New Owner`s Manual RM20_C_R.cdr

New Owner`s Manual RM20_C_R.cdr
Owner’s Manual
™
19” Pro Series Rack Mount (RK) Faceplate
Isolate.
Protect.
Inspire!
17” Consumer Series (C) Faceplate
Available in Black (B) and Silver (S) Colours
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer
Model Number
Description
Input
Output
Output
Connector
10 outlets
RM 20 BAL RK
Balanced 20A
240/208V
120V
Medical-grade
20A
RM 20 BAL CB
RM 20 BAL CS
10 outlets
RM 20 RK
Single 20A
120V
120V
Medical-grade
20A
RM 20 CB
RM 20 CS
Important Safety Instructions
CAUTION! To reduce the risk of electric shock and fire, do not remove the cover of this device. There
are no user serviceable parts inside. Please refer all servicing to licensed service technicians.
CAUTION! The international symbol of a lightning bolt inside a triangle is intended to alert the user to
uninsulated “dangerous voltage” within the device’s enclosure. The international symbol of an
exclamation point inside a triangle is intended to alert the user to the presence of important
operating, maintenance and servicing information in the manual accompanying the device.
CAUTION! To prevent electrical shock, match wide blade of plug to wide slot, fully insert.
CAUTION! To reduce the risk of electrical shock, do not expose this equipment to rain or moisture.
1. Read Instructions—All safety and operating instructions
should be read before operating the device.
11. Damage Requiring Service—The device should be
serviced by licensed technicians when:
2. Retain Instructions—The safety and operating
instructions should be retained for future reference.
• The plug or power supply cord has been damaged.
3. Heed Warnings—All warnings on the device and in the
operating instructions should be adhered to.
4. Follow Instructions—All operating and safety instructions
should be followed.
5. Water & Moisture—The device should never be used in,
on or near water for risk of fatal shock.
6. Ventilation—The device should always be located in such
a way that it maintains proper ventilation. It should never
be placed in a built-in installation or anywhere that may
impede the flow of air through its ventilation slots.
7. Heat—Never locate the device near heat sources such as
radiators, floor registers, stoves or other heat-generating
devices.
8. Power Cord Protection—Power cables should be routed
so they are not likely to be stepped on or crushed by items
placed on them or against them. Special attention should
be paid to areas where the plug enters a socket or fused
strip and where the cord exits the device.
9. Periods Of Non-Use—The device should be unplugged
when not being used for extended periods.
• Objects have fallen or liquid has spilled inside the device.
• The device has been exposed to moisture.
• The device does not appear to be operating properly or
exhibits a marked change in performance.
• The device has been dropped or the enclosure becomes
damaged.
12. Service—The device should always be serviced by
licensed technicians. Only replacement parts specified by
the manufacturer should be used. The use of unauthorized
substitutions may result in fire, shock, or other hazards.
13. Do not position the equipment so that it is difficult to
operate the disconnecting device (power cord).
14. If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the
equipment may be impaired.
15. The power switch should be in the “off” position when
connecting or disconnecting equipment from a Torus Power
unit.
16. CAUTION Some units can be very heavy, please use
safe practices when lifting.
10. Dangerous Entry—Care should be taken that no foreign
objects or liquids fall or are spilled inside the device.
³18 kg (39.7 lb)
³32 kg (70.5 lb)
³55 kg (121.2 lb)
www.TorusPower.com
™
Owner’s Manual
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer
03/12
REV.03/01/2012
Description
Torus Power PIUs (Power Isolation Units) combines the best
PIUs use ZeroSurgeâ patented series-mode surge removal
surge
filters to absorb dangerous voltage surges and safely dissipate
suppression
with
unique
toroidal
transformer
technologies from PLITRON to provide the ultimate in AC
them
power conditioning and protection for sensitive audio and
varistors). Also, unlike MOV-based protection, voltage surges
video equipment applications.
are not shunted to ground.
Units are available in either single 120V input, or dual 120V
Isolation is combined with proven proprietary technologies
(balanced) input.
from PLITRON in the over-sized toroidal transformer. NBT
Balanced input power from two standard 120V phases
provides high input power and noise cancellation. Using
balanced input power provides the benefits of symmetrical
power without the requirement to use GFCI (ground-fault
circuit interruption) outlets. GFCIs are prone to nuisancetrips. The toroidal isolation transformer steps-down the 240V
input to 120V to power equipment. (Where 240V balanced
without
using
failure-prone
MOVs
(metal
oxide
works as a low pass filter using the controlled leakage
inductance and capacitances within the transformer to cancel
common mode and differential mode noise. LoNo technology
has been used for years by high-end audio companies who
demand silent transformers. Imin technology reduces inrush
currents. UST provides additional common mode filtering
using a highly efficient Faraday screen.
input is unavailable, units may be configured for 208V
Low-impedance output with balanced high-power primary
operation.)
input provides the most unconstrained, yet protected, energy
source available to your equipment.
Shipping Carton & Packing Material
Placement & Ventilation
Please keep the original shipping box and all packing material.
Torus Power PIUs are extremely efficient devices, however,
This will ensure the PIU is protected in future transport.
they are also very high-power devices, and must be
In the unlikely event you have a problem and must return it for
service you must use the original packing material.
Ship the PIU only in the original packing material, as the unit is
not insurable by carriers otherwise.
adequately cooled.
PIUs have ventilation slots on the base, side panels and the
cover. Maintain at least 2.5cm distance from each of these
surfaces to anything else. Should your installation conditions
be
constricted,
additional
forced
air-cooling
may
be
necessary.
Do not install the PIU directly above heat-generating
equipment.
Maintain at least 15cm behind the PIU for adequate wiring
space.
Warranty
Torus Power products are warranted to be free from
This warranty is considered void if the defect, malfunction or
manufacturing defects for five years from the original date of
failure of the product or any component part was caused by
sale. This includes parts, labour and return shipping to the
damage (not resulting from a defect or malfunction) or abuse
first registered owner and all subsequent registered owners.
while in the possession of the customer. Failure to fully comply
Warranty coverage is extended to applicable products
with Torus Power operating instructions, voids the warranty.
registered or having proof-of-purchase (sales invoice, etc.).
N the event of a defect or malfunction, Torus Power will
remedy the problem by repair or replacement, as we deem
necessary, to restore the product to full performance.
www.TorusPower.com
™
Owner’s Manual
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer
03/12
REV.03/01/2012
Front Panel Layout
Circuit Protection
The front panel power switch is also
a circuit breaker. As a circuit breaker,
it prevents excessive current from
ON/OFF Switch / Circuit Breaker
entering the PIU.
When the power is on, the Switch is
illuminated. When the breaker trips,
the
switch
returns
to
its
“off”
position.
Thermal Protection
Torus PIUs will shut-down if internal
19” Pro Series Rack Mount Faceplate
unit temperature reaches excessive
Balanced 20A Model Number RM 20 BAL RK
levels.
Single 20A Model Number RM 20 RK
Input Current Rating
Per CSA code, devices with line
cords and plugs must not consume
more than 80% of a branch
circuit’s rating.
While Torus Power Isolation Units
are designed to handle well beyond
these limits, they must be marked
with a maximum input current that
17” Consumer Series Faceplate
satisfies the requirements.
Balanced 20A Model Numbers RM 20 BAL CB and RM 20 BAL CS
Single 20A Model Numbers RM 20 CB and RM 20 CS
Electrical Specifications
Model Number
RM 20 BAL RK
RM 20 BAL CB
Input Voltage
Input
Nominal
Current
Input Current
Load Current Capability
Rating
Limiting
½ cycle
1 second
10 seconds
Selectable 240VAC
10A
100A
80A
30A
10A
(2 x 120VAC, balanced)
Circuit Breaker
or 208VAC.
Front Panel
400A
200A
100A
16A
(see note above)
Factory wired for 240VAC 60Hz
RM 20 BAL CS
Range +/- 10% voltage
57-63Hz
RM 20 RK
RM 20 CB
120VAC, 60Hz
20A
Range +/- 10% voltage
Circuit Breaker
57-63Hz
Front Panel
RM 20 CS
www.TorusPower.com
™
Owner’s Manual
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer
03/12
REV.03/01/2012
Rear Panel Layout
Wall Receptacles
Torus PIUs are high-power products.
20A Medical-Grade Outlet
The outlets they are plugged into
should be sufficient to provide the
current to operate them without
tripping circuit breakers within your
junction panel.
Product Label
Dedicated
recommended.
Power Inlet
Balanced 20A, Model Numbers RM 20 BAL RK,
RM 20 BAL CB and RM 20 BAL CS
products,
circuits
are
Balanced
input
240VAC,
require
dual
120V phases (2 pole, 3-wire). Wall
outlets for 240VAC are rated at 250V
Accessory
Ground Stud
Single 20A, Model Numbers RM 20 RK,
RM 20 CB and RM 20 CS
and
will
likely
require
special
installation. Dedicated outlets, or
Rubber
any household or facility wiring
Mounting Feet
should be installed by a licenced
(may be
removed if rack electrician to local codes.
mounting)
Pictured below are suggested
Line Cords
Standard 15A 240/208V
Used on: Model Numbers RM 20 BAL RK,
RM 20 BAL CB and RM 20 BAL CS
Equipment end: IEC C19
Plug: 6-15P, Straight Blade, 2 pole,
3-wire grounding, 15A 250V
Cord: 3 x 14AWG
Length: 2.5 m
receptacle types for installation.
Standard 20A 120V
NEMA 6-15R
for Balanced 20A unit
Used on: Model Numbers RM 20 RK,
RM 20 CB and RM 20 CS
Equipment end: IEC C19
Plug: 5-20P, Straight Blade, 2 pole,
3-wire grounding, 20A 125V
Cord: 3 x 12AWG
Length: 2.5 m
NEMA 5-20R
for Single 20A unit
Mechanical Specifications
Model Number
Input
Line Cord
Suggested
Output
Connector
(included)
Wall
Connector
Receptacle
(Rear Panel)
(Rear Panel)
RM 20 BAL RK
Weight
(w x d x h)
40.5kg
483 x 426 x 159
duplex 20A
39.5kg
432 x 402 x 162
43.2kg
483 x 426 x 159
42.2kg
432 x 402 x 162
IEC 20A
N6/15, 14AWG
NEMA 6-15R
Qty 5 (10 outlets)
Inlet
C19, 15A/250V
15A - 250V
Medical-grade
RM 20 BAL CB
Size mm
RM 20 BAL CS
RM 20 RK
IEC 20A
N5/20, 12AWG
NEMA 5-20R
Qty 5 (10 outlets)
Inlet
C19, 20A/125V
20A - 125V
Medical-grade
RM 20 CB
duplex 20A
RM 20 CS
Height includes rubber mounting feet.
www.TorusPower.com
™
Owner’s Manual
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer
03/12
REV.03/01/2012
Torus Power products are
marketed worldwide through
Plitron Manufacturing Inc.
www.TorusPower.com
For sales contact:
torussales@plitron.com
Phone: 416-667-9914
Toll free: 1-800-754-8766
Fax:
416-667-8928
Technical inquiries:
torustechnical@plitron.com
Phone: 416-667-9914
03/12
REV.03/01/2012
™
Torus Power
#8 601 Magnetic Drive
Toronto, ON M3J 3J2
Canada
416-667-9914
Specifications subject to change without notice.
© Torus Power 2012
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising