UCG75-12 - ULTRACELL
UCG75-12
12V 75AH
Deep Cycle Gel
UCG75-12
Physical Specification
Awaiting Image
Part Number
UCG75-12
Length
259 ± 2 mm
Width
168 ± 2 mm
Container Height
208 ± 2 mm
Total Height (with terminal)
214 ± 2 mm
Approx Weight
22.3 kg
Specifications
Nominal Voltage
12V
Nominal Capacity (10HR)
75.0AH
Terminal Type
Standard Terminal
F6
Container Material
Standard Option
ABS
Rated Capacity
20hr, 1.80V/cell, 25°C
80.4 AH/4.02A
10hr, 1.80V/cell, 25°C
75.0 AH/7.50A
5hr, 1.75V/cell, 25°C
65.8 AH/13.2A
1hr, 1.60V/cell, 25°C
48.5 AH/48.5A
Max Discharge Current
900A (5s)
Internal Resistance
Approx 6.6m
Discharge Characteristics
Operating Temp. Range
Discharge:
-15°C~50°C
Charge:
0°C~40°C
Storage:
-15°C~40°C
Nominal Operating Temp. Range
25±3°C
Cycle Use
Initial Charging Current less than 22.5A. Voltage
14.4V ~ 15.0V at 25°C Temp. Coefficient -30mV/°C
Standby Use
No limit on Initial Charging Current Voltage
13.5V ~ 13.8V at 25°C Temp. Coefficient -20mV/°C
Capacity affect by Temperature
40°C
103%
25°C
100%
0°C
86%
Design Floating Life at 20°C
15 Years
Self Discharge
Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required.
For higher temperatures the time interval will be shorter.
Dimensions
F6 Terminal
40.5
208 2
214 2
6 [0.236]
1
Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
www.ultracell.co.uk
210
259
168 2
16 [0.63]
M6 [0.236]
2
2
Revised: 25 Nov 2015
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001
UCG75-12
12V 75AH
Deep Cycle Gel
Constant Current Discharge (Amperes) at 25°C
F.V/Tim e
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
204.9
174.2
153.9
111.6
89.3
72.7
45.3
35.4
28.8
23.4
20.6
16.8
14.0
7.97
1.80V/cell
258.3
207.3
179.1
130.1
103.0
80.9
49.2
37.9
30.6
25.1
22.0
17.8
14.8
8.03
1.75V/cell
280.3
224.3
191.1
134.4
106.3
84.4
50.9
38.5
31.2
25.7
22.6
18.1
15.0
8.10
1.70V/cell
301.3
237.7
199.7
139.4
110.3
86.8
52.7
39.5
31.9
26.3
23.0
18.3
15.1
8.24
1.65V/cell
322.8
251.1
211.1
146.4
112.6
89.4
54.1
41.1
33.0
27.0
23.5
18.6
15.4
8.34
1.60V/cell
344.5
265.4
222.6
153.0
116.3
91.8
55.5
42.1
33.9
27.7
23.9
18.8
15.6
8.37
F.V/Tim e
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
109.8
92.4
80.7
58.1
46.1
37.4
23.3
18.1
14.7
11.9
10.4
8.50
7.08
3.98
1.80V/cell
140.3
111.6
95.4
68.6
53.7
41.9
25.4
19.5
15.7
12.8
11.2
9.02
7.50
4.02
1.75V/cell
154.2
121.9
102.7
71.2
55.7
43.9
26.3
19.9
16.0
13.2
11.5
9.17
7.58
4.06
1.70V/cell
168.0
130.2
107.9
74.1
57.9
45.3
27.4
20.4
16.5
13.5
11.7
9.30
7.65
4.13
1.65V/cell
181.4
138.4
114.6
78.1
59.4
46.8
28.1
21.3
17.0
13.9
12.0
9.45
7.81
4.19
1.60V/cell
196.9
148.1
122.1
82.5
61.9
48.5
29.1
22.0
17.6
14.3
12.2
9.54
7.89
4.21
Constant Power Discharge (Watts) at 25°C
Discharge Characteristics
6V Battery12V Battery
(V)
(V)
Terminal Voltage(V)
6.5
Float Charging Characteristics
Charg in g Characteri sti cs
Temperature 250C
Charge
Volume
13.0
6.0
12.0
5.5
11.0
5.0
0.1C 0.054C
0.214C
10.0
0.365C
3.8C
2.6C
1.1C
0.646C
Charging
Current
(A)
(V/cell)
100
0.1C
2.5
80
0.08C
2.4
60
0.06C
2.3
40
0.04C
2.2
4.0
20
0.02C
2.1
8.0
1
4
2
20
6 8 10
min
40 60
Charge At 0.1C Amp initial charging current and 2.45V/Cell Constant
o
Voltage at 25C
Charged Volume
Charge Voltage
(Constant 2.45v/cell)
After 50% Discharge
9.0
4.5
Charged
Voltage
%
120
2
4
6 8 10
H
0C
20
After 100% Discharge
Charging Current
(initial at 0.1c Amp)
0
4
8
12
16
20
24
28
Charging Time(hours)
Discharge Time
Temperature Effects in Relation to Battery Capacity
Effect of Temperature on Long Term Float Life
120
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 2.45V/cell,max. 0.25CA;
Charging volume:125% of discharged capacity.
0.1CA
0.12CA
0.21CA
100
120
Capacity (%)
100
Capcity(%)
80
60
100%
DOD
50%
DOD
30%
DOD
40
80
1CA
60
2CA
3CA
40
20
20
0
-20
0
0
200
400
600
800
1000 1200 1400 1600 1800
-10
10
0
Number of Cycles
Cycle Life in Relation to Depth of Discharge
100
0
80
Remaining Capacity(%)
Extracted capacity in %
90
70
60
50
40
30
20
10
800
1200
1600
2000
2400
2800
3200
3600
4000
100C
80
25 C
40
50
0
No supplementary charge required
(carry out supplementary charge before use if 100% capacity is required).
Supplementary charge required before use.
B
300C
40 C
40
Optional charging method as below:
1. Charged for above 3 days at limited current 0.25C and constant voltage 2.25V/cell
2. Charged for above 20 hours qat limited current 0.025C and constant voltage 2.45V/cell
3. Charged for 8~10 hours at limited current 0.05CA.
Supplementary charge may often fail to recover the capacity.
the battery should never be left standing until this is reached.
C
20
0
2
4
Number of Cycles
2
A
0
60
0
400
30
Self Discharge Characteristics
Acc.to IEC 896-2 (25 C / 77 F)
0
100
20
Temperature(0C)
Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
www.ultracell.co.uk
6
8
10
12
Storage Time(Months)
Revised: 25 Nov 2015
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project