METRACLIP 62 Clip-On Ammeter for the Measurement of Leakage

METRACLIP  62 Clip-On Ammeter for the Measurement of Leakage
METRACLIP62
Clip-On Ammeter for the Measurement of
Leakage and Charging Current
3-349-392-03
2/3.10
•
•
•
•
•
•
•
•
•
3 measuring ranges 1 mA . . . 10 A AC TRMS / DC
High resolution due to hall effect sensor
Switch-over between DC and AC measurements
Zero balancing for DC measurements
Storage of reference values for AC measurements
Display of maximum or minimum current measured value
Storage of measured value (DATA HOLD)
Battery saving circuit
Insensitive to magnetic interference fields thanks to double
shielding
Applications
Characteristic Values
•
•
Measuring sensor
•
•
Measurement of leakage current at grounded conductors
Measurement of leakage current
at single-phase or 3-phase systems
Measurement of line current
Measurement of charging current
Hall effect
Measuring Ranges
Meas. Range
Input
Resolution
Accuracy at 18 ... 28 C,
max. 80% relative
humidity
A AC TRMS with automatic zero balancing
Applicable Regulations and Standards
Safety requirements for electrical equipment for
IEC 61010-1/EN 61010-1/
measurement, control and laboratory use
VDE 0411-1
– General requirements
EN 60529
VDE 0470 Part 1
Test instruments and test methods
Degrees of protection provided by enclosures (IP code)
DIN EN 61326
VDE 0843 Part 20
Electrical equipment for measurement, control and
laboratory use – EMC requirements
200 mA
0  199.9 mA
100 A
1.0% rdg. 5 digits 1)
2000 mA
0  1999 mA
1 mA
1.0% rdg. 5 digits 1)
10 A
0  9.99 A
0.01 A
1.0% rdg. 10 digits 1)
A DC with automatic zero balancing
1)
2)
200 mA
0  199.9 mA
100 A
1.0% rdg. 3 digits 2)
2000 mA
0  1999 mA
1 mA
1.0% rdg. 3 digits 2)
10 A
0  9.99 A
0.01 A
1.0% rdg. 10 digits 2)
Frequency range: 50  60 Hz, corner frequency 2 kHz
additional error for hall effect due to hysteresis: 3% rdg.
Key: rdg. = measured value (reading)
Reference Conditions
Ambient temperature
relative humidity
GMC-I Messtechnik GmbH
+23 C 5 C
max. 80%
METRACLIP62
Clip-On Ammeter for the Measurement of
Leakage and Charging Current
LCD
Display
Number of places
Sampling rate
Overflow display
Display for DATA HOLD
Mechanical Design
7-segment characters
3½ digits, max. display 1999
Digital display: 1.6/s
OL appears
DH appears
Clip opening
Dimensions
Weight
max. dia. 18 mm
W x H x D: 76 mm x 194 mm x 30 mm
approx. 350 g with batteries
Standard Equipment
Power Supply
Batteries
Service life
Battery test
Automatic
shutdown
2 x LR6 (AA size)
with alkaline-manganese batteries:
approx. 120 hours
Symbol B is displayed automatically
if battery voltage is too low
the device turns itself off automatically
10 minutes after it has been switched on.
Electrical Safety
Dielectric strength
Measuring category
2.3 kV AC max. 1 min between the clip
jaws and the exposed clip housing
300 V CAT III 10 A
Electromagnetic Compatibility (EMC)
Interference emission/
interference immunity IEC 61326
Ambient Conditions
Operating
temperatures
0 C  +50 C
< 80% humidity
(no condensation allowed)
Storage temperatures 20 C  +60 C
< 75% humidity
(no condensation allowed)
(without batteries)
Edited in Germany • Subject to change without notice • A pdf version is available on the internet
GMC-I Messtechnik GmbH
Südwestpark 15
90449 Nürnberg • Germany
Phone +49 911-8602-111
Fax
+49 911-8602-777
E-Mail info@gossenmetrawatt.com
www.gossenmetrawatt.com
1
1
1
1
Clip-on ammeter
Imitation leather bag
Set of batteries
Operating instructions
Order Information
Description
Type
Article number
Digital clip-on ammeter
METRACLIP62
M311F
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising