Features Product Snapshot
Powerware® 9125
Uninterruptible Power System
Product Focus
700-6000 VA
Features
• Protects mission-critical applications from downtime, data loss and corruption, and process
interruption by providing continuous, clean power
• Secures connected equipment from damage or degradation caused by power anomalies
• Increases battery life through ABM® technology, resulting in more uptime and fewer
battery replacements
Powerware 9125 6000 VA
• Offers load segments (on 700-3000 VA units) that enable orderly shutdown of non-essential equipment
during power outages to extend backup power time for critical systems
• Delivers deployment flexibility while conserving valuable rack space, by offering rackmount or tower
installation choices
• Ensures data and system integrity with a complete power management software suite
• Provides investment protection with a two-year limited warranty, 10-year pro-rated warranty, $250,000
load protection guarantee (US and Canada)
Product Snapshot
Power Rating: 700-6000 VA
Voltage: 120, 208 and 230 Vac
Frequency: 50/60 Hz
(auto-sensing)
Configuration:Rackmount
or tower
When your work depends on
constant availability, the potential dangers of utility power
simply cannot factor into the
equation. In your business, mission-critical means just that, and
downtime equals “dead time.”
Where can you turn for a power
quality solution that is just as
dedicated as you are? Enter the
Powerware 9125 UPS, designed
by Eaton to alter the face of
power management forever.
Combining superior power quality with a cache of innovative
features, the Powerware 9125
UPS delivers the ultimate in
protection, truly isolating your
equipment from all nine of
the common power anomalies
lurking in public utility power.
Available as either a rackmount
or stand-alone unit, the compact and elegant 9125 supplies
continuous, conditioned power
to all connected equipment,
delivering large-scale power
protection in a sleek package
small enough to fit beneath
your desk.
The ideal solution for banking
and security systems, manufacturing process control, heavily
configured servers, or any critical application, the Powerware
9125 makes power-related
downtime a thing of the past.
We invite you to read on, and
discover more of what has
made the Powerware 9125 UPS
an industry legend.
Double-conversion,
online design offers
superior reliability
and protection
The Powerware 9125 is a
double-conversion online UPS,
which means it is constantly
conditioning and controlling AC
output during normal operating
conditions.
Unlike other
Powerware 9125 3000 VA
commercially-available technologies, a double-conversion online
design assures that in the event of a utility power failure, there is
zero delay transferring to backup power.
The double-conversion architecture incorporates both
a rectifier and inverter to completely isolate the output power
from all input anomalies. Only a true online system such as the
Powerware 9125 protects connected equipment from all nine of
the most common power problems: outages, sags, surges, spikes,
brownouts, line noise, frequency variation, switching transients,
and harmonic distortion.
Even when presented with the most severe power problems, power
output remains stable, within three percent of nominal voltage.
The Powerware 9125 supports a wide range of input voltages, so
it is not consuming battery capacity during minor power fluctuations. Battery capacity is saved for times
when utility power is
completely lost. If an
outage occurs, the
Powerware 9125 transfers to battery with no
break in power, making it an ideal UPS for
equipment sensitive to
Data based on tests performed by an independent battery manufacturer.
voltage fluctuations.
Double battery life with ABM technology
Most UPS manufacturers in the market today offer batteries that are
constantly “trickle-charged” —a process that degrades the battery’s
internal chemical composition, reducing potential battery service
life by as much as 50 percent. In contrast, our exclusive ABM technology uses sophisticated sensing circuitry and an innovative threestage charging technique that doubles the useful service life of UPS
batteries while optimizing battery recharge time. The Powerware
9125 provides up to 60 days’ notice of the end of useful battery
service life, to allow ample time to hot-swap batteries without ever
having to shut down connected equipment.
Maximize battery backup time for critical systems
LanSafe® power management software enables independent control
of load segments, which are groups of receptacles on the rear panel
of the Powerware 9125 UPS (700-3000 VA). This feature allows
users to manage scheduled shutdowns and sequential startups of
protected loads. During a power
outage, users can shut down
power to non-critical devices,
thereby extending battery backup
time available for critical devices.
When the load segments feature is used with Powerware
ConnectUPS connectivity cards, users can remotely re-boot lockedup network equipment. Simply link to the ConnectUPS connectivity
card over the network, and toggle the password-protected load
segment controller to get your network back online.
Add battery modules for even more backup capacity
Up to four Extended Battery Modules (EBMs) can be added to provide additional battery backup capacity as necessary. These battery
modules are hot-swappable and can be replaced at any time without interrupting UPS operation and load protection.
Load Segment 1
Load Segment 2
Battery Runtimes (in minutes)
Load
Standard
Internal
Batteries
1 EBM 2 EBMs
3 EBMs
4 EBMs
700/1000 VA Models
200 VA/140W 37
271
546
-
-
400 VA/280W 19
142
278
-
-
700 VA/490W
9
72
156
-
-
850 VA/595W 6
59
124
-
-
1250 VA/875W 11
46
87
-
-
1000 VA/700W 5
48
104
-
-
1250-2000 VA Models
400 VA / 280W
46
177
331
501
682
700 VA/490W
25
96
180
272
370
850 VA/595W
21
76
142
214
292
1000 VA/700W 16
61
115
174
237
1250 VA/875W 11
46
87
131
179
1500 VA/1050W 8
37
70
106
144
1800 VA/1260W
6
30
57
85
116
2000 VA/1400W 5
26
49
74
100
2500/3000 VA Models
1250 VA/875W
16
57
90
150
200
2500 VA/1750W
7
28
48
68
88
1500 VA/1050W
13
55
72
120
160
3000 VA/2100W
5
25
38
54
70
5000/6000 VA Models
1000 VA / 700W
64
179
308
448
-
2000 VA / 1400W
38
108
186
271
362
3000 VA / 2100W
34
70
122
178
237
4000 VA / 2800W
19
49
86
125
168
5000 VA / 3500W
13
37
65
96
128
6000 VA / 4200W
10
30
52
76
102
This table provides typical information. Runtimes are approximate and vary with equipment, configuration,
battery age, temperature, etc.
Powerware 9125 6000 VA
with 2 EBMs
Design and connectivity options offer maximum flexibility
Up to 3000 VA of UPS power is packed into only two units (2U) of
rack space; only five units (5U) for the 5000 and 6000 VA models.
The standard chassis (available in beach gray or black) can be
deployed as a tower unit or in a rack. Pedestal kits are standard
with units up to 3000 VA. Optional rack kits are available for all
ConnectUPS Web/SNMP card
models. An optional seismic kit is also available for select units.
Connectivity options are available to suit nearly any communication
requirement. The standard unit is equipped with an RS-232 serial
communications port. You can customize your UPS by adding
X-Slot® interface options for other types of communications:
Multi-server card
Enables a direct connection to the
Ethernet network and the Internet.
Monitor and mange your UPS with
a standard Web browser.
Modbus card
Provides serial connections for
monitoring and graceful shutdown
of up to five computer systems running various operating systems.
Relay card
Enables real-time monitoring
of power conditions through building management systems (BMS).
Provides simple alarm
notification via isolated
contacts to signal a change
of state in UPS operation
(typical in IBM® eServer®
iSeries applications).
Unify the management of UPS functions and
connections
Service the UPS without interrupting power
to downstream systems
The Powerware 9125 comes complete with the Powerware
Software Suite CD, including SNMP-compatible LanSafe power
management software to provide control and visibility over multiple UPSs. From a central vantage point, you can perform all
requisite management processes for power protection, such as
establishing a prioritized shutdown of network devices and client/server applications, testing all networked UPSs from one node,
analyzing trends and network conditions, and staying informed of
power problems via email broadcasts to mobile phones or pagers.
Powerware 9125 UPS models from 700 VA to 6000 VA offer optional
PowerPass® power distribution modules (PDMs) with the following
capabilities:
The Software Suite CD includes multimedia demonstrations of the
various Powerware software packages that Eaton offers: LanSafe v.
5, PowerVision® software, and Foreseer® software. Additionally, a
30-day trial version of PowerVision is included on the CD for exploration.
•Maintenance bypass switch in the PowerPass module enables
users to upgrade or replace the UPS while continuously
providing power to critical equipment
•Step-down transformer (2500-6000 VA) enables the UPS to be connected to energy-saving 208V or 240V input voltage, while providing appropriate output voltage combinations of 120V and 208V
through 240V for connected equipment
•Extra receptacles match the unique requirements of your
protected equipment
Backed by a comprehensive warranty program, the Powerware
9125 delivers the most reliable, efficient, and full-featured protection
available for your organization’s critical electronics.
Optional PowerPass Distribution Modules (PPDMs)
Model1
Part Number
Input Voltage
(VAC)
Output Voltage
(VAC)
Input
Connection
700 - 2000 VA Models
PPDM 700-1500 VA
05146519-001
120
120
PPDM 2000 VA
05146520-001
120
6-ft, L5-15P Attached power cord
120
Output Receptacles
Dimensions (H x W x D)
(6) 5-15R, (1) L5-15R 3.5 x 11.0 x 4.5
for Laser Printer Unprotected
6-ft, L5-20P Attached power cord
2.5
3.5 x 11.0 x 4.5
2.5
(6) IEC 320-C13, (1) IEC 320-C13 3.5 x 11.0 x 4.5
for Laser Printer Unprotected
2.5
6-ft, L5-30P (6) 5-20R, (1) L5-30R
3.0 x 17.0 x 23.9
Attached power cord
20
PPDM1-HV-US-P1 103002739-6501
208-240 208-240 / 120 16A, IEC 320-C20 Input connector
(6) 5-20R, (1) L14-30R
3.0 x 17.0 x 23.9
Country-specific, Detachable power cord
50
PPDM1-HV-US-P2 103002730-6501
208-240
120
16A, IEC 320-C20 Input connector (6) 5-20R, (1) L5-30R
3.0 x 17.0 x 23.9
Country-specific, Detachable power cord
50
PPDM1-HV-US-P3 103002731-6501
208-240 120
16A, IEC 320-C20 Input connector (6) 5-20R
3.0 x 17.0 x 23.9
Country-specific, Detachable power cord
50
PPDM 700-2000 VA
05146519-092
230
230
IEC 320-C14 Input connector
2500/3000 VA Models
PPDM2-LV-US-P1 103002742-6501
120
120
PPDM1-HV-US-HW 103002732-6501
208-240 208-240/120
(6) 5-15R
Weight (lb)
30A Terminal block (3 terminals)
30A Terminal block 3.0 x 17.0 x 23.9
50
(4 terminals)
PPDM2-HV-US-P1
103002733-6501
208-240
208-240
16A, IEC 320-C20 Input connector (1) L6-30R
3.0 x 17.0 x 23.9
Country-specific, Detachable power cord
20
PPDM2-HV-EU-P2 103002740-6501
208-240
208-240
16A, IEC 320-C20 Input connector (2) 16A, IEC 320-C19
3.0 x 17.0 x 23.9
20
Country-specific, Detachable power cord
PPDM2-US-HW
103002734-6501
208-240
208-240
30A Terminal block (3 terminals)
30A Terminal block 3.0 x 17.0 x 23.9
(3 terminals)
20
PPDM2-LV-US-HW 103002735-6501
120
120
30A Terminal block (3 terminals)
30A Terminal block 3.0 x 17.0 x 23.9
(3 terminals)
20
5000/6000 VA Models
PPDM, L6-30 103003214-6501
208-240
208-240/120
L6-30P
(1) L6-30R, (8) 5-15R
5.25 x 17.37 x 24.75
106
106
PPDM, L6-20 103003214-6502
208-240
208-240/120
L6-30P
(1) L6-20R, (8) 5-15R
5.25 x 17.37 x 24.75
PPDM, L5-30
103003214-6503
208-240
208-240/120
L6-30P
(1) L5-30R, (8) 5-15R
5.25 x 17.37 x 24.75
106
PPDM, L14-30 103003214-6504
208-240
208-240/120
L6-30P
(1) 14-30R, (8) 5-15R
5.25 x 17.37 x 24.75
106
PPDM, HW 103003214-6505
208-240
208-240/120
Hard-wired
Hard-wired
5.25 x 17.37 x 24.75
106
PPDM, EURO HW
103003214-6506
208-240 208-240/120
Hard-wired
Hard-wired
5.25 x 17.37 x 24.75
106
PPDM, L6-30&L14-30 103003214-6507
208-240 220-240/120
L6-30P
(1) L6-30R, (1) L14-30R, 5.25 x 17.37 x 24.75 106
(4) 5-15R
PPDM, L6-30 (2)
103003214-6508
208-240 208-240/120
L6-30P
(2) L6-30R, (4) 5-20R
5.25 x 17.37 x 24.75
106
PPDM, L6-20 (2)
103003214-6509
208-240 208-240/120
L6-30P
(2) L6-30R, (4) 5-20R
5.25 x 17.37 x 24.75
106
1. 5000/6000 VA PPDM Black Chassis Option, change order number from -55XX to -65XX.
Optional Mounting Hardware
Connectivity Option Cards
Description
Part Number
Model
PW9215 700 - 3000 VA Mounting Rail Kit, 2-post 2U,
05146726-5591
Fits in rear panel slot
PW9215 700 - 3000 VA Mounting Rail Kit, 4-post 2U,
05141562-0091
X-Slot ConnectUPS-X 103002974-5501
Web/SNMP/xHub Card
103005156
X-Slot ConnectUPS-M Card
05146288-5501 Fits in rear panel slot
103003226
X-Slot Multi-Server Card
05146447-5502 Fits in rear panel slot
PW9125 - 3000 VA Mounting Rail Kit, 4-post PW9125 5000/6000 VA Mounting Rail Kit, Beach Grey
PW9125 5000/6000 VA Mounting Rail Kit, Black
103003226-001
PW9125 5000/6000 VA Pedestal Kit, Beach Grey
103005431
PW9125 5000/6000 VA Pedestal Kit, Black
103003227-001
PW9125 700 - 3000 VA Seismic Kit, 05146871-5501
Three Unit (For 3 UPSs or EBMs)
PW9125 700 - 3000 VA Seismic Kit,
Five Unit (For 5 UPSs or EBMs)
05146875-5501
PW9125 5000/6000 Seismic Kit 3-unit
(1-UPS, 2 PPDM or Battery) Beach Grey
103003229-5501
PW9125 5000/6000 Seismic Kit 3-unit
(1-UPS, 2 PPDM or Battery) Black
103003229-6501
Part Number
Dimensions (H x W x D)
X-Slot Relay Card 1018460
(AS/400 compatible)
Fits in rear panel slot
X-Slot USB Card
05146508-5501
Fits in rear panel slot
X-Slot Modbus Card
103002510-5501
Fits in rear panel slot
Expansion Chassis (equipped with Modbus card)
5147063
Notes: 1.LanSafe cable DB9f to DB9m P/N 60420064-002 is shipped with the UPS.
Model Selection Guide - Powerware 9125
Model Number1
Part Number2 Power Rating Input (VA/Watt) Connection
Output Receptacles
Dimensions HxWxD (in / mm)
Unit Wt. (lb/kg)6
120 Vac Models3
PW9125 700
05146012-6501
700 / 490
5-15P
(6) 5-15R
3.5 x 17.0 x 19.4 / 89 x 432 x 494 34/15
PW9125 1000
05146002-6501
1000 / 700
5-15P
(6) 5-15R
3.5 x 17.0 x 19.4 / 89 x 432 x 494 34/15
PW9125 1250
05146008-6501
1250 / 875
5-15P
(6) 5-15R
3.5 x 17.0 x 19.4 / 89 x 432 x 494 50/23
PW9125 1500
05146005-6501
1500 / 1050
5-15P
(6) 5-15R
3.5 x 17.0 x 19.4 / 89 x 432 x 494 50/23
PW9125 2000
05146001-6501
2000 / 1400
5-20P
(6) 5-15R
3.5 x 17.0 x 19.4 / 89 x 432 x 494 50/23
PW9125 2000 20R
05146001-6506
2000 / 1400
5-20P
(4) 5-15R, (2) 5-20R
PW9125 2500
103002716-6591
2500 / 1750
L5-30P
(2) 5-15R,(2) 5-20R, (1) L5-30R
3.5 x 17.0 x 23.9 / 89 x 432 x 607 81.5/37
PW9125 3000
103002717-6591
3000 / 2100
L5-30P
(2) 5-15R,(2) 5-20R, (1) L5-30R
3.5 x 17.0 x 23.9 / 89 x 432 x 607 81.5/37
230 Vac Models5
PW9125 700i
05146622-6501
700 / 490
IEC 320-C14
(6) IEC 320-C13
3.5 x 17.0 x 19.4 / 89 x 432 x 494
34/15
PW9125 1000i
05146011-6591
1000 / 700
IEC 320-C14
(6) IEC 320-C13
3.5 x 17.0 x 19.4 / 89 x 432 x 494
34/15
PW9125 1250i
05146009-6501
1250 / 875
IEC 320-C14
(6) IEC 320-C13
3.5 x 17.0 x 19.4 / 89 x 432 x 494
50/23
PW9125 1500i
05146006-6591
1500 / 1050
IEC 320-C14
(6) IEC 320-C13
3.5 x 17.0 x 19.4 / 89 x 432 x 494
50/23
PW9125 2000i
103006571-6591
2000 / 1400
IEC 320-C14
(6) IEC 320-C13
3.5 x 17.0 x 19.4 / 89 x 432 x 494
50/23
PW9125 2500G
103004340-6591 2500 / 1750 Detachable L6-20P
(4) IEC-320-C13
(1) IEC-320-C19
3.5 (2U) x 17.0 x 23.9
81.5
PW9125 3000G
103002728-6591 3000 / 2100 Detachable L6-20P
(4) IEC-320-C13
(1) IEC-320-C19
3.5 (2U) x 17.0 x 23.9
81.5
81.5
3.5 x 17.0 x 19.4 / 89 x 432 x 494 50/23
PW9125 2500G HW
103004341-6591
2500 / 1750 Hard-wired
Hard-wired
3.5 (2U) x 17.0 x 23.9
PW9125 3000G HW
103004342-6591
3000 / 2100 Hard-wired
Hard-wired
3.5 (2U) x 17.0 x 23.9
81.5
PW9125 5000g HW 103003623-6591
5000 / 3500
Hard-wired
Hard-wired
8.63 x 17.37 x 24.94 / 219 x 441 x 633 206/93.4
PW9125 5000g
103003633-6591
5000 / 3500
L6-30P
L6-30R
8.63 x 17.37 x 24.94 / 219 x 441 x 633 206/93.4
PW9125 6000g HW
103003625-6591
6000 / 4200
Hard-wired
Hard-wired
8.63 x 17.37 x 24.94 / 219 x 441 x 633 206/93.4
PW9125 6000g
103003635-6591
6000 / 4200
L6-30P
L6-30R
8.63 x 17.37 x 24.94 / 219 x 441 x 633 206/93.4
1. 50/60 automatic frequency selection. 2. Black chassis option, change order number from -5501 to -6501 (for 700 VA -2000 VA & 5000/6000 VA models only). 3. 120V models are 110V, 120V, 127V user-selectable. 4. 208V
Models are 208V, 220V, 230V, 240V user-selectable. 5. 230V models are 208V, 220V, 230V, 240V user-selectable. 6. add 8.5 lbs for shipping weight. Optional Extended Battery Modules (EBMs)
Model1
Part Number
Dimensions (H x W x D)
Weight (lb)
PW9125 24 EBM For 700/1000VA Models Only 05146502-6591
3.5 x 19.0 x 19.4
65
PW9125 48 EBM For 1250,1500,2000VA Models Only 05146074-6591
3.5 x 19.0 x 19.4
65
PW9125 72 EBM For 2500 & 3000 Models Only 103002836-6591
3.5 x 17.0 x 23.9
93
PW9125 240 EBM For 5000 & 6000 Models Only 103003387-6591
5.25 x 17.0 x 24.75
169
PW9125 48Vdc Extended Battery Cabinet
124100014-002
17.2 x 24.6 x 28.3
665
1. Black chassis option, change order number from -5501 to -6501 (for 700 VA -2000 VA & 5000 / 6000 VA models only).
Technical Specifications1
Electrical Input
700 – 3000 VA
5000/6000 VA
Nominal Voltage
120 Vac, 208 - 240 Vac
208 - 240 Vac
Voltage Range
120V: 80-144V (without using batteries)
160-288V (without using batteries)
208/230V: 160-288 (without using batteries)
Input Power Factor
>.95, typical
>.96 in any mode
Frequency
50 or 60 Hz, auto-sensing
Frequency Range
45-65 Hz
50 Hz: 47-53 Hz
60 Hz: 57-63 Hz Electrical Output
On Utility Voltage Regulation
± 3% of nominal
On Battery Voltage Regulation
± 3% of nominal
Efficiency
89-92%, depending on load
>85% Online Mode; >90% High-efficiency Mode
Frequency Regulation
± 3 Hz online; ± 1 Hz on battery
± 3 Hz online; ± 1 Hz on battery;
± 3 Hz High-Efficiency Mode
Load Crest Factor
3 to 1 Battery
Internal Battery Type
9 Ah, Sealed, lead-acid; maintenance free
7 Ah, Sealed, lead-acid; maintenance free
EBM Battery Type
9 Ah, Sealed, lead-acid; maintenance free
9 Ah, Sealed, lead-acid; maintenance free
Battery Runtime
See Battery Runtimes table
Battery Replacement
Hot-swappable internal and external batteries
Recharge Time
<2 hrs. From complete discharge to 80% capacity at nominal line conditions
Start-On-Battery
Allows start of UPS without utility input
General
Topology
Diagnostics
UPS Bypass
Dimensions and Weights
True online, double-conversion
Full system self-test on power up
Automatic on overload or UPS failure
See Model Selection Guide
Communications
Serial Port
RS-232 communications port standard; RS-232 and USB communications port standard;
optional X-Slot modules available
optional X-Slot modules available
Communications Cable
6-foot communications cable included
Environmental
Safety Markings
120 V: UL, CSA, and NOM; 230 V: UL, CSA, VDE,
UL, cUL, VDE, CE, NOM, NYCE, GS
CE S, D, N, FI, B, NOM, R; 208 V: UL, CSA
EMC Markings
FCC Class B and VCCI Class II 3000 FCC Class A
FCC-A, VCCI-A, BSMI-A, C-Tick, CE Compliance
Surge Suppression
IEEE/ANSI C62.41 Category B (formerly 587)
ANSI C62.41 Category B3, and
EN61000-4-5 Level 3 Criteria B
Audible Noise
<45 dBA (on utility); <50 dBA (on battery)
Ambient Operating/
0 to 40º C (32 to 104º F)
Heat Dissipation
2066 BTU/hr. Max
Leakage Current
< .6 mA Typical
Storage Temperature
0 to 25º C (32 to 77º F)
Relative Humidity
0 to 90%, non-condensing
5 to 90%, non-condensing
REPO Port
NEC Code 645-11 intent and UL requirements
Network Transient In and out jack for models only or 10 Base-T
N/A
Protector
network cable; protection. UL497A tested
1. Specifications are typical and subject to change without notice due to continuing product improvement programs.
UNITED STATES
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
www.powerware.com
Canada
Ontario: 416.798.0112
Toll Free: 1.800.461.9166
LATIN AMERICA
Argentina: 54.11.4343.6323
Brazil: 55.11.3616.8500
México: 52.55.5488.5252
Europe/Middle East/Africa
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.7841.666.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
Asia Pacific
Australia/NZ: 61.2.9693.9366
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6825.1668
Powerware, ABM, X-Slot, PowerVision,
Foreseer, LanSafe, and PowerPass are trade
names, trademarks and/or service marks of
Eaton Electrical Inc. or its subsidiaries and
affiliates. All other trademarks are property
of their respective owners.
© 2007 Eaton Corporation
All Rights Reserved
Printed in USA
9125FXA
February 2007
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising