CX-Programmer Ver.8 - Mouser Electronics

CX-Programmer Ver.8 - Mouser Electronics
FA Integrated Tool Package CX-One
CX-Programmer Ver.8
CSM_CX-Programmer_Ver8_DS_E_1_1
Improve Productivity for SYSMAC
PLCs from Ladder Program
Development and Unit Setup to
Debugging and Maintenance
• Application software to create and debug programs for
SYSMAC CS/CJ/CP/NSJ-series, C-series, and
CVM1/C-series CPU Units.
Features
•
•
•
•
•
•
•
Easily Achieve Position Control with Wading Through User Manuals.
Complete Support for Synchronous Operation between Units.
Easier Connection to PLCs.
Batch Backup/Restore with a Computer.
Comprehensive Programming Environment.
High Program Readability.
Time Required for Onsite Startup and Debugging Has Been Significantly Reduced.
1
CX-Programmer Ver.8
Ordering Information
• International Standards
• The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division
2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Support Software
Specifications
Product name
FA Integrated Tool
Package
CX-One [email protected]
Number of
licenses
The CX-One is a package that integrates the Support Software
for OMRON PLCs and components. CX-One runs on the
following OS.
Windows 2000 (Service Pack 3 or higher), XP, or Vista
CX-One [email protected] includes CX-Programmer [email protected]
For details, refer to the CX-One catalog (Cat. No. R134).
Model
Media
CD
Standards
CXONE-AL01C-V3
1 license *1
−
DVD
*2
CXONE-AL01D-V3
CX-Programmer can still be ordered individually in the following model numbers.
CX-Programmer
[email protected]
PLC programming software
OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista
1 licenses
CD
WS02-CXPC1-V8
−
3 licenses
CD
WS02-CXPC1-V8L03
−
10 licenses
CD
WS02-CXPC1-V8L10
−
*1. Multi licenses are available for the CX-One (3, 10, 30, or 50 licenses).
*2. When purchasing the DVD format, verify the computer model and DVD drive specifications before purchasing.
Support Software (Micro PLC Edition)
Specifications
Product name
Micro PLC Edition
CX-Programmer
[email protected]
PLC Support Software
OS: Windows 2000 (Service Pack 3 or higher), XP, or Vista
Applicable models: CP1L, CP1H, [email protected]@, SRM1
Number of
licenses
Media
1 licence
CD
Applicable
computers
Cable
length
Model
Standards
−
WS02-CXPC2-V8
Connecting Cables for CX-Programmer
Product name
Model
Standards
0.1m
CS1W-CN118
CE
2m
CS1W-CN226
CE
6m
CS1W-CN626
CE
3.3m
CQM1-CIF02
U, C, N, L,
CE
2m
XW2Z-200P-V
−
5m
XW2Z-500P-V
−
2m
XW2Z-200S-CV
2m
XW2Z-200S-V
5m
XW2Z-500S-CV
−
5m
XW2Z-500S-V
−
0.5m
CS1W-CIF31
Programming Device Connecting Cables for
Peripheral Port
SYSMAC Host Link Cables (RS-232C cables
that are compatible with Programmable
Controllers)
IBM PC/AT or
compatible
computers, D-Sub 9pin
−
Programming Device Connecting Cables for
RS-232C Port
USB-Serial Conversion Cable and PC driver
(on a CD-ROM disk)
Complies with USB Specification 1.1.
IBM PC/AT or
compatible computer
(USB port)
N
2
CX-Programmer Ver.8
Product name
Applicable
computers
Cable
length
Model
Standards
Programming Console Connecting Cable
−
0.05m
CS1W-CN114
CE
Connecting Cable for peripheral and
RS-232C port
−
0.1m
CPM2C-CN111
CE
Peripheral interface Unit
−
3.3m
C200H-IP007
−
Connecting Cable for peripheral port
−
6m
CV500-CIF01
−
RS-232C Adapter
−
−
CPM1-CIF01
U, C, N, L,
CE
Peripheral/RS-232C Adapter Unit
−
−
CPM2C-CIF01-V1
U, C, CE
RS-422/RS-232C Adapter Unit
−
−
CPM2C-CIF11
U, C, CE
Simple Communications Unit
−|
−
CPM2C-CIF21
U, C, CE
Note: For information on confirmations of the CX-Programmer, Connecting Cables, and PLCs, refer to Applicable Peripheral Devices in this
datasheet.
Product Configuration
Setup disk : (CD) CD 1 piece in the case
Guidance : A4 size, English/Japanese
User license agreement/User registration card, English/Japanese
3
CX-Programmer Ver.8
Main Functions
Category
Function
Create Ladder program on Ladder View
Create Function Block Call on Ladder View
Ladder
Create Rung Comment on Ladder View
Create Symbol Comments on Ladder View
Create Attached Comment on Ladder View
Create Ladder program on Mnemonic View
Structured Text (ST)
Create Program in Structured Text language
Create Program in SFC
SFC
Create SFC Action program in Ladder or Structured Text language
Create SFC Transition program in Ladder or Structured Text language
Create Function Block Body in Ladder or Structured Text language
Function Block (FB)
Nesting Function Blocks (Up to 8 nesting levels)
Nesting Tree View (FB Instance Viewer)
Convert Ladder program to Function Block
Cross Reference Report
Cross Reference Pop-up
Programming
Program check
Symbol programming
Symbol check
Delete Unused Symbols
Address automatic allocation
CX-Programmer configuration function (Option)
Keyboard Mapping function
Common
Printing function
Find/Replace
Jump (Set Rung No./Program address/Set Rung with Commented Rung)
Expansion advanced instructions (C series)
UM area allocation (Set expansion fixed DM) (C200HS/E/G/X, CPM1/CPM1A, [email protected])
Rung wrap function of Ladder (Online)
Edit IO comments function
Section/Rung manage
ROM Writer function
Start The CX-Integrator (CS/CJ series)
Import old support software data (LSS *1, SSS *2, CVSS *3, CPT *4, SYSWIN data)
Import/Export reusable Symbol and Ladder Rung data file
C500/C120/C**P backup
Reuse of program
PLC Backup Tool Operation (Backup/Compare/Restore)
Memory Cassette Transfer function/Data Memory to Flash Memory Backup function (CP series)
PLC Model conversion
Connection with PLC directly
Communication with PLC directly
Auto Online to a PLC
Auto Online - EtherNet/IP Node Online
Communication with PLC on Network
Ethernet Connection Using UDP/IP
Connection with PLC
Ethernet Connection Using TCP/IP
Connection with PLC on
Network
Connecting Using EtherNet/IP
Connecting Using Controller Link Network Service Board
Connecting Using SYSMAC LINK Network Service Board
Connecting Using SYSMAC NET Network Service Board
Communication via modem
Simulator
Communication to Simulator
Format Memory card
Format EM file memory
File memory operation
Transfer Program file, Data file, and Parameter file between CPU unit and File memory
Transfer Symbol Files and Comment Files between CX-Programmer and File Memory
Delete file
Transfer (Copy) files between storages
*1. Ladder Support Software
*2. SYSMAC Support Software
*3. CV Support Software
*4. SYSMAC-CPT
4
CX-Programmer Ver.8
Category
Function
Create, Edit, Check IO Table
Verify/Compare IO Tables
Delete IO Table
Installing a CPS File (CS/CJ series)
Display/Write unit production information, unit text (CS/CJ series)
Display unit profile information (CS/CJ series)
IO Table
Set/Transfer/Compare Parameters for Special I/O Units and CPU Bus Units
Save Parameters for SIOU Units and CPU Bus Units (CS/CJ series)
Start Special Tool for SIOU Units and CPU Bus Units (CSCJ series)
Display each rack's power consumption (CS/CJ series)
Display rack width (CJ series)
Printing function
Display the Dip-switches status of the CPU Unit
Transfer program (Program, Rung Comment, Attached Comment, IO Table, PLC Settings, Symbol
Table, IO Memory, SIOU Unit Parameters)
Transfer program
Transfering in Task units
Verify program (Program, Function Block Body, SFC action, SFC transition, IO Table, IO Memory,
PLC setting)
Monitoring Ladder View
Monitoring Mnemonic View
Monitoring Structured Text program
Monitoring program
Monitoring SFC program
Monitoring SFC action, SFC transition, SFC subchart
Displaying Flash-ROM back up status
Monitoring Function Block Ladder View
Monitoring Function Block ST View
Set/Reset
Change current value
Force Set/Reset
Change Timer/Counter setting values
Differential monitor/Pause monitor
Online edit
Online editing of Function Block
Display errors and error logs occurring
Debug program
Data trace, Time chart monitor
Save result of data trace or time chart monitor
Display cycle time/ task execution time
Measure MARK instruction execution time (CV/CVM1 series)
Read Protection Using Passwords (CS/CJ/CP series)
Read Protection for Specific Tasks (CS/CJ/CP series)
System or partial protection (CV/CVM1 series)
Write Protection (CPM1/CPM1A, [email protected])
Password Protection of Function Bloks
Read/Set clock
Debugging by using a Simulator
Simulation
PLC-PT Integrated Simulation
PLC Error Simulator
Edit IO memory data
Edit/Monitor IO memory (Data memory)
Monitor IO memory data (PLC Memory window, Address monitor, Watch window, Ladder window,
Mnemonic window)
Verify/Transfer IO memory data
Find contacts of Force set/reset
Edit PLC settings
PLC settings
Transfer PLC settings
Verify PLC settings
Printing
5
CX-Programmer Ver.8
Category
Function
CX-Programmer project file (.CXP); A file containing the all user programs and parameter data
created by CX-Programmer. (The .CXP file is a compressed version of the .CXT file.)
CXT file (.CXT); A text-based format supported by CX-Programmer. The .CXT file format is used for
file conversions.
BAK file (.BAK); A backup copy of the project file.
Program file (.OBJ); It indicates full program area files.
Program index file (PROGRAMS.IDX); CX-Programmer section names, section comments, and
program comments.
File extension
Symbols file (SYMBOLS.SYM); CX-Programmer Global symbol tables, Local symbol tables, settings
for automatically allocated areas.
Comment file (COMMENTS.CMT); CX-Programmer rung comments and comments.
OPT file (.OPT); A file containing the preferences for the project.
CXO file (.CXO); A file containing the settings made on the Options dialog and the Watch window.
MAC file (.MAC); A file containing the keyboard mapping made on the Keyboard Mapping (Shortcut
Keys) dialog.
CX-Server file (.CDM); A file containing all of the information about the PLCs, which CX-Server can
connect to and the addresses of interest in each PLC which may be accessed. A new CX-Server
project can be created from the CX-Net Network Configuration tool.
Appendix
Ladder Section Window; It displays the Ladder program graphically. PLC program instructions can
be entered as a graphical representation in Ladder form.
View
Output Window;
• [Compile]; The Compile tab displays the output produced from program compilation. Selecting an
error highlights the source of the problem in the Ladder Diagram. The Compile tab also displays
other information, for example, warnings and connection messages.
• [Find Report]; The Find Report tab displays the output produced from a search of project files for
a articular entry.
• [Transfer]; The Transfer tab view displays the results of file or program loading.
Watch Window; It displays the value of the addresses of PLC memory during program execution.
Mnemonics View; The Mnemonics view is a formatted editor for programming in mnemonic
instructions.
ST Editor Window; Displays the ST language can be input directly.
SFC Editor Window; Displays an SFC chart or subchart.
Symbol Table Window; Displays an editable list of symbol definitions - the names, addresses and
comments.
6
CX-Programmer Ver.8
System Requirements
Item
Requirement
Operating system (OS) *1
Japanese or English system
Microsoft Windows 2000 (Service Pack 3 or higher) or XP
Microsoft Windows Vista *4
Computer
IBM PC/AT or compatible with a Pentium II 333 MHz
or faster processor (Pentium III 1 GHz or faster
recommended.)
IBM PC/AT or compatible with a processor recommended
by Microsoft. (1 GHz or faster recommended)
Memory
256 MB minimum *2
512 MB min. required.1 GB min. recommended.
Hard disk
Approx. 2.5 GB or more available space is required to install the complete CX-One package.
Display
SVGA (800 × 600) or better high-resolution display with 256 colors min.
Disk drive
CD-ROM drive or DVD-ROM drive
Communications ports
RS-232C port, USB port, or Ethernet port *3
Other
Internet access is required for online user registration, including a modem or other hardware connection method.
*1. CX-One Operating System Precaution
System requirements and hard disk space may vary with the system environment.
*2. The amount of memory required varies with the Support Software used in CX-One for the following Support Software. Refer to user
documentation for individual Support Software for details.
CX-Programmer, CX-Designer, CX-Thermo, CX-Simulator, CX-Protocol, CX-Motion, CX-Drive, CX-Process Tool, and Faceplate Auto-Builder
for NS
*3. An RS-232C port is required to connect the Support Software in CX-One to a PLC. If the computer provides only a USB port, use a CS1WCIF31 USB-to-RS-232C Conversion Cable. For connecting to the CP Series, however, an over-the-counter USB cable (type A-B) can be used.
For the CX-Drive, the CS1W-CIF31 USB-to-RS-232C Conversion Cable cannot be used to connect a USB port on the computer to the 3G3MV.
Use the recommended commercially available USB-serial conversion cable.
For details, refer to the CX-Drive Programmable Controller Operation Manual (Cat. No. W453).
*4. The following restrictions apply when CX-One is used with Microsoft Windows Vista.
1) Some Help files cannot be accessed.
The Help files can be accessed if the Help program distributed by Microsoft for Windows Vista (WinHlp32.exe) is installed. Refer to the
Microsoft homepage listed below or contact Microsoft for details on installing the file. (The download page is automatically displayed if the
Help files are opened while the user is connected to the Internet.)
http://support.microsoft.com/kb/917607/en-us
2) The following restrictions apply to some application operations.
Application
Restriction
CX-Designer
If a new Windows Vista font (e.g., Meiryo) is used in a project, the font size on labels may be bigger and protrude from the
components if the project is transferred from CX-Designer running on a Windows XP or earlier OS to the NS/NSJ.
CX-Process
When File Active Serial Port Driver is selected, a message stating that FinsGateway initialization failed may be displayed
and the serial driver may not be initialized.
7
CX-Programmer Ver.8
Applicable PLC Series
CX-Programmer can be used with SYSMAC CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series PLCs.
Applicable CPU Units
Series
CPU Unit
CS
CS1H-CPU63/64/65/66/67 (-V1)
CS1G-CPU42/43/44/45 (-V1)
CS1H-CPU63H/64H/65H/66H/67H
CS1G-CPU42H/43H/44H/45H
CS1D-CPU65H/67H
CS1D-CPU42S/44S/65S/67S
CJ
CJ1G-CPU44/45
CJ1H-CPU65H/66H/67H/64H-R/65H-R/66H-R/67H-R
CJ1G-CPU42H/43H/44H/45H
CJ1M-CPU11/12/13/21/22/23
CJ2H-CPU64-EIP/65-EIP/66-EIP/67-EIP/68-EIP
CJ2H-CPU64/65/66/67/68
CP
CP1H-XA40DR-A/XA40DT-D/XA40DT1-D/X40DR-A/X40DT-D/X40DT1-D/Y20DT-D
CP1L-M40DR-A/M40DR-D/M40DT-D/M40DT1-D/M30DR-A/M30DR-D/M30DT-D/M30DT1-D/M60DR-A/M60DR-D
/M60DT-D/M60DT1-D
CP1L-L20DR-A/L20DR-D/L20DT-D/L20DT1-D/L14DR-A/L14DR-D/L14DT-D/L14DT1-D/L10DR-A/L10DR-D/L10DT-D
/L10DT1-D
NSJ
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
[email protected]
C1000H
C1000H-CPU01
C2000H
C2000H-CPU01 Simplex system
C200H
C200H-CPU01/02/03/11/21/22/23/31
C200HX
C200HX-CPU34/44/54/64
C200HG
C200HG-CPU33/43/53/63
C200HE
C200HE-CPU11/32/42
C200HX-Z
C200HX-CPU34-Z/CPU44-Z/CPU54-Z/CPU64-Z/CPU65-Z/CPU85-Z
C200HG-Z
C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z
C200HE-Z
C200HE-CPU11-Z/CPU32-Z/CPU42-Z
C200HS
C200HS-CPU01/03/21/23/31/33
CPM1/CPM1A
CPM1 (A)-10CDR/20CDR/30CDR/40CDR (-V1)
[email protected]
CPM2A-20CD/30CD/40CD/60CD
CPM2C-10CD/10C1D/20CD/20C1D
[email protected]@
CPM2C-S100C/110C
CPM2C-S110C-DRT
CQM1
CQM1-CPU11/21/41/42/43/44/45
CQM1H
CQM1H-CPU11/21/51/61
CV1000
CV1000-CPU01 (-V1)
CV2000
CV2000-CPU01 (-V1)
CV500
CV500-CPU01 (-V1)
CVM1
CVM1-CPU01/1 (-V1)
CVM1-V2
CVM1-CPU01-V2/CPU11-V2/CPU21-V2
FQM1
FQM1-CM001/CM002 Coordinator module
FQM1-MMA21/MMA22/MMP21/MMP22 Motion control module
IDSC
IDSC-C1DR-A/C1DT-A
SRM1
SRM1-C01/C02 (-V1/-V2)
8
CX-Programmer Ver.8
Communication Method to Connect Applicable PLC and PC
Via USB
PC
USB A plug (female)
PLC
USB B plug (male)
Via RS-232C
PC
PC built-in RS-232C port
PLC
CPU unit built-in peripheral port
CPU unit built-in RS-232C port
Serial communication unil/board RS-232C port
Via Ethernet
PC
Ethernet port, Ethernet Card
PLC
Ethernet unit, EtherNet/IP Unit
Via Network Support Board
Controller Link
PC
Controller Link board
PLC
Controller Link unit
SYSMAC LINK
PC
SYSMAC LINK board
PLC
SYSMAC LINK unit
SYSNET
PC
SYSNET board
PLC
SYSNET unit
9
CX-Programmer Ver.8
Applicable Peripheral Devices
Connection Types for PLC and PC (CX-Programmer)
PLC Port
Connection
Types
PC port (CX-Programmer)
Conversion Cables (PLC)
A
USB B plug (male)
−
B
D-sub, 9-pin (female)
−
C
D-sub, 25-pin (female)
−
C Series peripheral
−
Connecting Cables
Commercially available
USB cable (A plug
connector (male) - B plug
connector (female))
[email protected]@@
Conversion Cables (PC)
−
USB A plug (female)
CS1W-CIF31 *
USB A plug (female)
[email protected]@@P-V
CS1W-CIF31 *
USB A plug (female)
CQM1-CIF02
CS1W-CIF31 *
CPM1-CIF01
USB A plug (female)
D
[email protected]@@S-V/S-CV
CPM1, CPM1A, CPM2A,
SRM1
CV500-CIF01
E
CV Series peripheral
−
F
CS/CJ/CP/CQM1H
peripheral
CS1W-CIF31 *
−
USB A plug (female)
CS1W-CN226/
CS1W-CN626
CS1W-CN118
[email protected]@@S-V/S-CV
CS1W-CN114
CQM1-CIF02
CS1W-CIF31 *
USB A plug (female)
* The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector.
Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer
2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for
individual PLCs for details.
10
CX-Programmer Ver.8
PLC Port
Connection
Types
PC port (CX-Programmer)
Conversion Cables (PLC)
−
Connecting Cables
Conversion Cables (PC)
CS1W-CN226/
CS1W-CN626
CPM2C-CN111
CS1W-CN114
CQM1-CIF02
CS1W-CN114
+CPM2C-CIF01-V1
CPM2C-CN111
CS1W-CIF31 *
G
CPM2C
USB A plug (female)
CS1W-CN118
CS1W-CN118
+CPM2C-CIF01-V1
[email protected]@@
CPM2C-CIF01-V1
CPM2C-CIF11
CPM2C-CIF21
* The CS1W-CIF31 is not required if the connector on the computer running the CX-Programmer has a D-sub, 9-pin male connector.
Note: 1. PC (Personal Computer) : IBM PC/AT or compatible computer
2. A Host Link Unit (e.g., C200H-LK201-V1) or Peripheral Interface Unit (C200H-IP007) is required for some PLCs. Refer to the tables for
individual PLCs for details.
11
CX-Programmer Ver.8
Connecting Cables for PLCs and PCs (CX-Programmer)
Conversion Cables for USB-D-Sub 9-pin
Unit
Computer
Unit port
−
PC port
RS-232C
PC/AT
D-sub, 9-pin (female) compatible
Network Type (Serial
Communications Mode)
USB A plug
Depends on the Unit's
connector (female) spcifications.
Model
CS1W-CIF31
Cable length
Connection
Types
−
0.5m
Connecting Cables for CJ2
Unit
Computer
Unit port
USB B plug
connector (male)
CPU Unit
PC port
PC/AT
compatible
Built-in RS-232C port
D-sub, 9-pin (female)
Network Type (Serial
Communications Mode)
USB A plug
USB or
connector (female) Toolbu (USB port)
D-sub, 9-pin (male) Host Link
Cable length
Connection
Types
Commercially
available USB cable
(A plug connector
(male) - B plug
connector (female))
5m maximum
A
XW2Z-500S-CV
5m
XW2Z-200S-CV
2m
Model
B
Connecting Cables for CS1/CJ1
Unit
Computer
Unit port
PC port
Network Type (Serial
Communications Mode)
2m
CS1W-CN626
6m
CS1W-CN118
+XW2Z-200S-CV
0.1m+2m
CS1W-CN118
+XW2Z-500S-CV
0.1m+5m
CS1W-CN118
+XW2Z-200S-V
0.1m+2m
CS1W-CN118
+XW2Z-500S-V
0.1m+5m
Host Link with a baud rate
of 19.2 kbps or less
CS1W-CN114
+CQM1-CIF02
0.05m+3.3m
Peripheral bus or Host
Link
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
Built-in peripheral
port
PC/AT
compatible
D-sub, 9-pin (male) Host Link
Built-in RS-232C port
D-sub, 9-pin (female)
Cable length
CS1W-CN226
Peripheral bus or Host
Link
CPU
Model
Host Link
Connection
Types
F
B
Connecting Cables for CP1H/CP1L
Unit
Computer
Unit port
PC port
USB B plug
connector (male)
CPU
RS-232C port (D-sub
9-pin female) on
Option Board
D-sub, 9-pin (female)
USB A plug
connector (male)
PC/AT
compatible
Network Type (Serial
Communications Mode)
USB
Peripheral bus or Host
Link
D-sub, 9-pin (male)
Host Link
Cable length
Connection
Types
Commercially
available USB cable
(A plug connector
(male) - B plug
connector (female))
5m maximum
A
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
Model
B
* An Option Board cannot be used with a CP1L CPU Unit with 10 Points.
Connecting Cables for NSJ
Unit
Computer
Unit port
PC port
USB B plug
connector (male)
USB A plug
connector (male)
PC/AT
compatible
CPU
Built-in RS-232C port
D-sub, 9-pin (female)
Network Type (Serial
Communications Mode)
USB
Peripheral bus or Host
Link
D-sub, 9-pin (male)
Host Link
Cable length
Connection
Types
Commercially
available USB cable
(A plug connector
(male) - B plug
connector (female))
5m maximum
A
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
Model
B
12
CX-Programmer Ver.8
Connecting Cables for C200HS
Unit
Computer
Unit port
PC port
Built-in peripheral
port
Peripheral bus or Host
Link
Built-in RS-232C port
D-sub, 9-pin (female)
PC/AT
(CPU 21/23/31/33
compatible
only)
CPU Unit
Host Link Unit C200HLK201-V1
Network Type (Serial
Communications Mode)
D-sub, 9-pin (male)
Host Link
Built-in RS-232C port
D-sub, 25-pin
(female)
Model
Cable length
Connection
Types
D
CQM1-CIF02
3.3m
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
XW2Z-200P-V
2m
XW2Z-500P-V
5m
B
C
Connecting Cables for C200HX/HG/HE
Unit
Computer
Unit port
PC port
Peripheral bus * or Host
Link
Built-in peripheral
port
CPU
Host Link Unit
C200H-LK201-V1
Network Type (Serial
Communications Mode)
Built-in RS-232C port
PC/AT
D-sub, 9-pin (female)
compatible
D-sub, 9-pin (male)
Host Link
Built-in RS-232C port
D-sub, 25-pin
(female)
Cable length
Connection
Types
CQM1-CIF02
3.3m
D
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
XW2Z-200P-V *
2m
XW2Z-500P-V *
5m
Model
B
C
* These Cables cannot be used for Programming Devices, such as the CX-Programmer, for the C200H-LK201-V1 Host Link Unit on a C200HX/
HG/HE-Z PLC.
Connecting Cables for CQM1H
Unit
Computer
Unit port
PC port
Network Type (Serial
Communications Mode)
Model
CS1W-CN226
Built-in peripheral
port
Peripheral bus or Host
Link
PC/AT
compatible
CPU
D-sub, 9-pin (male)
Built-in RS-232C port
D-sub, 9-pin (female)
Host Link
Cable length
Connection
Types
2m
CS1W-CN626
6m
CS1W-CN114
+CQM1-CIF02
0.05m+3.3m
CS1W-CN118
+XW2Z-200S-CV
0.1m+2m
CS1W-CN118
+XW2Z-500S-CV
0.1m+5m
CS1W-CN118
+XW2Z-200S-V
0.1m+2m
CS1W-CN118
+XW2Z-500S-V
0.1m+5m
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
F
B
Connecting Cables for CQM1
Unit
Computer
Unit port
PC port
Built-in peripheral
port
CPU
Built-in RS-232C port PC/AT
D-sub, 9-pin (female) compatible
(CPU42/43/44/63/64/
65/85 only)
Network Type (Serial
Communications Mode)
Peripheral bus or Host
Link
D-sub, 9-pin (male)
Host Link
Model
Cable length
Connection
Types
D
CQM1-CIF02
3.3m
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
B
13
CX-Programmer Ver.8
Connecting Cables for CPM1, CPM1A and CPM2A
Unit
Computer
Unit port
PC port
Network Type (Serial
Communications Mode)
Peripheral bus or Host
Link
CPU Unit
Built-in peripheral
port
PC/AT
compatible
D-sub, 9-pin (male)
Host Link
Model
Cable length
CPM1-CIF01
+XW2Z-200S-CV
2m
CPM1-CIF01
+XW2Z-500S-CV
5m
CPM1-CIF01
+XW2Z-200S-V
2m
CPM1-CIF01
+XW2Z-500S-V
5m
Connection
Types
D
* CPM2A CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) do not support Toolbus connections. They do support Host
Link connections.
Connecting Cables for SRM1
Unit
Computer
Unit port
PC port
Network Type (Serial
Communications Mode)
Peripheral bus or Host
Link
Built-in peripheral
port
PC/AT
compatible
CPU Unit
D-sub, 9-pin (male)
Host Link
Built-in RS-232C port
D-sub, 9-pin (female)
(SRM1-C01 only)
Model
Cable length
CPM1-CIF01
+XW2Z-200S-CV
2m
CPM1-CIF01
+XW2Z-500S-CV
5m
CPM1-CIF01
+XW2Z-200S-V
2m
CPM1-CIF01
+XW2Z-500S-V
5m
XW2Z-200S-CV
2m
XW2Z-500S-CV
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
Connection
Types
D
B
14
CX-Programmer Ver.8
Connecting Cables for CPM2C
Unit
Computer
Unit port
PC port
Peripheral bus *1 or Host
Link
Communications port
(as a peripheral port)
PC/AT
compatible
CPU
Communications port
(as an RS-232C port)
Network Type (Serial
Communications Mode)
D-sub, 9-pin (male)
Host Link
Model
Cable length
CS1W-CN226 *2
2m
CS1W-CN626 *2
6m
CS1W-CN114
+CQM1-CIF02
0.05m+3.3m
CPM2C-CIF01-V1
+CS1W-CN114
+CQM1-CIF02
Adapter+
0.05m + 3.3m
CPM2C-CN111
(Peripheral port)
+CQM1-CIF02
0.1m+3.3m
CS1W-CN118
+XW2Z-200S-CV
0.1m+2m
CS1W-CN118
+XW2Z-500S-CV
0.1m+5m
CPM2C-CN111
(RS-232C port)
+XW2Z-200S-CV
0.1m+2m
CPM2C-CN111
(RS-232C port)
+XW2Z-500S-CV
0.1m+5m
CPM2C-CIF01-V1
+XW2Z-200S-CV
Adapter+2m
CPM2C-CIF01-V1
+XW2Z-500S-CV
Adapter+5m
CPM2C-CIF01-V1
+CS1W-CN118
+XW2Z-200S-CV
Adapter
0.1m+2m
CPM2C-CIF01-V1
+CS1W-CN118
+XW2Z-500S-CV
Adapter
0.1m+5m
CS1W-CN118
+XW2Z-200S-V
0.1m+2m
CS1W-CN118
+XW2Z-500S-V
0.1m+5m
CS1W-CN111
(RS-232C port)
+XW2Z-200S-V
0.1m+2m
CS1W-CN111
(RS-232C port)
+XW2Z-500S-V
0.1m+5m
CPM2C-CIF01-V1
+XW2Z-200S-V
Adapter+2m
CPM2C-CIF01-V1
+XW2Z-500S-V
Adapter+5m
CPM2C-CIF01-V1
+CS1W-CN118
+XW2Z-200S-V
Adapter+
0.1m+2m
CPM2C-CIF01-V1
+CS1W-CN118
+XW2Z-500S-V
Adapter+
0.1m+5m
CPM2C-CIF11
+XW2Z-200S-V
Adapter+2m
CPM2C-CIF11
+XW2Z-500S-V
Adapter+5m
CPM2C-CIF21
+XW2Z-200S-V
Adapter+2m
CPM2C-CIF21
+XW2Z-500S-V
Adapter+5m
Connection
Types
G
*1. CPM2C CPU Units that have a 9 as the fourth digit of the lot number (4 or 5 digits) and that were manufactured in 1999 do not support Toolbus
connections. They do support Host Link connections.
*2. Only Host Link (SYSMAC WAY) connections are possible. Toolbus cannot be used.
Note: Refer to the CPM2C Operation Manual (Cat. No. W340) for details.
15
CX-Programmer Ver.8
Connecting Cables for C1000H, C2000H, C200H
Unit
Computer
Unit port
CPU Unit
Host Link Unit
C1000H, C2000H:
C500-LK203
C500-LK201-V1
(3G2A5-LK201-V1)
C120-LK201-V1
(3G2A6-LK201-EV1)
C200H:
C200H-LK201-V1
C120-LK201-V1
(3G2A6-LK201-EV1)
PC port
Network Type (Serial
Communications Mode)
Built-in peripheral
port
PC/AT
Built-in RS-232C port compatible
D-sub, 25-pin
(female)
Cable length
Connection
Types
C200H-IP007
+CQM1-CIF02
3.3m
D
XW2Z-200P-V
2m
Model
D-sub, 9-pin (male) Host Link
C
XW2Z-500P-V
5m
Connecting Cables for CVM1/CV
Unit
Computer
Unit port
PC port
Network Type (Serial
Communications Mode)
Built-in peripheral
port
CPU Unit
Built-in RS-232C port
D-sub, 9-pin (female)
Host Link Unit
CV500-LK201
(for full duplex
communication on
port 1)
Built-in RS-232C port
PC/AT
D-sub, 25-pin
compatible
(female)
Host Link Unit
CV500-LK201
(for full duplex
communication on
port 2)
Built-in RS-232C port
D-sub, 9-pin (female)
Cable length
Connection
Types
CV500-CIF01
6m
E
XW2Z-200S-V *
2m
XW2Z-500S-V *
5m
XW2Z-200P-V
2m
XW2Z-500P-V
5m
XW2Z-200S-V
2m
XW2Z-500S-V
5m
Model
B
C
D-sub, 9-pin (male) Host Link
B
* The XW2Z-200S-CV and XW2Z-500S-CV cannot be used.
Connecting Cables for C500
Unit
Computer
Unit port
CPU Unit *1
Built-in peripheral
port
Host Link Unit *2
C500-LK203
C500-LK201-V1
(3G2A5-LK201-EV1)
C120-LK201-V1
(3G2A6-LK201-EV1)
PC/AT
Built-in RS-232C port compatible
D-sub, 25-pin
(female)
PC port
Network Type (Serial
Communications Mode)
Cable length
Connection
Types
C200H-IP007
+CQM1-CIF02
3.3m
D
XW2Z-200P-V
2m
XW2Z-500P-V
5m
Model
D-sub, 9-pin (male) Host Link
C
*1. Production of the CPU Units was discontinued in March 2004.
*2. Production of the C500-LK203, C500-LK201-V1 (3G2A5-LK201-EV1), and C120-LK201-V1 (3G2A6-LK201-EV1) was discontinued in March
2006. (There is no recommended substitute product.)
Connecting Cables for C120
Unit
Computer
Unit port
CPU Unit *1
Host Link Unit *2
C120-LK201-V1
(3G2A6-LK201-EV1)
PC port
Network Type (Serial
Communications Mode)
Built-in peripheral
port
PC/AT
Built-in RS-232C port compatible
D-sub, 25-pin
(female)
D-sub, 9-pin (male) Host Link
Cable length
Connection
Types
C200H-IP007
+CQM1-CIF02
3.3m
D
XW2Z-200P-V
2m
XW2Z-500P-V
5m
Model
C
*1. Production of the CPU Units was discontinued in March 2003.
*2. Production of the C120-LK201-V1 was discontinued in March 2006. (There is no recommended substitute product.)
Connecting Cables for C20P/C28P/C40P/C60P*1, C20K/C28K/C40K/C60K*2
Unit
Computer
Unit port
Host Link Unit *3 *4
C20-LK201-V1
(3G2C7-LK201-EV1)
Built-in RS-232C port
PC/AT
D-sub, 25-pin
compatible
(female)
PC port
Network Type (Serial
Communications Mode)
D-sub, 9-pin (male) Host Link
Model
Cable length
XW2Z-200P-V
2m
XW2Z-500P-V
5m
Connection
Types
C
*1. Production of the C20P, C28P, C40P, and C60P CPU Units was discontinued in March 2002.
*2. Production of the C20K, C28K, C40K, and C60K CPU Units was discontinued in March 2002.
*3. For connection to [email protected]@P PLCs, a Host Link Unit is also required in addition to a Connecting Cable.
*4. Production of the C20-LK201-V1 (3G2C7-LK201-EV1) was discontinued in March 2006. (There is no recommended substitute product.)
16
CX-Programmer Ver.8
Related Manuals
Cat.No.
Model
Manual name
Contents
W446
[email protected]
CX-Programmer [email protected]
Operation Manual
Provides information on how to use the CX-Programmer for all functionality except for
function blocks.
W447
[email protected]
CX-Programmer Ver. [email protected]
Operation Manual Function
Blocks/Structured Texts
Describes the function block functions and structured text programming functions that can
be used with the CX-Programmer version [email protected] For details on other CX-Programmer
functions, refer to the CX-Programmer Ver. [email protected] Operation Manual (Cat. No.W446).
W469
[email protected]
CX-Programmer
Operation Manual: SFC
Explains how to use the SFC programming functions. For explanations of other shared
CX-Programmer functions, refer to the CX-Programmer Operation Manual (W446).
W463
[email protected]@C-V3/
[email protected]@D-V3
CX-One Setup Manual
Installation and overview of CX-One FA Integrated Tool Package.
W445
[email protected]@C-V3/
[email protected]@D-V3
CX-Integrator
Operation Manual
Describes the operating procedures for the CX-Integrator.
17
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2009.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2009 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
3G2C7-LK201-EV1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement