument(s) is established via the bidirectional IR-USB
interface adapter.
Depending upon device type, one or several of the following operating modes are possible:
• Measuring instrument parameters configuring − online recording of measurement data − read-out stored data
• Measured value display − graphic representation (can be saved as a BMP file or read out to a printer)
Demo software with limited functions is included with the instrument, or can be downloaded via the Internet.
Accessories
Type
Data Sheet No.
Article Number
METRA l VIEW
3-349-350-03
Z211G
89,–
Accessories for METRAHIT l Multimeters
GH X-TRA:
Protective rubber cover and carrying strap for METRAHIT BASE/PRO/X-TRA
NA X-TRA (no photo):
Power pack: AC 90 ... 250 V / DC 5 V / CAT IV 600 V
USB X-TRA:
Bidirectional IR-USB interface adapter for METRAHIT X-TRA
FF (UR)10A/1kV AC-DC (no photo):
Fuses (pack of 10) for METRAHIT X-TRA, PRO, 28S, 29S
Made in Germany
Type
Data Sheet No.
GH X-TRA
−
Article Number
Z104C
NA X-TRA
−
Z218G
USB X-TRA
−
Z216C
FF (UR)10A/1kV AC-DC
−
Z109L
11
Handheld Digital Multimeters
METRA HIT ONE
3¾ Place Digital Multimeter with Analog Bar Graph and Temperature Measuring Instrument
Universal auto-ranging multimeter for use in all areas of electrical engineering. The MetraHit ONE provides users with
all the measuring functions of a highly diverse multimeter: convincing technology with all voltage, resistance, current
and temperature measuring ranges, and additional measuring functions and automatic functions.
•
•
•
•
•
•
•
•
•
•
•
•
Resolution: +/- 3100 digits plus analog bar graph
Patented automatic blocking sockets (ABS)
Voltage: 30 mV to 600 V DC and 3 to 600 V AC
Current: 300 μA to 10 A DC (16 A 30 sec.) and 3 mA to 10 A AC (16 A 30 sec.)
Resistance: 30 Ω to 30 MΩ
Temperature: -200.0° C to +850.0° C, Pt100-Pt1000
Continuity and diode testing
Min-Max measured value storage and DATA hold
IR interface (METRA HIT ONE plus)
600 V CAT lll per IEC 61010-1
CSA certificate
Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M204B: Digital multimeter with battery, measurement cable set and
condensed operating instructions
M204C: Same as M204B plus protective rubber cover
M204D: Same as M204B plus IR interface and protective rubber cover
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 22S 12
Type
Data Sheet No.
METRA HIT ONE
3-349-237-03
Article Number
M204B
METRA HIT ONE with protective rubber cover
3-349-237-03
M204C
METRA HIT ONE plus
3-349-237-03
M204D
4¾ Place Precision Multimeter and Temperature Measuring Instrument,
METRA HIT 22M same as 22S plus Data Logger
Universal, basic multimeter for professional training, as well as electrical and energy applications,
no direct current measurement, no fuses: very cost effective with low maintenance costs
• Display range: +/- 30,000 digits and analog bar graph
• Intrinsic error: 0.05% of the measured value + 3 digits
• Measuring functions: 300 mV to 1000 V, 300 Ω to 30 MΩ, 3 nF to 30 mF, dBV, Hz, °C and °F
• Stopwatch from 10 ms to 100 minutes
• A AC with additional type WZ12C current sensor with mV output
• Min-Max measured value storage, DATA hold
• Continuity and diode testing
• Frequency and pulse generator: 1 Hz to 1 kHz
• Automatic range selection and battery cutoff
• METRA HIT 22M with integrated 128 kB measurement data memory, 1 ms to 10 minute sampling interval,
versatile trigger functions
• Patented automatic blocking sockets (ABS)
• IR data interface
• Integrated quartz movement
• Protective rubber cover
• Optional METRAwin 10 software
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 600 V or CAT III at 1000 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M222A: Digital multimeter with batteries, measurement cable set,
operating instructions, DKD calibration certificate
M222F: Same as M222A plus GH18 protective rubber cover
M222B: Same as M222F plus 128 kB measured value memory
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
12
Type
Data Sheet No.
Article Number
METRA HIT 22S
3-349-026-03
M222A
METRA HIT 22S with protective rubber cover
3-349-026-03
M222F
METRA HIT 22M
3-349-026-03
M222B
Made in Germany
Handheld Digital Multimeters
METRA HIT 23S
4¾ Place Special Multimeter and Temperature Measuring Instrument for Energy Technology
Special multimeter for energy technology (power plants, utility companies):
no fuse in 16 A measuring circuit and thus suitable for 0 to 5 A current transformer circuits
• Display range: +/- 30,000 digits
• Intrinsic error: 0.05% of the measured value + 3 digits
• Measuring functions: 300 mV to 1000 V, 300 μA to 16 A, 300 Ω to 30 MΩ, 3 nF to 30 mF, dBV, Hz, °C and °F
• Stopwatch from 10 ms to 100 minutes
• Min-Max measured value storage, DATA hold
• Continuity and diode testing
• Frequency and pulse generator, 1 Hz to 1 kHz
• Automatic range selection and battery cutoff
• Heavy-duty mA fuse with 1000 V nominal voltage
• Patented automatic blocking sockets (ABS)
• IR data interface
• Integrated quartz movement
• Protective rubber cover
• Optional METRAwin 10 software
• Extended AAC by means of additional current transformer with mA output
• CSA certificate
• DKD calibration certificate as standard feature
• CAT II at 600 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M223A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 24S
Type
Data Sheet No.
Article Number
METRA HIT 23S
3-349-026-03
M223A
4¾ Place Precision Multimeter and Temperature Measuring Instrument for Universal Use
Low-cost universal instrument for electricians, process engineers, schools etc.
• Display range: +/- 30,000 digits
• Intrinsic error: 0.05% of the measured value + 3 digits
• Measuring functions: 300 mV to 1000 V, 300 μA to 10 A, 300 Ω to 30 MΩ, 3 nF to 30 mF, dBV, Hz, °C and °F
• Stopwatch from 10 ms to 100 minutes
• Min-Max measured value storage, DATA hold
• Continuity and diode testing
• Automatic range selection and battery cutoff
• Heavy-duty mA fuse with 1000 V nominal voltage
• Patented automatic blocking sockets (ABS)
• IR data interface
• Integrated quartz movement
• Protective rubber cover
• Optional METRAwin 10 software
• Extended AAC by means of additional current transformer with mA output
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 600 V or CAT III at 1000 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M224A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
Made in Germany
Type
Data Sheet No.
Article Number
METRA HIT 24S
3-349-026-03
M224A
13
Handheld Digital Multimeters
METRA HIT 25S
4¾ Place TRMS Multimeter and Temperature Measuring Instrument for Universal Use
Cost-effective TRMSAC digital multimeter for universal use in electrical and electronics applications
with distorted AC signals
• Display range: +/- 30,000 digits
• Intrinsic error: 0.05% of the measured value + 3 digits
• Measuring functions: 300 mV to 1000 V AC (TRMS), bandwidth from 20 Hz to 1k Hz, 300 μA to 10 A, 300 Ω to 30 MΩ,
3 nF to 30 mF, dBV, Hz, °C and °F
• Stopwatch from 10 ms to 100 minutes
• Min-Max measured value storage, DATA hold
• Continuity and diode testing
• Automatic range selection and battery cutoff
• Heavy current fuses with 1000 V nominal voltage
• Patented automatic blocking sockets (ABS)
• IR data interface
• Integrated quartz movement
• Protective rubber cover
• Optional METRAwin 10 software
• Extended AAC by means of additional current transformer
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 600 V or CAT III at 1000 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M225A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 26S/26M
Type
Data Sheet No.
Article Number
METRA HIT 25S
3-349-026-03
M225A
4¾ Place Precision TRMS Multimeter and Temperature Measuring Instrument for Demanding
Universal Use, 26M with Data Logger
Digital multimeter for demanding universal applications, TRMS measurement for AC and AC+DC, with broad-band (20 kHz),
high-speed TRMS value converter
• Display range: +/- 30,000 digits
• Intrinsic error: 0.05% of the measured value + 3 digits
• Measuring functions: 300 mV to 1000 V, TRMSAC+DC and TRMSAC, bandwidth from 16 Hz to 20 kHz, 300 μA to 10 A, 300
Ω to 30 MΩ, 3 nF to 30 mF, dBV, Hz, °C and °F
• Stopwatch from 10 ms to 100 minutes
• Min-Max measured value storage, DATA hold
• Continuity and diode testing
• Frequency and pulse generator, 1 Hz to 1 kHz
• Automatic range selection and battery cutoff
• Heavy current fuses with 1000 V nominal voltage
• METRA HIT 26M with integrated 128 kB measurement data memory, 1 ms to 10 minute sampling interval,
versatile trigger functions
• Patented automatic blocking sockets (ABS)
• IR data interface
• Integrated quartz movement
• Protective rubber cover
• Optional METRAwin 10 software
• Extended AAC by means of additional current transformer with mA output
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 600 V or CAT III at 1000 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M226A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
M226B: Same as M226A plus 128 kB measured value memory
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
14
Type
Data Sheet No.
METRA HIT 26S
3-349-026-03
Article Number
M226A
METRA HIT 26M
3-349-026-03
M226B
Made in Germany
Handheld Digital Multimeters
METRA HIT 28S
5¾ Place, Multifunctional, Precision TRMS Multimeter, System Compatible
Precision multimeter for universal use in the field of energy electronics, and for high bandwidth electronics from
16 Hz to 100 kHz and TRMSAC / TRMSAC+DC
• Triple display: ± 310,000 digits
• Minimal intrinsic error: ± (0.02% + 10 digits for V DC)
• Measuring functions: 300 mV to 1000 V, 300 μA to 100 A, 300 Ω to 30 MΩ, 3 nF to 30 mF, dBV, Hz,
°C and °F (Pt100/Pt1000, type K and J thermocouples with reference junction)
• Patented automatic blocking sockets (ABS)
• IR Interface
• Continuity and diode testing
• Min-Max measured value storage, DATA hold
• With cable set, protective rubber cover and DKD calibration certificate
• Optional METRAwin 10 software
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 300 V or CAT III at 600 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M228A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 29S
Type
Data Sheet No.
Article Number
METRA HIT 28S
3-348-866-03
M228A
5¾ Place Precision TRMS Multimeter, Power Meter and Power Disturbance Measuring
Instrument with Data Logger
Precision multimeter, power multimeter and power disturbance measuring instrument with integrated memory for
universal use in the field of energy electronics, and for high bandwidth electronics from 16 Hz to 100 kHz and
TRMS AC /TRMS AC+DC
• Triple display: ± 310,000 digits
• Minimal intrinsic error: ± (0.02% + 10 digits for V DC)
• Measuring functions: 300 mV to 1000 V, 300 uA to 100 A, 300 Ohm to 30 MOhm, 3 nF to 30 mF, dBV, Hz, °C and °F
(Pt100/Pt1000, type K and J thermocouples with reference junction)
• W, VA, VAr, Wh, VAh, peak load profile, power disturbance measurement, power disturbance recording
• Patented automatic blocking sockets (ABS)
• IR Interface
• Continuity and diode testing
• Integrated 128 kB measured value memory, 0.5 s to 10 minute sampling interval
• Versatile trigger functions
• Min-Max measured value storage, DATA hold
• With cable set, protective rubber cover and DKD calibration certificate
• Optional METRAwin 10 software
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 300 V or CAT III at 600 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M229A: Digital multimeter with batteries, measurement cable set, operating instructions,
DKD calibration certificate
M229E: Same as M229A in HC30 carrying case with WZ12D current sensor, TF220 temperature
sensor and BD-Pack1 (BD232 interface adapter, cable, METRAwin 10 software)
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
Made in Germany
Type
Data Sheet No.
Article Number
METRA HIT 29S
3-348-866-03
M229A
METRA HIT 29S Set 1
–
M229E
KS29 safety cable set
–
Z229A
15
Handheld Digital Multimeters
Hand-Held Digital Multimeters with Insulation Tester
METRA HIT 30M
6½ Place, Precision TRMS Multimeter, Temperature Measuring Instrument and Data Logger
Precision multimeter, temperature measuring instrument and data logger for demanding universal use in the laboratory
and for service applications
• Display range:+/- 1,200,000 digits
• Intrinsic error: +/- (35 ppm of the measured value + 70 ppm)
• Measuring functions: 120 mV to 600 VDC and TRMSAC+DC (bandwidth from 16 Hz to 100 kHz), 120 μA to 120 mA,
120 Ω to 12 MΩ, 1 Hz to 100 kHz, °C and °F (Pt100, Pt1000, J, K)
• Resistance and temperature measurement with Kelvin terminal
• Min-Max measured value storage
• Automatic range selection and battery cutoff
• PTC fuse, max. 250 V
• Integrated 128 kB measurement data memory, 0.1 s - 10 min. sampling interval
• IR data interface
• Protective rubber cover
• DKD calibration certificate as standard feature
• Power pack (optional)
• CAT III at 300 V or CAT II at 600 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M230B: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 16I
Type
Data Sheet No.
Article Number
METRA HIT 30M
3-348-979-03
M230B
Digital-Analog TRMS Multimeter with Insulation Measurement for Service Technicians
This inexpensive universal multimeter is designed for use by electrical service technicians. In addition to a multimeter,
it includes a 500 V / 1000 V insulation tester in accordance with VDE 0413, and a precision temperature indicator. The
optional WZ12B clip-on meter allows for easy, safe measurements of up to 30 A / 100 A.
• Rugged digital multimeter, ±3100 digits,
• With analog display
• Patented automatic blocking sockets (ABS)
• IR Interface
• V DC, V AC-DC, V AC, Ω, °C (Pt100/Pt1000)
• Continuity and diode testing
• Min-Max measured value storage, DATA hold
• Minimal intrinsic error: ± (0.25% + 1 digit for V DC)
• With cable set and protective rubber cover
• CSA certificate
• DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M216B: Digital multimeter with GH18 protective rubber cover, battery, KS17 cable set,
operating instructions, DKD calibration certificate
M216E: Same as M216B in HC20 measuring case with GH18 protective rubber cover and
TF220 temperature sensor
M216F: Same as M216B in HC20 measuring case with GH18 protective rubber cover,
WZ12B clip-on current sensor and TF220 temperature sensor
● For optional accessories refer to the table on page 28:
➲ See page 91 for training seminar: GTT1219B
16
Type
Data Sheet No.
Article Number
METRA HIT 16I
3-348-972-03
M216B
METRA HIT 16I Set 1
3-348-972-03
M216E
METRA HIT 16I Set 2
3-348-972-03
M216F
Made in Germany
Hand-Held Digital Multimeters with Insulation Tester
METRA HIT 16T
Digital-Analog TRMS Multimeter with Insulation Measurement for Telecommunications Service
METRA HIT 16T, same as 16I but optimized with 100 V insulation measurement for telecommunications service
• Rugged digital multimeter, ±3100 digits, with analog display
• Patented automatic blocking sockets (ABS)
• IR Interface
• V DC, V AC-DC, V AC, Ω, °C (Pt100/Pt1000)
• Continuity and diode testing
• Min-Max measured value storage, DATA hold
• Minimal intrinsic error: ± (0.25% + 1 digit for V DC)
• With cable set and protective rubber cover
• CSA certificate
• DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M216A: Digital multimeter with GH18 protective rubber cover, battery, KS17 cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
METRA HIT 16U
Type
Data Sheet No.
Article Number
METRA HIT 16T
3-348-972-03
M216A
Cable Multimeters for Measurements in Symmetrical Copper Cable Networks
The METRA HIT 16U cable multimeter is a rugged portable measuring instrument for use in the field. It is used to perform
measurements for pinpointing errors in copper cable networks. Interruption of a single core or contact with an
open-circuit core (capacitive asymmetry) can be recognized at the high speed logarithmic bar graph display by
switching polarity.
• Insulation resistance measurement (100 V test voltage) with simultaneous recognition of interference voltage and polarity
reversal for diode testing
• Cable symmetry testing by means of rapid changeover switching
• Multifunctional multimeter (V, Ω, F, Hz)
• AC and AC+DC TRMS measurement
• Scaled current measurement from 10 mA to 100 A with accessory clip-on current sensor
• Precision temperature indication in °C and °F for Pt100/Pt1000 sensors
• Display illumination can be activated, analog display: linear or logarithmic for insulation measurement
• Acoustic signal for continuity testing, dangerous contact voltages, exceeded overload limits
• Min-Max value storage
• IP 54 housing, protective rubber cover as standard feature
• Windows software available as accessory for processing and graphic display of measured values via RS 232 interface
• DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M216U: Digital multimeter with F836 carrying pouch, GH18 protective rubber cover, battery,
KS21T special cable set, operating instructions and DKD calibration certificate
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
Made in Germany
Type
Data Sheet No.
Article Number
METRA HIT 16U
3-349-227-03
M216U
17
Analog-Digital, Handheld Analog Multimeters
METRAmax ® 12
Digital-Analog Multimeter for Electrical Applications
Favorably priced hand-held multimeters for professional results.
Suitable for use in the fields of general electronics and electrical engineering.
• ± 4000 digits with bar graph
• Voltage measurement from 400 mV to 600 V AC/DC/AC
• Switchable input resistance: 10 MΩ / 400 kΩ
• Intrinsic error, VAC/DC: ± 0.5% of measured value +2 digits,
• VAC: ±1% of measured value +5 digits
• Current measurement: 40, 400 mA AC/DC/DC, 10 A =/~ (12 A max. 5 min.)
• Intrinsic error, AAC/DC: ± 0.8% of measured value +2 digits
• AAC: ± 1% of measured value + 5 digits
• Resistance measurement: 400 Ω to 40 MΩ
• Frequency measurement: 10 Hz to 400 kHz
• Capacitance measurement: 4 nF to 40 uF
• Continuity and diode testing, Min, Max and HOLD memory
• Case with tilt stand and take-up reel
• Dimensions (W x H x D): 92 x 154 x 25 mm
• Weight: approx. 0.2 kg with batteries
• Batteries: 2 ea. 1.5 V IEC LR 6 (AA mignon)
• CSA certificate
• Manufacturers guarantee: 1 year material and workmanship
● Included:
M212A: Digital multimeter with battery, cable set and operating instructions
M212D: METRAmax 12 Set 1 measuring case, same as M212A in HC20 carrying case
with WZ12A clip-on ammeter
● For optional accessories refer to the table on page 28.
METRA HIT 1A, 2A
Type
Data Sheet No.
METRAmax 12
3-348-831-03
Article Number
M212A
METRAmax 12 Set 1
3-348-831-03
M212D
F823 ever-ready case
–
GTY3172097P01
F829 carrying pouch
–
GTZ3301000R0003
METRA HIT 1A: Analog Multimeter, Basic Model for Hobby and Work
METRA HIT 2A: Analog Multimeter for Electrical Applications, Class 2.5
METRA HIT 1A: basic analog multimeter for training and hobby applications, compact time-tested design
• Voltage measurement: 0...0.15/ 0...0.5 V=, 0...1.5/5/15/50/150/500 V=/∼
• Input resistance: 20 kΩ/V=, 4 kΩ/V∼
• Current measurement: 0 ...50 μA=, 0...0.5/5/50/ 500 mA /5 A=/∼
• Resistance measurement: 1 Ω ... 1 MΩ (4 ranges)
• Level: -15 ...+56 dB (6 ranges)
• Dimensions (W x H x D): 92 x 126 x 45 mm
• Weight: approx. 0.25 kg without battery
• Battery: 11.5 V, IEC LR 6 (AA mignon)
• Manufacturers guarantee: 1 year material and workmanship
METRA HIT 2A: basic analog multimeter for electrical applications, class 2.5, compact time-tested design
• Voltage measurement: 0...0.15/ 0...0.5 V=, 0...1.5/5/15/50/150/500 V=/∼
• Input resistance: 20 kΩ/V=, 4 kΩ/V∼
• Current measurement: 0...50 μA=, 0...1.5/15/150 mA/ 1.5 /15 A=/∼
• Resistance measurement: 1 Ω...1 MΩ (4 ranges)
• Level: -15...+56 dB (6 ranges)
• Accuracy: class 2.5
• Dimensions (W x H x D): 92 x 126 x 45 mm
• Weight: approx. 0.25 kg without battery
• Battery: 11.5 V, IEC LR 6 (AA mignon)
• Manufacturers guarantee: 1 year material and workmanship
● Included:
M100A: Analog multimeter with operating instructions (without battery and cable set)
M101A: Analog multimeter with operating instructions (without battery and cable set)
● For optional accessories refer to the table on page 28.
18
Type
Data Sheet No.
Article Number
METRA HIT 1A
–
M100A
METRA HIT 2A
–
M101A
F809 ever-ready case
–
GTY3172083P01
GH185 protective rubber cover
–
GTY3171185P01
Made in Germany
Handheld Analog Multimeters
METRAmax 2
Analog Multimeter for Training Applications
The METRAmax 2 hand-held multimeter was developed in cooperation with a renowned German supplier of training
systems and fulfills all of the demands placed upon contemporary vocational training.
Thanks to exceptional overload capacity, a selectable scale zero point at left or center and automatic battery cutoff, this
instrument is not only well suited for training, but rather for balancing and service work as well.
•
•
•
•
•
•
•
•
Voltage measurement: 0...100/300 mV/1 V=, 0...3/10/30/100/300 V=/∼
Current measurement: 0...100 μA/1/10/100 mA/1 /3 A =/∼
Zero point: left / center
Accuracy: class 2 =/3 ∼
Dimensions (W x H x D): 100 x 140 x 35 mm
Weight: approx. 0.3 kg with battery
Battery: 9 V flat cell battery, IEC 6 LR 61 (6 F 22)
Manufacturers guarantee: 1 year material and workmanship
● Included:
M102A: Analog multimeter with battery and operating instructions (no cable set)
● For optional accessories refer to the table on page 28.
METRAmax 3
Type
Data Sheet No.
Article Number
METRAmax 2
3-348-792-01
M102A
Cable set for METRAmax KS14
–
Z110A
F841 carrying pouch
–
Z104A
GH19 protective rubber cover
–
Z104B
NW10A shunt resistor
–
GTZ0156000R0001
Analog Multimeter for Training Applications, and for Use in the Electrical Trades
The METRAmax 3 analog multimeter is an inexpensive, handy multimeter without amplifier stage with an integrated
circuit breaker for current measuring circuits. Good overload protection is provided in the voltage ranges as well by
means of generous dimensioning and high performance PTC thermistors.
•
•
•
•
•
•
•
•
Voltage measurement: 30/300/600 V=/∼
Current measurement: 0.3/ 3 /15 A=/∼
Resistance measurement: 1 Ω ... 500 kΩ
Protective Conductor
Accuracy: class 2.5
Dimensions: 100 x 140 x 35 mm, weight: approx. 0.3 kg with battery
Battery: 11.5 V, IEC LR 6 (AA mignon)
Manufacturers guarantee: 1 year material and workmanship
● Included:
M103A: Analog multimeter with battery and operating instructions (no cable set)
● For optional accessories refer to the table on page 28.
Made in Germany
Type
Data Sheet No.
Article Number
METRAmax 3
3-349-117-03
M103A
Cable set for METRAmax KS14
–
Z110A
F841 carrying pouch
–
Z104A
GH19 protective rubber cover
–
Z104B
NW10A shunt resistor
–
GTZ0156000R0001
19
Folding Digital/Analog Multimeters
METRAport ®32XS, 32S
3¾ place (32XS) or 4¾ place (32S) Folding, Universal TRMS Multimeter
with “Auto-Fuse”
Folding digital multimeter for universal use in general electrical and electronics applications, as well
as for automotive service. Ideal reading angle adjustment thanks to tilt stand. When suspended from
the neck strap, both hands are free for performing measurements. The instrument is switched off
automatically when folded closed, and the display and the control panel are protected against damage.
Automatic shutdown in the event of overcurrent minimizes maintenance costs and reduces downtime.
• Precision multimeter
• Resolution, METRAport 32XS: 100 μV, 100 nA, 100 mΩ, METRAport 32S: 10 μV, 10 nA, 10 mΩ
• TRMS measurement for VAC and IAC to 1 kHz
• Voltage measurement: 300 mV/3/30/300/600 V /∼
• Direct current measurement via transformer or current sensor with voltage output:
300 μA/3/30/300 mA/15 A /∼
• Resistance measurement: 300 Ω /3/30/300 kΩ/3/30 MΩ
• Frequency measurement: 300 Hz/3/ 100 kHz
• Capacitance measurement: 30/300 nF/ 3/30/300/3000/30000 μF
• Measured value storage and Min-Max recording, indication for overload and blown fuse
• Temperature measurement with automatic Pt sensor recognition: Pt100 or Pt1000
• Automatic and manual measuring range selection
• 20 mm digital display with additional analog scale
• Dimensions (W x H x D): 146 x 118 x 44 mm, approximate weight: 450 gr. including batteries
• Battery: 2 ea. 1.5V IECLR 6 (AA mignon)
• DKD certificate
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration
(depending upon application)
● Included:
M234C: Digital multimeter with carrying strap, batteries, KS17 cable set,
operating instructions, DKD calibration certificate
M234A: Digital multimeter with carrying strap, batteries, KS17 cable set,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
METRAport ® 3A
Type
Data Sheet No.
Article Number
METRAport 32XS
3-349-105-03
M234C
METRAport 32S
3-349-105-03
M234A
F822 carrying pouch
–
GTY3172095P01
Folding Analog Multimeter for Demanding Applications
Folding multimeter with analog display and 46 measuring ranges for universal use in process
engineering, electronics and electrical applications, testing, R&D, service and training in accordance
with EN 61010-1/DIN VDE 0411 part 1 1
• For measurement of voltage, current, resistance and level
• With reflective scale, accuracy class: 1.5 =
• High 10 MΩ input resistance for load-free voltage measurement
• Automatic battery cutoff when instrument is folded closed
• Scale can be tilted with folding lid which also provides protection during transport
• Overload protection in all ranges: 250 V~ (except for 10 A range)
• Voltage measurement:
9 measuring ranges each for direct and alternating voltage, 100 mV / 300 mV / 1 V / 300 V / 1000 V
• Power supply: commercially available 9 V battery, service life: 500 hours
• 10 measuring ranges each for AC and DC, 10μA / 100 μA / 1 A / 10 A
• Resistance simulation, 5 measuring ranges: 1 Ω ... 20 MΩ / 1Ω ... 2 kΩ / Ω x 1 / Ω x 10 / Ω x 10k
• Power supply: 9 V battery per IEC6F22 (commercially available), service life: 500 hr.
• Recommended accessories: NA2-9/20 mains power pack (highly isolated)
• G fuse element (FF1.6 / 250G )
• Manufacturers guarantee: 1 year material and workmanship
● Included:
M113A: Analog multimeter with carrying strap, battery, KS17 cable set,
operating Instructions
● For optional accessories refer to the table on page 28.
20
Type
Data Sheet No.
METRAport 3A
–
Article Number
M113A
F822 carrying pouch
–
GTY3172095P01
Made in Germany
Resistance Measuring Instruments and Insulation Tester
METRA HIT 27M / 27EX
Precision Milliohmmeter and 4¾ Place Multimeter (27M) or
Milliohmmeter for Use in Potentially Explosive Atmospheres (27EX)
METRAHit 27M: compact milliohmmeter plus multimeter and thermometer. Very well suited for on-site service, as well
as for a wide variety of laboratory tasks.
In addition to general low-resistance measurements, applications include: measurement of low-value contact
resistance at welded and riveted connections, as well as on aircraft outer skins (lightning protection and wick test)
• 3.000 mOhm to 300.00 mOhm with 1 A measuring current and 30.00 mOhm to 30.00 Ohm with 200 mA
measuring current
• Kelvin connection (4-wire measurement) − resistance measurement from 300 Ohm to 30 MOhm
• Voltage measurement from 3 to 600 V DC and 3 to 600 V AC − with ±30,000 digits
• Frequency measurement from 300 Hz to 3 kHz
• DATA hold memory for up to 1200 measured values − continuity and diode testing − overload protection
• CSA certificate − DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
METRA HIT 27EX: compact milliohmmeter for measuring low-value contact resistance on aircraft outer skins (lightning
protection, wick test), as well as for general low value resistance measurements inside and outside of potentially
explosive atmospheres
• Measuring ranges: 30 mΩ, 300 mΩ, 3 Ω, 30 Ω − resolution: 10 μΩ
• Measuring method: Kelvin connection (4-wire measurement)
• DATA hold memory: 1200 measured values
• EX designation: Ex II 2 G EEx ia IIA T4 − prototype test certificate: INERIS 05ATEX0040
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M227A: Digital multimeter with GH18 protective rubber cover, KS17S cable set,
operating instructions, DKD calibration certificate
M227D: Milliohmmeter with KC27 Kelvin probe, KC4 Kelvin clip, 8 type Z206E rechargeable NiMH
batteries, protective rubber cover, HC30 hard case, operating instructions,
DKD calibration certificate
● For optional accessories refer to the table on page 28.
Z206D: NiMH quick charger without batteries for type Z206E EX approved rechargeable batteries
➲ See page 91 for training seminar: GTT1219B
METRA HIT 27I/27AS
Type
Data Sheet No.
METRA HIT 27M
3-349-206-03
Article Number
M227A
METRA HIT 27EX
3-349-335-03
M227D
NiMH quick charger, EX
3-349-335-03
Z206D
4 rechargeable NiMH batteries, EX approved
3-349-335-03
Z206E
Precision Milliohmmeter, Insulation Tester and 4¾ Place Multimeter
In addition to a milliohmmeter and a multimeter, an insulation tester has been integrated into the METRAHit 27I for measurements up through the giga-ohm range. Especially where service and repairs in the field of aviation technology are
involved, the instrument can be used in a broad range of applications.
• Insulation resistance measurement: 30 MOhm to 3 GOhm
• With selectable test voltages: 50V, 100V, 250V, 500V
•
•
•
•
•
•
•
•
•
Milliohmmeter:
3.000 mOhm to 300.00 mOhm with 1 A measuring current and 30.00 mOhm to 30.00 Ohm with 200 mA measuring current
Kelvin Connection (4-wire measurement)
Resistance measurement from 300 Ohm to 30 MOhm
Voltage measurement from 3 to 600 V DC and 3 to 600 V AC with ± 30,000 digits − frequency meas. from 300 Hz to 3 kHz
DATA hold memory for up to 1200 measured values − continuity and diode testing
Overload protection − CSA certificate − DKD calibration certificate as standard feature
LCD panel with background illumination − furnished with 3 rechargeable NiMH batteries and charger as standard equipment
Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
METRAHit 27AS: avionics set with extensive accessories and software in carrying case
● Included:
M227B: Digital multimeter with GH18 protective rubber cover, rechargeable NiMH batteries,
NA4/500 charger, KS17S cable set, operating instructions, DKD calibration certificate
M227C: Same as M227B in HC30 measuring case with KC 4 Kelvin clip set (2 pieces),
KC27 Kelvin probes (2 pieces) and BD pack including adapter, cable and
METRAwin10 software
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
Made in Germany
Type
Data Sheet No.
METRA HIT 27I
3-349-206-03
Article Number
M227B
METRA HIT 27AS
3-349-206-03
M227C
VL15 extension cable, 15 m
−
Z110I
21
Resistance Measuring Instruments and Insulation Tester
AS-i Bus Testers
METRAmax 6
Analog Resistance Measuring Instrument with Rough Capacitance Measurement
Resistance measuring instrument with analog display for use in the plant, on service calls and for installation work
• Measuring method: current measurement
• Large variety of measuring ranges from 0.05 Ω to 1 MΩ (5 ranges)
• Ranges for rough capacitance measurement from 0 to 30000 μF
• Integrated buzzer for continuity testing
• Rugged moving-coil mechanism with spring loaded bearing jewels allows for use under adverse operating conditions
• Dimensions (W x H x D): 100 x 140 x 35 mm
• Weight: approx. 0.3 kg without battery
• Battery: 11.5 V, IEC LR 6 (AA mignon)
• Manufacturers guarantee: 1 year material and workmanship
● Included:
Resistance measuring instrument with operating instructions
● For optional accessories refer to the table on page 28.
METRA HIT 1 ASi
Type
Data Sheet No.
Article Number
METRAmax 6
–
GTM3060000R0001
F825 ever-ready case
–
GTY3172100P01
ASi Bus Tester – Diagnosis and Addressing Tool
The handy, rugged addressing and diagnosis tool for initial start-up, maintenance and service of ASi systems offers the
following functions:
• Read-out of slave addresses 0 through 31, A and B, without scrolling including clear-cut, full LCD
• Read-out of slave IO and ID codes (including extended ID codes 1 and 2)
• Standard addressing mode and extended addressing mode per AS-i version 2.1
• Programmable ID code 1
• Function test for slaves, including analog slaves with profile 7.2 (7.3 in preparation)
• Recognition of complete arrays of system components
• Storage, diagnosis and PC gateway functions
• Data transmission and management, as well as documentation of system parameters with optional software
• Connection with jack plugs
Included:
• METRA HIT 1ASi: AS-i addressing device and tester with GH18, batteries and KS31A
• Set 1ASi: AS-i addressing device and tester with batteries, GH18, KS31C, BD232 and ASi-doc documentation software in
HC30 hard case
● Included:
M235A: AS-i addressing device and tester with protective rubber cover, batteries and
addressing cable with jack plug
M235C: AS-i addressing device and tester with protective rubber cover, batteries,
KS31C connector cable set (M12 female to M12 male), BD232 interface adapter and
ASi.doc-win documentation software in HC30 case
● For optional accessories refer to the table on pages 22 and 23.
Bus Tester Accessories
KS31A
3-349-108-03
Article Number
M235A
Set 1ASi
3-349-108-03
M235C
Designation
Article Number
Battery set (4 ea. rechargeable NiMH batteries, 1600 mAh) and charger
Z206B
Connector cable set (banana plug to jack plug)
Z231A
KS31B
Connector cable set (banana plug to M12)
Z231B
KS31C
Connector cable set (banana plug to jack plug) and module base with addressing socket
Z231C
KS36E
ASi-Pack 1
HC20
22
Data Sheet No.
Accessories for METRA HIT ® 1 ASI
Type
1ASi battery set
Type
METRA HIT 1ASi
1 ea. AS-i ribbon cable pick-off with M12
Z236E
Documentation and management set for ASi bus including ASi-Access, BD232, RS 232 cable
Z231D
Hard case for METRAHit 1ASi
Z113A
Made in Germany
AS-i Bus Testers
Accessories and Software for AS-i Bus Testers
METRAtest 36 ASi
AS-i Bus Testers
Measuring, test, monitor and addressing device for ASi bus and ASi slaves for initial start-up and troubleshooting
•
•
•
•
•
•
•
•
•
•
•
•
•
Simple menu-driven operation with function keys and matrix display
Measurement of bus characteristics (voltage, current consumption)
Recognition of data protocol errors (e.g. duplicate addresses)
Master mode operation for ASi bus
Programming and parameters configuration for ASi slaves
PC gateway function
Monitoring function with address trigger for indication of error frequency
Tool kit and extensive accessories included
Complete display of all parameters and addresses
Compatible with existing installations and latest ASi standard 2.11
Integrated 128 kB memory for saving entire systems, also allows for copying functions
Firmware can be downloaded from a PC via IrDA interface: simplifies later upgrades.
Inexpensive documentation and management software (ASi-doc or ASi-access, optional) streamlines documentation,
planning and start-up
● Included:
M236A: AS-i addressing device and tester with neck strap, measurement cable,
KS36A connector cable set, ground cable, NA 0100S charger, and HC30 case
M236B: Same as M236A but with additional, extensive connector accessories
(module base with addressing socket, KS36A, B, C, D, E connector cable sets),
IrDA 0100S interface adapter and ASi-access software
● For optional accessories refer to the table on page 23.
Bus Tester Accessories
Data Sheet No.
Article Number
3-349-106-03
M236A
Set 36 ASi
3-349-106-03
M236B
Accessories for METRAtest 36 ASi
Type
NA 0100S
Type
METRAtest 36ASi
Designation
Charger for 36A rechargeable battery pack
Article Number
Z501D
KS36A
Connector cable set (M12 to jack plug)
Z236A
KS36B
Connector cable set (M12 female to M12 male)
Z236B
KS36C
Connector cable set (M12 male to M12 male)
Z236C
KS36E
1 ea. AS-i ribbon cable pick-off with M12
Z236E
IrDa 0100S
Interface adapter to RS 232 for METRAtest 36A
Z501C
ASi-Pack 1
Documentation set for AS-i bus with BD232, RS 232 cable and ASi-doc (for METRA HIT 1 ASi)
Z231D
Bus Tester Software
Software for METRA HIT ® 1 ASI and METRAtest 36 ASi
Type
Designation
Article Number
ASi.doc-win
Documentation software for AS-i bus
Z710Q
ASi-access
Documentation and management software for AS-i bus
Z710J
Made in Germany
23
Calibrators
METRA HIT 28c light
Handheld Calibrator with Current Measuring Instrument for Process Engineering
The METRA HIT 28c light calibrator functions as a precision calibrator and simulation device for electrical and physical
quantities. As a handheld instrument, it is suitable for precise, on-site calibration and inspection tasks, as well as for
test department and laboratory work.
Thanks to its diverse functions, the highly flexible instrument can be used in process engineering, control room and
equipment fabrication, general measuring technology and many other applications.
As a system component it can be used in calibration systems for calibrating measuring transducers, buffer amplifiers,
transmitters, temperature measuring instruments and recording instruments, controllers, signaling devices and
indicators.
With plugged on BD232 or USB-HIT interface adapter, complete calibration procedures and measuring point oriented
calibration cycles can be transferred from a PC, and stored and accessed by simply pressing a key.
The calibrator setup procedure can thus be significantly shortened, and erroneous settings can be avoided.
METRAwin 90-2 software simplifies programming, controls data transfer to the calibrator, receives measurement data
of any interconnected multimeter from the output of a transducer and executes a comparison of the targeted and the
actual situation. Acquired values can be printed out as a calibration report by the PC.
• Universal calibrator, simulator with easy operation
• Measuring functions: mA / mV ... V / °C (Pt100/1000, Ni100/1000, thermocouples J, L, T, U, K, E, S, R, B and N) / 5 ... 2000 Ω
• Frequency and pulse run generator: 1 Hz ... 1000 Hz
• Absolute and percentage (scaled) read-out
• Ramp and staircase functions
• Procedures memory
• Interface and METRAwin 90-2 calibration software
• Transmitter simulator (sink: 0 ... 24 mA)
• DKD calibration certificate included
• Rugged, EMC compliant design
• Dimensions: 84 x 185 x 35 mm, weight: 0.4 kg with batteries
• Batteries: 3 ea. 1.5 V IEC LR 6 (AA mignon)
• Manufacturer’s guarantee: 3 years material and workmanship, 1 year for calibration
● Included:
M231A: Calibrator with batteries, KS17 cable set (yellow/black), GH18 protective rubber cover,
operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
METRA HIT 28C
Type
Data Sheet No.
Article Number
METRA HIT 28c light
3-349-316-03
M232A
Calibrator, Multimeter and Milliohmmeter for Process Engineering
Process engineers can use the METRAHit 28C as a calibrator and a multimeter simultaneously, e.g. in order to simulate
sensor conditions at the input of a transmitter while measuring and saving the output signal. If the METRAHit BD232
plug-in infrared interface adapter is attached to the instrument, measurement and calibration results can be uploaded
to a PC, where they can be recorded and printed out as a calibration report.
The multimeter can also be used as a data logger.
Software allows for convenient analysis and display of measurement data, and can be used to create, upload and
download calibration procedures, as well as for the generation of calibration certificates.
• Measuring functions: mA, mV.. V, 30 ... 2000 Ω, °C, Pt100/1000, Ni100/1000, thermocouples (J,L,T,U,K,E,S,R,B,N)
• Dual mode – simultaneous encoding and measuring (U/I)
• Measuring and encoding in absolute terms and as percentage (scaled)
• Memory for calibration procedures and results
• Frequency and pulse run generator
• Ramp and staircase functions
• Interface and METRAwin 90-2 calibration software
• Transmitter simulator (sink 0 ... 24 mA)
• Rugged, EMC compliant design
• Infrared interface
• Precision multimeter (V, A, Ω, F, Hz, °C/°F) 300,000 digits and triple display, CAT II at 600 V
• Milliohmmeter, 4-wire connection with 0.01 mΩ resolution
• DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M231A: Calibrator with batteries, KS17 cable set (yellow/black), KS17 cable set (red/black),
GH18 protective rubber cover, operating instructions, DKD calibration certificate
● For optional accessories refer to the table on page 28.
24
Type
Data Sheet No.
Article Number
METRA HIT 28C
3-349-098-03
M231A
Made in Germany
Calibrators
CP28 Calibrator Pack
Mobile Calibration System
Fully automated calibration of measuring transducers, transmitters, buffer amplifiers and measuring modules is
possible in just a matter of seconds – including certificate generation – with the CP28 calibrator pack.
The CP2 calibrator pack includes everything required for an automated calibration system:
• METRAHit 28C calibrator
• BD232 interface adapter
• RS 232 interface cable
• KC2 Kelvin clip
• 1ASi battery set
• KY95-1 alligator clips
• METRAwin 90-2 for automatic read-out of calibration values
• METRAwin10/METRAHit for precision measurement of values read out from the object to be calibrated
• DKD calibration certificate as standard feature
• Manufacturer’s guarantee: 3 years material and workmanship, 1 year for calibration
● Included:
M231C: METRA HIT 28C with batteries, KS17 cable set (yellow/black), KS17 cable set (red/black),
GH18 protective rubber cover, operating instructions, DKD calibration certificate plus
METRAwin10 and METRAwin 90-2 software, RS 232 interface cable,
BD232 interface adapter, KC4 Kelvin clips, HC30 case and 1ASi battery set
● For optional accessories refer to the table on page 28.
Type
Data Sheet No.
Article Number
CP28 calibrator pack
3-349-098-03
M231B
Technical Data – METRA HIT 28C light and METRA HIT 28C Calibrators
Function
Instrument ➤
➤
Calibration:
Measuring:
METRA HIT 28c light
Range
Resolution
Voltage = 0...300 mV/3/10/15 V
0.01...1 mV
METRA HIT 28C
Intrinsic Error
Range
Resolution
± 0.05%+ 2 mV 0...300 mV/3/10/15 V
Intrinsic Error
0.01...1 mV
± 0.05% + 2 mV
Current =
0...24 mA
1 μA
± 0.05%+ 2 μA
0...24 mA
1 μA
± 0.05% + 2 μA
Resistance, 2-wire
5...2000 Ω
0.1 Ω
± 0.05%+ 0.2 Ω
5...2000 Ω
0.1 Ω
± 0.05% + 0.2 Ω
Resistance, 4-wire
0...2000 Ω
0.1 Ω
± 0.05%+ 0.2 Ω
0...2000 Ω
0.1 Ω
± 0.05% + 0.2 Ω
Thermocouples
– 200...1800° C
0.1 K
± (0.1% input + 0.5 K)
– 200...1800° C
0.1 K
± (0.1% input + 0.5 K)
Resistance thermometers
– 180...850° C
0.1 K ±(0.1% input + 0.4/0.5 K)
– 180...850° C
Frequency
1 kHz
± 0.05%+ 3 digits
1 kHz
0.1...8 Hz
0.1 K ±(0.1% input + 0.4/0.5 K)
0.1...8 Hz
± 0.05% + 3 digits
Voltage
–
–
–
0...300 mV/600 V 1 μV (10 μV)
± 0.05% + 15 digits
Current =
–
–
–
0...3/30/300 mA 10 nA...1 μA
± 0.05% + 15 digits
Current ~
–
–
–
0...3/30/300 mA 10 nA...1 μA
± 0.05% + 5 digits
Resistance, 2-wire
–
–
–
0...300 Ω/30 MΩ 1 mΩ/0.1 kΩ
± 0.07% + 15 digits
Resistance, 4-wire
–
–
–
0...30 mΩ/30 Ω 10 μΩ/1 mΩ
± 0.5% + 5 digits
Thermocouples
–
–
–
-200 ... 1800ξ C
Resistance thermometers
–
–
–
–200 ... 850ξ C
Capacitance
–
–
–
0...3 nF/30 μF
1 pF/10 nF
± 1% + 5 digits
Frequency
–
–
–
0...300 Hz/30 kHz
0.01...10 Hz
± 0.05% + 5 digits
Diode test at 1 mA
–
–
–
0...3 V/15 V
0.1 mV
± 0.5% + 5 digits
Made in Germany
0.1 K
± 0.2...0.8%+ 3 digits
0.1 K ± 0.25 K/0.5% + 3 digits
25
Power Meters
MAVOWATT 4
Multiple Power Meter
The multiple power meter allows for direct measurement of DC power as well as RMS power measurements for
single-phase alternating current and balanced load three-wire, three-phase current.
• Determination of reactive power
• Measurement of phase-to-phase voltage(s)
• Ideal instrument for manufacturing, service and installation
• Phase sequence indicator
• cos ϕ measurement
Technical Data:
Direct current
12.5 kW
Single-phase alternating current
12.5 kW (active power)
3-wire, 3-phase, balanced load
Nominal current
25 kW (active power) / 25 kVar x 3 (reactive power)
0.25 A / 0.01 A / 5 A / 1 A
Nominal voltage
50 / 100 / 250 / 500 V
Frequency Range
10 Hz ... 400 Hz
AC-DC voltage measurement
50 / 100 / 250 / 500 V
AC-DC current measurement
0.25 A / 0.01 A / 5 A / 1 A
Accuracy class
1.5 (2.5 P−, U, I)
Power Supply
2 ea. 9 V flat cell, IEC 6 F 22, 6LF22 or 6LR61
Dimensions (W x H x D)
110 x 181 x 62 mm
Weight
● Included:
METRA HIT 29S
0.8 kg
GTM3033000R0001: Multiple power meter with batteries and operating instructions
Type
Data Sheet No.
Article Number
MAVOWATT 4
3-348-801-03
GTM3033000R0001
KS28 cable set
–
GTY3620065P0001
5¾ Place Precision TRMS Multimeter, Power Meter and Power Disturbance Measuring
Instrument with Data Logger
Precision multimeter, power multimeter and power disturbance measuring instrument with integrated memory for
universal use in the field of energy electronics, and for high bandwidth electronics from 16 Hz to 100 kHz and
TRMS AC /TRMS AC+DC
• Triple display: ± 310,000 digits
• Minimal intrinsic error: ± (0.02% + 10 digits for V DC )
• Measuring functions: 300 mV to 1000 V, 300 uA to 100 A, 300 Ohm to 30 MOhm, 3 nF to 30 mF, dBV, Hz,
°C and °F (Pt100/Pt1000, type K and J thermocouples with reference junction)
• W, VA, VAr, Wh, VAh, peak load profile, power disturbance measurement, power disturbance recording
• Patented automatic blocking sockets (ABS)
• IR Interface
• Continuity and diode testing
• Integrated 128 kB measured value memory, 0.5 s to 10 minute sampling interval
• Versatile trigger functions
• Min-Max measured value storage, DATA hold
• With cable set, protective rubber cover and DKD calibration certificate
• Optional METRAwin 10 software
• CSA certificate
• DKD calibration certificate as standard feature
• CAT IV at 300 V or CAT III at 600 V per IEC 61010-1
• Manufacturer’s guarantee: 3 years material and workmanship, 1 to 3 years for calibration (depending upon application)
● Included:
M229A: Digital multimeter with GH18 protective rubber cover, batteries, measurement cable set,
operating instructions, DKD calibration certificate
M229E: Same as M229A in HC30 carrying case with WZ12D current sensor, TF220 temperature
sensor and BD-Pack1 (BD232 interface adapter, cable, METRAwin 10 software)
● For optional accessories refer to the table on page 28.
➲ See page 91 for training seminar: GTT1219B
26
Type
Data Sheet No.
Article Number
METRA HIT 29S
3-348-866-03
M229A
METRA HIT 29S Set 1
–
M229E
KS29 safety cable set
–
Z229A
Made in Germany
Multimeter Accessories:Fuses – Consumable Materials
Pouches, Cases, Protective Rubber Covers
Fuses – Consumable Materials for Multimeters
Type
FF(UR)16A/1kVAC-DC
FF (UR)10A/1kV AC-DC
FF(UR)1.6A/1kVAC-DC
FF 1.6 A/700 VAC
FF 16 A/600 VAC
FF(UR)16 A/600 VAC
FF 630 mA / 700 V
FF 6.3 A / 500 V
FF1.6 A/700 VAC
FF16 A/600 VAC
FF 1A/380V (5 x 20)
T 16A/500V (6.3 x 32)
FF 1.6 A/700 VAC
FF 16 A/600 VAC
F500mA/250V
M125mA/250V
Designation
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuse link
Fuses, F1/F2 multimeter
Fuse, F3 calibrator
For Following Devices:
METRAHIT 24S ... 26S
METRAHIT X-TRA, PRO, 28S, 29S
METRAHIT 23S ... 26S, 27M/I, 28S, 29S
METRAHIT ONE/2A, METRAmax 12, METRAport 3A
METRAmax 14, METRAport 3A, METRAHIT 2A
METRAHIT ONE
METRAHIT 1A
METRAHIT 1A
METRAHIT ONE/2A, METRAmax 12, METRAport 3A
METRAmax 14, METRAport 3A, METRAHIT 2A
METRAport 32S/32 XS
METRAport 32S/32 XS
METRAHIT ONE/2A, METRAmax 12, METRAport 3A
METRAmax 14, METRAport 3A, METRAHIT 2A
METRAHIT 28C
METRAHIT 28C and 28c light
Shipped in
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Package of 10
Article Number
Z109B
Z109L
Z109C
Z109E
Z109A
Z109D
Z109J
Z109K
Z109E
Z109A
Z109H
Z109I
Z109E
Z109A
Z109F
Z109G
Overview of Pouches, Cases and Protective Rubber Covers for Multimeters
Type
Designation
HitBag
F809
F822
F823
F825
F829
F836
F840
F841
GH18
GH185
GH19
HC20
HC30
BASE/PRO/X-TRA
Cordura belt pouch
✔
Ever-ready case with cable compartment
–
Ever-ready case with cable compartment
–
Ever-ready case with cable compartment
–
Ever-ready case
–
Carrying pouch for METRAHIT and METRAmax
✔
Ever-ready case with cable compartment
✔
Ever-ready case for 2devices, 2adapters, accessories
✔
Carrying pouch
–
Protective rubber cover and carrying strap (green)
–
Protective rubber cover
–
Protective rubber cover
–
Hard case for 1 device, accessories
✔
Hard case for 2 devices, accessories
✔
ONE
✔
–
–
–
–
✔
✔
✔
–
–
–
–
✔
✔
Suitable for Device Type:
METRA HIT
22S ... 30M 16I/16T/16U 27M/27I 28C/28C light 1A/2A
✔
✔
✔
✔
–
–
–
–
–
✔
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
✔
✔
✔
✔
–
✔
✔
✔
✔
–
✔
✔
✔
✔
–
–
–
–
–
–
✔
✔
✔
✔
–
–
–
–
–
✔
–
–
–
–
–
✔
✔
✔
✔
–
✔
✔
✔
✔
–
METRAmax METRAport
2/ 3 6 12 32S, XS/3A
–
–
–
✔
–
–
–
–
–
–
–
✔
–
– ✔
–
✔ ✔ –
–
–
– ✔
–
–
–
–
–
–
–
–
–
✔ ✔ –
–
–
–
–
–
–
–
–
✔ ✔ –
–
–
–
–
–
–
–
–
–
GH18
GH185
HC20
HitBag
GH19
HC30
F829
F836
F809
F840
Made in Germany
Designation
Type
Cordura belt pouch
HitBag
Article Number
Z115A
Ever-ready case with cable compartment
F809
GTY3172083P01
Ever-ready case with cable compartment
F822
GTY3172095P01
Ever-ready case with cable compartment
F823
GTY3172097P01
Ever-ready case
F825
GTY3172100P01
Carrying pouch for 1device with GH18, sensor
F829
GTZ3301000R0003
Ever-ready case with cable compartment
F836
GTZ3302000R0001
Ever-ready case for 2devices, 2adapters, accessories
F840
GTZ3302001R0001
Carrying pouch
F841
Z104A
Protective rubber cover and carrying strap (green)
GH18
GTZ3212000R0001
Protective rubber cover
GH185
GTY3171185P01
Protective rubber cover
GH19
Z104B
Hard case for 1 device, accessories
HC20
Z113A
Hard case for 2 devices, accessories
HC30
Z113A
27
Multimeter Accessories – Overview
Type
Designation
Current Transformers
Shunt resistor, 3 A, 10 Ω, class 0.5, 100 mV/A, 600 V CATIV
Shunt resistor, 300 mA, 1Ω, class 0.5, 1 mV/mA
AC clip-on current transformer, 1 ... 200 A∼, 1mA/A
AC clip-on current transformer, 0.5 ... 20/200 A∼, switchable, 100/10 mV/A
AC clip-on current transformer, 15 ... 180 A∼, 1 mA/A
AC clip-on current sensor, 10 mA ... 100 A~, 1 mV/10 mA
AC clip-on current sensor, 1 mA ... 10 A/120 A∼, switchable, 1 mV/mA1 / 1 mV/A
Clip-on current transformer, 30 mA ... 150 A~, 1 mA/A
AC clip-on current transformer, 4 ... 500 A∼, 1 mA/A
AC clip-on current transformer, 0.5 ... 1000 A∼, 1 mA/A
AC clip-on current sensor, 1 mA ... 1/10/100/1000 A~, switchable, 1000/100/10/1 mV/A
AC clip-on current transformer, 1 ... 2000 A∼, 1 mA/A
DC-AC clip-on current sensor, 0.01 ... 30 A /... 20 A∼, 100 mV/A, with battery
DC-AC clip-on current sensor, 0.1...30/300 A /...20/200 A∼, switchable, 10/1 mV/A, battery
DC-AC clip-on current sensor, 0.4...60/600 A /...40/400 A∼, switchable, 10/1 mV/A, battery
DC-AC clip-on current sensor, 1...300/1000 A /...200/1000 A∼, switchable, 1 mV/A, battery
Ampflex AC current sensor, 5 ... 30 /300 A∼, switchable, 100/ 10 mV/A, with battery
Ampflex AC current sensor, 5 ... 1000∼, 1 mV/A, with battery
Ampflex AC current sensor, 5 ... 300/3000 A~, switchable, 10 mV/1 mV/A, with battery
Ampflex AC current sensor, 5 ... 1000/10000A~, switchable, 1 mV/0,1 mV/A, with battery
Voltage Probes
KS30
Probe for voltage measurement in power installations with up to 1000 V∼
HV3
High-voltage probe, 3 kV/3 V
HV30
High-voltage probe, 30 kV/30 V (for direct voltage only)
High Frequency Probe
Z3431-2
High frequency probe, 100 kHz ... 750 MHz, 0.25 ... 50 V∼
Temperature Sensors and Probes
TF400CAR
Dip-stick oil temperature sensor, Pt1000 class B, -50...+500° C, sensor: 3 mm dia. x 180 mm long
TF220
Pt1000 temperature sensor, class B, for measurement in gases and liquids, -50 ... +220° C
Z3409
Standard Pt100 sensor, class A, for surface and immersion measurements, -40 ... +600ξ C
TF550
Pt100 oven sensor, class B, for measurements in ovens, refrigerators etc., -50 ... +550ξ C
TS Chipset
10 miniature Pt100 sensors, class B (2 x 2.3 mm), adhesive, -50 ... +550° C
Z3431-3
Temperature probe with standard immersion sensor, type K thermocouple (NiCr-Ni), -20 ... +350° C
Z3431-9
Temperature probe without plug-in sensor, for type K thermocouple (NiCr-Ni), -20 ... +350° C
Z3431-4
Temperature probe without plug-in sensor, for type K thermocouple (NiCr-Ni), -25 ... +1150° C
Z3431-5
Standard plug-in immersion sensor, type K thermocouple, to +1100° C
Z3431-6
Plug-in surface sensor, type K thermocouple, to +850° C
Z3431-7
High temperature plug-in sensor tape, type K thermocouple, to +450° C
Z3431-8
Flexible, insulated plug-in sensor, type K thermocouple, to +250° C
Measuring Adapters
Z3450
Leakage current measuring adapter, DIN VDE 0107/DIN VDE 0750
SM16
Current measuring adapter, 16 A/230 V, for earth contact plugs
PMA16
Power measuring adapter (single-phase) 16 A/230 V, for earth contact plugs
EMA1
Energy measuring adapter for (3-phase) Ferraris meters
EMC Measuring Adapter
FMA1
METRA HIT field measuring adapter for electrical and magnetic fields
Measuring Accessories
KS17-ONE
Cable set for multimeter, 600 V CAT III 16 A
KS17-2
Cable set consisting of 1 pair of measurement cables, 1.5 m, 1000 V/CAT III, 600 V/CAT IV
KS17S
Cable set with 2 mm diameter steel tips and 120 cm cable, 1000 V / CAT III
KY94
Hook clips (1 pair) for KS17-2
KY95-1
Alligator clips (1 pair) for KS17-2, 300 V/CAT III
KY95-2
Alligator clips (1 pair) for KS17-2, 1000 V CAT III 19 A
KY96
Push-on lugs (1 pair) for KS17-2
Z3241
RS 232 interface cable, 2 m, (included with 1-Ch. Pack, 4-Ch. Pack and Z3231)
Kelvin Clips
KC4
Kelvin clips (1 pair) with normal terminals
KC27
Kelvin probes (1 pair) with stainless steel tips
Power Packs
NA4/500
Power pack, 230 V / 4.5 V, for METRA HITs manufactured through 2003
NA5/600
Power pack, 230 V / 5 V, for METRA HITs manufactured as of 2004
PC Interface
BD232
IR – RS 232 bidirectional interface adapter
BD-Pack 1
Single channel pack with BD232 adapter, RS 232 cable, METRAwin 10 and installation instructions
SI232 II
IR – RS 232 bidirectional memory adapter
1-Ch. Pack II Single channel pack with SI232 II adapter, RS 232 cable, METRAwin 10 and installation instructions
4-Ch. Pack II 4 channel pack with four SI232 II adapters, RS 232 cable, METRAwin 10 and installation instructions
USB-Hit
Bidirectional interface adapter, IR-USB
USB-Pack
Set consisting of USB-HIT interface adapter, USB cable and METRAwin 10 software
Software
METRAwin10 METRAwin 10/METRAHit – system software for METRAHIT multimeters
METRAwin90-2 Calibration software for controlling the METRAHIT 28C and for analysis of calibration results
METRA VIEW PC software
NW3A
NW300mA
WZ11A
WZ11B
WZ12A
WZ12B
WZ12C
WZ12D
Z3511
Z3512
Z3512A
Z3514
Z201A
Z202A
Z13B
Z203A
AF033A
AF11A
AF33A
AF101A
28
Suitable for Device Type:
METRA HIT
BASE PRO X-TRA ONE 22S 22M 23S 24S 25S 26S 26M
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
■
✔
■
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
■
✔
■
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
■
✔
■
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❍
✔
❍
✔
❍
✔
❍
✔
❍
✔
❍
✔
✔
❍
✔
✔
❍
❍
✔
✔
✔
✔
✔
✔
❍
❍
✔
❍
✔
✔
❍
❍
✔
❍
✔
✔
❍
❍
✔
❍
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❸
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
●
●
●
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Made in Germany
Multimeter Accessories – Overview
Suitable for Device Type:
METRA HIT
28S 29S 30M 16I 16T 16U 27M 27I 28C 28C light 1A 2A
Type
METRAmax
METRAport
2
3
6 12 32S 32XS 3A
Explanation of Symbols:
✔ = suitable for this device
❍ = suitable for this device under certain
circumstances
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❑
✔
❑
❑
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❑
❑
❑
❑
❑
❑
❑
❑
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❍
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❸
❸
✔
✔
❷
✔
❑
✔
❸
✔
✔
✔
✔
✔
✔
✔
❹
❺
❺
❹
❺
❺
❻
❻
✔
✔
❍
✔
❹
✔
✔
✔
✔
✔
✔
✔
✔
✔
❼
✔
✔
✔
✔
❼
✔
❼
✔
❼
❽
❼
❼
❾
❽
❾
❼
❾
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❺
✔
❺
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔ DC
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔ KS30
✔ HV3
✔ HV30
✔
✔
✔
✔
✔ Z3431-2
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❍
✔
❍
✔
❍
✔
❾
❾
❾
❻
❾
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❍
❶
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
❍
❍
✔
✔
✔
❍
❍
✔
✔
✔
❍
❍
✔
✔
✔
✔
✔
✔
Made in Germany
✩ = suitable for METRA HIT ONE plus
■ = suitable for higher current measuring
ranges
❑ = not for power measurement
❶ = to 1 kHz
❷ = to 120 A
❸ = to 300 A
❹ = as of 5 A
❺ = as of 50 A
❻ = as of 500 A
❼ = as of 2 A
❽ = as of 0.2 A
❾ = as of 20 A
TF400CAR
TF220
Z3409
TF550
TS Chipset
Z3431-3
Z3431-9
Z3431-4
Z3431-5
Z3431-6
Z3431-7
Z3431-8
Z3450
✔ SM16
PMA16
EMA1
FMA1
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
NW3A
NW300mA
WZ11A
WZ11B
WZ12A
WZ12B
WZ12C
WZ12D
Z3511
Z3512
Z3512A
Z3514
Z201A
Z202A
Z13B
Z203A
AF033A
AF11A
AF33A
AF101A
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔ KS17-ONE
✔ KS17-2
KS17S
✔ KY94
✔ KY95-1
✔ KY95-2
✔ KY96
Z3241
KC4
KC27
✔
✔
NA4/500
NA5/600
BD232
BD-Pack 1
SI232 II
1-Ch. Pack II
4-Ch. Pack II
USB-Hit
USB-Pack
METRAwin10
METRAwin90-2
METRA VIEW
29
Multimeter Accessories
NW3A / NW300mA
Shunt Resistors for Multimeters Without Current Measuring Function
The shunt resistors function as adapters for multimeters without their own current measuring function
(e.g. METRA HIT 22S, 16I, 16T, 16U).
● Usable with instruments specified in the overview on page 28
Clip-on Current Transformers
Clip-On Current Sensors
Type
Data Sheet No.
NW3A
–
Article Number
Z205B
NW300mA
–
Z205C
Current within conductors can be conveniently and safely measured with clip-on current
transformers and clip-on current sensors.
The following advantages result:
• The electrical circuit need not be interrupted − no electrical connection to the conductor.
• Measurement of current up to 2000 A − no multimeter overloading as a result of current surges.
● Usable with instruments specified in the overview on page 28
Type
WZ12A...D
Measuring Range
CAT at V
Wire Dia.
Trans. Ratio
Frequency Range
Intrinsic Error
± (% rdg. + mA)
AC-DC current sensors with voltage output, mV/A
WZ11A/B
Z201A
0.01 ... 30 A
0.01 ... 20 A~
III at 300
19 mm dia.
100 mV/A
DC ...400 Hz
...20 kHz
1%
Z202A
0.1 ... 30/300 A
0.1 ... 20/200 A~
III at 300
19 mm dia.
10 mV/A
1 mV/A
DC ...2 kHz
...10 kHz
1% + 0.03 A
1% + 0.3 A
Z203A
1 ... 300/1000 A
1 ... 200/1000 A~
III at 300
31 mm dia.
1 mV/A
DC ...10 kHz
1% +0.5 A
Z13B
0.5 ... 60/600 A
0.2 ... 40/400 A~
IV at 300
50 mm dia.
10 mV/A
1 mV/A
DC ...65 Hz
...10 kHz
1.5 %
2%
AC current sensors with voltage output, mV/A
Z3511
Z3514
Z3512
30
III at 300
15 mm dia.
0.1 mV/mA
45...65 ...500 Hz
1.5% +0.1 mA
WZ12C 0.001 ... 15 A AC
1 ... 150 A AC
III at 300
15 mm dia.
1 mV/mA
1 mV/A
45...65 ...500 Hz
3%+0.15 mA
2%+0.1 A
WZ11B 0.5 ... 20 A AC
5 ... 200 A AC
III at 600
20 mm dia.
100 mV/A
10 mV/A
30...48...65 Hz
...500 Hz
1 ... 3%
Z3512A 0 ... 1000 A AC
III at 600
52 mm dia.
1 mV 1 V/A
10...48...65 Hz
...3 kHz
0.2% ... 0.7%
Z13B
AC current transformers with current output, mA/A
Z202A
Z201A
WZ12B 0.01 ... 100 A AC
Z203A
WZ12A 15 ... 180 A AC
III at 300
15 mm dia.
1 mA/A
45...65 ...400 Hz
3%
WZ12D 0.03 ... 150 A AC
III at 300
15 mm dia.
1 mA/A
45...65 ...500 Hz
2.5% +0.1 mA
WZ11A 1 ... 200 A AC
III at 600
20 mm dia.
1 mA/A
48...65 ...400 Hz
1 ... 3%
Z3511
4 ... 500 A AC
III at 600
30 x 63 mm
1 mA/A
45...65 Hz
...1 kHz
3% +0.4 A
Z3512
0.5 ... 1000 A AC
III at 600
52 mm dia.
1 mA/A
30...45...65 Hz
...5 kHz
0.5% ... 0.7%
Z3514
1 ... 2000 A AC
III at 600
64 x 150 mm
1 mA/A
30...45...65 Hz
...5 kHz
0.5%
Type
Data Sheet No.
Article Number
WZ12A
3-349-017-03
Z219A
WZ12B
3-349-017-03
Z219B
WZ12C
3-349-017-03
Z219C
WZ12D
3-349-017-03
Z219D
WZ11A
3-349-017-03
Z208A
WZ11B
3-349-017-03
Z208B
Z3511
–
GTZ3511000R0001
GTZ3512000R0001
Z3512
–
Z3512A
–
Z225A
Z3514
–
GTZ3514000R0001
Z13B
3-349-085-03
Z213B
Z201A
–
Z201A
Z202A
–
Z202A
Z203A
–
Z203A
Made in Germany
Multimeter Accessories
Flexible Ampflex Current Sensors
Current Sensors for the Measurement of Alternating Current at Difficult to Access Locations
These sensors are suited for the measurement of alternating current at difficult to access locations.
They are highly insulated and can generally be switched at a ratio of 1:10 with a range selector.
The sensors can be operated within a frequency range of up to 20 kHz.
Maximum phase error is 2.5° at a frequency of up to 1 kHz.
Supply power is provided with a 9 V battery with a service life of approximately 150 hours.
● Usable with instruments specified in the overview on page 28
Voltage Probes
Type
Measuring Range
A DC, AC
CAT at V
Loop
Length
Trans. Ratio
Frequency Range
Hz
Intrinsic Error
± (% rdg. + mA)
AF033A
0.5 ... 30 A : 3 V
0.5 ... 300 A : 3 V
III at 1000
600 mm
100 mV/A
10 mV/A
10 ... 100
... 20 kHz
1% + 50 mA
1% + 5 mA
AF11A
0.5 ...
1 kA : 1 V
III at 1000
450 mm
1 mV/A
10 ... 100
... 20 kHz
1% + 2 mA
AF33A
0.5 ... 300 A : 3 V
0.5 ... 3000 A : 3 V
III at 1000
900 mm
10 mV/A
1 mV/A
10 ... 100
... 20 kHz
1% + 5 mA
1% + 2 mA
AF101A
0.5 ... 1 kA : 1 V
50 ... 10 kA : 1 V
III at 1000
1200 mm
1 mV/A
0.1 mV/A
10 ... 100
... 20 kHz
1% + 2 mA
1% + 1 mA
Type
Data Sheet No.
Article Number
AF11A
3-348-845-03
Z207D
AF033A
3-348-845-03
Z207A
AF33A
3-348-845-03
Z207B
AF101A
3-348-845-03
Z207C
For High-Voltage Measurements with a Multimeter
KS30:
Probe for up to 1000 V in power installations
• The high impedance KS30 voltage probe offers additional protection against overvoltages and operator error for
measurements at high energy voltage sources.
KS30
HV3:
3kV/3V high-voltage probe
• The HV3 probe is suitable for measurements of up to 3 kV. It simultaneously serves as a low pass filter for frequency
converter signals.
HV3
HV30:
30kV/30V high-voltage probe
• The HV30 high-voltage probe (VDE approved) can be used for safe measurement of direct voltages of up to 30 kV.
● Usable with instruments specified in the overview on page 28
HV30
High Frequency Probe
Type
Data Sheet No.
Article Number
KS30
–
GTZ3204000R0001
HV3
–
GTZ3431011R0001
HV30
–
GTZ3431001R0001
High Frequency Probe: 100 kHz to 750 MHz, 0.25 ... 50 V AC
In combination with a multimeter, the Z3431-2 high frequency probe allows for measurement of alternating
voltages with amplitudes of 0.25 V to 50 V within a frequency range of 100 kHz ... 750 MHz.
The probe rectifies alternating voltages at a ratio of 1:1.
The measuring instrument must have an input impedance of 10 MΩ.
● Usable with instruments specified in the overview on page 28
Made in Germany
Type
Data Sheet No.
Article Number
Z3431-2
–
GTZ3431002R0001
31
Multimeter Accessories
Temperature Sensors
Pt100/Pt1000 Temperature Sensors
Standard Z3409 sensor for surface and immersion measurements from -40° C to +600° C.
TF550 oven sensor for temperature measurements in ovens, refrigeration units etc. from -50° C to +550° C.
TF220 waterproof sensor for temperature measurements in gases and liquids, e.g. water temperature in washing
machines, oil temperature in automotive transmissions and air temperature in freezers and air conditioners.
TF400CAR dipstick oil temperature sensor for motor oil temperature measurement in automotive applications.
The TS chipset includes 10 miniature adhesive sensors for spot measurements at small measuring points within
a range of -50° C to +550° C.
Z3409
Type
I1
TF550
TF220
TF400CAR
I1
I2
2
TS Chipset
0.63
1.5
Temperature Probes
Z3431-3
TF550
TF220
Pt100
130
40
39
810
1000
1500
1500
2310
-40...+ 600 -50...+ 550 -50...+ 220 -50...+ 500
Class A
Class B
0.15 K
0.3 K
–
600: 1.35K
550: 3.1K
220: 1.4K
–
5s
8s
–
30 s
33 s
–
Strand, 2 ea. 0.35 square mm
–
PVC
V4A
Teflon
–
PVC
Glass
Teflon
–
Type
Data Sheet No.
Article Number
Z3409
–
GTZ3409000R0001
TF550
–
GTZ3408000R0001
TF220
–
0.25
Z102A
TF400CAR
–
Z102C
TS Chipset
–
GTZ3406000R0001
Pt100
2.3
10
-50...+ 550
0.4 K
550: 3.1K
0.3 s
15 s
0.25 dia./Ni-Pt
–
–
The Z3431-3 temperature probe is equipped with a permanently mounted, standard immersion sensor.
Measuring sensors Z3431-5 through 8 can be plugged into probes Z3431-4 and Z3431-9.
They are suitable for temperature measurements within a range of -25° C to + 1150° C.
The measurement output is connected to the mV/V measurement input at the multimeter.
Type
Z3431-3
Z3431-9
-25° C to +1150° C
NiCr-NiAl, type K thermocouple
± (0.5% rdg. + 0.5° C)
Accuracy (without sensor)
Required multimeter input impedance
± (1% rdg. + 1° C)
> 10 kΩ
1 mV / °C
Output voltage
Operating temperature
5° C ... 45° C
Dimensions (without sensor)
118 x 37 x 211 mm
Weight (without sensor)
140 gr.
Power Supply
•
•
•
•
Z3431-4
-20° C to +350° C
Sensor type
Z3431-8
TS Chipset
Temperature Probes (type K / NiCr-Ni)
Measuring range
Z3431-4/-9
TF400CAR
Pt1000
● Usable with instruments specified in the overview on page 28
I1
1.4
Z3409
Sensor element
Sensor element length (I1) mm
Sensor length (I2) mm
Temperature range, °C
Accuracy per DIN EN60751/IEC 751
Intrinsic error at 0°C
Intrinsic error for °C
Transient recovery, T90 water
Transient recovery, T90 air
Lead
Outer jacket
Insulation
110 gr.
1.5 V baby cell, 250 hour service life
Z3431-5: standard plug-in immersion sensor, to +1100° C
Z3431-6: plug-in surface sensor, to +850° C
Z3431-7: high-temperature plug-in sensor tape, to +450° C
Z3431-8: flexible, insulated plug-in sensor, to +250° C
● Usable with instruments specified in the overview on page 28
Z3431-7
Z3431-6
Z3431-5
32
Type
Data Sheet No.
Article Number
Z3431-3
–
GTZ3431003R0001
Z3431-4
–
GTZ3431004R0001
Z3431-5
–
GTZ3431005R0001
Z3431-6
–
GTZ3431006R0001
Z3431-7
–
GTZ3431007R0001
Z3431-8
–
GTZ3431008R0001
Z3431-9
–
GTZ3431009R0001
Made in Germany
Multimeter Accessories
Z3450 Leakage Current
Measuring Adapter
Leakage Current Measuring Adapter, DIN VDE 0107 / DIN VDE 0750
The Z3450 leakage current adapter is used with RMS multimeters for the measurement of contact voltage per
DIN VDE 0107, paragraph 10, and for the measurement of continuous leakage and patient auxiliary current per
DIN VDE 0750 part 1, IEC 601-1 and EN 60 601-1.1990.
● Usable with instruments specified in the overview on page 28
SM16/PMA16 Measuring Adapter
SM16
Type
Data Sheet No.
Article Number
Z3450
–
GTZ3450000R0001
Current Measuring Adapter / Power Measuring Adapter
PMA16
SM16 current measuring adapter for safe, trouble-free measurement of power consumption at consumers
connected to the mains with a plug. The attached cable with contact-protected connectors can be connected
directly to the current measurement sockets at the multimeter.
The PMA 1 power measuring adapter includes an additional, second cable for connection to the voltage path of
the METRA HIT 29S.
● Usable with instruments specified in the overview on page 28
METRA HIT EMA1
Type
Data Sheet No.
Article Number
SM16
–
GTM9070190E0002
PMA16
–
Z228A
Energy Measuring Adapter for Ferraris Meters
The EMA1 is a plug-in adapter for the METRA HIT 29S digital multimeter for energy measurement at Ferraris meters
without altering the electrical installation.
The EMA1 is an inexpensive, optimized accessory for acquisition, evaluation and optimization of energy curves in combination with
the METRA HIT 29S and METRAwin 10.
A METRA HIT 29S can be connected to a Ferarris meter via the EMA1 for the measurement and recording of 3-phase energy
curves. The meter pulse is acquired optically and is evaluated and recorded with a programmable factor. Recorded data are
displayed as a peak value curve with METRAwin 10 software.
• Dimensions (W x H x D): control unit : 97 x 135 x 39 mm, weight: 110 gr.
● Usable with instruments specified in the overview on page 28
METRA HIT FMA1
Type
Data Sheet No.
Article Number
EMA1
3-348-994-03
Z112A
E and B Field Measuring Adapter for Measurement of Low Frequency Alternating Fields
METRA HIT field measuring adapter for measuring and recording electrical and magnetic fields (recommended for use
with the following instruments: METRA HIT 26M, 28S and 29S)
• Compact, handy measuring instrument adapted to battery powered multimeters including METRA HIT 26S/26M ... 29S
• Suitable for short and long-term recording of EM fields and measurement data analysis at the PC in combination with
METRAHit 26M and 29S, and with the SI232 memory interface
• Orientation measurements in accordance with federal regulations (BIMSCHG)
• Testing for radiation at CRT monitor workstations in accordance with MPRII and TCO
• Easy to use
• High dynamic range assures reliable measurement values, even at 100% over-ranging
• Fluctuating field strengths can be recorded in combination with METRA HIT multimeters and METRAwin software,
and peak values can be analyzed
• Dimensions (W x H x D): control unit: 97x135x39 mm, weight: 210 gr. with batteries: 2ea.1.5 V IEC LR 6 (AA mignon)
Probe: 43x130x28 mm, weight: 130 gr.
● Usable with instruments specified in the overview on page 28
Made in Germany
Type
Data Sheet No.
Article Number
FMA1
3-348-854-03
Z108A
33
Multimeter Accessories
Measuring Accessories
Cable Sets, Clips, Interface cables and Extension Cables
A cable set with permanently mounted test probes and contact-protected angle plugs is available for safe
measurement.
Hook clips, alligator clips or push-on lugs can be attached to the test probes for special measuring tasks.
KY94
KY95-1
KY95-2
•
•
•
•
•
•
•
•
KS17-ONE cable set: 600 V CAT III 16 A (no photo)
KS17-2 cable set: consisting of 1 pair of measurement cables, 1.5 m, 1000 V/CAT III, 600 V/CAT IV
KS17S cable set: with 2 mm diameter steel tips and 120 cm cable, 1000 V / CAT III (no photo)
KY94 hook clips (1 pair) for KS17-2
KY95-1 alligator clips (1 pair) for KS17-2, 300 V/CAT III
KY95-2 alligator clips (1 pair) for KS17-2, 1000 V CAT III 19 A
KY96 push-on lugs (1 pair) for KS17-2
Z3241 interface cable: RS 232 interface cable, 2 m
● Usable with instruments specified in the overview on page 28
KY96
KS17-2
Z3241
Kelvin Clips
Type
Data Sheet No.
KS17-ONE
–
Article Number
Z110K
KS17-2
–
GTY3620034P0002
KS17S
–
Z110H
KY94
–
GTY3610094P01
KY95-1
–
GTZ3215000R0002
KY95-2
–
Z110J
KY96
–
GTY3610096P01
Z3241
–
GTZ3241000R0001
Kelvin Clips for Connecting Low-Impedance Resistors to Ohmmeters
Kelvin clips are used for connecting low impedance resistors (e.g. contact resistors, shunts etc.) to an ohmmeter
with 4-wire connection. This allows for compensation of cable resistance.
• KC4: Kelvin clips (1 set of 2 ea.) for 4-pole connection of low-resistance DUTs,
120 cm cable length, clip for connection to DUTs with diameters of up to 30 mm
KC4
• KC27: Kelvin probes (1 set of 2 ea.) with 2 stainless steel tips for 4-pole connection of low-resistance DUTs,
120 cm cable length
● Can be used with METRA HIT 30M, 27M and 27I (see overview on page 28)
KC27
NA4/500, NA5/600 Power Packs
NA4/500
Type
Data Sheet No.
KC4 Set
–
Article Number
Z227A
KC27 Set
–
Z227B
Mains Power Packs – Mains Adapters
Mains power packs for METRA HIT instruments allow for battery saving mains operation, in particular for continuous
measurements using multimeters with internal memory.
• NA4/500: Power pack, 230 V/4.5 V, for METRA HIT 22M, 26M, 27M, 27I, 28C, 28S, 29S and 30M
manufactured through 2003
• NA5/600: Power pack, 230 V/5 V/600 mA, for METRA HIT 27M, 27I, 28C, 28S, 29S and 30M
(due to modified plug connectors) manufactured as of 2004
NA5/600
34
● Usable with instruments specified in the overview on page 28
Type
Data Sheet No.
Article Number
NA4/500
–
Z218A
NA5/600
–
Z218F
Made in Germany
Multimeter Accessories: Interface Adapters, Memory Adapters
BD232
Interface Adapter for METRA HIT Multimeters
Can be snapped onto all METRA HIT multimeters. The infrared interface allows for electrically isolated data transmission
between PC and multimeter. Data transmission is indicated visually by means of two LEDs.
The BD232 interface adapter is especially recommended for measuring instruments with integrated memory (METRA HIT 22M,
26M, 29S, 30M). The BD-Pack 1 is available as a user-friendly complete package for single-channel operation. The package
includes the BD232 interface adapter, an RS 232 bus cable, METRAwin 10 software and installation instructions.
METRAwin 10 is used for data analysis and display (see page 36). It cannot be used for online recording with type SI232-II
adapters. In order to expand to 2, 3 or 4-channel operation, one BD232 is required for each channel, as well as additionally
required multimeters.
Accessories: Type Z3241 = RS 232 interface cable, 2 m, (included with 1-Ch. Pack, 4-Ch. Pack and Z3231)
• Dimensions: 135 x 97 x 39 mm
● Usable with instruments specified in the overview on page 28
➲ See page 91 for training seminar: GTT1219B
SI232 II
Type
Data Sheet No.
Article Number
BD232
3-349-026-03
GTZ3242100R0001
BD-Pack 1
3-349-026-03
Z215A
Z3241 interface cable
–
GTZ3241000R0001A1
Memory Adapter, Single-Channel / 4-Channel Memory Pack for METRA HIT Multimeters
Can be snapped onto all METRA HIT multimeters. Convert IR measurement data received from the instrument and
control signals received from the PC. Measurement data are recorded to the integrated memory with reference to realtime, and are transmitted to the PC after measurement has been completed. The 128 kB memory can be partitioned into
blocks as desired. The sampling interval can be set within a range of 50 ms to 10 minutes, or sampling can be
triggered in a signal dependent fashion for optimum memory usage.
The SI 232-II memory adapter is especially recommended for measuring instruments without integrated memory (METRA HIT
22S through 28S). The 1-Ch. pack is available as a user-friendly complete package for single-channel operation.
The pack includes the SI232 II memory adapter, an RS 232 bus cable, METRAwin 10 software and installation instructions.
METRAwin 10 is used for data analysis and display (see page 36).
In order to expand to 2, 3 or 4-channel operation, one SI 232-II is required for each channel, as well as additionally required
multimeters. The 4-Ch. Pack is recommended for simultaneous recording with 4 multimeters.
Accessories: Type Z3241 = RS 232 interface cable, 2 m, (included with 1-Ch. Pack, 4-Ch. Pack and Z3231)
• Dimensions: 135 x 97 x 39 mm, weight: approx. 0.25 kg with battery
• Batteries: 2 ea. 1.5 V IEC LR 6 (AA mignon)
● Usable with instruments specified in the overview on page 28
➲ See page 91 for training seminar: GTT1219B
USB-Hit
Type
Data Sheet No.
Article Number
SI232 II
3-349-026-03
GTZ3242020R0001
1-Ch. Pack II
3-349-026-03
GTZ3231020R0001
4-Ch. Pack II
3-349-026-03
GTZ3234020R0001
Z3241 interface cable
–
GTZ3241000R0001A1
USB Interface Adapter for METRA HIT Multimeters
Bidirectional IR-USB interface adapter for METRA HITs
Can be snapped onto all METRA HIT multimeters.
Data are transmitted from the multimeter to the adapter in a electrically isolated, bidirectional fashion, and to the USB interface for
PCs and laptops.
● USB pack: set consisting of USB-HIT interface adapter, USB cable and METRAwin 10/METRAHit software
● Usable with instruments specified in the overview on page 28
➲ See page 91 for training seminar: GTT1219B
New Image
Made in Germany
Type
Data Sheet No.
Article Number
USB-Hit
–
Z216A
USB-Pack
–
Z216B
35
Software for Measuring Instruments
METRAwin ® 10/METRA HIT
Measurement Data Recording and Parameters Configuring Software for METRA HIT Multimeters
Together with a BD232 interface adapter or an SI232 memory adapter, METRAwin 10/METRA HIT turns any METRA HIT
multimeter into a professional, PC-based universal recording system. Measured values are queried from the multimeters, managed at the PC and displayed as diagrams (up to 6 channels), XY diagrams (up to 4 channels) or in tabular form
(up to 10 channels) with METRAwin 10/METRAHit.
➀
In the online mode, measurement data are displayed live in diverse formats, e.g. at up to 4 virtual indicator instruments
or digital displays (with adjustable limit values).
High performance, online arithmetic functions allow for data analysis and evaluation.
The sampling interval can be set within a broad range depending upon device type and measuring function:
50 ms – 100 ms – 200 ms – 500 ms – 1 s ... 60 minutes online, or off-line to device memory to min. 0.5 ms (for
METRA HIT 29S).
Measurement data can be easily imported to other Windows PC applications such as Word and Excel via the clipboard.
METRAwin 10/METRA HIT software is included with the memory and interface adapter packs, and is not offered
separately.
The article number shown below includes updates.
Multimeter and Indicator Instruments (1 and 2)
Uploaded measured values are displayed at the screen both digitally and at an analog scale.
Data Logger (3)
Acquired measurement data are displayed chronologically at the screen in easy to read tabular form.
➁
Arithmetic Functions
Measurement data from different channels can be linked and processed with high performance arithmetic functions.
Yt Diagram (4 and 5)
Acquired measurement data are displayed at the screen as a time graph with a horizontal time axis, and are measured off with
two cursors. Stored signals can be expanded or compressed along amplitude or time axes (zoom function). The time axis can be
scaled in absolute time, or in relative measuring time.
Continuous Line Recorder
Up to 10 channels can be printed out continuously as a Yt line graph at a color printer.
➂
XY Diagram (6)
Acquired data are displayed as an XY graph and are measured off with the cursors.
As is the case with all display formats, all scales can be freely adjusted.
Sampling
Sampling can be started either manually (mouse click), automatically with an adjustable interval (50 ms to 1 hour) or as a function
of the signal with adjustable signal hysteresis (0 to 500 digits). The minimum sampling interval for devices with integrated memory
is 0.5 ms (see figure 6).
Data can be controlled with time and window triggers, and can be saved automatically as multiple data files.
System Requirements for METRAwin 10 as of Version 5.0
Operating system:
• MS Windows 95, 98, ME, NT, 2000 or XP
➃
➄
Hardware
• IBM compatible Windows PC, Pentium CPU or better with at least 32 MB RAM
• VGA monitor with a resolution of at least 800 x 600 pixels
• Hard disk with at least 20 MB available memory
• 3½" floppy disk drive for 1.4 MB floppies
• Microsoft compatible mouse or other pointing device
• A Windows supported printer if required
• 1 RS 232 serial port, COM1 ... COM8
Installation
A Setup.exe file is included on the floppy disk / CD ROM. Upon executing this file, METRAwin 10 software is installed in dialog with
the user. The installation directory and the program file folder can be selected as desired.
METRAwin 10 software is available in a variety of versions for various measuring instruments. These software variants can be
installed to the same directory, as long as only the last digit of the respective version numbers vary from each other (e.g. 5.04 and
5.01). However, the version with the highest number must be installed last.
Operation
METRAwin 10 software is equipped with an online help function. It includes operating instructions and explanations regarding
software, as well as communication with the measuring instrument.
➅
36
Type
Data Sheet No.
Article Number
METRAwin 10 Software Update
3-349-026-03
GTZ3240000R0001
Made in Germany
Software for Calibrators
METRAwin® 90-2
Calibration software for METRA HIT 18C and METRA HIT 28C
The handheld METRA HIT 18C or 28C calibrator with multimeter is transformed into a professional, PC-based calibration
system for measuring transducers, indicators and recording instruments with the help of METRAwin 90-2 and a BD232
interface adapter.
Calibration procedures are created with METRAwin software.
Specified analog values are transmitted from the PC via the BD232 adapter to the calibrator, and are fed to the device to be
calibrated from the analog output at the calibrator.
The analog output value from the device to be calibrated is then measured by the multimeter, and is returned to the PC for
evaluation via the interface.
If the measurement results remain within the specified tolerances, each consecutive calibration step is initialized automatically
until the entire procedure has been run.
Calibration data can be easily imported into other Windows applications (e.g. Word or Excel).
.
METRAwin 90F / FJ
Type
Data Sheet No.
Article Number
METRAwin 90-2
3-349-098-03
Z211A
METRAwin 90-F: Calibration Software for Fluke 55xx Benchtop Calibrators
METRAwin 90-FJ: Calibration and Adjusting Software
With METRAwin 90F, an IEEE-488 interface at the PC and a Fluke 5500A, 5520A or 5700A calibrator, a universal,
professional, automated closed-loop calibration system can be set up for METRA HIT series multimeters.
However, it is also suitable for universal use for calibrating analog and digital multimeters, recording instruments, power meters,
power measuring transducers, amplifier modules, transducers etc. Calibration procedures are generated with METRAwin90-F.
Specified analog values are transmitted from the PC via the IEEE 488 interface to the calibrator and are fed to the device to be
calibrated from the analog output at the calibrator. A BD232 adapter is coupled to the computer via an RS 232 cable for automatic
transmission of measurement results from the METRA HIT multimeter to the computer. In the case of measuring transducers, the
analog output value from the device to be calibrated is measured by a METRA HIT multimeter, and is returned to the PC for
evaluation via the interface. If the measurement results remain within the specified tolerances, each consecutive calibration step
is initialized automatically until the entire procedure has been run step by step.
• Automated calibration of METRA HIT ..S / ..M / ..A series handheld multimeters with infrared interface
• New: Adjustment of METRA HIT 22-29S/M hand-held multimeters via RS 232 interface
• Quick and simple generation, testing and documentation of calibration procedures
• Uncomplicated operation: even semiskilled workers can execute qualified calibration tasks.
• Outstanding applications flexibility with calibration signal feeding by means of key entry or via the interface
• Documentation printouts as standard calibration report, or as a user-specific certificate
• Dynamic data exchange with Microsoft Excel and Word
• Documentation includes all entries required for certificates in accordance with EN ISO 9000
• “Determination of measuring uncertainty” in accordance with DKD-3 after a specified number of measurements
• Specification of calculated measuring uncertainty in accordance with DKD-3 or TUR (test uncertainty ratio) included
in the report
Made in Germany
Type
Data Sheet No.
Article Number
METRAwin 90-F
–
Z211C
METRAwin 90-FJ
–
Z211F
37
Illuminance Meters
MAVOLUX 5032 C / ..B USB
Precision Digital Measuring Instrument for Measuring Illuminance in Lux or Footcandles
Digital luxmeter for inspecting light sources and street illumination, for monitoring the illumination of
workstations and public buildings, as well as sports and parking facilities, quality control for light sources,
quality assurance for the production of lamps and light fixtures. Very strong light can be measured with these
instruments without the use of any accessories. With a very high initial sensitivity of 0.01 lux, the MAVOLUX
5032 B USB is very well suited for measuring minimal illumination intensities as well, for example emergency
lighting. High precision in accordance with class B allows for use in certification applications and for inspection.
• Precision digital measuring instrument for measuring illuminance in lux or footcandles
• Luminance measurement in cd/m², or in footlamberts with luminance attachment as accessory
• Large measuring ranges − high resolution − classified in accordance with DIN 5032-7 and CIE no. 69
• The silicon photodiode is color corrected, i.e. its spectral sensitivity is matched to that of the human eye V(l). The
main difference between the MAVOLUX 5032C and MAVOLUX 5032B is the accuracy with which this matching has
been executed.
• Cosine correction for obliquely incident light
• Storage of up to 100 measured values − USB 1.1 interface
• Automatic and manual measuring range selection
• Rugged device design, simple operation
• Dimensions: basic device: 65 x 120 x 19 mm, probe: 31 x 105 x 30 mm, approx. weight: 200 gr. without battery
Cable between device and probe:
MAVOLUX 5032 C USB: coil cable, permanently attached, length: 1.5 m
MAVOLUX 5032 B USB: coil cable with plug, length: 1.5 m
Available for an additional charge: straight cable (not coiled), length: 3, 5 or 10 m
● Included:
Carrying case, CD ROM with software for displaying measured values, acquiring measured
values and device control, USB cable, battery and operating instructions
● Optional accessories: Luminance attachment, calculating disc for time/f-stop combinations and
other magnitudes for photography, adapter disc for measurements
at LCD monitors for the avoidance of obliquely incident light
● Factory certificate upon request
The traceability of measurement results to the national standard maintained by the PTB (German Federal
Institute of Physics and Metrology) is assured by means of the Wi 41G standard lamp.
The factory certificate is required for all applications for which measurements and testing in accordance
with legal directives and regulations are required.
MAVOLUX 5032 C USB
Measured Quantity
Illuminance
Luminance
(with attachment)
Measuring Range
Resolution
MR
Lux (lx)
Footcandle (fc)
Lux (lx)
Footcandle (fc)
l
0.1 ... 199.9
0.01 ... 19.99
0.1
0.01
ll
1 ... 1999
0.1 ... 199.9
1
0.1
lll
10 ... 19990
1 ... 1999
10
1
lV
100 ... 199900
10 ... 19990
100
10
MR
Candela/m2 (cd/m2)
Footlambert (fL)
cd/m2
Footlambert (fL)
l
1 ... 1999
0.1 ... 199.9
1
0.1
ll
10 ... 19990
1 ... 1999
10
1
lll
100 ... 199900
10 ... 19990
100
10
lV
1000 ... 1999000
100 ... 199900
1000
100
MAVOLUX 5032 B USB
Illuminance
Luminance
(with attachment)
38
MR
Lux (lx)
Footcandle (fc)
Lux (lx)
Footcandle (fc)
l
0.01 ... 19.99
0.001 ... 19.99
0.01
0.001
ll
0.1 ... 199.9
0.1 ... 199.9
0.1
0.01
lll
1 ... 1999
1 ... 1999
1
0.1
lV
10 ... 19990
10 ... 19990
10
1
V
100 ... 199900
100 ... 199900
100
1
MR
Candela/m2 (cd/m2)
Footlambert (fL)
cd/m2
Footlambert (fL)
l
0.1 ... 199.9
0.01 ... 19.99
0.1
0.01
ll
1 ... 1999
0.1 ... 199.9
1
0.1
lll
10 ... 19990
1 ... 1999
10
1
lV
100 ... 199900
10 ... 19990
100
10
V
1000 ... 1999000
100 ... 199900
1000
100
Type
Data Sheet No.
MAVOLUX 5032 C USB
GFLDOKU010410GB
Article Number
M502G
MAVOLUX 5032 B USB
GFLDOKU010410GB
M503G
Factory certificate (net price)
GFLDOKU010410GB
H997B
Luminance attachment
GFLDOKU010410GB
5908V0120
Calculating disc
GFLDOKU010410GB
5999V0380
Adapter disc
GFLDOKU010410GB
M499G
Made in Germany
Luminance Meters
MAVO-MONITOR USB
Precision Digital Measuring Instrument for Measuring Luminance in Candela/m²
or Footlamberts
The precision digital measuring instrument for measuring luminance is placed directly onto self-luminous
surfaces, or surfaces through which light is passed, such as monitors (CRT/LCD, background illumination), TV
screens, light tables, trough luminaires, illuminated advertising surfaces, traffic signs and viewing screens. A
handy, special measuring instrument for professional use in industrial, commercial and service applications, for
special testing and inspection in accordance with existing safety regulations, for example at workstations with
monitor screens, and in the fields of medical engineering and office technology.
• Precision measurement of luminance classified in accordance with DIN 5032-7 class B and CIE no. 69
• The silicon photodiode is color corrected, i.e. its spectral sensitivity is matched to that of the human eye V(l).
• Measurement of luminance in cd/m² or fL
• Easy operation
• 3½ place display
• Storage of up to 100 measured values
• USB 1.1 interface
• Automatic and manual measuring range selection
● Included:
Carrying case, CD ROM with software for displaying measured values, acquiring measured
values and device control, USB cable, battery and operating instructions
● Optional accessories: Adapter disc for measurements at LCD monitors for the avoidance of obliquely
incident light
● Factory certificate upon request
The traceability of measurement results to the national standard maintained by the PTB (German Federal
Institute of Physics and Metrology) is assured by means of the Wi 41G standard lamp.
The factory certificate is required for all applications for which measurements and testing in accordance
with legal directives and regulations are required.
Measured Quantity
MR
l
ll
lll
lV
Luminance
MAVO-MONITOR USB
Measuring Range
Candela/m2 (cd/m2)
Footlambert (fL)
0.01 ... 19.99
0.001 ... 1.999
0.1 ... 199.9
0.01 ... 19.99
1 ... 1999
0.1 ... 199.9
10 ... 19990
1 ... 1999
cd/m2
0.01
0.1
1
10
Type
Data Sheet No.
Article Number
MAVO-MONITOR USB
GFLDOKU010410GB
M504G
Factory certificate (net price)
GFLDOKU010410GB
H997B
Adapter disc
GFLDOKU010410GB
M499G
Resolution
Footlambert (fL)
0.001
0.01
0.1
1
Accurate lux measurements are a must for architects and lighting
designers. The MAVOLUX 5032 USB is also available with a class B
probe for this purpose.
Please send RFQs, orders and requests for additional information to
the address listed below, or visit our website.
Made in Germany
Foto- u. Lichtmesstechnik GmbH
Phone: +49 911 / 8602-170
Photometry Sales
Fax: +49 911 / 8602-142
Thomas-Mann-Str. 16 - 20
e-mail: [email protected]
90471 Nürnberg, Germany
http://www.gossen-photo.de
39
Energy and Power Disturbance Analyzer
MAVOWATT 50
3-Phase Energy and Power Disturbance Analyzer
The MAVOWATT 50 energy and power disturbance analyzer measures electrical quantities in DC
systems, as well as in single and three-phase AC systems with any load.
Broadband measurement is laid out for line frequencies of up to 1 kHz, and covers everything from
railway power at 16 2/3 Hz through mains power with 50 or 60 Hz, right on up to onboard electrical
systems with 400 Hz.
Eight isolated measuring circuits – four each for voltage and current – prevent equalizing current and
allow for simultaneous measurement of phase and neutral conductor voltage and current.
By connecting a suitable measuring transducer, the fourth channel can be used alternatively for the
measurement of other physical quantities, e.g. the temperature of a motor or transformer, or wind
speed at a wind power turbine.
Measurements at frequency converter outputs are also possible within a broad range.
The broad spectrum of possible applications ranges from acquisition, display and recording of mains
quantities to logging and analysis of energy consumption, right on up to calculation and statistical
analysis of characteristic voltage quality from power supply systems in accordance with EN50160.
In industrial applications, the precision measuring instrument is used to determine characteristic
quantities of electrical consumers and generators in steady-state, as well as during dynamic
processes. It also functions as a test instrument and compares harmonic current generated by
electrical equipment, as well as voltage fluctuation, with specified limit values.
Thanks to its compact, rugged design, the MAVOWATT 50 is not only suitable for stationary use, but
rather for mobile applications as well. The integrated rechargeable battery supplies power to the
measuring instrument for periods of up to several minutes in the event of power failure.
L
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Complete power disturbance analysis with simultaneous measurement of all relevant mains quantities
Power and energy analysis in power supply systems, as well as at the outputs of frequency converters
Harmonic analysis up to the 50th harmonic including sub-harmonics
Mains quality per EN50160 with statistical bar graph (Quick View)
Flicker analysis in accordance with EN 61000-4-15
8 isolated measuring circuits (4 voltage and 4 current), 100 kHz sampling rate per measuring circuit
Color touch-screen display, 5½", ¼ VGA
Storage of measurement data and settings to plug-in CF memory card or USB memory stick
USB interface for PC – external memory expansion
Ethernet TCP/IP with integrated web server for remote control and read-out
4 digital status inputs for indicating consumer operating states
4 digital control inputs for synchronizing the measuring interval, and as meter inputs
1 relay output for alarms
Power supply output for active current sensors
Integrated rechargeable battery with charging controller for power failures
Worldwide use is made possible with a broad range variable power pack (85 to 250 V AC-DC)
Functionally covered standards: EN 50160, EN 61000-3-2, /-3-3, /-3-12, /-4-7, /-4-15, /-4-30
● Included:
3-phase energy and power disturbance analyzer, to 1 kHz,
8 electrically isolated measuring channels, set of measurement cables, mains cable,
USB cable, network cable (crossed), convenient carrying case
● Optional accessories: Z201A, Z202A, Z203A, Z821B clip-on current-voltage transformers.
WZ11B, Z13B, Z3512A clip-on current sensors,
CF3x45, AF033A, AF33A, AF101A, AF11A flexible current sensors
See page 41 for Z860A, Z861A, Z862A, Z863A shunt resistors.
See page 48 for Z501L: USB → RS232 interface converter.
➲ Seminar: GTT1643
40
Type
Data Sheet No.
Article Number
MAVOWATT 50
3-349-342-03
M816A
DKD calibration certificate
–
–
Made in Germany
Accessories for Power Disturbance Analyzer
Current Measuring Accessories for the
MAVOWATT 50
Clip-on current-voltage transformers, current sensors, shunt resistors
Type
CF3x45
Max.
Applica- Meas.
Wire Dia. tion ➲ Cat.
CF3x45 3-phase set, C-FLEX flexible AC current 3 ea.
a, b, c
sensor, switchable, 10 Hz to 20 kHz, with 45 cm
battery and power pack
circumf.
Range Usable for
MAVOWATT 50
600 V
CAT III
Output
Signal
5 … 200 A~
5 … 2000 A~
50A~ … 20 kA~
10 mV/A
1 mV/A
0.1 mV/A
AF033A AmpFLEX flexible AC current sensor,
switchable, 10 Hz to 20 kHz, with 9 V
battery (operating hours: approx. 150)
45 cm (a), b, c 1000 V
circumf.
CAT III
0.5 … 30 A~
0,5 … 300 A~
100 mV/A
10 mV/A
AF33A
AmpFLEX flexible AC current sensor,
switchable, 10 Hz to 20 kHz, with 9 V
battery (operating hours: approx. 150)
60 cm (a), b, c 1000 V
circumf.
CAT III
0.5 … 300 A~
5 … 3000 A~
10 mV/A
1 mV/A
AF101A AmpFLEX flexible AC current sensor,
switchable, 10 Hz to 20 kHz, with 9 V
battery (operating hours: approx. 150)
120 cm (a), b, c 1000 V
circumf.
CAT III
5 … 1000 A~
50A~ … 10 kA~
1 mV/A
0.1 mV/A
AF11A
AmpFLEX flexible AC current sensor, 10 45 cm (a), b, c 1000 V
Hz to 20 kHz, with 9 V battery (operating circumf.
CAT III
hours: approx. 150)
5 … 1000 A~
1 mV/A
Z821B
Clip-on AC current sensor, 30 Hz to 5 kHz 64 mm a, b, (c) 600 V
CAT II
3 … 3000 A~
0.33 mV/A
0.001 ... 1.2 A~ 1000 mV/A
0.01 ... 120 A~ 100 mV/A
10 mV/A
0.1 ... 120 A~
1 mV/A
1 ... 1200 A~
Z3512A Clip-on AC current sensor, switchable,
10 Hz…3 kHz
52 mm a, b, c
600 V
CAT III
WZ11B Clip-on AC current sensor, switchable,
30 Hz…500 Hz
20 mm a, (c)
600 V
CAT III
0.5 … 20 A~
5 … 200 A~
100 mV/A
10 mV/A
Z13B
50 mm b, c
Active AC-DC clip-on current sensor,
switchable, DC…10 kHz, with 9 V battery
(operating hours: approx. 50)
300 V
CAT IV.
0.2 … 40 A~/60 A–
0.5… 400 A~/600 A–
10 mV/A
1 mV/A
Z201A
Active AC-DC clip-on current sensor,
19 mm b, c
DC…20 kHz, with 9 V battery (operating
hours: approx. 30)
300 V
CAT III
0.01… 20 A~/30 A–
100 mV/A
Z202A
Active AC-DC clip-on current sensor,
19 mm b, c
switchable, DC…10 kHz, with 9 V battery
(operating hours: approx. 50)
300 V
CAT III
0.1 … 20 A~/30 A–
1 … 200 A~/300 A–
10 mV/A
1 mV/A
Z203A
Active AC-DC clip-on current sensor,
31 mm b, c
switchable, DC…10 kHz, with 9 V battery
(operating hours: approx. 50)
300 V
CAT III
1 … 200 A~/300 A–
1 …1000 A~/1000 A–
1 mV/A
Z860A
Plug-in shunt
50 Ω, 0.2%, 1.5 W
–
a, b
600 V
CAT III
50 µA … 20 mA
50 mV/mA
Z861A
Plug-in shunt
1 Ω, 0.2%, 1.5 W
–
a, b
600 V
CAT III
Z862A
Plug-in shunt
0.05 Ω, 0.2%, 1.5 W
–
a, b
600 V
CAT III
0.02 … 6 A
50 mV/A
Z863A
Plug-in shunt
0.01 Ω, 0.2%, 1.5 W
–
a, b
600 V
CAT III
0.1 … 16 A
10 mV/A
AF033A ... AF11A
Z3512A
Description
Z821B
➲ a = Long-term measurement
b = Harmonic measurement
1 mA … 1.2 A 1000 mV/A
c = Frequency converter measurement
Refer to data sheet 3-349-342-03 for additional information regarding current measuring accessories.
Z13B
WZ11B
Z201A...Z203A
Z860A...Z863A
Made in Germany
Type
Data Sheet No.
CF3x45
3-349-342-03
Article Number
Z824A
AF033A
3-349-342-03
Z207A
AF33A
3-349-342-03
Z207B
AF101A
3-349-342-03
Z207C
AF11A
3-349-342-03
Z207D
Z821B
3-349-342-03
Z821B
Z3512A
3-349-342-03
Z225A
WZ11B
3-349-342-03
Z208B
Z13B
3-349-342-03
Z213B
Z201A
3-349-342-03
Z201A
Z202A
3-349-342-03
Z202A
Z203A
3-349-342-03
Z203A
Z860A
3-349-342-03
Z860A
Z861A
3-349-342-03
Z861A
Z862A
3-349-342-03
Z862A
Z863A
3-349-342-03
Z863A
41
Voltage Quality Analyzers
MAVOLOG®10L/N/S
3-Phase Mains Quality Analyzer and Test Instrument for Testing per EN 50160
in Standard Combination Housing
3-phase mains quality analyzer and test instrument for testing per EN 50160
in standard combination housing including harmonic and flicker analysis
• Monitors voltage quality and simultaneously records 3-phase alternating quantities, records 3-phase AC quantities
• Internal analysis of voltage quality for short-term, daily and long-term intervals per EN 50160 and other industrial
standards
• 640 k internal memory, memory capacity can be partitioned for various measuring and test tasks in a user-specific
fashion.
• RS 485 fieldbus with multi-drop connection for up to 32 devices, alarm output for events indication
• Dimensions: 100 x 75 x 105 mm, weight: 360 gr.
Analyzer Variants
MAVOLOG series instruments have been designed to allow for the selection of ideal configurations for all types of
applications, from power generation to consumer applications, in combination with multiple instruments or as a standalone. Even the basic model, the MAVOLOG 10L+FFT/FSA, provides for comprehensive disturbance recording and line
voltage quality analysis with integrated harmonic analysis (FFT) and flicker measurement (FSA). Equipped with an LCD and
additional current inputs, the top of the line MAVOLOG 10S+FFT/FSA is a universal measuring instrument which can be
used for recording the characteristics of almost any conceivable measured quantities in 3-phase systems, and
simultaneously acquiring power disturbances and characteristics for the analysis of voltage quality.
● See page 30 for optional accessories: Z3512, Z3514 clip-on current sensor.
● See optional software on page 44.
➲ See page 91 for training seminar: GTT1642
Features
Voltage
Measurement inputs
Dips, failures
Swells
Asymmetry
Frequency
Harmonics
Flicker (Pst, Plt)
EN 50160 analysis
Current
Measurement inputs
Characteristics for voltage dips
Harmonics
Power / Energy
Active power P1, P2, P3, PΣ
Apparent power SΣ
Reactive power QΣ
Power factor PFΣ
Active energy WPΣ
Reactive energy WQΣ
Alphanumeric LCD
Measured values, analyses
Parameters configuration
10L+FFT/FSA
MAVOLOG
10N+FFT/FSA
10S+FFT/FSA
10S
>10 ms
>10 ms
3 x UL-L / UL-N & UN-PE
>10 ms
>10 ms
>10 ms
>10 ms
>10 ms
>10 ms
●
●
●
●
●
●
●
●
1 to 40 and THD
1 to 40 and THD
1 to 40 and THD
–
●
●
●
●
●
●
–
–
–
–
–
–
3xIL & IN
Resolution: 10 ms
1-40&THD
3xIL & IN
Resolution: 10 ms
–
–
–
–
–
–
–
–
–
–
–
–
–
●
●
●
●
●
●
●
●
●
●
●
●
–
–
10, selectable
10, selectable
10, selectable
●
●
●
MAVOLOG 10 Mobile Set
The practical solution for mobile use consisting of the following components:
MAVOLOG 10S+FFT/FSA mains quality analyzer, MAVOLOG PS/C power pack with interface converter and
MAVOLOG BP battery pack, wired and installed in a stable carrying case (46 x16 x 35 cm).
Included accessories:
• Connector cables for mains power and voltage measurement inputs including alligator clips and RS 232 interface
• METRAwin 10 for MAVOLOG parameters configuring and analysis software
The case also provides space for storing optional clip-on current transformers such as 3 each Z3512 (1000/1 A).
➲ See page 91 for training seminar: GTT1642
42
Type
Data Sheet No.
Article Number
MAVOLOG 10L+FFT/FSA
3-349-028-03
M830S
MAVOLOG 10N+FFT/FSA
3-349-028-03
M830P
MAVOLOG 10S+FFT/FSA
3-349-028-03
M830R
MAVOLOG 10S
3-349-028-03
M830V
MAVOLOG 10 Mobile Set
–
M830W
Made in Germany
Voltage Quality Analyzers
MAVOLOG®PS/C
230 V~ / 24 V – Power Pack for MAVOLOG Instruments and the MAVOLOG BP,
Additionally Integrated RS 485-232 Interface Converter
The MAVOLOG PS/C module (PS = power supply / C = converter) includes a mains power pack with 24 V DC
output for supplying power to as many as five MAVOLOG 10 instruments and one MAVOLOG BP, as well as a
bidirectional RS 232-485 interface converter for communications between a PC and MAVOLOG control software.
Up to 32 MAVOLOG 10 instruments can be connected to the RS 485 bus, which can have a length of up to 1 km,
and which functions at a maximum data transmission rate of 115 kBaud.
The standard version is laid out for an input voltage of 230 V AC.
• Dimensions: 75 x 55 x 111 mm (H x W x D), weight: approx. 800 gr.
The MAVOLOG PS/C universal variant (no photo) has a broad range input for 60 to 230 V AC / DC.
• Dimensions: 75 x 100 x 111 mm (H x W x D), weight: approx. 350 gr.
.
MAVOLOG®BP
Type
Data Sheet No.
Article Number
MAVOLOG PS/C
3-349-045-03
Z863D
MAVOLOG PS/C universal
–
Z863G
Battery Pack as Emergency Backup for MAVOLOG Instruments in the Event of
Power Failure
The MAVOLOG BP (BP = battery pack) is an uninterruptible DC power supply which, in combination with the
MAVOLOG PS/C, automatically supplies power to connected MAVOLOG 10 instruments in the event of mains
power failure.
Depending upon the number and type of instruments, they can be operated with a fully charged backup battery
for up to 10 hours.
Integrated electronics regulate and monitor the charging process, assuring reliable availability of supply power
and long backup battery service life.
• Dimensions: 75 x 55 x 109 mm (H x W x D), weight: approx. 480 gr.
MAVOLOG®Dial-Up
Type
Data Sheet No.
Article Number
MAVOLOG BP
3-349-044-03
Z863E
Analog Modem for Long Distance Data Transmission in Standard Combination Housing
The MAVOLOG analog dial-up modem connects the installed MAVOLOG mains monitoring system to a master
computer via public telephone lines for remote parameters configuration, control and data queries.
An SMS message can be transmitted to a cell phone, a fax machine etc. in the event of power disturbance.
• Dimensions: 75 x 45 x 110 mm (H x W x D), weight: approx. 230 gr.
• Power supply: 10 ... 60 V−, e.g. with the MAVOLOG PS/C
Additional modems upon request, e.g. for ISDN, GSM and Ethernet
Made in Germany
Type
Data Sheet No.
Article Number
MAVOLOG Dial-Up
–
Z864C
43
Software for Voltage Quality Analyzers
METRAwin 10/MAVOLOG
Parameters Configuration and Visualization Software
METRAwin for MAVOLOG 10 software is used for configuring parameters and visualizing data from the
MAVOLOG 10. It includes the following functions:
• Configuration of device parameters (hook-up configuration, memory parameters)
• Memory mode initialization
• Read-out and printout of complete statistics, as well as daily statistics
• Read-in and graphic representation of interval data
• Read-in and representation of events data in list format, as well as graphic representation of 10 ms RMS values for
the respective event curves
• Read-in and graphic representation of harmonics
• Online visualization of selected measured quantities
• Interval data or measurement series recorded online are displayed at the monitor as a line diagram or a bar graph
with horizontal time axis and can be analyzed with two pointers.
• The data logger display shows time and measured values numerically in an easy to read table, and allows for data
export to other programs with the Windows clipboard.
• Event data read out from one or several MAVALOGs are listed in the order in which they occurred and can be printed
as an events list.
• In the event of voltage dips, failure or swells, these are displayed in a time sequence which can be measured off
with cursors. If the current signal is simultaneously available, conclusions may be drawn regarding the cause of the
disturbances.
• Complete statistics and daily maximum values provide information concerning all important factors at a single
glance.
• Parameters configuration for interconnected instruments as regards the measuring circuit, recording parameters,
memory configuration etc., is accomplished by means of a menu-driven process.
• In the online mode, up to ten selectable measured quantities can be scanned and recorded once every second.
System requirements: MS Windows 95, 98, ME, NT, 2000 or XP
PC.doc-ACCESS/MAVOLOG
Type
Data Sheet No.
Article Number
METRAwin10 / MAVOLOG
–
Z852D
Software for the Generation of Reports and Graphics
PC.doc-ACCESS for MAVOLOG 10 is a database program based on MICROSOFT OFFICE products including
WinWord, Excel and Access for the management, presentation and documentation of data recorded with the
MAVOLOG 10. The database software allows for the management of data from any number of MAVOLOG 10
instruments, and for interactive or automatic, time controlled querying with the help of a scheduler. In this way,
the software allows for comprehensive, detailed long-term analysis of mains quality within a power supply
system with numerous measuring stations.
Graphics Processing with MS Excel
• Sorting of measured values according to time of occurrence, size (ascending/descending) and frequency
distribution
• Data analysis (with minimum values/mean values/95%/maximum values) in compliance with EN 50160, and with
adjustable limit values
• Time sorted lists of recorded events from several MAVOLOG 10 instruments during an adjustable observation period
• Analysis of voltage dips relative to standard limits/classes (ITIC=CBEMA, NRS048)
• Printout of events list with explanatory remarks
• Analysis of statistical data with reference to EN 50160 and adjustable limit values
• Report printing with Go/No-Go evaluation in MS Word
• Scheduler for time controlled remote read-out from MAVOLOG 10 instruments with the help of METRAwin 10
software via RS 232 interface or modem, or via Ethernet with a slave PC as gateway
System requirements: MS Windows 95, 98, ME, NT, 2000 or XP
MS-Office Professional 97/2000
44
Type
Data Sheet No.
Article Number
PC.doc-ACCESS / MAVOLOG
–
Z852F
Made in Germany
Test Instruments – VDE 0100 / IEC 364-6-61
PROFiTEST ® 0100S-II
PROFITEST 0100S-II with Optional PSI Module
PROFITEST PSI-BC
International Test Instrument for Electrical Systems with True Two-Hand Operation
All protective safety measures required by DIN VDE 0100 part 610, as well as the corresponding international
regulations (e.g. IEC 364-6-61, HD 364-6-61.S1), can be tested with the PROFiTEST 0100SII:
• Insulation resistance measurement per DIN VDE 0413 part 2 / EN 61557-2
• Loop impedance measurement per DIN VDE 0413 part 3 / EN 61557-3
• Low-resistance measurement per DIN VDE 0413 part 4 / EN 61557-4
• RCD testing per DIN VDE 0413 part 6 / EN 61557-6 (complete test)
• Earthing resistance measurement per DIN VDE 0413 part 5 / EN 61557-5
• Phase sequence testing per DIN VDE 0413 part 7 / EN 61557-7
• Line impedance and standing surface insulation resistance
• Earth leakage resistance, voltage, frequency, biasing current, leakage current, circulating current, current to 150 A
Additional functions:
• Energy meter start-up testing, cable length determination, recommended fuse types
Special features:
• Loop impedance measurements to 550 V with display of allowable overcurrent protective devices
• Current measurements with clip-on ammeters as of 1 mA
• Low-resistance measurement with calculation of cable lengths
• Universal connector system – interchangeable plug inserts and 2-pole plug-in adapter assure worldwide compatibility
• Integrated processor-controlled charger for rechargeable NiCd and NiMH batteries
• Large voltage and frequency ranges. The range of applications includes all alternating current and 3-phase systems
from 60 to 800 V with frequencies from 15.4 to 420 Hz
• Large, easy to read display with background illumination: Menus, schematic diagrams, online help, measured,
reference and nominal values etc. appear in plain text at a dot matrix display.
• Indication of connection errors and limit value violations, meter start-up direction
• Always current with software updates via IRDA interface
• Direct measurement of leakage current with clip-on ammeter, indirect with rising test current
• Temperature and humidity measurement with the Z541A adapter as an accessory
• Clear-cut, concise operation with a single function selector switch and three keys, as well as remote control
• Online help and schematic diagrams can be queried for all basic functions and sub-functions
• Immediate printout of measured value tables via PSI plug-in module
• Data transmission to the PC via RS 232 interface and report generation with PC.doc-win, PC.base-m and PS3 software
• 6 different languages can be selected, and additional languages can be uploaded via the IRDA interface.
● Standard equipment for following versions:
• PROFi TEST 0100S-II: VDE 0100 test instrument with the following languages: German, English, French, Italian,
Spanish, Dutch, including socket, earth contact plug, 2-pole adapter, cable for expansion to 3-pole adapter,
2 alligator clips, set of batteries, operating instructions and test report, without PSI module
• PROFiTEST 0100S-UK-II: UK version with the following languages: English, Danish, Swedish, Finnish, German,
Dutch
• PROFiTEST 0100S-E-II: Iberian version with languages: Spanish, Catalan, Gallic, Basque, Portuguese, English
• PROFiTEST 0100S-O-II: Slavic version with the following languages: Czech, Slovak, Hungarian, German, Polish
● Optional accessories as of page 47, or see table on page 75.
➲ See page 91 for training seminar: GTT1210, GTT1224B, GTT1224G, GTT1226
Type
PROFi TEST 0100S-II
RCCB testing with or w/o tripping: – With nominal residual current 10, 30, 100, 300, 500 mA
Contact voltage
0 ... 70 V
Time to trip
0 ... 1000 ms
– With rising residual current
Contact voltage
0 ... 50 V
Tripping current
0.3 ... 1.3 x IΔN
Overcurrent protective devices
Loop resistance (... 550 V)
0 ... 10 Ω
Short-circuit current
0 A ... 50 kA
Earthing measurements
Earth resistance
0.15 Ω ... 10 kΩ
Earth electrode voltage
0 ... 253 V
Standing surface insulation res. 0 ... 1 MΩ
Insulation resistance measurement
Insulation resistance
0 ... 300 MΩ
Nominal voltage
100 / 250 / 500 V
Nominal Current
1 mA
Insulation and earth leakage res. 50 kΩ ... 100 MΩ
Low-value resistance
0 ... 100 Ω
Alternating Voltage
0 ... 253 / 500 / 850 V
Frequency
15 ... 420 Hz
Current measurement with clip
1 mA ... clip measuring range
Nominal ranges of use
Voltage
60 ... 500 V
Frequency
15.4 ... 420 Hz
Power supply
6 ea. 1.5 V mignon cell per IEC LR 6 (AA)
Dimensions / weight
240 x 340 x 62 mm / 2.5 kg
Made in Germany
Type
Data Sheet No.
Article Number
PROFiTEST 0100S-II
3-348-888-03
M520A
PROFiTEST 0100S-UK-II
3-348-888-03
M520B
PROFiTEST 0100S-E-II
3-348-888-03
M520C
PROFiTEST 0100S-O-II
3-348-888-03
M520D
Factory calibration certificate
−
−
45
Test Instruments – VDE 0100 / IEC 364-6-61
PROFITEST ONE
Universal Protective Measure Test Instrument per VDE 0100 for Daily Use
All types of protective measure testing for electrical systems can be executed with the PROFiTEST ONE in accordance with VDE 0100, part 610, and VDE 0413, parts 1 through 7.
Testing of residual current devices (RCCBs)
• Measurement of contact voltage without tripping the RCCB. Contact voltage is measured with reference to nominal
residual current using 1/3 of the nominal residual current value.
• Tripping test with nominal residual current, measurement of tripping time
Special tests for equipment and RCCBs
• Testing of equipment and RCCBs with rising residual current including indication of tripping current and contact
voltage at the moment the RCCB is tripped.
• Testing of RCCBs (10 and 30 mA) with 5 x IΔN
• Testing of RCCBs which are suitable for pulsating residual direct current; testing is conducted with positive or
negative half-waves.
• Testing of RCCBs with adjustable residual current for determining contact voltage and tripping current
Testing of special RCCBs
• Selective S , SRCDs, PRCDs (Schukomat, Sidos and similar), type G
• Testing of RCCBs in IT systems
Special features:
• Display of approved fuse types for electrical systems
• Energy meter start-up testing
• Calculation of cable lengths for common cross-sections for copper wire
• Measurement of biasing current, leakage current and circulating current of up to 1 A, as well as working current of
up to 150 A with the Clip 0100S clip-on current sensor as an accessory
• Phase sequence measurement (including highest line-to-line voltage)
• Temperature and humidity measurement with the Z541A adapter as an accessory
● Included:
PROFITEST ONE test instrument, 3-pole measuring adapter, neck strap, batteries, operating
instructions, WinProfi software for communications between the test instrument and the PC
● Optional accessories as of page 47, or see table on page 75.
➲ See page 91 for training seminar: GTT1210, GTT1224B, GTT1224G, GTT1226
PGS... Test Sets
Type
Data Sheet No.
Article Number
PROFITEST ONE
3-349-329-03
M520G
Factory calibration certificate
−
−
Test Sets in Carrying Case for Testing per DIN VDE 0100
In addition to the PROFiTEST 0100S-II, test sets include all essential accessories required for testing electrical
systems in accordance with DIN VDE 0100 packed in a carrying case.
Included with individual test sets:
Designation
Type
Universal carrying pouch
Carrying case
Metal case
PROFi TEST 0100S-II
PROFi TEST PSI-E
PROFi TEST PSI-BC
Digital multimeter
Software, interface cable
Adapter
Earth spike
Test probe extension
Variable plug adapter set
Plug insert
Plug insert
Measurement cable, 25 m
F2000
K2000
Z504J
M520A
M522A
M522D
METRAmax 12
WinProfi
DA-II
SP350
Telearm1
Z500A
PRO-RLO
PRO-Schuko
TR25
117T
210
PGS ...
211
215
216
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
2000
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
➲ See page 91 for training seminar: GTT1210
46
Type
Data Sheet No.
Article Number
PGS 117T
3-348-888-03
M509T
PGS 210
3-348-888-03
M509L
PGS 211
3-348-888-03
M509M
PGS 215
3-348-888-03
M509R
PGS 216
3-348-888-03
M509S
PGS 2000
3-348-888-03
M509P
Made in Germany
Test Instruments – VDE 0100 / IEC 364-6-61
PROFi TEST® PSI-E/PSI-BC/SI-BC
PSI Module for PROFi TEST 0100S-II or PROFITEST ONE
PROFiTEST PSI-E
The PSI module (printer, storage, interface) functions simultaneously as printer, memory and interface. It is
attached to the test instrument and secured with two snap-hooks. Values measured with the PROFi TEST 0100SII are transmitted to the PSI module by means of infrared light, where they are stored to memory. It offers sufficient capacity for approximately 4400 measurement values from 200 electrical circuits.
The measurement values from all of the recorded electrical circuits can be read out to the test instrument display
in tabular form, and can be printed out onto a recording chart along with date and time by simply activating a
key. The measurement value table can, for example, be attached directly to an approval report.
The PSI module is equipped with an RS 232 interface. Stored data can be transmitted via the interface to a PC
and processed with PC.doc and PC.base software independent of the test instrument at a later point in time.
Reports can be generated directly at a Centronics printer from the PSI module in A4 format with the DA-II printer
adapter (optional).
•
•
•
•
3 functions with a single device: printer, memory and interface
Report generating functions: numeric entry of buildings and electrical circuits
Reports can be printed out in A4 format at Centronics printers with the help of a printer adapter (accessory).
Power supply: 4 ea. mignon cell per IEC LR 6 (AA)
PROFiTEST PSI-BC: same as PROFiTEST PSI-E with:
• Expanded report generating functions: alphanumeric entry of buildings, distributors, RCDs, electrical circuits and
defects, or data entry with B3261 barcode scanner (see page 73)
PROFiTEST SI-BC: same as PROFiTEST PSI-BC, but without printer
● Included:
PROFiTEST DC II
PROFiTEST PSI-E or BC, 2 rolls paper chart, 1 ribbon cartridge, batteries and operating instructions
PROFiTEST SI-BC, batteries, operating instructions
Type
Data Sheet No.
PROFiTEST PSI-E
3-348-976-03
Article Number
M522A
PROFiTEST PSI-BC
3-348-976-03
M522D
PROFiTEST SI-BC
3-348-976-03
M522E
RS 232 interface cable, Z3241
–
GTZ3241000R0001A1
Add-On Device for the Measurement of Loop Resistance in TN Systems
This add-on device allows for the measurement of loop resistance in TN systems which are equipped with RCCBs
with the PROFi TEST 0100S-II.
The add-on device suppresses tripping of RCCBs.
The PROFi TEST DC II can also be used for measuring DC components, tripping current and time to trip for DC
sensitive RCCBs (selective DC versions as well).
• Accessories: Adapter with 3 test leads for PROFiTEST DC-II in systems without earthing contact sockets
• Dimensions: 205 x 120 x 100 mm (H x W x D), weight: 1.5 kg without connector cable
Z541A
Type
Data Sheet No.
Article Number
PROFi TEST DC II
3-348-974-03
M523A
3-pole adapter for DC-II
3-348-974-03
Z523A
Adapter for Temperature and Atmospheric Humidity Measurement
Adapter for temperature and atmospheric humidity measurement with infrared interface to the measuring
instrument.
For determining ambient temperature and atmospheric humidity during floor measurements including:
• Leakage, insulation and surface resistance
• Temperature range: -10 to +50° C
• Relative humidity measuring range: 10 to 90%
Type
T/H sensor
Made in Germany
Data Sheet No.
Article Number
Z541A
47
Testers – DIN VDE 0100 / IEC 364-6-61: Add-Ons
IrDa-USB Converter
IR Interface Adapter for Connecting a Test Instrument to a PC: IrDa-USB
IrDa-USB converter:
Electrically isolated infrared interface for data transmission between test instrument and a PC (USB).
Data transfer to and from the IrDa interfaces of our PROFiTEST 0100S-II, PROFiTEST C, METRISO C and GEOHM C test
instruments with modern PCs which are equipped with USB ports only.
● The cable is furnished with a CD ROM including the required device drivers for Windows 98SE, ME, 2000
and XP.
RS 232 – USB Converter
Type
Data Sheet No.
Article Number
IrDa-USB converter
–
Z501J
Adapter Cable for Connecting the RS 232 Interface to the USB Port at a PC
The interface converter is used to connect any desired device with RS 232 interface to PCs which are equipped
with USB ports only.
● The cable is also furnished with a CD ROM including the required device drivers.
CEE-CHECK 32/400
Type
Data Sheet No.
Article Number
RS 232 – USB converter
–
Z501L
Test Instrument for Power Installations with 230/400 V, 50 to 60 Hz
Power installations can be tested quickly and efficiently for correct function and electrical safety with the test
instrument. The instrument is suitable for power circuits with type CEE 32A 6h 3-phase outlets carrying a voltage
of 230/400 V, 50 to 60 Hz.
If the power installation to which the power circuit belongs is equipped with a residual current protective device,
it must also be tested for correct functioning with a test instrument in accordance with EN 61 557-6 /
IEC 61 557-6.
A warm-up period of at least 5 minutes must be observed after connecting the instrument at ambient
temperatures of less than -10° C.
• Phase and phase sequence testing
• Neutral conductor testing
• Detection of reversal of neutral and protective conductors
• Testing the protective conductor for absence of voltage
• Earthing resistance test
• Dimensions (L x W x H): 160 x 80 x 65 mm, weight approx. 750 gr.
48
● Included:
CEE-CHECK 32/400 test instrument in HC20 case, operating instructions
.
Type
Data Sheet No.
Article Number
CEE-CHECK 32/400
3-349-124-03
M662C
Made in Germany
Testers – DIN VDE 0100 / IEC 364-6-61: Accessories
Test Instrument Accessories –
DIN VDE 0100 / IEC 364-6-61
PRO-Schuko
-CH
-GB
Adapters, Plug Inserts, Power Packs, Clip-On Current Sensors, Cables, Carrying Pouches,
Cases etc.
3-pole adapter for DC-II:
Adapter for PROFi TEST DC-II in systems without earthing contact sockets
PRO-A3:
Measuring adapter for systems, 3-phase current, phase sequence with the
PROFi TEST 0100S-II (included with the PROFiTEST 0100S-II)
PRO-Schuko:
Plug insert for PROFiTEST 0100S-II in Germany and other countries with
appropriate plug systems
PRO-CH:
Plug insert for PROFiTEST 0100S-II in Switzerland per SEV
PRO-GB:
Plug insert for PROFiTEST 0100S-II in Great Britain per British Standard
PRO-RSA:
Plug insert for PROFiTEST 0100S-II in South Africa
PRO-UNI:
Plug insert with 3 connector cables for any connection standards
PRO-RLO:
Plug insert with 10 m cable for PE measurements and the like
Battery set 0100S:
6 special rechargeable NiMH batteries in a battery holder (1300 mAh)
NA 0100S:
Charger for battery set 0100S
Clip 0100S:
Clip-on current sensor for measuring fault current with 3.5 mm jack plug
Z3512A:
Clip-on current sensor, selectable measuring range: 0 ... 1/100/1000A~ AV~ ±
(0.7% ... 0.2%)
Clip-on adapter cable:
Cable for connecting clip-on ammeters with banana plugs to the jack socket at
the PROFiTEST 0100S-II
F2000:
Universal carrying pouch for PROFiTEST 0100S-II, PROFiTEST 204,
METRISO 5000A/AK and SECUTEST ...
K2000:
Aluminum case for PROFiTEST 0100S-II and accessories
Z504J:
Metal case
-RSA
PRO-RLO
PRO-UNI
Clip 0100S
Z3512A
Z504J
.
F2000
K2000
Made in Germany
Type
Data Sheet No.
3-pole adapter for DC-II
–
Article Number
Z523A
PRO-A3
–
GTZ3214000R0001
PRO-Schuko
–
GTZ3228000R0001
PRO-CH
–
GTZ3225000R0001
GTZ3226000R0001
PRO-GB
–
PRO-RSA
–
Z501A
PRO-UNI
–
GTZ3214000R0003
GTZ3214000R0002
PRO-RLO
–
Battery set 0100S
–
Z501B
NA 0100S
–
Z501D
Clip 0100S
–
Z501E
Z3512A
–
Z225A
Clip-on adapter cable
–
Z501G
F2000
–
Z700D
K2000
–
Z504K
Z504J
–
Z504J
49
Test Instruments – VDE 0100 / IEC 364-6-61
PROFi TEST C
Test Instruments – DIN VDE 0100 / IEC 364-6-61
Protective measures test instrument for loop resistance measurement, calculation of short-circuit current and
display of suitable fuse ratings. In addition to complete testing for the effectiveness of RCCBs, the instrument is
also capable of phase sequence analysis, as well as the measurement of voltage and frequency.
• The extremely rugged 2-component housing with integral impact guard makes this instrument perfect for use by on-site
installation teams, and it supplements the PROFITEST 204 in accordance with the new EN 60204 in an ideal fashion.
• A large, illuminated, anti-glare graphic display allows for clear, intuitive, menu-driven operation.
• Operation is quick and easy with a total of only 5 keys.
• The integrated measured value memory can be read out via the infrared data interface, which is included as
standard equipment.
• Printouts and reports can also be read out via the IR interface, and it can be used for updates to assure that the
instrument is always current.
• Stored measured values can be accurately assigned to their respective electrical circuits, distributors and buildings
with the alphanumeric keypad.
• Unambiguous Go/No-Go decisions are made possible with LEDs and display messages.
• The desired language can be selected.
• A phase tester is integrated into the instrument.
• A carrying strap, a stand, holders for test probes and cables and a recharging socket for NiCd/NiMH batteries round
out the convenient and safe PROFITEST C.
• Dimensions: 275 x 140 x 65 mm (H x W x D), weight: 1.2 kg with batteries
• Power supply: 4 ea. mignon cell per IEC LR 14
● Software:
• PS3: software for test instruments including systems and equipment management, and reports generating (see page 77)
• PC.doc-WORD / PC.doc-ACCESS: documentation and management software for measurements per DIN VDE 0701/
0702 and 0100 (see page 76)
WinProfi: for communications between the test instrument and the PC (included)
● Included:
M521A: PROFITEST C test instrument, operating instructions, factory calibration certificate
M521B: Same as M521A with plug for Switzerland (SEV)
M508A: Set consisting of PROFiTEST C, METRISO C, 3-pole adapter, IrDa 0100 adapter cable,
KS17 measurement cables, in HC 40 hard case
M508B: Same as M508A with plug for Switzerland (SEV)
● Optional extras:
PROFITEST DC-II, IrDa 0100S, IrDa-USB converter, see page 48
● Optional accessories:
NA 0100S charger, see page 49 or table on page 75
HC30-C and HC40: hard case with blister inserts for 1 or 2 series C test instrument with accessories
Z521A: 3-phase measuring adapter with earth contact plug, Z521B: 3-phase measuring adapter with Swiss
plug, Z521C: 3-phase measuring adapter with UK plug
➲ See page 91 for training seminar: GTT1210, GTT1224B, GTT1224G, GTT1226
Function
Measured Quantity
Measuring Range
(display range IK)
U L–PE (N)
U N–PE
U L–PE /U N–PE /U L–N
f
U3~
U3∼
IΔ
Z Loop
RE
50
Intrinsic Error
Nominal Range
of Use
0 ... 300 V / (0 ... 600 V)
± (2% rdg. + 2 d)
108 ... 253 V
15.0 ... 650 Hz
± (0.1% rdg. + 1 d)
15 ... 70 Hz
0 ... 500 V / (0 ... 600 V)
± (2% rdg. + 2 d)
108 ... 440 V
U IΔN
0 ... 99.9 V
± (12.5% rdg. + 2 d) + (2.5% rdg. - 2 d)
5 ... 70 V
R E / I ΔN = 10 mA
10 Ω ... 9.99 kΩ
–
Calculated value
...
...
R E / I ΔN = 500 mA
0.2 Ω ... 380 Ω
I Δ / I ΔN = 10 mA
3.0 mA ... 13.0 mA
...
...
I Δ / I ΔN = 500 mA
150 mA ... 650 mA
U IΔ / U L = 25 mA
0 V ... 25.0 V
U IΔ / U L = 50 mA
± (5% rdg. + 2 d)
3.0 mA ... 13.0 mA
150 mA ... 650 mA
0 ... 25.0 V
0 V ... 50.0 V
+ (12.5% rdg. + 2 d)
+ (2.5% rdg. – 2 d)
0 V ... 50.0 V
t A (I ΔN / 5 · I ΔN)
0 ms ... 999 ms
± 3 ms
0 ms ... 1000 ms
Z Loop
0.01 Ω ... 30.0 Ω
0 Ω ... 9.99 Ω
± 5 D ± (6% rdg. + 3 d)
0.25 Ω ... 9.99 Ω
10.0 Ω ... 9.99 kΩ
± (4% rdg. + 3 d)
10.0 Ω ... 9.99 kΩ
RE
Type
Data Sheet No.
Article Number
PROFiTEST C
3-349-075-03
M521A
PROFiTEST C-CH
3-349-075-03
M521B
Set PROFiTEST C / METRISO C
3-349-075-03/-086-03
M508A
Set PROFiTEST C / METRISO C-CH
3-349-075-03/-086-03
M508B
3-pole adapter
–
Z521A
3-pole adapter / CH
–
Z521B
3-pole adapter / UK
–
Z521C
HC30-C
–
Z541C
HC40
–
Z541D
0.25 Ω ... 30 Ω
Made in Germany
Testers – EN 60204/DIN VDE 0113
PROFITEST 204 / 204L
Device for Testing in Accordance with VDE 0113 / EN 60204 Including RS 232 Interface
and CENTRONICS Socket Connector for External Printer
The PROFITEST 204 is used for rapid, safe testing of electrical and electronic equipment and systems at
machinery in accordance with DIN EN 60204-1 and VDE 0113 with nominal voltages to 1000 V.
According to the regulations, the following initial and periodic tests must be performed:
• Testing for continuous electrical bonding of the protective conductor system with a 10 A test current
• Insulation resistance testing, voltage tests (HP or HV option) and testing for residual voltage
• Further tests/measurements: leakage current testing, as well as voltage and frequency measurements
• All of the values required for approval reports can be measured with this instrument.
Instrument Features:
• Clear-cut operating menus, illuminated display, two 4 m measurement cables (4-wire connection)
• Remote operation for easy use and limit value settings
• Convenient memory and report functions, data interfaces for PC and printer
• Can be expanded for rapid, on-site alphanumeric data entry and report printing
• Can be upgraded for high-voltage tests
Display: LCD dot matrix at which menus, setting options, measurement results and instructions are displayed.
Help key: Information regarding the currently selected menu item can be queried with this key.
Function selector switch: Test, report and data management functions are selected with the rotary switch.
Limit values: Limit values can be specified for each measurement.
Memory: Depending upon the number of systems stored to memory (max. 254), up to 2800 measurements can be saved.
Remote operation: The test probe with integrated control panel allows for remote triggering of protective conductor and
insulation resistance measurements, as well as storage of respective measured values. Integrated lamps indicate progress
of the currently running measurement. All PROFITEST 204 control functions can also be activated via the RS 232 interface.
Signal and display values can be read out as well.
RS 232 interface for PC and printer: This port allows for power supply and data transmission to the optionally available
SECUTEST PSI printer. Other devices can also be connected to this port with the help of an interface cable, e.g. a PC.
Centronics parallel port: for connecting commercially available printers (except for postscript printers).
Reporting facilities: The following options are available:
• Print out measurement data with the attachable SECUTEST PSI printer (accessory)
• Upload report form templates to the test instrument with the help of a PC and the included PROTOCOL program
• Select one of three report form templates included in the test instrument
• Print out measurement data with a commercially available printer with Centronics parallel port
• Transmit measurement data to a PC and process with PC.base or Excel
• PROFITEST 204, dimensions (W x D x H): 255 x 133 x 240 mm, weight: approx. 5.1 kg
● Software:
• Remote: control software for series testing at a PC
• PS3: modular universal software (see page 77)
• WinProfi: for transmitting the desired language from a PC to the test instrument (included)
● Included:
PROFITEST 204: Basic instrument with 2 test probes permanently connected by means of 4 meter long
measurement cables, 1 plug-on cable lug, mains cable with earthing contact plug,
floppy disk (D, GB, I, E, NL, DK, CZ) with download program for report templates,
test report, operating instructions
PROFITEST 204L: Test instrument same as PROFi TEST 204 with permanently connected 12 m long
measurement cable, with Start/Store function activation in the test plug
● Optional extras:
PROFITEST 204HP-2.5 kV, ...204HP-5.4 kV, SECUTEST PSI (see page 52)
● See optional accessories on page 53.
➲ See page 91 for training seminar: GTT1215, GTT1224C
Technical Data
Measured
Quantity
Protective
conductor resistance RSL
ΔU
Insulation
Resistance
RISO
Measuring
Range
0 ... 85 mΩ
85...999 mΩ
1 ... 9.99 Ω
10...25 Ω
0 ... 9.99 V
10 ... 12 V
0 ... 999 kΩ
1...9.99 MΩ
10...99.9 MΩ
100...499 MΩ
500...999 MΩ
1 ... 3 GΩ
Leak. cur. ΔI
0 ... 9.99 mA
0 ... 99.9 V
Voltage
100 ... 999 V
U DC/AC
1 ... 1.2 kV
8 ... 99.9 Hz
Frequency f~
100 ... 999 Hz
Made in Germany
Nominal
Range
of Use
10 ...
330 mΩ
Resolution
Nominal
voltage UN
Open- Nom. ShortCircuit
Cur- Circuit Measuring Error Intrinsic Error
Voltage U0 rent IN Current IK
100 µΩ
1 mΩ
–
12 V ~
10 mΩ
–
100 μW
0.01 V
–
–
12 V ~
0.1 V
1 kΩ
100/250/
0.050 ...
10 kΩ
500/1000 V
50 MΩ
100 kΩ
Max.
250 V
1.3 x UN
1 ΜW 500 / 1000
–
V
10 MΩ 1000 V
0.2...9.9 mA 0.01 mA
–
–
0.1 V
1 ... 1000 V
–
–
1V
0.01 kV
0.1 Hz
10 ...
–
–
1000 Hz
1 Hz
10 A
12 A
–
–
10 A
–
12 A
–
±(8.6%rdg. +6
d)
–
±(3% rdg. + 5d)
±(3% rdg. +10 d)
±(2% rdg. +3 d)
±(10% rdg. +3 d)
±(5.5% rdg. + 4
d) of
±(3% rdg. +2 d)
0.05 ... 50 MΩ
Max.
±(8% rdg. +2 d)
1 mA
1.6 mA
±(5% rdg. +2 d)
–
±(10% rdg. +2 d)
±(20% rdg. +2 d)
–
–
±(8.6% rdg. + 9 d) ±(5% rdg. + 5d)
–
–
±(8.6% rdg. + 9 d) ±(5% rdg. + 5d)
–
±(8.6% rdg. + 2 d) ±(2% rdg. + 1 d)
Type
Data Sheet No.
Article Number
PROFITEST 204
3-348-802-03
GTM5027000R0001
PROFITEST 204L
3-348-802-03
M505C
Factory calibration certificate
–
–
51
Testers – EN 60204/DIN VDE 0113
MetraMachine 204/2.5
MetraMachine 439/5.4
MetraMachine 204/2.5: Test System for Testing per VDE 0113, EN 60204-1
MetraMachine 439/5.4: Test System for Testing per VDE 0660, EN 60439-1
MetraMachine 204/2.5
Portable test system for all tests in accordance with EN 60204-1 (VDE 0113) and similar regulations (e.g.
VDE 0701, 0700 etc.) for machines and their electrical systems. PC communication, measured value storage and
reports.
MetraMachine 439/5:
Portable test system for testing low-voltage switchgear combinations per VDE 0660 T. 500, EN 60439-1.
● Included:
M504D (MetraMachine 204/2.5): PROFITEST 204, PROFITEST 204HP, Signal 204, Leadex 204, Caddy 204,
test report
M504E (MetraMachine 204/2.5I): PROFi TEST 204, PROFi TEST 204HP, Caddy 204, test report
M504F (MetraMachine 439/5.4): PROFi TEST 204, PROFi TEST 204HV, Signal 204, Leadex 204, Caddy 204,
test report
➲ See page 91 for training seminar: GTT1215, GTT1224C
PROFITEST 204HP-2.5 kV
PROFITEST 204HV-5.4 kV
Type
Data Sheet No.
Article Number
MetraMachine 204/2.5
3-348-802-03
M504D
MetraMachine 204-I/2.5
3-348-802-03
M504E
MetraMachine 439/5.4
3-348-802-03
M504F
Factory calibration certificate
–
–
High-Voltage Module for PROFITEST 204
Add-on features: PROFITEST 204HP-2.5 kV and 204HV-5.4 kV
• Test voltage can be selected in 50 V steps
• Rise time (ramp) adjustable from 0.1 to 99 s, test duration adjustable from 1 to 120 s
• Floating test voltage outputs, electronically controlled test sequence, test sequence can be started with test pistol
• Display of breakdown voltage and phase angle, pulse control operation, measured values can be saved to memory
• Acoustic and visual error indication
• Protection against unauthorized start-up with key switch, connector terminals for external signal lamps
Add-on features: PROFITEST 204HP
• Voltage testing in accordance with EN 60204 / VDE 0113, test power: 500 VA (short-term)
• Breaking current can be selected in 1 mA steps
Add-on features: PROFITEST 204HV
• Test power: 50 VA
• Breaking current can be selected in 0.5 mA steps
High-voltage modules which can be mounted to the base of the instrument allow for high-voltage testing.
Voltage, current and phase angle are measured with permanently attached measurement cables.
A bidirectional infrared interface at the base of the PROFITEST 204 controls the high-voltage module and transmits
measured values to the basic instrument.
• Dimensions: 254 x 130 x 285 mm, fully mounted to the caddy: 380 x 250 x 650 mm, weight: approx. 8 kg
SECUTEST PSI
Type
Data Sheet No.
Article Number
PROFi TEST 204HP-2.5kV
3-348-802-03
M505A
PROFi TEST 204HV-5.4kV
3-348-802-03
M505B
Integratable Printer/Memory Module for SECUTEST..., PROFITEST 204,
METRISO 5000D-PI and MAVOWATT 45 for Rapid On-Site Report Generation
Test results are transmitted via ribbon cable to the PSI module, which can be integrated into the instrument’s lid,
and are automatically saved to memory. All measured values for 200 to 1000 test reports can be stored to this
memory. Test results can be printed out on-site in the form of concise, documented reports which can be
furnished with date, time and text entered at the keypad.
• Dimensions: 240 x 81 x 40 mm (without knurled screws and ribbon cables), weight: approx. 0.8 kg
• Batteries: 4 ea. 1.5 V IEC LR 6 (AA mignon) if operated with batteries
Consumable materials: PS-10P = pack of 10 six meter recording charts, Z3210 = pack of 10 printer ribbon cartridges
.
52
Type
Data Sheet No.
Article Number
SECUTEST PSI
3-348-785-03
GTM5016000R0001
PS-10P
3-348-785-03
GTZ3229000R001
Z3210
3-348-785-03
GTZ3210000R001
Made in Germany
Testers – EN 60204/DIN VDE 0113
Accessories for PROFITEST 204
Signal 204, Cable Lug 204, Leadex 204, Caddy 204, Stop 204, Claim 204, PROFI-MFII,
RS 232-USB Converter, F2000
Signal 204
• Combination signal lamp on a magnetic base plate for high-voltage tests in accordance with DIN VDE 0104
Cable Lug 204 (no photo)
• Plug-on cable lug for secure attachment of the test probe to terminals
• Adapter for PE and insulation tests with the PROFiTEST 0100S-II and the PROFiTEST 204
Signal 204
Leadex 204 (no photo)
• 12 m extension for cable with test probe to which the measuring circuit fuse is installed
F2000
Caddy 204
• Trolley for basic instrument combined with high-voltage module, includes cover with side pockets
Stop 204 (no photo)
• Emergency stop switch for MetraMachine 204
Caddy 204
Claim 204
• Set of various items used to warn unauthorized persons and for securing large areas, machines or machine
components during the performance of high-voltage testing
PROFI-MFII
• Interface adapter for PC keyboards
RS 232-USB converter
• Interface adapter cable for connecting the RS 232 interface at the PROFITEST 204 test instrument to the USB port of
a PC for transferring data between the PC and the test instrument, e.g. for software updates at the test instrument
F2000
• Universal carrying pouch for PROFiTEST 0100S-II, PROFiTEST 204, METRISO 5000A/AK and SECUTEST...
Claim 204
RS 232 – USB
.
PROFI-MFII
Remote 204
Type
Data Sheet No.
Article Number
Signal 204
3-348-802-03
Z504D
Cable Lug 204
3-348-802-03
Z504E
Leadex 204
3-348-802-03
Z504C
Caddy 204
3-348-802-03
Z504A
STOP 204
3-348-802-03
Z504F
Claim 204
3-348-802-03
Z504G
Z504H
PROFI-MFII
3-348-802-03
RS 232-USB converter
3-348-802-03
Z501L
F2000
3-348-802-03
Z700D
PROFITEST 204 Control Software
Programming software in 3 languages for controlling the PROFiTEST/MACH 204 from a PC (replacement for
PROFI-SPS 204)
.
Made in Germany
Type
Data Sheet No.
Article Number
Remote 204
3-348-802-03
Z532A
53
Testers – DIN VDE 0701/0702
MINITEST⏐BASE, ...⏐Pro
MINITEST BASE: Test Instrument for DIN VDE 0702
MINITEST PRO: Test Instrument for DIN VDE 0701/0702
The test instrument is intended for testing and measuring repaired or modified devices.
MINITEST Base
Testing electrical safety of electrical equipment
per DIN VDE 0701-1: 2000 and DIN VDE 0702: 2004 with the following measurements:
• Protective conductor resistance
• Insulation resistance
• Protective conductor current – differential current method
• Contact current – direct measurement method
per DIN VDE 0701, part 240, by testing for:
• Absence of voltage by means of current measurement
• Indication of limit value violations by means of color LEDs
• The probe cable is protected by means of a fuse link.
MINITEST Pro
Additional features included with the MINITEST Pro:
• All measured values are also clearly read out at a large, digital display.
• USB interface for data logging
• MINITEST software on CD ROM
• Extensive safety features
• An RCCB is integrated into the plug on the mains cable.
● Included:
Test instrument, probe cable, operating instructions
Additional features included with the MINITEST Pro:
USB connector cable, CD ROM with “MINITEST” software
● Optional accessories:
MINITEST Software
Brush probe − Z745G − see page 61
SECU-cal 10 calibration adapter − Z715A − see page 60
Case − Z740B
➲ See page 91 for training seminar: GTT1212, GTT1216
Z740B Case
METRATESTER ® 5
Type
Data Sheet No.
MINITEST Base
3-349-357-03
Article Number
M712C
MINITEST Pro
3-349-357-03
M712D
Factory calibration cert. for basic device
−
−
Case for MINITEST
3-349-357-03
Z740B
SECU-cal 10 calibration adapter
3-349-357-03
Z715A
Brush probe
3-349-357-03
Z745G
Instruments for Electrical Safety Testing of Electrical Equipment in Accordance with
DIN VDE 0701 and DIN VDE 0702
Instrument for electrical safety testing of electrical equipment per DIN VDE 0701 and 0702
• Large digital LCD, mains connection testing with finger contact and indicator lamp
• Differential current measurement: Measurement of differential current complies with DIN VDE 0701 and 0702.
• New: 0702:2004 binding as of 1 January 2005
• Display functions: All measured values are clearly displayed at a large, digital display.
Exceeded limit values are also indicated optically, and in some cases acoustically as well.
• Dimensions (W x H x D): 190 x 140 x 95 mm, weight: approx. 1.3 kg
• Panel mount variant: METRATESTER 5-F-E
● Included: test instrument, operating instructions
● See optional accessories on page 75.
➲ See page 91 for training seminar: GTT1212, GTT1216
Technical Data:
Test
Protective conductor resistance
Insulation resistance
Equivalent leakage current
Absence of Voltage
54
Measuring Range
0 ... 19.99 Ω
0 ... 19.99 MΩ
0 ... 19.99 mA ~
0 ... 1.999 mA ~
Test
Differential current
Line voltage
Load current
Type
Data Sheet No.
Article Number
METRATESTER 5
3-348-817-03
M700D
METRATESTER 5-F-E
3-348-817-03
M700T
Measuring Range
0.01 ... 19.99 mA~
207 V ... 253 V ~
0 ... 16.00 A ~
Made in Germany
Testers – DIN VDE 0701/0702
METRATESTER®5-3P
Test Case for Testing Devices in Accordance with DIN VDE 0701 and 0702,
can also be used as a workshop test panel per DIN VDE 0104
For testing the electrical safety of single and 3-phase electrical equipment
The METRATESTER 5-3P performs the following tests in accordance with the regulations:
• Protective conductor resistance − insulation resistance
• Equivalent leakage current − differential current − contact current − protective conductor current
The METRATESTER 5-3P test case complies with guidelines for equipment required for electrical installation
operations issued by the Federal Committee for Electrical Installations, ZVEH, WFE and the electrical power utilities.
• Mains connection: The test case can either be connected to an earthing contact outlet with the two included power
cables, or to a 16 A CEE mains outlet.
• Test types: DIN VDE tests without mains operation: protective conductor resistance, insulation resistance,
equivalent leakage current.
DIN VDE tests with mains operation at all single and 3-phase devices: differential current, contact current. Function
tests with measurement of current consumption and voltage in phases L1, L2 and L3.
Protective conductor measurement is performed correctly in accordance with DIN VDE 0104.
• Contact surface for finger contact: Protective conductor potential can be tested by means of a contact surface for
finger contact. The PE signal lamp lights up if a potential difference of more than 100 V is detected between the
contact surface and the protective contact at the mains plug.
• Differential current measurement: The measurement of differential current complies with regulations for periodic
testing in accordance with DIN VDE 0702.
• Convenient testing: All safety and function tests are executed in a practical fashion by switching mains voltage or
the individual phases to the device under test with selector switches.
• Display functions: All measured values are clearly displayed at a large, digital display.
Exceeded limit values are also indicated optically, and in some cases acoustically as well.
• Rugged case design: The test case consists of an aluminum frame with a lockable lid which can be removed.
Ample space is provided for the included connection adapters and operating instructions.
• Dimensions: approx. 380 x 300 x 220 mm (with lid), weight: approx. 8 kg
● Included:
Test case with METRATESTER 5-F-E test instrument, mains cables (1 ea. with earthing contact plug)
and connector socket (1 ea. with 5-pole CEE16 A plug and coupling socket) and operating instructions
● Optional accessories:
Z600B: VL2 test adapter
The test adapter expands the functions of the METRATESTER 5-3P and SECUTEST 21F test panels.
Portable operation is possible. After connection to one of the test panels, the test adapter allows for the testing of electrical
devices and extension cables by trained electricians after repair or modification in accordance with DIN VDE 0701, as well
as for periodic testing per DIN VDE 0702.
Also allows for: Function testing for conductor continuity, short-circuit, reversed polarity (clockwise rotation)
• Connection via CEE plug, 3-pole + N + PE
• Nominal line voltage: 230 / 400 V
• Dimensions: 330 x 230 x 130 mm, weight: approx. 1.7 kg
Z745G: brush probe
• Probe for measuring protective conductor resistance, e.g. at rotating devices under test
Z745A: CEE adapter
The Z745A CEE adapter allows for quick and efficient testing of devices equipped with a CEE plug in accordance with
VDE 0701/0702.
• CEE attachment outlets: 16 A/3-pole, 16 A/5-pole, 32 A/5-pole
• Safety outlets for 3-phase devices without permanently attached plug
• Protective conductor continuity test and insulation test for each phase, and combined phases, with rotary switch
GTY3624065P01: KS13 cable set
Cable set for connecting test instruments such as the METRATESTER 5 and the SECUTEST SII (with feature F01) to the
mains without using a an earthing contact outlet, and for connecting DUTs. Consists of coupling socket with 3 permanently
connected cables, 3 measurement cables, 3 plug-on pick-up clips and 2 plug-on test probes.
Made in Germany
Type
Data Sheet No.
Article Number
METRATESTER 5-3P
–
M700S
VL2 test adapter
–
Z600B
Z745G brush probe
–
Z745G
Z745A CEE adapter
–
Z745A
KS13 cable set
–
GTY3624065P01
55
Testers – DIN VDE 0701/0702/0751
SECUTEST ®SII
Test Instrument for BGV A3 and MPG
Universal test instrument for testing the electrical safety of portable electrical equipment in commercial and
medical applications. In order to evaluate electrical safety, tests are performed for protective conductor
connections, insulation resistance and leakage current (differential current, equivalent leakage current, device
leakage current, patient leakage current, contact current).
Technical safety tests for, amongst others:
• Electrical equipment per DIN VDE 0701 part 1, 2000-9 edition, part 200
• Data processing and IT devices and equipment per DIN VDE 0701, part 240
• Periodic testing per DIN VDE 0702 (BGV A3) – new 0702:2004 valid as of 1 June 2004
• Electrical medical devices per DIN VDE 0751
Expanded functionality
• Automatic recognition of safety class (I, II) and mains connection errors
• Menu-driven test sequences: fully automated or manual
• Patient leakage current: AC and DC components measured separately
• Equivalent leakage current measurement with 230 V test voltage
• Convenient memory and report generating functions (optional)
• Data interface for PC, printer and barcodes
• Safety for the user thanks to integrated personal protection − suitable for persons with basic electro-technical instruction
• DKD calibration certificate (optional)
• Dimensions: 292 x 130 x 243 mm, weight: 4.5 kg
● Included:
SECUTEST SII – standard models (available from stock) including:
M7030-V001: SECUTEST S II standard model, M7030 with all 00 basic features (B00 through KE00) and
additional test sockets (feature F01), 200 mA test current for protective conductor resistance
M7030-V002: SECUTEST S II standard model, M7030 with all 00 basic features (B00 through KE00)
and D07 (test sequence for hospital beds)
M7030-V003: SECUTEST S II standard model, M7030 with all 00 basic features (B00 through KE00)
and E01 (SECUTEST PSI)
M7030-V005: SECUTEST S II standard model, M7030 with all 00 basic features (B00 through KE00)
and E01 (SECUTEST PSI) plus F01 (additional test sockets)
● Included:
SECUTEST SII basic device, M7030: all 00 features
Specify the designation of the basic M7030 instrument in your order,
as well as any features which deviate from feature 0!
● See optional accessories on page 75.
➲ See page 91 for training seminar:
GTT1211, GTT1212, GTT1213, GTT1214, GTT1216, GTT1224A, GTT1224D, GTT1224F, GTT1226
Type
Data Sheet No.
Article Number
M7030-V001
3-349-229-03
M7030-V001
M7030-V002
3-349-229-03
M7030-V002
M7030-V003
3-349-229-03
M7030-V003
M7030-V005
3-349-229-03
M7030-V005
SECUTEST SII basic instrument, 00 features
3-349-229-03
M7030
Connector plug, France
3-349-229-03
M7030B03
M7030B09
SECUTEST SII with Optional PSI Module
SECUTEST PSI
Connector plug, Switzerland
3-349-229-03
Adapter set for international use
3-349-229-03
M7030B11
Online instructions in English
3-349-229-03
M7030C01
Test sequence for hospital beds
3-349-229-03
M7030D07
Test sequence per customer requirement
3-349-229-03
M7030DXX
With SECUTEST PSI printer module
3-349-229-03
M7030E01
With additional test sockets
3-349-229-03
M7030F01
Integrated database for up to 99
device-specific test sequences/reports
3-349-229-03
M7030KB01
Software for acoustic indication
including special 5 m cable
3-349-229-03
M7030KD01
Direct printing after every measurement
with automated test sequence
3-349-229-03
M7030KE01
DKD calibration certificate
3-349-229-03
M7030L01
VDE Tests
Test
Prot. Conductor Res.
Measuring range
0 ... 31 Ω
Insulation Resistance
Eq. Leakage Current
Absence of Voltage
Load Current
Differential Current
0 ... 310 MΩ
0 ... 120 mA
0 ... 3.5 mA
0 ... 16 A
0 ... 31 mA
±(2.5% rdg. + 5 d)
Intrinsic error
±(5% rdg. + 5 d)
General Service Measurements
(line) Voltage
Current
Temperature
Resistance
Active Power
Apparent Power
Power Factor
0 ... 253 V
0 ... 10 A / 120 A
with clip-on ammeter
– 200 ... + 850° C
with Pt100 sensor
0 ... 150.0 kΩ
0 ... 3700 W
0 ... 4000 VA
0 ... 1.00
±(2.5% rdg. + 5 d)
±(3% rdg. + 10 d)
±(2% rdg. + 1° C)
±(1% rdg. + 3 d)
±(5% rdg. + 10 d)
56
Made in Germany
Testers –
DIN VDE 0701/0702/0751
IEC EN 60601/60335/60950/61010
SECUTEST ®SIII
optional
Test Instrument per BGV A3 (previously VBG 4), MPG Medical Device Legislation, and for
Routine Tests and Type Testing
Universal test instrument for testing the electrical safety of portable electrical equipment in commercial and
medical applications after initial manufacture or repair, and for periodic testing
Technical safety measurements for, amongst others:
• Electrical equipment per DIN VDE 0701 part 1, 2000-9 edition, part 200, part 260 1990 edition
• Data processing devices and equipment per DIN VDE 0701, part 240, and DIN EN 60950
• Periodic testing per DIN VDE 0702 (BGV A3), new 0702:2004 valid as of 1 June 2004
• Electrical medical devices per DIN VDE 0751 and EN 60601 (supplement)
• Electrical equipment for measurement, control and laboratory use per EN 61010
• Electrical household appliances per EN 60335
Expanded functionality thanks to:
• Function test with power analysis
• Temperature measurement
• Current measurement (with optional clip-on ammeter)
• Voltage and resistance measurement
• Report generation with printer module (PSI module), DA-II printer adapter or PC software
• Complete measuring system with automated measuring sequences
• User interface in various languages: English, French, German, Italian, Spanish, Czech, Dutch
• Parallel test sockets for devices under test without mains plug
• Safety for the user thanks to integrated personal protection − suitable for persons with basic electro-technical
instruction
• DKD calibration certificate (optional)
Options:
• Mains connectors for England, France, Germany, Italy, Switzerland, Denmark, USA, China, Australia and adapter set
• High-voltage test
• 25 AAC test current for protective conductor measurement
• DBmed database, modem operation, remote control, direct printing
• Configuration in accordance with customer specifications
• Measurements in accordance with EN 60601, calibration certificate
• 10 test sockets for patient application parts
• 2 test sockets for equipotential bonding conductor / operational earth electrode
• Configuration for safety class 2 hospital beds (preset)
• Software: PS 3, PC.doc-WORD/-ACCESS, ELEKTROmanager
• Dimensions: 292 x 130 x 243 mm, weight: 4.5 kg
● Included:
SECUTEST SIII – standard models (available from stock) including:
M7010-V010: SECUTEST SIII for Germany with all basic features (B00 through L00)
M7010-V001: SECUTEST SIII for Germany, additionally with B01 service socket
and J01 patient ports
● See optional accessories on page 75.
● See characteristic values on next page.
SECUTEST SIII with Optional PSI Module
SECUTEST PSI
Made in Germany
➲ See page 91 for training seminar:
GTT1211, GTT1212, GTT1213, GTT1214, GTT1216, GTT1224A, GTT1224D, GTT1224F, GTT1226
Type
Data Sheet No.
Article Number
M7010-V010
3-349-112-03
M7010-V010
M7010-V001
3-349-112-03
M7010-V001
SECUTEST SIII basic instrument, = features 00
3-349-112-03
M7010
Service outlet
3-349-112-03
M7010B01
Adapter set for international use
3-349-112-03
M7010B11
SECUTEST PSI printer module
3-349-112-03
M7010E01
HV test, setpoint: max. 4 kV AC
3-349-112-03
M7010F02
25 A 50/60 Hz AC test current
3-349-112-03
M7010G01
Patient ports
3-349-112-03
M7010J01
Measurements per EN 60601/IEC 601
3-349-112-03
M7010KA01
Integrated database
3-349-112-03
M7010KB01
Data transmission via modem
3-349-112-03
M7010KC01
Acoustic signaling via software+SK5
3-349-112-03
M7010KD01
Direct printing
3-349-112-03
M7010KE01
Calibration certificate per DKD
3-349-112-03
M7010L01
F2000 universal carrying pouch
3-349-126-02
Z700D
K2010 carrying case
–
Z504L
WZ12C clip-on current sensor
3-349-017-03
Z219C
Z864A shunt
–
Z864A
Z3409 Pt100 temperature sensor
–
GTZ3409000R0001
57
Testers –
DIN VDE 0701/0702/0751
IEC EN 60601/60335/60950/61010
SECUTEST Slll − Characteristic Values
Measured Quantity
Measuring Range /
Nominal Range of
Use
Device protective conductor resistance RPE
1 mΩ
2.11 ... 31.00 Ω
10 mΩ
1 kΩ
1.01 ... 10.00 MΩ
10 kΩ
10.1 ... 310.0 MΩ
8
> 1 mA
< 10 mA
—
±(5% rdg.+ 10 d)
±(2.5% rdg.+ 5 d)
> 10 D
> 10 digits
—
±(5% rdg.+10 d)
±(2.5% rdg.+5 digits)
±(10% rdg.+10 d)
±(10% rdg.+10 dig-
2 kΩ
±(5% rdg.+10 d)
±(2.5% rdg.+5 digits)
—
> 10 digits
0 ... 3.500 mA
1 μA
—
—
—
—
2 kΩ
—
±(5% rdg.+10 d)
±(2.5% rdg.+5 digits)
0.000 ... 3.100 mA
3.00 ... 31.00 mA
1 μA
10 μA
—
—
—
—
—
—
±(10% rdg.+10 d)
±(5% rdg.+5 digits)
> 10 digits
> 10 digits
0.0 ... 310.0 μA
0.1 μA
—
230 V
–20 /
+10%
—
110% of
highest line
voltage 6
—
—
0.000 ... 2.100 mA
1 μA
2.101 ... 21.00 mA
10 μA
100 μA
0.0 ... 310.0 μA
100 nA
Total leakage current
IABL
0.210 ... 3.600 mA
1 μA
3.10 ... > 15.00 mA
10 μA
Measured Quantity Measuring Range /
Nominal Range
range
Resolution
OpenCircuit
Voltage
U0
< 3.5 mA > 72 kΩ
< 3.5 mA > 72 kΩ
—
ShortCircuit
current
IK
1 kΩ
> 10 digits
> 10 digits
1 kΩ
±50 Ω
±(5% rdg.+10 d)
±(2.5% rdg.+5 digits)
—
±(5% rdg.+10 d)
±(2.5% rdg.+5 digits)
Measuring Error
Intrinsic Error
Internal
Resistance
RI
253 V
Time
Cont.
No protection 5
253 V
Cont.
253 V
Cont.
its)
—
20.1 ... 120.0 mA
Function Test
7
1.0 • UN ...
1.5 • UN
—
—
Overload Capacity
Value
230 V
–20 /
+10%
> 10 digits
> 10 digits
253 V
1
253 V
253 V
Cont.
2
1
Cont.
1, 3
Cont.
1, 3
Overload Capacity
Value
Time
Line voltage UL–N
103.5 V ... 126.5 V
207.0 ... 253.0 V
0.1 V
—
—
—
—
±(2.5% rdg.+5 digits)
253 V
Cont.
Load current IL
0 ... 16.00 A RMS
10 mA
—
—
—
—
±(2.5% rdg.+5 digits)
20 A
10 min.
Active power P
0 ... 3700 W 8
1W
—
—
—
—
±(5% rdg.+10 digits)
253 V
Cont.
> 20 digits
20 A
10 min.
Apparent power S
0 ... 4000 VA
1 VA
Calculated value, UL–N • IV
0.00 ... 1.00
0.01
Calculated value, P / S, display > 10 W
1
1
253 V
Cont.
Cont.
±(5% rdg.+10 digits)
> 20 digits
Power factor LF
Voltage
6
50 ...
500 V DC
> 10 A
AC4 >5 s
—
—
Intrinsic Error
—
between L and N
per DIN VDE 0702
5
< 6 V AC
Reference Measuring Error
Resistance
RREF
10 μA
with sinusoidal
waveshape: cos ϕ
Residual current ΔI
4
—
> 200 mA
DC
—
Internal
Resistance
RI
100 μA
Leakage current IABL 2
Function
4.5 ... 9 V
DC
Nominal ShortCurrent Circuit
IN
Current
IK
0.00 ... 21.00 mA
Equivalent device or
patient leakage current
IEGA or IEPA
3
100 kΩ
—
OpenCircuit
Voltage
U0
20.1 ... 120.0 mA
Contact current
(absence of voltage)
IProbe
2
1 mΩ
0.050 ... 1.500 MΩ
Equivalent leakage
current IEL
1
Nominal
Voltage
UN
0.000 ... 2.100 Ω
0.000 ... 2.100 Ω
Insulation resistance
RISO
Residual current ΔI
between L and N
per DIN VDE 0702
Resolution
10 μA
—
—
—
0 ... 253.0 V
, and
0.1 V
—
—
—
0.00 ... 31.00 mA
Extra-low voltage,
safety class III
UProbe
Probe voltage
0 ... 253.0 V
, and
0.1 V
—
—
R
Resistance
0 ... 150.0 kΩ
100 Ω
< 20 V –
1.1 mA
0.000 ... 10.00 A
1 mA
—
IClip
Current via
Clip-on currentVoltage transformer
WZ12C
0 ... 100 A
1A
Temp
Temperature
with Pt100/Pt1000
sensor
> 10 digits
±(5% rdg.+10 d)
±(5% rdg.+5 digits)
±(2.5% rdg.+5 digits)
> 10 digits
—
±(2.5% rdg.+5 digits)
> 10 digits
253 V
—
—
±(1% rdg.+3 digits)
253 V
Cont.
—
1.5 MΩ
—
±(3% rdg.+10 digits)
253 V
Cont.
—
—
1.5 MΩ
—
> 10 digits
without clip
253 V
Cont.
Cont.
1.1 mA
—
—
±(2% rdg.+1° C)
±(1% rdg.+1° C)
±(2% rdg.+1° C)
10 V
< 20 V –
10 V
Cont.
10 V
Cont.
1° C
– 50.1 ... + 300.0° C 0.1° C
+300 ... +850° C
±(10% rdg.+10 d)
—
UAC/DC
– 200 ... – 50° C
±(10% rdg.+5 digits)
1° C
As of 25 mA: shutdown within 100 ms as a result of differential current measurement
Exception: earth leakage current, only 0.000 … 3.100 mA
The measuring path becomes highly resistive, indication appears at the display
Measurement with AC test current is not possible at sockets 1 through 3; feature G01: > 25 A; when using the SK5 probe cable, short-circuit current is less than 25 A.
Maximum test duration: 40 seconds, protection against overheating: measurement cannot be restarted until after waiting for 1 minute.
Calculated value
AC and DC are measured in the case of patient leakage and patient auxiliary current.
Measured value P and calculated value S are compared, and the smaller of the two is displayed.
Key:
58
rdg. = reading (measured value), d = digit(s)
IABL = Patient, housing and earth leakage current, as well as patient auxiliary current
Made in Germany
Testers – DIN VDE 0701/0702, Test Instrument Accessories
SECUTEST 3PL
Test Instrument for Periodic Testing at Single and 3-Phase Devices in Accordance with
DIN VDE 0701 and DIN VDE 0702
Testing electrical safety of electrical equipment per BGV A3, GUV-V A2
The test instrument is used for fast, safe periodic testing of electrical devices in accordance with DIN VDE 0701 and
DIN VDE 0702. The following are measured in accordance with the regulations:
• Protective conductor resistance, insulation resistance, protective conductor current for SC1 devices, contact current
for SC2 devices, absence of voltage at exposed conductive parts (= contact current)
Measuring methods:
• Direct measurement, equivalent leakage current, differential current
Testing the electrical safety of extension cables
• Protective conductor resistance, insulation resistance, continuity, short-circuit and reversed polarity
Function test with power analysis for single phase DUTs
Suitable for high power DUTs with up to 16 A.
The device under test can be subjected to a function test with mains voltage via the integrated single pole earth contact
outlet. The function test can be executed immediately after electrical safety testing has been successfully completed.
The following are measured, or calculated automatically:
• Line voltage, differential current, current consumption, active and apparent power, power factor, electrical energy
and duty cycle
Report generating functions
All of the values required for approval reports or device logbooks for electrical equipment (e.g. per ZVEH) can be measured
with this instrument. All measured data can be documented and archived thanks to the measurement and test report which
can be printed from, or stored to a PC.
● Included:
Test instrument with automated test sequence, interface, online instructions in German, extensive
connection options with plug connectors, probe cable with test probe and plug-on alligator clip, test report,
operating instructions and condensed operating instructions
➲ See page 91 for training seminar: GTT5010
SECUTEST PSI
Type
Data Sheet No.
Article Number
SECUTEST 3PL
–
M704B
DKD calibration certificate
–
–
Integratable Printer/Memory Module for SECUTEST..., PROFITEST 204, METRISO 5000D-PI
and MAVOWATT 45 for Rapid On-Site Report Generation
Test results are transmitted via ribbon cable to the PSI module, which can be integrated into the instrument’s lid,
and are automatically saved to memory. All measured values for 200 to 1000 test reports can be stored to this
memory. Test results can be printed out on-site in the form of concise, documented reports which can be
furnished with date, time and text entered at the keypad.
• Dimensions: 240 x 81 x 40 mm (without knurled screws and ribbon cables), weight: approx. 0.8 kg
• Batteries: 4 ea.1.5 V IEC LR 6 (AA mignon) if operated with batteries
Consumable materials: PS-10P = pack of 10 six meter recording charts, Z3210 = pack of 10 printer ribbon cartridges
.
Z745A CEE adapter
Type
Data Sheet No.
Article Number
SECUTEST PSI
3-348-785-03
GTM5016000R0001
PS-10P
3-348-785-03
GTZ3229000R001
Z3210
3-348-785-03
GTZ3210000R001
Adapter for 3-Phase Consumers
The Z745A CEE adapter allows for quick and efficient testing of devices equipped with a CEE plug in accordance
with VDE 0701/0702.
• CEE attachment outlets: 16 A/3-pole, 16 A/5-pole, 32 A/5-pole
• Safety outlets for 3-phase devices without permanently attached plug
• Protective conductor continuity test and insulation test for each phase, and combined phases, with rotary switch
Made in Germany
Type
Data Sheet No.
Article Number
Z745A
–
Z745A
59
Testers – DIN VDE 0701/0702, Test Instrument Accessories
VL2 Test Adapter
Test Adapter for Testing Devices and Extension Cables
with Test Instruments for DIN VDE 0701/0702
The test adapter is intended for the performance of measurements and testing at electrical devices and
extension cables with CEE plug connectors in combination with test instruments in accordance with the
following standards:
DIN VDE 0701-1:2000 (testing after repair)
DIN VDE 0702 (periodic testing).
The following quantities can be tested with the adapter in combination with test instruments which are intended
for the performance of the respective tests:
Electrical devices
• Protective conductor resistance
• Insulation resistance (measurement of L1, L2, L3 and N short-circuited to PE)
• Equivalent leakage current
Extension cables
• Protective conductor resistance
• Insulation resistance (measurement of L1, L2, L3 and N short-circuited to PE)
• Easy function test for single and 3-phase extension cables including testing for conductor continuity, short circuiting
and polarity reversal (clockwise rotation) with rotary selector switch
.
SECU-cal 10
Type
Data Sheet No.
Article Number
VL2
3-349-241-03
Z600B
Calibration Adapter for SECUTEST, METRATESTER, MINITEST and SECUSTAR
The calibration adapter is used for testing test instruments per DIN VDE 0701/0702 for measuring safety.
As a rule, these instruments must be tested once each year, as well as for certification in accordance with the ISO 9000
quality standard, as set forth by accident prevention regulation BGV A3 (VBG 4).
All limit values for the required tests per DIN VDE, as well as protective conductor resistance, insulation resistance,
equivalent leakage current, and residual and/or contact current must be tested.
SK2
SK5
Type
Data Sheet No.
Article Number
SECU-cal 10
–
Z715A
Probe Cable for Protective Conductor Measurement
SK2: test probe and 2 m cable without spiral, suitable for high-voltage testing, for SECUTEST...
SK5: software for acoustic signaling including 5 m probe cable, for SECUTEST...
• 5 meter probe cable for protective conductor measurement
• Automatic recognition of changing measuring points as software upgrade on floppy disk
• Go/No-Go indication with various displays
Clip-On Current Sensor
Type
Data Sheet No.
Article Number
SK2
–
Z745D
SK5
–
Z745K
Clip-On Current Sensor for Easy, Safe Measurement of Current Flowing within a Conductor
The following advantages result:
• Electrical circuits need not be interrupted
• No electrical connection to the conductor
• Measurement of current up to 2000 A
• No multimeter overloading as a result of current surges
Measuring Range
CAT at V
CrossSection
Transformation Ratio
Frequency
Range
Intrinsic Error
± (% rdg. + mV/A)
WZ12C 1 mA ... 15 A AC,DC
1 A ... 150 A AC
III at 300
15 mm dia.
1 mV/mA
1 mV/A
45...65 ...500 Hz
3%+0.15 mA
2%+0.1 A
Type
60
Type
Data Sheet No.
Article Number
WZ12C
3-349-017-03
Z219C
Made in Germany
Testers – DIN VDE 0701/0702, Test Instrument Accessories
Brush Probe
Brush Sensor for SECUTEST, METRATESTER, MINITEST and SECUSTAR
Contacting for:
• Leakage current measurement (contact current)
• Protective conductor resistance measurement
The brush probe is suitable for contacting exposed conductive parts which rotate during operation, e.g. drill chucks,
vibrating sanders and tool mounts.
The brush must be plugged onto test probe.
PA 4
Type
Data Sheet No.
Article Number
Brush probe
–
Z745G
Patient Connector Cable for SECUTEST SIII
Patient connector cable, 1.5 meters long, 12 conductors each with 4 mm plug
AT3-IIS Safety Tester
Type
Data Sheet No.
Article Number
PA4
–
Z745L
Test Adapter for Connection to SECUTEST SII (with feature F01), and SIII Test Instruments
for Tests per DIN VDE 0701, 0702, 0751
The safety tester is used in combination with SECUTEST test instruments for testing 3-phase devices after repair
(DIN VDE 0701), as well as for periodic testing (DIN VDE 0702).
It allows for fully automated or manual testing in accordance with the menu-driven test sequences included with
the test instruments, with transmission of test results to, and analysis at SECUTEST test instruments.
Test types:
DIN VDE tests without mains operation
• Protective conductor resistance, insulation resistance, equivalent leakage current
DIN VDE tests with mains operation
• Differential current, contact current
• Equipped with 5-pole CEE 32 A (max. 20 A) and CEE 16 A
• Dimensions: 290 x 120 x 105 mm (without cables and grommets), weight: 2.4 kg
AT3-IIIE Safety Tester
Type
Data Sheet No.
Article Number
AT3-IIS
–
Z745T
Test Case for Connection to SECUTEST SII (with feature F01) and SIII Test Instruments
for Testing in Accordance with DIN VDE 0701, 0702 and 0751
The safety tester is used for measuring and testing single and 3-phase electrical devices and extension cables
in combination with SECUTEST SII and SIII test instruments. These tests must be performed by a qualified
electrician with an appropriate test instrument after repair or modification in accordance with DIN VDE 0701, and
are also required for periodic testing per DIN VDE 0702 or 0751.
According to these regulations, protective conductor resistance, insulation resistance, equivalent leakage
current and differential current must be measured, depending upon the device under test and its application.
Testing per EN 60601-1 is only possible to a certain extent.
• Connection of single and 3-phase devices and extension cables without reconnecting devices under test in
operating modes with and without mains power via the test sockets and the test plug at the AT3-IIIE
• Tests according to menu-driven test sequences included with SECUTEST test instruments, fully automatic or manual
• Transfer of test results to test instruments with evaluation performed by SECUTEST series test instruments
• Additional protection provided by electronic residual current monitoring with mains disconnect for defective devices
under test for fault currents of greater than 20 mA, and optical error indication
• Trip control with “residual current tripping” test key
• Prevention of short-circuits and blown mains fuses during testing of defective single and 3-phase extension cables
• The EL1 adapter function (SECUTEST test instrument accessory) for testing single phase extension cables is
included with the AT3-IIIE as an integral component.
• Dimensions: 405 x 300 x 220 mm (with lid), weight: approx. 6.7 kg
Made in Germany
Type
Data Sheet No.
Article Number
AT3-IIIE
3-349-156-03
Z745S
61
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
METRAOHM 413
Digital Low-Resistance Measuring Instrument
Digital low-resistance measuring instrument in accordance with DIN VDE 0 413 part 4 and EN 61 557 parts 1 and 4
•
•
•
•
•
•
Two measuring ranges: 0.01 ... 20 Ohm / 0.1 ... 200 Ohm
Zero balancing for measurement cables
Compact and rugged – for service calls and laboratory use
Overvoltage protection – protects the instrument in the event of inadvertent connection to mains power
Indication of interference voltage
IP 65 protection
● Included:
Low-value resistance measuring instrument, 1 plug-in measurement cable,
9 volt block battery per IEC 6 LR61, operating instructions
● Optional Accessories: F837: ever-ready case for METRISO 500D, 1000D, 1000IR ...,
Telearm 1: telescoping rod for PE measurement,
TR50: metal drum with 50 m measurement cable,
TR25: reel with 25 m measurement cable (see also as of page 75)
.
METRISO C
Type
Data Sheet No.
Article Number
METRAOHM 413
3-348-810-03
M630A
Digital Insulation and Resistance Measuring Instrument, 1000 V
The following functions are included for measurements in electrical systems, as well as at insulating and
conducting floor coverings and walls:
• Measurement of insulation resistance and high-resistance with display of the measured value and the actual,
respective measuring voltage
• Measurements at bonding and protective conductors with low-resistance measurement
• Measurement of contact current, voltage and frequency
• Optional measurement of temperature and relative atmospheric humidity
• All measurements are in compliance with the following regulations:
DIN VDE 0100 part 610, DIN VDE 0413 (=EN 61557) parts 1, 2, and 4, DIN VDE 0701 part 240,
EN 344, EN 1081, IEC 1340-4-1, IEC 1340-5-1
• Unambiguous limit value and Go/No-Go indication by means of LEDs, and display of useful information
• All measurement values are stored to memory with reference to their respective electrical circuit designations
• Rugged 2-component housing for everyday use
• Dimensions: 275 x 140 x 65 mm (H x W x D), weight: 1.2 kg with batteries
• Power supply: 4 ea. mignon cell per IEC LR 14
● Included:
M541A: Insulation measuring instrument with factory calibration certificate
M508A: Set consisting of PROFiTEST C, METRISO C, 3-pole adapter, IrDa 0100 adapter cable
and KS17 measurement cables, in HC 40 hard case
● Optional accessories: Charger for NA 0100S battery set, HC30-C hard case as of page 75, special KS-C
cable set including 1 measurement cable and 1 high-resistance measurement cable
● Optional software:
PS3 – software for test instruments:
systems and equipment management, and report generation (see page 77)
➲ See page 91 for training seminar: GTT1210, GTT1224B, GTT1224G, GTT1226
Characteristic Values
62
Function
Measuring Range
Measuring Voltage
Insulation resistance R ISO
000 kΩ ... 99.9 GΩ
100 V ... 1000 V
1 mA (RN =1 kΩ/V)
Resistance R LO
0.00 Ω ... 99.9 Ω
4.5 V (U0 )
≥ 200 mA (R < 10 Ω)
Voltage U ISO / U∼
0 V ... 1200 V
–
–
Contact current IB
0.00 mA ... 9.99 mA
–
–
Type
Data Sheet No.
METRISO C
3-349-086-03
M541A
Set PROFiTEST C/METRISO C
3-349-086-03
M508A
KS-C
–
Z541F
Nominal Current
Article Number
Made in Germany
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
METRISO ® 500D
Digital Insulation Measuring Instrument, 500 Volt
Traditional digital insulation measuring instrument for electrical systems with up to 500 V per EN 61 557 parts
1, 2 and 4 (DIN VDE 0413 parts 1 and 4), with 500 V measuring voltage
• Digital and analog display
• Warning for hazardous shock voltages
• Quick-test with signal lamp in test probe
• Measuring voltage: 500 V
• Measuring ranges up to 30 GΩ
• Low-resistance measurement to 30 Ω per DIN VDE 0413, part 4
● Included:
Insulation measuring instrument with permanently connected measurement cables,
2 plug-on alligator clips, 1 carrying strap with 2 test probe holders,
1 set of batteries (6 mono-cells), 1 replacement fuse, operating instructions
● Optional Accessories: F837: ever-ready case for METRISO 500D, 1000D, 1000IR ...,
Telearm 1: telescoping rod for PE measurement,
TR50: metal drum with 50 m measurement cable,
TR25: reel with 25 m measurement cable,
KS24: cable set for test instruments (see also as of page 71)
.
METRISO ® 1000D (1000IR)
Type
Data Sheet No.
Article Number
METRISO 500D
3-349-115-03
GTM5040000R0001
F837 ever-ready case
–
GTZ3312000R0001
DKD calibration certificate
–
–
Digital Insulation Measuring Instrument, 1000 Volt
Digital insulation measuring instrument for electrical systems with up to 1000 V per EN 61 557 parts 1, 2 and 4
(VDE 0413 parts 1 and 4)
• Digital and analog display
• Three nominal voltages: 100 V (1000IR: 250 V), 500 V, 1000 V
• Warning for hazardous shock voltages
• Voltage measurement to 1000 V
• Quick-test with signal lamp in test probe
• Low-resistance measurement per DIN VDE 0413, part 4
• Three measuring voltages: 100 V, 500 V, 1000 V
• Measuring ranges up to 30 GΩ
• Low-value resistance measurement up to 30 Ω
● Included:
Insulation measuring instrument with permanently connected measurement cables,
2 plug-on alligator clips, 1 carrying strap with 2 test probe holders,
1 set of batteries (6 mono-cells), 1 replacement fuse, operating instructions
● Optional Accessories: F837: ever-ready case for METRISO 500D, 1000D, 1000IR ...,
Telearm 1: telescoping rod for PE measurement,
Sonde 1081: floor probe,
TR50: metal drum with 50 m measurement cable,
TR25: reel with 25 m measurement cable,
KS24: cable set for test instruments (see also as of page 75)
.
Characteristic Values
Type
Display
Insulation resistance
Number of ISO measuring ranges
Intrinsic error
Max. nominal voltage
Nominal current
Limit value signal Signal lamp
Acoustic
Low-resistance measuring range
Voltage (AC / DC)
Power Supply
Dimensions
Weight
METRISO 500D
Digital
0 ... 3 GΩ
6
Made in Germany
500 V
●
●
0 to 500 V
Type
Data Sheet No.
Article Number
METRISO 1000D
3-349-115-03
GTM5050000R0001
METRISO 1000IR
3-349-115-03
GTM5050000R0002
F837 ever-ready case
–
GTZ3312000R0001
DKD calibration certificate
–
–
METRISO 1000 D
METRISO 1000 IR
0 ... 30 GΩ
7
± (1.5% + 2 digits)
100 V/500 V/1000 V
250 V/500 V/1000 V
1 mA
●
●
●
●
0.1 ... 30 Ω
0 ... 1000 V
0 ... 1000 V
6 ea. 1.5 V mono-cell, IEC R 20
165 x 125 x 110 mm
1.85 kg
METRISO 1000 A
Analog
0 ... 400 MΩ
15
METRAOHM 413
Digital
–
± (1.5% + 4 digits)
50 V ... 1000 V
≥ 1 mA / 200 mA
●
–
0 ... 4 Ω
0 ... 1000 V
1.6 kg
200 mA (20 mA)
●
●
0.01...20 Ω (200 Ω)
Interference voltage display
1 ea. 9 V block, IEC 6 LR 61
60 x 230 x 40 mm
0.25 kg
63
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
METRISO ® 5000D-PI
Digital High-Voltage Insulation Measuring Instrument to 5000 V DC
Instrument for traditional insulation measurement with selectable voltages of up to 5000 V –,
designed for all known types of long-term insulation measurement as well
Features
Test Voltages to 5000 V
The instrument is suitable for non-destructive measurement of insulation resistance in electrical systems, as well as at
machines, transformers, cables and electrical equipment utilized in, for example, locomotives, street cars and ocean going
vessels, with selectable test voltages of up to 5 kV.
Voltage Measurement to 1000 V
Testing for absence of voltage at the device under test in systems of up to 1 kV can be performed with the voltage
measuring range.
Discharging Capacitive Devices Under Test
Capacitive devices under test such as cables and coils, which may be charged by the test voltage, are discharged by the
measuring instrument. The falling voltage value can be observed at the display.
Measurements per EN 61 557 Parts 1 and 2 (VDE 0413)
Nominal current amounts to 1 mA at a test voltage of 100 V, 250 V, 500 V or 1000 V.
Highly Insulated Measuring Cables
The highly insulated measuring cables are permanently connected for safety reasons, and as a result of technical measuring
considerations. Danger resulting from an inadvertently disconnected cable, for example in the event of charging caused by
capacitive devices under test, is thus avoided.
Polarization Index
A polarization index test is recommended for electrical machines. This procedure involves expanded testing of insulation resistance. DC measuring voltage from the METRISO®5000 D-PI is applied to the insulation for a duration of 10 minutes. Measured values are documented after one minute, and after ten minutes. If the insulation is good, the value measured after ten
minutes is higher than the value measured after one minute. The relationship between the two measurement values is the
polarization index. Charged material within the insulation is aligned due to the application of measuring voltage over a long
period of time, resulting in polarization. The polarization index indicates whether or not the charged material contained in the
insulation can still be moved, thus allowing for polarization. This, in turn, is an indication of the condition of the insulation.
METRISO 5000D-PI with Optional PSI Module
SECUTEST PSI
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Extensive measuring range from 0.1 MΩ to 1 TΩ
Variable test voltage, or in fixed steps: 100 V, 250 V, 500 V, 1 kV, 1.5 kV, 2 kV, 2.5 kV, 5 kV
Polarization index and absorption ratio
Voltage measurement to 1000 V
Frequency measurement from 15 Hz to 1 kHz
Capacitance measurement from 0.1 to 5 μF
Measurement of electrical discharge
Guard terminal for the elimination of surface current
5 m extension cable as accessory
Supply power from mains, battery pack or external 12 V power supply
Backlit dot matrix display
Digital display of measured values and limit values, characteristic curve display for polarization index
Timer function: 1 s to 100 min.
DKD calibration certificate
● Standard equipment for standard models (available from stock) including: M5810-V001: M5810 with German
online instructions (A01) and rechargeable battery (C1), including DKD calibration certificate
● Specify the designation of the basic M5810 instrument in your order, as well as any features which deviate
from feature 0.
Online instructions also in 2 languages: A02 = international English, A04 = French, A05 = Dutch,
A07 = Spanish, A10 = Italian, A14 = Czech, A15 = Swiss German, A43 = American English
Optional Accessories
● Optional accessories: DA-II: printer adapter for connection of printers with Centronics interface,
KY 5000A: 2 alligator clips (5kV version), ISO calibrator 1: calibration adapter for test
voltages up to 1000 V and F2000 carrying pouch (see also as of page 75)
.
Guard 5000A
KY 5000A
F2000
64
DA-II
Type
Data Sheet No.
Article Number
METRISO 5000D-PI
3-349-209-03
M5810-V001
METRISO 5000D-PI
Basic instrument = all features 00
3-349-209-03
M5810
PROFITEST 204HP/2.5 kV (not with C1)
3-348-802-03
M5810B1
PROFITEST 204HP/5.4 kV (not with C1)
3-348-802-03
M5810B2
Rechargeable battery (not with B1, B2)
–
M5810C1
M5810D1
Caddy 2047 (not with B0)
3-348-802-03
Signal 204, external signal lamp
3-348-802-03
M5810F1
Guard 5000A, measurement cable
–
M5810G1
LEADEX 5000, 5 m extension cable
–
M5810H1
SECUTEST PSI, printer module
3-348-785-03
M5810I1
DA-II
–
Z745M
KY 5000A
–
Z580B
ISO calibrator 1
–
M662A
F2000 carrying pouch
3-349-126-02
Z700D
Made in Germany
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
METRISO ® 1000A
Analog Insulation Measuring Instrument, 1000 Volt
Low-cost analog insulation measuring instrument for electrical systems with up to 1000 V in accordance with
EN 61 557 parts 1, 2 and 4 (DIN VDE 0413 parts 1 and 4)
• Five nominal voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
• Voltage measurement to 1000 V
• Signal lamp for battery level
• Low-resistance measurement per DIN VDE 0413, part 4 / EN 61557 -1 / -2 / -4
● Included:
Insulation measuring instrument with carrying pouch, operating instructions
● Optional Accessories: F837: ever-ready case for METRISO 500D, 1000D, 1000IR ...,
Sonde 1081: floor probe,
KS24: cable set for test instruments (see also as of page 75)
.
METRISO ® 5000A
Type
Data Sheet No.
METRISO 1000A in carrying pouch
3-348-807-03
Article Number
M540C
KS24 extension cable
–
GTZ3201000R0001
1081 probe
–
GTZ3196000R0001
F837 ever-ready case
–
GTZ3312000R0001
Factory calibration certificate
–
–
Analog Insulation Measuring Instrument, 5000 Volt
METRISO 5000A: analog high-voltage insulation measuring instrument with 4 measuring voltages: 100, 250, 500
and 1000 V (per EN 61 557 part 2) and 1500, 2000, 2500 and 5000 V
METRISO 5000AK: The battery powered METRISO 5000 A is converted into the muscle powered
METRISO 5000AK by replacing the battery module with a crank generator.
• Extensive measuring range: 10 kΩ ... 1 TΩ
• Measuring range: 100 kΩ ... 100 MΩ (1000 V)
• Measuring voltages: 100 V, 250 V, 500 V, 1000 V, 1500 V, 2000 V, 2500 V, 5000 V
• Measurements to 1000 V per DIN VDE 0413
• Voltage measurement to 2000 V ,
• Concise logarithmic display
• Guard terminal for the elimination of surface current
● METRISO 5000A:
METRISO 5000A
Generator 5000A
High-voltage insulation measuring instrument with permanently connected
measurement cables and test probes, 2 alligator clips (5 kV version) and battery
module including batteries, 1 carrying strap, operating instructions
METRISO 5000AK:
High-voltage insulation measuring instrument with permanently connected
measurement cables and test probes, 2 alligator clips (5 kV version) and crank
generator, 1 carrying strap, operating instructions
METRISO 5000A set: METRISO 5000A + KY 5000A + GUARD 5000A in F2000 universal carrying pouch
METRISO 5000AK set: METRISO 5000AK + KY 5000A + GUARD 5000A in F2000 universal carrying pouch
● Optional accessories: 5000A generator: crank generator for Metriso 5000A,
KY 5000A: 2 alligator clips for Metriso 5000A,
Guard 5000A: 1 guard cable and 1 alligator clip for METRISO 5000A,
Leadex 5000: 5 m extension cable,
F2000 carrying pouch (see also as of page 75)
Technical Data:
Type
METRISO 5000AK
Made in Germany
METRISO 5000A
Insulation resistance
Open-circuit voltage
Voltage (AC / DC)
Power supply
Dimensions
Weight
1 TΩ
100 V, 250 V, 500 V, 1000 V, 1500 V, 2000 V, 2500 V, 5000 V
0 ... 2000 V
6 ea. 1.5 V mono-cell, IEC R 20 (D size)
290 x 250 x 140 mm
3.4 kg (with batteries)
Type
Data Sheet No.
METRISO 5000A
3-348-858-03
Article Number
M580A
METRISO 5000AK
3-348-858-03
M580C
METRISO 5000A-Set
3-348-858-03
M580S
METRISO 5000AK-Set
3-348-858-03
M580T
Generator 5000A
3-348-858-03
Z580A
KY 5000A
–
Z580B
Guard 5000A
–
Z580C
Leadex 5000
–
Z580D
F2000 carrying pouch
3-349-126-02
Z700D
Factory calibration certificate
–
–
65
Insulation Measuring Instruments – VDE 0413 / EN 61557-1/-2
METRISO 5024
Analog Insulation Measuring Instrument / Low-Resistance Measuring Instrument /
Voltmeter with Buzzer
The analog insulation measuring instrument for quick two-hand operation in accordance with VDE 0413,
parts 1, 2 and 4, and voltmeter
• Insulation measurement with 100, 250 and 500 V measuring voltages
• With analog display
• Low-resistance measurements for protective conductor and equipotential bonding conductor resistance, and continuity
• Buzzer indicates alarm status for erroneous and implausible measurements, blinking LED serves same purpose
• Fluttering pointer as last resort warning function
● Included:
Insulation and resistance measuring instrument with carrying pouch, replacement fuse,
operating instructions
● Optional accessories: KS24 cable set for test instruments, ISO calibrator 1: calibration adapter
See also as of page 75.
Characteristic Values:
Insulation measurement, measuring voltage: 100 / 250 / 500 V
Measuring Range
Intrinsic Error
Overload
0.1 … 400 MΩ
2.5%
600 V AC
Measuring Current Short-Circuit Current
> 1 mA
< 10 mA
* Measuring error under reference conditions relative to scale length (l = 84.6 mm)
Low resistance measurement, measuring voltage: 4.5 V
Measuring Range
Intrinsic Error
Overload
Measuring Current
0…4Ω
2.5%
250 V DC
> 200 mA
* Measuring error under reference conditions relative to upper range value (l = 74.9 mm)
Voltage measurement, DC / AC (40 … 200 Hz)
Measuring Range
Intrinsic Error
Overload
Internal Resistance
0 … 500 V
2.5%
600 V AC
450 kΩ
* Measuring error under reference conditions relative to scale length (l = 73.3 mm)
Mechanical Design:
IP 40 protection per DIN VDE 0470, part 1 / EN 60 529, dimensions: 98 x 310 x 40 mm, weight: approx. 0.5 kg with batteries
Power Supply:
Batteries: 4 ea. 1.5 V mignon batteries per IEC LR6 (4 ea. size AA)
ISO CALIBRATOR 1
Type
Data Sheet No.
METRISO 5024 in pouch
3-349-212-03
Article Number
M540E
KS24
–
GTZ3201000R0001
ISO calibrator 1
–
M662A
Calibration Adapter for Insulation and Resistance Measuring Instruments
Calibration adapter for rapid, efficient testing of the accuracy of measuring instruments for insulation resistance
and low-value resistors
.
66
Type
Data Sheet No.
Article Number
ISO calibrator 1
–
M662A
Made in Germany
Earth Testers – DIN VDE 0413/EN 61557-1/-5
GEOHM C
Battery Powered Earth Tester (also for measurement of soil resistivity)
Compact, menu-driven instrument for the measurement of earthing resistance for 3 or 4-wire connection.
Continuous monitoring of interference voltage, as well as auxiliary earth electrode and probe resistance with
indication if allowable limit values are violated.
Complete display of all required values at a large dot matrix display, or warning with 4 LEDs.
Easy concise operation with only 4 keys.
•
•
•
•
•
•
•
•
•
•
Measurement of earthing resistance in 5 ranges to 50 kΩ
Voltage measurement from 10 to 250 V, frequency measurement from 45 to 200 Hz
Battery monitoring and self-test, integrated memory with IrDA interface, factory calibration certificate
Extremely rugged 2-component housing, earth tester in accordance with DIN VDE 0413, part 5
Measurement of ohmic resistance, automatic measurement of probe and auxiliary earth electrode resistance
Automatic monitoring of interference voltages in the ground
Helpful hints appear plainly at the display, automatic battery monitoring
Storage of all measured values to memory
Dimensions: 275 x 140 x 65 mm (H x W x D), weight: 1.2 kg with batteries
Power supply: 4 ea. mignon cell per IEC LR 14
For the measurement of earthing resistance in electrical systems in accordance with:
• DIN VDE 0100, set-up of power installations with nominal voltages of up to 1000 V
• DIN VDE 0141, grounding in AC systems with nominal voltages of greater than 1 kV
• DIN VDE 0800, set-up and operation of telecommunications systems including data processing equipment
• DIN VDE 0185, lightning protection systems
• DIN VDE 0413 (=EN 61557 ) parts 1 and 5, devices for testing, measuring or monitoring protective measures and
earth resistance
WinProfi PC program for communication with the GEOHM C.
WinProfi is included on the PS3 CD ROM along with the following contents and functions:
• Up-to-date test instrument software
– For loading a different language
– For loading a more up-to-date software version
• Transfer of measurement data between the test instrument and the PC
• Create and edit templates for test reports at the PC, and transfer them to the test instrument
• Create, print and archive test reports at the PC
● Included:
GEOHM C test instrument, neck strap, batteries, WinProfi PC software, comprehensive
operating instructions covering the following topics:
Measurement of earth resistivity
- With description of 3 and 4-wire methods
- With physical considerations regarding the potential gradient area
- Earth electrode resistance of earthing systems of various scope
- Important tips regarding measurements in unfavorable terrain
Measurement of soil resistivity
- With geologic evaluation and calculation of earth electrode resistance
Measurement of ohmic resistance
● Optional accessories: NA 0100S: charger for battery set
HC30-C: hard case with blister inserts for one test instrument with accessories
IrDa-USB converter: IR interface for connection to the USB port of a PC for
transferring data between the PC and the GEOHM C
See also as of page 75.
Type
Data Sheet No.
Article Number
GEOHM C
3-349-088-03
M590A
NA 0100S
–
Z501D
HC30-C
–
Z541C
IrDa-USB converter
–
Z501J
Technical Data:
Function
Resistance
Voltage
Measuring Range
0.01 Ω ... 20 kΩ
Manual: ... 50 kΩ
0 V ... 250 V
Made in Germany
Resolution
Measuring Voltage
Test Current
Accuracy
0.01 Ω ... 10 Ω
Max. 50 VRMS /128 Hz
10 m ARMS ...100 μARMS
±(3% rdg. + 3 d)
–
–
–
–
Operating Error
±(10% + 6 D)
±(16% + 10 D)
–
67
Earth Testers – DIN VDE 0413/EN 61557-1/-5
GEOHM ®33D
Earth Tester with Crank Generator
Earth testers are used for the measurement of earth resistance in electrical systems per DIN VDE 0100, 0141,
0800 and 0185. This measurement is required for the determination of earthing system dimensions.
The testers can also be used for geological ground surveys and for the planning of earthing systems.
Interference voltage and auxiliary earth electrode resistance are continuously monitored.
A signal is generated automatically if allowable limit values are exceeded.
The testers function in accordance with the current-voltage measuring method per DIN VDE 0413 part 7, and in
accordance with the compensation measuring method per DIN VDE 0413 part 5.
• Digital LCD
• Limit value monitoring
• Easy to turn crank generator
• Rugged mechanical design
● Included:
GEOHM 33D earth tester with 4 adapters for connecting cable lugs,
wire ends or banana plugs, operating instructions
● Optional accessories: F833 carrying pouch
Technical Data:
Feature
GEOHM 33D
Discontinued model:
Display
Digital
Only available until current
stock is depleted.
Intrinsic error
0 ... 20 / 200 / 2000 / 20000 Ω
Measuring ranges
± (2% rdg. + 3 digits)
Power supply
Crank generator
Dimensions / weight
.
210 x 128 x 125 mm / 1.4 kg
Type
Data Sheet No.
Article Number
GEOHM 33D
1-2.5-416.02
GTM5033000R0001
F833 carrying pouch
–
GTZ3301001R0001
Description
Type
Data Sheet No.
Article Number
Reel with 25 m measurement cable
TR25
–
GTZ3303000R0001
Drum with 50 m measurement cable
TR50
–
GTY1040014E34
Earth drill, 35 cm long
SP350
–
GTZ3304000R0001
General Accessories for Earth Testers
68
Made in Germany
Accessories for Earth Testers – DIN VDE 0413/EN 61557-1/-5
GEOHM Accessories
E-Set 5
Measuring Accessory Set for Earth Testers
Extensively equipped earth measurement case with space for device and accessories
Earth measurement case consisting of:
• Imitation leather case
• 1 drum with 25 m measurement cable
• 2 drums with 50 m measurement cable each
• 3 measurement cables, 0.5 m each
• 1 measurement cable, 2 m long
• 1 test clamp
• 4 earth drills, 350 mm long
• 1 dust cloth
• 2 pads with forms
GEOHM Accessories
E-Set 3
Type
Data Sheet No.
Article Number
E-Set 5
–
Z590B
Measuring Accessory Set for Earth Testers
Moderately priced measuring accessories for measurements with earth spikes
Contents:
• 2 reels
• 2 measurement cables, 25 m each
• 1 measurement cable, 40 m long
• 2 measurement cables, 3 m each
• 4 earth spikes (zinc plated)
• 2 spike pullers
• 1 hammer
.
GEOHM Accessories
E-Set 4
Type
Data Sheet No.
Article Number
E-Set 3
–
GTZ3301005R0001
Measuring Accessory Set for Earth Testers
Measuring accessories for earth measurements, same as E-Set 3 but with earth drills instead of spikes
Contents:
• 2 reels
• 2 measurement cables, 25 m each
• 1 measurement cable, 40 m long
• 2 measurement cables, 3 m each
• 4 earth drills
.
Made in Germany
Type
Data Sheet No.
Article Number
E-Set 4
–
Z590A
69
Phase Sequence Indicators – EN 61557-1/-7
MetraPhase 1
Phase Sequence Indicator with Electronic Rotary Dial, Frequency Display and Display of
Nominal Line Voltage
Phase sequence indicator with electronic rotary dial, frequency display, nominal line voltage display and phase
sequence indicator in compliance with safety regulations.
We’ve equipped or new METRAPHASE1 phase sequence indicator with an electronic rotary dial which
eliminates mechanical components and saves space.
LEDs arranged in a circular array not only indicate the direction of rotation, but rather line frequency as well by
means of LEDs which light up in various colors.
The presence of voltage at each phase is indicated with additional LEDs, as well as nominal line voltage.
This new phase sequence indicator can be used as a 3-pole or a 2-pole indicator.
• Power supply: 4 ea. mignon cell per IEC LR 6
● Included:
CAT IV.
PhaseCop 2
Phase sequence indicator, 3 plug-in measurement cables with contact-protected plugs,
3 test probes for plugging onto contact-protected plugs, 1 alligator clip for plugging onto
contact-protected plugs, 4 batteries, carrying case, operating instructions
● Optional accessories: GH18: protective rubber cover
Z500A: variable plug adapter set, 3.5 to 12 mm dia., set of 3
NA4/500: power pack, 230 V / 4 V, with safety connector cable
Type
Data Sheet No.
MetraPhase 1
MetraPhase 1
Article Number
M620A
M620A
–
GTZ3212000R0001
GTZ3212000R0001
–
Z500A
Z500A
–
Z218A
Phase Sequence Indicator with LEDs and Contact Protected Plugs
Instrument for determining direction of rotation, or phase sequence in three-phase systems
• 3 LEDs indicate whether or not the 3 phase conductors are live
• Very large voltage and frequency range
• Simple operation, rugged design
• Permanently connected cables with contact-protected connector plugs, three plug-on test probes and one plug-on
alligator clip
● Included:
Phase sequence indicator, 3 permanently connected cables with
contact-protected connector plugs, 3 plug-in test probes,
1 plug-in alligator clip
● Optional accessories: F801: ever-ready case
.
Type
Data Sheet No.
Article Number
PhaseCop 2
3-348-846-03
GTM5202000R0001
F801 ever-ready case
–
GTY3172070P01
Technical Data
Feature
PhaseCop 2
●
LEDs
LED
Phase display
●
●
Display of nominal line frequency
●
-
Display of nominal line voltage
●
-
70 ... 690 V / 50 ... 400 Hz
90 ... 660 V / 45 ... 1000 Hz
84 x 195 x 35 mm
70 x 105 x 38.5 mm
0.3 kg
0.3 kg
Phase sequence display
Nominal range of use
Dimensions
Weight
70
METRAPHASE 1
●
DIN VDE 0413 / EN 61557 compliant
Made in Germany
Test Instrument Accessories
DA-II
RS 232 – Centronics Printer Adapter for Connecting External Printers
• RS 232 – Centronics printer adapter
• Printer driver in SECUTEST Slll for all common printers with parallel interface
• No external power supply required, report generation without PC
A3-16 / A3-32 / A3-63
Type
Data Sheet No.
Article Number
DA-II
–
Z745M
3-Phase Current Adapters
A3-16
A3-xx: A3-16, A3-32 and A3-63 3-phase adapters for connecting test instruments to 5-pole CEE outlets.
The adapters correspond to 5-pole CEE sockets with 16 A, 32 A and 63 A nominal current.
Phase sequence testing with signal lamps, testing the effectiveness of protective measures with five 4 mm contact
protected sockets
A3-32
A3-63
Z500A Variable Plug Adapter Set
Type
Data Sheet No.
Article Number
A3-16
–
GTZ3602000R0001
A3-32
–
GTZ3603000R0001
A3-63
–
GTZ3604000R0001
Variable Plug Adapter set
Self-retaining, contact protected test probes for the connection of measurement cables with 4 mm banana plugs, or with
contact protected plugs for sockets with an opening of 3.5 mm to 12 mm, e.g. CEE, and Perilex sockets.
For example, the test probes also fit the square PE jacks on Perilex sockets.
Maximum allowable operating voltage: 600 V per IEC 61010.
KS13 / KS17-2 / KS24
Type
Data Sheet No.
Article Number
Variable plug adapter set (3 pieces)
–
Z500A
Cable Sets
KS17-2: Cable set with permanently mounted test probes and contact-protected angle plugs for safe measuring.
KS17-2
KS13: Cable set for connecting test instruments such as the METRATESTER 4/5/5-F, SECUTEST 0701/0702S II or
the SECUTEST SII to the mains without using a an earthing contact outlet, and for connecting DUTs.
Consists of coupling socket with 3 permanently connected cables, 3 measurement cables, 3 plug-on pick-up
clips and 2 plug-on test probes.
KS24: The KS24 cable set includes a 4 m long extension cable with a permanently attached test probe at one
end and a contact protected socket at the other end, as well as two alligator clips which can be plugged onto
the test probe.
KS13
KS24
Made in Germany
Type
Data Sheet No.
Article Number
KS13
–
GTY3624065P01
KS17-2
–
GTY3620034P0002
KS24
–
GTZ3201000R0001
71
Test Instrument Accessories
EL1
PRO-... Plug Insert
Adapter for Testing Single-Phase Extension Cables
EL1:
• For testing extension cables
• Earth contact and inlet connector plug inserts included
• Additional country-specific inserts available as well
PRO-CH: plug insert for using the EL1 adapter in Switzerland
EL1
PRO-GB: plug insert for using the EL1 adapter in Great Britain
PRO-RSA: plug insert for using the EL1 adapter in South Africa
PRO-CH
PRO-GB
PRO-RSA
TR25 / TR50
Type
Data Sheet No.
EL1
–
Article Number
Z723A
PRO-CH
–
GTZ3225000R0001
PRO-GB
–
GTZ3226000R0001
PRO-RSA
–
Z501A
TR25: Reel with 25 m Measurement Cable
TR50: Metal Drum with 50 m Measurement Cable
TR25: Reel with 25m measurement cable, cable ends are equipped with banana plugs.
TR50: 50m measurement cable coiled onto a metal drum. Connection to the inside end of the cable is made possible with
a socket integrated into the drum. The other end is equipped with a banana plug.
The drum axle with handle can be removed for space saving storage.
TR25
Z3409 Temperature Sensor
TR50
Type
Data Sheet No.
Article Number
TR25
–
GTZ3303000R0001
TR50
–
GTY1040014E34
Pt100 Temperature Sensor
Standard Z3409 sensor for surface and immersion measurements from -40° C to +600° C
Z3409
Telearm 1, SP350, 1081 Probe
Feature
Sensor element
Sensor element length (I1) mm
Sensor length (I2) mm
Temperature range °C
Accuracy per DIN EN60751/IEC 751
Intrinsic error at 0 °C
Intrinsic error for °C
Transient recovery, T90 water / air
Cable / outer jacket / insulation
Z3409
Pt100
130
1000
– 40...+ 600
Class A
0.15 K
600: 1.35K
5 s / 30 s
Strand, 2 ea. 0.35 sq. mm / PVC
Type
Data Sheet No.
Article Number
Z3409
–
GTZ3409000R0001
Telescoping Rod, Earth Drill, Floor Probe
Telearm1 Telescoping Rod: Telescoping rod with test probe (working length can be locked within a range of 53 to
120 cm), and with a socket in the handle at the other end for quick and safe testing of, for example, lamps installed at
excessive heights for the measurement of protective conductor resistance. Max. allowable voltage to earth: 1000 V.
SP350 Earth Drill: Earth drill, 35 cm long, with connector for 4 mm banana plug.
Can also be used as a probe or auxiliary earth electrode for earth measurements, testing RCCBs etc.
1081 Floor Probe: This metallic tripod-type measurement electrode can be used for:
• Determination of electrical resistance at elastic floor coverings in accordance with EN 1081
• Resistance measurement for insulating floors and walls in accordance with DIN VDE 0100 part 610
72
Type
Data Sheet No.
Article Number
Telearm1
–
GTZ3232000R0001
SP350
–
GTZ3304000R0001
1081 probe
–
GTZ3196000R0001
Made in Germany
Test Instrument Accessories
B3261 Barcode Scanner
Z721D Barcode Printer
Barcode Scanner for Direct Connection to the SECUTEST PSI and the PROFITEST PSI-BC
Barcode and Label Printer with Software
Barcode scanner:
• Trouble-free scanning of all common barcode types
• Insertion of decoded characters to any desired cursor position
• Plug for direct connection to the SECUTEST PSI and the PROFITEST PSI-BC
Barcode printer:
• For the identification of equipment with barcode labels
• Prints smudge-proof, scratch resistant labels in all common sizes
• MS Windows software
• Ideal for use with the B3261 barcode scanner
Label set for Z721D barcode and label printer:
• Z722D, number x width: 3 ea. 24 mm, 1 ea. 18 mm, 1 ea. 9 mm, 8 m long
• Z722E, number x width: 5 ea. 18 mm, 8 m long
.
IrDa-USB Converter
Type
Data Sheet No.
Article Number
B3261 barcode scanner
–
GTZ3261000R0001
Z721D barcode printer
–
Z721D
Z722D label set
–
Z722D
Z722E label set
–
Z722E
IR Interface Adapter for Connecting a Test Instrument to a PC: IrDa-USB
IrDa-USB converter:
Electrically isolated infrared interface for data transmission between test instrument and PC (USB)
Data transfer to and from the IrDa interfaces of our PROFiTEST 0100S-II, PROFiTEST C, METRISO C and GEOHM C test
instruments with modern PCs which are equipped with USB ports only.
● The cable is furnished with a CD ROM including the required device drivers for Windows 98SE,
ME, 2000 and XP.
RS 232 – USB Converter
Type
Data Sheet No.
Article Number
IrDa-USB converter
–
Z501J
Adapter Cable for Connecting the RS 232 Interface to the USB Port at a PC
The interface converter is used to connect any desired device with RS 232 interface to PCs which are equipped
with USB ports only.
● The cable is also furnished with a CD ROM including the required device drivers.
Made in Germany
Type
Data Sheet No.
Article Number
RS 232 – USB converter
–
Z501L
73
Test Instrument Accessories
F2000
K2000, K2010
Universal Carrying Pouch for PROFiTEST 0100S-II, ...204, SECUTEST..., METRISO 5000A/AK
Metal Case for Test Instruments and Test Instrument Sets
F2000
K2000 / K2010
F2000: Padded plastic carrying pouch with adjustable carrying strap.
The cover and carrying strap are equipped with snap fasteners.
• Device is secured with a variable support which is fastened with a Velcro strip for various dimensions from 20 to 38 cm.
• Side pocket dimensions: 3 cm deep x 20 cm high
• Fastened with Velcro, removable, elastic holders for 3 test probes
• Pouch dimensions: 38+4 cm wide x 31+3 cm high x 20+2 cm deep
K2000: aluminum case for PROFiTEST 0100S-II, PROFiTEST ONE and accessories
• Foam insert with adjustable compartments for test instrument and accessories
• Suitable for test sets PGS117T, 210, 211
• Case dimensions: 59 cm wide x 47.5 cm high x 12.5 cm deep
K2010: aluminum case for SECUTEST ..., SECUSTAR FM and accessories
• Foam insert with adjustable compartments for test instrument and accessories
• Case dimensions: 64.5 cm wide x 53.5 cm high x 16 cm deep
Z504J: aluminum case for PGS 2000
• Foam insert with adjustable compartments for test instrument and accessories
• Case dimensions: 47 cm wide x 37.8 cm high x 16.8 cm deep
Z504J
74
Type
Data Sheet No.
Article Number
F2000
3-349-126-02
Z700D
K2000
–
Z504K
K2010
–
Z504L
Z504J
–
Z504J
Made in Germany
Test Instrument Accessories – Overview
Suitable for use with following test instruments ➡
Type
Designation
PROFITEST 0100S-II
PROFITEST ONE
PROFi TEST C
PROFITEST 204
METRATESTER 5/5-F
METRATESTER 5-3P
SECUTEST S II
SECUTEST S lll
METRISO C
METRISO 500D
METRISO 1000D
METRISO 1000IR
METRISO 5000 D-PI
METRAOHM 413
METRISO 1000A
METRISO 5000A/AK
METRISO 5023
GEOHM C
GEOHM 33D
METRAtest 36 ASi
Overview of Accessories for Test Instruments
Modules, adapters, plugs, plug inserts, cable sets
SECUTEST PSI
PSI module (printer, memory, RS 232 interface)
DA-II
Printer adapter for external printer
✔
✔ ✔
✔
✔
✔ ✔
✔
✔ ✔
CEE Adapter
3-phase adapter for 3 x CEE
A3-16
5-pole 3-phase adapter for 16 A CEE outlets
✔ ✔ ✔
A3-32
5-pole 3-phase adapter for 32 A CEE outlets
✔ ✔ ✔
A3-63
5-pole 3-phase adapter for 63 A CEE outlets
✔ ✔ ✔
3-pole adapter
3-phase measuring adapter for all PROFiTEST C testers with earth contact plug
VL2
Test adapter for testing electrical devices and extension cables
Z500A
Variable plug adapter set, set of three, 3.5 to 12 mm diameter
✔ ✔ ✔ ✔
Telearm1
Telescoping rod for PE measurement
✔ ✔
✔ ✔ ✔ ✔
✔ ✔
TR25
Reel with 25 m measurement cable
✔ ✔
✔ ✔ ✔ ✔
✔ ✔
✔ ✔
TR50
Drum with 50 m measurement cable
✔ ✔
✔ ✔ ✔ ✔
✔ ✔
✔ ✔
SP350
Earth drill, 35 cm long
✔ ✔
Z580A
Crank generator
✔
✔ ✔ ✔ ✔
✔ ✔
✔
KY 5000A
Alligator clips, 2 ea.
✔
✔
Guard 5000A
Guard cable, 1 ea. with 1 alligator clip
✔
✔
Leadex 5000
Extension cable, 5 m
✔
✔
KS13
Cable set
KS17-2
Cable set
KS24
Extension cable, 4 m
PA4
Patient connector cables
✔
✔ ✔
✔
✔ ✔
✔ ✔ ✔ ✔
✔
✔
✔
✔ ✔
EL1
Adapter for testing extension cables
PRO-CH
Plug insert for using the EL1 adapter in Switzerland
✔ ✔
✔ ✔
PRO-GB
Plug insert for using the EL1 adapter in Great Britain
✔ ✔
✔ ✔
PRO-RSA
Plug insert for using the EL1 adapter in South Africa
✔ ✔
✔ ✔
SECU-cal 10
Calibration adapter for test instruments per DIN VDE 0701/0702 with test report
IrDa-USB
IR interface for connection to the USB port at a computer
✔ ✔ ✔
RS 232 – USB
Interface adapter cable from RS 232 at a test instrument to USB at a PC
✔ ✔
✔ ✔
✔
✔
✔
✔ ✔
✔
✔
Clip-on ammeters, temperature sensors
WZ12C
Clip-on current sensor, 1mA-10A~, 1mV/mA-1A-120A~, 1mV/A
✔ ✔
Z3409
Temperature sensor, Pt100, -40 ... + 600° C
✔ ✔
Probes
✔ ✔
SK2
Special cable with test probe, 2 m
SK5
Software for acoustic signaling including 5 m probe cable
Z745G
Brush probe
1081 probe
Triangular probe for floor measurements per EN 1081/DIN VDE 0100 T.610 ✔ ✔
✔ ✔ ✔ ✔
✔ ✔
✔
Barcode scanner / printer
✔
B3261
Barcode scanner
✔ ✔
✔
✔ ✔
Z721D
Barcode printer
✔ ✔
✔
✔ ✔
Z722D
Label set for barcode and label printer (W: 3 x 24 / 1 x 18 / 1 x 9 mm, L: 8 m each) ✔ ✔
✔
✔ ✔
Z722E
Label set for barcode and label printer (W: 5x18 mm, L: 8 m each)
✔ ✔
✔
✔ ✔
✔
✔
✔
Safety tester
AT3-IIS
AT3-IIS safety tester
✔ ✔
AT3-IIIE
AT3-IIIE safety tester
✔ ✔ ✔ ✔
F2000
Universal pouch
✔ ✔
K2000
Aluminum case for PROFi TEST 0100S-II and accessories
✔ ✔
Pouches, cases
K2010
✔
✔ ✔
✔
✔
✔ ✔
Carrying case for SECUTEST... and accessories
Consumable materials
PS-10P
Recording chart paper for PSI module, package of 10 rolls of 6 meters each ✔
✔
✔ ✔
Z3210
Printer ribbon cartridges for PSI module, package of 10
✔
✔
✔ ✔
Made in Germany
75
Software for Test Instruments
Support Software for Test Instruments – Overview
Software
METRATESTER
5-F
5-3P
PS3
PC.doc-WORD / -ACCESS
●
●
SECUTEST
PROFI TEST
SII
Slll
C
0100S-II
ONE
204
●
●
●
●
●
●
●
●
WinProfi
●
●
●
●
●
●
●
●
5000 D-PI
GEOHM
C
C
●
●
●
●
●
●
●
Remote 204
SECU-Up
●
●
ELEKTROmanager
●
●
PC.doc-WORD
PC.doc-ACCESS
METRISO
●
●
Report Software
Report Generation and Test Data Management
PC.doc-WORD: report software as a supplement to Microsoft Word
PC.doc-WORD inserts test results and data entered at the test instrument input module into test or list forms. These can
then be supplemented and printed out with Word.
• For SECUTEST SII, SIII, METRATESTER 5-F, PROFITEST 0100S-II, PROFITEST C and METRISO C test instruments
• For Windows 95, 98, 2000, XP and Word 97, 2000, XP
PC.doc-ACCESS: report generating and test data management software as a supplement to Microsoft Office
PC.doc-ACCESS manages device, machine, equipment, master and test data. Available test instrument data are
automatically entered to master data and test data lists which are assigned to individual customers. Data are represented
in accordance with the respective test regulation. Data are displayed as lists or in data sheet format, and can be sorted
and filtered in a variety of different ways. Complete test data management is thus made possible. Reports and deadline
lists can be printed out for selectable ID number ranges.
• For SECUTEST SII, SIII, METRATESTER 5-F, PROFITEST 0100S-II, PROFITEST C and METRISO C test instruments
• For Windows 95, 98, 2000, XP and Access 2000, XP
➲ See page 91 for training seminar: GTT1226
SK5
Type
Data Sheet No.
Article Number
PC.doc-WORD
–
Z714A
PC.doc-ACCESS
–
Z714B
PC.doc-upgrade
–
Z714C
PC.base-upgrade
–
Z714D
Remote Control for SECUTEST Test Instruments
Upgrade program for enabling the “remote control” feature
• A function for “automatic recognition of measuring point change” is added to the protective conductor
measurement.
• During protective conductor measurement, the test instrument recognizes whether or not the test probe is in contact
with the protective conductor, which is indicated by means of two different acoustic signals.
• This function is very useful where several protective conductor connections need to be tested.
SECU-Up
Type
Data Sheet No.
Article Number
SK5
–
Z745K
Software Upgrade for Older Series SII and SIII Instruments
Software upgrade to new standards DIN VDE 0701-1:2000-09 and DIN VDE 0751-1:2000-10for older series
SII and SIII devices (prerequisite: article no. M7xxx)
76
Type
Data Sheet No.
Article Number
SECU-Up
–
Z713C
Made in Germany
Software for Test Instruments
PS⏐3
Modular, Universal Software for Test Instruments –
Systems, Equipment and Service Management, Plus Report Generation
Automatic read-in and analysis of measured values from testing conducted on systems and equipment. Systems
and equipment management with respective test results stored to a database. Automatic generation of test
reports in accordance with recommendations issued by the trade associations.
PS3 Compact
Report generation and test data management for electrical devices and equipment with SECUTEST...,
PROFi TEST 0100S-II, PROFITEST C and METRISO C
PS3 GM:
Basic module and device driver, allows for the read-out of measured values from PROFi TEST 0100S-II, PROFiTEST C,
METRISO C, PROFiTEST 204 and SECUTEST... test instruments (all variants).
PS3 AM:
PS3 AM (device driver, basic module and add-on module) for expansion with the following modules:
• Equipment management
• Remote
• Maintenance management
• Barcode printing
PS3 add-on modules:
• PS3 Navigator − LHNavigator and LHViewer (prerequisite: PS3 AM)
• PS3 Client − client options (prerequisite: PS3 AM)
• PS3 Hazard Analysis − hazard analysis (prerequisite: PS3 AM)
PS3 update:
• Update to PS3 AM, version 9, including hazard analysis, –
Basic software: PS3 add-on module (version 3 or 4)
PS3 upgrade:
Upgrade to PS3 AM including hazard analysis
• Basic software: SE-Q.base
• Basic software: PC.base
• Basic software: PS3 compact (any version)
• Basic software: PS3 basic module (any version)
Maintenance contracts:
PS3 maintenance contract upon request
➲ See page 91 for training seminar: GTT1224A ... G
Type
Winprofi
Data Sheet No.
Article Number
PS3 Compact
–
Z530K
PS3 GM
–
Z530E
PS3 AM
–
Z531N
PS3 Navigator
–
Z531C
PS3 Client
–
Z531D
PS3 Hazard Analysis
–
Z531M
PS3 Update
–
Z530S
PS3 Upgrade
–
Z530T
PS3 Maintenance Contract
–
Z530X
Software for Communication Between the Test Instrument and the PC
This software is used to update the following test instruments:
PROFITEST 0100SII, PROFITEST C, METRISO C, GEOHM C, PROFITEST 204 and METRAtest 36ASi.
The software is freeware and runs under Windows 95, 98, NT4 and 2000.
It provides the following functions:
• Update test instrument firmware
• Download measured values
• Upload test reports
• Generate simple reports
• Can be installed free of charge from any PS3 CD ROM.
Made in Germany
77
Software for Test Instruments
ELEKTROmanager
Software for Measurement and Documentation of Electrical Devices and
Electrical Installations
Software for execution and analysis of tests in accordance with German occupational safety law (BetrSichV)1,
BGV A3 (previously VBG 4), DIN VDE 0100-T610, DIN VDE 0105, DIN VDE 0701, DIN VDE 0702 and DIN VDE 0113
ELEKTROmanager represents a new software generation for data logging and data management, as well as for controlling
test sequences used by electricians concerned with effectiveness, technical competence and legal security. Use of
ELEKTROmanager is easy to learn and self-explanatory to a great extent.
All common measuring instruments supplied by many manufacturers can be read out, and many can even be controlled
with ELEKTROmanager.
• The software automatically controls measurement or calibration, and generates a complete test report.
• All test regulations can be freely edited.
• Windows user interface
• Any measuring instrument can be incorporated with the help of a device driver (add-in).
• Different measuring instruments can be used concurrently for measurement of a terminal device or a production
sequence.
• Simultaneous inventory management saves additional expense.
• Test reports can be individualized (e.g. with company logo).
• The software is capable of recognizing devices which have already been measured (transponder technology).
• The entire instrument inventory becomes transparent providing an exact overview of all utilized devices and test
reports, their current status, as well as maintenance and repair costs.
• Unrestricted network compatibility
• Measuring instruments can be controlled with PDAs using PalmOS. Measurements are started at the PDA, and
measurement results are uploaded automatically from the measuring instruments and subsequently transferred to
the ELEKTROmanager.
➲ See page 91 for training seminar: GTT1227A, GTT1227B
Type
ELEKTROmanager 4.0
Article Number
Z610A
Add-in software for reading out device memory from the following test instruments
Device driver for PROFITEST 204 and MetraMachine 204/439
Z610C
Device driver for PROFITEST 0100-SII (via PSI module)
Z610E
Device driver for Secutest SII / SIII (via SECUTEST PSI)
Z610I
Add-in software for direct read-out and remote control of the following test instruments
(without installed PSI module) from the PC
Device driver for SECUTEST 0701/0702 SII, SECUTEST 0751/601 P/S
Z610K
Device driver for SECUTEST SII
Z610M
Device driver for SECUTEST SIII
Z610N
Bed testing regulations
Z610P
GEPI 1.0 − hazard analysis / ascertainment of test intervals
Z610Q
eTROLL software for communication between PDA/RDA and the test instrument
Z610O
ELEKTROmanager 4.5
Z610R
Add-in software for reading out device memory from the following test instruments
Device driver for PROFITEST 204 and MetraMachine 204/439
Z610G
Device driver for PROFITEST 0100-SII (via PSI module)
Z610T
Device driver for Secutest SII / SIII (via SECUTEST PSI)
Z610U
Add-in software for direct read-out and remote control of the following test instruments
(without installed PSI module) from the PC
Device driver for SECUTEST 0701/0702 SII, SECUTEST 0751/601 P/S
Z610V
Device driver for SECUTEST SII
Z610W
Device driver for SECUTEST SIII
Z610X
Bed testing regulations
Z611I
GEPI 2.0 − hazard analysis / ascertainment of test intervals
Z610Z
eTROLL software for communication between PDA/RDA and the test instrument
Z610Y
ELEKTROmanager upgrade from 4.0 to 4.5, including 2 add-ins
Z611H
ASCII import 4.5
Z611K
Palm OS handhelds and accessories
MEAZURA RDA laser barcode scanner, serial connection
78
Z611A
MEAZURA RDA RFID 125 kHz (transponder), serial connection
Z611F
MEAZURA RDA, serial connection
Z610H
MEAZURA serial connector cable
Z611C
MEAZURA charging and transmission station, USB connection
Z611B
Adapter cable / adapter, specially designed for connecting PDA to device
Z611D
Made in Germany
Workshop Test Panels – VDE 0104
METRATESTER®5-3P
Workshop Test Panel for Testing Devices in Accordance with
DIN VDE 0701/0702, DIN VDE 0104
The METRATESTER 5-3P test panel can be used as a portable or a stationary device for the measurement and
testing of electrical devices after repair or modification in accordance with DIN VDE 0701, as well as for periodic
testing per DIN VDE 0702. According to these regulations, protective conductor resistance, insulation resistance,
differential current, equivalent leakage current and, for data processing systems and office machinery, absence
of voltage at exposed parts accessible to the user must be measured.
Measurement of operating voltage and current at the DUT, as well as testing of extension cables for conductor
continuity and polarity reversal represent further applications for the substantiation of correct functioning of
electrical equipment. The VL2 test adapter allows for quick, safe testing of extension cables. The protective
conductor at the mains connection can also be tested for the absence of voltage, and line voltage can be
measured. Protective conductor measurement is performed correctly in accordance with DIN VDE 0104.
• Dimensions: 380 x 300 x 220 mm (with lid)
• Weight: approx. 8 kg
See page 55 for further details and accessories.
SECUTEST ® 21F
Type
Data Sheet No.
Article Number
METRATESTER 5-3P
–
M700S
VL2 test adapter
3-349-241-03
Z600B
Workshop Test Panel for Testing Devices in Accordance with DIN VDE 0701/0702
The SECUTEST 21F test panel has been designed for the set-up of test stations at shops specialized in electrical
work. It is used for measurement and testing of electrical devices after repair or modification in accordance with
DIN VDE 0701, as well as for periodic testing per DIN VDE 0702.
The test panel is designed for wall mounting. It is equipped with a mains switch with undervoltage trigger and
lock. Load currents of up to 25 A and line voltages of up to 500 V can be measured. Compliance with
DIN VDE 0104 also assures flawless protective conductor measurements.
• Dimensions: 532 x 792 x 179 mm
• Weight: approx. 24 kg
Type
Data Sheet No.
Article Number
SECUTEST 21F
–
M601A
Technical Data, METRATESTER 5-3P, 21F
Measured Quantity
Line voltage
Device Protective
Conductor Resistance
Insulation
Resistance
Equivalent
Leakage Current
Absence of Voltage
207 ... 253 V∼
0 ... 19.99 Ω
0 ... 19.99 MΩ
0 ... 19.99 mA
1V
10 mΩ
1 kΩ, 10 kΩ
10 mA
1 μA
Open-circuit voltage
–
Approx. 20 V
28 V∼
–
Internal resistance
–
–
Approx. 100 kΩ
Measuring range
Resolution
600 V
0 ... 1.999 mA
2 kΩ
Load Current via
Mains Outlet
0 ... 16.00 A∼
10 mA
–
–
Short-circuit current
–
–
< 10 mA
< 20 mA
–
–
Nominal current
–
210 mA const.
–
–
–
–
± (1.5% rdg. + 1 d)
± (2.5% rdg. + 2 d)
Max. error at reference conditions
± (2.5% rdg. + 2 d) as of 10 d
In accordance with the guidelines for
“workshop equipment for electrical installation operations”
issued by the ZVEH / VDEW
Made in Germany
79
Clip-On Meters
METRACLIP ® 50 ... 71
Clip-On Meters with Analog or Digital Display for Service Technicians
Current within conductors can be conveniently measured with clip-on meters. The following advantages result:
• The electrical circuit need not be interrupted, no electrical connection to the conductor.
• Measurement of current up to 3000 A, electrical safety per IEC 61010
METRACLIP 50/51:measured value memory with mechanically (METRACLIP 50) or electrically arrested pointer (METRACLIP 51)
METRACLIP 60: 3¾-place digital display, automatic measuring range selection, data HOLD and Max-Min display
METRACLIP 61: 4½-place digital display, automatic or manual measuring range selection, data HOLD and Max-Min display
METRACLIP 70: 4½-place digital display, automatic or manual measuring range selection, data HOLD and Max-Min display
METRACLIP 71: three 4½-place digital displays with background illumination, data HOLD and Max-Min display
Feature
Clip opening
Measuring category Vmax
Display
Resolution
Type
Data Sheet No.
Article Number
METRACLIP 50
3-349-049-03
M300A
METRACLIP 51
3-349-049-03
M300B
METRACLIP 60
3-348-983-03
M311C
METRACLIP 61
3-348-983-03
M311D
METRACLIP 70
3-349-064-03
M312A
METRACLIP 71
3-349-061-03
M312B
METRACLIP 50
28/30x20 mm dia.
III/600V, IV/300V
Analog
METRACLIP 51
60/70x30 mm dia.
III/1 kV, IV/600 V
Analog
1.5 ... 300 A/ac
Voltage
Frequency range for U/I
Current
Memory
Frequency measurement
Harmonic analysis
Continuity / buzzer
Resistance
Phase sequence
Active power
Apparent power
Reactive power
Power factor
Energy
Sampling rate
Interface
15 A...3000 A/AC
METRACLIP 60
max. 24 mm dia.
III
Digital
0.01/0.1 A
400 A/ac
METRACLIP 61
40 mm dia.
III/300 V, II/600 V
Digital
0.01 mA/0.01 A
0...300 A/ac (4 ranges)
150 V ... 600 Vac
150 V ... 600 Vac
600 V/AC
–
48...52/40...100/
40...400 Hz
–
–
–
–
–
40...60/40...100/
40...400 Hz
HOLD function
–
–
–
–
I: 50...60 Hz
U: 50...400 Hz
Min-Max
–
–
●
400...4000 Ω
50...60 Hz
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2.5/sec.
–
DATA HOLD
–
–
–
–
–
–
–
–
–
2/sec. (bar graph: 12/sec.)
METRACLIP 70
METRACLIP 71
42/25x25/50x5 mm dia.
50/80x5 mm dia.
III/600 V
III / 600 V
Digital (4000 digits)
Triple (3x10,000 pixels)
4½ place
4½ place
0.2...400...1000 A RMS/ac,
1500 Ass AC
0.2...400...1400 A/dc
0.4...600V/dc/ac
1500 Vss DC
45...450 Hz
10 Hz ... 5 kHz
Min/-Max 500 ms
Min/Max 30 Hz
3 ranges: 100 Hz...4 kHz
0.5 Hz...20 kHz
–
Harmonic dist.: CF, THD, DF
Ω / diode (acoustic)
–
5 ranges: 0.5 Ω ... 4 MΩ
–
–
–
–
–
–
(2.5/sec.)
–
10 W...600 kW
10 VA...600 kVA
10 var...600 kvar
0 ... 1
–
4 kHz
–
30/300 mA:±2% rdg.
1% (typ.)
U=1% / I/P=2% (typ.)
±5 d
30/300A:-3/-5 rdg.±5 d
Power Supply
–
3 V, 850 mAh
2 ea. IEC 6 LR03 (AAA micro)
2 x LR44/SR44
9 V, IEC 6 LR61
4 x IEC LR6 (AA mignon)
Dimensions / weight with battery(ies) 88 x220x40 mm / 0.5 kg 112 x313x60 mm / 0.9 kg 69 x191x33 mm / 0.22 kg 64 x176x23 mm/0.125 kg 97 x254x46 mm/0.6 kg 103x275x50 mm/0.67 kg
Accuracy
80
Class 2.5
Class 2.5
I:±(2%+7 d) U:±(1%+5 d)
Made in Germany
Clip-On Meters
METRACLIP ®72 ... 81
Clip-On Meters with Analog or Digital Display for Service Technicians
METRACLIP 72 Power: handy, digital, RMS clip-on meter to 400 A AC-DC, power, voltage, resistance, continuity and much more, in pouch with accessories
METRACLIP 73: universal, digital clip-on power meter for up to 200 A AC / 300 A DC, voltage (TRMS), energy, resistance, continuity and much more, in case with accessories
METRACLIP 74: universal, digital clip-on power meter for up to 2000 A AC-DC, voltage (TRMS), energy, resistance, continuity and much more, in case with accessories
METRACLIP 75 Automotive: handy, digital, RMS clip-on meter to 400 A AC-DC, temperature, voltage, resistance, continuity and much more, in pouch with accessories
METRACLIP 80: bar graph and digital display, Max-Min and mean value memory, digital interface for PC, integrated 3-phase adapter
METRACLIP 81: matrix display for numeric and oscilloscope read-outs, 8 display pages can be saved to memory, Min-Max and mean value memory,
data storage for 5 parameters over a period of 24 hours
METRACLIP 72 Power
< 26 mm dia.
III/600 V
Digital
4000 digits
0.2...400 A dc/ac RMS
0.2...600 V dc/ac RMS
...1 kHz
Min-Max + HOLD only
10...19.99 kHz
–
1 - 40 Ω
0.2 - 40 kΩ (3 ranges)
2-wire at 50/60 Hz
5 W to 240 kW
–
–
0.2 ... 1.0
–
–
–
typically 1% + 2 d
Type
Data Sheet No.
Article Number
METRACLIP 72 Power
3-349-250-03
M312E
METRACLIP 73
3-349-253-03
M312F
METRACLIP 74
3-349-253-03
M312G
METRACLIP 75 Automotive
3-349-250-03
M312H
METRACLIP 80
3-349-054-03
M312C
METRACLIP 81
3-349-065-03
M312D
METRACLIP 73
METRACLIP 74
METRACLIP 75 Automotive
METRACLIP 80
40/7x52 mm dia.
65/22x64 mm dia.
< 26 mm dia.
55 mm dia.
IV/600 V
IV / 600 V
III / 600 V
III / 600 V
Digital (double)
Digital (double)
Digital
digital+bar graph
3000 digits
3000 digits
4000 digits
4½ place
0.1...200Aac/ac+dcTRMS 1...2000Aac/ac+dc TRMS
0.2...400 A dc/ac RMS 400/1000 A/dc/ac TRMS
...300Adc
...2000Adc
...1000Vdc
...1000Vdc
0.2...600 V dc/ac RMS
400/600 V dc/ac TRMS
...750Vac/ac+dcTRMS
...750Vac/ac+dcTRMS
...1 kHz
20 Hz...1 kHz
...2 kHz
–
< 30 Ω
... 2000 Ω
yes
... 200 kW
... 200 kVA
... 200 kVar
0 ... 1
... 2000 kWh
2/s
–
–
...2 kHz
–
< 30 Ω
... 2000 Ω
yes
... 2000 kW
... 2000 kVA
... 2000 kVar
0 ... 1
... 2000 kWh
2/s
–
–
Min-Max + HOLD only
–
–
1 - 40 Ω
0.2 - 40 kΩ (2 ranges)
–
–
–
–
–
–
–
–
typically 1% + 2 d
9 V, IEC 6 LF22
9 V, IEC 6 LF22
9 V, IEC 6 LF22)
9 V, IEC 6 LF22
70 x193x37 mm/0.26 kg 90 x270x50 mm/0.55 kg 90x285x50 mm/0.61 kg 70 x193x37 mm/0.26 kg
Made in Germany
METRACLIP 81
60 mm dia.
IV / 600 V
multimeter+oscilloscope
Dot matrix: 160 x 128 pixels
40/400/2000A/dc/acTRMS
Feature
Clip opening
Measuring category Vmax
Display
Resolution
4/40/400/600V/dc/acTRMS
Voltage
Current
10 Hz...1 kHz
Frequency range for U/I
Min-Max
20.0 Hz...1 kHz
–
–
–
Min-Max / mean value / logger
10.0 Hz...1 kHz
Harmonic dist.: CF, THD, DE
–
–
10 W...600 kW
10 VA...600 kVA
10 var...600 kvar
0.3 cap. ... 1 ... 0.3 ind.
via PC
9 kHz
–
1% ... 2.5% rdg. ±5 d
4/40/400/1200 kW/VA dc
4/40/400/1200 kW/VA dc
0 ... 850 kvar
0.3 cap. ... 1 ... 0.3 ind.
●
9 kHz
special RS232
1% ... 3% rdg. ±5 digits
Memory
Frequency measurement
Harmonic analysis
Continuity / buzzer
Resistance
Phase sequence
Active power
Apparent power
Reactive power
Power factor
Energy
Sampling rate
Interface
Accuracy
9 V, IEC 6 LR61
98 x251x52 mm/0.5 kg
6 ea. IEC LR6
Power supply
98x300x52 mm/0.82 kg Dimensions / weight with battery(ies)
81
Voltage Testers, Cable Detection System
Voltages Testers
2-Pole Voltage Meters and Multiple Measuring Instruments with Analog or Digital Display
These 2-pole voltage meters and multiple measuring instruments fulfill requirements for voltage testers
per DIN EN 61243-3 / VDE 682, part 401 (previously: DIN VDE 0680, part 5).
• Easy to operate, VDE GS approved
• Measuring category III and IV devices, double indication reliability with LEDs
ProfiSafe 1
ProfiSafe 1
This voltage, phase, continuity and polarity tester plus phase sequence indicator has been equipped with a long-life, rechargeable
lithium battery for the display of continuity and phase test results. The battery is continuously recharged with a high performance
solar cell, even with minimum ambient light. This maintenance-free voltage source assures long service life and reliable operation.
• 9 LEDs for the display of voltage, continuity, phase and direction of rotation
• Phase testing, display of direction of rotation and continuity testing
• Rugged housing, hazard-free use even under damp conditions, IP 65 protection
METRAVOLT 7A
METRAVOLT7A
• The MetraVolt 7A is a 2-pole voltage tester with LCD indicator, high quality moving-iron measuring element and LED display.
Direct and alternating current can be tested, and polarity and phase sequence can be determined within the nominal voltage
range. The measuring movement is protected against impacts, water and dust by the unbreakable rubber housing. Thanks
to IP 65 protection, the MetraVolt 7A can also be used in the rain, and is already in compliance with the new EN 61243-3
standard (VDE 0682, part 410).
METRAVOLT12D
• Fully automated measuring sequence, self-test, measurement value storage, battery saving circuit
• Rugged housing, hazard-free use even under damp conditions, IP 65 protection
• Intrinsic error: 0.5% of rdg. + 1 digit
METRAVOLT 12D
Feature
ProfiSafe 1
Complies with DIN VDE 0680
Voltage
Dielectric strength
Test voltage
Phase testing
Phase sequence indicator
Resistance
Continuity test
Frequency range
Power supply
Battery test
Dimensions
Weight
CAT IV.
CableCop 300
METRAVOLT 7A
METRAVOLT 12D
●
●
●
12 ... 690 V
> 5 kV (1.2 / 50 µs pulse wave)
5 kV
24 ... 740 V
12 kV (surge voltage)
6 kV
0 ... 1200 V TRMS
>10 kV (1.2/50 µs pulse wave)
5 kV
●
●
●
●
●
●
–
–
–
0 ... 100 Hz
–
–
75 x 274 x 47 mm
0.46 kg
0 ... 1999 kΩ
●
0 ... 2000 Hz
Lithium battery + solar cell
–
50 x 230 x 35 mm + 1 m cable
0.17 kg
Type
Data Sheet No.
ProfiSafe 1
–
M630B
METRAVOLT 7A
–
M630D
METRAVOLT 12D
3-349-201-03
M630C
●
15 ... 10,000 Hz
9 V flat cell battery, IEC 6F 22
●
60 x 240 x 40 mm
0.29 kg (with battery)
Article Number
Cable Detection System for Current and Voltage-Free Cables, and Current and Voltage
Conducting Cables
Current and voltage-free, as well as current and voltage conducting cables in electrical circuits with up to 300 V can be
pinpointed with the cable detection system. Cables and conductors, electrical circuits, short-circuits and earth faults
can be located, and protective conduits and coaxial cable can be traced as well without interrupting power or shutting
down sensitive electronic components. Detection is possible in walls and concrete, as well as underground.
.
voltage range
9 ... 300 V
Measuring frequency
32,768 kHz
Display / signal
LED / buzzer
Typical applications
Location of cables, switches, short-circuits and earth faults,
tracing of protective conduits and coaxial cables
Range of applications
Walls, ground, concrete
Included
Case with T320 transmitter, S330 signal generator, R300 receiver, two 9 V batteries,
2 measurement cables, 2 alligator clips, 2 test probes, operating instructions
Dimensions / weight
.
82
310 x 200 x 85 mm / case and contents: approx. 1.95 kg
Type
Data Sheet No.
Article Number
CableCop 300
–
GTM5292000R0001
Made in Germany
The New IEC 61010-1 Safety Standard
Measuring Categories
The following measuring categories have been established in accordance with the IEC 61010 standard.
CAT I
Measurements in electrical circuits which are not directly connected
e.g. batteries etc.
to the mains
CAT II
Measurements in electrical circuits which are electrically connected by means of a plug, e.g. at home, in the
to the low-voltage mains
office or laboratory etc.
CAT III
Measurements in building installations
stationary consumers, distributor
terminals, devices connected permanently
to the distributor
CAT
IV.
Measurements at power sources for low-voltage installations
meters, mains terminals, primary
overvoltage protection
In the case of multimeters and test instruments, the CE declaration of conformity confirms that European regulations (low-voltage
directive and EMC directive) are adhered to. This declaration is a prerequisite for putting products into circulation within the European
Community. Adherence is substantiated by fulfilling the following standards: IEC 61010-1 (international), EN 61010-1(German version)
and VDE classification VDE 0411-1. Safety requirements for electrical equipment for measurement, control and laboratory use are
described in this standard. The IEC standard was first issued in 1990. After various amendments and addendums (A1 1992, A2 1995),
the most recent revision (the so-called second edition) issued in 2001 has come into force. This revision level has been adopted into the
second issue of the German version: EN 61010-1. The currently valid revision level is 8/2002.
Made in Germany
83
Power Supply Overview
Laboratory
Power Supplies
1
Series SL 32 EL
32 EL 150 R 30
32 EL 300 R 30
84
Query meas. values
Sequence control
0.4 + 35
0.5 + 20
0.5 + 10
0.5 + 70
0.5 + 45
0.5 + 25
0.5 + 70
10
10
10
15
15
15
30
25
20
10
50
25
20
50
●
●
●
●
●
●
●
●
●
●
●
●
●
●
❍
❍
❍
❍
❍
❍
❍
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0...52
0...80
0...52
0...80
0...52
0...80
0...52
0...80
0...25
0...12.5
0...50
0...25
0...100
0...50
0...150
0...75
0.1 + 17 0.2 + 25
0.1 + 20 0.2 + 15
0.1 + 17 0.2 + 50
0.1 + 20 0.2 + 25
0.1 + 17 0.25 + 100
0.1 + 20 0.25 + 50
0.1 + 17 0.3 + 150
0.1 + 20 0.3 + 80
10
10
10
15
10
15
10
15
15
15
25
20
80
30
120
60
●
●
●
●
●
●
●
●
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
❍
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
–
●
●
●
●
●
●
●
●
–
–
–
–
–
–
–
–
–
–
–
–
●
●
●
●
●
●
●
●
●
●
●
●
–
–
–
–
–
–
0.15 + 30
0.15 + 40
0.15 + 80
0.15 + 40
0.15 + 45
0.15 + 80
0.15 + 50
Total System
Error
1
3
3
1
1
3
–
–
–
–
–
–
3
3
2
3
2
2
Residual ripple
Voltage
V
Current
A
Voltage
mV
Current
mA
Voltage
mVeff
Current
mAeff
0...20
0...40
0...80
0...20
0...40
0...80
0...32
0...10
0...6
0...3
0...20
0...12
0...6
0...18
20
15
15
30
23
23
40
28
15
15
38
38
20
50
10
10
10
15
15
15
30
25
20
10
50
25
20
50
0...25/25/7
0...1/1/5
Output
Voltage
Output
Current
V
A
0 ... 18
0 ... 6
0 ... 36
0 ... 3
0 ... 65
0 ... 1.5
15/15/17
7/7/12 0.5/0.5/0.5
Setting Resolution
Voltage
Current
mV at V
mA
1 at 0 ... 3.999
5 at 4 ...18
1 at 0 ... 3.999
10 at 4 ... 36
1 at 0 ... 3.999
20 at 4... 65
0.5/0.5/2
Mains Correction,
Voltage
Current
% + mV
% + mA
≤ 1
0.01 + 3 0.02 + 8
0.02 + 10
0.01 + 3 0.02 + 8
0.02 + 10
0.01 + 3 0.02 + 8
0.02 + 10
≤ 1
≤ 1
Load Input
Input Power
Current
Voltage
Front Panel
Max. W
Max. A dc
1
1
150
300
0...30
0...30
Overvoltage
protection
Auto-ranging
output
Output
Rear panel
0...10
0...6
0...3
0...20
0...12
0...6
0...18
Current
±
(% +mA)
Front panel
(200)
(240)
(240)
(320)
(360)
(360)
(430)
25 + 25 +
35
32 K 65 R 1.5
0...20
0...40
0...80
0...20
0...40
0...80
0...32
Voltage
±
(% +mV)
Setting Range
Continuous Intermittent
1
Current
A
0...7
0...± 7 0.05 + 4
0.1 + 4
0...30
0...± 4 0.05 + 16
0.1 + 2
0...80 0...± 1.5 0.05 + 40
0.1 + 1
2x0...8 2x0...± 3 0.05 + 4
0.1 + 2
2x0...16 2x0...± 1.5 0.05 + 8
0.1 + 1
2x0...40 2x0...± 0.6 0.05 + 20 0.1 + 0.5
Power
Max. W
32 K 36 R 3
Output On/Off
49
120
120
2x24
2x24
2x24
1
Sink mode
500
500
1000
1000
2000
2000
3000
3000
Series LSP 32 K
32 K 18 R 5
Electronic
Loads
Voltage
V
●
●
–
●
●
–
●
●
●
●
●
●
●
●
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
dyn.
–
–
–
–
–
–
–
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
●
●
–
––●
–
–
l
–
Overvoltage
protection
Auto-ranging
output
(200)
(240)
(240)
(320)
(360)
(360)
(430)
Output,
Front Panel
IEEE 488
120
120
120
240
240
240
320
120
120
120
240
240
240
320
Current
mARMS
RS 232
Intermittent
Interfaces
Output On/Off
Series SLP 32 N
32 N 20 R 10
32 N 40 R 6
32 N 80 R 3
32 N 20 R 20
32 N 40 R 12
32 N 80 R 6
32 N 32 R 18
Series LSP 33 K
33 K 7 EU 5/2x25 R 1 D
Continuous
Residual Ripple
Sink mode
Analog Controlled
Laboratory
Power Supplies
Voltage
mVRMS
Setting Range
Via basic instrume
Series SSP 32 N
32 N 20 RU 10 P
32 N 40 RU 6 P
32 N 80 RU 3 P
32 N 20 RU 20 P
32 N 40 RU 12 P
32 N 80 RU 6 P
32 N 32 RU 18 P
Series SSP 62 N/64 N
62 N 52 RU 25 P
62 N 80 RU 12.5 P
62 N 52 RU 50 P
62 N 80 RU 25 P
64 N 52 RU 100 P
64 N 80 RU 50 P
64 N 52 RU 150 P
64 N 80 RU 75 P
Series MSP 64 D
Basic unit 64 D 42 P
MSP control module
ES 31 K 7 R 7 P plug-in module
ES 32 K 30 R 4 P plug-in module
ES 32 K 80 R 1.5 P plug-in module
ES 31 K 2x8 R 3 P plug-in module
ES 31 K 2x16 R 1.5 P plug-in module
ES 31 K 2x40 R 0.6 P plug-in module
Setting
Accuracy
Analog
Power
Max. W
SELV safety
extra-low voltage
Analog
interface
Computer Controlled
Laboratory
Power Supplies
Load Correction
Voltage
Current
% + mV
% + mA
Ripple Mains Input
Vac
mVRMS 50/60 Hz
0.02 + 10
0.02 + 8
<2
115/230
0.02 + 10
0.02 + 8
<2
115/230
0.02 + 10
0.02 + 8
<2
115/230
Max. Vdc
Resolution,
Current Sink
mA
Resolution,
R-Load Curve
μW
Mains Input
Vac
50/60 Hz
350
350
10
10
10
10
115/230
115/230
Made in Germany
Computer Controlled Laboratory Power Supplies
SSP KONSTANTER 32 N
Computer Controlled Laboratory Power Supplies: Series SSP 120 … 320
SSP KONSTANTER 120, 240 and 320 (single output system power supply) are single output computer
controlled laboratory power supplies for universal use in R&D, production and testing.
Our innovative BET circuit technology (bidirectional energy transformation) allows for practically load
independent response times < 1 ms (< 4 ms with 80 V device). The analog interface includes monitor,
auxiliary power and programmable signal outputs, as well as trigger and setpoint inputs.
• Diverse functionality, extensive calibration report, minimal power loss
• Auto-ranging output with 120 W, 240 W or 320 W
• Output: voltage and current regulated, increased output power for brief intermittent periods
• Very short response times thanks to BET technology, typically 1 ms
• Dynamic sink operation, excellent dynamic control parameters
• Minimal residual ripple, output On/Off function, lockable control panel
• Master-slave operation for parallel and series connection
• Sequence controls for the generation of voltage and current sequences
• Overvoltage, overcurrent and excessive temperature protection, calibration procedure for menu-driven
balancing
• RS 232 interface (complete device operation) / analog interface
• Floating output terminals at front and rear, can be electrically and mechanically combined into multi-channel units
• Dimensions: bench-top instrument (W x H x D) 221.5 x 102 x 397.5 mm, for 19" rack: ½19" x 2 standard
height units x 400 mm
• Weight: approx. 2.8 kg
Optional:
• IEEE 488 interface (listener/talker for configuration and querying measured values)
• Driver software for LabView, LabWindows CVI and HPVEE
● Optional accessories: mounting accessories for 19" racks (see table on page 89)
Type
120 W
240 W
320 W
SSP KONSTANTER 62/64 N
Data Sheet No.
Article Number
32 N 20 RU 10 P
3-348-843-03
K320A
32 N 40 RU 6 P
3-348-843-03
K321A
32 N 80 RU 3 P
3-348-843-03
K322A
32 N 20 RU 20 P
3-348-843-03
K330A
32 N 40 RU 12 P
3-348-843-03
K331A
32 N 80 RU 6 P
3-348-843-03
K332A
32 N 32 RU 18 P
3-348-843-03
K334A
IEEE 488 interface
3-348-843-03
K380A
Computer Controlled Laboratory Power Supplies: Series SSP 500 … 3000
SSP KONSTANTER 500, 1000, 2000 and 3000 devices (single output system power supply) are single
output computer controlled laboratory power supplies for universal use in R&D, production and testing.
Special circuitry allows for jumping from 0 V to nominal voltage (and back again) under nominal load
conditions within response times of less than 10 ms. The analog interface includes monitor and
auxiliary power outputs, as well as programmable trigger and setpoint inputs.
• Diverse functionality, minimal power loss
• Auto-ranging output with 500 W, 1000 W, 2000 W or 3000 W
• Output: voltage and current regulated, increased output power for brief intermittent periods
• Short response times thanks to special circuitry, typically 10 ms
• Dynamic sink operation, excellent dynamic control parameters
• Minimal residual ripple, output On/Off function, lockable control panel
• Sequence controls for the generation of voltage and current sequences
• Master-slave operation for parallel /series connection, overvoltage, overcurrent and excessive temp. protection
• Analog interface, output terminals at rear panel
• Dimensions: benchtop device (W x H x D) 465 x101 / 190 x 500 mm, for 19" rack: 19"x2/4 standard
height units x 500 mm
• Approx. weight: 62N/500 W: 12 kg, 62N/1000 W: 13 kg, 64N/2000 W: 22 kg, 64N/3000 W: 28 kg
Optional:
• RS 232 and IEEE 488 interfaces (listener/talker for configuration and querying measured values)
• Driver software for LabView, LabWindows CVI and HPVEE, calibration report upon request
● For optional accessories refer to the table on page 89.
500 W
1 kW
2 kW
3 kW
Made in Germany
Type
Data Sheet No.
Article Number
62 N 52 RU 25 P
3-349-078-03
K344A
62 N 80 RU 12.5 P
3-349-078-03
K341A
62 N 52 RU 50 P
3-349-078-03
K345A
62 N 80 RU 25 P
3-349-078-03
K343A
64 N 52 RU 100 P
3-349-078-03
K352A
64 N 80 RU 50 P
3-349-078-03
K351A
64 N 52 RU 150 P
3-349-078-03
K362A
64 N 80 RU 75 P
3-349-078-03
K361A
IEEE488/RS 232 interface
3-349-078-03
K382A
RS232 interface
3-349-078-03
K383A
85
Computer Controlled Laboratory Power Supplies, Soft Front-Panel
GM SSP-SFP
Soft Front-Panel PC User Interface for SSP Konstanters
Virtual instruments: KONSTANTER with soft front-panel
➀
Soft front-panel
Standard software platform,
device drivers for
LabWindows – LabView – HPVEE
➀
➁
➁
➂
Loads,
DUTs
All SSP Konstanter functions are controlled and displayed at a PC with this software.
• Free download
• For serial as well as IEEE interface
• Runs under Windows 95, 98, NT4 and 2000
Prerequisite: NI-VISA driver or additional NI-488.2 driver for control via GPIB must be installed
• Target groups: R&D, production, test equipment fabrication, system manufacturers
➀ Integrated software included in our KONSTANTERs simplifies use and allows for the generation of automated
sequences.
➁ Intuitive user interface and device drivers for standard software quickly place all of the functional options of
KONSTANTER instruments at the disposal of the user, and dramatically shorten learning curves.
➂
MSP KONSTANTER 64 D
➂ As device-specific software, our soft front-panel provides users with the advantages offered by “virtual
instruments” without the need for a complex standard platform.
Computer Controlled Laboratory Power Supplies, Multiple Outputs: MSP Series
The MSP KONSTANTER (multi-output system power supply) offers extensive flexibility, ease of
operation and economy for universal use in R&D, production and testing.
The MSP KONSTANTER is a modular, manually operated and computer controlled DC power supply. The
basic unit with integrated auxiliary power supply and cooling fan is equipped with IEEE 488 and RS 232
interfaces, and accepts up to four single or 2-channel plug-in power supply modules, and one control
module. The control module allows for manual operation of all 8 channels.
The plug-in modules operate in accordance with the linear controller principle, and the outputs have a
2 quadrant operating range. Source and sink functions are possible for constant voltage as well as
constant current operation. Parallel or series connection, as well as bridging for the generation of
bipolar voltages is possible.
• Up to 8 independent, electrically isolated outputs
• All outputs can be used as electronic loads as well
• Minimal residual ripple and short response times
• Output On/Off function
• Outputs can be activated and deactivated individually or in groups
• Measuring function for voltage, current and power with storage of extreme values
• Online help available in various languages by simply pressing a key
• IEEE 488 and RS 232 interfaces
• Easy, flexible device configuration
• Driver software for LabVIEW, LabWindows CVI and HP VEE
● For optional accessories refer to the table on page 89.
86
Type
Data Sheet No.
64 D 42 P
3-349-084-03
Article Number
K370A
MSP control module
3-349-084-03
K371A
ES 31 K 2x8 R 3 P
3-349-084-03
K372A
ES 31 K 2x16 R 1.5 P
3-349-084-03
K372B
ES 31 K 2x40 R 0.6 P
3-349-084-03
K372C
ES 31 K 7 R 7 P
3-349-084-03
K372D
ES 32 K 30 R 4 P
3-349-084-03
K373A
ES 32 K 80 R 1.5 P
3-349-084-03
K373B
Made in Germany
Analog Controlled Laboratory Power Supplies
SLP KONSTANTER 32 N
Laboratory Power Supplies, Analog Interface: SLP Series
Series SLP 120, 240 and 320 (single output laboratory power supplies) are single output, primary
switched-mode laboratory power supplies for universal use in R&D, production, training and service
applications.
Our innovative BET circuit technology (bidirectional energy transformation) allows for practically load
independent response times.
• Compact design and minimal weight
• Auto-ranging output with 120 W, 240 W or 320 W, minimal power loss
• Output: voltage and current regulated, increased output power for brief intermittent periods
• Very short response times thanks to BET technology, typically 1 ms
• Dynamic sink operation, excellent dynamic control parameters
• Minimal residual ripple
• Output On-Off function
• Manual adjustment with ten-turn potentiometer
• Remote sensing
• Master-slave operation for parallel and series connection
• Protection against excessive temperature
• Floating output terminals at front and rear panel
• Can be electrically and mechanically combined into multi-output devices
• Mounting accessories for 19" racks
• Dimensions: bench-top instrument (W x H x D) 221.5 x 102 x 397.5 mm, for 19" rack: ½19" x 2 standard
height units x 400 mm
• Weight: approx. 2.8 kg
● For optional accessories refer to the table on page 89.
Type
120 W
240 W
320 W
LSP KONSTANTER 23/33 K
Data Sheet No.
Article Number
32 N 20 R 10
3-348-796-03
K220A
32 N 40 R 6
3-348-796-03
K221A
32 N 80 R 3
3-348-796-03
K222A
32 N 20 R 20
3-348-796-03
K230A
32 N 40 R 12
3-348-796-03
K231A
32 N 80 R 6
3-348-796-03
K232A
32 N 32 R 18
3-348-796-03
K234A
Laboratory Power Supplies, Analog Interface: LSP Series
KONSTANTER series LSP 85 devices (laboratory and system power supply) are compact, linear
controlled three output devices with extraordinary control characteristics. They are exceptionally well
suited for universal use in R&D, production, training and service applications.
Control mode indicators display current operating status.
The analog interface includes monitor, auxiliary power supply and signal outputs with status display
and setpoint inputs.
• SELV (safety extra-low voltage)
• Three mutually isolated outputs (at the front panel)
• Constant voltage and constant current operation
• Extremely minimal residual ripple
• Accurate, infinite adjustment of output voltage and current
• Analog interface (for remote control)
• Outputs can be connected for parallel or series operation
• Master-slave operation
• Tracking operation
• Rugged metal housing with carrying handle, suitable for rack-mounting
• Dimensions: bench-top instrument (W x H x D) 219 x 148 x 365 mm, for 19" rack: 3/6 19" x 3 standard
height units x 343 + 45 mm
• Weight: approx. 8.7 kg
● For optional accessories refer to the table on page 89.
Made in Germany
Type
Data Sheet No.
Article Number
33 K 7 EU 5/2x25 R 1 D
–
K270A
87
Laboratory Power Supplies, Linear Controlled
LSP KONSTANTER 32 K
Laboratory Power Supplies, Linear Controlled, LSP 32K Series
Series 32K LSP Konstanters are high precision DC power supplies for use in R&D, production, training
and service applications. Three variants are available with approximately 100 W of output power.
The devices feature excellent regulating accuracy and minimal residual ripple, and outstanding ease of
operation.
• Floating output with safety sockets
• Safe electrical separation
• Output can be switched on and off
• Voltage and current regulating (square wave)
• Rotary encoders for adjusting voltage and current
• Adjustment is also possible with keys
• Multifunctional LCD panel
• Setup memory for 10 device settings
• Safety devices
• Attractive design, benchtop instrument, suitable for mounting to a 19" rack
• Accessories
• Computer control is possible via RS 232 or RS 485
• Dimensions (W x H x D): ½ 19" 2 standard height units, approx. 215 x 100 x 280 mm
• Approx. weight: 6 kg
● Optional accessories: PC interface upon request
Type
108 W
97 W
32 K 18 R 5
✱
Data Sheet No.
Article Number
3-349-254-03
K110A ✱
32 K 36 R 3
3-349-254-03
K111A
32 K 65 R 1,5 ✱
3-349-254-03
K112A ✱
✱ Upon request
SSL – Load KONSTANTER 32 EL
Laboratory Power Supplies: Series SSL – 32 EL
Series SSL Load KONSTANTER 32EL ... electronic loads are high precision direct current sinks for use
in research, product development, production, service and vocational training.
Two types are available with 150 and 300 W input power.
The devices are distinguished by a diverse range of functions and excellent regulating accuracy, as well
as outstanding ease of operation.
• Floating input
• Safe electrical separation
• Output can be switched on and off
• Characteristic current or R curve can be selected
• Settings selected by means of a rotary switch and keypad
• Multifunctional LCD panel
• Memory for device settings, load profile
• Protective functions including, amongst others, adjustable power limiting
• Attractive design, benchtop instrument, suitable for mounting to a 19" rack
• Accessories
• Computer control is possible via RS 232 or RS 485
• Dimensions (W x H x D): approx. 215 x 100 x 280 mm
• Approx. weight: 5 kg
● Optional accessories: PC interface upon request
88
Type
Data Sheet No.
Article Number
32 EL 150 R 30
3-349-297-03
K850A
32 EL 300 R 30
3-349-297-03
K851A
Made in Germany
Accessories and Software for Power Supplies
Panel Mount and OEM Power Supplies
KONSTANTER Accessories
Designation
Type
Article Number
Mains jumper cable, 0.4 m, for KONSTANTER
K991A
K991A
1x32N mounting kit for KONSTANTER
K990A
K990A
2x32N mounting kit for KONSTANTER
K990B
K990B
Bus cable, IEEE - IEEE, 2 m, for KONSTANTER
K931A
K931A
RS 232 bus cable, 0.4 m, for KONSTANTER
K931B
K931B
RS 232 interface cable, 2 m
Z3241
GTZ3241000R0001
Software
Drivers for SSP Konstanter
for LabWindows, LabView V4/V5 and HPVEE
For incorporating our SSP KONSTANTER computer controllable laboratory power supplies into LabWindows, LabView V4/V5 and HPVEE software packages.
• KONSTANTERs can be used ideally with your application
• KONSTANTER functions are easy to use
• Drivers support all of the computer controllable functions of our KONSTANTERs
Download from our Website
Soft Front Panel operating software and driver for standard platforms are available for download from our website:
www.gossenmetrawatt.com Ö Power Supply Technology Ö Software for Power Supplies
Panel Mount Power Supplies
OEM Power Supplies
Power Supplies for Special Applications, or in Accordance with
Customer Specifications
In addition to our standard power supply series, we also fabricate power supplies
for special applications, or in accordance with customer specifications, for
example:
● Fixed voltage switched-mode power supplies in European plug-in module or cartridge format
● Electronic lamp ballasts for halogen metal-vapor lamps
● 24 to 12 V DC-DC converters for commercial vehicles
● Customer-specific power supplies
Address enquiries to: Phone: +49 (0)911 8602-717
Fax: +49 (0)911 8602-102
e-mail: [email protected]
Made in Germany
89
Energy Meters – Standard Models
U1281...U1389, U389A/B
Electrical Energy Meters
World Class Meters
Electrical Energy Meters for Household, Industrial and Building Management Applications
• Can be calibrated
Approved for official billing in accordance with calibration legislation
• Easy to install
Indicates correct connection
• Compact
Fits in small distributors
• Communication functions
Can be connected to data logging and billing systems
● Optional accessories: U270A door mounting kit for top-hat rail meter,
ASK... or WSK... plug-on and wound-primary current transformer,
UBAT-24V battery pack for reading voltage-free meters,
(See data sheet or Industrial Measuring and Control Technology price list.)
Energy Meters and Calibration from a Single Source
Calibrated meters are required for energy billing purposes in business and official
applications. GOSSEN METRAWATT’s federally approved EB8 test laboratory
calibrates the meters directly at the factory.
Active Energy Meter with Power Display Active Energy Meter, Drum-Type Counter
Direct Connection Transformer Connection Direct Connection Trans. Connection
❍ ✝ order option
5 (65) A
5 (6) A and 1 (6) A
5 (65) A
5 (6) A and 1 (6) A
● ✝ default
Mains type
2-wire
U1281
U1381
U1387
3-wire
4-wire
U1289
U1389
U389A
U389B
❍
❍
Input voltage
100 V-110 V L-L
●
●
230 V L-N
400 V L-L
●
❍
❍
●
●
❍
500 V L-L
Transformer ratios
CT, VT adjustable
❍
❍
❍
Multifunctional variant
With additional meas. of U, I, P, Q, S, PF, F
❍
❍
❍
❍
❍
Class
1
●
●
●
●
●
●
●
Can be calibrated
●
●
●
●
●
S0 pulse output
S0 standard
❍
❍
❍
❍
❍
●
●
230 V
❍
❍
❍
❍
❍
Adjustable pulse rate, pulse duration
❍
❍
❍
❍
❍
Bus connection
LON
❍
❍
❍
❍
❍
M-Bus
❍
❍
❍
❍
❍
L-bus
❍
❍
❍
❍
❍
Can be read via voltage-free meas. circuit With help of ext. 24 V DC aux. power
❍
❍
❍
❍
❍
E
Immediately Available Standard Models
Data Sheet No.
Article Number
Active energy meter with power display, direct connection: 5 (65) A, class 1
for 2-wire, 230 V system, programmable S0 pulse rate
3-349-274-03
for 2-wire, 230 V system, S0: 1000 pulses per kWh, calibrated
3-349-274-03
U1281-V001
U1281-V002
for 4-wire system, 3 ea. 230 / 400 V, S0, 1000 pulses per kWh
3-349-274-03
U1289-V001
for 4-wire system, 3 ea. 230 / 400 V, S0, 1000 pulses per kWh, calibrated
3-349-274-03
U1289-V002
for 4-wire system, 3 ea. 230 / 400 V, programmable S0 pulse rate
3-349-274-03
U1289-V003
Active energy meter with power display, transformer connection: 5 (6) A and 1 (6) A, class 1
for 2-wire system, 230 V, 5//1 A, S0, CT / VT / programmable pulse rate
3-349-274-03
for 2-wire system, 230 V, 5//1 A, S0, 1000 pulses per kWh, CT = VT = 1, calibrated
3-349-274-03
U1381-V001
U1381-V002
for 3-wire system, 3 ea. 100 V, 5//1 A, S0, CT / VT / programmable pulse rate
3-349-274-03
U1387-V001
for 3-wire system, 3 ea. 100 V, 5//1 A, S0, 1000 pulses per kWh, CT = VT = 1, calibrated
3-349-274-03
U1387-V002
for 3-wire system, 3 ea. 400 V, 5//1 A, S0, CT / VT / programmable pulse rate
3-349-274-03
U1387-V003
for 3-wire system, 3 ea. 400 V, 5//1 A, S0, 1000 pulses per kWh, CT = VT = 1, calibrated
3-349-274-03
U1387-V004
for 4-wire system, 3 ea. 230 / 400 V, 5//1 A, S0, CT / VT / programmable pulse rate
3-349-274-03
U1389-V001
for 4-wire system, 3 ea. 230 V, 5//1 A, S0, 1000 pulses per kWh, CT = VT = 1, calibrated
3-349-274-03
U1389-V002
for 4-wire system, 3 ea. 230 / 400 V, 5//1 A, S0, CT / VT / programmable pulse rate, LON
3-349-274-03
U1389-V003
for 4-wire system, 3 ea. 230 V, 5//1 A, S0, 1000 pulses per kWh, CT = VT = 1, LON, calibrated
3-349-274-03
U1389-V004
Active energy meter with drum-type counter mechanism, U389A with direct connection: 5 (65) A, U389B with transformer connection: 5 (6) A and 1 (6) A, class 1
for 4-wire system, 3 ea. 230 / 400 V, 5 (65) A, S0: 100 pulses per kWh
3-349-321-03
U389A
for 4-wire system, 3 ea. 230 / 400 V, 5//1 A, S0: 1000 pulses per kWh
3-349-321-03
U389B
90
Made in Germany
Training and Seminars with Practical Experience
Training and Seminars
An economic advantage can only be gained through the use of modern, high quality measuring and test
instruments if they are operated by motivated, qualified employees.
As a service to the customer, GOSSEN METRAWATT offers seminars and workshops to this end, which, in addition
to theoretical, technical and legal considerations, place an emphasis on practical experience as well. Imparted
knowledge can be implemented directly in the actual work environment, and promotes efficient, error-free work.
We can offer seminars at our own training center in Nuremberg, at your facility or at hotels in close proximity to
your offices so that you don’t waste your valuable time traveling long distances.
Short travel distances and regional offerings assure minimal time loss.
Training Hotline
+49-911 8602-406
(seminar catalog, advice, registration, prices)
Type
Designation
Article Number
Testing of Safety Measures
GTT1210
Measurements for testing safety measures in low-voltage systems per DIN VDE 0100/0105 and BGV A3
(VBG 4) with PROFITEST 0100S-II, PROFITEST ONE and PROFITEST C instruments (seminar duration: 2 days)
GTT1210000R0001
GTT1211
Efficient periodic testing of portable electrical equipment according to requirements set forth by BGV A3
(VBG 4) with SECUTEST SII and SIII test instruments (seminar duration: 2 days)
GTT1211000R0001
GTT1212
Periodic testing of electrical equipment by “trained persons” according to requirements set forth by BGV A3
with SECUTEST SII, MINITESTER 702 and METRATESTER 5 test instruments (seminar duration: 1 day)
GTT1212000R0001
GTT1213
Safety tests for medical devices with the SECUTEST 0751 / 601 or SECUTEST SIII
(seminar duration: 1 day)
GTT1213000R0001
GTT1214
Safety test for electrically operated hospital beds with SECUTEST SII and SECUTEST SIII test instruments
(seminar duration: 1 day)
GTT1214000R0001
GTT1215
Measurements for testing electrical equipment at machinery per DIN VDE 0113 (EN 60204) with PROFITEST 204
and METRAMACHINE 204 (seminar duration: 1 day)
GTT1215000R0001
GTT1216
Basic Electro-Technical Training – basic electro-technical knowledge, dangers of electricity for “trained persons”,
as a supplement to seminars GTT1212 and GTT1214 (seminar duration: 2 days)
GTT1216000R0001
GTT1216
Basic Electro-Technical Training – basic electro-technical knowledge, dangers of electricity for “trained persons”,
as a supplement to seminars GTT1212 and GTT1214 (seminar duration: 3 days)
GTT1216000R0001
GTT3010
Efficient testing for building management in accordance with BGV A3, BetrSichV, MPG and DIN VDE regulations
with the SECUSTAR FM modular test system (seminar duration: 2 days)
GTT3010000R0001
GTT5010
Testing of single and 3-phase portable equipment with the SECUTEST 3P/3PL test case
(seminar duration: 1 day)
GTT5010000R0001
Measuring with Multimeters
GTT1219B
Safe, correct and efficient measurement, recording and analysis with METRA HIT multimeters and METRAwin10
software (seminar duration: 1 day)
GTT1219000R0001
PC Analysis Software for SECUTEST ... and PROFITEST ... Test Instruments (seminar duration: 1 day each)
GTT1224A
PS3 application software, basics, devices, software and equipment management for measurements at devices with SECUTEST ... GTT1224000R0001
GTT1224B
PS3 application software, basics, systems, software and test management for measurements at systems with PROFITEST ... GTT1224000R0001
GTT1224C
PS3 user software, basics for measurements at machines with the PROFITEST 204 and the METRAMACHINE 204 GTT1224000R0001
GTT1224D
PS3-compact user software, basics for measurements at devices with SECUTEST ...
GTT1224E
PS3-compact user software, basics for measurements in systems with PROFITEST ...
GTT1224000R0001
GTT1226
PC.doc-ACCESS user software
GTT1226000R0001
GTT1227A
ELEKTROmanager software for testing portable electrical equipment
with SECUTEST ...
GTT1227000R0001
GTT1227B
ELEKTROmanager software for testing low-voltage systems including permanently connected
equipment with PROFITEST ...
GTT1227000R0001
GTT1224000R0001
Internet Seminar: e-Learning
GTT1228
Internet seminar for PS3 user software, administration of test and device data for electrical equipment with
SECUTEST ... (seminar duration: three 2 hour sessions)
GTT1228000R0001
GTT1643
Power disturbance analysis, as well as power and energy analysis with the MAVOWATT 50 and appropriate
software (seminar duration: 2 days)
GTT1642
Power disturbance analysis, as well as power and energy analysis with the MAVOLOG 10 (seminar duration: 1 day) GTT1642000R0001
Power Disturbance Analysis
Made in Germany
GTT1643000R0001
91
Space for Personal Notes
92
Made in Germany
Type Index
Numerics
1081 probe ................................................. 65, 72, 75
1ASi battery set ....................................................... 22
1-Ch. Pack II ............................................... 28, 29, 35
1x32N mounting kit ................................................. 89
2x32N mounting kit ................................................. 89
32 EL 150 R 30 ................................................ 84, 88
32 EL 300 R 30 ...................................................... 88
33 K 7 EU 5/2x25 R 1 D .................................... 84, 87
3-pole adapter .................................................. 50, 75
3-pole adapter / CH ................................................. 50
3-pole adapter / UK ................................................. 50
3-pole adapter for DC-II ..................................... 47, 49
4 rechargeable NiMH, EX approval ........................... 21
4-Ch. Pack II ............................................... 28, 29, 35
64 N 52 RU 100 P ............................................. 84, 85
64 N 52 RU 150 P ............................................. 84, 85
A
A3-16 .............................................................. 71, 75
A3-32 .............................................................. 71, 75
A3-63 .............................................................. 71, 75
Accessories for SECUSTAR FM ................................... 7
Adapter disc ..................................................... 38, 39
AF033A ................................................ 28, 29, 31, 41
AF101A ................................................ 28, 29, 31, 41
AF11A .................................................. 28, 29, 31, 41
AF33A .................................................. 28, 29, 31, 41
ASi.doc-win ............................................................ 23
ASi-access ............................................................. 23
ASi-Pack 1 ........................................................ 22, 23
AT16-DI .................................................................... 7
AT32-DI .................................................................... 7
AT3-IIIE ............................................................ 61, 75
AT3-IIS ............................................................. 61, 75
B
B3261 .............................................................. 73, 75
Battery set 0100S ................................................... 49
BD232 ........................................................ 28, 29, 35
BD-Pack 1 .................................................. 28, 29, 35
Brush probe ........................................................ 7, 61
C
Cable Lug 204 ........................................................ 53
CableCop 300 ......................................................... 82
Caddy 204 ........................................................ 53, 64
Calculating disc ....................................................... 38
CEE Adapter ............................................................ 75
CEE-CHECK 32/400 ................................................ 48
CF3x45 .................................................................. 41
Claim 204 ............................................................... 53
Clip 0100S ............................................................. 49
Clip-on adapter cable .............................................. 49
CP28 Calibrator Pack .............................................. 25
D
DA-II ........................................................... 64, 71, 75
E
EL1 .................................................................. 72, 75
ELEKTROmanager ................................................... 76
ELEKTROmanager 4.0 ............................................. 78
ELEKTROmanager 4.5 ............................................. 78
EMA1 ......................................................... 28, 29, 33
ES 31 K 2x16 R 1.5 P plug-in module ................ 84, 86
ES 31 K 2x40 R 0.6 P plug-in module ................ 84, 86
ES 31 K 2x8 R 3 P plug-in module ..................... 84, 86
E-Set 3 ................................................................... 69
E-Set 4 ................................................................... 69
E-Set 5 ................................................................... 69
Made in Germany
F
K
F2000 ...................................7, 49, 53, 57, 65, 74, 75
F2000 carrying pouch ..............................................64
F2010 .......................................................................7
F500mA/250V .........................................................27
F801 .......................................................................70
F809 .................................................................18, 27
F822 .................................................................20, 27
F823 .................................................................18, 27
F825 .................................................................22, 27
F829 .................................................................18, 27
F833 .......................................................................68
F836 .......................................................................27
F837 .................................................................63, 65
F840 .......................................................................27
F841 .................................................................19, 27
Factory certificate ..............................................38, 39
FF (UR)10A/1kV AC/DC ......................................11, 27
FF 1A/380V (5 x 20) ................................................27
FF 6.3 A / 500 V ......................................................27
FF 630 mA / 700 V ..................................................27
FF (UR) 1.6 A/1000 V AC/DC ....................................27
FF (UR) 16 A/1000 V AC/DC .....................................27
FF(UR) 1.6 A / 700 V AC ..........................................27
FF(UR)16 A/500 V AC? 27 ........................................27
FMA1 ..........................................................28, 29, 33
K2000 ........................................................ 49, 74, 75
K2010 .................................................... 7, 57, 74, 75
K931A .................................................................... 89
K931B .................................................................... 89
K990A .................................................................... 89
K990B .................................................................... 89
K991A .................................................................... 89
KC27 ................................................................ 28, 29
KC27 Set ................................................................ 34
KC4 .................................................................. 28, 29
KC4 Set .................................................................. 34
KS13 .......................................................... 55, 71, 75
KS14 ...................................................................... 19
KS17-2 .......................................... 28, 29, 34, 71, 75
KS17-ONE .................................................. 28, 29, 34
KS17S ........................................................ 28, 29, 34
KS24 .................................................... 65, 66, 71, 75
KS28 ...................................................................... 26
KS29 ................................................................ 15, 26
KS30 .......................................................... 28, 29, 31
KS31A .................................................................... 22
KS31B .................................................................... 22
KS31C .................................................................... 22
KS36A .................................................................... 23
KS36B .................................................................... 23
KS36C .................................................................... 23
KS36E .............................................................. 22, 23
KS-C ...................................................................... 62
KY 5000A ................................................... 64, 65, 75
KY94 .......................................................... 28, 29, 34
KY95-1 ....................................................... 28, 29, 34
KY95-2 ....................................................... 28, 29, 34
KY96 .......................................................... 28, 29, 34
G
Generator 5000A .....................................................65
GEOHM 33D ............................................................68
GEOHM C ................................................................67
GH X-TRA ................................................................11
GH18 ................................................................27, 70
GH185 ..............................................................18, 27
GH19 ................................................................19, 27
GTT1210 ................................................................91
GTT1211 ................................................................91
GTT1212 ................................................................91
GTT1213 ................................................................91
GTT1214 ................................................................91
GTT1215 ................................................................91
GTT1216 ................................................................91
GTT1219 ................................................................91
GTT1224A ..............................................................91
GTT1224B ..............................................................91
GTT1224C ..............................................................91
GTT1224D ..............................................................91
GTT1224E ...............................................................91
GTT1226 ................................................................91
GTT1227A ..............................................................91
GTT1227B ..............................................................91
GTT1228 ................................................................91
GTT1642 ................................................................91
GTT1643 ................................................................91
GTT3010 ................................................................91
GTT5010 ................................................................91
Guard 5000A ..............................................64, 65, 75
H
HC20 ................................................................22, 27
HC30 ......................................................................27
HC30-C ............................................................50, 67
HC40 ......................................................................50
HitBag .....................................................................27
HV3 ............................................................28, 29, 31
HV30 ..........................................................28, 29, 31
I
IEEE - IEEE bus cable, 2 m .......................................89
IEEE 488 interface ...................................................85
IEEE488 / RS 232 interface ......................................85
IrDa 0100S .......................................................23, 75
IrDa-USB converter ......................................48, 67, 73
ISO calibrator 1 ..................................................64, 66
L
Leadex 204 ............................................................ 53
LEADEX 5000 ......................................................... 64
Leadex 5000 .................................................... 65, 75
LSP-KONSTANTER
32 K 18 R 6 .................................................. 84
32 K 36 R 3 .................................................. 84
32 K 65 R 1,5 ............................................... 84
Luminance attachment ............................................ 38
M
M125A/250V .......................................................... 27
Mains jumper cable, 0.4 m ...................................... 89
MAVOLOG 10 Mobile Set ......................................... 42
MAVOLOG 10L ....................................................... 42
MAVOLOG 10N ....................................................... 42
MAVOLOG 10S ....................................................... 42
MAVOLOG BP ......................................................... 43
MAVOLOG Dial-Up .................................................. 43
MAVOLOG PS / C .................................................... 43
MAVOLOG PS / C universal ...................................... 43
MAVOLUX 5032 B USB ............................................ 38
MAVOLUX 5032 C USB ........................................... 38
MAVOLUX 5032B USB ............................................... 7
MAVO-MONITOR USB .............................................. 39
MAVOWATT 4 ......................................................... 26
MAVOWATT 50 ....................................................... 40
METRA HIT 16I ....................................................... 16
METRA HIT 16I Set 1 ............................................... 16
METRA HIT 16I Set 2 ............................................... 16
METRA HIT 16U ...................................................... 17
METRA HIT 1A ........................................................ 18
METRA HIT 1ASi ..................................................... 22
METRA HIT 22M ..................................................... 12
METRA HIT 22S ...................................................... 12
METRA HIT 22S with protective rubber cover ............ 12
METRA HIT 24S ...................................................... 13
METRA HIT 26M ..................................................... 14
METRA HIT 26S ...................................................... 14
METRA HIT 27AS .................................................... 21
METRA HIT 27EX .................................................... 21
METRA HIT 27I ....................................................... 21
METRA HIT 27M ..................................................... 21
93
Type Index
METRA HIT 28C ...................................................... 24
METRA HIT 28c light ............................................... 24
METRA HIT 28S ...................................................... 15
METRA HIT 29S ................................................ 15, 26
METRA HIT 29S Set 1 ....................................... 15, 26
METRA HIT 2A ........................................................ 18
METRA HIT 30M ..................................................... 16
METRA HIT 6T ........................................................ 17
METRA HIT ONE ...................................................... 12
METRA HIT ONE plus ............................................... 12
METRA HIT ONE with protective rubber cover ............ 12
METRA HIT23S ....................................................... 13
METRA HIT25S ....................................................... 14
METRA l VIEW ......................................................... 11
METRACLIP 50 ....................................................... 80
METRACLIP 51 ....................................................... 80
METRACLIP 60 ....................................................... 80
METRACLIP 70 ....................................................... 80
METRACLIP 71 ....................................................... 80
METRACLIP 72 Power ............................................. 81
METRACLIP 73 ....................................................... 81
METRACLIP 74 ....................................................... 81
METRACLIP 75 Automotive ...................................... 81
METRACLIP 80 ....................................................... 81
METRACLIP 81 ....................................................... 81
METRAHIT l BASE ................................................... 10
METRAHIT l PRO ..................................................... 10
METRAHIT l X-TRA .................................................. 11
MetraMachine 204/2.5 ........................................... 52
MetraMachine 204-I/2.5 ......................................... 52
MetraMachine 439/5.4 ........................................... 52
METRAmax 12 ........................................................ 18
METRAmax 12 Set 1 ............................................... 18
METRAmax 2 .......................................................... 19
METRAmax 3 .......................................................... 19
METRAmax 6 .......................................................... 22
METRAOHM 413 ..................................................... 62
MetraPhase 1 ......................................................... 70
METRAport 32S ...................................................... 20
METRAport 32XS .................................................... 20
METRAport 3A ........................................................ 20
METRAtest 36ASi .................................................... 23
METRATESTER 5 ..................................................... 54
METRATESTER 5-3P ......................................... 55, 79
METRATESTER 5-F-E .............................................. 54
METRAVOLT 12D .................................................... 82
METRAVOLT 7A ...................................................... 82
METRAwin 10 / METRAHit ................................. 28, 29
METRAwin 10 Software Update ................................ 36
METRAwin 90-2 ...................................................... 37
METRAwin 90-F ...................................................... 37
METRAwin 90-FJ .................................................... 37
METRAwin10 / MAVOLOG ....................................... 44
METRAwin90-2 ................................................. 28, 29
METRISO 1000A ..................................................... 65
METRISO 1000D ..................................................... 63
METRISO 1000IR .................................................... 63
METRISO 5000A ..................................................... 65
METRISO 5000AK ................................................... 65
METRISO 5000AK-Set ............................................. 65
METRISO 5000A-Set ............................................... 65
METRISO 5000D-PI ................................................. 64
METRISO 500D ....................................................... 63
METRISO 5024 in pouch ......................................... 66
METRISO C ............................................................. 62
MINITEST BASE ....................................................... 54
MINITEST PRO ........................................................ 54
MSP-KONSTANTER
64 D 42 P ............................................... 84, 86
ES 31 K 7 R 7 P ...................................... 84, 86
ES 32 K 30 R 4 P .................................... 84, 86
ES 32 K 80 R 1,5 P ................................. 84, 86
MSP control module ................................. 84, 86
94
N
S
NA 0100S ................................................... 23, 49, 67
NA X-TRA ............................................................... 11
NA4/500 ............................................... 28, 29, 34, 70
NA5/600 ..................................................... 28, 29, 34
NiMH Schnell-Ladegerät, EX ..................................... 21
NW10A ................................................................... 19
NW300mA .................................................. 28, 29, 30
NW3A ......................................................... 28, 29, 30
SECU-cal 10 ..................................................7, 60, 75
SECUSTAR FM ...........................................................6
SECUTEST 21F ........................................................79
SECUTEST 3PL ........................................................59
SECUTEST PSI .......................................52, 59, 64, 75
SECUTEST SII ..........................................................56
M7030-V001 .................................................56
M7030-V002 .................................................56
M7030-V003 .................................................56
M7030-V005 .................................................56
SECUTEST SIII ..........................................................57
M7010-V001 .................................................57
M7010-V010 .................................................57
SECU-Up .................................................................76
Set 1ASi ..................................................................22
Set 36 ASi ...............................................................23
Set PROFiTEST C/METRISO C ...................................50
Set PROFiTEST C / METRISO C .................................62
Set PROFiTEST C / METRISO C-CH ...........................50
SI232 II .......................................................28, 29, 35
Signal 204 .........................................................53, 64
SK2 ...................................................................60, 75
SK5 .............................................................60, 75, 76
SLP-KONSTANTER
31 N 32 R 18 .................................................84
32 K 18 R 6 ...................................................88
32 K 36 R 3 ...................................................88
32 K 65 R 1,5 ................................................88
32 N 20 R 10 ...........................................84, 87
32 N 20 R 20 ...........................................84, 87
32 N 32 R 18 .................................................87
32 N 40 R 12 ...........................................84, 87
32 N 40 R 6 .............................................84, 87
32 N 80 R 3 .............................................84, 87
32 N 80 R 6 .............................................84, 87
SM16 ..........................................................28, 29, 33
SP350 .........................................................68, 72, 75
SSP-KONSTANTER
32 N 20 RU 10 P ......................................84, 85
32 N 20 RU 20 P ......................................84, 85
32 N 32 RU 18 P ......................................84, 85
32 N 40 RU 12 P ......................................84, 85
32 N 40 RU 6 P ........................................84, 85
32 N 80 RU 3 P ........................................84, 85
32 N 80 RU 6 P ........................................84, 85
62 N 52 RU 25 P ......................................84, 85
62 N 52 RU 50 P ......................................84, 85
62 N 80 RU 12.5 P ...................................84, 85
62 N 80 RU 25 P ......................................84, 85
64 N 80 RU 50 P ......................................84, 85
64 N 80 RU 75 P ......................................84, 85
STOP 204 ...............................................................53
P
PA4 .................................................................. 61, 75
PC.base-upgrade .................................................... 76
PC.doc-ACCESS ...................................................... 76
PC.doc-ACCESS / MAVOLOG ................................... 44
PC.doc-upgrade ...................................................... 76
PC.doc-WORD ......................................................... 76
PGS 117T ............................................................... 46
PGS 2000 ............................................................... 46
PGS 210 ................................................................. 46
PGS 211 ................................................................. 46
PGS 215 ................................................................. 46
PGS 216 ................................................................. 46
PhaseCop 2 ............................................................ 70
PMA16 ....................................................... 28, 29, 33
PRO-A3 .................................................................. 49
PRO-CH ...................................................... 49, 72, 75
PROFi TEST 204HP-2.5kV ....................................... 52
PROFi TEST 204HV-5.4kV ........................................ 52
PROFi TEST DC II ..................................................... 47
PROFi TEST PSI-BC ................................................. 47
PROFi TEST PSI-E .................................................... 47
PROFi TEST SI-BC ................................................... 47
PROFI-MFI I ............................................................. 53
ProfiSafe 1 .............................................................. 82
PROFiTEST 0100S-E-II ............................................ 45
PROFiTEST 0100S-II ................................................ 45
PROFiTEST 0100S-O-II ............................................ 45
PROFiTEST 0100S-UK-II .......................................... 45
PROFITEST 204 ....................................................... 51
PROFITEST 204HP/2.5 kV ........................................ 64
PROFITEST 204HP/5.4 kV ........................................ 64
PROFITEST 204L ..................................................... 51
PROFiTEST C .......................................................... 50
PROFiTEST C-CH ..................................................... 50
PROFITEST ONE ...................................................... 46
PRO-GB ...................................................... 49, 72, 75
PRO-RLO ................................................................ 49
PRO-RSA .................................................... 49, 72, 75
PRO-Schuko ........................................................... 49
PRO-UNI ................................................................. 49
PS-10P ....................................................... 52, 59, 75
PS3 ........................................................................ 76
PS3 AM .................................................................. 77
PS3 Client ............................................................... 77
PS3 Compact .......................................................... 77
PS3 GM .................................................................. 77
PS3 Hazard Analysis ................................................ 77
PS3 Maintenance Contract ....................................... 77
PS3 Navigator ......................................................... 77
PS3 update ............................................................. 77
PS3 upgrade ........................................................... 77
R
Remote 204 ...................................................... 53, 76
RS 232 – USB converter ........................ 48, 53, 73, 75
RS 232 bus cable, 0.4 m ......................................... 89
RS 232 interface cable, 2 m ..................................... 89
RS232 interface ...................................................... 85
T
T 16A/500V (6.3 x 32) .............................................27
T/H sensor ...............................................................47
Telearm1 ...........................................................72, 75
TF220 .........................................................28, 29, 32
TF400CAR ...................................................28, 29, 32
TF550 .........................................................28, 29, 32
TR25 ...........................................................68, 72, 75
TR50 ...........................................................68, 72, 75
TS Chipset ...................................................28, 29, 32
U
USB X-TRA interface adapter ....................................11
USB-Hit .......................................................28, 29, 35
USB-Pack ....................................................28, 29, 35
Made in Germany
Type Index
V
Variable plug adapter set ......................................... 71
visual FM .................................................................. 7
VL15 extension cable, 15 m ..................................... 21
VL2 ............................................................ 55, 60, 75
VL2 test adapter ...................................................... 79
W
WinProfi .................................................................. 76
WZ11A ....................................................... 28, 29, 30
WZ11B ................................................. 28, 29, 30, 41
WZ12A ....................................................... 28, 29, 30
WZ12B ....................................................... 28, 29, 30
WZ12C ..................................... 28, 29, 30, 57, 60, 75
WZ12D ....................................................... 28, 29, 30
Z
Z13B .................................................... 28, 29, 30, 41
Z201A .................................................. 28, 29, 30, 41
Z202A .................................................. 28, 29, 30, 41
Z203A .................................................. 28, 29, 30, 41
Z3210 ........................................................ 52, 59, 75
Z3241 ...................................... 28, 29, 34, 35, 47, 89
Z3409 ...................................... 28, 29, 32, 57, 72, 75
Z3431-2 ..................................................... 28, 29, 31
Z3431-3 ..................................................... 28, 29, 32
Z3431-4 ..................................................... 28, 29, 32
Z3431-5 ..................................................... 28, 29, 32
Z3431-6 ..................................................... 28, 29, 32
Z3431-7 ..................................................... 28, 29, 32
Z3431-8 ..................................................... 28, 29, 32
Z3431-9 ..................................................... 28, 29, 32
Z3450 ........................................................ 28, 29, 33
Z3511 ........................................................ 28, 29, 30
Z3512 ........................................................ 28, 29, 30
Z3512A .......................................... 28, 29, 30, 41, 49
Z3514 ........................................................ 28, 29, 30
Z500A .............................................................. 70, 75
Z504J .............................................................. 49, 74
Z580A .................................................................... 75
Z721D .......................................................... 7, 73, 75
Z722D .......................................................... 7, 73, 75
Z722E .......................................................... 7, 73, 75
Z745A .............................................................. 55, 59
Z745G .............................................................. 55, 75
Z751A ...................................................................... 7
Z751B ...................................................................... 7
Z753A ...................................................................... 7
Z753B ...................................................................... 7
Z821B .................................................................... 41
Z860A .................................................................... 41
Z861A .................................................................... 41
Z862A .................................................................... 41
Z863A .................................................................... 41
Z864A .................................................................... 57
Made in Germany
95
Article Number Index
Numerics
5908V0120 ................................... 38
5999V0380................................... 38
G
GTM3033000R0001 ...................... 26
GTM3060000R0001 ...................... 22
GTM5016000R0001 ................ 52, 59
GTM5027000R0001...................... 51
GTM5033000R0001...................... 68
GTM5040000R0001...................... 63
GTM5050000R0001 ...................... 63
GTM5050000R0002....................... 63
GTM5202000R0001...................... 70
GTM5292000R0001...................... 82
GTM9070190E0002 ...................... 33
GTT1210000R0001....................... 91
GTT1211000R0001 ....................... 91
GTT1212000R0001....................... 91
GTT1213000R0001....................... 91
GTT1214000R0001 ....................... 91
GTT1215000R0001 ....................... 91
GTT1216000R0001 ....................... 91
GTT1219000R0001 ....................... 91
GTT1224000R0001 ....................... 91
GTT1226000R0001 ....................... 91
GTT1227000R0001 ....................... 91
GTT1228000R0001....................... 91
GTT1642000R0001 ....................... 91
GTT1643000R0001....................... 91
GTT3010000R0001....................... 91
GTT5010000R0001 ....................... 91
GTY1040014E34 ..................... 68, 72
GTY3171185P01 ..................... 18, 27
GTY3172070P01 ........................... 70
GTY3172083P01 ..................... 18, 27
GTY3172095P01 ..................... 20, 27
GTY3172097P01 ..................... 18, 27
GTY3172100P01..................... 22, 27
GTY3610094P01........................... 34
GTY3610096P01........................... 34
GTY3620034P0002 ................. 34, 71
GTY3620065P0001 ....................... 26
GTY3624065P01..................... 55, 71
GTZ0156000R0001 ....................... 19
GTZ3196000R0001 ................. 65, 72
GTZ3201000R0001 ........... 65, 66, 71
GTZ3204000R0001 ....................... 31
GTZ3210000R001 ................... 52, 59
GTZ3212000R0001 ................. 27, 70
GTZ3214000R0001 ....................... 49
GTZ3214000R0002 ....................... 49
GTZ3214000R0003 ....................... 49
GTZ3215000R0002 ....................... 34
GTZ3225000R0001 ................. 49, 72
GTZ3226000R0001 ................. 49, 72
GTZ3228000R0001 ....................... 49
GTZ3229000R001 ................... 52, 59
GTZ3231020R0001 ....................... 35
GTZ3232000R0001 ....................... 72
GTZ3234020R0001 ....................... 35
GTZ3240000R0001 ....................... 36
GTZ3241000R0001 ................. 34, 89
GTZ3241000R0001A1 ............. 35, 47
GTZ3242020R0001 ....................... 35
GTZ3242100R0001 ....................... 35
GTZ3261000R0001 ....................... 73
GTZ3301000R0003 ................. 18, 27
GTZ3301001R0001 ....................... 68
GTZ3301005R0001 ....................... 69
GTZ3302000R0001 ....................... 27
GTZ3302001R0001 ....................... 27
GTZ3303000R0001 ................. 68, 72
96
GTZ3304000R0001
GTZ3312000R0001
GTZ3406000R0001
GTZ3408000R0001
GTZ3409000R0001
GTZ3431001R0001
GTZ3431002R0001
GTZ3431003R0001
GTZ3431004R0001
GTZ3431005R0001
GTZ3431006R0001
GTZ3431007R0001
GTZ3431008R0001
GTZ3431009R0001
GTZ3431011R0001
GTZ3450000R0001
GTZ3511000R0001
GTZ3512000R0001
GTZ3514000R0001
GTZ3602000R0001
GTZ3603000R0001
GTZ3604000R0001
................. 68, 72
................. 63, 65
....................... 32
....................... 32
........... 32, 57, 72
....................... 31
....................... 31
....................... 32
....................... 32
....................... 32
....................... 32
....................... 32
....................... 32
....................... 32
....................... 31
....................... 33
....................... 30
....................... 30
....................... 30
....................... 71
....................... 71
....................... 71
H
H997B ..................................... 38, 39
K
K110A
K111A
K112A
K220A
K221A
K222A
K230A
K231A
K232A
K234A
K270A
K320A
K321A
K322A
K330A
K331A
K332A
K334A
K341A
K343A
K344A
K345A
K351A
K352A
K361A
K362A
K370A
K371A
K372A
K372B
K372C
K372D
K373A
K373B
K380A
K382A
K383A
K850A
K851A
K931A
K931B
K990A
K990B
K991A
........................................... 88
........................................... 88
........................................... 88
........................................... 87
........................................... 87
........................................... 87
........................................... 87
........................................... 87
........................................... 87
........................................... 87
........................................... 87
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 85
........................................... 86
........................................... 86
........................................... 86
........................................... 86
........................................... 86
........................................... 86
........................................... 86
........................................... 86
........................................... 85
........................................... 85
........................................... 85
........................................... 88
........................................... 88
........................................... 89
........................................... 89
........................................... 89
........................................... 89
........................................... 89
M
M100A ..........................................18
M101A ..........................................18
M102A ..........................................19
M103A ..........................................19
M113A ..........................................20
M204B ..........................................12
M204C ..........................................12
M204D ..........................................12
M212A ..........................................18
M212D ..........................................18
M216A ..........................................17
M216B ..........................................16
M216E ...........................................16
M216F ...........................................16
M216U ..........................................17
M222A ..........................................12
M222B ..........................................12
M222F ...........................................12
M223A ..........................................13
M224A .......................................... 13
M225A ..........................................14
M226A ..........................................14
M226B ..........................................14
M227A ..........................................21
M227B ..........................................21
M227C ..........................................21
M227D ..........................................21
M228A ..........................................15
M229A ....................................15, 26
M229E .....................................15, 26
M230B ..........................................16
M231A ..........................................24
M231B ..........................................25
M232A ..........................................24
M234A ..........................................20
M234C ..........................................20
M235A ..........................................22
M235C ..........................................22
M236A ..........................................23
M236B ..........................................23
M240A ..........................................11
M241A ..........................................10
M242A ..........................................10
M300A ..........................................80
M300B ..........................................80
M311C ..........................................80
M311D ..........................................80
M311E ...........................................81
M312A ..........................................80
M312B ..........................................80
M312C ..........................................81
M312D ..........................................81
M312F ...........................................81
M312G ..........................................81
M312H ..........................................81
M499G ....................................38, 39
M502G ..........................................38
M503G ..........................................38
M504D ..........................................52
M504E ...........................................52
M504F ...........................................52
M504G .......................................... 39
M505A ..........................................52
M505B ..........................................52
M505C ..........................................51
M508A ....................................50, 62
M508B ..........................................50
M509L ...........................................46
M509M ..........................................46
M509P .......................................... 46
M509R ..........................................46
M509S .......................................... 46
M509T .......................................... 46
M520A .......................................... 45
M520B .......................................... 45
M520C .......................................... 45
M520D .......................................... 45
M520G .......................................... 46
M521A .......................................... 50
M521B .......................................... 50
M522A .......................................... 47
M522D .......................................... 47
M522E .......................................... 47
M523A .......................................... 47
M540C .......................................... 65
M540E .......................................... 66
M541A .......................................... 62
M580A .......................................... 65
M580C .......................................... 65
M580S .......................................... 65
M580T .......................................... 65
M5810 .......................................... 64
M5810B1 ...................................... 64
M5810B2 ...................................... 64
M5810C1 ...................................... 64
M5810D1 ...................................... 64
M5810F1 ...................................... 64
M5810G1 ...................................... 64
M5810H1 ...................................... 64
M5810I1 ....................................... 64
M5810-V001 ................................ 64
M590A .......................................... 67
M601A .......................................... 79
M620A .......................................... 70
M630A .......................................... 62
M630B .......................................... 82
M630C .......................................... 82
M630D .......................................... 82
M662A .................................... 64, 66
M662C .......................................... 48
M700D .......................................... 54
M700S .................................... 55, 79
M700T .......................................... 54
M7010.......................................... 57
M7010B01 .................................... 57
M7010B11 .................................... 57
M7010E01 .................................... 57
M7010F02 .................................... 57
M7010G01 .................................... 57
M7010J01 .................................... 57
M7010KA01 .................................. 57
M7010KB01 .................................. 57
M7010KC01 .................................. 57
M7010KD01 .................................. 57
M7010KE01 .................................. 57
M7010L01 .................................... 57
M7010-V001 ................................ 57
M7010-V010 ................................ 57
M7020-V001 .................................. 6
M7030 .......................................... 56
M7030B03 .................................... 56
M7030B09 .................................... 56
M7030B11 .................................... 56
M7030C01 .................................... 56
M7030D07 .................................... 56
M7030DXX .................................... 56
M7030E01 .................................... 56
M7030F01 .................................... 56
M7030KB01 .................................. 56
M7030KD01 .................................. 56
M7030KE01 .................................. 56
M7030L01 .................................... 56
M7030-V001 ................................ 56
Made in Germany
Article Number Index
M7030-V002 ................................. 56
M7030-V003 ................................. 56
M7030-V005 ................................. 56
M704B .......................................... 59
M712C .......................................... 54
M712D .......................................... 54
M816A .......................................... 40
M830P .......................................... 42
M830R .......................................... 42
M830S .......................................... 42
M830V .......................................... 42
M830W ......................................... 42
U
U1281-V001 .................................. 90
U1281-V002 .................................. 90
U1289-V001 .................................. 90
U1289-V002 .................................. 90
U1289-V003 .................................. 90
U1381-V001 .................................. 90
U1381-V002 .................................. 90
U1387-V001 .................................. 90
U1387-V002 .................................. 90
U1387-V003 .................................. 90
U1387-V004 .................................. 90
U1389-V001 .................................. 90
U1389-V002 .................................. 90
U1389-V003 .................................. 90
U1389-V004 .................................. 90
U389A ........................................... 90
U389B ........................................... 90
Z
Z102A ........................................... 32
Z102C ........................................... 32
Z104A ..................................... 19, 27
Z104B ..................................... 19, 27
Z104C ........................................... 11
Z108A ........................................... 33
Z109A ........................................... 27
Z109B ........................................... 27
Z109C ........................................... 27
Z109D ........................................... 27
Z109E ........................................... 27
Z109F ........................................... 27
Z109G ........................................... 27
Z109H ........................................... 27
Z109I ............................................ 27
Z109J ........................................... 27
Z109K ........................................... 27
Z109L ..................................... 11, 27
Z110A ........................................... 19
Z110H ........................................... 34
Z110I ............................................ 21
Z110J ........................................... 34
Z110K ........................................... 34
Z112A ...........................................33
Z113A .....................................22, 27
Z113B ...........................................27
Z115A ...........................................27
Z201A .....................................30, 41
Z202A .....................................30, 41
Z203A .....................................30, 41
Z205B ...........................................30
Z205C ...........................................30
Z206B ...........................................22
Z206D ...........................................21
Z206E ...........................................21
Z207A .....................................31, 41
Z207B .....................................31, 41
Z207C .....................................31, 41
Z207D .....................................31, 41
Z208A ...........................................30
Z208B .....................................30, 41
Z211A ...........................................37
Z211C ...........................................37
Z211F ............................................37
Z211G ...........................................11
Z213B .....................................30, 41
Z215A ...........................................35
Z216A ...........................................35
Z216B ...........................................35
Z216C ...........................................11
Z217B ...........................................34
Z218A .....................................34, 70
Z218F ............................................34
Z218G ...........................................11
Z219A ...........................................30
Z219B ...........................................30
Z219C ...............................30, 57, 60
Z219D ...........................................30
Z225A ...............................30, 41, 49
Z227A ...........................................34
Z228A ...........................................33
Z229A .....................................15, 26
Z231A ...........................................22
Z231B ...........................................22
Z231C ...........................................22
Z231D .....................................22, 23
Z236A ...........................................23
Z236B ...........................................23
Z236C ...........................................23
Z236E .....................................22, 23
Z500A .....................................70, 71
Z501A .....................................49, 72
Z501B ...........................................49
Z501C ...........................................23
Z501D ...............................23, 49, 67
Z501E ...........................................49
Z501G ...........................................49
Z501J ................................48, 67, 73
Z501L ................................48, 53, 73
Z504A ............................................53
Z504C ...........................................53
Z504D ...........................................53
Z504E ............................................53
Z504F ............................................53
Z504G ...........................................53
Z504H ...........................................53
Z504J ......................................49, 74
Z504K ......................................49, 74
Z504L ..................................7, 57, 74
Z521A ............................................50
Z521B ............................................50
Z521C ...........................................50
Z523A ......................................47, 49
Z530E ............................................77
Z530K ............................................77
Z530S ............................................77
Z530T ............................................77
Z530X ............................................77
Z531C ...........................................77
Z531D ...........................................77
Z531M ...........................................77
Z531N ...........................................77
Z532A ............................................53
Z541A ............................................47
Z541C .....................................50, 67
Z541D ...........................................50
Z541F ............................................62
Z580A ............................................65
Z580B ......................................64, 65
Z580C ...........................................65
Z580D ...........................................65
Z590A ............................................69
Z590B ............................................69
Z600B ................................55, 60, 79
Z610A ............................................78
Z610C ...........................................78
Z610E ............................................78
Z610G ...........................................78
Z610H ...........................................78
Z610I .............................................78
Z610K ............................................78
Z610M ...........................................78
Z610N ...........................................78
Z610O ...........................................78
Z610P ............................................78
Z610Q ...........................................78
Z610R ............................................78
Z610T ............................................78
Z610U ............................................78
Z610V ............................................78
Z610W ...........................................78
Z610X ............................................78
Z610Y ............................................78
Z610Z ........................................... 78
Z611A ........................................... 78
Z611B ........................................... 78
Z611C ........................................... 78
Z611D ........................................... 78
Z611F ........................................... 78
Z611H ........................................... 78
Z611I ............................................ 78
Z611K ........................................... 78
Z700D ......... 7, 49, 53, 57, 64, 65, 74
Z700E ............................................. 7
Z710J ........................................... 23
Z710Q ........................................... 23
Z713C ........................................... 76
Z714A ........................................... 76
Z714B ........................................... 76
Z714C ........................................... 76
Z714D ........................................... 76
Z715A ................................. 7, 54, 60
Z7160 ............................................. 7
Z721D ....................................... 7, 73
Z722D ....................................... 7, 73
Z722E ....................................... 7, 73
Z723A ........................................... 72
Z740B ........................................... 54
Z745A ..................................... 55, 59
Z745D ........................................... 60
Z745G ........................... 7, 54, 55, 61
Z745K ..................................... 60, 76
Z745L ........................................... 61
Z745M .................................... 64, 71
Z745S ........................................... 61
Z745T ........................................... 61
Z750A ............................................. 7
Z750B ............................................. 7
Z751A ............................................. 7
Z751B ............................................. 7
Z751C ............................................. 7
Z752A ............................................. 6
Z752B ............................................. 6
Z753A ............................................. 7
Z753B ............................................. 7
Z821B ........................................... 41
Z824A ........................................... 41
Z852D ........................................... 44
Z852F ........................................... 44
Z860A ........................................... 41
Z861A ........................................... 41
Z862A ........................................... 41
Z863A ........................................... 41
Z863D ........................................... 43
Z863E ........................................... 43
Z863G ........................................... 43
Z864A ........................................... 57
Z864C ........................................... 43
General Notes
Terms and Conditions of Sale and Delivery
The “general terms and conditions of delivery for electrical industry products and services”
apply, including the supplement regarding extended reservation of proprietary rights, in its
respectively most up-to-date revision.
Subject to change without notice. Errors excepted.
Prices
Specified prices are valid for Germany as of 1 January 2006.
All prices are specified in Euros. They represent non-binding recommended prices ex
factory not including packaging.
Respectively applicable value added tax is invoiced as a separate item.
Prices and standard equipment included with instruments or components do not include
project engineering, programming, initial start-up or the like.
Prices are subject to change without notice. The currently valid price on the day on which
Made in Germany
delivery takes place shall be invoiced.
The minimum net order value is 100.00 Euros. A surcharge of 20.00 Euros will be added
to orders amounting to less than the minimum net order value.
Order Information
Please enter complete, unequivocal order information in order to avoid unnecessary
enquiries and misunderstandings during the course of order processing.
Devices and components can be ordered either by entering the designation and
description in plain text, or by entering the article number and all required features.
Export and Customs Documentation
One service charge will be invoiced per document for shipping instructions which deviate
from normal shipping conditions within the federal Republic of Germany, for example
preparation of certificates of origin, issuance of delivery notes in foreign languages,
preparation of export declarations etc.
97
http://www.gossenmetrawatt.com
Visit our website at
Product Spectrum
Measuring Technology –
Universal
Voltage Quality – Energy – Power
Field Measuring Systems, Cable Detection Devices
Resistance Thermometers / Clip-On Measuring Instruments
Digital Multimeters
Analog Multimeters
Multimeter Accessories
Calibrators
Temperature Measuring Instruments
Testing Technology –
Electrical
Testing Electrical Installations and Equipment (perm. installed)
Testing Electrical Devices (portable)
Testing Electrical Machinery
Earthing, Insulation, Low-Resistance
Workshop Test Panels
AS Interface Test Instruments
Power Supplies
Laboratory Power Supplies
Electronic Loads
Customer-Specific OEM Power Supplies
Software for
Measuring Instruments
Test instruments
Power Supplies
98
Made in Germany
Product Spectrum
Measuring Technology –
Industrial
Measuring Transducers for Temperature and DC Quantities
Measuring Transducers for Heavy Current Quantities
Measuring Transducers for Angle of Rotation and Position
DC Signal Isolators, Isolating Transformers
Power Packs, Mounting Racks
Isolating Switch Amplifiers, Isolating Amplifiers
Valve Control Modules, Limit Value Indicators
Thermocouples, Resistance Thermometers
Ex-i Equipment
Energy Management
Energy Meters, Summators, Additional Components
Power - Energy - Voltage Quality - Load Optimizing
ECS – Energy Control System
Energy Management – Engineering
Competent Project Management Partner
Control Technology
Analog Controllers, Compact Controllers
Controller Modules/OEM Control Systems
Complete Solutions for Machinery Manufacturing
Recording Technology
Display Recorders
Continuous Line Recorder
Point Recorders
Software for
ECS – Energy Control System
Measuring Transducers, Isolating Amplifiers
Controllers
Made in Germany
99
GMC-I Gossen-Metrawatt GmbH
Thomas-Mann-Str. 16 - 20
90471 Nürnberg, Germany
Phone: +49 (0) 9 11 86 02-111
Fax:
+49 (0) 9 11 86 02-777
e-mail: [email protected]
www.gossenmetrawatt.com
Printed in Germany · Subject to change without notice · 1/2.06 · Order no. 3-337-026-03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement