410 / 810 / 610 Quick Start V0.9- p1

410 / 810 / 610 Quick Start V0.9- p1
1. DVR
2. Quick Start Guide
3. IR Remote Control
4. Battery 2 pcs
*:Please press「DVR1」button
before operation it
5. CD
6. Hard Disk Mount 2sets
8. Power Adapter
11.IDE to SATA Power
Cord (for 16CH Only)
9. Power Cord
7. Screw 20pcs
10.SATA Cord 3pcs for 16CH,
2pcs for 8CH/4CH
12. DB 26 (for 16CH Only)
Note: Standard shipping products include neither HDD nor DVD R/W
410 / 810 / 610 Quick Start V0.9- p1
Step 1: Fix the HDD to rack mount with the screws as indicated.
Step 2: Place the HDD on the HDD plate and screw as indicated.
Step 3: Connect the power and the flat cables as indicated.
NOTE: The initialization of new-installed HDD is required before
recording, please refer to manual “4-9 UTILITY SETUP” for detail.
410 / 810 / 610 Quick Start V0.9- p2
Step 1:
Remove the front cover from DVR.
Step 2:
Put the CD-RW into the unit as
indicated.
Step 3:
Put DVR bottom up, screw to fix the
CD-RW as indicated.
Step 4:
Connect the power and the flat
cables as indicated.
410 / 810 / 610 Quick Start V0.9- p3
13
○
○
15
14
○
12
○
11
○
10
○
9
○
1
○
2
○
8
○
7
○
3
○
6
○
4
○
5
○
1 REC
○
Begin and stop recording.
2 PLAY
○
Play back in normal speed.
3 T-SRH
○
Display the search menu.
4 BACKUP/ESC
○
In LIVE mode, press to copy recorded data from HDD to USB device or
built-in CD-RW. In SETUP mode, press to return to last page.
5 MENU/
○
Display menu. In PLAYBACK mode, press to pause playback.
⑥ AUTO
Start auto sequencing of the channels in full screen mode.
7 ZOOM
○
Digital 2x zoom-in.
8 PIP
○
Display a picture in picture.
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
In SETUP mode, press to enter values.
9 ENTER/MODE
○
E
A
A
10
○
In PLAYBACK mode, press to switch between full screen, quad display,
9-channel display, and 16-channel display.
/
In SETUP mode, press to move cursor down. In PLAYBACK mode,
press to stop playing back.
/ SLOW
In SETUP mode, press to move cursor up. In PLAYBACK mode, press
to slow down.
12
○
/
In SETUP mode, press to increase value. In PLAYBACK mode, press to
play forwards.
13
○
/
In SETUP mode, press to reduce value. In PLAYBACK mode, press to
play backwards.
E
A
A
11
○
E
A
E
A
A
E
A
A
A
(Start from the left to the right.)
Power:Status of power
HDD:Hard Disk
14 LED Display
○
E
A
A
LAN:Network connected (Red) Remote user login.
REC:Recording (or Schedule Recording and recording are on)
PLAY:PLAYBACK
15 IR Sensor
○
A
E
A
Input sensor for the remote control.
USB 2.0 Port
Port for a USB memory stick, or USB external devices.
CD/DVD Writer
CD-RW or DVD±RW (Optional)
410 / 810 / 610 Quick Start V0.9- p4
(16CH)
③
2
1○
○
⑩
⑬
4
○
11
12 ○
○
9
○
5
○
6
○
8
7
○
○
1 MAIN monitor
○
BNC port for the main monitor
2 SPOT monitor
○
BNC port to display full screen image of all installed cameras in
sequence
3 VIDEO IN
○
BNC input ports for cameras, 16 in total
4 AUDIO IN
○
RCA input port for audio signal
5 VGA
○
VGA port
6 Fan
○
DC 12V 40mm X 40mm fan
7 DC 12V
○
Socket for a DC 12V input
8 POWER
○
Power switch
9 EXTERNAL I/O
○
EXTERNAL I/O port for DB 26 flat cable
⑩ NTSC/PAL Switch
Switch between NTSC and PAL format
11 LAN
○
Network port
12 E-SATA
○
External SATA hard disks port for expanding recording space
13 AUDIO OUT
○
RCA output for audio signal
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
410 / 810 / 610 Quick Start V0.9- p5
(8CH)
1
○
③
4
○
6
○
5
○
11
○
2
○
⑩
7
○
8
○
7
○
8
○
9
○
12
○
(4CH)
1
○
③
4
○
6
○
5
○
11
○
2
○
⑩
9
○
12
○
1 MAIN monitor
○
BNC port for the main monitor.
2 SPOT monitor
○
BNC port to display full screen image of all installed cameras in
sequence.
③ VIDEO IN
BNC input ports for cameras,
4 AUDIO IN
○
RCA input port for audio signal.
5 AUDIO OUT
○
RCA output for audio signal.
6 VGA
○
VGA port.
7 E-SATA
○
External SATA hard disks port for expanding recording space
8 Fan
○
DC 12V 40mm X 40mm fan.
9 EXTERNAL I/O
○
EXTERNAL I/O port (see below further definitions).
⑩ LAN
Network port.
11 NTSC/PAL Switch
○
Switch between NTSC and PAL format.
12 DC 12V
○
Socket for a DC 12V input.
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
E
A
A
(8CH)
(4CH)
410 / 810 / 610 Quick Start V0.9- p6
Under LIVE mode, you can watch all channel displays, receive live audio, and operate display
changes.
0B
Table 6-1 Description of the remote control functions under LIVE mode.
Button
Description
REC
Start/Stop recording.
PLAY
Start playing back the most recently recorded segment.
LOCK
Enable/Disable the Keypad function on the front panel, the remote
control and the mouse.
1,2,3,4
Select the channel to monitor in full screen from channel 1 to 4.
FREEZE
Turn on/off screen freeze function.
Switch to quad display.
Switch to 9-channel display. 4ch DVR doesn’t feature this function.
Switch to 13-channel display. 4ch and 8ch DVRs don’t feature this
function.
Switch to 16-channel display. 4ch and 8ch DVRs don’t feature this
function.
ENTER/MODE
Switch to full screen, quad display.
MENU/
Enable/ Disable setup Menu.
BK-UP/ESC
Enable/ Disable backup menu.
SRH
Enable/ Disable search menu.
MUTE
Switch channel 1 output audio / turn off LIVE audio
STATUS
Enable/ Disable Status.
OSD
Turn on/off the screen display
ZOOM/ZOOM-
Enable/ Disable double screen size display. You can click on the
channel name for choosing a specific channel.
PIP/ ZOOM+
Turn on picture-in-picture format. Click on the channel name can
switch to other channels.
PTZ
Enable PTZ control.
AUTO
In AUTO mode, all available channels will be cycled through in full
screen.
DVR1,2,3,4
Switch DVR ID1~4 *
Note:4CH will show quad display; 8 CH will show quad display and 9-channel display.
* Default ID is ID1. If remote control malfunctions, please press, “DVR1” button to renew
corresponding DVR ID.
410 / 810 / 610 Quick Start V0.9- p7
Table 6-2 Graphical icons displaying after right-clicking your mouse under LIVE mode.
Icon
Description
Resting the cursor on this icon will bring up the following
four menu icons.
Main MENU
SEARCH menu
BACK-UP menu
PTZ mode
Turn on/off recording. *Note 1
Playback.
Resting the cursor on this icon will bring up the following
five display icons.
FREEZE
PIP, picture in picture
ZOOM
AUTO sequence
LOCK
Full screen display
Quad display
9-channel display
13-channel display
16-channel display
Note:4CH will show quad display; 8 CH will show quad display and 9-channel display.
Note 1: Enable/Disable record function details and setup please refer to Appendix III: Record
Mode Comparison
410 / 810 / 610 Quick Start V0.9- p8
Table 6-3 Description of on screen graphical icons in LIVE mode
Icon
Description
Recording is on
LIVE Audio is on
1~4
LIVE Audio is off
Motion detected on the channel
Sensor triggered on the channel
Video loss detected on the channel
USB device detected
CD-RW or DVD writer detected
Remote user currently logging into DVR.
Timer recording is on.
Red:Timer is set and recording has been started.
White:Timer is set but recording has not yet been started.
AUTO-seq is on.
2X
2X zoom-in is on.
Freeze is on, screen is frozen.
LOCK is on.
PTZ control is on.
1~8
Remote control is set to 1-8, meanwhile, ID of each remote
control needs to match up with DVR to be able to control it. (DVR
default set up ID is 1.)
410 / 810 / 610 Quick Start V0.9- p9
Under LIVE mode, press PLAY to playback (default setup is quad display). The function icons will
appear in the right down corner on the screen, which can be dragged by mouse to other location on
the screen.
Table 7-1 Remote control functions under the PLAYBACK mode
Icon
ENTER/ MODE
MENU /
PLAY
/ SLOW
/
/
/
Description
Switch to full screen, quad, 9-channel or 16-channel display.
Turn on/off PAUSE.
Play back at normal speed.
Play back at slower speed. The speed will be slowed to 1/2, 1/4, 1/8,
1/16 by each pressing of the button till the slowest limitation of 1/16 of
the normal speed. Current playback speed is shown in the upper right
corner.
Fast rewind. Each press increases the speed to the next level. There are
six speeds: 2x, 4X, 8X, 16x, 32X and 64X.
Fast forward. Each press increases the speed to the next level. There
are six speeds: 2x, 4X, 8X, 16x, 32X and 64X.
Stop playback.
Table 7-2 The mouse operation under the PLAYBACK mode.
Icon
/
Description
「
/
」 Fast rewind
「
/
」Fast forward
Play/pause
「▲
/ SLOW」
,slow playback
「▼ / ■」stop
Playback channel by channel with snap shot display
Full screen display
(ch1 as default setup. If ch2 is wished to be viewed, please click on this
icon again. For the rest of the channels, please proceed with the same
instruction)
Quad display
(ch1-4 as default setup, if ch5-8 are wished to be viewed, please click on
this icon again. For the rest of the channels, please proceed with the
same instruction.)
9-channel display
(ch1-8 as default setup, if ch9-16 are wished to be viewed, please click
on this icon again. For the rest of the channels, please proceed with the
same instruction.)
16-channel display
Note:4CH will show quad display; 8 CH will show quad display and 9-channel display
P.S. If playback of a single channel is wished to be viewed, please double click on left key of
the mouse on the channel video image.
410 / 810 / 610 Quick Start V0.9- p10
Under LIVE mode, press PTZ to enter PTZ camera mode. The function icons will appear right down
corner on the screen, which can be dragged by mouse to other location on the screen.
Table 8-1 Remote Control functions under the PTZ mode
Button
Description
/ SLOW
Move PTZ up
/
Move PTZ down
/
Move PTZ to the left
/
Move PTZ to the right
ZOOM +
PTZ zoom-in
ZOOM -
PTZ zoom-out
FOCUS +
PTZ focus-in
FOCUS -
PTZ focus-out
IRIS +
PTZ iris-open
IRIS -
PTZ iris-close
TOUR
Make PTZ monitor pre-set locations in order*
PRESET+
Setup the Preset location
Number
Press “PRESET” key first then two-digit
number; DVR will set the current PTZ location at enter
ed preset number.
PLAY+
Go to Preset location
Number
Press “PLAY” key first then two-digit number, PTZ will go to
the correspondent preset number location.
PIP
Setup the beginning location for the Auto Patrol. *
FREEZE
Auto patrol (in line scan) *
ZOOM
Set up the ending location for the Auto Patrol. *
*PTZ communication protocols from different brands aren’t compatible 100% sometimes. The
refore, some of these functions may be unavailable.
410 / 810 / 610 Quick Start V0.9- p11
Table 8-2 The mouse operation under the PTZ mode.
Icon
Description
Leave PTZ Mode, back to the LIVE mode.
Pre-set number N.(1~64)
Go to pre-set number N.
Set PTZ at N.
「TOUR」pre-set locations in order. *
Set current location as the beginning for patrol line scan. *
「AUTO」auto patrol line scan. *
Set current location as the end of patrol line scan. *
To move PTZ in 8 directions.
PTZ zoom in; PTZ zoom out.
PTZ focus in; PTZ focus out.
PTZ IRIS open, PTZ IRIS close.
*PTZ communication protocols from different brands aren’t compatible 100% sometimes. The
refore, some of these functions may be unavailable.
410 / 810 / 610 Quick Start V0.9- p12
APPENDIX I
I-DVR.NRT REGISTRATION
DDNS Registration on I-DVR.NET
In the package of each DVR, you will find a sticker shows account information including username
and password that allows users to login I-DVR.NET for registration.
To register DDNS on I-DVR.NET, please follow the steps as shown.
Step 1. Please open IE browser and then enter “ http://i-DVR.NET/logon.asp ” in IE browser bar.
Next, “Control Panel Logo” dialog will appear. Enter the username and password provided
by the sticker and then press, “Logon.”
Step 2. After login successfully, enter name at “host” in “Add New Record” dialog. For example,
“icatchddns” is the host name, and then the address will be “icatchddns.idvr.net.” Select
“Standard” type and enter an IP address of the DVR. Input known IP address if any, or press
the “Add New” button if none.
Please enter any name by your choice at
Column, “host.” For example, “icatchddns”
Therefore, IE address will be
“icatchddns.idvr.net”
System will automatically show the current c
omputer IP. If the DVR IP is known, you can
type it in the column. If not, you can press
“Add new” button.
Step 3. The “Host Manager” dialog will show “Your new host record was created” when user setup
successfully. The “host.domain” column will show up the setup just entered.
If DDNS set up at DVR side successfully, the website will update the IP information in one
minute. The IP column will be renewed to the corresponding IP address by pressing “F5:
refresh” button.
“host.domain” is named by your choice.
“icatchddns.idvr.net” is what the main
server generates
If DVR IP has any changes, there are updates
Here at the same time. Press, “F5: Refresh”
And then IP column will update automatically to it’s real
IP Address.
410 / 810 / 610 Quick Start V0.9- p13
Step 4. Enter DVR →Main Menu → Network Setup → DDNS. Activate DDNS functions and
input related information.
410 / 810 / 610 Quick Start V0.9- p14
APPENDIX II DB 26 Definition (For 16CH DVR only)
1 3 5 7 9 11 13 15 17 19 21 23 25
First pin
2 4 6 8 10 12 14 16 18 20 22 24 26
Read Line
NUM.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11
12.
13.
WIRE
GND
GND
RS 485_B
RLY1_NO
RS485_A
RLY1_COM
VCC +5V
RLY1_NC
IR_LED
GND
SENSOR 1
SENSOR 2
SENSOR 3
COLOR
BLUE
GREEN
YELLOW
ORANGE
RED
BROWN
BLACK
WHITE
GRAY
AMETHYST
BLUE
GREEN
YELLOW
NUM.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
WIRE
SENSOR 4
SENSOR 5
SENSOR 6
SENSOR 7
SENSOR 8
SENSOR 9
SENSOR 10
SENSOR 11
SENSOR 12
SENSOR 13
SENSOR 14
SENSOR 15
SENSOR 16
COLOR
ORANGE
RED
BROWN
BLACK
WHITE
GRAY
AMETHYST
BLUE
GREEN
YELLOW
ORANGE
RED
BROWN
Note: Pin Num.7,9,10 allows extending IR receiver wire
(7IR Red,9IR White,10IR GND).
Brief connection method instruction:
If it’s connected externally to RS485 device (such as dome camera), please connect 485+ (p
ositive charge) to the 5th cable and connect 485- to the 3rd cable.
If it’s connected externally to sensor device (such as infrared sensor), please connect the po
sitive charge of equipment to the sensor (1~16) needed to be triggered and connect the neg
ative charge to any of GND cable (1, 2, 10.)
410 / 810 / 610 Quick Start V0.9- p15
APPENDIX III Record Mode Comparison
Comparison between different setups while in Default Record mode and after it’s been switch
ed.
Schedule Record-Motion
Schedule Record-Sensor
Default Record
Mode
After Switch Record
Mode
Enable
Enable
Default Record
Activated
Record and EventR
ecord have both
been activated
Disable
Default Record
Activated
Stop Record
Enable
Disable
Enable
Default Record
Activated
Record when event
occurs, and stop
when none.
Disable
Disable
Default Record
Activated
.
Stop Record
410 / 810 / 610 Quick Start V0.9- p16
APPENDIX IV Remote Monitoring IE ActiveX Control
Installation Instruction
When using IE for remote monitoring for the first time, IE ActiveX Control is needed to be
downloaded.
1. When remote monitoring on IE for the first time, an alert message occurs “Install ActiveX control”
on the tool bar.
2. Click at this alert message and select “Install ActiveX Control”
3. “Do you want to install this software” alert pops up. Select “Install”
410 / 810 / 610 Quick Start V0.9- p17
4. After installation, IE remote monitoring image appears.
5. If message, “Your security Settings do not allow web sites to use ActiveX controls installed on
your computer.” pops on when logging in, please follow the next instruction.
6. First select “Tools” on the tool bar and then select “Internet Options”
410 / 810 / 610 Quick Start V0.9- p18
7. Select Security →Trusted Sites → Sites
8. Enter DVR address (This address is only for demonstration. Please use the address depends on
the setup of on-site DVR.) into the blanks shown in picture, and then press “add.”
410 / 810 / 610 Quick Start V0.9- p19
9. Newly added website will appear at the trusted web sites list. Press close.
10. Go back to IE window, press refresh button or F5.
410 / 810 / 610 Quick Start V0.9- p20
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising