SOUND REINFORCEMENT SYSTEMS
The RL 906D is a compact two-way loudspeaker consequently optimised for usage as a near-field
monitor. Either in an outside broadcasting van, on top of the meter bridge or in the home studio
and even as an precious hi-fi monitor it is more than convincing.
The RL 906D is identical in construction to the RL 906, which comes with an additional AES3 digital
input. There is an input selector on the back, where the left channel, the right channel or the
mono sum could be selected. According to all our other products, there is also the possibility to
use an analogue input signal. To synchronize the digital audio signal, with the video signal, you
could delay it in 16 steps frame wise. The frame refresh rate could be programmed internal.
By Musikelectronic Geithain’s coaxial technology a directivity was realised, that is especially adjusted
to the requirements of near-field monitoring, meaning small base widths and short listening
distances. Homogeneity, neutral tone quality and directional definition are most widely compatible
to the greater speakers from the RL series. This allows seamless working without familiarisation
phases along the whole audio production, regardless if it is in an outside broadcasting van, the
cutting room or in the great studio. The RL 906D is barely greater than a controlling monitor, but
it houses the power capability of a full-valued studio monitor. The bass reproduction as well as the
maximum level meet the requirements of most challenges. In 5 channel applications, demanding
a higher level in the lowest frequency range, the RL 906D is perfectly combined with our models
from the Basis series whereby it moves closer to the greater models.
The loudspeaker is equipped with a 13 cm (5”) cone woofer and a coaxial arranged 25 mm (1”)
tweeter. Each is powered by a separate MOSFET-amplifier with active crossover and electronic
overload protection. The amplifier is situated in the back of the cabinet. The RL 906D provides
a balanced XLR-type input with an adjustable input level. To compensate their placement, the
speaker features three controllers to continuously adjust the high- and low-frequency response
and also the frequencies around 300 Hz. These
controllers are attached to the cabinet’s backside. A
two-coloured LED indicates the state of the amplifier
and warns of clipping.
A variety of special stands and racks is available as
accessories. According fixing elements have been
integrated into the loudspeaker cabinet.
RL 906D
SPECIFICATIONS
general
active 2-way coaxial loudspeaker for listening distances
between 1 m and 2.6 m (3.3 ft and 8.6 ft)
maximum SPL
from 100 Hz ... 3 kHz
104 ... 108 dB / r = 1 m (3.3 ft)
bandwidth
50 Hz ... 20 kHz ± 3 dB
calibration:
acoustic output level / PE = - 14 dBu
76 dB / r = 1 m (3.3 ft)
directivity Index
from 200 Hz ... 10 kHz
increasing from 1.5 to 11 dB
inherent noise sound level
≤ 7 dB (A) / r = 1 m (3.3 ft)
total harmonic distortion
measured at 83 dB / r = 1 m (3.3 ft)
from 150 Hz ... 10 kHz
≤ - 40 dB
nominal input level
+ 6 dBu adjustable
Input impedance
≥ 10 kOhm RC balanced
electronic crossover frequencies
3 kHz
nominal output power amplifier
LF
HF
80 W / 4 Ohm
80 W / 4 Ohm
input connector
XLR 3F for AES3 and analogue
input choise switch for input connector analogue signal
AES3 left
AES3 right
AES3 left + right
rotary switch for delay
16 positions for up to 16 frames delay
frame rate
standard setting
programmable frequencies
50 Hz / 1 switch position equivalent 20 ms
24 Hz; 25 Hz; 29.97 Hz; 30 Hz; 50 Hz; 59.94 Hz; 60 Hz
supported sampling rates
44.1 kHz; 48 kHz; 88.2 kHz; 96 kHz; 176.4 kHz; 192 kHz
resolution
24 bit
loudspeaker systems
woofer
tweeter
130 mm (5”) cone
25 mm (1”) dome
operation and clipping indicator
LED on front side
power requirements
230 V ~ ± 10 %, 50 ... 60 Hz
115 V ~ ± 10 %, 50 ... 60 Hz (optional)
100 V ~ ± 10 %, 50 ... 60 Hz (optional)
power consumption
max. 100 VA at full load
mains connection
IEC power connector
temperature requirements
for use
for storage
humidity
+ 15°C ... + 35°C
- 25°C ... + 45°C
45 % ... 75 %
dimensions (h x w x d)
255 x 180 x 200 mm (10 x 7.1 x 7.9 inch)
weight
5.5 kg (12.1 lbs)
design of the cabinet
MDF wood in ash black veneered;
optional other veneers or colours
with holding device; optional without holding device
ACOUSTIC DIAGRAMS
90
[dB]
85
80
75
70
65
50
100
200
500
1k
2k
5k
10k
20k
[Hz]
FREE FIELD FREQUENCY RESPONSE
0°
45°h
1
[%]
0.5
0
100
200
500
1k
2k
TOTAL HARMONIC DISTORTIONS PA = 83 dB
musikelectronic geithain gmbh
STUDIO MONITORING - HIGHEND LOUDSPEAKER - SOUND REINFORCEMENT
SYSTEMS
SYSTEMS
Nikolaistraße 7
04643 Geithain / Germany
Tel: +49 (0) 34341 3110
Fax: +49 (0) 34341 31144
E-Mail: info@me-geithain.de
www.me-geithain.de
5k
K2
[Hz]
10k
K3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising