Handwind 43
 Handwind 43
Operational Manual
TVL No.282
Issue No. 9
23/01/09
Thames Valley Controls | Unit 15 | Manor Farm Industrial Estate | Flint | Flintshire | CH6 5UY | T: +44 (0) 1352 793222 | F: +44 (0) 1352 793255 | info@tvcl.co.uk
CONTENTS
1
Introduction .......................................................................................................... 3
2
Enclosure Layout ................................................................................................. 3
3
Application ........................................................................................................... 3
4
SE500 External Terminal Designations. .............................................................. 7
5
Tape Head Version Terminal Designations ......................................................... 7
6
VCOM Version Terminal Designations ................................................................ 7
7
Internal DDU Terminal Designations. .................................................................. 8
8
Visual Display Messages ..................................................................................... 8
9
Audible Messages ............................................................................................. 10
10
Option Configuration .......................................................................................... 10
11
Position Reset.................................................................................................... 11
12
Leveller/Tape Head Switch Layout .................................................................... 11
13
General Specification. ........................................................................................ 12
Page 2 of 12
TVL282
ISSUE 9
23/01/09
1
Introduction
The hand winding display unit from TVC, is a stand-alone positional tracking device, intended to audibly
and visually report the position and floor level status under hand winding operation.
This unit includes the battery backed supply, battery charger, and DDU display unit, housed in one
enclosure.
Positional tracking is performed by monitoring the floor level and reset switches, under hand wind
operation, battery power is diverted through the existing tape head switches.
2
Enclosure Layout
3
Application
This section describes the three different types of application. The first being the tape head application,
which as its name suggests, allows the handwind display to be controlled via existing tape head unit or
proximity switches of many kinds.
The second application within this manual describes the application of the hand wind unit to an existing
TVC controller utilising the SE500 shaft encoder.
The third application within this manual describes the application of the hand wind unit to an existing TVC
controller utilising the ETHOS VCOM encoder.
Page 3 of 12
TVL282
ISSUE 9
23/01/09
3.1 Tape Head Application
This application uses existing volt free contact switches or tape head contacts to signal the hand wind unit
of floor level status, this works by diverting your existing tape head signals into the hand wind unit, which
then creates a duplicate set of contacts through pilot relays, which are then fed back to the control
system.
Beware of power inductor type switches, which require mains voltages, which won’t be present during
power down situations.
3.1.1
Tape Head Application
Page 4 of 12
TVL282
ISSUE 9
23/01/09
3.2 SE500 Application.
This drawing depicts the application of a hand wind unit to an existing TVC controller utilising the SE500
shaft encoder.
Page 5 of 12
TVL282
ISSUE 9
23/01/09
3.3 ETHOS VCOM Application.
This drawing depicts the application of a hand wind unit to an existing TVC controller utilising the Ethos
VCOM encoder.
Page 6 of 12
TVL282
ISSUE 9
23/01/09
4
SE500 External Terminal Designations.
Terminal
L
N
E
HW1
HW2
H+
HH3
H4
H5
H6
H7
H8
5
Voltage
230Vac
110Vac
Tape Head Version Terminal Designations
Terminal
L
N
E
HW1
HW2
LL
LU
LD
H+
HH3
H4
H6
6
Description
Single Phase Supply Live
Single Phase Supply
Neutral
Single Phase Supply Earth
Safety Circuit Feed
Safety Circuit Return
24Vdc Supply
24Vdc return
SA signal
SB Signal
SDZ Signal
Bottom Floor Reset
UP Signal
Down Signal
Description
Single Phase Supply Live
Single Phase Supply
Neutral
Single Phase Supply Earth
Safety Circuit Feed
Safety Circuit Return
Leveller Common
UP Leveller
Down Leveller
24Vdc Supply
24Vdc return
Up Leveller Proximity
Down Leveller Proximity
Bottom Floor Reset
Voltage
230Vac
110Vac
Volt Free Contact to
Controller
12-24Vdc
VCOM Version Terminal Designations
Terminal
L
N
E
HW1
HW2
H+
HH5
H6
H7
Description
Single Phase Supply Live
Single Phase Supply
Neutral
Single Phase Supply Earth
Safety Circuit Feed
Safety Circuit Return
24Vdc Supply
24Vdc return
DZF Signal
Bottom Floor Reset
Direction Signal
Voltage
230Vac
110Vac
Page 7 of 12
TVL282
ISSUE 9
23/01/09
7
Internal DDU Terminal Designations.
Terminal
P1
P2
OV
DIN
1
2
3
6
7
Name
P1
P2
OV
DIN
MON
HW
LU
SA
LD
SB
SDZ
DZF
BFR
UP
8
9
10
R
DN
Spare
Spare
R
4
5
Description
Display DC Supply
Display DC Supply
Display Ground
Unused
Supply monitor (unused)
Hand-wind Input
TAPEHEAD Levelling Up
SE500
TAPEHEAD Levelling Down
SE500
SE500 Shaft Encoder Door Zone
VCOM Door Zone
Bottom Floor Reset
SE500 UP Signal
VCOM Direction Signal
SE500 DN Signal
Spare
Spare
Input Common Return
Voltage
12Vdc-24Vdc
GND
8 Visual Display Messages
There are three types of display messages, Hand-Wind/Normal, Reset Messages and Floor position
messages, these messages are constantly rotated and re-cycled depending upon their respective input
configuration.
8.1 Hand-Wind / Normal Messages
There are two operating modes, Normal and Hand-Wind, the selection of which depends upon the status
of input HW on the electronics display unit.
Operating Mode
Normal
Hand-Wind
HW
OFF
ON
Display Message
Normal Supply
Lift on Hand-Wind
8.2 Reset Signal Messages.
The reset signal BFR synchronise the internal selector positions, and are reported on the message
display when active.
Operating Mode
Hand-Wind/ Normal
Active Reset
BFR
Display Message
on Bottom Floor Reset
Page 8 of 12
TVL282
ISSUE 9
23/01/09
8.3 Floor Level Messages.
The floor level messages will be displayed depending upon the input signals LU, LD & SDZ, although
SDZ is reserved for applications with an SE500 Shaft Encoder system and DZF for VCOM applications.
Operating Mode
Hand-Wind/Normal
Hand-Wind/Normal
Hand-Wind/Normal
Hand-Wind/Normal
Hand-Wind/Normal
Hand-Wind/Normal
Hand-Wind/Normal
LU
OFF
ON
ON
OFF
OFF
OFF
X
LD
ON
OFF
ON
OFF
OFF
OFF
X
SDZ/DZF
X
X
X
X
X
X
ON
Display Message
Just Above Level
Just Below Level
At Floor Level
Between Levels
Between Levels-Up
Between Levels-Down
In Door Zone
Audible
Silent
Silent
Sound
Silent
Silent
Silent
Silent
8.4 Floor Position Display.
The floor position characters have been pre-programmed during manufacture of this device; contact
Liftstore Ltd for modifications to the floor characters.
“XX” will be displayed in the floor position display when the position is unknown, the position is unknown
when the unit is powered for the first time, or when the mains power and battery have been removed or
exhausted.
The position will automatically update when the position is synchronised by the assertion of the bottom
floor reset, BFR.
If the parameter dipswitch SW1.4 is set to ON, position display will be allowed to show inverse video
whilst at floor level.
8.5 Selector Stepping Sequence
The floor leveller switches are used in this application to automatically step the internal electronic
selector.
Once a sequence has been triggered by the assertion of a floor level signal, the sequence will only
terminate when both leveller switches become inactive, then the sequence can start again.
UP Sequence
1
2
3
LU
OFF
ON
ON
LD
OFF
OFF
ON
Action
Clear Inhibit Step
Set Position for up direction
Step Floor Position +1, Set Inhibit.
Down Sequence
1
2
3
LU
OFF
OFF
ON
LD
OFF
ON
ON
Action
Clear Inhibit Step
Set Position for down direction
Step Floor Position -1, Set Inhibit.
Note: - See Leveller Switch Layout for more details.
Page 9 of 12
TVL282
ISSUE 9
23/01/09
9 Audible Messages
The Hand-Winding unit has been fitted with an Audible device, this device will sound if the unit is on hand
winding mode, and is within door zone.
Operating Mode
Hand-Wind
Hand-Wind
Hand-Wind
Hand-Wind
Hand-Wind
Hand-Wind
Hand-Wind
LU
OFF
ON
ON
OFF
OFF
OFF
X
LD
ON
OFF
ON
OFF
OFF
OFF
X
SDZ/DZF
X
X
X
X
X
X
ON
Display Message
Just Above Level
Just Below Level
At Floor Level
Between Levels
Between Levels-Up
Between Levels-Down
In Door Zone
Audible
Silent
Silent
Sound
Silent
Silent
Silent
Sound
10 Option Configuration
This unit has been fitted with a number of option dipswitches, these dip switches are located on the
reverse of this electronic display unit. The configuration will depend on the software version fitted to the
unit. Changes to the settings will only take place after a full system power down and reset.
Software version HW43-3-5 onwards
The dipswitch settings are as follows: DIP
SW1
SW1.1
SW1.2
SW1.3
SW1.4
SW1.5
SW1.6
SW1.7
SW1.8
Set to ON
Set to OFF
VCOM Encoder System Fitted
Demo Mode
Inverted Position Resets
Top Floor + 1
Top Floor + 2
Top Floor + 4
Top Floor + 8
Top Floor + 16
Normal LU/LD Selector Stepping.
Not Demo Mode
Normal Position Resets
Software version prior to HW43-3-5
The dipswitch settings are as follows: DIP
SW1
SW1.1
SW1.2
SW1.3
SW1.4
SW1.5
SW1.6
SW1.7
SW1.8
Set to ON
Set to OFF
SE500/VCOM Encoder System
Fitted
Inverted Position Resets
Scroll Floor Number
Reverse Video at Floor Level
Top Floor + 1
Top Floor + 2
Top Floor + 4
Top Floor + 8
Normal LU/LD Selector Stepping.
Normal Position Resets
No Scroll
Normal Screen at Floor Level
For all software versions Top Floor setting starts at 2 so that by setting the Top Floor dip switches you are
adding from the base of 2.
Page 10 of 12
TVL282
ISSUE 9
23/01/09
To reset the new dipswitch settings, remove and replace JP1 on the electronic display module.
11 Position Reset.
The position-reset input BFR (bottom floor reset), becoming active forces the position to the preprogrammed bottom floor position and inhibits the selector stepping function.
Selecting the appropriate dipswitch to the ON position will enable normally closed reset limits operation.
12 Leveller/Tape Head Switch Layout
Page 11 of 12
TVL282
ISSUE 9
23/01/09
13 General Specification.
Section
Input Voltages
Supply Voltage
Configuration
Display
Battery Voltage
Battery Capacity
Battery Life
Battery Charging Voltage
Fuses
Description
9-30Vdc
230Vac
Via Dipswitches
Split Screen between messages and position.
Horizontal Mode Only
Two digital positional display
Programmable Positions
12Vdc
1.2Ah
3-4 Hours depending upon messages.
13.8Vdc
F1=1A 20mm.
Page 12 of 12
TVL282
ISSUE 9
23/01/09