scalance w788c-2 - Siemens Support

scalance w788c-2 - Siemens Support
1
___________________
Introduction
Security recommendations
SIMATIC NET
Industrial Wireless LAN
SCALANCE W788C-2
Operating Instructions
2
3
___________________
Description
4
___________________
Mounting
5
___________________
Connection
Technical data
6
___________________
7
Dimension drawings
___________________
8
Approvals
01/2017
A5E03692120-11
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
A5E03692120-11
Ⓟ 01/2017 Subject to change
Copyright © Siemens AG 2011 - 2017.
All rights reserved
Table of contents
1
Introduction ............................................................................................................................................. 5
1.1
Information on the Operating Instructions ................................................................................ 5
2
Security recommendations ...................................................................................................................... 7
3
Description ............................................................................................................................................ 11
4
5
6
3.1
Description of the device ........................................................................................................11
3.2
Structure of the type designations ..........................................................................................13
3.3
Components of the product ....................................................................................................14
3.4
3.4.1
3.4.2
3.4.2.1
3.4.2.2
Accessories .............................................................................................................................15
Installation ...............................................................................................................................15
Flexible connecting cables and antennas ...............................................................................18
Flexible connecting cables ......................................................................................................18
Antennas .................................................................................................................................19
3.5
LED display .............................................................................................................................22
Mounting ............................................................................................................................................... 23
4.1
Securing the housing ..............................................................................................................24
4.2
Wall mounting .........................................................................................................................25
4.3
Installing on the S7-300 standard rail .....................................................................................26
4.4
Installing on a DIN rail .............................................................................................................27
Connection ........................................................................................................................................... 29
5.1
Safety when connecting up .....................................................................................................29
5.2
Lightning protection, power supply and grounding .................................................................30
5.3
Power supply and Ethernet .....................................................................................................33
5.4
Antenna connectors ................................................................................................................35
Technical data ...................................................................................................................................... 39
6.1
Technical specifications of the SCALANCE W788C-2) ..........................................................39
7
Dimension drawings .............................................................................................................................. 43
8
Approvals.............................................................................................................................................. 45
Index..................................................................................................................................................... 47
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
3
Table of contents
SCALANCE W788C-2
4
Operating Instructions, 01/2017, A5E03692120-11
1
Introduction
1.1
Information on the Operating Instructions
Validity of the Operating Instructions
These operating instructions cover the following products:
Product
Article number
SCALANCE W788C-2 RJ-45
6GK5 788-2FC00-1AA0
SCALANCE W788C-2 M12
6GK5 788-2GD00-1AA0
SCALANCE W788C-2 M12 EEC
6GK5788-2GD00-1TA0
If information relates to all the named products, the term SCALANCE W7x8 will be used.
These operating instructions apply to the following software version:
● SCALANCE W7x8C with firmware as of version 8.31
Purpose of the Operating Instructions
Using the Operating Instructions, you will be able to install and connect the SCALANCE
W7x8 correctly. The configuration and the integration of the device in a WLAN are not
described in these instructions.
Documentation on the accompanying CD
You will find introductory information about configuration in the document "Getting Started
SCALANCE WLC711" on the accompanying SIMATIC NET IWLAN CD under the file name:
GS_SCALANCE-WLC711_76 pdf
Note
Detection of the W788C-2 M12 EEC devices
When the W788C-2 M12 EEC devices are detected by the configuration software of the
WLC 711, they are shown as W788C-2 M12.
Note
Make sure that you read the explanations and instructions in the README.txt file
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
5
Introduction
1.1 Information on the Operating Instructions
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines
and networks. Systems, machines and components should only be connected to the
enterprise network or the internet if and to the extent necessary and with appropriate security
measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit
http://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity)
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends to apply product updates as soon as available and to
always use the latest product versions. Use of product versions that are no longer supported,
and failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
http://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity)
Trademarks
The following and possibly other names not identified by the registered trademark sign ® are
registered trademarks of Siemens AG:
SIMATIC NET, SCALANCE, C-PLUG, RCOAX
SCALANCE W788C-2
6
Operating Instructions, 01/2017, A5E03692120-11
Security recommendations
2
To prevent unauthorized access, note the following security recommendations.
General
● You should make regular checks to make sure that the device meets these
recommendations and/or other security guidelines.
● Evaluate your plant as a whole in terms of security. Use a cell protection concept with
suitable products.
● When the internal and external network are disconnected, an attacker cannot access
internal data from the outside. Therefore operate the device only within a protected
network area.
● For communication via non-secure networks use additional devices with VPN functionality
to encrypt and authenticate the communication.
● Terminate management connections correctly (WBM. Telnet, SSH etc.).
Physical access
● Restrict physical access to the device to qualified personnel.
● The memory card or the PLUG (C-PLUG, KEY-PLUG, security PLUG) contains sensitive
data such as certificates, keys etc. that can be read out and modified.
Software (security functions)
● Keep the software up to date. Check regularly for security updates of the product.
You will find information on this on the Internet pages "Industrial Security
(http://www.siemens.com/industrialsecurity)".
● Inform yourself regularly about security advisories and bulletins published by Siemens
ProductCERT (http://www.siemens.com/cert/en/cert-security-advisories.htm).
● Only activate protocols that you really require to use the device.
● Use the security functions such as address translation with NAT (Network Address
Translation) or NAPT (Network Address Port Translation) to protect receiving ports from
access by third parties.
● Restrict access to the device with a firewall or rules in an access control list (ACL Access Control List).
● If RADIUS authentication is via remote access, make sure that the communication is
within the secured network area or is via a secure channel.
● The option of VLAN structuring provides good protection against DoS attacks and
unauthorized access. Check whether this is practical or useful in your environment.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
7
Security recommendations
● Enable logging functions. Use the central logging function to log changes and access
attempts centrally. Check the logging information regularly.
● Configure a Syslog server to forward all logs to a central location.
● Use WPA2/ WPA2-PSK with AES to protect the WLAN. If iPCF or iPCF-MC is used, use
the AES encryption.
Passwords
● Define rules for the use of devices and assignment of passwords.
● Regularly update passwords and keys to increase security.
● Change all default passwords for users before you operate the device.
● Only use passwords with a high password strength. Avoid weak passwords for example
password1, 123456789, abcdefgh.
● Make sure that all passwords are protected and inaccessible to unauthorized personnel.
● Do not use the same password for different users and systems or after it has expired.
Keys and certificates
This section deals with the security keys and certificates you require to set up HTTPS (
HyperText Transfer Protocol Secured Socket Layer).
● We strongly recommend that you create your own HTTPS certificates and make them
available.
There are preset certificates and keys on the device. The preset and automatically
created HTTPS certificates are self-signed.
We recommend that you use HTTPS certificates signed either by a reliable external or by
an internal certification authority. The HTTPS certificate checks the identity of the device
and controls the encrypted data exchange. You can install the HTTPS certificate via the
WBM (System > Load and Save).
● Handle user-defined private keys with great caution if you use user-defined SSH or SSL
keys.
● Use the certification authority including key revocation and management to sign the
certificates.
● Verify certificates and fingerprints on the server and client to avoid "man in the middle"
attacks.
● We recommend that you use certificates with a key length of 2048 bits.
● Change keys and certificates immediately, if there is a suspicion of compromise.
Secure/non-secure protocols
● For the DCP function, enable the "DCP read-only" mode after commissioning.
● Avoid and disable non-secure protocols, for example Telnet and TFTP. For historical
reasons, these protocols are still available, however not intended for secure applications.
Use non-secure protocols on the device with caution.
SCALANCE W788C-2
8
Operating Instructions, 01/2017, A5E03692120-11
Security recommendations
● The following protocols provide secure alternatives:
– SNMPv1/v2 → SNMPv3
Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure.
Use the option of preventing write access. The product provides you with suitable
setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use SNMPv3 in conjunction with passwords.
– HTTP → HTTPS
– Telnet → SSH
– SNTP → NTP
● Use secure protocols when access to the device is not prevented by physical protection
measures.
● To prevent unauthorized access to the device or network, take suitable protective
measures against non-secure protocols.
● If you require non-secure protocols and services, operate the device only within a
protected network area.
● Restrict the services and protocols available to the outside to a minimum.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
9
Security recommendations
Available protocols per port
The following list provides you with an overview of the open ports on this device.
The table includes the following columns:
● Protocol
All protocols that the device supports
● Port number
Port number assigned to the protocol
● Port status
– Open
The port is always open and cannot be closed.
– Open (when configured)
The port is open if it has been configured.
● Factory setting
– Open
The factory setting of the port is "Open".
– Closed
The factory setting of the port is "Closed".
● Authentication
Specifies whether or not the protocol is authenticated.
Protocol
Port number
Port status
Factory setting
of the port
Authentication
SSH
TCP/22
Open (when configured)
Open
Yes
TELNET
TCP/23
Open (when configured)
Open
Yes
HTTP
TCP/80
Open (when configured)
Open
Yes
HTTPS
TCP/443
Open (when configured)
Open
Yes
SNTP
UDP/123
Open (when configured)
Closed
No
SNMP
UDP/161
Open (when configured)
Open
Yes
PROFINET
UDP/34964,
UDP/49154,
49155
Open
Open
No
Syslog
UDP/514
Open (when configured)
Open
No
EtherNet/IP
TCP/44818,
UDP/2222,4481
8
Open (when configured)
Open
No
DHCP
UDP/67,68
Open (when configured)
Closed
No
RADIUS
UDP/1812,1813
Open (when configured)
Closed
No
TFTP
UDP/69
Open (when configured)
Closed
No
NTP
SCALANCE W788C-2
10
Operating Instructions, 01/2017, A5E03692120-11
3
Description
3.1
Description of the device
W7x8x-x RJ-45 - degree of protection IP30
①
②
LEDs
Connecting connectors, R-SMA type female
•
Devices with one IWLAN interface: 3 connectors on the top (covered in the figure).
•
Devices with two IWLAN interfaces: 3 connectors on the top and 3 on the underside.
③
④
⑤
Connector for power supply
⑥
⑦
⑧
⑨
Connector for the digital input/output (not with W788C)
Connector for Ethernet, RJ-45 type
Screw-down cover for the
- reset button and the
- PLUG compartment (not with W788C)
PLUG compartment (not with W788C)
Reset button
Grounding connector (thread M4) on the back of the device
Figure 3-1
Device description of the RJ-45 variant
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
11
Description
3.1 Description of the device
W7x8x-x M12 - degree of protection IP65
①
Connecting connectors, N-Connect type female
•
Devices with one IWLAN interface: 3 connectors on the top (covered in the figure).
•
Devices with two IWLAN interfaces: 3 connectors on the top and 3 on the underside.
②
③
④
⑤
LEDs
⑥
⑦
⑧
PLUG compartment (not with W788C)
Connector for the supply voltage, type M12 (with cover)
Connector for Ethernet, M12 type (with cover)
Screw-down cover for the
- reset button and the
- PLUG compartment (not with W788C)
Reset button (covered in the figure)
Grounding connector (thread M4) on the back of the device
Figure 3-2
Device description of the M12 variant
SCALANCE W788C-2
12
Operating Instructions, 01/2017, A5E03692120-11
Description
3.2 Structure of the type designations
3.2
Structure of the type designations
The type designation of a SCALANCE W7x8 is made up of several parts that have the
following meaning:
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
13
Description
3.3 Components of the product
3.3
Components of the product
The following components are supplied with the product:
● SCALANCE W7x8
● Only with device variant M12 / IP65:
– 2 protective caps for the M12 sockets
● Only with device variant RJ-45 / IP30:
– 4-pin terminal block for the supply voltage
– 4-pin terminal block for the digital input/output
● 2 screws for mounting on an S7-300 standard rail
● SIMATIC NET Industrial Wireless LAN CD
Note
The mounting set with the holding plate does not ship with the device, see Accessories
(Page 15).
Please check that the consignment you have received is complete. If the consignment is
incomplete, contact your supplier or your local Siemens office.
SCALANCE W788C-2
14
Operating Instructions, 01/2017, A5E03692120-11
Description
3.4 Accessories
3.4
Accessories
Technical data subject to change.
You will find further information on the accessories program in the Industry Mall.
(https://mall.industry.siemens.com)
3.4.1
Installation
Installation
Component
Description
Article number
Mounting set
The mounting set with the holding plate for attachment to an S7-300 rail, a 35 mm DIN rail or a mast.
6GK5798-8ML00-0AB3
M12 data plug-in connector
Component
Description
Article number
IE FC M12
PLUG PRO
2x2
M12 data plug-in connector for IE FC
TP cables 2x2, IP65/67, D-coded,
axial cable outlet
1 connector per
package
6GK1 901-0DB20-6AA0
8 connectors per
package
6GK1 901-0DB20-6AA8
Data line
Component
Description
IE FC TP STANDARD
CABLE GP2X2
Standard bus cable, TP installation cable for con- 6XV1 840-2AH10
nection to FC OUTLET RJ-45, for universal use, 4wire, shielded, CAT 5E
(PROFINET type A)
IE FC TP ROBUST
STANDARD CABLE GP
2X2
(PROFINET type A)
Article number
Sold by the meter
Standard bus cable, ATPE outer jacket for connection to FC RJ-45 PLUG and FC OUTLET RJ45, fixed installation, for universal use, 4-wire,
shielded, CAT 5
6XV1 841-2A
Sold by the meter
IE FC TP ROBUST
FLEXIBLE CABLE GP
2X2
Flexible bus cable, TPE outer jacket for connection to FC RJ-45 PLUG and FC OUTLET RJ-45,
flexible wires, 4-wire, shielded, CAT 5
(PROFINET type B)
Sold by the meter
IE FC TP FLEXIBLE
CABLE GP 2X2
Flexible bus cable, TP installation cable, flexible
wires, shielded, CAT 5
(PROFINET type B)
Sold by the meter
6XV1 841-2B
6XV1 870-2B
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
15
Description
3.4 Accessories
Component
Description
Article number
IE FC TP TRAILING
CABLE 2X2
6XV1 840-3AH10
(PROFINET type C)
Highly flexible bus cable, TP installation cable for
connection to FC OUTLET RJ-45, for use in drag
chains, 4-wire, shielded, CAT 5
IE TP TORSION CABLE
2X2
Highly flexible bus cable, TP installation cable for
use in highly flexible applications (torsion), 4-wire
(PROFINET type C)
Sold by the meter
IE CONNECTING CABLE
M12-180/IE RJ45
Flexible IE connecting cable, 4-wire, preassembled with a 4-pin M12 plug (D-coded) and an IE
FC RJ-45 plug 145
6XV1 871-5T*
IE CONNECTING CABLE
M12-180/M12-180
Flexible IE connecting cable, 4-wire, preassembled with two 4-pin M12 plugs (D-coded)
6XV1 870-8A*
Sold by the meter
6XV1 870-2F
* Available in different lengths
Cabinet feedthrough
Component
Description
Article number
IE M12 PANEL
FEEDTHROUGH
Cabinet feedthrough for conversion from M12
connector technology (D-coded, IP65) to RJ-45
connector technology (IP20)
6GK1 901-0DM20-2AA5
pack of 5
IE M12 PANEL
FEEDTHROUGH
PRO
Cabinet feedthrough for conversion from M12
connector technology (D-coded, IP65) to M12
connector technology (D-coded, IP65)
6GK1 901-0DM30-2AA5
pack of 5
IE M12 PANEL
FEEDTHROUGH
4X2
Cabinet feedthrough for conversion from M12
6GK1 901-0DM40-2AA5
connector technology (X-coded, IP65/67) to RJ-45
connector technology (X-coded, IP20)
pack of 5
N-Connect/NConnect female/female Panel
Feedthrough
Panel feedthrough for wall thicknesses up to a
maximum of 4.5 mm, two N-Connect female connectors.
6GK5 798-2PP00-2AA6
N-Connect/SMAConnect female/female Panel
Feedthrough
Panel feedthrough for wall thicknesses up to a
maximum of 5.5 mm, two N-Connect/SMA female
connectors.
6GK5 798-0PT00-2AA6
SCALANCE W788C-2
16
Operating Instructions, 01/2017, A5E03692120-11
Description
3.4 Accessories
Energy cable
Component
Description
Article number
Energy cable 2
x 0.75
Energy cable for connection of signaling contact and power
supply 24 VDC, stranded wire 2 x 0.75 mm2, capable of trailing, not assembled
6XV1 812-8A
Sold by the meter
Robust Energy
Cable 4 x 0.75
Energy cable for connection of power supply 24 VDC, 4-wire
stranded 4 x 0.75 mm2, robust, flexible, not assembled
6XV1 801-2A
Sold by the meter
M12 PLUG-IN
CABLE
Flexible plug-in power cable to connect the power supply 24
VDC, 4-wire, preassembled with a 4-pin M12 plug and an
M12 socket (A-coded)
6XV1 801-5D*
* Available in different lengths
Socket
Component
Description
Article number
IE POWER M12
CABLE CONNECTOR
PRO
Socket for the 24 VDC power supply. 4-pin, Acoded
6GK1 907-0DC10-6AA3
pack of 3
Lightning protection
Component
Description
Article number
LP798-1N
Lighting protector with N/N female/female connector with
gas discharge technology
6GK5798-2LP00-2AA6
LP798-2N
Lighting protector with N/N female/female connector with
quarter wave technology
6GK5798-2LP10-2AA6
Component
Description
Article number
TI795-1N
Electrical connection
6GK5795-1TN00-1AA0
Terminating resistor
N-Connect, male
TI795-1R
Electrical connection
6GK5 795-1TR10-0AA6
RSMA-Connect, male
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
17
Description
3.4 Accessories
3.4.2
Flexible connecting cables and antennas
3.4.2.1
Flexible connecting cables
N-Connect/R-SMA flexible connecting cable for RJ-45
Flexible connecting cable for connecting an antenna to a SCALANCE W700. Preassembled
with two connectors N male and R-SMA male
Length
Article number
0.3 m
6XV1875-5CE30
1m
6XV1875-5CH10
2m
6XV1875-5CH20
5m
6XV1875-5CH50
10 m
6XV1875-5CN10
For railway applications, the following connecting cable are available:
Length
Article number
1m
6XV1875-5TH10
2m
6XV1875-5TH20
5m
6XV1875-5TH50
Flexible connecting cable N-Connect/N-Connect
Flexible connecting cable for connecting an antenna to a SCALANCE W700 with N-Connect
connectors.
Preassembled with two N male connectors:
Length
Article number
1m
6XV1875-5AH10
2m
6XV1875-5AH20
5m
6XV1875-5AH50
10 m
6XV1875-5AN10
For railway applications, the following connecting cable are available:
Length
Article number
1m
6XV1875-5SH10
2m
6XV1875-5SH20
5m
6XV1875-5SH50
SCALANCE W788C-2
18
Operating Instructions, 01/2017, A5E03692120-11
Description
3.4 Accessories
Flexible connecting cable IWLAN QMA/N-Connect male/female
Adapter cable for connecting a MIMO antenna with QMA connectors with the flexible
connecting cables. Preassembled with two connectors QMA male and N-Connect female.
pack of 3
Length
Article number
1m
6XV1875-5JH10
For railway applications, the following connecting cable is available Note: Scope of delivery:
Pack of 1
3.4.2.2
Length
Article number
1m
6XV1875-5VH10
Antennas
Note
When you select an antenna, keep in mind the national approvals for your device.
You will find more information in the following Link (http://www.siemens.com/wirelessapprovals)
The SCALANCE W786C-2IA RJ-45 uses internal omni antennas (3/4 dBi at 2.4 GHz or 5
GHz).
Type
Properties
Article number
ANT792-4DN
RCoax helical antenna, circular
polarization, 4 dBi, 2.4 GHz, NConnect female.
6GK5 792-4DN00-0AA6
ANT792-6MN
Omni antenna, mast/wall mounting, 6GK5 792-6MN00-0AA6
6 dBi 2.4 GHz, N-Connect female
ANT792-8DN
Directional antenna, mast/wall
mounting, 14 dBi 2.4 GHz, NConnect female
6GK5 792-8DN00-0AA6
ANT793-4MN
RCoax λ5/8 antenna with vertical
polarization, 6 dBi, 5 GHz, NConnect female.
6GK5 793-4MN00-0AA6
ANT793-6DG
Wide angle antenna, mast/wall
mounting, 9 dBi 5 GHz, 2 x NConnect female
6GK5 793-6DG00-0AA0
ANT793-6DT
Wide angle antenna (MIMO),
6GK5 793-6DT00-0AA0
mast/wall mounting, 8 dBi 5 GHz, 3
x QMA connector female
ANT793-6MN
Omni antenna, mast/wall mounting, 6GK5 793-6MN00-0AA6
5 dBi 5 GHz, N-Connect female
ANT793-8DJ
Directional antenna, mast/wall
mounting, 18 dBi 5 GHz, 2 x NConnect female
6GK5 793-8DJ00-0AA0
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
19
Description
3.4 Accessories
Type
Properties
Article number
ANT793-8DK
Directional antenna, mast/wall
mounting, 23 dBi 5 GHz, 2 x NConnect female
6GK5 793-8DK00-0AA0
ANT795-4MA
Omni antenna, directly on the device, 3/5 dBi 2.4 GHz and 5 GHz,
IP30, R-SMA connector male for
direct mounting on the device,
connector angle adjustable 0° to
180°.
6GK5 795-4MA00-0AA3
ANT795-4MC
Omnidirectional antenna, 3/5 dBi,
2.4 GHz and 5 GHz, IP65, NConnect male for direct installation
on the device, straight connector.
6GK5 795-4MC00-0AA3
ANT795-4MD
Omnidirectional antenna, 3/5 dBi,
2.4 GHz and 5 GHz, IP65, NConnect male for direct installation
on the device, 90° connector.
6GK5 795-4MD00-0AA3
ANT795-6DC
Wide angle antenna, mast/wall
mounting, 9 dBi 2.4 GHz and 5
GHz, N-Connect female
6GK5 795-6DC00-0AA0
ANT795-6MN
Omni antenna, mounted on
roof/vehicle, 6/8 dBi 2.4 GHz and 5
GHz, N-Connect female
6GK5 795-6MN10-0AA6
ANT795-6MT
Omni antenna (MIMO), mounted on 6GK5 795-6MT00-0AA0
roof/vehicle/ceiling, 5/7 dBi 2.4
GHz and 5 GHz, 3 x QMA connector female
ANT793-8DL
Directional antenna verticalhorizontal polarized, 5 GHz, 14dBi,
IP66, 2xN-Connect female
6GK5 793-8DL00-0AA0
ANT793-8DP
Directional antenna, mast/wall
mounting, 13 / 13.5 dBi 4.9 GHz
and 5 GHz, N-Connect female
6GK5 793-8DP00-0AA0
ANT795-4MX
Omnidirectional antenna, 2/2,5 dBi, 6GK5 795-4MX00-0AA0
2.4 GHz and 5 GHz, IP69K, NConnect male
ANT795-6MP
Omnidirectional antenna, 5/7 dBi,
2.4 GHz and 5 GHz, IP65/67, NConnect female
6GK5 795-6MP00-0AA0
ANT896-6MM
Omnidirectional antenna for mobile
wireless, WLAN and GPS, WLAN:
6/7 dBi, 2.4 GHz and 5 GHz, IP68,
IP69 K, QMA-Connect female, port
2
6GK5 896-6MM00-0AA0
IWLAN RCoax Cable
2,4 GHz PE 1/2"
Omni antenna, 0 dBi 2.400 - 2.485
GHz, N-Connect female.
6XV1875-2A
IWLAN RCoax Cable 5
GHz PE 1/2"
Omni antenna, 0 dBi 5.150 – 5.875
GHz, N-Connect female.
6XV1875-2D
SCALANCE W788C-2
20
Operating Instructions, 01/2017, A5E03692120-11
Description
3.4 Accessories
NOTICE
ANT795-4MA
The ANT795-4MA antenna has degree of protection IP30 and is therefore only suitable for
dry environments.
Note
ANT793-8DJ
The antenna ANT793-8DJ may only be used with the flexible connecting cable 6XV18755CH50 (5 m length) or 6XV1875-5CN10 (10 m length). Other flexible connecting cables are
not permitted.
Notice for USA/Canada
Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2).
Note
ANT793-8DK
The antenna ANT793-8DK may only be used with the flexible connecting cable 6XV18755CN10 (10 m length). Other flexible connecting cables are not permitted.
Notice for USA/Canada
Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2).
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
21
Description
3.5 LED display
3.5
LED display
Information on operating status and data transfer
On the front of the housing, several LEDs provide information on the operating status of the
SCALANCE W7x8:
LEDs with RJ-45 variants
LEDs with M12 variants
LED display of the SCALANCE W788C-2. You will find information on the significance of the
individual elements in the documentation for the WLC700.
SCALANCE W788C-2
22
Operating Instructions, 01/2017, A5E03692120-11
4
Mounting
CAUTION
Minimum distance to antennas
Fit the device so that there is a minimum clearance of 20 cm between antennas and
persons.
WARNING
If a device is operated in an ambient temperature of more than 50 °C, the temperature of
the device housing may be higher than 70 °C. The device must therefore be installed so
that it is only accessible to service personnel or users that are aware of the reason for
restricted access and the required safety measures at an ambient temperature higher than
50 °C.
WARNING
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
General notes on use according to ATEX and IECEx
WARNING
To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this
enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN
60529.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
23
Mounting
4.1 Securing the housing
4.1
Securing the housing
Grounding connector
WARNING
Operation of the W7x8 only with connected grounding cable
To operate the SCALANCE W7x8 safely, the housing must make contact with a grounding
cable. Do not use the SCALANCE W7x8 without a grounding cable connected.
The grounding cable is fixed to the housing with a screw. On the rear of the device there is
an M4 threaded hole for this purpose, seeDrilling pattern (Page 25).
Mount the grounding cable before you mount the device
Installation options
To install the W7x8, you have the following options:
● Wall mounting
● Installing on the S7-300 standard rail
● Installing on a DIN rail
CAUTION
Danger of injury by falling objects
If the SCALANCE W7x8 is subjected to strong vibration (> 10 g), mounting on a 35 mm DIN
rail does not provide adequate support. Under such conditions, the device can come out of
the mounting and may cause injury.
In this case, install the device on an S7-300 standard rail or on a wall.
Installation location
There are no restrictions regarding the installation location for the device. Antennas, in
particular directional antennas, must be mounted according to their characteristics.
Note
- If you are installing outdoors, use the SCALANCE W786.
- The minimum distance to fluorescent lamps should be 0.5 m.
- When installed in a cabinet, we recommend that you do not install relays on the same or on
directly neighboring mounting rails.
SCALANCE W788C-2
24
Operating Instructions, 01/2017, A5E03692120-11
Mounting
4.2 Wall mounting
4.2
Wall mounting
Use the holes in the housing to screw the device to the wall or on a horizontal surface. The
location of the holes can be seen in the following figure:
Figure 4-1
①
Drilling pattern (dimensions in mm)
Ground connector (thread M4)
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
25
Mounting
4.3 Installing on the S7-300 standard rail
4.3
Installing on the S7-300 standard rail
Follow the steps below to install the SCALANCE W7x8 on a vertical S7-300 rail:
1. Place the device on the upper edge of the S7-300 standard rail (position A).
2. Screw the device to the rail using the supplied screw (position B).
Figure 4-2
Installing on an S7-300 standard rail
SCALANCE W788C-2
26
Operating Instructions, 01/2017, A5E03692120-11
Mounting
4.4 Installing on a DIN rail
4.4
Installing on a DIN rail
The SCALANCE W7x8 is suitable for rail mounting on 35 mm DIN EN 50022 rails.
Bracket for DIN rail mounting
Note
The bracket for installation on a DIN rail does not ship with the product, seeAccessories
(Page 15).
The bracket consists of the following parts:
● 1 DIN rail slider
● 1 spring
● 2 screws
Mount the bracket on the rear of the device as shown in the figure below:
Figure 4-3
Fitting the DIN rail slider
Installing on the DIN rail
The following figure shows the W7x8 mounted on a DIN rail. Follow the steps outlined below:
1. Place the device on the upper edge of the DIN rail (position A).
2. Pull the spring-mounted DIN rail slider (position B) down and press the device against the
DIN rail until it locks in place.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
27
Mounting
4.4 Installing on a DIN rail
Figure 4-4
Installing on a DIN rail
SCALANCE W788C-2
28
Operating Instructions, 01/2017, A5E03692120-11
5
Connection
5.1
Safety when connecting up
Safety notices
When connecting up the device, keep to the safety notices listed below.
WARNING
EXPLOSION HAZARD
Replacing components may impair suitability for Class 1, Division 2 or Zone 2.
WARNING
EXPLOSION HAZARD
Do not open the device when the supply voltage is turned on.
Note
Close unused sockets
Close all unused M12 sockets with protective caps (torque at least 0.4 Nm) to achieve the
specified type of protection.
Note
Strain relief of the interfaces
To prevent weights or mechanical movement that can affect an interface causing interrupted
contact, fix the cables to a cable guide or rail at short intervals.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
29
Connection
5.2 Lightning protection, power supply and grounding
5.2
Lightning protection, power supply and grounding
Lightning protection
WARNING
Danger due to lightning strikes
Antennas installed outdoors must be within the area covered by a lightning protection
system. Make sure that all conducting systems entering from outdoors can be protected by
a lightning protection potential equalization system.
When implementing your lightning protection concept, make sure you adhere to the VDE
0182 or IEC 62305 standard.
Suitable lightning protectors are available in the accessories of SIMATIC NET Industrial
WLAN.
Note
We recommend that you use the maintenance-free lightning protector LP798-2N.
Exception: When there is also DC power supplied via the antenna cable. In this case, only
the lightning protector LP798-1N can be used.
WARNING
Danger due to lightning strikes
Installing this lightning protector between an antenna and a SCALANCE W700 is not
adequate protection against a lightning strike. The LP798-1N lightening protector only
works within the framework of a comprehensive lightning protection concept. If you have
questions, ask a qualified specialist company.
Note
The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only
when a Blitzductor is used with 24 VDC:
BVT AVD 24
type No. 918 422
manufacturer: DEHN+SÖHNE GmbH+Co.KG, Hans Dehn Str. 1, Postfach 1640, D 92306 Neumarkt, Germany
SCALANCE W788C-2
30
Operating Instructions, 01/2017, A5E03692120-11
Connection
5.2 Lightning protection, power supply and grounding
Supply voltage
WARNING
Safety extra low voltage
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 / EN
60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power
supply unit for the equipment power supply must comply with NEC Class 2, as described by
the National Electrical Code (r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
WARNING
Transient overvoltages
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
31
Connection
5.2 Lightning protection, power supply and grounding
Grounding
WARNING
Danger to life from overvoltage, fire hazard
When using outdoor antennas, the shared or even grounded pin of the circuit must be
connected to the shield of the coaxial cable and with all touchable conductive parts and
circuits. Otherwise, in the event of a fault there may be illegally high voltages on touchable
parts.
NOTICE
Damage to the device due to potential differences
To fully eliminate the influence of electromagnetic interference, the device must be
grounded. There must be no potential difference between the following parts, otherwise the
device or other connected device could be severely damaged:
• Housing of the SCALANCE W700 and the ground potential of the antenna.
• Housing of the SCALANCE W700 and the ground potential of a device connected over
Ethernet.
• Housing of the SCALANCE W700 and the shield contact of the connected Ethernet
cable.
Connect both grounds to the same foundation earth or use an equipotential bonding cable.
WARNING
EXPLOSION HAZARD
Do not connect or disconnect cables to or from the device when a flammable or
combustible atmosphere is present.
General notes on use in hazardous areas according to UL-HazLoc
WARNING
EXPLOSION HAZARD
Do not connect or disconnect while the circuit is live or unless the area is known to be free
of ignitible concentrations.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations
only.
SCALANCE W788C-2
32
Operating Instructions, 01/2017, A5E03692120-11
Connection
5.3 Power supply and Ethernet
5.3
Power supply and Ethernet
Connecting the power supply
Models RJ-45 / degree of protection IP30
The four-pin connecting socket has the following pin assignment:
Pin
Signal
Description
1
L1+
24 VDC
2
M1
Ground
3
M2
Ground
4
L2+
24 VDC
The M12 socket for the power supply has the following pin assignment:
Pin
Signal
Description
1
L1
24 VDC
-
-
-
3
M1
Ground
-
-
-
Power over Ethernet (PoE)
With the SCALANCE W7x8, power supply using Power over Ethernet (PoE) is also possible.
The devices support the standards 802.3at type 1 (IEEE 802.3af ) and IEEE 803.at type 2.
● Gigabit Ethernet
When you connect to gigabit Ethernet, the power supply is a phantom power supply over
data wires 1, 2, 3 and 6. This corresponds to alternative A according to IEEE 802.3af.
● Fast Ethernet
On an 8-wire Fast Ethernet cable, the power is supplied via the free data wires 4, 5, 7
and 8. This corresponds to alternative B according to IEEE 802.3af.
Note
Disabling the PoE power supply
Before you pull a plug via which the device is supplied with power using PoE, disable the
relevant PoE power supply.
Note
No power sourcing equipment (PSE)
The W7x8 cannot be used as a PoE power supply for other devices.
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
33
Connection
5.3 Power supply and Ethernet
Note
Grounding connector
The device has a grounding connector on the back of the device (screw M4), see position ①
in the drilling pattern (Page 25). Connect the grounding cable before you mount the device.
Refer to the information in the section Mounting (Page 23).
Ethernet connector
Depending on the model, the connection of the SCALANCE W7x8 to Ethernet is either via
an RJ-45 interface or via an M12 interface.
SCALANCE W788C-2
34
Operating Instructions, 01/2017, A5E03692120-11
Connection
5.4 Antenna connectors
5.4
Antenna connectors
Note
Tightening torque
The following tightening torques apply to the connectors:
• with N-Connect connectors: 1.7 Nm
• with SMA/R-SMA connectors: 1 Nm
R-SMA for degree of protection IP30
The SCALANCE W788C-2 RJ-45 has antenna sockets of the type R-SMA, 3 on the top and
3 on the underside of the device.
①
②
③
④
⑤
⑥
R1A1
R1A2
R1A3
R2A1
R2A2
R2A3
Figure 5-1
Antenna connector IP30
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
35
Connection
5.4 Antenna connectors
N-Connect for degree of protection IP65
The SCALANCE W788C-2 M12 has antenna sockets of the type N-Connect, 3 on the top
and 3 on the underside of the device.
Note
Cabinet installation
When installing the SCALANCE W7x8 in a cabinet, you need to use detached antennas. A
suitable flexible connecting cable for a connection between SCALANCE W778/W738 and a
detached antenna are available from SIMATIC NET. You will find detailed information in the
section Accessories.
Note
Terminating resistor
Each WLAN interface has three antenna connectors. Connectors that are not used must
have a terminating resistor fitted, see Accessories.
The antennas R1A1 and R2A1 must be always be connected as soon as the associated
WLAN Interface is turned on. if no antenna is connected, the relevant interface must also be
disabled for RX and TX. Otherwise, there may be transmission disruptions.
You will find information on the configuration of the antennas in the following documents:
• SCALANCE W7x8
SCALANCE W700 configuration manual, section "Configuring antennas"
• SCALANCE W7x8C
SCALANCE WLC711 User Guide, section "Configuring wireless AP radio properties"
SCALANCE W788C-2
36
Operating Instructions, 01/2017, A5E03692120-11
Connection
5.4 Antenna connectors
①
②
③
④
⑤
⑥
R1A1
R1A2
R1A3
R2A1
R2A2
R2A3
Figure 5-2
Antenna connector IP65
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
37
Connection
5.4 Antenna connectors
SCALANCE W788C-2
38
Operating Instructions, 01/2017, A5E03692120-11
6
Technical data
6.1
Technical specifications of the SCALANCE W788C-2)
The following technical specifications apply to the following devices:
● SCALANCE W788C-2 RJ45
● SCALANCE W788C-2 M12
● SCALANCE W788C-2 M12 EEC
Note
Bridging a power outage is possible only with an input voltage of 24 VDC (-15% to +20%).
Note
You will find detailed information on the transmit power and receiver sensitivity in the
document "Leistungsdaten 802.11abgn PCIe Minicard / Characteristics 802.11abgn PCIe
Minicard" (REF_W700-RadioInterface.pdf).
Technical specifications
Data transfer
Ethernet transfer rate
10 / 100 / 1000 Mbps
Wireless transmission rate
1 ... 450 Mbps
Wireless standards supported
IEEE 802.11a
IEEE 802.11b
IEEE 802.11g
IEEE 802.11h
IEEE 802.11n
Power supply standards supported
Type
IEEE 802.3at type 1 (802.3af)
IEEE 802.3at type 2 (Power over Ethernet)
Class
Class 4
Quantity
1
Design
RJ-45 jack
Properties
Half duplex/full duplex, autocrossover,
autonegotiation, autosensing, PoE, floating
Quantity
1
Design
M12 socket
Properties
Half duplex/full duplex, autocrossover,
autonegotiation, autosensing, PoE, floating
Attachment to Industrial Ethernet
RJ-45 variants
M12 variants
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
39
Technical data
6.1 Technical specifications of the SCALANCE W788C-2)
Technical specifications
Permitted cable lengths (Ethernet)
(Alternative combinations per length range)
IE TP torsion cable
0 ... 55 m
0 ... 45 m + 10 m TP cord
IE FC TP marine cable
0 ... 85 m
IE FC TP trailing cable
0 ... 75 m + 10 m TP cord
IE FC TP flexible cable
IE FC TP FRNC cable
IE FC TP festoon cable
IE FC TP food cable
IE FC TP standard cable
0 ... 100 m
0 ... 90 m + 10 m TP cord
Wireless interface
IWLAN interface
Quantity
2
Antenna connector
Quantity
6
Design
•
RJ-45 variants
•
R-SMA female
•
M12 variants
•
N Connect, female
Impedance
Frequency range
50 Ω nominal
2412 ... 2480 MHz
4920 ... 5875 MHz
Electrical data
Power supply
Direct 24 VDC supply
•
Supply voltage from terminal
block/socket
•
Permitted range
•
•
–
Non EEC variants
–
EEC variants
•
24 VDC Safe Extra Low Voltage (SELV)
–
19.2 to 28.8 VDC
–
16.8... 31.2 VDC (UL approvals only
valid for 19.2 ... 28.8 VDC)
–
Terminal block, 4 terminals
–
M12 connectors
Design
–
RJ-45 variants
–
M12 variants
Properties
•
Not electrically isolated
Supply voltage from PoE
•
Supply voltage from terminal
block/socket
•
48 VDC
•
Permitted range
•
36 to 57 VDC
•
Design
•
Via RJ-45 jacks
•
Properties
•
Electrically isolating
Corresponding to IEEE802.3at
Insulation resistance > 2 MOhms
SCALANCE W788C-2
40
Operating Instructions, 01/2017, A5E03692120-11
Technical data
6.1 Technical specifications of the SCALANCE W788C-2)
Technical specifications
Fusing
2.5 A / 24 VDC
1 A / 48 VDC PoE
Current consumption
At 24 VDC / max.
650 mA
Effective power loss
At 24 VDC / max.
15.6 W
At 24 VDC / typical
15 W
Quantity
1
Design
Terminal block, 2 terminals
Status "0"
13 ... 30 VDC
Status "1"
-30 to 3 VDC
Max. input current
8 mA
Max. cable length
30 m
Properties
Inputs isolated from electronics.
During operation
-20 ℃ to +60 °C
During storage
-40 ℃ to +70 °C
During transportation
-40 °C to +70 °C
Relative humidity
During operation
≤ 95% at 25 °C, no condensation
Operating altitude
During operation
≤ 2,000 m above sea level at max. 60 °C
ambient temperature
Contaminant concentration
According to IEC 60721
Digital input
Permitted ambient conditions
Ambient temperature
Design, dimensions and weight
Degree of protection
•
RJ-45 variants
•
IP30
•
M12 variants
•
IP65
Weight
1.7 kg
Dimensions (W x H x D)
•
RJ-45 variants
•
158 x 200 x 79 mm
•
M12 variants
•
175.2 x 200 x 79 mm
Installation options
•
Wall mounting
• Mounting on an S7-1500 standard rail
With additional holding plate
•
Mast mounting
•
Mounting on a DIN rail
•
Mounting on an S7-300 standard rail
Mean time between failure (MTBF)
At 40 °C ambient temperature
41 years
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
41
Technical data
6.1 Technical specifications of the SCALANCE W788C-2)
SCALANCE W788C-2
42
Operating Instructions, 01/2017, A5E03692120-11
Dimension drawings
7
The following dimensions are specified in mm.
Dimension drawing of the SCALANCE W7x8-2 RJ45 (degree of protection IP30)
Figure 7-1
Front view RJ-45
Figure 7-2
View from above RJ-45
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
43
Dimension drawings
Dimension drawing of the SCALANCE W7x8-2 M12 (degree of protection IP65)
Figure 7-3
Front view M12
Figure 7-4
View from above M12
SCALANCE W788C-2
44
Operating Instructions, 01/2017, A5E03692120-11
8
Approvals
You will find the approvals of the products in the reference work "Approvals SCALANCE
W700 802.11n" on the Internet pages of Siemens Industry Online Support:
● Using the search function:
support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en)
Enter the entry ID of the relevant manual as the search item.
● In the navigation panel on the left-hand side in the area "Industrial Communication":
Industrial communication
(http://support.automation.siemens.com/WW/view/en/10805878/133300)
Go to the required product group and make the following settings:
"Entry list" tab, Entry type "Manuals / Operating Instructions"
You will find the documentation for the SIMATIC NET products relevant here on the data
storage medium that ships with some products:
● Product CD / product DVD
● SIMATIC NET Manual Collection
● SIMATIC NET IWLAN CD
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
45
Approvals
SCALANCE W788C-2
46
Operating Instructions, 01/2017, A5E03692120-11
Index
A
S
Antenna cables, 18
Antennas, 18
Article numbers, 5
Safety extra low voltage, 30, 31
Safety notices
Use in hazardous areas, 29
when connecting up, 29
Scope of delivery, 14
SELV, 30
Supply voltage, 31
C
Cables
Permitted lengths, 39
Connectors, 14
D
T
Technical specifications, 39, 39
Type designations, 13
Dimension drawings, 43
Documentation on the CD, 5
E
Ethernet, 33
G
Grounding, 30, 32
I
Installation
DIN rail, 27
S7-300 standard rail, 26
Wall mounting, 25
Interfaces, 39
L
LED display, 22
Lightning protection, 30
P
Power supply, 33
Protective caps, 14
SCALANCE W788C-2
Operating Instructions, 01/2017, A5E03692120-11
47
Index
SCALANCE W788C-2
48
Operating Instructions, 01/2017, A5E03692120-11
Was this manual useful for you? yes no