Integrated Air Conditioning System

Integrated Air Conditioning System
Integrated
Air Conditioning System
a smart solution for every building
Contents
TVR System
03
TVR System Advantage
04
TVR System Applications
05
Features - DC Inverter System
07
Features - Higher Reliability
08
Features - Enhanced Comfort
09
Features - Unique Fan Characteristics
10
Features - Easier Installation & Services
11
Mini TVR 5G Outdoor Unit Specifications
12
TVR 5G (All Inverter) Outdoor Unit Specifications
15
TVR 5G (Heat Recovery/3 Pipes) Outdoor Unit Specifications
17
TVR 5G (Heat Recovery/3 Pipes) TMS Specifications
18
TVR 5G (Inverter+Fixed) Outdoor Unit Specifications
19
TVR 5G (All Inverter-T3/High Ambient) Outdoor Unit Specifications20
Indoor Units Range
21
2
System
The new Variable Refrigerant, TVR™
A single TVR™ system fully integrates
air conditioning concept is a modular
all functions necessary for filtration,
HVAC system designed to provide the
cooling/heating, and ventilation. The
ideal climate in offices, retail establish-
indoor climate quality can be improved
ments, hotels, luxury apartments, and
when pretreated outside air is connect-
villas. Furthermore, it is equally suited
ed either directly to the indoor units or
to
introduced as a separate system. The
new
construction
and
retrofit
projects. In the global arena, TVR™
TVR™
systems have gained significant popu-
throughout the lifecycle of the project;
larity with airco ditioning professionals
from design, installation, commission-
and discerning end users who recog-
ing, operation and mainte - nance. The
nize its considerable benifits.
Independent Zone Control delivers
system
offers
advantages
energy savings for the end user by
TVR™ can be installed as the main
ensuring that the indoor units for unoc-
HVAC system in a facility or as a
cupied rooms remain off.
supplemental one that coordinates with
an existing HVAC installation to meet
different application requirements.
TVR™ (Trane Variable Refrigerant)
technology systems combine
one or
more centralized DC Inverter, aircooled
compressors and condensers connected to many indoor (fan coil) units
throughout the building.
3
Advantage
Energy Efficient:
The TVR™ system’s automatic power
consumption adjustment matches the
cooling load perfectly to the changing
needs of all the individual zones, thus
realizing energy savings. The capacity
is controlled intelligently and distributed
Energy Management
evenly over the different zones without
wasting energy.
The optional centralized control system
of TVR™ already has all the power
management data or information points
of each individual zone. Adding the
power measurement softwares allows
the user to calculate the individual
power consumption per zone, per floor
or per building. The control software will
require a Digital ammeter per condenser and the outdoor centralized controller.
4
Applications
Benefits for Installers
• TVR™ systems are easy to install; deployment and installation costs are significantly
lower. The TVR™ systems are light and can
easily fit into a standard elevator. Large
commercial equipment by comparison are
bulky and require specialist material handling
equipment.
• Since the units are modular, large cooling
systems offer compelling
benefits along the entire
value chain
Benefits for Designers
• Design Flexibility. A single condensing unit
can be connected to many indoor units of
capacities can be achieved by combining
multiple units.
• Modularity of the design also enables
stages, floor by floor or zone by zone
installation, for example when a building is
not fully occupied.
• Trane, with its range of standard TVR™
varying capacity and configurations (i.e.,
modules and sophisticated electronic
Hi wall, Cassette, Convertible and Ducted
controls aims to provide near plug-and-play
Split).
commissioning.
• The relative light weight of the system
reduces requirements for structural
reinforcement of roofs. Because ductwork
is used only for the ventilation system, it
can be smaller than the ducting required in
standard ducted systems, reducing building
height and costs.
• TVR™ systems are ideally suited to buildings
with diverse, multiple zones requiring
individual control, such as office buildings,
hospitals, or hotels.
5
Applications
Benefits for Owners
• Comfort : TVR™ Systems can be deployed
• TVR™ systems typically have multiple
compressor units. System redundancy
over several zones, each with its individual
is therefore improved, as is the ability
set point control. Since TVR™ systems use
of the system to provide cooling while
DC Inverter compressors with wide capacity
any maintenance or repair work is being
modulation, precise temperature control can
undertaken.
be achieved.
Benefits for Operators
•
eliminated in a TVR™ system, which in
a conventional ducted version can be as
much as 10 to 20% of the total airflow.
Furthermore, a TVR™ system can include
one, two or three compressors, one of which
• TVR™ systems involve lower maintenance
costs compared to other systems.
• Since these are variations of DX systems,
water treatment issues are avoided.
• Normal maintenance for a TVR™, similar to
is DC Inverter + Fixed or both inverters.
that of any DX system, consists mainly of
These factors constitute to higher system
cleaning and changing filters and cleaning
operational efficiency.
outdoor coils.
6
Features DC Inverter System
High efficiency DC Inverter compressor
Trane Air Conditioner achieves the industry's top class energy efficiency of cooling EER and heating COP
by utilizing the Brushless Reluctance DC compressor control, improved performance heat exchanger by
innovative design and numerous high performance key parts. High efficiency DC inverter compressor reduces
power consumption by 25%.
New structure enhances mid-frequency performance
Specially designed scroll profile for R410A
More compact, weight reduced by 50%
Advanced permanent magnet DC motor
improves low-frequency band performance
Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.
Centralizing winding
Efficiency-Rotor Speed Curve
Compressor efficiency
Distributing winding
New DC motor-centralized winding
Common DC motor-distributing winding
20
40
60
80
100
Rotor speed(s-1)
Smooth 180° sine wave DC Inverter
Adopting the 180° Sine Wave Inverter to smooth motor rotation greatly improves operating efficiency
compared with traditional sawtooth wave.
Common Sawtooth Wave
180° Sine Wave DC Inverter
7
Features Higher Reliability
Cycle duty operation
In one combination, any of the outdoor unit can run as the master unit and master unit can cycle in a period, to
realize the equal lifespan among the outdoor units. As a result extend the system lifespan significantly.
Priority
Priority
Priority
Priority
Backup operation
In a multiple system, if one module is failed, other modules can be backup instead of the failed one for continuing
operation.
Running state
Stand by state
Fault or stop state
Start backup operation
Precise oil control technology
5 stage oil control technology ensures every outdoor
unit & compressor’s oil always keep in the safe level,
completely solve the compressor oil lack problem.
1st stage: compressor internal oil separate
2nd stage: high efficiency oil separator (separation
efficiency up to 99%)
3rd stage: oil balance technology between compressors
4th stage: oil balance technology between modules
5th stage: intelligent system oil return program
2nd stage
4th stage
5th stage
1st stage
3rd stage
8
Features Enhanced Comfort
Quick warm-up & cool-down design
Fluctuation of room temperature
By utilizing the benefits of the inverter compressor,
the system can reach full load quickly and shorten
the warm-up and cool-down times to provide an
immediate and comfortable air solution.
Less temperature fluctuation will create a better
living environment.
1
2
Cooling operation
Night silent operation mode
activated X hours after the peak
temperature during daytime,
and it will go back to normal
operation after Y hours.
-Mode 1→X: 6 hours, Y: 10 hours
-Mode 2→X: 8 hours, Y: 10 hours
-Mode 3→X: 6 hours, Y: 12 hours
-Mode 4→X: 8 hours, Y: 8 hours
Noise dB
Night silent operation will be
Load % Capacity %
High comfort outdoor unit’s multi-choice of silent mode during the night.
Super silent operation mode can reduce sound level further, minimum 46.8dB (A).
Peak value of ambient temp.
100
50
10hrs
8hrs
Night silent Mode
noise
Max.-10dB(10Hp)
Start
08:00
14:00
Notes:
This function can be activated by setting at site.
End
22:00
08:00
Temperature(load) curve shown in the graph is just an example.
Intelligent defrosting technology
Intelligent defrosting
Heating capacity
Intelligent defrosting program will judge the defrosting
time according to the system real requirement, reduce
the heating loss by unnecessary defrosting and make
the indoor side more comfortable.
Defrosting time can be shortened to 4 min. due to the
specialized defrosting valve.
Usual defrosting
t min
Δt
Time
9
Features Unique Fan Characteristics
DC Fan Motor
Motor speed(RPM)
According to the running load and system pressure, the system controls the speed of DC fan to achieve the
minimum energy consumption and best performance.
DC inverter stepless
adjustment
AC inverter
multistep adjustment
System pressure
Fan grille
Optimized fan blade shape with new air outlet grille enhanced air flow volume
which greatly improves fan performance and decreases noise.
Standard 0~20Pa, 20~40Pa to be customised.
New profile fan blade
A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow
resistance.
Multi solenoid valves control technology
Multi solenoid valves control technology in one system.
All the solenoid valves equipped in the unit ensure
temperature-control precisely, system running steadily
and economicaly to provide a comfortable environment.
10
Features Easier Installation & Service
Simple signal line connection
Centralized controller (TCONTCCM03A/30A) can be connected from indoor side or outdoor side (XYE terminals)
at will. Only one group of communication wire of PQE, achieved both of communication for indoor & outdoor
unit. It’s more convenient for communication wiring.
PQ E
XY E
X Y E
PQ E
PQ E
PQ E
P Q E
Auto addressing
Outdoor unit can distribute addresses for indoor
unit automatically.
Wireless and wired controllers can query and
modify each indoor unit's address.
Compact design for effective use of space
Easy to transport
Compact size and light weight design minimizes the
installation footprint, reduces the installation floor load,
and is easier for transportation. For some projects the
units can even be transported through the elevator or
forklift, reduce access problem at the jobsite.
11
Mini TVR 5G Outdoor Unit Specifications
Model
4TVV0028AB000AA
Heating
Connectable
indoor unit
4TVV0042AB000AA
4TVV0048AB000AA
4TVV0055AB000AA
220-240/1/50
V/Ph/Hz
Power supply
Cooling
TVV0036AB000AA
kW
8
10.5
12.3
14
15.5
RT
2.3
2.9
3.4
3.9
4.3
Input
kW
2.05
2.68
3.25
3.95
4.52
EER
kW/kW
3.90
3.92
3.78
3.54
3.43
kW
9
11.5
13.2
15.4
17.0
RT
2.6
3.2
3.7
4.3
4.8
Input
kW
2.24
2.90
3.47
4.16
4.77
COP
kW/kW
4.02
3.97
3.80
3.70
3.56
%
45-130
45-130
45-130
45-130
45-130
4
5
6
Capacity
Capacity
Total capacity
Max. quantity
6
7
dB(A)
56
57
57
57
57
Pipe
connections
Liquid pipe
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas pipe
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф19.1
Fan motor
Type
DC
DC
DC
DC
DC
1
1
2
2
2
Sound pressure level
Quantity
Rotary
compressor
Air flow rate
m3/h
5,500
5,500
6,000
6,000
6,000
Motor output
W
170
170
85x2
85x2
85x2
1
1
1
1
1
Quantity
Capacity
kW
7
7
10
10
14
Crankcase heater
W
25
25
25
25
25
FV50S
FV50S
FV50S
FV50S
FV50S
ml
670+200
670+200
870+630
870+630
1400+250
R410A
R410A
R410A
R410A
R410A
kg
2.8
2.95
3.3
3.9
3.9
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
1,075×966×396
Packing size (W×H×D)
mm
1,120×1,100×435
Oil type
Oil charge
Refrigerant
Type
Factory charging
900×1,327×400
1,030×1,456×435
Net weight
kg
62
74
95
95
100/102
Gross weight (220V/380V)
kg
67
81
106
106
111/113
Operating
temperature range
Cooling
°C
-15~48
Heating
°C
-15~27
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 5m, level difference is zero.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1m above the floor.
*: When the * is omit, the model stands for 220-240V/1ph/50Hz unit.
When the * is R, the model stands for 380-415V/3ph/50Hz unit.
12
Mini TVR 5G Outdoor Unit Specifications
Model
4TVV0042AD000AA
Heating
Connectable
indoor unit
12.3
14
15.5
17.5
RT
3.4
3.9
4.3
5.0
Input
kW
3.25
3.95
4.52
5.30
EER
kW/kW
3.78
3.54
3.43
3.40
kW
13.2
15.4
17.0
19.0
RT
3.7
4.3
4.8
5.4
Input
kW
3.47
4.16
4.77
5.00
COP
kW/kW
3.80
3.70
3.56
3.80
%
45-130
45-130
45-130
45-130
6
6
7
9
dB(A)
57
57
57
59
Liquid pipe
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas pipe
mm
Ф15.9
Ф15.9
Ф19.1
Ф19.1
DC
DC
DC
DC
Capacity
Total capacity
Sound pressure level
Fan motor
Type
2
2
2
2
3
m /h
6,000
6,000
6,000
6,800
W
85x2
85x2
85x2
85x2
1
1
1
1
Quantity
Air flow rate
Motor output
Rotary
compressor
4TVV0060AD000AA
kW
Capacity
Max. quantity
Pipe
connections
4TVV0055AD000AA
380-415/3/50
V/Ph/Hz
Power supply
Cooling
4TVV0048AD000AA
Quantity
Capacity
kW
10
10
14
14
Crankcase heater
W
25
25
25
25
FV50S
FV50S
FV50S
FV50S
870+630
870+630
1400+250
1400+250
R410A
R410A
R410A
R410A
kg
3.3
3.9
3.9
4.5
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
900×1,327×400
Packing size (W×H×D)
mm
1,030×1,456×435
Oil type
Oil charge
Refrigerant
ml
Type
Factory charging
Net weight
kg
95
95
100/102
107
Gross weight (220V/380V)
kg
106
106
111/113
118
Operating
temperature range
Cooling
°C
-15~48
Heating
°C
-15~27
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 5m, level difference is zero.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1m above the floor.
*: When the * is omit, the model stands for 220-240V/1ph/50Hz unit.
When the * is R, the model stands for 380-415V/3ph/50Hz unit.
13
Mini TVR 5G Outdoor Unit Specifications
Model
4TVV0068AD000AA
Capacity
kW
61.5
67.0
85.0
RT
17.5
19.0
24.1
Power input
kW
18.8
20.8
26.6
kW/kW
3.27
3.22
3.20
Capacity
kW
69.0
75.0
95.0
RT
19.6
21.3
27.0
Power input
kW
17.9
19.8
24.4
kW/kW
3.86
3.79
3.89
%
50-130
50-130
50-130
36
39
32
63
64
EER
Heating
COP
Connectable
indoor unit
Total capacity
Max. quantity
Sound pressure level
dB(A)
Pipe
connections
Liquid pipe
mm
Gas pipe
mm
Fan motor
Type
2
4
27,900
Air flow rate
m3/h
23,000
Motor output
W
625+450
ESP
Pa
0~20 (default)
Pa
20~40 (customized)
Quantity
kW
Crankcase heater
W
Oil charge
Fixed inverter Quantiy
scroll
Capacity
compressor
Crankcase heater
11.8
30×2
27.6×3
500
ml
2
5
kW
17.1×2
20.9×2
W
33×2
33×2
27.6×4
FVC68D
FVC68D
FVC68D
500×2
1100×2
500×5
R410A
R410A
R410A
18.5
18.5
21
ml
Type
Factory charging
31.59
FVC68D
Oil type
Oil charge
750+450+380×2
1
Capacity
Oil type
Refrigerant
DC×2+AC×2
DC+AC
Quantity
DC inverter
compressor
4TVV0089AD000AA
380-415/3/50
V/Ph/Hz
Power supply
Cooling
4TVV0077AD000AA
kg
17.1×5
4.4/2.6
Design pressure (High/Low)
MPa
Net dimension (W×H×D)
mm
Packing size (W×H×D)
mm
Net weight
kg
385
390
655
Gross weight
kg
400
405
690
Operating
temperature
range
1,585×1,615×765
2,540×1,615×765
1,650×1,810×840
2,600×1,800×825
Cooling
°C
-50~48
Heating
°C
-200~27
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27 oC DB/19oC WB; Outdoor temperature 35 oC DB/24oC WB.
Heating: Indoor temperature 20 C DB/15oC WB; Outdoor temperature 7 oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.
o
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
14
TVR 5G (All Inverter) Outdoor Unit Specifications
Model
4TVV0086BD000AA
Power supply
Cooling
V/Ph/Hz
kW
RT
7.2
8.0
9.5
Power input
kW
5.88
7.05
8.79
kW/kW
4.29
3.97
3.81
kW
27
31.5
37.5
RT
7.7
9.0
10.7
kW
6.15
7.55
8.99
Capacity
Power input
COP
Connectable
indoor unit
Total capacity
Fan motor
4.39
4.17
4.17
50-130
50-130
50-130
13
16
20
dB(A)
57
59
Liquid pipe
mm
Φ9.53
Φ12.7
Gas pipe
mm
Φ22.2
Φ25.4
Oil balance pipe
mm
Φ6
Φ6
DC
DC
Type
1
2
m3/h
11,242
13,000
Motor output
W
750
ESP
Pa
0-20 (default)
0-20 (default)
Pa
20-40 (customized)
20-40 (customized)
Outdoor air flow
Quantity
560+380
1
2
Capacity
kW
31.59
31.59+11.80
Crankcase heater
W
27.6×2
27.6×4
Oil type
Oil charge
Refrigerant
33.5
%
Quantity
DC inverter
compressor
28.0
25.2
kW/kW
Max. quantity
Sound pressure level
Pipe
connections
4TVV0115BD000AA
380-415/3/50
Capacity
EER
Heating
4TVV0096BD000AA
ml
Type
FVC68D
FVC68D
500
500+500
R410A
R410A
kg
10
12
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
960×1,615×765
1,250×1,615×765
Packing size (W×H×D)
mm
1,025×1,790×830
1,305×1,790×820
kg
212
288
Gross weight
kg
227
Operating
Cooling
temperature range
Heating
°C
-5~48
°C
-20~24
Factory charging
Net/Gross weight
308
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical
manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
15
30
TVR 5G (All Inverter) Outdoor Unit Specifications
Model
4TVV0140BD000AA
Power supply
Cooling
Power input
EER
Heating
Capacity
Power input
COP
Connectable
indoor unit
Total capacity
Fan motor
kW
40.0
45.0
50.0
RT
11.4
12.8
14.2
kW
11.30
13.25
14.79
kW/kW
3.54
3.50
3.45
kW
45.0
50.0
56.0
RT
12.8
14.2
15.9
kW
11.19
12.79
14.40
kW/kW
4.02
3.91
3.89
%
50-130
50-130
50-130
Max. quantity
23
26
29
dB(A)
61
62
62
Liquid pipe
mm
Φ12.7
Φ12.7
Φ15.9
Gas pipe
mm
Φ25.4
Φ28.6
Φ28.6
Oil balance pipe
mm
Φ6
Φ6
Φ6
Sound pressure level
Pipe
connections
Type
DC
Quantity
2
3
m /h
15,620
Motor output
W
560+380
ESP
Pa
0-20 (default)
Pa
20-40 (customized)
Outdoor air flow
DC inverter
compressor
Quantity
2
Capacity
kW
Crankcase heater
W
31.59+11.80
27.6×4
Oil type
Oil charge
Refrigerant
4TVV0182BD000AA
380-415/3/50
V/Ph/Hz
Capacity
4TVV0155BD000AA
FVC68D
ml
500+500
Type
Factory charging
R410A
kg
15
15
Design pressure (High/Low)
MPa
4.4/2.6
Net dimension (W×H×D)
mm
1,250×1,615×765
Packing size (W×H×D)
mm
1,305×1,790×820
kg
288
Gross weight
kg
308
Operating
Cooling
temperature range
Heating
°C
-5~48
°C
-20~24
Net/Gross weight
17
288
310
308
330
Notes: Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB. Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical
manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor. *18HP can be customized.
16
TVR 5G (Heat Recovery/3pipes)
Outdoor Unit Specifications
Model
4TVR0086BD000AA
Power supply
Cooling
25.2
28.0
33.5
40.0
45.0
RT
7.2
8.0
9.5
11.4
12.8
5.73
6.67
8.07
11.30
13.24
4.40
4.20
4.15
3.54
3.40
Capacity
kW
27.0
31.5
37.5
45.0
50.0
RT
7.7
8.9
10.7
12.8
14.2
Power input
kW
6.00
7.33
8.72
11.19
12.79
Total capacity
kW/kW
4.50
4.30
4.30
4.02
3.91
%
50-130
50-130
50-130
50-130
50-130
26
13
16
20
23
dB(A)
57
57
58
60
60
Liquid pipe
mm
Ф9.53
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Low pressure gas pipe
mm
Ф22.2
Ф22.2
Ф25.4
Ф28.6
Ф28.6
High pressure gas pipe
High pressure gas
balance pipe
mm
Ф19.1
Ф19.1
Ф19.1
Ф22.2
Ф22.2
mm
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Ф19.1
Oil balance pipe
mm
Ф6
Ф6
Ф6
Ф6
Ф6
DC
DC
DC
DC
DC
2
2
2
2
2
m3/h
12,000
12,000
13,000
15,000
15,000
Motor output
W
420
420
420
750
ESP
Pa
Max. quantity
Sound pressure
level
Fan motor
kW
kW
COP
Pipe
connections
Type
Quantity
Air flow rate
Quantity
750
0-20 (default)
0-20 (default)
20-40 (customized)
Pa
DC inverter
compressor
4TVR0155BD000AA
kW/kW
EER
Connectable
indoor unit
4TVR0140BD000AA
380-415/3/50
V/Ph/Hz
Capacity
Power input
Heating
4TVR0096BD000AA 4TVR0115BD000AA
20-40 (customized)
1
1
1
2
2
31.59+11.8
Capacity
kW
31.59
31.59
31.59
31.59+11.8
Crankcase heater
W
30×2
30×2
30×2
30×4
30×4
FVC68D
FVC68D
FVC68D
FVC68D
FVC68D
Oil type
ml
500
500
500
500+500
500+500
R410A
R410A
R410A
R410A
R410A
kg
10
10
10
13
13
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
Packing size (W×H×D)
mm
255
303
303
273
322
322
Oil charge
Refrigerant
Type
Factory charging
Net weight
1,250×1,615×765
1,305×1,790×820
kg
255
255
Gross weight
kg
273
273
Operating
Cooling
temperature range
Heating
Simultaneous
cooling and heating
°C
-5~48
°C
-20~24
°C
-5~24
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical
manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
17
TVR 5G (Heat Recovery/3pipes)
TMS Specifications
TMS equipment which can be connected multiple indoor units
Model
TMSBOX01A
TMSBOX02A
TMSBOX06A
TMSBOX04A
Max. indoor unit groups
1
2
4
6
Max. number of each group indoor units
4
4
4
4
4×1=4
4×2=8
4×4=16
4×6=24
Max. number of all downstream indoor units
Max. capacity of each group indoor units
kW
16
16
16
16
Total capacity of all downstream indoor units
kW
≤16
≤28
≤45
≤45
Liquid pipe
mm
Φ9.53
Φ12.7
Φ15.9
Φ15.9
Connect to
High pressure gas pipe
outdoor unit
mm
Φ15.9
Φ19.1
Φ22.2
Φ22.2
Low pressure gas pipe
mm
Φ19.1
Φ25.4
Φ31.8
Φ31.8
Liquid pipe
mm
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Gas pipe
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
dB(A)
33
33
33
40
Net dimension (W×H×D)
mm
630×225×600
630×225×600
960×225×600
960×225×600
Packing size (W×H×D)
mm
725×325×685
725×325×685
1055×325×685
1055×325×685
Net weight
kg
18
19.5
31
35
Gross weight
kg
25
27
40
44.5
Piping
connections
Connect to
indoor unit
Sound pressure level
TMS equipment which can be connected only one indoor unit
TMSEBOX02A
Model
TMSEBOX04A
1
1
kW
20~28
40~56
mm
Φ12.7
Φ15.9
Connect to
High pressure gas pipe
outdoor unit
mm
Φ19.1
Φ22.2
Low pressure gas pipe
mm
Φ25.4
Φ31.8
Liquid pipe
mm
Φ9.53
Φ9.53
Gas pipe
mm
Φ15.9
Φ15.9
dB(A)
33
33
Net dimension (W×H×D)
mm
630×225×600
960×225×600
Packing size (W×H×D)
mm
725×325×685
1055×325×685
Net weight
kg
19.5
31
Gross weight
kg
27
40
Max. number of all downstream indoor units
Capacity of downstream indoor unit
Liquid pipe
Piping
connections
Connect to
indoor unit
Sound pressure level
Note:
Sound values are measured in a semi-anechoic room, at a position 1m below the MS equipment in mode switch condition.
It is not recommended to install in the place where high noise performance is required.
41
18
Outdoor Unit Specifications
TVR 5G (Inverter+Fixed)
Outdoor Unit Specifications
TVR 5G (Heat Pump Series)
Model
4TVV0086AD000AA 4TVV0096AD000AA 4TVV0115AD000AA 4TVV0140AD000AA 4TVV0155AD000AA
Power supply
Cooling
Heating
Connectable
indoor unit
kW
25.2
28
33.5
40
45
RT
7.2
8
9.5
11.4
12.8
Input
kW
5.87
7.2
9.05
12.31
14.02
EER
kW/kW
4.29
3.89
3.7
3.42
3.40
kW
27
31.5
37.5
45
50
RT
7.7
8.9
10.7
12.8
14.2
Input
kW
6.15
7.61
8.99
11.19
12.79
COP
kW/kW
4.39
4.14
4.17
4.02
3.91
%
50-130
50-130
50-130
50-130
50-130
17
21
26
30
34
Capacity
Total capacity
Max. quantity
Sound pressure level
Pipe
connections
Fan motor
dB(A)
57
57
58
60
60
Liquid pipe
mm
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Gas pipe
mm
Ф22.2
Ф25.4
Ф28.6
Ф28.6
Ф28.6
Oil balance pipe
mm
Ф6
Ф6
Ф6
Ф6
Ф6
DC
DC
DC
DC
DC
1
1
2
2
2
Type
Quantity
DC inverter
compressor
Air flow rate
m3/h
11,700
11,700
15,600
15,600
15,600
Motor output
W
420
420
360×2
360×2
360×2
ESP
Pa
0-20 (default)
0-20 (default)
0-20 (default)
Pa
20-40 (customized)
20-40 (customized)
20-40 (customized)
Quantity
Capacity
kW
Crankcase heater
W
Oil type
Oil charge
Fixed scroll
compressor
ml
Quantity
1
1
1
1
1
11.8
11.8
11.8
11.8
11.8
27.6×2
27.6×2
27.6×2
27.6×2
27.6×2
FVC68D
FVC68D
FVC68D
FVC68D
FVC68D
500
500
500
500
500
1
1
1
2
2
17.1×2
Capacity
kW
15.39
17.1
17.1
15.39×2
Crankcase heater
W
27.6
27.6
27.6
27.6×2
27.6×2
FVC68D
FVC68D
FVC68D
FVC68D
FVC68D
500
500
500
500×2
500×2
R410A
Oil type
Oil charge
Refrigerant
380-415/3/50
V/Ph/Hz
Capacity
ml
Type
R410A
R410A
R410A
R410A
kg
10
10
12
15
15
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
Packing size (W×H×D)
mm
Factory charging
960×1,615×765
1,250×1,615×765
1,025×1,790×830
1,305×1,790×820
Net weight
kg
245
245
275
325
325
Gross weight
kg
260
260
295
345
345
Operating
Cooling
temperature range
Heating
°C
-5~48
°C
-20~24
Notes: Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical
manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
19
TVR 5G (All Inverter-T3/High Ambient)Outdoor Unit Specifications
4TVVT086BD000AA
Model
Power supply
Cooling(*1)
Heating(2*)
Connectable
indoor unit
Fan motor
kW
25.2
28.0
33.5
40.0
45.0
Capacity**
kW
23.6
26.3
30.7
Input*
kW
5.88
Input**
kW
EER*
kW/kW
EER**
50.0
37.6
41.2
45.8
7.05
8.79
11.30
12.85
14.49
6.37
7.64
11.25
12.24
16.46
18.55
4.29
3.97
3.81
3.54
3.50
3.45
kW/kW
3.72
3.45
2.73
3.07
2.51
2.47
Capacity*
kW
27.0
31.5
37.5
45.0
50.0
56.0
Input*
kW
6.15
7.55
8.99
11.19
12.79
14.40
COP*
kW/kW
4.39
4.17
4.17
4.02
3.91
3.89
Total capacity
50~130
%
Max. quantity
dB(A)
13
16
20
23
26
29
57
57
59
61
62
62
Liquid pipe
mm
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Ф15.9
Ф19.1
Gas pipe
mm
Ф25.4
Ф25.4
Ф31.8
Ф31.8
Ф31.8
Ф31.8
Oil balance pipe
mm
Ф6.4
Ф6.4
Ф6.4
Ф6.4
Ф6.4
Ф6.4
DC
DC
DC
DC
DC
DC
Type
1
1
2
2
2
2
Air flow rate
3
m /h
11,242
11,242
15,620
15,620
15,620
15,770
Motor output
W
454
454
232x2
383x2
383x2
560x2
ESP
Pa
0~20 (default)
Pa
20~40 (optional)
Quantity
DC inverter
compressor
4TVVT140BD000AA 4TVVT155BD000AA 4TVVT182BD000AA
380-415/3/50
V/Ph/Hz
Capacity*
Sound pressure
level
Pipe
connections
4TVVT096BD000AA 4TVVT115BD000AA
Quantity
Capacity
kW
Crankcase heater
W
Oil type
1
1
1+1
1+1
1+1
1+1
31.59
31.59
31.59+11.8
31.59+11.8
31.59+11.8
31.59 +31.59
27.6×2
27.6×2
27.6×2x2
27.6×2
27.6×2
27.6x2
FVC68D
FVC68D
FVC68D+FVC68D
FVC68D+FVC68D
FVC68D+FVC68D
FVC68D+FVC68D
500
500
500+500
500+500
500+500
500+500
R410a
R410a
R410a
R410a
R410a
R410a
kg
10
10
12
15
15
16
Design pressure (High/Low)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Net dimension (W×H×D)
mm
Packing size (W×H×D)
mm
Oil charge
Refrigerant
ml
Type
Factory charging
960×1,615×765
1,250×1,615×765
1,025×1,790×830
1,305×1,790×820
Net weight
kg
212
212
288
288
288
310
Gross weight
kg
220
220
300
308
308
330
Operating
temperature range
Cooling
°C
-5~54
Heating
°C
-20~24
Notes:
Heating
20
Indoor Units Range
Model number
TYPE OF UNITS
BTU/H
Capacity (kW)
4TVL0007CB0WEAA
New Ducted -Low Static Pressure
7 500
2.2
4TVL0009CB0WEAA
New Ducted -Low Static Pressure
9 500
2.8
4TVL00012CB0WEAA
New Ducted -Low Static Pressure
12 500
3.6
4TVL00015CB0WEAA
New Ducted -Low Static Pressure
15 000
4.5
4TVL00019CB0WEAA
New Ducted -Low Static Pressure
19 000
5.6
2.2
4TVD0007CB0WEAA
Ducted -Medium Static Pressure
7 500
4TVD0009CB0WEAA
Ducted -Medium Static Pressure
9 500
2.8
4TVD0012CB0WEAA
Ducted -Medium Static Pressure
12 300
3.6
4.5
4TVD0015CB0WEAA
Ducted -Medium Static Pressure
15 000
4TVD0019CB0WEAA
Ducted -Medium Static Pressure
19 000
5.6
4TVD0024CB0WEAA
Ducted -Medium Static Pressure
24 300
7.1
4TVD0027CB0WEAA
Ducted -Medium Static Pressure
24 700
8.0
4TVD0031CB0WEAA
Ducted -Medium Static Pressure
31 000
9.0
4TVD0038CB0WEAA
Ducted -Medium Static Pressure
38 000
11.2
4TVD0048CB0WEAA
Ducted -Medium Static Pressure
48 000
14.0
4TVH0024CB0WEAA
Ducted -High Static Pressure
24 200
7.1
4TVH0027CB0WEAA
Ducted -High Static Pressure
27 300
8.0
4TVH0030CB0WEAA
Ducted -High Static Pressure
30 700
9.1
4TVH0038CB0WEAA
Ducted -High Static Pressure
38 200
11.2
4TVH0048CB0WEAA
Ducted -High Static Pressure
48 000
14.0
4TVH0055CB0WEAA
Ducted -High Static Pressure
55 000
16.0
4TVH0075CB0WEAA
Ducted -High Static Pressure
75 000
20.0
4TVH0085CB0WEAA
Ducted -High Static Pressure
85 300
25.0
4TVH0096CB0WEAA
Ducted -High Static Pressure
95 500
28.0
4TVH0140CB0WEAA
Ducted -High Static Pressure
140 000
40.0
4TVH0155CB0WEAA
Ducted -High Static Pressure
155 000
45.0
4TVH0190CB0WEAA
Ducted -High Static Pressure
190 000
56.0
12.5
4TVF0042CB0WEAA
Ducted -Full Fresh Air
42 000
4TVF0048CB0WEAA
Ducted -Full Fresh Air
48 000
14.0
4TVF0075CB0WEAA
Ducted -Full Fresh Air
75 000
20.0
4TVF0085CB0WEAA
Ducted -Full Fresh Air
85 300
25.2
4TVF0096CB0WEAA
Ducted -Full Fresh Air
95 500
28.0
4TVA0009CB0REAA
1-Way-Cassette
9 500
2.8
4TVA0012CB0REAA
1-Way-Cassette
12 200
3.6
4TVA0015CB0REAA
1-Way-Cassette
15 300
4.5
4TVA0019CB0REAA
1-Way-Cassette
19 000
5.6
21
09
Indoor Units Range
Model number
TYPE OF UNITS
BTU/H
Capacity (kW)
4TVE0007CB0REAA
2-Way-Cassette
7 500
2.2
4TVE0009CB0REAA
2-Way-Cassette
9 500
2.8
4TVE0012CB0REAA
2-Way-Cassette
12 200
3.6
4TVE0015CB0REAA
2-Way-Cassette
15 300
4.5
4TVE0018CB0REAA
2-Way-Cassette
18 900
5.6
4TVE0024CB0REAA
2-Way-Cassette
24 200
7.1
4TVB0007CB0REAA
4 Way-Cassette Compact 360°
7 500
2.2
4TVB0009CB0REAA
4 Way-Cassette Compact 360°
9 550
2.8
4TVB0012CB0REAA
4 Way-Cassette Compact 360°
12 300
3.6
4TVB0015CB0REAA
4 Way-Cassette Compact 360°
15 300
4.5
4TVC0009CB0REAA
4 Way-Cassette Standard
9 500
2.8
4TVC0012CB0REAA
4 Way-Cassette Standard
12 200
3,6
4TVC0015CB0REAA
4 Way-Cassette Standard
15 300
4,5
4TVC0018CB0REAA
4 Way-Cassette Standard
18 900
5,6
4TVC0024CB0REAA
4 Way-Cassette Standard
24 200
7.1
4TVC0027CB0REAA
4 Way-Cassette Standard
27 300
8.0
4TVC0030CB0REAA
4 Way-Cassette Standard
30 700
9.0
4TVC0034CB0REAA
4 Way-Cassette Standard
34 100
10.0
4TVC0038CB0REAA
4 Way-Cassette Standard
38 200
11.2
4TVC0048CB0REAA
4 Way-Cassette Standard
48 000
14.0
4TVW0007CB0REBA
Hi Wall S series
7 500
2.2
4TVW0009CB0REBA
Hi Wall S series
9 500
2.8
4TVW0012CB0REBA
Hi Wall S series
12 300
3.6
4TVW0015CB0REBA
Hi Wall S series
15 400
4.5
4TVW0018CB0REBA
Hi Wall S series
19 000
5.6
4TVW0007CBHREBA
Hi Wall S series with Electric Heat
7 500
2.2
4TVW0009CBHREBA
Hi Wall S series with Electric Heat
9 500
2.8
4TVW0012CBHREBA
Hi Wall S series with Electric Heat
12 300
3.6
4TVW0015CBHREBA
Hi Wall S series with Electric Heat
15 400
4.5
4TVW0018CBHREBA
Hi Wall S series with Electric Heat
19 000
5.6
4TVW0007CB0REAA
Hi Wall C series
7 500
2.2
4TVW0009CB0REAA
Hi Wall C series
9 600
2.8
4TVW0012CB0REAA
Hi Wall C series
12 300
3.6
4TVW0015CB0REAA
Hi Wall C series
15 500
4.5
4TVW0018CB0REAA
Hi Wall C series
19 000
5.6
22
Indoor Units Range
Model number
TYPE OF UNITS
BTU/H
Capacity (kW)
4TVW0007CBHREAA
Hi Wall C series with Electric Heat
7 500
2.2
4TVW0009CBHREAA
Hi Wall C series with Electric Heat
9 600
2.8
4TVW0012CBHREAA
Hi Wall C series with Electric Heat
12 300
3.6
4TVW0015CBHREAA
Hi Wall C series with Electric Heat
15 500
4.5
4TVW0018CB0REAA
Hi Wall C series with Electric Heat
19 000
5.6
4TVW0024CB0REAA
Hi Wall R series
24 200
8.0
4TVW0027CB0REAA
Hi Wall R series
27 300
9.0
4TVW0031CB0REAA
Hi Wall R series
31 800
10.0
4TVX0012CB0REAA
Convertible
12 200
3.6
4TVX0015CB0REAA
Convertible
15 300
4.5
4TVX0018CB0REAA
Convertible
19 100
5.6
4TVX0024CB0REAA
Convertible
24 200
7.1
4TVX0027CB0REAA
Convertible
27 300
8.0
4TVX0030CB0REAA
Convertible
30 700
9.0
4TVX0038CB0REAA
Convertible
38 200
11.2
4TVX0048CB0REAA
Convertible
48 000
14.0
4TVX0055CB0REAA
Convertible
54 600
16.00
4TVG0007CB0REAA
Console
7 500
2.2
4TVG0009CB0REAA
Console
9 500
2.8
4TVG0012CB0REAA
Console
12 300
3.6
4TVG0015CB0REAA
Console
15 300
4.5
26
23
09
Literature Order Number
TVR5G-50Hz-SLB001-R410A-EN
Dat e
August 2014
Supersedes
NEW
Trane has a policy of continuous product and product data improvement and reserves the right to
change design and specifications without notice. © 2009 Trane
24
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising