FH Series Vision System Operation Manual for Sysmac Studio

FH Series Vision System Operation Manual for Sysmac Studio
Vision Sensor
FH Series
Vision System
Operation Manual for Sysmac Studio
FH-1………
FH-1………-……
FH-3………
FH-3………-……
Z343-E1-08
NOTE
• All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise,
without the prior written permission of OMRON.
• No patent liability is assumed with respect to the use of the information contained herein. Moreover,
because OMRON is constantly striving to improve its high-quality products, the information contained
in this manual is subject to change without notice. Every precaution has been taken in the preparation
of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any
liability assumed for damages resulting from the use of the information contained in this publication.
Trademarks
• Sysmac and SYSMAC are trademarks or registered trademarks of OMRON Corporation in Japan and
other countries for OMRON factory automation products.
• This software is based in part on the work of the Independent JPEG Group.
• Microsoft, Windows, Windows Vista, Excel, and Visual Basic are either registered trademarks or
trademarks of Microsoft Corporation in the United States and other countries.
• Intel, Core and Pentium are trademarks of Intel Corporation in the U.S. and/or other countries.
• EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation
GmbH, Germany.
• ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks of ODVA.
• The SD and SDHC logos are trademarks of SD-3C, LLC.
• QR Code is a registered trademark of DENSO WAVE INCORPORATED.
• MELSEC is a registered trademarks of Mitsubishi Electric Corporation.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
Copyrights
Microsoft product screen shots reprinted with permission from Microsoft Corporation.
Manual Structure
Manual Structure
Page Structure
The following page structure is used in this manual.
Mounting Units
Level 1 heading
Level 2 heading
Level 3 heading
Connecting Controller Components
Gives the current
headings.
4 Installation and Wiring
Level 2 heading
Level 3 heading
4-3
4-3-1
The Units that make up an NJ-series Controller can be connected simply by pressing the Units together
and locking the sliders by moving them toward the back of the Units. The End Cover is connected in the
same way to the Unit on the far right side of the Controller.
A step in a procedure
1
Join the Units so that the connectors fit exactly.
Hook
Indicates a procedure.
Hook holes
Connector
4-3 Mounting Units
4
The yellow sliders at the top and bottom of each Unit lock the Units together. Move the sliders
toward the back of the Units as shown below until they click into place.
Move the sliders toward the back
until they lock into place.
Lock
Release
Slider
Special information
Icons indicate
precautions, additional
information, or reference
information.
Manual name
4-3-1 Connecting Controller Components
2
Page tab
Gives the number
of the main section.
Precautions for Correct Use
The sliders on the tops and bottoms of the Power Supply Unit, CPU Unit, I/O Units, Special I/O
Units, and CPU Bus Units must be completely locked (until they click into place) after connecting
the adjacent Unit connectors.
NJ-series CPU Unit Hardware User’s Manual (W500)
4-9
This illustration is provided only as a sample. It may not literally appear in this manual.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1
Manual Structure
Special Information
Special information in this manual is classified as follows:
Precautions for Safe Use
Precautions on what to do and what not to do to ensure safe usage of the product.
Precautions for Correct Use
Precautions on what to do and what not to do to ensure proper operation and performance.
Additional Information
Additional information to read as required.
This information is provided to increase understanding or make operation easier.
Version Information
Information on differences in specifications and functionality for CPU Units with different unit
versions and for different versions of the Sysmac Studio is given.
Note References are provided to more detailed or related information.
Terminology
• For descriptions of the Controller terms that are used in this manual, refer to information on terminology in the manuals that are listed in Related Manuals of Sysmac Studio Version 1 Operation Manual
(Cat. No. W504-E1-08 or later).
• For descriptions of the FH/FZ5 Sensor controller terms that are used in this manual, refer to information on terminology in Vision System FH/FZ5 series User's Manual (Cat. No. Z365).
2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Sections in this Manual
Sections in this Manual
1
2
Overview
Basic Operations
10
A
1
10
2
A
3
I
Troubleshooting
Appendices
4
3
Connecting with
a Vision Sensor
4
Configuring Measurement Settings
6
5
Designing Exchange with External Devices
7
6
I
Index
5
8
Online Debugging
9
7
Offline Debugging
8
Other Useful Functions
9
Limitations
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3
Terms and Conditions Agreement
Terms and Conditions Agreement
Warranty, Limitations of Liability
Warranties
 Exclusive Warranty
Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in
writing by Omron). Omron disclaims all other warranties, express or implied.
 Limitations
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF
THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based
on infringement by the Products or otherwise of any intellectual property right.
 Buyer Remedy
Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally
shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal
to the purchase price of the non-complying Product; provided that in no event shall Omron be
responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products
unless Omron’s analysis confirms that the Products were properly handled, stored, installed and
maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of
any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies
shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on
which liability is asserted.
4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Terms and Conditions Agreement
Application Considerations
Suitability of Use
Omron Companies shall not be responsible for conformity with any standards, codes or regulations
which apply to the combination of the Product in the Buyer’s application or use of the Product. At
Buyer’s request, Omron will provide applicable third party certification documents identifying ratings
and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Programmable Products
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or
any consequence thereof.
Disclaimers
Performance Data
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for
the user in determining suitability and does not constitute a warranty. It may represent the result of
Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications
Product specifications and accessories may be changed at any time based on improvements and other
reasons. It is our practice to change part numbers when published ratings or features are changed, or
when significant construction changes are made. However, some specifications of the Product may be
changed without any notice. When in doubt, special part numbers may be assigned to fix or establish
key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
5
Safety Precautions
Safety Precautions
For details on Safety Precautions, refer to Safety Precautions in Vision System FH/FZ5 Series User's
Manual (Cat. No. Z365).
6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Precautions for Safe Use
Precautions for Safe Use
For details on Precautions for Safe Use, refer to Precautions for Safe Use in Vision System FH/FZ5
Series User's Manual (Cat. No. Z365).
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7
Precautions for Correct Use
Precautions for Correct Use
For details on Precautions for Correct Use, refer to Precautions for Correct Use in Vision System
FH/FZ5 Series User's Manual (Cat. No. Z365).
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Regulations and Standards
Regulations and Standards
For details on Regulations and Standards, refer to Regulations and Standards in Vision System FH/FZ5
Series User's Manual (Cat. No. Z365).
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9
Related Manuals
Related Manuals
The following manuals are related to the FH-series Sensor Controllers. Use these manuals for reference.
Name of Manual
Vision System FH Instruction
Sheet
Cat. No.
9607479-9
Model
FH-1
FH-1-
FH-3
Purpose
Contents
To confirm the safety and
usage precautions of the
Vision System FH series
Sensor Controller.
Describes the definitions of basic terms,
meaning of signal words, and precautions
for correct use of FH series in the manual.
To confirm the safety and
usage precautions of the
Vision System FH-Lite
series Sensor Controller.
Describes the definitions of basic terms,
meaning of signal words, and precautions
for correct use of FH-L series in the manual.
To confirm the setup procedures, safety and
usage precautions of the
Vision System FZ5-600,
FZ5-1100 series Sensor
Controller, including I/O
setup and wiring.
Describes the definitions of basic terms,
meaning of signal words, and precautions
for correct use of FZ5-600, FZ5-1100
series in the manual.
To confirm the setup procedures, safety and
usage precautions of the
Vision System FZ5-800,
FZ5-1200 series Sensor
Controller, including I/O
setup and wiring.
Describes the definitions of basic terms,
meaning of signal words, and precautions
for correct use of FZ5-800, FZ5-1200
series in the manual.
To confirm the setup procedures, safety and
usage precautions of the
Vision System FZ5-L
Series Sensor Controller,
including I/O setup and
wiring.
Describes the definitions of basic terms,
meaning of signal words, and precautions
for correct use of FZ5-L series in the manual.
FH-3-
Vision System FH-L Instruction Sheet
9606631-1
Vision System FZ5 Instruction
Sheet
9524422-4
FH-L
FH-L-
FZ5-6
FZ5-6-
FZ5-11
FZ5-11-
Vision System FZ5 Instruction
Sheet
9308317-7
FZ5-8
FZ5-8-
FZ5-12
FZ5-12-
Vision System FZ5-L Instruction Sheet
10
9910002-2
FZ5-L35
FZ5-L35-
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Related Manuals
Name of Manual
Vision System FH/FZ5 Series
User’s Manual
Cat. No.
Z365
Model
FH-1
FH-1-
FH-3
Vision System FH/FZ5 series
Hardware Setup Manual
Z366
FH-3-
FH-L
FH-L-
FZ5-L35
Vision System FH/FZ5 series
Macro Customize Functions
Programming Manual
Z367
Vision System FH/FZ5 series
Processing Item Function Reference Manual
Z341
FZ5-L35-
FZ5-6
FZ5-6-
FZ5-8
FZ5-8-
FZ5-11
FZ5-11-
Vision System FH/FZ5 Series
User’s Manual for Communications Settings
Z342
FZ5-12
FZ5-12-
Propose
Contents
When User want to know
how to setup the Sensor
Controller of the Vision
System FH/FZ5 series.
Describes the soft functions, setup, and
operations to use Sensor Controller of the
Vision System FH/FZ5 series.
When User want to know
about the Hard-ware
specifications or to setup
the Sensor Controller of
the Vision System
FH/FZ5 series.
Describes FH/FZ5 series specifications,
dimensions, part names, I/O information,
installation information, and wiring information.
When User operate or
programming using
Macro Customize functions.
Describes the functions, settings, and
operations for using Macro Customize
function of the FH/FH5-series.
When User confirm the
details of each processing items at the create the
measurement flow or
operate it.
Describes the software functions, settings, and operations for using
FH/FH5-series.
When User confirm the
setting of communication
functions.
Describes the functions, settings, and
communications methods for communicating between FH/FH5 series.
The following communication protocol are
described.
Parallel, PLC Link, EtherNet/IP, EtherCAT,
and Non-procedure
Vision System FH Series
Operation Manual for Sysmac
Studio
Z343
FH-1
FH-1-
FH-3
When User connect to NJ
series via EtherCAT communication.
Describes the operating procedures for
setting up and operating FH series Vision
Sensors from the Sysmac Studio FH
Tools.
FH-3-
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
11
CONTENTS
CONTENTS
Manual Structure ...................................................................................................... 1
Page Structure ............................................................................................................................................. 1
Special Information ...................................................................................................................................... 2
Terminology ................................................................................................................................................. 2
Sections in this Manual ........................................................................................... 3
Terms and Conditions Agreement .......................................................................... 4
Warranty, Limitations of Liability .................................................................................................................. 4
Application Considerations .......................................................................................................................... 5
Disclaimers .................................................................................................................................................. 5
Safety Precautions ................................................................................................... 6
Precautions for Safe Use ......................................................................................... 7
Precautions for Correct Use.................................................................................... 8
Regulations and Standards ..................................................................................... 9
Related Manuals ..................................................................................................... 10
Manual Revision History........................................................................................ 17
Section 1
Overview
1-1
Supported Models ................................................................................................................. 1-2
1-2
Project Management ............................................................................................................. 1-3
1-2-1
1-2-2
Section 2
Basic Operations
2-1
Basic Design Flow 1.............................................................................................................. 2-3
2-2
Basic Design Flow 2.............................................................................................................. 2-5
2-3
Creating a New Project ......................................................................................................... 2-6
2-3-1
2-3-2
2-3-3
2-4
Creating a New Project File from the Project Window ................................................................ 2-6
Adding FH Device to a Project .................................................................................................... 2-8
Deleting FH Device from a Project.............................................................................................. 2-8
Description of Screen Components..................................................................................... 2-9
2-4-1
2-4-2
2-4-3
2-4-4
2-4-5
2-4-6
12
Project data ................................................................................................................................. 1-4
Project Data Handling in Different System Configurations.......................................................... 1-5
Application Window..................................................................................................................... 2-9
Menu Bar................................................................................................................................... 2-10
Toolbar ...................................................................................................................................... 2-10
Multiview Explorer ..................................................................................................................... 2-10
Edit Pane................................................................................................................................... 2-12
Toolbox...................................................................................................................................... 2-24
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
CONTENTS
2-5
Basic Operations of Scene Data ........................................................................................ 2-25
2-5-1
2-5-2
2-5-3
2-5-4
2-5-5
2-5-6
2-5-7
2-6
Basic Operations of Flow Editing ...................................................................................... 2-30
2-6-1
2-6-2
2-6-3
2-7
Section 3
3-2
Adding FH Series Vision Sensor on the Network to a Project .......................................... 3-3
Establishing an Online Connection with a Vision Sensor ................................................. 3-4
Configuring Measurement Settings
Overview of Processing Units .............................................................................................. 4-2
4-1-1
4-1-2
4-1-3
4-1-4
4-1-5
4-1-6
4-1-7
4-2
Ending a Connection in the Sensor Connection Screen............................................................3-11
Ending a Connection in the Multiview Explorer .........................................................................3-11
Logging in to a Registered User's Account ...................................................................... 3-12
Section 4
4-1
Transferring Project Data to the Sensor ..................................................................................... 3-8
Transferring Setting data in the Sensor to a Project ................................................................... 3-9
Ending a Connection with a Vision Sensor ...................................................................... 3-11
3-4-1
3-4-2
3-5
Establishing an Online Connection from the Sensor Connection Screen................................... 3-4
Establishing an Online Connection from the Multiview Explorer ................................................ 3-6
Synchronizing Project Data and Sensor Setting Data ....................................................... 3-8
3-3-1
3-3-2
3-4
Synchronized Project Data ....................................................................................................... 2-40
Saving and Loading the Settings Data for the FH Sensor Controller ....................................... 2-41
Transferring Data from the Sysmac Studio ............................................................................... 2-42
Transferring Data to the Sysmac Studio ................................................................................... 2-44
Connecting with a Vision Sensor
3-2-1
3-2-2
3-3
List of Functions Provided with the FH Tool.............................................................................. 2-35
Comparison with FH Series Unit Functions .............................................................................. 2-38
Precautions on Synchronization through an NJ/NX/NY-series Controller..................... 2-39
2-8-1
2-8-2
2-8-3
2-8-4
3-1
Adding a Processing Unit ......................................................................................................... 2-31
Managing Processing Units ...................................................................................................... 2-32
Searching for a Processing Unit ............................................................................................... 2-34
Function List ........................................................................................................................ 2-35
2-7-1
2-7-2
2-8
Switching Scenes ..................................................................................................................... 2-26
Managing Scenes ..................................................................................................................... 2-26
Entering Scene Information ...................................................................................................... 2-27
Searching for a Scene .............................................................................................................. 2-27
Switching Scene Groups .......................................................................................................... 2-27
Managing Scene Groups .......................................................................................................... 2-28
Entering Scene Group Information ........................................................................................... 2-29
Input Image................................................................................................................................. 4-2
Measurement.............................................................................................................................. 4-2
Compensate Image .................................................................................................................... 4-2
Support Measurement ................................................................................................................ 4-3
Branch ........................................................................................................................................ 4-3
Output Result.............................................................................................................................. 4-3
Display Result............................................................................................................................. 4-3
Editing a Processing Unit ..................................................................................................... 4-4
4-2-1
4-2-2
4-2-3
4-2-4
4-2-5
4-2-6
4-2-7
4-2-8
Parameter Settings ..................................................................................................................... 4-5
Editing an Area ........................................................................................................................... 4-6
Color Extraction .......................................................................................................................... 4-9
Color ......................................................................................................................................... 4-10
Binary........................................................................................................................................ 4-10
Detection Point/Reference Point................................................................................................4-11
List .............................................................................................................................................4-11
Image Control Area....................................................................................................................4-11
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
13
CONTENTS
Section 5
5-1
Designing Exchange with External Devices
Setting Procedure.................................................................................................................. 5-3
Section 6
6-1
Online Debugging
Performing Test Measurement ............................................................................................. 6-2
6-1-1
6-1-2
6-1-3
6-2
Measuring Camera Images......................................................................................................... 6-2
Measuring File Images in the RAMDisk or the External Memory, i.e. USB Memory of the Vision
Sensor6-3
Measuring Logging Images in the Vision Sensor Memory.......................................................... 6-3
Checking Measurement Results .......................................................................................... 6-4
6-2-1
6-2-2
6-2-3
Checking Detailed Results .......................................................................................................... 6-4
Changing the Image Display Settings ......................................................................................... 6-6
Checking Multiple Measurement Images at the Same Time....................................................... 6-6
6-3
Checking Result Output........................................................................................................ 6-7
6-4
Saving Measurement Results............................................................................................... 6-8
6-5
Saving Settings Data ............................................................................................................. 6-9
6-6
Loading Settings Data......................................................................................................... 6-10
Section 7
Offline Debugging
7-1
Performing Offline Simulation of Sensor Measurement Operation .................................. 7-2
7-2
Offline Debugging of the Sensor Control Program and Sensor Operation (Only When Using EtherCAT Connection)7-3
7-2-1
7-2-2
Section 8
Control Signals Supported with Offline Debugging ..................................................................... 7-4
Offline Debugging Procedure for the Sensor Control Program................................................... 7-5
Other Useful Functions
8-1
Using the Command Customize Setting Tool ..................................................................... 8-2
8-2
Using the Calibration Support Tool ..................................................................................... 8-3
8-3
Using the File Save Tool ....................................................................................................... 8-4
8-3-1
8-3-2
8-3-3
Opening the File Save Tool ......................................................................................................... 8-4
Copying a File ............................................................................................................................. 8-4
Saving a Logging Image as a File............................................................................................... 8-6
8-4
Using the User Data Setting Tool ......................................................................................... 8-7
8-5
Changing the System Environment ..................................................................................... 8-8
8-6
Help....................................................................................................................................... 8-10
8-7
Using the Security Setting Tool.......................................................................................... 8-11
8-8
Using the Scene Group Saving Destination Setting Tool ................................................ 8-12
8-9
Using the Image File Save Tool .......................................................................................... 8-13
8-9-1
8-9-2
8-9-3
Opening the Image File Save Tool ............................................................................................ 8-13
Saving the Image File ............................................................................................................... 8-14
Saving the Logged Images to Files........................................................................................... 8-15
8-10 Using the Registered image Manager ............................................................................... 8-16
8-11 Using the Update Standard Position Tool ......................................................................... 8-17
8-12 Using the Conversion Scene Group Data Tool ................................................................. 8-18
8-13 Using the Scene Control Macro Tool ................................................................................. 8-19
14
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
CONTENTS
8-14 Print the Settings................................................................................................................. 8-20
8-15 Using the Conveyor Panorama Display tool..................................................................... 8-21
8-16 Using the Conveyor Calibration Wizard tool .................................................................... 8-22
8-17 Using the Calibration Plate Print tool ................................................................................ 8-23
Section 9
Limitations
9-1
Limitations ............................................................................................................................. 9-2
9-2
Synchronization with the NJ/NX/NY-series Controllers..................................................... 9-5
Section 10
Troubleshooting
10-1 Troubleshooting for EtherCAT ........................................................................................... 10-2
10-2 Sysmac Error Status ........................................................................................................... 10-3
Appendices
A-1 Sysmac Device Features ......................................................................................................A-2
A-1-1
A-1-2
A-1-3
A-1-4
A-1-5
Sysmac Error Status ................................................................................................................... A-2
Saving the Node Address Setting............................................................................................... A-3
Serial Number Display ................................................................................................................ A-4
Compliance with ESI Specification (ETG.2000 S (R) V1.0.1) ..................................................... A-4
SII Data Check............................................................................................................................ A-4
Index
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
15
CONTENTS
16
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Manual Revision History
Manual Revision History
The manual revision symbol is appended to the manual number on the front cover and back cover.
Z343-E1-08
Revision Symbol
Revision Symbol
01
02
Revision Date
June 2013
September 2013
03
January 2014
04
July 2014
05
October 2015
06
07
April 2016
April 2017
08
June 2017
Reason for Revision and Revised Page
First edition
Added offline debugging function, Support for software version 5.1
of the FH sensor controller.
Added additional supported processing units, added support for
multiple FH unit settings, added a security function, expanded data
transfer functions.
Additions for software version upgrade. Support for software version 5.20 of the FH sensor controller.
Additions for software version upgrade and FH Sensor Controller
ver.5.50.
Corrections sentences related other manuals.
Additions for software version upgrade and FH Sensor Controller
ver.5.71.
Additions for software version upgrade and FH Sensor Controller
ver.5.72.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
17
Manual Revision History
18
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1
Overview
This Chapter describes the functional specifications of the Sysmac Studio FH tools
(hereinafter referred to as "FH tools").
1-1 Supported Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-2 Project Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1-2-1
1-2-2
Project data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Project Data Handling in Different System Configurations . . . . . . . . . . . . . . . . 1-5
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1-1
1 Overview
1-1
Supported Models
The FH tool supports the following models in the FH Vision Sensor series.
Connection Device Type
FH-3050
FH-3050-10
FH-3050-20
FH-1050
FH-1050-10
FH-1050-20
1-2
Description
High-speed controller for 2-channel camera type
High-speed controller for 4-channel camera type
High-speed controller for 8-channel camera type
Standard controller for 2-channel camera type
Standard controller for 4-channel camera type
Standard controller for 8-channel camera type
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1 Overview
Project Management
Sysmac Studio manages the configuration information of each of the controller, servo, and vision sensor devices on a project basis.
Here, we describe the contents of the project data related to the FH Sensor Controller and how the data
is managed.
Project data
Data related to the NJ/NX/NY-series Controller
Data related to the FH sensor controller
Data related to Servo Drives
Data related to other vision sensors
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1-3
1-2 Project Management
1-2
1
1 Overview
1-2-1
Project data
Eight FH vision sensor series devices can be registered to one project.
In the FH sensor controller series, the following types of data provided by Sysmac Studio are managed
as project data.
• Scene group data (scene data)
• System data
• Tool data (communications command macros, security settings, and other data)
By using the Multi-line Random-trigger Mode, the FH sensor controller independently processes multiple processing lines at the same time. In Multi-line Random Trigger mode, the above data is controlled
separately for each line.
Project data manages this data together as one batch. These data can also be exported and imported
individually as file data.
Project data
FH sensor
Line
Line
Line
Scene group data
Scene group data
Scene group data
Scene data
Scene data
Scene data
Tool data
Command
customize
data
1-4
System
data
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1 Overview
Project Data Handling in Different System Configurations
The contents of the Sysmac Studio project data and the data being synchronized varies depending on
the connection method (i.e., Ethernet direct connection or connection through an NJ/NX/NY-series
Controller) between the FH sensor controller and the computer that runs Sysmac Studio. Particularly
with the connection through an NJ/NX/NY-series Controller, there are restrictions on some Sysmac Studio functions. Be sure you understand the following before operation.
Refer to 2-8 Precautions on Synchronization through an NJ/NX/NY-series Controller on page 2-39.
System
configuration
Sysmac Studio
NJ/NX/NY-series Controller
1
(2) Ethernet direct connection (when executing an FH project)
Sysmac Studio
USB/Ethernet
EtherCAT
FH
Project data that
the Sysmac Studio
manages
There are two types of data: the data that the
NJ/NX/NY-series Controller manages and
the data that the FH sensor controller
manages.
FH
Ethernet
There is the data that the FH sensor
controller manages.
Project data
Project data
Data that the NJ/NX/NY-series
Controller manages
Configurations and Setup
CPU/Expansion
EtherCAT
Racks
Controller Setup
I/O Map
Motion Control Cam Data
Settings
Setup
Event Setup
Task Setup
Data that the FH sensor
controller manages
Scene group
data
System data
Data that the FH sensor
controller manages
Scene group
data
System data
Tool data
Tool data
Configurations and Setup
POUs
Data
Tasks
Data to be
synchronized with
Sysmac Studio
Available functions
in Sysmac Studio
that control the FH
sensor controller
online
The data that the NJ/NX/NY-series Controller
manages within the project data that Sysmac
Studio manages is synchronized.
Because the data that the FH sensor
controller manages (i.e., the settings data for
the FH sensor controller) is not synchronized,
the settings for the FH sensor controller need
to be synchronized separately.
Refer to 2-8 Precautions on Synchronization
through an NJ/NX/NY-series Controller on
page 2-39
Checking the data output from the FH sensor
controller sent through EtherCAT is possible.
Making setting changes, and creating and
adjusting the measurement flows for the FH
are not possible.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
The data that the FH sensor controller
manages (i.e., the settings data for the FH
sensor controller) within the project data that
Sysmac Studio manages is synchronized.
Refer to 3-3 Synchronizing Project Data and
Sensor Setting Data on page 3-8
Making setting changes on the FH sensor
controller, creating and adjusting the
measurement flows for the FH in addition to
checking the output data from the FH sensor
controller are all possible.
1-5
1-2-2 Project Data Handling in Different System Configurations
(1) Connection through an NJ/NX/NY-series
Controller (when executing
an NJ/NX/NY project)
1-2 Project Management
1-2-2
1 Overview
Available functions
in Sysmac Studio
that control the FH
sensor controller
offline
Downloading the
settings data for
the FH sensor
controller
(1) Connection through an NJ/NX/NY-series
Controller (when executing
an NJ/NX/NY project)
Checking the data output from the FH sensor
controller and sent through EtherCAT is
possible.
Making setting changes, and creating and
adjusting the measurement flows for the FH
besides checking the output data from the
FH sensor controller are all possible.
The settings data for the FH sensor controller
is not downloaded.
Performing the data downloading from
Sysmac Studio will not download the data
that the FH sensor controller manages within
the project data that Sysmac Studio
manages. Therefore, the settings for the FH
sensor controller will not be overwritten.
There are following two methods to download
the FH settings data to the FH sensor
controller.
• Directly connecting to the FH sensor controller and downloading the data
Uploading the
settings data for
the FH sensor
controller
• Extracting the data from Sysmac Studio
and loading it to the FH sensor controller
via the external memory.
The settings data for the FH sensor controller
is not uploaded.
After performing the data uploading to
Sysmac Studio, all the FH settings data
values (i.e., the scene group data, the
system data, the communications command
macros, and the security settings data) that
the FH sensor controller manages within the
project data that Sysmac Studio manages will
be reset to the factory defaults.
The device variables related to the FH
sensor controller in the I/O Map are
uploaded.
There are following two methods to transfer
the settings data for the FH sensor controller
to Sysmac Studio.
(2) Ethernet direct connection (when executing an FH project)
Making setting changes, creating and
adjusting the measurement flows for the FH
besides checking the output data from the
FH sensor controller are possible.
Downloading the FH settings data from
Sysmac Studio is possible.
If the FH sensor controller is connected to
the computer that runs Sysmac Studio via
Ethernet, downloading the FH settings data
from Sysmac Studio to the FH sensor
controller is possible by transferring the
project data that the Sysmac Studio
manages to the FH sensor controller via the
Ethernet.
If not connected, right-click the FH sensor
controller in the Multiview Explorer and
select [Save file] from the menu to save the
data in the external memory.
Then, load the data in the external memory
to the FH sensor controller.
Uploading the settings data for the FH
sensor controller to Sysmac Studio is
possible.
If the FH sensor controller is connected to
the computer that runs Sysmac Studio via
Ethernet, loading the data in the FH sensor
controller to Sysmac Studio project is
possible by transferring the FH settings data
to the project via Ethernet.
If not connected, connect the external
memory that holds the FH settings data to
the computer that runs Sysmac Studio.
Then, right-click the FH sensor controller in
the Multiview Explorer and select [Load from
file] from the menu to load the data.
• Directly connecting to the FH sensor controller and uploading the data
• Save the settings data in the FH sensor
controller in the external memory and load
it to Sysmac Studio via the external memory.
1-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1 Overview
The data that the NJ/NX/NY-series Controller manages and the data that the FH sensor controller manages are handled separately on Sysmac Studio except for the I/O Map data that the
NJ/NX/NY-series Controller manages. The I/O Map is associated to the system data that the
FH sensor controller manages. Because of this, the information in the I/O Map will be updated
and changed after editing the data that the FH sensor controller manages (i.e., the settings
data for the FH sensor controller).
1-2 Project Management
Precautions for Correct Use
1
Project data
Configurations and Setup
EtherCAT
Controller Setup
Data that the FH sensor controller
manages
1-2-2 Project Data Handling in Different System Configurations
Data that the NJ/NX/NY-series Controller manages
CPU/Expansion Racks
I/O Map
Motion Control Setup
Cam Data Settings
Event Setup
Task Setup
Scene group data
System data
Tool data
Configurations and
Setup
Data
Tasks
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
1-7
1 Overview
1-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2
Basic Operations
This chapter describes the basic design flow and design items for using Sysmac Studio.
2-1 Basic Design Flow 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2-2 Basic Design Flow 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2-3 Creating a New Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-3-1
2-3-2
2-3-3
Creating a New Project File from the Project Window . . . . . . . . . . . . . . . . . . . 2-6
Adding FH Device to a Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Deleting FH Device from a Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2-4 Description of Screen Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2-4-1
2-4-2
2-4-3
2-4-4
2-4-5
2-4-6
Application Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Multiview Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Edit Pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Toolbox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
2-5 Basic Operations of Scene Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25
2-5-1
2-5-2
2-5-3
2-5-4
2-5-5
2-5-6
2-5-7
Switching Scenes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Managing Scenes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Entering Scene Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Searching for a Scene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switching Scene Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Managing Scene Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Entering Scene Group Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-26
2-26
2-27
2-27
2-27
2-28
2-29
2-6 Basic Operations of Flow Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
2-6-1
2-6-2
2-6-3
Adding a Processing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Managing Processing Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
Searching for a Processing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
2-7 Function List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
2-7-1
2-7-2
List of Functions Provided with the FH Tool . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35
Comparison with FH Series Unit Functions . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38
2-8 Precautions on Synchronization through an NJ/NX/NY-series
Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
2-8-1
2-8-2
2-8-3
2-8-4
Synchronized Project Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving and Loading the Settings Data for the FH Sensor Controller . . . . . . .
Transferring Data from the Sysmac Studio . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transferring Data to the Sysmac Studio . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-40
2-41
2-42
2-44
2-1
2 Basic Operations
Precautions for Correct Use
• The data being synchronized varies depending on the connection method (i.e., Ethernet
direct connection or connection through an NJ/NX/NY-series Controller) between the FH sensor controller and the computer that runs Sysmac Studio.
• For information on connection through an NJ/NX/NY-series Controller, refer to 2-8 Precautions on Synchronization through an NJ/NX/NY-series Controller on page 2-39
2-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-1
Basic Design Flow 1
For details on the program on the NJ/NX/NY-series CPU Unit side, task design, and debugging, refer to
Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
 New project settings
Create a project file.
1
Starting Sysmac Studio
2
Start Sysmac Studio.
Refer to 3-3-1 Starting and Exiting the Sysmac Studio in Sysmac Studio Version 1 Operation
Manual (Cat. No. W504-E1-08 or later).
2
Designing a new project
Create a new project.
Refer to 3-3-2 Creating a Project File in Sysmac Studio Version 1 Operation Manual (Cat. No.
W504-E1-08 or later).
 Controller configuration and settings
• Controller configuration
(1) Creating an EtherCAT configuration
Register FH as an EtherCAT slave in [EtherCAT].
Refer to 5-1 EtherCAT Configuration and Settings in Sysmac Studio Version 1 Operation
Manual (Cat. No. W504-E1-08 or later).
(2) Registering device variables
When using or using after editing device variables for the user defined variables to connect
the FH I/O information and program, register the device variables in [I/O Map].
Refer to 4-1-2 Creating Device Variables in Sysmac Studio Version 1 Operation Manual
(Cat. No. W504-E1-08 or later).
• Controller settings
(1) Editing slave parameters
Edit the Operation Settings of the slaves.
Refer to 5-2-1 Creating the EtherCAT Slave Terminal Configuration in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
 Sensor connection
Establish an online connection with the sensor.
(1) Connecting a sensor
Refer to Section 3 Connecting with a Vision Sensor
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-1 Basic Design Flow 1
This section describes the flow for designing a system that uses NJ/NX/NY-series CPU Unit as a controller.
2-3
2 Basic Operations
 Design
Create the processing flow.
(1) Creating flow
Refer to 2-6 Basic Operations of Flow Editing on page 2-30
(2) Editing processing units
Refer to 4-2 Editing a Processing Unit on page 4-4
 Online debugging of sensor
Perform debugging using the actual device.
(1) Performing test measurement
Perform test measurement on sample work. Adjust the parameters if necessary.
Refer to Section 6 Online Debugging
Precautions for Correct Use
The settings data for the FH sensor controller cannot be synchronized with the data in the Sysmac Studio project via an NJ/NX/NY-series Controller.
Refer to 2-8 Precautions on Synchronization through an NJ/NX/NY-series Controller on page 2-39
To synchronize them, directly connect the FH sensor controller to the computer that runs Sysmac Studio via Ethernet.
Refer to 3-3 Synchronizing Project Data and Sensor Setting Data on page 3-8
2-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-2
Basic Design Flow 2
 New project settings
Create a project file.
(1) Starting Sysmac Studio
Start Sysmac Studio.
Refer to 3-3-1 Starting and Exiting the Sysmac Studio in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
(2) Designing a new project
Create a new project.
Select a vision sensor for the category and FH for the device.
Refer to 2-3 Creating a New Project on page 2-6
(3) Selecting sensor type
Select the sensor type and then establish an online connection.
Refer to step 3 on P. 2-7 of 2-3-1 Creating a New Project File from the Project Window on
page 2-6
 Sensor configuration and settings
• Sensor configuration
(1) Creating an interface configuration for the sensor
Edit the interface configuration.
Refer to 5-1 Setting Procedure on page 5-3
• Sensor settings
(1) Editing the communication conditions
Edit the communication conditions of the sensor.
Refer to 5-1 Setting Procedure on page 5-3
 Design
Create the processing flow.
(1) Creating flow
Refer to 2-6 Basic Operations of Flow Editing on page 2-30
(2) Editing processing units
Refer to 4-2 Editing a Processing Unit on page 4-4
 Online debugging
Perform debugging using the actual device.
(1) Performing test measurement
Perform test measurement on sample work. Adjust the parameters if necessary.
Refer to Section 6 Online Debugging
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-5
2-2 Basic Design Flow 2
This section describes the flow for designing a system that uses a controller other than NJ/NX/NY-series
CPU Unit.
2
2 Basic Operations
2-3
Creating a New Project
This section describes how to create a new project file. For details on the basic operations, refer to 3-3
Creating a Project in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
Here, we describe how to create a new project for the FH vision sensor (hereinafter referred to as "FH
project").
2-3-1
Creating a New Project File from the Project Window
1
2
Click the [New Project] button in the project window.
In the [Project Properties] dialog box, enter the information in [Project name], [Author] (optional),
and [Comment] (optional), select the following device from [Category] and [Device] of [Select
Device], and click the [Create] button.
Item
Category
Device
2-6
Setting
Vision sensor
FH
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
3
Select the FH vision sensor to connect to.
If you know the IP address of the sensor you wish to connect to beforehand or will connect to a
sensor via a router, select the [Specify the IP address] check box and then enter the IP address
in [IP address]. After input is complete, click the [OK] button.
If you wish to edit the settings offline, click [Enter the type], select the [Type] and [Version] items
for the sensor you wish to edit, and then click the [OK] button.
2-3 Creating a New Project
When establishing an online connection, click [Search for sensors] and then click the [Search]
button. The found sensors are displayed in a list. Select the sensor you wish to connect to and
then click the [OK] button.
2
2-3-1 Creating a New Project File from the Project Window
4
A new project is created.
The project file is created and the next screen appears.
Precautions for Correct Use
• An online connection cannot be established if the FH device registered to the project and the
actual device are not the same type and version.
• If there is already a different FH slave device in the project with an established online connection, you will not be able to establish an online connection for a new FH slave device.
To establish an online connection for a new FH slave device, switch the other FH slave
device from online to offline.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-7
2 Basic Operations
2-3-2
Adding FH Device to a Project
You can add an FH device to a project.
Right-click the Device Group and select [Add | FH].
The sensor selection screen appears. Select the sensor type.
The selected FH device is registered.
Precautions for Correct Use
Up to eight FH devices can be added to a single project.
If more than eight FH devices are registered to a project, "
invalid FH devices.
2-3-3
" appears in the type field of the
Deleting FH Device from a Project
You can delete FH device from a project.
Right-click the FH vision sensor you wish to delete and select [Delete].
2-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Description of Screen Components
This section describes the screen components in FH project.
For a description of the screen components in NJ/NX/NY-series CPU Unit project, refer to 3-4 Parts of
the Window in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
2-4-1
Application Window
2-4 Description of Screen Components
2-4
2
1)
2)
2-4-1 Application Window
3)
4)
No.
1
2
3
4
5
5)
Name
Menu Bar
Toolbar
Multiview Explorer
Edit Pane
Toolbox
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-9
2 Basic Operations
2-4-2
Menu Bar
File
Edit
View
Insert
Tools
Menu Name
Close
Save
Save As
Save As New Number
Import
Export
Exit
Copy
Paste
Delete
Multiview Explorer
Toolbox
Reset Window Layout
Controller
Displacement Sensor
Vision Sensor
Options
Help Contents
Help
2-4-3
Online Registration
Keyboard Mapping Reference
About Sysmac Studio
Description
Closes the project.
Saves the project.
Saves the project with a different name.
Saves the project with a new update number.
Imports an exported file so that it can be edited in the tool.
Saves the project as an external file.
Closes Sysmac Studio.
Copies the selected item.
Pastes the copied item.
Deletes the selected item.
Displays the Multiview Explorer.
Displays the Toolbox.
Resets the window layout.
Inserts an NJ or NX project.
Inserts a ZW project.
Inserts an FQ-M or FH project.
Displays the Options menu.
Displays “Vision System FH Series Operation Manual Sysmac Studio (Cat. No. Z343)."
Performs online registration.
Displays the shortcut key reference.
Displays the version of Sysmac Studio.
Toolbar
Button Name
Copy
Paste
Delete
Help
2-4-4
Description
Copies the selected item.
Pastes the copied item.
Deletes the selected item.
Displays Vision System FH Series Operation Manual Sysmac Studio
(Cat. No. Z343)
Multiview Explorer
• This pane will be the access point for all data of the FH series.
• You can right-click any data item that can be set and select an item from the menu (context menu).
You can also display various editing screens in the Edit Pane.
• Multiview Explorer can be displayed or hidden by clicking the display/hide bar on the left side of the
window. Even when hidden, it can be displayed temporarily by placing the mouse pointer over the
display/hide bar. Moving the mouse pointer away from the bar returns the Multiview Explorer to the
hidden state.
2 - 10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Tree View Items
Device Group
Type
Menu Item
Add | FH
Rename
Edit
Delete
Restart
Online
Offline
Stop offline
editor
Change Version
(X=0,1,,,7)
Scene data
System data
Edit
Edit
Saves the sensor settings data to non-volatile memory.
Copies setting data of the line.
Pastes the copied setting data of the line.
Changes the line name.
Saves scene group 0 + system data to a file.
Loads scene group 0 + system data from a file.
Displays the print settings parameters in the Edit Pane.
Displays the scene data editing screen in the Edit Pane.
Copies the scene group data.
Pastes the scene group data.
Deletes the scene group data.
Saves the scene group data to a file.
Loads the scene group data from a file.
Displays the system data editing screen in the Edit Pane.
Copies the system data.
Pastes the system data.
Deletes the system data.
Saves the system data to a file.
Loads the system data from a file.
Displays the communication command macro tool in
the Edit Pane.
Copies the communication command macro data.
Pastes the communication command macro data.
Deletes the communication command macro data.
Saves the communication command macro data to a file.
Loads the communication command macro data from a file.
Displays the calibration support tool in the Edit Pane.
Displays the user data tool in the Edit Pane.
Displays the file saving tool in the Edit Pane.
Displays the Conveyor Panorama Display tool in the
Edit Pane.
Displays the image file save tool in the Edit Pane.
Displays the scene macro tool in the Edit Pane.
Displays the Conveyor Calibration Wizard tool in the
Edit Pane.
Displays the setting tool for the scene group saving
destination in the Edit Pane.
Displays the Calibration Plate Print tool in the Edit Pane.
Displays the security setting tool in the Edit Pane.
Edit
Displays the registered image manager in the Edit Pane.
Edit
Displays the update standard position tool in the Edit Pane.
Edit
Displays the conversion scene group data tool in the Edit Pane.
Edit
Communication Command Macro
Tools
Calibration Support Tool
User Data
Save file
Conveyor Panorama
Display
Image file save
Scene Control macro tool
Conveyor Calibration
Wizard
Scene Group Saving
Destination Settings
Calibration Plate Print
Security settings
Registered image
Manager
Update standard position tool
Conversion scene
group data tool
Displays the Scene maintenance window in the Edit Pane.
Copy
Paste
Delete
Save to file
Load from file
Edit
Edit
Edit
Edit
Edit
Edit
Edit
Edit
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 11
2
2-4-4 Multiview Explorer
Line X
Monitor window
Scene maintenance window
Save data
Copy
Paste
Rename
Save to file
Load from file
Print
Edit
Copy
Paste
Delete
Save to file
Load from file
Edit
Copy
Paste
Delete
Save to File
Load from File
Description
Adds a sensor to the project.
Changes the device group name.
Displays the main screen in the Edit Pane.
Deletes the sensor from the project.
Restarts the sensor.
Switches the connection state with the sensor to online.
Switches the connection state with the sensor to offline.
Ends the offline editor.
Ends the following application.
• FZ-CoreRA<current_line_number_0_to_7>.exe
Changes the sensor version. When the version is
changed, the setting data is initialized.
This menu item only appears in NJ/NX/NY Project.
Displays the monitor window in the Edit Pane.
2-4 Description of Screen Components
Item list that make up the Multiview Explorer and the menu items displayed by right-clicking
2 Basic Operations
Precautions for Correct Use
The displayed line number changes according to the operation mode. In the Multi-line Random
Trigger operation mode, the set number of lines are displayed. In the Non-stop Adjustment
operation mode, line 0 and 1 are displayed. For details on the operation mode, refer to Vision
System FH/FZ5 Series User's Manual (Cat. No. Z365).
2-4-5
Edit Pane
This pane is for displaying and editing the detailed data of all items.
The following screens are provided.
Screen
Description
This allows you to access the sensor information, the connecSensor connection screen
tion with the sensor, the main screen of each line, etc.
Monitor window
This allows you to check the measurement results.
This allows you to switch scenes or scene groups, and copy or
delete a scene and a scene group.
Scene maintenance window
It also allows you to perform test measurement and check the
measurement results.
Scene data editing screen This allows you to set the scene data.
System data editing screen This allows you to set the system data.
Communication command This allows you to set the communication command macro.
macro screen
User Data tool screen
This allows you to edit the user data.
This allows you to copy or move files between the RAMDisk/external memory of the FH vision sensor or between the
RAMDisk/external memory and a computer. It also allows you to
File Save Tool screen
save the logging image stored in the vision sensor memory to
the RAMDisk or external memory of the sensor, or to a computer.
Calibration support tool screen This allows you to check the calibration settings.
With this tool, it is possible to restrict access to FH Vision Image
Security settings
Sensor to specific users and user groups.
Scene Group Saving Des- With this tool, it is possible to set the storage location of scene
tination Settings
group data.
With this tool, it is possible to save logged images and image
Image file save
files that are saved in the Image Sensor to a RAM disk or external memory device in FH Vision Sensor, or to a computer.
With this tool, it is possible to save images used for model registration
Registered image Manager and reference registration as registration images. The saved images
can be used for re-registration and adjustment of reference positions.
Update standard position
With this tool, it is possible to set or change the reference position for
tool
more than one processing unit that is specified in the measurement flow.
Conversion scene group
With this tool, it is possible to create a scene group that has
data tool
more than or equal to 129 scenes.
With this tool, it is possible to supplement and expand measureScene Control macro tool
ment flow and scene control.
This tool is used for conveyor tracking applications. To adjust the
trigger interval and conveyor speed for additional lines or new
Conveyor Panorama Display product types, this tool combines images to create a panoramic
image, and then displays the region of captured image and the
registered region of the model of the target objects over it.
This tool is used for conveyor tracking applications to reciproConveyor Calibration Wizard cally convert different coordinates for image sensor, conveyor,
and robots by giving instructions in a wizard-style.
This tool is used for conveyor tracking applications to print CaliCalibration Plate Print
bration Pattern.
Reference Page
P. 2-13
P. 2-14
P. 2-18
P. 2-20
P. 2-22
―
―
P. 8-4
P. 8-3
*1
*1
*1
*1. This function is applicable to the Conveyor Tracking Calibration Application.
For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
2 - 12
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-4 Description of Screen Components
Sensor connection screen
2
Group
Sensor
information
Online
Item
Sensor name
Comment
Type
Version
Available application memory
IP address
Connect
Disconnect
Search for sensors
Sensor Restart
Initialize
Description
Allows you to change the sensor name.
Allows you to enter a comment for the sensor.
Displays the sensor type information.
Displays the sensor version information.
Displays the amount of available application memory.
Sets the IP address of the sensor for online connections.
Establishes an online connection to the sensor with the specified IP address.
Disconnects the sensor currently connected with an online connection.
Searches for sensors within the same network.
Restarts the sensor.
Initializes the sensor.
Additional Information
• For details on the settings in the sensor connection screen, refer to 3-2 Establishing an
Online Connection with a Vision Sensor on page 3-4.
• If there is already a different FH slave device in the project with an established online connection, you will not be able to establish an online connection for a new FH slave device.
First, switch the other FH slave device from online to offline.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 13
2-4-5 Edit Pane
This allows you to access the sensor information, the connection with the sensor, the main screen of
each line, etc.
2 Basic Operations
Monitor window
1)
2)
4)
5)
6)
3)
This allows you to check the measurement results.
No.
Screen Component
1
Status display area
2
4
5
Image display area
Image size control
section
Flow
Detail result
6
Image display settings
3
Reference
Page
Description
Allows you to access the sensor information, the connection with
the sensor, the main screen of each line, etc.
Allows you to check the measurement results.
P. 2-14
P. 2-15
Enlarges or reduces the selected image.
P. 2-15
Displays the processing flow for the relevant line or current scene.
Displays the results for the processing unit selected in the flow.
Sets the displays settings for images displayed in the image display
area.
P. 2-16
P. 2-17
P. 2-17
 Status display area
2)
3)
4)
5)
1)
6)
2 - 14
No.
1
2
Item
Judgment result
Processing time
3
Sensor name and IP
address
4
5
6
Line name
Scene group name
Scene name
Description
Displays the judgment result (OK or NG).
Displays the processing time for the most recent measurement process.
Displays the sensor name and IP address.
When the sensor is offline, "Offline" is displayed instead of the IP address.
Displays the line for which information is currently being displayed.
Displays the current scene group number and scene group name.
Displays the current scene number and scene name.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-4 Description of Screen Components
 Image display area
2
The settings for image display in the image display area can be changed in the Image display settings menu. For details on the Image display settings menu, refer to Image display settings on page
2-17.
While an image is displayed enlarged, you can change the display area by left-clicking and dragging
the displayed image.
 Image size control section
This allows you to enlarge or reduce the selected image.
Button
Description
Enlarges the image. Image display is enlarged in 20% steps. (Upper limit: 1600%)
Reduces the image. Image display is reduced in 20% steps. (Lower limit: 1%)
Makes the image fit the display frame.
Enlarges or reduces the image.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 15
2-4-5 Edit Pane
This displays the image and measurement result (graphic) for the processing unit selected in the
flow display.
2 Basic Operations
 Flow
This displays the processing flow for the relevant line or current scene.
If a processing unit displayed in the list is selected, the following display information is linked and so
changes accordingly.
• Image display information
• Detailed result display information
If multiple images are displayed, the display information of the image with the focus on it changes.
If a processing unit is searched in the search area, the focus moves to the found processing unit.
Item
Search
Flow list
Description
Searches for the specified processing unit from within the processing flow.
Displays the processing flow for the relevant line or current scene.
With this tool, it is possible to select a processing unit to be used for measurement. The measurements whose processing units with the checkmark removed will not be performed.
Check [Enable Simplified Non-stop Adjustment] to adjust the judgement conditions for each processing unit.
The judgement condition editing pane Opens by the following methods:
• Select [Edit] from the context menu of the relevant processing unit within the measurement flow
• Click the icon of the relevant processing unit
2 - 16
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-4 Description of Screen Components
 Detail result
This displays the results for the processing unit selected in the flow.
2
 Image display settings
2-4-5 Edit Pane
Item
Image layout
Image mode
Positions
Sub image
Description
Selects the number of images to display.
Selection items: 1Form, 2Form, and 4Form
Selects the image mode for the image with the focus on it.
Selection items: Through, Freeze, and NG image
Selects position list display for the image with the focus on it.
Selection items: OFF and ON
Selects the sub image number for the image with the focus on it.
Available sub-image numbers vary depending on the processing item.
Select items: Image0, Image1,..., image31
This sets the displays settings for images displayed in the image display area.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 17
2 Basic Operations
Scene maintenance window
This allows you to copy, switch, and clear scene data and scene group data.
It also allows you to perform test measurement and check the measurement results.
 Status display area
This is the same as in the monitor window. Refer to Status display area on page 2-14.
 Image display area
This is the same as in the monitor window. Refer to Image display area on page 2-15.
 File selection section
Button
Description
Displays camera images. Selection is not possible when offline.
Displays logging images. Selection is not possible when offline.
Displays file images.
When online, displays images in the RAMDisk or external memory, i.e. USB memory.
When off-line, displays images in the following folder on the computer.
C:\Documents and Settings\<User name>\My Documents\OMRON FH
Launch the File Explorer and select an image file.
2 - 18
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Button
Description
Performs continuous measurement of images.
In the case of camera images, continuously measures and displays camera images.
In the case of logging images, continuously measures and displays images in the
logging folder.
In the case of file images, continuously measures and displays images in the folder.
When logging images and file images are selected, continuous measurement is
stopped after all images are measured.
2-4 Description of Screen Components
 Image control section
2
Stops continuous measurement.
2-4-5 Edit Pane
Measures and displays the previous image.
Measures and displays the next image.
Saves the latest image in a file.
 Image size control section
This is the same as in the monitor window. Refer to Image size control section on page 2-15.
 Data save
This saves the settings data to non-volatile memory of the FH sensor.
 Measure
Performs a single measurement.
The measurement process is performed for the image that is currently displayed.
 Test measurement settings
Item
Output
Description
Outputs the measurement results to an external device when test measurement is
performed.
 Flow
This is the same as in the monitor window. Refer to Flow on page 2-16.
 Detail result
This is the same as in the monitor window. Refer to Detail result on page 2-17.
 Image display settings
This is the same as in the monitor window. Refer to Image display settings on page 2-17.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 19
2 Basic Operations
 Scene maintenance area
Clicking the scene maintenance item bar opens the scene maintenance window.
This screen allows you to manage and switch the scene group data and scene data.
For details on the specifications, refer to 2-5 Basic Operations of Scene Data on page 2-25.
Scene data editing screen
This editing screen allows you to build the processing unit flow.
A new processing unit can be added to the flow by dragging and dropping any processing unit in the
Toolbox on to the list.
It is also possible to check the image that is the measurement target, and the measurement results
for each processing unit.
2 - 20
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-4 Description of Screen Components
 Flow display
2
Each editing process (adding, copying, deleting, etc.) of the processing units in the flow can be performed.
Item
Search
Flow list
Description
Searches for the specified processing unit from within the processing flow.
Displays the processing flow for the relevant line or current scene.
The registered processing units are displayed in the flow list.
With this tool, it is possible to select a processing unit to be used for measurement.
The measurements whose processing units with the checkmark removed will not be performed.
 Data save
This is the same as in the Scene maintenance screen. Refer to Data save on page 2-19.
 Transfer data
This transfers the settings for line 0 to line 1.
The button is displayed only when the operation mode is in Non-stop Adjustment Mode.
 Non-stop data transfer
This transfers the settings for line 1 to line 0.
The button is displayed only when the operation mode is in Non-stop Adjustment Mode.
For details on “Transfer data” and “Non-stop data transfer”, refer to Setting the Operation Mode Non-stop Adjustment Mode in Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
 Measure
This is the same as in the Scene maintenance screen. Refer to Measure on page 2-19.
 File selection section
This is the same as in the Scene maintenance screen. Refer to File selection section on page 2-18.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 21
2-4-5 Edit Pane
This displays the processing flow for the relevant line or current scene.
2 Basic Operations
 Image control section
This is the same as in the Scene maintenance screen. Refer to Image control section on page 2-19.
 Detail result
This is the same as in the monitor window. Refer to Detail result on page 2-17.
System data editing screen
2)
1)
3)
This editing screen allows you to set the system data.
System data is managed on a group basis and the editing items for each group are displayed by clicking the corresponding icon.
No.
1
2
3
Name
Icon
Group name display area
Editing item display area
For details on each group, refer to 8-5 Changing the System Environment on page 8-8.
2 - 22
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-4 Description of Screen Components
Tool settings editing screen
The tool settings editing screen displays the editing screens of the following tools.
For details on each tool, refer to Section 8 Other Useful Functions.
2
2-4-5 Edit Pane
Tool
Communication command macro
Calibration support tool
User data tool
File save tool
Conveyor Panorama Display
Image file save
Scene Control macro tool
Conveyor Calibration Wizard
Functional Overview
Edits communication command macros.
Allows you to check the calibration settings.
Allows you to edit the user data, set the initial settings, and enter a comment that
describes the data.
Saves the image data to a file.
This tool is used to display a panoramic composition of workpieces being carried by conveyor. *1
With this tool, it is possible to save logged images and image files that are saved in the Image
Sensor to a RAM disk or external memory device in FH Vision Sensor, or to a computer.
With this tool, it is possible to supplement and expand measurement flow and scene control.
This tool is used for conveyor tracking applications to reciprocally convert different coordinates for image sensor, conveyor, and robots by giving instructions in a wizard-style. *1
Scene Group Saving DesWith this tool, it is possible to set the storage location of scene group data.
tination Settings
Calibration Plate Print
Security settings
Registered image Manager
Update standard position
tool
Conversion scene group
data tool
During calibration, it can be used to print the calibration pattern of a calibration plate. *1
With this tool, it is possible to restrict access to FH Vision Image Sensor to specific
users and user groups.
With this tool, it is possible to save images used for model registration and reference
registration as registration images. The saved images can be used for re-registration and adjustment of reference positions.
With this tool, it is possible to set or change the reference position for more than one
processing unit that is specified in the measurement flow.
With this tool, it is possible to create a scene group that has more than or equal to 129 scenes.
*1. This function is applicable to the Conveyor Tracking Calibration Application.
For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 23
2 Basic Operations
2-4-6
Toolbox
The Toolbox displays a list of the processing units that can be used.
When the scene editing screen is displayed in the Edit Pane, you can add a processing unit by selecting any processing unit and dragging and dropping it onto the flow list in the scene editing screen.
1)
2)
3)
No.
1
2
3
2 - 24
Item
Processing item search window
Processing item area
Guidance
Operation
Searches for processing items.
Displays the available processing units.
Displays an overview of the selected processing unit.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Basic Operations of Scene Data
An FH vision sensor can handle multiple scene data.
You can perform operations such as switching, copying, and deleting scenes with the scene maintenance functions in the scene maintenance window.
Right-click [Line X] in the Multiview Explorer and select [Scene maintenance screen] from the menu.
2-5 Basic Operations of Scene Data
2-5
Click [Scene maintenance] and show [Scene maintenance] Pane.
2
Additional Information
Project data that was edited offline can be transferred to the FH vision sensor.
For details on how to transfer project data, refer to 3-3 Synchronizing Project Data and Sensor
Setting Data on page 3-8.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 25
2 Basic Operations
2-5-1
Switching Scenes
You can switch scenes by selecting the target scene in the scene list and then clicking the [Switch] button.
When scene switching is performed, the scene data editing screen is closed automatically if it is open in
the Edit Pane.
2-5-2
Managing Scenes
Right-clicking a target scene in the scene list displays the following menu.
Select the menu item for the operation you wish to perform.
Item
Copy
Paste
Delete
Save to file
Load from file
2 - 26
Description
Copies the selected scene.
Pastes the copied scene.
Clears the selected scene.
Saves the selected scene as a scene data file to the folder on the computer.
The save file format can be selected from either binary scene data (file extension:
SCN), or CSV. Select CSV to output a list of settings with the “Set/Get” attribute to the
saved file. (Settings with the “Set only” and “Get only” attribute cannot be output.) The
function to output CSV files outputting by selecting “Save to file” and the “Settings
download and upload tools” function for the FH vision sensor are the same. For details,
refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
Loads the Scene data file stored in computer folder.
A Scene data file in CSV format also can be loaded.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-5 Basic Operations of Scene Data
2-5-3
Entering Scene Information
The scene list displays the following information.
2
Description
Displays the scene name. (Maximum of 15 characters)
Displays the author name. (Maximum of 15 characters)
Displays the comment. (Maximum of 255 characters)
Each item in the list can be directly edited.
2-5-4
Searching for a Scene
You can search for a scene in the list by entering any scene name in the search box and then clicking
the search button (
2-5-5
). Clicking the search clear button (
) clears the search results.
Switching Scene Groups
Clicking the scene group editing button displays the scene group editing window.
You can switch scene groups by selecting the target scene group in the list and then clicking the
[Switch] button.
When scene switching is performed, the scene data editing screen is closed automatically if it is open in
the Edit Pane.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 27
2-5-3 Entering Scene Information
Item
Scene Name
Author
Comment
2 Basic Operations
2-5-6
Managing Scene Groups
Right-clicking a target scene group in the scene group list in the scene group editing window displays
the following menu.
Select the menu item for the operation you wish to perform.
Item
Copy
Paste
Delete
Save to file
Load from file
2 - 28
Description
Copies the selected scene group.
Pastes the copied scene group.
Clears the selected scene group.
Selected Scene group is saved the following folder on the computer.
C:\Documents and Settings\<User name>\My Documents\OMRON FH
Scene group data file is saved the following folder on the computer.
C:\Documents and Settings\<User name>\My Documents\OMRON FH
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-5 Basic Operations of Scene Data
2-5-7
Entering Scene Group Information
The scene group list displays the following information.
Item
Scene group Name
Description
Displays the scene group name.
The current scene group name can be edited.
2
2-5-7 Entering Scene Group Information
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 29
2 Basic Operations
2-6
Basic Operations of Flow Editing
This section describes how to edit the flow.
Edit the flow in the scene data editing screen. For details on the scene data editing screen, refer to
Scene data editing screen on page 2-20.
You can open the scene data editing screen in the Edit pane by double-clicking scene data, or by
right-clicking it and selecting [Edit] from the menu.
2 - 30
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Adding a Processing Unit
When you wish to add a new processing unit to the flow, first select any processing unit from the Toolbox.
Then drag the selected processing unit to the place you wish to insert it in the flow list.
2-6 Basic Operations of Flow Editing
2-6-1
2
2-6-1 Adding a Processing Unit
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 31
2 Basic Operations
2-6-2
Managing Processing Units
Right-clicking a target processing unit in the flow list displays the following menu.
Select the menu item for the operation you wish to perform.
Item
Description
Edit*1
Opens the processing unit editing screen.
Rename
New folder
Copy
Paste
Delete
Changes the name of the processing unit.
Inserts a folder unit.
Copies the selected processing unit.
Pastes the copied processing unit.
Clears the selected processing unit.
Saves the setting data of processing units to the specified file.
When on-line, saves the selected Scene group as a file to the RAMDisk or the external
memory, i.e. USB memory. When off-line, saves it to the described following folder on
the computer.
Save to file
C:\Documents and Settings\<User name>\My Documents\OMRON FH
Loads the setting data of processing units from the specified file.
Load from file
When on-line, loads a Scene data file in the RAMDisk or the external memory, i.e. USB
memory from the selected Scene group. When off-line, loads the Scene data file in the
described following folder on the computer.
C:\Documents and Settings\<User name>\My Documents\OMRON FH
*1. If the processing item is not supported in the edit operation, the following message appears.
"The ProcItem has not been supported."
Menu buttons
Button
Description
Copies the processing unit with the focus on it.
Pastes the copied processing unit.
Deletes the processing unit with the focus on it.
2 - 32
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-6 Basic Operations of Flow Editing
Display is hierarchical in the flow list when the following processing units are used.
• Folder unit
• Parallelize unit
• Parallelize task unit
<No folder unit>
2
2-6-2 Managing Processing Units
<Folder unit layer 1>
<Folder unit layer 2>
<Parallelize unit>
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 33
2 Basic Operations
2-6-3
Searching for a Processing Unit
You can search for a processing unit in the flow list by entering any processing unit name in the search
box and then clicking the search button (
results.
2 - 34
). Clicking the search clear button (
) clears the search
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
2-7
List of Functions Provided with the FH Tool
The following shows the functions provided with the FH tool and the usage conditions.
○: Supported, x: Not supported
Classification
Item
Function
Edit
Project management
Menu Item
View
Insert
Tools
Help
Edit operations
Toolbar
Copy
Paste
Delete
Help
Device Group
Parameter
settings
Multiview
Type
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Add | FH
Rename
Edit
Change version
Delete
Restart
Online
Offline
End Offline Editor
When
Offline
Editing
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
x
x
○
○
○
○
○
x
○
○
x
○
x
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
x
○
2 - 35
2
2-7-1 List of Functions Provided with the FH Tool
File
Close
Save
Save As
Save As New Number
Import
Export
Exit
Copy
Paste
Delete
Multivew Explorer
Smart Project Search
Recently Closed Windows
Clear Recently Closed Windows
History
Toolbox
Reset Window Layout
Controller
Displacement Sensor
Vision Sensor
HMI
Slave Terminal
Option
Help Contents
About Sysmac Studio
When
Online
Editing
○
○
○
○
x
x
○
x
x
○
○
○
○
2-7 Function List
2-7-1
Function List
2 Basic Operations
Classification
Item
Line X
Parameter
settings
Multiview
Scene data
System data
Communication
Command Macro
Tools
2 - 36
Multiview
When
Online
Editing
○
○
○
x
x
○
○
○
○
○
x
x
○
○
○
○
○
○
○
x
x
x
○
○
When
Offline
Editing
○
○
x
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Edit
○
○
Edit
Edit
○
○
○
○
Edit
○
○
Edit
○
○
Edit
○
○
Edit
○
○
Edit
○
x
Edit
○
○
Edit
○
○
Edit
○
○
Edit
○
○
Edit
○
○
Function
Tools
Calibration Support Tool
User Data
Save file
Conveyor Panorama Display
Image file save
Scene Control
macro tool
Conveyor Calibration Wizard
Scene Group
Saving Destination Settings
Calibration Plate
Print
Security settings
Registered
image Manager
Update standard
position tool
Conversion
scene group data
tool
Monitor window
Scene maintenance window
Save data
Copy
Paste
Rename
Save to file
Load from file
Print
Edit
Copy
Paste
Delete
Save to file
Load from file
Edit
Save to file
Load from file
Edit
Copy
Paste
Delete
Save to file
Load from file
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Classification
Edit Pane
Function
Online measurement
Simulation*1
Camera images
File images
* File images in the vision sensor
Logging images
File images
* File images in the computer
Integrated simulation
When
Online
Editing
○
When
Offline
Editing
x
○
x
○
x
x
○
x
○
2-7 Function List
Measurement
control
Item
2
*1. Simulation is available only when editing an NJ/NX/NY Project.
2-7-1 List of Functions Provided with the FH Tool
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 37
2 Basic Operations
2-7-2
Comparison with FH Series Unit Functions
The following table shows the main differences between the functions provided with an FH series
device and the FH tool.
○: Supported, x: Not supported
Data management for a single FH vision sensor
Data management for all devices
Project management
Screen customization and screen layout control
Creating and displaying dedicated dialog boxes
Communications command macro
Save file
Calibration Support Tool
NG analyzer
User data
Security settings
Downloading and uploading setting values
Image file save
Registered Image Manager
Flow viewer
Update standard position tool
Tools
Conversion scene group data tool
Scene Group Saving Destination Settings
Scene Control macro tool
Custom dialog tool
Custom dialog
Configuration Copy
Line Maintenance
Sysmac
Studio
○
○
x
x
○
○
○
x
○
○
x
○
○
x
○
○
○
○
x
x
x
x
Conveyor Panorama Display
○*1
x
Conveyor Calibration Wizard
○*1
x
Calibration Plate Print
○*1
Single simulation
Integrated simulation
○
○
x
○
x
Classification
Simulation
Item
FH
○
x
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
*1. For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
2 - 38
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Precautions on Synchronization
through an NJ/NX/NY-series Controller
The contents of the Sysmac Studio project data and the data being synchronized vary depending on
the connection method (i.e., Ethernet direct connection or connection through an NJ/NX/NY-series
Controller) between the FH sensor controller and the computer that runs the Sysmac Studio. Particularly, the settings data for the FH sensor controller cannot be synchronized via an NJ/NX/NY-series
Controller.
This section describes precautions on performing the system synchronization from the System Studio
via an NJ/NX/NY-series Controller.
For the overview, refer to 1-2-2 Project Data Handling in Different System Configurations on page 1-5.
Sysmac Studio
NJ/NX/NY-series Controller
USB/Ethernet
Uploading
Downloading
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
EtherCAT
FH
2 - 39
2-8 Precautions on Synchronization
through an NJ/NX/NY-series Controller
2-8
2
2 Basic Operations
2-8-1
Synchronized Project Data
The Sysmac Studio manages the settings data for the FH sensor controller as a part of the project data.
(Refer to 1-2-1 Project data on page 1-4.)
The data size of the FH sensor controller settings varies depending on the created scenes and measurement flows. (Refer to Memory Usage Guidance For Processing Items in Vision System FH/FZ5
Series User's Manual (Cat. No. Z365).) Because of this, the settings data for the FH sensor controller
cannot be synchronized via an NJ/NX/NY-series Controller.
There are following methods to synchronize the settings data for the FH sensor controller with the data
in the Sysmac Studio.
(1) Directly connect the FH sensor controller to the computer that runs the Sysmac Studio via
Ethernet
Refer to 3-3 Synchronizing Project Data and Sensor Setting Data on page 3-8.
(2) Use the external memory
The procedures are described in the following sections:
2-8-2 Saving and Loading the Settings Data for the FH Sensor Controller on page 2-41
2-8-3 Transferring Data from the Sysmac Studio on page 2-42
2-8-4 Transferring Data to the Sysmac Studio on page 2-44
Sysmac Studio
NJ/NX/NY-series Controller
USB/Ethernet
EtherCAT
FH
(1) Ethernet
(2) USB memory/
SD memory card
2 - 40
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Saving and Loading the Settings Data for the FH Sensor Controller
This section describes procedures for saving and loading the settings data for the FH sensor controller
using the external memory.
 Saving and loading the settings data for the FH sensor controller
The following procedures describe how to save and load the settings data for the FH sensor controller that is in the FH sensor controller to the external memory. Save and load following four types of
the settings data individually.
(1) System + Scene group 0 data
Refer to the following:
2
• Saving Settings Data to the Controller RAM Disk or an External Memory Device in
Vision System FH/FZ5 Series User's Manual (Cat. No. Z365)
(2) Data for scene groups 1 to 31
Refer to the following:
• Saving Settings Data to the Controller RAM Disk or an External Memory Device in
Vision System FH/FZ5 Series User's Manual (Cat. No. Z365)
• Loading Settings Data from the Controller RAM Disk or an External Memory Device to
the Sensor Controller in Vision System FH/FZ5 Series User's Manual (Cat. No. Z365)
(3) Communications command macro data
Refer to Saving and Loading Programs in Vision System FH/FZ5 series Macro Customize
Functions Programming Manual (Cat. No. Z367).
(4) Security settings data
Refer to Saving/Loading/Deleting the Security Settings in Vision System FH/FZ5 Series
User's Manual (Cat. No. Z365).
Precautions for Correct Use
• If the FH sensor controller is in the Multi-line Random-trigger Mode, the settings data for the
FH sensor controller must be saved and loaded for each individual line.
• During saving, do not restart, turn OFF the power supply, or remove the external memory
device. Data will be corrupted and the system will not work properly at the next start-up.
Be particularly careful if you use [Save to file] for [System + Scene group 0 data] because the
data to be saved will also be saved to the flash memory in the Controller at the same time.
2 - 41
2-8-2 Saving and Loading the Settings Data for the FH Sensor Controller
• Loading Settings Data from the Controller RAM Disk or an External Memory Device to
the Sensor Controller in Vision System FH/FZ5 Series User's Manual (Cat. No. Z365)
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2-8 Precautions on Synchronization
through an NJ/NX/NY-series Controller
2-8-2
2 Basic Operations
2-8-3
Transferring Data from the Sysmac Studio
This section describes the following:
• How to download the Sysmac Studio data to the FH sensor controller when synchronizing the Sysmac Studio and the FH sensor controller,
• Procedures for transferring data from the Sysmac Studio via the external memory.
Use the following procedures to synchronize the data from the Sysmac Studio.
1
2
3
Save the settings data for the FH sensor controller that is in the Sysmac Studio to the external
memory.
Establish an online connection with the NJ/NX/NY-series Controller to transfer the data from the
Sysmac Studio to the NJ/NX/NY-series Controller.
Use the external memory that holds the data saved in Step 1 to load the data to the FH sensor
controller.
Sysmac Studio
NJ/NX/NY-series Controller
USB/Ethernet
Downloading
EtherCAT
FH
USB memory/SD memory card
2 - 42
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Procedures for saving the settings data for the FH sensor controller that is in the Sysmac Studio
(Sysmac Studio to external memory)
Save the data in the Sysmac Studio to the external memory. Then use the external memory to
transfer the data to the FH sensor controller. Refer to 2-4-4 Multiview Explorer on page 2-10.
Save following four types of the settings data individually.
(1) System + Scene group 0 data
Refer to 8-3 Using the File Save Tool on page 8-4.
(2) Data for scene groups 1 to 31
Refer to 8-3 Using the File Save Tool on page 8-4.
2-8 Precautions on Synchronization
through an NJ/NX/NY-series Controller
1
2
(3) Communications command macro data
Refer to 8-1 Using the Command Customize Setting Tool on page 8-2.
Refer to 8-7 Using the Security Setting Tool on page 8-11.
Precautions for Correct Use
If the FH sensor controller is in the Multi-line Random-trigger Mode, the settings data for the FH
sensor controller must be saved for each individual line.
2
Procedures for transferring the data from the Sysmac Studio to the NJ/NX/NY-series Controller
(Sysmac Studio to NJ/NX/NY-series Controller)
Establish an online connection with the NJ/NX/NY-series Controller to transfer the data from the
Sysmac Studio to the NJ/NX/NY-series Controller. Refer to Sysmac Studio Version 1 Operation
Manual (Cat. No. W504-E1-08 or later).
(1) Establish an online connection between the NJ/NX/NY-series Controller and the computer
that runs the Sysmac Studio.
(2) Select [Synchronize] from the [Controller] Menu.
(3) Select [Transfer to Sensor].
3
Procedures for transferring the data from the external memory to the FH sensor controller
(external memory to FH sensor controller)
Use the external memory that holds the settings data to load the data to the FH sensor controller. Refer to 2-8-2 Saving and Loading the Settings Data for the FH Sensor Controller on page
2-41.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 43
2-8-3 Transferring Data from the Sysmac Studio
(4) Security settings data
2 Basic Operations
2-8-4
Transferring Data to the Sysmac Studio
This section describes the following:
• How to transfer the data in the NJ/NX/NY-series Controller and the FH sensor controller to the Sysmac Studio when synchronizing the Sysmac Studio and the FH sensor controller,
• Procedures for transferring data to the Sysmac Studio via the external memory.
Use the following procedures to synchronize the data from the Sysmac Studio.
1
2
3
4
Save the settings data for the FH sensor controller in the FH sensor controller from to the external memory.
Establish an online connection with the NJ/NX/NY-series Controller and transfer the data from
the NJ/NX/NY-series Controller to the Sysmac Studio.
Use the external memory that holds the data saved in Step 1 to load the data to the Sysmac Studio.
Save the Sysmac Studio project.
Sysmac Studio
NJ/NX/NY-series Controller
USB/Ethernet
Downloading
EtherCAT
FH
USB memory/SD memory card
2 - 44
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 Basic Operations
Saving the Settings Data for the FH Sensor Controller (FH sensor controller to external memory)
The following section describes the procedures for saving the settings data for the FH sensor
controller to the external memory.
2-8-2 Saving and Loading the Settings Data for the FH Sensor Controller on page 2-41
2
Procedures for transferring the data from the NJ/NX/NY-series Controller to the Sysmac Studio
(NJ/NX/NY-series Controller to Sysmac Studio)
Refer to Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
(1) Establish an online connection between the NJ/NX/NY-series Controller and the computer
that runs the Sysmac Studio.
2-8 Precautions on Synchronization
through an NJ/NX/NY-series Controller
1
2
(2) Select [Synchronize] from the [Controller] Menu.
(3) Select [Transfer to computer].
• Do not restart the FH sensor controller or edit the settings data for the FH sensor controller
from the Sysmac Studio at the timing when [Transfer to computer] is executed.
The values for the settings data that the FH sensor controller manages will be reset to the
factory defaults immediately after the execution of [Transfer to computer]. With default values
set to the settings data, editing the settings data updates the associated I/O Map with the
default values.
Be sure not to restart the FH sensor controller before the completion of the data transfer.
Also, be sure not to save the project before restart of the FH sensor controller.
• If the synchronization with the NJ/NX/NY-series Controller is performed again after the data
transfer to the Sysmac Studio, "
" in the EtherCAT configurations will be displayed.
This is because the settings data for the FH sensor controller has been updated.
If you follow the procedures above, the Sysmac Studio project data matches the data in the
NJ/NX/NY-series Controller.
3
Procedures for transferring the settings data for the FH sensor controller to the Sysmac Studio
(external memory to Sysmac Studio)
Loads the settings data for the FH sensor controller that is in the external memory to the Sysmac Studio. Refer to 2-4-4 Multiview Explorer on page 2-10.
Load following four types of the settings data individually.
(1) System + Scene group 0 data
(2) Data for scene groups 1 to 31
(3) Communications command macro data
Refer to 8-1 Using the Command Customize Setting Tool on page 8-2.
(4) Security settings data
Refer to 8-7 Using the Security Setting Tool on page 8-11.
Precautions for Correct Use
If the FH sensor controller is in the Multi-line Random-trigger Mode, the settings data for the FH
sensor controller must be loaded for each individual line.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
2 - 45
2-8-4 Transferring Data to the Sysmac Studio
Precautions for Correct Use
2 Basic Operations
The following procedures describe how to load the system data and the scene group data.
1
2
3
4
5
Insert the external memory to the computer that runs the Sysmac Studio.
In the Multiview Explorer tree, select the FH sensor controller to which you want to load the
data.
Right-click the selected FH sensor controller and select [Edit] from the menu.
Right-click the line number and select [Load from file] from the menu.
Right-click the FH sensor controller and select [Restart] from the menu.
This operation shows the line with the selected line number in the tree.
6
7
2 - 46
Repeat steps 4 and 5 for each line.
After completion of data transfer for all lines for all FH sensor controllers, save the Sysmac Studio project.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Connecting with a Vision Sensor
3
This section describes how to establish a connection with a vision sensor.
3-1 Adding FH Series Vision Sensor on the Network to a Project . . . . . . . . . . 3-3
3-2 Establishing an Online Connection with a Vision Sensor . . . . . . . . . . . . . 3-4
3-2-1
3-2-2
Establishing an Online Connection from the Sensor Connection Screen . . . . . 3-4
Establishing an Online Connection from the Multiview Explorer . . . . . . . . . . . . 3-6
3-3 Synchronizing Project Data and Sensor Setting Data . . . . . . . . . . . . . . . . 3-8
3-3-1
3-3-2
Transferring Project Data to the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Transferring Setting data in the Sensor to a Project . . . . . . . . . . . . . . . . . . . . . 3-9
3-4 Ending a Connection with a Vision Sensor . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3-4-1
3-4-2
Ending a Connection in the Sensor Connection Screen . . . . . . . . . . . . . . . . . .3-11
Ending a Connection in the Multiview Explorer . . . . . . . . . . . . . . . . . . . . . . . . .3-11
3-5 Logging in to a Registered User's Account . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3-1
3 Connecting with a Vision Sensor
To establish an online connection with FH vision sensor, configure settings and make adjustments, connect directly by Ethernet. You can also connect via a hub or router.
It is not possible to set and adjust FH vision sensor via NJ/NX/NY-series Controller.
Ethernet
Precautions for Correct Use
• If there is already a different FH slave device in the project with an established online connection, you will not be able to establish an online connection for a new FH slave device.
First, switch the other FH slave device from online to offline.
• Do not start the FZ/FH/FJ Simulation Tool and/or FZ_FH Remote Operation tool while using
Sysmac Studio.
• To configure account settings with an FH vision sensor, you will need to log in to your account
while online.
For details on logging in to your account, refer to 3-5 Logging in to a Registered User's
Account on page 3-12.
3-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 Connecting with a Vision Sensor
Adding FH Series Vision Sensor on
the Network to a Project
When creating a new project or adding FH vision sensor to a project, select FH vision sensor on the
network.
When connecting to the FH vision sensor, right-click [Device Group] in the Multiview Explorer and then
select [Add | FH].
3-1 Adding FH Series Vision Sensor on the Network to a
Project
3-1
3
The following sensor selection screen appears.
When establishing an online connection, click [Search for sensors] and then click the [Search] button.
The found sensors are displayed in a list. Select the sensor you wish to connect to and then click the
[OK] button.
If you know the IP address of the sensor you wish to connect to beforehand or will connect to a sensor
via a router, select the [Specify the IP address.] check box and then enter the IP address in [IP
address]. After input is complete, click the [OK] button.
Precautions for Correct Use
If there is already a different FH slave device in the project with an established online connection, you will not be able to select the [Search for sensors] option.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3-3
3 Connecting with a Vision Sensor
3-2
Establishing an Online Connection
with a Vision Sensor
Connect with FH vision sensor on the network.
3-2-1
Establishing an Online Connection from the Sensor Connection
Screen
You can open the sensor connection screen in the Edit Pane by double-clicking the type name of the
FH vision sensor in the Multiview Explorer or by right-clicking it and selecting [Edit] from the menu.
<Multiview Explorer>
3-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 Connecting with a Vision Sensor
3-2 Establishing an Online Connection with a Vision
Sensor
<Sensor connection screen>
3
You can also directly enter an IP address in the IP address field.
If you wish to connect with an FH vision sensor via a router, directly enter the IP address and then click
the [Connect] button.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3-5
3-2-1 Establishing an Online Connection from the Sensor Connection Screen
Click the [Search for sensors] button of [Online] - [Sensor connection] to display a list of the IP
addresses of the FH vision sensors on the same network. Select the FH vision sensor you wish to connect to and then click the [Connect] button.
3 Connecting with a Vision Sensor
3-2-2
Establishing an Online Connection from the Multiview Explorer
If the FH vision sensor to be connected has already been set, you can establish an online connection
with it by right-clicking the type name of the FH vision sensor in the Multiview Explorer and then selecting [Online].
For details on setting the FH vision sensor to be connected, refer to 3-2-1 Establishing an Online Connection from the Sensor Connection Screen on page 3-4.
If the FH vision sensor that has already been set cannot be found, the automatically detected FH vision
sensors are displayed in a list. Select the FH vision sensor you wish to connect to.
Precautions for Correct Use
• When you connect vision sensors to Sysmac Studio by the network, set the same network
addresses for all the vision sensors and computer where Sysmac Studio is running.
e.g., when the Ethernet settings set for the vision sensors are as follows, the network
addresses of the vision sensors and the computer are "10.5.5.*."
IP address: 10.5.5.100
Subnet mask: 255.255.255.0
• If you plan to control the vision sensor from Sysmac Studio over the network, you will need to
have the Remote Operation option for the Communication module for the FH sensor controller set to ON (initial setting).
For details on how to configure the settings, refer to Vision System FH/FZ5 Series User's
Manual (Cat. No. Z365).
3-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 Connecting with a Vision Sensor
However, when there is combination of connections whose version is not supported, the following dialog appears.
3-2 Establishing an Online Connection with a Vision
Sensor
When connecting an FH Sensor Controller whose version does not match the version registered in the
project, the following dialog appears.
3
Precautions for Correct Use
When opening a project that contains settings for FH Sensor Controller whose version is not
supported or does not match the registered version, the following dialog appears.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3-7
3-2-2 Establishing an Online Connection from the Multiview Explorer
If the versions do not match, online editing cannot properly be performed and editing the data offline
cannot be performed after editing it online in some cases. Make sure to connect an FH Sensor Controller whose version matches.
3 Connecting with a Vision Sensor
3-3
3-3-1
Synchronizing Project Data and Sensor Setting Data
Transferring Project Data to the Sensor
Project data and setting data for the FH vision sensor can be synchronized together.
1
Establish an online connection for the vision sensor.
Establish an online connection for the FH vision sensor that you wish to synchronize to the project data.
For details, refer to 3-2 Establishing an Online Connection with a Vision Sensor on page 3-4.
2
Select the data that you wish to have transferred.
The [Data transfer] window will appear once you are online.
Precautions for Correct Use
• An image being managed by the Registered Image Manager Tool will not be transferred.
• When you check the [Scene Group Saving Destination Settings] and transfer processing is
executed as [Transfer to Sensor], the scene group saving destination data saved in the project will be transferred.
• If the saving destination specified in the transferred Scene group saving destination data
does not exist, the saving destination setting will be cleared.
3-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 Connecting with a Vision Sensor
Initiate the data transfer.
To transfer the project data to the FH vision sensor, select [Transfer to Sensor]. Choose [Yes]
when the below message appears to begin the transfer.
Once the transfer is finished, restart the FH vision sensor. Click [OK].
3-3 Synchronizing Project Data and Sensor Setting Data
3
3
To transfer settings data with large file sizes, you will need to use a compatible external memory device that can be inserted into the FH vision sensor.
If the below message appears to indicate that the file size is too large for a normal transfer,
insert a compatible memory device with enough free space to proceed.
3-3-2
Transferring Setting data in the Sensor to a Project
1
Establish an online connection for the vision sensor.
Establish an online connection for the FH vision sensor that you wish to transfer its data to the
project. For details, refer to 3-2 Establishing an Online Connection with a Vision Sensor on page
3-4.
2
Switch to offline.
After establishing an online connection, switch the FH vision sensor to offline.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3-9
3-3-2 Transferring Setting data in the Sensor to a Project
Precautions for Correct Use
3 Connecting with a Vision Sensor
3
Select the data that you want to transfer.
The [Data transfer] window is displayed.
Select the check box of the data that you want to transfer.
4
Initiate the data transfer.
To transfer the setting data in FH vision sensor to the project, select [Transfer to computer].
Choose [Yes] when the below message appears to begin the transfer.
Precautions for Correct Use
To transfer settings data with large file sizes, you will need to use a compatible external memory device that can be inserted into the FH vision sensor.
If the below message appears to indicate that the file size is too large for a normal transfer,
insert a compatible memory device with enough free space to proceed.
3 - 10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 Connecting with a Vision Sensor
Ending a Connection with a Vision
Sensor
End the connection with a sensor currently connected with an online connection and switch to the
offline state.
Additional Information
You can also check and edit settings data while the sensor is offline.
3-4-1
Ending a Connection in the Sensor Connection Screen
Open the sensor connection screen and then click the [Disconnect] button of [Online] - [Sensor connection].
3-4 Ending a Connection with a Vision Sensor
3-4
3
3-4-1 Ending a Connection in the Sensor Connection Screen
3-4-2
Ending a Connection in the Multiview Explorer
Right-click the type name in the Multiview Explorer and select [Offline] from the menu.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
3 - 11
3 Connecting with a Vision Sensor
3-5
Logging in to a Registered User's
Account
If you have an account registered for an FH vision sensor, you will need to log in to the registered user
account whenever you establish an online account with the relevant FH vision sensor. Log in using the
user account for the UG0 group.
1
Establish an online connection with a vision sensor.
Establish an online connection with an FH vision sensor.
For details, refer to 3-2 Establishing an Online Connection with a Vision Sensor on page 3-4.
2
Log in to your account.
If you have a user account registered for an FH vision sensor that is online, the below login
screen will appear. Enter the user account for the registered account for the UG0 group and
then select [OK].
Precautions for Correct Use
This function becomes available when the user name of the account for the FH vision sensor is
changed from default settings.
The default [User name] and [Password] are both "Administrator."
3 - 12
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Configuring Measurement Settings
On the FH vision sensor, processing items can be combined to configure measurement
details. This section provides an overview of the processing units and describes how to
edit a processing unit.
4-1 Overview of Processing Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4-1-1
4-1-2
4-1-3
4-1-4
4-1-5
4-1-6
4-1-7
Input Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compensate Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Branch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display Result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2
4-2
4-2
4-3
4-3
4-3
4-3
4-2 Editing a Processing Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4-2-1
4-2-2
4-2-3
4-2-4
4-2-5
4-2-6
4-2-7
4-2-8
Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Editing an Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Color Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Binary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Detection Point/Reference Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
Image Control Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4-1
4
4 Configuring Measurement Settings
4-1
Overview of Processing Units
This section provides an overview of the processing units that can be edited in the FH tools.
For details on each of the processing units, refer to Vision System FH/FZ5 Series Processing Item
Function Reference Manual (Cat. No. Z341).
4-1-1
Input Image
This is a processing unit for loading images from a camera.
The main setting items are as follows.
Group
Camera setting
Screen adjust
White balance
Calibration
HDR setting
Bright adjust setting
4-1-2
Item
Sets the camera shooting conditions.
Sets the conditions related to the lighting and lens.
Sets the white balance in images loaded from the camera to correct its color
and to make the white parts appear as white.
Configures the settings for converting measurement results to the actual
dimensions.
Sets the method for combining images in order to obtain it with a wide
dynamic range.
Sets how much the brightness of loaded images to be adjusted.
Measurement
This is a processing unit for inspection and measurement.
The main setting items are as follows.
Group
Model
Region setting
Detection point
Ref. setting
Measurement condition
Judgment condition
Output conditions
Color
4-1-3
Item
Allows you to register the parts you wish to inspect as models.
Sets the range for searching a model and the range for calculating the
amount of a certain feature.
Sets which parts of a model you wish to detect as the coordinates during
measurement.
Changes the measurement values that will be the reference registered
during model registration and region setting.
Sets the condition for performing measurement.
Sets the judgment condition for measurement values.
Sets the reflection condition for the coordinates or overall judgment output as
measurement results.
Sets the color information used for measurement.
Compensate Image
This is a processing unit for correcting images.
The main setting items are as follows.
Group
Filter setting
Region setting
Output image
4-2
Item
Sets the filter conditions for image correction.
Sets the region for performing correction.
Selects the image to output.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 Configuring Measurement Settings
4-1-4
Support Measurement
This is a processing unit for providing support for calculation processing, data acquisition and browsing,
and other processing.
The main setting items are as follows.
Setting
Judgment condition
Output parameter
Item
Sets the condition for performing measurement.
Sets the judgment condition for measurement values.
Sets the reflection condition for the coordinates or overall judgment output as
measurement results.
*1. The item names differ for each processing unit.
Precautions for Correct Use
The decimal point symbol in the editing screen for Unit macros and Unit calculation macro processing items is fixed at "." (period), regardless of your computer's OS settings.
4-1 Overview of Processing Units
Group
*1
4
4-1-5
Branch
The main setting items are as follows.
Group
Branch setting
Setting
Output conditions
4-1-6
Item
Sets the condition for performing branching.
Sets the communication function and timeout function for performing flow
control by communication.
Sets the reflection condition for the overall judgment.
Output Result
This is the processing unit for outputting measurement results to an external device.
The main setting items are as follows.
Group
Setting
Output format
Output conditions
4-1-7
Item
Sets the content to output.
Sets the format of the data to output.
Sets the reflection condition for the overall judgment.
Display Result
This is the processing unit for displaying any text, figure, or image on the screen displaying the measurement results.
The main setting items are as follows.
Group
Setting*1
Output conditions
Item
Sets the content or condition to display.
Sets the reflection condition for the overall judgment.
*1. The item names differ for each processing unit.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4-3
4-1-4 Support Measurement
This is the processing unit for performing branching processing.
4 Configuring Measurement Settings
4-2
Editing a Processing Unit
Right-click any processing unit in the flow list and then select [Edit] from the menu.
The editing screen of the selected processing unit appears.
The editing screens of processing units are categorized into the following two types.
<Editing Screen with Image Display>
<Editing Screen without Image Display>
Each setting menu can be opened and closed on a group basis. In an editing screen with image display, an image or graphic information is displayed in accordance with the open menu.
Clicking the [OK] button confirms the changes and closes the editing screen of the processing unit.
Clicking the [Cancel] button discards the changes and closes the editing screen of the processing unit.
The basic editing operations that can be performed with this tool are described below.
4-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 Configuring Measurement Settings
4-2-1
Parameter Settings
The following table lists the basic user interface components used for editing parameters.
UI
Numerical value input
area
(With slider)
After clicking
Before clicking
After clicking
Description
Allows you to enter numerical data.
Entered data is treated as a double type value, but
is displayed up to 4 digits after the decimal point.
Allows you to enter numerical data.
Entered data is treated as a double type value, but
is displayed up to 4 digits after the decimal point.
Clicking the button beside the numerical value input
box displays a slider. Parameter values can be
adjusted with the slider.
Numerical value upper
limit and lower limit
input area
(With slider)
Allows you to enter numerical data for the upper and
lower limits.
Entered data is treated as a double type value, but
is display is up to 4 digits after the decimal point.
Before clicking
After clicking
Before clicking
Numerical value upper
limit and lower limit
input area
(With slider)
(With measurement
value display)
Expression
It is not possible to set a lower limit value that is
greater than the upper limit value.
This is the numerical value upper limit and lower
limit input area with the addition of measurement
value display.
The bar at the place of the measurement value of
the slider is green when the value is OK and red
when it is NG.
Allows you to enter an expression.
When input is complete, a validity check is performed for the expression.
After clicking
Clicking the button beside the text input box displays the calculation parameter input area. Any
parameter can be inserted.
Note When entering a calculation formula, the
decimal point symbol is fixed at "." (period),
regardless of your computer's OS settings.
Text input area
Allows you to enter any text.
The following characters cannot be entered.
• !
Unselected
Radio button
• Tab
Selects one item from multiple selection items.
Check box
Enables or disable an item.
Selected
Unchecked
Checked
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4-5
4
4-2-1 Parameter Settings
Clicking the button beside the numerical value input
box displays a slider. Parameter values can be
adjusted with the slider.
4-2 Editing a Processing Unit
Before clicking
Item
Numerical value input
area
4 Configuring Measurement Settings
UI
Item
Combo box
Before clicking
Description
Selects one item from multiple selection items.
After clicking
4-2-2
Editing an Area
You can edit a model area or measurement area.
Click the area editing button to display the area editing menu.
→
Six area editing functions are provided.
Rectangle
This function draws a rectangle. You can change the size of the rectangle by dragging the four corners.
The rectangle can be moved by clicking and then dragging the inside of the rectangle.
4-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 Configuring Measurement Settings
Wide line
2)
1)
1)
This function draws a wide line. You can change the size or direction by dragging the following vertices.
• Vertex (1)
4-2 Editing a Processing Unit
2)
You can change the length or direction of the line by changing the start point or end point.
• Vertex (2)
4
These allow you to change the width of the line.
4-2-2 Editing an Area
The line can be moved by clicking and then dragging the inside of the area.
Ellipse
3)
2)
2)
1)
3)
This function draws a circle or ellipse. You can change the size by dragging the following vertices.
• Vertex (1)
These allow you to change the overall size while maintaining the XY ratio.
• Vertex (2)
These allow you change the size in the X direction.
• Vertex (3)
These allow you change the size in the Y direction.
The eclipse can be moved by clicking and then dragging the inside of the area.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4-7
4 Configuring Measurement Settings
Circumference
Vertex (1)
Vertex (2)
This function draws a circumference. You can change the size by dragging the following vertices.
• Vertex (1)
These change the radius of the inner circle.
• Vertex (2)
These change the size of the circle while maintaining the difference in the diameters of the inner and
outer circles.
The circumference can be moved by clicking and then dragging the inside of the area.
Wide arc
2)
2)
1)
3)
1)
This function draws a wide arc. You can change the start point, end point, width, and position by dragging the following vertices.
• Vertex (1)
These allow you to change the width.
• Vertex (2)
These allow you to change the start point, end point, and radius.
• Vertex (3)
This allows you to move the center position while keeping the start point and end point positions
fixed.
The arc can be moved by clicking and then dragging the inside of the area.
4-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 Configuring Measurement Settings
Polygon
4-2 Editing a Processing Unit
This function draws a polygon. Up to 10 vertices can be added.
Clicking any position on a side creates a new vertex.
You can change the position of a vertex by dragging it.
The polygon can be moved by clicking and then dragging the inside of the area.
Color Extraction
4-2-3 Color Extraction
4-2-3
4
You can specify up to eight colors.
Also, when the Automatic check box is selected, enclosing any part in a displayed image automatically
extracts the color of that part.
The color range can be specified by specifying the hue, saturation, and brightness.
The specifications are the same as for the user interface of the FH vision sensor.
For details, refer to Vision System FH/FZ5 Series Processing Item Function Reference Manual (Cat.
No. Z341).
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4-9
4 Configuring Measurement Settings
4-2-4
Color
You can specify any color.
The color can be specified by specifying the hue, saturation, and brightness.
The specifications are the same as for the user interface of the FH vision sensor.
For details, refer to Vision System FH/FZ5 Series Processing Item Function Reference Manual (Cat.
No. Z341).
4-2-5
Binary
You can specify the range of binarization levels.
If you select the [Binary Reverse] check box, binarization is performed for outside of the range between
the upper and lower limits.
4 - 10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 Configuring Measurement Settings
4-2-6
Detection Point/Reference Point
4-2 Editing a Processing Unit
The detection point and reference point can be set with the numerical value input boxes.
Clicking any place in the displayed image reflects that coordinate value as the setting value.
4-2-7
List
4
4-2-8
Image Control Area
File selection section
This allows you to select the image to display. Refer to File selection section on page 2-18.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
4 - 11
4-2-6 Detection Point/Reference Point
Selecting an item in the list displays the information for the selected item below the list. Each of the
information items displayed below the list can be edited.
4 Configuring Measurement Settings
Image control section
This allows you to control the measurement of the image. Refer to Image control section on page 2-19.
Image size control section
This allows you to enlarge or reduce the displayed image.
The place where the image is displayed in the left zoom area is enclosed in a rectangle.
You can move the display place by moving this rectangle.
Button
Description
Enlarges the image. Doubles the size of displayed image. (Upper limit: 1600%)
Reduces the image. Halves the size of displayed Image. (Lower limit: 1%)
Makes the image to fit the display frame.
The zoom ratio can be specified by directly entering a numerical value or by moving the
slider.
4 - 12
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Designing Exchange with External
Devices
This section describes how to establish a connection with an external device.
5-1 Setting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
5-1
5 Designing Exchange with External Devices
The FH vision sensor has the following interfaces.
• Parallel I/O
• RS-232C/422
• Ethernet
• EtherCAT
Each interface supports various communication protocols.
You can configure their communication settings in the system settings of the FH tools.
Configure the communication settings for each line when in the multiple multi-line random-trigger
modes. However, some data is settings data that is common to the lines.
Group
Item
Parallel I/O
―
Common to lines
RS-232C/422
Ethernet
EtherNet/IP
EtherCAT
Attribute
Common to lines
―
Address settings
Input/output settings
Common to lines
Individual to each line
Individual to each line
* Some parameters are common to lines
Individual to each line
If the communication settings are changed, the FH vision sensor needs to be restarted.
If a parameter that requires a restart is edited, "
Explorer. If "
" is displayed for the sensor type in the Multiview
" is displayed, save the settings and then restart the FH vision sensor.
For details on restarting, refer to 2-4-4 Multiview Explorer on page 2-10.
5-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
5 Designing Exchange with External Devices
5-1
Setting Procedure
You can open the system settings screen by double-clicking [System data] in the Multiview Explorer or
by right-clicking it and selecting [Edit] from the menu.
For details on the settings, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
5-1 Setting Procedure
In the system settings screen, you can click any of the following buttons to configure the corresponding
settings.
5
Button
Setting Item
Description
Parallel I/O
Sets the Parallel I/O settings.
RS-232C/422
Sets the RS-232C/422 settings.
Ethernet
Sets the settings related to Ethernet.
EtherNet/IP
Sets the settings related to EtherNet/IP.
EtherCAT
Sets the settings related to EtherCAT.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
5-3
5 Designing Exchange with External Devices
Precautions for Correct Use
• A restart is required after configuring the Ethernet, EtherNet/IP, and EtherCAT settings.
• When multi-line random-trigger mode is selected, the communication settings needs to be
configured for each line.
However, the RS-232C/422 settings are common between the lines.
For the other communication settings, individually configure the settings in the system settings for each line.
5-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Online Debugging
This section describes how to perform online debugging of the FH sensor controller.
6-1 Performing Test Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6-1-1
6-1-2
6-1-3
Measuring Camera Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Measuring File Images in the RAMDisk or the External Memory,
i.e. USB Memory of the Vision Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Measuring Logging Images in the Vision Sensor Memory . . . . . . . . . . . . . . . . 6-3
6-2 Checking Measurement Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6-2-1
6-2-2
6-2-3
Checking Detailed Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Changing the Image Display Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Checking Multiple Measurement Images at the Same Time . . . . . . . . . . . . . . 6-6
6-3 Checking Result Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
6-4 Saving Measurement Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6-5 Saving Settings Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
6-6 Loading Settings Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6-1
6
6 Online Debugging
6-1
Performing Test Measurement
You can perform test measurement with the FH tools.
Select from the following three test measurement target images when connected with an online connection.
Target Image
Camera image
Measurement Type
Single measurement
Continuous measurement
Single measurement
File image
Continuous measurement
Single measurement
Logging image
Continuous measurement
6-1-1
Description
Measures a camera image.
Continuously measures camera images.
Allows you to select and measure a file image in the RAMDisk
or the external memory, i.e. USB memory of the FH Vision
Sensor.
Continuously measures file images in the RAMDisk or external
memory, i.e. USB memory of the FH vision sensor. Measurement ends when measurement of the images within the same
folder finishes.
Allows you to select and measure a logging image in the FH
vision sensor memory.
Continuously measures logging images in the FH vision sensor memory. Measurement ends when measurement of all logging images finishes.
Measuring Camera Images
To select a camera image, first click the camera image button (
) in the file selection section.
Then select a camera image and click the [Measure] button.
[Measure] is provided in the following editing screens.
• Scene maintenance window
• Scene editing screen
• Processing unit editing screen
<Scene maintenance window>
<Scene editing screen>
6-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6 Online Debugging
<Processing unit editing screen>
To start continuous measurement, click the continuous measurement button (
).
If you wish to stop continuous measurement, click the continuous measurement stop button (
).
The settings data cannot be edited during continuous measurement.
6-1-2
Select the measurement target file and click the [Measure] button.
Select the file as described below.
1
2
3
Click the [File] button.
Click the file selection button (
) and then select the target file.
Click the [Measure] button.
To start continuous measurement, click the continuous measurement button (
6
).
).
The settings data cannot be edited during continuous measurement.
6-1-3
Measuring Logging Images in the Vision Sensor Memory
Select the measurement target logging image and click the [Measure] button.
Select the file as described below.
1
2
Click the [Logging image] button.
Click the [Measure] button.
If you wish to change the measurement target logging image, click the button for measuring the previous image (
) or click the button for measuring the next image (
).
To start continuous measurement, click the continuous measurement button (
).
If you wish to stop continuous measurement, click the continuous measurement stop button (
).
The settings data cannot be edited during continuous measurement.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6-3
6-1-2 Measuring File Images in the RAMDisk or the External Memory, i.e. USB Memory of the
Vision Sensor
If you wish to stop continuous measurement, click the continuous measurement stop button (
6-1 Performing Test Measurement
Measuring File Images in the RAMDisk or the External Memory,
i.e. USB Memory of the Vision Sensor
6 Online Debugging
6-2
Checking Measurement Results
You can check the measurement results in each editing screen.
On the displayed image, the measurement results of the selected processing unit are displayed as a
graphic.
6-2-1
Checking Detailed Results
Scene maintenance window, monitor window, and scene data editing screen
Open the [Flow] item and [Detail result] item and click the [Measure] button.
If you select any of the processing units in the list of the [Flow] item, the measurement result of each
item that is a judgment result of that processing unit will be displayed in the [Detail result] item.
<Scene maintenance screen>
<Monitor window>
6-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6 Online Debugging
<Scene data editing screen>
6-2 Checking Measurement Results
Processing unit editing screen
Open the [Judgment condition] item and click the [Measure] button.
The measurement result of each item that is a judgment result of the processing unit is displayed
6
6-2-1 Checking Detailed Results
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6-5
6 Online Debugging
6-2-2
Changing the Image Display Settings
You can change the setting for displaying images in the scene maintenance window and monitor window.
Open the [Image display settings] item and change each items.
For details on the image display settings, refer to Image display settings on page 2-17.
Item
Image layout
Image mode
Positions
Sub image
Description
Selects the number of images to display.
Selection items: 1Form, 2Form, and 4Form
Selects the image mode for the image with the focus on it.
Selection items: Through, Freeze, and NG image
Selects position list display for the image with the focus on it.
Selection items: OFF and ON
Selects the sub image number for the image with the focus on it.
Selection items: Image0, Image1,..., image31
You can switch the result display content of the processing unit by changing the sub image number.
For details, refer to the content of each processing unit in Vision System FH/FZ5 Series Processing
Item Function Reference Manual (Cat. No. Z341).
6-2-3
Checking Multiple Measurement Images at the Same Time
You can display multiple images by opening the [Image display settings] item and changing [Image layout].
For details on the image display settings, refer to Image display settings on page 2-17.
<2Form display>
6-6
<4Form display>
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6 Online Debugging
6-3
Checking Result Output
Normally, output to an external device is performed when the monitor window is open, but it is not performed while scene data is being edited in the following editing screens.
• Scene maintenance window
• Scene data editing screen
• Processing unit editing screen
• Editing screen of each tool
If you wish to output the measurement results in those screens, select the following check box in the
adjustment screen.
• [Test measurement settings] - [Output]
6-3 Checking Result Output
6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6-7
6 Online Debugging
6-4
Saving Measurement Results
If you wish to save measurement results or images, use the logging related processing units.
• Image logging
• Image conversion logging
• Data logging
Using these processing unites, allow to output the measurement results to the FH Vision Sensor or the
external memory,i.e. USB memory.
For details on the processing units, refer to Vision System FH/FZ5 Series Processing Item Function
Reference Manual (Cat. No. Z341).
To acquire the files output to the RAMDisk or the external memory, i.e. USB memory of the FH Vision
Sensor, use the file management tool.
For details, refer to 8-3 Using the File Save Tool on page 8-4.
6-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6 Online Debugging
6-5
Saving Settings Data
After adjusting the settings data, you need to save the settings data to the flash memory of the FH
vision sensor. There are the following two ways to save the settings data.
(1) Right-click [Configuration and Setup] - [Device Group] - [FH-XXXX] - [Line X] in the Multiview Explorer and then click [Save data].
6-5 Saving Settings Data
(2) Click the [Data save] button in the scene maintenance window.
6
The settings data can also be saved and managed as files.
• Scene data basis (Refer to 2-5-2 Managing Scenes on page 2-26)
• Scene group basis (Refer to 2-5-6 Managing Scene Groups on page 2-28)
• Processing unit basis (Refer to 2-6-2 Managing Processing Units on page 2-32)
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
6-9
6 Online Debugging
6-6
Loading Settings Data
Loading settings data from file.
(1) Right-click [Configuration and Setup] - [Device Group] - [FH-XXXX] - [Line X] in the Multiview Explorer and then click [Load from file].
(2) From FileExplorer select the System + Scene group data 0 to load from and then click the
[Open] button.
6 - 10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Offline Debugging
This section describes offline debugging techniques for the FH sensor controller.
7-1 Performing Offline Simulation of Sensor Measurement Operation . . . . . 7-2
7-2 Offline Debugging of the Sensor Control Program and Sensor Operation
(Only When Using EtherCAT Connection) . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7-2-1
7-2-2
Control Signals Supported with Offline Debugging . . . . . . . . . . . . . . . . . . . . . . 7-4
Offline Debugging Procedure for the Sensor Control Program . . . . . . . . . . . . . 7-5
7
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7-1
7 Offline Debugging
7-1
Performing Offline Simulation of Sensor
Measurement Operation
Even when offline, simulation of the measurement operation can be performed using file images on the
computer.
Selection and measurement of file image can be performed in the following editing screens.
• Scene maintenance window
• Scene editing screen
• Processing unit editing screen
Select the file as described below.
1
2
3
Click the [File] button.
Click the file selection button (
) and then select the target file.
Click the [Measure] button.
If you click the continuous measurement button ( ), continuous measurement of the images in the
same folder is performed. Measurement ends when measurement of all the files finishes.
If you wish to stop continuous measurement part way through the process, click the continuous measurement stop button (
).
The [Measure] button is provided in the monitor window, scene maintenance window, and processing
unit editing screen.
For details, refer to 6-1-1 Measuring Camera Images on page 6-2.
Additional Information
The images measured with the sensor can be saved as logging image files.
Refer to 8-3-3 Saving a Logging Image as a File on page 8-6.
7-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7 Offline Debugging
Offline Debugging of the Sensor
Control Program and Sensor Operation (Only When Using EtherCAT
Connection)
In a system built with EtherCAT, you can perform simulation with the sequence control of
NJ/NX/NY-series Controller and operation of FH image sensor linked.
Therefore, offline debugging for operation up until the output of the result is possible for measurement
or various other processing performed when a measurement trigger or other control signal is input to
the FH image sensor.
This simulation function is available only in Sysmac Studio (standard edition).
Additional Information
This simulation is supported from the following versions:
• Sysmac Studio (Standard Edition) Ver. 1.08
• FH Software Ver. 5.1*
NJ/NX/NY-series Controller Simulator (virtual Controller)
Sysmac
Studio
Sysmac Studio
7
Simulator
connection
User
program
FH Vision Sensor Simulator
(virtual Vision Sensor)
(1) Trigger signals and control
commands
Image file
(images to measure)
EtherCAT online connection
Computer
7-2 Offline Debugging of the Sensor Control Program and Sensor Operation (Only When Using EtherCAT Connection)
7-2
(3) Outputting measurement results to the
storage area in the NJ/NX/NY-series
Controller
(2) Individual measurements and
control command processing
Operations That Are Possible with Simulation
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7-3
7 Offline Debugging
7-2-1
Control Signals Supported with Offline Debugging
The following table shows the operation of each item that is PDO mapped in offline debugging.
Logic simulation is possible for this offline debugging. The ON/OFF times of each signal is not the same
as the actual processing times.
Item
Trigger
Command
area
User Area
Command
Request
Flow Command
Request
Result Set
Request
Error Clear
DINT User Input
Area 0 to 3
LREAL User Input
Area 4 to 5
Command Completion
BUSY
Trigger Ready
Total Judgement
Run Mode
Response
area
Data area
User Area
Trigger Ack
Command Ready
Shutter Output
Flow Command
Completion
Flow Command
Busy
Flow Command
Wait
Error Status
Result Notification
DINT ResultData
0 to 63
LREAL ResultData 0 to 31
DINT User Output
Area 0 to 3
LREAL User Output Area 4 to 5
Signal Input and Output Timing
Triggers measurement
―
Executes a command
―
Executes a flow command
―
Data output request
―
Clears an error
―
User Input Area
―
User Input Area
―
Command completed
Turns ON when BUSY signal turns OFF.
Processing in progress
Trigger input ready
state
Outputs total judgment
Run mode
Trigger acknowledged state
Ready for command
Outputs shutter trigger
Flow command completed
Executing flow command
Ready for flow command
Error signal
Data output completed
The BUSY ON time is fixed at 10 [PDO cycles].
OFF while BUSY is ON.
Outputs when BUSY turns OFF.
Turns ON when monitor window is open.
Turns ON one [PDO cycle] after trigger input.
OFF while BUSY is ON.
Turns ON for one [PDO cycle] only after trigger input.
Turns ON when Flow Command Busy turns OFF.
ON time of Flow Command Busy is fixed at one [PDO
cycle].
When flow control processing unit is used, turns ON
one [PDO cycle] after BUSY turns ON.
Turns ON when an error occurs.
*1
DINT result data
*1
LREAL result data
*1
User Output Area
―
User Output Area
―
*1. The output timing depends on the operating environment of the computer.
7-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7 Offline Debugging
Offline Debugging Procedure for the Sensor Control Program
You can perform simulation with sequence control and image sensor operation linked to perform offline
debugging. The procedure is as follows.
1
2
Add an image sensor to the EtherCAT slave configuration.
Configure the image sensor settings.
Refer to Section 4 Configuring Measurement Settings.
3
Input a measurement trigger using a control flag and check the result.
The following describes the procedure from adding an image sensor to the EtherCAT slave configuration to checking the result under the assumption that a sequence program has been prepared.
1
Add the [FH-XXXX] vision sensor to the EtherCAT slave configuration using either of the methods below.
• Drag [FH-XXXX] from the [Tool box] and drop it on to the network configuration editing window.
• When the master is selected in the network configuration editing window, double-click
[FH-XXXX] displayed in the [Tool box].
7-2 Offline Debugging of the Sensor Control Program and Sensor Operation (Only When Using EtherCAT Connection)
7-2-2
7
• Match the version of the EtherCAT slave to connected FH sensor controller version. If you
want to choose other than the latest model of FH sensor controller, select [Show all versions]
and then choose the appropriate ESI file revision.
• When adding FH Sensor Controller in the NJ/NX/NY project, the revision displayed in the tool
box is the ESI file revision. The FH Sensor Controller software version that can be selected
will differ depending on the ESI file revision.
Rev:1.1 : FH Sensor Controller Software Ver. 5.5, or later.
Rev:1.0 : FH Sensor Controller Software Ver. 5.3, or earlier.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7-5
7-2-2 Offline Debugging Procedure for the Sensor Control Program
Precautions for Correct Use
7 Offline Debugging
For details on how to register to the EtherCAT slave, refer to 5-1 EtherCAT Configuration and
Settings in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
2
Configure the vision sensor settings.
Double-click [NodeX: FH-XXXX]-[Line X]-[Scene data]/[System data] in the Multiview Explorer.
The corresponding data settings screen appears in the Edit Pane. Configure the various settings.
3
Create device variables.
Create device variables to access the FH.
For details on how to create device variables, refer to 4-1-2 Creating Device Variables in Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
4
Create and build a program to operate the device.
For details on how to create a program, refer to 4-5 Programming in Sysmac Studio Version 1
Operation Manual (Cat. No. W504-E1-08 or later).
5
Open the scene monitor window.
Right-click [FH-XXXX] - [Line X] in the network configuration editing pane and then select [Monitor window].
7-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7 Offline Debugging
Specify the measurement image.
Click the image file selection button and then select an image.
Additional Information
There are no image files immediately after installation of the FH tool. Acquire logged files or
image files saved in the FH unit.
To acquire images, refer to Saving Logged Images in the Controller Memory (RAM) to a RAM
Disk or an External Memory Device in Vision System FH/FZ5 Series User's Manual (Cat. No.
Z365).
7
Select [Simulation] - [RUN].
The simulator starts.
When the simulator connection is complete, the simulator of the NJ/NX/NY-series Controller and
FH vision sensor internally establish an online connection with EtherCAT and the
NJ/NX/NY-series Controller enters the operating state.
For details on how to operate the simulator, refer to 7-3-1 Debugging with Program Simulation in
Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-08 or later).
8
If you operate the control flag from sequence control and execute measurement, you will be
able to check the measurement results in the following monitor window.
7-2 Offline Debugging of the Sensor Control Program and Sensor Operation (Only When Using EtherCAT Connection)
6
7
7-2-2 Offline Debugging Procedure for the Sensor Control Program
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
7-7
7 Offline Debugging
Additional Information
If the run mode (Status Flag: Run Mode) of the response area is OFF when simulation is executed, open the Monitor window.
When the Monitor window is opened, the run mode changes to ON.
Precautions for Correct Use
• Simulations of sensor control programs can only be executed for a single FH vision sensor at
a time while the sensor settings are being edited offline. You cannot run simulations for multiple FH vision sensors at the same time.
• The vision sensor currently being edited offline will have <Editing..> added to the end of the
[Type] in the Multiview Explorer.
• For simulation, the Sysmac error status is not registered as an event in the Sysmac Studio
troubleshooting window.
7-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Other Useful Functions
This section provides a list of useful tools that can be used in the configuration and
operation of the FH series vision sensors.
8-1 Using the Command Customize Setting Tool . . . . . . . . . . . . . . . . . . . . . . . 8-2
8-2 Using the Calibration Support Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8-3 Using the File Save Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8-3-1
8-3-2
8-3-3
Opening the File Save Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
Copying a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
Saving a Logging Image as a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8-4 Using the User Data Setting Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8-5 Changing the System Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
8-6 Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
8-7 Using the Security Setting Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
8-8 Using the Scene Group Saving Destination Setting Tool . . . . . . . . . . . . 8-12
8-9 Using the Image File Save Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
8-9-1
8-9-2
8-9-3
Opening the Image File Save Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Saving the Image File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Saving the Logged Images to Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15
8-10 Using the Registered image Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16
8-11 Using the Update Standard Position Tool . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
8-12 Using the Conversion Scene Group Data Tool . . . . . . . . . . . . . . . . . . . . . 8-18
8-13 Using the Scene Control Macro Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19
8-14 Print the Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20
8-15 Using the Conveyor Panorama Display tool . . . . . . . . . . . . . . . . . . . . . . . 8-21
8-16 Using the Conveyor Calibration Wizard tool . . . . . . . . . . . . . . . . . . . . . . . 8-22
8-17 Using the Calibration Plate Print tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-23
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8-1
8
8 Other Useful Functions
8-1
Using the Command Customize Setting
Tool
This tools allows you to edit custom commands.
It is the same as the [Tools] - [Communication Command Customize] function provided with the FH
vision sensor.
For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
Precautions for Correct Use
The decimal point symbol is fixed at "." (period), regardless of your computer's OS settings.
8-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-2
Using the Calibration Support Tool
A calibration support tool is available.
It is the same as the [Tools] - [Calibration Support Tool] function provided with the FH vision sensor.
For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8-2 Using the Calibration Support Tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8-3
8 Other Useful Functions
8-3
Using the File Save Tool
The file save tool allows you to copy and transfer files in the external memory of the FH vision sensor. It
also allows you to output logging image files in the FH vision sensor memory.
8-3-1
Opening the File Save Tool
To open the File Save Tool, select [Tools] - [Save file] in the Multiview Explorer and then either double-click [Save file] to pull up the Save screen or right-click and select [Edit] from the pop-up menu that
appears.
The file management tool screen appears in the Edit pane.
8-3-2
Copying a File
You can copy a file in the external memory of the FH vision sensor and then save it under a different
name or transfer it to the computer.
8-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
1
2
Select [File] for [Target data].
Select a file.
You can select data on a folder basis or on a file basis.
If you select an individual folder, you can narrow down the files by type.
The following file types can be selected to narrow down the data.
• All files
• Logging images (*.ifz, *.byr)
• Bitmap (*.bmp)
• Jpeg (*.jpg)
• CSV (*.csv)
• Scene data (*.scn)
• Scene group data (*.sgp)
• System data (*.ini)
• System settings + Scene group 0 data (*.bkd)
• Operation log (*.log)
3
Select the save destination folder.
To save the file by copying it to the external memory of the FH vision sensor, select [Sensor].
To save the file to the computer, select [Computer].
8-3 Using the File Save Tool
If you wish to delete the original file after saving, select the [Delete original data after save]
check box.
4
Save the file.
Click the [Save file] button to save the file.
The selected file is copied to the specified folder.
8
8-3-2 Copying a File
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8-5
8 Other Useful Functions
8-3-3
Saving a Logging Image as a File
You can save a logging image in the FH vision sensor memory as a file.
1
2
Select [Logging image] for [Target data].
Select the save target.
Select whether to save all logging images or a particular logging image.
3
Select the save destination folder.
To save the file to the RAMDisk or the external memory, i.e. USB memory of the FH Vision Sensor, select [Sensor].
To save the file to the computer, select [Computer].
4
Save the file.
Click the [Save file] button to save the file.
The selected logging file is output to the specified folder.
8-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-4
Using the User Data Setting Tool
This tool allows you to edit user data.
It is the same as the [Tool] - [User Data] function provided with the FH vision sensor.
For details, refer to the Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8-4 Using the User Data Setting Tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8-7
8 Other Useful Functions
8-5
Changing the System Environment
You can change the system data for the FH vision sensor in the system data editing screen.
Display the system data editing screen in the Edit Pane by double-clicking [System] in the Multiview
Explorer or by right-clicking it and selecting [Edit] from the menu.
System data is classified into the groups shown in Table 1.
Clicking a group icon displays the editing items for the corresponding group.
System data includes parameters that require a restart to reflect the settings.
If a parameter that requires a restart is edited, "
Explorer. If "
" is displayed for the sensor type in the Multiview
" is displayed, save the settings and then restart the FH vision sensor.
For details on restarting, refer to 2-4-4 Multiview Explorer on page 2-10.
For details on each setting item, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8-8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
Table 1
Button
Item
Sub Item
Camera connection
Camera settings
Inter-camera setting
Output signal settings
Startup settings
Fan control setting
STEP setting
Controller settings
Network drive settings
Measurement setting
Image logging settings
Data log settings
Operation log settings
Parallel I/O settings
RS-232C/422 settings
Settings
PLC link settings
Address settings
8-5 Changing the System Environment
Ethernet settings
Settings
Input/Output settings
PLC link settings
EtherNet/IP settings
EtherNet/IP communication
EtherCAT settings
EtherCAT communication
Encoder settings
Encoder settings
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8-9
8 Other Useful Functions
8-6
Help
You can display the FH tool manual.
Display the sensor connection screen in the Edit Pane by double-clicking the type in the Multiview
Explorer or by right-clicking it and selecting [Edit] from the menu.
Click [Sensor Information] - [Help] to display the manual for the FH series vision sensors.
8 - 10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-7
Using the Security Setting Tool
With this tool, it is possible to edit the security settings.
This function is the same as the “Security Setting” function under the “Tool” menu in the FH vision sensor. For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8-7 Using the Security Setting Tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 11
8 Other Useful Functions
8-8
Using the Scene Group Saving Destination Setting Tool
With this tool, it is possible to edit the saving destination for the scene group.
This function is the same as the “Scene Group Saving Destination Setting” function under the “Tool”
menu in the FH vision sensor. For details, refer to Vision System FH/FZ5 Series User's Manual (Cat.
No. Z365).
Precautions for Correct Use
The Scene Group Saving Destination Setting tool cannot be used offline.
8 - 12
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-9
Using the Image File Save Tool
With this tool, it is possible to save the copy of both logged images and image files that are saved in the
Image Sensor to a RAM disk or external memory device in FH Vision Sensor, or to a computer.
The save image file format can be selected from “Bitmap” or “Jpeg”.
8-9-1
Opening the Image File Save Tool
Double-click on [Tool] - [Image file save] in the Multiview Explorer, or by right-clicking it and selecting
[Edit] from the menu.
The image file save tool window is displayed in the Edit Pane.
8-9 Using the Image File Save Tool
8
8-9-1 Opening the Image File Save Tool
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 13
8 Other Useful Functions
8-9-2
Saving the Image File
The image files in the following media can be copied, and then saved in the same media or computer
as bitmap or JPEG.
• RAMDisk of FH vision sensor
• Connected external memory to FH vision sensor
If the file is saved in the JPEG format, it is possible to specify the quality (compression ratio) for each
file.
1
2
Select [Image files] for [Target data].
Select the file.
The options below can be selected:
• save all files in a single specified folder, or
• save a single specified file.
3
Select the save destination folder.
Select [Sensor] to save the file(s) in the RAMDisk of FH Vision Sensor. Select [Computer] to
save the file(s) in the computer. To delete the source file after saving a copy, check [Delete original data after save].
4
Initiate saving.
Click on the [Save file] button to save the image file(s). The selected file(s) are saved as the
specified format.
8 - 14
Setting item
Image format
Setting value
• Bitmap
Description
Select the image format to be saved.
Quality
• Jpeg
0 to 100
Set the quality of the Jpeg image to be saved.
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-9-3
Saving the Logged Images to Files
The logged image files in FH Vision Sensor can be saved as bitmap or JPEG.
1
2
Select [Logging image] for [Target data].
Select the image file.
The options below can be selected:
• save all logged images, or
• save a single specified logged image.
3
Select the save destination folder.
Select [Sensor] to save the file(s) in the RAMDisk of FH Vision Sensor.
Select [Computer] to save the file(s) in the computer.
4
Initiate saving.
Click on the [Save file] button to save the image file(s).
The selected file(s) are saved as the specified format.
8-9 Using the Image File Save Tool
8
8-9-3 Saving the Logged Images to Files
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 15
8 Other Useful Functions
8-10 Using the Registered image Manager
With this tool, it is possible to save images used for model registration and reference registration as
registration images. The saved images can be used for re-registration and adjustment of reference
positions.
For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8 - 16
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-11 Using the Update Standard Position
Tool
With this tool, it is possible to set or change all reference positions at once for multiple processing units
registered in the measurement flow.
This functions the same as the [Update standard position tool] function under the [Tool] menu in the FH
vision sensor. For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8-11 Using the Update Standard Position Tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 17
8 Other Useful Functions
8-12 Using the Conversion Scene Group
Data Tool
With this tool, it is possible to create a scene group that has more than or equal to 129 scenes.
This function is the same as the [Conversion scene group data tool] function under the [Tool] menu in
the FH vision sensor. For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
8 - 18
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-13 Using the Scene Control Macro Tool
With this tool, it is possible to supplement and expand measurement flow and scene control.
This function is the same as the [Scene Control macro tool] function under the [Tool] menu in the FH
vision sensor. For details, refer to Vision System FH/FZ5 Series User's Manual (Cat. No. Z365) or
Vision System FH/FZ5 series Macro Customize Functions Programming Manual (Cat. No. Z367).
8-13 Using the Scene Control Macro Tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 19
8 Other Useful Functions
8-14 Print the Settings
With this function, it is possible to print the parameters set in the system data and currently selected
scene data.
Target data
All information
Scene data
System data
Processing unit
1
Description
Prints all of the sensor information, and parameters set in the system data and
the currently selected scene data.
Prints parameters set in the currently selected scene data.
Prints parameters set in the system data.
Prints parameters set in the processing units.
Open the print window.
Right-click on [Line*] in the Multiview Explorer and select [Print]. The [Print] window is displayed
in the Edit pane.
2
Select the data to be printed.
Select the data to be printed from [Target data].
[Unit No.] should be selected when processing unit is selected from [Target data].
Select the parameter to be printed and expand the tree.
Click on [Expand all] to show all parameters.
3
Initiate printing.
Click on [Print] to print out the parameters shown.
Precautions for Correct Use
This command prints out only the parameters downloaded and uploaded with the Settings
download and upload tools. For details on the "Settings download and upload tools", refer to
Vision System FH/FZ5 Series User's Manual (Cat No. Z365).
8 - 20
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-15 Using the Conveyor Panorama Display tool
This tool is used for conveyor tracking applications.
To adjust the trigger interval and conveyor speed for additional lines or new product types, this tool
combines images to create a panoramic image, and then displays the region of captured image and the
registered region of the model of the target objects for the pick operation over it.
For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
8-15 Using the Conveyor Panorama Display tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 21
8 Other Useful Functions
8-16 Using the Conveyor Calibration Wizard tool
This tool is used for conveyor tracking applications to reciprocally convert different coordinates for
image sensor, conveyor, and robots by giving instructions in a wizard-style.
For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
8 - 22
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 Other Useful Functions
8-17 Using the Calibration Plate Print tool
This tool is used for conveyor tracking applications to print Calibration Pattern.
For more details, refer to Vision Sensor FH Series Conveyor Tracking Application Programming Guide.
8-17 Using the Calibration Plate Print tool
8
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
8 - 23
8 Other Useful Functions
8 - 24
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Limitations
This section provides a list of the limitations associated with the use of the FH sensor
controller with the FH tools.
9-1 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9-2 Synchronization with the NJ/NX/NY-series Controllers . . . . . . . . . . . . . . . 9-5
9
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9-1
9 Limitations
9-1
Limitations
The FH tools have the following limitations.
Condition
Registration of multiple FH
series vision sensors to a
project
Editing of processing units
Limitation
Eight FH vision sensors can be registered to one project.
Limitations apply to editing processing units in Sysmac Studio. Refer to the following table.
List of the processing units supported in Sysmac Studio
Processing Unit
Camera Image Input
Camera Image Input FH
Camera Image Input HDR
Camera Image Input HDR Lite
Camera Switching
Measurement Image Switching
9-2
○: Supported, x: Not supported
Registration
Editing
○
x
○
○
○
○
○
○
○
○
○
○
Multi-Trigger Imaging
○*4
○*4
Multi-Trigger Imaging Task
Position Compensation
Filtering
Background Suppression
○*4
○
○
○
○*4
○
○
○
Brightness Correct Filter
○
Advanced Filter
○
○*1
○
Image Subtraction
○
Color Gray Filter
Extract Color Filter
Anti Color Shading
Stripes Removal Filter II
Polar Transformation
Trapezoidal Correction
○
○
○
○
○
○
Panorama
○
Machine Simulator
Search
Flexible Search
○
○
○
Sensitive Search
○
EC Circle Search
ECM Search
Ec Corner
Ec Cross
Shape Search II
Shape Search III
○
○
○
○
○
○
Classification
○
Edge Position
○
Edge Pitch
○
Scan Edge Position
○
○*1
○
Scan Edge Width
○
○*1
○*1
○
○
○
○
○
○
○*1
○
○
○
○*1
○
○
○
○
○
○
○*1
○
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9 Limitations
Processing Unit
Circular Scan Edge Position
○: Supported, x: Not supported
Registration
Editing
○
○
○
Intersection
Gravity and Area
Labeling
Label Data
○
○
○
○
○*1
○
○
○
○
Color Data
○
○*1
Defect
○
○*1
Precise Defect
○
○*1
Fine Matching
○
○*1
2DCode
○
○*1
Barcode
○
○*1
Character Inspection
○
○*1
Model Dictionary
○
○*1
Date Verification
○
Circle Angle
○
○*1
○
Glue Bead Inspection
○
○*1
OCR
○*2
○*2
OCR User Dictionary
○*2
○
○*2
○
Unit Calculation Macro
○
Circle Regression
Line Regression
Movement Single Position
Movement Multi Points
Convert Position Data
Position Data Calculation
Precise Calibration
Vision Master Calibration
PLC Master Calibration
Reference Calib Data
Camera Calibration
Get Unit Data
Get Unit Figure
Set Unit Data
Set Unit Figure
Detection Point
Image Logging
Image Conversion Logging
Data Logging
Trend Monitor
Statistics
User Data
Data Save
Robot Data
Stage Data
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○*1
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○*3
○*3
Iris
○
○*1
Focus
○
○*1
Calculation
Conveyor Calibration
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9-1 Limitations
Circular Scan Edge Width
9
9-3
9 Limitations
Processing Unit
○: Supported, x: Not supported
Registration
Editing
Unit Macro
○
Wait
Elapsed Time
Parallelize
Parallelize Task
Conditional Branch
DI Branch
End
Selective Branch
Control Flow Normal
Control Flow PLC Link
Control Flow Parallel
Control Flow Fieldbus
Parallel Judgment Output
Data Output
Parallel Data Output
Fieldbus Data Output
Result Display
Display Image File
Display Last NG Image
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○*1
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○*3
○*3
Conveyor Panorama Display
*1. Sysmac Studio ver.1.09 or later is required to register and edit the processing item(s).
*2. FH Sensor Controller ver.5.20 or later is required to register and edit the processing item(s).
*3. FH Sensor Controller ver.5.50 or later is required to register and edit the processing item(s).
*4. FH Sensor Controller ver.5.70 or later is required to register and edit the processing item(s).
Precautions for Correct Use
The below application will run while the FH vision sensor is being edited offline.
FZ-CoreRA 0.exe
Do not attempt to exit this application manually. Exiting this application prematurely may cause
problems to arise with the FH editing. Should the application be closed accidentally, end Sysmac Studio, restart the computer, and try again.
9-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9 Limitations
9-2
Synchronization with the
NJ/NX/NY-series Controllers
Consider the following limitations when synchronizing the project with the NJ/NX/NY-series controller to
which the FH vision sensor is connected.
 Downloading ([Transfer to Controller])
• The setting data in FH vision sensor are not downloaded.
• To download the setting data in FH vision sensor, establish an online connection for the vision
sensor. Refer to 2-8 Precautions on Synchronization through an NJ/NX/NY-series Controller on
page 2-39.
• The global variables allocated to the FH vision sensor I/O ports in the I/O Map are downloaded.
 Uploading ([Transfer to computer])
• The FH vision sensor setting data are initialized after uploading. Be sure to establish an online
connection for FH vision sensor before the synchronization. Refer to 2-8 Precautions on Synchronization through an NJ/NX/NY-series Controller on page 2-39.
• The global variables allocated to the FH vision sensor I/O ports in the I/O Map are downloaded.
For details on the synchronization to the NJ/NX/NY-series controller, refer to Sysmac Studio Version 1
Operation Manual (Cat. No. W504).
9-2 Synchronization with the NJ/NX/NY-series Controllers
• The setting data in FH vision sensor are not uploaded.
9
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
9-5
9 Limitations
9-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
10
Troubleshooting
10-1 Troubleshooting for EtherCAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
10-2 Sysmac Error Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
10 - 1
10 Troubleshooting
10-1 Troubleshooting for EtherCAT
For details on how to perform troubleshooting for EtherCAT, refer to Vision System FH/FZ5 Series
User's Manual for Communications Settings (Cat. No. Z342).
10 - 2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
10 Troubleshooting
For details on Sysmac error statuses, refer to Vision System FH/FZ5 Series User's Manual for Communications Settings (Cat. No. Z342).
10-2 Sysmac Error Status
10-2 Sysmac Error Status
10
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
10 - 3
10 Troubleshooting
10 - 4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
A
Appendices
A-1 Sysmac Device Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
A-1-1
A-1-2
A-1-3
A-1-4
A-1-5
Sysmac Error Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving the Node Address Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial Number Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compliance with ESI Specification (ETG.2000 S (R) V1.0.1) . . . . . . . . . . . . . .
SII Data Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
A-2
A-3
A-4
A-4
A-4
A-1
Appendices
A-1 Sysmac Device Features
The control device product designed according to standardized communications and user interface
specifications for OMRON control devices are called a Sysmac Device.
And the features available with such a Device is called Sysmac Device Features.
A-1-1
Sysmac Error Status
Because, in Sysmac Devices, errors that may occur in slaves are systematized, you can check the
causes and remedies for errors with a common procedure.
The status of an error can be monitored in the Sysmac Error Status (2002-01 hex). To display the error
status detected by the FH series Vision Sensor in Sysmac Studio, the Sysmac Error Status (2002-01
hex) must be mapped to the PDO. Sysmac Studio, by default, uses the 512th transmit PDO Mapping
assignment to map the Sysmac Error Status (2002-01 hex) automatically to the PDO.
Additional Information
• For the Sysmac Error status (2002-01 hex), refer to Vision System FH/FZ5 Series User's
Manual for Communications Settings (Cat. No. Z342).
• For errors displayed in Sysmac Studio, refer to NJ/NX-series Troubleshooting Manual (Cat.
No. W503).
A-2
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Appendices
Saving the Node Address Setting
When the node address switch setting is “00” (Software Setup mode), the node address value you set
in Sysmac Studio is enabled. If the node address switches are set to any other value, the value that is
set on the switches is used as the node address.
In the Software Setup mode, in Sysmac Studio, execute [Write Slave Node Address] on the [EtherCAT
Edit] screen to save the slave node address setting in the nonvolatile memory of the FH series Vision
Sensor.
Software Setting
The set value saved as Slave Information Interface (SII) information in the nonvolatile memory of the
slave is the node address.
(5)
EtherCAT
Slave Controller
Nonvolatile
memory
SII
(2)
Register : 0010h
Register : 0012h
(3)
(1) Node Address
Switch
EtherCAT Slave
(1) The Node Address Switch is set to "00" at
power OFF.
(2) Write a node address set value to Slave SII
from the master.
(3) The value of the node address setting is applied
to Register: 0012 hex by the software, when the
slave power is ON.
(4) EtherCAT master reads the set value of
Register: 0012 hex.
(5) EtherCAT master writes the value of 0012 hex
address to 0010 hex address as the node
address value.
Node Address Switch Setting
The value set on the node address switches is the node address.
EtherCAT master
(3)
(4)
Nonvolatile
memory
SII
EtherCAT
Slave Controller
Register : 0010h
Register : 0012h
(2)
(1) Node Address
Switch
(1) The Node Address Switch is set at power OFF.
(2) The value of Node Address Switch is applied to
Register: 0012 hex, when the slave power is
ON.
(3) EtherCAT master reads the set value of
Register: 0012 hex.
(4) EtherCAT master writes the value of 0012 hex
address to 0010 hex address as the node
address value.
EtherCAT Slave
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
A
A-1-2 Saving the Node Address Setting
EtherCAT master
(4)
A-1 Sysmac Device Features
A-1-2
A-3
Appendices
A-1-3
Serial Number Display
The serial number saved in the nonvolatile memory of the Vision Sensor is displayed in the Serial Number (1018-04 hex). Controllers that support Sysmac Device Features can use this serial number to
check the network configuration. To enable this check, in Sysmac Studio, set [Serial No. Check Condition] to [Set Value = Actual Unit] on the [EtherCAT Edit] screen. If the set condition is not met, a Network
Configuration Check Error will occur.
Additional Information
This network configuration check detects any slave devices that have been replaced, which
prevents you from forgetting to set parameters on those slaves.
A-1-4
Compliance with ESI Specification (ETG.2000 S (R) V1.0.1)
The ESI Specification is a set of specifications that define the entries required in an EtherCAT Slave
Information (ESI) file.
A-1-5
SII Data Check
The Slave Information Interface (SII) is an interface area in the nonvolatile memory of an EtherCAT
slave that stores the configuration information specific to that EtherCAT slave.
Sysmac Device EtherCAT slaves check the SII information from the slave side.
If one of these slaves finds that SII information with which it cannot operate was written, it generates an
SII Check Error (Error No. 88.3). If this error persists even after turning OFF and then ON the power
again, contact your OMRON sales representative.
Precautions for Correct Use
Do not use third-party or any other configuration tools to edit the SII information.
A-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Index
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
I
I-1
Index
Index
Numerics
2DCode .......................................................................... 9-3
2Form display ................................................................. 6-6
4Form display ................................................................. 6-6
A
Adding a Processing Unit ............................................. 2-31
Adding FH Device to a Project ....................................... 2-8
Adding FH Series Vision Sensor on the Network to a Project
3-3
Advanced Filter .............................................................. 9-2
Anti Color Shading ......................................................... 9-2
Application Window ........................................................ 2-9
Area
Circumference .......................................................... 4-8
Ellipse ....................................................................... 4-7
Polygon ..................................................................... 4-9
Rectangle .................................................................. 4-6
Wide arc ................................................................... 4-8
Wide line ................................................................... 4-7
area editing button .......................................................... 4-6
area editing menu ........................................................... 4-6
Author ........................................................................... 2-27
B
Background Suppression ............................................... 9-2
Barcode .......................................................................... 9-3
Basic Design Flow 1 ....................................................... 2-3
Basic Design Flow 2 ....................................................... 2-5
Basic Operations of Flow Editing ................................. 2-30
Basic Operations of Scene Data .................................. 2-25
binarization levels ......................................................... 4-10
Binary ........................................................................... 4-10
Branch ............................................................................ 4-3
brightness ....................................................................... 4-9
Brightness Correct Filter ................................................. 9-2
D
C
Calculation ...................................................................... 9-3
Calibration Plate Print Tool ........................................... 8-23
Calibration Support Tool ........................................ 2-38, 8-3
Camera Calibration ........................................................ 9-3
Camera Image Input ....................................................... 9-2
Camera Image Input FH ................................................. 9-2
Camera Image Input HDR .............................................. 9-2
Camera Image Input HDR Lite ....................................... 9-2
Camera Switching .......................................................... 9-2
Category ......................................................................... 2-6
Changing the image display settings .............................. 6-6
Image layout ............................................................. 6-6
I-2
Image mode .............................................................. 6-6
Positions ................................................................... 6-6
Sub image ................................................................ 6-6
Changing the System Environment ................................ 8-8
Character Inspection ...................................................... 9-3
Checking Measurement Results .................................... 6-4
Checking Multiple Measurement Images at the Same Time
6-6
Checking Result Output ................................................. 6-7
Circle Angle .................................................................... 9-3
Circle Regression ........................................................... 9-3
Circular Scan Edge Position .......................................... 9-3
Circular Scan Edge Width .............................................. 9-3
Classification .................................................................. 9-2
Color ............................................................................. 4-10
Color Data ...................................................................... 9-3
Color Extraction .............................................................. 4-9
Color Gray Filter ............................................................. 9-2
Command Customize Setting Tool ................................. 8-2
Comment ...................................................................... 2-27
Communications command macro ............................... 2-38
Comparison with
FH Series Unit Functions ......2-38, 2-40, 2-41, 2-42, 2-44
Compensate Image ........................................................ 4-2
Conditional Branch ......................................................... 9-4
Configuring Measurement Settings ................................ 4-1
Connecting with a Vision Sensor .................................... 3-1
Control Flow Fieldbus .................................................... 9-4
Control Flow Normal ...................................................... 9-4
Control Flow Parallel ...................................................... 9-4
Control Flow PLC Link ................................................... 9-4
Conversion scene group data tool ................................ 2-38
Convert Position Data .................................................... 9-3
Conveyor Calibration Wizard Tool ................................ 8-22
Conveyor Panorama Display Tool ................................ 8-21
Copying a File .....................................8-4, 8-13, 8-14, 8-15
Creating a New Project .................................................. 2-6
Creating a New Project File from the Project Window ... 2-6
Creating and displaying dedicated dialog boxes .......... 2-38
Data Logging .................................................................. 9-3
Data management for a single FH vision sensor ......... 2-38
Data management for all devices ................................. 2-38
Data Output .................................................................... 9-4
Data save ..................................................... 2-19, 2-21, 9-3
Date Verification ............................................................. 9-3
Defect ............................................................................. 9-3
Deleting FH Device from a Project ................................. 2-8
Description of Screen Components ................................ 2-9
Designing Exchange with External Devices ................... 5-1
Detail result ................................................2-17, 2-19, 2-22
Detection Point ...................................................... 4-11, 9-3
Device ............................................................................ 2-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Index
DI Branch ........................................................................9-4
Display Image File ..........................................................9-4
Display Last NG Image ...................................................9-4
Display Result .................................................................4-3
Downloading and uploading setting values ...................2-38
E
EC Circle Search ............................................................9-2
Ec Corner ........................................................................9-2
Ec Cross .........................................................................9-2
ECM Search ....................................................................9-2
Edge Pitch .......................................................................9-2
Edge Position ..................................................................9-2
Edit Pane ......................................................................2-12
Editing a Processing Unit ................................................4-4
Editing an Area ..........................................................4-6
Parameter Settings ...................................................4-5
Editing an Area ...............................................................4-6
Elapsed Time ..................................................................9-4
End ..................................................................................9-4
Ending a Connection in the Multiview Explorer .............3-11
Ending a Connection in the
Sensor Connection Screen ........................................3-11
Ending a Connection with a Vision Sensor ...................3-11
Entering Scene Group Information ...............................2-29
Entering Scene Information ..........................................2-27
Establishing an Online Connection
from the Multiview Explorer ..........................................3-6
Establishing an Online Connection
from the Sensor Connection Screen ............. 3-4, 3-8, 3-9
Establishing an Online Connection
with a Vision Sensor .....................................................3-4
EtherCAT ........................................................................5-2
Ethernet ..........................................................................5-2
EtherNet/IP .....................................................................5-2
Extract Color Filter ..........................................................9-2
F
Fieldbus Data Output ......................................................9-4
File Save Tool .................................................................8-4
File selection section ........................................... 2-18, 2-21
Filtering ...........................................................................9-2
Fine Matching .................................................................9-3
Flexible Search ...............................................................9-2
Flow .................................................................... 2-16, 2-19
Flow display ..................................................................2-21
Flow viewer ...................................................................2-38
Focus ..............................................................................9-3
Function List ..................................................................2-35
G
Get Unit Data ..................................................................9-3
Get Unit Figure ................................................................9-3
Glue Bead Inspection ......................................................9-3
Gravity and Area .............................................................9-3
H
Help ..............................................................................8-10
hue ..................................................................................4-9
I
Image Control Area .......................................................4-11
Image control section ...........................................2-19, 2-22
Image Conversion Logging .............................................9-3
Image display area ..............................................2-15, 2-18
Image display settings .........................................2-17, 2-19
Image file save ..............................................................2-38
Image Logging ................................................................9-3
Image size control section ...................................2-15, 2-19
Image Subtraction ...........................................................9-2
Input Image .....................................................................4-2
Intersection .....................................................................9-3
Iris ...................................................................................9-3
L
Label Data ......................................................................9-3
Labeling ..........................................................................9-3
Limitations .......................................................................9-1
Line Regression ..............................................................9-3
List ................................................................................4-11
M
Machine Simulator ..........................................................9-2
Managing Processing Units ..........................................2-32
Managing Scene Groups ..............................................2-28
Managing Scenes .........................................................2-26
Measure ...............................................................2-19, 2-21
Measurement ..................................................................4-2
Measurement Image Switching ......................................9-2
Measuring Camera Images ............................................6-2
Menu Bar ......................................................................2-10
Model Dictionary .............................................................9-3
Monitor window .............................................................2-14
Movement Multi Points ....................................................9-3
Movement Single Position ..............................................9-3
Multi-Trigger Imaging ......................................................9-2
Multi-Trigger Imaging Task ..............................................9-2
Multiview Explorer .........................................................2-10
N
NG analyzer ..................................................................2-38
O
OCR ................................................................................9-3
OCR User Dictionary ......................................................9-3
Offline Debugging ...........................................................7-1
Offline Simulation ............................................................7-2
Opening the File Save Tool .............................................8-4
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
I-3
I
Index
Output Result ................................................................. 4-3
Overview of Processing Units ........................................ 4-2
P
Panorama ....................................................................... 9-2
Parallel Data Output ....................................................... 9-4
Parallel I/O ...................................................................... 5-2
Parallel Judgment Output ............................................... 9-4
Parallelize ....................................................................... 9-4
Parallelize Task .............................................................. 9-4
Parameter Settings ......................................................... 4-5
Performing Test Measurement ....................................... 6-2
PLC Master Calibration .................................................. 9-3
Polar Transformation ...................................................... 9-2
Position Compensation .................................................. 9-2
Position Data Calculation ............................................... 9-3
Precise Calibration ......................................................... 9-3
Precise Defect ................................................................ 9-3
Processing unit
Copy ....................................................................... 2-32
Delete ..................................................................... 2-32
Edit ......................................................................... 2-32
Load from file .......................................................... 2-32
New folder .............................................................. 2-32
Paste ...................................................................... 2-32
Rename .................................................................. 2-32
Save to file .............................................................. 2-32
project ............................................................................. 1-3
Project Management ...................................................... 1-3
R
Reference Calib Data ..................................................... 9-3
Reference Point ............................................................ 4-11
Registered Image Manager .......................................... 2-38
Result Display ................................................................ 9-4
Robot Data ..................................................................... 9-3
RS-232C/422 .................................................................. 5-2
S
saturation ........................................................................ 4-9
Save file ........................................................................ 2-38
Saving a Logging Image as a File .................................. 8-6
Saving Measurement Results ........................................ 6-8
Saving Settings Data ...................................................... 6-9
Scan Edge Position ........................................................ 9-2
Scan Edge Width ............................................................ 9-2
Scene
Copy ....................................................................... 2-26
Delete ..................................................................... 2-26
Load from file .......................................................... 2-26
Paste ...................................................................... 2-26
Save to file .............................................................. 2-26
Scene Control macro tool ............................................. 2-38
Scene data editing screen ............................................ 2-20
Scene group
Copy ....................................................................... 2-28
I-4
Delete ..................................................................... 2-28
Load from file .......................................................... 2-28
Paste ...................................................................... 2-28
Save to file .............................................................. 2-28
Scene group data (scene data) ...................................... 1-4
Scene group Name ...................................................... 2-29
Scene Group Saving Destination Settings ................... 2-38
Scene maintenance area ............................................. 2-20
Scene maintenance window ........................................ 2-18
Scene Name ................................................................ 2-27
Screen customization and screen layout control .......... 2-38
Search ............................................................................ 9-2
Searching for a Processing Unit ................................... 2-34
Searching for a Scene .................................................. 2-27
Security settings ........................................................... 2-38
Selective Branch ............................................................ 9-4
Sensitive Search ............................................................ 9-2
Sensor connection screen ............................................ 2-13
Set Unit Data .................................................................. 9-3
Set Unit Figure ............................................................... 9-3
Shape Search II ............................................................. 9-2
Shape Search III ............................................................ 9-2
Single simulation .......................................................... 2-38
Stage Data ...................................................................... 9-3
Statistics ......................................................................... 9-3
Status display area .............................................. 2-14, 2-18
Stripes Removal Filter II ................................................. 9-2
Support Measurement .................................................... 4-3
Switching Scene Groups .............................................. 2-27
Switching Scenes ......................................................... 2-26
System data ................................................................... 1-4
System data editing screen .......................................... 2-22
T
Test measurement settings .......................................... 2-19
Tool data ......................................................................... 1-4
Tool settings editing screen .......................................... 2-23
Toolbar ......................................................................... 2-10
Toolbox ......................................................................... 2-24
Transferring Project Data to a Sensor ............................ 3-8
Trapezoidal Correction ................................................... 9-2
Trend Monitor ................................................................. 9-3
Troubleshooting ............................................................ 10-1
U
Unit Calculation Macro ................................................... 9-3
Unit Macro ...................................................................... 9-4
Update standard position tool ....................................... 2-38
User Data ....................................................................... 9-3
User data ...................................................................... 2-38
User Data Setting Tool ................................................... 8-7
Using the Scene Control Macro Tool ............................ 8-19
V
Vision Master Calibration ............................................... 9-3
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
Index
W
Wait .................................................................................9-4
I
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
I-5
Index
I-6
Vision System FH Series Operation Manual for Sysmac Studio (Z343)
OMRON Corporation
Industrial Automation Company
Kyoto, JAPAN
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2013-2017 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. Z343-E1-08
0617
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement