LG E l e c t ro n i c s C a n a d a I n c .
1- 888 - LG - C a n a d a ( 542 - 2623 ) w w w. LG . c a
PG-100-2006-VER1
ELEGANT. EFFICIENT. EXTRAORDINARY.
PRODUCT GUIDE
Ductless Air Conditioning Systems
ARTCOOL™ • Mini-Split • Flex Multi Split
Floor Standing • Ceiling Cassette
PTAC
MINI-SPLIT ART COOL, SINGLE ZONE
9,000 and 12,000 BTUs
Cooling, and Heat Pump
12,000 BTUs
Cooling, and Heat Pump
18,000 BTUs
Cooling
MINI-SPLIT STANDARD, SINGLE ZONE
9,000-24,000 BTUs
Cooling and Heat Pump
30,000 BTUs
Cooling and Heat Pump
FLEX MULTI SPLIT, DUAL & TRI-ZONE
Dual Zone: Mix and match for 18,000 to 24,000 BTUs
Tri-Zone: Mix and match for 27,000 to 36,000 BTUs
Cooling and Heat Pump
1
FLOOR STANDING & CEILING CASSETTE, SINGLE ZONE
28,000 BTUs
Cooling
48,000 BTUs
Cooling
24,000 and 34,000 BTUs
Cooling
PACKAGED TERMINAL AIR CONDITIONERS
7,000-15,000 BTUs
Heat/Cool
ENVIRONMENTALLY FRIENDLY
LG air conditioners are environmentally friendly
and future-oriented.
To reduce Freon gas, a prime ozone destroyer,
they adopt alternative refrigerant R-410A, and
neo plasma air-purifying system for powerful
sterilization for health-conscious customers.
Also, ARTCOOL™ series with outstanding
designs have received International Forum
Design Award and Reddot Design Award.
They have improved air flow innovatively to
realize world’s lowest noise, and provide a more
pleasant and convenient indoor environment.
2
The LG HVAC Advantage
Take advantage of our smart solutions for residential &
commercial air conditioning applications.
LG HVAC systems offer a range of solutions that are cost-efficient,
quiet, and attractive. They provide a smart alternative to both central
HVAC and window-mounted air conditioners, and are available in a
variety of configurations to suit different cooling and heating situations.
Split Systems
These innovative systems are “split” into indoor and outdoor units.
The interior units are available in several different configurations:
ARTCOOL™, standard wall-mounted, floor standing and ceiling
cassettes. All interior units have remote controls for easy use.
Installation by a qualified HVAC contractor is safe and easy—no
duct work or sheet metal is needed. Single, dual and tri-zone
systems, as well as cooling only and heat pump models are
available.
PTAC Models
• Triple-Filter Air Purifying System. An electrostatic filter removes
dust, pollen and smoke; an anti-fungal filter prevents bacteria and
mold from forming; and a deodorizing filter freshens the air.
• ARTCOOL™ Self-Cleaning Indoor Coil. Drives dirt and
moisture from coil surface leaving it clean and fresh smelling.
• Dehumidifying Mode. Indoor unit accurately senses room
temperature and controls humidity by shutting down the
compressor before a room is over-cooled.
• Chaos Swing. Electronically controlled louvers and fan speeds
create a more natural, random flow of air, reducing temperature
stratification.
• ARTCOOL™ Three-way Cooling. Air flows out of the unit
from three directions, creating more natural circulation.
• Jet Cool. Operates at high speed for up to 30 minutes to
quickly cool a room down to 65° F.
• Swirl Wind. Four-way controlled louvers and fan speeds create
LG’s new PTAC units are perfect for lodging and healthcare
a stronger, wider air flow and reduces temperature stratification.
applications. These units have an extremely low decibel level and
outstanding sound ratings. Plus, LG models have efficiency ratings up • Auto Operation. Provides three levels of comfort from which to
to 12.7 EER, which translates into excellent energy savings.
choose. Temperature and fan speed will set automatically.
Feature Advantages:
Look for these key features throughout the LG line.
• Attractive, customizable indoor units. ARTCOOL™
provides numerous options to compliment any décor. The
ARTCOOL™ Customizable Art Panel works like a picture frame
– any art or photograph can be displayed. Other ARTCOOL™
units come in a variety of beautiful colors and finishes to suit
any room.
• Multi Power System.™ Energy-saving twin
compressors: one provides power at 60%
capacity until the system reaches a desired
temperature. Then the smaller compressor takes over to provide
sustained operation at 40% capacity, saving money and energy.
• Manual Power Switch. Easily accessed button that allows for
continued operation if the remote control is misplaced.
• Defrost Control. Shuts down the indoor fan to prevent cold air
from being blown into the house. Removes frost from outdoor
coil when the outdoor temperature is low (Heat Pump only).
• Temperature Display. Shows room temperature of interior
unit.
• Auto Sleep Mode. Automatically increases the temperature
setting 2° F twice (after 1/2 hour and one hour). The interior
unit shuts off when the timer setting is reached.
• Auto Restart. Automatically restarts a unit to programmed
setting when the electricity comes on after a power failure.
• R-410A Refrigerant. Environmentally friendly
refrigerant utilized in the majority of LG systems.
• Neo Plasma Air Purifying System. The 4-stage system
features a large, permanent filter and an electronic air purifier
that captures microscopic contaminants like dust, mite, pollen,
and pet fur.
NOTE: All features are not available on all models.
See product pages for details.
The LG HVAC Advantage
Ultra Silent Operation
Cross-flow fan operates at low speed but generates more air.
The special fan housing creates a smooth and quiet air flow.
1
2
78dB
Typing
The Quiet operation has a three-layer and new design
1
Less noise with a three-layer, anti-noise mechanism
A three-layer, anti-noise mechanism covers the noise
coming from the fan and the motor.
2
55dB
Office
50dB
40dB
20dB
28dB
Conversation Library Indoor Unit Empty Studio
Conveniently attaches to the wall
The double-tubing cover minimizes space between the wall
and the air conditioner in order to reduce the noise caused
by motor vibration.
Chaos Swing
A natural air flow system. Computer-controlled vanes create a more natural flow of air, reducing temperature stratification.
Indoor Temperature Distribution Chart
Up speed :12ms(Slow)
Down speed :6ms(fast)
Wind-up Effects:
The Wind-up Effect is
controlled by the Vane
Angle Control to evenly
distribute nature-like air
throughout the room.
Chaos Swing
Auto Swing
It swings at an angle twice wider than
that in conventional air conditioners,
thus minimizing differences in indoor
temperatures, and allowing air to
circulate in every corner of the room.
4-Way Auto Swing
Even & Fast Cooling
Air flows in 4 directions,
creating more natural circulation.
Have an even and fast air flow with the
Twin Air Vane™, which regulates cool and warm air.
Cooling mode
0.5hr
LG
Co., A
Co., B
1hr
2hr
The LG HVAC Advantage
Perfect Finishing
Additional wide cover to hold tubing assembly
1
2
Wide area for piping & drain hose
arrangement, wide cover to hold
piping & drain hose.
3
Installation fully and strongly Inserted
structure
Additional wide cover to hold tubing
assembly
LG LG
New
Conventional
- Gap from the wall : 1~2mm
- Gap from the wall : 5~8mm
Optimum Effective Cooling
LG Wall Mounted Split models feature a Dehumidification mode to remove uncomfortable humidity from the room
without over cooling.
Conventional
LG
Since the surrounding temperature is measured after
the air from the unit is widely distributed, an accurate
assessment of the air is not possible.
By increasing the vane angle, a better assessment of
the actual temperature is possible to prevent over
cooling.
Jet Cool Operation
Jet Cool operates at a high speed for up to 30 minutes to quickly cool a room down to 18°C.
It can cool a certain area up to 10 meters away.
35ºC
10m
26ºC
ART COOL™
Available styles and finishes
ART COOL
MINI-SPLIT
SINGLE ZONE
Customized good looks
The slim, contemporary styling of the Art Cool™ models
will appeal to today’s discerning customer. The 9,000 and
12,000 BTU picture models come with a frame that allows
the customer to modify and personalize the unit with their
own artwork or photography – the ultimate in custom
Mini-Split
ARTCOOL™ Indoor Unit
Customizable Art Panel
design. Other indoor units are available in popular
finishes and colors to compliment any décor.
Ductless Mini-Split Air conditioning Systems from LG
maximize the efficiency and economics of ductless
technology. Now you can bring more attractive, cost
effective solutions to your commercial and residential
customers, providing single zone systems in both air
conditioning and heat pump models.
Mini-Split
ARTCOOL™ Indoor Unit
Mirror Finish
Indoor Unit with Remote
LOW
36V
DC
INDOOR UNIT
OPERATION
Mini-Split
ARTCOOL™ Indoor Unit
Metal Finish
Outdoor Unit
Neo Plasma
Outstanding
air purification
The wall unit features LG’s Neo Plasma Air Purifying System
that provides excellent indoor air quality. Freshen the air
anytime, whether cooling a room or operating in fan only mode.
5
HIGH WALL DUCTLESS • ART COOL MINI-SPLIT SINGLE ZONE
9,000 BTUs
12,000 BTUs
LA090CP (A/C Model)
LA120CP(A/C Model)
9,000 BTUs Cooling
12,000 BTUs Cooling
LA090HP (H/P Model)
LA120HP (H/P Model)
9,000 BTUs Cooling
9,000 BTUs Heating
12,000 BTUs Cooling
12,000 BTUs Heating
Features:
• Customizable art panel
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Self-cleaning indoor coil
• Dehumidifying mode
• Chaos Swing
• Three-way cooling
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
System Model #
LA090CP
LA090HP
LA120CP
LA120HP
Indoor Model #
Outdoor Model #
LA090CPI
LA090CPO
LA090HPI
LA090CPO
LAN120CPI
LAU120CPO
LAN120HPI
LAU120HPO
Capacity (BTUs)
9,000
12,000
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hour)
Indoor dB(A)*
Outdoor dB(A)*
13
283/230/177
4/Auto/Chaos
2.6
35/30/25
48
9,000
9,000
13
283/230/177
4/Auto/Chaos
2.6
35/30/25
48
13
330/261/194
4/Auto/Chaos
3.0
41/35/29
48
12,000
12,000
13
330/261/194
4/Auto/Chaos
3.0
41/35/29
48
115-60-1
36V DC
23 5/8 x
23 5/8 x
5 3/4
30.9
30 5/16 x
21 5/16 x
9 5/8
66.1
115-60-1
36V DC
23 5/8 x
23 5/8 x
5 3/4
30.9
30 5/16 x
21 5/16 x
9 5/8
66.1
115-60-1
36V DC
23 5/8 x
23 5/8 x
5 3/4
30.9
30 5/16 x
21 5/16 x
9 5/8
70.5
115-60-1
36V DC
23 5/8 x
23 5/8 x
5 3/4
30.9
30 5/16 x
21 5/16 x
9 5/8
70.5
64-86
64-86/60-86
64-86
64-86/60-86
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
6
Warranty: 2 years parts and labour; 5 years compressor.
See page 10 for electrical specifications, refrigerant line requirements & formulas.
HIGH WALL DUCTLESS • ART COOL MINI-SPLIT SINGLE ZONE
How to replace the picture in your customizable ARTCOOL™
air conditioning unit:
1
2
3
1. Turn off the power.
2. Pull open the top part of the front panel.
3. Pull out tabs from the bottom of the front panel, then pull the bottom of the panel
forward, until it is secured. Take out the existing picture from under the panel.
4. Slide the new picture under the panel, and press the front panel shut.
5. Secure the tabs on the bottom of the front panel
6. Your new picture should now be displayed
in your LG ARTCOOL™.
4. Slide the new picture under the panel, and press the front
panel shut.
5. Secure the tabs on the bottom of the front panel
6. Your new picture should now be displayed in your LG
ARTCOOL™.
4
5
6
Warranty: 2 years parts and labour; 5 years compressor.
See page 10 for electrical specifications, refrigerant line requirements & formulas.
7
8
HIGH WALL DUCTLESS • ART COOL MINI-SPLIT SINGLE ZONE
12,000 BTUs
LA121CPM (A/C Model)
11,500 BTUs Cooling
LA121HPM (H/P Model)
11,500 BTUs Cooling
11,500 BTUs Heating
Features:
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Self cleaning indoor coil
• Dehumidifying mode
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Evaporator frost control
• Ultra-quiet operation
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
System Model #
LA121CPM
LA121CPM
Indoor Model #
Outdoor Model #
LAN121CPMI
LAU121CPMO
LAN121CPMI
LAU121CPMO
Capacity (BTUs)
11,500
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hour)
Indoor dB(A)*
Outdoor dB(A)*
13
330/261/194
4/Auto/Chaos
3.0
41/38/34
48
11,500
11,500
13
330/261/194
4/Auto/Chaos
3.0
41/38/34
48
115-60-1
36V DC
36 x
11 3/32 x
6 1/2
20.5
30 5/16 x
21 5/16 x
9 5/8
70.5
115-60-1
36V DC
36 x
11 3/32 x
6 1/2
20.5
30 5/16 x
21 5/16 x
9 5/8
70.5
64-86
64-86/60-86
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
8
Warranty: 2 years parts and labour; 5 years compressor.
See page 10 for electrical specifications, refrigerant line requirements & formulas.
• Remote control, batteries,
holder & holder hardware
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
HIGH WALL DUCTLESS • ART COOL MINI-SPLIT SINGLE ZONE
18,000 BTUs
LA180CP (A/C Model)
18,000 BTUs Cooling
Features:
• Multi Power System™
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Self cleaning indoor coil
• Dehumidifying mode
• Chaos Swing
• Three-way cooling
• Jet Cool
• Cooling mode
• Fan mode
• Auto operation
• Manual power switch
• Temp. display on indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
System Model #
LA180CP
Indoor Model #
Outdoor Model #
LAN180CPI
LAU180CPO
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
Performance
Capacity (BTUs)
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hour)
Indoor dB(A)*
Outdoor dB(A)*
18,000/17,800
13
460/353/247
4/Auto/Chaos
5.3
44/40/36
55
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
230/208-60-1
36V DC
36 1/2 x
20 19/32 x
5 25/32
37.5
34 5/16 x
25 13/16 x
12 5/8
149.9
Thermostat Range
Cooling / Heating (°F)
64-86
*LG verified sound ratings
Warranty: 2 years parts and labour; 5 years compressor.
See page 10 for electrical specifications, refrigerant line requirements & formulas.
9
ART COOL MINI-SPLIT SINGLE ZONE
ELECTRICAL & REFRIGERATION • QUICK REFERENCE
Electrical Specifications
Type
Model
BTUs
Voltage
Indoor
Outdoor
A/C
A/C
A/C
A/C
H/P
H/P
H/P
LA090CP
LA120CP
LA121CPM
LA180CP
LA090HP
LA120HP
LA121HPM
9,000
12,000
11,500
18,000
9,000
12,000
11,500
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
ARTCOOL ™
Single Zone
115
115
115
230/208
115
115
115
Rated Amps
MCA*
MOP**
7.2
9.3
10.5
9.8
7.2
9.3
10.5
15
15
15
15
15
15
15
15
20
20
20
20
20
20
All equipment single phase.
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.
Wire Size
Minimum AWG
Indoor/Outdoor Connecting Cable Shielded
14-3
18-4
Refrigerant Line Specifications***
Type
Model
BTUs
A/C
A/C
A/C
A/C
H/P
H/P
H/P
LA090CP
LA120CP
LA121CPM
LA180CP
LA090HP
LA120HP
LA121HP
9,000
12,000
11,500
18,000
9,000
12,000
11,500
ARTCOOL ™
Single Zone
Pipe Size
Liquid
Suction
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
3/8"
1/2"
1/2"
1/2"
3/8"
1/2 "
1/2 "
Additional Max. Pipe
Refrigerant Length
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil
trapped between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least
every 12 ft. of elevation.
Max.
Elevation
50'
50'
50'
100'
50'
50'
50'
25'
25'
25'
50'
25'
25'
25'
OUTDOOR UNIT
OIL TRAP
INDOOR UNIT
25' maximum
8' minimum
12' maximum
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above
indoor unit.
Figure A.
Example: 25 ft. maximum elevation.
10
Mini-Split Standard systems utilize the same
ductless technology as ARTCOOL™ units, in a
MINI-SPLIT STANDARD
MINI-SPLIT
STANDARD AIR
CONDITIONERS
SINGLE ZONE
Available styles
Mini-Split Standard Indoor Unit White
Cooling and Heat Pump
9,000-24,000 BTUs
streamlined, low profile design. Models are
available in a variety of sizes from 9,000
through 30,000 BTUs. LG’s Mini-split
standard air conditioners are easy-to-install,
efficient and cost effective.
Mini-Split Standard Indoor Unit White
Cooling and Heat Pump
30,000 BTUs
Indoor Unit
LOW
36V
DC
INDOOR UNIT
OPERATION
Outdoor Unit
11
HIGH WALL DUCTLESS • MINI-SPLIT STANDARD SINGLE ZONE
9,000 BTUs
LS090CP (A/C Model)
9,000 BTUs Cooling
LS090HP (H/P Model)
9,800 BTUs Cooling
9,800 BTUs Heating
Standard Features:
• R-410A Refrigerant
• Dehumidifying mode
• Neo Plasma Air Purifying
System
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on
indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Built-in low ambient standard,
down to 0°F (cooling mode)
• Ultra-quiet operation
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
System Model #
LS090CP
LS090HP
Indoor Model #
Outdoor Model #
LSO90CPI
LSO90CPO
LSO90HPI
LSO90HPO
Capacity (BTUs)
9,000
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
13
250/210/170
4/Auto/Chaos
2.6
36/31/28
48
9,800
9,800
13
330/280/230
4/Auto/Chaos
3.0
41/36/34
48
115-60-1
36V DC
33 1/16 x
10 5/8 x
6 1/32
15.4
30 5/16 x
21 5/16 x
9 19/32
66.1
115-60-1
36V DC
35 3/16 x
11 x
6 1/32
15.4
30 5/16 x
21 5/16 x
9 19/32
72.8
64-86
64-86/60-86
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
12
Warranty: 2 years parts and labour; 5 years compressor.
See page 17 for electrical specifications, refrigerant line requirements & formulas.
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
HIGH WALL DUCTLESS • MINI-SPLIT STANDARD SINGLE ZONE
12,000 BTUs
LS120CP (A/C Model)
12,000 BTUs Cooling
LS120HP (H/P Model)
11,500 BTUs Cooling
11,500 BTUs Heating
Standard Features:
• R-410A Refrigerant
• Dehumidifying mode
• Neo Plasma Air Purifying
System
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on
indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Built-in low ambient standard,
down to 0°F (cooling mode)
• Ultra-quiet operation
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
System Model #
LS120CP
LS120HP
Indoor Model #
Outdoor Model #
LS120CPI
LS120CPO
LS120HPI
LS120HPO
Capacity (BTUs)
12,000
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
13
330/280/230
4/Auto/Chaos
3.0
41/36/34
48
11,500
11,500
13
330/280/230
4/Auto/Chaos
3.0
41/36/34
48
115-1-60
36V DC
35 3/16 x
11 x
6 1/2
20.5
30 5/16 x
21 5/16 x
9 19/32
70.5
115-1-60
36V DC
35 3/16 x
11 x
6 1/2
20.5
30 5/16 x
21 5/16 x
9 19/32
72.8
64-86
64-86/60-86
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
Warranty: 2 years parts and labour; 5 years compressor.
See page 17 for electrical specifications, refrigerant line requirements & formulas.
14
13
HIGH WALL DUCTLESS • MINI-SPLIT STANDARD SINGLE ZONE
18,000 BTUs
LS180CP (A/C Model)
18,000 BTUs Cooling
LS180HP (H/P Model)
19,500 BTUs Cooling
19,500 BTUs Heating
Standard Features:
• Multi Power System™
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Dehumidifying mode
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on
indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Ultra-quiet operation
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
• Installation manual
System Model #
LS180CP
LS180HP
Indoor Model #
Outdoor Model #
LS180CPI
LS180CPO
LS180HPI
LS180HPO
Capacity (BTUs)
18,000/17,800
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
13
460/380/320
4/Auto/Chaos
5.3
41/38/36
55
19,500/19,000
19,500/19,000
13
530/450/370
4/Auto/Chaos
6.6
46/41/38
57
230/208-60-1
36V DC
42 15/16 x
11 13/16 x
7 1/32
28.6
34 5/16 x
25 13/16 x
12 5/8
149.9
230/208-60-1
36V DC
42 15/16 x
11 13/16 x
7 1/32
28.6
34 5/16 x
25 13/16 x
12 5/8
169.6
64-86
64-86/60-86
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
14
Warranty: 2 years parts and labour; 5 years compressor.
See page 17 for electrical specifications, refrigerant line requirements & formulas.
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
HIGH WALL DUCTLESS • MINI-SPLIT STANDARD SINGLE ZONE
24,000 BTUs
LS240CP (A/C Model)
22,500 BTUs Cooling
LS240HP (H/P Model)
22,500 BTUs Cooling
22,500 BTUs Heating
Standard Features:
• Multi Power System™
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Dehumidifying mode
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on
indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Ultra-quiet operation
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
• Installation manual
System Model #
LS240CP
LS240HP
Indoor Model #
Outdoor Model #
LS240CPI
LS240CPO
LS240HPI
LS240HPO
Capacity (BTUs)
22,500/22,100
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
13
530/450/370
4/Auto/Chaos
6.6
46/41/38
57
22,500/22,100
22,500/22,100
13
530/450/370
4/Auto/Chaos
6.6
46/41/38
57
230/208-60-1
36V DC
42 15/16 x
11 13/16 x
7 1/32
28.6
34 5/16 x
31 1/2 x
12 5/8
166.6
230/208-60-1
36V DC
42 15/16 x
11 13/16 x
7 1/32
28.6
34 5/16 x
31 1/2 x
12 5/8
169.6
64-86
64-86/60-86
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
Warranty: 2 years parts and labour; 5 years compressor.
See page 17 for electrical specifications, refrigerant line requirements & formulas.
15
HIGH WALL DUCTLESS • MINI-SPLIT STANDARD SINGLE ZONE
30,000 BTUs
LS302CP (A/C Model)
28,000 BTUs Cooling
LS302HP (H/P Model)
28,000 BTUs Cooling
29,000 BTUs Heating
Standard Features:
• Multi Power System™
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Dehumidifying mode
• Chaos Swing
• Jet Cool
• Cooling mode
• Heating mode (H/P model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on
indoor unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Ultra-quiet operation
• Evaporator frost control
Interior Unit Includes:
• Wall unit
• Installation plate & hardware
• Remote control, batteries,
holder & holder hardware
• Installation manual
System Model #
LS302CP
LS302HP
Indoor Model #
Outdoor Model #
LS302CPI
LS302CPO
LS302HPI
LS302HPO
Capacity (BTUs)
28,000/27,000
SEER
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
13
740/630/520
4/Auto/Chaos
7.8
48/44/40
63
28,000/27,000
29,000/29,000
13
740/630/520
4/Auto/Chaos
7.8
48/44/40
63
230/208-60-1
36V DC
47 19/32 x
13 5/8 x
8 1/16
37.5
34 5/16 x
40 7/8 x
12 5/8
178.6
230/208-60-1
36V DC
47 19/32 x
13 5/8 x
8 1/16
37.5
34 5/16 x
40 7/8 x
12 5/8
180.3
64-86
64-86 /60-86
Performance
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
16
Warranty: 2 years parts and labour; 5 years compressor.
See page 17 for electrical specifications, refrigerant line requirements & formulas.
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
MINI-SPLIT STANDARD SINGLE ZONE
ELECTRICAL & REFRIGERATION• QUICK REFERENCE
Electrical Specifications
Type
System Model #
Voltage
BTUs
Rated
Indoor
Outdoor
Amps
MCA*
MOP**
Mini-Split
A/C
LS090CP
9,000
36V DC
115
7.0
15
15
Standard
A/C
LS120CP
11,500
36V DC
115
10.5
15
25
Single Zone A/C
LS180CP
18,000
36V DC
230/208
8.6/9.5
15
20
A/C
LS240CP
22,500
36V DC
230/208
11.5/12.5
20
30
A/C
LS302CP
28,000
36V DC
230/208
14.5/15.6
25
30
H/P
LS090HP
9,800
36V DC
115
10.5
15
25
H/P
LS120HP
11,500
36V DC
115
10.5
15
30
H/P
LS180HP
19,500
36V DC
230/208
11.5/12.5
20
30
H/P
LS240HP
22,500
36V DC
230/208
11.5/13.0
20
30
H/P
LS302HP
28,000
36V DC
230/208
14.5/15.6
25
30
All equipment single phase.
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
***For LS180HP, LS240CP/HP, LS302CP/HP
NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.
Wire Size
Minimum AWG
14-3
12-3***
18-4
Indoor/Outdoor Connecting Cable Shielded
Refrigerant Line & Formula Specifications***
System
Model #
BTUs
Pipe size
Liquid Suction
Additional
Refrigerant
Max. length
each pipe
Max.
elevation
Mini Split A/C
Standard
A/C
Single Zone A/C
LS090CP
9,000
1/4"
3/8"
0.25 oz./ft.
50'
25'
LS120CP
11,500
1/4"
1/2 "
0.25 oz./ft.
50'
25'
LS180CP
18,000
1/4"
1/2 "
0.25 oz./ft.
100'
50'
A/C
LS240CP
22,500
1/4"
5/8"
0.25 oz./ft.
100'
50'
A/C
LS302CP
28,000
1/4"
5/8"
0.35 oz./ft.
100'
50'
H/P
LS090HP
9,000
1/4"
1/2"
0.25 oz./ft.
50'
25'
H/P
LS120HP
11,500
1/4"
1/2 "
0.25 oz./ft.
50'
25'
H/P
LS180HP
19,500
1/4"
5/8 "
0.25 oz./ft.
100'
50'
H/P
LS240HP
22,500
1/4"
5/8"
0.25 oz./ft.
100'
50'
H/P
LS302HP
28,000
1/4"
5/8"
0.35 oz./ft.
100'
50'
Type
***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with elevation of 25 ft. (see figure A), refrigerant lines must be oil trapped
between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at
least every 12 ft. of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above
indoor unit.
OUTDOOR UNIT
OIL TRAP
INDOOR UNIT
25' maximum
8' minimum
12' maximum
Figure A.
Example: 25 ft. maximum elevation.
Must install trap inverted.
17
ATTRACT YOUR
ATTENTION
LG is the first company in the world to introduce
the design concept of ARTCOOL™. We have introduced
emotional elements to air conditioners beyond their
functional features, and thus ARTCOOL™’s refined
modern designs are created to highlight your own
individuality and style.
We believe that everything in your home should offer
you convenience and pleasure. ARTCOOL™ has thus
won world-class design awards because of its
remarkable concept.
If you’re looking for something innovative and attractive
that fits you, put it up on a wall with a painting by a
master. The classic ART COOL type lets you express
your personality and also make an artistic statement.
CHANGE STYLES
LG ARTCOOL™ allows you to change the image of the
panel to match your interior’s color scheme.
This air conditioner can simulate the ambiance
you want, allowing you full control
to enjoy your life.
The panel, with mirror-like finish, will inject a more
modern and stylish sense in your interiors.
18
Flex Multi Split Systems
The larger, Flex Multi Split systems operate two or three interior
units that are mounted in separate rooms. Each indoor unit
comes with it’s own remote control, allowing the customer to set
FLEX MULTI SPLIT• DUAL ZONE•TRI-ZONE
FLEX MULTI SPLIT
AIR CONDITIONERS
DUAL ZONE &
TRI-ZONE
Available styles and finishes
Flex Multi Split
ARTCOOL™ Indoor Unit
Mirror Finish
12,000 BTU’s
Cooling only
or Heat Pump
the temperature individually in different rooms. These units are
connected to a single exterior unit.
9,000 and 12,000 Flex Multi indoor units can be combined to
achieve between 18,000 and 24,000 BTUs on a Dual Zone
system, and from 27,000 to 36,000 BTUs on a Tri-Zone system.
The interior units are available in a variety of styles including
ARTCOOL™ and Standard models. Both Dual Zone and Tri-Zone
are available in Cooling Only or Heat Pump systems.
Flex Multi Split
ARTCOOL™ Indoor Unit Metal
Finish
9,000/12,000 BTU’s
Cooling only
or Heat Pump
Flex Multi Split
Standard Indoor Unit
9,000/12,000 BTU’s
Cooling only
or Heat Pump
19
HIGH WALL DUCTLESS • FLEX MULTI SPLIT
18,000-24,000 BTUs Dual Zone
Outdoor Unit
Outdoor Unit
LM0240C
LM0240H
Choose any two indoor cooling units for a
combined 18,000 - 24,000 BTUs cooling.
Pick the same style, or mix and match.
Choose any two indoor heat pump units for a
combined 18,000 - 24,000 BTUs heating/cooling.
Pick the same style, or mix and match.
Outdoor Unit Cooling LMO240C
Outdoor Unit Heat Pump LMO240H
27,000-36,000 BTUs Tri-Zone
Outdoor Unit
Outdoor Unit
LMO360C
LMO360H
Choose any three indoor cooling units for a
combined 27,000 - 36,000 BTUs cooling.
Pick the same style, or mix and match.
Choose any three indoor heat units for a combined
27,000 - 36,000 BTUs heating/cooling. Pick the
same style, or mix and match.
Outdoor Unit Cooling LMO360C
Outdoor Unit Heat Pump LMO360H
Model #
LMIO90CP
LMAO90CP
LMI120CP
LMA120CP
LMA121CPM
Performance
Capacity (BTUs)
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
9,000/8,850
250/210/170**
4/Auto/Chaos
2.3
31/29/22
50
9,000/8,850
264/230/177**
4/Auto/Chaos
2.3
37/31/27
50
12,000/11,800
330/280/230**
4/Auto/Chaos
2.5
39/25/21
50
12,000/11,800
265/230/177**
4/Auto/Chaos
3.0
43/39/31
50
12,000/11,800
330/261/194**
4/Auto/Chaos
2.5
39/25/21
50
230/208-60-1
36V DC
33 1/16 x
10 5/8 x
6 1/32
15.4**
230/208-60-1
36V DC
22 13/32 x
22 13/32 x
5 3/8 x
24.9**
230/208-60-1
36V DC
35 3/16 x
11 x
6 1/2
20.5**
230/208-60-1
36V DC
22 13/32 x
22 13/32 x
5 3/8 x
24.9**
230/208-60-1
36V DC
36 x
11 3/32 x
6 1/2
20.5**
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
64-86
64-86
64-86
64-86
64-86
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
Dual Zone
W x H x D (inches)
Tri Zone
W x H x D (inches)
Dual Zone Weight (lbs.)
Tri Zone Weight (lbs.)
Thermostat Range
TH-Zone Cooling /
Heating (°F)
*LG verified sound ratings
**Per indoor unit
20
Warranty: 2 years parts and labour; 5 years compressor.
See page 22 for electrical specifications, refrigerant line requirements & formulas.
HIGH WALL DUCTLESS • FLEX MULTI SPLIT
18,000-24,000 BTUs Dual Zone
27,000-36,000 BTUs Tri-Zone
Mirror Finish
ARTCOOL™ Metal Finish
Standard
12,000 BTUs Indoor Model #s:
LMA121CPM, LMA121HPM
9,000 BTUs Indoor Model #s: LMA090CP, LMA090HP
12,000 BTUs Indoor Model #s: LMA120CP, LMA120HP
9,000 BTUs Indoor Model #s: LMI090CP, LMI090HP
12,000 BTUs Indoor Model #s: LMI120CP, LMI120HP
Features:
• Changeable front color panel
option
• Multi Power System™
• R-410A Refrigerant
• Neo Plasma Air Purifying
System
• Self cleaning indoor coil
• Dehumidifying mode
• Chaos Swing
Model #
Performance
Capacity (BTUs)
Air Circulation (CFM H/M/L)
Fan Speeds
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
• Jet Cool
• Three-way cooling
• Cooling mode
• Heating mode (H/P Model only)
• Fan mode
• Auto operation
• Manual power switch
• Defrost control (H/P model only)
• Temperature display on indoor
unit
• Auto sleep mode
• Auto restart
• 24-Hour on/off timer
• Evaporator frost control
• Ultra-quiet operation
Interior Unit Includes:
• 2 Wall units
• 2 Wall unit installation plates
& hardware
• 2 Remote controls w/batteries,
2 holders & holder hardware
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging
2 indoor coils and a 25’ line
set per indoor unit
LMI090HP
LMA090HP
LMI120HP
LMA120HP
LMA121HPM
9,000/8,850
9,000/9,000
250/210/170**
4/Auto/Chaos
2.3
31/29/22
50
9,000/8,850
9,000/9,000
264/230/177**
4/Auto/Chaos
2.3
37/31/27
50
12,000/11,800
12,000/12,000
330/280/230**
4/Auto/Chaos
2.5
39/25/21
50
12,000/11,800
12,000/12,000
318/261/194**
4/Auto/Chaos
3.0
43/39/31
50
12,000/11,800
12,000/12,000
330/261/194**
4/Auto/Chaos
2.5
39/25/21
50
230/208-60-1
36V DC
33 1/16 x
10 5/8 x
6 1/32
15.4**
230/208-60-1
36V DC
22 13/32 x
22 13/32 x
5 3/8 x
24.9**
230/208-60-1
36V DC
35 3/16 x
11 x
6 1/2
20.5**
230/208-60-1
36V DC
22 13/32 x
22 13/32 x
5 3/8 x
24.9**
230/208-60-1
36V DC
36 x
11 3/32 x
6 1/2
20.5**
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
40 5/32 x
34 3/16 x
17 5/16
41 5/32 x
44 7/8 x
17 5/16
139.0
172.0
64-86/60-86
64-86/60-86
64-86/60-86
64-86/60-86
64-86/60-86
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
Dual Zone
W x H x D (inches)
Tri Zone
W x H x D (inches)
Dual Zone Weight (lbs.)
Tri Zone Weight (lbs.)
Thermostat Range
Cooling / Heating (°F)
*LG verified sound ratings
**Per indoor unit
***Exterior unit has sufficient refrigerant for charging 25’ of line set to each indoor coil
Warranty: 2 years parts and labour; 5 years compressor.
See page 22 for electrical specifications, refrigerant line requirements & formulas.
21
HIGH WALL DUCTLESS • FLEX MULTI SPLIT • DUAL & TRI ZONE
ELECTRICAL & REFRIGERATION • QUICK REFERENCE
Electrical Specifications
Zone
Type
Flex Multi Split A/C
Indoor Units
A/C
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
Outdoor Units A/C
A/C
H/P
H/P
Model
LMI090CP
LMA090CP
LMI120CP
LMA120CP
LMA121CPM
LMI090HP
LMA090HP
LMI120HP
LMA120HP
LMA121HPM
LMO240C
LMO360C
LMO240H
LMO360H
Voltage
BTUs
Indoor
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
9,000
9,000
12,000
12,000
12,000
9,000
9,000
12,000
12,000
12,000
24,000
36,000
24,000
36,000
Outdoor
—
—
—
—
—
—
—
—
—
—
230/208
230/208
230/208
230/208
Rated
Amps
0.5
1.3
0.5
1.3
0.5
0.5
1.3
0.5
1.3
0.5
11.1
16.6
11.1
16.6
MCA*
MOP**
—
—
—
—
—
—
—
—
—
—
20
20
20
20
—
—
—
—
—
—
—
—
—
—
20
30
20
30
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
All equipment single phase.
NOTE: Recommend shielded cable for low voltage wiring.
Please see local electrical codes for proper wire specifications.
Wire Size
Minimum AWG
Indoor/Outdoor Connecting Cable Shielded
14-3
18-4
Refrigerant Line & Formula Specifications***
Additional
Refrigerant
Max. length
each pipe
Max.
elevation
0.21 oz./ft.
50'
25'
3/8"
0.21 oz./ft.
50'
25'
1/4"
3/8"
0.21 oz./ft.
50'
25'
12,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
LMA121CPM
12,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
H/P
LMI090HP
9,000
1/4"
3/8 "
0.21 oz./ft.
50'
25'
H/P
LMA090HP
9,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
H/P
LMI120HP
12,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
H/P
LMA120HP
12,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
H/P
LMA121HPM
12,000
1/4"
3/8"
0.21 oz./ft.
50'
25'
Model
BTUs
LMI090CP
9,000
Pipe size
Liquid Suction
3/8"
1/4"
A/C
LMA090CP
9,000
1/4"
A/C
LMI120CP
12,000
A/C
LMA120CP
A/C
Type
Flex Multi Split A/C
***Dual Zone: exterior unit has sufficient refrigerant for charging two indoor coils and a 25 ft. line set per indoor unit.
Tri Zone: exterior unit has sufficient refrigerant for charging three indoor coils and a 25 ft. line set per indoor unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement installations) have the
following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil
trapped between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least every 12 ft.
of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above indoor unit.
22
OUTDOOR UNIT
OIL TRAP
INDOOR UNIT
25' maximum
8' minimum
12' maximum
Figure A.
Example: 25 ft. maximum elevation.
FLOOR STANDING & CEILING CASSETTE
DUCTLESS
FLOOR STANDING &
CEILING CASSETTE
AIR CONDITIONERS
High Capacity Split Systems
The floor-standing and ceiling cassette models are ideal for
light commercial applications, and work well in large, open
spaces. The ceiling cassette is a useful alternative when
floor space is limited.
Ductless Split
Floor Standing Indoor Units
White Finish
The outdoor unit for both operate on high-voltage
(230/208) power and utilize one or two compressors,
depending on the size.
Ductless Split
Ceiling Cassette Indoor Units
White Finish
28,000 BTUs
48,000 BTUs
Single Zone Split Systems
Floor Standing
24,000 BTUs
34,000 BTUs
Single Zone Split Systems
Ceiling Cassette
23
DUCTLESS FLOOR STANDING SINGLE ZONE
28,000 BTUs
LF300CP (A/C Model)
28,000 BTUs Cooling
Standard Features:
• Multi Power System™
• R-22 Refrigerant
• Chaos Swing
• Three dimensional cooling
• Jet Cool
• Cooling mode
• Dehumidifying mode
• Evaporator frost control
• 7-Hour on/off timer
• Auto restart
• Auto operation
• Plasma Air Purifying System
• Temperature display on indoor
unit
• Built-in remote control holder
System Model #
LF300CP
Indoor Model #
Outdoor Model #
LF300CPI
LF300CP0
• Control lock function
• Ultra quiet turbo fan
Interior Unit Includes:
• Floor standing unit
• Remote control and batteries
• Installation manual
Performance
Capacity (BTUs)
SEER
Air Circulation (CFM H/M/L)
Fan Speeds (Cooling/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
28,000/28,000
13
671/565/459
4/3
7.8
45/42/40
53
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
230/208-60-1
230/208
22 13/32 x
71 21/32 x
12 1/4
72.7
34 5/16 x
25 13/16 x
12 19/32
136.6
Thermostat Range
Cooling (°F)
61-86
*LG verified sound ratings
24
Warranty: 2 years parts and labour; 5 years compressor.
See page 28 for electrical specifications, refrigerant line requirements & formulas.
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
DUCTLESS FLOOR STANDING SINGLE ZONE
48,000 BTUs
LF480CE (A/C Model)
48,000 BTUs Cooling
Standard Features:
• Multi Power System™
• Chaos Swing
• Jet Cool
• Cooling mode
• Dehumidifying mode
• Fan mode
• Evaporator frost control
• 7-Hour on/off timer
• Auto restart
• Auto operation
• Temperature display on
indoor unit
• Control lock function
• Ultra quiet turbo fan
System Model #
LF480CE
Indoor Model #
Outdoor Model #
LF480CEI
LF480CEO
Interior Unit Includes:
• Floor standing unit
• Remote control and batteries
• Installation manual
Exterior Unit Includes:
• Exterior unit
• Exterior unit has sufficient
refrigerant for charging indoor
coil and a 25’ line set
Performance
Capacity (BTUs)
SEER
Air Circulation (CFM H/M/L)
Fan Speeds (Cooling/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
48,000/48,000
13
1,236/1,059/882
3/3
8.7
56/53/51
58
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
230/208-60-1
230/208
23 7/32 x
71 1/4 x
17 5/16
127.9
35 7/16 x
48 7/32 x
14 9/16
198.4
Thermostat Range
Cooling (°F)
61-86
*LG verified sound ratings
Warranty: 2 years parts and labour; 5 years compressor.
See page 28 for electrical specifications, refrigerant line requirements & formulas.
25
CEILING CASSETTE
24,000 BTUs
LC240CP (A/C Model)
24,000 BTUs Cooling
Standard Features:
• Multi Power System™
• R-410A Refrigerant
• Internal condensate pump
included
• Swirl Wind
• Four-way cooling
• Jet Cool
• Cooling mode
• Dehumidifying mode
• Fan mode
• Evaporator frost control
• 24-Hour on/off timer
• Auto restart
• Auto operation
• Plasma Air Purifying System
System Model #
LC240CP
Indoor Model #
Outdoor Model #
LC240CPI
LC240CPO
• Temperature display on remote Exterior Unit Includes:
• Ultra quiet turbo fan
• Exterior unit
• Exterior unit has sufficient
Interior Unit Includes:
refrigerant for charging indoor
• Ceiling unit
coil and a 25’ line set
• Wired control and wireless
remote control with batteries
• Installation manual
Performance
Capacity (BTUs)
SEER
Air Circulation (CFM H/M/L)
Fan Speeds (Cooling/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
24,000/23,500
13
650/600/550
5/4
6.3
38/35/32
55
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
230/208-60-1
230/208
33 1/16 x
33 1/16 x
8 7/8
57.3
34 1/4 x
31 1/2 x
12 5/8
160.0
Thermostat Range
Cooling (°F)
64-86
*LG verified sound ratings
26
Warranty: 2 years parts and labour; 5 years compressor.
See page 28 for electrical specifications, refrigerant line requirements & formulas.
CEILING CASSETTE
34,000 BTUs
LC340CP (A/C Model)
34,000 BTUs Cooling
Standard Features:
• Multi Power System™
• R-410A Refrigerant
• Internal condensate pump
included
• Swirl Wind
• Four-way cooling
• Jet Cool
• Cooling mode
• Dehumidifying mode
• Fan mode
• Evaporator frost control
• 24-Hour on/off timer
• Auto restart
• Auto operation
• Plasma Air Purifying System
System Model #
LC340CP
Indoor Model #
Outdoor Model #
LC340CPI
LC340CPO
• Temperature display on remote Exterior Unit Includes:
• Ultra quiet turbo fan
• Exterior unit
• Exterior unit has sufficient
Interior Unit Includes:
refrigerant for charging indoor
• Ceiling unit
coil and a 25’ line set
• Wired control and wireless
remote control with batteries
• Installation manual
Performance
Capacity (BTUs)
SEER
Air Circulation (CFM H/M/L)
Fan Speeds (Cooling/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
34,000/33,500
13
883/812/742
5/4
7.8
40/37/34
58
Electrical
Rated Voltage Outdoor
Rated Voltage Indoor
Indoor Dimensions
W x H x D (inches)
Weight (lbs.)
Outdoor Dimensions
W x H x D (inches)
Weight (lbs.)
230/208-60-1
230/208
33 1/16 x
33 1/16 x
8 7/8
70.4
35 7/16 x
45 7/8 x
14 9/16
57.3
Thermostat Range
Cooling (°F)
64-86
*LG verified sound ratings
Warranty: 2 years parts and labour; 5 years compressor.
See page 28 for electrical specifications, refrigerant line requirements & formulas.
27
DUCTLESS • FLOOR STANDING & CEILING CASSETTE • SINGLE ZONE
ELECTRICAL & REFRIGERATION • QUICK REFERENCE
Electrical Specifications
Type
Floor Standing
System #
Voltage
BTUs
Rated
Indoor
Outdoor
Amps
MCA*
MOP**
A/C
LF300CP
28,000
230/208
230/208
11.5/11.5
17***
25***
A/C
LF480CE
48,000
230/208
230/208
20.0/20.0
28.9***
50***
Ceiling Cassette A/C
LC240CP
24,000
230/208
230/208
11.5/12.4
17.3
30
A/C
LC340CP
34,000
230/208
230/208
15.1/16.5
27.5
50
All equipment single phase.
NOTE: Please see local electrical codes for proper wire specifications.
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
***Floor standing MCA + MOP calculated for indoor and outdoor
units connected to common breaker (Preferred method).
Wire Size
Minimum AWG
Indoor/Outdoor Connecting Cable Minimum AWG
14-3
14-3
†
Refrigerant Line Specifications
Type
System #
BTUs
Pipe size
Liquid Suction
A/C
LF300CP
28,000
3/8"
5/8"
0.32 oz./ft.
100'
66'
A/C
LF480CE
48,000
3/8"
3/4"
0.42 oz./ft.
131'
82'
Ceiling Cassette A/C
A/C
LC240CP
24,000
1/4"
1/2"
0.32 oz./ft.
100'
50'
LC340CP
34,000
1/4"
5/8"
0.42 oz./ft.
115'
66'
Floor Standing
Additional
Refrigerant
Max. length
each pipe
Max.
elevation
†Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with maximum elevation of 25 ft. (see Figure A), refrigerant lines must be oil trapped
between 8 ft. and 12 ft. of elevation.
For systems with elevation of greater than 25 ft. Refrigerant lines must be oil trapped at least
every 12 ft. of elevation.
* Each system should have a 6-8 inch inverted trap at the condensing unit if mounted above
indoor unit.
28
OUTDOOR UNIT
OIL TRAP
INDOOR UNIT
25' maximum
8' minimum
12' maximum
Figure A.
Example: 25 ft. maximum elevation.
PACKAGED TERMINAL AIR CONDITIONERS
PACKAGED TERMINAL
AIR CONDITIONERS
Ultra quiet operation is the hallmark of LG’s new line of PTAC products. Low decibel levels and outstanding sound
prevention rating make this your best choice for a quiet environment. And with efficiency ratings up to 12.7 EER,
these units are also your energy efficient choice.
Other features include standard connections for remote thermostat and front desk controls. Gold Fin™ technology
protects the unit from the corrosive effects of outside air and extends the operating life of PTAC models. And the
industry standard size makes installation easy and economical.
7,000 –15,000 BTUs
29
30
PACKAGED TERMINAL AIR CONDITIONERS
7,000-15,000 BTUs
LP070CED (H/C Model)
7,600 BTUs Cooling & Heating
LP090CED (H/C Model)
9,000 BTUs Cooling & Heating
LP120CED (H/C Model)
11,800 BTUs Cooling & Heating
LP150CED (H/C Model)
14,300 BTUs Cooling & Heating
Standard Features:
• Gold Fin™ anti-corrosion
treatment
• Cooling mode
• Heating mode
• Fan mode
• Energy saver mode
• Auto restart
• Wall thermostat temperature
control
• Front desk control connection
• Dip switch settings
• Evaporator frost control
• Temperature display on unit
• Freeze room protection
System Includes:
• Wall unit
• Installation manual
System Model #
Performance
LP070CED
LP090CED
LP120CED
LP150CED
Capacity (BTUs)
EER
Air Circulation (CFM H/L)
Fan Speeds (Cooling/Heating/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
STC
7,600/7,400
12.7
335/300
2/2/2
2.0
45/43
60/58
30
9,000/8,800
11.7
335/300
2/2/2
2.6
45/43
60/58
30
11,800/11,500
11.2
390/355
2/2/2
3.3
49/47
63/61
30
14,300/14,100
10.0
390/355
2/2/2
4.4
49/47
63/61
30
230/208-60-1
2.5
42 x
16 x
19 7/8
90.8
230/208-60-1
3.5
42 x
16 x
19 7/8
95.2
230/208-60-1
3.5
42 x
16 x
19 7/8
99.6
230/208-60-1
3.5
42 x
16 x
19 7/8
104.1
54-86/54-86
54-86/54-86
54-86/54-86
54-86/54-86
Electrical
Rated Voltage
Electric Heater (kW)
Dimensions
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling/Heating (°F)**
*LG verified sound rating
**Adjustable by temperature limiting with DIP switches on the unit
30
1-year full system warranty, parts and labor. Warranty on unit for years 2-5: parts only, exclusive of the refrigeration system.
Warranty on sealed refrigeration system: 5 year, parts and labor.
See page 31 for electrical specifications and accessories.
PACKAGED TERMINAL AIR CONDITIONERS
ACCESSORIES
Architectural Grilles
Wall Sleeve
AYSVB01A
Aluminum
AYAGALA01A
Stamped Aluminum Grille
AYRGALA01A
Dark Bronze
AYAGALB01A
Description
Model #
Sub Base 20A 230/208V
AYSB1101A
Sub Base 30A 230/208V
AYSB2101A
Control Panel Key Lock
AYCP101
Remote Escutcheon Kit - Ten Pack
AYRE110
Electrical Wall Thermostat
PYRCUCA0
Replacement Filter - 10 Pack
AYFT110
Hard Wire Kit
AYHW101
Condensate Drain Kit
AYDR101
Fuse Holder Kit
AYFH1401
Leveling Legs
AYLL101
Condensate Disposal Kit 230/208V AYCD2101
Soft Dove
AYAGALC01A
ELECTRICAL & INSTALLATION • QUICK REFERENCE
Electrical Specifications
Model #
Type
Voltage
BTUs
Rated
MCA*
MOP**
Amps
PTAC
A/C
LP070CED
7,600
230/208 - 60-1
2.7/2.9
11.3
20
A/C
LP090CED
9,000
230/208 - 60-1
3.5/3.8
13.2
20
A/C
LP120CED
11,800
230/208 - 60-1
4.8/5.2
13.2
20
A/C
LP150CED
14,300
230/208 - 60-1
6.5/7.1
13.2
20
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
NOTE: Please see local electrical codes for proper wire specifications.
Caulk
(4 sides)
Trim Molding
(if desired)
16"
Room Side
13 3/4"
16"
Outside
13 3/4"
Box and
Receptacle
42"
See page 9 for Art Cool electrical specifications, refrigerant line requirements & formulas.
31
Size
Wide plasma Filter
LG Electronics’ unique neo-plasma air-purifying system, equipped with 12-level bio-enzyme
filters, features a more enhanced sterilization power. When air passes through each level of
filters, the system can sterilize the household’s fine dust, molds, ordinary odors, and more.
New
Old
4 times larger
32
Neo Plasma Air Purifying System
LG Electronics’ unique neo-plasma air-purifying system, equipped with 12-level bio-enzyme filters,
features a much enhanced sterilization power. When air passes through each level of filters, the
system can more powerfully sterilize the household’s fine dust and molds, ordinary odors, food smells,
and cigar smoke, as well as destroy bacteria’s cell walls to completely eliminate them.
Plasma Filter
The PLASMA Air Purifying System developed uniquely by LG not only removes microscopic contaminants and dust, but also removes house mites, pollen, and
pet fur to prevent allergic diseases like asthma.
What is Nano Carbon Ball?
Nano(1/1Bil) ball structure,consisted of
Nano carbon, is adopted
as deodorizing material first in the world
Kitasato Research Center of Environmental Sciences
- Inactivating Germs Test Result 99.9% Performance (No. 16_0113_1,2,3)
Japan Food Research Laboratories
- Inactivating Germs Test Result 99.9% Performance (No. 104093863-001,2,3,4,5)
- Killing Virus (No. 204031236-001,2,3)
200~500nm
Japan Spinners Inspecting Foundation (No. 624217, 019355-13)
- NCB Deodorizing 4 Type Test Result 78%~98% Security
FITI Korea Consumer Science Center (No. 513104-195-A-01)
- Killing bacteria, fungi Test Result 99.9% Security
ITS(International Technical Standard Center) (No. IL26937-A,B)
- Inactivating bacteria Test Result 99.9% Security
Nano Bio Fusion Filter
Nano bio fusion filters allow their nano-size bio enzymes to directly penetrate through cell walls of bacteria and allergen to decompose its cell
nuclei and kill them.While conventional fillters merely inactivate bacteria or destroy external cell walls, this innovative sterilization technology can
completely decompose bacteria’s cell nuclei and kill them.
Bio Active Site
Active State
Bacteria, Virus
Bacteria Selective
Capture
Bacteriolysis
Distinctions from Conventional Filters
Nano Particle
Regeneration
(Active State)
Conventional
Nano Bio Fusion Filter
Simply inactivate
Destroy bacteria but allow part
The bio enzyme destroys cell
bacteria
of them to survive
walls and nuclei of bacteria
and allergens, thus completely
kills bacteria
Download PDF

advertising