Commander 400
For use with machine code numbers: 9978, 9979, 10580, 10581
SVM133-B
September, 2002
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation . . .
and thoughtful operation on your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
SERVICE MANUAL
Copyright © 2002 Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
The Above For Diesel Engines
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
i
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
ELECTRIC AND
MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
____________________________________________________
1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete.
Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.1. Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95
COMMANDER 400
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
SAFETY
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Head shield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone. When welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.
5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95 ii
COMMANDER 400
iii
WELDING SPARKS can cause fire or explosion.
6.a. Remove fire hazards from the welding area.
If this is not possible, cover them to prevent the welding sparks from starting a fire.
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended
Safe Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits.
This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
SAFETY
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to physical damage.
• A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
iii
Mar ‘95
COMMANDER 400
iv
SAFETY zones où l’on pique le laitier.
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: iv
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique: a. Les circuits à l’électrode et à la piéce sont sous tension quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le refroidir.
e. Ne jamais toucher simultanément les parties sous tension des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits
éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de levage, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard
W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
a. Utiliser un bon masque avec un verre filtrant approprié ainsi qu’un verre blanc afin de se protéger les yeux du rayonnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au soudage à l’aide d’écrans appropriés et non-inflammables.
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pantalons sans revers, et chaussures montantes.
3. Avant de faires des travaux à l’interieur de poste, la debrancher à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les
COMMANDER 400
Mar. ‘93
v
MASTER TABLE OF CONTENTS FOR ALL SECTIONS
RETURN TO MAIN INDEX
Page
v
Parts Manual......................................................................................................................P267 Series
COMMANDER 400
Section A-1
TABLE OF CONTENTS
- INSTALLATION SECTION -
Installation
Section A-1
COMMANDER 400
A-2
INSTALLATION
TECHNICAL SPECIFICATIONS - Commander 400
Make/Model
Deutz
F3L 912 Diesel
Engine
Description
INPUT - DIESEL ENGINE
Speed (RPM) Displacement Starting
System
3 cylinder High Idle 1900
44.2 HP(33kw) Low Idle 1350
@ 1800 RPM Full Load 1800
Capacities
173 cu. in
(2.827 L)
Bore x Stroke
3.94” x 4.72”
(100mm x 120mm)
12VDC battery Fuel: 25 gal.
& Starter 94.6 L
Oil: 8.5 Qts.
8.04 L
Duty Cycle
100%
60%
RATED OUTPUT - WELDER
Welding Output
400 amps (DC Constant Current)
400 amps (DC Constant Voltage)
Volts at Rated Amps
40 volts
40 volts
500 amps (DC Constant Current)
500 amps (DC Constant Voltage)
40 volts
40 volts
OUTPUT - WELDER AND GENERATOR
Open Circuit Voltage Auxiliary Power 1 Welding Range
40 - 575 Amps in 7 Ranges (Stick model)
64-74 OCV or 8 Ranges (Stick & Wire model) @1915 RPM
120/240 VAC
10,000 Watts, 60 Hz.
100% Duty Cycle
HEIGHT 2
42.0 in.
1066.8 mm
WIDTH
PHYSICAL DIMENSIONS
DEPTH
31.5 in.
800.1 mm
63.1 in.
1602.7 mm
WEIGHT
1650 lbs.(748 kg)
(Stick model)
1683 lbs.(763 kg)
(Stick & Wire model)
A-2
1. Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2. Top of Enclosure. Add 6.64” (168.7mm) for exhaust.
COMMANDER 400
A-3 A-3
INSTALLATION
Read this entire installation section before you start installation.
SAFETY PRECAUTIONS
WARNING
Do not attempt to use this equipment until you have thoroughly read all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating and maintenance instructions and parts lists.
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such as output terminals or internal wiring.
• Insulate yourself from the work and ground.
gloves.
LOCATION AND VENTILATION
The welder should be located to provide an unrestricted flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are properly vented to an outside area.
STORING
1. Store the machine in a cool, dry place when it is not in use. Protect it from dust and dirt. Keep it where it can’t be accidentally damaged from construction activities, moving vehicles, and other hazards.
2. Drain the engine oil and refill with fresh 10W30 oil.
Run the engine for about five minutes to circulate oil
to all the parts. See the Maintenance section of
this manual for details on changing oil.
3. Remove the battery, recharge it, and adjust the electrolyte level. Store the battery in a dry, dark place.
4. See your engine operation manual for further information on fuel and engine preservation.
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or vent exhaust outside.
• Do not stack anything near the engine.
STACKING
Commander 400 machines CANNOT be stacked.
MOVING PARTS can injure.
• Do not operate with doors open or guards off.
• Stop the engine before servicing.
• Keep away from moving parts.
ANGLE OF OPERATION
To achieve optimum engine performance the
Commander 400 should be run in a level position. The maximum angle of operation for the Deutz engine is 20 degrees in a direction to cause the control panel to be angled up, 30 degrees for side to side tilting and for the control panel to be angled down. If the engine is to be operated at an angle, provisions must be made for checking and maintaining the oil level at the normal
(FULL) oil capacity in the crankcase. When operating the welder at an angle, the effective fuel capacity will be slightly less than the specified 25 gallons.
See additional safety information at the front of this manual.
Only qualified personnel should install, use, or service this equipment.
COMMANDER 400
A-4 A-4
INSTALLATION
LIFTING
The Commander 400 weights 1650 lb./748 kg (Stick model); 1683 lb./763 kg. (Stick & Wire model). A lift bail is provided for lifting with a hoist.
WARNING
FALLING EQUIPMENT can cause injury.
Do not lift this machine using lift bail if it is equipped with a heavy accessory such as a trailer.
Lift only with equipment of adequate lifting capacity. Be sure machine is stable when lifting.
3. Proper placement of the equipment on the trailer to insure stability side to side and front to back when the trailer is being moved and when standing by itself.
4. Typical conditions of use, such as travel speed, roughness of surface on which the trailer will be operated, environmental conditions, and likely maintenance.
5. Proper preventative maintenance of trailer.
6. Conformance with federal, state and local laws.
1
1 Consult applicable federal, state and local laws regarding specific requirements for use on public highways.
The Commander is shipped with the lift bail retracted.
Before attempting to lift the Commander, secure the lift bail in a raised position. Secure the lift bail as follows: a. Open the engine compartment door.
b. Locate the 2 access holes on the upper middle region of compartment wall just below the lift bail.
c.
Use the lifting strap to raise the lift bail to the full upright position. This will align the mounting holes on the lift bail with the access holes.
d. Secure the lift bail with 2 thread forming screws.
The screws are provided in the shipped loose parts bag.
PRE-OPERATION ENGINE SERVICE
Read and understand the information about the diesel
engine in the Operation and Maintenance sections of
this manual before you operate the Commander 400.
WARNING
• Stop the engine and allow it to cool before fueling.
• Do not smoke when fueling.
• Fill the fuel tank at a moderate rate and do not overfill.
• Wipe up spilled fuel and allow the fumes to clear before starting the engine.
• Keep sparks and flame away from the tank.
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary.
Some engine adjustments may be required. Contact a
Deutz Service Representative.
TOWING
The recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle(1) is
Lincoln’s K953-1. If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment. Some of the factors to consider are as follows:
1. Design capacity of trailer vs. the weight of the
Lincoln equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of the welding equipment so that there will be no undue stress to the trailer’s framework.
COMMANDER 400
OIL
The Commander 400 is shipped with the engine filled with SAE 10W-30 oil (API class CD or better). This should be fine for most ambient operating temperature conditions. See the engine operation manual for specific recommendations. CHECK THE OIL LEVEL
BEFORE YOU START THE ENGINE.
This is an added precaution. When full, the oil level should be up to but not over the FULL mark on the dipstick. If it is not full, add enough oil to fill it to the full mark. DO NOT overfill.
Check oil level after every 4 hours of running time during the first 35 hours of operation.
NOTE: This machine is equipped with an engine protection package. An internal kill switch will shut down the engine if the oil pressure drops below a minimum level or if oil temperature becomes excessive.
For more oil fill and service information, see the
Maintenance section of this manual.
A-5 A-5
INSTALLATION
FUEL
BATTERY CONNECTIONS
WARNING
NOTE: Use diesel fuel only.
Fill the fuel tank with clean, fresh diesel fuel. The capacity of the fuel tank is 25 gallons (94.6 liters). See
the Operation and Maintenance sections of this man-
ual for more details about fuel.
The Commander 400 is protected by a low fuel shutdown to prevent the engine from running out of fuel. The machine will indicate a low fuel condition by turning on the low fuel light. A time of 30 minutes will elapse once the low fuel light illuminates before the machine will shutdown. A restart of the machine will restart the timer to allow the operator to override this feature. The amount of reserve fuel remaining in the tank after the first shutdown will vary from machine to machine. The operator must determine the amount of fuel remaining before re-starting the machine.
Running out of fuel may require bleeding the fuel injection pump.
NOTE: Before starting the engine, open the fuel shutoff valve (lever to be in line with hose) located on the side of the fuel pre-filter/water separator housing.
BATTERY ACID CAN BURN EYES AND
SKIN.
• Wear gloves and eye protection and be careful when working near a battery, follow the instructions printed on the battery.
– +
The Commander 400 is shipped with the negative battery cable disconnected.
Before you operate the machine, make sure the IGNI-
TION switch is in the OFF position and attach the disconnected cable securely to the battery terminal. If the battery is discharged and won't start the engine, see
the battery charging instructions in the Maintenance
section.
MUFFLER OUTLET PIPE
Remove the plastic plug covering the muffler outlet tube. Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction.
FUEL CAP
Remove the plastic cap covering the fuel tank filler neck and install the fuel cap.
COOLING SYSTEM
The Deutz engine is air cooled by a belt driven axial blower. The oil cooler and engine cooling fins should be blown out with compressed air or steam to maintain proper cooling (See the engine owner’s manual for procedures and frequency).
SPARK ARRESTER
Diesel engine mufflers may emit sparks when the engine is running. Some federal, state, or local laws require spark arresters in locations where unarrested sparks could present a fire hazard.
Standard mufflers (like the one included with the
Commander 400) do not act as spark arresters. When local laws require it, a spark arrester must be installed on the machine and properly maintained. An optional spark arrester kit is available for your Commander 400.
See the Accessories section of this manual for more
information.
CAUTION
An incorrect arrester may lead to damage to the engine or adversely affect performance.
COMMANDER 400
A-6 A-6
INSTALLATION
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.1 for the location of the 120 and 240 volt receptacles, weld output terminals, and ground stud.
CAUTION
• Loose connections will cause the output terminals to overheat. The terminals may eventually melt.
• Do not cross the welding cables at the output terminal connection. Keep the cables isolated and separate from one another.
WELDING CABLE CONNECTIONS
CABLE INSTALLATION AND CABLE SIZES
With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the terminals located on the fuel tank mounting rail. (See size recommendations below.) For positive polarity, connect the electrode cable to the terminal marked Positive (+). For Negative polarity, connect the electrode cable to the Negative (-) terminal. These connections should be checked periodically and tightened if necessary.
When welding at a considerable distance from the welder, be sure you use ample size welding cables.
Table A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length refers to the distance from the welder to the work and back to the welder. Cable diameters are increased for long cable lengths to reduce voltage drops.
Lincoln Electric offers a welding accessory kit with the properly specified welding cables. See the
Accessories section of this manual for more
information.
FIGURE A.1 - COMMANDER 400 OUTPUT CONNECTIONS
FUEL TEMP
OIL
PRESS AMPS
0 0 0 0 0
H O U R S
0
1 2 0 V O LT
R E C E P TA C L E S
C V W O R K -
W E L D O U T P U T
T E R M I N A L
+
-
-
2 4 0 V O LT R E C E P TA C L E
G R O U N D S T U D
W E L D O U T P U T T E R M I N A L S
( E L E C T R O D E + & C C W O R K - )
Amps
250
400
TABLE A.1 - RECOMMENDED COPPER WELDING CABLE SIZE AND LENGTH
TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES
Cable sizes for combined length of electrode plus work cable
Duty Cycle
100%
100%
Up to 200 ft.
1 AWG
3/0 AWG
200 to 250 ft.
1/0 AWG
4/0 AWG
COMMANDER 400
A-7 A-7
INSTALLATION
MACHINE GROUNDING
Because this portable engine driven welder creates its own power, it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (home, shop, etc.).
To prevent dangerous electric shock, other equipment powered by this engine driven welder must: a) be grounded to the frame of the welder using a grounded type plug, or b) be double insulated.
When this welder is mounted on a truck or trailer, its frame must be securely connected to the metal frame of the vehicle. When connected to premises wiring such as that in a home or shop, its frame must be connected to the system earth ground. See further connection instructions in the section “Standby Power
Connections” as well as the article on grounding in the latest U.S. National Electrical Code and the local code.
In general, if the machine is to be grounded, it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulated joints or to the metal framework of a building that has been effectively grounded. The U.S National Electrical
Code lists a number of alternate means of grounding electrical equipment. A machine grounding stud marked with the symbol is provided on the front of the welder.
AUXILIARY POWER RECEPTACLES
The Commander 400 can produce 10,000 watts of 60
Hz, single-phase auxiliary power. (The rating in watts is equivalent to volt-amperes at unity power factor.)
The output voltage is within ±10% at all loads up to the rated capacity.
The following receptacles are provided:
• Two 15 amp-120VAC duplex GFCI receptacles
(5-15R)
• One 50 amp-120/240VAC receptacle (14-50R)
The 50 amp receptacle has a maximum permissible output of 44 amps. However, it can be split to power two separate, single-phase 120VAC branch circuits each capable of 44 amps output.
NOTE: The two 120VAC outlets of the 120/240VAC receptacle cannot be paralleled. They are on two different phases.
The auxiliary power receptacles should be used with only three-wire, grounded type plugs or approved double-insulated tools with two-wire plugs. The current rating of any plug used with the system must be at least equal to the current-carrying capacity of the associated receptacle. An optional power plug kit is available.
STANDBY POWER CONNECTIONS
The Commander 400 is suitable for temporary, standby or emergency power using the engine manufacturer’s recommended maintenance schedule.
The Commander 400 can be permanently installed as a standby power unit for 240 volt 3-wire, 44 ampere service. Connections must be made by a licensed electrician who can determine how the 120/240 VAC power can be adapted to the particular installation and comply with all applicable electrical codes. The following information can be used as a guide by the electrician for most applications. Refer to the connection
1. Install the double-pole, double-throw switch between the power company meter and the premises disconnect.
The switch rating must be the same or greater than the customer’s premises disconnect and service over current protection.
2. Take the necessary steps to assure the load is limited to the capacity of the Commander 400 by installing a 45 amp, 240 VAC double-pole circuit breaker. Maximum rated load for each leg of the 240
VAC auxiliary is 45 amperes. Loading above the rated output will reduce output voltage below the allowable -10% of rated voltage, which may damage appliances or other motor-driven equipment and may result in overheating of the Commander 400 engine.
3. Install a 50 amp 120/240 VAC plug (NEMA Type 14-
50) to the double-pole circuit breaker using No. 6, 4 conductor cable of the desired length. (The 50 amp,
120/240 VAC plug is available in the optional K802R
plug kit.) See the Accessories section.
4. Plug this cable into the 50 ampere 120/240 volt receptacle on the Commander 400 case front.
COMMANDER 400
A-8
240 Volt
60 Hz.
3-Wire
Service
INSTALLATION
FIGURE A.2 - CONNECTION OF THE COMMANDER 400 TO PREMISES WIRING
A-8
POWER
COMPANY
METER
240 VOLT
120 VOLT
120 VOLT
GROUNDED CONDUCTOR
NEUTRAL
BUS
N
LOAD
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
GROUND
PREMISES
DISCONNECT AND
SERVICE
OVERCURRENT
PROTECTION
50 AMP, 120/240
VOLT PLUG
NEMA TYPE 14-50
240 VOLT
45AMP
240 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
GND
50 AMP, 120/240 VOLT
RECEPTACLE
N
NOTE: No. 6 COPPER CONDUCTOR CABLE.
SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE
WIRE SIZE RECOMMENDATIONS.
COMMANDER 400
Section B-1
TABLE OF CONTENTS
- OPERATION SECTION -
Operation ...............................................................................................................................
Section B
Commander 400 Settings With K799 Hi-Freq./K930-1 Tig Module....................................B-11
Section B-1
COMMANDER 400
B-2 B-2
OPERATION
OPERATING INSTRUCTIONS
Read and understand this entire section before operating your Commander 400.
SAFETY INSTRUCTIONS
WARNING
WARNING
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or vent exhaust to the outside.
• Do not stack anything on or near the engine.
Do not attempt to use this equipment until you have thoroughly read all the operating and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating and maintenance instructions and parts lists.
MOVING PARTS can injure.
• Do not operate this equipment with any of its doors open or guards off.
• Stop the engine before servicing it.
• Keep away from moving parts.
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrodes with your skin or wet clothing.
• Insulate yourself from the work and ground.
• Always wear dry insulating gloves.
Only qualified personnel should install, use, or service this equipment.
FUMES AND GASES can be dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove fumes from breathing zone.
WELDING SPARKS can cause fire or explosion.
• Keep flammable material away.
• Do not weld on containers that have held combustibles.
GENERAL DESCRIPTION
The Commander 400 is a diesel engine driven welding power source. The machine uses a brushless asynchronous alternating current generator for DC stick electrode welding and for 120/240 VAC auxiliary standby power. As a generator it can supply up to
10,000 watts of 120/240 volt AC power. As a welder it provides up to 400 amps of DC constant current output in six slope-controlled ranges. In addition a seventh general purpose welding range provides up to 575 amps of constant current welding output.
The engine is a 44.2 Hp (33kw), 3-cylinder air/oil cooled diesel made by Deutz. This naturally aspirated,
4 cycle engine features direct injection, a Bosch in-line injection pump and a Bosch mechanical governor.
This machine is controlled by a high quality microcontroller. The microcontroller provides high speed control of the weld process as well as the engine protection features.
ARC RAYS can burn.
• Wear eye, ear, and body protection.
COMMANDER 400
B-3
OPERATION
RECOMMENDED APPLICATIONS
WELDER
The Commander 400 (Stick model) provides excellent constant current DC welding output for stick (SMAW) welding. The Commander 400 (Stick & Wire model) also provides excellent constant voltage DC welding output for MIG (GMAW) and Inner shield (FCAW) welding.
GENERATOR
The Commander 400 provides smooth 120/240 VAC output for auxiliary power and emergency standby power.
B-3
• One 50 amp, 120/240 VAC dual voltage receptacle for up to 44 amps of 240 VAC, and up to 44 amps per side to separate branch circuits (not in parallel) of 120
VAC single phase auxiliary power. Allows easy connection to premises wiring.
• Weld and AC auxiliary power at the same time (within machine total capacity).
OTHER FEATURES
DESIGN FEATURES
(All Models)
FOR STICK WELDING
• Excellent DC constant current output for stick welding applications.
• 40 to 400 amps output in six slope controlled ranges for out-of position and pipe electrodes; 50 to 575 amps constant current output in one general purpose welding range.
• 3 digit display is provided for presetting the weld amperage and displaying the actual amperage during welding. The display uses super brite LEDs for improved readability in full sunlight.
• Remote control capability standard on all models.
• Selection of “hot” or “cold” output terminals with a toggle switch on the control panel. This feature can also be controlled by installing a remote output terminal control cable designed to open and close the #2 and
#4 leads in the amphenol receptacle.
Designed for long life, easy maintenance and excellent fuel economy.
• Engine protection system shuts the engine down for low oil pressure, high oil temperature or a broken fan/engine alternator belt.
• Gauges for oil pressure, oil temperature, engine alternator output and fuel level.
• Indicator lights for low oil pressure, high oil temperature, engine alternator low output/broken belt and low fuel level.
• Automatic low fuel shutdown before running out of fuel.
• Engine hour meter standard on all models.
• Extended range 25 gallon (94.6 l) fuel tank.
• Fuel pre-filter/water separator with “dry” change element.
• Automatic idler reduces engine speed when not welding or drawing auxiliary power. This feature reduces fuel consumption and extends engine life.
• Single side engine service with over the top access to the engine.
• Copper alternator windings and high temperature insulation for dependability and long life.
FOR AUXILIARY POWER
• 10,000 watts of 120/240 VAC, 60Hz auxiliary power.
• Will drive a 2 HP motor (provided it is started under no load).
• Two 15 amp 120 VAC duplex receptacles with GFCI protection for up to 30 amps of 120 VAC power.
COMMANDER 400
B-4 B-4
OPERATION
ADDITIONAL DESIGN FEATURES
(Stick & Wire Model only)
FOR WIRE WELDING
• One constant voltage position for all wire welding. A
12 to 45V range across the entire current output range.
• Excellent arc characteristics with MIG (GMAW) and
Inner shield (FCAW) welding.
• A Wire Feeder connector for quick connection of the control cable.
• A built in “Electronic Contactor” for “Cold” electrode when not welding.
• The 3 digit display has the additional feature of presetting the open circuit voltage and displaying the actual voltage during welding.
• Designed for use with the following Lincoln wire feeders.
•LN-25
•LN-8
•LN-23P
•NA-3
•LN-7
•Spool Gun &
K488 Module
WELDING CAPABILITY
The Commander 400 is rated at 400 amps, 40 volts at
100% duty cycle. The weld current is variable from 40 to 575 amps.
COMMANDER 400
B-5
OPERATION
CONTROLS AND SETTINGS
The welder/generator controls are located on the case front panel. Refer to Figure B.1 and the explanations that follow.
FIGURE B.1 – CASE FRONT PANEL CONTROLS
1 2 3 4 5 6 7 8
B-5
1 0
1 7
2 3
9
FUEL TEMP
OIL
PRESS
-
AMPS
0 0 0 0 0
H O U R S
0
9
11
1 2
1 3
2 2
2 1
2 4
2 0
+ -
1 8
1 5 1 6
1 9
1 4
ENGINE CONTROLS
(Figure B.1, Items 1 through 8)
See Figure B.1 for the location of the following features:
1. RUN-STOP SWITCH: When placed in the “RUN” position, this switch energizes the fuel solenoid and other electric accessories. When placed in the
“STOP” position, the flow of fuel to the injection pump is stopped to shut down the engine.
NOTE: If the switch is left in the “RUN” position and the engine is not running, the battery will be drained by the fuel solenoid.
2. START PUSHBUTTON: Energizes the starter motor to crank the engine. With the engine RUN-
STOP switch in the “RUN” position, push and hold the START button for a minimum of 2 seconds to crank the engine; release as the engine starts. Do not press while engine is running since this can cause damage to the ring gear and/or starter motor.
COMMANDER 400
3. FUEL LEVEL GAUGE AND LIGHT: Displays the level of diesel fuel in the 25-gallon (94.6 liter) fuel tank. The yellow light turns on when the fuel gage reaches the reserve level. Once the reserve level is reached, the engine protection system will shut down the engine after 30 minutes of operation. The machine can be restarted and operated for an additional 30 minutes before the protection system will shut down the engine. This ability to override the engine protection is to allow the operator to “finish up” if necessary. The operator must watch the fuel level closely to prevent running out of fuel and having to bleed the system.
B-6 B-6
OPERATION
4. ENGINE TEMPERATURE GAUGE AND LIGHT:
The gauge displays the engine oil temperature. The yellow temperature light remains off under normal operating temperatures. If the light turns on, the engine protection system will shut down the engine.
Check for restrictions at the engine cooling air inlets and outlets (consult the engine Operation manual).
Check for loose or disconnected leads at the temperature sender located on the engine. Check engine cooling blower belt. Also, check to be sure that the welder loads are within the rating of the welder. The light will remain on when the engine has been shut down due to an over- temperature condition.
5. OIL PRESSURE GAUGE AND LIGHT: The gauge displays the engine oil pressure when the engine is running. The yellow oil pressure light remains off with proper oil pressure. If the light turns on, the engine protection system will stop the engine.
Check for proper oil level and add oil if necessary.
Check for loose or disconnected leads at the oil pressure sender located on the engine. The light will go on and stay on when the RUN-STOP switch is switched to the “RUN” position with the engine not running.
6. ENGINE ALTERNATOR AMMETER AND LIGHT:
The yellow engine alternator light is off when the battery charging system is functioning normally. If the light turns on, the engine protection system will shut down the engine. Check the engine cooling blower belt. Also, the alternator or the voltage regulator may not be operating correctly. The light may also come on if the alternator did not flash up due to not holding the start button in long enough (minimum of 2 seconds) or due to a faulty flashing circuit.
The light will remain on when the engine has been shut down due to a fault in the alternator, regulator, or the cooling blower belt.
7. IDLER SWITCH: Adjusts the running speed of the engine. Has two positions as follows:
A) In the “High” position, the engine runs at the high idle speed controlled by the governor.
B) In the “Auto” position, the idler operates as follows: a. When switched from “HIGH” to “AUTO” or after starting the engine, the engine will operate at full speed for approximately 15 seconds and then go to low idle speed.
b. When the electrode touches the work or power is drawn for lights or tools (approximately 100 Watts minimum), the engine accelerates and operates at full speed. c. When welding ceases or the AC power load is turned off, a fixed time delay of approximately 15 seconds starts.
d. If the welding or AC power load is not restarted before the end of the time delay, the idler reduces the engine speed to low idle speed.
e. The engine will automatically return to high idle speed when the welding load or AC power load is reapplied.
Idler Operational Exceptions
When the WELDING TERMINALS switch is in the
“WELDING TERMINALS REMOTELY CONTROLLED” position, the idler will operate as follows: a. When the triggering device (Amptrol, Arc Start
Switch, etc.) is pressed, the engine will accelerate and operate at full speed provided a welding load is applied within approximately 15 seconds.
• If the triggering device remains pressed but no welding load is applied, within approximately 15 seconds the engine will return to low idle speed.
• If the triggering device is released or welding ceases, the engine will return to low idle speed after approximately 15 seconds.
8. HOUR METER: The hour meter displays the total time that the engine has been running. This meter is a useful indicator for scheduling preventive maintenance.
COMMANDER 400
B-7
OPERATION
WELDER CONTROLS
through 14 )
9. OUTPUT RANGE SWITCH AND OUTPUT CON-
TROL: These two controls allow you to select between various welding output slopes and adjust the desired welding output. Refer to Table B.1 for a description of how these two controls work.
TABLE B.1 OUTPUT RANGE SWITCH AND OUT-
PUT CONTROL FUNCTIONS
Range
Switch
1
Control
Sloped Output for
Pipe Welding.
(all models)
6 Range
Settings
90, 120, 180,
230, 270, 400
(Max. current on each setting)
Constant Current
Output for
Fabrication and
General Purpose
Welding (This setting also used for
TIG) (all models)
1 Range setting
50-575 Amps
Provides a fine adjustment of welding current or voltage from
Min (1) to Max
(10) within each range
Constant Voltage
Output for Wire
Welding (Stick &
Wire model only)
1 Range setting
12 to 40 Volts
2
1 If the OUTPUT RANGE switch is positioned between settings, the previous setting is maintained until the switch is properly positioned on a setting.
2 The OUTPUT CONTROL also controls O.C.V. while in the 6 sloped output ranges.
B-7
With the switch in the “WELDING TERMINALS
ALWAYS ON” position, the contactor is closed and the welding terminals are always “Hot.”
With the switch in the “WELDING TERMINALS
REMOTELY CONTROLLED” position, the contactor operation is controlled by an Amptrol, Arc Start
Switch or some other type of triggering device through the use of a control cable connected to the 6-pin MS connector.
When the triggering device is pressed the contactor is closed and the welding terminals are “Hot.”
When the triggering device is released the contactor is opened and the welding terminals are
“Cold.”
12. LOCAL/REMOTE SWITCH: The toggle switch on the control panel labeled “LOCAL/REMOTE” gives you the option of controlling the output at the welder control panel or at a remote location.
For remote control, set the toggle switch in the
“REMOTE” position.
For control at the welder control panel, set the toggle switch in the “LOCAL” position.
13. 6 - PIN CONNECTOR: The 6-pin connector located on the control panel allows for connection of
Remote Control accessories.
14. WELD OUTPUT TERMINALS + AND - : These
1/2 - 13 studs with flange nuts provide welding connection points for the electrode and work cables. For positive polarity welding, the electrode cable connects to the “+” terminal and the work cable connects to the “-” terminal. For negative polarity welding, the work cable connects to the
“+” terminal and the electrode cable connects to the “-” terminal.
10. DIGITAL OUTPUT METER: The digital output meter is located in the center of the control panel between the two large control knobs. The meter allows the output current level to be set prior to welding. During the welding process the meter displays the actual output current.
11. WELDING TERMINALS SWITCH: The toggle switch on the control panel labeled “WELDING
TERMINALS ALWAYS ON” and “WELDING TER-
MINALS REMOTELY CONTROLLED,” is used to control the operation of the “solid state contactor,” which allows for the selection of “Hot” or “Cold” welding terminals.
COMMANDER 400
B-8 B-8
OPERATION
AUXILIARY POWER CONTROLS
15. 120/240VAC RECEPTACLE: This is a 120/240VAC
(14-50R) receptacle that provides 240VAC or can be split for 120VAC single phase auxiliary power.
The receptacle has a 50 amp rating. Refer to
in the
Installation section for further information about
this receptacle. Also refer to “Auxiliary Power
Operation” later in this section.
16. 50 AMP CIRCUIT BREAKERS: These circuit breaker provide separate overload current protection for each 120V circuit at the 240V receptacle.
17. 120VAC RECEPTACLES: These two 120VAC (5-
15R) receptacles with GFCI protection provide
120VAC for auxiliary power. The receptacles have
a 20 amp total rating. Refer to “Auxiliary Power
Receptacles” in the Installation section for fur-
ther information about these receptacles. Also
refer to “Auxiliary Power Operation” later in this
section.
18. 15 AMP CIRCUIT BREAKERS: These circuit breakers provide separate overload current protection for each 120V receptacle.
19. GROUND STUD: Provides a point for connecting the machine case to earth ground for the safest
grounding procedure. Refer to “Machine
Grounding” in the Installation section for proper
machine grounding information.
ENGINE OPERATION
STARTING THE ENGINE
1. Open the engine compartment door and check that the fuel shutoff valve located to the left of the fuel filter housing is in the open position (lever in line with the hose).
2. Check for proper oil level on the oil dipstick. Close engine compartment door.
3. Remove all plugs connected to the AC power receptacles.
4. Set the IDLER switch to “AUTO.”
5. Set the RUN/STOP switch to “RUN.” Observe that all engine protection lights momentarily turn on.
Some lights may turn off before starting. Check the fuel gauge to make sure that there is an adequate fuel level.
6. Press and hold the engine START button for a minimum of 2 seconds.
7. Release the engine START button when the engine starts.
8. Check that the indicator lights are off. If the LOW
FUEL light is on , the engine will shut down 30 minutes after starting. If any other indicator light is on after starting, the engine will shut down in a few seconds. Investigate any indicated problem.
9. Allow the engine to warm up at low idle speed for several minutes before applying a load and/or switching to high idle. Allow a longer warm up time in cold weather.
WIRE FEEDER MODE CONTROLS
(Figure B.1 Items 20 - 24 Stick & Wire model only)
20. WELD OUTPUT TERMINAL - WIRE: This 1/2-13 stud with flange nut provides a welding connection point for the electrode or work cables. For positive polarity welding, the electrode cable connects to the “+” terminal and the work cable connects to the
“-” terminal. For negative polarity welding, the work cable connects to the “+” terminal and the electrode cable connects to the “-” terminal.
21. 15 AMP CIRCUIT BREAKER: This circuit breaker provides overload protection for the 14-pin connector.
22. VOLTMETER +/- SWITCH: Changes the polarity display on the wire feeder.
23. VOLTS-AMPS SWITCH: Switches the display between volts and amps.
24. 14 - PIN CONNECTOR: For quick connection of wire feeder control cable.
COLD WEATHER STARTING
With a fully charged battery and the proper weight oil, the engine should start satisfactorily even down to about 0 o F.
If the engine must be frequently started below 10 o F, it may be desirable to install the optional Ether Start kit
(K825-1). Installation and operating instructions are included in the kit. Use ether starting only when required, because excessive use shortens engine life.
COMMANDER 400
B-9 B-9
OPERATION
STOPPING THE ENGINE
1. Switch the RUN/STOP switch to “STOP.” This turns off the voltage supplied to the shut down solenoid. A backup shut down can be accomplished by shutting off the fuel valve located on the fuel filter housing.
TYPICAL FUEL CONSUMPTION
Refer to Table B.2 for typical fuel consumption of the
Commander 400 engine for various operating scenarios.
Table B.2 Deutz F3L 912 Engine Fuel Consumption
BREAK-IN PERIOD
The engine used to supply power for your welder is a heavy duty, industrial engine. It is designed and built for rugged use. It is very normal for any engine to use small quantities of oil until the break-in is accomplished. Check the oil level twice a day during the break-in period (about 200 running hours).
CAUTION
During break-in, subject the Commander 400 to heavy loads. Avoid long periods running at idle. Before stopping the engine, remove all loads and allow the engine to cool several minutes.
Deutz F3L 912
44.2 Hp
@ 1800 RPM
Running Time for
25 gallons
(Hours)
Low Idle - No
Load 1350 RPM
.30 gallons/hour
(1.36 liters/hour)
High Idle - No
Load 1900 RPM
.78 gallons/hour
( 3.55 liters/hour)
DC CC Weld
Output 400
Amps @ 40
Volts
Auxiliary Power
10,000 VA
1.84 gallons/hour
( 8.36 liters/hour)
1.32 gallons/hour
(6.00 liters/hour)
83.3
32.1
13.6
18.9
The heavy loading of the engine during break-in, within the rating of the machine, is recommended to properly seat the piston rings and prevent wetstacking.
Wetstacking is an accumulation of unburned fuel and/or lubricant in the form of a wet, black, tar-like substance in the exhaust pipe. The rings are seated and the break-in period is complete when there are no longer any signs of wetstacking, which should occur within the first 50 to 100 hours of operation.
CAUTION
Using your welder at low amperages with long idle running periods during the break-in period may result in a glaze forming on the engine cylinder walls and the rings not seating properly. No amount of loading will properly seat the piston rings after they are glazed over.
COMMANDER 400
B-10 B-10
OPERATION
WELDER OPERATION
STICK WELDING
The Commander 400 can be used with a broad range of DC stick electrodes.
The OUTPUT RANGE switch provides six overlapping slope controlled current ranges. The OUTPUT CON-
TROL adjusts the current from minimum to maximum within each range. Open circuit voltage is also controlled by the OUTPUT CONTROL in the slope controlled setting. These slope controlled settings are intended for “out-of-position” welding, including pipe welding, where the operator would like to control the current level by changing the arc length.
PIPE WELDING
When using a sloped range, a high open circuit voltage setting provides the softest arc with best resistance to pop-outs. To get this characteristic, set the OUTPUT
RANGE switch to the lowest setting that still provides the current you need and set the OUTPUT CONTROL near maximum. For example: to obtain 175 amps and a soft arc, set the OUTPUT RANGE switch to the “180
MAX” position and then adjust the OUTPUT CON-
TROL for 175 amps.
When a forceful “digging” arc is required, use a higher setting and lower open circuit voltage. For example: to obtain 175 amps and a forceful arc, set the OUTPUT
RANGE switch to the “230 MAX” position and then adjust the OUTPUT CONTROL to get 175 amps.
GENERAL WELDING
The seventh position of the OUTPUT RANGE switch is designed for horizontal welds with all types of electrodes, especially low hydrogen. The OUTPUT CON-
TROL adjusts the full range of 50 to 575 amps. This setting provides a soft, constant current arc. If a more forceful arc is desired, then select the proper range from the slope controlled current ranges.
TIG WELDING
The Commander 400 can be used in a wide variety of
DC Tungsten Inert Gas (TIG) welding applications for
DC TIG welding up to 400 amps at a 20% duty cycle,
300 amps at a 60% duty cycle and 250 amps at a 80%
duty cycle. Refer to Table B.3 for recommended out-
put setting depending on the tungsten electrode size.
The Commander 400 can be used without a TIG module or Hi-Freq Unit for scratch start DC TIG welding.
Using a K799 Hi-Freq Unit or K930-1 TIG Module enables DC TIG welding without having to scratch start. The end of this section also details Commander
400 settings when using either of these units for DC
TIG welding. See “Commander 400 Settings When
Using the K799 Hi-Freq Unit” and “Commander 400
Settings When Using the K930-1 TIG Module.” See
the Accessories section for recommended equipment
for TIG welding.
COMMANDER 400
B-11 B-11
OPERATION
Table B.3 TYPICAL CURRENT RANGES
1
FOR TUNGSTEN ELECTRODES
2
Tungsten
Electrode
Diameter in. (mm)
0 .010
(.25)
0.020
(.50)
0.040 (1.0)
1/16
3/32
1/8
5/32
3/16
1/4
(1.6)
(2.4)
(3.2)
(4.0)
(4.8)
(6.4)
DCEN (-)
1%, 2%
Thoriated
Tungsten
2-15
5-20
15-80
70-150
150-250
250-400
400-500
500-750
750-1000
DCEP (+)
1%, 2%
Thoriated
Tungsten
3
3
3
10-20
15-30
25-40
40-55
55-80
80-125
Approximate Argon Gas Flow Rate
C.F.H. (l/min.)
Aluminum Stainless Steel
TIG TORCH
Nozzle
Size 4,5
3-8
5-10
5-10
(2-4)
(3-5)
(3-5)
3-8
5-10
5-10
(2-4)
(3-5)
(3-5)
5-10 (3-5) 9-13 (4-6)
13-17 (6-8)
15-23 (7-11)
11-15 (5-7)
11-15 (5-7)
#4, #5, #6
#5, #6
#6, #7, #8
21-25 (10-12)
23-27 (11-13)
28-32 (13-15)
13-17 (6-8)
18-22 (8-10)
23-27 (11-13)
#8, #10
1 When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.
2 Tungsten electrodes are classified as follows by the American Welding Society (AWS):
Pure EWP
1% Thoriated EWTh-1
2% Thoriated EWTh-2
Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated
Tungsten in AC and DC applications.
3 DCEP is not commonly used in these sizes.
4 TIG torch nozzle “sizes” are in multiples of 1/16ths of an inch:
# 4 = 1/4 in.
# 5 = 5/16 in.
(6 mm)
(8 mm)
# 6 = 3/8 in.
# 7 = 7/16 in.
# 8 = 1/2 in.
#10 = 5/8 in.
(10 mm)
(11 mm)
(12.5 mm)
(16 mm)
5 TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high temperatures and high duty cycles.
COMMANDER 400 SETTINGS WHEN USING THE
K799 HI-FREQ UNIT
1. Set the OUTPUT RANGE switch to the 50-575 setting
(Fabrication and General Purpose).
2. Set the IDLER switch to the “HIGH “ position.
3. Set the LOCAL/REMOTE switch to the “REMOTE” position.
4. Set the WELDING TERMINALS switch to the “WELD-
ING TERMINALS ALWAYS ON” position. This will close the solid state contactor and provide an always
“hot” electrode.
(Note: This is necessary because the K799 circuitry with respect to the #2 and #4 leads does not provide the proper signal to open and close the solid state contactor in the
Commander).
COMMANDER 400 SETTINGS WHEN USING THE
K930-1 TIG MODULE
1. Set the OUTPUT RANGE switch to the 50-575 Setting
(Fabrication and General Purpose).
2. Set the IDLER switch to the “AUTO “ position.
3. Set the LOCAL/REMOTE switch to the “REMOTE” position.
4. Set the WELDING TERMINALS switch to the “WELD-
ING TERMINALS REMOTELY CONTROLLED” position. This will keep the solid state contactor open and provide a “cold” electrode until the triggering device
(Amptrol or Arc Start switch) is pressed.
COMMANDER 400
B-12
WIRE FEED (CONSTANT VOLTAGE)
WELDING
Stick and Wire models only. Connect a wire feeder to
the Commander 400 (see the Accessories section)
and set the welder controls according to the instructions in “Controls and Settings” in this section of the manual.
The Stick and Wire model of the Commander 400, with its CV tap, permits it to be used with a broad range of flux cored wire (inner shield and Outer shield) electrodes and solid wires for MIG (GMAW).
For any electrodes, the procedures should be kept within the rating of this machine. For additional electrode information, see Lincoln publications N-675, GS-
100 and GS-210.
B-12
OPERATION
The following receptacles are provided:
• Two 15 amp-120VAC duplex FGCI receptacles
(5-15R)
• One 50 amp-120/240VAC receptacle (14-50R)
The 50 amp receptacle has a maximum permissible output of 44 amps. However, it can be split to power two separate, single-phase 120VAC branch circuits each capable of 44 amps output.
NOTE: The two 120VAC outlets of the 120/240VAC receptacle cannot be paralleled. They are on two different phases.
The auxiliary power receptacles should be used with only three-wire, grounded type plugs or approved double-insulated tools with two-wire plugs. The current rating of any plug used with the system must be at least equal to the current-carrying capacity of the associated receptacle. An optional power plug kit is available.
AUXILIARY POWER
WARNING
Be sure that any electrical equipment plugged into the generator AC power receptacles can withstand a ±10% voltage and a ±3% frequency variation.
SIMULTANEOUS WELDING AND AUXIL-
IARY POWER LOADS
The auxiliary power ratings above are with no welding load. Simultaneous welding and power loads are specified in Table B.4. The permissible currents shown assume that current is being drawn from either the 120
VAC or 240 VAC supply (not both at the same time).
The Commander 400 can produce 10,000 watts of 60
Hz, single-phase auxiliary power. (The rating in watts is equivalent to volt-amperes at unity power factor.)
The output voltage is within ±10% at all loads up to the rated capacity.
TABLE B.4 Commander 400 Simultaneous Welding and Power Loads
Welding
Output Range
Setting
Welding Output
50-575
400
270
230
180
120
90
500A/40V
400A/36V
270A/31V
230A/29V
180A/27V
120A/25V
90A/24V
Permissible
Power - Watts
(Unity Power
Factor)
Permissible Auxiliary
Current in Amperes
@120 V ±10% * @ 240 V ±10%
None
None
3000
6000
7500
9500
9500
0
0
28
56**
70**
88**
88**
0
0
14
28
35
44
44
* Each GFCI duplex receptacle is limited to 15 amps.
** Not to exceed 44 A per 120 VAC branch circuit when splitting the 240 VAC output.
COMMANDER 400
Section C-1
TABLE OF CONTENTS
- ACCESSORIES -
Accessories ...........................................................................................................................
Section C
Connection of the K488 SG Control Module and K487 Magnum Spool Gun ......................C-9
Section C-1
COMMANDER 400
C-2 C-2
ACCESSORIES
OPTIONS/ACCESSORIES
The following options/accessories are available for your Commander 400 from your local Lincoln
Distributor.
K802R Power Plug Kit - Provides a plug for each receptacle. The kit includes 4-120V plugs rated at 15
Amps each and 1-120V/240V Full-KVA plug rated at 50
Amps.
K857 28 ft. (8.5 m) or K857-1 100 ft. (30.4 m) Remote
Control - Portable control provides same dial range as the output control on the welder from a location up to the specified length from the welder. Has convenient plug for easy connection to the welder. The
Commander 400 is equipped with a 6 pin connector for connecting the remote control and a toggle switch for selecting “LOCAL” output control or “REMOTE” output control.
K704 Accessory Kit - Includes 35 feet (10 m) of electrode cable and 30 feet (9 m) of work cable, head shield, work clamp and electrode holder. Cable is rated at 500 amps, 60% duty cycle.
K953-1 Two Wheel Trailer - For road, in-plant and yard towing. Road towing with optional fender & light kit. (For highway use, consult applicable federal, state and local laws regarding possible additional requirements.)
K953-1 Trailer
K958-1 Ball Hitch
K958-2 Lunette Eye Hitch
K959-1 Fender & Light Kit
K965-1 Cable Storage Rack
K825-1 Ether Start Kit - Provides maximum cold weather starting assistance for frequent starting below
10 o F (-12.2
o C). Required Ether tank is not provided with kit.
K899-1 Spark Arrestor Kit - Easily mounts to standard muffler.
K949-1 Oil Drain Kit - Includes ball valve, hose and clamp.
STICK WELDING
K704 Accessory Kit which includes:
• Electrode holder and cable.
• Ground clamp and cable.
• Head shield.
TIG WELDING
Magnum TIG Torch
Magnum Parts Kit and Argon gas
K930-1 TIG Module (not required for scratch start DC TIG welding)
K936-3 Control Cable
K870 Foot Amptrol
Also available:
K963 Hand Amptrol
K814 Arc Start Switch
K937-22 Control Cable Extension
K937-45 Control Cable Extension
K844-1 Water Valve
HIGH FREQUENCY GENERATORS FOR TIG
APPLICATIONS
The K799 Hi-Freq Unit and the K930-1 TIG Module are suitable for use with the Commander 400. The
Commander is equipped with the required R.F. bypass circuitry for the connection of high frequency generating equipment. The high frequency bypass network supplied with the K799 Hi-Freq Unit does NOT need to be installed into the Commander 400.
The Commander 400 and any high frequency generating equipment must be properly grounded. See the
K799 Hi-Freq Unit and the K930-1 TIG Module operating manuals for complete instructions on installation, operation, and maintenance.
SEMIAUTOMATIC WELDING ACCESSORIES
LN-25 Wire Feeder - This portable wire feeder is capable of CC/CV wire feed welding.
LN-7 or LN-8 Wire Feeders - Semiautomatic, constant speed wire feeder. For CV operation only.
LN-23P Wire Feeder - This portable wire feeder is capable of CV operation. K350-1 adapter kit is required.
NOTE: Gas-shielded welding requires a Magnum Gun.
Gasless welding requires an Inner shield Gun.
Magnum Spool Gun (K487-25) - A lightweight, semiautomatic wire feeder for aluminum welding with argon gas. Has built-in remote wire speed control in the handle. Requires the K488 SG Control Module with appropriate control cable. Includes 25 feet (7.6 meters) of power cable.
COMMANDER 400
C-3
ACCESSORIES
CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS
WARNING
ELECTRIC SHOCK can kill.
• Do not operate with panels open.
• Disconnect NEGATIVE (-) BATTERY
LEAD before servicing.
• Do not touch electrically live parts.
MOVING PARTS can injure.
• Keep guards in place.
• Keep away from moving parts.
• Only qualified personnel should install, use or service this equipment.
C-3
3. Connect the K867 Universal Adapter to the K291 or
K404 input cable and the 14 pin amphenol of the
Commander 400 as indicated in Figure C.1. Make the proper connections for local or remote control according to Figure C.1.
4. Connect the K291 or K404 input cable to the LN-7.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
CONNECTION OF THE LN-7 TO THE
COMMANDER 400 USING K867
UNIVERSAL ADAPTER (SEE FIGURE C.1.)
1.
Shut the welder off.
2.
Connect the electrode cable from the LN-7 to the
“+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.1 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals.
6. Set the LOCAL/REMOTE switch to “REMOTE” if a
K775 remote control is used. Set the switch to
“LOCAL” if no remote control is used.
7. Set the VOLTMETER switch to “+” or “-” depending on the polarity chosen.
8. Set the RANGE switch to “WIRE WELDING CV.”
9. Set the WELDING TERMINALS switch to “WELD-
ING TERMINAL REMOTELY CONTROLLED.”
10. Adjust wire feed speed at the LN-7.
1 4 P I N
A M P H E N O L
C V+
TO WORK
FIGURE C.1
COMMANDER 400/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM
K867 UNIVERSAL
ADAPTER PLUG
ELECTRODE CABLE
TO WIRE FEED UNIT
SPARE
82
81
42
41
}
INSULATE UNUSED
LEADS INDIVIDUALLY
31
32
2
4
21
GND
75
76
77
SPLICE LEADS
AND INSULATE
31
32
2
4
21
GND
GREEN
75
76
77
COMMANDER 400
K291 OR K404
INPUT CABLE
LN-7
WIRE
FEEDER
K775 OPTIONAL
REMOTE CONTROL
C-4 C-4
ACCESSORIES
CONNECTION OF THE LN-7 TO THE
COMMANDER 400 USING K584 INPUT
CABLE ASSEMBLY (SEE FIGURE C.2.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
“+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.2 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals.
3. Connect the K584-XX Input Cable Assembly to the
LN-7.
4. Connect the K584-XX input cable assembly to the
14 pin amphenol on the Commander 400.
5. Place the IDLER switch in the “HIGH” position.
CAUTION
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE” if a
K857 remote control is used. Set the switch to
“LOCAL” if no remote control is used.
7. Set the VOLTMETER switch to “+” or “-” depending on the polarity chosen.
8. Set the RANGE switch to “WIRE WELDING CV.”
9. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
10. Adjust wire feed speed at the LN-7.
NOTE: For remote control, a K857 control is required.
Connect it to the 6 pin amphenol.
FIGURE C.2
COMMANDER 400/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM
6-PIN
14 PIN
AMPHENOL
CV-
+
TO WORK
TO LN-7 INPUT
CABLE PLUG
K595 CONTROL CABLE
OPTIONAL
K857 REMOTE
CONTROL
ELECTRODE CABLE
TO WIRE FEED UNIT
COMMANDER 400
C-5 C-5
ACCESSORIES
CONNECTION OF THE LN-8 TO THE
COMMANDER 400 USING K867
UNIVERSAL ADAPTER (SEE FIGURE C.3.)
1.
Shut the welder off.
2.
Connect the electrode cable from the LN-8 to the
“+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.3 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals.
3. Connect the K867 Universal Adapter to the K196 input cable and the 14 pin amphenol of the
Commander 400 as indicated in Figure C.3. Make the proper connections for local or remote control according to Figure C.3.
4. Connect the K196 input cable to the LN-8.
5. Place the IDLER switch in the “HIGH” position.
CAUTION
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE.”
7. Set the VOLTMETER switch to “+” or “-” depending on the polarity chosen.
8. Set the RANGE switch to “WIRE WELDING CV.”
9. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
10. Adjust wire feed speed and voltage at the LN-8.
FIGURE C.3
COMMANDER 400/LN-8 WITH K867 ADAPTER CONNECTION DIAGRAM
14 PIN
AMPHENOL
CV+
TO WORK
K867 UNIVERSAL
ADAPTER PLUG
ELECTRODE CABLE
TO WIRE FEED UNIT
31
32
2
4
21
GND
75
76
77
SPARE
82
81
42
41
}
INSULATE UNUSED
LEADS INDIVIDUALLY
31
32
2
4
21
GND
A
B
C
SPLICE LEADS
AND INSULATE
K196
INPUT CABLE
LN-8
WIRE
FEEDER
COMMANDER 400
C-6
ACCESSORIES
CONNECTION OF THE LN-8 TO THE
COMMANDER 400 USING K595 INPUT
CABLE ASSEMBLY (SEE FIGURE C.4.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-8 to the
“+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.4 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals.
3. Connect the K595-XX Input Cable Assembly to the
LN-8.
4. Connect the K595-XX to the 14 pin amphenol on the Commander 400.
5. Place the IDLER switch in the “HIGH” position.
C-6
CAUTION
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE.”
7. Set the VOLTMETER switch to “+” or “-” depending on the polarity chosen.
8. Set the RANGE switch to “WIRE WELDING CV.”
9. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
10. Adjust wire feed speed and voltage at the LN-8.
FIGURE C.4
COMMANDER 400/LN-8 WITH K595 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM
TO LN-8 INPUT
CABLE PLUG
K595 CONTROL CABLE
14 PIN
AMPHENOL
CV-
+
TO WORK
ELECTRODE CABLE
TO WIRE FEED UNIT
COMMANDER 400
C-7 C-7
ACCESSORIES
CONNECTION OF THE LN-23P TO THE
COMMANDER 400 USING K350-1
ADAPTER (SEE FIGURE C.5.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-23P to the “CV- Wire” terminal of the welder. Connect the work cable to the “+” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.5 shows the electrode connected for negative polarity.
3. Connect the K350-1 adapter to the 6 pin amphenol on the LN-23P and the 14 pin amphenol of the
Commander 400 as indicated in Figure C.5.
4. Place the IDLER switch in the “AUTO” position.
CAUTION
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
5. Set the VOLTMETER switch to negative.
6. Set the RANGE switch to “WIRE WELDING CV.”
7. Set the WELDING TERMINALS switch to ‘WELD-
ING TERMINALS REMOTELY CONTROLLED.”
8. Set the LOCAL/REMOTE switch according to whether you are controlling the welder at the machine or remotely.
9. Adjust wire feed speed and voltage at the LN-23P.
FIGURE C.5
COMMANDER 400/LN-23P CONNECTION DIAGRAM
14 PIN
AMPHENOL
ADAPTER
KIT
K350-1
6 PIN
AMPHENOL
LN-23P
WIRE FEEDER
+
TO WORK
CV-
ELECTRODE
ELECTRODE CABLE
TO WORK
COMMANDER 400
C-8 C-8
ACCESSORIES
CONNECTION OF THE LN-25 TO THE
COMMANDER 400 “ACROSS THE ARC”
(SEE FIGURE C.6.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-25 to the
“-” terminal of the welder. Connect the work cable to the “CV-” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.6 shows the electrode connected for negative polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals. Reverse the LN-25 polarity switch.
3. Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead. This is only a control lead — it carries no welding current.
4. Place the IDLER switch in the “AUTO” position.
CAUTION
If you are using an LN-25 without an internal contactor, the electrode will be “HOT” when the Commander
400 is started.
5. Set the RANGE switch to “WIRE WELDING CV.”
6. Set the WELDING TERMINALS switch to ‘WELD-
ING TERMINALS ALWAYS ON.”
7. Set the VOLT METER switch to “+” or “-” depending on the polarity chosen.
8. Adjust wire feed speed at the LN-25.
9. Set the LOCAL/REMOTE switch to “REMOTE” if a
K444-1 remote control is used.
CAUTION
Electrode is always “HOT.”
AMPHENOL
14 PIN
FIGURE C.6
COMMANDER 400/LN-25 ACROSS THE ARC CONNECTION DIAGRAM
+ CV-
6 PIN
AMPHENOL
TO WORK
OPTIONAL K444-1
REMOTE CONTROL
LN-25
WIRE FEEDER
WORK CLIP LEAD
TO WORK
ELECTRODE CABLE
COMMANDER 400
C-9 C-9
ACCESSORIES
CONNECTION OF THE K488 SG CONTROL
MODULE AND K487 MAGNUM SPOOL GUN
TO THE COMMANDER 400 (SEE FIGURE
C.7.)
1. Shut the welder off.
2. Connect the electrode cable from the SG Control
Module to the “+” terminal of the welder. Connect the work cable to the “CV- Wire” terminal of the welder.
NOTE: Welding cable must be sized for current and duty cycle of application.
NOTE: Figure C.7 shows the electrode connected for positive polarity. To change polarity, shut the welder off and reverse the electrode and work cables at the
Commander 400 output terminals.
3. Connect the K691-10 input cable as shown in
Figure C.7.
4. Set the slide switch on the SG Control Module to the “Lincoln” position.
CAUTION
Be sure this switch is set to the “Lincoln” (contact closure) position before attempting to operate the SG
Control Module. Incorrect switch position could result in damage to the SG Control Module and/or the
Commander 400.
5. Place the IDLER switch on the Commander 400 in the “HIGH” position.
CAUTION
Any increase of the high idle engine RPM by changing the governor setting or overriding the throttle linkage will cause an increase in the AC auxiliary voltage. If this voltage goes over 140 volts, wire feeder control circuits may be damaged. The engine governor setting is preset at the factory — do not adjust above
RPM specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE” if a
K857 remote control is used. Set the switch to
“LOCAL” if no remote control is used.
7. Set the VOLTMETER switch to “+” or “-” depending on the polarity chosen.
8. Set the RANGE switch to “WIRE WELDING CV.”
9. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
10. Adjust wire feed speed at the SG Control Module.
NOTE: For remote control, a K857 remote control is required. Connect it to the 6 pin amphenol.
FIGURE C.7
COMMANDER 400/K691/K488/K487 SPOOL GUN CONNECTION DIAGRAM
11 5 V R E C E P TA C L E
K488 SG
CONTROL MODULE
K487-25
SPOOL GUN
1 4 P I N W I R E F E E D E R
R E C E P TA C L E
TO W O R K
E L E C T R O D E
6 PIN REMOTE
RECEPTACLE
TO WORK
ELECTRODE CABLE
TO CONTROL MODULE
K691-10
INPUT CABLE
COMMANDER 400
C-10
NOTES
C-10
COMMANDER 400
Section D-1
TABLE OF CONTENTS
-MAINTENANCE-
Maintenance .........................................................................................................................
Section D
Section D-1
COMMANDER 400
D-2 D-2
MAINTENANCE
SAFETY PRECAUTIONS
WARNING
• Have qualified personnel do all maintenance and troubleshooting work.
• Turn the engine off before working inside the machine.
• Remove covers or guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete.
• If covers or guards are missing from the machine, get replacements from a Lincoln Distributor.
ROUTINE AND PERIODIC
MAINTENANCE
ENGINE MAINTENANCE
CAUTION
To prevent the engine from accidentally starting, disconnect the negative battery cable before servicing the engine.
Read the Safety Precautions in the front of this manual and in the instruction manual for the diesel engine used with your machine before working on the
Commander 400.
Keep all equipment safety guards, covers, and devices in position and in good repair. Keep your hands, hair, clothing, and tools away from the fans, and all other moving parts when starting, operating, or repairing this machine.
See Table D.1 for a summary of maintenance intervals
for the items listed below. Follow either the hourly or the calendar intervals, whichever come first. More frequent service may be required, depending on your specific application and operating conditions.
OIL: Check the oil level after every 8 hours of operation or daily. BE SURE TO MAINTAIN THE OIL
LEVEL.
Change the oil the first time between 25 and 50 hours of operation. Then, under normal operating conditions, change the oil as specified in Table D.1. If the engine is operated under heavy load or in high ambient temperatures, change the oil more frequently.
CHANGE THE OIL: Change the oil, while the engine is still warm, as follows:
1 . Drain the oil from the drain plug located on the
engine bottom, as shown in Figure D.1. Examine
the washer and replace it if it appears damaged.
2.
Replace the plug and washer and tighten firmly.
3.
Remove the oil fill cap and add oil until the level reaches the “MAX” mark on the dipstick. See
Figure D.1. Use high quality oil viscosity grade
10W40. Consult the engine manual for oil specifications for various ambient temperatures. Always check the level with the dipstick before adding more oil.
4. Reinstall the oil fill cap and the dipstick.
COMMANDER 400
D-3 D-3
MAINTENANCE
FIGURE D.1 – OIL DRAIN AND REFILL
MAX
MIN
OIL FILL CAP
OIL FILTER DIPSTICK DRAIN PLUG
CHANGE THE OIL FILTER: Change the oil filter the first time between 25 and 50 hours of operation. Then, under normal operating conditions, change the oil filter after every 250 hours of operation. If the engine is operated under heavy load or in high ambient temperatures, change the oil filter more frequently. See Table
D.1 for recommended maintenance intervals. See
Table D.2 for replacement oil filters.
Change the oil filter as follows:
1.
Remove the oil drain plug. Drain the oil from the engine and allow the oil filter to drain. See Figure
D.1.
2.
Remove the old filter (spin it off) and discard it (2).
Wipe off the filter mounting surface and adapter.
See Figure D.1.
3.
Fill the new filter with fresh engine oil. Apply a thin coat of new oil to the rubber gasket on the new oil filter.
4.
Spin the new filter onto the mounting adapter finger tight until the gasket is evenly seated. Then turn it down another 1/2 turn. Do not over tighten the new filter.
5.
Refill the engine with the proper amount and type
of oil as described in the Change the Oil section,
above. Start the engine and check for leaks around the filter element. Correct any leaks (usually by retightening the filter, but only enough to stop leaks) before placing the Commander 400 back in service.
6.
If there are no leaks, stop the engine and recheck the oil level. If necessary, add oil to bring the level up to the “MAX” mark, but do not overfill. See
Figure D.1.
FUEL: At the end of each day's use, refill the fuel tank to minimize moisture condensation and dirt contamination in the fuel line. Do not overfill; leave room for the fuel to expand.
Refer to your engine operation manual for recommended grade of fuel.
COMMANDER 400
D-4 D-4
MAINTENANCE
FUEL FILTERS:
WARNING
When working on the fuel system:
• Keep unshielded lights away, do not smoke !
• Do not spill fuel !
The Commander 400 is equipped with a Fuel Pre-
Filter/Water Separator Assembly located before the lift pump and a Secondary Fuel Filter located after the lift pump and before the fuel injectors. The Fuel Pre-
Filter/Water Separator is mounted to the engine block just below the lift pump (Figure D.2). The Secondary
Fuel Filter is mounted directly to the engine just above
Fuel Pre-Filter/Water Separator Assembly: The prefilter is a 150 micron screen designed to protect against gross fuel contamination of the water separator element and the Secondary Fuel Filter. If the pre-filter becomes plugged, it may be removed, inspected, cleaned and reinstalled. In general this only needs to be done with each water separator element change
(about every 1,000 hrs). However, if at any time excessive fuel contamination is suspected or a sudden falloff in engine performance is detected the pre-filter screen should be inspected and cleaned. See Figure
D.2 and follow this procedure:
1. Close the fuel shutoff valve located on the side of the Fuel Pre-Filter/Water Separator Assembly. The lever should be perpendicular to the hose
2. Unscrew the cap ring located on the top of the filter header and remove the plastic center cap and Oring.
3. Remove the large white volume plug located directly under the center cap in the upper cavity of the filter header. Use a small screwdriver (or similar device) to lift the plug part way out of the cavity to assist with its removal.
NOTE: Be careful not to damage the pre-filter screen with the tool used to remove the plug.
4. Using a pair of pliers, gently tug on the pull tabs of the pre-filter screen in an alternating pattern to gradually remove the pre-filter screen.
5. Brush off any debris and rinse in diesel fuel.
6. Re-install the pre-filter screen into the upper cavity of the filter header making sure the four pull tabs are pointing up. Putting your fingers on the pull tabs, push down evenly until the lower body of the pre-filter screen contacts the floor of the upper cavity.
7. Re-insert the large white volume plug into the upper cavity.
8. Place the O-ring onto the angled seal surface of the filter header and re-install the plastic cap. Make sure its flange rests on the O-ring.
9. Screw on the cap ring and tighten hand tight.
10. Remember to open the fuel shutoff valve (Lever in line with the hose) before starting the engine.
Water Separator Element: The water separator element is a two-stage filter with a special filtration/water separating media. An expanded water reservoir provides maximum protection against water in the fuel.
The recommended change interval for the water separator element is 1,000 hours. See Figure D.2 and follow this procedure.
1. Close the fuel shutoff valve located on the side of the Fuel Pre-Filter/Water Separator Assembly. The lever should be perpendicular to the hose.
2. Rotate the quick change ring (located just below filter header) clockwise approximately 1/2 turn and slide it down and off the element.
3. Grasp the element and pull down with a slight rocking motion to remove the element from the grommet post on the bottom of the filter header.
FIGURE D.2 – FUEL PRE-FILTER/WATER
SEPARATOR ASSEMBLY
FUEL
SHUTOFF
VALVE
FILTER
HEADER
QUICK
CHANGE
RING
CAP
RING
COMMANDER 400
D-5 D-5
MAINTENANCE
4. Slide the new element onto the grommet post on the bottom of the filter header until the element no longer easily moves up into the filter header. Now rotate the element (it may take almost 1 full turn) with a slight upward pressure until the element begins to further engage the header. With the proper orientation now established, apply additional pressure to seat the element in the filter header. You should feel the element “pop” into place when properly seated.
NOTE: The element will only go on one way. Never use excessive force when mounting the element to the header.
5. Slide the quick change ring up over the element and rotate counter clockwise until an audible click or pop is heard. If you do not hear the click, you have not rotated the ring far enough and the element is not in the locked position. Another indication that the ring is in the locked position is that one set (it doesn’t matter which one) of arrows located on the outside of the ring should be located directly under the air vent valve.
6. Open the fuel shutoff valve (lever in line with the hose).
7. Open the air vent valve on the front of the filter header until fuel emerges free of air bubbles. Then close the air vent valve.
Secondary Fuel Filter: The Secondary Fuel Filter is a spin-on cartridge type mounted directly to the engine.
Consult your engine operation manual for complete information on service intervals and element changing procedures.
FIGURE D.3 – SECONDARY FUEL FILTER
SECONDARY
FUEL FILTER
OIL
FILTER
COMMANDER 400
D-6 D-6
MAINTENANCE
BLEEDING THE FUEL SYSTEM: In the event the engine is operated until it runs out of fuel, you will need to bleed the fuel system in order to start the engine.
Refer to the engine operation manual.
AIR FILTER:
CAUTION
Excessive air filter restriction will result in reduced engine life.
The air filter element is a dry cartridge type. It can be cleaned and reused. However, damaged elements should not be reused. Stop engine after 100 hours of running time and clean filter element. Replace the filter if necessary. Service the air cleaner regularly according to your engine operation manual.
1. Locate the air filter canister located behind the engine door on the top of the engine.
2. Remove the air filter element.
3. Remove loose dirt from the element with compressed air or a water hose directed from inside out.
Compressed Air: 100 psi maximum with nozzles at least one inch away from the element.
Water Hose: 40 psi maximum without nozzle.
4. Soak the element in a mild detergent solution for 15 minutes. Do not soak more than 24 hours. Swish the element around in the solution to help remove dirt.
5. Rinse elements from inside out with a gentle stream of water (less than 40 psi) to remove all suds and dirt.
6.Dry the element before reuse with warm air at less than 160 o F (71 o C). Do not use a light bulb to dry the element.
7. Inspect for holes and tears by looking through the element toward a bright light. Check for damaged gaskets or dented metal parts. Do not reuse damaged elements. Protect the element from dust and damage during drying and storage.
8. Reinstall the air filter element.
After six cleanings, replace the air filter. A cleaned filter will have approximately 70% of the life of a new filter element. A restricted filter element may not appear excessively dirty.
COMMANDER 400
D-7 D-7
MAINTENANCE
COOLING SYSTEM: The cooling system of the Deutz engine needs to be checked and cleaned periodically.
Consult the engine Operation Manual for the proper frequency and procedure.
COOLING BLOWER BELT: The following procedure should be followed to replace the cooling blower belt:
1. Allow the machine to cool.
2. Unfasten and slide the battery holder out from the welder.
3. Disconnect the negative battery cable.
4. Remove the engine end panel for access to the engine.
5. See Figure D.4. Loosen the alternator mounting bolts (1, 2, 3) and rotate the alternator toward the engine.
6. Remove the old cooling blower belt and install a new one.
7. Push outward on the alternator (4) and adjust the cold belt tension to 63-73 lbs. (10-15 mm maximum deflection) midway between any two pulleys.
Tighten bolts (1), (2), (3).
8. Reinstall the engine end panel. Reattach the negative battery cable. Slide in and refasten the battery holder.
9. Check the cooling blower belt tension after 100 hours of operation.
FIGURE D.4 – COOLING BLOWER BELT REPLACEMENT AND ADJUSTING
1
2
4
3
COMMANDER 400
D-8
MAINTENANCE
TABLE D.1
DEUTZ ENGINE MAINTENANCE SCHEDULE
MAINTENANCE REQUIRED FREQUENCY
Daily or Before
Starting Engine
• Fill fuel tank.
• Check oil level.
• Check air cleaner for dirty, loose, or damaged parts. Replace if necessary.
• Check air intake and cooling areas, clean as necessary.
1 First 50 Hours • Change engine oil.
and Every 250 • Change oil filter.
Hours Thereafter • Change fuel filter.
• Check fan belt.
Every 50 Hours • Check fuel lines and clamps.
Every 100 Hours • Check battery electrolyte level and connections.
• Clean air filter.
Refer to your Deutz engine operation manual for periodic maintenance at 100 hours and beyond.
1 125 Hours for severe conditions.
D-8
COMMANDER 400
D-9
MAINTENANCE
ITEM
Air Cleaner Element
Cooling Blower Belt
Oil Filter Element
Fuel Filter Element
Water Separator Element
Fuel Pre-Filter Screen
Table D.2
ENGINE MAINTENANCE PARTS
MANUFACTURER
Donaldson
AC
Lincoln
Gates
Deutz
Purolator
Napa
Fram
Deutz
Purolator
Napa
Fram
Lincoln
Stanadyne
Lincoln
Stanadyne
Battery
PART NUMBER
P181052
A302C
T13536-3
7585
1174418
PER2168
1820
PH3776
1174423
PC42
3358
P4102
M16890-C
31572
M16890-B
29575
BCI
Group
34
D-9
COMMANDER 400
D-10
BATTERY MAINTENANCE
WARNING
GASES FROM BATTERY can explode.
• Keep sparks, flame, and cigarettes away from battery.
D-10
MAINTENANCE
CHECKING SPECIFIC GRAVITY: Check each battery cell with a hydrometer. A fully charged battery will have a specific gravity of 1.260. Charge the battery if the reading is below 1.215.
NOTE: Correct the specific gravity reading by adding four gravity points (0.004) for every five degrees the electrolyte temperature is above 80 degrees F (27 degrees (C). Subtract four gravity points (.004) for every five degrees the electrolyte temperature is below
80 degrees F (27 degrees C).
BATTERY ACID can burn eyes and skin.
• Wear gloves and eye protection and be careful when working near a battery.
Follow the instructions printed on the battery.
To prevent EXPLOSION when:
• INSTALLING A NEW BATTERY - Disconnect the negative cable from the old battery first and connect to the new battery last.
• THE CORRECT POLARITY IS NEGATIVE GROUND -
Damage to the engine alternator and the printed circuit board can result from incorrect connection.
• CONNECTING A BATTERY CHARGER -
Remove the battery from the welder by disconnecting the negative cable first, then the positive cable and battery clamp. When reinstalling, connect the negative cable last. Keep the area well ventilated.
• USING A BOOSTER - Connect the positive lead to the battery first, then connect the negative lead to the engine foot.
• To prevent BATTERY BUCKLING, tighten the nuts on the battery clamp until snug.
CHECKING ELECTROLYTE LEVEL: If battery cells are low, fill them to the neck of the filler hole with distilled water and recharge. If one cell is low, check for leaks.
CHARGING THE BATTERY: The Commander 400 is equipped with a wet charged battery. The charging current is automatically regulated when the battery is low (after starting the engine) to a trickle current when the battery is fully charged.
When you charge, jump, replace, or otherwise connect battery cables to the battery, be sure the polarity is correct. Improper polarity can damage the charging circuit. The Commander 400 charging system is NEG-
ATIVE GROUND. The positive (+) battery terminal has a red terminal cover.
If you need to charge the battery with an external charger, disconnect the negative cable first, then the positive cable before you attach the charger leads.
After the battery is charged, reconnect the positive battery cable first and the negative cable last. Failure to do so can result in damage to the internal charger components.
Follow the instructions of the battery charger manufacturer for proper charger settings and charging time.
CLEANING THE BATTERY: Keep the battery clean by wiping it with a damp cloth when dirty. If the terminals appear corroded, disconnect the battery cables and wash the terminals with an ammonia solution or a solution of 1/4 pound (0.113 kg) of baking soda and 1 quart (0.946 l) of water. Be sure the battery vent plugs
(if equipped) are tight so that none of the solution enters the cells.
After cleaning, flush the outside of the battery, the battery compartment, and surrounding areas with clear water. Coat the battery terminals lightly with petroleum jelly or a non-conductive grease to retard corrosion.
Keep the battery clean and dry. Moisture accumulation on the battery can lead to more rapid discharge and early battery failure.
COMMANDER 400
D-11 D-11
MAINTENANCE
WELDER/GENERATOR
MAINTENANCE
STORAGE: Store the Commander 400 in clean, dry, protected areas.
CLEANING: Blow out the generator and controls periodically with low pressure air. Do this at least once a week in particularly dirty areas.
NAME PLATES: Whenever routine maintenance is performed on this machine - or at least yearly - inspect all name plates and labels for legibility. Replace those which are no longer clear. Refer to the parts list for the replacement item number.
BEARINGS: The Commander 400 is equipped with double-shielded ball bearings having sufficient grease to last indefinitely under normal service. Where the welder is used constantly or in excessively dirty locations, it may be necessary to add one half ounce of grease per year. A pad of grease one inch wide, one inch long, and one inch high weighs approximately one half ounce. Over-greasing is far worse than insufficient greasing.
When greasing the bearings, keep all dirt out of the area. Wipe the fittings completely clean and use clean equipment. More bearing failures are caused by dirt introduced during greasing than from insufficient grease.
RECEPTACLES: Keep the electrical receptacles in good condition. Remove any dirt, oil, or other debris from their surfaces and holes.
CABLE CONNECTIONS: Check the welding cable connections at the weld output terminals often. Be sure that the connections are always tight.
COMMANDER 400
D-12
1. CASE DOOR ASSEMBLY
2. ENGINE
3. SHUTDOWN SOLENOID
4. IDLER SOLENOID
5. REAR PANEL ASSEMBLY
6. BASE
7. FRONT PANEL ASSEMBLY
8. CONTROL PANEL
9. SCR/DIODE RECTIFIER
BRIDGE ASSEMBLY
10. FUEL TANK
11. CAPACITOR BANK
12. ROTOR/STATOR
13. CASE TOP AND SIDES
MAINTENANCE
FIGURE D.5 - MAJOR COMPONENT LOCATIONS
1
13
11
12
10
7
5
9
2
3
5
4
D-12
6
8
7
COMMANDER 400
Section E-1
TABLE OF CONTENTS
-THEORY OF OPERATION SECTION-
Theory of Operation .............................................................................................................
Section E
Section E-1
BATTERY
STARTER
ALTERNATOR
ENGINE
MECHANICAL
ROTATION
SHUTDOWN
SOLENOID
WELD
ROTOR
EXCITER
WINDINGS
WINDING
S
IDLER
SOLENOID
EXCITER
CAPACITORS
115/230VAC
RECEPTACLE
115VAC
14 PIN
AMPHENOL
6 PIN
AMPHENOL
BY-PASS
PC
BOARD
ENGINE
SENSORS
EXCITER VOLTAGE
FEEDBACK
BOARD
SCR/DIODE
OUTPUT
BRIDGE
CV
CAPACITO
RS
SCR GATE SIGNALS
OUTPUT
CHOKE
SHUNT
FEEDBACK
D
B
A
C
K
F
E
E
NEGATIVE
TERMINAL
CV
TERMINAL
POSITIVE
TERMINAL
42VAC
REMOTE
SWITCH
FINE
OUTPUT
CONTROL
ENGINE
PROTECTION
BOARD
CV
BOARD
MAIN
CONTROL
BOARD
METER
CURRENT/ MODE
SELECTOR
SWITCH
12VDC
FIGURE E.1 – COMMANDER 400 BLOCK LOGIC DIAGRAM
COMMANDER 400
E-2
BATTERY
STARTER
ALTERNATOR
ENGINE MECHANICAL
ROTATION
SHUTDOWN
SOLENOID
WELD
ROTOR
EXCITER
WINDINGS
WINDING
S
IDLER
SOLENOID
EXCITER
CAPACITORS
115/230VAC
RECEPTACLE
115VAC
14 PIN
AMPHENOL
6 PIN
AMPHENOL
BY-PASS
PC
BOARD
ENGINE
SENSORS
EXCITER VOLTAGE
FEEDBACK
BOARD
SCR GATE SIGNALS
42VAC
REMOTE
SWITCH
FINE
OUTPUT
CONTROL
ENGINE
PROTECTION
BOARD
CV
BOARD
MAIN
CONTROL
BOARD
E-2
THEORY OF OPERATION
FIGURE E.2 – BATTERY, STARTER, ENGINE, ROTOR AND STATOR
SCR/DIODE
OUTPUT
BRIDGE
CV
CAPACITO
RS
OUTPUT
CHOKE
SHUNT
FEEDBACK
B
A
C
K
F
E
E
D
NEGATIVE
TERMINAL
CV
TERMINAL
POSITIVE
TERMINAL
METER
CURRENT/ MODE
SELECTOR
SWITCH
12VDC
GENERAL DESCRIPTION
The Commander 400 is a diesel engine driven welding power source. The machine uses a brushless asynchronous alternating current generator for DC stick electrode welding and for 120/240 VAC auxiliary standby power. As a generator it can supply up to 10,000 watts of 120/240 volt AC power. As a welder it provides up to 400 amps of DC constant current output in six slope-controlled ranges. In addition a seventh general purpose welding range provides up to 575 amps of constant current welding output.
The stick and wire model has a CV terminal for constant voltage wire welding.
BATTERY, STARTER, ENGINE,
ROTOR AND STATOR
The 12VDC battery powers the engine starter motor and supplies power to the main control board for the engine protection circuitry. The engine's alternator supplies "charging" current for the battery circuit. The battery circuit also provides power through the main control board for the idler solenoid, which is mechanically coupled to the engine's throttle linkage.
The diesel engine is coupled to a brushless asynchronous three-phase alternating current induction genera-
tor. See Induction Generators.
The excitation or
"flashing" voltage is developed in the exciter windings and capacitor configuration. The rotor, which is manufactured by casting aluminum through steel lamination, is mechanically coupled to the engine. Through excitation of this rotating magnet, voltages are produced in the stationary windings of the stator. There are three separate and isolated sets of windings incorporated in the stator lamination. Each set has a different number of turns producing different magnitudes of AC output voltages. These three windings are the three-phase weld winding, the three-phase exciter winding; which is tapped for single phase auxiliary standby power; and the 42VAC single-phase winding, which supplies power to the main control board.
The engine protection circuit shuts the engine off in the event of low oil pressure, engine over temperature, malfunction in the engine's alternator system, or a low fuel condition.
NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.
COMMANDER 400
E-3
THEORY OF OPERATION
FIGURE E.3 – EXCITER FEEDBACK, CONTROL BOARD, LOCAL AND REMOTE CONTROL
E-3
BATTERY
STARTER
ALTERNATOR
ENGINE
MECHANICAL
ROTATION
SHUTDOWN
SOLENOID
WELD
ROTOR
EXCITER
WINDINGS
WINDINGS
IDLER
SOLENOID
EXCITER
CAPACITORS
115/230VAC
RECEPTACLE
115VAC
14 PIN
AMPHENOL
6 PIN
AMPHENOL
BY-PASS
PC
BOARD
ENGINE
SENSORS
EXCITER VOLTAGE
FEEDBACK
BOARD
SCR/DIODE
OUTPUT
BRIDGE
CV
ITORS
CAPAC
SCR GATE SIGNALS
OUTPUT
CHOKE
SHUNT
FEEDBACK
F
E
E
D
B
A
C
K
NEGATIVE
TERMINAL
CV
TERMINAL
POSITIVE
TERMINAL
42VAC
REMOTE
SWITCH
FINE
OUTPUT
CONTROL
ENGINE
PROTECTION
BOARD
CV
BOARD
MAIN
CONTROL
BOARD
METER
CURRENT/ MODE
SELECTOR
SWITCH
12VDC
EXCITER FEEDBACK, CONTROL
BOARD, LOCAL AND REMOTE
CONTROL
The exciter voltage is monitored and fed back through the exciter voltage feedback board to the control board.
In the event the exciter voltage increases or decreases to an unacceptable level, the engine protection circuit shuts off the engine.
The control board compares the commands of the current/mode selector and the fine output control (or remote control) with the output voltage and current feedback and sends the appropriate SCR gate firing signals to the SCR/Diode bridge.
The Commander 400 is controlled by a high quality microcontroller, which is the main circuit element of the control board.
The control board also supplies operating voltages and control signals to the CV board, the meter board, and the engine protection board.
The remote control and contactor signals are fed to the control board through the amphenols and the by-pass board.
NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.
COMMANDER 400
E-4
THEORY OF OPERATION
FIGURE E.4 – WELD WINDING, OUTPUT BRIDGE, OUTPUT CHOKE AND CV CAPACITORS
E-4
BATTERY
STARTER
ALTERNATOR
ENGINE MECHANICAL
ROTATION
SHUTDOWN
SOLENOID
WELD
ROTOR
EXCITER
WINDINGS
WINDINGS
IDLER
SOLENOID
EXCITER
CAPACITORS
115/230VAC
RECEPTACLE
115VAC
14 PIN
AMPHENOL
6 PIN
AMPHENOL
BY-PASS
PC
BOARD
ENGINE
SENSORS
EXCITER VOLTAGE
FEEDBACK
BOARD
SCR/DIODE
OUTPUT
BRIDGE
CV
ITORS
CAPAC
SCR GATE SIGNALS
OUTPUT
CHOKE
SHUNT
FEEDBACK
B
A
C
K
F
E
E
D
NEGATIVE
TERMINAL
CV
TERMINAL
POSITIVE
TERMINAL
42VAC
REMOTE
SWITCH
FINE
OUTPUT
CONTROL
ENGINE
PROTECTION
BOARD
CV
BOARD
MAIN
CONTROL
BOARD
METER
CURRENT/ MODE
SELECTOR
SWITCH
12VDC
WELD WINDING, OUTPUT BRIDGE,
OUTPUT CHOKE AND CV CAPACI-
TORS
The three-phase AC output that is created in the stator weld winding is connected to the SCR/Diode output
bridge where it is rectified and controlled. See SCR
A choke is connected between the negative side of the bridge and the negative output terminal. This large inductor stores energy and provides filtering for the welding output of the Commander 400.
In the constant voltage (CV) mode, the CV capacitors are brought into the welding circuit via an SCR that is activated by the CV board. These capacitors add voltage filtering and help maintain a constant arc voltage at the output terminals.
1
The shunt, which is in series with the positive output terminal, provides current feedback to the control board.
1 CV Board and CV Capacitors are present on stick and wire model only.
NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.
COMMANDER 400
E-5
THEORY OF OPERATION
FIGURE E.6 – SCR OPERATION
E-5
SCR OPERATION
A silicon controlled rectifier (SCR) is a three terminal device used to control rather large currents to a load.
An SCR acts very much like a switch. When a gate signal is applied to the SCR, it is turned ON and there is current flow from anode to cathode. In the ON state the
SCR acts like a closed switch. When the SCR is turned
OFF, there is no current flow from anode to cathode and the device acts like an open switch. As the name suggests, the SCR is a rectifier, so it passes current only during positive half cycles of the AC supply. The positive half cycle is the portion of the sine wave in which the anode of the SCR is more positive than the cathode.
When an AC supply voltage is applied to the SCR, the device spends a certain portion of the AC cycle time in the ON state and the remainder of the time in the OFF state. The amount of time spent in the ON state is controlled by the Gate.
An SCR is fired by a short burst of current into the gate.
This gate pulse must be more positive than the cathode voltage. Since there is a standard PN junction between gate and cathode, the voltage between these terminals must be slightly greater than 0.6V. Once the SCR has fired it is not necessary to continue the flow of gate current. As long as current continues to flow from anode to cathode, the SCR will remain on. When the anode to cathode current drops below a minimum value, called holding current, the SCR will shut off. This normally occurs as the AC supply voltage passes through zero into the negative portion of the sine wave. If the
SCR is turned on early in the positive half cycle, the conduction time is longer, resulting in greater SCR output. If the gate firing occurs later in the cycle, the conduction time is less, resulting in lower SCR output.
Commander 400
E-6 E-6
THEORY OF OPERATION
INDUCTION GENERATORS
The Commander 400 utilizes a brushless
Asynchronous Induction Generator to convert mechanical energy into electrical energy. The following is a brief description of an induction generator.
The induction generator is an induction motor driven above the synchronous speed. The rotor conductors pass through the magnetic field of the stator in a direction that converts mechanical energy into electrical energy. Typical alternators (synchronous generators) are not self-excited. An induction generator must be connected in parallel with an electrical system that provides out-of-phase current or reactive power for excitation. The capacitors used in the Commander 400 provide the same reactive power that an induction motor would use for power factor correction. In fact, the amount of reactive power used by an induction generator is equal to that used by an induction motor of the same size.
To summarize, the stand-alone induction generator used in the Commander 400 converts mechanical energy into electrical energy. The electrical energy supplied by the capacitors is transferred magnetically to the rotor. Mechanical energy is supplied to the magnetized rotor in the form of torque and rotational speed.
The majority of this energy is magnetically delivered to the stator weld coils.
COMMANDER 400
Section F-1
TABLE OF CONTENTS
TROUBLESHOOTING & REPAIR SECTION
Troubleshooting & Repair Section ................................................................................Section F
Initialization Sequence and Commander 400 Error Code Explanations .............................F-16
Case Front Knobs - Removal and Replacement Procedure.........................................F-32
Normal Open Circuit Voltage Waveform (115 VAC Supply)..........................................F-72
Control PC Board Removal, Replacement, and Calibration .........................................F-81
Section F-1
COMMANDER 400
F-2
TROUBLESHOOTING & REPAIR
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and repair should be performed by only Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM” (SYMP-
TOMS). This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting. Symptoms are grouped into four main categories: Output Problems,
Engine Problems Function Problems, and
Welding Problems.
Step 3. PERFORM COMPONENT TESTS. The last column, labeled “Recommended Course of
Action” lists the most likely components that may have failed in your machine. It also specifies the appropriate test procedure to verify that the subject component is either good or bad. If there are a number of possible components, check the components in the order listed to eliminate one possibility at a time until you locate the cause of your problem.
Step 2. PERFORM EXTERNAL TESTS.
The second column, labeled “POSSIBLE AREAS OF
MISADJUSTMENT(S)”, lists the obvious external possibilities that may contribute to the machine symptom. Perform these tests/checks in the order listed. In general, these tests can be conducted without removing the case cover.
All of the referenced test procedures referred to in the Troubleshooting Guide are described in detail at the end of this section. Refer to the
Troubleshooting and Repair Table of Contents to locate each specific Test Procedure. All of the referred to test points, components, terminal strips, etc., can be found on the referenced electrical wiring diagrams and schematics. Refer to the Electrical Diagrams Section Table of Contents to locate the appropriate diagram.
F-2
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.
Commander 400
F-3 F-3
TROUBLESHOOTING & REPAIR
PC BOARD TROUBLESHOOTING PROCEDURES
WARNING
ELECTRIC SHOCK can kill.
Have an electrician install and service this equipment. Turn the machine OFF before working on equipment. Do not touch electrically hot parts.
Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. To avoid problems when troubleshooting and replacing PC boards, please use the following procedure:
1.
Determine to the best of your technical ability that the PC board is the most likely component causing the failure symptom.
2.
Check for loose connections at the PC board to assure that the PC board is properly connected.
3.
If the problem persists, replace the suspect PC board using standard practices to avoid static electrical damage and electrical shock. Read the warning inside the static resistant bag and perform the following procedures:
PC Board can be damaged by static electricity.
ATTENTION
Static-Sensitive
Devices
Handle only at
Static-Safe
Workstations
Reusable
Container
Do Not Destroy
• Remove your body’s static charge before opening the static-shielding bag. Wear an anti-static wrist strap. For safety, use a 1 Meg ohm resistive cord connected to a grounded part of the equipment frame.
• If you don’t have a wrist strap, touch an unpainted, grounded, part of the equipment frame.
Keep touching the frame to prevent static build-up. Be sure not to touch any electrically live parts at the same time.
• Tools which come in contact with the PC Board must be either conductive, anti-static or static-dissipative.
• Remove the PC Board from the static-shielding bag and place it directly into the equipment. Don’t set the
PC Board on or near paper, plastic or cloth which could have a static charge. If the PC Board can’t be installed immediately, put it back in the static-shielding bag.
• If the PC Board uses protective shorting jumpers, don’t remove them until installation is complete.
• If you return a PC Board to The Lincoln Electric
Company for credit, it must be in the static-shielding bag. This will prevent further damage and allow proper failure analysis.
4.
Test the machine to determine if the failure symptom has been corrected by the replacement PC board.
NOTE: Allow the machine to heat up so that all electrical components can reach their operating temperature.
5.
Remove the replacement PC board and substitute it with the original PC board to recreate the original problem.
a. If the original problem does not reappear by substituting the original board, then the
PC board was not the problem. Continue to look for bad connections in the control wiring harness, junction blocks, and terminal strips.
b. If the original problem is recreated by the substitution of the original board, then the
PC board was the problem. Reinstall the replacement PC board and test the machine.
6.
Always indicate that this procedure was followed when warranty reports are to be submitted.
NOTE: Following this procedure and writing on the warranty report, “INSTALLED AND SWITCHED PC
BOARDS TO VERIFY PROBLEM,” will help avoid denial of legitimate PC board warranty claims.
Commander 400
F-4
Observe Safety Guidelines detailed in the beginning of this manual.
F-4
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage is evident.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
RECOMMENDED
COURSE OF ACTION
Authorized Field Service Facility.
1. Contact the Lincoln Electric
Service Department. 1-800-833-
9353 (WELD).
No welding output in either CV or
Stick modes. Auxiliary power is normal and engine operates normally.
1. Place the Welding Terminals switch in the “ALWAYS ON”position. If the problem is solved, the fault may be in the external control cable (if used), Leads #2 and
#4. See the Wiring Diagram.
clamps, and electrode holder for loose or faulty connections.
3. With the engine at high idle
(1900 RPM), and the machine in the general fab tap, Check for the presence of 70VDC at the output terminals of the
Commander 400.
1. Check for loose or faulty connections on the heavy current carrying leads between the output bridge and the output terminals. Also check for broken leads at the weld choke. See the Wiring Diagram.
2. Check the welding terminal switch (S6) and leads 2 &4 back to J8 pins 2 & 3 of the control board.
3. Check for poor connections at
J6 pins 1,2 & 3 molex plug at the control PC board. Also check leads G1,G2 & G3 to each SCR.
These are SCR gate drive outputs.
4. Check leads W1 thru W6 for loose or faulty connections. See the wiring diagram.
5. Perform the Stator Voltage Test.
6. Perform the SCR/Diode Bridge
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
Commander 400
F-5
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-5
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
“---” or “CRS” stuck on display when machine is powered up. No welding output in both stick and CV modes.
Engine operates normally and auxiliary power is normal.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
Authorized Field Service shop.
RECOMMENDED
COURSE OF ACTION
1. Check for loose or faulty connections or wires at the T1, T2, or T3 capacitor connection block and back to the capacitor bank. On machines equipped with
L10953-1 Exciter feedback
Module Assembly check leads
T1, T2 & T3 for faulty connections.
2. Check for loose or faulty connections at leads 268,269, & 270 from the exciter PC board to J4 pins 1,2, & 3 on the control board.
3. Check the exciter waveforms as
illustrated in the Oscilloscope
The welding output is low with little or no control of output. The auxiliary power is OK. The engine is operating normal.
The machine has low welding output and low auxiliary output.
1. If the remote control unit is not connected to the machine, make sure the Local/Remote switch
(S1) is in the “Local” position.
2. If a remote control unit is connected, and the machine operates normally when the switch is in the “Local” position, the remote control cable or unit may be faulty. Check or replace.
1. The engine speed may be low.
Normal high idle (no load) is
1900 RPM.
1. Perform the
3. Perform the SCR/Diode Bridge
2. Perform the Stator Voltage Test.
1. If the speed is low, perform the
2. Perform the Stator Voltage Test.
3. Perform the Exciter Capacitor
4. The engine may have lost horsepower and may need major repairs.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-6
Observe Safety Guidelines detailed in the beginning of this manual.
F-6
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
Low or no constant voltage (CV) welding output. Constant current
(CC) and the auxiliary power are operating normally.
The machine powers down within seconds of power up and all lamp indicators on the front panel are lit.
“ECL”, “ECH”, or “CSS” appears on display as machine is shutting down.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
1. Make sure the wire feeder, control cable and welding cables are connected correctly.
2. Make sure the range switch is in the correct position.
3. Check the heavy current carrying cables associated with the
CV output terminal. See the
Wiring Diagram.
Authorized Field Service Shop.
2. Check for poor connections at
J21 pins 1 & 4 at the CV daughter board. This is CVSCR gate drive output. Will not affect welding in the general fab or pipe taps.
3. Check for poor connections along lead #208 at the negative
CV output stud and at the J21 pin 6 molex plug at the CV daughter board. This is CV voltage feedback input. Will not affect welding in the general fab or pipe taps.
1. Check to make sure that the machine has an L10953-1
Exciter Feedback Module Asbly.
2. Check for loose or faulty connections or wires at the T1, T2 or
T3 capacitor connection block and back to the capacitor bank.
On machines equipped with
L10953-1 Exciter Feedback
Module Asbly check leads T1,
T2 and T3 for fault connections.
3. Check for loose or faulty connections at leads 268, 269, &
270 from the exciter PC Board to
J4 pins 1, 2 & 3 on the control board.
4. If possible check exciter waveforms as illustrated in the
5. If possible perform the Exciter
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
Commander 400
F-7
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-7
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
RECOMMENDED
COURSE OF ACTION
No welding output in either CV or stick modes. Also no auxiliary power. Engine operates normally.
Authorized Field Service Shop.
1. Check for loose or faulty connections or wires at the T1, T2 or
T3 capacitor connection block and back to the capacitor bank.
On machines equipped with
L10953-1 Exciter feedback module asbly check leads T1, T2 and
T3 for faulty connections. See the Wiring Diagram.
2. Perform the Exciter Capacitor
3. Check for a short across the weld bridge plates.
4. Disconnect leads 3, 5 & 6 from the terminal block located inside the right hand side of the control box. Check for a short across each 115v and 115V/230V receptacle.
5. Check fro shorts or opens in the
stator by performing the Stator
No auxiliary power at receptacles.
The engine operates normally and the welding output is normal.
1. Check the circuit breakers CB1 thru CB4. Reset if tripped.
2. Check the GFCI receptacles.
Reset if tripped.
3. Check for loose or faulty plugs at the power receptacles.
1. Check the GFCI receptacles and associated wires for loose or faulty connections. See the
Wiring Diagram.
2. Check the continuity of leads #3,
#5, #5A and #6 from the exciter windings to their respective tie points. See the Wiring Diagram.
3. Perform the Stator Voltage Test.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-8
Observe Safety Guidelines detailed in the beginning of this manual.
F-8
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
ENGINE PROBLEMS
RECOMMENDED
COURSE OF ACTION
Engine will not idle down to low speed. Machine has normal weld and auxiliary power.
1. Make sure the Idler switch (S4) is in the “AUTO” position.
2. Make sure there is not an external load on either the weld terminals or the auxiliary receptacles.
3. Check for mechanical restriction in the solenoid linkage.
1. Perform the Idler Solenoid Test.
2. Make sure the control board mounting/grounding screws are tight.
3. Check leads #226, #227, #237 &
#254 for loose or faulty connections. See the Wiring Diagram.
4. Check solenoid waveforms as
illustrated in the Oscilloscope
5. Check to make sure that leads
#227 & #232 at the B1 & B3 terminals on the control board are not swapped. See the Wiring
Diagram.
Engine will not go to high idle when attempting to weld or use auxiliary power. Output is normal when Idler switch is in the “HIGH” position.
Automatic idle function works properly when the auxiliary power is loaded.
1. Make sure the welding cables and connections are tight.
NOTE: The automatic idler may not function if the auxiliary power is loaded to less than 150 watts.
1. Check the current sensing toroid for loose or faulty connections.
CV models only. See the Wiring
Diagram.
2. Make sure the toroid and lead assembly are assembled correctly. CV models only. See the
Wiring Diagram.
3. Check the shunt and associated leads for loose or faulty connections. Stick models only.
4. The control board may be faulty.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-9
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-9
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
The machine goes to low idle but does not stay at low idle.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
ENGINE PROBLEMS
1. Make sure there is NOT an external load (auxiliary or weld) connected to the Commander
400.
RECOMMENDED
COURSE OF ACTION
1. The idler solenoid linkage may be misadjusted or damaged.
2. The idler solenoid hold-in circuitry may be faulty. Check leads
#237 and #226 for loose or faulty connections. See the Wiring
Diagram.
3. Perform the Idler Solenoid Test.
4. Make sure the control board mounting/grounding screws are tight.
5. Check solenoid waveforms as
illustrated in the Oscilloscope
6. The control board may be faulty.
Replace.
The engine will not crank or cranks very slowly.
1. Check for loose, faulty, or corroded battery cable connections.
2. Check the leads and connections at the starter solenoid and the start push button.
3. The battery may be faulty.
1. The starter motor, solenoid or push button may be faulty.
Check or replace.
2. The engine may be hard to crank due to a mechanical failure in the engine.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
Commander 400
F-10
Observe Safety Guidelines detailed in the beginning of this manual.
F-10
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
ENGINE PROBLEMS
The engine cranks but will not start.
1. Check for adequate fuel supply.
2. Make sure the fuel shut off valve is in the open position (lever is in line with the hose).
3. The battery voltage may be too low. If it is less than 11VDC, charge or replace the battery.
Check the charging system.
4. If the engine temperature light is lit, check the engine cooling system.
The engine shuts down shortly after start. Initialize sequence is normal
(see Initialization Sequence sec-
1. Check for adequate fuel supply.
2. If any indicator light is lit when the engine shuts down, that particular system has faulted.
Check system.
3. Check for loose, faulty, or corroded battery cable connections.
4. Check the Run/Stop switch and associated leads for loose or faulty connections.
1. Check leads #274 & #240A at
J50 (exciter voltage plug) for loose or faulty connections.
See the Wiring Diagram.
2. Perform the
3. Check leads #224, #225, #240 and #262 for loose or faulty connections. See the Wiring
Diagram.
4. Make sure the control board mounting/grounding screws are tight.
5. Check solenoid waveforms as
illustrated in the Oscilloscope
6. Check to make sure that J4 &
J23 are not swapped at the control board. See the Wiring
Diagram.
1. Perform the
2. If possible check solenoid waveforms as illustrated in the
Oscilloscope Waveforms section.
3. The control board may be faulty.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-11
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-11
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
FUNCTION PROBLEMS
The battery does not stay charged.
1. Check for loose, faulty or corroded battery cable connections.
2. The battery may be faulty.
Check or replace.
The Fine Control on the
Commander 400 does not work properly.
1. Make sure the Remote/Local switch (S1) is in the “LOCAL” position.
RECOMMENDED
COURSE OF ACTION
1. Perform the Charging Circuit
3. The control board may be faulty.
Remote output control not functioning correctly.
The wire feeder does not work when connected to the machine’s
14 pin amphenol.
1. Make sure the Remote/Local switch (S1) is in the “REMOTE” position.
2. The remote control unit or cable may be faulty. Repair or replace.
1. Check the circuit breaker CB5.
Reset if tripped.
2. The wire feeder control cable may be faulty. Check or replace.
3. The wire feeder may be faulty.
Check or replace.
2. Check the Remote/Local switch
(S1) and associated leads. See the Wiring Diagram.
3. The RF Bypass PC Board (CV models) may be faulty. See the
Wiring Diagram.
The Remote Protection PC
Board (Stick models) may be faulty. See the Wiring Diagram.
4. Check amphenols and associated leads. See the Wiring
Diagram.
1. With the engine at high idle speed: Check for the presence of 115VAC at leads #31 pin “J” and #32 pin “A” at the 14 pin amphenol. If the voltage is missing or low, Check for loose or broken connections. See the
Wiring Diagram. Also check
CB5 for proper operation.
2. The RF bypass board (CV modules only) may be faulty. See the Wiring Diagram.
3. Perform the Stator Voltage Test.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-12
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-12
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
RECOMMENDED
COURSE OF ACTION
The welding arc is “cold.” The engine runs normally. The auxiliary power is normal.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
FUNCTION PROBLEMS
1. Check for loose or faulty connections at the weld output terminals and welding cable connections.
2. The welding cables may be too long or coiled, causing an excessive voltage drop.
3. Check to make sure that the machine settings match the weld application.
4. If a remote control unit is not connected to the machine, make sure the Local/Remote switch
(S1) is in the “LOCAL” position.
5. If the remote control unit is connected, and the machine operates normally when the switch is in the “LOCAL” position, the remote control cable or unit may be faulty. Check or replace.
1. Using a voltmeter, check for the correct OCV at the weld terminals. If the correct voltage is present, then check for loose connections on the heavy current carrying leads inside the machine. See the Wiring
Diagram.
2. If the OCV is low, perform the
3. Perform the SCR/Diode Bridge
4. Perform the Stator Voltage Test.
5. Perform the Range Switch Test.
7. Check fro poor connections at the J1 molex plug at the control board and at the shunt. Also,
8. Check for poor connections along lead #204A at the diode bridge and at J6 pin 4 molex at the control pc board. This is control board common.
9. Check for poor connections at
J6 pins 1, 2 & 3 molex plug at the control board. Also check leads G1, G2 & G3 to each
SCR. These are SCR gate drive outputs.
10. Check for poor connections along lead #207 at the negative
CC output stud, and at the J6 pin 10 molex plug at the control board. This is CC arc voltage feedback input. Will not affect welding in the CV tap.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-13
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-13
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
WELDING PROBLEMS
RECOMMENDED
COURSE OF ACTION
The welding arc is “cold.” The engine runs normally. The auxiliary power is normal. (Continued)
11. Check for poor connection at
J21 pins 1 & 4 at the CV daughter board. This is CVSCR gate drive output. Will not affect welding in the general fab or pipe taps.
12. Check for poor connection along lead #208 at the negative
CV output stud and at J21 pin 6 molex plug at the CV daughter board. This is CV voltage feedback input. Will not affect welding in the general fab or pipe taps.
13. Check the weld & CV chokes (if so equipped) for turn to turn shorts.
14. Check all waveforms as illus-
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-14
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-14
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The welding arc is “hot”, “spattery”,
“cannonballs” or “flares up”. The engine runs normally. The auxiliary power is normal.
WELDING PROBLEMS
1. Check to make sure that the machine settings match the weld application.
2. If the remote control unit is not connected to the machine, make sure the Local/Remote switch (S1) is in the “Local” position.
3. If a remote control unit is connected, and the machine operates normally when the switch is in the “Local” position, the remote control cable or unit may be faulty. Check or replace.
3. Check for poor connections at the J1 molex plug at the control
board. Also, perform the Shunt
4. Check for poor connections at
J4 pins 1, 2, 3, 6, & 7 at the control board. Also, perform the
5. Check for poor connections along lead #207 at the negative
CC output stud, and at J6 pin
10 molex plug at the control board. This is CC arc voltage feedback input. Will not effect welding in the CV tap.
6. Check for poor connections along lead #204A at the diode bridge and at J6 pin 4 molex plug at the control board. This is control board common.
7. Check for poor connection along lead #208 at the negative
CV output stud and at J21 pin 6 molex plug at the CV daughter board. This is CV voltage feedback input. Will not affect welding in the general fab or pipe taps.
8. Check for poor connection at
J21 pins 1 & 4 at the CV daughter board. This is CVSCR gate drive output. Will not affect welding in the general fab or pipe taps.
9. Check the weld & CV chokes (if so equipped) for turn to turn shorts.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-15
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE
F-15
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
WELDING PROBLEMS
RECOMMENDED
COURSE OF ACTION
The welding arc is “hot”, “spattery”,
“cannonballs” or “flares up”. The engine runs normally. The auxiliary power is normal. (Continued)
10. Check all waveforms as illus-
Machine shuts down while arc gouging and all lamp indicators on front panel are lit. “ECL”, “ECH”, or “CCS” appears on display as machine is shutting down.
1. Check to make sure that the machine settings match the weld application.
2. Check to make sure the propper carbon arc rod is being used. The maximum carbon arc rod for the Commander 400 is 5/16”.
3. Attempt to arc gouge at a lesser current, if the application will permit.
4. If the machine shuts down while arc gouging in the general fab tap, use the CV tap instead. This is also an acceptable process.
1. Check for poor connections at
J4 pins 1, 2, 3, 6 & 7 at the control pc board. Also, perform the
2. Check for loose or faulty connections or wires at the T1, T2, or T3 capacitor connection block and back to the capacitor bank. On machines equipped with L10953-1 Exciter
Feedback module asbly, check leads T1, T2, & T3 for faulty connections.
3. Check for loose or faulty connections at leads 268, 269 &
270 from the exciter pc board to J4 pins 1, 2 & 3 on the control board.
4. Perform the Exciter Capacitor
5. Check for poor connections at the J1 molex plug at the control pc board. Also, perform the
6. Perform the Engine Throttle
7. Check exciter waveforms as
illustrated in the Oscilloscope
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-
800-833-9353 (WELD).
COMMANDER 400
F-16
TROUBLESHOOTING & REPAIR
COMMANDER 400 INITIALIZATION SEQUENCE
AND ERROR CODE EXPLANATIONS
When the Commander 400 is started, the display flashes several messages during initialization. They usually go by so fast you cannot see them. Each message correlates to an initialization test that the microcontroller program runs. No message should be present for more than a few seconds before the next message appears. If any of these initialization messages remain on the display, there is a problem. The microcontroller’s program will not advance past that test.
The initialization period is over immediately after the “---” disappears from the display. Once past the initialization, under normal circumstances, the unit displays a welding current preset determined by the position of the front panel control knobs and switches. If a later control board (G2713-2 or -3 is in place, the message “cdr 400 rEAdy” scrolls across the display.
Initialization is over after this message finishes scrolling. In the “Stick & Wire” model a preset voltage or actual voltage, as well as current, may be displayed after initialization.
If the microcontroller detects an error, the error code will show on the display first and then the unit may shut down. Use the “Error Code Explanations” on the following pages to aid in troubleshooting diagnosis.
If the unit begins to shut down first and then the error code appears, this is not a microcontroller initiated shutdown. In this case the unit has shut down due to lack of fuel, engine failure, etc.
F-16
COMMANDER 400
F-17 F-17
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-1 CONTROL BOARD
ERROR CODES DURING
INITIALIZATION SEQUENCE
300 bAd uP
400
600
700
500 or
---
DEFINITION / SYMPTOM
Program is stuck in ROM/RAM check.
ROM/RAM is corrupt.
Program is stuck in power supply stabilization.
Program is stuck in register initialization and Interrupt enables.
Program is stuck in calibration constant loading.
The processor is not getting good initial zero crosses.
The program waits for 32 clean crosses and then waits for frequency to get between 55 and 65 HZ.
or
Program is stuck waiting for program stabilization and loading of exciter voltage register table.
CORRECTIVE ACTION
Replace control board.
Replace control board.
Replace control board.
Replace control board.
Check exciter voltage waveforms
as illustrated in the Oscilloscope
Check leads #268, #269, & #270 from J50 to J4 at the control board for loose or faulty connections. Also check the T1, T2, &
T3 lead connections from the exciter module to the stator and capacitor bank leads.
COMMANDER 400
F-18 F-18
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-1 CONTROL BOARD
ERROR CODES DURING
INITIALIZATION SEQUENCE
CSS or
ECL
DEFINITION / SYMPTOM
The processor is not receiving zero cross signals properly or the engine RPM is out of range.
or
The exciter voltage is out of range (greater than 550 or less than 140VAC).
CORRECTIVE ACTION
Check exciter voltage waveforms
as illustrated in the Oscilloscope
Check leads #268, #269, & #270 from J50 to J4 at the control board for loose or faulty connections. Also check the T1, T2, &
T3 lead connections from the
Exciter Module to the stator and capacitor bank leads.
COMMANDER 400
F-19 F-19
TROUBLESHOOTING & REPAIR
ERROR CODES DURING
INITIALIZATION SEQUENCE
LCH
DEFINITION / SYMPTOM
The output current is too high
(greater than 750 amps for more than 1 second).
Err
COMMANDER 400 WITH G2713-1 CONTROL BOARD
XIRQ error (illegal external interrupt request).
CORRECTIVE ACTION
The machine may be “over loaded.” Remove any external loads. If the problem persists with no external load, check the shunt leads and associated connections to the control board.
See the Wiring Diagram. Perform
the SCR/Diode Rectifier Bridge
If the above procedures do not reveal the problem, the control board may be faulty.
If a High Frequency unit is being used, make sure it is connected properly. There may be high frequency intrusion from another source in the immediate area.
Remove all possible forms of RF intrusion.
If the problem persists, the control board may be faulty.
COMMANDER 400
F-20 F-20
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-1 CONTROL BOARD
ERROR CODES DURING
INITIALIZATION SEQUENCE
Ert
Esi
EIO
ECP
ECE
EO5
IC3
DEFINITION / SYMPTOM
RTI error (illegal return from interrupt).
SWI error (illegal software interrupt request).
IOT error (illegal op code trap).
COP time-out error.
CME error (slow or stopped processor clock).
OC5 unintended execution.
IC3 unintended execution.
CORRECTIVE ACTION
If a High Frequency unit is being used, make sure it is connected properly. There may be high frequency intrusion from another source in the immediate area.
Remove all possible forms of RF intrusion.
If the problem persists, the control board may be faulty.
SS?
Invalid range control switch position.
Check for proper selector switch/handle alignment.
Check the selector switch and associated wiring. See the Wiring
Diagram. If the problem persists, the control board may be faulty.
COMMANDER 400
F-21 F-21
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD
ERROR CODES DURING
INITIALIZATION SEQUENCE uP bAd uP
CAL
CrS
DEFINITION / SYMPTOM
Program is stuck in ROM/RAM check.
ROM/RAM is corrupt.
Program is stuck in calibration constant loading.
The processor is not getting good initial zero crosses. Program waits for 32 clean crosses and then waits for frequency to get between 55 and 65 HZ.
Program is stuck waiting for program stabilization and loading of exciter voltage register table.
CORRECTIVE ACTION
Replace control board.
Replace control board.
Replace control board.
Check exciter voltage waveforms
as illustrated in the Oscilloscope
Check leads #268, #269, & #270 from J50 to J4 at the control board for loose or faulty connections. Also check the T1, T2, &
T3 lead connections from the
Exciter Module to the stator and capacitor bank leads.
COMMANDER 400
F-22 F-22
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD
ERROR CODES DURING
INITIALIZATION SEQUENCE
SSr
DEFINITION / SYMPTOM
Processor is not reading a valid range control switch position.
CORRECTIVE ACTION
Check for proper selector switch/handle alignment.
Perform the Range Switch Test.
EHC
ECL
CSS
The exciter voltage level is too high (greater than 550VAC).
The exciter voltage level is too low (less than 140VAC).
The processor is not receiving zero cross signals properly or the engine RPM is too high.
Check the exciter voltage waveforms as illustrated in the
Oscilloscope Waveforms Section.
Perform the Stator Voltage Exciter
Winding Test.
Perform the Engine Throttle
Adjustment Test.
Perform the Exciter Capacitor
Bank Test.
Check leads #268, #269 & #270 from J50 to J4 at the control board for loose or faulty connections. Also check the T1, T2, &
T3 lead connections from the exciter module to the stator and capacitor bank leads.
COMMANDER 400
F-23 F-23
TROUBLESHOOTING & REPAIR
ERROR CODES
WHILE RUNNING
LCH
Err
COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD
DEFINITION / SYMPTOM
The output current is too high
(greater than 750 amps for more than 1 second).
XIRQ error (illegal external interrupt request).
CORRECTIVE ACTION
The machine may be “over loaded.” Remove any external loads. If the problem persists with no external load, check the shunt leads and associated connects to the control board.
See the Wiring Diagram. Perform
the SCR/Diode Rectifier Bridge
do not reveal the problem, the control board may be faulty.
If a High Frequency unit is being used, make sure it is connected properly. There may be high frequency intrusion from another source in the immediate area.
Remove all possible forms of RF intrusion. If the problem persists, the control board may be faulty.
COMMANDER 400
F-24 F-24
TROUBLESHOOTING & REPAIR
ERROR CODES
WHILE RUNNING
LFL
SS?
COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD
DEFINITION / SYMPTOM
Unit has shut down because of low fuel.
Invalid range control switch position.
CORRECTIVE ACTION
Add more fuel. If there is less than half a tank of fuel,check for proper operation of the fuel float.
If the float is at the top of the tank, the resistance across its terminals should be less than
100 ohms. If the float is on the bottom of the tank, the resistance across its terminals should be greater than 175 ohms. If the float is OK, check the leads and connections between the float, the fuel gauge and the engine protection board. See the Wiring
Diagram. If the above checks do not reveal the problem, the engine protection board may be faulty.
Check for proper selector switch/handle alignment.
Check the selector switch and associated wiring. See the Wiring
Diagram. If the problem persists, the control board may be faulty.
COMMANDER 400
F-25 F-25
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-2 or -3 CONTROL BOARD
ERROR CODES
WHILE RUNNING
Ert
Esi
EIO
ECP
ECE
EO5
IC3
DEFINITION / SYMPTOM
RTI error (illegal return from interrupt).
SWI error (illegal software interrupt request).
IOT error (illegal op code trap).
COP time-out error.
CME error (slow or stopped processor clock).
OC5 unintended execution.
IC3 unintended execution.
CORRECTIVE ACTION
If a High Frequency unit is being used, make sure it is connected properly. There may be high frequency intrusion from another source in the immediate area.
Remove all possible forms of
RF intrusion.
If the problem persists, the control board may be faulty.
COMMANDER 400
F-26 F-26
TROUBLESHOOTING & REPAIR
COMMANDER 400 WITH G2713-2 OR -3 CONTROL BOARD
ERROR CODES WHILE
RUNNING
ECH
ECL
CSS
DEFINITION / SYMPTOM CORRECTIVE ACTION
The exciter voltage is too high
(greater than 550 VAC).
The exciter voltage is too low (less than 140 VAC).
The processor is not receiving zero cross signals properly or the engine RPM is too high.
Check exciter voltage waveforms
as illustrated in the Oscilloscope
Check leads #268, #269, & #270 from J50 to J4 at the control board for loose or faulty connections.
Also check the T1, T2, & T3 lead connections from the Exciter
Module to the stator and capacitor bank leads.
COMMANDER 400
F-27
TROUBLESHOOTING & REPAIR
CASE COVER REMOVAL AND REPLACEMENT PROCEDURE
F-27
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the case sheet metal covers.
MATERIALS NEEDED
3/8" Nut driver or Socket Wrench
7/16" Wrench
5/16" Nut Driver
This procedure takes approximately 35 minutes to perform.
COMMANDER 400
F-28 F-28
TROUBLESHOOTING & REPAIR
CASE COVER REMOVAL AND REPLACEMENT PROCEDURE
(continued)
FIGURE F.1 – DOOR CHAIN REMOVAL
DOOR
ASSEMBLY
CHAIN
PROCEDURE
1. Turn the engine off.
2. Unlatch and open engine service access door.
3. Using the 7/16" wrench, remove the chain from the door assembly. See Figure F.1
COMMANDER 400
F-29 F-29
TROUBLESHOOTING & REPAIR
CASE COVER REMOVAL AND REPLACEMENT PROCEDURE
(continued)
4. Using the 3/8" wrench, remove the three screws holding the door assembly to the left side panel. See Figure F.2.
FIGURE F.2 – DOOR ASSEMBLY/LEFT SIDE PANEL SCREW LOCATIONS
LEFT SIDE PANEL
THREE SCREWS
5. Using the 3/8" wrench, remove the two screws under the hinge. While supporting the door assembly, remove the two screws at the ends of the hinge. See Figure F.3
When these screws are removed, the door assembly will be free to fall.
FIGURE F.3 – DOOR HINGE SCREW LOCATIONS
2 SCREWS
OUTSIDE
2 SCREWS
UNDER
COMMANDER 400
F-30 F-30
TROUBLESHOOTING & REPAIR
CASE COVER REMOVAL AND REPLACEMENT PROCEDURE
(continued)
6. Carefully lift the door assembly from the machine.
7. Using the 3/8" wrench, loosen the two bottom end screws from the left side engine cover panel. See Figure F.4. Remove the center screw. Remove the panel.
FIGURE F.4 – LEFT SIDE ENGINE COVER REMOVAL
LOOSEN
TWO END SCREWS
LEFT SIDE
ENGINE COVER PANEL
REMOVE CENTER SCREW
8. Using the 3/8" wrench, remove the screws from the front roof assembly.
9. Remove the fuel cap and rubber seal.
Carefully lift and remove the front roof assembly. Replace the fuel cap.
10. Remove the screws from the lower front left and right side panels. The bottom end screws need only to be loosened.
11. Remove the panels.
Commander 400
F-31 F-31
TROUBLESHOOTING & REPAIR
CASE COVER REMOVAL AND REPLACEMENT PROCEDURE
(continued)
FRONT SHROUD REMOVAL
PROCEDURE
1. Using the 5/16" nut driver, remove the screws from the front control panel assembly. Do NOT remove the phillips head screws. Lower the panel. See Figure F.5.
FIGURE F.5 – FRONT CONTROL PANEL REMOVAL
FRONT CONTROL
PANEL LOWERED
ARROWS INDICATE
SCREW LOCATIONS
2. Using the 5/16" nut driver, remove the four screws from the left and right sides of the shroud assembly. See Figure F.6.
FIGURE F.6 – SHROUD ASSEMBLY SCREW REMOVAL - SIDES
SHROUD ASSEMBLY
REMOVE 2 SCREWS,
EACH SIDE
COMMANDER 400
F-32 F-32
TROUBLESHOOTING & REPAIR
CASE FRONT KNOBS - REMOVAL AND REPLACEMENT PROCEDURE
Removal
Side View
(Pull)
(Pull)
Knob Nameplate
Removal:
(Push)
(Push)
1. Rotate the handle portion of the knob to an approximate vertical orientation (switch detent may position handle a few degrees off vertical). This orientation should be noted and repeated at replacement for proper
"D" shaft orientation.
2. With one hand, grasp the very bottom of vertical handle and push towards the machine nameplate and pull down. At the same time and with the other hand, grasp the very top of the handle and pull the top edge of the knob away from the machine nameplate. The knob should "peel" away from the nameplate and the white nylon holding fingers of the knob base, from top to bottom.
Replacement
Rounded
Flat
Replacement:
1. If the white nylon cam of the detent mechanism is removed from it's spring loaded base by the above
procedure or intentionally, it should be returned before the knob replacement is attempted. Press the cam
into it's spring loaded holder so it sets flat and flush (Selector Switch Only).
2. Orientate the knob handle to the vertical as noted above and position the knob over the base, centered
and parallel.
3. Press the knob onto the "D" shaft and white nylon holding fingers, maintaining the parallel position.
The knob should "click" into place and should not pull off with normal operation.
COMMANDER 400
F-33
TROUBLESHOOTING & REPAIR
IDLER SOLENOID TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if the idler solenoid is capable of functioning when it is energized with
12VDC.
MATERIALS NEEDED
External 12VDC supply ( 30 amps required)
Wiring Diagram
Volt/Ohmmeter
F-33
This procedure takes approximately 40 minutes to perform.
COMMANDER 400
F-34
TROUBLESHOOTING & REPAIR
IDLER SOLENOID TEST
(continued)
FIGURE F.8 – IDLER SOLENOID LEAD TERMINALS
PULL-IN COIL
(LARGER TERMINALS
TOP AND BOTTOM
#227 AND #254)
SHUTDOWN
SOLENOID
HOLD-IN COIL
(SMALLER
TERMINALS
TOP AND BOTTOM
#226 AND #237)
IDLER
SOLENOID
TEST PROCEDURE
1. Turn the engine off.
2. Unlatch, lift and secure the right side engine service access door. Using a 5/16”, open the control panel and tilt out. Remove the control board cover.
3. Check the pull-in coil resistance by disconnecting lead #227 from the B1 terminal at the control board and measuring the resistance from lead #227 to the ground screw at the control board. Normal coil resistance is approximately 0.4 ohms. Reconnect lead
#227 to the B1 terminal at the control board.
Check the hold-in coil resistance by disconnecting J3 from the control board and measuring across pins 3 & 4. Normal coil resistance is approximately 20 ohms.
Reconnect J3 at the control board.
If either coil resistance is incorrect, the wiring may be faulty. Inspect the solenoid leads for faulty or loose connections.
If the lead connections are OK, recheck the coil resistance directly across the solenoid.
If the coil resistances are incorrect, the solenoid may be faulty. Replace.
4. Using the external 12VDC voltage supply, apply 12VDC to the larger idler solenoid terminals (#227+ to #254-). The solenoid should activate.
CAUTION
When the solenoid activates, remove the voltage supply immediately. Do not leave the external supply connected to terminals #227 and #254 for longer than three seconds. Component damage could result.
The solenoid should deactivate when the
12VDC supply is removed.
5. If the solenoid does not operate properly, check for a mechanical restriction in the linkage.
6. Using the external 12VDC voltage supply, apply 12VDC to the smaller idler solenoid terminals for the hold-in coil (#226+ to #237-).
Push in the solenoid plunger. With 12VDC applied to the hold-in coil, the plunger should stay in until the 12VDC is removed.
7. If the linkage is intact and the solenoid does not operate correctly when 12VDC is applied, the solenoid may be faulty. Replace.
8. Replace the harness leads to the correct terminals. See Figure F. 8 and the Wiring
Diagram. Replace any previously removed wire wraps.
8a. Using the control PC board layout, locate
Q21 on the control board. Scrape the environmental coating from all three legs of the device, and check the resistance between all three legs. If there is continuity between any of the legs, Q21 is bad. Replace the control PC board.
9. Close and secure the right side engine service access door. Replace the control board and close the control panel.
COMMANDER 400
F-34
F-35
TROUBLESHOOTING & REPAIR
SHUTDOWN SOLENOID TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-35
TEST DESCRIPTION
This test will determine if the shutdown solenoid is capable of functioning when it is energized with 12VDC.
MATERIALS NEEDED
External 12VDC supply ( 30 amps required)
Wiring Diagram
Volt/Ohmmeter
This procedure takes approximately 40 minutes to perform.
COMMANDER 400
F-36
TROUBLESHOOTING & REPAIR
SHUTDOWN SOLENOID TEST
(continued)
FIGURE F.9 - SHUTDOWN SOLENOID LEAD TERMINALS
PULL-IN COIL
(LARGER TERMINALS
EACH SIDE
#225 AND #262)
SHUTDOWN
SOLENOID
IDLER
SOLENOID
HOLD-IN COIL
(SMALLER TERMINALS
EACH SIDE
#224 AND #240)
TEST PROCEDURE
1. Turn the engine off.
2. Unlatch, lift and secure the right side engine service access door. Using a 5/16” nut driver, open up the control panel and tilt out.
Remove the control board cover
3. Check the pull-in coil resistance by disconnecting lead #262 from the B2 terminal at the control board and measuring the resistance from lead #262 to the ground screw at the control board. Normal coil resistance is approximately 0.4 ohms. Reconnect lead
#262 to the B2 terminal at the control board.
Check the hold-in coil resistance by disconnecting J3 & J4 from the control board and measuring across J3 pin 2 to J4 pin 5.
Normal coil resistance is approximately 20 ohms. Reconnect J3 at the control board.
If either coil resistance is incorrect, the wiring may be faulty. Inspect the solenoid leads for faulty or loose connections.
If the lead connections are OK, recheck the coil resistances directly across the solenoid.
If the coil resistances are incorrect, the solenoid may be faulty. Replace.
4. Using the external 12VDC voltage supply, apply 12VDC to the larger shutdown solenoid terminals (#262+ to #225-). The solenoid should activate.
CAUTION
When the solenoid activates, remove the voltage supply immediately. Do not leave the external supply connected to terminals #262 and #225 for longer than three seconds. Component damage could result.
The solenoid should deactivate when the
12VDC supply is removed.
5. If the solenoid does not operate properly, check for a mechanical restriction in the linkage.
6. Using the external 12VDC voltage supply, apply 12VDC to the smaller solenoid terminals for the hold-in coil, (#240+ to #224-). Push in the solenoid plunger. With 12VDC applied to the hold-in coil, the plunger should stay in until the 12VDC is removed.
7. If the linkage is intact and the solenoid does not operate correctly when 12VDC is applied, the solenoid may be faulty. Replace.
8. Replace the harness leads to the correct terminals. See Figure F.9 and the Wiring
Diagram. Replace any previously removed wire wraps.
8a. Using the control PC board layout, locate the Q25 on the control board. Scrape the environmental coating from all three legs of the device, and check the resistance between all three legs. If there is continuity between any of the legs, Q23 is bad.
Replace the control PC board.
9. Close and secure the right side engine service access door. Replace the control board cover and close the control panel.
COMMANDER 400
F-36
F-37
TROUBLESHOOTING & REPAIR
ENGINE THROTTLE ADJUSTMENT TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
If the machine output is low or high, this test will determine whether the engine is operating at the correct speed (RPM) during both HIGH and LOW idle conditions. Directions for adjusting the throttle to the correct RPM are given.
MATERIALS NEEDED
Slot head screw driver
7/16" wrench
10mm wrench
White or red marking pencil
Strobe-tach, frequency counter, or oscilloscope
3/8” wrench
F-37
This procedure takes approximately 25 minutes to perform.
COMMANDER 400
F-38
TROUBLESHOOTING & REPAIR
ENGINE THROTTLE ADJUSTMENT TEST
(continued)
FIGURE F.10 - BLOWER PADDLE MARKED FOR STROBE-TACH METHOD
F-38
MARK BLOWER
PADDLE HERE
TEST PROCEDURE
Strobe Tach Method
1.
Conduct this procedure with the engine OFF.
2.
Unlatch, lift and secure the right side engine
service access door. Perform Case Cover
Removal and Replacement Procedure
through Step 11. (For Strobe-Tach method only.)
3.
With a white or red marking pencil, place a mark on one of the blower paddles. See
Figure F.10 for location.
4.
Connect the strobe-tach according to the manufacturer's instructions.
5.
Start the engine and direct the strobe-tach light on the blower paddle. Synchronize it to the rotating mark.
With the machine at HIGH IDLE the tach should read between 1890 and 1915 RPM.
With the machine at LOW IDLE the tach should read between 1325 and 1400 RPM.
COMMANDER 400
F-39
TROUBLESHOOTING & REPAIR
ENGINE THROTTLE ADJUSTMENT TEST
(continued)
6. If either of the readings is incorrect, adjust the throttle as follows:
Adjust HIGH IDLE: Use the 10mm wrench to
loosen the locking nut. See Figure F.11 for
location of the adjusting screw and locking nut.
Turn the threaded screw counter-clockwise to increase the HIGH IDLE speed. Adjust the speed until the tach reads between 1890 and
1915 RPM. Retighten the locking nut.
Adjust LOW IDLE: First make sure there is no load on the machine. Set the IDLE switch to
AUTO and wait for the engine to change to low idle speed. Use the 7/16" wrench to loosen the
solenoid lever arm locking nut. See Figure
Adjust the collar, to change the amount of throw in the lever arm, until the tach reads between 1325 and 1400 RPM. Retighten the locking nut.
Frequency Counter Method
1. Plug the frequency counter into one of the
115 VAC auxiliary receptacles.
2. Start the engine and check the frequency counter. At HIGH IDLE (1900 RPM), the counter should read 63 Hz. At LOW IDLE
(1400 RPM), the counter should read 47 Hz.
Note that these are median measurements; hertz readings may vary slightly above or below.
3. If either of the readings is incorrect, adjust the throttle as follows:
Adjust HIGH IDLE: Use the 10mm wrench
to loosen the locking nut. See Figure F.11
for location of the adjusting screw and locking nut. Turn the threaded screw counterclockwise to increase the HIGH IDLE speed.
Adjust the speed until the frequency reads
63 Hz. Retighten the locking nut.
Adjust LOW IDLE: First make sure there is no load on the machine. Set the IDLE switch to AUTO and wait for the engine to change to low idle speed. Use the 7/16" wrench to loosen the solenoid lever arm
locking nut. See Figure F.12. Adjust the
collar, to change the amount of throw in the lever arm, until the frequency reads 47 Hz.
Retighten the locking nut.
Oscilloscope Method
1. Connect the oscilloscope to the 115 VAC receptacle, according to the manufacturer’s instructions. At HIGH IDLE (1900 RPM), the waveform should exhibit a period of 15.8
milliseconds. At 1400 RPM, the waveform should exhibit a period of 21.4 milliseconds.
Refer to the NORMAL OPEN CIRCUIT
VOLTAGE WAVEFORM (115 VAC AUXIL-
IARY) HIGH IDLE - NO LOAD in this sec-
tion of the manual.
2. If either waveform periods is incorrect, adjust the throttle as follows:
Adjust HIGH IDLE: Use the 10mm wrench
to loosen the locking nut. See Figure F.11
for location of the adjusting screw and locking nut. Turn the threaded screw counterclockwise to increase the HIGH IDLE speed.
Adjust the speed until the period is 15.8 milliseconds. Retighten the locking nut.
Adjust LOW IDLE: First make sure there is no load on the machine. Set the IDLE switch to AUTO and wait for the engine to change to low idle speed. Use the 7/16" wrench to loosen the solenoid lever arm
locking nut. See Figure F.12. Adjust the
collar, to change the amount of throw in the lever arm, until the period is 21.4 milliseconds. Retighten the locking nut.
F-39
COMMANDER 400
F-40
TROUBLESHOOTING & REPAIR
ENGINE THROTTLE ADJUSTMENT TEST
(continued)
FIGURE F.11 - HIGH IDLE ADJUSTMENT
903
BOSCH
5 7 0 0 8 1 6
PES 3A
80D 410/3R
0 400 463 12
LOCKING
NUT
F-40
ADJUSTING
SCREW
FIGURE F.12 - LOW IDLE ADJUSTMENT
903
BOSCH
5 7 0 0 8 1 6
PES 3A
80D 410/3R
0 400 463 12
ADJUSTING
COLLAR
LOCKING NUT
COMMANDER 400
F-41
TROUBLESHOOTING & REPAIR
STATIC SCR/DIODE RECTIFIER BRIDGE TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will help determine if an SCR or diode is shorted or “leaky.” See the Oscilloscope
Waveforms in this section for normal output waveforms.
MATERIALS NEEDED
Analog Volt/Ohmmeter (Multimeter)
5/16” Nut driver
3/8” Nut driver
Commander 400 Wiring Diagrams (See the Electrical Diagrams section of this manual.)
F-41
This procedure takes approximately 65 minutes to perform.
COMMANDER 400
F-42
TROUBLESHOOTING & REPAIR
STATIC SCR/DIODE RECTIFIER BRIDGE TEST
(continued)
FIGURE F.13 – CONTROL BOARD PLUG J6 LOCATION
F-42
P e l 9 9 6
PLUG J6
TEST PROCEDURE
1.
Turn off the engine.
2.
Disconnect the welding cables from the welding output terminals.
3.
Perform the Case Removal Procedure
(including front shroud removal).
4.
Using the 5/16” nut driver, remove the control board cover. See Figure F.13.
5.
Locate and remove molex plug J6 from the control board. See Figure F.13.
COMMANDER 400
F-43
TROUBLESHOOTING & REPAIR
STATIC SCR/DIODE RECTIFIER BRIDGE TEST
(continued)
FIGURE F.14 – SNUBBER BOARD PLUG J30 LOCATION
PLUG J30
F-43
WARNING
SNUBBER
BOARD
LOCATION
(LEFT SIDE,
BELOW
FUEL TANK)
C3 C1 C2 C7
COMMANDER SNUBBER
6.
Using the 3/8” nut driver, locate and remove the snubber board cover. See Figure F.14.
7.
Locate and remove molex plug J30 from the snubber board. See Figure F.14.
8.
Locate and remove lead #204B from resistor
R1 (50 ohms, 100 Watts). See Figure F.15.
FIGURE F.15 – RESISTOR R1 LOCATION
COMMANDER 400
RESISTOR R1
LEAD #204B
F-44
TROUBLESHOOTING & REPAIR
STATIC SCR/DIODE RECTIFIER BRIDGE TEST
(continued)
FIGURE F.16 – HEAT SINK AND SCR TEST POINTS
DIODE DD
DIODES DA, DB, DC
F-44
REMOVE
INSULATING PAINT
ANODE
CATHODE
9. Remove the red insulating paint from the heat sink test points. See Figure F.16.
NOTE: Do not disassemble the heat sink.
10. Measure the resistance from the anode to the cathode of SCR A, using an analog volt/ohmmeter (multimeter) set at R x 1000 scale. See Figure F.16.
a. Reverse the meter leads and measure the resistance from the cathode to the anode of SCR A. See Figure F.16.
b. If a low resistance is measured in either meter polarity, SCR A is faulty. Replace
SCR A.
11. Test the resistance of SCR B and SCR C using the same procedure described in Step
10.
12. Measure the resistance of diode DD from anode (+probe) to cathode (-probe) using an analog ohmmeter set at R x 1000 scale. The resistance should be low. See Figure F.16.
a. Reverse the meter leads and measure the resistance from cathode (+probe) to anode (-probe) of diode DD. The resistance should be high. See Figure F.16.
b. If a low resistance is measured in both meter polarities, diode DD is shorted.
Replace diode DD.
c. If a high resistance is measured in both meter polarities, diode DD is open.
Replace diode DD.
13. Test diodes DA, DB and DC for proper operation using the same procedure described in
Step 12.
14. Reconnect all leads and molex plugs.
15. If this test did not identify the problem or to
further test the SCRs, go to the Active SCR
If the test is complete, connect plug J6 to the control board and plug J30 to the snubber board and reconnect lead #204B to resistor
R1. Replace the covers to the two boards.
Replace all case covers. (See the Case
Cover Removal and Replacement proce-
dure.)
COMMANDER 400
F-45
TROUBLESHOOTING & REPAIR
ACTIVE SCR TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will help determine if the device can be gated ON and conduct current from anode to cathode.
MATERIALS NEEDED
An SCR tester as specified in this procedure.
5/16” nut driver
3/8” nut driver
Commander 400 Wiring Diagrams (See the Electrical Diagrams section of this manual.)
F-45
This procedure takes approximately 60 minutes to perform.
COMMANDER 400
F-46
PLUG J6
TROUBLESHOOTING & REPAIR
ACTIVE SCR TEST
(continued)
FIGURE F.17 – CONTROL BOARD PLUG J6 LOCATION
P e l 9 9 6
TEST PROCEDURE
1. Turn OFF the engine.
2. Perform the Case Removal procedure
(including front shroud removal).
3. Disconnect the welding cables from the welding output terminals.
4. Using the 5/16” nut driver, remove the control board cover. See Figure F.17.
5. Locate and remove molex plug J6 from the control board. See Figure F.17.
6. Using the 3/8” nut driver, locate and remove the snubber board cover. See Figure 18.
7. Locate and remove molex plug J30 from the snubber board. See Figure F.18.
FIGURE F.18 – SNUBBER BOARD PLUG J30 LOCATION
PLUG J30
WARNING
SNUBBER
BOARD
LOCATION
(LEFT SIDE,
BELOW
FUEL TANK)
C3 C1 C2 C7
COMMANDER SNUBBER
COMMANDER 400
F-46
F-47
TROUBLESHOOTING & REPAIR
ACTIVE SCR TEST
(continued)
FIGURE F.19 - RESISTOR R1 LOCATION
F-47
8. Locate and remove lead #204B from resistor R1 (50 ohms, 100 Watts). See
Figure F.19.
FIGURE F.20 - HEAT SINK TEST POINTS
RESISTOR R1
LEAD #204B
REMOVE
INSULATING PAINT
ANODE
CATHODE
9. Remove the red insulating paint from the heat sink test points. See Figure F.20.
NOTE: Do not disassemble the heat sinks.
COMMANDER 400
F-48 F-48
TROUBLESHOOTING & REPAIR
ACTIVE SCR TEST
(continued)
FIGURE F.21 - SCR TESTER CIRCUIT AND SCR CONNECTIONS
SW1 R2
+
V R1
6 VOLT
LANTERN
BATTERY
A
SCR
UNDER
TEST
C
G
SW2
R1 = 4 ohms/10 watts
R2 = 3 ohms/10 watts
To test SCRs construct the circuit outlined above. Resistor values are plus or minus ten percent. The voltmeter scale should be low, approximately 0-5 or
0-10 volts DC.
REMOVE
INSULATING
PAINT
CATHODE
ANODE
10. Construct the circuit shown in Figure F.21.
One 6-volt lantern battery can be used.
Set voltmeter scale low, at approximately
0-5 volts or 0-10 volts.
11. Test the voltage level of the battery. Short leads (A) and (C). Close switch SW-1.
Battery voltage should be 4.5 volts or higher. If lower, replace the battery.
12. Connect the tester to the SCR A as shown in Figure F.21.
a. Connect tester lead (A) to the anode.
b. Connect tester lead (C) to the cathode.
c. Connect tester lead (G) to the gate.
13. Close switch SW-1.
NOTE: Switch SW-2 should be open.
14. Read meter for zero voltage.
a. If the voltage reading is higher than zero, the SCR is shorted.
15. Close or keep closed switch SW-1.
16. Close switch SW-2 for 2 seconds. Release and read meter.
a.
If the voltage is 3-6 volts while the switch is closed and after the switch is open, the SCR is functioning.
b.
If the voltage is 3-6 volts only when the switch is closed or if there is no voltage when the switch is closed, the SCR is defective.
NOTE: Be sure the battery is functioning properly. A low battery can affect the results of the test. Repeat Battery Test Procedure in Step 11 if needed.
17. Open switch SW-1.
18. Reconnect the tester leads. See Figure
F.21.
a.
Connect tester lead (A) to the cathode.
b.
Connect tester lead (C) to the anode.
c.
Disconnect test lead (G) from the gate.
19. Close switch SW-1.
20. Read meter for zero voltage.
a.
If the voltage is zero, the SCR is functioning.
b.
If the voltage is higher than zero, the
SCR is shorted.
21. Perform the Active Test Procedure outlined in Steps 12-20 for SCRs B and C.
22. Replace all SCR assemblies that do not pass the above tests.
23. Replace all molex plugs onto the control board and snubber board. Reconnect lead
#204B resistor R1.
24. Replace the snubber board cover and control board cover.
25. Replace all case covers. (See the Case
Cover Removal and Replacement pro-
cedure.)
COMMANDER 400
F-49
TROUBLESHOOTING & REPAIR
CHARGING CIRCUIT TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if the engine alternator and associated circuitry are functioning properly.
MATERIALS NEEDED
Volt/Ohmmeter
5/16" Nut driver
3/8" Nut driver
Wiring Diagram
F-49
This procedure takes approximately 25 minutes to perform.
COMMANDER 400
F-50
TROUBLESHOOTING & REPAIR
CHARGING CIRCUIT TEST
(continued)
FIGURE F.22 – ENGINE ALTERNATOR LOCATION
F-50
#239
#285(#281)
#238
TEST PROCEDURE
1. Turn the engine off.
2. Perform the
3. Locate the engine alternator. See Figure F.22.
4. Start the engine and run it at high idle (1900
RPM).
5. Set the voltmeter for DC volts and measure the DC volts at lead #239 to engine ground.
See the Wiring Diagram. Normal is 12.5 to
14.5VDC.
6. Set the voltmeter for DC volts and measure the DC volts at lead #238 to engine ground.
See the Wiring Diagram. Normal is 12.5 to
14.5VDC.
7. Set the voltmeter for DC volts and measure the DC volts at lead #285 to engine ground.
See the Wiring Diagram. Normal is 12.5 to
14.5 VDC.
NOTE: Some earlier machines may have a lead
#281 instead of #285. Lead #285 carries the flashing voltage for the engine alternator. Battery voltage should be present whenever the engine is running. See the Wiring Diagram. On the earlier machines, lead #281 carries the flashing voltage for the engine alternator. Battery voltage should be present whenever the start button (S2) is pushed. See the Wiring Diagram.
8. If the correct flashing voltage is present and the charging output voltage is low or missing, the engine alternator may be faulty.
9. Stop the engine and check alternator V-belt for proper tension. See the engine operation manual.
10. Replace all case covers that were removed.
(See the Case Cover Removal Procedure.)
COMMANDER 400
F-51
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if the correct AC voltages are being generated from the stator windings.
MATERIALS NEEDED
Volt/Ohmmeter
3/8" Nut driver
Wiring Diagram
7/16" Wrench
F-51
This procedure takes approximately 55 minutes to perform.
COMMANDER 400
F-52
T1 STUD
#6 LEADS
T2 STUD
#5 LEADS
T3 STUD
#3 LEADS
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST
(continued)
FIGURE F.23 – CONTROL BOX STUD TERMINALS
F-52
TEST PROCEDURE – Auxiliary Power
Windings Test
1. Turn off the engine.
2. Perform the
Procedure, including front shroud removal.
For this test the control box cover will be open.
3. Start the engine and run at high idle (1900
RPM). Do NOT load welding or auxiliary power.
4. Check for 115 - 132VAC at leads 5A to 3B located at the stud terminals inside the control box. See the Wiring Diagram and Figure F.23.
If any of the above voltage checks are low or missing, check the associated leads for loose or faulty connections. See the Wiring Diagram.
Then proceed to the Exciter Winding Voltage
5. Check for 230 - 250VAC at leads 6A to 3A at the stud terminals inside the control box. See the Wiring Diagram and Figure F.23.
COMMANDER 400
F-53
W2/W5
W1/W4
W3/W6
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST
(continued)
FIGURE F.24 – SCR/DIODE RECTIFIER BRIDGE LEADS
+ COMMANDER 400
TEST PROCEDURE – Weld and PC
Board Windings Test
7. Check for 48-55VAC at leads W1/W4 to leads
W2/W5 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.
8. Check for 48 - 55VAC at leads W2/W5 to leads
W3/W6 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.
9. Check for 48 - 55VAC at leads W3/W6 to leads
W1/W4 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.
10. Check for approximately 42VAC at leads E1 to E2 located at plug J2 on the control board.
See Figure F.25. Do not remove the plug from the control board.
If any of the above voltage checks are low or missing, check the associated leads for loose or faulty connections. See the Wiring Diagram.
Then proceed to the Exciter Winding Voltage
FIGURE F.25 – CONTROL BOARD PLUG J2 LOCATION
F-53
P e l 9 9 6
PLUG J2
COMMANDER 400
F-54
T1
T2
T3
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST
(continued)
FIGURE F.26 – EXCITER LEADS T1, T2, T3
WARNING
F-54
TEST PROCEDURE – Exciter Winding
Voltage Test
11. Turn the engine off.
12. Locate the exciter leads T1, T2 and T3. See
Figure F.26.
13. Carefully pierce the insulation on leads T1,
T2 and T3 for voltage measurements.
CAUTION
Make the smallest possible puncture away from any sheet metal parts. Reinsulate these punctures at the end of this test.
14. Start the engine and run it at high idle (1900
RPM).
15. Using the voltmeter carefully check for 460
- 550VAC from T1 to T2.
16. Using the voltmeter carefully check for 460
- 550VAC from T2 to T3.
17. Using the voltmeter carefully check for 460
- 550VAC from T3 to T1.
If the Exciter Winding Voltage Test is OK and any of the other voltage checks are low or missing, the stator may be faulty. Check for "shorted" or
"grounded" windings in the stator.
If the exciter voltages are low or missing, the capacitors or associated leads may be faulty.
Check for grounded or shorted windings. See the
Wiring Diagram.
18. Replace the front shroud and all case covers
that were removed. (See the Case Cover
COMMANDER 400
F-55
TROUBLESHOOTING & REPAIR
FINE CONTROL POTENTIOMETER TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-55
DESCRIPTION
This test will determine whether the fine control potentiometer and PC board are defective.
Failure or intermediate failure of the control potentiometer circuit can result in erratic weld output or loss of weld output.
MATERIALS NEEDED
5/16” Nut Driver
Multi-Meter
Commander 400 Wiring Diagram (See the electrical diagrams section of this manual)
Control PC Board Layout (See the electrical diagrams section of this manual)
This procedure takes approximately 25 minutes to perform.
COMMANDER 400
F-56
TEST PROCEDURE
NOTE: In this test procedure, the positive output stud is used for common.
1.
Using the 5/16” nut driver, open the control panel and tilt out. Remove the control board cover.
Put the LOCAL/REMOTE switch in the “LOCAL” position. Set the range switch to the general fabrication tap. Start the machine.
WARNING
There are high voltages present inside the control box while the machine is running. THE VOLTAGES
ARE HIGH ENOUGH TO KILL. Use extreme caution to avoid the backside of the receptacles, breakers, and terminal strip while checking voltages inside the control box.
2. With the control potentiometer in the minimum position, check the voltage at the control board from J8 pin 8 to common. Voltage should be approximately -.025 VDC.
3.
Slowly turn the control potentiometer CW. The voltage should steadily increase from approximately -.025 VDC in the minimum position to
F-56
TROUBLESHOOTING AND REPAIR
FINE CONTROL POTENTIOMETER TEST (continued)
approximately 5.00 VDC in the maximum position. Also, the display on the control panel should steadily increase from 50-575.
4.
If step 2 or 3 fails, turn off the machine. At J8 pins 5,8, & 9, perform a resistance check of the fine control potentiometer (the control potentiometer is a 10K ohm potentiometer). See
Figure F.27. Also, check continuity of all fine control potentiometer leads and LOCAL/REMOTE switch. If any of the leads, switch or potentiometer fails the resistance check, replace the faulty component.
5.
If the leads, switch and potentiometer pass the resistance check, disconnect the J8 from the control board and start the machine. Check the voltage from J8 pin 9 to common. The voltage should be approximately 5.11 VDC. Check the voltage from J8 pin 5 to common. The voltage should be approximately -.049 VDC. If either voltage check fails, replace the PC board.
6.
Repeat steps 2-4 with the LOCAL/REMOTE switch in the “REMOTE” position and a remote control potentiometer hooked up to either amphenol. When doing any continuity checks, be sure to include the RF bypass PC board and associated leads.
7.
When the test is complete, replace the control board cover and close the control panel.
Figure F.27 Control Board Plug J8 location
Pin #5
C112
J2
J6
J5
J20
J8 J7
J1
J4
J22
Pin #8 Pin #9
Plug J8
COMMANDER 400
F-57
TROUBLESHOOTING & REPAIR
RANGE SWITCH TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-57
DESCRIPTION
This test will determine whether the range switch is defective. Failure or intermittent failure of the range switch can cause erratic weld output.
MATERIALS NEEDED
5/16” Nut Driver
Multi-Meter
Commander 400 Wiring Diagram (See the electrical diagrams section of this manual)
Control PC Board Layout (See the electrical diagrams section of this manual)
This procedure takes approximately 30 minutes to perform.
COMMANDER 400
F-58 F-58
TROUBLESHOOTING AND REPAIR
RANGE SWITCH TEST (continued)
TEST PROCEDURE
NOTE: In this test procedure, the positive output stud is used for common.
1.
Using the 5/16” nut driver, open the control panel and tilt out. Remove the control board cover.
Start the machine.
WARNING
There are high voltages present inside the control box while the machine is running. THE VOLTAGES ARE HIGH
ENOUGH TO KILL. Use extreme caution to avoid the backside of the receptacles, breakers, and terminal strip while checking voltages inside the control box.
2. Put the range switch in the CV position on stick & wire machines, or in the 90 tap on stick only machines.
3.
Check the voltage at the control board from J7 pin 10 to common at each tap on the range
switch. See Figure F.28. See table F.1 below for
approximate voltage reading from each tap.
4.
If any of the voltages in the table are incorrect, replace the range switch.
5.
If the test is complete, replace the control board cover and close the control panel.
Range Switch Position
CV tap
90 tap
120 tap
180 tap
230 tap
270 tap
400 tap
50-575 tap
Table F.1
Voltage
.580 Vdc (if so equipped)
.937 Vdc
1.29 Vdc
1.65 Vdc
2.00 Vdc
2.36 Vdc
2.69 Vdc
3.06 Vdc
COMMANDER 400
F-59
TROUBLESHOOTING & REPAIR
RANGE SWITCH TEST (continued)
Figure F.28 Control Board Plug J7
F-59
C112
J2
J6
J5
Pin #1
J20
J8 J7
J1
J4
J22
Plug J7
Pin #7
Pin #10
COMMANDER 400
F-60
NOTES
F-60
COMMANDER 400
F-61
TROUBLESHOOTING & REPAIR
SHUNT CALIBRATION TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-61
DESCRIPTION
This test will determine whether the 600 amp shunt is out of calibration.
MATERIALS NEEDED
5/16” Nut Driver
Multi-Meter
Resistive Grid Bank
Commander 400 Wiring Diagram (See the electrical diagrams section of this manual)
Control PC Board Layout (See the electrical diagrams section of this manual)
This procedure takes approximately 40 minutes to perform.
COMMANDER 400
F-62 F-62
TROUBLESHOOTING AND REPAIR
SHUNT CALIBRATION TEST (continued)
TEST PROCEDURE
NOTE: In this test procedure, the positive output stud is used for common.
1.
Using the 5/16” nut driver, open the control panel and tilt out. Remove the control board cover.
Start the machine.
WARNING
There are high voltages present inside the control box while the machine is running. THE VOLTAGES
ARE HIGH ENOUGH TO KILL. Use extreme caution to avoid the backside of the receptacles, breakers, and terminal strip while checking voltages inside the control box.
2. Set the range switch to the CC/General fabrication tap. Using the fine control pot, set the preset amps on the display to 300 amps.
3.
Using a grid bank, load the machine to 300 amps at 25 volts using an external ammeter and voltmeter.
4.
At the control board, measure the voltage from
J1 pin 3 (pos. lead) to J1 pin 2 (neg. lead). See
Figure F.29. The voltage should be 25 mVDC +/-
5%. The current reading on the display should be within +/- 5% with the external ammeter. See
Figure F.29.
5.
If step 4 fails, the shunt is out of calibration and must be replaced.
6.
If the test is complete, replace the control board cover and close the control panel.
Figure F.29 Control Board Plug J1
C112
J20 J22
J2
J6 J5
J8 J7
J1
J4
Plug J1
-Pin #2
+Pin #3
COMMANDER 400
F-63
TROUBLESHOOTING & REPAIR
EXCITER VOLTAGE FEEDBACK TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-63
DESCRIPTION
This test will determine whether the exciter voltage module is reading each exciter phase voltage back to the control board accurately. An inaccurate reading can cause the control board to shut down the machine with an “ECH” or “ECL” error code when operating the machine at high currents.
MATERIALS NEEDED
None
This procedure takes approximately 20 minutes to perform.
COMMANDER 400
F-64 F-64
TROUBLESHOOTING AND REPAIR
EXCITER VOLTAGE FEEDBACK TEST (continued)
TEST PROCEDURE
1.
Set the machine to the following settings, then start the machine:
Control dial to 1 (min)
Range dial to 90A max
Idler switch in the “Auto” position
Output control source (2-4) switch in the
“Welding Terminals Remotely Controlled” position.
2.
As the unit powers up, the display will step thru its’ initialization sequence. As soon as the display shows “---”, the user must toggle the idler switch from “Auto” to “High” 5 times in 5 seconds. The display will read “tal”, then “000”. The idler switch must be returned to the “Auto” position. If the user misses toggling the Idler switch
5 times in 5 seconds, the machine will default to normal operation, and step 1 & 2 must be repeated.
3.
Toggle the 2-4 switch to the “Welding Terminals
Always On” position. The display will read the phase 1 no load exciter voltage. The voltage should be between 400-525 Vac. Return the 2-4 switch to the “Welding Terminals Remotely
Controlled” position.
4.
Toggle the Idler switch from “Auto” to “High”, then back to “Auto”. The display should read
“001”. Repeat step 3 to read the phase 2 no load exciter voltage.
5.
Toggle the idler switch from “Auto” to “High”, then back to “Auto”. The display should read
“002”. Repeat step 3 to read the phase 3 no load exciter voltage.
6.
For machines equipped with G2713-1 boards, toggle the Idler switch once from “Auto” to
“High”. The display should read “003”. For machines equipped with G2713-2 & 3 boards, toggle the idler switch 3 times from “Auto” to
“High” to “Auto” till the display reads “000” again.
7.
Turn the control dial to 10 (max). Toggle the 2-4 switch to the “Welding Terminals Always On” position. Apply a grid load so that the machine’s output is 565-585 amps at a minimum of 30 VDC.
The display will read the phase 1 exciter voltage under load. Record the phase 1 exciter voltage under load. Return the 2-4 switch to the
“Welding Terminals Remotely Controlled” position.
8.
Toggle the Idler switch from “Auto” to “High”, then back to “Auto”. The display should read
“001” (or “004” for machines equipped with
G2713-1 board). Repeat step 7 to read the phase 2 exciter voltage under load.
9.
Toggle the idler switch from “Auto” to “High”, then back to “Auto”. The display should read
“002” (or “005” for machines equipped with
G2713-1 board). Repeat step 7 to read the phase 3 exciter voltage under load.
10. If all exciter voltage readings on the display are correct, the exciter board is properly calibrated and the test is complete. If the average of the three exciter voltage readings under load is under
350VAC, then the board must be replaced.
COMMANDER 400
F-65
TROUBLESHOOTING & REPAIR
EXCITER CAPACITOR BANK TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-65
DESCRIPTION
This test will determine whether there are any bad capacitors in the exciter capacitor bank.
Low capacitance in the bank can cause lack of full weld output and can cause the control board to shut down the machine with an “ECH” or “ECL” error code when operating the machine at high currents.
MATERIALS NEEDED
Refer to “Case Cover Removal” section for tools needed to remove side panels.
Capacitance Meter
7/16” Nut Driver
Crescent Wrench
This procedure takes approximately 35 minutes to perform.
COMMANDER 400
F-66 F-66
TROUBLESHOOTING AND REPAIR
EXCITER CAPACITOR BANK TEST (continued)
WARNING
Check for voltage across capacitors.
Voltages could be high and dangerous. Discharge capacitors with a high wattage (50 Ohm min.) resistor if necessary before performing tests.
TEST PROCEDURE
1.
With the engine off, disconnect the negative battery cable.
2.
Refer to the “Case Cover Removal” section and
remove the left side engine and stator cover panel.
3.
Locate the point at which the capacitor bank leads are bolted to the T1, T2, & T3 leads coming from the stator and L10953-1 exciter feedback module. See Figure F.30.
4.
Pull the sleeving back and disconnect the three bolted exciter connections using a 7/16” nut driver and crescent wrench.
5.
Measure capacitance from multi-lead
1002/1004/1006/1008 to multi-lead
1001/1003/1005/1007 with a capacitance meter.
The capacitance value should be 240 uf +/- 5%.
6.
Measure capacitance from multi-lead
1018/1020/1022/1024 to multi-lead
1017/1019/1021/1023 with a capacitance meter.
The capacitance value should be 240 uf +/- 5%.
7.
Measure capacitance from multi-lead
1010/1012/1014/1016 to multi-lead
1009/1011/1013/1015 with a capacitance meter.
The capacitance value should be 240 uf +/- 5%.
8.
If any of the capacitance values in steps 5-7 are incorrect, then all the capacitors in that phase must be replaced.
9.
If the test is complete, reconnect the 3 bolted connections for the T1,T2, & T3 leads from the stator and exciter module, and capacitor leads.
Make sure that the T1,T2, & T3 stator leads are matched to the T1,T2,& T3 leads from the exciter module respectively. Mismatching the leads will cause the “---” or “CRS” to be stuck on the display at power up, and no weld output. Cover each bolted connection with sleeving after reconnection.
10. Reinstall the left side engine and stator cover
panels per the “Case Cover Removal” section.
Figure F.30 Control Board Plug J1
WARNING
T1
T2
T3
COMMANDER 400
F-67
TROUBLESHOOTING & REPAIR
CONTROL BOARD POWER SUPPLY TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-67
DESCRIPTION
This test will determine whether the weld control power supply from the control board that supplies power to the weld control circuit, display, 2-4 switch circuit, and CV SCR drive circuit is defective. A defective power supply can cause loss of weld output and loss of weld control.
MATERIALS NEEDED
5/16” Nut Driver
Multi-Meter
Commander 400 Wiring Diagram (See the electrical diagrams section of this manual)
Control PC Board layout (See the electrical diagrams section of this manual)
This procedure takes approximately 40 minutes to perform.
COMMANDER 400
F-68 F-68
TROUBLESHOOTING AND REPAIR
CONTROL BOARD POWER SUPPLY TEST (continued)
TEST PROCEDURE
NOTE 1: In this test procedure, the positive output stud is used for common.
NOTE 2: This test procedure does not test the engine control power supply portion of the control board.
1.
Using the 5/16” nut driver, open the control panel and tilt out. Remove the control board cover.
2. Using the control PC board layout, locate capacitor C112 (Figure F.31) and scrape the environmental coating off the negative lead. Start the machine.
WARNING
There are high voltages present inside the control box while the machine is running. THE VOLTAGES ARE HIGH
ENOUGH TO KILL. Use extreme caution to avoid the backside of the receptacles, breakers, and terminal strip while checking voltages inside the control box.
3.
Refer to the Stator Voltage Test, step 10, to test
the E1-E2 stator winding that powers the control
PC board. If the voltage is correct, proceed to step 4. If the voltage is incorrect, shut down the machine, unplug J2, restart the machine, and check the voltage again at J2 pins 1 to 4. If the voltage is still incorrect, abort the “Control Board
Power Supply Test” and proceed to the “Stator
Resistance Test”.
4.
With the machine running, measure the voltages at the control board per the following table.
5.
If any of the voltage checks in the Table F.2 below are incorrect, replace the control board.
6.
If the test is complete, replace the control board cover and close the control panel.
Measurement Point
J5 pin 2 to common
J4 pin 6 to common
J5 pin 7 to common
C112 neg. lead to common
J8 pin 2 to J8 pin 3
J20 pin 3 to J20 pin 4
Table F.2
Voltage
15 VDC +/- 5%
10 VDC +/- 5%
5 VDC +/- 5%
-10 VDC +/- 5%
24 VDC +/- 5%
15 VDC +/- 5%
Description
+15V supply for display
+10V supply for weld control & exciter module
+5V supply for microprocessor
-10V supply for weld control
+24V supply for 2-4 circuit
+15V supply for CV SCR gate drive circuit
Figure F.31 Control Board Plugs C112 & J2
C112
Pin #1 Pin #2
C112
J2
J6
J5
J20 J22
J8 J7
J1
J4
COMMANDER 400
Pin #3 Pin #4
Plug J2
F-69
TROUBLESHOOTING & REPAIR
STATOR RESISTANCE TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-69
DESCRIPTION
This test will determine whether there are shorts, opens, or grounds in any of the stator windings. An open, shorted or grounded winding can cause lack of output.
MATERIALS NEEDED
Refer to “Case Cover Removal” section for tools needed to remove side panels and shroud.
5/16” Nut Driver
7/16” Nut Driver
2 Multi-Meters
Crescent Wrench
This procedure takes approximately 45 minutes to perform.
COMMANDER 400
F-70 F-70
TROUBLESHOOTING AND REPAIR
STATOR RESISTANCE TEST (continued)
TEST PROCEDURE
1.
With the engine off, disconnect the negative battery cable. Make sure that there is nothing plugged into the 115V and 230V receptacles.
2.
Using the 5/16” nut driver, open up the control panel and tilt out. Remove the control board cover.
3.
Refer to the “Case Cover Removal” section and remove left side engine and stator cover panels, and the front shroud.
4.
Pull the sleeving back, and disconnect all weld leads (W1-W6) from the SCR/Diode weld bridge using the 7/16” nut driver and crescent wrench.
5.
Locate the point at which the capacitor bank leads are bolted to the T1,T2 & T3 leads coming from the stator and L10953-1 exciter module.
Pull the sleeving back and disconnect the three bolted exciter connections using a 7/16” nut driver and crescent wrench.
6.
Disconnect J2 from the control board.
7.
Using an Ohmmeter check for continuity between each weld lead (W1-W6) to the T1 exciter lead. There should be no continuity between these leads.
8.
Check for continuity from the weld leads to the
J2 plug pins 1 & 2 at the control board. There should be no continuity between these leads.
9.
Check for continuity from the weld leads to frame ground. There should be no continuity between these leads.
10. Check for continuity from J2 pins 1 & 4 to the T1 exciter lead. There should be no continuity between these leads.
11. Check for continuity from J2 pins 1 & 4 to frame ground. There should be no continuity between these leads.
12. Construct the circuit shown below. See Figure
F.32.
Figure F.32
V1
S1
12V
CAR
BATTERY
J50
1 OHM
300 W
VOLTAGE LEADS MUST
BE TO THE WINDING
SIDE OF THIS CONNECTION
V2
STATOR
WINDING
UNDER
TEST
COMMANDER 400
J51
F-71 F-71
TROUBLESHOOTING AND REPAIR
STATOR RESISTANCE TEST (continued)
TEST PROCEDURE
14. Connect the test leads J50 and J51 to the stator winding under test. Close S1 and read the voltages at V1 and V2, then open S1 IMMEDIATELY.
Damage can occur to the stator winding under test if S1 is left in the “on” position for too long.
CAUTION: The 1 ohm resistor will also become hot very quickly and can burn to the touch.
Leaving the circuit on for too long can also cause the winding to heat up causing errors in measurements.
15. Use the following equation to determine the winding resistance:
V2/V1 = winding resistance in ohms.
16. Disconnect J50 and J51 from the stator winding under test. Check the resistance of all the stator windings by repeating steps 13 & 14 and using
Table F.3 below.
Table F.3
Stator Winding Under Test
W1 - W2
W3 - W4
W5 - W6
T1 - T2
T2 - T3
T3 -T1
E1 - E2 (J2 Plug)
NOTE: The resistances in the above table are to be measured with the windings at an approximate temperature of 25 degrees Celsius
(room temp.). Measuring after the windings are heated up can cause errors in the above table.
17. If any of the continuity checks fail in steps 7 thru
16, then the stator is bad. Replace.
Resistance
.009 ohms +/- 20%
.009 ohms +/- 20%
.009 ohms +/- 20%
.130 ohms +/- 20%
.130 ohms +/- 20%
.130 ohms +/- 20%
.170 ohms +/- 20%
18. If the test is complete, reconnect the 3 bolted connections for the T1, T2, & T3 leads from the stator and exciter module, and capacitor leads.
Make sure that the T1, T2, & T3 stator leads are matched to the T1, T2, & T3 leads from the exciter module respectively. Mismatching the leads will cause the “---” or “CRS” to be stuck on the display at power up, and no weld output.
Cover each bolted connection with sleeving after reconnection. Replace Plug J2. Reinstall the left side engine and stator cover panels and the front
shroud per the “Case Cover Removal” section.
COMMANDER 400
F-72
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
HIGH IDLE – NO LOAD – OUTPUT CURRENT CONTROL AT MAXIMUM
F-72
15.8 ms
0 volts
This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
F-73
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)
MAX TAP – MAX CONTROL POT – HIGH IDLE – NO LOAD
F-73
0 volts
This is the typical DC open circuit output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at
“STICK” welding output terminals.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
F-74
TROUBLESHOOTING & REPAIR
NORMAL WELD VOLTAGE WAVEFORM (STICK CC)
MACHINE LOADED TO 400AMPS AT 40 VOLTS
F-74
0 volts
This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.
The machine was loaded with a resistance grid bank to 400 amps at
40 volts.
Note: Scope probes connected at
“STICK” welding output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
F-75
TROUBLESHOOTING & REPAIR
NORMAL WELD VOLTAGE WAVEFORM (WIRE CV)
MACHINE LOADED TO 400AMPS AT 40 VOLTS
F-75
0 volts
This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.
The machine was loaded with a resistance grid bank to 400 amps at
40 volts.
Note: Scope probes connected at
“WIRE” welding output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
F-76
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (WIRE CV TAP)
MAX CONTROL POT – HIGH IDLE – NO LOAD
F-76
0 volts
This is the typical DC open circuit output voltage generated from a properly operating machine. Note that each vertical division represents
20 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at
“WIRE” welding output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
F-77
TROUBLESHOOTING & REPAIR
NORMAL SOLENOID PULL & HOLD COIL WAVEFORMS
F-77
2 V 2 V
The scope pictures above are typical waveforms seen directly across the pull and hold terminals on both the
Idle and Shutdown solenoids when they are operating normally.
Note: Voltages across the shutdown solenoid coils may be slightly lower than these waveforms since the engine alternator may not be running.
SCOPE SETTINGS
Volts/Div.......................2V/Div.
Horizontal ..............100ms/Div.
Coupling.............................DC
Trigger.........................Internal
COMMANDER 400
100 ms
F-78
TROUBLESHOOTING & REPAIR
ABNORMAL SOLENOID PULL & HOLD COIL WAVEFORMS
F-78
1V
SCOPE SETTINGS
Volts/Div.......................1V/Div.
Horizontal Sweep ...20 ms/Div.
Coupling.............................DC
Trigger.........................Internal
200 MV
SCOPE SETTINGS
Volts/Div...............200 MV/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
5 ms
The scope pictures above are examples of a short at the output of both the pull and the hold coil circuits on the control PC board. The overcurrent circuits in the pull and hold coil circuits will shut down the circuit when an overcurrent is sensed, preventing damage to the circuit. The waveform on the left will cause the solenoid to not pull in. The waveform on the right will cause the solenoid to pull in, then drop out. Check for shorted solenoid coils and grounded leads.
COMMANDER 400
F-79
TROUBLESHOOTING & REPAIR
TYPICAL EXCITER VOLTAGE FEEDBACK WAVEFORMS
F-79
1 V
This is the typical waveform output from each of the three phases from the Exciter Feedback Module
(L10953-1) at high idle/no load under normal operation. The peak should measure between 3.5 - 4.5 Vdc, and the period should measure approximately 8.0 - 9.0 ms (make sure that the machine is set up to the proper high idle rpm before making this measurement by performing the
Engine Throttle Adjustment Test).
This waveform can be viewed at the following points on the control board:
J4 pin 1 to pin 7
J4 pin 2 to pin 7
J4 pin 3 to pin 7
SCOPE SETTINGS
Volts/Div.......................1V/Div.
Horizontal ..................2ms/Div.
Coupling.............................DC
Trigger.........................Internal
2 ms
COMMANDER 400
F-80
TROUBLESHOOTING & REPAIR
ABNORMAL EXCITER VOLTAGE FEEDBACK WAVEFORMS
F-80
1 V
This is an example of a bad waveform at one of the Exciter Module outputs (J4 pin 3 to pin 7).
Note: The distortion in the waveform that causes the period to be in excess of 9.5 ms. Any distortion that causes a period in excess of 9.0 ms requires the
Exciter Module to be replaced.
This distorted waveform can cause machine shutdowns with “CSS”, “ECL”, & “ECH” error codes on the display, and can cause “CRS” and “---” error codes at power-up. It can also cause flare-ups and welds that are too hot, “spattery”, or “cannon balling”.
SCOPE SETTINGS
Volts/Div.......................1V/Div.
Horizontal ..................2ms/Div.
Coupling.............................DC
Trigger.........................Internal
2 ms
COMMANDER 400
F-81
TROUBLESHOOTING & REPAIR
CONTROL PC BOARD REMOVAL, REPLACEMENT,
AND CALIBRATION
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the control printed circuit board. Stick and wire models also require a calibration procedure whenever a control board is replaced. This procedure is provided here following the reassembly steps.
MATERIALS NEEDED
5/16" Nut driver
Phillips head screw driver
Volt/ohmmeter (for stick and wire model calibration only)
F-81
This procedure takes approximately 40 minutes to perform.
COMMANDER 400
F-82
TROUBLESHOOTING & REPAIR
CONTROL PC BOARD REMOVAL AND REPLACEMENT
(continued)
FIGURE F.33 – MOLEX PLUG REMOVAL
F-82
ENGINE PROTECTION
BOARD MOLEX PLUG
CV BOARD
MOLEX PLUG
CONTROL BOARD
MOLEX PLUGS
P e l 9 9 6
PROCEDURE
Before starting the following procedure, refer to
the topic “PC Board Troubleshooting
Procedures” at the beginning of this section.
1. Turn off the engine.
2. Using the 5/16" nut driver, remove the front control cover assembly.
3. Using the 5/16" nut driver, remove the control board cover.
4. Locate and carefully remove the molex type plugs from the control board, engine protection board and CV board (if used). See Figure
F.33 and the Wiring Diagram.
COMMANDER 400
F-83
TROUBLESHOOTING & REPAIR
CONTROL PC BOARD REMOVAL AND REPLACEMENT
(continued)
FIGURE F.34 – CONTROL BOARD LEADS
F-83
P e l 9 9 6
B1/227
B2/262
B3/232
5. Remove lead #227 from terminal B1 on the control board. See Figure F. 34.
6. Remove lead # 262 from terminal B2 on the control board. See Figure F.34.
7. Remove lead #232 from terminal B3 on the control board. See Figure F.34.
8. Note lead placement and routing through insulation for reassembly.
9. Using the phillips head screw driver, remove the control board mounting screws. Note the location of the different types of screws for reassembly. The machine screws have lock washers and flat washers, and they mount the board to welded nuts. The sheet metal screws mount to the nylon standoffs.
10. Carefully remove the control board assembly.
Note insulation placement for reassembly.
11. Using the phillips head screw driver, carefully remove the engine protection board and
CV board (if used).
REASSEMBLY
12. Using the phillips head screw driver, carefully assemble the engine protection board and
CV board (if used) to the new control board.
13. Carefully fit the control board assembly in place. Note insulation placement.
14. Using the phillips head screw driver, mount the control board with the appropriate mounting screws. The machine screws have lock washers and flat washers, and they mount the board to welded nuts. Make sure these are secure since they are used to ground the control board. The sheet metal screws mount to the nylon standoffs.
15. Attach the leads to the control board. Note lead placement and routing through insulation.
Lead #227 to terminal B1. See Figure F. 34.
Lead # 262 to terminal B2. See Figure F.34.
Lead #232 to terminal B3. See Figure F.34.
16. Carefully connect the molex type plugs to the control board, engine protection board and
CV board (if used). See Figure F.33 and the
Wiring Diagram.
17. Using the 5/16" nut driver, install the control board cover and the front control cover assembly.
18. Perform the following calibration procedure.
COMMANDER 400
F-84
TROUBLESHOOTING & REPAIR
CONTROL PC BOARD REMOVAL AND REPLACEMENT
(continued)
F-84
CALIBRATION PROCEDURE
(Stick and Wire Model Only)
1.
Set the front control panel as follows:
”Control” dial to 0 (Min.).
“Range” dial to the ‘Wire Welding’ setting.
“Idler” switch in the “Auto” position.
“Volts/Amps” switch to the ‘volts’ position.
“Output Control switch to the “Welding
Terminals Remotely Controlled” position.
2.
Connect the volt/ohm meter across the “+” and “- WIRE” (CV) terminals.
3.
Start the unit.
WARNING
While the unit is running there are high voltages present inside the control box. THE VOLTAGES
ARE HIGH ENOUGH TO
KILL. Keep hands out of the control box while the unit is running.
to “AUTO.” The display should read “003.”
8.
Set the Output Control switch to the “WELD-
ING TERMINALS ALWAYS ON” position.
9.
Turn the “Control” dial until the display reads
“19.0.” Assure that there is no load applied to the unit.
10. Toggle the “Idler” switch to “HIGH” and back to “AUTO” continually until the voltage on the voltmeter across the studs reads 19.0 ± .2
volts. If 19.0 ± .2 volts is passed by, continue to toggle the “Idler” switch to “HIGH” and back to “AUTO” and the voltage will eventually wrap around to a value below 19 volts.
Continue to toggle the “idler” switch and try to attain 19.0 ± .2 volts again. Once the voltage across the terminals does read 19.0 ± .2 volts, proceed to the next step.
11. Set the Output Control switch to the ‘WELD-
ING TERMINALS REMOTELY CON-
TROLLED” position.
12. You have now completed the calibration procedure. Disconnect the volt/ohmmeter.
4.
As the unit begins to run, the display will step quickly through its initialization sequence. As soon as the display shows three dashes
(“---”) begin to toggle the “Idler” switch from
“AUTO” to “HIGH”. You must toggle the switch a total of 5 times in 5 seconds from the time that the dashes appeared on the display.
Failure to due so will result in the unit defaulting to normal operation. The switch must be returned to the “AUTO” position once the test mode has been accessed. The display should read “000”, indicating the step number of the self test to be executed.
5.
Toggle the “idler” switch to “HIGH” and back to “AUTO.” The display should read “001.”
6.
Toggle the “idler” switch to “HIGH” and back to “AUTO.” The display should read “002.”
7.
Toggle the “idler” switch to “HIGH” and back
COMMANDER 400
F-85
TROUBLESHOOTING & REPAIR
SHUTDOWN SOLENOID REMOVAL AND REPLACEMENT
F-85
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the shutdown solenoid.
MATERIALS NEEDED
7/16" Wrench
Long slot head screw driver
Needle nose pliers
This procedure takes approximately 60 minutes to perform.
COMMANDER 400
F-86
TROUBLESHOOTING & REPAIR
SHUTDOWN SOLENOID REMOVAL AND REPLACEMENT
(continued)
FIGURE F.35 – SHUTDOWN SOLENOID LEAD CONNECTIONS
F-86
PULL-IN COIL
(LARGER TERMINALS
EACH SIDE
#225 AND #262)
SHUTDOWN
SOLENOID
IDLER
SOLENOID
HOLD-IN COIL
(SMALLER TERMINALS
EACH SIDE
#224 AND #240)
PROCEDURE
1. Turn the engine off.
2. Unlatch, lift and secure the right side engine access door.
3. Locate and remove the four spade connectors that attach the shutdown solenoid terminals to the wiring harness leads (#224, #240, #225 and #262). See Figure F.35. Cut the cable tie.
COMMANDER 400
F-87
TROUBLESHOOTING & REPAIR
SHUTDOWN SOLENOID REMOVAL AND REPLACEMENT
(continued)
FIGURE F.36 – SHUTDOWN SOLENOID LINKAGE ARM ASSEMBLY
F-87
MOUNTING
FASTENERS
PIVOT PIN
SPACER
WASHER
PLAIN
WASHER
RETAINING
RING
4. Using the 7/16" wrench, remove the three nuts, two bolts and three lock washers mounting the shutdown solenoid assembly to the engine. See Figure F.36.
5. Using the long screw driver and needle nose pliers, carefully remove the retaining ring, plain washer, spacer washer and pivot pin from the linkage arm assembly. See Figure
F.36.
6. Carefully remove the solenoid assembly.
7. Replace any faulty parts and reassemble the solenoid assembly.
REASSEMBLY
8. Using the long screw driver and needle nose pliers, carefully assemble the retaining ring, plain washer, spacer washer and pivot pin to the linkage arm assembly. See figure F.36.
9. Using the 7/16" wrench, mount the shutdown solenoid assembly to the engine with three nuts, two bolts and three lock washers.
10. Attach the four spade connectors from the wiring harness leads (#224, #240, #225 and
#262) to the shutdown solenoid terminals.
See Figure F.35. Replace the cable tie.
11. Close the right side engine access door.
COMMANDER 400
F-88
NOTES
F-88
COMMANDER 400
F-89
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
REMOVAL AND REPLACEMENT
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-89
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the SCR/Diode rectifier bridge assembly.
MATERIALS NEEDED
5/16" Nut driver
3/8" Wrench
1/2" Wrench
3/4" Wrench
11/32" Wrench
This procedure takes approximately 80 minutes to perform.
COMMANDER 400
F-90
SHUNT
REMOVE BOLT
AT POSITIVE
HEAT SINK
PLATE (LOWER)
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
REMOVAL AND REPLACEMENT
(continued)
FIGURE F.37 – SCR/DIODE RECTIFIER BRIDGE DETAILS
+ COMMANDER 400
#209 (small)
#209A (large)
#204C
F-90
STATOR WELD
WINDING LEADS
PROCEDURE
1. Turn the engine off.
2. Perform the
Procedure (including front shroud removal).
3. Using the 1/2" wrench, remove the stator weld winding leads from the SCR/diode rectifier bridge assembly. See Figure F.37 and the
Wiring Diagram. Cut any necessary cable ties and clear the leads.
4. Using the 1/2" wrench, remove lead #209
(small) and #209A (large) from the negative
(upper) heat sink plate. See Figure F.37 and the Wiring Diagram.
5. Using the 1/2" wrench, remove the heavy
#204C lead from the positive heat sink plate
(lower). See Figure F.37 and the Wiring
Diagram.
6. Using the 1/2" wrench, remove the shunt from the positive heat sink plate (lower). See
Figure F.37 and the Wiring Diagram.
NOTE: The "DD" diode pigtail lead and the three small #204, #204A and #204B leads are also incorporated in the bolted connection. They can stay in place.
7. Using the 5/16" nut driver, remove the control board cover.
8. Remove plug J6 and the toroid assembly from the control board. Remove plug J6 and leads from the control box. Cut any necessary cable ties.
COMMANDER 400
F-91 F-91
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
REMOVAL AND REPLACEMENT
(continued)
FIGURE F.38 – NEGATIVE “STICK” OUTPUT TERMINAL
+ COMMANDER 400
#207 FROM STICK
OUTPUT TERMINAL
9. Using the 3/4" wrench, remove lead #207 from the negative "stick" output terminal. See
Figure F.38 and the Wiring Diagram. Cut any necessary cable ties.
10. Locate and remove the snubber board cover using the 3/8" wrench. See Figure F.39.
11. Remove plug J30 from the snubber board.
See the Wiring Diagram. Clear leads for the
SCR/diode rectifier bridge assembly removal.
FIGURE F.39 – SNUBBER BOARD COVER REMOVAL
SNUBBER
BOARD
LOCATION
(LEFT SIDE,
BELOW
FUEL TANK)
COMMANDER 400
F-92
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
REMOVAL AND REPLACEMENT
(continued)
FIGURE F.40 – RESISTOR R1 LOCATION
F-92
RESISTOR R1
LEAD #204B
12. Using the 11/32" wrench, remove the #204B lead from the R1 (50 Ohm -100 Watt) resistor. See Figure F.40. Cut any necessary cable ties and clear leads for SCR/diode rectifier bridge assembly removal.
NOTE: Be sure to replace any cut cable ties on reassembly. Otherwise, the leads may catch in the blower.
13. Remove the capacitor leads and grommet from the rectifier bridge bracket. See Figure
F.41.
14. Using the 3/8" wrench, remove the four (2 on each side) screws from the rectifier bridge bracket. See Figure F.41.
FIGURE F.41 – RECTIFIER BRIDGE BRACKET DETAILS
GROMMET
BRACKET
COMMANDER 400
SCREWS (4)
F-93
TROUBLESHOOTING & REPAIR
SCR/DIODE RECTIFIER BRIDGE
REMOVAL AND REPLACEMENT
(continued)
FIGURE F.42 – SCR/DIODE RECTIFIER BRIDGE ASSEMBLY REMOVAL
F-93
RECTIFIER
15. Carefully lift and slide the SCR/diode rectifier bridge assembly out the left side of the machine. See Figure F.42.
REASSEMBLY
16. Carefully lift and slide the SCR/diode rectifier bridge assembly into the machine from the left side. See Figure F.42.
17. Using the 3/8" wrench, install the four (2 on each side) screws holding the SCR/diode rectifier bridge assembly rectifier bridge
18. Attach the capacitor leads and grommet to
the rectifier bridge bracket. See Figure F.41.
19. Using the 11/32" wrench, attach the #204B lead to the R1 (50 Ohm -100 Watt) resistor.
NOTE: Be sure to replace any cable ties cut during removal. Otherwise, the leads may catch in the blower.
20. Connect plug J30 to the snubber board.
Install the snubber board cover using the 3/8" wrench.
21. Using the 3/4" wrench, attach lead #207 to the negative "stick" output terminal. Replace any cable ties cut during removal.
22. Feed plug J6 and the toroid assembly into the control box. Connect plug J6 to the control board. Replace any cable ties cut during removal. Using the 5/16" nut driver, install the control board cover.
23. Using the 1/2" wrench, attach the shunt to the positive heat sink plate (lower). Attach the heavy #204C lead from the positive heat sink plate (lower). Attach lead #209 (small) and #209A (large) to the negative (upper) heat sink plate. Attach the stator weld winding leads to the SCR/diode rectifier bridge assembly. Replace any cable ties cut during removal.
24. Replace the front shroud and all case covers
that were removed. (See the Case Cover
Removal and Replacement Procedure.)
COMMANDER 400
F-94
NOTES
F-94
COMMANDER 400
F-95
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
The following procedure will aid the technician in removing the SCRs from the output rectifier heat sink for maintenance or replacement.
MATERIALS NEEDED
NO.000 Fine Steel Wool
Penetrox A-13 (Lincoln E2529) or Penetrox A
7/16” Open end wrench
Allen head type wrenches
F-95
This procedure takes approximately 50 minutes to perform.
COMMANDER 400
F-96
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.43 – SCR DETAILS
F-96
SPECIAL INSTRUCTIONS
NOTE: Before disassembling the existing rectifier, note toward which heat sink the outer metal ring of the power SCR is mounted. Also, note the positioning of the gate lead of the SCR. Failure to reinstall the new SCR in the same orientation as the original may result in subsequent damage to the new SCR and other components of the welder. See Figure F.43.
CAUTION
The unclamping and clamping procedure outlined below is critical for the prevention of internal SCR damage. Failure to follow this procedure may result in subsequent damage of the SCR. Handle all SCRs with care.
COMMANDER 400
F-97
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.44 – RECTIFIER BRIDGE ASSEMBLY BRACKET DETAILS
F-97
GROMMET
BRACKET
SCREWS (4)
PROCEDURE
1.
Turn the engine off.
2.
Perform the SCR/Diode Rectifier Bridge
3.
Using the 7/16” wrench, remove the mounting bracket for the SCR/diode rectifier bridge assembly bracket. See Figure F.44.
4.
Alternately loosen nuts 1/2 turn each until heat sinks are loose. Remove nuts and leaf spring. IT IS RECOMMENDED THAT NEW
HARDWARE, LEAF SPRING AND HOUS-
ING BE USED FOR REASSEMBLY.
5.
Remove the old SCR.
6.
Clean the area on the heat sink around the
SCR mounting surface, using a putty knife or similar tool. DO NOT SCRATCH THE SCR
MOUNTING SURFACE.
7.
Polish each heat sink’s mounting surface using NO. 000 fine steel wool. Wipe surface clean with a lint-free cloth or paper towel.
8.
Inspect the mounting surfaces of each new
SCR.
a.
Remove all burrs and wipe clean. Do not use steel wool or any abrasive cleanser on the SCR mounting surfaces.
9. Apply a thin (0.001” to 0.003”) layer of PEN-
ETROX A-13 (Lincoln Electric #E2529) or
PENETROX A, heat sink compound, to each heat sink’s SCR mounting surface.
a.
Care must be used to prevent foreign material contamination of the SCR to heat sink junction.
10. Place the new SCR between the heat sinks.
Be sure that the outer metal ring of the SCR is facing toward the same heat sink as the old
SCR’s metal ring. Be sure that the roll pin of the heat sink engages the “hole” in the SCR.
The SCR contact surfaces must sit flat against both heat sink surfaces.
COMMANDER 400
F-98
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.45 – 1/2” WIDE LEAF SPRING
F-98
11. Go to the procedure below that matches your machine’s cap screw. NOTE WHICH
THREAD IS ON YOUR CAP SCREWS
BEFORE PROCEEDING TO THE ASSEM-
BLY PROCEDURE. Two different designs of leaf springs and housings have been used to clamp the SCR to the rectifier. The two different designs can be identified by the size of the leaf spring. One design uses a 1/2 inch wide leaf spring, and the other uses a 5/8 inch wide spring. The different designs require different assembly and clamping procedures. The assembly procedure will be different depending upon the thread on the cap screws. A 1/4-28 thread requires a different tightening procedure than a 1/4-20 thread.
PROCEDURE FOR THE 1/2 INCH
WIDE SPRING
1.
Place a piece of sleeving around each cap screw.
2.
Insert cap screws through the leaf spring.
Orient the leaf spring so that its ends are curved upward toward the cap screw heads.
See Figure F.45. Pressing on the cap screw heads should produce a “rocking” motion of the spring in its housing. If the spring does
NOT rock, it is installed upside down.
Remove the spring and turn it over. Check for “rocking” motion. See Figure F.45.
3.
Insert cap screws and leaf spring into the plastic housing.
4.
Insert clamp assembly through heat sinks.
Install nuts. Tighten clamp nuts equally on cap screws until finger tight. (See Figure
F.46. Heat sinks may not be exactly as pictured.)
5.
Reinspect the SCR for proper seating.
FIGURE F.46 – CLAMP ASSEMBLY
COMMANDER 400
F-99 F-99
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
CLAMPING PROCEDURE
FOR 1/4-28 CAP SCREWS
NOTE: This procedure can only be used with 1/4-
28 cap screws.
Do not use cap screws with any other type thread or new SCR will be damaged.
Do not over tighten cap screws. The leaf spring will apply the required clamping force to the SCR.
1.
Do not turn the nuts. While holding the nuts stationary, turn the cap screws only with the following procedure.
2.
Tighten first cap screw 1/4 turn.
3.
Tighten second cap screw 1/2 turn.
4.
Tighten first cap screw 1/2 turn.
5.
Tighten second cap screw 1/2 turn.
6.
Tighten first cap screw 1/4 turn. STOP.
7.
Assembly now has the proper clamping force.
8.
CLAMPING PROCEDURE
FOR 1/4-20 CAP SCREWS
NOTE: This procedure can only be used with
1/4-20 cap screws.
Do not use cap screws with any other type thread or new SCR will be damaged.
Do not over tighten cap screws. The leaf spring will apply the required clamping force to the SCR.
1.
Do not turn the nuts. While holding the nuts stationary, turn the cap screws only with the following procedure.
2.
Tighten first cap screw 1/4 turn.
3.
Tighten second cap screw 1/2 turn.
4.
Tighten first cap screw 1/2 turn.
5.
Tighten second cap screw 1/2 turn.
6.
Tighten first cap screw 1/4 turn. STOP.
7.
Assembly now has the proper clamping force.
8.
COMMANDER 400
F-100
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.47 – HOUSING AND PRESSURE PAD FOR 5/8” WIDE LEAF SPRING
F-100
PROCEDURE FOR
THE 5/8 INCH WIDE SPRING
1. Place a piece of sleeving around each cap screw.
2. Insert cap screws through the leaf spring. The leaf spring is flat so the orientation of the leaf spring does not matter.
3. Place the steel pressure pad in the housing with the 1/8 inch wide standoff facing up. See
Figure F.47.
4. Insert cap screws and leaf spring into plastic housing being sure that the steel pressure pad remains in position. Pressing on the cap screw heads should produce a rocking action of the spring in its housing.
5. Insert the clamp assembly through the heat sinks. Install nuts. Tighten the clamp nuts equally on the cap screws until finger tight. Be sure that the leaf spring is not cocked in the housing. See Figure F.48. Heat sinks may not be exactly as pictured.
6. Reinspect the SCR for proper seating.
FIGURE F.48 – CLAMP ASSEMBLY
COMMANDER 400
F-101
TROUBLESHOOTING & REPAIR
SCR REMOVAL AND REPLACEMENT
(continued)
CLAMPING PROCEDURE
FOR 1/4-28 CAP SCREWS
NOTE: This procedure can only be used with
1/4-28 cap screws.
Do not use cap screws with any other type thread or new SCR will be damaged.
Do not over tighten cap screws. The leaf spring will apply the required clamping force to the SCR.
1. Do not turn the nuts. While holding the nuts stationary, turn the cap screws only with the following procedure.
2. Tighten first cap screw 1/4 turn.
3. Tighten second cap screw 1/2 turn.
4. Tighten first cap screw 1/2 turn.
5. Tighten second cap screw 1/2 turn.
6. Tighten first cap screw 1/2 turn.
7. Tighten second cap screw 1/4 turn. STOP.
8. Assembly now has the proper clamping force.
9. Perform the Active SCR Test.
CLAMPING PROCEDURE
FOR 1/4-20 CAP SCREWS
NOTE: This procedure can only be used with
1/4-20 cap screws.
Do not use cap screws with any other type thread or new SCR will be damaged.
Do not over tighten cap screws. The leaf spring will apply the required clamping force to the SCR.
1. Do not turn the nuts. While holding the nuts stationary, turn the cap screws only with the following procedure.
2. Tighten first cap screw 1/4 turn.
3. Tighten second cap screw 1/2 turn.
4. Tighten first cap screw 1/2 turn.
5. Tighten second cap screw 1/4 turn.
6. Tighten first cap screw 1/8 turn.
7. Tighten second cap screw 1/8 turn. STOP.
8. Assembly now has the proper clamping force.
9. Perform the Active SCR Test.
AFTER REPLACING THE SCRs
Follow the steps in the SCR/Diode Rectifier
Bridge Removal and Replacement procedure
to reassemble the machine.
F-101
COMMANDER 400
F-102
NOTES
F-102
COMMANDER 400
F-103
TROUBLESHOOTING & REPAIR
MOUNTING OF STUD TYPE DIODES TO ALUMINUM
HEAT SINKS
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
F-103
DESCRIPTION
The following procedure will aid the technician in mounting stud type diodes to the aluminum heat sinks on the Commander 400.
MATERIALS NEEDED
5/16” Nut driver
1/2” Open end wrench
Lincoln E1868 (Dow Corning 340) Heat Sink Compound
“Slip” type torque wrench
No. 000 fine steel wool
This procedure takes approximately 30 minutes to perform.
COMMANDER 400
F-104
TROUBLESHOOTING & REPAIR
MOUNTING OF STUD TYPE DIODES TO ALUMINUM
HEAT SINKS
(continued)
PROCEDURE
1.
Turn the engine off.
2.
Perform the SCR/Diode Bridge Removal
3.
Loosen the appropriate diode nut and remove the diode that is to be replaced.
4.
Clean the area on the heat sink around the diode mounting surface using a putty knife or similar tool. DO NOT SCRATCH THE DIODE
MOUNTING SURFACE.
5.
Polish each heat sink’s mounting surface using No. 000 fine steel wool. Wipe the surface clean with a lint-free cloth or paper towel.
6.
Inspect the mounting surfaces of each new diode. Remove all burrs and wipe clean. Do not use steel wool or any abrasive cleanser on the diode mounting surface.
7.
Apply a thin (0.003” to 0.007”) uniform layer of E1868 (Dow Corning 340) heat sink compound to the heat sink mounting surface.
a.
Do not apply compound to the diode stud or mounting threads.
b.
The diode threads must be clean and free of defects so that the nut can be finger tightened before applying torque. A
“slip” type torque wrench must be used to tighten the diode nut.
8. Tighten the diode nuts to the specifications in the following table.
a.
Start the nuts for diodes with steel studs by hand and then torque them according to the following table.
b.
Run the nuts for diodes with copper studs on all the way by hand then torque them according to Table F.4 below.
c.
Turn the nuts a minimum of 1/2 turn more while torquing.
DIODE STUD
SIZE
3/4-16
3/8-24
1/4-28
Table F.4
FOOT-
POUNDS
25-27
10±.5
INCH-
POUNDS
300-324
125+0/-5
22-25
9. Perform SCR/Diode Bridge Replacement
10. Install the case top and sides.
F-104
COMMANDER 400
F-105
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
F-105
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the engine and stator assembly. This is necessary in order to gain access the stator and/or rotor.
MATERIALS NEEDED
5/16" Nut driver
3/8" Wrench
1/2" Wrench
9/16" Socket Wrench
11/16" Socket Wrench
7/16" Wrench
3/4" Wrench
3/4" Socket Wrench
Slot head screw driver
Hoist (CHECK WEIGHT LIMITATIONS)
Pliers
5/8" Wrench
1/4" Allen type wrench
1-13/32" Socket wrench
This procedure takes approximately 8 hours to perform.
COMMANDER 400
F-106 F-106
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.49 – FUEL TANK REMOVAL DETAILS
FUEL RETURN LINE
FUEL LEVEL SENSOR
U-BOLT (2)
PREPARATION AND LEAD REMOVAL
PROCEDURE
1. Turn the engine off.
2. Using the 3/8" and 1/2" wrenches, remove the battery cover and disconnect the battery.
Remove the battery by sliding it out.
3. Perform the
(including removing the front shroud).
4. Using the 3/8" wrench, remove leads #242E and #229 from the fuel level sensor. See
Figure F.49. Label the leads for reassembly.
5. Turn the fuel off at the shutoff valve. Remove and plug the fuel return line. See Figure F.49.
6. Remove and plug the lower fuel line. See
Figure F.49.
7. Using the 9/16" socket wrench, remove the four nuts, washers and rubber washers from the fuel tank mounting U-bolts. See Figure
F.49.
8. Carefully remove the U-bolts and lift the fuel tank away from the machine.
COMMANDER 400
F-107 F-107
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.50 – REAR PANEL ASSEMBLY REMOVAL DETAILS
REAR
PANEL
ASSEMBLY
MOUNTING
SCREWS
(4)
BASE
9. Using the 3/8" wrench, remove the screws holding the rear panel assembly to the machine base. See Figure F.50.
10. Lift and remove the rear panel assembly.
11. Using the 9/16" wrench, remove the engine grounding strap. See Figure F.51.
FIGURE F.51 – GROUNDING STRAP REMOVAL
ENGINE GROUNDING
STRAP LOCATION
COMMANDER 400
F-108 F-108
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.52 – SHUTDOWN SOLENOID LEAD REMOVAL
PULL-IN COIL
(LARGER TERMINALS
EACH SIDE
#225 AND #262)
SHUTDOWN
SOLENOID
IDLER
SOLENOID
HOLD-IN COIL
(SMALLER TERMINALS
EACH SIDE
#224 AND #240)
12. Label and remove the four leads #224, #240,
#225 and #262 from the shutdown solenoid.
See Figure F.52. Cut any necessary cable ties.
13. Label and remove leads #226, #237, #227 and #254 from the idler solenoid. See Figure
F.53 Cut any necessary cable ties.
FIGURE F.53 – IDLER SOLENOID LEAD REMOVAL
SHUTDOWN
SOLENOID
PULL-IN COIL
(LARGER TERMINALS
TOP AND BOTTOM
#227 AND #254)
HOLD-IN COIL
(SMALLER
TERMINALS
TOP AND BOTTOM
#226 AND #237)
IDLER
SOLENOID
COMMANDER 400
F-109 F-109
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.54 – OIL PRESSURE SENSOR LEAD REMOVAL
OIL
PRESSURE
SENSOR
14. Label and remove leads #228 and #234 from the oil pressure sensor. See Figure
F.54.
15. Label and remove leads #233A and #241 from the oil temperature sensor. See Figure
F.55.
FIGURE F.55 – OIL TEMPERATURE SENSOR LEAD REMOVAL
OIL
TEMPERATURE
SENSOR
COMMANDER 400
F-110 F-110
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.56 – ENGINE GROUNDING LEAD
ENGINE GROUNDING
LEAD ATTACHMENT
POINT
16. Using the 11/16" socket wrench, remove the grounding lead from the top of the engine bell housing. See Figure F.56.
17. Cut any necessary cable ties to free the harness assembly from the engine/stator assembly.
18. Using the 11/16" wrench, remove leads
#236A, #236B and #236C from the starter motor solenoid.
19. Using the slot head screw driver, remove lead #231A and #231B from the starter motor solenoid.
20. Label and remove the #239 lead from the engine alternator using the 3/8" wrench.
21. Label and remove the #285 lead from the engine alternator using the 3/8" wrench.
22. Label and remove the #238 lead from the engine alternator using the 7/16" wrench.
23. Clear the wiring harness for engine/stator removal by cutting any necessary cable ties.
24. Using the 1/2" wrench, remove the three bundled leads (W1-W4, W2-W5 and W3-W6) from the SCR/diode rectifier bridge assembly.
COMMANDER 400
F-111 F-111
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.57 – EXCITER BOARD COVER REMOVAL
EXCITER
BOARD
COVER
MOUNTING
NUTS (3)
EXCITER
BOARD
BRASS
NUTS (3)
MOUNTING
SCREW
25. Using the 3/8" nut driver, remove the exciter board cover. This is sealed and may require some gentle prying to dislodge. See Figure
F.57.
WARNING
ELECTRIC SHOCK can kill.
• Do not operate with panels open.
• Disconnect NEGATIVE (-)
BATTERY LEAD before servicing.
• Do not touch electrically live parts.
26. Check for voltage at the three studs . If voltage is present, do not proceed. Call the
Lincoln Electric Service Dept. at 1-800-833-
9353.
With the 7/16" wrench, remove the three nuts and washers that mount the exciter board to the three studs. With the 1/4" nut driver, remove the lower mounting screw from the exciter board.
27. With the 7/16" wrench, remove the three brass nuts and label and remove the T1, T2 and T3 stator leads (only) from the studs. Cut any necessary cable ties. With the 5/16’ nut driver, remove the screws and drop the case front to access the control box. Remove the control board cover.
COMMANDER 400
F-112 F-112
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.58 – CONTROL BOARD PLUG J2 LOCATION
P e l 9 9 6
PLUG J2
28. Locate and remove plug J2 from the control board. See Figure F. 58. Thread plug J2 out of the control box.
29. Label leads 5 and 5A at the neutral T2 stud
(center stud) in the control box. Using the
7/16" wrench remove the leads. See Figure
F.59.
30. Using the 7/16" wrench remove lead #6 from the T1 stud (top stud) in the control box.
Label and remove the lead from the control box. Remove the #6 lead from the toroid assembly. See Figure F.59. Note the number of turns and the direction of the lead through the toroid hole. See the Wiring
Diagram. Cut any necessary cable ties.
31. Label the #3 lead from the T3 stud in the control box. Using the 7/16" wrench, remove the
#3 lead from the control box. Remove the #3 lead from the toroid assembly. See Figure
F.59. Note the number of turns and the direction of the lead through the toroid hole. See the Wiring Diagram. Clear the leads for stator removal.
FIGURE F.59 – CONTROL BOX STUD TERMINALS
T1 STUD
#6 LEADS
T2 STUD
#5 LEADS
T3 STUD
#3 LEADS
COMMANDER 400
F-113 F-113
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.60 – VERTICAL BAFFLE /ENGINE MOUNT REMOVAL
CV
CAPACITOR
AND SCR
ASSEMBLY
STATOR AND
ENGINE
MOUNTS
FUEL TANK
SUPPORT
RAIL
LIFT FRAME
ASSEMBLY
LIFT
FRAME
VERTICAL
BAFFLE
32. Using the 3/8" wrench, remove the eight screws that mount the lift frame vertical baffle to the lift frame assembly. See Figure
F. 60. Also remove the engine access door chain, noting its placement and length for reassembly.
33. Using the 1/2" wrench, remove the two screws holding the CV capacitor and SCR assembly to the fuel tank support rails. See
Figure F.60.
34. Move the CV capacitor and SCR assembly toward the front of the machine to allow clearance for the engine/stator removal.
35. Using the 1/2" wrench and 5/16" nut driver, remove the tank/fan guard. See Figure F.60..
36. Using the 3/4" wrench and socket wrench, remove the four engine and stator mounting nuts, spacers, rubber mounts and bolts. See
Figure F.60.
37. Using the hoist, carefully lift and remove the engine/stator assembly, being careful to balance the unit. Be sure to remove the lead bundles W1 through W6 from the lower left side fan shroud. Set the engine/stator assembly on secure blocks for support and for the stator removal procedure. Be sure the engine/stator assembly is secure on the blocks.
COMMANDER 400
F-114 F-114
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.61 – STATOR REMOVAL
Stator/Engine
Mounting Bolts and Lockwashers
Cap Screws (4)
Bottom Flywheel
Cover
Fan Hub
Fan Nut
STATOR REMOVAL PROCEDURE
1. Using the 1/4" Allen wrench, remove the four cap screws mounting the fan blade to the hub.
2. Using the 1-13/32" socket wrench, remove the fan nut from the threaded shaft. Remove the fan blade, taking note of placement for reassembly. (Be sure not to place the fan on backwards.)
3. Using the 7/16" wrench, remove the three bolts and lock washers holding the bottom flywheel cover to the stator frame assembly.
Remove the cover. See Figure F. 61.
4. Using the 11/16" wrench, remove the eight bolts and lock washers holding the stator frame to the engine. Support the stator with the hoist and make sure the engine is blocked securely. See Figure F.61.
5. Remove the stator from the engine/rotor assembly by prying and sliding the stator from the engine.
COMMANDER 400
F-115 F-115
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
FIGURE F.62 – BLOWER PADDLE/FLEX PLATE REMOVAL
ROTOR FLEX
PLATE
ROTOR
BLOWER PADDLE
ROTOR REMOVAL PROCEDURE
1. Using the 5/8" wrench, remove the blower paddles/rotor flex plate bolts and lock washers. See Figure F. 62. Support the rotor and engine securely.
WARNING
The rotor will be free to fall when the bolts are removed.
2. Using the hoist, carefully remove the rotor and flex plate assembly.
REASSEMBLY NOTES
Reassemble the rotor and stator to the
Commander 400 by carefully retracing the disassembly procedure steps in reverse order. Keep the following special points in mind as you proceed. Lead Reconnection Checklists are provided here as an aid to reassembly.
1.
INSTALL ROTOR: Support the rotor with the hoist. Install the blower paddles and flex plate to the engine flyweel.
2.
INSTALL STATOR: Be sure the engine is blocked securely and the stator is supported with the hoist. Install the stator to the engine with the eight bolts and lock washers. Install the bottom flywheel cover to the stator frame with three bolts and lock washers. Install the fan blade, making sure that it faces the proper direction, with the fan nut and four Allen head cap screws.
Check the air gap for .012” minimum.
COMMANDER 400
F-116 F-116
TROUBLESHOOTING & REPAIR
ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT
(continued)
LEAD RECONNECTION CHECKLIST
Engine
❒ Engine grounding strap to engine
❒ Leads #242E and #229 to fuel level sensor
❒ Leads #224, #240, #225, and #262 to shutdown solenoid
❒ Leads #226, #237, #227, and #254 to the idler solenoid
❒ Leads #228 and #234 to oil pressure sensor
❒ Leads #233A and #241 to oil temperature sensor
❒ Grounding lead to top of engine bell housing
❒ Leads #236A, #236B, #236C, #231A and
#231B to starter motor solenoid
❒ Leads #239, #285, and #238 to engine alternator
SCR/Diode rectifier bridge assembly
❒ Stator leads W1-W4, W2-W5 and W3-W6.
Exciter board
❒ Stator leads T1, T2, and T3 to studs
Control board/box
❒ Plug J2
❒ Leads #5 and #5A to neutral T2 stud (center)
❒ Lead #6 to T1 stud (top) and toroid assembly
(note number of turns and direction)
❒ Lead #3 to T3 stud (bottom) and toroid assembly (note number of turns and direction)
COMMANDER 400
F-117 F-117
TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Mode
Low Idle
High Idle
No Load RPM
1325 - 1400
1890 - 1915
Load RPM
NA
1800
Range Switch
Maximum
WELDER DC (STICK) OUTPUT
Fine Control
Maximum
Open Circuit
Volts
70
Load Volts
40
Load Amps
500
Range Switch
Maximum
WELDER CV (WIRE) OUTPUT
Fine Control
Maximum
Open Circuit
Volts
48
Load Volts
40
Load Amps
500
Open Circuit
Voltage
230 - 250
230 Volt Receptacle
Load Volts Load Amps
224
AUXILIARY POWER OUTPUT
44.6
Open Circuit
Voltage
115 - 132
115 Volt Receptacle
Load Volts
108 - 126
Load Amps
13 - 16
COMMANDER 400
F-118
NOTES
F-118
COMMANDER 400
G-1
ELECTRICAL DIAGRAMS
TABLE OF CONTENTS
ELECTRICAL DIAGRAMS SECTION
Electrical Diagrams Section ..........................................................................................Section G
G-1
COMMANDER 400
WIRING DIAGRAM - STICK MODEL (CODE 9978)
3 D
1002 1004
S T U D T 1 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
5 D
1006 1008
T1
270
269
268
274
5D
272
273 240A
3 D
1 2 3 4 5 6 7 8 9 1 0
G 1 G 2 G 3 2 0 4 A
R E C T I F I E R
A S S E M B LY 2 0 4 S 2 0 6 S 2 0 7
2 0 6
N OT E :
N O C O N N E C T I O N
O N N E W E R M O D E L S.
C O N N E C TO R C AV I T Y N U M B E R I N G S E QU E N C E
( V I E W E D F RO M C O M P O N E N T S I D E O F B OA R D )
N E X T AV L B.
2 8 7
2 4 0 u F
1009
1011
1013
1015
1010
1012
1014
1016
S T U D T 2 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
T 2
J 5 0
CONNECTIONS TO
CAPACITORS MADE
VIA EYELET BOLTED
CONNECTIONS
S TATO R
EXCITER VOLTAGE
FEEDBACK BOARD
W 6
W 5
W 2
W 3
W 6
W 4
W 3
W 1
DA
S C R A
D B
S C R B
D C
S C R C
D D
204B
209
50 Ohm
100 W
6 0 0 A M P
S H U N T
O U T P U T
C H O K E
STAINLESS STEEL
STAND-OFF
FRAME GROUND
P O S.
B Y PA S S P C
B OA R D
E L E C T R I C A L S Y M B O L S P E R E 1 5 3 7
NOTE: ONLY ON
SOME OLDER
MODELS
CC
N E G .
3 D
5 H
5 D
2 4 0 u F
1017
1019
1021
1023
1018
S T U D T 3 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
1020
1022
1024
T 3
T 3
E X C I T E R
W I N D I N G S
W 5
W 2 W 1
W 4
W 6
STAINLESS STEEL
STAND-OFF
FRAME GROUND
AUXILIARY BYPASS PCB
B 4
260
B 5 B 6
261
B 7
223 204
77C
REMOTE/
LOCAL
SWITCH
S1
77 76
76C
SELECTOR SWITCH
(VIEWED FROM BACK)
(SEE SELECT SWITCH CHART)
S8
76B
75
FINE CONTROL
POT
C W
VIEWED FROM
BACK
77B
C O N T RO L H A R N E S S
217
218
219
220
221
8
7
6
9
5
4
A
222
1
3
2
216
215
214
213
2
4 75
75B
270
269
268
279
274
272
273
280
206S
204S
1 2 3 4 1 2 3 4 5 6
G1
G2
G3
204A
206
J 3 0 J 3 1
S N U B B E R P C B OA R D
207
5 D
5 E
N E U T R A L T 2 S T U D
I N C O N T RO L B OX
GND-D
GFCI
5 G
76
77
256
255
5 A
W H I T E
11
2 4 0 u F
5 G
GND-C
5
1001
1003
1005
1007
1002
1004
1006
1008
8
GND-E
120 V
L I N E H OT L OA D H OT
J 1 2
8 A
GFCI
5 E
WHITE
TERM.
5 H
W H I T E
L I N E
L I N E
W H I T E
J 1 0
120/240V
12
3
L OA D
W H I T E
L OA D
W H I T E
9
3 D
T 1
5 J
9
120 V
L I N E H OT L OA D H OT
J 1 1
9 A
5 K
12
E 2
CB1
50A
6
5
5 A
CB2
50A
8 A
5 J
9 A
5 K
CB4
15A
CB3
15A
3
GND-C
GND-D
GND-E
AU X . P OW E R
G RO U N D S C R E W
O N C O N T RO L PA N E L
242I
GND-A
11
8
5C
GND-F
W E L D E D S T U D
O N O U T P U T PA N E L
6A
3B
3A
5C
E 1
6
3
T 2
T 3
I N S U L AT E D S T U D
I N C O N T RO L B OX
3
280
3D
6B
T 1 I N S U L AT E D S T U D
I N C O N T RO L B OX
8 A
5 J
9 A
5 K
279
AUX. CURRENT
SENSE TOROID
8 A
5 J
9 A
5 K
6
238
4B
2B
75B
77C
76C
1
2
3
4
5
J 6 1
6
7
S TA I N L E S S S T E E L
S TA N D - O F F
8
REMOTE PROTECTION PCB
A M M E T E R
243
-
236C
A LT.
5C
9 A
224
225
5 K
H O U R M E T E R
239B
5 J
239A
-
8 A
F R A M E G RO U N D
HOLD
COIL
SHUTDOWN SOLENOID
PULL
COIL
2D
75D
76D
4D
77D
N OT E :
N O C O N N E C T I O N
O N N E W E R M O D E L S.
240
262
S O L E N O I D G RO U N D
S T U D O N E N G I N E
242G
2B
OUTPUT
CONTROL
SOURCE
S6
4B
ALWAYS ON
OUTPUT REMOTELY
CONTROLLED
C O N T RO L H A R N E S S
226
227
77D
76D
75D
242I
4D
2D
E N G I N E TO P C B H A R N E S S
HOLD
COIL
IDLE SOLENOID
PULL
COIL
PA N E L TO P C B H A R N E S S
2
4
A
B
C
REMOTE
CONTROL
D
E
TRIGGER
F GROUND
AMPHENOL 2
237
254
IDLER
SWITCH
S4
232F
O I L
P R E S S.
S
-
228A
232G
242C
247
L OW
P R E S S.
SILVER
TAB
CONTROL PANEL
GROUND SCREW
232B
232A
T E M P.
S
-
241A
242A
242B
242D
232D
246
T E M P.
232C
229A
229B
F U E L
S
-
242G
232E
245
L OW
F U E L
E N G I N E H A R N E S S TO PA N E L W I R E S
SILVER
TAB
242
SILVER
TAB
256
255
217
218
219
220
221
222
213
214
215
216
E2
E1
HIGH
AUTO
PA N E L TO PA N E L W I R E S
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2
228A
241A
242D
229A
239B
J 1 6
1
2
3
4
5
8
9
6
7
P 1 6
1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 6 7 8 9 1 0
3
4
1
2
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
4
1
232A
232H
267
J 8
J 7
M OT H E R
C O N T RO L
P C B OA R D
J 3
1 2 3 4 5 6
J 4
J 1
CONNECTIONS ON CONTROL BOARD
(VIEWED AS INSTALLED)
ENGINE
PROT.
BOARD
J 2 3
J 2 J 6 J5 J8 J7 J 1 J 4 J3
B 1 B 2 B 3
B 1 B 2 B 3
E N G I N E P ROT.
B OA R D J 2 3
J 6
J 5
S P I
S C I
8
1 5
1 6
3
4
6
1
2
STAINLESS STEEL
STAND-OFF
C O M M O N B AT T.
1 3 4 5 6 7 8
250
251
252
253
4 3 2 1
J 4 0
M E T E R
P C B
( o p t i o n a l )
J 2
232
RUN
STOP
236A
285
224
226
237
234
S3
228
286
B O LT O N TO
S E N D E R B R K ’ T
O I L P R E S S U R E S W I T C H
& S E N S O R
S E N S O R
G
SWITCH
W K
234
241
242E
229
O I L T E M P. S E N S O R & S W I T C H
S E N S O R
S W I T C H
F U E L LV L .
S E N S O R
233A
227
262
232
233
233A
240
239A
245
247
233
229B
243
246
START BUTTON
S2
231A 236B
236A
236C
285
LARGE
TAB
231A
S TA RT E R
S O L E N O I D
231B
STARTING
MOTOR D2
3A
A LT E R N ATO R
S E N S E
E X C
P O S
N E G
281
FRAME GROUND
240 240A
SELECTOR SWITCH (S8)
POSITION NAMEPLATE SETTING
1 NO FUNCTION
2 NO FUNCTION
3 90 MAX
4 120 MAX
5 180 MAX
6 230 MAX
7 270 MAX
8 400 MAX
9 50-575
(+)
(-)
12 VOLT
BATTERY
NOTE: DIODE APPEARS
ON SOME MODELS
BUT REPLACED BY
LEAD 285 ON NEWER
MODELS.
S T U D O N E N G I N E
M O U N T C H A N N E L
SMALL
TAB
239
239
E N G I N E H A R N E S S
238
S T U D O N
E N G I N E
GND-H
242
GND-F
5C
STUD ON GENERATOR
MOUNT CHANNEL
E N G I N E G RO U N D
1-16-98E
L9041
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
COMMANDER 400
G-3
WIRING DIAGRAM - STICK & WIRE MODEL (CODE 9979)
ELECTRICAL DIAGRAMS
3 D
1002
S T U D T 1 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
1004 1006
5 D
1008
T1
2 4 0 u F
1009
1011
1013
1015
1010
1012
1014
1016
S T U D T 2 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
T 2
270
269
268
274
5 D
272
273 240A
3 D
1 2 3 4 5 6 7 8 9 1 0
J 5 0
CONNECTIONS TO
CAPACITORS MADE
VIA EYELET BOLTED
CONNECTIONS
EXCITER VOLTAGE
FEEDBACK BOARD
S TATO R
6
6
3
3
W 2
W 5
W 4
W 1
W 6
W 3
W 3
W 6
DA
G 1
SCR A
G 2
SCR B
G 3
SCR C
DD
2 0 4 A
RECTIFIER
ASSEMBLY
2 7 7
204C
204B
SCR 1
G 4
2 0 4 S 2 0 6 S
DE
30,000 uF
6 0 0 A M P
S H U N T
285 285A
DB DC
223 204
209
C1-C4
284A 284 284B
2 0 8
3
6
280
279
6
3
2 0 7
2 0 6
N OT E :
N O C O N N E C T I O N
O N N E W E R M O D E L S
P O S.
2 0 6 A
C U R R E N T
S E N S E TO RO I D
B Y PA S S P C
B OA R D
L1
OUTPUT
CHOKE
F R A M E
G RO U N D
CC
CV
N E G .
2 0 8 A
2
4 75
75B
CONNECTOR CAVITY NUMBERING SEQUENCE
(VIEWED FROM COMPONENT SIDE OF BOARD)
NEXT AVAILABLE 287
ELECTRODE
POLARITY
SWITCH
S5
2 0 6 A
NEG.
POS.
2 0 8 A
ELECTRICAL SYMBOLS PER E1537
21
1017
1019
1021
1023
3 D
2 4 0 u F
5 D
1018
S T U D T 3 O N
C A PAC I TO R
C O N N E C T I O N B L O C K
1020
1022
1024
T 3
1001
1003
1005
1007
T 1
T 3
E X C I T E R
W I N D I N G S
T 2
3 6 3 6
W 2
W 5
W 1
2B
OUTPUT
CONTROL
SOURCE
S6
4B
W 4
2
ALWAYS ON
OUTPUT REMOTELY
CONTROLLED
4
VOLT/AMP
SWITCH
S9
260
V
282
283
A
261
21
209A
77C
REMOTE/
LOCAL
SWITCH
S1
CV CHOKE
L2
77 76
76C FINE CONTROL
POT
CW
76B
75 VIEWED FROM
BACK
77B
217
218
219
220
221
7
8
9
6
222
SELECTOR
SWITCH
5
(VIEWED
216
S8
FROM BACK)
SEE CHART
4
215
3
A
2
214
1
213
76
77
256
255
270
269
268
279
274
272
273
280
NOTE: ONLY ON
SOME OLDER
MODELS
1 2 3 4 1 2 3 4
J 3 0 J 3 1
S N U B B E R P C B OA R D
206S
204S
G1
G2
G3
204A
206
207
2 4 0 u F
5 A
5 D
5 E
N E U T R A L T 2 S T U D
I N C O N T RO L B OX
5
3 1
5 H
5 G
8A
W H I T E
8
GND-E
115 V
L I N E H OT L OA D H OT
J 1 2
GND-D
GFCI
5 G
9A
L I N E
W H I T E
5J
L OA D
W H I T E
9
115 V
L I N E H OT L OA D H OT
J 1 1
GFCI
L I N E
W H I T E
L OA D
W H I T E
5 E
5K
E 2
5 H
6
5
5 A
3
12
GND-C
1002
1004
1006
1008
J 1 0
115/230V
WHITE
TERM.
5 H
11
STAINLESS STEEL
STAND-OFF
B4
AUXILIARY BYPASS PCB
B5 B6
FRAME
GROUND
9A 5K 5J
3 D
B7
8A
CB1
50A
12
GND-C
GND-D
GND-E
AU X . P OW E R
G RO U N D S C R E W
I N C O N T RO L B OX
2 4 2 I
2 4 2 H
GND-A
GND-F
W E L D E D S T U D
O N O U T P U T PA N E L
8
9
5C
CB4
15A
3B
T 3
I N S U L AT E D S T U D
I N C O N T RO L B OX
3
32
6
CB3
15A
3A
3D
CB2
50A
11
6A
5C
E 1
CB5 15AMP
6B
T 1 I N S U L AT E D S T U D
I N C O N T RO L B OX
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 6 7 8 9 1 0
3 6
32A
1 1 5 AC
C O N TAC TO R
WO R K
R E M OT E
C O N T RO L
K
B
G RO U N D
A M P H E N O L 1
F
G
H
E
I
D
C
J
A
A
R E M OT E
C O N T RO L
B
C O N TAC TO R
G RO U N D
A M P H E N O L 2
E
F
C
D
2 4 2 I
2 1
7 7 E
7 6 E
7 5 E
3 1
3 2 A
4 E
2 E
2 4 2 H
7 7 D
7 6 D
7 5 D
4 D
2 D
2 4 2 I
2 4 2 H
21
224
225
SHUTDOWN
HOLD
COIL
SOLENOID
PULL
COIL
7 7 C
7 5 B
7 6 C
2 B
4 B
7 7 E
4 E
7 5 E
7 6 E
2 E
R F B Y PA S S
P C B OA R D
4
8
3
7
5
1
6
2
J 6 1
3
2
1
5
6
4
J 6 2
7 5 D
7 7 D
2 D
7 6 D
4 D
1
5
2
6
3
4
J 6 0
240 226
262
S O L E N O I D G RO U N D
S T U D O N E N G I N E
227
FRAME GROUND
E N G I N E TO P C B H A R N E S S
IDLE
HOLD
COIL
SOLENOID
PULL
COIL
237
254
277
283
208
G4
282
J 2 1
1
CV DAUGHTER BOARD
IDLER
SWITCH
S4
256
HIGH
AUTO
J 2 0
1
232A
238
A M M E T E R
5C
243
-
236C
A LT.
H O U R M E T E R
239B
-
242G
239A
PA N E L TO P C B H A R N E S S
232B
232F
O I L
P R E S S.
S
-
228A
232G
242C
247
L OW
P R E S S.
T E M P.
S
-
241A
232A
242A
242B
242D
INSTRUMENT PANEL
GROUND SCREW
IN CONTROL BOX
232C
232D
246
T E M P.
229A
229B
F U E L
S
-
242G
232E
245
L OW
F U E L
E N G I N E TO PA N E L H A R N E S S
242
PA N E L TO PA N E L W I R E S
255
228A
241A
242D
229A
239B
J 1 6
3
4
5
6
1
2
7
8
9
P 1 6
E2
E1
232H
267
213
214
215
216
217
218
219
220
221
222
232
RUN
STOP
236A
8
9
1 0
1 1
1 2
1 3
1 4
5
6
7
1
2
3
4
4
1
S3
J 2
M OT H E R
C O N T RO L
P C B OA R D
J 7
J 8
J 3
1 2 3 4 5 6
285
224
226
237
234
233
B O LT O N
S E N D E R
B R AC K E T
286
228
241
O I L P R E S S U R E S W I T C H & S E N S O R
G
S E N S O R
SWITCH
W K
234
O I L T E M P. S E N S O R & S W I T C H
S E N S O R
233A
S W I T C H
242E
229
F U E L LV L .
S E N S O R
E N G I N E TO PA N E L H A R N E S S
239
233A
236A
236C
285
B 1 B 2 B 3
239
227
262
232
START BUTTON
S2
231A 236B
STARTING
MOTOR
J 2 1
J 2 J 6 J 5 J 8 J 7 J 1 J 4 J 3
J 1
J 4
CONNECTIONS ON CONTROL BOARD
(VIEWED AS INSTALLED)
CV
BOARD
ENGINE
PROT.
BOARD
J 2 3
B 1 B 2 B 3
E N G I N E P ROT.
B OA R D J 2 3
J 5
S P I
4
1
5
3
2
6
S C I
7
8
STAINLESS STEEL
STAND-OFF
C O M M O N B AT T.
1 3 4 5 6 7 8
SENSE
POS
EXC
NEG
A LT E R N ATO R
281
238
239A
245
247
233
229B
243
246
231A
S TA RT E R
S O L E N O I D
240
231B
GND-H
D2
3A
242
GND-F 5C
STUD ON GENERATOR
MOUNT CHANNEL
J 6
253
252
251
250
J 4 0
M E T E R
P C B
FRAME GROUND
240
SELECTOR SWITCH (S8)
POSITION NAMEPLATE SETTING
1 NO FUNCTION
2 WIRE WELDING CV
3 90 MAX.
4 120 MAX.
5 180 MAX.
6 230 MAX.
7 270 MAX.
8 400 MAX.
9 50-575
NOTE: DIODE APPEARS ON
SOME MODELS BUT
REPLACED BY LEAD
285 ON NEWER MODELS.
(+)
12 VOLT
BATTERY
(-) S T U D O N E N G I N E
M O U N T C H A N N E L
S T U D O N
E N G I N E
E N G I N E G RO U N D
1 2 3 4
240A
1-16-98E
L8910
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
G-3
COMMANDER 400
G-4
WIRING DIAGRAM - STICK MODEL (CODE 10580)
ELECTRICAL DIAGRAMS
CAPACITOR
3D
5D
1002 1004 1006 1008
T1
270
269
268
274
5D
272
273 240A
3D
1 2 3 4 5 6 7 8 9 10
G1 G2 G3 204A
RECTIFIER
ASSEMBLY 204S 206S 207
1
CONNECTOR CAVITY NUMBERING SEQUENCE
(VIEWED FROM COMPONENT SIDE OF BOARD)
3 1 5 1 6
NEXT AVLB.
287
1009
1011
1013
1015
J50
CONNECTIONS TO
CAPACITORS MADE
VIA BOLTED
CONNECTIONS
STATOR
EXCITER VOLTAGE
FEEDBACK BOARD
W4
W3
POS.
CC
NEG.
J3
4
,J31,J60
6
1 7
6
1
J6 ,J50
10 7
8
J8
12
1 2
240 uF
1010
1012
1014
1016
W5
W2
W6
SCR A SCR B SCR C
DD
204B
50 Ohm
100 W
600 AMP
SHUNT
STAINLESS STEEL
STAND-OFF
FRAME GROUND
BYPASS PC
BOARD
8
1
J7
14
9
J5
4
ELECTRICAL SYMBOLS PER E1537
16 3
J1,J2
4
,J30
OUTPUT
CHOKE
W6 W3
W1
DA DB DC 209
T2 5
J4 ,J23 ,J61
8
3D
5H
5D
240 uF
5D
5E
NEUTRAL T2 STUD
IN CONTROL BOX
1017
1019
1021
1023
1018
1020
1022
1024
T3
T3
EXCITER
WINDINGS
W5
W2 W1
W4
W6
STAINLESS STEEL
STAND-OFF
FRAME GROUND
260
AUXILIARY BYPASS PCB
B4 B5 B6
261
B7
223 204
77C
REMOTE/
LOCAL
SWITCH
S1
77 76
76C
SELECTOR SWITCH
(VIEWED FROM BACK)
(SEE SELECT SWITCH CHART)
S8
76B
75
FINE CONTROL
POT
CW
VIEWED FROM
BACK
77B
CONTROL HARNESS
217
218
219
220
221
6
5
4
8
7
9
222
A
1
2
3
216
215
214
213
2
4 75
75B 76
77
256
255
TOROID
270
269
268
279
274
272
273
280
TOROID
206S
204S
1 2 3 4
G1
G2
G3
204A
206
J30
SNUBBER PC BOARD
207
WHITE
11
240 uF
5A
5G
GND-C
5
1001
1003
1005
1007
1002
1004
1006
1008
GND-E
120 V
LINE HOT
8
LOAD HOT
J12
8A
GND-D
GFCI
5G
WHITE
LINE
LOAD
WHITE
5J
9
120 V
LINE HOT LOAD HOT
J11
9A
GFCI
LINE
WHITE
LOAD
WHITE
5E
J10
120/240V
WHITE
TERM.
5H
12
3
9
3D
T1
5K
12
E2
CB1
50A
6
5
5A
GND-C
GND-D
GND-E
AUX. POWER
GROUND SCREW
ON CONTROL PANEL
242I
GND-A
11
8
5C
GND-F
WELDED STUD
ON OUTPUT PANEL
8A
5J
9A
5K
CB2
50A
6A
3
5C
E1
6
3
T2
280
CB4
15A
3B
CB3
15A
3A
T3
INSULATED STUD
IN CONTROL BOX
3
3D
6B
T1 INSULATED STUD
IN CONTROL BOX
8A
5J
9A
5K
9A
5K
5J
8A
4B
2B
75B
77C
76C
1
2
3
4
5
J61
6
7
8
STAINLESS STEEL
STAND-OFF
REMOTE PROTECTION PCB
FRAME GROUND
2D
75D
76D
4D
77D
2B
OUTPUT
CONTROL
SOURCE
S6
4B
ALWAYS ON
OUTPUT REMOTELY
CONTROLLED
CONTROL HARNESS
4
2
TOROID
77D
76D
75D
4D
2D
242I
A
B
REMOTE
CONTROL
C
D
E
TRIGGER
F GROUND
AMPHENOL 2
217
218
219
220
221
222
213
214
215
216
E2
E1
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8
7
8
9
10
11
12
13
14
1
2
3
4
5
6
4
1
J2
J8
J7
MOTHER
CONTROL
PC BOARD
J3
1 2 3 4 5 6
285
224
226
237
234
B1
J4
J1
CONNECTIONS ON CONTROL BOARD
(VIEWED AS INSTALLED)
ENGINE
PROT.
BOARD
J23
J2 J6 J5J8 J7 J1 J4 J3
B2 B3
B1 B2 B3
ENGINE PROT.
BOARD J23
J6
J5
SPI
1
2
3
4
6
SCI
8
15
16
STAINLESS STEEL
STAND-OFF
COMMON BATT.
1 3 4 5 6 7 8
227
262
232
1 2 3 4 1 2 3 4 6 7 8 9 10
239A
245
247
233
229B
243
246
250
251
252
253
4 3 2 1
J40
METER
PCB
(optional)
ENGINE TO PCB HARNESS
279
AUX. CURRENT
SENSE TOROID
8A
5J
9A
5K
6
224
225
HOLD
COIL
SHUTDOWN SOLENOID
PULL
COIL
240
262
226
227
HOLD
COIL
IDLE SOLENOID
PULL
COIL
237
254
IDLER
SWITCH
S4
256
255
HIGH
AUTO
238
AMMETER
5C
243
-
236C
ALT.
HOUR METER
239B
239A
-
SOLENOID GROUND
STUD ON ENGINE
242G
PANEL TO PCB HARNESS
PANEL TO PANEL WIRES
232F
OIL
PRESS.
S
-
228A
SILVER
TAB
232B
247
232G
242C
LOW
PRESS.
TEMP.
S
-
241A
232A
242A
242B
242D
CONTROL PANEL
GROUND SCREW
242
232D
246
TEMP.
232C
229A
229B
FUEL
S
-
242G
232E
245
LOW
FUEL
SILVER
TAB
ENGINE HARNESS TO PANEL WIRES
SILVER
TAB 228A
241A
242D
229A
239B
J16
3
4
5
1
2
6
7
8
9
P16
232A
232H
232
RUN
STOP
267
236A
286
BOLT ONTO
SENDER BRK'T
228
241
OIL PRESSURE SWITCH
& SENSOR
SENSOR
G
SWITCH
WK
OIL TEMP. SENSOR & SWITCH
234
SENSOR
233A
SWITCH
242E
229
FUEL LVL.
SENSOR
239
S3
ENGINE HARNESS
233
233A
240
236A
236C
285
LARGE
TAB
SMALL
TAB
239
START BUTTON
S2
231A 236B
STARTING
MOTOR
SENSE
POS
EXC
NEG
ALTERNATOR
238
231A
STARTER
SOLENOID
GND-H
242
FRAME GROUND
240 240A
SELECTOR SWITCH (S8)
POSITION NAMEPLATE SETTING
1 NO FUNCTION
2 NO FUNCTION
3 90 MAX
4 120 MAX
5 180 MAX
6 230 MAX
7 270 MAX
8 400 MAX
9 50-575
(+)
12 VOLT
BATTERY
(-)
STUD ON ENGINE
MOUNT CHANNEL
STUD ON
ENGINE
GND-F
5C
STUD ON GENERATOR
MOUNT CHANNEL
ENGINE GROUND
5-15-98A
L11008
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
G-4
COMMANDER 400
G-5
WIRING DIAGRAM - STICK & WIRE MODEL (CODE 10581)
ELECTRICAL DIAGRAMS
240 uF
3D
1002 1004 1006
5D
1008
T1
1009
1011
1013
1015
1010
1012
1014
1016
T2
270
269
268
274
5D
272
273 240A
3D
1 2 3 4 5 6 7 8 9 10
J50
CONNECTIONS TO
CAPACITORS MADE
VIA BOLTED
CONNECTIONS
STATOR
EXCITER VOLTAGE
FEEDBACK BOARD
6
6
3
3
W2
W5
W4
W1
DA
G1
SCR A
G2
SCR B
G3
SCR C
DD
204A
RECTIFIER
ASSEMBLY
277
204C
204B
SCR 1
G4
204S 206S
DE
30,000 uF
600 AMP
SHUNT
285 285A
260
DB
261
DC
223 204
209
C1-C4
209A
CV
L2
CHOKE 284A 284 284B
208
3
6
280
279
6
3
207
206
NOTE:
NO CONNECTION
ON NEWER MODELS
POS.
206A
CURRENT
SENSE TOROID
BYPASS PC
BOARD
L1
OUTPUT
CHOKE
FRAME
GROUND
CC
CV
NEG.
208A
1 2
CONNECTOR CAVITY NUMBERING SEQUENCE
(VIEWED FROM COMPONENT SIDE OF BOARD)
NEXT AVAILABLE 287
1 3 1 4 1
1
3
J1,J2
4 4
J3
6 1
6 5
J4 ,J23
7
8
1
5
6
J6,J20
10
8
16 7
J8
12 8
ELECTRODE
POLARITY
SWITCH
S5
206A
NEG.
POS.
14 9
J7
J5
ELECTRICAL SYMBOLS PER E1537
21
208A
1017
1019
1021
1023 T3
W1 W4
W3
W6
3D
5D
240 uF
1018
1020
1022
1024
T3
1001
1003
1005
1007
T1
EXCITER
WINDINGS
T2
3 6 3 6
W2
W5
2B
OUTPUT
CONTROL
SOURCE
S6
4B
W6
W3
2
ALWAYS ON
OUTPUT REMOTELY
CONTROLLED
4
VOLT/AMP
SWITCH
S9
A
V
282
283
21
77C
REMOTE/
LOCAL
SWITCH
S1
77 76
76C
76B 75
FINE CONTROL
POT
CW
VIEWED FROM
BACK
77B
217
218
219
220
221
8
7
9
6
222
SELECTOR
SWITCH
5
4
216
S8
(VIEWED
FROM BACK)
SEE CHART
3
215
A
2
214
1
213
2
4 75
75B 76
77
256
255
270
269
268
279
274
272
273
280
1 2 3 4
J30
206S
204S
G1
G2
G3
204A
206
207
5A
5D
5E
NEUTRAL T2 STUD
IN CONTROL BOX
5
31
5H
5G
8A
8
WHITE
GND-E
115 V
LINE HOT LOAD HOT
J12
GND-D
GFCI
5G
9A
LINE
WHITE
5J
LOAD
WHITE
9
115 V
LINE HOT LOAD HOT
J11
GFCI
LINE
WHITE
LOAD
WHITE
5E
5K
E2
5H
GND-C
J10
115/230V
12
240 uF
1002
1004
1006
1008
11
WHITE
TERM.
5H
STAINLESS STEEL
STAND-OFF
B4
AUXILIARY BYPASS PCB
B5 B6
FRAME
GROUND
9A 5K 5J
3D
B7
8A
CB1
50A
12
6
5
5A
3
5C
CB2
50A
11
6A
E1
GND-C
GND-D
GND-E
AUX. POWER
GROUND SCREW
IN CONTROL BOX
242I
242H
GND-A
GND-F
WELDED STUD
ON OUTPUT PANEL
8
9
5C
CB5 15AMP
CB4
15A
3B
CB3
15A
3A
T3
INSULATED STUD
IN CONTROL BOX
3
3D
32
6
6B
T1 INSULATED STUD
IN CONTROL BOX
1 2 3 4
5 6
7 8 9 10 11 12 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 6 7 8 9 10
3 6
32A
115AC
CONTACTOR
WORK
REMOTE
CONTROL
F
G
H
E
K
I
B
GROUND
AMPHENOL 1
J
A
D
C
A
REMOTE
CONTROL
B
C
D
CONTACTOR
GROUND
E
F
AMPHENOL 2
242I
21
77E
76E
75E
31
32A
4E
2E
242H
77D
76D
75D
4D
2D
242I
242H
21
77C
75B
76C
2B
4B
77E
4E
75E
76E
2E
75D
77D
2D
76D
4D
RF BYPASS
PC BOARD
8
3
2
1
6
7
5
4
J61
3
2
1
5
6
4
J62
2
6
1
5
3
4
J60
G4
282
277
283
208
1
J21
CV DAUGHTER BOARD
1
J20
213
214
215
216
217
218
219
220
221
222
E2
E1
3
4
5
6
1
2
7
8
9
10
11
12
13
14
4
1
J2
J7
J8
MOTHER
CONTROL
PC BOARD
J3
1 2 3 4 5 6
285
224
226
237
234
FRAME GROUND
ENGINE TO PCB HARNESS
238
AMMETER
5C
243
-
236C
ALT.
224
225
HOLD
COIL
SHUTDOWN SOLENOID
PULL
COIL
240 226
262 227
SOLENOID GROUND
STUD ON ENGINE
IDLE
HOLD
COIL
SOLENOID
PULL
COIL
237
254
IDLER
SWITCH
S4
256
HIGH
AUTO
-
255
HOUR METER
239B
242G
239A
PANEL TO PCB HARNESS
232F
OIL
PRESS.
S
-
228A
232B
247
232A
232G
242C
LOW
PRESS.
TEMP.
S
-
241A
242A
242B
242D
INSTRUMENT PANEL
GROUND SCREW
IN CONTROL BOX
232D
246
TEMP.
232C
229A
229B
FUEL
S
-
242G
232E
245
LOW
FUEL
242
ENGINE TO PANEL HARNESS
PANEL TO PANEL WIRES
228A
241A
242D
229A
239B
J16
6
7
3
4
5
8
9
1
2
P16
232A
232H
232
RUN
STOP
267
236A
S3
BOLT ON
SENDER
BRACKET
286
233
228
241
242E
229
OIL PRESSURE SWITCH & SENSOR
G
SENSOR
SWITCH
WK
234
OIL TEMP. SENSOR & SWITCH
SENSOR
233A
FUEL LVL.
SENSOR
SWITCH
ENGINE TO PANEL HARNESS
239
233A
285
236A
236C
239
J4
CONNECTIONS ON CONTROL BOARD
(VIEWED AS INSTALLED)
CV
BOARD
ENGINE
PROT.
BOARD
J2 J6 J5 J8 J7 J1
B1 B2 B3
227
262
232
START BUTTON
S2
231A 236B
STARTING
MOTOR
238
J21
1
J23
J4 J3
239A
245
247
233
229B
243
246
240
231A
STARTER
SOLENOID
SENSE
POS
EXC
NEG
ALTERNATOR
B1 B2 B3
ENGINE PROT.
BOARD J23
3 4 5
GND-F 5C
GND-H
6
242
7 8
(+)
(-)
J1
J5
SPI
4
3
2
1
5
6
SCI
7
8
STAINLESS STEEL
STAND-OFF
COMMON BATT.
J40
METER
PCB
FRAME GROUND
240
SELECTOR SWITCH (S8)
POSITION NAMEPLATE SETTING
1 NO FUNCTION
2 WIRE WELDING CV
3 90 MAX.
4 120 MAX.
5 180 MAX.
6 230 MAX.
7 270 MAX.
8 400 MAX.
9 50-575
12 VOLT
BATTERY
STUD ON ENGINE
MOUNT CHANNEL
STUD ON GENERATOR
MOUNT CHANNEL
J6
253
252
251
250
STUD ON
ENGINE
1 2 3 4
ENGINE GROUND
240A
5-15-98A
L11009
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
G-5
COMMANDER 400
G-6
SCHEMATIC - AMPHENOL BYPASS PC BOARD
17900 M
ELECTRICAL DIAGRAMS
TO "OUTPUT CONTROL SOURCE" SWITCH
TO MOTHER CONTROL PCB
TO "REMOTELOCAL" SWITCH
4B
2B
75B
77C
76C
1
J61
2
J61
3
J61
4
J61
5
J61
8
J61
7
J61
TP4
150V
80J
TP1
150V
80J
TP2
150V
80J
TP3
150V
80J
L4
.39mH
C4
.0047
3000V
L5
.39mH
C5
.0047
3000V
L1
.39mH
C1
.0047
3000V
L2
.39mH
C2
.0047
3000V
L6
.39mH
C6
.0047
3000V
L3
.39mH
C3
.0047
3000V
J62
5
J60
5
J60
4
J60
1
J60
2
J60
6
J60
3
J62
4
4D
J62
1
2D
J62
2
75D
J62
6
77D
J62
3
76D
4E
2E
75E
77E
76E
G-6
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
NUMBER.
UNLESS OTHERWISE SPECIFIED TOLERANCE
ON HOLES SIZES PER E-2056
ON 2 PLACE DECIMALS IS + .O2
ON 3 PLACE DECIMALS IS + .OO2
ON ALL ANGLES IS + .5 OF A DEGREE
MATERIAL TOLERANCE ("t") TO AGREE
WITH PUBLISHED STANDARDS
Ch’ge.Sht.No.
XB-UF
12-13-96
FILENAME: M17900_1AB
GENERAL INFORMATION
ELECTRICAL SYMBOLS PER E1537
CAPACITORS =
RESISTORS = Ohms (
DIODES = 1A, 400V
MFD ( .022/50V
1/4W
UNLESS OTHERWISE SPECIFIED)
UNLESS OTHERWISE SPECIFIED)
(UNLESS OTHERWISE SPECIFIED)
LABELS
SUPPLY
LAST NO. USED
R-
C-
L-
_
6
6
VOLTAGE NET
POWER SUPPLY SOURCE POINT
COMMON CONNECTION
FRAME CONNECTION
EARTH GROUND CONNECTION
DR.
THE LINCOLN ELECTRIC CO.
CLEVELAND, OHIO U.S.A.
SCALE
NONE
I.E.B. / F.V.
DATE 3/9/95 CHK.
JB
EQUIP.
TYPE
SUBJECT
COMMANDER 400 STICK & WIRE
AMPHENOL BYPASS SCHEMATIC
SUP’S’D’G.
SHT.
NO.
17900
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-7
PC BOARD ASSEMBLY - AMPHENOL BYPASS PC BOARD
ELECTRICAL DIAGRAMS
G-7
L9892-1
XXXXXXXXX
TP2
TP3
COMMANDER 400
L6
TP1
X
X
X
X
X
X
TP4
XXXXXXXXX
XXXXX
C4
XXXXX
C5
XXXXX
C1
XXXXX
C2
XXXXX
C3
XXXXX
C6
XXXXX
X
X
X
X
X
X
L4
L5
ITEM
C1, C2, C3, C4, C5, C6
J60, J62
J61
L1, L2, L3, L4, L5, L6
TP1, TP2, TP3, TP4
CAPACITORS = MFD/VOLTS
INDUCTANCE = HENRYS
REQ’D
6
2
1
6
4
PART NO.
T11577-58
S18248-6
S18248-8
T12218-9
T13640-16
L9892-1
12-13-96
IDENTIFICATION
.0047/3000V
HEADER
CONNECTOR
.39mH
80J
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-8
SCHEMATIC - AUXILIARY PROTECTION PC BOARD
ELECTRICAL DIAGRAMS
G-8
XA
12-15-95
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-9
PC BOARD ASSEMBLY - AUXILIARY PROTECTION PC BOARD
ELECTRICAL DIAGRAMS
G-9
ITEM
B4
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X X X X X X X
X X
X
X
L9749-1
X
X
X
X X
X
X
X
X
X
B5 B6
X
X
X
X
X
X X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X X X X X X X
X
X
X
B7
X
X X
X
X
X
X X X
X
X X
X X
X X
X
X
AUXILIARY PROTECTION
REQ’D PART NO.
DESCRIPTION
L9749-1
12-15-95A
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-10
SCHEMATIC - BYPASS PC BOARD
ELECTRICAL DIAGRAMS
G-10
XA
12-15-95
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-11
PC BOARD ASSEMBLY - BYPASS PC BOARD
ELECTRICAL DIAGRAMS
4.15
~.04
4.50
~.04
3.80
3.50
3.28
.82
.60
2.98
C13 xx x x x x
C12
C11
C2 x x xx x
TP3
C10 x x xxxxx
B2 B3 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x xxx x x x x xx xx xx x x xx xxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
B1 x x x x x x x x x x x x x x x x x x x x x x x x x xx x x x x x x x x x x x x
L9573-1 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
BYPASS xxx x x x x x x x x xx x x x
TP4
C3
TP2 x xx
C1 x x x x x x x
C8 x x x x
C7 x x x x x x x
C6 x x x x x
C5 x x x x x
C4 xx xx x xxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
0
L9573-1
10-11-96B
G-11
ITEM
C1,C2,C3
C4,C5,C6,C7,C8,C9,C10,C11
TP1,TP2,TP3,TP4,TP5
CAPACITORS = MFD/VOLTS
INDUCTANCE = HENRYS
REQ'D
3
15
PART NO.
S20500-3
T11577-52
5 T13640-16
IDENTIFICATION
.22/400V
.0047 or .005/1400
80J
.30
1.48
0
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-12
SCHEMATIC - CONTROL PC BOARD PART 1
ELECTRICAL DIAGRAMS
G-12
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
A485
3-27-97B
COMMANDER 400
G-13
SCHEMATIC - CONTROL PC BOARD PART 2
ELECTRICAL DIAGRAMS
G-13
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-14
PC BOARD ASSEMBLY - CONTROL PC BOARD
XXX X X X
X X X X X X
X
X X X
X
X X X X
X
X
X
X
X X
X
X
X
X
X
X X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXX
X
X
X
X
X
ELECTRICAL DIAGRAMS
ITEM REQ'D PART NO.
IDENTIFICATION ITEM REQ'D PART NO.
IDENTIFICATION
G-14
X X X X X X
X
X X X X X X
X
X X X X X X X X X X
X X X X X X X X X X
X
XX
X X X X X X X X X X X
X X
X X X X X X X X X X X
X
X
X X
X X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X X
X
X
X
X X
X
X
X X
X
X
X X
X X X
X
X
X
X X
X
X X X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X
X
X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X XXXX
X
X
X
XXXXXXXXX
X
X
X
X
X
XXXXXXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X
X X
X X
X X
X X
X
X
X
X
X
X
X
X X X X X X X XX
X X X
XXXXXXXX X
X X X X XX XX XX
X X X X
X X X X X X X X
X X X X X X X
X
X
X
X
X X X X
X
X
X X
X X X
X X
X
X
XXXXXXXXX
XXXX XXXX
XXXXXXXXX
XXXXXXXXX
XXXX XXXX
XXXXXXXXX
X
X X X X X X
X
X
X
X
X
X
X
X
X
X X X X X X X
X X X X X X X
X
X
X
X
X
X
X
XX
X X
X X
X
X
X X X
XX X X
X XX XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X X X X
X
X
X
X X
X X
X
X X X
X
X
X
X
X
X
X
X
X
X
X X X X X X X
X X X X X X
X
X X X
X X X X
X
X X
X
X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X X X X
X
X X X X
X
X
X
X
X
X X
X X
X X
X X
X X
X
X
X X X X X X
X
X
X
X X X X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X X
X
X
X X X X X X X X X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X X
X
X
X
X
X X X X X
X
X
X
X
X
X
X
X X X
X X X X
X
X
X
X
X
X
X X X X
X X X X
X X X X
X X X X
X
X
X X X
X X X
X
X X
X X
X
X
X
X
X X X X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
CAPACITORS = MFD/VOLTS
RESISTORS = OHMS
G2713-3
10-22-99B
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-15
SCHEMATIC - CV CONTROL PC BOARD
17741 M
ELECTRICAL DIAGRAMS
G-15
+10v
+10v
5
J20
8
J20 com
6
J20
12
13
X1
14
R10
100
R11
C2
0.1
50V
1.00K
com
R12
100
J21
2
V
V/A SWITCH
A
J21
5
3
J20
+15 CVSCR
5W
68
5W
68
D3
C3
0.1
50V 10K
J21
6
-CV STUD
7
J20
D2
3.32K
L1
.33mH
com
10K
Q2
100V
1A
2
J20
CV MODE ENABLE
FROM MCU
1
J20
1
OCI1
CNY17-3 5
R3
1.00K
2 6 4
C5
4
J20
+10v
CVSCR COM
475K
4
X1
33074A
11 com
C4
0.1
50V
Q1
600mA
40V
D1
10.0
C1
1.8
20V
562
DZ1
15V
1W
J21
1 SCR 1 GATE
GATE DRIVE FOR
SCR 1
562
10
J20
7
R14
15.0K
X1
6
5
R16
6.19K
R15
10.0K
R17
6.81K
com
DZ2
10V
1W
R18
26.7K
R19
28.0K
1
NOT USED
X1
2
3
8
X1
9
10
+10v com
J21
4
SCR 1 CATH
GENERAL INFORMATION
ELECTRICAL SYMBOLS PER E1537
CAPACITORS =
RESISTORS = Ohms (
MFD ( .022/50V
1/4W
UNLESS OTHERWISE SPECIFIED)
UNLESS OTHERWISE SPECIFIED)
DIODES = 1A, 400V (UNLESS OTHERWISE SPECIFIED)
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
NUMBER.
THIS SHEET CONTAINS PROPRIETARY INFORMATION OWNED BY THE LINCOLN ELECTRIC CO.
AND IS NOT TO BE REPRODUCED, DISCLOSED OR USED WITHOUT THE EXPRESS PERMISSION OF
UNLESS OTHERWISE SPECIFIED TOLERANCE
ON HOLES SIZES PER E-2056
ON 2 PLACE DECIMALS IS + .O2
ON 3 PLACE DECIMALS IS + .OO2
ON ALL ANGLES IS + .5 OF A DEGREE
MATERIAL TOLERANCE ("t") TO AGREE
WITH PUBLISHED STANDARDS
LAST CHANGE
XA
12-13-96
THE LINCOLN ELECTRIC CO.
FILE: M17741_1AE
DR.
THE LINCOLN ELECTRIC CO.
CLEVELAND, OHIO U.S.A.
SCALE
NONE
I.E.B./JB
DATE 9/14/94 CHK.
BS
LAST NO. USED
R19
C-
D-
5
3 LABELS
SUPPLY VOLTAGE NET
POWER SUPPLY SOURCE POINT
COMMON CONNECTION
FRAME CONNECTION
EARTH GROUND CONNECTION
EQUIP.
TYPE
SUBJECT
COMMANDER 400 S & W
CV CONTROL PC BRD SCHEMATIC
SUP’S’D’G.
SHT.
NO.
M 17741
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-16
PC BOARD ASSEMBLY - CV CONTROL PC BOARD
XXX
XXX
XXX
XXX
J20
L1
R12
R9
R8
C5
R4
Q1
D2
X
X
X
X
R7
R6
X
X
X
X
ELECTRICAL DIAGRAMS
ITEM REQ’D PART NO.
DESCRIPTION
G-16
CAPACITORS = MFD/VOLTS
RESISTORS = OHMS
L9560
12-13-96
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-17
SCHEMATIC - ENGINE PROTECTION PC BOARD
17500 M
ELECTRICAL DIAGRAMS
G-17
FROM OIL TEMP SWITCH
P23
5
FROM FUEL LEVEL SENDER
POST ON FUEL GAUGE
P23
6
R1
10.0
OIL TEMP SWITCH F.B.
COMMON (EPD)
C1
0.1
50V
+5V BATT
COMMON (EPD)
TO OIL TEMP SHUT-
DOWN LOGIC INPUT
6
P22
P22
9
P22
2
P22
10
P22
3
5
6
7
8
3
4
1
2
I0
I1
I2
I3
I4
I5
I6
GND
X3
O3
O4
O5
O6
MC1413BP
CLAMP
O0
O1
O2
16
15
14
13
12
11
10
9
R26
R28
R30
R32
267
267
267
267
R27
R29
R31
R33
267
267
267
267
P23
8
P23
3
P23
7
P23
4
TO ALT
LED
TO OIL
PRESS LED
TO OIL
TEMP LED
TO FUEL
LVL LED
4.75K
FUEL LEVEL F.B.
4.75K
CONTROL
PCB
D2 D3 D4 D5
LAMP DRIVER
DZ3
20V
1W
DZ5
20V
1W
4.75K
C2
0.1
50V
DZ1
10V
1W
R6
4.75K
1
5K
2
CW
3
8
9
X1
LM2901
R9
68.1K
14
TO FUEL SHUT-
DOWN LOGIC INP
12
P22
+12V BATT.
1
P22
COMMON (EPD)
DZ4
20V
1W
COMMON (EPD)
DZ6
20V
1W
P22
13
P22
8
COMMON (EPD)
22.1K
3.92K
+5V BATT
+5V BATT
P22
11
COMMON (EPD)
TO LAMPS
ON/OFF INPUT
4
P22
P23
2
COMMON (EPD)
+5V BATT
10.0K
2 SEC LAMPS
ON TEST TIMER
1.00K
51.1K
D1
LM2901
FROM SENSE
CONNECTION ON ALT
P23
1 R10
3.01K
DZ2
10V
1W
+5V BATT
P22
5
P22
7
TO COMMON
(BATT)
COMMON (EPD)
ALT VOLTAGE F.B.
C3
0.1
50V
COMMON (EPD)
R12
4.75K
5.11K
6
X1
LM2901
1
10.0K
TO ALT SHUT-
DOWN LOGIC INP
14
P22
Q1
2N4401
R25
1.00K
2
X1
R18
10.0K
4
5
R20
4.75K
C5
0.1
50V
4.75K
C6
27
35V
7
X1
LM2901
1.00K
C4
0.1
50V
+5V BATT
3
12
C10
COMMON (EPD)
4.75K
COMMON (EPD)
10
11
X1
LM2901
COMMON (EPD)
13
COMMON (EPD) COMMON (EPD)
R15
22.1K
GENERAL INFORMATION FILE: M17500_1BA
ELECTRICAL SYMBOLS PER E1537
CAPACITORS = MFD ( .022/50V
RESISTORS = Ohms (
DIODES = 1A, 400V
1/4W
UNLESS OTHERWISE SPECIFIED)
UNLESS OTHERWISE SPECIFIED)
(UNLESS OTHERWISE SPECIFIED)
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
NUMBER.
LAST NO. USED
R34
C-
D-
10
5
DZ-
X- 3
6
THIS SHEET CONTAINS PROPRIETARY INFORMATION OWNED BY THE LINCOLN ELECTRIC CO.
AND IS NOT TO BE REPRODUCED, DISCLOSED OR USED WITHOUT THE EXPRESS PERMISSION OF
UNLESS OTHERWISE SPECIFIED TOLERANCE
ON HOLES SIZES PER E-2056
ON 2 PLACE DECIMALS IS + .O2
ON 3 PLACE DECIMALS IS + .OO2
ON ALL ANGLES IS + .5 OF A DEGREE
MATERIAL TOLERANCE ("t") TO AGREE
WITH PUBLISHED STANDARDS
Ch’ge.Sht.No.
12-15-95A
THE LINCOLN ELECTRIC CO.
DR.
THE LINCOLN ELECTRIC CO.
CLEVELAND, OHIO U.S.A.
SCALE
NONE
B.K.
DATE 05-12-95 CHK.
EQUIP.
TYPE
SUBJECT
FV
LABELS
SUPPLY VOLTAGE NET
POWER SUPPLY SOURCE POINT
COMMON CONNECTION
FRAME CONNECTION
EARTH GROUND CONNECTION
COMMANDER 400
ENGINE PROTECTION P.C. BD. SCHEMATIC
SUP’S’D’G.
SHT.
NO.
17500
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-18
PC BOARD ASSEMBLY - ENGINE PROTECTION PC BOARD
ELECTRICAL DIAGRAMS
G-18
ITEM REQ’D PART NO.
DESCRIPTION
L9596-1
XXX
XXX
XXX
XXX
XXX
COMMANDER 400
ENGINE PROTECTION
Q1
C6
X3
X1
R8
R7
R14
C4
R13
R12
CAPACITORS = MFD/VOLTS
RESISTORS = OHMS
L9596-1
8-14-98C
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-19
SCHEMATIC - METER PC BOARD
17637
M
+15V R31
20.0
R32
20.0
R33
20.0
R34
20.0
R39
200
R35
20.0
R36
20.0
R37
20.0
R38
20.0
2
Q5
3A
100V
3
1
R40
10.0
R41
10.0
R42
10.0
ELECTRICAL DIAGRAMS
D1
+5V
IN
C9
.33
50V
X6
GND
OUT
C10
0.1
50V
C11
4.7
35V
+5V
14
X1
74HC164
7
C2
14
X2
74HC164
7
C3
14
X3
74HC164
7
C4
14
X4
54HC74
7
C7
14
X5
HEXINV
7
C8
G-19
DZ2
10V
1W
+15V
4.75K
Q2
2N4401
R30
DZ1
15V
1W
+5V
D2
Q4
1A
100V
3 8
1
2
4
5
6
7
9
10
LED1
3 8
1
2
4
5
6
7
9
10
LED2
3 8
1
2
4
5
6
7
9
10
LED3
Q1
2N4401
C1
.0047
50V
2N4403
Q3
R1
2.21K
+5V
3.01K
3.01K
DATA
CLOCK
+15V IN
COMMON
J40
4
1
X5
J40
1
J40
3
R25
+15V
R26
J40
2
C12
0.1
50V
2
C5
330p
50V
3
X5
C6
330p
50V
9
X5
8
J40
5
4 5
X5
+5V
6
10
11
12
3
4
5
6
Q
A
Q
B
Q
C
Q
D
Q
E
Q
F
Q
G
X1
74HC164
A1
A2
CLK
R
Q
H
8
9
13
1
2
+5V
13
X5
12 11
X5
10
+5V
3
4
5
1
2
6
7
RESET 1
DATA 1
CLOCK 1
SET 1
Q1
/Q1
GND
X4
54HC74
VCC
14
RESET 2
DATA 2
CLOCK 2
SET 2
Q2
N.C.
10
9
8
13
12
11
+5V
10
11
12
3
4
5
6
Q
A
Q
B
Q
C
Q
D
Q
E
Q
F
Q
G
X2
74HC164
A1
A2
CLK
R
Q
H
8
9
13
1
2
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
NUMBER.
UNLESS OTHERWISE SPECIFIED TOLERANCE
ON HOLES SIZES PER E-2056
ON 2 PLACE DECIMALS IS + .O2
ON 3 PLACE DECIMALS IS + .OO2
ON ALL ANGLES IS + .5 OF A DEGREE
MATERIAL TOLERANCE ("t") TO AGREE
WITH PUBLISHED STANDARDS
Ch’ge.Sht.No.
XA
12-15-95A
9-27-96F
+5V
10
11
12
3
4
5
6
Q
A
Q
B
Q
C
Q
D
Q
E
Q
F
Q
G
X3
74HC164
A1
A2
CLK
R
Q
H
8
9
13
1
2
GENERAL INFORMATION
ELECTRICAL SYMBOLS PER E1537
CAPACITORS =
RESISTORS = Ohms (
MFD ( .022/50V
1/4W
UNLESS OTHERWISE SPECIFIED)
UNLESS OTHERWISE SPECIFIED)
DIODES = 1A, 400V (UNLESS OTHERWISE SPECIFIED)
NOTE: ALL UNMARKED RESISTORS = 100 OHMS
LABELS
SUPPLY
LAST NO. USED
R-
C-
42
12
D- 2
Q-
DZ-
5
2
VOLTAGE NET
POWER SUPPLY SOURCE POINT
COMMON CONNECTION
FRAME CONNECTION
EARTH GROUND CONNECTION
FILE: M17637_1AC
DR.
THE LINCOLN ELECTRIC CO.
BK
CLEVELAND, OHIO U.S.A.
SCALE NONE
DATE 05-12-94 CHK.
FV
EQUIP.
TYPE
SUBJECT
SUP’S’D’G.
COMMANDER 400
METER P.C. BOARD SCHEMATIC
SHT.
NO.
17637
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-20
PC BOARD ASSEMBLY - METER PC BOARD
ITEM
ELECTRICAL DIAGRAMS
REQ’D PART NO.
IDENTIFICATION
Q1
Q2
Q3
X6
L9684-1 COMMANDER 400 METER
R40
R41
R42
Q5
X1
C11
C10
C9
X5
R16
R15
R14
R13
R5
LED1 LED2 LED3
C12
Q4
X4
X2
C3
X3
G-20
CAPACITORS = MFD/VOLTS
RESISTORS = OHMS
L9684-1
9-27-96F
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-21
SCHEMATIC - REMOTE PROTECTION PC BOARD
17948 M
ELECTRICAL DIAGRAMS
G-21
4B
J61
2
TO "OUTPUT CONTROL
SOURCE" SWITCH S6
2B
J61
3
TO MOTHER CONTROL PCB 75B
J61
4
TO "REMOTE/LOCAL"
SWITCH S1
77C
J61
5
76C
J61
8
1
J61
6
J61
7
J61
TP4
150V
80J
TP1
150V
80J
TP2
150V
80J
TP3
150V
80J
L1
.39mH
C1
.0047
3000V
L2
.39mH
C2
.0047
3000V
L3
.39mH
C3
.0047
3000V
L4
.39mH
C4
.0047
3000V
L5
.39mH
C5
.0047
3000V
FRAME
FRAME
FRAME
FRAME
FRAME
J60
4
J60
1
J60
2
J60
6
J60
3
4D
2D
75D
77D
76D
J60
5
TO REMOTE CONTROL
AMPHENOL
GENERAL INFORMATION
ELECTRICAL SYMBOLS PER E1537
CAPACITORS = MFD ( .022/50V
RESISTORS = Ohms ( 1/4W
UNLESS OTHERWISE SPECIFIED)
UNLESS OTHERWISE SPECIFIED)
DIODES = 1A, 400V (UNLESS OTHERWISE SPECIFIED)
NOTES :
N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE
WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY
NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE
NUMBER.
THIS SHEET CONTAINS PROPRIETARY INFORMATION OWNED BY THE LINCOLN ELECTRIC CO.
AND IS NOT TO BE REPRODUCED, DISCLOSED OR USED WITHOUT THE EXPRESS PERMISSION OF
UNLESS OTHERWISE SPECIFIED TOLERANCE
ON HOLES SIZES PER E-2056
ON 2 PLACE DECIMALS IS + .O2
ON 3 PLACE DECIMALS IS + .OO2
ON ALL ANGLES IS + .5 OF A DEGREE
MATERIAL TOLERANCE ("t") TO AGREE
WITH PUBLISHED STANDARDS
Ch’ge.Sht.No.
XA
12-15-95A
THE LINCOLN ELECTRIC CO.
DR.
FILE: M17948_1AA
THE LINCOLN ELECTRIC CO.
CLEVELAND, OHIO U.S.A.
SCALE
NONE
BK DATE 5-16-95 CHK.
FV
LAST NO. USED
L5
C5
TP 4 LABELS
SUPPLY VOLTAGE NET
POWER SUPPLY SOURCE POINT
COMMON CONNECTION
FRAME CONNECTION
EARTH GROUND CONNECTION
EQUIP.
TYPE
SUBJECT
COMMANDER
REMOTE PROTECTION P.C. BD. SCHEMATIC
SUP’S’D’G.
SHT.
NO.
M 17948
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
COMMANDER 400
G-22
PC BOARD ASSEMBLY - REMOTE PROTECTION PC BOARD
ELECTRICAL DIAGRAMS
REMOTE
PROTECTION
X
X
X X
X
X
X
X
XXXXX
X
X
X
X
X
XXXXXX
C1
X
XXXXXX
C2
X
X
X
X
X
X
L9924-1
X
XXXXX
X
X
X
X
TP4 X
L4
L1
X
XXXXXX
C3
X
XXXXXX
C5
X
XXXXXX
C4
XXXXXX
X
X
X
ITEM
C1, C2, C3, C4, C5
J60
J61
L1, L2, L3, L4, L5
TP1, TP2, TP3, TP4
ITEM REQ’D
5
1
1
5
4
PART NO.
T11577-58
S18248-6
S18248-8
T12218-9
T13640-16
IDENTIFICATION
.0047/3000V
HEADER
CONNECTOR
.39mH
80J
L9924-1
12-15-95A
G-22
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
G-23
SCHEMATIC - SNUBBER PC BOARD
ELECTRICAL DIAGRAMS
G-23
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.
1-16-98E
COMMANDER 400
G-24
PC BOARD ASSEMBLY - SNUBBER PC BOARD
~.04
4.70
4.40
3.50
3.30
X
X
X X
X
X
X
X
X
X
X
XXXXXXX
X
X
X
X
X
X
XXXXX
X
X
X
ELECTRICAL DIAGRAMS
~.04
3.00
ITEMD
ITEM
L9572-1
CAPACITORS = MFD/VOLTS
INDUCTANCE = HENRYS
REQ'D PART NO.
IDENTIFICATION
G-24
L
9572-1
12-15-95A
1-16-98E .30
0
COMMANDER SNUBBER
0 .30
2.70
NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.
COMMANDER 400
SVM ERROR REPORTING FORM
We need to know if there are errors in our manuals. We also value any suggestions as to additional tests or procedures that would make this SVM a better tool for you.
If you discover new or different “Problems or Symptoms” that are not covered in the three column troubleshooting chart, please share this information with us. Please include the machine’s code number and how the problem was resolved.
Thank You,
Technical Services Group
Lincoln Electric Co.
22801 ST. Clair Ave.
Cleveland, Ohio 44117-1199
FAX 216-481-2309
SVM Number ___________________________
Page Number if necessary__________________
Your Company__________________________
Your Name_____________________________
Please give detailed description below:
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
SD287 01/99
advertisement