GigaSwitch V3
GigaSwitch V3
• 4x 10/100/1000 Mbps User Ports
• SFP and TP or
• ST or SC Uplink
ting
oun d for
M
n
e
ed
pI
Sna ols ne ion
t
o
a
T
l
tor)
No Instal m Fac
For
mm
5
4
(
Application
The GigaSwitch V3 provides the
ideal basis for the architecture of
secure, switched Gigabit Ethernet
networks in Fiber to the Office (FttO)
environment.
Snap-In Installation
The very compact design of this
switch allows a snap-in installation
(no tools needed) in standard 45
mm cable duct systems or floor
boxes without special mounting frames!
Memory Card
The optional Memory Card always
stores the complete and most actual
configuration of the switch automatically. In case of a system exchange
you just need to take out the Memory
Card of the old switch and insert it
into the new switch. During the boot
process the new switch will then take
over the old configuration from the
Memory Card. Furthermore each
Memory Card has got its own MAC
Address. As soon as a Memory Card
is inserted into a system, the active
MAC address is the MAC Address of
the Memory Card, i.e. there is no
need to change routing tables in
case of a system exchange!
Function input
• Free programmable function input
with alarm functionality
Twisted Pair User Interfaces
• TP module rotatable for
horizontal or vertical assembly
• 4 female RJ45 interfaces
(10/100/1000 Mbps)
• MDI/MDI-X Auto-Crossover and
Auto-Polarity
• Cable Diagnostic for exact
localization of errors on the
twisted pair cable links
Management
• WEB/SNMP/SSH/V.24
Management
• LLDP and CDP
• Compatibility to “Cisco Secure
Access Control Server ACS”
• Extensive security functions
SCP, SSHv2, HTTPS, RADIUS,
SNMPv3, IEEE802.1X etc.
• Integrated in ARP Guard Secure
Management
• Configuration via NexManV3
• IPv6 according to IPv6 Forum
phase 2 core specification
Energy Management
• EEE - Energy Efficient Ethernet
• ECO Mode
Mechanics
• Smallest Size (90 mm x 45 mm)
• International 45 mm Form Factor
Management
The management provides a simple
and secure configuration from a
central location. Rapid Spanning
Tree, Radius, prioritization, LLDP,
IGMP, CDP, diagnostic functions and
SNMP traps are some of the implemented features.
Features
General
• 6 Port Switch with Vario-SFP and
TP Uplink or
• 5 Port Switch with ST or SC
Uplink
• 10/100/1000 Mbps
• Store and Forward Switch,
self learning (Layer-2 switch)
• Support of Jumboframes
(10240 bytes)
Memory Card (optional)
• Memory Card with MAC-Address
• System Configuration Backup on
Memory Card and boot up with
Memory Card MAC address and
Configuration
Power Supply
• Wide Range Power Supply
100 ... 240 VAC (typ. 230 VAC)
Technical Data
GigaSwitch V3
TP SFP-I
GI(SC)
GI(ST)
pply
r su
e
w
po
VAC ithout ernet
w
h
230
r Et
ove
r
e
Pow
Memory card optional
Memory card optional
Memory card optional
Order Numbers
88303875
88303877
88303870
Memory Card with MAC Address
88300691
88300691
88300691
4x 10/100/1000 Mbps
1x 100/1000 Mbps
1x 10/100/1000 Mbps
4x 10/100/1000 Mbps
1x 1000 Mbps (SC-Duplex)
-
4x 10/100/1000 Mbps
1x 1000 Mbps (ST)
-
yes
yes
yes
yes
LAN Interfaces
User interfaces (Twisted Pair)
Uplink interfaces (SFP)
Uplink interfaces (Fixed Optic)
Uplink interfaces (Twisted Pair)
Diagnostic functions (Interfaces)
Digital Diagnostics Monitoring Interface
Twisted Pair Kabeldiagnose
General
Dimenssions [WxHxD]
Mounting
Housing
Color
Ambient temperature
Relative humidity
Weight
Power Supply
Input voltage
Power consumption
Interface connector
90 mm x 45 mm x 35 mm
Snap In
zinc diecasting / stainless steel
RAL 9010 (pure withe)
Operation: 0 ... 40 °C, Storage: -20 ... 85 °C
20 - 90 % (non-condensing)
290 g
100 … 240 VAC (typ. 230 VAC)
2,8 W (Standby) … 5,1 W (fully connected)
3-pin connector with plug-in screw terminal (up to 1.5 mm²) / (L) (N) (PE)
Functional Parameter
Switching Capacity (Backplane)
Data throughput
Switching procedure
Max. Framesize
Storage capacity
Management
Memory
Ethernet connection processor
Firmware update
FLASH configuration
SSH, HTTPS and SNMPv3 capable
Configuration- Reset button
Memory Card
Console Interface
Function input
Standards
Electrical safety (IT equipment)
Electrical conditions (EMC)
Others (abstract)
20 Gbps
> 1 400 000 Packets/Sek. per Port (FDX, bidirektional)
Store and forward, self-lerning
10 240 bytes (Support of Jumboframes)
8 192 MAC-Addresses
On-Board High-Performance Management
32 Mb RAM, 8 Mb FLASH
100 Mbps
Update in separate FLASH area, Corruption impossible
Dual Configuration, Corruption impossible
yes
yes (Configuration button deactivatable)
Memory Card with fixed MAC-Address for redundant storage of the complete switch configuration (optional)
yes
Free programmable function input with alarm functionality
EN 60950
EN 55022
CE, IEEE 802.3x (Flow Control), IEEE 802.1AB (LLDP), IEEE 802.1D (MAC Bridges),
IEEE 802.1D (Rapid Spanning Tree Protocol), IEEE 802.1D (Class of Service), IEEE 802.1X (Port-Based Network Access Control)
ANSI/TIA-1057 (Link Layer Discovery Protocol for Media Endpoint Devices),
ISO/IEC 15802-3 (Media Access Control Bridges)
Fiber Optik Parameter 1000BASE-SX
Wavelength
Dynamic (GI G50/125 µm)
Range (GI G50/125 µm)
depending on SFP version
depending on SFP version
depending on SFP version
typ. 1.310 nm
typ. 7,5 dB
typ. 550m
typ. 1.310 nm
typ. 7,5 dB
typ. 550m
Fiber Optik Parameter 1000BASE-LX
Wavelength
Dynamic (SM E9/125 µm)
Range (SM E9/125 µm)
depending on SFP version
depending on SFP version
depending on SFP version
-
-
Management Features (Extract)
GigaSwitch V3 Firmware
Access Control / Authentication Management
Admin account with Read/Write access for HTTP/HTTPS, Telnet/SSH/V.24 console and NexManV3
Access Policy Mode with disabling function for unsecure protocols, activation of SSHv2, HTTPS, SNMPv3 and "Password Checker"
Gratuitous ARP function guarantees that the switch can be reached after change of IP address
Securely encrypted transfer of configuration und firmware via SCP- Secure Copy
IPv6 according to IPv6 Forum phase 2 core specification
WEB / HTTP / HTTPS Access
WEB interface (no proxy server required), can be disabled or set to Read/Only access
TCP port number can be set for WEB access
Telnet / SSH and V.24 Console
Telnet console (no proxy server required) and Cisco-like command line interface
Telnet or V.24 console can be disabled respectively Telnet and V.24 console authentication via RADIUS server
Secure 256-bit encrypted SSH / SSL transfer and use of 1024-bit RSA keys.
SNMP Access, SNMP Traps and Syslog Messages
Configuration of switch possible via 'SNMP Set Request'
MIB-II (RFC1213) system, interface, at, ip
ETHERLIKE MIB (RFC2665) dot3StatsTable
IF MIB (RFC2863) ifXTable
BRIDGE MIB (RFC4188) dot1dBase, dot1dStp, dot1dTp
RSTP MIB (RFC4318)
RMON MIB (RFC2819) statistics
Eight IP addresses can be set as event receivers for SNMP traps, Alarm and Syslog messages
Up to 27 different event types can be enabled per receiver
Portsecurity
Loop/broadcast limiter for protection against accidental or malicious packet storms
Active loop protection with automatic disablement of short-circuited ports
Manual definition of three authorized MAC addresses per port
Automatic learning of up to three authorized MAC addresses per port
Port switches off, when an unauthorized MAC address is detected
SNMP trap/syslog message for newly detected or for unauthorized MAC address
Transparent transmission of IEEE802.1x packets can be enabled/disabled
RADIUS authentication of up to three MAC addresses per port
Port authentication according to IEEE802.1x in connection with the RADIUS server
Unauthenticated ports are switched into a freely selectable Unsecure-Default-VLAN
VLAN Support / Trunking
VLAN table selectable with up to 64 VLAN IDs,
Default-VLAN ID can be set for each port
Default-VLAN can be disabled for trunking ports
Trunking with tagging in accordance with IEEE802.1q can be enabled/disabled for each port
Prioritization of the VLAN tags selectable according to IEEE802.1p
Prioritization
Prioritization selectable per each port according to IEEE802.1p / IPv4 and IPv6
Four output queues selectable for prioritization weighting per port
4 Prioritization scheme {strict queuing}, {8,4,2,1 weighted fair queuing} , {3 strict/2,1,0 weighted}, {2,3 strict/1,0 weighted}
Discovery Protocols
LLDP (Link Layer Discovery Protocol)
CDP (Cisco Discovery Protocol)
Switch Information / Configuration
Configuration of IP parameters via DHCP and manual configuration of IP parameters possible
Configuration of IP parameters possible without pressing configuration switches (NexConV3)
Loading of a Switch Configuration or firmware via Telnet/SSH/V.24/DHCP/BOOTP console possible
Output of the running configuration in Telnet as CLI script and optional saving on an external TFTP server.
Prevention of corruption through firmware update in separate FLASH segment
Avoid corruption of configuration changes with dual configuration management
Firmware and Configuration Management via Nexans Switch Manager V3
NexManV3 authentication via RADIUS server
Download / upload of the configuration and archiving in a database on the PC
Upload of a new configuration into the switch is made On-The-Fly (no reboot required)
Archiving of the configuration in an offline database (using NexManV3)
Securely encrypted configuration via SNMPv3
Redundancy
RSTP - Rapid Spanning Tree Protocol
MSTP - Multiple Spanning Tree Protocol
Environmental Monitoring/Diagnostic/Mirroring
Display of internal operating voltages and housing temperature
SNMP trap/alarm and syslog messages, if temperature is exceeded
Logbook for permanent internal saving of syslog messages
35 counters for packets, bytes, Unicasts, Broadcasts, etc. per port
Port monitor for individual ports
Switch can be set to VLAN mirroring
Display of SFP Information: Vendorname, Part Number, Serial Number, Datecode, etc.
Display of SFP Diagnostics: TX and RX power in uW and dBm, temperature, voltage, bias current
Configurable Alarm limits for TX- and RX-Power as well as for Laser-Bias-Current
SNMP-Trap/Syslog-message activation for preset alarm limits
Other Network Protocols
IGMP Snooping (Internet Group Management Protocol) can be activated globally, IGMP protocol versions 1 or 2 can be selected
SNTP (Simple Network Time Protocol) can be activated globally
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Order Numbers
SFP 100 Pluggable Transceiver (100 Mbps)
• Fast Ethernet
• Fiber Optic LC Connector
• Digital Diagnostic Monitoring Interface
Order Numbers:
Nexans SFP 100 Transceiver GI(LC)E . . . . . . . . . . . . . . . . . . . . . . . .88646010
Nexans SFP 100 Transceiver SM(LC)E L10 . . . . . . . . . . . . . . . . . . . . .88646011
With “Digital Diagnostic Monitoring Interface” to
readout specific parameters (e.g. temperature,
optical input/output power).
SFP 1000 Pluggable Transceiver (1.000 Mbps)
• Gigabit Ethernet / Fiber Optic LC Connector
• Digital Diagnostic Monitoring Interface
Order Numbers:
Nexans SFP 1000
Nexans SFP 1000
Nexans SFP 1000
Nexans SFP 1000
Transceiver
Transceiver
Transceiver
Transceiver
GI(LC)E . . . . . . . . . . . . . . . . . . . . . . .88646015
SM(LC)E L10 . . . . . . . . . . . . . . . . . . . .88646016
SF3(LC)E L10 . . . . . . . . . . . . . . . . . . .88646073
SF5(LC)E L10 . . . . . . . . . . . . . . . . . . . 88646075
SFP 1000 TP Pluggable Transceiver (1.000 Mbps)
With “Digital Diagnostic Monitoring Interface” to
readout specific parameters (e.g. temperature,
optical input/output power).
• Gigabit Ethernet / Twisted Pair / RJ45 Connector
Order Number:
SFP 1000 Plugg. Transceiver 1000 Base T . . . . . . . . . . . . . . . . . . . . 88645917
Nexans Switch Manager (NexManV3)
• Individual generation of master configurations
(also single parameters selectable)
• Storage of configurations in a database
(up to 100 history-entries)
• Layer 2 + 3 autodiscovery
• Time for the software update can be preset
Nexans Deutschland GmbH • Advanced Networking Solutions
Bonnenbroicher Str. 2-14 • 41238 Mönchengladbach • Tel +49 (0) 2166 27-2220 • Fax +49 (0) 2166 27-2499
E-Mail: sales.ans@nexans.com • www.nexans.de/ans
Copyright © Nexans 2013 - Subject to change without prior notice - kd-1050e02
Order Numbers:
NexMan V3 (Single license) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88301908
NexMan V3 (Company license) . . . . . . . . . . . . . . . . . . . . . . . . . . . .88301909
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising