Model R2007 - Global Test Supply

Model R2007 - Global Test Supply
Black
Model R2007
Dual Laser Infrared
Thermometer
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Instruction
Manual
www
Find Quality Products Online at:
reedinstruments
www.
GlobalTestSupply.com
com
sales@GlobalTestSupply.com
Table Of Contents
Safety.......................................................................................................... 2
Features....................................................................................................... 3
Specifications.............................................................................................. 3
Notes........................................................................................................... 4
Distance & Spot Size................................................................................... 4
Instrument Description................................................................................ 5
Display Description..................................................................................... 5
Operating Instructions..............................................................................5-8
Applications........................................................................................... 6
MODE Button Function......................................................................... 6
Switching Settings................................................................................. 6
Cleaning................................................................................................ 7
Notes..................................................................................................... 7
Emissivity............................................................................................7-8
Battery Replacement................................................................................... 8
Safety
• Use extreme caution when
the laser beam is turned on
• Do not let the beam enter your eye,
another person’s eye or the eye of an animal
• Be careful not to point the beam off a reflective surface & into your eye
• Do not allow the laser light beam to impinge on any gas
which can explode
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
2
sales@GlobalTestSupply.com
Features
• Dual lasers assist with target area identification
• 50:1 distance to spot size ratio
• Digitally adjustable emissivity
• High and low alarms
• Max, Min, Avg and Differential readings
• Internal memory saves last 9 data points automatically
• Backlit display
• User selectable °F or °C
• Built-in dual laser pointers identify target area
• Low battery indicaton and auto shut off
Specifications
Temperature Range
-58 to 2012°F (-50°C to 1100°C)
Accuracy
±2% of reading or 4°F (2°C)
Resolution
0.1°C or 0.1°F
Optical Resolution
50:1
Laser Target Selection
Dual Laser
Spectral Response
8-14 µm
Emissivity
0.1 to 1.0 (Adjustable)
Response Time
500ms
Power Supply
9V Battery
Operating Temp. Range 32 to 122 °F (0 to 50 °C)
Operating Humidity Range
10-90%
Dimensions
4.8 x 17.6 x 10.3cm (1.89 x 6.93 x 4.06”)
197g (7.0oz)
Soft carrying case and battery
Weight
Included
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Pantone 534 Blue
Black
Blue - 100/80/30/5
Yellow - 0/27/100/0
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
3
sales@GlobalTestSupply.com
Notes
• Do not use solvent to clean lens
• Do not submerge the unit in water
• Not recommended for measuring shiny or polished metal surfaces
(stainless steel, aluminum, etc)
• This meter cannot measure through transparent surfaces, it will
measure the surface temperature
• Steam, dust, and smoke can prevent accurate measurement by
obstructing the unit’s optics
Distance & Spot Size
Distance et dimension (D) du point de saisie (S)
As the distance (D) from the object increases, the spot size (S) of the area
measured by the unit becomes larger. The relationship between distance
and spot size for each unit is listed above.
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
4
sales@GlobalTestSupply.com
Instrument Description
1. LCD display
2. Laser/Backlight/°C/°F
button
3. Mode button
4. buttons
5. Battery cover
6. Trigger
7. Dual lasers
8. Infrared lens
Display Description
1. Data hold
2. Laser signal
3. Low battery indicator
4. Data recall
5. Current temperature reading
6. Setting display
7. High temperature alarm
8. Low temperature alarm
9. Maximum measurement
10.Minimum measurement
11.Average measurement
12.Difference measurement
13.Emissivity setting
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Operating Instructions
1. Hold the meter and point it toward the surface to be measured.
2. Pull and hold the Trigger to turn the meter on and begin measuring,
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
5
sales@GlobalTestSupply.com
the temperature reading will automatically show on the LCD screen.
3. Release the Trigger and the HOLD display icon will appear on the
LCD indicating that the current measurement is being held on the
screen. For continuous testing hold the button down.
4. The meter will automatically power down after approximately 15
seconds of inactivity.
Applications
Applications for this product include food preparation, safety and fire
inspectors, plastic molding, asphalt, marine and screen printing, measure
ink and dryer temperature, HVAC/R, diesel, fleet maintenance and
much more.
MODE Button Function
HAL
LAL
MAX
MODE
MIN
AVG
DIF
EMS
This infrared thermometer measures Maximum (MAX), Minimum (MIN), Differential (DIF), and Average (AVG) Temperatures. Each time you take a reading, the last nine (9) readings
are stored and can be recalled by pressing and holding the
MODE button. When the trigger is pulled again, the unit will
begin measuring in the last mode selected. Pressing the
MODE button also allows you to access the High Alarm
(HAL), Low Alarm (LAL) & Emissivity (EMS). Each time you
press MODE, you advance through the mode cycle. The
diagram on the left shows the sequence of functions in the
MODE cycle.
Switching Settings
Select the temperature units (°C or °F) by pressing and holding down the
backlight / laser / °C / °F (button #2 on instrument diagram).
To set values for the High Alarm (HAL), Low Alarm (LAL) and Emissivity (EMS), firstly activate the display by pulling the trigger or pressing
the MODE button, then press the MODE button until the appropriate
selection appears in the lower left corner of the display, press the UP and
DOWN buttons to adjust the desired values.
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
6
sales@GlobalTestSupply.com
Cleaning
Periodically wipe the case with a dry cloth. Don’t use abrasives or solvents on this instrument
Notes
How it Works
This REED Infrared Thermometer measures the surface temperature of an
object. The unit’s optics sense emitted, reflected, and transmitted energy
which is collected and focused onto a detector. The unit’s electronics
translate the information into a temperature reading which is displayed on
the unit. In units with a laser, the laser is used for aiming purposes only.
Field of View
Make sure that the target is larger than the unit’s spot size. The smaller
the target, the closer you should be to it. When accuracy is critical, make
sure the target is at least twice as large as the spot size.
Distance & Spot Size
As the distance (D) from the object increases, the spot size (S) of the area
measured by the unit becomes larger. See Graphic on Page 4.
Locating a Hot Spot
To find a hot spot aim the thermometer outside the area of interest, then
scan across with an up and down motion until you locate hot spot.
Emissivity
Emissivity is a term used to describe the energy-emitting characteristics of
materials. Most (90% of typical applications) organic materials and painted
or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit).
Inaccurate readings will result from measuring shiny or polished metal
surfaces. To compensate, cover the surface to be measured with masking
tape or flat black paint. Allow time for the tape to reach the same
temperature as the material underneath it. Measure the temperature of the
tape or painted surface.
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
7
sales@GlobalTestSupply.com
Emissivity Values
Substance
Thermal
Emissivity
Substance
Thermal
Emissivity
0.98
Asphalt
0.90 to 0.98
Cloth (black)
Concrete
0.94
Human skin
0.98
Cement
0.96
Lather
0.75 to 0.80
Sand
0.90
Charcoal (powder)
0.96
Earth
0.92 to 0.96
Lacquer
0.80 to 0.95
Water
0.92 to 0.96
Lacquer (matt)
0.97
Ice
0.96 to 0.98
Rubber (black)
0.94
Snow
0.83
Plastic
0.85 to 0.95
Glass
0.90 to 0.95
Timber
0.90
Ceramic
0.90 to 0.94
Paper
0.70 to 0.94
Marble
0.94
Chromium oxides
0.81
Plaster
0.80 to 0.90
Copper oxides
0.78
Mortar
0.89 to 0.91
Iron oxides
0.78 to 0.82
Brick
0.93 to 0.96
Textiles
0.90
Battery Replacement
1. When battery power is not sufficient, LCD will display “
” and
replacement with one new 9V battery is required
2. Open battery cover, take out the battery from the instrument and replace
with a new 9V battery and place the battery cover back into place
Pantone 534 Blue
Pantone 123 Yellow
Blue - 100/80/30/5
Yellow - 0/27/100/0
Pantone 485 Red
Pantone 123 Yellow
Red - 10/100/100/5
Yellow - 0/27/100/0
Pantone 534 Blue
Blue - 100/80/30/5
For service on this or any other REED product or information on other
REED products, contact REED Instruments at info@reedinstruments.com
Black
Find Quality
Pantone 534Products
Blue - 100/80/30/5 Online at:
www
www.
reedinstruments
Rich Black 20/20/20/100
GlobalTestSupply.com
com
8
sales@GlobalTestSupply.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising