Installation and Operation Instructions Outdoor Vent-Free Gas Fireplace With Refractory Panels P/N 127042-01 REV. E 01/2017 Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 127042-02. PFS C Models ® US Report No. F09-026 VRE3036ZMN VRE3036ZMP VRE3042ZMN VRE3042ZMP P127042-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Installateur : Laissez cette notice avec l’appareil. Consommateur : Conservez cette notice pour consultation ultérieure. WHEN USED AS AN OUTDOOR APPLIANCE DANGER CARBON MONOXIDE WARNING This appliance can produce carbon monoxide which has no odor. • Using it in an enclosed space can kill you. • Never use this appliance in an enclosed space such as a camper, tent, car or home. WARNING: For Outdoor Use Only. • DANGER IF YOU SMELL GAS: 1. Shut off gas to appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department. WARNING: Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. AVERTISSEMENT: RISQUED’INDENDIE OU D’EXPLOSION Le non-respect Des avertissements de sécurité pourrait d’entraîner des blessures graves, la mort ou des dommages matériels. - Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil. - QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ: • Ne pas tenter d’allumer d’appareil. • Ne touchez à aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous trouvez. • Sortez immédiatement de bâtiment. • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindies. - L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. Thank you for your purchase. We appreciate your business! TABLE OF CONTENTS Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace. Please read and understand these instructions before installing or operating. Safety ............................................................................................. 2 Local Codes ................................................................................... 4 Requirements for the Commonwealth of Massachusetts ..............4 Product Features ............................................................................ 4 Locating Fireplace .......................................................................... 4 Product Specifications ................................................................... 5 Installation ..................................................................................... 6 Operation .................................................................................... 12 Inspecting Burners ....................................................................... 13 Cleaning and Maintenance ........................................................... 14 Safety Device ............................................................................... 14 Specifications............................................................................... 15 Wiring Diagram ............................................................................ 15 Service Hints ................................................................................ 19 Technical Service ......................................................................... 19 Replacement Parts ....................................................................... 19 Troubleshooting ........................................................................... 16 Parts ............................................................................................ 20 Accessories .................................................................................. 24 Warranty ...................................................................................... 27 SAFETY WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. WARNING: Fireplace must be operated only with doors fully open. WARNING: This product contains and/or generates chemicals known to the state of California to cause cancer or birth defects or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning. DANGER: Carbon monoxide poisoning may lead to death! 2 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Any change to this heater or its controls can be dangerous. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the fireplace. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of live SuperiorFireplaces.US.com 127042-01E SAFETY Continued Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room with the appliance. Fireplace front and screen become very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. Carefully supervise young children when they are in the area of the fireplace. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote. You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running heater. The finish of the front face is protected with a self adhering plastic coating that must be removed before fireplace is operated. To prevent melting, ensure that the plastic coating protecting the finish is removed. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 127042-01E 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only). 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the fire department 4. This fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building, garage or any other enclosed area. 5. Do not use this fireplace as a wood burning fireplace. Use only the logs provided with the fireplace. Do not burn solid fuels in this fireplace. 6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. 7. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, Page 14. 8. Before using furniture polish, wax, carpet cleaner or similar products, turn fireplace off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 9. Do not run fireplace • where flammable liquids or vapors are used or stored • under dusty conditions 10. Do not use this fireplace to cook food or burn paper or other objects. 11. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 12. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger). 13. Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace. 14. Operating fireplace above elevations of 4,500 feet could cause pilot outage. 15. Provide adequate clearance around air openings. SuperiorFireplaces.US.com 3 LOCAL CODES PRODUCT FEATURES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, CSA B149.2, as applicable. *Available from: American National Standards Institute, Inc. 25 West 43rd Street, 4th floor New York, NY 10036 National Fire Protection Association, Inc. 1 Batterymarch Park Quincy, MA 02169-7471 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts if the following additional requirements are met: • Un-vented Room Heaters shall be installed in accordance with 527 CMR 30. • Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T-handle type valve. • Unvented appliances may NOT be installed in bedrooms or bathrooms. • A working smoke detector must be installed in the area where vent-free appliances are installed. Seller of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. 4 REFRACTORY BRICK LINER Your fireplace features a concrete refractory brick liner. As with all concrete liners, this liner may develop slight cracks when exposed to heat. These cracks will not affect the performance of the fireplace. LOCATING FIREPLACE PLANNING Plan where you will install the fireplace. This will save time and money later when you install the fireplace. Before installation, consider the following: 1. Where the fireplace will be located. Allow for wall and ceiling clearances (see Installation Clearances, Page 6). 2. Everything needed to complete installation. 3. These models are for outdoor use only. 4. Proper air for combustion and ventilation. SuperiorFireplaces.US.com 127042-01E PRODUCT SPECIFICATIONS 36" AND 42" MODELS NOTE: If only one dimension is shown, the dimension is the same for both 36" and 42" models. Fireplace Top View 29" (737 mm) 36" Models 36" (915 mm) 42" Models 4" (102 mm) Left Side View 5 9-1/4" (235 mm) 13-1/2" (343 mm) 41" (1042 mm) 36" Models 48" (1220 mm) 42" Models 3-1/2" (89 mm) /8" (16 mm) 43" (1093 mm) 36" Models 50" (1270 mm) 42" Models Right Side View 35" (889 mm) 36" Models 42" (1067 mm) 42" Models 41" (1042 mm) 36" Models 45" (1143 mm) 42" Models 21" (534 mm) 36" Models 24" (610 mm) 42" Models 37" (940 mm) 36" Models 41" (1042 mm) 42" Models 21" (534 mm) 36" Models 23" (584 mm) 42" Models 9-1/4" (235 mm) Electrical Access Hole 1 3- /2" (89 mm) 13-1/2" (343 mm) 4-1/2" (115 mm) Front View 10-1/2" (267 mm) 36" Models 10-1/4" (261 mm) 42" Models 14-1/2" (369 mm) 36" Models 16-1/2" (420 mm) 42" Models Figure 1 - Fireplace Dimensions (36" and 42" Models) 127042-01E SuperiorFireplaces.US.com 5 INSTALLATION IMPORTANT: Make sure fireplace is level. If fireplace is not level, log set will not work properly. Use dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, Page 7). INSTALLATION CLEARANCES WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall. Carefully follow these instructions. This will ensure safe installation. Fireplace hood must be used if combustible mantel material is installed. Minimum Wall and Ceiling Clearances (see Figure 2) A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 2. Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3-1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 2). B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42". C. When fireplace is installed on carpeting, tile (vinyl) or other combustible material, other than wood flooring, fireplace should be installed on a metal or wood panel extending the full width and depth of enclosure. D. Clearances from bottom of fireplace to the floor is 0". OUTDOOR ENCLOSURE REQUIREMENTS Must conform to one of the following conditions: • With walls on all sides, but with no overhead cover; • Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in breezeway or at right angles to each side; or • Within a partial enclosure which includes an overhead cover and three sidewalls, as long as 30% or more of the horizontal periphery of the enclosure is permanently open. CAUTION: Do not install the fireplace directly on carpet or vinyl. WARNING: Fireplace hood must be used if a combustible mantel material is installed. Mantel Clearances for Built-In Installation If placing custom mantel above built-in fireplace, you must meet the minimum allowable clearance between mantel shelf and top of fireplace opening shown in Figure 3, Page 6. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel. NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the fireplace may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual. Example Facing material above firebox must be of noncombustible material. A 12" (305 mm) concrete board projecting the width of the fireplace is supplied. Mantel Shelf Note: Any portion of the mantel shelf must NOT extend beyond this profile. C B * 12" (305 mm) Min. Framing Material *Minimum 16" from Side Wall Figure 2 - Minimum Clearance for Combustible to Wall Firebox Wire-mesh Screen A D E F Noncombustible Material May Project Off this Surface above the Firebox Hood Hood MUST be used if a combustible mantel is installed. Note: All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf. A B C D E F Minimum Mantel Clearances 1-1/2" (39 mm) 6-3/4" (172 mm) 12" (305 mm) 12" (305 mm) 16" (407 mm) 20" (508 mm) Figure 3 - Minimum Mantel Clearances for Built-In Installation 6 SuperiorFireplaces.US.com 127042-01E INSTALLATION Continued Steel Stud or Steel Framing Required. NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following: • raise the mantel to an acceptable height • remove the mantel 12" (305 mm)min. noncombustible wall board or facing material above fireplace. BUILT-IN FIREPLACE INSTALLATION 1. Frame in rough opening. The fireplace framing must be constructed of steel stud material. Steel studs are provided and are permanently fixed amount the perimeter of the unit. Use dimensions in Table 1 and rough opening layout in Figure 4a. Adjust framing so that fireplace is flush with finished wall surface. If installing in a corner, use dimensions in Figures 4b and 4c for rough opening. 2. Install gas piping to fireplace location (see Connecting to Gas Supply, Page 9). 3. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 4. Carefully insert fireplace into rough opening. Table 1 Rough Opening Dimensions for Built-in Installation Front Width Model (Inside to Inside) Height Depth (Min.) 36" 44" (1118 mm) 42 3/4" (1086 mm) 21" (534 mm) 42" 51" (1296 mm) 46 1/2" (1182 mm) 23" (585 mm) Depth (Minimum) Combustible materials not allowed adjacent to fireplace. 12" (305 mm) min. noncombustible wall board or facing materials on sides. Figure 5 - Installing Firebox INSTALLING DRAIN PAN DP36/DP42 The fireplace enclosure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under fireplace within fireplace enclosure (see Accessories, Page 24). INSTALLING FIREPLACE SCREEN 1. Insert each rod through all rings located at top of screen. 2. Insert first rod into rear hole in left side of fireplace. Fasten rod to rear hole near center of fireplace using #10 x 3/8" Phillips screw provided (see Figure 6). 3. Insert other rod into front hole on right side of fireplace and fasten using remaining Phillips screw. Figure 4a Height Identification Label Location Top View of Rod Layout Width (Inside to Inside) Rear Hole Front Hole FOR 36" MODELS 52" (1321 mm) 37" (940 mm) Figure 4b 44" (1118 mm) 45° 74" (1880 mm) Rod TOP VIEW Ring FOR 42" MODELS 61" (1550 mm) Figure 4c 43" (1093 mm) 51" (1296 mm) Screen 45° Screw 86" (2185 mm) TOP VIEW Figure 4 - Rough Opening for Installing in Wall 127042-01E SuperiorFireplaces.US.com Figure 6 - Installing Fireplace Screen 7 INSTALLATION Continued Spring Clip INSTALLING FIREPLACE HOOD HS36/HS42 1. 2. 3. 4. Remove protective film from stainless hood. Align three mounting holes located on back side of hood with front face of fireplace (see Figure 7). Mounting holes should be at least 2" up from edge of fireplace opening. Hold fireplace hood in place. Using a 1/8" (0.125 dia.) drill bit, drill through 3 mounting holes. Insert 3 screws through mounting holes in hood into holes in fireplace. Fold Door and Slide Top Pins into Track Pivot Plate or Pivot Hole Mounting Holes on Hood Insert Pin into Spring Clip Insert Bottom Pivot Pin into Pivot Plate or Hole and Swing Door into a Vertical Position Figure 8: Installing Bi-Fold Glass Door WARNING: Fireplace must be operated only with doors fully opened. Screws Figure 7 - Installing Hood INSTALLING BI-FOLD GLASS DOORS IMPORTANT: Use only glass doors certified for use with this fireplace (See Accessories, Page 24). Door Installation Pivot and spring clips have been installed and pretested at the factory, but some readjustments may be needed due to movement during shipping or handling. Install doors using the following steps. If you find doors do not close properly or do not appear level or straight, proceed with section on door adjustment. 1. With bi-fold door completely folded, insert bottom pivot pin into pivot plate or pivot hole located near bottom corner of front face opening and swing door to the vertical position making sure top pins slide into door track. Door is installed when top door pin snaps into spring clip (see Figure 8). 2. Repeat step 1 for remaining door. 8 Door Adjustment Remove doors and slightly loosen lower pivot plate (if equipped) and upper spring clips. Replace doors and fully close them. Use 1/8" shims (any material) to level doors. Once the proper setting is achieved, carefully open doors enough so that you can access pivot and spring clips with a Phillips screwdriver. Tighten screws (see Figure 9, Page 9). Please read the following care and operation guidelines before operating your appliance or fireplace. • Glass doors should be operated in the fully open position only (see Figure 10, Page 9). • If doors are not fully open, the thermo disk will automatically turn off burner. See Safety Device on Page 15 for instructions on how to reset the thermo disk. • When operating doors, do not slam shut or abuse them. • Always keep area below bottom edge of doors clear from obstacles or debris. • Do not operate this appliance if glass doors are broken or damaged. • Do not use abrasive liquids or cleaners for cleaning of glass and door trims. Any household glass cleaner should suffice. Do not clean doors when hot, allow the appliance to cool before cleaning. SuperiorFireplaces.US.com 127042-01E INSTALLATION Continued Spring Clip CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. Partially Opened Door WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the control valve. Figure 9: Door Adjustment CAUTION: Never connect propane/LP unit directly to the propane/LP supply. This unit requires an external regulator (not supplied). Install the external regulator between the unit and the propane/LP supply. WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas. Installation Items Needed N PE YO LL FU Figure 10: Bi-Fold Doors Fully Open Before installing heater, make sure you have the items listed below. • approved flexible gas hose and fittings (supplied with appliance, if allowed by local codes) • external regulator (propane/LP models only) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve* • test gauge connection* • sediment trap • tee joint • pipe wrench * An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer. For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, control valve damage could occur. Install external regulator with the vent pointing down as shown in Figure 11. Pointing the vent down protects it from freezing rain or sleet. Propane/LP Supply Tank External Regulator Vent Pointing Down Figure 11 - External Regulator with Vent Pointing Down 127042-01E SuperiorFireplaces.US.com 9 INSTALLATION Continued REMOTE PROPANE/LP GAS SUPPLIES AND ENCLOSURES If appliance is to be permanently connected to a gas piping system from a remote supply tank, installation must be in accordance with local codes or, in absence of local codes, with the National Fuel Gas Codes ANSI Z223.1/NFPA 54. Enclosures may be used to conceal propane/LP supply tanks and must be constructed to meet the following minimum construction requirements: • An enclosure must have either one open side or at least four opposing vent openings, top and bottom, which meet minimum requirements for size and location (see Figure 12). • Each opening must provide a minimum or 1/2 square inches (3,23 cm2) of open area for each pound propane/LP contained in enclosed supply tank. Example: A full enclosure for a 20 pound propane/LP tank must have at least four, 10 square inches (65 cm2) openings [a 2" x 5" (5 x 13 cm) square]. • The top openings must be 180° opposing and be placed at valve level. • The bottom openings must be 180° opposing and be placed 5" (12.7 cm) above bottom floor. • There must be 2" (5 cm) minimum clearance from the floor to ground level of enclosure. CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur. Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 13). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas. Minimum of 5" (12.7 cm) From Floor To Top Of Bottom Opening Top Openings At Valve Level 2 Openings Top and Bottom on Each Side Minimum 0.5 inch2 (3.23 cm2) of Free Air Space For Each Pound of Fuel But No Less Than 10 inches2 (65 cm2) Total Minimum of 2" (5 cm) From Floor Bottom To Ground Level Minimum 1/8" (0.3 cm) Permissible Openings Figure 12 - Propane/LP Tank Enclosure We recommend that you install a sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and appliance. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly. CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings. Equipment Shutoff Valve with 1/8" NPT Tap* Approved Flexible Gas Hose (If allowed by local codes) Natural From Gas Meter (5" W.C.** to 10.5" W.C. Pressure) 3" (77 mm) Min. Propane/LP Pipe Cap Tee From External Nipple Joint Regulator (11" W.C.** to 14" Sediment Trap W.C. Pressure) * Purchase the optional shutoff valve from your dealer. ** Minimum inlet pressure for purpose of input adjustment. Figure 13 - Gas Connection 10 SuperiorFireplaces.US.com 127042-01E INSTALLATION Continued CHECKING GAS CONNECTIONS Open WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. Equipment Shutoff Valve Closed WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. CAUTION: Make sure external regulator has been installed between propane/LP supply and appliance. See guidelines under Connecting to Gas Supply, Page 9. PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage control valve. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) Figure 14 - Equipment Shutoff Valve Pressure Testing Appliance Gas Connections 1. Open equipment shutoff valve (see Figure 14). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of appliance is in the OFF position. 4. Check all joints from equipment shutoff valve to gas control (see Figure 15 or 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light appliance (see Operation, Page 12) Check all other internal joints for leaks. 7. Turn off appliance. Propane/LP Supply Tank Control Valve Location Figure 15 - Checking Gas Joints (Propane/LP Gas Only) The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). 1. Close equipment shutoff valve (see Figure 14). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 15 or 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once. Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Control Valve Location Figure 16 - Checking Gas Joints (Natural Gas Only) 127042-01E SuperiorFireplaces.US.com 11 INSTALLATION Continued OPERATION PLACEMENT OF LOOSE EMBERS FOR YOUR SAFETY READ BEFORE LIGHTING CAUTION: Do not place any loose embers around pilot assembly. Two bags of loose embers are provided with this unit. For this installation use the embers that are approximately 1" square in size. If needed, larger embers can be broken to size. These embers aid in concealing the burner pan, directing flames through the ember bed, quiet operation of the unit and gives a natural random flame pattern. Place embers as follows: 1. Place embers around center ember bed or ember pod. 2. Place individual embers on their edge (not flat) along the top of burner pan. This aids in directing flames from the burner through ember bed. NOTE: Too many embers or embers placed flat along burner pan can suppress the flames. 3. When unit is lit, check flames for random appearance and ember bed glowing red-orange in color (see Burner and Pilot Flame Pattern, Page 13). If this is not happening, either add, remove or reposition loose embers. IMPORTANT: Turn unit off and let cool before repositioning loose embers. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted with a piezo igniter. When lightning the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified technician. Force or attempted repair may result in a fire. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS Figure 17 - Placement of Embers 1. 2. 3. 4. 5. 6. 7. 8. 12 STOP! Read the safety information, above. Make sure switch is in the OFF position. Be sure gas line shut-off valve is OPEN. Press in and turn control knob clockwise to the OFF position (see Figure 18, Page 13). NOTE: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. DO NOT FORCE. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information in column 1. If you don't smell gas, go on the next step. Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 18, Page 13). With control knob pressed in, press and release igniter button. This will light pilot. If needed, keep pressing igniter button until pilot lights. NOTE: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, turn off gas supply and contact a qualified service person or gas supplier for repairs. SuperiorFireplaces.US.com 127042-01E INSPECTING BURNERS OPERATION Continued NOTE: If pilot goes out, repeat steps 4 through 8. 9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and move switch to the ON position to light burner. NOTE: AUTO is only functional when using optional remote control accessory. 11. Set flame adjustment knob to any level between HI and LO. Control Knob Piezo Igniter Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary. The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 20. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile. If you pilot assembly does not meet these requirements: • turn fireplace off (see To Turn Off Gas to Appliance) • see Troubleshooting, Page 16 BURNER AND PILOT FLAME PATTERNS Figure 21 shows correct burner flame pattern. Flame Adjustment Knob NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by appliance, causing brief patches of orange flame. Figure 18 - Setting Control Knobs TO TURN OFF GAS TO APPLIANCE 1. Push switch into OFF position. The pilot will remain lit for normal service. 2. Access control knobs. 3. Press gas control knob slightly and turn clockwise to OFF. Do not force. 4. Close equipment shutoff valve (see Figure 14, Page 10). If burner flame pattern is incorrect, as shown in Figure 22. • turn appliance off (see To Turn Off Gas to Appliance) • see Troubleshooting, Page 16 Thermopile 3/8" to 1/2" Pilot Burner 1/8" HAND-HELD REMOTE OPERATION Thermocouple NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instructions, Page 12. Piezo Igniter Figure 20 - Pilot Assembly Flame Pattern After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position on Remote Receiver (see Figure 19). NOTE: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery. Yellow Flames with Orange Streaks Figure 21 - Correct Burner Flame Pattern Control Knob Flame Adjustment Knob Selector Switch in REMOTE Position Figure 19 - Settings for Remote Operation 127042-01E Dark Orange Flames REMOTE OFF ON Piezo Igniter Figure 22 - Incorrect Burner Flame Pattern SuperiorFireplaces.US.com 13 INSPECTING BURNERS Continued CLEANING AND MAINTENANCE OPTIONAL HAND-HELD REMOTE CONTROL ACCESSORIES - MRC NOTICE: Use only alkaline batteries (included with MRC). Installing Receiver 1. Disconnect jumper wires from the control valve (see Figure 23). 2. Locate the battery cover on the back of the receiver (see Figure 24). 3. Install 4-AA batteries (included) into receiver before installing into fireplace. 4. Connect wires from remote receiver to control valve. See instructions provided with remote control kit for further information. Figure 23 - Disconnecting Jumper Wires From Control Valve WARNING: Turn off the appliance and allow to cool before cleaning. CAUTION: You must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc. Only limited cleaning will be required under normal use of this appliance. Dust the front grate and top of receiver/valve. Do not use cleaning fluids to clean logs or any other part of the appliance. If, after a period of use, the flames start to exhibit unusual shapes and behavior or the burner fails to ignite smoothly, then the burner holes may require some cleaning. If this happens, we recommend that you contact your nearest authorized service technician to get the appliance serviced. • Keep area around log set clean and clear of debris. • Periodically inspect the air mixer and burner tube for foreign matter blocking the air inlet and flame holes. HIGH ALTITUDE INSTALLATION When the fireplace is installed at an elevation above 2000 feet, you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for every 1000 feet above 2000 feet which they are installed. Check with your local gas company for proper orifice size identification. Requires 4-AA 1.5V alkaline batteries SAFETY DEVICE Frequency adjusting access hole ON REMOTE OF F ADJ. Slide Switch ON REMOTE OFF LEARN Learning button ve y co ff r e t Bat s on/o e slid Remote Receiver High Temperature Limit Switch The high temperature limit switch is located inside the upper right hand corner of the firebox. This feature will prevent the fireplace from operating at abnormally high temperatures. The burner will automatically turn off without interrupting the pilot flame; the limit switch will lock out and must be reset manually. To reset the limit switch: 1. Turn off the burner by turning the gas control knob clockwise to the off position. 2. Remove limit switch plate by removing two screws. 3. Carefully pull limit plate out and press the reset button. 4. Mount limit switch plate back using two screws previously removed. 5. Re-light the burner following instructions on Page 12. Figure 24 - Attaching Batteries to Receiver WARNING: Only a qualified service person should service the fireplace. 14 SuperiorFireplaces.US.com 127042-01E SPECIFICATIONS VRE3036ZMN VRE3042ZMN • • • • • Rating (Variable): 28,000/41,000 Btu/Hr Gas Type: Natural Ignition: Piezo Manifold Pressure: 3.5" W.C. Inlet Gas Pressure (inches of water): Max. 10.5" W.C., Min. 5.0" W.C.* • Air Shutter: 3/16 OPEN • • • • • VRE3036ZMP VRE3042ZMP • • • • • • • • • • Rating (Variable): 32,000/47,000 Btu/Hr Gas Type: Natural Ignition: Piezo Manifold Pressure: 3.5" W.C. Inlet Gas Pressure (inches of water): Max. 10.5" W.C., Min. 5.0" W.C.* • Air Shutter: 3/16 OPEN Rating (Variable): 35,000/45,000 Btu/Hr Gas Type: Propane/LP Ignition: Piezo Manifold Pressure: 10" W.C. Inlet Gas Pressure (inches of water): Max. 14" W.C., Min. 11" W.C.* • Air Shutter: FULLY OPEN *For purpose of input adjustment Rating (Variable): 32,000/41,000 Btu/Hr Gas Type: Propane/LP Ignition: Piezo Manifold Pressure: 10" W.C. Inlet Gas Pressure (inches of water): Max. 14" W.C., Min. 11" W.C.* • Air Shutter: FULLY OPEN WIRING DIAGRAM WARNING: Fireplace must be operated only with doors fully open. TO PILOT HEAT LIMIT SWITCH BLACK ELECTRICAL WIRE CONNECTION WILL REQUIRE MALE TO MALE CONNECTORS BLACK TPTH OPTIONAL ON/OFF SWITCH OPTIONAL REMOTER RECEIVER WHITE TP TH 127042-01E SuperiorFireplaces.US.com CONTROL VALVE INCOMING MAIN GAS SUPPLY 15 TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. NOTE: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When igniter button is pressed, there is no spark at pilot 1. Igniter electrode not connected to igniter cable 2. Igniter cable pinched or wet 1. Reconnect igniter cable 3. Piezo igniter nut is loose 4. Broken igniter cable 5. Bad piezo igniter 6. Igniter electrode broken 7. Igniter electrode positioned wrong When igniter button is pressed, there is spark at pilot but no ignition 1. Gas supply turned off or equipment shutoff valve closed 2. Gas control knob not in PILOT position 3. Gas control knob not pressed in while in PILOT position 4. Air in gas lines when installed 5. Depleted gas supply (propane/LP models only) 6. Pilot is clogged 7. Gas regulator setting is not correct Burner does not light after pilot is lit 1. Burner orifice clogged 2. Inlet gas pressure is too low 3. Thermopile leads disconnected or improperly connected 4. Thermopile is defective 16 SuperiorFireplaces.US.com 2. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry 3. Tighten nut holding piezo igniter. Nut is located behind the mounting bracket 4. Replace igniter cable 5. Replace piezo igniter 6. Replace pilot assembly 7. Tighten electrode. Replace if necessary 1. Turn on gas supply or open equipment shutoff valve 2. Turn gas control knob to PILOT position 3. Press in gas control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean pilot (see Cleaning and Maintenance, Page 14) or replace pilot assembly 7. Replace gas regulator 1. Clean burner (see Cleaning and Maintenance, Page 14) or replace burner orifice 2. Contact local propane/LP or natural gas company 3. Reconnect leads to TP & TPTH terminals on control valve 4. Replace thermopile 127042-01E TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot lights but flame goes out when control knob is released 1. Gas control knob not fully pressed in 2. Gas control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure 1. Press in gas control knob fully 2. After pilot lights, keep gas control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. B) Dirty or partially clogged pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged Delayed ignition burner 1. Manifold pressure is too low 2. Burner porting or orifice clogged 1. Burner orifice is clogged or damaged A) Contact local natural or propane/LP gas company B) Clean pilot (see Cleaning and Maintenance, Page 14) or replace pilot assembly 5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace pilot assembly 7. Replace control valve 1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance, Page 14) or replace burner orifice 2. Damaged burner 3. Gas regulator defective 1. Clean burner (see Cleaning and Maintenance, Page 14) or replace burner orifice 2. Replace damaged burner 3. Replace gas control Slight smoke or odor during initial operation 1. Residues from manufacturing processes and logs curing 1. Problem will stop after a few hours of operation Heater produces a whistling noise when burner is lit 1. Turning gas control knob to HI position when burner is cold 2. Air in gas line 1. Turn gas control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP or natural gas company 3. Clean burner (see Cleaning and Maintenance, Page 14) or replace burner orifice Burner backfiring during combustion 3. Dirty or partially clogged burner orifice Fireplace produces a clicking/ticking noise just after burners are lit or shut off 1. Metal expanding while heating or contracting while cooling 1. This is normal. If noise is excessive, contact qualified service person Remote does not function 1. Battery is not installed or battery power is low 1. Replace batteries in receiver and handheld remote control (see Page 14) 127042-01E SuperiorFireplaces.US.com 17 TROUBLESHOOTING Continued • • • • • • WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace produces unwanted odors 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, Page 11) Fireplace shuts off in use 1. High or gusting winds 1. Fireplace has been tested for up to 40 mph winds. However, extreme conditions may occur. See Lighting Instructions on Page 12 2. Contact local propane/LP or natural gas company 3. Clean pilot (see Cleaning and Maintenance, Page 14) 4. Locate and correct all leaks (see Checking Gas Connections, Page 11) 5. Tighten glass 2. Low line pressure 3. Pilot is partially clogged 4. Inner vent pipe leaking exhaust gasses into system 5. Glass too loose and air tight gasket leaks in corners after usage 6. Bad thermopile or thermocouple 7. Improper vent cap installation 8. Abnormal temperature in firebox due to doors not being fully open Gas odor even when control knob is in OFF position 1. Gas leak. See Warning statement above 2. Control valve defective 6. Replace faulty component 7. Check for proper installation and freedom from debris or blockage 8. See Safety Device, Page 14 1. Locate and correct all leaks (see Checking Gas Connections, Page 11) 2. Replace control valve Gas odor during combustion 1. Gas leak. See Warning statement above 1. Locate and correct all leaks (see Checking Gas Connections, Page 11) Dark residue on logs or inside of fireplace 1. Air holes at burner inlet blocked 1. Clean out air holes at burner inlets. Periodically repeat as needed 2. Remove blockage or replace burner 3. Have the vent system inspected, including the termination cap. Remove any restrictions or obstruction 4. Clear excess embers until a minimum gap of 1/2" remains under the grate 2. Burner flame holes blocked 3. Improper venting or excessive blockage 4. Excessive amounts of embers and pan material 18 SuperiorFireplaces.US.com 127042-01E SERVICE HINTS REPLACEMENT PARTS When Gas Pressure Is Too Low • pilot will not stay lit • burner will have delayed ignition • fireplace will not produce specified heat • for propane/LP unit, propane/LP gas supply may be low You may feel your gas pressure is too low. If so, contact your local gas supplier. See Pages 20 to 23 for a complete replacement parts list. Use only parts supplied from the manufacturer. Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns. When contacting your dealer please have your model and serial numbers of your fireplace ready. You can also visit our web site at SuperiorFireplaces.US.com. When ordering repair parts, always give the following information: 1. The model number of the fireplace. 2. The serial number of the fireplace. 3. The part number. 4. The description of the part. 5. The quantity required. 6. The installation date of the fireplace. If you encounter any problems or have any questions concerning the installation or application of this fireplace, please contact your dealer. IHP 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 Visit us at SuperiorFireplaces.US.com 127042-01E SuperiorFireplaces.US.com 19 PARTS 34 22 25 34 19 22 CAT. NO. F0519 MODEL VRE3036ZMN INTERIOR White Stacked F0520 VRE3036ZMP White Stacked F0521 VRE3036ZMN White Herr. F0522 VRE3036ZMP White Herr. F0527 VRE3042ZMN White Stacked F0528 VRE3042ZMP White Stacked F0529 VRE3042ZMN White Herr. F0530 VRE3042ZMP White Herr. 26 27 27 29 15 24 21 20 13 12 31 11 10 17 9 8 16 23 18 14 30 5 32 33 7 33 6 29 3 1 4 20 2 SuperiorFireplaces.US.com 127042-01E PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on Page 19 of this manual. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 CATALOG NO. See Pages 22 & 23 See Pages 22 & 23 See Pages 22 & 23 See Pages 22 & 23 See Pages 22 & 23 See Pages 22 & 23 See Pages 22 & 23 J5008 J5007 J4794 J5197 J4973 J4974 J4972 J4971 J4733 J6752 J6753 J6830 J6831 J5435 J5436 J5432 J8000 J3546 J4046 J6833 ** ** J4717 J5450 J5451 J6918 J6895 J6436 ** ** J5329 J6934 J6900 J8012 J8013 J6238 J6431 J6430 RP125354-02 RP125355-01 RP125355-02 RP125353-01 J4102 J8041 J4863 J6533 127042-01E DESCRIPTION VRE3036ZMN VRE3036ZMP Refractory, Bottom Rear • • Refractory, Bottom Right • • Refractory, Bottom Left • • Refractory, Bottom Center • • Refractory, Left • • Refractory, Right • • Refractory, Rear • • • • 1 1/4" Elbow Venturi 1 1/4" Elbow Venturi Venturi Gasket • • Air Shutter • • Brass Orifice NG • Brass Orifice LP • Brass Orifice NG Brass Orifice LP 3/8" Compression Nut/Sleeve • • Assembly, Pilot NT. (Alpine) • Assembly, Pilot LP. (Alpine) • Gas Valve (Natural) • Gas Valve (Propane/LP) • Log Set and NG Chassis • Log Set and LP Chassis • Log Set and NG Chassis Log Set and LP Chassis Piezo Igniter • • Valve Bracket • • 3/8 x 3/8 Brass Adapter • • Fireplace Top • • Fireplace Top Dormont T6-36 3.8 x 18" Flextube • • Log Set Retainer • • Log Set Retainer Top Spacer • • Firebrick Retainer • • High Limit Switch Assembly • • Fireplace Surround • • Fireplace Surround Handle Bracket • • Gas Conduit Cover • • Cover Outside Air Plate • • Screen Assembly Kit • • Screen Assembly Kit Fitting, 1/2" FLR x 3/8" MPT • • Pilot Sheild • • Frame, Top • • Frame, Top Frame, Sides • • Frame, Sides Top Spacer • • PARTS AVAILABLE — NOT SHOWN Wire Harness • • Flex Gas Line • • Ember Flakes Kit • • On/Off Remote • SuperiorFireplaces.US.com VRE3042ZMN • • • • • • • VRE3042ZMP • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • QTY. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 4 4 1 1 1 1 1 1 1 2 2 2 1 1 2 1 21 PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. WARNING LIFTING HAZARD SINGLE -PERSON LIFT COULD CAUSE INJURY. USE ASSISTANCE WHEN MOVING OR LIFTING. IMPORTANT: Installation of brick panels should be done after the fireplace is placed in a permanent location. 65 78 7 43 12 54 32 1 22 SuperiorFireplaces.US.com 127042-01E PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on Page 19 of this manual . KEY NO. 1 CATALOG NO. DESCRIPTION F3252 WHITE STACK REFRACTORY SET, 36" • F3254 WHITE STACK REFRACTORY SET, 42" F3253 WHITE HERRINGBONE REFRACTORY SET, 36" F3255 WHITE HERRINGBONE REFRACTORY SET, 42" 2 3 VRE3036 VRE3036 VRE3042 VRE3042 WHITE STACKED WHITE H.BONE WHITE STACKED WHITE H.BONE F0519 F0521 F0527 F0529 F0520 F0522 F0528 F0530 QTY. --- REFRACTORY, BTM REAR 36" WHITE --- REFRACTORY, BTM REAR 42" WHITE • • REFRACTORY, BTM FRONT RT.36"WHITE REFRACTORY, BTM FRONT RT.42"WHITE J5990 REFRACTORY, BTM FRONT LT.36"WHITE J5984 REFRACTORY, BTM FRONT LT.42"WHITE 5 J5427 REFRACTORY, BTM-CTR ASM, WHITE 36/42 • 6 --- REFRACTORY, LT,STD,WHITE C36 • --- REFRACTORY, LT, WHITE HERR C36 --- REFRACTORY, LEFT, WHITE 42 --- REFRACTORY, LEFT, WHITE HERR 42 --- REFRACTORY, RT,STD,WHITE C36 --- REFRACTORY, RT, WHITE HERR C36 --- REFRACTORY, RIGHT, WHITE 42 --- REFRACTORY, RIGHT, WHITE HERR 42 --- REFRACTORY, REAR,STD,WHITE C36 --- REFRACTORY, REAR, WHITE HERR C36 --- REFRACTORY, REAR, WHITE 42 --- REFRACTORY, REAR WHITE HERR 42 8 127042-01E 1 • J5988 7 1 • J5982 4 1 • • • 1 • • • • • 1 1 • • 1 • • 1 1 • 1 • 1 • • 1 1 • 1 • 1 • • 1 1 • 1 • SuperiorFireplaces.US.com 1 1 • • 1 1 • 1 23 ACCESSORIES Purchase these appliance accessories from your local dealer. If they can not supply these accessories, contact IHP at SuperiorFireplaces. US.com for referral information. You can also write to the address listed on the back of this manual. Only kits supplied by IHP shall be used in the installation of this appliance. Use of non-approved accessory/part kit(s) can result in poor performance and safety hazards. CAT NO. MODEL DESCRIPTION RECEIVER AND HAND-HELD REMOTE CONTROL ON F2236 RCKIT4001 On/Off Remote and Receiver with White Wall Plate (1) F1079 TSRC Receiver and Touch Screen Remote Control Kit (2) F1080 WRC Standard Electronic On/Off Remote Control Kit (3) OFF PROG (1) MODE SET (2) (3) FIREPLACE HOOD F1052 HS36 36" Stainless Steel Hood w/4" Brow F1053 HS42 42" Stainless Steel Hood w/4" Brow (Not shown) DRAIN PAN F1089 DP36 F1090 DP42 36" Drain Pan w/ 1" Stainless Decorative Face Extension 42" Drain Pan w/ 1" Stainless Decorative Face Extension (Not shown) BI-FOLD GLASS DOORS F0987 BDO36 36" Outdoor Bi-Fold Glass Door - Black finish F0988 BDO36B 36" Outdoor Bi-Fold Glass Door - Brushed Brass finish F0989 BDO36P 36" Outdoor Bi-Fold Glass Door - Platinum finish F0990 BDO42 42" Outdoor Bi-Fold Glass Door - Black finish F0991 BDO42B 42" Outdoor Bi-Fold Glass Door - Brushed Brass finish F0992 BDO42P 42" Outdoor Bi-Fold Glass Door - Platinum finish METAL OUTDOOR COVER Door for closing unit when not in use F1034 OC36 36" Outdoor Fireplace Panel Cover F1035 OC42 42" Outdoor Fireplace Panel Cover GAS CONVERSION KITS 24 F1134 PCVM-36O 36", Millivolt - NG to LP F1135 NCVM-36O 36", Millivolt - LP to NG F1136 PCVM-42O 42", Millivolt - NG to LP F1137 NCVM-42O 42", Millivolt - LP to NG SuperiorFireplaces.US.com (Not shown) 127042-01E ACCESSORIES Continued REFRACTORY STAIN KITS Use the Refractory Stain Kits to give white refractory panels a new look. Kit includes foam roller, roller handle, paint tray, and one can of stain. Available stain colors are Creamer (ivory), Rust (terra cotta), and Cappuccino (rosy taupe). H8176 BSK-CR Refractory Stain Kit, Creamer H8177 BSK-RT Refractory Stain Kit, Rust H8178 BSK-CP Refractory Stain Kit, Cappuccino 127042-01E SuperiorFireplaces.US.com Creamer Rust Cappuccino 25 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ 26 SuperiorFireplaces.US.com 127042-01E Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts 20 Year Limited Warranty ® THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior® Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, firebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 Year Limited Warranty as described herein. COVERAGE COMMENCEMENT DATE Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date. EXCLUSIONS AND LIMITATIONS This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices. This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The product body, firebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows: Burner – Repair or replacement for one year from the date of installation Gas components – Repair or replacement for one year from the date of installation Gaskets – Repair or replacement for one year from the date of installation Logs – Replacement for one year from the date of installation against thermal breakage only Optional blowers & remote controls – Repair or replacement for one year from the date of installation Optional glass doors – Repair or replacement for 90 days from the date of installation Tempered glass - Replacement for one year from the date of installation Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component Parts not otherwise listed carry a 90 day warranty from the date of installation. Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product. IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product. IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit. This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory. LIMITATION ON LIABILITY It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein. In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness for a particular use or purpose. IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty. No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law. INVESTIGATION OF CLAIMS AGAINST WARRANTY IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement. To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a contractor that is not approved without first obtaining IHP's prior written consent. HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM. Printed in U.S.A. © 2013 Innovative Hearth Products P/N 900223-00, Rev. B 10/2016 Innovative Hearth Products 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210 27 SuperiorFireplaces.US.com Record the following important information about your appliance: Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2014 Innovative Hearth Products 28 P/N 127042-01 Rev. E 01/2017 P127042-01 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement