T8 Instant Start
Table of Contents
T8 Instant Start Ballasts
Ballasts
gelighting.com
T8 Instant Start
Understanding T8 Fluorescent Ballasts.......................10-2
Understanding Fluorescent Systems............................10-3
Fluorescent Ballast Application Notes ........................10-5
T8 Programmed
Start
UltraMax® Instant-Start Multi-Voltage
120–277V High-Efficiency
For F17 (2 ft), F25 (3 ft), F32 (4 ft),
F40 (5 ft) Lamps.......................................................................... 10-7
For 46 – 59W 4 ft–8 ft Slimline Lamps......................... 10-22
Programmed
Start Dimming
UltraMax® 347V High-Efficiency.................................. 10-24
UltraMax® Bi-Level Dimming and Load Shed Dimming
Instant Start 120–277V High-Efficiency..................... 10-32
T5 Electronic
Programmed Start
ProLine® T8 Multivolt 120V–277V
For F17 (2 ft), F25 (3 ft), F32 (4 ft),
F40 (5 ft) Lamps........................................................................10-40
For 46 – 59W 4 ft–8 ft Slimline Lamps......................... 10-50
ProLine® T8 Multivolt, High Output 120V–277V
For 44 – 86W 4 ft–8 ft High Output Lamps..................10-51
T12 Electronic
& High Output
ProLine® T8 Instant-Start
120V and 277V High-Performance
For F17 (2 ft), F25 (3 ft), F32 (4 ft),
F40 (5 ft) Lamps........................................................................10-52
For 46 – 59W 4 ft–8 ft Slimline Lamps...........................10-56
ProLine® T8 347V Instant-Start
High Performance...........................................................10-57
T12 Magnetic
Residential Grade ProLine® T8 120V
For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps........................10-60
Electromagnetic T8 120V and 277V Ballasts
For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps........................10-61
Wiring Diagrams.............................................................10-62
Case Dimensions............................................................10-65
Sign
Compact
Fluorescent
10-1
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Understanding T8
Fluorescent Ballasts
A comprehensive range of solutions…from GE, the name you trust.
GE introduced the first fluorescent ballast more than 60 years ago. Today we are providing
high-frequency electronic ballasts for almost every fluorescent application.
With our UltraMax® and UltraStart® ballasts, we are bringing you
the future in ballast performance.
GE revolutionizes lighting again with breakthrough technology. Our patented UltraMax®
instant-start and UltraStart® programmed start electronic ballasts transform the power of
light into efficiency and savings from store shelves to the installation site. The foundation of
the “Ultra” family of ballasts starts with its high efficiency ratings. High efficiency ballasts
are a ­minimum of 90% efficiency with some ballasts nearly 95% efficient which means the
ballast only consumes 5-10% of the total system power. These high efficiency ballasts exceed
­minimum high efficiency standards as established by almost all energy advocate groups, ­utility
rebate programs and the NEMA Premium® ballast program. The ballasts are marked with the
Ultra brand as well as the NEMA Premium® ballast mark. These ballasts have multi-voltage
control (MVC), which automatically adjusts to handle voltage from 120V through 277V. That
cuts the ballast models you need to stock from 40 down to 13, which can dramatically reduce
inventory carrying costs. UltraMax® ballasts have ArcGuard Protection, too, with a UL Type CC
Anti-Arc Rating. Plus, they’re ultra-lamp-friendly, with a low lamp current crest factor of 1.4 for
optimal lamp performance. Both UltraMax® and UltraStart® have anti-striation control for
better light quality with no lamp striations (spiraling). And the small, low-profile design of
these ballasts makes retrofits effortless at the job site. Also unique to our programmed start
UltraStart® ballasts is parallel lamp operation which means that if one lamp fails the others
remain on, and quick starting times of less than 700 milliseconds which is necessary in
avoiding delays with automatic sensors.
GE Fluorescent Ballast Types
Electronic Instant Start
The most common fluorescent ballast is the instant start and is used typically in long 3 to
10-hour lamp cycle applications. These ballasts are energy efficient and can deliver 20% to
40% energy savings when installed with energy-efficient lamps in building retrofits. These
ballasts deliver >550 open circuit volts when starting lamps and operate lamps at high
frequencies which offers flicker-free operation and better lamp efficiencies.The ballasts are
significantly quieter than conventional magnetic ballasts and are backed by GE’s ultra system
5-year ballast limited warranty and extended lamp ­warranties.
10-2
See page E-1 for warranty information.
3 2 - M V P S - N - 4 2 T
GE Ballast
GE = LFL
GEC = CFL
IS = Instant Start,
Lamp Watts
standard if not shown
(Primary Lamp)
RS = Rapid Start
T8 = 32-four foot,
PS = Program Start
59-eight foot
Maximum
T12 = 40-four foot,
number
60-eight
foot
of lamps
Ballast Factor
supported
120 = 120 volt
L =Low Power for
by this ballast 277 = 277 volt
MAX savings
– 1, 2, 3, 4, 6
MAX or MV =
N = Normal for
120 – 277V
New Fixtures
N+ = Normal High 1.0
H = High Power,
Hi-Light, Hi-Bay
Ultra-Hi Efficiency
84T, 42T, T = 840, 420 qty
OEM pallet packs
A, D, E, F = Can sizes
BES = Bottom exit with studs
SE = Dual – side & bottom exit
3W = 3 way mounting kit
Understanding
Fluorescent Systems
Date Codes
GE electronic ballast manufacturing date codes are located on the
upper right-hand corner of the label. The code lists the month, year
and day of manufacture. A typical code is C06-073, where the month
is listed as A (January), B (February), C (March) (as in this code) followed
by the year 06 (20026) and the date of ­manufacture 073 (the 73rd day
of 20026).
The F32T8 lamp has a “nominal” wattage of 32 watts. Nominal means
“in name only” because there are no ballasts commercially available
that will operate this lamp at 32 watts! The “N” or “Normal” ballast
factor ballast operates this at around 26 watts while the “L” operates
the lamp around 23 watts; the “N+” operates it around 29 watts and
the “H” around 34 watts. Electronic ballasts operate lamps at high
frequencies of greater than 20 kHz, which results in more efficient
lamp operation than at 60 kHz, like the magnetic ballasts they replace.
This results in a lamp that is more efficient than the 32 nominal watts.
See page E-1 for warranty information.
10-3
HID Electronic &
Electromagnetic
Ballast Factor
Compact
Fluorescent
Ballast Date Codes
Sign
GE introduced the first practical fluorescent lamp in 1938. All
fluorescent lamps operate on electrical control gear called a
ballast. Today, electronic ballasts have continued to replace the
magnetic designs that were common previously. The 4-foot T8
lamp on an electronic ballast is the most common system. The
generic version of this lamp is called the F32T8 and in recent years,
energy saving reduced wattage lamps like the F28T8 and the
F32T8/25W have become popular. These lamps typically operate
on Instant Start (IS) or Programmed Rapid Start (PRS) ballasts and
both types of ballasts are available in a variety of ballast factors
ranging from 0.60 to 1.18.
T12 Magnetic
UltraStart®
UltraStart® is a family of high-efficiency GE Programmed Start
­electronic linear fluorescent ballasts that also exceed NEMA Premium®
­ballast efficiency requirements but are designed to optimize GE’s
T8 Ultra lamps in frequently switched applications. Instant start
ballasts provide 7,000-13,000 starts before 50% lamp failure.
­UltraStart® ­provides greater than 100,000 starts before 50% lamp
failure. U
­ ltraStart® ballasts provide the same energy savings and
­convenience of instant start ballasts but with the longer lamp life
offered a programmed start ­ballast. These ballasts are offered in
ballast factors: programmed start x-low wattage (XL) (.60), low
wattage (.71), normal light (.87), and high (>1.15).
G E - 2
T12 Electronic
& High Output
Programmed Start electronic ballasts have a lamp starting method
that preheats lamp filaments before applying an open circuit voltage
(OCV) to start the lamp. Use ­Programmed Start ballasts to ensure long
lamp life when turning lamps on and off more than five times in a
day or in conjunction with any automatic light control or sensor. This
type of starting circuit keeps lamp-end blackening to a minimum and
improves lamp life ­performance, especially in applications where the
lamps are ­frequently switched on and off.
GE Ballast Electronic nomenclature
T5 Electronic
Programmed Start
Programmed Start
Instant Start vs. Rapid Start Sockets
When using programmed start or dimming ballasts in fixtures,
sockets must be 2-pin rapid start type. Fixtures with T8 instant
start ballasts must use jumpered rapid start sockets or shunted
lamp holders (internal to the lamp holder) that bridge the lamp
bi-pins together into one contact on each side of the lamp. If
­retrofitting from a instant start ballast fixture with shunted
sockets to a dimming or programmed start ballast, rapid start
type sockets must be used to properly start lamps and maintain
rated lamp life.
Programmed
Start Dimming
UltraMax® Bi-Level (S60) Dimming and Load Shed (V60) Dimming
These extremely high efficiency multi-volt (120-277V) electronic
ballasts offer the benefits of a low cost instant start design but the
flexibility to dim from 100% to 60% or load shed dim with a 0-10V
controller anywhere between 100% and 60%. With F32T8 lamps there
is a direct 40% energy reduction when dimming from 100% to 60%
light level reduction. Lamp life is not impacted by dimming from
high to low. For applications with more than 5 starts per day, a
programmed start (PS) or PS dimming ballast is recommended.
T8 Programmed
Start
ProLine®
Offered in dedicated or multi-volt (120-277V), these high-performance
T8 instant-start ballasts also meet minimum efficiency requirements
as established with the NEMA Premium® ballast program. These
­ballasts are offered in ballast factors: low wattage (.77), normal light
(.87), and high (>1.15).
Ballast Life
GE electronic ballasts are designed and manufactured to an
average life expectancy of 60,000 hours of operation at maximum
rated case temperatures. As a rule of thumb, ballast life is doubled
for every 10C reduction in ballast case temperature. However
there are other variables such as transients, voltage sags and
swells, ambient temperature, etc., which affect ballast life as well.
T8 Instant Start
UltraMax®
A family of high-efficiency GE T8 instant-start electronic linear
­fluorescent ballasts designed to optimize GE’s T8 Ultra lamps for
optimal system energy savings. UltraMax® ballasts have a low lamp
current crest factor and virtually “read” and adapt to incoming voltage
from 108V to 305V. Other features include UL Type CC Anti-Arc Rating
and anti-striation control to eliminate lamp striations and spiraling.
These ballasts are offered in ballast factors: low wattage (.77), normal
light (.87), normal-high (N+) (1.0) and high (>1.15).
Ballasts
gelighting.com
Unlike HID lamps and Incandescent/Halogen lamps which are
designed for optimum performance at a specific wattage, linear
fluorescent lamps can be operated over a reasonably wide range
without sacrificing performance, such as life or efficacy. Therefore,
there is no “optimum” wattage for a lamp, only a range. The F32T8
lamp can produce between 60% to 118% of its catalog lumens when
operated on a ballast with a ballast factor of 0.60 to 1.18. The higher
the operating wattage, the higher the lumen output within this range.
Consumers have a choice among ballasts, depending on how much
light they desire from the lamp and how much energy they are trying
to save. The ballast specification from the ballast manufacturer provides the “input wattage” of the ballast. A two lamp electronic ballast
with input watts of 56 watts (BF of 0.88) is using 56 watts of power to
operate 2 lamps--typically 26 watts in each lamp and 4 watts in the
ballast. In contrast, a ballast with BF of 1.18 will consume 76 watts
but also produce more light.
An engineer or designer will choose a high BF when trying to
“squeeze” as much light as possible from the lamp, e.g. in high-bay
applications or when they are trying to reduce the number of lamps
used in the area. A lower BF reduces the light output and wattage
of each lamp, so that more lamps (and more fixtures) are needed to
achieve a certain footcandle level in the same area. Of course more
fixtures also means closer spacing and more uniform lighting.
It must be noted that ballast factor (and any measure involving BF)
requires a measurement of lamp lumens and is, therefore, not a pure
electrical measurement. The uncertainty and variation associated
with individual lamp performance is present in these measures.
Actual Light Output of Lamp = (Catalog Lumens) x (Ballast Factor)
There are two major families of ballasts. While the current limiting
function is the same, these ballasts differ in how they start the lamp.
Instant Start (IS) Ballasts apply a relatively high voltage (e.g. 550 volts)
to get the discharge going and the lamp starts instantaneously.
(GE’s UltraMax® family)
Programmed Rapid Start (PRS) Ballasts provide a gentler start
through cathode heating prior to application of starting voltage, and
are particularly useful when lamps are turned on and off frequently
(motion sensors, occupancy sensors). However, they are being used
even in one-start-a-day applications because they extend lamp life
significantly. (GE’s UltraStart® family)
Ballast Efficacy Factor (BEF)
BEF is BF (Ballast factor) divided by ballast input watts. For a given
BF and a certain number of lamps operated on the ballast, the more
efficient ballast will have lower watts and, therefore, a higher BEF.
Ballast
Efficacy (BEF)
=
Factor
Ballast Factor
x
Ballast Input Watts
100
Some industry groups write standards based on BEF in order to
identify more efficient ballasts. However, this measure is somewhat
obscure and an alternate measure that is simpler to understand is:
System Efficacy (Mean System LPW or MLPW)
This is the mean source lumens provided by the particular system
divided by the watts the system is using.
Ballast Factor
Light Output
Instant Start and Programmed Rapid Start Ballasts
Mean
Source =
Lumens
Lamp Mean
X
Lumen Rating
Ballast
X
Factor
Number
of Lamps
and
N+
N Normal
L Low
L low
XL
H High
1.18
System
Efficacy
=
(MLPW)
Mean Source Lumens
Ballast Input Watts
The Consortium on Energy Efficiency (CEE) uses both BEF and MLPW
in its documents on high performance T8 specifications and reduced
wattage T8 specifications. The rebate programs of many utilities
around the country currently use these two measures to determine
which systems will qualify for rebates.
1.00
0.87
0.77
Ballast Electrical Efficiency (BE)
0.71
A simple electrical measure of how efficiently a ballast performs is:
0.60
System Watts
Ballast
=
Efficiency
Watts Delivered to Lamps
Ballast Input Watts
NEMA (National Electric Manufacturer’s Association) uses
Ballast Efficiency (BE) as an alternative method to designate
“NEMA PREMIUM” ballasts as those having 90% or greater
electrical efficiency. BE is gaining increasing acceptance as an
objective and reproducible measure because it excludes the
variability present in individual lamp performance and the
difficulties associated with accurate determination of lumens.
10-4
See page E-1 for warranty information.
Wire bundling can create unintended current flows from lead to
lead and also from lead to ground in the fixture. These current
flows are parasitic, and will reduce the available starting voltage,
preheating current or discharge current in the lamp. The results
can be poor or erratic starting or reduced system efficacy as some
of the energy from the ballast is getting “short circuited” away
from the intended lamp load. In T5 or CFL applications, excessive
stray capacitance can also affect End Of Life circuit operation,
causing the ballast to prematurely shut down.
HID Electronic &
Electromagnetic
10-5
Compact
Fluorescent
In summary, the lamp lead wiring should be laid parallel into the
fixture with excess length trimmed. Do not twist or otherwise
bundle the leads together, and ensure no leads are caught or
crimped between the ballast channel cover and the fixture body.
Sign
In dual switched systems, or systems that use two or more ballasts
within the same fixture, ballasts more subject to cross talk and
interference due to capacitive effects. It is important the wiring be
placed neatly without bunching up the excess in the wiring channel. Lamp leads can run parallel to each other but should not be
bundled or tied together. Lamp leads should also trimmed when
possible to eliminate excess lead length. It is also good to keep the
output leads from one ballast away from those of the other ballast.
Lamp leads should also be kept away from the AC input leads as
this can cause undesired interference or EMI, which can affect
other devices operating on the same power source.
T12 Magnetic
See page E-1 for warranty information.
When installing ballasts into fixtures, the wiring needs to be
routed point to point and if possible, the excess wire trimmed out.
Occasionally, some installers tend to be too neat, twisting the wires
together or bundling the wires together with wire ties. While this
does make for a neat fixture, it may create capacitive effect issues
for the lamp and ballast system.
T12 Electronic
& High Output
Dimming Applications
As ballast efficiency increases, controls and dimming ballasts will
deliver the next level of energy savings. Proper installation and set up
is needed to ensure the system will deliver the energy savings while
maximizing lamp life. GE dimming ballasts are available for load shed
as well as deep dimming operation. Dimming applications generally
use full wattage lamps, but GE UltraMax 28W lamps are also suitable
for use on GE dimming ballasts. The ballast must be mounted in
the same fixture as the lamps, no tandem or remote operation is
permitted for programmed start dimming ballasts. In order to achieve
maximum lamp performance, the lamps should be seasoned at full
power per NEMA guidelines prior to dimming operation. Ballasts for
programmed start dimming must use rapid start type lampholders
that accommodate two separate wires that connect one to each
lamp pin. Shunted or shorted lampholders cannot be used with
programmed start dimming systems. Load shed ballasts are instant
As ballasts decrease in size, the operation frequency increases. The
increased frequency of operation makes capacitive effects more
pronounced. Capacitive effects come from a high frequency lead
wire being in proximity to another lead wire or the grounded metal
of the fixture. Worse capacitive effects result when the lead wires
are closer and the frequency is higher.
T5 Electronic
Programmed Start
Energy Saving Lamps
Energy saving lamps lower the lamp operating wattage by use of
special gas mixtures. These lamp are sometimes harder to strike or
break down than full wattage lamps and due to the gas mixture, may
be more susceptible to striations during operation. GE Ballasts feature
proprietary anti striation circuitry that minimize or completely
eliminate striation effect of energy saving lamps. Ballast remote
mounting distance is specified for standard full wattage lamps only.
Fixture Wiring Techniques
Electronic ballasts are now much more popular than the old
magnetic ballasts, offering superior energy efficiency, greater
lamp efficacy, and cooler operation. The first electronic ballasts
operated only slightly above the audible frequency range around
22 kHz. As today’s ballasts operate at high frequency, typically
40 kHz and higher, some attention is needed to ensure the fixture
wiring does not create any starting or operational issues due to
wiring capacitance.
Programmed
Start Dimming
EMI and RFI
All electronic ballasts operate at frequencies that generate
Electromagnetic Interference or Radio Frequency Interference.
GE Ballasts are tested by FCC certified labs to ensure their emissions
are well within the established limits for Class A Commercial and
Industrial applications. Some GE ballasts are designed for Residential
applications and meet a more stringent Class B Consumer FCC rating.
The Consumer rating will minimize chances of the ballast interfering
with radio and television reception. If interference results, ensure the
ballast case is properly grounded to the metal fixture, and the fixture
is grounded by a green ground wire that connects directly to the
service panel. As the electromagnetic spectrum is increasing occupied,
it is recommended to test a sample lamp and ballast system in the
intended environment to ensure there are no undesired interactions
with other equipment or systems operating in the same environment.
T8 Programmed
Start
Ballast Operating Lifetime
Heat is the enemy of modern electronic ballasts. As ballast case
temperature increases, life expectancy decreases. GE ballast designs
feature patented high efficiency circuits that have less losses and
lower internal heat generation than competitive ballasts. Ballast
lifetime is developed from thermal testing conducted per UL specified
test conditions at a 40°C still air ambient condition. Some GE ballasts
are even UL approved for use at 55°C ambient without exceeding the
maximum permissible case temperature. Since GE ballasts typically
operate well below the maximum temperature rating, the ballast
lifetime will usually extend longer that the design life of 60,000
hours. Reducing the case temperature by 10°C will double the life
expectancy, but this depends on the operating environment which
includes ambient temperature, fixture thermal performance and
input voltage conditions.
start and can be used with shunted lampholders. The load shed
ballast can be used in some tandem fixture applications with
total lead length determined by the specific application. GE
programmed start dimming ballasts are compatible with 0-10V
Class 1 or Class 2 wiring systems rated as ANSI Type 1. GE load
shed ballasts feature step or variable 0-10V control. The step
options include Class 1 compatible control and dual input leads
for double switched applications such as classrooms.
T8 Instant Start
Fluorescent Ballast
Application Notes
Ballasts
gelighting.com
Remote and Tandem Mounting of Ballasts
As today’s economics drive lower first costs, many fixture manufacturers increasingly use only one ballast to operate lamps in two or
more fixtures. This tandem mounting scheme decreases the total
number of ballasts needed for a given installation. The fixtures are
typically interconnected with a wiring “whip” of flexible metal conduit
with a number of wires inside. The whip brings the high frequency
lamp leads from the ballast in one fixture to the lamp or lamps in a
satellite fixture. Tandem operation has lamps operating in the fixture
that has the ballast and also in the satellite fixture.
Remote mounting is when a ballast is located in a separate enclosure
without lamps and wires to all the lamps run through a conduit or
flexible whip to a remote fixture which contains the lamps.
In past years, ballasts were magnetic and operated at 60 Hz, and
tandem or remote mounting scheme was only occasionally used,
so issues with remote or tandem mounting were not so frequent.
In today’s energy efficient electronic ballasts, the frequency is much
higher, usually greater than 40 kHz, and more fixtures are being
tandem operated to manage first costs of a system. Tandem
operation can lead to system issues such as poor or erratic starting
and differences in light level during steady state lamp operation.
It is recommended that dimming ballasts not be remote mounted or
used in tandem operation, all lamp wiring must stay within the fixture
containing the dimming ballast.
Energy saving lamps may be more susceptible to starting issues when
used in remote or tandem fixture operation. These lamps utilize a gas
mixture that does not ionize as easily as full wattage lamps, and are
more likely to have starting issues due to the reduced starting voltage
resulting from the capacitive losses.
Remote starting distances are specified at room temperature using
standard life, full wattage lamps, with one ballast driving all lamps
located in the remote fixture through a single conduit at the specified
distance. In view of the possible differences related to any specific
application, it is advised that any tandem or remote mount application
using one or more ballasts be tested in the final configuration to ensure
the system will perform as expected in the intended environment.
These issues develop when the combination of high operating
frequency and parasitic capacitance from the wiring create
unintended coupling between conductors or to earth ground.
Each wire in the fixture and the interconnect whip will have a
certain capacitance to other wires running parallel to it, and also a
capacitance to earth ground. This unintended capacitive coupling
creates a shunt path taking away some energy that was intended for
the lamp load. This causes reductions in the available open circuit
voltage need to strike the lamp or a loss of preheating energy. Both
cases lead to poor or erratic starting in the remote fixture(s).
For some multiple lamp ballasts, certain lamp leads are at higher
potential and should be connected to lamps that reside in the same
fixture as the ballast. The ballast manufacturer may have specific
recommendations as to which of the lamp leads can be utilized for
the remote fixture of a tandem set, and restrictions on how long the
wiring from ballast to lamp may be. Ballasts may also have different
permissible wiring lengths per lamp lead color based on the application. Remote mounting applications may permit a longer wiring length
than some tandem applications as the remote situation presents a
uniform loss to all lamp leads. The tandem operation scheme may
present different capacitances to different lamp leads that could
result in poor starting and differences in light level during operation.
In some cases, these issues are compounded because the interconnect whip is carrying wires connected to two different ballasts.
Since the ballasts are not likely to be exactly in phase, there can be
additional losses due to capacitive phase cancellation between leads
of the two different ballasts. There may also be system interactions
where either ballast will work fine separately, but will not work
together. In these cases, the interconnect whip may need to be
shorter, limiting the distance between the fixtures, or two separate
whips could be used.
As the ballast operating frequency gets higher, the capacitive
shunting effect become more pronounced. Dimming ballasts typically
are at the highest frequency when in deep dimming. Due to the
effects of capacitive losses, lamps may appear at different intensities
or drop out and may flicker due to losses of cathode heating energy.
10-6
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
1 – F32T8 120 to 277 “L” .77 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72258
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
34 in (864 mm)
41 in (1041 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F28T8
F32T8/25W
F25T8
F17T8
FE15T8
Safety and performance
System Watts
25
25
24
24
20
22
21
21
20
20
14
14
11
11
21
21
Nom. Line Current
0.21 A
0.09 A
0.20 A
0.09 A
0.08 A
0.09 A
0.00 A
0.00 A
0.17 A
0.08 A
0.12 A
0.06 A
0.09 A
0.05 A
0.18 A
0.08 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.77
0.77
0.78
0.78
0.78
0.78
0.77
0.77
0.81
0.81
0.79
0.79
0.77
0.77
0.80
0.80
Ballast Efficacy Factor
3.08
3.08
3.25
3.25
3.90
3.55
3.67
3.67
4.05
4.05
5.64
5.64
7.00
7.00
3.81
3.81
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
96
99
95
93
94
99
97
99
93
99
88
99
77
99
94
cUL Listed
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
UL Type CC
UL Listed
THD% (<=)
6
9
6
9
11
10
10
10
7
11
9
13
11
21
7
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
T12 Electronic
& High Output
F25T12
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8/WM
# of Lamps
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Programmed
Start Dimming
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (>90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
T8 Instant Start
72258 – GE132MAX-L/ULTRA (replaces 49706)
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-7
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72259 – GE-132MAX-N/ULTRA (replaces 49771)
UltraMax® Instant Start Multi-Voltage High-Efficiency
1 – F32T8 120 to 277 “N” .87 BF UltraMax®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72259
• Energy-saving high-efficiency instant-start electronic ballast (>90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
37 in (940 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
FE15T8
F25T12
# of Lamps
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
System Watts
28
28
26
26
25
25
23
23
23
23
16
16
13
13
24
24
Nom. Line Current
0.23 A
0.10 A
0.22 A
0.10 A
0.21 A
0.09 A
0.00 A
0.00 A
0.19 A
0.09 A
0.14 A
0.07 A
0.11 A
0.06 A
0.20 A
0.09 A
UL Type 1 Outdoor
UL Type CC
System Ballast Factor
0.87
0.87
0.88
0.88
0.88
0.88
0.88
0.88
0.93
0.93
0.92
0.92
0.92
0.92
0.94
0.94
UL Type HL
Ballast Efficacy Factor
3.11
3.11
3.38
3.38
3.52
3.52
3.83
3.83
4.04
4.04
5.75
5.75
7.08
7.08
3.92
3.92
FCC – CLASS A Non-Consumer
49775 – GE232MAX-H/ULTRA
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “H” 1.15 BF UltraMax®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electrical characteristics
50 Hz/60 Hz
Order information
10 Pack
49775
UL Class P
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
cUL Listed
UL Listed
THD% (<=)
6
8
6
8
6
9
10
10
7
9
9
11
10
12
6
9
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Supply Current Frequency
Power Factor% (>=)
99
96
99
96
99
95
99
97
99
94
99
84
99
78
99
95
Pallet Pack
47548
DIY Pack
IP Pack
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue
Red
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
25 in (635 mm)
31 in (787 mm)
45 in (1143 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
System Watts
Nom. Line Current
2
120
74
0.62 A
2
277
73
0.27 A
1
277
41
0.16 A
F32T8
1
120
40
0.36 A
2
120
71
0.59 A
2
277
70
0.26 A
1
120
39
0.34 A
F32T8/WM
1
277
39
0.15 A
2
120
66
0.58 A
2
277
65
0.26 A
1
120
36
0.32 A
F28T8
1
277
36
0.15 A
Other compatible lamps: FE15T8, F40T8, F25T8, F25T12, F17T8, F32T8/25W
Safety and performance
10-8
UL Type 1 Outdoor
NRCan
System Ballast Factor
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
UL Type HL
Ballast Efficacy Factor
1.55
1.57
2.80
2.87
1.61
1.64
2.94
2.94
1.74
1.76
3.19
3.19
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
96
99
99
98
99
96
99
97
99
96
RoHS Compliant
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
UL Class P
cUL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
UL Type CC
Min. Starting Temp (°F/°C)
-22 / -30
-22 / -30
-22 / -30
-22 / -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
UL Listed
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Pallet Pack
73191
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
25 in (635 mm)
31 in (787 mm)
37 in (940 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8/UMX
F17T8
FE15T8
F40T8
Safety and performance
Nom. Line Current
0.62 A
0.27 A
0.40 A
0.18 A
0.58 A
0.26 A
0.36 A
0.17 A
0.54 A
0.24 A
0.34 A
0.16 A
0.48 A
0.21 A
0.30 A
0.14 A
0.35 A
0.16 A
0.24 A
0.12 A
0.28 A
0.13 A
0.20 A
0.10 A
0.46 A
0.21 A
0.52 A
0.23 A
0.33 A
0.15 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
1.19
1.19
1.38
1.38
1.16
1.16
1.37
1.37
1.15
1.15
1.34
1.34
1.16
1.16
1.37
1.37
1.17
1.17
1.37
1.37
1.02
1.02
1.21
1.21
.66
.66
1.11
1.11
1.36
1.36
UL Type HL
Ballast Efficacy Factor
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
97
99
95
99
97
99
94
99
97
99
93
99
96
99
92
99
94
99
89
99
90
99
85
99
96
99
97
99
94
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Class P
cUL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
11
10
10
10
10
10
10
UL Type CC
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
UL Listed
T12 Magnetic
F25T12
System Watts
74
73
48
48
69
68
43
43
65
64
40
40
57
57
37
37
41
41
29
29
33
33
25
25
56
55
63
62
40
40
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8 and U
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
1
1
2
2
1
1
Programmed
Start Dimming
Order information
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
White
Blue
Red
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
10 Pack
73190
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• >68 kHz lamp frequency EAS system friendly
T8 Instant Start
73190 – GE232MAX-H
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-9
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72262 – GE232MAX-L/ULTRA (replaces 49707)
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “L” .77 BF UltraMax®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
White
Red
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72262
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Pallet Pack
72263 (replaces 47546)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
31 in (787 mm)
25 in (635 mm)
37 in (940 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
FE15T8
F25T12
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-10
System Watts
49
48
28
28
47
46
27
27
43
43
25
25
38
38
22
22
39
39
23
23
27
27
17
17
21
22
14
15
41
41
24
24
Nom. Line Current
0.42 A
0.18 A
0.23 A
0.11 A
0.39 A
0.17 A
0.23 A
0.10 A
0.36 A
0.16 A
0.21 A
0.10 A
0.00 A
0.00 A
0.00 A
0.00 A
0.33 A
0.14 A
0.19 A
0.09 A
0.23 A
0.10 A
0.14 A
0.08 A
0.18 A
0.09 A
0.12 A
0.07 A
0.35 A
0.15 A
0.20 A
0.09 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.77
0.77
0.77
0.77
0.78
0.78
0.78
0.78
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.80
0.80
0.80
0.80
0.79
0.79
0.79
0.79
0.78
0.78
0.78
0.78
0.80
0.80
0.80
0.80
UL Type CC
Ballast Efficacy Factor
1.57
1.60
2.75
2.75
1.66
1.70
2.89
2.89
1.79
1.79
3.08
3.08
2.03
2.03
3.50
3.50
2.05
2.05
3.48
3.48
2.93
2.93
4.65
4.65
3.71
3.55
5.57
5.20
1.95
1.95
3.33
3.33
RoHS Compliant
UL Type HL
Power Factor% (>=)
99
98
99
95
99
98
99
95
99
98
99
94
99
98
99
97
99
97
99
93
99
95
99
80
99
93
99
73
99
98
99
94
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
FCC – CLASS A Non-Consumer
UL Class P
THD% (<=)
5
8
8
12
5
9
8
12
6
9
8
13
10
10
10
10
6
10
9
13
8
12
11
36
9
13
12
40
6
9
9
13
cUL Listed
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
UL Listed
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “N” .87 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72266
Pallet Pack
72267 (replaces 31052)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
37 in (940 mm)
25 in (635 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F17T8
FE15T8
Safety and performance
Nom. Line Current
0.47 A
0.20 A
0.26 A
0.12 A
0.45 A
0.19 A
0.24 A
0.11 A
0.41 A
0.18 A
0.23 A
0.11 A
0.00 A
0.00 A
0.00 A
0.00 A
0.38 A
0.16 A
0.21 A
0.98 A
0.27 A
0.12 A
0.16 A
0.08 A
0.21 A
0.97 A
0.13 A
0.08 A
0.40 A
0.17 A
0.22 A
0.10 A
UL Type 1 Outdoor
RoHS Compliant
System Ballast Factor
0.87
0.87
0.87
0.87
0.88
0.88
0.88
0.88
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.93
0.93
0.93
0.93
0.92
0.92
0.92
0.92
0.91
0.91
0.91
0.91
0.93
0.93
0.93
0.93
UL Type HL
Ballast Efficacy Factor
1.61
1.64
2.81
2.81
1.66
1.69
3.03
2.93
1.78
1.81
3.11
3.11
1.98
2.02
3.48
3.48
2.07
2.07
3.72
3.58
2.88
2.88
4.84
4.84
3.64
3.64
6.07
5.69
1.94
1.98
3.58
3.44
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
99
99
96
99
99
99
96
99
98
99
95
99
98
99
97
99
98
99
94
99
96
99
87
99
95
99
78
99
98
99
95
UL Class P
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
cUL Listed
UL Type CC
THD% (<=)
5
8
7
12
5
8
7
12
4
8
7
13
10
10
10
10
6
10
8
13
7
13
9
16
8
16
11
40
5
9
7
13
NRCan
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
UL Listed
T12 Magnetic
F25T12
System Watts
54
53
31
31
53
52
29
30
49
48
28
28
44
43
25
25
45
45
25
26
32
32
19
19
25
25
15
16
48
47
26
27
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Programmed
Start Dimming
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
White
Black
Blue
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
T8 Instant Start
72266 – GE232MAX-N/ULTRA (replaces 49772)
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-11
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
71421 – GE232MAX-N+
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
71421
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Pallet Pack
DIY Pack
IP Pack
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
31 in (787 mm)
45 in (1143 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
System Watts
Nom. Line Current
2
120
63
0.53 A
2
277
62
0.23 A
1
277
35
0.13 A
F32T8
1
120
34
0.29 A
2
120
60
0.50 A
2
277
60
0.22 A
1
277
33
0.13 A
F32T8/WM
1
120
33
0.28 A
2
120
58
0.48 A
2
277
57
0.21 A
1
120
32
0.26 A
F28T8
1
277
32
0.12 A
2
120
56
0.47 A
2
277
56
0.21 A
1
120
31
0.26 A
F25T12
1
277
31
0.12 A
Other compatible lamps: FE15T8, F25T8, F17T8, F40T8, F32T8/25W
Safety and performance
10-12
UL Type 1 Outdoor
RoHS Compliant
System Ballast Factor
1.00
1.00
0.96
0.96
1.00
1.00
0.97
0.97
1.00
1.00
0.98
0.97
0.97
0.97
0.95
0.95
UL Type CC
Ballast Efficacy Factor
1.59
1.61
2.77
2.81
1.67
1.68
2.91
2.96
1.79
1.75
3.11
3.02
1.74
1.75
3.11
3.05
UL Type HL
NRCan
Power Factor% (>=)
99
98
96
99
99
98
96
99
99
98
99
96
99
98
99
96
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
FCC – CLASS A Non-Consumer
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
10
18
UL Class P
cUL Listed
Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78619
Pallet Pack
78620 (replaces 71715)
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
31 in (787 mm)
37 in (940 mm)
25 in (635 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F17T8
FE15T8
F25T12
Safety and performance
Nom. Line Current
0.99 A
0.41 A
0.75 A
0.32 A
0.91 A
0.38 A
0.70 A
0.30 A
0.83 A
0.35 A
0.65 A
0.28 A
UL Type 1 Outdoor
0.79 A
0.34 A
0.62 A
0.26 A
0.53 A
0.23 A
0.41 A
0.20 A
0.42 A
0.20 A
0.33 A
0.16 A
0.89 A
0.37 A
0.83 A
0.35 A
0.63 A
0.27 A
UL Type HL
System Ballast Factor
1.18
1.18
1.29
1.29
1.18
1.18
1.26
1.26
1.18
1.18
1.26
1.26
1.18
1.18
1.26
1.26
1.14
1.14
1.26
1.26
1.15
1.15
1.27
1.27
1.03
1.03
1.13
1.13
1.26
1.26
1.10
1.10
1.23
1.23
Ballast Efficacy Factor
1.06
1.08
1.52
1.54
1.13
1.16
1.59
1.62
1.24
1.26
1.73
1.75
1.31
1.34
1.83
1.88
1.27
1.27
1.80
1.85
1.89
1.92
2.70
2.70
2.15
2.15
3.05
3.05
1.34
1.37
1.17
1.20
1.73
1.73
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
95
99
97
99
95
99
97
99
98
99
97
cUL Listed
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Type CC
UL Listed
THD% (<=)
10
10
10
16
10
10
10
16
10
10
10
17
10
10
10
10
10
10
10
18
10
10
10
21
10
19
10
21
10
15
10
13
10
17
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
F40T8
System Watts
111
109
85
84
104
102
79
78
95
94
73
72
90
88
69
67
90
90
70
68
61
60
47
47
48
48
37
37
94
92
94
92
71
71
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
2
2
3
3
2
2
Programmed
Start Dimming
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
T8 Instant Start
78619 – GE332MAX-H/ULTRA (replaces 71714)
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-13
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
78621 – GE332MAX-L/ULTRA (replaces 71717)
UltraMax® Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “L” .77 BF UltraMax®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78621
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
Pallet Pack
78622 (replaces 71718)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
37 in (940 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
FE15T8
F25T12
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-14
System Watts
73
72
58
58
69
68
54
54
64
64
49
49
58
57
44
44
62
61
47
47
42
42
32
33
33
33
26
26
62
61
48
48
Nom. Line Current
0.66 A
0.28 A
0.51 A
0.23 A
0.62 A
0.27 A
0.48 A
0.21 A
0.57 A
0.25 A
0.43 A
0.19 A
UL Type 1 Outdoor
0.54 A
0.24 A
0.42 A
0.19 A
0.36 A
0.18 A
0.28 A
0.14 A
0.29 A
0.14 A
0.23 A
0.12 A
0.54 A
0.24 A
0.42 A
0.19 A
UL Type CC
System Ballast Factor
0.77
0.77
0.89
0.89
0.77
0.77
0.87
0.87
0.77
0.77
0.84
0.84
0.77
0.77
0.84
0.84
0.77
0.77
0.86
0.86
0.78
0.78
0.87
0.87
0.70
0.70
0.77
0.77
0.70
0.70
0.80
0.80
UL Type HL
Ballast Efficacy Factor
1.05
1.07
1.53
1.53
1.12
1.13
1.61
1.61
1.20
1.20
1.71
1.71
1.33
1.35
1.91
1.91
1.24
1.26
1.83
1.83
1.86
1.86
2.72
2.64
2.12
2.12
2.96
2.96
1.13
1.15
1.67
1.67
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
96
99
98
99
97
99
97
99
96
99
96
99
94
99
95
99
92
99
97
99
97
UL Class P
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
cUL Listed
UL Listed
THD% (<=)
10
10
10
10
10
10
10
12
10
10
10
13
10
10
10
10
10
10
10
14
10
16
10
17
10
17
11
20
10
10
10
13
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “N” .87 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78623
Pallet Pack
78624 (replaces 71721)
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
25 in (635 mm)
37 in (940 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F17T8
F25T12
Safety and performance
Nom. Line Current
0.72 A
0.31 A
0.56 A
0.25 A
0.68 A
0.29 A
0.51 A
0.23 A
0.62 A
0.27 A
0.47 A
0.21 A
UL Type 1 Outdoor
0.59 A
0.26 A
0.20 A
0.45 A
0.40 A
0.18 A
0.31 A
0.15 A
0.31 A
0.16 A
0.25 A
0.13 A
0.60 A
0.26 A
0.46 A
0.21 A
UL Type HL
System Ballast Factor
0.87
0.87
0.97
0.97
0.87
0.87
0.95
0.95
0.87
0.87
0.93
0.93
0.87
0.87
0.93
0.93
0.84
0.84
0.94
0.94
0.86
0.86
0.97
0.97
0.77
0.77
0.86
0.86
0.78
0.78
0.89
0.89
Ballast Efficacy Factor
1.06
1.09
1.52
1.54
1.13
1.14
1.61
1.64
1.24
1.24
1.72
1.75
1.34
1.36
1.86
1.94
1.25
1.25
1.84
1.84
1.91
1.91
2.77
2.77
2.14
2.14
3.07
3.07
1.15
1.16
1.71
1.71
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
98
97
99
99
97
99
95
99
96
99
93
99
98
99
97
cUL Listed
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Type CC
UL Listed
THD% (<=)
10
10
10
13
10
10
10
15
10
10
10
16
10
10
10
10
10
13
17
10
10
17
10
19
10
23
10
23
10
13
10
16
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/ 30
-22.0/-30
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
FE15T8
System Watts
82
80
64
63
77
76
59
58
70
70
54
53
65
64
50
48
67
67
51
51
45
45
35
35
36
36
28
28
68
67
52
52
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
277
120
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
Programmed
Start Dimming
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
White
Red
Blue
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
T8 Instant Start
78623 – GE332MAX-N/ULTRA (replaces 71719)
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-15
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
71422 – GE332MAX-N+
UltraMax® Instant Start Multi-Voltage High-Efficiency
3 or 2 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal – High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
71422
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Pallet Pack
DIY Pack
IP Pack
Wiring diagram LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Blue
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
45 in (1143 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
System Watts
3
120
91
3
277
90
2
120
64
F32T8
2
277
64
3
120
87
3
277
86
2
120
61
F32T8/WM
2
277
61
3
120
83
3
277
82
2
120
59
F28T8
2
277
59
3
120
80
3
277
79
2
120
57
F25T12
2
277
57
Other compatible lamps: F25T8, F15T8, F40T8, F17T8, F32T8/25W
Safety and performance
10-16
RoHS Compliant
Nom. Line Current
0.77 A
0.33 A
0.54 A
0.24 A
0.73 A
0.32 A
0.52 A
0.23 A
0.69 A
0.30 A
0.50 A
0.22 A
0.67 A
0.29 A
0.48 A
0.22 A
UL Type 1 Outdoor
System Ballast Factor
1.00
1.00
0.94
0.94
1.00
1.00
0.95
0.95
1.00
1.00
0.96
0.95
0.93
0.93
0.93
0.93
UL Type CC
Ballast Efficacy Factor
1.09
1.11
1.47
1.48
1.15
1.17
1.55
1.56
1.21
1.23
1.62
1.62
1.16
1.18
1.63
1.65
UL Type HL
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
FCC – CLASS A Non-Consumer
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
UL Class P
cUL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
19
Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
4 or 3 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
71723
Pallet Pack
71724 (replaces 47550)
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
31 in (787 mm)
31 in (787 mm)
39 in (991 mm)
Specifications
Lamp
F28T8
F32T8/25W
F17T8
FE15T8
F25T12
Safety and performance
Nom. Line Current
1.30 A
0.55 A
1.07 A
0.46 A
1.21 A
0.51 A
0.99 A
0.41 A
1.10 A
0.48 A
0.91 A
0.40 A
UL Type 1 Outdoor
0.45 A
1.06 A
0.87 A
0.38 A
0.62 A
0.31 A
0.57 A
0.27 A
0.54 A
0.26 A
0.45 A
0.22 A
1.27 A
0.54 A
1.10 A
0.47 A
0.90 A
0.39 A
UL Type HL
System Ballast Factor
1.18
1.18
1.28
1.28
1.18
1.18
1.25
1.25
1.18
1.18
1.24
1.24
1.18
1.18
1.24
1.24
1.16
1.16
1.27
1.27
1.16
1.16
1.25
1.25
1.03
1.03
1.12
1.12
1.22
1.22
1.11
1.11
1.22
1.22
Ballast Efficacy Factor
0.80
0.81
1.08
1.09
0.85
0.87
1.11
1.12
0.93
0.94
1.18
1.22
0.98
1.02
1.25
1.31
0.97
0.96
1.26
1.27
1.47
1.49
2.02
2.02
1.66
1.66
2.20
2.15
0.84
0.86
0.89
0.91
1.21
1.22
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
97
99
97
99
98
99
97
99
98
99
97
97
99
99
96
99
96
99
95
99
95
99
92
99
97
99
97
99
97
cUL Listed
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Type CC
UL Listed
THD% (<=)
10
10
10
15
10
10
10
16
10
10
10
16
10
10
10
10
10
10
10
17
10
10
10
21
10
20
10
20
10
14
10
14
10
17
Min. Starting Temp (°F/°C)
-22.0/ -30
-22.0/ -30
-22.0/ -30
-22.0/ -30
50.0/ 10
50.0/ 10
50.0/ 10
50.0/ 10
50.0/ 10
50.0/ 10
50.0/ 10
50.0/ 10
60.0/ 16
60.0/ 16
60.0/ 16
60.0/ 16
-22.0 /-30
-22.0/ -30
-22.0/ -30
-22.0/ -30
-22.0/ -30
-22.0/ -30
-22.0/ -30
-22.0/ -30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
-22.0/ -30
-22.0/ -30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
F40T8
System Watts
148
145
119
117
139
136
113
112
127
125
105
102
120
116
99
95
119
121
101
100
79
78
62
62
62
62
51
52
146
142
125
122
101
100
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
277
120
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
3
3
4
4
3
3
Programmed
Start Dimming
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Blue
Yellow
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
T8 Instant Start
71723 – GE432MAX-H/ULTRA (replaces 49777)
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-17
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
78625 – GE432MAX-L/ULTRA (replaces 71725)
UltraMax® Instant Start Multi-Voltage High-Efficiency
4 or 3 – F32T8 120 to 277 “L” .77 BF UltraMax®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
Low
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram - LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
Black
White
Yellow
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78625
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
Pallet Pack
78626 (replaces 71726)
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
34 in (864 mm)
31 in (787 mm)
31 in (787 mm)
39 in (991 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
FE15T8
F25T12
# of Lamps
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-18
System Watts
97
96
84
83
92
91
72
76
86
84
68
67
77
75
61
60
82
81
68
67
56
56
47
47
44
44
36
37
82
81
68
67
Nom. Line Current
0.88 A
0.37 A
0.74 A
0.32 A
0.82 A
0.35 A
0.68 A
0.29 A
0.75 A
0.32 A
0.62 A
0.27 A
UL Type 1 Outdoor
0.72 A
0.31 A
0.59 A
0.26 A
0.50 A
0.22 A
0.41 A
0.20 A
0.38 A
0.18 A
0.32 A
0.16 A
0.72 A
0.31 A
0.60 A
0.26 A
UL Type CC
System Ballast Factor
0.77
0.77
0.88
0.88
0.77
0.77
0.83
0.83
0.77
0.77
0.81
0.81
0.77
0.77
0.81
0.81
0.76
0.76
0.83
0.83
0.81
0.81
0.87
0.87
0.70
0.70
0.76
0.76
0.70
0.70
0.76
0.76
UL Type HL
Ballast Efficacy Factor
0.79
0.80
1.05
1.06
0.84
0.85
1.15
1.09
0.90
0.92
1.19
1.21
1.00
1.03
1.33
1.35
0.93
0.94
1.22
1.24
1.45
1.45
1.85
1.85
1.59
1.59
2.11
2.05
0.85
0.86
1.12
1.13
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
97
99
96
99
95
99
95
99
93
99
97
99
97
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Class P
cUL Listed
THD% (<=)
10
10
10
10
10
10
10
12
10
10
10
13
10
10
10
10
10
11
10
14
10
16
10
17
10
17
11
20
10
10
10
13
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
50.0/10
50.0/10
50.0/ 10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
UL Listed
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
4 or 3 – F32T8 120 to 277 “N” .87 BF UltraMax®
General characteristics
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
55°C (131°F)
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78627
Pallet Pack
78628 (replaces 71729)
DIY Pack
71730 (replaces 23942)
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
31 in (787 mm)
25 in (635 mm)
39 in (991 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F25T8
F17T8
F25T12
Safety and performance
Nom. Line Current
0.97 A
0.41 A
0.81 A
0.81 A
0.91 A
0.38 A
0.75 A
0.32 A
0.82 A
0.35 A
0.68 A
0.29 A
UL Type 1 Outdoor
0.78 A
0.33 A
0.65 A
0.28 A
0.51 A
0.24 A
0.45 A
0.21 A
0.42 A
0.20 A
0.35 A
0.17 A
0.80 A
0.34 A
0.66 A
0.29 A
UL Type HL
System Ballast Factor
0.87
0.87
0.94
0.94
0.87
0.87
0.91
0.91
0.87
0.87
0.89
0.89
0.87
0.87
0.89
0.89
0.82
0.82
0.90
0.90
0.87
0.87
0.96
0.96
0.77
0.77
0.85
0.85
0.79
0.79
0.87
0.87
Ballast Efficacy Factor
0.80
0.81
1.02
1.03
0.84
0.86
1.07
1.08
0.93
0.95
1.16
1.17
1.00
1.01
1.25
1.25
0.92
0.93
1.22
1.23
1.43
1.43
1.88
1.88
1.60
1.60
2.07
2.13
0.87
0.88
1.14
1.23
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
99
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
96
99
96
99
94
99
98
99
98
cUL Listed
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
UL Type CC
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
13
10
10
10
10
10
10
10
15
10
10
10
18
10
10
11
23
10
10
10
13
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
50.0/10
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
T12 Magnetic
FE15T8
System Watts
109
107
92
91
103
101
85
84
94
92
77
76
87
86
71
71
89
88
74
73
61
61
51
51
48
48
41
40
91
90
76
71
T12 Electronic
& High Output
F32T8/25W
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
Programmed
Start Dimming
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White
Yellow
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
• UL 55C Ambient Temperature rating
T8 Instant Start
78627 – GE432MAX-N/ULTRA (replaces 71727)
Ballasts
gelighting.com
RoHS Compliant
Sign
Compact
Fluorescent
10-19
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
71423 – GE432MAX-N+
UltraMax® Instant Start Multi-Voltage High-Efficiency
4 or 3 – F32T8 120 to 277 “N+” 1.0 BF UltraMax®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal – High
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing ST – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Yellow
Blue and Red
White and Black
Black
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
71423
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• Cold temperature -22°F Minimum Starting Temperature
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
2.4 in (61 mm)
1.6 in (40 mm)
8.9 in (226 mm)
1.7 in (43 mm)
0.3 in (8 mm)
2.16 lbs
Side
18 ft
18 AWG
Length (± 1 in)
47 in (1194 mm)
31 in (787 mm)
25 in (635 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
System Watts
Nom. Line Current
4
120
124
1.03 A
4
277
121
0.45 A
3
277
113
0.45 A
F32T8
3
120
97
0.81 A
4
120
119
1.00 A
4
277
117
0.44 A
3
120
92
0.77 A
F32T8/WM
3
277
92
0.35 A
4
120
114
0.95 A
4
277
96
0.36 A
3
120
89
0.74 A
F28T8
3
277
88
0.33 A
4
120
110
0.92 A
4
277
108
0.40 A
3
120
86
0.72 A
F25T12
3
277
86
0.32 A
Other compatible lamps: FE15T8, F25T8, F40T8, F17T8, F32T8/25W
Safety and performance
10-20
UL Type 1 Outdoor
UL Type CC
System Ballast Factor
1.00
1.00
1.15
0.97
1.00
1.00
0.99
0.99
1.00
1.00
0.99
0.99
0.96
0.96
0.97
0.97
UL Type HL
Ballast Efficacy Factor
0.81
0.83
1.02
1.00
0.84
0.86
1.07
1.08
0.88
1.04
1.12
1.13
0.87
0.89
1.13
1.13
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
97
99
99
98
99
97
99
97
99
96
99
97
99
96
UL Class P
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
cUL Listed
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
16
10
19
Min. Starting Temp (°F/°C)
-22/ -30
-22/ -30
-22/ -30
-22/ -30
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
See page E-1 for warranty information.
Ballasts
gelighting.com
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
6 or 5 – F32T8 120 to 277 “H” 1.18 BF UltraMax®
General characteristics
• Anti-Striation Control for better light quality, with no striations.
• Extreme 95% Electrical Efficiency
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature 22° F Minimum Starting Temperature
Dimensions
Electronic - High Efficiency Multivolt
Instant start
Parallel
(+/-)10 %
55° C (131° F)
70° C (158° F)
(1.18)
Active
A (20-24 decibels)
Metal
Anti-striation control, Universal voltage,
Inherent thermal protection
60 Hz
Order information
Pallet Pack
74118
DIY Pack
IP Pack
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
System Watts
221
215
197
192
205
200
182
178
187
184
166
164
178
176
159
157
122
121
107
106
231
225
Safety and performance
System Ballast Factor
1.18
1.18
1.25
1.25
1.18
1.18
1.23
1.23
1.18
1.18
1.20
1.20
1.18
1.18
1.16
1.16
1.17
1.17
1.24
1.24
1.18
1.18
UL Type 1 Outdoor
UL Type CC
UL Class P cUL Listed
UL Listed
UL Type HL RoHS Compliant
Ballast Efficacy Factor
0.53
0.55
0.63
0.65
0.58
0.59
0.68
0.69
0.63
0.64
0.72
0.73
0.66
0.67
0.73
0.74
0.96
0.97
1.16
1.17
0.51
0.52
Power Factor% (>=)
99
97
99
97
99
97
99
96
99
96
99
96
99
96
99
95
99
90
99
88
99
97
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
13
10
10
10
16
10
13
10
16
10
16
10
18
10
24
10
26
10
10
Min. Starting Temp (°F/°C)
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
0.0/-18
0.0/-18
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits 70C max case temp 5 yr warranty or 90C case temp 3 yr warranty
ANSI Standard C82.11-Cons 2002,
T12 Magnetic
Nom. Line Current
1.94 A
0.82 A
1.73 A
0.73 A
1.80 A
0.76 A
1.60 A
0.68 A
1.64 A
0.70 A
1.45 A
0.63 A
1.57 A
0.68 A
1.40 A
0.61 A
1.08 A
0.50 A
0.95 A
0.44 A
2.03 A
0.86 A
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
6
6
5
5
6
6
5
5
6
6
5
5
6
6
5
5
6
6
5
5
5
5
Programmed
Start Dimming
Electrical characteristics
Supply Current Frequency (MIN)
Wiring diagram – LFL -6H S60 – see example on Page 10-63
Case dimensions- Ref Drawing -A see page 10-65
Length (L)
11.75 in (299 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
11.1 in (283 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
3.10 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Red
34.0 in (864 mm)
Violet
25.0 in (635 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor High
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74117
T8 Instant Start
74117 – GE632MAX-H90
Sign
Compact
Fluorescent
10-21
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps
49766 – GE159MAX-N/ULTRA
UltraMax® Instant Start Multi-Voltage High-Efficiency
1 – F96T8 120 to 277 “N” .87 BF UltraMax®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
White
Red
Black
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
49766
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
78 in (1981 mm)
22 in (559 mm)
46 in (1168 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WM
F40T8
F96T8/WMP
# of Lamps
1
1
1
1
1
1
1
1
Line Volts
120
277
120
277
120
277
120
277
System Watts
54
53
51
51
38
38
Safety and performance
Nom. Line Current
0.46 A
0.21 A
0.43 A
0.20 A
0.32 A
0.15 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.87
0.87
0.87
Ballast Efficacy Factor
1.61
1.64
1.70
1.70
FCC – CLASS A Non-Consumer
49767 – GE259MAX-N/ULTRA
UltraMax® Instant Start Multi-Voltage High-Efficiency
2 or 1 – F96T8 120 to 277 “N” .87 BF UltraMax®
General characteristics
cUL Listed
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
UL Type CC
UL Listed
THD% (<=)
10
15
10
15
10
18
10
15
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
• Energy-saving high-efficiency instant-start electronic ballast (> 90%)
• Multi-voltage technology handles voltage from 120 to 277V
• Active Current Regulation regulates the output to each lamp with individual lamp inverter modules
• Anti-striation control for better light quality, with no striations
• UL Type CC Rating provides protection against arcing with F96T8 lamps only
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – High-Efficiency Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Anti-striation control, Auto-restart, Thermally protected
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
White
Red
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
49767
UL Class P
Power Factor% (>=)
99
95
99
95
99
95
99
95
Pallet Pack
DIY Pack
23954
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
22 in (559 mm)
46 in (1168 mm)
22 in (559 mm)
78 in (1981 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
2
120
2
277
1
120
F96T8
1
277
2
120
2
277
1
120
F96T8/WM
1
277
2
120
2
277
1
120
F96T8/WMP
1
277
2
120
2
277
1
120
F72T8
1
277
Other compatible lamps: F40T8
Safety and performance
10-22
System Watts
107
105
62
62
102
100
59
59
85
84
59
59
79
78
44
44
Nom. Line Current
0.91 A
0.40 A
0.53 A
0.24 A
0.87 A
0.38 A
0.50 A
0.23 A
0.78 A
0.32 A
0.50 A
0.23 A
0.72 A
0.29 A
0.39 A
0.17 A
UL Type 1 Outdoor
UL Type CC
System Ballast Factor
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.89
0.89
0.87
0.87
UL Type HL
Ballast Efficacy Factor
0.81
0.82
1.40
1.40
0.85
0.87
1.47
1.47
1.04
1.05
1.47
1.47
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
0.99
0.98
0.99
0.96
UL Class P
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
cUL Listed
UL Listed
THD% (<=)
10
15
10
20
10
15
10
20
10
15
10
20
10
13
10
20
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
50 / 10
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
See page E-1 for warranty information.
UltraMax® Instant Start Multi-Voltage 120–277V High-Efficiency
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps
UltraMax® Instant Start Multi-Voltage High-Efficiency
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Multi-Voltage Technology handles voltage from 120 to 277V
• Anti-Striation Control for better light quality, with no striations.
T8 Instant Start
73199 – GE259MAX-L/ULTRA
2 or 1 – F96T8 120 to 277 “L” .77 BF UltraMax®
Dimensions
General characteristics
Electrical characteristics
Supply Current Frequency (MIN)
50Hz/60 Hz
Order information
10 Pack
73199
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.09 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
78.0 in (1981 mm)
22.0 in (559 mm)
46.0 in (1168 mm)
22.0 in (559 mm)
Specifications by lamp and wattage
Lamp
F96T8/WM
F96T8/WMP
F72T8
Safety and performance
System Watts
95
94
59
59
93
91
58
58
89
87
54
54
Nom. Line Current
0.81 A
0.35 A
0.50 A
0.22 A
0.79 A
0.34 A
0.48 A
0.21 A
0.74 A
0.32 A
0.50 A
0.20 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.77
0.77
0.92
0.92
0.77
0.77
0.92
0.92
0.77
0.77
0.92
0.92
Ballast Efficacy Factor
0.81
0.82
1.56
1.56
0.83
0.85
1.59
1.59
0.87
0.89
1.70
1.70
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
99
99
97
99
98
99
97
99
98
99
96
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
0.0/ -18
0.0/ -18
0.0/ -18
0.0/ -18
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
T12 Electronic
& High Output
F40T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F96T8
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Programmed
Start Dimming
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Low (.77)
Active
Electronic
A (20-24 decibels)
Metal
Anti-striation control, Thermally protected, Universal voltage
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Circuit Type
Sound Rating
Enclosure Type
Additional Info
Ballasts
gelighting.com
RoHS Compliant
Application note:
T12 Magnetic
Use 30176 GE-286-HO-MV-N for 46 - 59W 4ft - 8ft Slimline Lamps for a High Ballast Factor (see page 10-51)
Sign
Compact
Fluorescent
10-23
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74093 – GE232MAX347-N
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
2 or 1 – F32T8 347V “N” .87 BF UltraMax®
General characteristics
Ballast Type
Multivolt
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Dimensions
Electronic - High Efficiency
Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74093
Pallet Pack
DIY Pack
IP Pack
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F25T12
# of Lamps
2
1
2
1
2
1
2
2
1
2
2
1
2
2
1
2
1
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
10-24
System Watts
53
34
50
32
46
30
42
41
26
35
30
20
25
24
16
44
29
Type 1 Outdoor
Nom. Line Current
0.15 A
0.10 A
0.15 A
0.09 A
0.14 A
0.09 A
Type HL
0.12 A
0.08 A
0.09 A
0.07 A
0.08 A
0.06 A
0.13 A
0.09 A
System Ballast Factor
0.87
1.02
0.86
1.02
0.84
1.01
0.84
0.88
1.03
0.88
0.83
0.98
0.83
0.76
0.88
0.89
1.08
Ballast Efficacy Factor
1.64
3.00
1.72
3.19
1.83
3.37
2.00
2.15
3.96
2.51
2.77
4.90
3.32
3.17
5.50
2.02
3.72
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
97
99
97
99
97
99
98
90
98
97
82
97
89
77
99
96
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.5
1.6
1.5
1.6
1.6
1.6
1.6
1.5
1.6
1.6
1.6
1.6
1.6
1.7
1.6
1.5
THD% (<=)
5
8
5
8
6
10
6
6
24
6
10
47
10
32
69
6
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74094 – GE332MAX347-N
UltraMax® 347V High-Efficiency
3 or 2 – F32T8 347V “N” .87 BF UltraMax®
Dimensions
General characteristics
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
Safety and performance
System Watts
79
60
75
57
70
53
63
62
48
53
43
34
36
33
25
65
50
Type 1 Outdoor
Nom. Line Current
0.23 A
0.17 A
0.22 A
0.17 A
0.20 A
0.15 A
Type HL
0.18 A
0.14 A
0.13 A
0.11 A
0.10 A
0.08 A
0.19 A
0.15 A
System Ballast Factor
0.87
0.98
0.86
0.96
0.84
0.94
0.84
0.88
0.99
0.88
0.84
0.94
0.84
0.76
0.85
0.89
1.01
Ballast Efficacy Factor
1.10
1.63
1.15
1.68
1.20
1.77
1.33
1.42
2.06
1.66
1.95
2.76
2.33
2.30
3.40
1.37
2.02
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
98
91
98
97
89
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.5
1.6
1.5
16.0
1.5
1.6
1.6
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5
THD% (<=)
5
5
5
6
4
6
4
5
6
5
7
29
7
13
46
5
6
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
T12 Electronic
& High Output
F25T12
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
T5 Electronic
Programmed Start
F32T8/WM
# of Lamps
3
2
3
2
3
2
3
3
2
3
3
2
3
3
2
3
2
Programmed
Start Dimming
Order information
Wiring diagram - LFL 1C – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74094
T8 Instant Start
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-25
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74095 – GE432MAX347-N
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
4 or 3 – F32T8 347V “N” .87 BF UltraMax®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74095
Pallet Pack
DIY Pack
IP Pack
Wiring diagram - LFL 1D – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Yellow
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
31.0 in (787 mm)
25.0 in (635 mm)
47.0 in (1194 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F25T12
# of Lamps
4
3
4
3
4
3
3
4
3
4
4
3
4
4
3
4
3
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
10-26
System Watts
106
87
100
83
93
77
84
83
69
71
58
48
50
46
38
88
73
Type 1 Outdoor
Nom. Line Current
0.30 A
0.25 A
0.29 A
0.24 A
0.27 A
0.22 A
Type HL
0.24 A
0.20 A
0.17 A
0.14 A
0.14 A
0.11 A
0.25 A
0.21 A
System Ballast Factor
0.88
0.94
0.86
0.92
0.84
0.90
0.84
0.88
0.95
0.88
0.83
0.90
0.83
0.80
0.82
0.88
0.96
Ballast Efficacy Factor
0.83
1.08
0.86
1.11
0.90
1.17
1.00
1.06
1.38
1.24
1.43
1.88
1.66
1.74
2.16
1.00
1.32
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
98
99
98
97
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.6
1.5
1.5
1.6
1.5
1.6
1.6
1.5
1.6
1.6
1.5
1.6
1.5
1.5
1.6
1.5
THD% (<=)
5
5
5
6
5
6
5
6
7
6
10
12
10
15
17
6
7
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60./16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74096 – GE232MAX347-L
UltraMax® 347V High-Efficiency
2 or 1 – F32T8 347V “L” .77 BF UltraMax®
General characteristics
Dimensions
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Low (.77)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
Safety and performance
System Watts
48
30
45
29
42
27
37
37
24
31
27
18
23
22
15
39
25
Type 1 Outdoor
Nom. Line Current
0.14 A
0.10 A
13.00 A
0.10 A
0.12 A
0.09 A
0.11 A
0.09 A
0.09 A
0.08 A
0.08 A
0.06 A
0.11 A
0.09 A
Type HL
System Ballast Factor
0.77
0.90
0.77
0.89
0.74
0.87
0.74
0.78
0.91
0.78
0.74
0.86
0.74
0.67
0.77
0.77
0.91
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
74097 – GE332MAX347-L
Power Factor% (>=)
99
87
99
86
98
83
98
97
77
97
84
68
84
79
66
98
80
Crest Factor (<=)
1.6
1.5
1.6
1.5
1.6
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.7
1.7
1.6
1.6
ANSI - C62.41 - 1991
THD% (<=)
5
37
6
39
7
41
7
15
46
15
47
53
47
54
56
7
42
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
3 or 2 – F32T8 347V “L” .77 BF UltraMax®
Dimensions
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Low (.77)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
60 Hz
Order information
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Sign
Supply Current Frequency (MIN)
Wiring diagram - LFL 1C – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T12 Magnetic
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74097
Ballast Efficacy Factor
1.60
3.00
1.71
3.07
1.76
3.22
2.00
2.11
3.79
2.52
2.74
4.78
3.22
3.05
5.13
1.97
3.64
T12 Electronic
& High Output
F25T12
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
T5 Electronic
Programmed Start
F32T8/WM
F28T8
# of Lamps
2
1
2
1
2
1
2
2
1
2
2
1
2
2
1
2
1
Programmed
Start Dimming
Order information
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74096
T8 Instant Start
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
FE15T8
F25T12
Safety and performance
System Watts
71
55
68
52
63
48
55
56
43
47
40
31
35
30
23
58
46
Type 1 Outdoor
See page E-1 for warranty information.
Nom. Line Current
0.21 A
0.16 A
0.20 A
0.15 A
0.18 A
0.14 A
Type HL
0.16 A
0.13A
0.12 A
0.10 A
0.09 A
0.07 A
0.17 A
0.13 A
System Ballast Factor
0.77
0.86
0.76
0.85
0.74
0.82
0.73
0.78
0.86
0.78
0.74
0.82
0.74
0.67
0.74
0.77
0.87
Ballast Efficacy Factor
1.08
1.56
1.12
1.63
1.17
1.71
1.33
1.39
2.00
1.66
1.85
2.65
2.11
2.23
3.22
1.33
1.89
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
99
99
99
99
99
99
99
98
99
98
89
98
96
93
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.5
RoHS Compliant
THD% (<=)
4
5
5
6
5
6
5
5
7
5
9
38
9
13
19
5
7
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
10-27
HID Electronic &
Electromagnetic
F17T8
F17T8/WM
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Compact
Fluorescent
F32T8
# of Lamps
3
2
3
2
3
2
3
3
2
3
3
2
3
3
2
3
2
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74098 – GE432MAX347-L
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
4 or 3 – F32T8 347V “L” .77 BF UltraMax®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Low (.77)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74098
Pallet Pack
DIY Pack
IP Pack
Wiring diagram - LFL 1D – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Yellow
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
(± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
31.0 in (787 mm)
25.0 in (635 mm)
47.0 in (1194 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F25T12
# of Lamps
4
3
4
3
4
3
3
4
3
4
4
3
4
4
3
4
3
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
10-28
System Watts
96
79
90
73
84
69
74
74
61
63
45
36
38
42
35
78
65
Type 1 Outdoor
Nom. Line Current
0.28 A
0.23 A
0.26 A
0.21 A
0.24 A
0.20 A
Type HL
0.21 A
0.18 A
0.13 A
0.11 A
0.12 A
0.11 A
0.23 A
0.19 A
System Ballast Factor
0.77
0.84
0.76
0.82
0.74
0.81
0.74
0.78
0.85
0.78
0.74
0.80
0.74
0.68
0.73
0.77
0.84
Ballast Efficacy Factor
0.80
1.06
0.84
1.12
0.88
1.17
1.00
1.05
1.39
1.24
1.64
2.22
1.95
1.62
2.09
0.99
1.29
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
100
99
99
99
99
99
99
99
99
98
92
98
97
91
100
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.5
1.5
THD% (<=)
6
7
7
8
7
8
7
7
9
7
13
33
13
15
37
7
8
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
2 or 1 – F32T8 347V “H” 1.18 BF UltraMax®
General characteristics
Dimensions
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
74110
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F40T8
Safety and performance
System Watts
70
44
67
42
63
39
56
55
36
47
37
23
31
30
19
53
61
39
Type 1 Outdoor
Nom. Line Current
0.20 A
0.13 A
0.19 A
0.12 A
0.12 A
0.12 A
Type HL
0.16 A
0.11 A
0.11 A
0.08 A
0.09 A
0.07 A
0.16 A
0.18 A
0.12 A
System Ballast Factor
1.18
1.32
1.15
0.29
1.30
1.30
1.12
1.16
1.32
1.16
1.10
1.25
1.10
1.00
1.15
1.24
1.23
1.45
Ballast Efficacy Factor
1.69
3.00
1.72
0.69
2.06
3.33
2.00
2.11
3.67
2.47
2.97
5.43
3.55
3.33
6.05
2.34
2.02
3.72
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
High Temperature Rated: Suitable for high temperature applications
Power Factor% (>=)
99
98
99
98
95
95
99
99
99
98
97
87
97
94
82
99
99
95
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.5
1.6
1.5
1.5
1.5
1.6
1.6
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.5
1.6
1.5
THD% (<=)
4
7
5
7
17
17
5
5
30
5
12
52
12
30
55
5
5
20
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
T12 Electronic
& High Output
F25T12
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
T5 Electronic
Programmed Start
F32T8/WM
F28T8
F32T8/25W
# of Lamps
2
1
2
1
2
1
2
2
1
2
2
1
2
2
1
1
2
1
Programmed
Start Dimming
Order information
Wiring diagram - LFL 1B – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74109
T8 Instant Start
74109 – GE232MAX347-H
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-29
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74111 – GE332MAX347-H
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
UltraMax® 347V High-Efficiency
3 – F32T8 347V “H” 1.18 BF UltraMax®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74111
Pallet Pack
74112
DIY Pack
IP Pack
Wiring diagram - LFL 1C – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F40T8
F25T12
# of Lamps
3
2
3
2
3
2
3
3
2
3
3
2
3
3
2
2
3
2
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
System Watts
105
79
100
76
93
71
85
82
62
70
60
44
52
46
36
99
89
68
Type 1 Outdoor
Nom. Line Current
0.30 A
0.23 A
0.29 A
0.22 A
0.27 A
0.20 A
Type HL
0.24 A
0.18 A
0.17 A
0.13 A
0.14 A
0.11 A
0.27 A
0.26 A
0.20 A
System Ballast Factor
1.18
1.29
1.15
1.27
1.13
1.26
1.13
1.17
1.30
1.17
1.10
1.22
1.10
1.00
1.11
1.28
1.24
1.40
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
High Temperature Rated: Suitable for high temperature applications
10-30
Ballast Efficacy Factor
1.12
1.63
1.15
1.67
1.22
1.77
1.33
1.43
2.10
1.67
1.83
2.77
2.12
2.17
3.08
1.29
1.39
2.06
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
98
99
98
91
99
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.6
1.6
1.6
1.6
1.5
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
THD% (<=)
5
6
5
6
6
7
6
6
9
6
10
13
10
12
33
6
6
8
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
See page E-1 for warranty information.
UltraMax® 347V High-Efficiency
T8 Instant Start Ballasts
74113 – GE432MAX347-H
UltraMax® 347V High-Efficiency
4 – F32T8 347V “H” 1.18 BF UltraMax®
General characteristics
Dimensions
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
31.0 in (787 mm)
31.0 in (787 mm)
25.0 in (635 mm)
47.0 in (1194 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F40T8
Safety and performance
System Watts
137
144
134
111
126
104
113
111
92
96
78
66
68
61
51
147
121
101
Type 1 Outdoor
Nom. Line Current
0.39 A
0.33 A
0.39 A
0.32 A
0.36 A
0.30 A
Type HL
0.32 A
0.27 A
0.23 A
0.19 A
0.18 A
0.15 A
0.41 A
0.35 A
0.29 A
System Ballast Factor
1.18
1.25
1.15
1.23
1.13
1.21
1.12
1.16
1.26
1.16
1.10
1.18
1.10
1.00
1.06
1.33
1.23
1.33
Ballast Efficacy Factor
0.86
0.87
0.86
1.11
0.90
1.16
0.99
1.05
1.37
1.21
1.41
1.79
1.62
1.64
2.08
0.90
1.02
1.32
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
High Temperature Rated: Suitable for high temperature applications
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
98
99
98
97
99
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.7
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.7
1.6
1.7
1.7
1.7
1.6
1.6
1.6
THD% (<=)
7
9
6
8
7
8
7
8
9
8
10
11
10
13
15
7
7
8
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
T12 Electronic
& High Output
F25T12
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
T5 Electronic
Programmed Start
F32T8/WM
F28T8
F32T8/25W
# of Lamps
4
3
4
3
4
3
4
4
3
4
4
3
4
4
3
3
4
3
Programmed
Start Dimming
Pallet Pack
74114
Wiring diagram - LFL 1D – see example on Page 10-62
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
White
Yellow
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74113
T8 Instant Start
• Energy saving high efficiency instant start electronic ballast (> 90%)
• Instant start ballast for long lamp starting cycles and low initial cost
• Anti-Striation Control for better light quality, with no striations.
• Cold temperature -20F Minimum Starting Temperature
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-31
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
73233 – GE232MAX90-S60
• Bi-Level Switching 100 to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
UltraMax® Bi-Level Dimming
Instant Start High-Efficiency
2 or 1 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 100/60% step dim
Dimensions
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Wiring diagram - LFL -2H S60– see example on Page 10-64
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Red
34.0 in (864 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
Electronic - Dimming
Continuous
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
No PCBs, Anti-striation control
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
73233
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
# of Lamps
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
Safety and performance
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
UL Type 1 Outdoor
UL Type CC
10-32
System Watts
75
74
44
44
47
47
40
40
69
68
43
43
43
43
39
39
64
63
43
43
40
40
37
37
59
57
43
43
36
36
34
34
42
42
38
38
27
27
26
26
55
55
40
40
Nom. Line Current
0.63 A
0.27 A
0.37 A
0.17 A
0.39 A
0.18 A
0.34 A
0.15 A
0.58 A
0.16 A
0.36 A
0.16 A
0.36 A
0.16 A
0.33 A
0.15 A
0.53 A
0.23 A
0.36 A
0.16 A
0.33 A
0.15 A
0.31 A
0.14 A
0.49 A
0.21 A
0.36 A
0.16 A
0.31 A
0.14 A
0.29 A
0.13 A
0.35 A
0.16 A
0.32 A
0.14 A
0.23 A
0.11 A
0.21 A
0.10 A
0.43 A
0.20 A
0.34 A
0.15 A
System Ballast
Factor
1.18
1.18
0.71
0.71
1.38
1.38
1.26
1.26
1.18
0.74
0.74
0.74
1.37
1.37
1.28
1.28
1.18
1.18
0.76
0.76
1.35
1.35
1.32
1.32
1.18
1.18
0.78
0.78
1.35
1.35
1.33
1.33
1.17
1.17
1.11
1.11
1.37
1.37
1.36
1.36
1.28
1.28
1.13
1.13
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
1.57
1.59
1.61
1.61
2.94
2.94
3.15
3.15
1.71
1.09
1.72
1.72
3.19
3.19
3.28
3.28
1.84
1.87
1.77
1.77
3.38
3.38
3.57
3.57
2.00
2.07
1.81
1.81
3.75
3.75
3.91
3.91
2.79
2.79
2.92
2.92
5.07
5.07
5.23
5.24
2.33
2.33
2.82
2.82
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
94
99
94
99
96
99
96
99
96
99
93
99
96
99
93
99
96
99
93
99
95
99
93
99
96
99
96
99
92
99
92
99
97
99
96
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.4
1.4
THD% (<=)
10
10
10
17
10
15
10
18
10
17
10
17
10
17
10
18
10
13
10
17
10
18
10
19
10
16
10
17
10
19
10
22
10
17
10
18
11
25
12
30
10
13
10
18
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
See page E-1 for warranty information.
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
73231 – GE332MAX90-S60
UltraMax® Bi-Level Dimming
Instant Start High-Efficiency
3 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 100/60% step dim
Dimensions
General characteristics
Wiring diagram - LFL -3H S60 – see example on Page 10-64
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635mm)
Blue
34.0 in (864mm)
Red
34.0 in (864mm)
White
25.0 in (635mm)
Yellow
41.0 in (1041 mm)
Electronic - Dimming
Step dimming
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
Metal
Anti-striation control, Universal voltage,
Inherent thermal protection
60 Hz
Order information
10 Pack
73231
Pallet Pack
DIY Pack
IP Pack
Programmed
Start Dimming
Electrical characteristics
Supply Current Frequency (MIN)
T8 Programmed
Start
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Enclosure Type
Additional Info
T8 Instant Start
• Bi-Level Switching 100 to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
Specifications by lamp and wattage
F32T8
F32T8/25W
F40T8
Safety and performance
UL Type 1 Outdoor
Nom. Line Current
0.94 A
0.40 A
0.55 A
0.25 A
0.72 A
0.32 A
0.51 A
0.23 A
0.86 A
0.37 A
0.55 A
0.23 A
0.66 A
0.29 A
0.52 A
0.24 A
0.79 A
0.34 A
0.56 A
0.24 A
0.61 A
0.27 A
0.53 A
0.24 A
0.77 A
0.32 A
0.56 A
0.25 A
0.56 A
0.25 A
0.53 A
0.24 A
0.52 A
0.23 A
0.50 A
0.22 A
0.40 A
0.19 A
0.40 A
0.18 A
0.85 A
0.37 A
0.51 A
0.23 A
System Ballast
Factor
1.18
1.18
0.71
0.71
1.29
1.29
0.99
0.99
1.18
1.18
0.75
0.75
1.26
1.26
1.05
1.05
1.18
1.18
0.75
0.75
1.26
1.26
1.05
1.05
1.18
1.18
0.80
0.80
1.26
1.26
1.05
1.05
1.15
1.15
1.14
1.14
1.27
1.25
1.25
1.25
1.22
1.22
0.68
0.68
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
1.04
1.07
1.08
1.08
1.50
1.52
1.62
1.62
1.15
1.17
1.14
1.21
1.59
1.62
1.67
1.67
1.24
1.27
1.14
1.15
1.75
1.77
1.64
1.67
1.30
1.33
1.19
1.21
1.88
1.91
1.64
1.67
1.85
1.89
1.93
1.97
2.65
2.60
2.66
2.66
1.20
1.22
1.11
1.11
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
97
99
96
99
96
99
93
99
96
99
93
99
96
99
93
99
96
99
93
99
96
99
93
99
96
99
96
99
94
99
94
99
98
99
96
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
17
10
13
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
10
18
10
16
10
17
10
16
10
17
10
17
10
17
10
19
10
19
10
10
10
16
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
Compact
Fluorescent
UL Type CC
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
10-33
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
System Watts
113
110
66
66
86
85
61
61
103
101
66
62
79
78
63
63
95
93
66
65
72
71
64
63
91
89
67
66
67
66
64
63
62
61
59
58
48
48
47
47
102
100
61
61
Sign
F17T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T12 Magnetic
F28T8
# of Lamps
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
2
2
2
2
T12 Electronic
& High Output
F32T8/WM
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
T5 Electronic
Programmed Start
Lamp
Ballasts
gelighting.com
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
73229 – GE432MAX90-S60
• Bi-Level Switching 100 to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
UltraMax® Bi-Level Dimming
Instant Start High-Efficiency
4 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 100/60% step dim
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Enclosure Type
Additional Info
Dimensions
Electronic - Dimming
Step dimming
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
Metal
Anti-striation control, Universal voltage,
Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
Wiring diagram - LFL -4H S60 – see example on Page 10-63
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting WireGauge
18 AWG
Lead lengths Qty Exit
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Red
34.0 in (864 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
60 Hz
Order information
10 Pack
73231
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
# of Lamps
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
3
3
3
3
Safety and performance
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
UL Type 1 Outdoor
UL Type CC
10-34
System Watts
149
146
88
87
119
116
75
75
136
133
83
83
113
112
71
71
127
125
78
78
103
102
68
68
116
114
75
75
96
95
66
66
81
80
64
64
62
62
59
59
146
143
84
83
Nom. Line Current
1.25 A
0.54 A
0.74 A
0.34 A
1.02 A
0.46 A
0.63 A
0.28 A
1.14 A
0.49 A
0.70 A
0.31 A
0.95 A
0.41 A
0.59 A
0.27 A
1.07 A
0.48 A
0.65 A
0.29 A
0.86 A
0.38 A
0.26 A
0.26 A
0.96 A
0.43 A
0.63 A
0.28 A
0.80 A
0.35 A
0.55 A
0.49 A
0.69 A
0.32 A
0.54 A
0.25 A
0.58 A
0.24 A
0.49 A
0.23 A
1.22 A
0.53 A
0.70 A
0.31 A
System Ballast
Factor
1.18
0.71
0.71
0.71
1.28
1.28
0.78
0.78
0.73
1.18
0.73
0.73
1.25
1.25
0.79
0.79
1.18
1.18
0.74
0.74
1.24
1.24
0.80
0.80
1.18
1.18
0.75
0.75
1.24
1.24
0.80
0.80
1.17
1.17
0.95
0.95
1.25
1.25
1.24
1.24
1.22
1.22
0.66
0.66
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
0.79
0.49
0.81
0.82
1.08
1.10
1.04
1.04
0.54
0.89
0.88
0.88
1.11
1.12
1.11
1.11
0.93
0.94
0.95
0.95
1.20
1.22
1.18
1.18
1.02
1.04
1.00
1.00
1.29
1.31
1.21
1.21
1.44
1.46
1.48
1.48
2.02
2.02
2.10
2.10
0.84
0.85
0.79
0.80
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
97
99
94
99
96
99
93
99
96
99
93
99
96
99
93
99
96
99
93
99
97
99
93
99
96
99
94
99
95
99
93
99
97
99
96
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
17
10
13
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
10
18
10
16
10
17
10
16
10
17
10
14
10
17
10
18
10
18
10
10
10
14
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
See page E-1 for warranty information.
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
71497 – GE632MAX-H90-S60
UltraMax® Bi-Level Dimming
Instant Start High-Efficiency
T8 Instant Start
• Bi-Level Switching 100 to 60%
• Extreme 95% Electrical Efficiency
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Cold temperature -20F Minimum Starting Temperature
6, 5, 4 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 100/60% step dim
General characteristics
Dimensions
Wiring diagram - LFL -6H S60 – see example on Page 10-63
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
11.75 in (299 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
11.1 in (283 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
3.10 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Gray
25.0 in (635 mm)
Red
34.0 in (864 mm)
Yellow
41.0 in (1041 mm)
White
25.0 in (635 mm)
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
71497
Pallet Pack
DIY Pack
IP Pack
Programmed
Start Dimming
Electronic - Dimming
Step dimming
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
Anti-striation control, Universal voltage,
Inherent thermal protection
T8 Programmed
Start
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Ballasts
gelighting.com
Specifications by lamp and wattage
F32T8
F32T8/25W
F25T8
F40T8
System Ballast
Factor
1.18
1.18
0.71
0.71
1.25
1.25
0.77
0.77
1.18
1.18
0.71
0.71
1.23
1.23
0.82
0.82
1.18
1.18
0.74
0.74
1.20
1.20
Ballast Efficacy
Factor
0.53
0.55
0.53
0.54
0.63
0.65
0.63
0.63
0.58
0.59
0.55
0.56
0.68
0.69
0.68
0.68
0.63
0.64
0.60
0.61
0.72
0.73
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
97
99
94
99
96
99
93
99
96
99
93
99
96
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
1
17
10
13
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
Min. Starting Temp (°F/°C)
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
118
178
176
122
121
159
157
118
117
122
121
104
103
107
106
98
98
231
225
131
130
0.48 A
1.57 A
0.68 A
1.03 A
0.49 A
1.40 A
0.61 A
1.01 A
0.48 A
1.08 A
0.50 A
0.88 A
0.43 A
0.95 A
0.44 A
0.83 A
0.42 A
2.03 A
0.86 A
1.12 A
0.53 A
0.86
1.18
1.18
0.70
0.70
1.16
1.16
0.87
0.87
1.17
1.17
1.03
1.03
1.24
1.24
1.16
1.16
1.18
1.18
0.64
0.64
0.73
0.66
0.67
0.57
0.58
0.73
0.74
0.74
0.74
0.96
0.97
0.99
1.00
1.16
1.17
1.18
1.18
0.51
0.52
0.49
0.49
93
99
96
99
93
99
95
99
93
99
90
99
89
99
88
99
88
99
97
99
94
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
18
10
16
10
17
10
18
10
20
10
24
10
24
10
26
10
26
10
10
10
17
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
0.0/-18
0.0/-18
0.0/-18
0.0/-18
UL Type 1 Outdoor
UL Type CC
UL Type HL ANSI - C82.11 Cons 2002,
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
RoHS Compliant
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
10-35
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Nom. Line Current
1.94 A
0.82 A
1.13 A
0.53 A
1.73 A
0.73 A
1.04 A
0.49 A
1.80 A
0.76 A
1.09 A
0.51 A
1.60 A
0.68 A
1.03 A
0.49 A
1.64 A
0.70 A
1.05 A
0.50 A
1.45 A
0.63 A
Compact
Fluorescent
Safety and performance
System Watts
221
215
133
132
197
192
123
122
205
200
128
127
182
178
121
120
187
184
123
122
166
164
Sign
F17T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T12 Magnetic
F28T8
# of Lamps
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
5
5
5
5
T12 Electronic
& High Output
F32T8/WM
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
T5 Electronic
Programmed Start
Lamp
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
73234 – GE232MAX90-V60
• Load Shed Variable Dimming 0-10V 100% to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
UltraMax® Load Shed Dimming
Instant Start High-Efficiency
2 or 1 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 0-10V 100-60% dim
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature(MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Dimensions
Wiring diagram - LFL -2H V60 – see example on Page 10-64
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Gray
25.0 in (635 mm)
Red
34.0 in (864 mm)
Violet
25.0 in (635 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
Electronic - Dimming
Continuous
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
No PCBs, Anti-striation control
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
73234
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
query
query
query
query
100%
100%
60%
60%
100%
100%
60%
60%
# of Lamps
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
1
1
1
Safety and performance
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
UL Type 1 Outdoor
UL Type CC
10-36
System Watts
75
74
44
43
47
47
45
45
69
68
46
46
43
43
42
42
63
62
46
46
39
39
38
38
59
57
46
46
36
36
36
36
42
42
41
41
56
55
46
46
Nom. Line Current
0.63 A
0.28 A
0.36 A
0.17 A
0.39 A
0.18 A
0.38 A
0.18 A
0.57 A
0.25 A
0.39 A
0.18 A
0.36 A
0.17 A
0.35 A
0.17 A
0.53 A
0.24 A
0.39 A
0.18 A
0.33 A
0.16 A
0.32 A
0.16 A
0.48 A
0.22 A
0.38 A
0.18 A
0.30 A
0.15 A
0.30 A
0.15 A
0.35 A
0.17 A
0.34 A
0.16 A
0.46 A
0.21 A
0.39 A
0.18 A
System Ballast
Factor
1.18
1.18
0.71
0.71
1.38
1.38
1.34
1.34
1.18
1.18
0.77
0.77
1.37
1.37
1.36
1.36
1.18
1.18
0.79
0.79
1.35
1.35
1.34
1.34
1.18
1.18
0.81
0.81
1.35
1.35
1.35
1.35
1.17
1.17
1.16
1.16
1.28
1.28
1.18
1.18
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
1.57
1.59
1.61
1.65
2.94
2.94
2.98
2.98
1.71
1.74
1.67
1.67
3.19
3.19
3.24
3.24
1.87
1.90
1.72
1.72
3.46
3.46
3.53
3.53
2.00
2.07
1.76
1.76
3.75
3.75
3.75
3.75
2.79
2.79
2.83
2.83
2.29
2.33
2.57
2.57
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
96
99
94
99
92
99
92
99
96
99
92
99
92
99
91
99
95
99
92
99
90
99
90
99
94
99
92
99
88
99
88
99
90
99
90
99
94
99
92
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
18
10
18
10
18
10
11
10
18
10
20
10
21
10
13
10
19
10
26
10
26
10
16
10
19
10
26
10
26
10
24
10
24
10
15
10
18
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
See page E-1 for warranty information.
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
• Load Shed Variable Dimming 0-10V 100% to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
UltraMax® Load Shed Dimming
Instant Start High-Efficiency
3 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 0-10V 100-60% dim
Electrical characteristics
60 Hz
Order information
10 Pack
73232
Pallet Pack
DIY Pack
IP Pack
Programmed
Start Dimming
Wiring diagram - LFL -3H V60 – see example on Page 10-64
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Blue
34.0 in (864 mm)
Violet
25.0 in (635 mm)
Red
34.0 in (864 mm)
Yellow
41.0 in (1041 mm)
Black
25.0 in (635 mm)
White
25.0 in (635 mm)
Gray
25.0 in (635 mm)
Electronic - Dimming
Continuous
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
No PCBs, Anti-striation control
Supply Current Frequency (MIN)
T8 Programmed
Start
Dimensions
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
T8 Instant Start
73232 – GE332MAX90-V60
F32T8
F32T8/25W
F40T8
UL Type 1 Outdoor
UL Type CC
System Ballast
Factor
1.18
1.18
0.71
0.71
1.29
1.29
1.05
1.05
1.18
1.18
0.78
0.78
1.26
1.26
1.07
1.07
1.18
1.18
0.87
0.87
1.26
1.26
1.10
1.10
1.18
1.18
0.89
0.89
1.26
1.26
1.15
1.15
1.15
1.15
1.14
1.14
1.27
1.27
1.25
1.25
1.22
1.22
0.68
0.68
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
1.04
1.07
1.08
1.09
1.52
1.54
1.46
1.46
1.13
1.16
1.08
1.10
1.59
1.62
1.65
1.65
1.24
1.26
1.23
1.24
1.73
1.75
1.62
1.64
1.30
1.33
1.25
1.27
1.83
1.85
1.80
1.83
1.88
1.92
1.97
1.97
2.70
2.70
2.78
2.78
1.17
1.20
1.03
1.05
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
97
99
94
99
96
99
93
99
96
99
93
99
95
99
93
99
96
99
93
99
95
99
93
99
95
99
94
99
91
99
91
99
97
99
96
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
17
10
13
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
10
18
10
16
10
17
10
17
10
17
10
17
10
17
10
21
10
20
10
10
10
14
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
10-37
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Nom. Line Current
0.94 A
0.41 A
0.55 A
0.25 A
0.72 A
0.32 A
0.62 A
0.28 A
0.91 A
0.38 A
0.61 A
0.28 A
0.67 A
0.30 A
0.61 A
0.27 A
0.81 A
0.35 A
0.64 A
0.28 A
0.61 A
0.27 A
0.57 A
0.25 A
0.77 A
0.33 A
0.63 A
0.28 A
0.57 A
0.26 A
0.54 A
0.24 A
0.54 A
0.24 A
0.51 A
0.23 A
0.41 A
0.20 A
0.40 A
0.19 A
0.87 A
0.38 A
0.61 A
0.27 A
Compact
Fluorescent
Safety and performance
System Watts
113
110
66
65
85
84
72
72
104
102
72
71
79
78
65
65
95
94
71
70
73
72
68
67
91
89
71
70
69
68
64
63
61
60
58
58
47
47
45
45
104
102
66
65
Sign
F17T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T12 Magnetic
F28T8
# of Lamps
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
3
3
3
3
2
2
2
2
2
2
2
2
T12 Electronic
& High Output
F32T8/WM
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
T5 Electronic
Programmed Start
Specifications by lamp and wattage
Lamp
Ballasts
gelighting.com
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
73230 – GE432MAX90-V60
• Load Shed Variable Dimming 0-10V 100% to 60%
• Anti-Striation Control for better light quality, with no striations.
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -22F Minimum Starting Temperature
UltraMax® Load Shed Dimming
Instant Start High-Efficiency
4 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 0-10V 100-60% dim
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Dimensions
Electronic - Dimming
Continuous
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
No PCBs, Anti-striation control
Electrical characteristics
Supply Current Frequency (MIN)
Wiring diagram - LFL -4H V60 – see example on Page 10-63
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
9.5 in (241 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
8.9 in (226 mm)
Mount Width (X or F)
1.18 in (30 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
1.40 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Gray
25.0 in (635 mm)
Red
34.0 in (864 mm)
Violet
25.0 in (635 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
60 Hz
Order information
10 Pack
73230
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
# of Lamps
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
4
4
4
4
3
3
3
3
3
3
3
3
Safety and performance
Line Volts
120
277
120
277
277
120
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
UL Type 1 Outdoor
UL Type CC
10-38
System Watts
149
146
88
87
116
119
84
83
136
133
93
92
113
111
89
89
127
125
95
94
104
102
89
89
116
114
94
93
95
94
90
89
81
80
64
64
62
62
59
59
147
144
86
86
Nom. Line Current
1.25 A
0.54 A
0.74 A
0.34 A
0.46 A
1.02 A
0.70 A
0.32 A
1.14 A
0.49 A
0.78 A
0.35 A
0.95 A
0.42 A
0.75 A
0.34 A
1.07 A
0.48 A
0.79 A
0.36 A
0.86 A
0.38 A
0.74 A
0.34 A
0.96 A
0.43 A
0.79 A
0.36 A
0.80 A
0.36 A
0.75 A
0.34 A
0.69 A
0.32 A
0.54 A
0.25 A
0.58 A
0.24 A
0.49 A
0.23 A
1.22 A
0.53 A
0.72 A
0.33 A
System Ballast
Factor
1.18
1.18
0.71
0.71
1.28
1.28
0.89
0.89
0.73
1.18
0.77
0.77
1.25
1.25
0.91
0.91
1.18
1.18
0.87
0.87
1.24
1.24
1.18
1.18
1.18
1.18
0.87
0.87
1.24
1.24
1.22
1.22
1.17
1.17
0.95
0.95
1.25
1.25
1.24
1.24
1.22
1.22
0.66
0.66
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
0.79
0.81
0.81
0.82
1.10
1.08
1.06
1.07
0.54
0.89
0.83
0.84
1.11
1.13
1.02
1.02
0.93
0.94
0.92
0.93
1.19
1.22
1.33
1.33
1.02
1.04
0.93
0.94
1.31
1.32
1.36
1.37
1.44
1.46
1.48
1.48
2.02
2.02
2.10
2.10
0.83
0.85
0.77
0.77
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
96
99
99
93
99
97
99
94
99
96
99
93
99
96
99
93
99
95
99
93
99
96
99
93
99
94
99
93
99
96
99
94
99
95
99
93
99
97
99
96
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.4
1.4
1.4
1.4
THD% (<=)
10
10
10
17
13
10
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
10
18
10
16
10
17
10
16
10
17
10
14
10
17
10
18
10
18
10
10
10
14
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
See page E-1 for warranty information.
UltraMax® Bi-Level Dimming & Load Shed Dimming Instant Start High-Efficiency
T8 Instant Start Ballasts
• Load Shed Variable Dimming 0-10V 100% to 60%
• Anti-Striation Control for better light quality, with no striations.
• Extreme 95% Electrical Efficiency
• UL 55C Ambient Rating - HighTemperature Protection Circuit
• Multi-Voltage Technology handles voltage from 120 to 277V
• UL Type CC Rating provides protection against arcing in electrical devices.
• Cold temperature -20F Minimum Starting Temperature
UltraMax® Load Shed Dimming
Instant Start High-Efficiency
6 or 5 – F32T8 120 to 277 “H” 1.18 BF UltraMax® 0-10V 100-60% dim
Electrical characteristics
60 Hz
Order information
10 Pack
71731
Pallet Pack
DIY Pack
IP Pack
Programmed
Start Dimming
Wiring diagram - LFL -6H V60 – see example on Page 10-63
Case dimensions- Ref Drawing -A – see Page 10-65
Length (L)
11.75 in (299 mm)
Width (W)
1.7 in (43 mm)
Height (H)
1.18 in (30 mm)
Mounting dimensions
Mount Length (M)
11.1 in (283 mm)
Mount Slots (MS)
0.3 in (8 mm)
Weight
3.10 lbs
Exit Type
Side
Remote Mounting Distance to Lamp (F32T8)
18 ft
Remote Mounting Wire Gauge
18 AWG
Lead lengths
Length (± 1 in.)
Black
25.0 in (635 mm)
Blue
34.0 in (864 mm)
Gray
25.0 in (635 mm)
Red
34.0 in (864 mm)
Violet
25.0 in (635 mm)
White
25.0 in (635 mm)
Yellow
41.0 in (1041 mm)
Electronic - Dimming
Continuous
Instant start
Parallel
10 %
55° C (131° F)
70 °C (158 °F)
High (1.18)
Active
A (20-24 decibels)
Metal
Anti-striation control, Universal voltage, Inherent thermal
protection
Supply Current Frequency (MIN)
T8 Programmed
Start
Dimensions
General characteristics
Ballast Type
Dimming Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
T8 Instant Start
71731 – GE632MAX-H90-V60
F32T8
F32T8/25W
F25T8
F40T8
UL Type 1 Outdoor
UL Type CC
System Ballast
Factor
1.18
1.18
0.71
0.71
1.25
1.25
0.77
0.77
1.18
1.18
0.71
0.71
1.23
1.23
0.82
0.82
1.18
1.18
0.74
0.74
1.20
1.20
0.86
0.86
1.18
1.18
0.70
0.70
1.16
1.16
0.87
0.87
1.17
1.17
1.03
1.03
1.24
1.24
1.16
1.16
1.18
1.18
0.64
0.64
UL Type HL ANSI - C82.11 Cons 2002,
Ballast Efficacy
Factor
0.53
0.55
0.53
0.54
0.63
0.65
0.63
0.63
0.58
0.59
0.55
0.56
0.68
0.69
0.68
0.68
0.63
0.64
0.60
0.61
0.72
0.73
0.72
0.73
0.66
0.67
0.57
0.58
0.73
0.74
0.74
0.74
0.96
0.97
0.99
1.00
1.16
1.17
1.18
1.18
0.51
0.52
0.49
0.49
ANSI - C62.41 - 1991
High Temperature Rated: Suitable for high temperature applications
Power Factor % (>=)
99
97
99
94
99
97
99
93
99
97
99
94
99
96
99
93
99
96
99
93
99
96
99
93
99
96
99
93
99
95
99
93
99
90
99
89
99
88
99
88
99
97
99
94
RoHS Compliant
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
10
10
1
17
10
13
10
18
10
10
10
17
10
16
10
18
10
13
10
17
10
16
10
18
10
16
10
17
10
18
10
20
10
24
10
24
10
26
10
26
10
10
10
17
Min. Starting Temp (°F/°C)
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-20.0/-29
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
-20.0/-29
0.0/-18
0.0/-18
0.0/-18
0.0/-18
FCC – Part 18 (Class A) for EMI and RFI Non-Consumer Limits
cUL Listed
70C max case temp 5 yr warranty or 90C max case temp 3 yr warranty
10-39
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Nom. Line Current
1.94 A
0.82 A
1.13 A
0.53 A
1.73 A
0.73 A
1.04 A
0.49 A
1.80 A
0.76 A
1.09 A
0.51 A
1.60 A
0.68 A
1.03 A
0.49 A
1.64 A
0.70 A
1.05 A
0.50 A
1.45 A
0.63 A
1.01 A
0.48 A
1.57 A
0.68 A
1.03 A
0.49 A
1.40 A
0.61 A
1.01 A
0.48 A
1.08 A
0.50 A
0.88 A
0.43 A
0.95 A
0.44 A
0.83 A
0.42 A
2.03 A
0.86 A
1.12 A
0.53 A
Compact
Fluorescent
Safety and performance
System Watts
221
215
133
132
197
192
123
122
205
200
128
127
182
178
121
120
187
184
123
122
166
164
119
118
178
176
122
121
159
157
118
117
122
121
104
103
107
106
98
98
231
225
131
130
Sign
F17T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T12 Magnetic
F28T8
# of Lamps
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
6
6
6
6
5
5
5
5
5
5
5
5
T12 Electronic
& High Output
F32T8/WM
Light
Level
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
100%
100%
60%
60%
T5 Electronic
Programmed Start
Specifications by lamp and wattage
Lamp
Ballasts
gelighting.com
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72269 – GE-132-MV-N (replaces 30189)
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72269
Pallet Pack
72270 (replaces 30268)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
# of Lamps
1
1
1
1
1
1
1
1
1
1
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-40
System Watts
28
28
26
26
25
25
24
24
22
23
16
16
Nom. Line Current
0.23 A
0.10 A
0.22 A
0.10 A
0.21 A
0.09 A
0.00 A
0.00 A
0.19 A
0.09 A
0.14 A
0.07 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.87
0.88
0.88
0.88
0.88
0.88
0.88
0.93
0.93
0.92
0.92
Ballast Efficacy Factor
3.11
3.11
3.38
3.38
3.52
3.52
3.67
3.67
4.23
4.04
5.75
5.75
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
96
99
96
99
95
99
97
99
94
99
84
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.5
1.5
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
6
8
6
8
6
9
10
10
7
9
9
11
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
74803 – GE232MV-H (replaces 30198)
ProLine® T8 Multivolt 120V – 277V
2 or 1 – F32T8 120 to 277 “H” 1.18 BF Multivolt ProLine®
General characteristics
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High (1.18)
Active
A (20-24 decibels)
Anti-striation control, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74803
Pallet Pack
74804 (replaces 30275)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F28T8
F32T8/25W
F17T8
F40T8
Nom. Line Current
0.65 A
0.28 A
0.44 A
0.20 A
0.63 A
0.28 A
0.42 A
0.19 A
0.57 A
0.26 A
0.39 A
0.18 A
0.00 A
0.00 A
0.00 A
0.00 A
0.51 A
0.23 A
0.35 A
0.16 A
0.36 A
0.16 A
0.24 A
0.11 A
0.53 A
0.23 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
1.18
1.18
1.34
1.34
1.13
1.13
1.30
1.30
1.10
1.10
1.28
1.28
1.10
1.10
1.28
1.28
1.16
1.16
1.32
1.32
1.15
1.15
1.31
1.31
UL Type HL
Ballast Efficacy Factor
1.53
1.55
2.79
2.79
1.61
1.64
2.89
2.89
1.69
1.72
3.05
3.05
1.83
1.83
3.46
3.46
2.04
2.04
3.47
3.47
2.80
2.80
4.85
4.85
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
97
99
98
99
96
99
98
99
96
99
98
99
97
99
97
99
96
99
96
99
94
99
97
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.5
1.5
1.5
1.5
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
7
15
10
18
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
Safety and performance
System Watts
77
76
48
48
70
69
45
45
65
64
42
42
60
60
37
37
57
57
38
38
41
41
27
27
57
57
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8/WM
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
1
1
Programmed
Start Dimming
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-41
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72273 – GE-232-MV-L (replaces 30247)
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
2 or 1 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Low
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72273
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
F40T8
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-42
System Watts
51
50
32
32
47
47
30
30
43
43
28
28
40
40
25
25
40
40
25
25
28
28
18
19
39
39
Nom. Line Current
0.43 A
0.19 A
0.27 A
0.19 A
0.40 A
0.17 A
0.25 A
0.11 A
0.36 A
0.16 A
0.23 A
0.10 A
0.00 A
0.00 A
0.00 A
0.00 A
0.34 A
0.15 A
0.21 A
0.10 A
0.24 A
0.11 A
0.15 A
0.07 A
0.33 A
0.14 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.78
0.78
0.93
0.93
0.77
0.77
0.91
0.91
0.76
0.76
0.89
0.89
0.74
0.74
0.89
0.89
0.80
0.80
0.95
0.95
0.79
0.79
0.93
0.93
0.94
0.94
UL Type HL
Ballast Efficacy Factor
1.53
1.56
2.91
2.91
1.64
1.64
3.03
3.03
1.77
1.77
3.18
3.18
1.85
1.85
3.56
3.56
2.00
2.00
3.80
3.80
2.82
2.82
5.17
4.89
2.41
2.41
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
95
99
97
99
95
99
96
99
94
99
98
99
97
99
95
99
93
99
94
99
91
99
95
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
4
8
6
8
5
7
7
9
5
7
7
10
10
10
10
10
5
8
7
11
7
9
9
15
5
8
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
72275 – GE-232-MV-N (replaces 30191)
ProLine® T8 Multivolt 120V – 277V
2 or 1 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
72275
Pallet Pack
72276 (replaces 30269)
DIY Pack
72277 (replaces 97709)
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F32T8/25W
F17T8
F40T8
Nom. Line Current
0.48 A
0.20 A
0.30 A
0.13 A
0.44 A
0.19 A
0.28 A
0.12 A
0.39 A
0.17 A
0.26 A
0.11 A
0.00 A
0.00 A
0.00 A
0.00 A
0.37 A
0.16 A
0.23 A
0.11 A
0.26 A
0.12 A
0.17 A
0.08 A
0.37 A
0.16 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.88
0.88
1.08
1.08
0.86
0.87
1.05
1.05
0.83
0.83
1.02
1.02
0.83
0.83
1.02
1.02
0.90
0.91
1.08
1.08
0.88
0.88
1.05
1.05
1.08
1.08
UL Type HL
Ballast Efficacy Factor
1.54
1.60
3.09
3.09
1.62
1.71
3.18
3.18
1.77
1.77
3.29
3.29
1.93
1.93
3.64
3.64
2.05
2.07
3.86
3.86
2.84
2.84
5.25
5.00
2.45
2.51
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
98
99
97
99
97
99
96
99
97
99
95
99
97
99
98
99
97
99
95
99
95
99
92
99
96
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
4
9
5
8
4
8
6
8
4
8
6
9
10
10
10
10
5
7
7
9
6
9
8
14
5
8
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
Safety and performance
System Watts
57
55
35
35
53
51
33
33
47
47
31
31
43
43
28
28
44
44
28
28
31
31
20
21
44
43
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
1
1
Programmed
Start Dimming
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
White
Blue
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-43
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
74461 – GE332MV-H (replaces 30199)
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
3 or 2 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High (1.18)
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74461
Pallet Pack
74462 (replaces 30296)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
F40T8
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
2
2
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-44
System Watts
113
110
86
85
103
101
79
78
94
92
72
72
89
88
68
69
84
83
65
65
59
59
46
46
102
100
Nom. Line Current
0.95 A
0.41 A
0.79 A
0.34 A
0.91 A
0.39 A
0.73 A
0.32 A
0.84 A
0.36 A
0.67 A
0.30 A
0.00 A
0.00 A
0.00 A
0.00 A
0.75 A
0.33 A
0.61 A
0.26 A
0.52 A
0.24 A
0.43 A
0.20 A
0.95 A
0.41 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
1.15
1.15
1.27
1.27
1.11
1.11
1.22
1.22
1.10
1.10
1.20
1.20
1.07
1.07
1.20
1.20
1.14
1.14
1.14
1.14
1.13
1.13
1.24
1.24
Ballast Efficacy Factor
1.02
1.05
1.48
1.49
1.08
1.10
1.54
1.56
1.17
1.20
1.67
1.67
1.20
1.22
1.76
1.74
1.36
1.37
1.75
1.75
1.92
1.92
2.70
2.70
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
97
99
96
99
95
99
98
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
10
18
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
74459 – GE332MV-L (replaces 30255)
ProLine® T8 Multivolt 120V – 277V
3 or 2 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
Dimensions
General characteristics
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74459
Pallet Pack
74460 (replaces 30309)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F28T8
F32T8/25W
F17T8
F40T8
Nom. Line Current
0.70 A
0.31 A
0.55 A
0.24 A
0.62 A
0.27 A
0.50 A
0.22 A
0.57 A
0.25 A
0.46 A
0.20 A
0.00 A
0.00 A
0.00 A
0.00 A
0.52 A
0.23 A
0.42 A
0.19 A
0.36 A
0.16 A
0.30 A
0.14 A
0.63 A
0.27 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.78
0.78
0.87
0.87
0.75
0.75
0.83
0.83
0.75
0.75
0.83
0.83
0.74
0.74
0.83
0.83
0.77
0.77
0.86
0.86
0.77
0.77
0.85
0.85
Ballast Efficacy Factor
1.05
1.07
1.46
1.47
1.09
1.10
1.51
1.52
1.19
1.20
1.68
1.66
1.25
1.25
1.80
1.77
1.33
1.33
1.91
1.90
1.89
1.88
2.65
2.61
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
96
99
96
99
95
99
98
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
8
15
10
18
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
T12 Magnetic
Safety and performance
System Watts
74
73
60
59
69
68
55
55
63
63
50
50
59
59
46
47
58
58
45
45
41
41
32
33
69
68
T12 Electronic
& High Output
F25T8
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8/WM
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
2
2
Programmed
Start Dimming
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Low (.77)
Active
A (20-24 decibels)
Auto-restart, Thermally protected
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
Sign
Compact
Fluorescent
10-45
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
74456 – GE332MV-N (replaces 30192)
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
3 or 2 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74456
Pallet Pack
74457 (replaces 30270)
DIY Pack
74458 (replaces 97710)
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
F40T8
# of Lamps
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
2
2
2
2
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-46
System Watts
81
80
62
62
75
74
58
57
67
66
52
51
66
65
51
50
63
62
48
48
45
44
34
35
75
73
Nom. Line Current
0.73 A
0.32 A
0.56 A
0.26 A
0.68 A
0.30 A
0.52 A
0.23 A
0.60 A
0.26 A
0.46 A
0.29 A
0.00 A
0.00 A
0.00 A
0.00 A
0.57 A
0.25 A
0.43 A
0.19 A
0.40 A
0.18 A
0.33 A
0.15 A
0.67 A
0.29 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.87
0.96
0.96
0.83
0.83
0.92
0.92
0.82
0.82
0.87
0.87
0.80
0.80
0.87
0.87
0.86
0.86
0.94
0.94
0.86
0.86
0.92
0.92
Ballast Efficacy Factor
1.07
1.09
1.55
1.55
1.11
1.12
1.60
1.61
1.22
1.24
1.69
1.71
1.21
1.23
1.71
1.74
1.37
1.38
1.95
1.95
1.92
1.93
2.67
2.64
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
98
99
98
99
98
99
98
99
97
99
98
99
97
99
98
99
97
99
97
99
96
99
98
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
13
10
18
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
78629 – GE-432-MV-H (replaces 30219)
ProLine® T8 Multivolt 120V – 277V
4 or 3 – F32T8 120 to 277 “H” 1.15 BF Multivolt ProLine®
General characteristics
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
High
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
78629
Pallet Pack
78630 (replaces 30303)
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.2 in (30 mm)
8.9 in (226 mm)
1.7 in (43 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
31 in (787 mm)
47 in (1194 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
1.15
1.15
1.24
1.24
1.11
1.11
1.20
1.20
1.08
1.08
1.17
1.17
Ballast Efficacy Factor
0.79
0.82
1.01
1.03
0.82
0.83
1.07
1.09
0.88
0.90
1.14
1.15
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
98
99
98
99
97
99
98
99
97
99
98
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
8
15
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
RoHS Compliant
T12 Electronic
& High Output
Safety and performance
Nom. Line Current
1.35 A
0.57 A
1.13 A
0.49 A
1.25 A
0.54 A
1.00 A
0.45 A
1.13 A
0.48 A
0.94 A
0.41 A
1.30 A
0.57 A
T5 Electronic
Programmed Start
# of Lamps
Line Volts
System Watts
4
120
144
4
277
140
3
120
122
F32T8
3
277
120
4
120
135
4
277
133
3
120
112
F32T8/WM
3
277
110
4
120
122
4
277
120
3
120
102
F28T8
3
277
101
3
120
145
F40T8
3
277
141
Other compatible lamps: F25T8, F17T8, F32T8/25W
Programmed
Start Dimming
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
White and Black
Red
Yellow
Blue
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-47
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
74466 – GE-432-MV-L (replaces 30262)
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
4 or 3 – F32T8 120 to 277 “L” .77 BF Multivolt ProLine®
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Low (.77)
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue
Red
Yellow
White
Black
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74466
Pallet Pack
74467 (replaces 30310)
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
31 in (787 mm)
31 in (787 mm)
47 in (1194 mm)
25 in (635 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F17T8
F40T8
# of Lamps
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
3
3
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-48
System Watts
100
98
87
86
95
93
79
78
86
85
73
72
77
77
65
65
78
77
66
65
55
55
46
46
102
100
Nom. Line Current
0.95 A
0.41 A
0.80 A
0.35 A
0.84 A
0.36 A
0.73 A
0.32 A
0.77 A
0.33 A
0.67 A
0.29 A
0.00 A
0.00 A
0.00 A
0.00 A
0.69 A
0.31 A
0.61 A
0.27 A
0.49 A
0.23 A
0.43 A
0.19 A
0.94 A
0.41 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.80
0.80
0.87
0.87
0.76
0.76
0.83
0.83
0.75
0.75
0.79
0.79
0.70
0.73
0.79
0.79
0.80
0.80
0.86
0.86
0.79
0.79
0.85
0.85
Ballast Efficacy Factor
0.80
0.82
1.00
1.01
0.80
0.82
1.05
1.06
0.87
0.88
1.08
1.10
0.91
0.95
1.22
1.22
1.03
1.04
1.30
1.32
1.44
1.44
1.85
1.85
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
99
97
99
97
99
98
99
97
99
97
99
97
99
96
99
95
99
97
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
8
15
10
18
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
4 or 3 – F32T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
74463
Pallet Pack
74464 (replaces 30271)
DIY Pack
74465 (replaces 97711)
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25 in (635 mm)
31 in (787 mm)
47 in (1194 mm)
31 in (787 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F25T8
F17T8
F40T8
Nom. Line Current
0.99 A
0.43 A
0.83 A
0.36 A
0.90 A
0.40 A
0.77 A
0.33 A
0.83 A
0.36 A
0.68 A
0.30 A
0.00 A
0.00 A
0.00 A
0.00 A
0.77 A
0.34 A
0.64 A
0.28 A
0.53 A
0.23 A
0.45 A
0.20 A
0.99 A
0.43 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.88
0.88
0.93
0.93
0.83
0.83
0.91
0.91
0.82
0.82
0.85
0.85
0.80
0.80
0.85
0.85
0.87
0.87
0.93
0.93
0.87
0.87
0.91
0.91
Ballast Efficacy Factor
0.78
0.80
1.00
1.01
0.81
0.81
1.05
1.06
0.88
0.89
1.10
1.11
0.91
0.92
1.16
1.16
0.99
1.01
1.28
1.29
1.45
1.44
1.80
1.78
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
98
99
98
99
98
99
98
99
98
99
98
99
97
99
98
99
98
99
97
99
97
99
98
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
15
10
16
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
0.0/-18
0.0/-18
T12 Magnetic
Safety and performance
System Watts
113
110
93
92
103
103
87
86
93
92
77
77
88
87
73
73
88
86
73
72
60
60
51
51
112
110
T12 Electronic
& High Output
F32T8/25W
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F32T8
# of Lamps
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
4
4
3
3
3
3
Programmed
Start Dimming
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
White
Red
Yellow
Blue
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
74463 – GE-432-MV-N (replaces 30193)
Ballasts
gelighting.com
RoHS Compliant
Sign
Compact
Fluorescent
10-49
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Multivolt 120V–277V
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps
30195 – GE-159-MV-N
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Red
White
Black
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
30195
Pallet Pack
30274
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
0.87 in (22 mm)
0.3 in (8 mm)
1.06 lbs
Side
18 ft
18 AWG
Length (± 1 in)
66 in (1676 mm)
25 in (635 mm)
25 in (635 mm)
58 in (1473 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WM
F96T8/WMP
# of Lamps
1
1
1
1
1
1
Line Volts
120
277
120
277
120
277
Safety and performance
System Watts
60
59
56
54
Nom. Line Current
0.55 A
0.22 A
0.51 A
0.22 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.89
0.89
0.85
0.85
Ballast Efficacy Factor
1.48
1.50
1.53
1.57
FCC – CLASS A Non-Consumer
74469 – GE-259-MV-N (replaces 30194)
2 or 1 – F96T8 120 to 277 “N” .87 BF Multivolt ProLine®
General characteristics
50 Hz/60 Hz
Order information
Pallet Pack
74470 (replaces 30272)
DIY Pack
74471 (replaces 97712)
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
50 / 10
50 / 10
50 / 10
50 / 10
RoHS Compliant
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
White
Red
Black
Electrical characteristics
10 Pack
74469
UL Listed
THD% (<=)
10
18
10
18
10
18
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Supply Current Frequency
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Multivolt 120V – 277V
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
UL Class P
Power Factor% (>=)
99
96
99
96
99
96
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
58.0 in (1473 mm)
25.0 in (635 mm)
66.0 in (1676 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WM
F96T8/WMP
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
Safety and performance
10-50
System Watts
113
110
72
72
104
101
67
66
Nom. Line Current
1.01 A
0.40 A
0.66 A
0.29 A
0.93 A
0.42 A
0.63 A
0.28 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.88
0.88
0.88
0.88
1.04
1.04
Ballast Efficacy Factor
0.78
0.80
1.22
1.23
1.00
1.03
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
98
99
97
99
98
99
97
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
0.0/-18
0.0/-18
0.0/-18
0.0/-18
60.0/16
60.0/16
60.0/16
60.0/16
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Multivolt High Output 120V–277V
T8 Instant Start Ballasts For 44 – 86W 4 ft – 8 ft HO Lamps
30176 – GE-286-HO-MV-N
ProLine® T8 Multivolt High Output 120V – 277V
2 or 1 – F96T8HO IS 120 to 277 “N” .87 BF
General characteristics
Dimensions
Electronic – Multivolt Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
30176
Pallet Pack
30187
DIY Pack
IP Pack
9.5 in (241 mm)
2.4 in (61 mm)
1.6 in (40 mm)
8.9 in (226 mm)
1.7 in (43 mm)
0.3 in (8 mm)
2.04 lbs
Side
18 ft
18 AWG
Length (± 1 in)
58 in (1473 mm)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
F96T8/WM
F96T8/WMP
F96T8/HO
F60T8HO
F58T8
F40T8
Safety and performance
Nom. Line Current
1.29 A
0.52 A
0.79 A
0.33 A
1.23 A
0.51 A
0.77 A
0.33 A
1.11 A
0.47 A
0.69 A
0.30 A
1.30 A
0.56 A
0.82 A
0.36 A
1.02 A
0.43 A
0.64 A
0.28 A
0.84 A
0.35 A
0.53 A
0.24 A
0.72 A
0.30 A
0.45 A
0.20 A
0.70 A
0.30 A
0.45 A
0.20 A
0.87 A
0.37 A
0.55 A
0.25 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
1.17
1.17
1.36
1.36
1.15
1.15
1.35
1.35
1.37
1.37
1.63
1.63
0.82
0.82
0.93
0.93
0.82
0.82
0.95
0.95
0.81
0.81
0.95
0.95
0.80
0.80
0.93
0.93
0.82
0.82
0.95
0.95
1.20
1.20
1.39
1.37
Ballast Efficacy Factor
0.82
0.84
1.56
1.58
0.85
0.86
1.57
1.57
1.10
1.11
2.09
2.12
0.56
0.57
1.01
1.03
0.71
0.72
1.30
1.32
0.85
0.88
1.58
1.53
1.03
1.03
1.90
1.86
1.05
1.06
1.86
1.86
1.22
1.24
2.24
2.21
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
97
99
97
99
98
99
97
99
98
99
96
99
97
98
96
99
97
99
95
99
97
99
94
99
96
99
93
99
96
99
93
99
97
99
94
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
0.0/-18
T12 Magnetic
F48T8HO
System Watts
142
139
87
86
136
134
86
86
125
123
78
77
146
143
92
90
115
114
73
72
95
92
60
62
78
78
49
50
78
77
51
51
98
97
62
62
T12 Electronic
& High Output
F72T8HO
Line Volts
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
120
277
T5 Electronic
Programmed Start
F96T8
# of Lamps
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
Programmed
Start Dimming
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing ST – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Blue
White
Red
Black
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Multi-voltage technology handles voltage from 120 to 277V
• Lightweight, low-profile housing
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
RoHS Compliant
Sign
Compact
Fluorescent
10-51
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Instant Start 120V and 277V High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
23680 – GE-132-120-N
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
1 – F32T8 120V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23680
Pallet Pack
24161
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F25T12
F28T8
F25T8
F17T8
FE15T8
# of Lamps
1
1
1
1
1
1
1
Line Volts
120
120
120
120
120
120
120
System Watts
30
28
25
25
24
18
15
Safety and performance
Nom. Line Current
0.26 A
0.24 A
0.22 A
0.22 A
0.21 A
0.16 A
0.13 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.86
0.87
0.84
0.87
0.91
0.91
Ballast Efficacy Factor
2.90
3.07
3.48
3.36
3.62
5.05
6.06
FCC – CLASS A Non-Consumer
23681 – GE-132-277-N
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
0 / -18
60 / 16
0 / -18
60 / 16
0 / -18
0 / -18
0 / -18
RoHS Compliant
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
1 – F32T8 277V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23681
UL Class P
Power Factor% (>=)
99
99
99
99
99
99
99
Pallet Pack
24162
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F25T12
F25T8
F17T8
FE15T8
# of Lamps
1
1
1
1
1
1
1
Line Volts
277
277
277
277
277
277
277
Safety and performance
10-52
System Watts
30
28
26
25
25
18
15
Nom. Line Current
0.12 A
0.11 A
0.97 A
0.10 A
0.10 A
0.07 A
0.06 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.86
0.84
0.87
0.87
0.91
0.91
Ballast Efficacy Factor
2.90
3.07
3.23
3.48
3.48
5.05
6.06
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
99
97
97
97
96
94
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
11
11
14
16
Min. Starting Temp (°F/°C)
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Instant Start 120V and 277V High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
23671 – GE-232-120-N
ProLine® T8 Instant Start High Performance
2 or 1 – F32T8 120V “N” .87 BF ProLine®
General characteristics
Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Pallet Pack
24163
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F25T8
F40T8
F17T8
FE15T8
Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
System Watts
57
36
53
33
48
30
46
30
45
28
43
31
20
25
17
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
Ballast Efficacy Factor
1.52
2.61
1.62
2.84
1.75
3.03
1.89
3.13
1.93
3.46
0.91
0.97
0.91
0.98
2.93
4.85
3.64
5.76
UL Type HL
FCC – CLASS A Non-Consumer
23672 – GE-232-277-N
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
13
11
15
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
2 or 1 – F32T8 277V “N” .87 BF ProLine®
Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Pallet Pack
24164
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)
Sign
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
T12 Magnetic
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
10 Pack
23672
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
99
98
98
98
T12 Electronic
& High Output
Safety and performance
Nom. Line Current
0.49 A
0.31 A
0.45 A
0.29 A
0.41 A
0.26 A
0.40 A
0.26 A
0.38 A
0.25 A
0.37 A
0.27 A
0.18 A
0.22 A
0.15 A
T5 Electronic
Programmed Start
F28T8
F25T12
# of Lamps
2
1
2
1
2
1
2
1
2
1
1
2
1
2
1
Programmed
Start Dimming
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
10 Pack
23671
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
Specifications by lamp and wattage
Lamp
F32T8/WM
F28T8
F25T12
F25T8
F40T8
FE15T8
Line Volts
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277
Safety and performance
See page E-1 for warranty information.
System Watts
57
37
53
34
48
31
47
31
45
29
44
32
22
26
18
Nom. Line Current
0.22 A
0.14 A
0.20 A
0.13 A
0.18 A
0.12 A
0.18 A
0.12 A
0.17 A
0.11 A
0.16 A
0.12 A
0.08 A
0.10 A
0.07 A
UL Type 1 Outdoor
NRCan
System Ballast Factor
0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
Ballast Efficacy Factor
1.52
2.54
1.62
2.76
1.75
2.93
1.85
3.03
1.93
3.34
0.91
0.97
0.91
0.98
2.84
4.40
3.50
5.44
UL Type HL
FCC – CLASS A Non-Consumer
Power Factor% (>=)
99
99
99
99
99
97
98
97
98
97
99
98
96
97
95
UL Class P
cUL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
UL Listed
THD% (<=)
10
10
10
10
10
10
10
13
10
13
10
12
16
14
17
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
10-53
HID Electronic &
Electromagnetic
F17T8
# of Lamps
2
1
2
1
2
1
2
1
2
1
1
2
1
2
1
Compact
Fluorescent
F32T8
ProLine® T8 Instant Start 120V and 277V High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
23673 – GE-332-120-N
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
3 or 2 – F32T8 120V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23673
Pallet Pack
24165
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
45 in (1143 mm)
25 in (635 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F40T8
F28T8
F25T12
F25T8
F17T8
# of Lamps
3
2
3
2
2
3
2
3
2
3
2
3
2
2
Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120
System Watts
85
65
79
60
78
72
54
69
54
67
51
47
30
30
Safety and performance
Nom. Line Current
0.73 A
0.56 A
0.68 A
0.51 A
0.67 A
0.62 A
0.47 A
0.60 A
0.46 A
0.58 A
0.44 A
0.41 A
0.31 A
0.26 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.94
0.86
0.94
Ballast Efficacy Factor
1.02
1.44
1.08
1.56
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.98
1.16
1.68
1.26
1.74
1.29
1.90
1.93
3.23
3.26
FCC – CLASS A Non-Consumer
23674 – GE-332-277-N
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
12
13
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
3 or 2 – F32T8 277V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23674
UL Class P
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
99
99
98
Pallet Pack
24166
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
24 in (610 mm)
32 in (813 mm)
24 in (610 mm)
32 in (813 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F40T8
F28T8
F25T12
F25T8
F17T8
FE15T8
# of Lamps
3
2
3
2
2
3
2
3
2
3
2
3
2
3
2
Line Volts
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277
Safety and performance
10-54
System Watts
84
64
78
59
77
70
53
68
53
65
50
46
36
36
28
Nom. Line Current
0.31 A
0.24 A
0.29 A
0.22 A
0.29 A
0.26 A
0.20 A
0.25 A
0.20 A
0.24 A
0.19 A
0.17 A
0.13 A
0.14 A
0.11 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.94
0.86
0.94
Ballast Efficacy Factor
1.03
1.46
1.10
1.59
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98
1.20
1.71
1.27
1.77
1.33
1.94
1.97
2.69
2.52
3.50
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
99
99
99
99
99
98
99
98
99
98
98
97
98
97
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
11
10
12
12
15
15
16
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
0 / -18
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 Instant Start 120V and 277V High Performance
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft), F40 (5 ft) Lamps
23675 – GE-432-120-N
ProLine® T8 Instant Start High Performance
4 or 3 – F32T8 120V “N” .87 BF ProLine®
General characteristics
Dimensions
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
Pallet Pack
24167
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
47 in (1194 mm)
31 in (787 mm)
31 in (787 mm)
Specifications by lamp and wattage
Lamp
F32T8
F40T8
F28T8
F25T12
F25T8
F17T8
FE15T8
Line Volts
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
Nom. Line Current
0.97 A
0.80 A
0.97 A
0.90 A
0.74 A
0.81 A
0.66 A
0.78 A
0.65 A
0.74 A
0.62 A
0.52 A
0.43 A
0.42 A
0.35 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
0.94
Ballast Efficacy Factor
0.76
1.01
Power Factor% (>=)
0.87
0.94
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98
0.81
1.09
0.87
1.18
0.95
1.25
1.00
1.34
1.51
1.94
1.89
2.45
0.86
0.94
0.84
0.91
0.87
0.94
0.87
0.97
0.91
0.97
0.91
0.98
FCC – CLASS A Non-Consumer
UL Class P
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
10
10
10
10
10
10
11
12
14
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
T12 Electronic
& High Output
Safety and performance
System Watts
113
93
113
105
86
96
77
91
75
87
72
60
50
48
40
T5 Electronic
Programmed Start
F32T8/WM
# of Lamps
4
3
3
4
3
4
3
4
3
4
3
4
3
4
3
Programmed
Start Dimming
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
White and Black
Yellow
Red
Blue
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
10 Pack
23675
T8 Instant Start
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
Ballasts
gelighting.com
T12 Magnetic
Sign
Compact
Fluorescent
10-55
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
ProLine® T8 Instant Start 120V and 277V High Performance
T8 Instant Start Ballasts For 46 – 59W 4 ft – 8 ft Slimline Lamps
23677 – GE-259-120-N
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
2 or 1 – F96T8 120V Normal Light .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23677
Pallet Pack
24169
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
58 in (1473 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WM
F96T8/WMP
# of Lamps
2
1
2
1
1
2
Line Volts
120
120
120
120
120
120
System Watts
112
71
104
65
Safety and performance
Nom. Line Current
0.96 A
0.61 A
0.89 A
0.56 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
1.04
0.87
1.04
Ballast Efficacy Factor
0.77
1.46
0.83
1.60
FCC – CLASS A Non-Consumer
23678 – GE-259-277-N
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
10
10
10
10
10
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
• High-performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Lightweight, low-profile housing
• < 10% THD, > 99% power factor
• Parallel lamp operation means system maintenance is easier to manage
ProLine® T8 Instant Start High Performance
2 or 1 – F96T8 277V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Auto-restart, Thermally protected
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Red
White
Blue
Electrical characteristics
Supply Current Frequency
50 Hz/60 Hz
Order information
10 Pack
23678
UL Class P
Power Factor% (>=)
99
99
99
99
99
99
Pallet Pack
24170
DIY Pack
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.40 lbs
Side
18 ft
18 AWG
Length (± 1 in)
25 in (635 mm)
66 in (1676 mm)
25 in (635 mm)
58 in (1473 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WM
F96T8/WMP
# of Lamps
2
1
2
1
1
2
Line Volts
277
277
277
277
277
277
Safety and performance
10-56
System Watts
110
71
102
66
Nom. Line Current
0.41 A
0.27 A
0.38 A
0.25 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.87
1.04
0.87
1.04
Ballast Efficacy Factor
0.79
1.46
0.85
1.57
FCC – CLASS A Non-Consumer
UL Class P
Power Factor% (>=)
99
99
99
98
98
99
cUL Listed
UL Listed
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
THD% (<=)
10
13
10
13
13
10
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
0 / -18
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 347V Instant Start High Performance
T8 Instant Start Ballasts
ProLine® T8 347V Instant Start High Performance
1 – F32T8 347V “N” .87 BF ProLine®
General characteristics
• High performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Light-weight, Slim Profile Mini Can Housing
• Parallel lamp operation means system maintenance is easier to manage
Dimensions
Electronic - Standard Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
74102
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
# of Lamps
1
1
1
1
1
1
1
1
1
Line Volts
347
347
347
347
347
347
347
347
347
Safety and performance
System Watts
30
28
26
24
23
20
17
14
24
Type 1 Outdoor
Nom. Line Current
0.09 A
0.08 A
0.08 A
0.07 A
0.06 A
0.05 A
0.07 A
Type HL
System Ballast Factor
0.87
0.86
0.84
0.84
0.88
0.88
0.81
0.75
0.88
Meets ICES-005 for EMI and RFI
ANSI - C82.11 - Cons 2002,
ProLine® T8 347V Instant Start High Performance
2 or 1 – F32T8 347V “N” .87 BF ProLine®
General characteristics
Power Factor% (>=)
97
96
96
96
95
95
87
81
95
ANSI - C62.41 - 1991
Crest Factor (<=)
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
THD% (<=)
4
6
6
6
7
7
17
20
7
Min. Starting Temp (°F/°C)
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
T12 Electronic
& High Output
74103 – GE232-N-347
• High performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Light-weight, Slim Profile Mini Can Housing
• Parallel lamp operation means system maintenance is easier to manage
Dimensions
Electronic - Standard Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
74104
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Sign
Order information
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T12 Magnetic
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74103
Ballast Efficacy Factor
2.90
3.07
3.23
3.50
3.83
4.40
4.76
5.36
3.67
T5 Electronic
Programmed Start
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
FE15T8
F25T12
Programmed
Start Dimming
Order information
Wiring diagram – LFL 1A – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74101
T8 Instant Start
74101 – GE132-N-347
Ballasts
gelighting.com
Specifications
Lamp
F32T8
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
F25T12
Safety and performance
System Watts
55
34
52
32
48
30
44
41
26
35
29
19
24
24
16
44
28
Type 1 Outdoor
See page E-1 for warranty information.
Nom. Line Current
0.16 A
0.11 A
0.15 A
0.09 A
0.14 A
0.09 A
Type HL
0.12 A
0.08 A
0.09 A
0.07 A
0.08 A
0.06 A
0.13 A
0.08 A
System Ballast Factor
0.87
1.03
0.85
1.01
0.84
1.00
0.84
0.88
1.04
0.88
0.83
0.99
0.83
0.76
0.89
0.88
1.07
Meets ICES-005 for EMI and RFI
Ballast Efficacy Factor
1.58
3.03
1.63
3.16
1.75
3.33
1.91
2.15
4.00
2.51
2.86
5.21
3.46
3.17
5.56
2.00
3.82
ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
97
99
97
99
96
99
98
95
98
96
84
96
90
78
98
96
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.4
1.6
1.4
1.5
1.4
1.5
1.6
1.5
1.6
1.6
1.5
1.6
1.6
1.5
1.6
1.4
THD% (<=)
5
8
5
8
5
9
5
6
11
6
10
50
10
30
66
6
10
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
10-57
HID Electronic &
Electromagnetic
FE15T8
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Compact
Fluorescent
F32T8/WM
# of Lamps
2
1
2
1
2
1
2
2
1
2
2
1
2
2
1
2
1
ProLine® T8 347V Instant Start High Performance
T8 Instant Start Ballasts
74105 – GE332-N-347
ProLine® T8 347V Instant Start High Performance
3 or 2 – F32T8 347V “N” .87 BF ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Electronic - Standard Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74105
• High performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Light-weight, Slim Profile Mini Can Housing
• Parallel lamp operation means system maintenance is easier to manage
Pallet Pack
74106
DIY Pack
IP Pack
Wiring diagram – LFL 1C – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
45.0 in (1143 mm)
25.0 in (635 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F25T12
# of Lamps
3
2
3
2
3
2
3
3
2
3
3
2
3
3
2
3
2
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
System Watts
82
60
78
57
73
53
66
62
48
53
44
34
37
32
25
65
51
Type 1 Outdoor
Nom. Line Current
0.23 A
0.17 A
0.22 A
0.17 A
0.20 A
0.15 A
0.18 A
0.14 A
0.13 A
0.11 A
0.10 A
0.08 A
0.19 A
0.15 A
Type HL
System Ballast Factor
0.87
0.97
0.85
0.98
0.83
0.94
0.83
0.88
0.98
0.88
0.83
0.93
0.83
0.76
0.85
0.88
1.00
Ballast Efficacy Factor
1.06
1.62
1.09
1.72
1.14
1.77
1.26
1.42
2.04
1.66
1.89
2.74
2.24
2.38
3.40
1.35
1.96
Meets ICES-005 for EMI and RFI ANSI - C82.11 - Cons 2002,
74107 – GE432-N-347
ProLine® T8 347V Instant Start High Performance
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
98
91
98
96
91
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.6
1.6
1.5
1.6
1.5
1.6
1.6
1.5
1.6
1.7
1.6
1.7
1.6
1.6
1.6
1.5
THD% (<=)
5
5
5
5
4
6
4
5
6
5
8
34
8
14
41
5
6
Min. Starting Temp (°F/°C)
-22.0/-30
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
• High performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Light-weight, Slim Profile Mini Can Housing
• Parallel lamp operation means system maintenance is easier to manage
4 or 3 – F32T8 347V “N” .87 BF ProLine®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
Electronic - Standard Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Order information
10 Pack
74107
Pallet Pack
74108
DIY Pack
IP Pack
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
Yellow
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
25.0 in (635 mm)
31.0 in (787 mm)
31.0 in (787 mm)
25.0 in (635 mm)
47.0 in (1194 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F32T8/25W
F25T8
F25T8/WM
F17T8
F17T8/WM
FE15T8
F25T12
# of Lamps
4
3
4
3
4
3
4
4
3
4
4
3
4
4
3
4
3
Line Volts
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
347
Safety and performance
10-58
System Watts
109
87
103
83
96
76
87
83
68
71
52
48
44
47
38
87
72
Type 1 Outdoor
Nom. Line Current
0.30 A
0.25 A
0.29 A
0.24 A
0.27 A
0.22 A
Type HL
0.24 A
0.20 A
0.17 A
0.14 A
0.14 A
0.12 A
0.25 A
0.21 A
System Ballast Factor
0.88
0.95
0.86
0.94
0.84
0.92
0.84
0.88
0.96
0.88
0.84
0.91
0.84
0.76
0.82
0.89
0.97
Meets ICES-005 for EMI and RFI
Ballast Efficacy Factor
0.81
1.09
0.83
1.13
0.88
1.21
0.97
1.06
1.41
1.24
1.62
1.90
1.91
1.62
2.16
1.02
1.35
ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
99
99
99
99
99
99
99
99
99
99
98
99
98
91
99
99
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.5
1.6
1.5
1.6
1.5
1.6
1.6
1.5
1.6
1.6
1.5
1.6
1.5
1.5
1.6
1.5
THD% (<=)
5
6
5
6
5
6
5
6
8
6
10
3
10
12
36
6
7
Min. Starting Temp (°F/°C)
60.0/16
-22.0/-30
60.0/16
60.0/16
60.0/16
60.0/16
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
60.0/16
-22.0/-30
-22.0/-30
-22.0/-30
-22.0/-30
RoHS Compliant
See page E-1 for warranty information.
ProLine® T8 347V Instant Start High Performance
T8 Instant Start Ballasts
ProLine® T8 347V Instant Start High Performance
2 or 1 – F96T8 347V “N” .87 BF ProLine®
General characteristics
Dimensions
Electronic - High Efficiency Multivolt Instant Start
Instant start
Parallel
10 %
70 °C (158 °F)
Normal
Active
A (20-24 decibels)
Metal Can
Anti-striation control, Auto-restart, Inherent thermal protection
Electrical characteristics
Supply Current Frequency (MIN)
60 Hz
Pallet Pack
74100
DIY Pack
IP Pack
9.5 in (241 mm)
1.3 in (33 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.04 lbs
Side
18 ft
18 AWG
Length (± 1 in.)
22.0 in (559 mm)
46.0 in (1168 mm)
78.0 in (1981 mm)
22.0 in (559 mm)
Specifications by lamp and wattage
Lamp
F96T8
F96T8/WMP
Line Volts
347
347
347
347
347
347
Safety and performance
System Watts
108
67
102
64
95
60
Type 1 Outdoor
Nom. Line Current
0.31 A
0.20 A
0.29 A
0.19 A
0.27 A
0.17 A
Type HL
System Ballast Factor
0.88
1.06
0.88
1.05
1.05
1.26
Meets ICES-005 for EMI and RFI
Ballast Efficacy Factor
0.81
1.58
0.86
1.64
1.11
2.10
ANSI - C82.11 - Cons 2002,
Power Factor% (>=)
99
98
99
98
99
98
ANSI - C62.41 - 1991
Crest Factor (<=)
1.6
1.6
1.5
1.5
1.5
1.5
THD% (<=)
5
10
5
10
6
10
Min. Starting Temp (°F/°C)
0.0/-18
0.0/-18
60.0/16
60.0/16
60.0/16
60.0/16
RoHS Compliant
T5 Electronic
Programmed Start
F96T8/WM
# of Lamps
2
1
2
1
2
1
Programmed
Start Dimming
Order information
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp
Remote Mounting Wire Gauge
Lead lengths
Black
Blue
Red
White
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Enclosure Type
Additional Info
10 Pack
74099
• High performance electronic ballast for all general fluorescent applications
• Instant start electronic ballast for long lamp starting cycles and low initial cost
• Light-weight, Slim Profile Mini Can Housing
• Parallel lamp operation means system maintenance is easier to manage
T8 Instant Start
74099 – GE259-N-347
Ballasts
gelighting.com
T12 Electronic
& High Output
T12 Magnetic
Sign
Compact
Fluorescent
10-59
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Residential Grade ProLine® T8 120V
T8 Instant Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
97782 – GE232-120-RES
• Residential grade -instant start
• EMI/RFI meets FCC Class B Consumer Limits
• Meets ballast requirements of Energy Star Residential Lighting Fixture program
Residential Grade ProLine® T8 120V
2 or 1 – F32T8 120V “N” .87 BF Residential ProLine®
Dimensions
General characteristics
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Active
A (20-24 decibels)
Thermally protected
Wiring diagram – LFL 1B – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
Blue
White and Black
Black
Electrical characteristics
Supply Current Frequency
Supply Current Frequency (MIN)
60 Hz
50 Hz
Order information
10 Pack
97782
Pallet Pack
DIY Pack
71037
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
45 in (1143 mm)
31 in (787 mm)
25 in (635 mm)
25 in (635 mm)
Specifications by lamp and wattage
Lamp
# of Lamps
Line Volts
2
120
1
120
2
120
F32T8/WM
1
120
2
120
F28T8
1
120
2
120
F25T8
1
120
2
120
F17T8
1
120
Other compatible lamps: F32T8/25W
F32T8
Safety and performance
System Watts
53
32
51
32
46
29
43
28
31
20
Nom. Line Current
0.81 A
0.55 A
0.79 A
0.54 A
0.72 A
0.50 A
0.69 A
0.48 A
0.52 A
0.37 A
RoHS Compliant
UL Type 1 Outdoor
System Ballast Factor
0.83
0.99
0.82
0.99
0.81
0.97
0.88
1.04
0.88
1.03
UL Type HL
Ballast Efficacy Factor
1.56
3.09
1.60
3.09
1.76
3.34
2.04
3.71
2.83
5.15
ANSI – C62.41
97783 – GE432-120-RES
UL Class P
Power Factor% (>=)
5
48
5
48
5
48
5
48
49
45
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
FCC Part 18 Class B at 120 Volts
THD% (<=)
145
170
146
170
152
177
155
178
172
195
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
cUL Listed
• Residential grade -instant start
• EMI/RFI meets FCC Class B Consumer Limits
• Meets ballast requirements of Energy Star Residential Lighting Fixture program
Residential Grade ProLine® T8 120V
4 or 3 – F32T8 120V “N” .87 BF Residential ProLine®
General characteristics
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
Electronic – Standard Instant Start
Instant start
Parallel
10%
70°C (158°F)
Normal
Wiring diagram – LFL 1D – see example on Page 10-62
Case dimensions – Ref Drawing -A – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Red
Blue
White and Black
Yellow
A (20-24 decibels)
Thermally protected
Electrical characteristics
Supply Current Frequency
Supply Current Frequency (MIN)
60 Hz
50 Hz
Order information
10 Pack
97783
Pallet Pack
DIY Pack
71038
IP Pack
9.5 in (241 mm)
1.7 in (43 mm)
1.18 in (30 mm)
8.9 in (226 mm)
1.18 in (30 mm)
0.3 in (8 mm)
1.65 lbs
Side
18 ft
18 AWG
Length (± 1 in)
31 in (787 mm)
31 in (787 mm)
25 in (635 mm)
47 in (1194 mm)
Specifications by lamp and wattage
Lamp
F32T8
F32T8/WM
F28T8
F25T8
F17T8
# of Lamps
4
3
4
3
4
3
4
3
4
3
Line Volts
120
120
120
120
120
120
120
120
120
120
Safety and performance
10-60
System Watts
105
86
98
81
90
75
83
68
58
48
Nom. Line Current
1.62 A
1.38 A
1.50 A
1.29 A
1.42 A
1.23 A
1.31 A
1.13 A
0.98 A
0.84 A
UL Type 1 Outdoor
RoHS Compliant
System Ballast Factor
0.83
0.88
0.81
0.88
0.79
0.87
0.87
0.94
0.86
0.93
UL Type HL
Ballast Efficacy Factor
0.79
1.02
0.82
1.08
0.87
1.16
1.04
1.38
1.48
1.93
ANSI – C62.41
Power Factor% (>=)
5
5
5
5
5
5
5
5
48
44
FCC Part 18 Class B at 120 Volts
Crest Factor (<=)
1.7
1.7
1.7
1.7
1.7
0.19
1.7
1.7
1.7
1.7
UL Class P
cUL Listed
THD% (<=)
147
157
150
159
155
165
158
167
175
185
Min. Starting Temp (°F/°C)
0 / -18
0 / -18
60 / 16
60 / 16
60 / 16
60 / 16
0 / -18
0 / -18
0 / -18
0 / -18
UL Listed
See page E-1 for warranty information.
Electromagnetic T8 120V and 277V Ballasts
T8 Rapid Start Ballasts For F17 (2 ft), F25 (3 ft), F32 (4 ft) Lamps
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Great for areas requiring no EMI/RFI noise
Electromagnetic T8 Ballasts
2 – F32T8, RS, 120V, Magnetic Ballast (M232SR120C)
Dimensions
General characteristics
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
60 Hz
Order information
10 Pack
87125
Pallet Pack
DIY Pack
IP Pack
87125
9.5 in (241 mm)
2.4 in (61 mm)
1.6 in (40 mm)
8.9 in (226 mm)
1.7 in (43 mm)
0.3 in (8 mm)
2.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
26 in (660 mm)
20 in (508 mm)
36 in (914 mm)
Specifications by lamp and wattage
Lamp
F32T8
# of Lamps
2
Line Volts
120
System Watts
32
Safety and performance
Nom. Line Current
0.60 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.94
CSA
Ballast Efficacy Factor
2.93
UL Class P
Power Factor% (>=)
98
Crest Factor (<=)
1.7
THD% (<=)
18
Min. Starting Temp (°F/°C)
50 / 10
Programmed
Start Dimming
Wiring diagram – LFL PS2 – see example on Page 10-62
Case dimensions – Ref Drawing ST – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow
T8 Programmed
Start
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T8 Instant Start
87125 – GEM232T8RS120
Ballasts
gelighting.com
UL Listed
T5 Electronic
Programmed Start
• Magnetic ballast construction for all general fluorescent lighting
• Extends lamp life in frequently switched applications
• Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red)
• Great for areas requiring no EMI/RFI noise
Electromagnetic T8 Ballasts
2 – F32T8, RS, 277V, Magnetic Ballast (M232SR277C)
General characteristics
Magnetic – Rapid Start
Rapid start
Series
5%
105°F (41°C)
90°C (194°F)
Normal
A (20-24 decibels)
Auto-restart, Thermally protected
Electrical characteristics
Supply Current Frequency
60 Hz
Pallet Pack
DIY Pack
IP Pack
87130
9.5 in (241 mm)
2.4 in (61 mm)
1.6 in (40 mm)
8.9 in (226 mm)
1.7 in (43 mm)
0.3 in (8 mm)
2.60 lbs
Side
10 ft
18 AWG
Length (± 1 in)
26 in (660 mm)
20 in (508 mm)
36 in (914 mm)
Sign
Order information
10 Pack
87130
Wiring diagram – LFL PS2 – see example on Page 10-62
Case dimensions – Ref Drawing ST – see Page 10-65
Length (L)
Width (W)
Height (H)
Mounting dimensions
Mount Length (M)
Mount Width (X or F)
Mount Slots (MS)
Weight
Exit Type
Remote Mounting Distance to Lamp (F32T8)
Remote Mounting Wire Gauge
Lead lengths
Blue and Red
White and Black
Yellow
T12 Magnetic
Dimensions
Ballast Type
Starting Method
Lamp Wiring
Line Voltage Regulation (+/-)
Ambient Temperature (MAX)
Case Temperature (MAX)
Ballast Factor
Power Factor Correction
Sound Rating
Additional Info
T12 Electronic
& High Output
87130 – GEM232T8RS277
Specifications by lamp and wattage
# of Lamps
2
2
2
Line Volts
277
277
277
Safety and performance
Nom. Line Current
0.28 A
0.22 A
0.18 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor
0.98
1.00
1.09
UL Class P
Ballast Efficacy Factor
1.27
1.66
2.31
Power Factor% (>=)
98
98
96
Crest Factor (<=)
1.7
1.7
1.7
THD% (<=)
20
20
25
Min. Starting Temp (°F/°C)
50 / 10
50 / 10
50 / 10
UL Listed
10-61
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
System Watts
77
60
47
Compact
Fluorescent
Lamp
F32T8
F25T8
F17T8
Wiring Diagrams
T8 Instant Start Ballasts
LFL 1A
LFL 1B
LFL 1C
LFL 1D
LFL PS2
Line
Black
White
Green
Blue
BALLAST
Red
Yellow
Connect Green wire
to case and fixture
LAMP
LAMP
10-62
dr_LFL_PS 2
See page E-1 for warranty information.
Wiring Diagrams
T8 Instant Start Ballasts
BALLAST
Control
Gray
Violet
BALLAST
T8 Programmed
Start
Switching
Gray
LFL -6H V60
T8 Instant Start
LFL -6H S60
Ballasts
gelighting.com
Programmed
Start Dimming
Neutral
White
LFL -4H V60
BALLAST
BALLAST
T12 Electronic
& High Output
(–) Gray
Control
(+) Violet
T5 Electronic
Programmed Start
LFL -4H S60
T12 Magnetic
Sign
Compact
Fluorescent
10-63
HID Electronic &
Electromagnetic
See page E-1 for warranty information.
Wiring Diagrams
T8 Instant Start Ballasts
LFL -3H S60
LFL -3H V60
BALLAST
Neutral
LFL -2H S60
10-64
BALLAST
LFL -2H V60
BALLAST
Neutral
(-) Gray
Control
(+) Violet
(–) Gray
Control
(+) Violet
BALLAST
See page E-1 for warranty information.
Case Dimensions
T8 Instant Start Ballasts
T8 Programmed
Start
Programmed
Start Dimming
T5 Electronic
Programmed Start
T12 Electronic
& High Output
T12 Magnetic
Sign
Compact
Fluorescent
ST
LG
HID Electronic &
Electromagnetic
10-65
See page E-1 for warranty information.
T8 Instant Start
-A
Ballasts
gelighting.com
T8 Instant Start Ballasts
Notes
10-66
See page E-1 for warranty information.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project