ATX PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets

ATX PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets
PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets
Flameproof
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD or II 2 G
IP66 or IP55 – IK10
Applications
16 Amp Plug and Socket
Features
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
32 Amp Plug and Socket
80 Amp and 125 Amp Plug and Socket
• Wall Sockets — 125 A:
—1 x M50 threaded entry (on the top side).
—Connection via 8 mm (0.32 in) diameter lug terminals (not
supplied).
—Internal earth through 35 mm2 (0.054 in2) connection and
external earth through 6 mm (0.24 in) diameter screws.
• Plugs — 16 A:
—1 cable entry through integrated M25 cable gland
– 9 to 12 mm (9 to 12 in) diameter for the 2P+E plug
– 12 to 15 mm (0.47 to 15 in) diameter for the 3P+E plug
– 15 to 17 mm (0.59 to 0.70 in) diameter for the 3P+N+E plug
—Connection on 2.5 mm2 (0.004 in2) maximum terminals.
• Plugs — 32 A:
—1 cable entry via integrated cable gland diameter 17 to 22
mm (0.70 to 0.87 in).
—Connection on 6 mm2 (0.009 in2) maximum terminals.
• Plugs — 80 A:
—1 cable entry via supplied cable gland diameter 18 to 28 mm
(0.71 to 1.1 in).
—Connection on 16 mm2 (0.025 in2) maximum terminals.
• Plugs — 125 A:
—1 cable entry via supplied cable gland diameter 30 to 36 mm
(1.18 to 1.42 in).
—Connection on 35 mm2 (0.054 in2) maximum terminals.
Standard Materials
• 16 A socket outlet body and socket: gray painted marine grade
aluminum alloy
• 32 A socket outlet body: gray painted marine grade aluminum
alloy body
• 32 A socket outlet flush socket: cast iron
• 80 and 125 A socket outlet body and socket: painted cast iron
with marine anti-corrosion treatment
• Plugs: gray painted marine grade aluminum alloy
1389
Plugs and Receptacles
• General — 16 A:
—Flameproof seal with cylindrical spigot joint.
—Automatic disconnection of the poles by patented dualsafety device, which ensures the following once the plug is
removed from the socket outlet:
– Automatic and simultaneous disconnection of each phase
in a flameproof chamber
– Disconnection, once power is off, of the pins in the second flameproof chamber
—Cover can be padlocked – 1 padlock diameter 5 mm (0.20
in), length 45 mm (1.77 in).
—Wall sockets and flush sockets incorporate a safety device
that only accepts plugging of ATX plugs which are certified
for use in hazardous areas.
—Plugs can be used with IEC 60309-2 compliant industrial pin
socket outlets in non-hazardous areas.
• General — 32 A:
—Flameproof seal with cylindrical spigot joint.
—Mechanical interlocking device ensures:
– Disconnection takes place within the flameproof chamber
before the plug is removed from the socket outlet
– The plug cannot be removed when energized
—Straight handle placed on the plug for use with IEC 603092 compliant industrial pin socket outlets in non-hazardous
areas.
• General — 80 A and 125 A:
—Interlocking mechanical device which prevents:
– The switch from closing until the plug is fully inserted into
the wall socket
– The plug from being removed until the switch is off
—Socket outlet supplied with a load break isolating switch
ensuring disconnection with power on.
—Switch handle can be padlocked in the “off” position (3
padlocks).
• Wall Sockets — 16 A:
—2 x M20 threaded cable entries (1 at the top, 1 at bottom).
—Supplied with one M20 plug.
—Connection on 2 x 4 mm2 (0.003 x 0.006 in2) terminals.
—Earth terminals: internal and external, with 4 mm diameter
screws.
• Wall Sockets — 32 A:
—2 x M25 threaded cable entries (1 at the top, 1 at bottom).
—Supplied with one M25 plug.
—Connection on 10 mm2 (0.016 in2) terminals.
—Earth terminals: internal and external with 6 mm diameter
screws.
• Wall Sockets — 80 A:
—1 x M32 threaded cable entry (on the top side).
—Connection via 8 mm (0.32 in) diameter lug terminals (not
supplied).
—Internal earth through 35 mm2 (0.054 in2) connection and
external earth through 0.24 in/6 mm diameter screws.
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
• Hazardous areas where plugs and sockets are used with
portable or stationary electrical equipment such as lighting and
heating systems, conveyors, motor starters, air-conditioning
appliances, compressors and pumps.
• Ideal for hazardous areas where weatherproof and robust
equipment is required.
• Ideal for hazardous areas Zones 1, 2, 21 and 22 in the oil and gas industry; such as refineries, pipelines and offshore sea-rigs.
PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets
Flameproof
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD or II 2 G
IP66 or IP55 – IK10
Plugs and Receptacles
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
ATEX/IECEx Certifications and Compliances
• Certification Type (16 A Plugs and Wall Sockets) PCX 16N
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIC
– T-Rating: T6 for Ta ≤ +40 °C (+104 °F); T5 for +40 °C ≤ Ta ≤
55 °C (+104 °F ≤ Ta ≤ +131 °F)
— Dust: Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081
II 2 D
– ATEX/IEC Protection: Ex tD A21
– Surface Temperature: T95 °C (T203 °F)
— Service Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
— CE Declaration of Conformity: 50243
— ATEX Certificate: LCIE 02 ATEX 6234
— IEC Certificate: LCIE Ex 02.030
• Certification Type (16 A Plugs and Flush Sockets) PCXd/EN
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIC
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081 II2 D
– ATEX/IEC Protection: Ex tD A21
— Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
— CE Declaration of Conformity: 5C227
— ATEX Certificate: LCIE 03 ATEX 0022U
— IECEx Certificate: LCIE Ex 03.029U
• Certification Type (32 A Plugs and Wall Sockets) PCX 32d
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d II
– T-Rating: T6 for Ta ≤ +40 °C (+104 °F); T5 for +40 °C ≤ Ta ≤
55 °C (+104 °F ≤ Ta ≤ +131 °F)
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: CE 0081 II2 D
– ATEX/IEC Protection: Ex tD A21
– Surface Temperature: T80 °C to T95 °C (T176 °F to T203 °F)
— Ambient Temperature: -40 °C to 55 °C (-40 °F to 131 °F)
— CE Declaration of Conformity: 50258
— ATEX Certificate: LCIE 02 ATEX 6134X
— IECEx Certificate: IECEx LCI 03.021X
1390
• Certification Type (80 A Plugs and Wall Sockets) PCX 80d
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIB
– T-Rating: T6 for Ta ≤ +40 °C (+104 °F); T5 for +40 °C ≤ Ta ≤
55 °C (+104 °F ≤ Ta ≤ +131 °F)
— Ambient Temperature: -40 °C to 55 °C (-40 °F to 131 °F)
— CE Declaration of Conformity: 50262
— ATEX Certificate: LCIE 03 ATEX 6149X
— IEC Certificate: LCI Ex 03.024X
— Internal Volume: < 2 dm3 (122 in3) (2 liters)
• Certification Type (125 A Plugs and Wall Sockets) PCX 125d
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: CE 0081
II 2 G
– ATEX/IEC Protection: Ex d IIB
– T-Rating: T5
— Ambient Temperature: -40 °C to 55 °C (-40 °F to 131 °F)
— CE Declaration of Conformity: 50263
— ATEX Certificate: LCIE 03 ATEX 6148X
— IEC Certificate: LCI Ex 03.023X
— Internal Volume: < 2 dm3 (122 in3) (2 liters)
• Other Cetifications: GOST
• Ingress Protection (solid and liquid): IP66
• Impact Resistance (shock): IK10
• 10 and 32 Amp:
— Ex Standards: EN / IEC 60079-0; 60079-1; 61241-0; 61241-1
— Product Standards: EN / IEC 60309-1; 60309-2
— Other Standards: EN / IEC 60529 (IP); 62262 (IK)
• 80 and 125 Amp:
— Ex Standards: EN / IEC 60079-0; 60079-1
— Product Standards: EN / IEC 60309-1; 60309-2
— Other Standards: EN / IEC 60529 (IP); 62262 (IK)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets
Flameproof
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD or II 2 G
IP66 or IP55 – IK10
Equipment
Pin Configuration
Weight kg (lb)
Volume dm3 (in3)
Catalog Number
1.7 (3.75)
5 (305)
PRD316RP
0.5 (1.10)
4 (244)
PRD316PP
1.7 (3.75)
5 (305)
PRD316RY
0.5 (1.10)
4 (244)
PRD316PY
1.7 (3.75)
5 (305)
PRD316RB
0.5 (1.10)
4 (244)
PRD316PB
1.8 (3.97)
5 (305)
PRD416RR
0.5 (1.10)
4 (244)
PRD416PR
1.9 (4.19)
5 (305)
PRD516RR
0.5 (1.10)
4 (244)
PRD516PR
10.4 (22.93)
17 (1037)
PRD432RR
1.5 (3.31)
4 (244)
PRD432PR
44.6 (98.33)
69 (4211)
PRD480RR
3.4 (7.50)
6 (366)
PRD480PR
47 (103.62)
69 (4211)
PRD412RR
5.9 (13.01)
7 (427)
PRD412PR
Extra Low Voltage
16 A – 20/25 Vac 50/60 Hz — Purple
Wall Socket
2P + E
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
Key Way
Plug
Low Voltage
16 A – 100/130 Vac 50/60 Hz — Yellow
Wall Socket
Plug
L/+
Key Way
2P + E
16 A – 200/250 Vac 50/60 Hz — Blue
Wall Socket
L/+
Key Way
Plug
2P + E
16 A – 380/415 Vac 50/60 Hz — Red
L2
Wall Socket
Plug
Wall Socket
L1
3P + E
L3
L2
L1
Key Way
N
3P + N + E 
Plugs and Receptacles
Plug
L3
Key Way
32 A – 380/415 Vac 50/60 Hz — Red
L2
Wall Socket
Plug
L1
L3
Key Way
3P + E
80 A – 380/415 Vac 50/60 Hz — Red
L2
Wall Socket
Plug
L1
L3
Key Way
3P + E
125 A – 380/415 Vac 50/60 Hz — Red
L2
Wall Socket
Plug
L1
L3
Key Way
3P + E
 200/346 V – 240/415 Vac 50/60 Hz.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
1391
PRD Series 16, 32, 80 and 125 Amp Plugs and Sockets
Flameproof
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD or II 2 G
IP66 or IP55 – IK10
Gas Group
Pin Configuration
Weight kg (lb)
Volume dm3 (in3)
Catalog Number
1.7 (3.75)
5 (305)
PRD316FPC
1.5 (3.31)
5 (305)
PRD316FPB
1.7 (3.75)
5 (305)
PRD316FYC
1.5 (3.31)
5 (305)
PRD316FYB
1.7 (3.75)
5 (305)
PRD316FBC
1.7 (3.75)
5 (305)
PRD316FBB
1.8 (3.97)
5 (305)
PRD416FRC
1.6 (3.53)
5 (305)
PRD416FRB
1.9 (4.19)
5 (305)
PRD516FRC
1.7 (3.75)
5 (305)
PRD516FRB
9.5 (20.94)
17 (1037)
PRD432FRC
9.2 (10.28)
17 (1037)
PRD432FRB
Flush Sockets for Mounting on Ex d IIB or Ex d IIC Enclosures
16 A – 20/25 Vac 50/60 Hz — Purple
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
Ex d IIC
2P + E
16 A – 100/130 Vac 50/60 Hz — Yellow
Ex d IIC
Ex d IIB
L/+
Key Way
2P + E
16 A – 200/250 Vac 50/60 Hz — Blue
Ex d IIC
L/+
Key Way
Ex d IIB
2P + E
16 A – 380/415 Vac 50/60 Hz — Red
L2
Ex d IIC
Ex d IIB
Ex d IIC
Ex d IIB
Plugs and Receptacles
Key Way
Ex d IIB
L3
Key Way
L1
3P + E
L3
L2
L1
Key Way
N
3P + N + E 
32 A – 380/415 Vac 50/60 Hz — Red
L2
Ex d IIC
Ex d IIB
L1
L3
Key Way
3P + E
 200/346 V – 240/415 Vac 50/60 Hz.
1392
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
PRD Series 16, 32, 80 and 125 Amp Plug and Socket Dimensions
Flameproof
16 Amp Plug and Wall Socket Dimensions in Millimeters (Inches)
110 mm (4.33”)
6.10/155
260 mm (10.24”)
9 mm (0.35”)
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
66 mm
(2.60”)
A
96 mm
(3.78”)
A
10 mm
(0.39”)
2P+E
70 (2.76)
3P+E
78 (3.07)
3P+N+E
85 (3.35)
175 mm (6.89”)
32 Amp Plug and Wall Socket Dimensions in Millimeters (Inches)
230 mm (9.06”)
225 mm (8.86”)
10 mm
(0.39”)
185 mm (7.28”)
95 mm
(3.74”)
15 mm
(0.59”)
fl
67 mm (3.74”)
120 mm (4.72”)
75 mm
(2.95”)
fl 7mm
(0.28”)
140 mm (5.51”)
Plugs and Receptacles
80 and 125 Amp Plug and Wall Socket Dimensions in Millimeters (Inches)
250 mm (10.04”_)
290 mm (11.42”)
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
123 mm (4.84”) (125 A)
101 mm (3.98”) (80 A)
650 mm (25.59”) (125 A)
30 mm
(1.18”)
550 mm (21.65”) (80 A)
226 mm (8.90”)
Ø 11 mm
(0.43”)
256 mm (10.08”)
276 mm (10.87”) (125 A)
235 mm (9.25”) (80 A)
1393
PRD Series 16, 32, 80 and 125 Amp Plug and Socket Dimensions
Flameproof
16 and 32 Amp Flush Socket Dimensions in Millimeters (Inches)
32 A - Ex d IIB
125 mm (4.92”)
96 mm (3.78”)
56 mm (2.20”)
60 mm (2.36”)
4 x M4
screws
91 mm (3.58”)
60 mm
(2.36”)
96 mm (3.78”)
135 mm (5.31”)
139 mm (5.47”)
ATEX/IECEx Flameproof Ex d Zone 1 Rated Plugs and Receptacles
16 A - Ex d IIB
4 x M4
screws
66 mm (2.60”)
16 A - Ex d IIC
32 A - Ex d IIC
Plugs and Receptacles
108 mm (4.25”)
78 mm (3.07”)
Ø 166 mm (6.54”)
150 mm (5.91”)
1394
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© February 2015
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising