DIN Rail TimeServer - hopf Elektronik GmbH

DIN Rail TimeServer - hopf Elektronik GmbH
Industriefunkuhren
______________________________
Technical Manual
6875LAN-7273
GPS DIN Rail TimeServer
for NTP / SINEC H1





with AC power supply with wide input range
two independent serial interfaces
DCF77 antenna simulation
IRIG-B output - analogue and digital
three programmable pulse outputs (optical coupler)
Optional: Output of pulses and serial data strings via fiber optic (ST)
ENGLISH
Version: 01.00 - 11.05.2012
2/9
6875LAN-7273 DIN Rail TimeServer - V01.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INPORTANT NOTES
Symbols and Characters
Operational Reliability
Disregard may cause damages to persons or material.
Functionality
Disregard may impact function of system/device.
Information
Notes and Information.
6875LAN-7273 DIN Rail TimeServer - V01.00
3/9
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SERVICE RELIABILITY
Safety regulations
The safety regulations and observance of the technical data serve to
ensure trouble-free operation of the device and protection of persons and
material. It is therefore of utmost importance to observe and compliance
with these regulations.
If these are not complied with, then no claims may be made under the
terms of the warranty. No liability will be assumed for any ensuing
damage.
Safety of the device
This device has been manufactured in accordance with the latest
technological standards and approved safety regulations
The device should only be put into operation by trained and qualified staff.
Care must be taken that all cable connections are laid and fixed in
position correctly. The device should only be operated with the voltage
supply indicated on the identification label.
The device should only be operated by qualified staff or employees who
have received specific instruction.
If a device must be opened for repair, this should only be carried out by
employees with appropriate qualifications or by hopf Elektronik GmbH.
Before a device is opened or a fuse is changed all power supplies must
be disconnected.
If there are reasons to believe that the operational safety can no longer be
guaranteed the device must be taken out of service and labelled
accordingly.
The safety may be impaired when the device does not operate properly or
if it is obviously damaged.
CE-Conformity
This device fulfils the requirements of the EU directive
2004/108/EC "Electromagnetic compatibility" and 2006/95/EC "Low
voltage equipment".
Therefore the device bears the CE identification marking
(CE = Communautés Européennes = European communities)
The CE indicates to the controlling bodies that the product complies with the requirements of
the EU directive - especially with regard to protection of health and safety for the operator
and the user - and may be released for sale within the common markets.
4/9
6875LAN-7273 DIN Rail TimeServer - V01.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
Contents
Page
1 General .......................................................................................................................... 7
2 Principle of Function .................................................................................................... 8
3 Requirements for Commissioning of 6875LAN-7273 ................................................. 9
4 Commissioning 6875LAN-7273 .................................................................................... 9
6875LAN-7273 DIN Rail TimeServer - V01.00
5/9
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
6/9
6875LAN-7273 DIN Rail TimeServer - V01.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GENERAL
1
General
The GPS DIN Rail TimeServer for NTP / SINEC H1 consists of the following components:
1. AC wide range power supply unit
2. GPS Module 6875 (optionally available with FO output)
3. NTP / SINEC H1 LAN board 7273 DIN Rail - Version for DIN Rail
There is an appropriate technical manual for each of those single components available
(Version 11.05.2012):
Ref. 1)
Ref. 2)
Ref. 3)
Technical Manual 1: Power Supply Unit
Description:
AC Power Supply AC-M05-D
File name:
e_4465AC_4475AC_4800AC_6870AC_6875AC_Netzteil_0102.pdf
Version:
01.02
Technical Manual 2: Module 6875
Description:
GPS radio controlled clock
File name:
e6875_0800.pdf
Version:
08.00
Technical Manual 3: Board 7273
Description:
NTP/SINEC H1 LAN Board - Model 7273 and 7273RC
File name:
e7273-7273RC_0100.pdf
Version:
01.00
6875LAN-7273 DIN Rail TimeServer - V01.00
7/9
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
PRINCIPLE OF FUNCTION
2
Principle of Function
The integrated power supply unit AC-M05-D supplies the GPS Module 6875 and the
NTP / SINEC H1 LAN board 7273 with the required operating voltage.
The necessary time information in form of serial data telegram and highly accurate PPS
signal will be transmitted from the GPS module 6875 to the NTP / SINEC H1 LAN board
7273.
Type of Housing 6 (L = 175.0 mm; W = 135.0 mm; Clip = 80.0 mm)
8/9
6875LAN-7273 DIN Rail TimeServer - V01.00
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
REQUIREMENTS FOR COMMISSIONING OF 6875LAN-7273
3
Requirements for Commissioning of 6875LAN-7273
Configuring the GPS Module 6875 for NTP / SINEC H1 LAN Board 7273 it is necessary to:

Activating the function by the hopf company

Hardware/Firmware: All devices FG6875xx with firmware version 05.00 and
higher

Remote Software: hmc version 01.06
hmc driver 'hopf6875_05xx_RS232_v01xx.drv'

Web Browser:
Internet Explorer, Mozilla Firefox, Opera, etc.
If the required hmc driver 'hopf6875_v05xx RS232v01xx.drv' is not
installed in the hmc, it can be installed separately
(hmc menu: Devices  Driver Management  Drivers Add … )
4
Commissioning 6875LAN-7273

Mounting of unit (see Technical Manual 1: Power Supply Unit)

Connect GPS antenna system with Module 6875
(see Technical Manual 2: Module 6875)

Connect unit to mains voltage
(see Technical Manual 1: Power Supply Unit)

Set basis parameters of Module 6875
(see Technical Manual 2: Module 6875)

Check synchronisation of Module 6875
(see Technical Manual 2: Module 6875)

6875LAN-7273 extended Configuration for NTP / SINEC H1 LAN Board 7273:
o Enter LAN parameter (IP address, gateway and net mask) for ETH0
interface of NTP / SINEC H1 LAN board 7273
Activating of DHCP mode of the NTP / SINEC H1 Board 7273 is done by
setting the IP address to >000.000.000.000< (no valid IP address).

Configuring the NTP / SINEC H1 LAN Board 7273 can be found in the
Technical Manual 3: Board 7273.
The DIP switch DS1 setting is fixed used for the NTP / SINEC H1
LAN Board 7273 (DS1.1 - DS1.7 = off; DS1.8 = on).

Set up NTP / SINEC H1 LAN Board 7273 as NTP server in the NTP Client/Server
PCs or systems
6875LAN-7273 DIN Rail TimeServer - V01.00
9/9
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising