Spectroscopy - TLS | Te Lintelo Systems

Spectroscopy - TLS | Te Lintelo Systems
www.zolix.com.cn
Spectroscopy
Instruments
Zolix Instruments Co.,Ltd..
Philosophy
Growth Together, Success Forever
Objective
World-Class Photonic Products & Systems Provider
About Zolix
Zolix Instruments CO., LTD (Zolix) is located in Beijing, the capital of China and designs
spectrographs, light sources, detectors, optical components and optics-based solutions
for the scientific research. We are proud of partnering with our customers to solve their
most challenging problems in professional, unique, innovative ways
Established in 1999, Zolix has over many years of knowledge and expertise with broad
range of technologies allowing the company to continually deliver innovative products in
the areas of photonics instrumentation, optical components etc. In addition, Zolix has
professional experience of partnering with OEM customers, delivering solutions including
design, testing and manufacturing.
About products
Zolix has strong core technologies with patent in scientific instruments. Many technical
engineers engaged in the R&D and production, kinds of successful international
cooperation cases. The powerful technical strength ensures the possibility to serve the
customers complete solutions.
Certificates
Zolix is ISO9001, LVD, CE, RoSH certified
The Zolix employees & Distributors all over the
world, are looking forward to working with you and
providing the best scientific solution for your needs !
Table of Contents
2
Spectroscopy Instruments
37
Light Sources
3
Omni Spectrographs
38
13
Detectors
Xenon Light Sources and
Tungsten-halogen Light Sources
21
Data Acquisition Systems
43
Tunable Monochromatic Light Source
28
Software
47
Light Source Accessories
30
Sample Chambers
50
Light Sources for Spectroscopy
33
Accessories for SAC series product
34
Motorized Filter Wheels
35
Fiber Adapters
52
Application Solutions
53
Fluorescence/Photoluminescence
56
Raman Spectroscopy
58
Absorbance, Transmittance and Reflectance
60
Emission Spectroscopy
61
Detector Spectral Responsivity Measurement
63
Solar Cell Testing & Characterization
66
Solar Simulator
67
Photocatalysis
Detectors
Spectroscopy Instruments
Spectroscopy instruments include Spectrographs, Monochromators, Light Source and Components, detectors, data
collection systems, sample chamber, motorized filter wheel, motorized slit, fiber and fiber adapter.
3
3
7
8
9
13
14
16
17
18
19
20
20
21
22
22
23
23
2
Omni Spectrographs
Omni-Ȝ Monochromators and Spectrographs
Omni-ȜxxxD Double Monochromators/Spectrographs
Gratings
Dispersion and Wavelength Coverage
Detectors
PMTH-S1-(x) Detectors
DSi200/300 Silicon Detectors
DInGaAs Detectors
TE cooled DInGaAs Detectors
Pbs Detectors
InAs Detectors
Pre-amplifier
Data Acquisition Systems
Digital Lock-In Amplifier
DCS500PA high performance I/V amplifier
Optical Chopper
DCS540 optical chopper system
24
24
24
25
Data Acquisition Systems
DCS103 Data Acquisition System
DCS300PA Data Acquisition System
Photon Counting Units
25
26
27
DCS202PC series
DCS210PC
Systenm Diagram
28
Software
30
Sample Chambers
30
31
32
32
SAC three-port sample chamber
SAC-PL compact PL sample chamber
SAC-Fluo fluorescence sample chamber
SAC-RF total reflection sample chamber
33
Accessories for SAC series product
34
Motorized Filter Wheels
35
Fiber Adapters
Spectroscopy Instruments
Omni Spectrographs
Omni-Ȝ Monochromators and Spectrographs
Omni-Ȝ Series of imaging spectrographs and monochromators from Zolix
Instruments are profession standard for researchers who demand the
highest quality data. Zolix spectrographs and monochromators feature a
very flexible design that can be configured for a wide range of applications
& spectral range from UV to NIR.
200mm, 320 mm,500 mm,750 mm focal length
ȋ
Our rugged Czerny-Turner spectrographs come pre-aligned and precalibrated for ease of operation.
ȋ
Interchangeable triple grating turret– Different wavelength ranges and
resolutions, Provide a simple, accurate and convenient way for the user
to change gratings within the spectrograph unit
ȋ
These instruments can be integrated with single point detectors, InGaAs
cameras and CCDs to offer a versatile, most sensitive modular solution
for different applications ;
ȋ
Accessories including filter wheels, fiber adapters, shutters, motorized
slits, sample chambers etc.
ȋ
Software can complete data acquisition for detectors including single
point detectors and CCD.
ȋ
Labview driver for programming to operate Omni-Ȝ Series spectrographs
and monochromators.
Omni spectrographs
ȋ
Omni-Ȝ Specifications(@1200g/mm* )
ȟ
Omni-Ȝ200i
Omni-Ȝ300i
Omni-Ȝ500i
Omni-Ȝ750i
Focal Length (mm)
200
320
500
750
Aperture Ratios
f/3.5
f/4.2
f/6.5
f/9.7
Resolution(nm)-PMT*
0.15
0.08
0.046
0.028
Resolution(nm)-CCD(26μm) *
0.28
0.174
0.15
0.09
Dispersion (nm/mm) *
3.6
2.3
1.7
1.1
Wavelength Accuracy(nm)
±0.2
±0.2
±0.15
±0.1
Wavelength Repeatability (nm)
±0.1
±0.1
±0.08
±0.01
Step (nm)
0.01
0.005
0.005
0.0025
Stray Light
1×10-5
1×10-5
1×10-5
1×10-5
Focal Plane Size (mm)
30(w)×14(h)
30(w)×14(h)
30(w)×14(h)
30(w)×14(h)
Optical Axis Height(mm)
146
146
146
146
Slit
Width: 0.01-3mm(Motorised or manual slit), Height: 2Ƞ4喑14 mm, height selectable
Grating Size(mm)
50×50
68×68
68×68
68×68
Grating Mount
Dual grating turret
Interchangeable triple
grating turret
Interchangeable triple
grating turret
Interchangeable triple
grating turret
Computer Interface
USB2.0
USB2.0 and RS232
USB2.0 and RS232
USB2.0 and RS232
Size (mm)
300×216×213
420*295*232
550*288*220
800*338*218
Weight (Kg)
14
16
22
32.5
ȋ
Dispersion measured with 1200g/mm grating @ 435.8nm
ȋ
PMT resolution measured with 1200g/mm @ 435.8nm, 10um slit width and 4mm slit height
ȋ
CCD resolution measured with 1200g/mm @ 435.8nm, 10um slit width and 26um pixel
+86 10 56370168 www.zolix.com.cn
3
Spectroscopy Instruments
Omni-Ȝ spectrographs named views
Omni-ȜXX Y Z(i)
Omni spectrographs
20: 200 mm focal length
30: 320 mm focal length
50: 500 mm focal length
75: 750 mm focal length
3: Slit front exit, CCD side exit
4: Dual CCD exits
5: Slit front exit
6: CCD front exit
7: Dual slit exits
8: CCD front exit, slit side exit
9: Slit side exit
0: Standard (Side entrance,
protected Al coated grating
and mirror)
1: IR (Protected gold coated)
2: Dual slit entrances
3: IR & Dual slit entrances
4: UV
5: UV & Dual slit entrances
6: Protected silver coated
7: Protected silver coated &
Dual slit entrances
e.g Omni-Ȝ3047, side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, UV monochromator.
Optical Configuration
Omni-Ȝ200i Monochromator/Spectrograph
Omni-Ȝ2002i
2P
2PQL
2PQL
Omni-Ȝ2003i
Omni-Ȝ2007i
Omni-Ȝ2005i
Omni-Ȝ300i Monochromator/Spectrograph
2
Omni-Ȝ3005i
Omni-Ȝ3006i
Omni-Ȝ3007i
Omni-Ȝ3008i
Omni-Ȝ500i Monochromator/Spectrograph
2PQL¬
2PQL¬
Omni-Ȝ5005i
4
+86 10 56370168 www.zolix.com.cn
Omni-Ȝ5006i
Omni-Ȝ5007i
Omni-Ȝ5008i
Spectroscopy Instruments
Omni-Ȝ750i Monochromator/ Spectrograph
Omni-Ȝ7505i
2PQL¬L
Omni-Ȝ7506i
Note: the second entrance
is the optional (blue).
Omni-Ȝ7507i
Omni-Ȝ7508i
Omni-Ȝ Selections
Omni spectrographs
2PQL¬L
Model
Description
Omni-Ȝ200i series Monochromator(200 mm focal length, support 2 gratings simultaneously)
Omni-Ȝ2003i
side entrance, slit front exit,CCD side exit,support 2 gratings simultaneously
Omni-Ȝ2002i
side entrance, CCD side exit,support 2 gratings simultaneously
Omni-Ȝ2005i
side entrance, slit front exit, support 2 gratings simultaneously
Omni-Ȝ2007i
side entrance, slit front exit, slit side exit, support 2 gratings simultaneously
Omni-Ȝ300i series Monochromator/ spectrograph(320 mm focal length, support 3 gratings simultaneously)
Omni-Ȝ3005i
side entrance, slit front exit, support 3 gratings simultaneously
Omni-Ȝ3007i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ3008i
side entrance, CCD front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ3004i
side entrance, CCD front exit, CCD side exit, support 3 gratings simultaneously
Omni-Ȝ3015i
side entrance, slit front exit, support 3 gratings simultaneously, IR monochromator,
Omni-Ȝ3017i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, IR monochromator
Omni-Ȝ3027i
Dual entrances, slit front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ3028i
Dual entrances, CCD front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ3024i
Dual entrances, CCD front exit, CCD side exit, support 3 gratings simultaneously
Omni-Ȝ3047i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ3048i
side entrance, CCD front exit, slit side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ3044i
side entrance, CCD front exit, CCD side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ500i series Monochromator/ spectrograph (500 mm focal length, support 3 gratings simultaneously)
Omni-Ȝ5005i
side entrance, slit front exit, support 3 gratings simultaneously
Omni-Ȝ5007i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ5008i
side entrance, CCD front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ5004i
side entrance, CCD front exit, CCD side exit, support 3 gratings simultaneously
Omni-Ȝ5015i
side entrance, slit front exit, support 3 gratings simultaneously, IR monochromator,
Omni-Ȝ5017i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, IR monochromator
Omni-Ȝ5027i
Dual entrances, slit front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ5028i
Dual entrances, CCD front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ5024i
Dual entrances, CCD front exit, CCD side exit, support 3 gratings simultaneously
Omni-Ȝ5047i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ5048i
side entrance, CCD front exit, slit side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ5044i
side entrance, CCD front exit, CCD side exit, support 3 gratings simultaneously, UV monochromator
Omni-Ȝ750 series Monochromator/ spectrograph (750 mm focal length, support 3 gratings simultaneously)
Omni-Ȝ7505i
side entrance, slit front exit, support 3 gratings simultaneously
Omni-Ȝ7507i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ7508i
side entrance, CCD front exit, slit side exit, support 3 gratings simultaneously
Omni-Ȝ7504i
side entrance, CCD front exit, CCD side exit, support 3 gratings simultaneously
Omni-Ȝ7515i
side entrance, slit front exit, support 3 gratings simultaneously, IR monochromator,
Omni-Ȝ7517i
side entrance, slit front exit, slit side exit, support 3 gratings simultaneously, IR monochromator
+86 10 56370168 www.zolix.com.cn
5
Spectroscopy Instruments
Omni-Ȝ Drawings
Omni-Ȝ300i Monochromator/Spectrograph
Omni-Ȝ500i Monochromator/Spectrograph
Omni-Ȝ750i Monochromator/Spectrograph
Omni spectrographs
Omni-Ȝ200i Monochromator/Spectrograph
6
+86 10 56370168 www.zolix.com.cn
Spectroscopy Instruments
Omni-ȜxxxD Double Monochromators/Spectrographs
The Double Monochromators/Spectrographs include two 320mm
focus monochromators( or 500 mm, 750 mm focus) which are
with fine alignment. Double Monochromator has the dispersion
subtraction mode and dispersion sum mode. Using dispersion
sum mode, the double monochromator/spectrograph spectral
resolution can be doubled, suitable for high resolution measurement.
Using dispersion subtraction mode, the double monochromator/
weaker signal detection, such as Raman spectral measurement.
Please contact us if you need specification !
Omni spectrographs
spectrograph stray light can be reduced effectively, suitable for
Grating Curves
150 g/mm-Ruled
600 g/mm-Ruled
300 g/mm-Ruled
1200 g/mm-Ruled and Holographic
+86 10 56370168 www.zolix.com.cn
7
Spectroscopy Instruments
Gratings
The green models are used commonly as we suggested
Model
Range(nm)
Grooves(g/mm)
Blaze(nm)
Size(mm)
180-400
250-600
190-600
300-720
350-800
190-800
190-800
400-1200
3600
2400
2400
2000
1800
1800
1201.6
1200
300
300
250
475
500
250
250
700
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
190-600
250-600
300-800
350-800
200-500
200-600
200-1000
350-1100
500-1200
350-1600
700-1700
200-600
330-1000
500-1500
650-2200
800-2400
1-2.4 μm
2400
2400
1800
1800
1200
1200
1200
1200
1200
900
830
600
600
600
600
600
600
300
300
300
300
300
300
300
150
150
150
150
150
150
150
150
75
75
75
50
240
300
400
500
250
300
400
500
750
550
1200
300
500
750
1.0 μm
1.2 μm
1.6 μm
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
68 x 68
Holographic
1-360-180-500-NP
1-240-250-600-NP
1-240-190-800-NP
Omni spectrographs
1-200-300-900-NP
1-180-350-900-NP
1-180-190-900-NP
1-120-190-800-NP
1-120-400-1200-NP
Ruled
1-240-240-NP
1-240-300-NP
1-180-400-NP
1-180-500-NP
1-120-250-NP
1-120-300-NP
1-120-400-NP
1-120-500-NP
1-120-750-NP
1-090-550-NP
1-083-1200-NP
1-060-300-NP
1-060-500-NP
1-060-750-NP
1-060-1000-NP
1-060-1200-NP
1-060-1600-NP
1-030-300-NP
1-030-500-NP
1-030-760-NP
1-030-1000-NP
1-030-1200-NP
1-030-2000-NP
1-030-3000-NP
1-015-300-NP
1-015-500-NP
1-015-800-NP
1-015-1000-NP
1-015-1250-NP
1-015-2000-NP
1-015-3000-NP
1-015-4000-NP
1-0075-8000-NP
1-0075-10000-NP
1-0075-12000-NP
1-0050-12000-NP
8
200-600
300-1000
450-1500
600-2000
800-2200
1.4-4 μm
2-4.8 μm
200-600
330-1100
400-1600
600-2000
800-2500
1.1-4 μm
2.2-4 μm
2.5-8 μm
6-16 μm
6-18 μm
9-20 μm
8-22 μm
+86 10 56370168 www.zolix.com.cn
300
500
760
1000
1200
2.0 μm
3.0 μm
300
500
800
1090
1250
2 μm
3 μm
4 μm
8 μm
10 μm
12.0 μm
12 μm
Spectroscopy Instruments
Dispersion and Wavelength Coverage
Dispersion (nm/
mm)
Spectrometer
Mechanical Range
(nm)
CCD Resolution
with 13.5um pixels
(nm)
PMT Resolution
(nm)
Spectral Coverage
with 30mm CCD
(nm)
3600
1
0 to 400
0.1
0.05
30
2400
1.4
0 to 600
0.14
0.08
42
1800
2.16
0 to 800
0.2
0.1
64
Omni-Ȝ200i
1200
3.6
0 to 1200
0.28
0.15
108
900
4.96
0 to 1600
0.4
0.2
148
600
7.68
0 to 2400
0.56
0.3
230
300
15.77
0 to 4800
1.12
0.6
473
150
31.89
0 to 9600
2.24
1.2
956
3600
0.66
0 to 400
0.058
0.03
20
2400
0.91
0 to 600
0.087
0.04
27
1800
1.39
0 to 800
0.116
0.05
42
Omni-Ȝ300i
1200
2.28
0 to 1200
0.174
0.08
68
900
3.16
0 to 1600
0.232
0.11
95
600
4.87
0 to 2400
0.348
0.16
146
300
9.97
0 to 4800
0.696
0.32
299
150
20.13
0 to 9600
1.392
0.64
604
3600
0.43
0 to 400
0.033
0.02
13
2400
0.6
0 to 600
0.050
0.03
18
1800
0.91
0 to 800
0.067
0.04
27
Omni-Ȝ500i
1200
1.5
0 to 1200
0.100
0.05
45
900
2
0 to 1600
0.133
0.07
60
600
3.15
0 to 2400
0.200
0.10
95
300
6.43
0 to 4800
0.400
0.20
193
150
12.97
0 to 9600
0.800
0.40
389
3600
0.3
0 to 400
0.022
0.01
9
2400
0.43
0 to 600
0.034
0.02
13
1800
0.64
0 to 800
0.045
0.02
19
Omni-Ȝ750i
1200
1
0 to 1200
0.067
0.03
30
900
1.4
0 to 1600
0.089
0.04
42
600
2.14
0 to 2400
0.134
0.06
64
300
4.36
0 to 4800
0.268
0.12
131
150
8.77
0 to 9600
0.536
0.24
263
Omni spectrographs
Grating (g/mm)
ƾ
Model
"Ț Center Wavelength of 253.65 nm used with 3600 g/mm grating Center Wavelength of 435.833 nm used with all other gratings Dispersion
may vary at different wavelengths"
ț Spectral range will depend not only on Mechanical Range, but also the grating Blaze Wavelength
ȑ Listed Resolution values are not at the same wavelength, the specified wavelength is close to blaze wavelength
+86 10 56370168 www.zolix.com.cn
9
Spectroscopy Instruments
Omni-Ȝ200i Input Port
Omni-Ȝ200i
Side input port
Spacer(Standard)
Filter Wheel
Omni spectrographs
SD25-R
3mm Manual Slit
3mm Motorized Slit
15mm Motorized Slit
ESLIT
EMSLIT
EMWSLIT
(Standard)
BFC-441
Sample Chamber
SAC
SAC-FLUO
BFC-442
BFC-443
BFC-447
Fiber
Omni-Ȝ200i Output Port
Omni-Ȝ200i
Side/ Front output port(slit)
3mm Manual Slit
3mm Motorized Slit
15mm Motorized Slit
ESLIT
OMSLIT
OMWSLIT
(Standard)
Sample Chamber
SAC
SAC-FLUO
Fiber Adapter
BFC-441
BFC-442
BFC-443
BFC-447
Fiber
10
+86 10 56370168 www.zolix.com.cn
PMT Series
HVC1800
DCS210PC
Si Detector
InGaAs Detector
PbS Detector
InAs Detector
DCS300PA
Spectroscopy Instruments
Omni-Ȝ300i/500i/750i Input Port
Omni-Ȝ300i/500i/750i
Side input port
Filter Wheel
Spacer(Standard
SD25
3mm Motorized Slit
15mm Motorized Slit
ESLIT
EMSLIT
EMWSLIT
(Standard)
Omni spectrographs
3mm Manual Slit
Fiber Adapter
BFC-441 BFC-442
BFC-443 BFC-447
Sample Chamber
SAC
SAC-FLUO
Fiber
Omni-Ȝ300i/500i/750i
Front input port
3mm Manual Slit
3mm Motorized Slit
15mm Motorized Slit
ESLIT
EMSLIT
EMWSLIT
(Standard)
Fiber Adapter
BFC-441
BFC-442
BFC-443
BFC-447
Sample Chamber(Only for Omni-Ȝ 500i/750i)*
SAC
SAC-FLUO
Fiber
+86 10 56370168 www.zolix.com.cn
11
Spectroscopy Instruments
Omni-Ȝ300i/500i/750i Output Port
Omni-Ȝ300i/500i/750i
Front/Side output port(CCD / slit)
3mm Manual Slit
3mm Motorized Slit
d
15mm Motorized
ESLIT
OMSLIT
Slit
OMWSLIT
Omni spectrographs
(Standard)
Sample Chamber
SAC
SAC-FLUO
Fiber Adapter
BFC-441
BFC-442
BFC-443
BFC-447
Fiber
12
+86 10 56370168 www.zolix.com.cn
CCD
Flanges
C
PMT Series
HVC1800
DCS210PC
Si Detector
InGaAs Detector
PbS Detector
InAs Detector
DCS300PA
Spectroscopy Instruments
Detectors
Zolix offers a range of single channel detector (PMT and solid detectors) which can be connected well with Zolix
monochromator and accessories for spectrometers, spectral coverage is UV-VIS-IR spectrum.
ȋ
Room temperature PMT, spectral range: 200nm-900nm (1010nm, 1200nm)
ȋ
UV-enhanced, high sensitivity Si photodetector, spectral range: 200-1100nm
ȋ
Room temperature, TE cooled InGaAs IR detectors, spectral range: 0.8-2.6μm
ȋ
Room temperature PbS IR detectors, spectral range: 0.8-3.2μm
ȋ
Room temperature, TE cooled InAs IR detectors, spectral range: 1-3.8μm
ȋ
Liquid nitrogen cooled InSb IR detectors, spectral range: 1-5.5μm
ȋ
ȋ
Detectors
ȋ
Liquid nitrogen cooled, high speed response InSb IR detectors, pre-amplifier, response time:<25ns, spectral
range: 1-5.5μm.
TE cooled, liquid nitrogen cooled HgCdTe mid and far IR detectors, spectral range: 1-5.5μm
Liquid nitrogen cooled, high speed response HgCdTe mid and far IR detectors, pre-amplifier, response
time:<50ns, spectral range:1-12μm
UV
VIS
NIR
IR
PMT
Si
InGaAs
PbS
InAs
InSb
MCT
WaveLengthnm
Detector Selections
PMTH-S1-xx
Si
InGaAs
PbS3200
InAs
185-900
8*24
Room temperature
Current
HVC1800(HV power
supply)
200-1100
ø11.28
Room temperature
Current
800-2600
ø3
-40Ď TE
Current
800-3200
6*6
Room temperature
Voltage
1000-3800
ø2
-40Ď TE
Current
Detector
Wavelength (nm)
Effective Area (mm)
Cooling
Mode
Note
ZTC
ZTC
+86 10 56370168 www.zolix.com.cn
13
Spectroscopy Instruments
Single Channel Detector
PMTH-S1-(x) Detectors
ȋ
Design to meet high sensitivity high measurement in the spectral
range: 200-1100nm
ȋ
Light tight integrating housing
ȋ
Matched to Omni-Ȝ series
ȋ
Wide range of accessories, including high voltage power supply
Detectors
Side window photomultipliers tubes
ȋ
Side window, with electromagnetic and optical shielding.
ȋ
Match well with Zolix spectrograph, sample chamber.
ȋ
Output signal through a standard BNC.
ȋ
Stable high-voltage input through a dedicated high pressure
resistance BNC.
ȋ
A variety of models side-windows photomultiplier tubes can be
built-in.
ȋ
Current output
ȋ
Voltage output as option
ȋ
Recommended with the high-voltage power supply.
Specifications:
ȟ
Spectral Response (nm)
Wavelength of Maximum Response (nm)
Cathode Sensitivity (wavelength, mA/W)
Dynode Gain
Cathode Luminous Sensitivity (μA/Lm)
Anode Luminous Sensitivity (A/Lm)
Anode Dark Current (Typ., nA)
Anode Dark Current (Max., nA)
Dark Count (Typ.,[email protected]Ď)
Dark Count (Max.,[email protected]Ď)
Photocathode Material
Effective Area (mm)
Dynode Structure
Anode Pulse Rise Time (ns)
Electron Transit Time (ns)
Supply Voltage between Anode and Cathode (V)
Supply Voltage between Anode and Last Dynode (V)
CR316-02
185-650
340
48
1.0×107
40
5
15
Sb-Cs
R1527
R1527P
CR131
CR131A
R928
185-680
185-900
400
400±30nm
60
74
6.7×106
1.0×107
60
140
250
400
1000
1500
2500
0.1
3
2
0.5
50
10
50
Dualalkali
Multialkali
8×24
Circular-cage, Number of Stages: 9
2.2
22
1250
250
R2949
185-900
400±30
68
Spectral response curve and quantum
CR316-02
1P28
14
+86 10 56370168 www.zolix.com.cn
R1527/R1527P
R1527/R1527P
CR131/CR131A/R928
CR131/CR131A/R928
R2949
R2949
200
2000
2
25
300
500
8×6
Spectroscopy Instruments
HVC1800 High Voltage Power Supply
High voltage power supply provides stable DC high voltage for the photomultiplier
tubes. With the HVC1800, the photomultiplier tubes are well suited for use in various
low-level photometries such as general single photon counting applications.
ȋ
ȋ
Output voltage: 0-1500 V, DC negative voltage.
Output voltage can be changed manually; also available through an external control
port (0-10 V) by PC, or D/A converter (such as DCS300PA).
Maximum Output Current: 0.5mA
ȋ
Maximum output voltage drift: d0.05%/h
ȋ
3 1/2 digits LED numeric display
ȋ
Size:240mmx240mmx120mm
ȋ
Weight:3.4kg
Detectors
ȋ
Selections
Model
Description
Signal Polarity
PMTH-S1-CR316-02
Photomultiplier tube (185-650nm)
Negative
PMTH-S1-R1527
Photomultiplier tube (185-670nm), high sensitivity,
current output mode (blue)
Negative
PMTH-S1-R1527P
Photomultiplier tube (185-670nm), high sensitivity, low
dark counts, current output mode (blue)
Negative
PMTH-S1-CR131
Photomultiplier tube (185-900nm), ordinary, current
output mode (red)
Negative
PMTH-S1-CR131A
Photomultiplier tube (185-900nm), high sensitivity,
current output mode (red)
Negative
PMTH-S1-R928
Photomultiplier tube (185-900nm), ordinary, current
output mode (red)
Negative
PMTH-S1-R2949
Photomultiplier tube (185-900nm), high sensitivity, low
dark counts, current output mode (red)
Negative
High Voltage Power Supply
Description
Output Voltage Polarity
HVC1800
High voltage power supply (0-1500 V)
Negative
+86 10 56370168 www.zolix.com.cn
15
Spectroscopy Instruments
DSi200/300 Silicon Detectors
Silicon photodiode detectors are a rugged standard detector for
applications that have good collected light levels.
DSi200 is UV enhanced for operation from 200-1100 nm, built-in UV
sensitive Si photodetector
ȋ
DSi300 is general purpose detector for 300-1100 nm
Detectors
ȋ
Both are enclosed in a housing with BNC signal
connector, and include mounting flanges for the
direct mounting on the slit assembly of Omni-Ȝ
Mode
series monochromators. I-V amplifier ZAMP is
DSi 300
UV enhanced
Blue enhanced
Effective Area(mm2)
100 ( ø11.28)
100 ( ø11.28)
recommended for the signal conversion
Spectral Range(nm)
200-1100
350-1100
Silicon photodetector application advices:
Peak Wavelength(nm)
820
970
Peak Responsivity(A/W)
0.52
0.60(0.55)
Response(A/W)
0.14(0.09)@254 nm 0.20(0.15)@410 nm
Rise Time(μs)
5.9
2
Operating Temperature(°C)
-10~+60
-10~+60
Storage Temperature(°C)
-20~+70
-20~+70
Shunt Resistor(Mȍ)
10 (5)
(10)
Noise Equivalent Power
NEP(W / ¥Hz)
4.5×10-13
2.0×10-13
Max.Operating
Current([email protected] Bias)
0.1
10.0
Junction Capacitance
([email protected] Bias)
4500
8800
Signal Output
current
current
Output Signal Polarity
P
P
ȋ
ȋ
ȋ
ȋ
16
DSi200
DSi200/DSi300 are both current output modes,
before connecting to the signal processors such
as oscilloscope or lock-in amplifier, the IV Transimpedance Amplifier ZAMP is proposed to be
connected as a preamp and which can convert the
current signal to voltage signal.
If the signal processor indicates that it can be input
current signal, you can connect the detectors to
the signal processors directly. In order to improve
the detection sensitivity, the IV Trans-impedance
Amplifier is recommended.
DSi200/DSi300 used with the DCS103 data
acquisition system, the IV Trans-impedance
Amplifier is recommended in order to improve the
detection sensitivity.
DSi200/DSi300 used with the DCS300PA data
acquisition system, as signal amplifier has been
integrated in the DCS300PA dual channel, it does
not need to match pre-amplifier.
+86 10 56370168 www.zolix.com.cn
Spectroscopy Instruments
DInGaAs Detectors
DInGaAs Detectors
DInGaAs series Detectors are room temperature, high performance.
InGaAs detectors operating over the NIR range from 0.8μm to
2.6μm. The two kinds of DInGaAs1700-R03M, DInGaAs2600-R03M
detectors have the same construction design.
Detectors
Specifications
Effective Area
Diameter(mm)
Spectral Range(nm)
Peak Responsivity
(A/W, Min.)
Dark Current(nA, Max.)
DInGaAs1700-R03M
DInGaAs2600-R03M
3
3
800-1700
800-2600
0.9
1.1
100
1000
12
4.1×1010
D* (typ.)
2.3×10
NEP (typ.)
1.2×10-13
6.5×10-12
Resistor(Mȍ)
1.5
320ȍ
Capacitance(pF)
800
9000
Rise Time(ns)
100
1μs
Signal Output
current
current
Output Signal Polarity
P
P
+86 10 56370168 www.zolix.com.cn
17
Spectroscopy Instruments
TE cooled DInGaAs Detectors
TE cooled InGaAs detectors, spectral range from 0.8μm to 2.6μm.
DInGaAs(x)-TE detectors have the same construction. DInGaAs
-1700-TE and DInGaAs-2600-TE both use two stage TE cooled
InGaAs detectors. Spectral response curve see below.
Figure 1. Responsivity vs. Wavelength for InGaAs @ 22°C
Responsivity (A/W)
Detectors
1.5
1
1.7μm
2.6μm
0.5
0
0.5
1
1.5
2
2.5
3
Wavelength (μm)
Specifications
DInGaAs1700-TE
In the cooled mode, the detectors must be working
Effective Area Diameter(mm) 3
3
with temperature controller (ZTC). Trans-impedance
Spectral Range喍nm喎
800-1700
800-2600
amplifier ZAMP is recommended
Peak Responsivity喍A/W喎
0.9
1.2
DInGaAs detectors application
ȋ
18
DInGaAs2600-TE
DInGaAs series and DInGaAs-TE series detectors
are current output mode, before connecting to the
signal processors such as oscilloscope or lock-in
amplifier, the IV Trans-impedance Amplifier ZAMP is
proposed to be connected as a pre-amp. and which
can convert the current signal to voltage signal. If the
signal processor indicates that it can be input current
signal, you can connect the detectors to the signal
processors directly. In order to improve the detection
sensitivity, the IV Trans- impedance Amplifier is
recommended.
ȋ
DInGaAs series and DInGaAs-TE series detectors
used with the DCS103 data acquisition system, the IV
Trans-impedance Amplifier is recommended in order
to improve the detection sensitivity.
ȋ
DInGaAs series and DInGaAs-TE series detectors used
with the DCS300PA data acquisition system, as signal
amplifier has been integrated in the DCS300PA dualchannel; it does not need to match a pre-amplifier.
ȋ
In the TE cooled mode, DInGaAs-TE series detectors
must work with Temperature controller (ZTC) for
cooling control.
+86 10 56370168 www.zolix.com.cn
13
D*(typ.)
8.4×10
4.9×1011
NEP(typ.)
3.2×10-15
5.5×10-13
Operating Temperature(Ď)
-40
-40
Temperature Stability(Ď)
±0.5
±0.5
Ambient Temperature(Ď)
+10~+40
+10~+40
Signal Output
current
current
Output Signal Polarity
P
P
Temperature Controller
ZTC
ZTC
Spectroscopy Instruments
PbS Detectors
Room temperature IR detectors, spectral range from 0.8 to 3.2μm.
DPbS2900 and DPbS3200 have the same construction (built-in preamplifier).
Detectors
Relative spectral response
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
Fig1
PbS detectors application
ȋ
ȋ
0%
0.8 1.1 1.4 1.7 2.0 2.3 2.6 2.9 3.2 3.5
DPbS2900 and DPbS3200 are the photoconductive
IR detectors, which must be used with lock-in
amplifier.
DPbS2900 and DPbS3200 detectors integrate the
pre-amplifier, the detectors output signals are voltage
signals. When working with DCS103 or DCS300PA,
the detectors needs choosing voltage signal as the
sampling mode.
Fig2
DPbS2900
DPbS3200
Effective Area Diameter(mm2)
4x5
6x6
Spectral Range(μm)
0.8-2.9
0.8-3.2
Peak Wavelength(μm)
≥2.2
≥2.1
Su(V/W)
≥ 3×10΀
≥ 300
0.2-2
0.1-0.3
Rd (Mȍ)
1/2
D* (cm(Hz) /W)
2
≥5× 10
≥1×102
Time Constant
Ō200
Ō400
Magnification
×1 ,×10 ,×100
×1 , ×10 , ×100
Input Offset Voltage(μV)
±1
±1
Pre-amplifier Input Drift(μV)
±1
±1
Frequency Response Range(Hz) 100-1000 (400 Hz recommended)
Signal Output
Voltage
Voltage
Output Signal Polarity
P
P
Note: Please refer to Fig1 for DPbS2900 and Fig2 for DPbS3200
+86 10 56370168 www.zolix.com.cn
19
Spectroscopy Instruments
InAs Detectors
High performance InAs Series Detectors
NIR detectors, spectral range from 1 to 3.8 μm.
Detectors
DInAs3800-TE built-in TE cooling detectors
InAs Detectors Application:
ȋ
ȋ
ȋ
ȋ
DInAs3800-TE detectors are current output mode, before
connecting to the signal processors such as oscilloscope or lockin amplifier, the IV Transimpedance Amplifier ZAMP is proposed to
be connected as a pre-amp. and which can be input current signal,
you can connect to detectors to the signal processors directly. In
order to improve the detection sensitivity, the IV Transimpedance
Amplifier is recommended.
DInGaAs3800-TE
Effective Area Diameter(mm)
2
Spectral Range(μm)
1-3.8
Peak Responsivity(A/W)
1.5
D* (@Ȝpeak,1KHz)cm Hz 1/2W-1
9.1×1012
NEP (@Ȝpeak,1KHz)pW/Hz 1/2
4.4
DInAs3800-TE detectors used with the DCS103 data acquisition
system, the IV Trans-impedance Amplifier is recommended in order
to improve the detection sensitivity
Operating Temperature(Ď)
-40
Temperature Stability(Ď)
±0.5
Signal Output
current
DInAs3800-TE detectors used with the DCS300PA data acquisition
system, as signal amplifier has been integrated in the DCS300PA
dual-channel; it does not need to match a pre-amplifier
Output Signal Polarity
P
Temperature Controller
ZTC
In the TE cooled mode, DInAs3800-TE detectors must work with
Temperature controller (ZTC) for cooling control
Pre-amplifier
Zolix offers a variety of low noise, high gain amplifier to working with the
single channel detectors. The amplifier is mainly used to convert detector
output signals, and amplify the signals. Then the signals are inputted to other
measurement equipments, such as data acquisition system, oscilloscopes,
DMM, to achieve weak signal measurement.
ZAMP-A is suitable for high impedance detectors.
Mode
Gain Range
Noise Voltage
Input Impedance
Output Impedance
Current Range
Output Voltage Range
Gain Accuracy
Size
20
+86 10 56370168 www.zolix.com.cn
ZAMP-A
103-1010 V / A
0.5mV
0.001 Ohm
1 Ohm
-5mA Iin +5mA
-5VVout+5V
2% (103-108)
5% (109-1010)
195*121*88 mm
Spectroscopy Instruments
Data Acquisition Systems
Zolix offers a range of integrated optical wavelength solutions, spectroscopy instruments include Spectrographs, Monochromators
and components including the light sources, detectors and data collection systems, such as A/D transformation data collector, lockin amplifier, photon counter etc. Zolix can provide high performance of multichannel data acquisition unit, photon counter and other
weak signal processor.
Lock-in Amplifier: DCS500PA high performance I/V amplifier
Data Acquisition Systems
Data Acquisition Unit: DCS300PA dual channel pre-amplifier data acquisition units.
Photon Counting: DCS202PC/DCS210PC single photon counting
DCS500PA
DCS300PA
DCS202PC/DCS210PC
+86 10 56370168 www.zolix.com.cn
21
Spectroscopy Instruments
Digital Lock-In Amplifier
DCS500PA High Performance I/V Amplifier
Data Acquisition Systems
Features
50mHz to 120kHz frequency range
ȋ
Low-noise current and voltage inputs
ȋ
1nV to 1V full-scale sensitivity
ȋ
Time constants extending from 10μs to 30s
ȋ
Up to 100dB dynamic reserve
ȋ
Up to 100dB CMMR
Specifications
Demodulator
Signal Channel
Voltage Input Mode
Full-scale Sensitivity
Current Input
Impedance
Voltage
Current
C.M.R.R
Dynamic Reserve
Gain Accuracy
Noise
Line Filters
Gounding
Single-ended or Differential
1nV to 1 V in a 1-2-5 sequence
106 or 108 V/A
10 Mȍ // 25pF, AC or DC coupled
1kȍ to virtual ground
100 dB to 10 KHz, decreasing by
6 dB/ oct
100 dB
0.2% typ, 1% max
10nV/¥Hz at 1 kHz
0.13pA/¥Hz at 1 kHz
0.013pA/¥Hz at 100 Hz
50/60 Hz and 100/120 Hz
BNC shield can be grounded or
floated via 1kȍ to ground
Reference Channel
Input
Frequency Range
50 mHz to 120 kHz
Reference Input
TTL or sine
Input Impedance
1 Mȍ//25 pF
Phase
Resolution
0.01° increments
Absolute Phase Resolution
1°
Relative Phase Resolution
0.01°
Phase Noise
Internal Ref.
External Ref.
Drift
Synthesized, 0.0001°rms at 1kHz
0.005°rms at 1 kHz (100 ms time constant, 12
dB/oct)
0.1°/Ď below 10 kHz
0.5°/Ď above 10 kHz
Harmonic Detection
2F, 3F, ćnF to 120kHz(n32,767)
Acquisition Time
22
ȋ
Internal Ref.
Instantaneous acquisition
External Ref.
(2 cycles+5 ms) or 40 ms, whichever is larger
+86 10 56370168 www.zolix.com.cn
Stability
Digital outputs
Display
Analog outputs
Harmonic rejection
Time constants
Synchronous filters
no zero drift on all setting
no zero drift on all setting
5 ppm/Ď for all dynamic reserve settings
-90dB
10μs to 3ks (200Hz)
10μs to 30s (200Hz)
(6, 12, 18, 24 dB/oct rolloff)
Available below 20 Hz
Internal Oscillator
Frequency
Range
Accuracy
Resolution
Distortion
Amplitude
Accuracy
Stability
Outputs
50 mHz to 120 kHz
25 ppm+30 μHz
1 mHz
-80 dBc (f10 kHz),
-70 dBc (f10 kHz)
0.10Vrms to 1 Vrms
1%
50 ppm/Ď
Sine, 50 ȍ output impedance
Display
Screen
Display quantities
Display types
3.5 inch, 320×240 TFT
4 channels of data to display X,Y,R and ș
Large numeric readout
Outputs
CH1 and CH2 Outputs
Function
X, Y, R, ș
±5 V
Amplitude
Impedance
100 ȍ
Interfaces
RS232 and RS232 to USB interfaces. All instrument
functions can be controlled and read through USB interfaces.
General
Power requirements
Voltage
220/240V AC
Frequency 50/60 Hz
Power
30 Ww
Dimensions
Width
259 mm
Depth
320 mm
Height
With feet
Without
Weight
115 mm
feet 102 mm
3.2 KG
Spectroscopy Instruments
Optical Chopper
DCS540 Optical Chopper System
Features
0.01Hz resolution
ȋ
1Hz~5KHz chopping frequency
ȋ
Standard TTL/COMS level input & output
ȋ
2.4inch LCD display
ȋ
Single Photoelectric encoder operating knob
Specifications
Frequency stability
Frequency drift
Frequency resolution
Operating
Operating temperature
250ppm/Ď(typ.)
<1%
0.01Hz
Single Photoelectric encoder
10-40Ď
Display
Display
Frequency display
Data Acquisition Systems
ȋ
2.4 inch, 320*240 LCD
6-digit
Input & Output
|Input&output
BNC
Input&output compatibility standard TTL/COMS level
Input voltage
0~5V
Input high level
> 3.6 V
Input low level
< 0.4 V
Min load resistance 500 ¢
Interface
RS232 to USB interfaces. All instrument functions can
be controlled and read through USB interfaces
General
ȋ
Power requirements
Voltage
Frequency
Power
ȋ
220 VACd10%
50 Hz d0.2 Hz
< 30 W
Dimensions
Width 206 mm
Depth 150 mm
Height 70 mm
Chopper Blade & Frequency
DCS540-01( 2 Slot) 1~99 Hz
DCS540-02 ( 10 Slot) 20~1 KHz, standard
DCS540-03 ( 15 Slot) 30~1.5 KHz
DCS540-04 ( 30 Slot) 60~3 KHz
DCS540-05 ( 60 Slot) 120~5 KHz
DCS540-06 (In 5 Out 7 Slot) In:10~500 Hz Out:14~700Hz
+86 10 56370168 www.zolix.com.cn
23
Spectroscopy Instruments
Data Acquisition Systems
DCS103 Data Acquisition System
The DCS103 can be used as a normal DAQ system for low signals. It's
Data Acquisition Systems
also used with Zolix Omni-Ȝ monochromators, detectors and so on.
Specifications:
ȋ
Measurement Signal Range:
Current input:±156μm嗣±40μA
Voltage input:±15.6mV嗣±4V
ȋ
A/D Converter Accuracy:15 Bits
ȋ
D/A Converter Accuracy:12 Bits(output DC0-10V,)
ȋ
Trigger input channel pulse width of input signal is not less than 0.5 μs
TTL level, pulse frequency is not greater than 2 MHz.
ȋ
Trigging Signal output:
High level: Width=25μS, Level=5V
Pulse: T=0.1mS嗣25ms, interval=0.1mS, Level=5V Square signal,
Frequency: 40Hz-10KHz
Features:
ȋ
ȋ
Wide measuring range can be changed to 256 times
of gain.
High measurement precision, high performance
operational amplifier and ±15 bits precision A/D
converter).
ȋ
Has a dual input channel of the same performance,
can be set respectively for the input DC voltage or
DC current input.
ȋ
With dual 0 to 10V DC output D/A transformation of
the channel.
ȋ
Sampling storage make sampling speed can be increased to 17947
times per second ( only 55.7184 μs for each sampling)
ȋ
Single channel and rate measurement can be
performed.
ȋ
Communicating Interface: USB2.0, RS232
ȋ
Outline 260mmX260mmX120mm
The software system is easy to operate.
ȋ
Weight 3.0kg
ȋ
DCS300PA Data Acquisition System
Specifications:
24
ȋ
Measurement Signal Range:
±1mA嗣±10mA
Current input
±1mV嗣±10V
Voltage input
ȋ
AUX Measurement Range: DC 0嗣10V
ȋ
Voltage Gain: 100-104
ȋ
Current Gain: 103-107
ȋ
Integration time: 10μs-10s
ȋ
Data Points: Ō2000( Stored in RAM)
DCS300PA data acquisition unit is a dual channel
ȋ
Temperature Measurement Range -30嗣100 Ď(AD590)
pre-amplifier of weak signal acquisition unit, an
ȋ
A/D Converter Accuracy: 16 Bits
upgrade version DCS103, covers DCS103 all data
ȋ
D/A Converter Accuracy:12 Bits(output DC0-10V,)
acquisition function, due to the increased the multi-
ȋ
Trigger output channel: can control shutter, solenoid
position, high-gain pre-amplifier, thus is suitable for a
ȋ
Trigger input channel: TTL rising edge
weak signal data acquisition.
ȋ
I/O 5 Input, 2 TTL Output
ȋ
CE
ȋ
Communicating Interface: USB2.0
ȋ
Power Supply: AC 100-240V ,50/60Hz(DC24V, 0.3A)
ȋ
Outline 260mmX260mmX120mm
ȋ
Weight 3.3kg
+86 10 56370168 www.zolix.com.cn
Spectroscopy Instruments
DCS Analog amplification data acquisition system
Analog Input Channels
2 Channels
12 bits
Range
DC 0V嗣10V
DC 0V嗣10V
Current Input
Voltage Input
DC Voltage Input Channels
Temperature Measurement
Channel
Input Range
No
No
Probe
Analog Output Channel
Remarks
DCS300PA Positive and
negative input need to
switch
DCS300PA: One channel
is used for high Voltage
Power control;One
channel is used for
Chooper Control
software trigger
software trigger
External trigger
External trigger
Pulse Signal Output every
No
data acquisition ends
Trigger Input Mode
Trigger Output
Data Acquisition Systems
D/A Converter Accuracy
DCS300PA
2 Channels
16 bits
Range:±1μm嗣±10mA
Gain:103嗣107
Range:±1mV嗣±10V
Gain:100嗣104
AUX Channel
DC 0V嗣10V
1 channel
AD590喑Measurement
Range:-30嗣100Ď
2 Channels
12 bits
A/D Converter Accuracy
DCS103
2 Channels
±15 bits
Range:±156nA嗣±40μA
Gain:20嗣28
Range:±15.6mV嗣±4V
Gain:20嗣28
Photon Counting Units
DCS200PC Photon Counting series
Photon Counter Channel
DCS202PC
One channel
DCS210PC
One channel
Analog Input Channels
No
Three channels
Analog Output Channel
No
One channel
software trigger
software trigger
No
External trigger
Chopping Mode
No
Yes
Life Measurements Function
No
Yes
Interface
Standard USB
interface
Standard USB interface
AC110V/220V
AC110V/220V
Trigger Mode
Instrument Size
Power Supply
Description
Photon counter rate:100 Mcps
Signal input range: 0~10V voltage input;
AD conversion accuracy: 16 bits;
Voltage output range: 0 ~ 10 VDA
conversion accuracy: 12 bits
receive instruction start count
External trigger input interface : TTL level
compatible
Chopper control function, enhance the signal to
noise ratio
Life measurement range:10μS~10S
Instrument Response Width: 1μS
240mm X 240mm X 120mm
DCS202PC series
DCS202PC Photon Counting, With the Company's production
of high-performance Omni-Ȝ spectrometers/monochromator,
efficient and stable light source, high sensitivity detectors, water
Raman signal to noise ratio up to more than 3000:1.
Specifications
ȋ
Photon counter channel
Photon counter rate:100 Mcps
ȋ
Interface
Standard USB interface
ȋ
Instrument size
240mmX240mmX120mm
ȋ
Certification
LVD, CE, RoSH
ȋ
Power Supply
AC110V/220V
ȋ
Weight
3.3kg
+86 10 56370168 www.zolix.com.cn
25
Spectroscopy Instruments
DCS210PC
DCS210PC single photon counter, in photon counting function it based on the
realization chopper control function phosphorescence and fluorescence lifetime
testing. The instrument is also equipped with 3DC voltage input analog signal
acquisition channel (16Bits, 0~10V) and 1 analog signal output channels (12Bits,
Data Acquisition Systems
0~10V), convenient combination system.
The instrument of the chopping mode can enhance the signal-to-noise ratio, With
the Company's production of Omni-Ȝ spectrometers/monochromator, efficient
and stable light source, high sensitivity detectors, greatly enhance the sensitivity
measurements, making the water Raman signal to noise ratio up to 4000:1.
DCS210PC photon counter lifetime measurement functions, with the Company's
production of Omni-Ȝ spectrometers/monochromators, pulsed light source
module, SAC-FS fluorescence of the sample chamber, high sensitivity detector,
can achieve>10uS long-life measurements, especially in strong light fluorescent
powder and rare earth sample measurement. Instrument Response width:1uS.
Achieve lifetime measuring range: 10uS~10S.
Specifications喟
One Photon Counter Channel Photon counter rate:100 Mcps
26
+86 10 56370168 www.zolix.com.cn
Three Analog Input Channels
Signal input range: 0~10V voltage input
AD conversion accuracy: 16 bits
One Analog Output Channel
Voltage output range: 0~10 VDA
conversion accuracy: 12 bits
Trigger Mode
External trigger input interface: TTL level compatible
software trigger: receive instruction start count
Chopping Mode
Chopper control function, enhance the signal to noise
ratio
Life Measurements Function
Life measurement range:10μS~10S
Instrument Response Width:1μS
Interface
Standard USB interface
Instrument Size
240mmX240mmX120mm
Power Supply
AC110V/220V
Weight
3.4kg
Spectroscopy Instruments
Software
Spectroscopy applications demand powerful software tools to provide everything from instrument control to acquisition of large
data volumes. Zolix has pay more attention to software over years and offers a range of software solutions according to customers'
requirement ;Focusing on our core markets of spectroscopy and related fields;
ZolixScan Controlling Software
Detector control software
ZolixScan is Zolix's detector control software with versions specifically designed to run detectors; Spectroscopy and detectors as
well as their associated accessories. All detectors parameters can be configured through the setup dialogues.
lock-in amplifier/chopper and motorized accessories can all be conveniently synchronized through a series of intuitive interfaces ;
Complex scanning sequences involving multiple gratings, filters and up to monochromators for fluorescence measurements-
Software
ZolixScan offers a dedicated platform for scanning monochromator applications. Monochromators, detectors, data acquisition unit,
including a tunable light source setupÿcan be captured prior to acquisition start and executed without further interverntion of the
user. ZolixScan can also handle multiple detectors control and data display for Absorption-Transmission-Reflection spectroscopy
etc.
Features
ȋ
With detection capabilities ranging from UV to IR region through range of single point detectorsÿSilicon, PMTs, PbS, InGaAs etc.
ZolixScan offers a dedicated platform for scanning applications
ȋ
Dedicated platform for scanning applications
ȋ
Step-by-step experiment building interface
ȋ
Complex scanning sequences involving multiple gratings
ȋ
Multiple detectors control and data display
ȋ
Post-acquisition mathematical data processing
SDK
Software Development Kit
A software development kit that allows you to control range of
detectors from your own application. Available as 32 and 64 bits
libraries for windows( XP, Win 7/8/10). Compatible with C/C++,
LabVIEW etc.
The SDK provides a suite of functions that allow you to configure
the data acquisition process in a number of different ways. There
are also functions to control the shutter operations etc. The SDK
will automatically handle its own internal memory requirements .
+86 10 56370168 www.zolix.com.cn
27
Spectroscopy Instruments
System Diagram
!
"#$
,
!
,
!
"#%$
,
Software
4#5
5- "
4#5
&!
$*
5
5
!$*+
,
#5
5- "
!
"#$
,
#5
&!
+*
!
!
&!
$
&
!-
!
$$
*
6$$
+$
$$
$)7
28
+86 10 56370168 www.zolix.com.cn
8,
39:'
2;
8,
*$$
Spectroscopy Instruments
@
)! !'*+$
&
"!<
&
[email protected]
&
'($
+
A
&
3 !
Software
$$,! +$$#
##
#123
2
,! #-
.$/$,0
#-
.$/$,0
2=$
:<!--
,$
3&5
39:'
&
,$
3&5
3!
&
,$
3&5
4:
:
39:'
='>
3#
:
-
&-!-
5!5?! !
@
#
!-&
3!B
CD
&
3!B
C
+86 10 56370168 www.zolix.com.cn
29
Spectroscopy Instruments
Sample Chambers
Different samples need different sample chambers to
Sample Chamber
help the users to get the best measurement result.
ȋ
SAC three-port sample chamber
ȋ
SAC-PL compact PL sample chamber
ȋ
SAC-Fluo fluorescence sample chamber
ȋ
SAC-RF total reflection sample chamber
SAC three-port sample chamber
ȋ
SAC is a three-port sample champer, which can be easily configured for transmittance,
reflectance, absorbance, fluorescence or Raman measurements.
ȋ
The SAC is compatible with the range of Zolix monochromators and spectrographs.
ȋ
All quartz lenses for excellent transmission in the spectral range 200 nm to 2.5 μm.
ȋ
Each quartz lens unit can be individually adjusted to provide either a collimated
or focused beam depending upon the sample and application requirements. The
collimated beam can be used for interference filter testing, transmittance, reflectance,
absorbance of colored glass. The focused beam can be used for transmittance,
reflectance, absorbance, density and concentration of gas/liquid.
ȋ
The sample holder comprises of an XY and rotation stage which allows critical
alignment and rotation of the sample to be performed in order to optimise the recorded
signal. XY translation of 10 mm in both axes and rotation of 360°is possible.
ȋ
Standard sample holder is SAC-SH01, which can hold sheet solid and liquid(need
cuvette).
Specifications喟
Wavelength Range
Amount of The Light Exit
Amount of Lens
Adjusting Range of the Height
Weight
SAC
200-2500 nm
3
3
213-243 mm
10 kg
Order information:
Model
SAC
SAC-Lens02
SAC-SH02
SAC-SH03
SAC-FM
30
+86 10 56370168 www.zolix.com.cn
Description
Sample chamber with standard quartz lens(SAC-Lens01) and standard
sample holder (SAC-SH01), 200-2500nm.
CaF2 IR lens with spectral range 0.2-8μm.
Solid powder sample holder
Cuvette holder, can support thicknessŌ12.4mm, width 12.4mm
Filter holder for Ÿ25mm filter
Spectroscopy Instruments
SAC-PL compact PL sample chamber
SAC-PL01 Fluorescence spectrum with the spectral range from 200 nm to 2500
nm. Laser as the excitation light source, the fluorescence emission at 2πangle, the
samples are in the face of the fluorescent light path collection, the fluorescence
collecting efficiency greatly. Sample chamber also can realize the xenon lamp +
monochromator output of monochromatic light, realize the excitation spectrum
measurement. Diameter 25 mm laser cut-off filter can be fixed in the sample
chamber, avoid excitation light into the spectrometer.
ȋ
SAC-PL02 Suitable for laser excitation, measure the photoluminescence spectrum.
Spectral range for 200-2500 nm. Sample chamber can support ARS circulation
liquid N2 refrigerator, minimum temperature 2 k, low temperature PL measurement.
ȋ
SAC-PL03 Fluorescence spectrum range 800-1400 nm. SAC-PL03 is reflection
light path design for fluorescence collection, which eliminated the chromatism,
so that the fluorescence signal from NIR to far IR spectral range can be a good
coupling to the spectrometer. Sample chamber adopts gilded mirror reflectivity
is as high as 98%, which improve the efficiency of fluorescence collection. Laser
as the excitation light source, the fluorescence emission at 2πangle, the samples
are in the face of the fluorescent light path collection, the fluorescence collecting
efficiency greatly.
Specifications
Wavelength Range
Amount Of The Light Exit
Amount Of Lens
Adjusting Range of the Height
Weight
SAC-PL
200-2500 nm
3
3
213-243 mm
10kg
Sample Chamber
ȋ
Sample chamber is equipped with a laser trap, if the sample is transparent, the
laser trap can avoid a stray light of laser to be reflected.
ȋ
SAC-PL04 is UV-Visible-NIR reflection optical structure sample chamber, with Al
coated reflector mirror, 200-2500nm, reflectivity≥90%.
Fig. 1
Fig. 2
Fig. 3
Order information:
Model
SAC-PL01
SAC-SH02
SAC-SH03
SAC-FM
SAC-FM
Description
Laser input optical Sample chamber, with standard
quartz lens and standard sample holder, 2002500nm.
Solid powder sample chamber
Cuvette holder, can support thicknessŌ12.4mm,
width 12.4mm
Filter holder for Ÿ25mm filter
Filter holder for Ÿ25mm filter
Model
SAC-PL02
SAC-SH02
SAC-SH03
SAC-FM
SAC-FM
Model
Model
SAC-PL03
SAC-SH02
Description
IR reflection optical structure sample chamber, with
gold coated reflector mirror, reflectivity≥98%.
Solid powder sample chamber
SAC-PL04
SAC-SH02
Description
Cryocooler sample chamber, with standard quartz
lens and standard sample holder, 200-2500nm.
Solid powder sample chamber
Cuvette holder, can support thicknessŌ12.4mm,
width 12.4mm
Filter holder for Ÿ25mm filter
Filter holder for Ÿ25mm filter
Description
UV-Visible-NIR reflection optical structure sample
chamber, with Al coated reflector mirror, 2002500nm, reflectivity≥90%.
Solid powder sample chamber
+86 10 56370168 www.zolix.com.cn
31
Spectroscopy Instruments
SAC-Fluo fluorescence sample chamber
Features:
ȋ
Big space design, easy to operate
ȋ
F/1 optical design, the best signal
collection efficiency
ȋ
System automatically protect
the detector when open sample
compartment during testing
Sample Chamber
ȋ
Please order motorized filter wheel
separately ( refer to Page34 SD25-R
series.)
ȋ
Fluorescence quantum yield
integrating sphere(SAC-IS option)
ȋ
Polarization accessory( option)
Please refer to Page 55 if you want to know
more details for application ; Welcome to
contact us and discuss your requirements !
SAC-RF total reflection sample chamber
Features:
32
ȋ
Design for transmittance, reflectance, absorbance
measurement, using reflection optical structure,
elimination of the influence of the chromatic aberration.
ȋ
For liquid and other transparent materials
ȋ
SAC-RF01 is UV-Visible-NIR reflection optical structure
sample chamber, with Al coated reflector mirror.
ȋ
SAC-RF02 is IR reflection optical structure sample
chamber, with gold coated reflector mirror.
+86 10 56370168 www.zolix.com.cn
Spectroscopy Instruments
Accessories for SAC series product
SAC-SH02
standard sample holder, which can hold sheet
solid and liquid (need cuvette)
Solid powder sample holder
SAC-SH03
SAC-FM
Cuvette holder, can support thicknessŌ12.4mm,
width 12.4mm
Filter holder for 25mm filter
Sample Chamber
SAC-SH01
SAC-IS
Fluorescence quantum yield integrating sphere
+86 10 56370168 www.zolix.com.cn
33
Spectroscopy Instruments
Motorized Filter Wheels
The SD25 six position filter wheel holds up to six 25mm diameter filters(aperture 22mm). For the automatic filter wheel, stepping
motor drives the compact filter wheel via the monochromator/spectrograph controller. The SD25 filter wheel is fully compatible with
the Omni-Ȝ series monochromators/spectrographs.
Mutomatic Filter Wheels
Features
ȋ
Six Position Stepping Motor Controlled Filter Wheel
ȋ
Accommodates 25mm diameter filters (option)
ȋ
Integrates with Omni-Ȝ Monochromator/Spectrograph and
Software
SD25 series
SD25-R series
Filter Spectral Transmittance Curves
SD-G6-25
SD-G1(~5)-25
SD-G7-25
SD-G9-25
SD-G8-25
SD-G10-25
Selections
ȟModel
Spectral Range
Filter#
Model
(nm)
NO.1
NO.2
NO.3
NO.4
NO.5
NO.6
SD25
SD25-R
It doesn't have filter; Please fix filters with 25mm diameter freely
SD25-IR1
SD25-IR1-R
200-1500
none
SD-G1-25
SD-G2-25
SD-G3-25
SD-G4-25
SD-G5-25
SD25-IR2
SD25-IR2-R
200-2000
none
SD-G1-25
SD-G2-25
SD-G3-25
SD-G4-25
SD-G6-25
SD25-IR3
SD25-IR3-R
400-3000
none
SD-G2-25
SD-G3-25
SD-G4-25
SD-G6-25
SD-G7-25
SD25-IR5
SD25-IR5-R
650-5000
none
SD-G3-25
SD-G4-25
SD-G6-25
SD-G7-25
SD-G8-25
SD25-IR8
SD25-IR8-R
800-8000
none
SD-G4-25
SD-G6-25
SD-G7-25
SD-G8-25
SD-G9-25
SD25-IR12
SD25-IR12-R
1300-12000
none
SD-G6-25
SD-G7-25
SD-G8-25
SD-G9-25
SD-G10-25
SD25-R series is for Omni-Ȝ200i and sample chamber SAC-FLUO only ;SD25 series is for Omni-Ȝ300i/500i/750i
34
+86 10 56370168 www.zolix.com.cn
Spectroscopy Instruments
Fiber Adapters
BFC series fiber adapter can be compatible with the range of Zolix monochromators and spectrographs or sample chamber.
BFC-441
Adjustable fiber adapter with horizontal translation
capability for 13mm diameter fiber optic bundle for Zolix
monochromators and spectrographs.
Adjustable fiber adapter with horizontal translation
Fiber Adapters
BFC-442
capability for SMA905 Termination fiber for Zolix
monochromators and spectrographs
BFC-443
Adjustable fiber adapter with horizontal translation
capability for 10mm diameter fiber optic bundle for Zolix
monochromators and spectrographs.
BFC-447
Adjustable(XY) fiber adapter, for 10mm, 13mm diameter
fiber optic bundle, SMA905 Termination fiber.
BFC-641
SMA termination fiber to SAC Sample Chamber.
+86 10 56370168 www.zolix.com.cn
35
Light Sources
37
Light Sources
38
Xenon Light Soures and Tungsten-halogen Light Sources
39
150W Xenon Light Sourceÿ GLORIA-X150A
41
500W Xenon Light Sourceÿ GLORIA-X500A
42
150W-250W Tungsten-halogen Light Source ÿ GLORIA-T150A/T250A
43
47
Tunable Monochromatic Light Source
Light Source Accessories
44
Lens Sets
45
Others
50
50
Light Sources for Spectroscopy
LED light sources
Light Sources
Light Sources
We offer wide range of light source from UV to IR including arc light source, halogen Light Source, tunable monochromatic
light source and LED light source. And all the necessary components & accessories to make them work well.
Whether you need single-wavelength or broadband radiation - Zolix has the right light source. We offer small, bright "LED
sources" and continuous light source.
All light sources are designed for versatility, flexibility and efficiency, providing good solutions for individual applications.
Welcome to contact us for discussing your application which light source and accessories are best suited!
Spectral radiance curve
Spectral irradiance of 30W Deuterium Lamp,75W/150W,450W Xenon Lamp,100W/150W Tungsten-Halogen Lamp
Light Source
Spectral irradiance of 150W Xenon Lamp, 150W, 250W Tungsten-Halogen Lamp
10
2
250W Halogen
10
150W Halogen
1
150W Xe
10
10
0
-1
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
Wavelength [ nm ]
+86 10 56370168 www.zolix.com.cn
37
Light Sources
Xenon Light Soures And Tungsten-halogen Light Sources
Light Source
Model Selections
Model
GLORIA-X150A
GLORIA-X500A
GLORIA-T150A
GLORIA-T250A
Light source
housing
Spectral range
Power
Center Height
Color Temperature
Light Ripple
Weight
200-2500nm
150W
137-173mm
6000K
Ō0.5%
4.5kg
250-2500nm
500W
157-193mm
6000K
Ō1%
5.8kg
300-2500nm
150W
137-173mm
3000K
Ō0.5%
4.5kg
300-2500nm
250W
137-173mm
3000K
Ō0.5%
4.5kg
Power Supply
Power
Output Current
Current Ripple
Output Voltage
Input Voltage
Weight
150W
7-9A
Ō0.05%/h(@8.5A)
0-25V
AC110/220V±10%
4kg
500W
0-30A
Ō0.05%/h(@25A)
0-30V
AC110/AC220V±10%
4kg
150W
0-6.5A
Ō0.05%/h(@6.25A)
0-25V
AC110/220V±10%
4kg
360W
0-10.8A
Ō0.05%/h(@10.5A)
0-25V
AC110/220V±10%
4kg
Lamp Sheet
Power
(W)
Model
Type
Voltage
(V)
Current Lifetime
(A)
(h)
Approx.
flux (lm)
Intensity Approx.Luminance
2
(cd)
(cd/mm )
Luminous
Area(mm)
Xe
150
LSB-X150AOFR
Ozone-free
17.5
8.5
3000
2900
290
200
0.5×1.6
Xe
150
LSB-X150AUV
UV Enhanced 20
7.5
3000
3000
300
150
0.5×1.7
Xe
150
LSB-X150
Economical
18
8.5
1000
3200
320
ÿ
0.8×2.0
Xe
500
LSB-GX500AOFR Ozone-free
17
28
2000
14500
1450
400
0.9×2.5
Xe
500
LSB-GX500
20
25
1000
14200
1420
ÿ
1×2.7
Economical
Hg(Xe)
500
LSB-GMX500
Economical
25
20
ÿ
ÿ
ÿ
ÿ
3
Halogen
150
LSB-T150
Economical
24
6.25
2000
3200
ÿ
ÿ
8×4
Halogen
250
LSB-T250
Economical
24
10.5
300
9000
ÿ
ÿ
8×4
Lens Holder
Filter Holder
Iris Diaphragm
Light Path Sealing
Components
Fiber Bundles
38
+86 10 56370168 www.zolix.com.cn
Fiber Coupling
Components
Beam Steering
Components
Fiber Bundles
Liquid Fiber
Beam-Splitting
Components
Filter Holder
Light Sources
150W Xenon Light Source ÿ GLORIA-X150A
Xe arc lamp light sources are the preferred artificial sources to simulate sunlight.
The high color temperature (6000K) of the Xenon lamps is a close match to the
solar temperature. This results in very similar solar spectra in the UV and VIS
although the source has some Xe emissions lines in the near IR.
Application for fluorescence, luminescence and phosphorescence, absorbance and
reflectance, photochemistry, photolithography, solar simulation and so on.
ȋ
Spectral range from UV to VIS(200-2500nm)
ȋ
Optical axis height is 157-193mm
ȋ
Output beam diameter is 46mm
ȋ
Supports wide range of accessories
ȋ
Fan cooled housing
More light
A spherical reflector collects the output from the rear of the lamp and focuses it
41.6 mm
on or near the arc, for collection by the condenser. The output is increased by as
298 mm
much as 60%.
Lamp adjustment
35 mm
137 mm
The housing has precise external lamp adjusters.
212 mm
155 mm
and slit illumination. In many applications, this eliminates the need for readjusting
any optics located beam path outside the housing.
Light Source
They let you place the arc where you want it. This is important for simplifying fiber
27 mm
Anode
Arc Lamp Power Supply
Reflector
Current and light ripple
Direct current generated by rectification always has a current ripple (superimposed
Collimating light
on the direct current). Current ripple is the main factor of cathode fissuring and
Reflector
therefore greatly influences lamp luminous flux or radiant power and lamp life.
But for the most (scientific) applications the light ripple is most important. This not
only depends on the current ripple, but on the operation conditions typical light
ripple of our arc light sources is 0.5%.
Igniters
To ignite an arc lamp it is necessary to ionize the insulation gas between the
electrodes. This is done by a high voltage discharge or flash. To get the flash into a
Output beam
stable stationary arc discharge, certain conditions must be met:
A sufficient high ignition voltage from the ignitor and a sufficient high electrical
energy in the ignition spark.
A sufficient quick start of current flow and adequate open circuit voltage.
The two last conditions must be achieved by the power supply. Some arc lamps
require constant current, others constant power for optimal operation. The power
supplies must be designed meet the operation conditions.
+86 10 56370168 www.zolix.com.cn
39
Light Sources
Current or power adjust
Constant light output
During operation the tungsten from the electrodes evaporates slowly
The output intensity of a new lamp decreases
and deposits on the inside of the lamp envelope. This reduces the
continously during lamp life. To irradiate your
radiated output by up to 30% during lamp life. If application requires
targets with constant intensity (during lamp
constant light output, the lamp current must be adjustable within a
life) you must start a new lamp with 80%
certain range
of lamp current or power value and then
Specification of power supply
gradually apply higher current. When the
rated current value is reached the lamp is
110/220V AC ±10%
250W
150W
7-9A
Ō0.05%(@8.5A)
20KV
0.05%(8.50A )
Voltage
Power consumption
Power
Adjustable current
Current ripple
Line voltage
Light output ripple
statistically used up.
Ordering Information
Light Source
To build a complete light source you will need: Lamp housing,
condensing optics, lamp with appropriate adapter, electrical
interface, cable and power supply. As an option we suggest the rear
reflector for more output.
Model
Description
Detail
GLORIA-X150A
150W Xenon Light Source
150W Xenon Light Source(GLORIAX150A)includes housing, power supply
and lamp(LSB-X150)
Lamp Sheet
Model
Power(W)
Voltage(V)
Current(A)
Lifetime
(h)
Approx.
flux (lm)
Intensity
(cd)
Approx.Luminance
2
(cd/mm )
Luminous
Area(mm)
Lamp size
(L*D)mm
LSB-X150AOFR
150
17.5
8.5
3000
2900
290
200
0.5×1.6
127*20
LSB-X150AUV
150
20
7.5
3000
3000
300
150
0.5×1.7
127*20
LSB-X150
150
18
8.5
1000
3200
320
ÿ
0.8×2.0
127*20
Note: LSB-X150AUV is UV enhanced with spectral range 200-2500 nm, please vent the ozone to the outside.
40
+86 10 56370168 www.zolix.com.cn
Light Sources
500W Xenon Light Source ÿ GLORIA-X500A
500W Arc light housing expand to operates 350 W Xe and 500 W Hg(Xe)arc lamps
under optimal and for these lamps necessary conditions. Switching between the
lamps only requires changing the lamp adapter to position the lamp in the center of
the housing.
Spectral range from UV to VIS(200-2500nm)
ȋ
Output beam diameter is 46mm
ȋ
Optical axis height is 157-193mm
ȋ
ȋ
A spherical reflector collects the output from
the rear of the lamp and focuses it on or near
the arc, for collection by the condenser.
Typical light ripple of our arc light
sources is less than 1%.
ȋ
Supports wide range of accessories
ȋ
Fan cooled housing
ȋ
ȋ
The output is increased by as much as 60 %
Xe arc Iamp light sources are the preferred artificial sources to simulate sunlight. The
high color temperature (6000K) of the Xenon lamps is a close match to the solar
temperature. This results in very similar solar spectra in the UV and VIS although the
source has some Xe emissions lines in the near IR.
Application for fluorescence, Luminescence and Phosphorescence, Absorbance and
Reflectance, Photochemistry, Photolithography, Solar simulation
Cooling
41.6 mm
353 mm
Proper cooling is essential for correct lamp operation. The bulb temperature of arc
able to withstand the high gas pressure due to a temperature-related change of the
quartz structure (recrystallization). Because of potential current conductor oxidation,
35 mm
157 mm
the socket temperature must not exceed 230Ď.
27 mm
Light Source
lamps should not exceed 600-900Ď,Because at higher temperatures the bulb is not
Safety
212 mm
155 mm
Our lamp housings include safety features to prevent lamp damage and accidental
exposure. The door inter-lock prohibits the operation of the lamp while the door is
‫఺ك‬ሺࢺ
Anode
open. Overheating of the lamp caused by a defect is avoided by a thermal interlock
which shuts down the power supply.
Lens
༅ঀ
Ordering Information
To build a complete light source you will need: Lamp housing, condensing optics,
lamp with appropriate adapter, electrical interface, cable and power supply. As an
ኵቌߗ
Reflector
ഋஇۭඹঀ
option we suggest the rear reflector for more output.
Collimating light
‫ࢺݑ఺ك‬
Cathode
Model
Description
GLORIA-X500A
500W Xenon
Light Source
Detail
500W Xenon Light
Source(GLORIA-X500A)
includes housing, power
supply and lamp(LSB-X500)
Output beam
Lamp Sheet
Model
Power(W)
Voltage(V) Current(A) Lifetime (h)
Approx.
flux (lm)
Intensity Approx.Luminance Luminous
2
(cd)
(cd/mm )
Area(mm)
LSB-GX500AOFR
500
17
28
2000
14500
1450
400
0.9×2.5
175*30
LSB-GX500
500
20
25
1000
14200
1420
ÿ
1×2.7
190*35
Lamp size
(L*D)mm
Tips: Xe and Hg (Xe) lamps are strong UV sources and emit dangerous levels of ultraviolet radiation. Exposure to UV, even for short periods,
can cause severe skin and eye burns. Always wear protective eyewear and gloves or clothing, when working near these sources.
+86 10 56370168 www.zolix.com.cn
41
Light Sources
150W-250W Tungsten-halogen Light Source ÿ GLORIA-T150A/T250A
ȋ
Stable VIS-NIR sources
ȋ
Precision external lamp adjustments
ȋ
Choice of different UV-NIR condensing optics for collimated beam
ȋ
Supports wide range of accessories
The collimated bean diameter is 46mm and optical axis height is from 157 to 193mm.
Cooling
Tungsten halogen lamps become up to 900 Ď hot (surface temperature) during
operation. They require a safe, temperature-controlled environment. Below 200Ď the
halogen cycle does not work. There is also a maximum permitted pinch temperature
which must not in any case be exceeded during operation.
The housing has a cooling fan built in that provides the proper air flow.
Lamp adjustment
The housing has precise external lamp adjusters. They let you place the filament
41.6 mm
298 mm
where it is needed. This is important for simplifying fiber and slit illumination. In many
applications this eliminates the need for readjusting any optics located in the beam
path outside the housing.
35 mm
137 mm
Light Source
Reflector
27 mm
A spherical reflector collects the output from the rear of the lamp and focuses it on or near
212 mm
155 mm
the arc, for collection by the condenser. The output is increased by as much as 60%.
Power Supply
Power(W)
Current(A)
Voltage(V)
Current ripple
Input voltage(V)
LSP-T150A
150
0-6.5
0-25
0.05%
110/220V AC±10%
LSP-T250A
300
0~10.8
0~25
0.05%
110/220V AC±10%
Lamps
Safety Tips
ȋ
ȋ
42
Although compared to arc and
deuterium lamps it is only a little,
tungsten halogen still produce UV
radiation. Especially in the high
wattages the ultraviolet radiation is
hazardous. Always wear protective
eyewear. When imaging the filament
to small probes you will even need
welding goggles during adjustments
because of glare.
Tungsten halogen lamps reach
surface temperatures up to 900°
C during operation. So the cooling
period can last up to 15 minutes!
Only then is it safe to touch the lamp.
+86 10 56370168 www.zolix.com.cn
Model
Power(W)
Current(A)
Voltage(V)
LSB-T150
LSB-T250
150
250
6.25
10.5
24
24
Approx.
flx (lm)
3200
9000
Color
temperature(K)
3200
-
Average
life (h)
2000
300
Ordering Information
To build a complete halogen source you will need: Lamp housing, condensing optic,
lamp and adapter, power supply and interface. As an option you might choose the
rear reflector for more output.
Model
Name
Details
GLORIAT150A
150w Tungstenhalogen Light Source
150W Tungsten-halogen Light Source(GLORIA-T150A)
housing(LSH-T150A),
power supply(LSP-T150A), lamp(LSB-T150).
GLORIAT250A
150w Tungstenhalogen Light Source
250W Tungsten-halogen Light Source(GLORIA-T250A)
housing(LSH-T250A),
power supply(LSP-T250A), lamp(LSB-T250).
Light Sources
Tunable Monochromatic Light Source
The Tunable Light Source (TLS) are pre-aligned, pre-assembled
illumination systems capable of outputing monochromatic light from
200nm. This is a complete plug and play system and includes TLS-C1
software.
TLS is composed of Zolix light source and spectrometer. It is very
convenient for the users who want the flexibility of a modular design
and the simplicity of an integrated system.
Wavelength
Wavelength
RepeatAccuracy
ability
Weight
250-2200 [email protected]
nm
[email protected]
[email protected]
[email protected]
±0.25nm
±0.1nm
26kg
350-2200 [email protected]
nm
[email protected]
[email protected]
[email protected]
±0.25nm
±0.1nm
26kg
250-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
45kg
300W Xenon 喡1%
300-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
45kg
TLS3-X300PU
300W UV
Xenon
喡1%
200-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
45kg
TLS3-X500A
500W Xenon 喡1%
250-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
48kg
TLS3-T150A
150W
TungstenHalogen
喡0.5%
350-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
45kg
TLS3-T250A
250W
TungstenHalogen
喡0.5%
350-2200 [email protected] [email protected]
±0.2nm
nm
[email protected] [email protected]
±0.1nm
45kg
Lamp type
TLS15-X150A
150W Xenon 喡0.5%
TLS15-T150
150W
TungstenHalogen
TLS3-X150A
150W Xenon 喡0.5%
TLS3-X300P
喡0.5%
Spectral
range
Resolution
+86 10 56370168 www.zolix.com.cn
‫⎽ٶ‬
Bandwidth
Light
ripple
Model
Tunable Monochromatic
Light SourceV
TLS Selections
43
Light Sources
TLS15-X150A/TLS15-T150A
TLS3-X150A/TLS3-T150A/TLS3-T250A
TLS3-X300P/TLS3-X300PU
TLS3-X500A
‫⎽ٶ‬
Tunable Monochromatic
Light SourceV
Drawings(mm)
44
+86 10 56370168 www.zolix.com.cn
Light Sources
Accessories
Tunable Light Source
KƵƚƉƵƚWŽǁĞƌĨƌŽŵ/ŶƚĞŐƌĂƚŝŽŶ^ƉŚĞƌƌĞ
ϭϲ
WŽǁĞƌĞŶƐŝƚLJ;ƵtͬĐŵϸͿ
; ͬ ϸͿ
ϭϰ
ϭϮ
ϭϬ
Ɣ Uniform Light Uniformity˚98%
ϴ
ϲ
ϰ
Ϯ
ϮϬϬ
Ϯϱϱ
ϯϭϬ
ϯϲϱ
ϰϮϬ
ϰϳϱ
ϱϯϬ
ϱϴϱ
ϲϰϬ
ϲϵϱ
ϳϱϬ
ϴϬϱ
ϴϲϬ
ϵϭϱ
ϵϳϬ
ϭϬϮϱ
ϭϬϴϬ
Ϭ
tĂǀĞůĞŶŐƚŚ;ŶŵͿ
Ɣ Collimated Light Divergence
Angle ( half angle) ˘0.3e
Ɣ Convergent Light
Beam Size˘1mm
KƵƚƉƵƚWŽǁ
WŽǁĞƌĨƌŽŵ&ŝďĞƌƵŶĚ
ĚůĞ
;ϭϵĨŝďĞƌƐͿ
ϭϬϬ
Ɣ Fiber Coupling
ϵϬ
ϴϬ
WŽǁĞƌ;ƵtͿ
ϳϬ
KƵƚƉƵƚWŽǁĞƌĨƌŽŵ^ůŝƚ;ǁŝĚƚŚϯŵĂŶĚŚĞŝŐŚ
ŝŐŚƚϭϰŵŵͿ
ϲϬ
ϱϬ
ϭϮϬϬϬ
ϰϬ
ϯϬ
ϮϬ
ϭϬϬϬϬ
ϭϬ
ϮϬϬ
ϮϲϬ
ϯϮϬ
ϯϴϬ
ϰϰϬ
ϱϬϬ
ϱϲϬ
ϲϮϬ
ϲϴϬ
ϳϰϬ
ϴϬϬ
ϴϲϬ
ϵϮϬ
ϵϴϬ
ϭϬϰϬ
ϭϭϬϬ
Ϭ
ϴϬϬϬ
WŽǁĞƌ;ƵtͿ
tĂǀĞůĞŶŐƚŚ˄Ŷŵ˅
ϲϬϬϬ
ϰϬϬϬ
ϰϬ
ϮϬϬϬ
tĂǀĞůĞŶŐƚŚ;ŶŵͿ
Integration Sphere Uniform Light
Diameter
(mm)
50
100
150
200
Model
IS-050-14
IS-100-25
IS-150-38
IS-200-50
Optical axis
height(mm)
130-165
145-165
155-165
160-165
uniformity
98%
98%
98%
98%
Model
Mirror
Coating
Spectral range
Divergence
half-angle
Optical
Beam size
TLS-A5
Al
Full wave band
喡0.3°
3-25mm
TLS-A6
Au
IR
喡0.3°
3-25mm
TLS-A7
Al
Full wave band
喡0.3°
3-25mm
TLS-A8
Au
IR
喡0.3°
3-25mm
‫⎽ٶ‬
Collimated light adapter
Tunable Monochromatic
Light SourceV
Ϭ
No mount for filter wheel
Must be used with filter
wheel together
Applications
ȋ
PEC Photochemistry Measurement System
ȋ
ȋ
Transmission/Absorption /Reflection Measurement System
ȋ
Detector Spectral Responsivity Measurement System
Optical Lens Spectral Transmittance Measurement System
Eye Protection Products Measurement System
ȋ
Solar Cell Quantum Efficiency Measurement System
ȋ
ȋ
The fluorescence Spectrum Measurement (as excitation light)
ȋ
Surface Photovoltage Test
+86 10 56370168 www.zolix.com.cn
45
Light Sources
Adaptor for EQ Light Source(Model: TLS-Q1)
Zolix monochromator not only support Xenon/Tungsten-halogen Light Source, but also connect with Energetiq broadband light
source ; This adaptor can upgrade to tunable light source if you have EQ light source directly ;
EQ99+300i TLS output power
Test condition
1200g/mm, blaze wavelength: 300nm
Scan step: 5nm
Power˄uW˅
Spectral range: 200nm to 1200nm
Tunable Monochromatic
Light SourceV
Wavelength˄nm˅
‫⎽ٶ‬
Zolix 200mm monochromator with EQ-99X drawings
Zolix 320mm monochromator with EQ-99X drawings
46
+86 10 56370168 www.zolix.com.cn
Light Sources
Light Source Accessories
You probably have to image the
Light Source Accessories
arc and filter, attenuate or split the
Lens Holder
Filter Holder
Iris Diagramph
Beam Steering Component
beam, change the beam form or
direction, place a shutter in the
beam, control the light intensity
or carry the light to a sample via
a single filter or a filter bundle. We
offer some useful and necessary
accessories to customize your
Beam-Splitting Component
Light Path Sealing Component
Fiber Coupling Component
light source; these couple directly
to the output of the lamp housing
condenser.
Note: the condenser size of GLORIA
series is 59mm.
Lens Holders
>@
>@
Model
THRU
0䌃こ
>
@
Aperture
size(mm)
LLM50.8 46
Outer
Lens outer
diameter(mm) diameter(mm)
Condenser
size (mm)
70
59
50.8
‫⎽ٶ‬䭱У
>@
Lens Set
Lens outer diameter
(mm)
Material
Glass
50.8
(min size:46mm)
Quartz
Focal
length(mm)
75
100
150
200
250
300
75
100
150
200
250
300
400
F#
Model
1.6
2.2
3.3
4.3
5.4
6.5
1.6
2.2
3.3
4.3
5.4
6.5
8.7
LCG50.8-75
LCG50.8-100
LCG50.8-150
LCG50.8-200
LCG50.8-250
LCG50.8-300
LCQ50.8-75
LCQ50.8-100
LCQ50.8-150
LCQ50.8-200
LCQ50.8-250
LCQ50.8-300
LCQ50.8-400
Light Source Accessories
Lens Sets
+86 10 56370168 www.zolix.com.cn
47
Light Sources
Others
Filter Holders
LFM2-50
LFM3-50
>@
THRU
0䌃こ
>@
@
>@
>
@
>@
>@
Light Source Accessories
@
>
These holders are open to allow easy access
square filters simultaneously.
>
0 @
>
to the filters. You can insert various round or
@
>
>@
>
LFM1-50
@
Model
Condensor
size(mm)
Aperture
size(mm)
Filter size(mm)
Diam or square
Thickness max
LFM1-50
LFM2-50
LFM3-50
59
59
-
46
46
-
50
50
50
20
10
10
Mode
Open
Iris Diaphragm
These variable apertures are excellent for light attenuation and as
>@
>@
>@
lens aperture stops. A lever located on the top of the diaphragm
‫⎽ٶ‬䭱У
controls the aperture. Do not use these in the unfiltered output of
THRU
0䌃こ
@
>
sources rated at more than 200 W. Use either a water filter, dichroic
mirror or neutral density filter iris
Model
Cond.size(mm)
Cond.size(mm)
Length(mm)
LMI50
59
2~50
32
Adjustable Spacer Tube
>@
>@
This flanged tube is useful in several ways. You can use it to enclose
the beam path between separate components like monochromators
0 >@
48
+86 10 56370168 www.zolix.com.cn
@
̚ ̚
>
and lamp housings. It also holds secondary focusing lenses beyond
the condensers on your light sources.
Model
Cond.size
(mm)
Aperture
diameter
(mm)
Outer
diameter
(mm)
Range of
extension A
(mm)
LHP150
59
46
80
110~160
Light Sources
/%7
>@
90°Beam Turner
光束转向组件度
The design of many optical systems is simplified if the beam from
the lamp housing can be turned to go up or down, or sometimes
>@
just turned 90 degrees in the horizontal plane. In other applications
only a small portion of the spectrum is required, and the rest must
0 @
>
>
@
>@
Condenser Aperture Spectral
Diameter Thickness
size(mm)
size(mm) range(nm)
(mm)
(mm)
LBT46 59
46
UV-Vis
should be removed before using optical fibers or irradiating some
samples. These beam turners consist of a mirror and a holder
placing the mirror under 45c in the collimated output beam of
Mirror size
Model
be removed. For example the infrared from arc and halogen lamps
80
5
our light sources. You can reflect the entire lamp output or only a
selected portion of the UV in the VIS spectrum. The beam turners
couple directly to the lamp housing condensers or flanged optical
accessories.
Beam-Splitting Components
>@
>
@
>
@
>
@
>@
If user has limited wavelength requirement, please use this part
by adding dichroic filter. It is very convenient for user to exchange
optics. Dichroic filters are designed for high reflectance and
polarization insensitivity over a limited spectral range. They pass one
portion of the spectrum and block another. Use them to shape the
output of a broadband source.
Model Condenser size(mm) Dichroic filter size(mm) Thickness (mm)
LSM46 59
85x60
2
Light Source Accessories
>@
0 Fiber Couplers
>@
These assemblies focus the collimated light of our light sources into
a filter or filter bundle. The one end has a male flange to couple to
the light source; the other end accepts fiber bundles.
0 @
>
Model
Collimated
Condenser
mirror
Lens
size(mm)
size(mm)
FCM-GF2.2 59
50.8
F/2.2 glass
FCM-QF2.2 59
50.8
F/2.2 quartz
‫⎽ٶ‬䭱У
>@
Fiber bundles
Glass filter
bundles with
bundle diam.
8mm and 16mm
+86 10 56370168 www.zolix.com.cn
49
Light Sources
Light Sources for Spectroscopy
LED light sources
Application
Photocatalysis, ultraviolet analyzer biological genetic engineering,
molecular genetics, medical and health, biological products,
pharmaceutical research, health and epidemic prevention, dye
chemical industry, petroleum chemical industry, textile industry,
etc.
Light Sources for Spectroscopy
Feature:
50
ȋ
Efficient electro-optic conversion efficiency, energy
conservation and environmental protection
ȋ
Small volume, convenient to carry, convenient for system
integration
ȋ
Digital switch control, remote communication control, 1-100%
light intensity adjustment
ȋ
Set work plan for exposure time and light intensity.
LED order information
Model
Wavelength
Output
Power
Iop (mA)
Model
Wavelength
Output
Power
Iop(mA)
M265L
265nm
50μW
20
M620L
620nm
240mW
700
M280L
280nm
50μW
20
M635L
635nm
320mW
700
M310L
310nm
50μW
20
M660L
660nm
280mW
350
M365L
365nm
420mW
700
M690L
690nm
240mW
350
M395L
395nm
450mW
700
M710L
710nm
200mW
350
M405L
405nm
400 mW
700
M735L
735nm
80mW
350
M425L
425nm
280mW
700
M760L
760nm
50mW
350
M450L
450nm
320mW
700
M808L
808nm
80mW
350
M470L
470nm
240mW
700
M850L
850nm
80mW
350
M515L
515nm
180mW
700
M880L
880nm
150mW
350
M525L
525nm
180mW
700
M900L
900nm
110mW
350
M550L
550nm
200mW
700
M940L
940nm
50mW
350
M560L
560nm
150mW
700
M980L
980nm
50mW
350
M590L
590nm
80mW
700
M1020L 1020nm
50mW
350
+86 10 56370168 www.zolix.com.cn
Light Sources
LED power supply order information
Model
CH1(output current
mA)
CH2(output current
mA)
CH3(output current
mA)
CH4(output current
mA)
MLED4-1
MLED4-2
MLED4-3 MLED4-4
MLED4-5
700
20
20
20
20
700
700
700
700
20
700
700
700
350
350
700
700
350
350
350
Radiation mode
Fixed irradiation: irradiation power (0-100%) adjusted (adjusting the
duty ratio), modulation switch frequency 120 Hz, the irradiation time
can be set maximum 9999.9 s, long time exposure can be realized
by manual control.
Control mode
Manual control, Digital signal control(turn on, turn off), RS232 control
(turn on, turn off)
Cooling
Fan
Input AC 110V~220V, output DC12~4A
Environmental
temperature
Working temperature: +5~+35Ď,storage temperature: -10~+55Ď
Environmental
humidity
Working/Storage: RH 20~80%
Weight
Light Sources for Spectroscopy
Power supply
1.5kg
LED holder order information
Model
MLED-POST1
MLED-POST2
MLED-POST3
MLED-POST4
LED number
1
2
3
4
LED holder can fix the LED conveniently, and the height( up to 200 mm), direction are
adjustable. The MLED-POST1, MLED-POST2, MLED-POST3, MLED-POST4, It can fix
one to four LED at the same time respectively.
+86 10 56370168 www.zolix.com.cn
51
Application Solutions
Application
Zolix has many years of experience designing spectroscopy instruments. We are not only supply optical components, but
also design optical systems; We offers high-performance spectrometers, spectrographs and detectors to many demanding
spectroscopy applications including Fluorescence/Photoluminescence, Raman Spectroscopy, Absorbance, Transmittance and
Reflectance, Plasma Emission Spectroscopy and Solar Cell Spectral Response/QE/IPCE etc.
Solar Cell Testing & Characterization
Fluorescence/Photoluminescence
Raman Spectroscopyy
Emi
p
p
Emission Spectroscopy
Application
Solutions
Absorbance, Transmittance and Reflectance
Detector Spectral Responsivity Measurement
Application Solutions
Fluorescence/Photoluminescence
Fluorescence & Photoluminescence occur when a sample is excited by absorbing photons and then emits them with a decay time
that is characteristic of the sample environment. Fluorescence is a term used by chemists when the absorbing and emitting species
is an atom or molecule. Photoluminescence is the term physicists use to describe the absorption and emission of light by things
such as semiconductors and nanotubes. Regardless of the terminology, when samples absorb photons and then emit them at a
different wavelength the resultant light can be dispersed by a spectrograph, the spectrum can be detected by a device such as a
CCD, and information can be gleaned about the sample
OmniFluo Steady-State Fluorescence/ Photoluminescence System
Application
ȋ
Materials science (wide bandgap semiconductor materials
luminescence properties testing), biology (chlorophyll and carotenoid
testing)
ȋ
Biomedical (fluorescence diagnosis of malignant disease)
ȋ
Environment monitoring
System Performance (Water Raman S/N Ratio: 3128:1)
ϰϬϬϬϬ
ϯϱϬϬϬ
System Specifications
ϯϬϬϬϬ
Modular design, different function perfect combination
to fit your specific needs
ȋ
Extended wavelength range with triple grating
monochromators, 200 nm-2500 nm
Emission spectroscopy correction function
ȋ
High output power, 150W or 500W Xenon light source
ȋ
Different Laser wavelength option, 266nm/325nm/
375nm/405nm/442nm/532nm/785nm/1064nm.
ȋ
Quantum Yield-Expansion option
ȋ
EL-Expansion option
ȋ
Ultralow temperature accessory (Ō10K)
ϮϬϬϬϬ
ϭϱϬϬϬ
ϭϬϬϬϬ
ϱϬϬϬ
Fluorescence/Photoluminescence
ȋ
Sample: purified water
Experimental conditions:
­ex = 350 nm,
Ž­ex = Ž­em = 5 nm,
int = 1 s,
­peak = 397 nm
SN = 3128:1
ϮϱϬϬϬ
Ϭ
ϯϲϬ
ϯϲϰ
ϯϲϴ
ϯϳϮ
ϯϳϲ
ϯϴϬ
ϯϴϰ
ϯϴϴ
ϯϵϮ
ϯϵϲ
ϰϬϬ
ϰϬϰ
ϰϬϴ
ϰϭϮ
ϰϭϲ
ϰϮϬ
ϰϮϰ
ϰϮϴ
ϰϯϮ
ϰϯϲ
ϰϰϬ
ϰϰϰ
ϰϰϴ
ϰϱϮ
ϰϱϲ
ϰϲϬ
ȋ
Water Raman spectrum of the OmniFluo system
Model
OmniFluo
Wavelength Range
200 nm to 2500 nm
Fluorescence Spectral
Resolution
0.1 nm
Excitation Light Source
Tunable Light Source (150W/500W Xenon Light Source with 320mm monochromator)
Excitation Output Bandwidth 0.1 nm to 30 nm
Optional Laser
Optional Detector
Data Acquisition Unit
266 nm/325 nm/375 nm/405 nm/442 nm/532 nm/785 nm/1064 nm
TE-cooled CCD (2000*256)
TE-cooled InGaAs( 512*1)
PhotoMultiplier Tube
TE-cooled InGaAs
200-1000 nm
800-2200 nm
200-870 nm
800-2500 nm
-
-
single photon counting or
lock-in amplifier
lock-in amplifier
Note: Above are the basic configuration, the specification depends on different requirements !
+86 10 56370168 www.zolix.com.cn
53
Application Solutions
System composition
1.Excitation light source: UV to NIR wavelength range light
source or laser.
2.Spectroscopy acquisition: imaging calibration spectrograph/
monochromator, high sensitivity scientific CCD or singlechannel detectors, and data acquisition unit.
3.Sample chamber: solid powders sample holder, ultralow
temperature sample stage and so on.
OmniFluo Fluorescence Basic Configuration
Fluorescence/Photoluminescence
The basic configuration of OmniFluo is for fluorescence spectra
and fluorescence excitation spectra measurement. And this
configuration can be updated to NIR spectral range coverage.
The excitation and emission spectra of rare earth material Ca2YSbO6
1600000
1400000
1200000
1000000
800000
Ex spectra @613nm
600000
Em spectra @286nm
400000
200000
250
276
302
328
354
380
406
432
458
484
505
518
531
544
557
570
583
596
609
622
635
648
661
674
687
700
713
726
739
752
765
778
791
0
54
+86 10 56370168 www.zolix.com.cn
Application Solutions
OmniFluo Photoluminescence(PL) Basic Configuration
OmniFluo Photoluminescence(PL) System can realize the PL/PLE
fluorescence spectra measurement. This system solves the energy
shortage problem effectively for some experiment using Xenon
lamp as the excitation light source. And you can add the sample
temperature controllers for ultralow temperature testing condition,
which is very convenient for rare earth luminescent material luminous
performance research.
Fluorescence/Photoluminescence
Sample Test :
PL&EL of InGaN/GaN, excitation 325nm Laser with 30mW Power , Spectral Range喟340-700nm
(Green curve is PL and red curve is EL)
+86 10 56370168 www.zolix.com.cn
55
Application Solutions
Raman Spectroscopy
Raman spectroscopy is a non-destructive light scattering technique spanning a wide range of scientific and industrial applications.
Most often, Raman spectroscopy is used to characterize or identify the chemical composition and structure of an unknown material.
Incident laser light in the UV, visible or NIR, is scattered inelastically from molecular vibrational modes
OmniRS Modular Raman Spectrometers
OmniRS series Raman spectrometer adopts the modular design,
choose the excellent performance of optical components,
according to the needs of the experiment, the choice of flexible
required components, such as double monochromator, laser,
data acquisition unit, etc., suitable for scientific research
institutes, institutions of higher learning physics laboratory and
chemical laboratory of Raman spectrum and fluorescence
spectrum measurement, simple structure, easy to adjust and
measurement, high sensitivity, good stability.
OmniRS series, the typical architecture of Raman spectroscopy system includes the following several parts: a laser, a spectrometer,
sample chamber and holder (including XYZ adjustable sample holder, level liquid sample holder, solid and powder sample holder,
etc.), CCD, software, a computer, optical table.
OmniRS-532 Modular Raman Spectrometers
OmniRS-532 Modular Raman Spectrometers , using
532 nm wavelength DPSS solid state laser as the
excitation light source, high resolution, low stray light
of long focal length correction spectrometer as a
beam splitter, a notch filter or edge cut-off filter as a
notch filter, using scientific TE cooling CCD as the
Raman Spectroscopy
signal acquisition unit, equipped with a variety of
accessories, applicable to the analysis of the liquid
and solid samples.
OmniRS-Micro Modular Microscopic Raman Spectrometers
OmniRS-Micro system uses microscopic optical
path, compared with the conventional optical path,
the microscopic optical path has a higher collection
efficiency, makes the system has higher sensitivity.
56
+86 10 56370168 www.zolix.com.cn
Application Solutions
Specification*
Model**
Raman Spectral
range
Spectral resolution
OmniRS-532
OmniRS-Micro
-1
200-4,000 cm (Typ.)
Ō5cm-1
Standard: 532nm(100mW, TEM00)
Optional: 488nmȠ632.8nmȠ785nm
Focal length: 500mm, imaging correction, triple grating turret, USB
Laser
Spectrograph
Spectrograph
spectral range
200-2500nm
TE cooling CCD
2000×256
200-1100nm
Detector
PMTH-S1-R1527
200-670nm
Dark counts 100cps
DCS202PC
Photon counter rate :
5Mcps
Data Acquisition Unit -
TE cooling CCD
2000×256
200-1100nm
PMTH-S1-R1527
200-670nm
Dark counts 100cps
DCS202PC
Photon counter rate :
5Mcps
-
Microscopic
-Microscopic optical path
*@532nm ( Tye)
**According to the different measurement requirements, the modular system can have a variety of options, please inquire!
Measurement of Alcohol using OmniRS-Micro, laser 532 nm.
2933.2
x10 3
90
85
80
2882.1
2977.3
2718.6
2756.8
50
1456.9
55
45
500
1 000
1 500
2 000
Wavenumber(cm-1)
2 500
3 000
3 500
+86 10 56370168 www.zolix.com.cn
Raman Spectroscopy
60
1278.5
65
1056.1
1098.5
886.6
70
435.6
Intensity
75
57
Application Solutions
Absorbance, Transmittance and Reflectance
Absorbance is a measure of the amount of light absorbed by a sample as a beam of light passes through it. In this process, a
chemical species is excited from a lower to a higher energy level
Absorbance, transmittance, and reflectance measurements are typically made with.
When choosing a single-point detector, you must first consider the wavelength region to be studied. Photomultiplier tubes (PMTs)
are used in the ultraviolet, silicon detectors in the visible, indium gallium arsenide (InGaAs) and lead sulfide detectors in the nearinfrared region, and mercury cadmium telluride (MCT) in the mid-infrared region. Zolix sells single-point detectors made of each of
these materials.
OmniAS Absorbance, Transmittance and Reflectance Measurement System
Application
Transmission and reflection/absorption is optical element (such
as optical material, filter, coating, etc.) and a variety of life material
(glass,cloth,car sticker etc.) important indicators. The optical
properties of OmniAS transmission and reflection/absorption spectra
measurement system is aimed at the application requirement, the
design of high integration, automated measurement system, it can
help developers easily and fast in the laboratory QC or complete
transmission/reflection spectral testing.
A generic absorbance/transmittance or reflectance measurement system consists of:
ȋ
light source
ȋ
Monochromator
ȋ
Filter wheel
ȋ
Sample chamber or system (such as a fiber optic probe)
ȋ
Detection system
Other options are available upon request.
Absorbance, Transmittance and
Reflectance
Omni-DR300 Solid Powder Diffuse Reflectance Measurement System
58
This system adopts the wide band wavelength tunable
monochromatic light source and integrating sphere, downlooking configurations, sample stage for small drawer sample box,
convenient to place the powder samples, easy to replace.
ȋ
Spectral range: 350-2500nm
ȋ
Spectral resolution: 2nm
ȋ
Step: 0.2-100nm
ȋ
Wavelength Accuracy: d0.2nm(UV, visible), d0.5nm(NIR)
ȋ
Photometric measurement accuracy: 1%(UV, visible), 2%(NIR)
ȋ
Photometric measurement repeatability: 1%
ȋ
Testing optical axis and the sample Angle:<10c
ȋ
Sample size (typ.): Ø10(D) *3(H)(mm)
+86 10 56370168 www.zolix.com.cn
Application Solutions
Omni-DR600 Plane Material Diffuse Reflectance & Transmittance Measurement System
This system adopts the wide band wavelength tunable
monochromatic light source and integrating sphere, up-looking
configurations(8cfocusing). Sample stage is 160 * 160 mm,
convenient placement of all kinds of plane object for testing, such as
all kinds of functional fabric. At the same time, the system integration
of the transmittance measurement probe, can measure all kinds of
pervious to light material (thickness less 5 mm).
ȋ
Spectral range: 350-2500nm
ȋ
Spectral resolution: 2nm
ȋ
Step: 0.2-100nm
ȋ
Wavelength Accuracy: d0.2nm(UV, visible), d0.5nm(NIR)
ȋ
Photometric measurement accuracy: 1%(UV, visible), 2%(NIR)
ȋ
Photometric measurement repeatability: 1% (450nm-1800nm)
ȋ
Testing optical axis and the sample Angle:<10c
ȋ
Sample size (typ.): Diameter>15mm, thickness less 5 mm for
transmittance measurement
Sample Test
Spectral range: 380-800nm, Bandwidth: 5nm,
Grating: 1200g/mm 300nm
Optical Lens Transmittance
Measurement System
Goggles Spectral & Integral Transmittance
Measurement System
+86 10 56370168 www.zolix.com.cn
Absorbance, Transmittance and
Reflectance
Reflectivity curve of perovskite sample
59
Application Solutions
Emission Spectroscopy
Light, such as incandescent lamp, fluorescent lamp, LED radiation spectrum and luminescence properties testing, is of great help
to study its characteristics. Emission Spectroscopy measurement system not only can measure light source or other emission
spectrum distribution, and can be obtained on the basis of the integral radiation flux, luminous flux and color coordinate, etc.
According to different characteristics of the radiation source, flexible choice test system, such as: broadband light source and LED
often requires resolution is not high, it is recommended to use short focal length spectrometer/monochromator. Lasers, discharge,
plasma, atomic emission spectrum, such as high resolution requirements, recommend the use of long focal length spectrometer/
monochromator. Wide wavelength range (UV to the IR), the proposal uses double monochromator exports meet two detectors. Test
wide spectrum light, need to use SD filter wheel multistage spectrum.
System composition: spectroscopic system + detection system, data acquisition and processing system + computer system
and software system.
Emission Spectroscopy
OmniES-Scanning Emission Spectrum Measurement System
60
OmniES-Spectrographic Emission Spectrum Measurement System
+86 10 56370168 www.zolix.com.cn
Application Solutions
Detector Spectral Responsivity Measurement
Photodetector is the sensor that could convert the optical radiation signal to the electrical signal, which is made from photoemission
material. Most of the photodetectors have strong spectral selectivity in a certain Spectrum area. Therefore, for one photodetector,
different wavelengths have different spectral responsivity. The spectral responsivity is an important parameter index for characterizing
the photodetector performance.
And for the photoelectric material researching , the effect of some characteristics of the material itself such as doping density, lattice
imperfection, absorption coefficient and minority carrier diffusion length on the photoelectric response capacity and the quantum
efficiency could be obtained by measuring and analyzing the spectral responsivity data. That is very important and helpful for
choosing better material and processing improvement.
DSR100 Detector Responsivity Measurement System
System Specifications
Application
ȋ
DUV detector
ȋ
Solar cell detector
ȋ
Optical fiber sensor
ȋ
IR photoelectric sensor
DSR100-X150A-A
200~2500nm
Light source
UV enhanced
Xenon light source
Repeatability*1
200~450 nm
450~1800nm
1.8~2.5 μm
2~6 μm
6~14 μm
Optical
Spot
Ō 2%
Ō 1%
Ō 2.5%
-
DSR100-T75SiN40-A
350~14μm
Tungsten-halogen
lamp and silicon nitride
light source
Ō 1%
Ō 1%
Ō 3%
-
Ō 5%
UV enhanced
Ō ĭ1 mm
Silvering
Ō ĭ1 mm
*1. Repeatability data is provided when the peak wavelength signal intensity is
closing to the saturation value of the detector, and there are different standard
detectors to cover the different wavelength range.
Standard Reference Detector Accessories
Model
DSR-A1
DSR-A7
DSR-T1
DSR-T2
DSR-A2
DSR-A8
Wavelength Range
200~1100 nm
300~1100 nm
350~1000 nm
800~1800 nm
800~2500 nm
1~14 μm
Detector Spectral
Responsivity Measurement
System Size
Model
Wavelength Range
Calibrated by
National Institute of Metrology, China
National Institute of Metrology, China
NIST-traceable NIST-traceable Xi 'an Institute of Applied Optics, China
Xi 'an Institute of Applied Optics, China
+86 10 56370168 www.zolix.com.cn
61
Application Solutions
Sample Test
Si Detector
Wavelength spacing: 10nm
Bias voltage: 1V
Chopper frequency: 330 Hz
Responsivity
Wavelength range: 200-2500nm
Wavelength(nm)
System Benefits
ȑWide wavelength range (200~14000 nm, optional),
ȑHigh stability light source, reducing the background noise.
widely applicable
ȑTurnkey system, Easy maintenance.
The system uses substitution method of measuring
principle, which is designed into Turnkey mode. Users
do not need to debug the system before experiments.
Routine maintenance is also very simple.
ȑCCD monitoring optical path for sample location.
Detector Spectral
Responsivity Measurement
The detectors with very small area can be located
62
precisely by the system.
ȑperfect reflection optical design, optimization of spot
quality
ȑData export format supports third- party software.
the perfect reflection optical system, you can get the
DSR100 can save all original data, and the experimenter can
quality parallel spot or much small convergency spot.
save the data as the *.txt, *. *.xls* and so on.
+86 10 56370168 www.zolix.com.cn
Application Solutions
Solar Cell Testing & Characterization
Omni-Station Perovskite & DSSC IPCE Measurement System
Samples:
Si, mc-Si, £-Si, GaAs, GaInP, InP, Ge, CdTe, CIS, CIGS, DSSC,
Organic Solar Cell, Polymer Solar Cell, Perovskite Solar Cell and
so on.
Function:
External Quatum Effieciency, Internal Quatum Effieciency,
Spectral Responsivity, Transmittance, reflectivity, Jsc.
Features:
ȋ
Spectral range: 300~1100 nm
ȋ
Measurement items: Spectral responsivity, QE,Short circuit
current density.
ȋ
Sample: 100x100 mm
ȋ
Measurement: DC, DC with bias light;
ȋ
AC measurement mode as option
ȋ
Mapping function as option
Solar Cell Testing &
Characterization
Note:
Green AC(3.8Hz)+0.1Sun bias light
Blue DC without bias light
Red DC+0.1Sun bias ight
System Configuration
+86 10 56370168 www.zolix.com.cn
63
Application Solutions
System Performance
Repeatability 喟 300~400nm <0.6%喠400~1000nm <0.3%喠Above 1000nm <0.6%
All wavelength repeatability test
Sample Test
Crystalline silicon Solar Cell measurement
Measurement items: Spectral responsivity, EQE & IQE, Reflectivity,
Short circuit current density.
ȋ
Sample description: Crystalline silicon Solar Cell 156 x 156 mm
ȋ
Spectral range: 300~1100 nm
ȋ
Light spot: Ÿ10 mm
Solar Cell Testing &
Characterization
ȋ
Time constant:100 ms
ȋ
Ambient temperature: 25d1Ď
ȋ
Mapping measurement: Room temperature, step 1 mm. Scanning
time 5 min, testing wavelength 550 nm.
a-Si Solar Cell measurement
ȋ
Spectral range: 300~1100 nm
ȋ
Light spot diameter Ÿ2.5 mm
ȋ
64
Frequency: 170Hz
ȋ
Frequency: 180Hz
ȋ
Time constant: 300 ms
ȋ
Blue, red bias light
ȋ
Ambient temperature: 25±1Ď
ȋ
Measurement items: p-n Junction EQE, Short circuit current
density.
+86 10 56370168 www.zolix.com.cn
5 times test results, each time interval for an hour
Application Solutions
Dye Sensitized Solar Cell Measurement
ȋ
Sample: DSSC, 10 x 10 mm
ȋ
Spectral range: 300~800 nm
ȋ
Light spot: diameter Ÿ1.5 mm
ȋ
DC Mode
ȋ
Ambient temperature: 25±1Ď
ȋ
Measurement items: IPCE, Spectral responsivity
Specifications
Specification
Light Spot
2-10mm
Wavelength Range
300-1100nm
Step
Min.0.1nm, recommend 5nm
Filter Wheel
Automatic switching according to the wavelength
Calibration Detector
Calibrated silicon detector
Data Acquisition Sensitivity
100nA
Sample Holder
Suit for Sandwich DSSC
Optical Table Size
≥1200mmx800mm
PC and Software
Win7 system and Setup software
Solar Cell Testing &
Characterization
+86 10 56370168 www.zolix.com.cn
65
Application Solutions
Solar Simulator
Solar simulators provide a broadband spectrum close to that of the sun from
the UV to the IR. The main part of the solar simulator is a xenon arc lamp that
reaches a color temperature of approximately 6000 K which is very close to sun
light.
The main application of our solar simulator systems is the evaluation of power
parameters of solar cells. For this type of measurements, the solar simulator is
integrated into an IV measuring station. For setting the correct irradiance value
we offer calibrated reference cells.
Further applications are the determination of Measurements can be made on a
wide range of solar cell materials, such as: Monocrystal silicon, polycrystalline
silicon, £-Si, GaAs, GaInP, InP, Ge, CdTe, CIS, CIGS, DSSC, Organic Solar Cell,
Polymer Solar Cell.
In addition the system is also applicable for a variety of solar cell structures, for
Solar Simulator
Ordering information:
Model
Description
150 W AAA class solar simulator,
1000W/m2, 40mm Illumination diameter
Sirius-SS150A
light direction is up
Sirius-SS150A-D light direction is down
Sirius-SS150A-L
light direction is left
Sirius-SS150A-R
light direction is right
150 W ABA class solar simulator,
1000W/m2, 50mm Illumination diameter
Sirius-SS150
light direction is up
Sirius-SS150-D
light direction is down
Sirius-SS150-L
light direction is left
Sirius-SS150-R
light direction is right
500W AAA class solar simulator,
1000W/m2, 75mm Illumination diameter
Sirius-SS500A
light direction is up
Sirius-SS500A-D light direction is down
Sirius-SS500A-L
light direction is left
Sirius-SS500A-R
light direction is right
500W ABA class solar simulator,
1000W/m2, 100mm Illumination diameter
Sirius-SS500
light direction is up
Sirius-SS500-D
light direction is down
Sirius-SS500-L
light direction is left
Sirius-SS500-R
light direction is right
1000W AAA class solar simulator,
1000W/m2, 100mm Illumination diameter
Sirius-SS1000A
light direction is up
Sirius-SS1000A-D light direction is down
Sirius-SS1000A-L light direction is left
Sirius-SS1000A-R light direction is right
1000W ABA class solar simulator,
1000W/m2, 150mm Illumination diameter
Sirius-SS1000
light direction is up
Sirius-SS1000-D
light direction is down
Sirius-SS1000-L
light direction is left
Sirius-SS1000-R
light direction is right
example: Single junction, multi-junction, HIT, thin film, HPV and so on.
According to European ICE 60904-9 norm, solar simulators are tested for 3
different criteria and classified for each criterion into class A,B, or C. This results
in a classification of the complete solar simulator, for example AAA or ABA. The
criteria being tested are spectral match, non-uniformity and temporal stability of
the light.
The main application of our solar simulator systems is the evaluation of power
parameters of solar cells. For this type of measurements,the solar simulator is
integrated into an IV measuring station. For setting the correct irradiance value
we offer calibrated reference cells.
Further applications are the determination of plant growth, characterization of
transparent components like sun protection glasses or the development of skin
care products.
Spectral range (nm)
400-500
500-600
600-700
700-800
800-900
900-1100
Irradiance range (%)
13.9-23.1
15.1-25.1
13.7-22.9
11.1-18.5
9.2-15.3
12.1-20.1
Irradiance (%)
18.5
20.1
18.3
14.8
12.2
16.1
Note: Please specify illumination direction
Sirius-SS150A-D 150W
66
+86 10 56370168 www.zolix.com.cn
Sirius-SS150A
Sirius-SS150A-L
Application Solutions
Photocatalysis
Sirius-300P 300W Photocatalysis Light Source
ȋ
High effective parabolic condenser ensure high collimation and high
energy output
ȋ
The light height can be adjustable according to customer's requirement
ȋ
Light Source can be used as whole system or separately( housing and
power supply can be divided into separate parts)
ȋ
The power supply can be turned off automatically by setting time
ȋ
High effective air-cooling has improved bulb lifetime
ȋ
High stability,unstability degree1°
Relative Spectral Distribution
Sirius-300P series photocatalysis light source has
high output from UV to NIR, Sirius-300P-F focus
on simulated sunlight of visible light; Sirius-300P-
Spectral curve as right picture:
Relative intensity
UV has strong continuous output within 200-400nm
and focus on applications of high UV requirements.
Specification
Sirius-300P
Sirius-300PU
Power Supply Voltage
AC190~240V 50Hz FUSE~5A
AC190~240V 50Hz FUSE~5A
Rated Power
300W(180~320W)
300W(180W~320W)
Current
DC 21A(10A~22A)
DC 21A(10A~22A)
Voltage
DC 14V(13~16V)
DC 14V(13~16V)
Output Power
50W
50W
Spectral Range
320~2500nm
200~2500nm
Output Powe(UV)390nm(Watts)
2.6W
6.6W
Output Powe(IR) 770nm(Watts)
28.8
26.8
Output Power(VIS) 390-770nm(Lumens)
5000Lu
4500Lu
Power Intensity
[email protected]
[email protected]
Color Temperature
5600K
5050K
Bean Diameter
50mm adjustable
50mm adjustable
Divergence Angle of Parallel Light
Average 5°
Average 5°
Center Height of Output Light
70-220mm adjustable
70-220mm adjustable
Bulb Life(Hours)
1000H to 6000H
1000H to 6000H
Size
341mmx244mmx290mm
341mmx244mmx290mm
Weight(Kg)
11Kg
11Kg
+86 10 56370168 www.zolix.com.cn
Photocatalysis
Parameters
67
Application Solutions
Application:
ఫ❴Გ⎽λ㑾㐉
Photocatalysis, industrial catalysis, hydrogen aquatic
photolysis, photochemical catalysis, photochemistry synthesis,
optical degradation of pollutants, water pollution treatment,
biological light, optical detection, various accelerated test
simulated sunlight visible, ultraviolet band accelerated test and
other research areas.
Safety Tips
Automatic power off after open the cover
The system will automatic power off if the cover of power supply/housing is opended by man-made,it ensure user's safety.
Overheating protection function
The system will automatic power off when the housing temperature over safety,ensure lamp will work within safe condition and
prolong life.
Trigger protection function
The system will ban on lighting if light is not successful trigger for ten seconds .Avoid long time continuous frequent light caused
damage of trigger and bulb.
Bulb life tips
Most electric energy transform to heat when the bulb output attenuation is too large,bulb explosion danger is exist. Sirius300P can
check bulb condition and give tips for customer to change bulb when it is danger.
Photocatalysis
Light Source Accessories
Lens Holder
Filter Holder
Beam-Splitting Component
68
Iris Diagramph
Light Path Sealing Component
+86 10 56370168 www.zolix.com.cn
Beam Steering Component
Fiber Coupling Component
As a manufacturer, we also have complete sets of scientific instruments and Opto-mechanics in addition to
spectrographs, light sources, detectors etc. List of pictures as reference, welcome to contact us if you are
interested in further information !
Laser Confocal Raman Microspectrometer
Microscope Photoluminescence Spectrometer
---Finder Vista
---Flex One
Solid Damping Vibration Isolation Optical Table
Pneumatic Vibration Isolation Optical Table
Motorized/Manual Stage
Kinematic Mirror Mount
+86 10 56370168 www.zolix.com.cn
69
www.zolix.com.cn
Zolix Instruments Co.,Ltd.
Address: No.68B LDUV, Tongzhou District, Beijing, China 101102
Tel: +86 10 56370168
Fax: +86 10 56370118
Email : [email protected]
All right reserved
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement