KitchenAid KUIC18NNT User's Manual

® Ice Maker PRODUCT DIMENSIONS PRODUCT MODEL NUMBERS KUIA18NNJ KUIA18PNL KUIC18NNT KUIS18NNT KUIC18PNT KUIS18PNT 33 ¹³⁄₁₆" (85.9 cm) Min. Electrical: 115 volt, 60 Hz, AC only, 15 or 20 amp grounded circuit is required. A time-delay fuse or circuit breaker and separate circuit is recommended. Water: A cold water supply with water pressure of between 30 and 120 psi (207 and 827kPa) is required to properly operate the ice maker. Drain: Either a gravity drain system or a drain pump system to carry water to an existing drain. 34 ⁵⁄₁₆" (87.1 cm) Max. with leveling legs fully extended CABINET OPENING DIMENSIONS 17 ¹³⁄₁₆" (45.2 cm) A. Recommended location for electrical and plumbing fixtures. 25 ⁵⁄₈" (65.1 cm) B. Floor level 14¹⁄₂ " (36.8 cm) 34" (86.4 cm) Min. 34¹⁄₂ " (87.6 cm) Max. A 28¹⁄₂ " (72.4 cm) 3¹⁄₂ " 9" (8.9 cm) (22.9 cm) B 24" (60.1 cm) 23 ¹⁄₈" (58.7 cm) 18" (45.7 cm) DRAIN REQUIREMENTS REAR VIEW SIDE VIEW A B C 1⁷⁄₈" (1.9 cm) 1" (2.5 cm) A. Drain hose (drain pump models only) B. Vent hose (drain pump models only) C. Water supply line 20" (50.80 cm) Drain lines must have a minimum of 5⁄8" (15.88 mm) inside diameter. Drain lines must have a 1" drop per 48" (2.54 cm drop per 122 cm) of run or 1⁄4" drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle. The floor drains must be large enough to accommodate drainage from all drains. The ideal installation has a standpipe with a 1-1⁄2" (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed A directly below the outlet of the drain tube as shown. B You must maintain a 1" (2.54 cm) air gap between the drain hose and the standpipe. It may be desirable to insulate the drain line C thoroughly up to the drain inlet. 2" - 1¹⁄₂" (5 cm - 3.8 cm) D Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. A. Drain hose B. 1" (2.54 cm) air gap C. PVC drain reducer D. Center of drain should be 20" (50.8 cm) from front of door, with or without the ³⁄₄" (1.91 cm) panel on the door. The drain should also be centered from left to right (8 ¹³⁄₁₆" from either side of the ice maker). Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. 2313820A 05-04-07
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement