KitchenAid 30" Electric Freestanding Range User's Manual

® HOME APPLIANCES 9758644 9758644 Installation Instructions 30" Electric Freestanding Range WARNING Quick Reference Table of Contents: Pages Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. 2 Before you start 3 Product dimensions 3 Cabinet dimensions/requirements 4 Electrical requirements 5 - 8 Check operation 10 If range does not operate 10 If you need assistance/service 10 Moving the range IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Read and save these instructions for local electrical inspector’s use. Installation steps 9 www.kitchenaid.com Write down the model and serial numbers before installing range. Both numbers are listed on the model/serial rating plate located on the oven frame behind the storage drawer panel. Model # _______________________________ Serial # _______________________________ 1 Part No. 9758644 Before you start... Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: DANGER You can be killed or seriously injured if you don't immediately follow instructions. WARNING You can be killed or seriously injured if you don't follow instructions. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. IMPORTANT: Observe all governing codes and ordinances. Failure to meet codes and ordinances could lead to fire or electrical shock. Proper installation is your responsibility. A qualified technician must install this range. Make sure you have everything necessary for correct installation. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the oven frame behind the storage drawer panel. Check location where range will be installed. The range should be located for convenient use in kitchen. To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets. All openings in the wall or floor where ranges is to be installed must be sealed. Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances. Grounded electrical outlet is required. See “Electrical requirements” section. 2 Mobile home installation The installation of this range must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A*, or with local codes. When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above. Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be revised. See “Four-wire electrical connection” section. Tools needed: Follow all factory safety instructions included with your tools. • level • flat-blade screwdriver • 3/8" drive ratchet • 3/8" and 5/16" nut drivers • hand or electric drill • channel lock pliers • safety glasses • gloves • measuring tape or ruler • wood floors: 1/8" drill bit • concrete/ceramic floors: 3/16" carbide-tipped masonry drill bit (Hammer may be needed for anchors.) Parts supplied: The floor anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see Page 5 and the anti-tip bracket template. Copies of the standards listed may be obtained from: * National Fire Protection Association One Batterymarch Park Quincy, Massachusetts, 02269 Not shown: literature pack 2 plastic anchors 2 screws (#10 x 1-1/2") floor-mounted anti-tip bracket Brackets must be securely mounted to sub-floor. Thickness of flooring may require longer screws to anchor bracket to sub-floor. Longer screws are available from your local hardware store. Product dimensions 46-13/16" (119.0 cm) overall height 26-3/8" (67 cm) depth with handle 36" (91.4 cm) cooktop height 30" (76.2 cm) width 24-1/2" (62.2 cm) Cabinet dimensions/requirements Cabinet opening dimensions shown are for: 25" (63.5 cm) countertop depth, 24" (61.0 cm) base cabinet depth, 36" (91.4 cm) countertop height 13" (33 cm) max. upper cabinet depth For minimum clearance to the top of the cooktop, see NOTE.* 30" (76.2 cm) min. cabinet opening width 18" (45.7 cm) upper side cabinet to countertop 30-3/8" (77.2 cm) opening width *NOTE: 24" (61 cm) min. when bottom of wood or metal cabinet is protected by not less than 1/4" (6.4 mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet. 4" (10.2 cm) min. clearance from both sides of range to side wall or other combustible material above the countertop. wall receptacle or junction box – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 7" (17.8 cm) max. from floor. 7/8" (2.2 cm) min. required between cutout and cabinet door or hinge. 3 Electrical requirements If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path and wire gauge are in accordance with local codes. This range must be connected to a grounded metal, permanent wiring system. Check with a qualified electrician if you are not sure range is properly grounded. Do not ground to a gas pipe. Do not have a fuse in the neutral or ground circuit. Range must be connected to the proper electrical voltage and frequency as specified on the model/serial rating plate. (The model/serial rating plate is located on the oven frame behind the storage drawer panel.) A four-wire or three-wire, singlephase, 120/240-volt, 60-Hz, AC-only, electrical supply (or three-wire or fourwire 120/208-volt if specified on the model/serial rating plate) is required on a separate, 40 amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible armored conduit. This range can be direct wired to a fourwire or three-wire aluminum wiring system. See “Direct wire method: Copper or Aluminum wire” section. Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary. A U.L.-listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box). Wire sizes and connections must conform with the rating of the range (40 amps). The wiring diagram is located on the back of the range or on the inside of the storage drawer in a clear plastic bag. Recommended ground method It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and is in conformance with the National Electrical Code, ANSI/NFPA 70 — latest edition* and all local codes and ordinances. Power supply cord is not supplied, but is available through your local electrical supply house. If connecting to a four-wire system: This range is manufactured with the ground connected to the cabinet. The ground must be revised so the green grounding wire of the four-wire power supply cord is connected to the cabinet. See “Four-wire electrical connection” section. When a four-wire receptacle of NEMA Type 14-50R is used (see Figure 1, below), a matching U.L.-listed, four-wire, 250-volt, 40 amp, range power supply cord (pigtail) must be used. This cord contains four copper conductors with either ring terminals or spade terminals with upturned ends to connect the power supply at the appliance end, terminating in a NEMA Type 14-50P plug on the supply end. The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a U.L.-listed strain relief and be at least four feet long. The minimum conductor sizes for the copper four-wire power cord are: 40 amp circuit 2 No.-8 conductors 1 No.-10 white neutral 1 No.-8 green grounding If connecting to a three-wire system: Copies of the standards listed may be obtained from: *National Fire Protection Association One Batterymarch Park Quincy, Massachusetts, 02269 Local codes may permit the use of a U.L.-listed, 250-volt, 40 amp range power supply cord (pigtail). This cord contains three, No.-10 copper wires and matches a three-wire receptacle of NEMA Type 10-50R, shown in Figure 2. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. 4-wire wall receptacle (14-50R) Figure 1 4 3-wire wall receptacle (10-50R) Figure 2 Now start... WARNING WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Remove shipping materials, tape and protective film from range. Keep cardboard bottom and shipping base under range. Remove oven racks and parts package from inside oven. 2. Take four cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with other two corners. Place them lengthwise on the floor behind the range — to support the range when it is laid on its back. 3. Firmly grasp the range and gently lay it on its back on the cardboard corners. 4. 5. Pull cardboard shipping base firmly to remove. Use an adjustable wrench to loosen the leveling legs four complete turns. Electrical connection 8. Remove the terminal block cover located on the back of range. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type floor covering. 7. Use the anti-tip bracket template to install the anti-tip bracket. Anti-tip bracket must be anchored securely to the sub-floor. terminal block cover 9. Depending on your electrical supply, make the four-wire or three-wire connection to the range following the “Power supply cord method” or “Direct wire method” instructions for copper wire or aluminum wire depending on the connection needed. knockout opening for 40 amp power supply cord knockout opening for power supply cable Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the sub-floor. Longer screws are available from your local hardware store. Check that range is on cardboard shipping base to protect floor covering. 6. Place cardboard or hardboard in front of range. Stand range back up onto cardboard or hardboard. 5 Power supply cord method: NOTE: The bag containing three aluminum terminal lugs is not used when connecting the range using a power supply cord. WARNING 5. Use either ring-type terminals or spade terminals with upturned ends to connect the power supply. 10. Connect the neutral wire (center wire) to the center terminal screw on the terminal block. See Figure 2. 6. Complete electrical connection according to your type electrical supply (“Four-wire electrical connection” or “Three-wire electrical connection.”) 11. Connect the other two wires (lines 1 and 2) to the outer screws on the terminal block. See Figure 2. Four-wire electrical connection: 12. Securely tighten nuts with 3/8" nut driver for proper electrical connection. 13. Tighten the strain relief screws. 14. Replace the terminal block cover. 15. Plug power supply cord into grounded electrical outlet. Electrical Shock Hazard Disconnect power before servicing. Use new 40 amp power supply cord. Plug into grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. ground link Three-wire electrical connection: ground-link screw center terminal block screw Figure1 WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. This range is manufactured with the neutral terminal connected to the cabinet. Use a three-wire, U.L.-listed, 40 amp power supply cord (pigtail); or if local codes Do not permit ground through the neutral, use a four-wire power supply cord rated at 250 volts, 40 amps and investigated for use with ranges. (See “Four-wire electrical connection.”) neutral wire (center wire) center terminal block screw ground link line 1 line 1 U.L.-listed strain relief and 40 amp range power supply cord ground-link screw green ground wire line 2 U.L. listed strain relief and 40 amp range power supply cord Figure 2 Use this method for new installations, mobile homes, recreational vehicles and whenever four-wire installation is required. 7. remove knockout for 40 amp power cord and U.L. listed strain relief 1. Disconnect power. 2. Remove the knockout for the 40 amp power supply cord. 3. Assemble a U.L.-listed strain relief in the opening. 4. Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal block. 6 line 2 ground link Figure 3 Use this method only if local codes permit connecting cabinet-ground conductor to neutral wire of power supply cord. 7. opening for conduit connector neutral (center wire) Remove the ground-link screw from the range frame. Save the ground-link screw. Bend up the ground link so that it does not contact the range. See Figure 1. 8. Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must be attached first and must not contact any other terminal. See Figure 2. 9. Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factorytightened nuts behind the outside nuts. Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factorytightened nuts behind the outside nuts. 8. Connect the neutral wire (center wire) to the center terminal screw on the terminal block. See Figure 3. 9. Connect the other two wires (lines 1 and 2) to outer terminal screws on the terminal block. See Figure 3. 10. Securely tighten nuts with 3/8" nut driver for proper electrical connection. 11. Tighten the strain relief screws. 12. Replace the terminal block cover. 13. Plug power supply cord into grounded electrical outlet. Direct wire method: Copper or Aluminum wire NOTE: The bag containing three aluminum terminal lugs must be used when making a direct wire connection. WARNING 7. IMPORTANT: the aluminum terminal lugs must be assembled to the terminal posts with the set screws facing out as shown. 8. Attach three aluminum terminal lugs to terminal posts. Use a 3/8" nut driver and tighten the nuts securely. Nuts must be tightened to 20 in/lbs of torque for proper electrical connection. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper wire, or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. 9. Complete electrical connection according to your type electrical supply (“Four-wire electrical connection” or “Three-wire electrical connection.”) Four-wire electrical connection: slotted set screw neutral (center wire) line 1 green ground wire line 2 Figure 2 3" Use this method for new installations, mobile homes, recreational vehicles and whenever four-wire installation is required. 6. Use 3/8" nut driver and remove the outside nuts on the terminal block screws. Do not loosen the factorytightened nuts behind the outside nuts. aluminum lug slotted set screw neutral (center wire) line 2 U.L.-listed conduit connector 5. Allow enough slack in the wire to easily attach the wiring terminal block. 16. Replace the terminal block cover. line 1 2. Remove the knockout as needed for conduit connection. 1" 15. Tighten the locking ring of the conduit connector. ground screw Figure 1 4. Strip outer covering back 3 inches to expose wires. Strip the insulation back 1 inch from the end of each wire. 14. Securely tighten the set screws. For 8 gauge copper wire, tighten to 25 in/lbs of torque, and for 6 gauge aluminum wire, tighten to 35 in/lbs of torque to make a proper electrical connection. See Figure 2. ground link Disconnect power. 3. Assemble a U.L.-listed conduit connector in opening. 13. Connect the other two wires (lines 1 and 2) to the outer aluminum lugs. Three-wire electrical connection: This range may be connected directly to the fuse disconnect or circuit breaker box; or with a U.L.-listed, 40 amp range power supply cable. Depending on your electrical supply, make the required three-wire or four-wire connection. 1. 12. Loosen (do not remove) the 3 slotted set screws. Insert the neutral (white) wire into the hole at the bottom of the center position lug (attached to center terminal screw black terminal block). See Figure 2. 10. Remove the ground-link screw from the range frame. Save the ground-link screw and cup washer. Bend up the ground link so that it does not contact the range. See Figures 1 and 2. 11. Connect the green ground wire to the range using the ground-link screw and cup washer. The ground wire must be attached first and must not contact any other terminal. See Figure 2. Figure 3 Use this method only if local codes permit connecting ground conductor to neutral supply wire. 10. Loosen (do not remove) the 3 slotted set screws. Insert the neutral (white) wire into the hole at the bottom of the center position lug (attached to center terminal screw of terminal block). See Figure 3. 11. Connect the other two wires (lines 1 and 2) to the outer aluminum lugs. 12. Securely tighten the set screws. For 8 gauge copper wire, tighten to 25 in/lbs of torque, and for 6 gauge aluminum wire, tighten to 35 in/lbs of torque to make a proper electrical connection. See Figure 3. 13. Tighten the locking ring of the conduit connector. 14. Replace the terminal block cover. terminal screw set screw must face out 7 Operating position 9. 10. Move range close to cabinet opening. Remove cardboard or hardboard from under range. Carefully move range into final position. 12. Make sure the anti-tip bracket is installed: • Look for the anti-tip bracket securely attached to floor. 14. Place rack in oven. Place level on rack, first side to side; then front to back. • Slide range back so rear range foot is under anti-tip bracket. 11. Pull drawer open to first stop position. Lift front of drawer to clear white wheels in drawer guides. Remove drawer and set it aside on a protected surface. anti-tip bracket range foot 13. If installing the range in a mobile home, you must secure the range to the floor. Any method of securing the range is adequate as long as it conforms to the standards in the “Mobile home installation”section. If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket. Use 3/8" drive ratchet and channel lock pliers to adjust leveling legs up or down until range is level. Push range back into position. Check that rear leveling leg is engaged in anti-tip bracket. NOTE: Oven must be level for satisfactory baking conditions. 15. 16. Replace the storage drawer or lower panel. 8 Reconnect power. Check operation 17. Check the operation of the cooktop elements: Push in and turn each surface unit control knob to “HI” position. Check the operation of the cooktop elements and indicator lights. LO OFF 18. Check the operation of the oven: Press the “CLOCK SET” button. “TIME, HR AND MIN” will light up in the display. “0:00” will appear and the “:” will be flashing. Press the number buttons for the correct time of day. Press “START/ENTER” button to start the clock. HI 888° DELAY CLEAN DEHYD D ME START? ON 88:88° HR MIN MIN SEC LO MED Press “CANCEL/OFF” button. 19. Check the operation of the broil element. Press the “BROIL” button. “500°” will appear in the temperature display. The ON, Inner and Outer Broil Elements and Oven Cavity symbols will light up in the display. Press the “START/ENTER” button. CLEAN START STOP TIMER M ED HI TIMED LOCKED ROTIS The bottom element should glow red and the indicator light should be on. The upper element should become hot but not glow red. The oven indicator light goes off when the oven is preheated. Check the operation of the oven element. Press the “BAKE” button. “350°” will appear in the temperature display. The ON, Bake Element, Outer Broil Element and Oven Cavity symbols will light up in the display. Press the “START/ENTER” button. The top element should glow red and the indicator light should be on. Press the “CANCEL/OFF” button. You have just finished installing your new range. To get the most efficient use from your range, read your Use & Care Guide. Keep Installation Instructions and Guide close to range for easy reference. The instructions will make installing the range in another home as easy as the first installation. 9 If range does not operate: Check that the circuit breaker is not tripped or the house fuse blown. Check that the power supply cord is If you need assistance: If you need service: If you have questions about operating, cleaning or maintaining your range: In the event that your KitchenAid appliance should need service, call the dealer from whom you purchased the appliance or a KitchenAid-authorized service company. A KitchenAidauthorized service company is listed in the Yellow Pages of your telephone directory under “Appliances – Household – Major – Service & Repair.“ You can also obtain the service company’s name and number by dialing, free within the continental United States, the KitchenAid Customer Interaction Center telephone number, 1-800-422-1230. A special operator will tell you the name of your nearest KitchenAid-authorized service company. Refer to Use and Care Guide. The KitchenAid Customer Interaction Center will answer any questions about operating or maintaining your range not covered in the Installation Instructions. The KitchenAid Customer Interaction Center is open 24 hours a day, 7 days a week. Just dial 1-800-422-1230 – the call is free within the continental United States. plugged into the outlet. See Use and Care Guide for troubleshooting list. When you call, you will need the range model number and serial number. Both numbers can be found on the model/serial rating plate located on the oven frame behind the door. Maintain the quality built into your KitchenAid appliance — call a KitchenAid-authorized service company. Moving the range WARNING When moving range, slide range onto cardboard or hardboard to prevent damaging the floor covering. If removing the range is necessary for cleaning or maintenance: 1. Unplug range or disconnect power. 2. Slide range forward to complete cleaning or maintenance. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. 10 anti-tip bracket 3. Make sure the anti-tip bracket is installed: • Look for the anti-tip bracket securely attached to floor. • Slide range back so rear range foot is under anti-tip bracket. range foot 4. Check that range is level. 5. Plug in range or reconnect power. Notes 11 HOME APPLIANCES Part No. 9758644 © 2004 KitchenAid 12Registered Trademark of KitchenAid. ® Prepared by KitchenAid, Benton Harbor, Michigan 49022 Printed in U.S.A. 01/2004
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement