This busstop® station takes in up to twelve discrete three-wire inputs or six discrete four-wire input points per node. There are two dual output connectors. “T” Type Aux Power 4 Aux Powered Outputs “2G” Type (C0, C4) 12 DeviceNet Powered Inputs “2P” Type (C1-C3, C5-C7) There are two inputs per connector-one on pin four and one on pin two. Each input connector produces four bits of data- two input state bits, one short-circuit status bit and one open-circuit status bit. The state bit C5 is set when the discrete input device closes. The LED at each input point turns green when the input is one. Each input pair is monitored for short-circuits and open-circuits. Open-circuit detection can be C6 enabled for each input pair using a software configuration tool. The status bits automatically reset when the fault is removed. C4 C0 C1 C2 C3 C7 There are two outputs per connector-one on pin four and one on pin two. Each output connector consumes two output control bits and produces two output status bits-one control bit and one status bit for each output. The LED at each output point turns green when the output is on. Each output pair is monitored for short-circuits and opencircuits. Slave Address (0-99) 1 0 9 2 3 8 7 x10 4 5 6 1 0 9 2 8 3 7 4 5 6 x1 DeviceNet The node address and communication rate can be set using the rotary switches located under the device cover or through software node commissioning. The unit automatically detects the communication rate. The FDNP-P1204G-TT supports explicit messaging, poll, change of state, and cyclic I/O messages. These connections are established through UCMM or predefined master/slave connection set. FDNP-P1204G-TT • Advanced DeviceNet™ Station • 6 x 2 discrete inputs and 2 x 2 discrete Dimensions outputs 220.0 mm (8.66 in) Applications • For wet or dry environments • For use with twelve three-wire or six four- 42.0 mm (1.65 in) wire proximity and photoelectric sensors, and four discrete actuators Features • PNP short-circuit protected inputs with open-circuit protection • 0.5amp short-circuit protected outputs • Glass filled nylon with nickel plated brass • 210.0 mm (8.27 in) 5.3mm (.209in) 40.3 mm (1.59 in) connectors Rotary Address Switches 27.0 mm (1.06 in) 13.0 mm (0.51 in) Connectors DeviceNet Style: 5-Pin minifast® 1 = Shield 2=V+ 3=V4 = CAN_H 5 = CAN_L Cordset: Bus Line use RSM RKM 579- *M 3 4 5 2 2 1 1 Male Tee : Bus Line use RSM 2RKM 57 3 4 5 Female Through Bus InterlinkBT™ 3000 Campus Drive Minneapolis, MN 55441 Phone: (763) 694-2300 10240143 Rev. 2.0 11/01 1 Connectors Type “2P” 1= V +(A) 2 = Input B 3=V4 = Input A 5 = V +(B) Style: 5-Pin eurofast Cordset: Sensor with 2 Signals use RK 4.4T-*-RS 4.4T 3 (-) BU 4 ( ) BK 1 (+) BN 2 ( ) WH 5 Splitter: Splitter and 2 Sensors use VBRS 4.5-2RK 4T-*/*/S818 Sensor with 2 Signals Type “2G” 3 (-) BU 4 ( ) BK 1 (+) BN INPUT A 5 (+) GY 2 ( ) WH 3 (-) BU INPUT B Splitter and 2 Sensors 1 = N/C 2 = Output B (odd numbers) 3 = GND 4 = Output A (even numbers) 5 = PE Style: 5-Pin eurofast Cordset: Dual Ouput use RK 4.4T-*-RS 4.4T 3 (-) BU 4 ( ) BK Output A 2 ( ) WH 3 (-) BU Splitter: Dual Output or Dual Valve use VB2-RS 4.5T-*/2VAS 22-A528-*/*(“A”Style valve plug, other’s available) Output B Dual Output Field Wireable: Dual Output use BS 8141-0 Type “T” 1= Aux + 2= E+ 3= E4= Aux- Style: 4-Pin minifast® Cordset: Aux Power use RSM RKM 46- *M 1 3 3 1 2 4 4 2 Male Female Auxiliary Power Tee : Aux Power use RSM 2RKM 40 I/O Data Mapping Item Number/EDS File: F0062/I0062_xx.eds Product Code: 7/993 (3E1 hex) Input Data Output Data Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 0 I-7 I-6 I-5 I-4 I-3 I-2 I-1 I-0 1 - APS - - I-11 I-10 I-9 I-8 ISS-0 2 ISS-7 ISS-6 ISS-5 ISS-4 ISS-3 ISS-2 ISS-1 3 Bit 0 ISS-0 IOS-7 OSS-3 IOS-6 OSS-2 IOS-5 OSS-1 IOS-4 OSS-0IOS-3 ISS-11IOS-2 ISS-10IOS-1 ISS-9 IOS-0 ISS-8 4 IOS-7 IOS-6 IOS-5 5 OOS-3 OOS-2 OOS-1 OOS-0 Bit 7 Bit 6 Bit 5 - - Byte 0 - IOS-4 IOS-3 IOS-2 IOS-1 IOS-0 IOS-11 IOS-10 IOS-9 IOS-8 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 - O-3 O-2 O-1 O-0 Abbreviations I = Input Data (0=OFF, 1=ON) O = Output Data (0=OFF, 1=ON) ISS = Input Short Status (0=Working, 1=Fault) OS = Output Status (0=Working, 1=Fault) IOS = Input Open Status (0=Working, 1=Fault) OGS = Output Group Status (0=Working, 1=Fault) IGS = Input Group Status (0=Working, 1=Fault) APS = Aux Power Status (0=OFF, 1=ON) InterlinkBT™ 3000 Campus Drive Minneapolis, MN 55441 Phone: (763) 694-2300 10240143 Rev. 2.0 11/01 2 Module Specifications FDNP-P1204G-TT 12 PNP Input and Four 0.5A Output, Per Point Diagnostic Supply Voltage Bus power Internal current consumption Auxiliary power 11-26 VDC <100 mA, plus sum of sensor currents (from bus power) 18-26 VDC Input Circuits Input voltage (V+) Open circuit current (V+) Sensor current (V+) (12) PNP 3-wire sensors or dry contacts or (6) PNP 4-wire sensors 11-26 VDC (from bus power) < 1mA <80 mA per input Input signal current (Input) Input delay OFF <2mA ON 3.0-3.4 mA at 24VDC 2.5 ms Output Circuits Output voltage Output load current Open circuit current Maximum switching frequency (4) DC actuators 18-26 VDC (from auxiliary power) 0.5 A per output (from auxiliary power) < 1 mA per output 100 HZ I/O LED Indications Amber=Open-circuit Off=Off Green=On Red=Short-circuit Module Status LED Green: working properly Flashing green: detecting autobaud rate Flashing red: I/O short-circuit Network Status LED Green: established connection Flashing Green: ready for connection Flashing red: connection time-out Red: connection not possible Adjustments Address Communication Rate via Rotary Switch 0-63 Auto/125k/250k/500k Housing Material Enclosure Operating temperature glass filled nylon with nickel plated brass connectors NEMA 1,3,4,12,13 and IEC IP 67 -25° to 70°C (-13° to 158°F) InterlinkBT™ 3000 Campus Drive Minneapolis, MN 55441 Phone: (763) 694-2300 10240143 Rev. 2.0 11/01 3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement