PAD02 Z-Wave Smart Dimmer Socket

PAD02 Z-Wave Smart Dimmer Socket
controller to fully utilize the device. Its functionality and supported command classes
PAD02
is identical when included as a secure and non-secure device.
Z-Wave Smart Dimmer Socket
Adding to Z- WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
switch on and off, dim level, or carries out add, remove, reset or association.
When first power is applied, its LED flashes on and off alternately and repeatedly at
0.5 second intervals. It implies that it has not been assigned a node ID and start auto
inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not
have Node ID and just connect the dimmer to main power.
Built-in High Breaking Capacity current fuse protection.
Note: Auto inclusion timeout is 2 minute during which the node information of
Rating: 1.25A 250V.
explorer frame will be emitted once every several seconds. Unlike “inclusion” function
Built-in Thermal Cut-off Fuses protection.
as shown in the table below, the execution of auto inclusion is free from pressing the
Rated Temperature :125 °C; Rating: 2A 250V.
On/Off button on the dimmer.
PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides
The table below lists an operation summary of basic Z-Wave functions. Please refer
electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and
TM
to the instructions for your Z- Wave
support it in the lighting fixture. The use of socket allows lamps to be safely and
certificated primary controller to access the
setup function, and to Add/Remove/Associate devices
conveniently replaced. You can On/Off the light by pressing the button briefly,
Function
No node ID
or a long pressing to control the brightness of dimmable lightbulb.
This dimmer is a transceiver which is a security enabled device which based on ZWave Plus technology. Z-Wave Plus
Plus
TM
TM
Add
enabled devices displaying the Z-Wave
logo can also be used with it regardless of the manufacturer, and can also be
TM
used in other manufacturer’s Z- Wave
enabled networks. Remote dim level control
of the connected light is possible with other manufacturer’s wireless Controller.
Since PAD02 supports Security Command Class, it can learn with a Secured enabled
1
Description
The Z-Wave Controller does not allocate
a node ID to the Switch.
1. Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
2. Pressing Include button of PAD02
three times within 2 seconds will
enter inclusion mode.
Annotation
LED 2-second on, 2-second
off
1.
Remove
1.
Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
Pressing Include button of PAD02
three times within 2 seconds will
enter exclusion mode.
Node ID has been excluded.
Reset
1. Pressing Include button of PAD02
three times within 2 seconds will
enter inclusion mode.
2. Within 1 second, press Include button
of PAD02 again for 5 seconds.
3. IDs are excluded.
No node ID
Learning
0.5s On, 0.5s Off (Enter
auto inclusion)
Use this procedure only in
the event that the primary
controller is lost or otherwise
inoperable.
Choosing a Suitable Location
1. Do not locate the dimmer facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the dimmer is 0°C~40°C.
3. Do not locate the dimmer where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
0.5s On, 0.5s Off (Enter
auto inclusion)
4. After putting it into use, the body of dimmer will become a little bit hot of which
1.
The PAD02 is an always listening
Z-Wave device, so associations
may be added or removed by a
controller at any time.
Or If your controller requires to have
the PAD02 send a 'node information
frame' or NIF for associations, then
pressing the On/Off button three
times within 2 seconds will cause
the PAD02 to send its NIF.
2. There are only two groups for the
switch
Association
Under normal operation, when the dimmer has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing On/Off button, it will stop flashing temporarily.
When PAD02 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
phenomenon is normal.
Manual dim level control :
To manually switch on the light, press and release the On/Off button shortly when the
light is off. The light will dim from off to the level which was set before switch off. To
manually switch off the light, press and release the On/Off button shortly when the
light is on. To adjust the dim level, press and hold the On/Off button until the desired
dim level is achieved, then release.
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Programming :
1. Basic Command Class / Multilevel Switch Command Class
The dim level can be set by BASIC and MULTILEVEL SWITCH commands.
Controller.
1-1 BASIC_GET
LED Indication
Upon receipt of the following commands from a Z-Wave Controller, the dimmer
To distinguish what mode the switch is in, view from the LED for identification.
will report its dim level to the node inquired.
State Type
Normal
LED Indication
Whenever we switch On and off of the PAD02 by On/Off button or
RF command, the LED will lights up when switch on; whereas LED
off when switch off.
Basic Get Command: [Command Class Basic, Basic Get]
2
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0 ]
Report ON:[Command Class Basic, Basic Report, Value = 1~99 ]
one association group with one node support for Grouping 1. For group 1, the
dimmer
will report ALARM_REPORT 、DEVICE_RESET_LOCALLY_NOTIFICATION and
1-2 BASIC_SET
MULTILEVEL_SWITCH_REPORT.
Upon receipt of the following commands from a Z-Wave Controller, the dimmer
2-1-1 Overload alarm report
will be set to the dim level.
When PAD02 detects overload, it will send Alarm Report to group 1 node. After
Basic Set Command:[Command Class Basic, Basic Set, Value = 1~99 ]: the light
attached to the dimmer turns on.
detecting overload state and sending this alarm report, PAD02 will turn off the light
automatically and lockout the On/Off button. The only thing to do is unplug PAD02
Basic Set Command:[Command Class Basic, Basic Set, Value = 0 ]: the light
attached to the dimmer turns off.
and reduce the load. Then re-plug PAD02 and it will work again.
1-3 MULTILEVEL SWITCH GET
Upon receipt of the following commands from a Z-Wave Controller, the dimmer will
The content of Alarm Report
report its dim level to the node inquired.
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type =
0x08, Alarm Level = 0xFF]
Multilevel Switch Get Command: [Command Class Multilevel Switch, Multilevel
Switch Get]
Multilevel Switch Report Command:
Report OFF: [Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0 ]
Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
2-1-2 Device reset locally notification :
When PAD02 is reset manually, it will send a DEVICE_RESET_LOCALLY_
NOTIFICATION to the nodes of group 1.
= 1~99 ]
2-1-3 Multilevel switch report :
1-2 Multilevel Switch SET
Whenever the level of PAD02 is
changed , it will send a
MULTILEVEL_SWITCH_ REPORT to the nodes of group 1.
Upon receipt of the following commands from a Z-Wave Controller, the dimmer
will be set to the dim level.
Multilevel Switch Report Command:
Report OFF: [Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0 ]
Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
= 1~99 ]
Multilevel Switch Set Command: [Command Class Multilevel Switch, Multilevel
Switch Set, Value = 1~99, Duration = 0~255 ]: the light attached to the dimmer
turns on.
Multilevel Switch Set Command: [Command Class Multilevel Switch, Multilevel
Switch Set, Value = 0, Duration = 0~255 ]: the light attached to the dimmer turns
off.
2-2 Group 2 Control_key1 : (Maximum 5 nodes)
When the On/Off status changes or the dim level is achieved manually, it will send
2. Z-Wave’s Group
BASIC_SET command to group 2 nodes to make them unanimous .
2-1 Group1 Lifeline : (Maximum 5 nodes)
Basic Set Command:
Dimmer Off:[Command Class Basic, Basic Set, Value = 0 ]
The dimmer can be set to send reports to associated Z-Wave devices. It supports
3
Class, it can receives the updated firmware image sent by controller via the Z-
Dimmer On:[Command Class Basic, Basic Set, Value = 1~99 ]
wave RF media. It is a helpful and convenient way to improve some function if
3. Z-Wave’s Configuration
needed.
Configuration
Parameter
Function
Size
(Byte)
Value
1
Dimmer
Level Report
mode
LED
indication
mode
1
1
2
Unit
Default
Description
0-1
1
0 : Disable
1-3
1
5. Command Classes
1 : Enable
The Switch supports Command Classes including…
1 : Show dimmer state
* COMMAND_CLASS_ZWAVEPLUS_INFO
2 : Show night mode
* COMMAND_CLASS_VERSION_V2
3 : One flash mode
Restore
dimmer state
4
1
0-2
1
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
0 : Dimmer off
1 : Last dimmer state
* COMMAND_CLASS_SECURITY
2 : Dimmer on
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
3-1 Dimmer level report mode :
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_
* COMMAND_CLASS_POWERLEVEL
REPORT to the nodes of group1. The default setting is Enable the function.
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_MULTILEVEL_V2
3-2 LED indication mode :
* COMMAND_CLASS_CONFIGURATION
3-2-1 Show dimmer State:When dimmer is on, LED is on. When dimmer is off,
* COMMAND_CLASS_ALARM
LED is off. The default setting is Show dimmer State.
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
3-2-2 Show Night mode:When dimmer is on, LED is off. When dimmer is off,
* COMMAND_CLASS_SCENE_ACTIVATION
LED is on.
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
3-2-3 One flash mode : When dimmer on/off state changes, LED will light on one
second and then off.
3-3 Restore dimmer state :
Whenever the AC power return from lost, PAD02 will restore the switch state which
could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last
dimmer state.
Screw lampholder Type:
4. Firmware update over the air (OTA)
Since the socket type for each country in Europe varies, refer to the outline for each
PAD02 is based on 500 series SoC and supports Firmware Update Command
socket suited for each country as follows:
4
EU TYPE: PAD02-1
Note: Please make sure that the intensity of the screw lampholder of the electrical
device must be Maximum Load (Ampere) and have same head as the enclosed
screw lampholder before inserting to the socket.
Troubleshooting
Symptom
The dimmer does not
work and LED off
Cause of Failure
1.The dimmer is not
plugged into the electrical
outlet properly
2.The dimmer break down
The dimmer LED
Check if the load plugged
illuminating, but cannot into the dimmer has its
control the ON/OFF
own ON/OFF switch
dimmer of the load
attached
The dimmer LED
1. Not carry out
illuminating, but the
association
detector cannot control 2. Same frequency
the dimmer
interference
US TYPE: PAD02-2
Recommendation
1. Check power connections
2. Don’t open up the dimmer and send it for
repair.
Set the ON/OFF switch of the load attached
to ON
1. Carry out association
2. Wait for a while to re-try
Specification
Operating Voltage
Maximum Load (Ampere)
Maximum Load (Ampere)
Screw lampholder Type:
100V~240V / 50Hz~60Hz
1A (Resistive load); ( PAD02-1; PAD02-2)
0.1A (dimmable led bulbs) ; ( PAD02-1; PAD02-2)
EU type: E27 to E14; PAD02-1
US type: E26 to E12; PAD02-2
Range
Operating Temperature
Frequency Range
RF Maximum Power
Modulation Type
5
Minimum 40 m in door 100m outdoor line of sight
0°C ~ 40°C
868.40MHz & 869.85MHz/ EU (PAD02-1);
908.4MHz & 916.0MHz/ USA (PAD02-2);
+5dBm
FSK (Frequency Shift Key)
device, pursuant to Part 15 of the FCC Rules.
** Specifications are subject to change and improvement without notice.
These limits are designed to provide reasonable protection against harmful interference in a
FCC ID : RHHPAD02
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
Warning:
correct the interference by one of the following measures:
1.Plug out to disconnect from power supply; Do not plug in line.
• Reorient or relocate the receiving antenna.
2. Do not exceed the max rating.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
Disposal
connected.
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible harm to
the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Company of License Holder:Philio Technology Corporation
FCC Caution: Any changes or modifications not expressly approved by the party responsible
Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City
for compliance could void the user's authority to operate this equipment.
24257, Taiwan(R.O.C)
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
6
7