Modular Special Hazard Safety Controls SYSTEM CONCEPT The Allestec 800 series gas and fire control panel is designed to supervise and respond to the result of a gas or fire signal while maintaining simple panel annunciation. This modular system is primarily suited for the end user who requires a minimum learning curve and simplicity in installation as well as operation. One panel assembly is designed to accommodate small to medium requirements. As many as 32 points of initiating devices can accommodate a panel assembly. Field wiring is completed on a point to point installation between devices and the panel. A remote abort is possible with the optional digital Abort Panel. Completely occupied, the entire panel dimensions are only 3.5" high X 19" wide X 7" deep. SELECTABLE MODULES Task specific modules perform functions related to their respective input detectors or output appliances. The modules can be selected to accommodate the best possible configuration while allowing room for expansion as necessary. Removal of any module from the slot will induce a system fault. GAS / FIRE SYSTEM INTEGRATION IN A SINGLE ENCLOSURE EIA standard 19" width panel Integrates gas and fire control in same enclosure Designed for special hazard industrial environments Conforms to all NFPA standards for signaling and releasing Abort module available to hold-delay or restart discharge Release module is able to activate a reserve tank if the first tank fails, or fire remains after first tank is released Fully automatic operation Inhibit to invoke a system test 24VDC input can use customer redundant power rail Voting capabilities Time delay for single spectrum detectors Low power CMOS and microcomputer design Three year parts and labor warranty APPLICATIONS SYSTEM EVENTS Oil refineries All faults are displayed at the lower half of the modules and are bussed to the system Fault Module. The Fault Module can be silenced for any successive faults. All faults will be locally announced at their respective modules and transferred at the Fault Module. All audible appliances can be silenced locally or remotely. An inhibit function is provided to allow system testing of all operations without solenoid activation. The panel cannot be reset until all active alarms have been cleared. Aircraft hangars Chemical plants Nuclear power plants Off shore oil platforms Co-generation power plants Natural gas compressor stations Petroleum products pumping stations 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com PROTECTION QUALITY AND RELIABILITY The system is protected from reverse voltage polarity, power surges, and RFI energy. Under voltage or over voltage from the redundant power source will induce a fault and be displayed on the Fault Module. A cover protector plate spans the length of the rack, containing the wire and associated terminal strips. Flow through ventilation allows cool and silent operation without the need of forced air. The optional locking clear Plexiglas door opens for total access to the front of the panel. High quality components are carefully selected for the manufacturing of the panel. All output relays are sealed and contain an inert gas to prevent contacts from oxidizing. All standard resistors are carbon composition quality. Precision resistors selected are long term stability military type conformal coated RN series. All contact mating surfaces are gold plated to enhance signal conduction and reduce oxidation. Printed circuit boards contain double sided plated through holes. Solder mask is over bare copper to prevent wetting action from wave and IR soldering. All modules are cycled with elevated heat in the environmental chamber prior to testing. POWER Allestec has designed the panel to accept customer available redundant power supplies. Although the panel is designed and approved for 20 - 28VDC operation, a source voltage as low as 14VDC will operate panel. SPECIFICATIONS ELECTRICAL Approved operating voltage: Customer supplied 20 - 28 VDC redundant power sources Absolute lowest operating voltage: 14 VDC System power requirements: Dependent on quantity and type of modules installed Dry relay outputs: 5 amps, 30 VDC resistive All output relays sealed and contains an inert gas Relays customer selective for N.O. or N.C. ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing RFI interference: Meets Factory Mutual specification as listed in Class #3820 Packaging and exposure: NEMA 1 REPRESENTED BY: 800 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls MODULE ENCLOSURE The Allestec model 800 expandable panel accommodates all modules of the 800 series gas and fire suppression family. Constructed of durable .1" zinc chromate plated steel, the heavy-duty housing is designed for rigorous use in industrial and high hazard environments. The standard EIA 19" rack can be custom ordered to any length, occupying minimum space while maximizing configurations. Matching blank modules can be ordered to occupy any open slots. The maximum height of the rack is only 3.5" and is supplied with a locking clear Plexiglas door. An alternative architect bezel kit (shown) is also available. SYSTEM MOTHER BOARD The back of the panel assembly incorporates a full-length motherboard allowing the transfer of signal communication between the modules. Durable Phoenix terminal strips are connected to the customer accessible rear panel allowing easy wire insertion by the 45 degree angle of the connectors. The motherboard terminal block connections are designated by the copper etch on the board itself and by the label located directly on the terminal strips. EIA industry standard rack expandable up to 19" High current 5 amp AC or DC relay connections Screw latch locks modules in place Gold plated card edge connectors All modules bussed to each other Only 3.5" high Steel housing reduces RF penetration User specified polarized keying of module location Up to four isolated zones REPRESENTED BY: Power and ground terminals are located below the main terminal strip and accommodate dual power supply connections. This power plane is bussed across the motherboard, supplying power to all modules and their respective appliances connected to the terminals. 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS 1690 ACCOMMODATIONS: Maximum 16 modules MOUNTING POSITION: Any angle ELECTRICAL CHARACTERISTICS: No active device other than transient suppression Terminal connections rated at 5 amps, 30 VDC Contact Allestec for AC operation WEIGHT AT 19”: 7.5 lbs. MATERIAL HOUSING: .1” thick Zinc chromate plated steel side panels, top and bottom are .059” thick Housing assists in the attenuation of induced RF radiation BACK PLANE MOTHER BOARD: 3/32” thick FR4 two-ounce fiberglass, UL listed Double sided plated printed circuit board Solder mask on both sides of board MODULE LOCATION: Any order except Fault Module required on right side of last module Polarizing keys supplied for final location of modules FIELD WIRE CONNECTIONS: Ten-position terminal strip for each module accepts up to a 14 AWG single or stranded conductor POWER CONNECTION: Screw type terminal blocks for 24 VDC connection of dual power supplies Terminal strip accepts up to 14 AWG single or stranded conductor PART NUMBER DESCRIPTION 800-1690-XX Rack assembly with low profile bezel - X represents number of slots required 800-1192-XX Rack assembly with front locking door - X represents number of slots required REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec model 1443D Release Module can accommodate a single or dual release application system. Conditions can be programmed to allow the reserve tank to extinguish if the main tank should fail or if the fire remains after the main tank discharges. Two independent time delays can be programmed into the module to control each discharge tank. Each solenoid circuit is rated at 24 VDC, 4 amps. The module can be located into an inhibit mode so the system can be tested without activating the solenoids. Other features include the ability to program an abort switch to add 30 seconds to the existing module timing sequence or activate a solenoid on the release of the abort button. Faults that are transmitted to the Fault Module include open solenoid circuit coil(s), open pressure line switch or open abort switch line. An auxiliary relay is activated at the time of the main tank activation. This relay is a SPDT contact, selectable with a 5 amp rating. REPRESENTED BY: Direct replacement for the model 1443 Release Module Solenoid driven system to allow for various agent releases Inhibit (disable) function allows system testing without activating the solenoids Ability to accommodate one or two release tanks Automatic backup mode protects against post ignition occurrence Abort and pressure switch can be optional accessories Microprocessor is fully programmed through the two membrane switches Non-volatile memory storage of configuration data Sonalert beeps at each second interval 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 70mA quiescent, 107mA alarm; no load Release solenoids: Two independent circuits source 24 VDC, 4 amps each Auxiliary discharge relay: Dry contact changes state on the first (main) release SPDT relay rated 5 amps, 30 VDC resistive, 250 VAC RELEASE Timed release: Two independent adjustable digital timers: Main time is: .1 to 9.9 minutes, Reserve time is: .2 to 9.9 minutes OTHER FUNCTIONS Abort output: (delayed or on abort release) 24 VDC output during time count down Clock sync output: 1 Hz, 24 VDC during time count down External reset: Open TB1-6 terminal from negative will reset timing sequence; input normally grounded MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 4.0 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART DESCRIPTION 800-1443D Release Module - standard label 800-1186 System Manual TYPICAL WIRING 1443D REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec model 1820 Release Module can accommodate a single or dual release applicat ion syst em. Conditions can be programmed to allow the reserve tank to extinguish if the main tank should fail or if the fire remains after the main tank discharges. Two inde - p e n d e nt t ime d e la y s c a n b e programmed into the module to control each discharge tank. Each solenoid circuit is rated at 24 VDC, 4 amps. The module can be located into an inhibit mode so the system can be tested without activating the solenoids. Other features include the ability to program an abort switch to add 30 seconds to the existing module timing sequence or activate a solenoid on the release of the abort button. Faults that are transmitted to the Fault Module include open solenoid circuit coil(s), open pressure line switch or open abort switch line. An auxiliary relay is activated at the time of the main tank activation. This relay is a SPDT contact, selectable with a 5 amp rating. REPRESENTED BY: Beckons the Status Module Solenoid driven system to allow for various agent releases Inhibit (disable) function allows system testing without activating the solenoids Ability to accommodate one or two release tanks Automatic backup mode protects against post ignition occurrence Abort and pressure switch can be optional accessories Microprocessor is fully programmed through the two membrane switches Non-volatile memory storage of configuration data Sonalert beeps at each second interval 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 70mA quiescent, 107mA alarm; no load Release solenoids: Two independent circuits source 24 VDC, 4 amps each Auxiliary discharge relay: Dry contact changes state on the first (main) release SPDT relay rated 5 amps, 30 VDC resistive, 250 VAC RELEASE Timed release: Two independent adjustable digital timers: Main time is: .1 to 9.9 minutes, Reserve time is: .2 to 9.9 minutes OTHER FUNCTIONS Copy Input for external fault monitoring Clock sync output: 1 Hz, 24 VDC during time count down External reset: Open TB1-6 terminal from negative will reset timing sequence; input normally grounded MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 4.0 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART DESCRIPTION 800-1820 Release Module - standard label 800-1186 System Manual Refer to you distributor for correct field wiring installation. 1820 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls Systems requiring an alternative method from other suppression agents can utilize the Allestec 800-2800 Cycle Release Module. A pre-discharge time can be programmed into the module prior to allowing to initiating the mist cycle sequence. This delay allows for personnel evacuation at which time the Alarm Module will be initiated. The Cycle Release Module is designed to sustain a mist spray from a pre-determined on/off cycle time. It then enters into a pause mode to assess the existence of a remaining fire or a post ignition occurance, then acts upon the situation by implementing another water mist cycle. During each cycle of operation, the display indicates the time remaining for the cycle, the cycle count and if the unit is in a pause mode. LEDs also indicate when the mist valve is in the open or closed position as well as pause mode. The module can be located into an inhibit mode so the system can be tested without activating the solenoids Fault conditions are transmitted to the Fault Module and also trip a local fault relay. REPRESENTED BY: Programmable to cycle the water mist delivery system including a pause mode Inhibit (disable) function allows system testing without the activating the release solenoids Ability to accommodate one 24 VDC or two series 12 VDC release solenoids Microprocessor controlled and programmed through the panel two membrane switches Non-volatile data configuration storage Applications include oil refineries, industrial electrical equipment, flammable liquid pumping and storage facilities, co-generation power plants, etc. Conforms to NFPA 750. Accessible SPDT fault relay Remote reset input Auxiliary programmable CPU input for special conditions Sonalert beeps at each timing interval 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 75mA quiescent, 75mA alarm Release output: One circuit sources at 24 VDC, 3A hold, 6A trip Fault relay: Rated 5A, 30 VDC, 250 VAC RELEASE Pre-discharge: Adjustable from 0 to 99 seconds Mist on/off cycle: Adjustable from 5 to 99 seconds Cycle time counts (if fire is extinguished up to the first pause mode): Adjustable from 1 to 9 counts Pause mode timing: Adjustable from .1 to 9.9 minutes OTHER FUNCTIONS Clock sync output: 1 Hz, 24 VDC during time count down (optional) External reset: Provide momentary + 24 VDC to TB2-3 terminal MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 4.0 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-2800 Cycle Release Module 800-1186 System Manual TYPICAL WIRING 2800 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec Alarm Module, model number 1442, is programmable from other modules within the panel assembly to facilitate in the announcement of audio and visual external appliances. An alarm signal will turn on channel one, normally the bell channel. Channel two, the horn circuit, is simultaneously turned on. A silence switch is provided to silence the audible alarm(s) or any successive alarms. The strobe circuit located on channel three, remains in the alarm condition until the primary Input Module(s) can be reset. This safety feature ensures that all alarms have been cleared before the Alarm Module strobe channel can be reset. An external input allows the remote field activation of the Alarm Module. This input duplicates the function of the other modules connected through the motherboard buss. The remote silence input, or the silence switch located on the front panel, can then be depressed to silence the appliances. Any reoccurrence of alarms, locally or remotely, will activate the module again. Each output is individually monitored for a fault condition. A fault will be announced with its respective yellow fault LED and will activate the Fault Module. Three appliance channels Remote trip and silence inputs LED local alarm annunciation All field wiring supervised per NFPA REPRESENTED BY: 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current excluding appliances: 30mA quiescent, 90mA maximum Relay outputs: Three relays fused at 2 amps each, 24 VDC Output relays sealed and contains an inert gas Alarm mode: Utilizes reverse polarity on alarm, supplying 24 VDC to the appliances MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.8 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing RFI interference: Meets Factory Mutual specification as listed in Class #3820 Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1442 Alarm Module 800-1211 End of line resistors (3 supplied) - may not be required on all appliances 800-1186 System manual TYPICAL WIRING 1442 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec model 1457 NT420 Gas Module monitors industry standard 4-20 mA output signals, allowing a real time digital display of the input current. The NT420 is connected through the 800 panel motherboard buss and is able to beckon the Alarm, Fault and the Relay Modules. This module is capable of being utilized as a standalone module, or can be integrated with other Allestec modules. Programming is completed though the two front panel membrane switches. A sonalert responds to each command as the parameters are entered. While in the program mode, all relay outputs are disabled and the fault circuit is active. For each alarm level, the respective relay output will energize and follow its latching mode as established in the program setup. The program mode is also capable of displaying the actual 420mA loop current in real time. This feature can be utilized for loop current diagnostics for system servicing. An optional 4-20mA output is available for a recorder or similar type of measuring instrument. This output signal is an exact duplicate of the input signal and has no influence on the module calibration. REPRESENTED BY: Fully programmable from front panel No potentiometers to adjust Prevent sensor drift of display utilizing a dead band area Three levels of alarm set points with relating relays All user adjustments executed with two membrane switches Real time digital display from 0 to 100 %LFL, PPM, or % input current Real time digital display of 4-20mA current Optional 4-20mA recorder output Under range, over range, over current, fault annunciation 24VDC open collector fault output, failsafe mode Ability to beckon Allestec Alarm, Fault and Relay Module DESIGN FEATURES True analog to digital conversion True digital display representation of loop current Linear scale Integral microprocessor design Digital filter Display digit fluctuating inhibitor Memory retention with loss of power 100 milliseconds loop current sampling rate Peak hold of 4-20mA signal prevents display dither 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC power source Operating current: Quiescent with input = 4mA: 85mA Maximum alarm with input = 20mA: 130mA Dry relay outputs: 5 amps, 30 VDC resistive, 250 VAC Output relay sealed and contains an inert gas Relays are selective for N.O. or N.C. Sensor / transmitter output 24 VDC power: Fused for 3 amps DISPLAY Red seven segment displays: Low scale displays “ur” for under range, then -10 to 00 High scale displays 1H for 100, the “or” for over range and “oc” for over current Dominant wavelength: 640nm Segment height: .3” high Display LEDs: Red - HIHI indicates high high alarm Red - HI indicates high alarm Orange - LO indicates low alarm Yellow - FAULT indicates fault condition MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 4.2 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1457-1454 NT420 Gas detection module %LFL 800-1457-1489 NT420 Gas detection module PPM 800-1457-1490 NT420 Analog input module % 800-1186 System manual TYPICAL WIRING 1457 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The model 1440 Input Module is the initiating module which connects up to three independent dry relay contacts from detector outputs. Adding additional modules expands the number of points of fire detection in three point increments. The three discrete inputs can be voted between each other adding confidence to the system. Output relay is individually controlled from the DIP switch configuration. The Alarm, Release and Relay Modules are activated in a pre-selected sequence established from the DIP switch configurations. Inputs are individually monitored for a fault condition. A fault will be announced with its respective yellow fault LED and will activate the Fault Module. The detector power output fuse is monitored and rated for 2 amps. REPRESENTED BY: Three independent inputs applicable to any dry input contact device, such as optical, smoke, or heat detectors Three independent input time delays adjustable from 0 to 15 seconds Auxiliary form C fire relay can be independently voted Relay is selective for latching or nonlatching Memory feature allows alarm LED to remain on during alarm and blinks when alarm clears Input voting capability has independent control transferred to Alarm Module and Release Module Recessed detector test switch option able to source or sink current Detector fused power output and reset switch All field wiring supervised per NFPA requirement 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 31mA quiescent, 65mA alarm Detector power source fuse rating: 2 amps DC Dry relay outputs: 5 amps, 30 VDC resistive Output relay sealed and contains an inert gas Auxiliary fire relay is customer selective for latching or non-latching Relay is form C configuration MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.7 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing RFI interference: Meets Factory Mutual specification as listed in Class #3820 Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1440 Input Module 800-1211 End of line resistors, 3 supplied 800-1378 Test switch rod 800-1186 System manual TYPICAL WIRING 1440 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls Single or multiple cascaded pull stations independently operate the Model 1441 Manual Pull Module. This module has many features that allow the customer to configure the release system in accordance with local jurisdictions. Activating the Manual Pull Module will result in its local relay transfer and beckoned the Alarm, Release and Relay Modules. Customer has options to select instant or pre-determined time delay on release mechanism located at the Release Module. The ability to control the discharge of one or two tanks is also selectable. An inhibit switch allows system testing while preventing the release mechanism from actuating. The customer is aware of the inhibit by the blinking inhibit LED and annunciation of the Fault Module. The Alarm Module will activate upon receiving the contact closure of a pull station. The Manual Pull Module input is individually monitored for a fault condition. A fault will be announced with its respective yellow fault LED and will activate the Fault Module. Multiple manual pull stations monitored Inhibit feature allows system testing Auxiliary form C output relay Ability to select instant or delayed agent release Ability to select one or two tank discharges All field wiring supervised per NFPA REPRESENTED BY: 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 25mA quiescent, 42mA alarm Dry relay outputs: 5 amps, 30 VDC resistive Output relay sealed and contains an inert gas Relay is form C configuration MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.1 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing RFI interference: Meets Factory Mutual specification as listed in Class #3820 Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1441 Manual Pull Module 800-1211 End of line resistors, 1 supplied 800-1186 System manual TYPICAL WIRING 1441 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Fault Module is a common system annunciator triggered by any faults in the system. All faults are displayed locally on each module but are also transmitted centrally to the Fault Module, sounding a sonalert. The sonalert can be silenced while determining the source of the fault. A fault will be noted with the system fault LED and de-energize the failsafe fault relay output. A protection circuit monitors the power supply voltage for under or over voltage inputs. Should the power supply voltage deviate from its required specification, the system fault LED will illuminate and the sonalert will sound, followed by the relay changing state. An auxiliary normally closed input is provided to monitor any dry contacts. If the contact is open, the auxiliary LED will illuminate and the sonalert will sound followed by the relay changing state. Monitors complete 800 panel Announces the removal of any module Announces any open fuses Fault relay output DC low and high voltage limit monitoring Auxiliary fault input connection Audible fault can be silenced All field wiring supervised per NFPA REPRESENTED BY: 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 31mA quiescent, 40mA maximum Dry relay outputs: 5 amps, 30 VDC resistive Output relay sealed and contains an inert gas Relay is form C configuration MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.1 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing RFI interference: Meets Factory Mutual specification as listed in Class #3820 Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1444 Fault Module 800-1186 System manual TYPICAL WIRING 1444 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls Model 1530 Input Module is a primary detector module that accepts two independent dry relay contacts from initiating devices. This module can vote between its local two input channels as well as other Input Vote Modules, requiring the combination of up to four valid alarms to confirm the alar m co nd it io n. The vo t ing configuration can trip the Alarm, Release and Relay Modules based on DIP switch settings. Inputs are individually monitored for a fault condition. A fault will be announced with its respective yellow fault LED and will activate the Fault Module. The detector power output fuse is monitored and rated at 3A. REPRESENTED BY: Module can occupy same rack as three channel model 1440 Input Module Accepts two independent inputs applicable to any dry input contact device, such as optical, smoke, or heat detectors Optional time delays are adjustable from 0 to 15 seconds for each input Auxiliary form C fire relay can be independently voted Relay is selective for latching or nonlatching Memory feature allows alarm LED to remain on during alarm and blinks when alarm clears Input voting capability has independent control transferred to Alarm Module and Release Module Recessed detector test switch option able to source or sink current Individual open collector outputs for each channel operate in failsafe mode Detector fused power output and reset switch All field wiring supervised per NFPA requirement 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 30mA quiescent, 54mA alarm Detector power source fuse rating: 3 amps Dry relay outputs: 5 amps, 30 VDC resistive, 250 VAC Output relay sealed and contains an inert gas Auxiliary fire relay is customer selective for latching or non-latching Relay is form C configuration MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.7 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1530 Input Module 800-1211 End of line resistors, 2 supplied 800-1378 Test switch rod 800-1186 System manual TYPICAL WIRING 1530 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec Abort Module is designed to be connected to the Model 800 fire panel and other fire panels requiring abort function. Standard 3 gang mounting and stainless steel bezel allow the unit to be placed in many locations. Digital display remains blank until the module receives its 24 VDC start signal. LED digits are legible in bright daylight from a distance of 12 feet. Pressing the abort switch resets the display(s) back to zero. Audible sonalert during time count Power LED Small 3 gang size Optional dual display Available clock sync input Low power CMOS design Internal voltage regulation Aesthetic enhanced design REPRESENTED BY: APPLICATIONS Oil refineries Chemical plants Co-generating power plants Natural gas pumping stations Aircraft hangars Industrial 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS OPERATING VOLTAGE: 20-28 VDC OPERATING CURRENT: Primary Board: 18mA Quiescent, 105mA Maximum Secondary Board Option: 21mA Quiescent, 185mA Maximum FUSE F1: Primary Board: 125mA P/N 1394 Secondary Board Installed: 250mA P/N 1414 AUDIBLE: Sonalert pulse 1 cycle per second during count down Frequency: 3.8 Khz @ 75dB 1m ENVIRONMENT: Temperature Range: 0 degrees F - 150 degrees F Humidity: Non-condensing 0 - 95% CONSTRUCTION: Bezel: Stainless Steel Printed Circuit Board: 1/16” two ounce copper, FR-4 fiberglass, double sided, plated through holes, solder MOUNTING: Standard 3 gang wall mount switch box PART NUMBER DESCRIPTION 800-1436 Single Display Abort Module 800-1437 Dual Display Abort Module 800-1186 System manual NOTE: Refer to the Release Module, P/N 1443D for field wiring. 1436 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec model 1760 Relay Module allows additional relay functions to assist the available outputs of the 800 panel. Three relays can be configured to change state when a certain condition occurs within the panel. Two relays are directed to the general alarm module while one relay is retained for system faults. Relays can be configured for latching or non-latching and failsafe operation. An LED is associated with each of the three relays. The LED is illuminated only when a relay changes state. A sonalert is provided that emits a chirping sound whenever a relay changes state. The sonalert can be silenced while a relay remains activated. Three system relays available for various alarm conditions Relays are SPDT, all three contacts for each relay are accessible Sonalert sounds on any of the three relays changing state An LED indicates which relay is activated Optional external reset available REPRESENTED BY: 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 20mA quiescent, 90mA alarm Dry relay outputs: General, auxiliary, fault relays 5 amps, 30 VDC resistive, 250 VAC Output relays are sealed and contains an inert gas Relays are form C configuration MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 3.7 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART NUMBER DESCRIPTION 800-1760 Relay Module 800-1186 System manual TYPICAL WIRING 1760 REV B © 2001 ALLESTEC CORP. Modular Special Hazard Safety Controls The Allestec model 1820 Release Module can accommodate a single or dual release application system. Conditions can be programmed to allow the reserve tank to extinguish if the main tank should fail or if the fire remains after the main tank discharges. Two inde-pendent time delays can be programmed into the module to control each discharge tank. Each solenoid circuit is rated at 24 VDC, 4 amps. The module can be located into an inhibit mode so the system can be tested without activating the solenoids. Other features include the ability to program an abort switch to add 30 seconds to the existing module timing sequence or activate a solenoid on the release of the abort button. Faults that are transmitted to the Fault Module include open solenoid circuit coil(s), open pressure line switch or open abort switch line. An auxiliary relay is activated at the time of the main tank activation. This relay is a SPDT contact, selectable with a 5 amp rating. Solenoid driven system to allow for various agent releases Inhibit (disable) function allows system testing without activating the solenoids Ability to accommodate one or two release tanks Automatic backup mode protects against post ignition occurrence Abort and pressure switch can be optional accessories Microprocessor is fully programmed through the two membrane switches Non-volatile memory storage of configuration data Sonalert beeps at each second interval REPRESENTED BY: 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com SPECIFICATIONS ELECTRICAL Approved operating voltage: 20 - 28 VDC redundant power sources Operating current: 70mA quiescent, 107mA alarm; no load Release solenoids: Two independent circuits source 24 VDC, 4 amps each Auxiliary discharge relay: Dry contact changes state on the first (main) release SPDT relay rated 5 amps, 30 VDC resistive, 250 VAC RELEASE Timed release: Two independent adjustable digital timers: Main time is: .1 to 9.9 minutes, Reserve time is: .2 to 9.9 minutes OTHER FUNCTIONS Abort output: (delayed or on abort release) 24 VDC output during time count down Clock sync output: 1 Hz, 24 VDC during time count down External reset: Open TB1-6 terminal from negative will reset timing sequence; input normally grounded MECHANICAL Size: 1.04”W X 3.46”H X 6.4”D Weight: 4.0 ounces ENVIRONMENT Ambient operating temperature: 0 degrees F to 150 degrees F, -17 degrees C to 65 degrees C, 90% humidity non-condensing Packaging and exposure: NEMA 1 PART DESCRIPTION 800-1820 Release Module 800-1186 System Manual 810 russell palmer road kingwood, texas 77339 p.o. box 6092 KINGWOOD, TEXAS 77325 PHONE: 281-359-1519 FAX: 281-359-2085 www.ALLESTEC.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement