The HVAC system can represent up to 25% of an operators utility costs. The thermostat is the key component to
save on heating or cooling system costs. The requirements are: First it must look good on the wall, be very easy
to use and meet all the needs of the user and the equipment it is controlling. Second it must be able to adapt to
all the different control variations required (single or multi stage heat /cool systems, single or multiple fan speed
+ Heat Pump and emergency heat applications.
Finally the operator has to be able to “lock-out” local control in favor of remote control, while maintaining comfort
and eliminate energy wasting adjustments.
The installer is able to configure the iStat/Pro to control Heat pump systems, (with auxiliary or emergency heating
if necessary) gas/oil heating systems with add on cooling, plus control high and low balance points (using
external sensors as well as the number of heating and cooling stages needing precise control. It can even adapt
to manage the number of fan speeds it can control.
The operator can choose The iStat/Pro to be in programmable or manual mode with single or multiple set points. By
networking multiple iStat/Pro's with our XWEB Internet Monitoring and Control System, the iStat/Pro can be
remotely Monitored and Controlled keeping HVAC costs under control.
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
Selectable as Manual or Programmable
Up to 2 stage Heat/Cool or heat pump
Single or 3 speed fan control
Keyboard and/or Temperature Locks
Occupancy sensor input
Economizer function
24V powered with battery backup
Large backlit LCD Touch Screen Display
Remote temperature sensors available
Integrated Remote Communications
Replaces almost all 24V thermostats
XWEB Compatible
XWEB Web Server
APPROVALS:
7/11
DATE:
CAT NO.
Communicating Thermostat
iStat/Pro
Installer options
Address
Keyboard Lock
Max Heat set point
Min Cool set point
LCD Display Units
Sensor calibration
Time display
Temperature display
After Hours O/R time
Stop mode Cool temp
Stop mode Heat temp
1 Set point Dead band
Advanced fan options
Fan purge period
Mode
“W2” Output Logic
TT Terminal Function
Anti freeze
Occupied Heating SP
Occupied Cooling SP
Span stage 1
Span stage 2
Upstage Delay time
Adaptive recovery
Outside senor Calibration.
Outside Temp Cool Inhib.
Outside Temp Heat Inhib.
High Balance point
Low Balance point
Modbus Address
Filter monitor
Commissioning Mode
Economizer Function
Temp alarms
Wiring Examples
00 to 99.
5 levels.
32 to 99F
33 to 100F
Deg C / Deg F
+/- 5 deg.
12 or 24 Hour.
Room & set temp / set temp only.
0 to 12 hours
Off 32 - 95F
Off 32 - 95F
0.5 to 5
Cycle with heat and on with cool.
Commercial “Smart fan”.
Smart fan with Cool run on.
0-5 minutes
Auto season mode.
Cooling only mode.
Heating only mode.
Auxiliary Heat
Add On Heat
Emergency Heat
Outside air temp display.
Remote room temp sensor.
Average room temp sensor.
Remote override to OFF.
Occupancy mode On/Off
Off 40F.
Off 32-99F.
Off 100F.
1 -5 deg F.
1 -5 deg F.
5 ~ 60 minutes.
On or Off.
+/- 5 deg
32 - 95F
32 - 95F
32 - 95F
15 - 95F
0-99
Off to 900 hours.
On/Offf
On/Off
Hi/Low
Switch Functions
Off
Sw 1 - Fan Speed.
Sw 2 - A/C Equip.
Sw 3 - Stages
(if Sw1 =OFF)
Sw 4 - Reversing Valve
When Sw2 = ON (HP Mode)
Sw 4 - Fan Mode
When Sw2 = OFF (HC Mode)
1 Speed
(2 Heat / 2 Cool)
Heat & Cool
On
3 Speed
(1 Heat / 1 Cool)
Heat Pump
O/B Terminals
1 Stage
2 Stages
Energized
Cool (O)
Energized
Heat (B)
Fan by
Heater (HG)
Fan by
T’stat (HE)
Off
4 Minutes
Sw 6 - Operation
Manual
Thermostat
Programmable
Thermostat
Sw 7 - Min Run time
2 minutes
Sw 8 - Prog Type
Commercial
Programmable
Sw 5 - Anti cycle delay
When Sw6 = ON (programmable)
Sw 8 - # Events
When Sw6 = OFF (Manual)
Single Set Point
Terminal Designations
6 Minutes
Residential
Programmable
2 Set points
24-
24V - 0v input.
G2/Y2
24+
24V - Active input.
G3/W2
R/com
Relay common.
Fan Med / 2nd Compressor / Cool 2.
Fan High / Aux Heat. / Heat 2
T
Remote Terminal
G1
Fan low.
T
Remote Terminal
Y1
Compressor 1 / Cool 1
Modbus Data
W1
Reversing Valve / Heat 1
+
–
Modbus Data
WARRANTY
ONE YEAR
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
WEISS INSTRUMENTS, INC., 905 WAVERLY AVE., HOLTSVILLE, NEW YORK 11742 • 631.207.1200 • FAX:631.207.0900
Email: sales@weissinstruments.com
•
www.weissinstruments.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising