advertisement
AX-12 Installation Guide Rev.B.doc
2016-12-15
A X - 1 2 v 1 . 0
R S 4 8 5 B u s P r o t e c t i o n
M o d u l e
C o n s t r u c t i o n a n d a p p l i c a t i o n
AX-12 is a protection module dedicated to RS485 bus exposed to high electric interferences. AX-12 has been designed for RACS system and should not be used in other RS485 systems.
I n s t a l l a t i o n
The AX-12 should be installed according to fig.1 below. All electrical connections should be carried out with power supply off. It's recommended to connect single
AX-12 module every 50-100m of RS485 cable.
Fig.1 Typical connection diagram of AX-12
Power supply
Specification
Nominal 12VDC, min./max. range 10-15VDC
Average current consumption 5 mA
Clamping voltage
Working temperature range
-0.7 - +8 VDC
-25...+70 ºC
Relative humidity
Dimensions H x W x D
Weight
0 – 95 % (non-condensing)
35 x 40 x 14.5 mm
~ 5g
AX-12
Ordering Information
RS485 bus protection module
Product version Released
AX-12 v1.0 12/2014
Product History
Description
The first commercial product version
This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health. The user is obliged to deliver equipment to the designated collection points of electric and electronic waste. For detailed information on recycling, contact your local authorities, waste disposal company or point of purchase. Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment. Weight of the equipment is specified in the document.
Contact:
Roger sp. z o.o. sp.k.
82-400 Sztum
Gościszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: [email protected]
Web: www.roger.pl