KitchenAid 30" and 36" Retractable Downdraft Vent Systems User's Manual

HOME APPLIANCES Use 81Care Information Part No. 4324054/4360199 30” and 36” Retractable Downdraft Vent Systems IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for local electrical inspector’s use. \ Rev. E LUUII I~I UII I I~I m,n, curour ,,4” -:- -..1-... manufacturer’s instructions for Cutout width: 30” vent - 2J- 112” 36” vent - 33-112” A = cabinet wall to rear line of cutout Allow l/2” from rear of downdraft vent to back wall of cabinet. cooktop cutout depth and width. C5/8” 2-518” --.. \ countertop fl 8-114” retractable vent height Left cabinet wall cutout: ‘, I” 1J-i/16” II Cabinet centerline II I NOTE: Vent cutout shown assumes rear edge of cooktop overlaps edge of downdraft vent by 3/W. I Use dimensions for ductwork cutout location that applies to your installation. I 30” vent base width 36” vent base width - 27” 33” ‘: Locate supply box at corner Exterior-mounted Retractable downdraft .vent dimensions See cooktop Isions Cutout width: 3@” wnnt 37-4 13” 3E 1 C See cooktop manufacturer’s instructions for cooktop cutout depth and width. Allow 112” min. from rear of downdraft vent IA back b8s.r wall of to cabinet. motor: 26-118” power junction lower right of cabinet. Interior-mounted motor b F 9” round hole can be cut in floor, or right or left side of cabinet. I 9” round hole. Height can vary as needed. 1-l I I 9” round hois. Hsioht I -------- Ii Use dimensions %-l/4” retractable vent height for 30”;ent base width 36” vent base width - location that applies to your installation. 27” 33” Locate power supply junction box at lower right corner of cabinet. NOTE: Vent cutout shown assumes rear edge of cooktop overlaps edge of downdraft vent by 318”. 8” cutout 8” dimensions Exterior-mounted Figure 2 Figure 1 Dimension A: If just a “Max.” dimension given, that dimension must be used. is Example: “A Max.” Actual “A” *If dimension A is between the “Min.” and “Max.“: Subtract actual dimension “A” from “A Max.” Divide by 2. Models KIRD801 KIRD802 KIRD861 I When installed + with ( Figure see ( size ( Gn. ( Mtx. / B 9/l 6” 518” l-3116” = Required C dimension / :$L~zo~:.( x ( KECSlOP, KGCTlOO’ KECT305*, KGCT305* KECC500, KECC502, KECC507 KECN507 2 30” 18-314" 20-5/8" 1 30” c.‘.‘.:.:.~~~~:i:i:i:i:~ i~~~~~~~~~ 27- 1,2 II2” j::‘:‘::.. ~~~~~~ 20-l p ..-.i-:.;-,-:: ..... y.:.::::.:::.:.:.:.:.:::::::::::’ -~-~i~-~iis’iiii~~ii .,...__ i:~:~;~~:~:~:~:::::::::::~:::~ .:~~:~:~:~~~:~:~:~:~:iiI:I:I::: ...__.... :::::... ...... 1 KECG260'.KGCG260* 2 30” 36” 19-l/4" 18-314" 20-518" IKIRD862 1KECT365’. KGCT365’ 1 KECN560,‘KECN567 KECC560, KECC567 1 1 Panel A 20-518” - 19-318” 1-l/4” + 2 = 518” C (for A Max.) Add to “C (for A Max.)” for required C dimension. I KECSl 00, 1 g-3/8” cutout 1 1 36” 36” l-314" 2-l/8" l-314" 1 I I ~~~~I~I 19-l /4” 2- l/8” v :~~~~~~~~~~~ 20-l 12” l-1/2" l-112" g/16" 9116" 27-l/2" 27-l/2" 33-l/2" motor Before you start... Injury Hazard To eliminate the risk of burns or fire, avoid installing cabinet storage above the cooking surface. If cabinets are already installed, avoid the use of cabinets while cooktop is in use. Reaching over a heated cooking surface could result in a serious burn. Use two or more people to move and install downdraft vent. Failure to follow these instructions can result in back or other injury. Important: Observe all governing codes and ordinances. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the wiring box cover. Check location where downdraft vent will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Before making countertop cutout, check that downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet. ALL OPENINGS IN THE WALL OR FLOOR WHERE RETRACTABLE DOWNDRAFT VENT IS TO BE INSTALLED MUST BE SEALED. Electrical ground is required. See “Electrical requirements,” Panel B. When installing retractable downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet. 30” min. base cabinet is required. If cabinet has a drawer, 3-l/2” depth clearance from the countertop to the top of the drawer (or other obstruction in the base cabinet) is required. Note: Downdraft vent is installed directly behind the cooktop. Install downdraft vent first. Downdraft vent is not approved for use in mobile homes. Cabinet construction: Downdraft vent is designed for use in a cabinet with a depth of 24”. The maximum depth of the overhead cabinet is 13”. Overhead cabinets installed at either side of the downdraft vent must be 18” above the cooking surface. See cook-top Installation Instructions for the minimum distance between the front edge of the countertop and front edge of cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent. When installing a 36” retractable downdraft vent with three “Create-A-Cook-top” modules, the optional support must be installed on the front of the downdraft vent. See installation steps for details. L Electrical Shock Hazard Check for electrical wires that may be concealed behind wall covering before drilling holes into wall. Do not use downdraft vent solid state fan speed control device. Failure to follow these instructions could result in death, fire or electrical Lshock. It is the customer’s responsibility: To contact a qualified electrical installer. To assure that electrical installation is adequate and in conformance with National Electrical Code, ANSVNFPA 70 - latest edition*, and local codes and ordinances. Tools needed for installation: 8mm orpower 318” nut driver or ratchet supply cable Do Not ground to a gas pipe. Check with a qualified electrician if you are not sure the downdraft vent is properly grounded. Do Not have a fuse in the neutral or grounding circuit. IMPORTANT: Save Installation Instructions for electrical inspector’s use. IA.I A 120.volt, 60.Hz, AC-only electrical supply is required on a separate 15ampere circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of the downdraft vent as specified on the model/serial rating plate located on the front of the downdraft vent above the wiring box cover. le( THE RETRACTABLE DOWNDRAFT VENT MUST BE CONNECTED WITH COPPER WIRE ONLY n Ic . Wire sizes must conform to the requirements of the National Electrical Code, ANSIINFPA 70 - latest edition*, and all local codes and ordinances. Wire size and connections must conform with the rating of the downdraft vent. Copies of the standard listed above may be obtained from: sabe * National Fire Protection Batterymarch Park Quincy, Massachusetts mIm.-YIaYI Phillips y screwdriver screwdriv _. Association 02269 (DI This downdraft vent should be . connected directly to the fused disconnect (or circuit breaker) through flexible, armored or non-metallic sheathed, copper cable. Allow some slack in the cable so the downdraft vent can be moved if servicing is ever necessary. IEl ~ A U.L.-listed, l/2” conduit connector must be provided at each end of the power supply cable (at the downdraft vent and at the junction box). ‘arts supplied ‘or installation: IFI A wiring diagram is located on the downdraft vent base above the wiring box cover. . Electrical l l l l l 2 end caps 2 lower support legs 2 overcounter mounting brackets 2 undercounter mounting brackets 1 bag of fasteners l l l l 1 metal cover 1 backdraft damper literature package optional support and two screws (36” models only) Parts needed for installation: l l l Panel B Electrical Shock Hazard Electrically ground downdraft vent. Failure to follow this instruction could result in death, fire or electrical shock. If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate. WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction. B. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. Fire Hazard Do Not obstruct the flow of combustion and ventilation air. Failure to follow this instruction could result in fire. Electrical requirements 2 conduit connectors 1 wall cap for interior-mounted ductwork motor connection 1. Cut a 1-l/2” hole in floor or side of cabinet for power supply wire. The hole cut for electrical wiring through a wood cabinet should be sanded until smooth. A grommet (Part No. 302797) must cover the hole cut for the electrical wiring through a metal cabinet. 2. Run flexible armored or nonmetallic sheathed copper cable from fused disconnect circuit breaker or junction box through the cabinet hole to the downdraft vent location. 3. See installation steps to connect power supply cable to downdraft vent. Venting requirements Built-in cabinet Recommended location 3-,,4” x ,o” to 6” = 4.5 ft. ....:.-;-. .........-. Fire Hazard Venting system MUST terminate to the outside. Do Not terminate the ductwork in an attic or other enclosed space. Do Not use 4-inch laundry-type wall caps. Do Not use plastic-type ductwork. Use Only Metal Ductwork. Failure to follow these instructions may result in a fire. Ductwork needed for installation is not supplied. Wall cap is Not provided with interiormounted motor. Determine which venting method to use. Ductwork can extend either through the wall or roof. The length of ductwork and number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do Not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking tape to seal the exterior wall or floor opening around cap. Do Not cut joist or stud. If ductwork cutout falls over a joist or stud, a supporting frame must be constructed. . Flexible metal ductwork is Not recommended. If it is used, calculate each foot of flexible ductwork as two feet of rigid metal ductwork. Flexible elbows count twice as much as standard elbows. NOTE: Make sure there is proper clearance within the wall or floor exhaust duct before making cutouts. l l I/ =II 3.114 x 10” to 6” 90” elbow = 5 ft. fittings 6” to 3-114” x IO” 90” elbow = 9 ft. iear vent Figure 5 90” elbow = 5 ft. Ductwork installed under a concrete slab using PVC sewer pipe. 6” to 3.114” x 10” = 1 ft. ................ 45” elbow = 2.5 ft. ..:.:.:.:.:. -.6” wall cap min. 28 in. open = 0 ft. 6” round metal duct 90” PVC sewer pipe elbow 6”round 90” PVC sewer pipe elbow Tig/htly pack gravel or sand completely around pipe. II Put on gloves and safety glasses. . Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton. Remove all shipping materials, tape and protective film from downdraft vent and blower box. Optional ductwork installed under a concrete slab into a window well. Do not vent a gas cooktop into a window well. transition 6” round PVC 6” round metal duct l l (2 . Attach one overcounter mounting bracket to each side of the downdraft vent with flange side out. l l Recommended standard 6” mii. Tightly back gravel or sand completely around pipe. 6” round PVC coupling pipe elbow Seal the s ace between the outside of wall cap inlet inside of BVC coupling with caulking metal. Maximum system Attach support legs to side of downdraft vent with two screws in each leg. Do Not tighten screws. length of ductwork duct length For either interior-mounted or exteriormounted blower installations, ductwork length should not exceed the maximum lengths listed in the “Maximum length of duct system” chart. (See Panel C for interior-mounted blower; Panel E for exterior-mounted blower.) Interior-mounted vent motor For best performance, use no more than three 90” elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches of straight duct between any two elbows. Do Not install two elbows together. It is recommended that you use round duct instead of rectangular duct, especially if elbows are required. If rectangular duct is required, it should be transitioned to 6” round duct as soon as possible. Determining you need: Island location the length of system To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 6” round ductwork system. wn vent Injury Hazard Use two or more people to move and install downdraft vent. Failure to follow this instruction can result in back or other injury. 6” round ductwork system I - I 14 . Carefully insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets overlap countertop. Figure 3 Built-in cabinet location Maximum length = 25 ft. 1 - wall cap 8 feet straight 2 - 90” elbows Transition = 0 = 8 = 10 = 4.5 Length of 6” system = 22.5 Figure 4 Panel C feet feet feet feet feet 15) Move support legs down against ’ cabinet floor. Place a level against front of downdraft vent base and adjust until downdraft vent is level vertically. Use a pencil to mark the top of each leg on face of downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs. If blower box is removed from vent base, check that wiring cable is properly secured in plastic clips. Determine which direction (down or rear) ductwork will need to run from blower duct when installed in cabinet. Down venting: Downdraft vent is shipped with blower in down venting position so no modification is required. Go to Step 7. Left or right venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Rotate blower box 90” to left or right so that vent blower is repositioned in the direction needed. c. Reattach blower box to downdraft vent base with 4 hex nuts. Rear venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Note how wiring cable is installed under plastic clips inside vent base. Then carefully remove wiring cable from plastic clips. Disconnect blower wiring cable. c. Remove 6 Phillips-head screws attaching blower to blower box. Remove blower. bracket Interior-mounted blower Numbers correspond to steps. Injury Hazard Use two or more people to move and install downdraft vent. Failure to follow this instruction can result in back or other injury. hnr knockouts Disconnect power supply. Thread the power supply cable through the knockout opening in the wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) grounding wire to eyelet with green grounding screw. Reattach the wiring box cover. for lg.1 d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws. e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws. NOTE: Square metal frame attached to mouth of blower must be installed for proper operation. f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base. g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base. Reattach blower box to downdraft vent base with 4 hex nuts. Insert downdraft vent into countertop cutout. Two people are recommended to support the weight bf the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws. Snap end caps over top of mounting brackets, microswitches /\ When attaching undercounter bracket to underside of countertop: Do Not drill into countertop surface. Check that mounting screws are proper length and will not go through countertop surface when tightened. Turn power supply on. Push the button on the top of the downdraft vent. Retractable section of downdraft vent will rise and blower will start. Turn the control knob on side of vent to check the operation and speed of blower. If blower does not operate: Check that filters are pressed in as far as they will go. Check that circuit breaker is not tripped or house fuse blown. Disconnect power source and check that wire connections have been made correctly l on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop. I ON/OFF , button l l 17.1 behind filters. Connect ductwork to blower. Position ductwork to avoid wall studs and floor joists. Complete all ductwork. Use duct tape to seal all joints. Ductwork must end with a wall or roof cap. Install cook-top according to manufacturer’s instructions. Check that rear edge of cook-top overlaps edge of downdraft vent by 3/8”. I Attach backdraft damper over blower box knockout with 2 Phillips-head screws. 1 8.1 Remove the 2 Phillips-head 1 screws attaching appliance wiring r box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Knock out rear or lower wiring opening in wiring box. Panel D To get the most efficient use of your new retractable downdraft vent, read Use & Care Information section on Panel G. Keep Installation Instructions and Use & Care Information close for easy reference. Exterior-mounted vent motor 9” round ductwork system Injury Hazard Use two or more people to move and install downdraft vent. Failure to follow this instruction can result in back or other injury. NOTE: Exterior-mounted vent motor installations require exterior blower system, Part No. KPED890T, available from your KitchenAid dealer or authorized parts supplier. Island location Maximum = = = = 1 - transition 2 - 90 elbows 1 - wall cap 10 feet straight 0 10 0 10 length = 55 feet feet feet feet feet Carefully insert downdraft vent into Length of 9” system = 20 feet Recommended cabinet fittings :::::::zy;::::::> i-.. -.:.:.:.:.: .-::::: .:.. ...:.:.:.. .. -+::o .:.... j::::::::::::::::: ::-. .:.-.. ..:j::::::: .:.-.-.A.. .,.,-.:.: .. .;.._ ::.. ,:;:~:.::~ :.:.: j:: ,.,.,.,.,.,. .:::::::::y. ‘7::.;+;;$;:;::z. L’ <;;$P= .._.,..Q Figure 6 Built-in standard recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets rest gently on countertop. location 3-114” x 14” to 9” = 4.5 ft. 3-l/4” x 14” to 9” 90” elbow = 5 ft. 9” to 3 1/4”xl4” 90” elbow = 9 ft. ..:.::::: . .-. -:.:.:.. -.: --$PT~90” elbow = 5 ft. Figure 7 II front of downdraft vent base and adjust position of legs until downdraft is level vertically. Use a pencil to mark the top of each leg on face of downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs. ’ 16.1 171 Attach damper plate (supplied with exterior blower svstem) to front of downdraft vent using 4 hex washer nuts. 12.1 L E 3-114” x 14” duct Figure 8 Maximum system 45” elbow = 2.5 ft. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton. Remove all shipping materials, tape and protective film from downdraft vent and blower box. Roof venting 1 9” to 3-114” x 14” = 1 ft. length of ductwork Remove the 2 Phillips-head screws attaching appliance wiring box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Remove cover. Knock out rear or lower wiring opening in wiring box. . 1 Attach one overcounter mounting bracket to each side of the downdraft vent with flange side out. Power supply cable needed between exterior blower assembly and blower box is not provided. , I b-l . Attach support legs to side of downdraft vent with two screws in each leg. Do Not tighten screws, Ductwork may be installed under concrete slab. See Panel C. Do not install exterior vent motor in window well. Is Determine the location where the ’ exterior blower box will be located. Cut opening in roof or wall for ductwork to exterior blower. Install exterior blower. Wall Installations Use caulking compound between mounting flange and wall. Roof Installations Follow standard roofing procedures. The flashing sheet should be entered over the roof opening. Lower edge of flashing should lie on top shingles and upper edge underneath shingles. Seal assembly between roof, fan and flashing with roofing mastic to prevent leaks. l For best performance, use no more than three 90” elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches of straight duct between any two elbows. Do Not install two elbows together. It is recommended that you use round duct instead of rectangular duct, especially if elbows are required. If rectangular duct is required, it should be transitioned to 9” round duct as soon as possible. Determining the length of system you need: To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 9” round ductwork system. Panel E l l l l Exterior-mounted blower Numbers correspond to steps. 6. into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is vertical. Then attach lower support legs to cabinet floor with screws. Snap end caps over top of mounting brackets When attaching undercounter bracket to underside of countertop: Do Not drill into countertop surface. Check that mounting screws are proper length and will not go through countertop surface when tightened In place. wiring w green grounding screw bOX cover Install cook-top according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by 3/W. D-l ‘wiring remote blower I mounting bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop. Disconnect power supply. Thread the power supplv cable through the knockout opening in the wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) grounding wire to eyelet with green grounding screw. Reattach the wiring box cover microswitches 11 behind filters. / \ ON/OFF , button . Turn power supply on. Push the button on the top of the downdraft vent. Retractable section of downdraft vent will rise and blower will start. Turn the control knob on side of vent to check the operation and speed of blower. If blower does not operate: l Check that filters are pressed in as far as they will go. l Check that circuit breaker is not tripped or house fuse blown. l Disconnect power source and check that wire connections have been made correctly. Panel F Connect ductwork to blower. Position ductwork to avoid wall studs and floor joists. Complete all ductwork. Use duct tape to seal all joints. Vertical ductwork for wall-mounted installations should pitch down slightly toward the vent to allow moisture to run outside. To get the most efficient use from your new retractable downdraft vent, read the Use and Care information section on Panel G. Keep Installation Instructions and Use and Care Information close by for easy reference. Use & Care Information The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cook-top area. For the best results, the vent should be operating before cooking is started. If you use large or tall utensils, place them on the large rear element or burner surface. A higher heat setting than normally used may be needed when the downdraft vent is operating. WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. WARNING -TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: A. Keep fan, filters and grease laden surfaces clean. B. Always turn hood ON when cooking at high heat. C. Use high range settings on range only when necessary. Heat oil slowly on low to medium setting. D. Don’t leave range unattended when cooking. E. Always use cookware and utensils appropriate for the type and amount of food being prepared. WARNING -TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: A. SMOTHER FLAMES with a closefitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN - You may be burned. C. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. D. Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. 4. You can fight the fire with your back to an exit. Panel G Operating downdraft vent - Push button on top of downdraft vent. Retractable section of downdraft vent will rise and blower will begin to vent. Turn knob on side of downdraft vent to adjust the setting to the amount of venting you need. The knob has infinite settings. Place cooking utensils on cooking surface and turn cooking unit on. When cooking is complete, turn cooking unit off, remove utensils from cooking surface, and push button on top of retractable downdraft vent. The blower will turn off and the retractable section of the vent will return to the closed position. Cleaning - Surface of downdraft vent: Clean with soap and water. Do Not use scouring powder or abrasive solutions. Filters: Frequently remove and clean the filters in the retractable section of the downdraft vent. This will improve the operating efficiency of the downdraft vent system. 1. Remove the filters and clean them in the dishwasher or in a hot detergent solution. Do Not use the downdraft vent when the filters are not in place. 2. Reinstall the clean filters, making sure that the filters are pushed in as far as they will go, Note: Downdraft vent will not operate if filters are not in proper position. If retractable downdraft vent does not operate after clean filters have been reinstalled: Push the filters in as far as they will go. When the filters are removed, the microswitches behind the filters are inactivated. This safety feature stops the blower and raising mechanism until the filters are properly reinstalled. microswitches left metal filter behind filters right mbtal filter If retractable downdraft vent does not operate... l l l l Check that filters are pressed in as far as they will go. Check that top corners of filter frame are pressed against microswitches located behind filter. Check that the circuit breaker is not tripped or the house fuse blown. Disconnect power source and check that wire connections have been made, If you need assistance... If you need service... The KitchenAid Consumer Assistance Center will answer any questions about operating or maintaining your retractable downdraft vent system not covered in the Installation Instructions. Call the KitchenAid Consumer Assistance Center toll-free telephone number: l-(800) 422-l 230. When you call, you will need the retractable downdraft vent system model number and serial number. Both numbers can be found on the model/serial rating plate located on the front of the downdraft vent above the wiring box cover. If you need further assistance, you can write to KitchenAid with any questions or concerns at: KitchenAid Brand Home Appliances Consumer Assistance Cent& c/o Correspondence Dept. 2000 North M-63 Benton Harbor, Ml 49022 Please include a daytime phone number in your correspondence. In the event that your KitchenAid retractable downdraft vent system should need service, call the dealer from whom you purchased the vent system or a KitchenAid-authorized service company. A KitchenAid-authorized service company is listed in the Yellow Pages of your telephone directory under “Appliances Household - Major - Service and Repair.” You can also obtain the service company’s name and telephone number by dialing, free, within the continental United States, the KitchenAid Consumer Assistance Center telephone number, l-(800) 422-l 230. A special operator will tell you the name and number of your nearest KitchenAid-authorized service company. Maintain the quality built into your KitchenAid appliance - call a KitchenAid-authorized service company. If the dealer, authorized servicer, and KitchenAid have failed to resolve your problem, you can contact the Major Appliance Consumer Action Program (MACAP). MACAP is a group of independent consumer experts that voices consumer views at the highest levels of the major appliance industry. MACAP will in turn inform us of your action. Major Appliance Consumer Action Program 20 North Wacker Drive Chicago, IL 60606 KitchenAid@ Downdraft Vent Warranty LENGTH OF WARRANTY: KITCHENAID One Year Full Warranty from date of installation. Replacement parts and repair labor to correct defects in materials or workmanship. Service must be provided by an authorized KitchenAid servicing outlet. Five Year Limited Warranty one year full plus second through fifth year limited from date of installation. Replacement motor if defective materials or workmanship. WILL PAY FOR: KITCHENAID in WILL NOT PAY FOR: A. Service calls to: 1. Correct the installation of the downdraft vent. 2. Instruct you how to use the downdraft vent. 3. Replace house fuses or correct house wiring. B. Repairs when downdraft vent is used in other than normal home use. C. Damage resulting from accident, alteration, misuse, abuse, improper installation or installation not in accordance with local electrical codes. D. Any labor costs during limited warranty. E. Replacement parts or repair labor costs for units operated outside the United States. F. Pickup and delivery. This product IS designed to be repaired in the home. KitchenAid, Inc. does not assume any responsibility for incidental or consequential damages. Some slates do nol allow the exclusion or limitation of incidenlal or consequential damages, so lhis exclusion or limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Part No. 4324054/4360199 Rev. E 0 1996 KitchenAid 8 Registered Trademark of KitchenAid, HOME APPLIANCES U.S.A. Prepared by KitchenAid, Benton Harbor, Michigan 49022
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement