AMP-200-EUR Series TRMS Clamp Meters

AMP-200-EUR Series TRMS Clamp Meters
www.Beha-Amprobe.com
AMP-200-EUR Series
TRMS Clamp Meters
The Modern Evolution of the Professional Clamp Meter
Beha-Amprobe’s AMP-210-EUR and AMP-220-EUR 600 A TRMS Clamp
Meters offer a complete range of measuring functions for today’s modern
electrical environments. Both models feature True-RMS sensing, low pass
filters and fast response processors for quick, error-free measurements.
The Amp-Tip function allows for precise measurement of current down
to the tenth of an Amp, enabling accurate current measurement of both
large and small diameter wires.
AMP-200-EUR
Series Features
• True-RMS
• Low Pass Filter
• Amp-Tip Functions
• Non-Contact Voltage
Detection (NCV)
• Audible Continuity and
Diode Test
• Data Hold, Relative Zero
• Large LCD Backlit
Display
• Safety Rated:
CAT III 600 V
AMP-210-EUR
AC Clamp Meter
Beha-Amprobe® | In den Engematten 14 | 79286 Glottertal, Germany | Tel: +49 (0) 7684 8009-0 | [email protected] | www.Beha-Amprobe.com
AMP-220-EUR
AC/DC Clamp Meter
©2014 Beha-Amprobe® 13253-eng
www.Beha-Amprobe.com
AMP-200-EUR Series Product Details
True-RMS for accurate
voltage measurements in
noisy environments.
Low pass filter
for current and voltage
measurements on variable
frequency drives.
Amp-Tip function
for precise low current
measurement of small
diameter wires down to 0.1
Amp to help with electrical
system troubleshooting.
Non-contact voltage
detection (NCV)
Measurements:
Audible continuity and
diode test
Data hold, relative zero,
MAX/MIN/AVG mode
Large LCD backlit
display
Voltage
Up to 600 V AC/DC
Resistance
Up to 60.00 kΩ
AC current
Up to 600 A
Capacitance
Up to 2500 µF
DC Current
Up to 600 A
(AMP-220-EUR only)
Frequency
5.00 to 999.9 Hz
Safety rated
CAT III 600 V
AMP-200-EUR Series Applications
AMP-210-EUR AC Clamp Meter
• Accurate measurement of current, voltage
and frequency on all electrical systems including
distorted, non-sinusoidal signals (True-RMS function)
and variable frequency drives (low-pass filter).
• Capacitance measurement for start and run
motor capacitors.
AMP-220-EUR AC/DC Clamp Meter
• Low pass filter allows measurement of current
and voltage on variable frequency drives (motors
with speed controlled by frequency). Without this
feature, the meter would provide erroneous readings
when measuring voltage and current.
• Resistance and continuity functions to verify
quality of electrical connections and to check if
motor and transformer coils are working properly.
Beha-Amprobe® | In den Engematten 14 | 79286 Glottertal, Germany | Tel: +49 (0) 7684 8009-0 | [email protected] | www.Beha-Amprobe.com
©2014 Beha-Amprobe® 13253-eng
www.Beha-Amprobe.com
AMP-200-EUR and AMP-300-EUR
Detailed Specifications
Model
AMP-210-EUR
AMP-220-EUR
AMP-310-EUR
AMP-320-EUR
AMP-330-EUR
AC Clamp Meter
Electrical
AC/DC Clamp Meter
Electrical
AC Clamp Meter
HVAC
AC/DC Clamp Meter
Electrical Motor
Maintenance
AC/DC 1000 A Clamp Meter
Industrial Motor Maintenance
CAT IV 600 V, CAT III 1000 V
Safety Rating
CAT III 600 V
CAT III 600 V
CAT III 600 V
CAT III 600 V
Jaw Opening
1.18 in (30 mm)
1.37 in (35 mm)
1.18 in (30 mm)
1.37 in (35 mm)
2.0 in (51 mm)
AC Voltage
(True-RMS)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD (50 to 60 Hz)
±1.5% + 5LSD (20 to 200 Hz)
±10% + 5LSD (200 to 400 Hz)
DC Voltage
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD
AC+DC Voltage
–
Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD
(DC, 50 to 60 Hz)
Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
AC Current
(True-RMS)
DC Current
AC+DC Current
Precise Low
Current AC
Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD (40 to 100 Hz)
±2.2% + 5LSD (100 to 400 Hz)
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
–
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD
–
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to
400 Hz)
–
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)
Range: 0 to 1000 A
Accuracy: ±2.2% + 7LSD (DC, 40 to 100 Hz)
±2.5% + 7LSD (100 to 400 Hz)
–
Precise Low
Current AC+DC
Range: 0 to 1000 V
Accuracy: ±1.0% + 7LSD (50 to 60 Hz)
±1.8% + 7LSD (DC, 40 to 200 Hz)
±12% + 7LSD (200 to 400 Hz)
Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD (DC, 50
to 60 Hz)
–
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
Precise Low
Current DC
–
–
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
Range: 0 to 60.00 A
Accuracy:
±1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz)
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz)
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
–
–
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A)
±3.0% + 5LSD (20.00 to 60.00 A)
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
Range: 0 to 60.00 A
Accuracy:
±2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100
Hz)
±2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100
Hz)
±3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz)
Frequency
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Resistance
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
ON ≤ 10 Ω
OFF > 250 Ω
ON ≤ 10 Ω
OFF > 250 Ω
20 to 440 V, 50/60 Hz
20 to 440 V, 50/60 Hz
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (1000 V range)
Range: 40.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (1000 A range)
Continuity
Beeper
Non-Contact
Voltage
True-RMS
•
•
•
•
•
Low Pass Filter
•
•
•
•
•
Autoranging
•
•
•
•
•
Relative Zero
•
•
•
•
•
MAX/MIN/AVG
•
•
•
•
•
Diode Test
•
•
•
•
•
Data Hold
•
•
•
•
•
Backlight
•
•
•
•
•
Auto Power Off
•
•
•
•
•
–
–
Range: 0.0 to 2000 µA
Accuracy: ±1.0% + 5LSD
–
–
Range: -40.0 to 752°F, -40.0 to 400°C
Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F)
100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C)
>-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C)
3-Phase and
Motor Rotation
Indication
–
–
Rotation-R for mains supply
Rotation-M for motors
Inrush Current
–
–
•
•
•
Peak Hold (Crest)
–
–
–
–
•
Work Light
–
–
–
–
•
AMP-300-EUR Series:
DC Microamps
Temperature*
(Type K
thermocouple)
*Error does not
include Type-K
thermocouple errors
Beha-Amprobe | In den Engematten 14 | 79286 Glottertal, Germany | Tel: +49 (0) 7684 8009-0 | [email protected] | www.Beha-Amprobe.com
®
©2014 Beha-Amprobe® 13253-eng
AMP-200-EUR and AMP-300-EUR
General Specifications
Model
AMP-210-EUR
AMP-220-EUR
AMP-310-EUR
AMP-320-EUR
AMP-330-EUR
Display
3-5/6 digits 6000 counts
3-5/6 digits 6000 counts
3-5/6 digits 6000 counts
3-5/6 digits 6000 counts
3-5/6 digits 6000 counts
Polarity
Automatic
Automatic
Automatic
Automatic
Automatic
Update Rate
5 per second nominal
5 per second nominal
5 per second nominal
5 per second nominal
5 per second nominal
Operating
Temperature
32 to 104°F (0 to 40°C)
32 to 104°F (0 to 40°C)
32 to 104°F (0 to 40°C)
32 to 104°F (0 to 40°C)
14 to 122°F (-10 to 50°C)
Relative Humidity
80% at 30°C, 50% at 40°C
80% at 30°C, 50% at 40°C
80% at 30°C, 50% at 40°C
80% at 30°C, 50% at 40°C
Non condensing at ≤10°C
90% at 10 to30°C
75% at 30 to 40°C
45% at 40 to 50°C
Operating Altitude
0 to 2000 m
0 to 2000 m
0 to 2000 m
0 to 2000 m
0 to 2000 m
2
2
2
2
2
Storage
Temperature
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
-4 to 140°F (-20°C to 60°C),
< 80% RH
Temperature
Coefficient
Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C
or 28°C to 40°C)
Nominal 0.15 x (specified
accuracy)/ °C @ (0°C to 18°C or
28°C to 40°C)
Nominal 0.10 x (specified accuracy)/
°C @ (0°C to 18°C or 28°C to 50°C)
Battery
Two AAA 1.5 V battery
Two AAA 1.5 V battery
Two AAA 1.5 V battery
Two AAA 1.5 V battery
Two AA 1.5 V battery
EMC
Meets EN 61326-1:2006
Meets EN 61326-1:2006
Meets EN 61326-1:2006
Meets EN 61326-1:2006
Meets EN 61326-1:2006
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0,
IEC/EN 61010-2-033 ed. 1.0,
CAN/CSA C22.2 NO. 61010-1
ed. 3.0, IEC/EN 61010-2-032
ed. 3.0 & IEC/EN 61010-031
ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0, IEC/
EN 61010-2-033 ed. 1.0, CAN/CSA
C22.2 NO. 61010-1 ed. 3.0, IEC/
EN 61010-2-032 ed. 3.0 & IEC/EN
61010-031 ed. 1.1
UL/IEC/EN 61010-1 ed. 3.0, IEC/EN
61010-2-033 ed. 1.0, CAN/CSA C22.2
NO. 61010-1 ed. 3.0, IEC/EN 61010-2032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1
Certification
UL (c/us) and CE
UL (c/us) and CE
UL (c/us) and CE
UL (c/us) and CE
UL (c/us) and CE
Dimensions
(L x W x H):
8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)
8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)
8.62 x 3.03 x 1.46 in
(219 x 77 x 37 mm)
8.82 x 3.03 x 1.46 in
(224 x 77 x 37 mm)
10.16 x 3.70 x 1.73 in
(258 x 94 x 44 mm)
208 g (0.46 lb)
254 g (0.56 lb)
208 g (0.46 lb)
254 g (0.56 lb)
420 g (0.93 lb)
User’s Manual
•
•
•
•
•
Test Leads
•
•
•
•
•
Carrying Case
•
•
•
•
•
Pollution Degree
Safety Compliance
Weight:
Accessories
Included:
Batteries
AAA (2)
AAA (2)
AA (2)
Alligator Clip Set
–
–
•
•
•
Banana plug K-type
Thermocouple
–
–
•
•
•
www.Beha-Amprobe.com
Beha-Amprobe® | In den Engematten 14 | 79286 Glottertal, Germany | Tel: +49 (0) 7684 8009-0 | [email protected] | www.Beha-Amprobe.com
©2014 Beha-Amprobe® 13253-eng
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement