Features 18 Series - PIR movement detector 10 A

Features 18 Series - PIR movement detector 10 A
18 Series - PIR movement detector 10 A
Features
18.11
18.01
PIR movement detector for internal or external
installations - wall mounting
Small size
Adjustable ambient light intervention threshold
• Adjustable Light On Time
• Universal mounting position - permits the
selection of any area for survey
• Wide angle of survey
•
•
• 1 NO (SPST-NO) 10 A
• Internal installations
• Particularly suited for wall
mounting
18.01
• 1 NO (SPST-NO) 10 A
• External installations
• Particularly suited for wall
mounting
18.11
18.01
18.11
Contact specification
1 NO (SPST-NO)
Number of contacts
Rated current/Maximum peak current
A
10/20 (100 A - 5 ms)
Rated voltage/Maximum switching voltage V AC
Rated load AC1
VA
1 NO (SPST-NO)
10/20 (100 A - 5 ms)
230/230
230/230
2,300
2,300
(120/230 V) VA
250
450
250
450
Nominal lamp rating:incandescent (120/230 V) W
500
1,000
500
1,000
Rated load AC15
compensated fluorescent (120/230 V) W
200
350
200
350
uncompensated fluorescent (120/230 V) W
250
500
250
500
halogen (120/230 V) W
500
1,000
500
1,000
Standard contact material
AgSnO2
AgSnO2
120...230
120...230
—
—
2.5 VA (50 Hz)/—
2.5 VA (50 Hz)/—
96...253
96...253
—
—
100 · 103
100 · 103
5…350
5…350
10 s...12 min
10 s...12 min
110°
110°
10
10
Coil specification
Nominal voltage
V AC (50/60 Hz)
DC
Rated power AC/DC
Operating range
V AC (50/60 Hz)
DC
Technical data
Electrical life at rated load AC1
Ambient light intervention threshold
cycles
lx
Light on time after last detection
Angle of survey
Depth of field
Ambient temperature range
Protection category
m
°C
–10…+50
IP 40
–30…+50
IP 54
Approvals (according to type)
1
18 Series - PIR movement detector 10 A
Features
18.31
18.21
PIR movement detector for internal installations
Ceiling mounting
Small size
• Adjustable ambient light intervention threshold
• Adjustable Light On Time
• Wide angle of survey
•
•
• 1 NO (SPST-NO) 10 A
• Internal ceiling installation
• Surface mounting
• Output connected to supply
• 1 NO (SPST-NO) 10 A
• Internal ceiling installation
• Recessed mounting
• Output connected to supply
voltage
voltage
18.21
18.31
Contact specification
1 NO (SPST-NO)
Number of contacts
Rated current/Maximum peak current
A
10/20 (100 A - 5 ms)
Rated voltage/Maximum switching voltage V AC
Rated load AC1
VA
1 NO (SPST-NO)
10/20 (100 A - 5 ms)
230/230
230/230
2,300
2,300
(120/230 V) VA
250
450
250
450
Nominal lamp rating:incandescent (120/230 V) W
500
1,000
500
1,000
Rated load AC15
compensated fluorescent (120/230 V) W
200
350
200
350
uncompensated fluorescent (120/230 V) W
250
500
250
500
halogen (120/230 V) W
500
1,000
500
1,000
AgSnO2
AgSnO2
120...230
120...230
—
—
2 VA (50 Hz)/1
2 VA (50 Hz)/1
96...253
96...253
—
—
100 · 103
100 · 103
5…350
5…350
10 s...12 min
10 s...12 min
110°
110°
m
8
8
°C
–10…+50
–10…+50
IP 40
IP 40
Standard contact material
Coil specification
Nominal voltage
V AC (50/60 Hz)
DC
Rated power AC/DC
Operating range
V AC (50/60 Hz)
DC
Technical data
Electrical life at rated load AC1
Ambient light intervention threshold
cycles
lx
Light on time after last detection
Angle of survey
Sensing area diameter
Ambient temperature range
Protection category
Approvals (according to type)
2
18 Series - PIR movement detector 10 A
Features
18.21-0300
18.31-0300
PIR movement detector for internal installations,
with potential free contact
Applications where interface to PLC or BMS is
required
• Ceiling mounting
• Small size
• Adjustable ambient light intervention threshold
• Adjustable Light On Time
• Wide angle of survey
•
• 1 NO (SPST-NO) 10 A
• Internal ceiling installation
• Surface mounting
• Output with potential free
• 1 NO (SPST-NO) 10 A
• Internal ceiling installation
• Recessed mounting
• Output with potential free
contact
contact
18.21-0300
18.31-0300
Contact specification
1 NO (SPST-NO)
Number of contacts
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1
VA
10/20 (100 A - 5 ms)
1 NO (SPST-NO)
10/20 (100 A - 5 ms)
250/400
250/400
2,500
2,500
450
450
1,000
1,000
compensated fluorescent (230 V) W
350
350
uncompensated fluorescent (230 V) W
500
500
1,000
1,000
AgSnO2
AgSnO2
120...230
120...230
24
24 V
2 VA (50 Hz)/1
2 VA (50 Hz)/1
96...253
96...253
19.2...26.4
19.2...26.4
100 · 103
100 · 103
5…350
5…350
10 s...12 min
10 s...12 min
110°
110°
m
8
8
°C
–10…+50
–10…+50
IP 40
IP 40
Rated load AC15
(230 V) VA
Nominal lamp rating: incandescent (230 V) W
halogen (230 V) W
Standard contact material
Coil specification
Nominal voltage
V AC (50/60 Hz)
V AC (50/60 Hz)/DC
Rated power AC/DC
Operating range
V AC (50/60 Hz)
V AC (50/60 Hz)/DC
Technical data
Electrical life at rated load AC1
Ambient light intervention threshold
cycles
lx
Light on time after last detection
Angle of survey
Sensing area diameter
Ambient temperature range
Protection category
Approvals (according to type)
3
18 Series - PIR movement detector 10 A
Ordering information
Example: 18 series, PIR movement detector for internal installations, wall mounting, 1 NO (SPST-NO) 10 A contact, 120...230 V AC supply.
1 8 . 0
1 . 8 . 2 3 0 . 0
Series
Type
0 = Internal installation - wall mounting
1 = External installations
2 = Internal ceiling installation - surface mounting
3 = Internal ceiling installation - recessed mounting
0
0
0
Contact circuit
0 = Volt-free contact
3 = Potential free contact (18.21/31-0300 only)
Supply voltage
024 = 24 V AC/DC for types 18.21/31-0300 only
230 = 120...230 V
Supply version
8 = AC (50/60 Hz)
No. of poles
1 = Single pole switching 1 NO (SPST-NO), 10 A
Technical data
Insulation
Dielectric strength between open contacts V AC 1,000
Between supply and contact
V AC 1,500 (types 18.21...0300, 18.31...0300)
Other data
Screw torque
Max. cable size
Nm
0.5
mm2
1.5
• Following the initial power-on, and power-on following a power interruption, the detector makes a hardware-software initialisation for
approximately 30 seconds. However, the behavior of the output during this 30 seconds will depend on certain circumstances:
- If the detector was in the On state before the power interruption, and if the lighting level is (currently) below the pre-set threshold, then the
output contact will immediately close when the power is re-applied, for the time delay set by the potentiometer (irrespective of whether
movement is being detected).
- If the detector was in the Off state before the power interruption, or if the ambient light is currently over the pre-set threshold, then the detector
will not switch-on until the end of the initialisation phase (assuming movement is then detected).
Wiring diagram
Type 18.01 / 18.11
L
Type 18.21 / 18.31
L
N
N
2
2
1
1
1= ambient light
intervention
threshold
2= light on time
following last detection
1= ambient light
intervention
threshold
2= light on time
following last detection
The output relay will remain On for the pre-set time,
following the last detection of movement.
Type 18.21-0300 / 18.31-0300
L
Lux level
N
Set threshold
Detection of movement
2
4
1
1= ambient light
intervention
threshold
2= light on time
following last detection
Contact
18 Series - PIR movement detector 10 A
Mounting and orientation
Wall mounting
18.01
18.11
Surface mounting
Recessed mounting
18.21
18.31
27°
180°
27°
180°
Sensing area
18.01, 18.11 - Wall mounting
11 0
18.01 - Ceiling mounting
18.11 - Ceiling mounting
11 0
10 m
10 m
(0.35...1.4)m
Internal installations
Side view
External installations
Plan view
18.21, 18.31 - Internal ceiling installation, surface mounting or recessed mounting
Single installation
Multiple installation
Accessories
Beam limiter for 18.21 and 18.31 PIR movement detectors
Reduces the area of survey to 2 meters diameter (versus 8m) at an installation
height of 2.8 meters.
5