Untitled - sinpec power system work in progress
INDEX
PAGE
LEGEND
02
NOTES
03
PROFESSIONAL SERIES
NX 3-14 kVA
05
NX TT 10-40 kVA
06
INDUSTRIAL & CUSTOM SERIES
HP-G 10÷1000 kVA - INDOOR & OUTDOOR
08
HP-M 10÷300 kVA - MODULAR UPS
13
STATIC TRANSFER SWITCH
15
FC AVIO FREQUENCY CONVERTER 400Hz
16
Z NO-BREAK Emergency Light & Pump UPS
17
SS NO-BREAK Emergency Light & Motor UPS
18
RES DC BRANCH RECTIFIER - DC UPS
19
LCD BRANCH RECTIFIER - DC UPS
21
PLATINUM S BRANCH RECTIFIER - DC UPS
23
PLATINUM D BRANCH RECTIFIER - DC UPS
25
INDUSTRIA BRANCH RECTIFIER - DC UPS
27
CONSUMER SERIES
COMPACT ST 0,6-1,6 kVA
30
HT TOWER 1-3,4 kVA
31
HT RACK 19 1-3 kVA
32
HT-B 6-10 kVA
33
HT-C 10-600 kVA
34
VARIOUS
MEC VOLTAGE REGULATORS
41
PV SYSTEM - SOLAR
42
POWER GENERATOR
46
BATTERIES
46
HARMONIC COMPENSATION PASSIVE SYSTEM
46
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
LEGEND
VOLTAGE & FREQUENCY
UPS LINE
INTERACTIVE
VOLTAGE
INDEPENDENT
UPS ON-LINE
UPS AC-SYSTEM
VOLTAGE
FREQUENCY
INDEPENDENT
VOLTAGE
FREQUENCY
INDEPENDENT
INPUT & OUTPUT
INPUT
&
OUTPUT
SINGLE PHASE
INPUT
&
OUTPUT
THREE PHASE
INPUT
SINGLE PHASE
INPUT
THREE PHASE
OUTPUT
THREE PHASE
OUTPUT
SINGLE PHASE
INPUT:
SINGLE PHASE
or
THREE PHASE
OUTPUT:
SINGLE PHASE
INPUT:
SINGLE PHASE
or
THREE PHASE
OUTPUT:
SINGLE PHASE
or
THREE PHASE
INPUT
SINGLE PHASE
OUTPUT
Vdc
(Direct Current)
INPUT:
SINGLE PHASE
or
THREE PHASE
OUTPUT:
THREE PHASE
INPUT
SINGLE PHASE
or
THREE PHASE
OUTPUT
Vdc
(Direct Current)
APPLICATIONS
SINPEC_CT1501 DOMESTIC
&
OFFICE
DATA CENTER
AIRPORT
HOSPITAL
SEAPORT
TRAIN
PETROLCHEMIC
INDUSTRY
METRO
EMERGENCY
BANK
CCTV - VIDEO
SURVEILLANCE
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
2of46
NOTE
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
3of46
PROFESSIONAL SERIES
NX
NX TT
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
NX
FUNCTIONS AND FEATURES
→ True On-Line Double Convertion with transformer
→ High frequency IGBT Inverter
→ Monophase or threephase ( option ) input
→ Monophase output
→ High AC/AC efficiency
→ PFC circuit on the input
→ Microprocessor control
→ Automatic by-pass included
→ LCD Display for information about UPS status
→ Fail self-test
→ Automatic and manual battery test
→ Communication port RS-232 and software
→ Suitable for any type of utilization
→ Double or more autonomy in the standard box or with extension battery box
under the UPS
NX
Options:
→ Interface dry contacts
→ USB interface
→ SNMP adapter with Software
→ Remote control panel
→ Dry alarm and status contact board
→ Manual by-pas
→ Emergency Power Off ( EPO )
→ First starting also without line
→ available as an emergency system (SA/SE o ECO )
→ Voltage Converter and/or Frequency
More autonomy on request
NX MODEL
POWER
NX RACK
30
40
55
70
100
140
(kVA)
3
4
5
7
10
14
(kW)
2,1
3
4
5
7,5
10
VOLTAGE
INPUT
230 Vac ± 20%
230 Vac ± 20% (OPT. THREE PHASE)
FREQUENCY
50 - 60 Hz ± 5%
> 0,98
POWER FACTOR
230 Vac ± 5%
VOLTAGE
50 - 60 Hz ± 0,005%
FREQUENCY
OUTPUT
110% for 60 sec. - 130% for 10 sec. – SHORTCIRCUIT MANAGEMENT
OVERLOAD
PURE SINUWAVE
WAVE FORM
< 3% (W/ LINEAR LOAD)
THD
91% - on ECO Mode >98%
EFFICIENCY
12 V - 7 Ah
TYPE
BATTERY
NUMBER
10
12 V - 12 Ah
12
16
FROM 40 dBA TO 60 Dba (@ 1 m)
OPERATING TEMPERATURE
FROM 0°C TO 40°C
<95% NOT CONDENSING
RELATIVE HUMIDITY ( @35°C)
DIMENSIONS UPS RACK (WxDxH) mm
ELECTRONIC
PROTECTIONS ELECTRIC
MECHANICAL
SIGNALLING
320x650x650
420x850x670
483x475x355 (5U+3U)
-
DIMENSIONS UPS (WxDxH) mm
STANDARDS
OPTIC
ACOUSTIC
20
8h
NOISE LEVEL
WEIGHT (Kg)
20
15'
STD. BACK UP
RECHARGE TIME
GENERAL
NOTES
20
90
95
113
132
180
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
195
OVERLOAD - SHORTCIRCUIT - BATTERY LOW
INPUT & BATTERY FUSES - AUTOMATIC SWITCH ON OUTPUT
IP21
UPS STATUS/OPERATION, OVERLOAD, MIN. BATTERY LEVEL
POWER FAILURE - LOW BATTERIES - OVERLOAD - START BATTERY TEST
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES, LABORATORIES,
BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
5 of 46
NX TT
FUNCTIONS AND FEATURES
→ True On-Line Double Convertion
→ High frequency IGBT Inverter
→ Threephase input
→ Threephase output
→ High AC/AC efficiency
→ PFC circuit on the input
→ Microprocessor control
→ Automatic and Manual by-pass included
→ Emergency Power Off ( EPO )
→ LCD Display for information about UPS status
→ Fail self-test
→ Automatic and manual battery test
→ Communication 2 port RS-232
→ Suitable for any type of utilization
NEX
Options:
→ Isolationt transformer
→ Interface dry contacts
→ USB interface
→ SNMP adapter with Software
→ Remote control panel
→ Dry alarm and status contact board
→ First starting also without line
→ available as an emergency system (SA/SE o ECO )
→ Parallel Unit configuration
More autonomy in external Box on request
NX TT CP from 10 at 25 Kva
nx tt compact - small chasis
NX TT MODEL
POWER
INPUT
100
150
200
250
300
400
(kVA)
10
15
20
25
30
40
(kW)
8
12
16
20
24
32
VOLTAGE
380/400/415Vac +/-15% 3ph+ N + G
FREQUENCY
380/400/415Vac +/-15% 3ph+ N + G
50 - 60 Hz ± 5%
> 0,95
POWER FACTOR
110% FOR 5 MIN. - 150% FOR 5 SEC. - ANGLE PHASE DISPLACEMENT (TENSIONS) 120° +/-1%
VOLTAGE
50 - 60 Hz ± 0,005%
FREQUENCY
OUTPUT
0
OVERLOAD
PURE SINUWAVE
WAVE FORM
< 3% (W/ LINEAR LOAD)
THD
91% - on ECO Mode >98%
EFFICIENCY
12 V - 7,2 or 9Ah
TYPE
BATTERY
12 V - 7,2 or 9 or 24Ah
32 or 32 x2 (TT CP)
NUMBER
32 24Ah or 32 x2
15'
STD. BACK UP
8h
RECHARGE TIME
FROM 40 dBA TO 60 Dba (@ 1 m)
NOISE LEVEL
FROM 0°C TO 40°C
<95% NOT CONDENSING
OPERATING TEMPERATURE
GENERAL
NOTES
RELATIVE HUMIDITY ( @35°C)
455x905x985
DIMENSIONS UPS TT CP (WxDxH) mm
550x700x1250
DIMENSIONS UPS TT (WxDxH) mm
WEIGHT W/O BATTERY(Kg)
STANDARDS
ELECTRONIC
PROTECTIONS ELECTRIC
MECHANICAL
SIGNALLING
NX TT from 10 at 40 Kva
nx tt big chasis
OPTIC
ACOUSTIC
145CP - 180
550x930x1250
150CP - 185
155CP - 190
160CP - 195
200
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
205
OVERLOAD - SHORTCIRCUIT - BATTERY LOW
BATTERY FUSES - INPUT & OUTPUT SWITCH
IP21
UPS STATUS/OPERATION, OVERLOAD, MIN. BATTERY LEVEL
POWER FAILURE - LOW BATTERIES - OVERLOAD - START BATTERY TEST
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
6 of 46
INDUSTRIAL & CUSTOM SERIES
HP-G
HP-M
STS
FC AVIO
AC UPS EMERGENCY
DC OUT UPS
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
HP-G Series
FUNCTIONS AND FEATURES
HP-G Series designed for heavy duty rugged environments,
applications suited for Chemical plants , Refinery , Power substation ,
airports and railways stations., Oil & Gas offshore and Onshore,
petrolchemical, Hospitals and healthcare, Security.
The units provide a full insulation of the critical load from the mains in
order to ensure a full power . Availability and reliability over an heavy
polluted mains line supply , protecting the load from mains dip, sags
and heavy harmonic disturbance .
HP-G Series meets the L.U. specification NR_PS_ELP_0007_ISS_3.
Full customized system solution in order to meet every Customer’s
request over the power protection field .
Units are fully designed and manufactured in Italy since Y 2001 and
the production process is fully compliant with ISO9001-2008.
HOW IT WORKS
NORMAL OPERATION
The rectifier with input
p isolation transformer converts input
p AC mains into stabilized and filtered DC suitable to feed the inverter and recharge
g the
battery bank . The inverter is supplied from the rectifier and will reproduce a pure sinusoidal waveform that through the output isolation transformer
and the static switch is feed into the load.
LOSS OF INPUT POWER
In the event of mains failure, the inverter will drain energy from the DC battery until the low DC threshold is reached or the mains input is restored.
When the mains input is restored, the rectifier will provide the DC supply for the inverter and simultaneously recharging the battery. The critical load
connected to the inverter and the critical DC load connected to the rectifier will not be affected during mains failure and restoring.
BYPASS OPERATION
The UPS is provided with a current sensing circuit which can detect overloads and sustain according with the specification overloads and output short
circuits. The UPS current protection circuit causes the static switch to transfer the critical load to the bypass line without interruption . It is also
possible to fit an isolation transformer and AVR in order to make bypass line clean and stable across mains fluctuations and disturbances.
WHY USE IT
LOAD SUPPLY IS SAFE AGAINST MAINS FAILURE
HP-G Series provides a full load insulation by means of galvanic transformer , so where the load is likely to be affected by a very large variation on
power supply, a transformer based UPS provides a safer and more reliable solution than transformer-less technology UPS . Also the output
transformer provides a true protection under heavy inverter failure , stopping unwanted DC current flow to the critical load . For several critical
applications ( i.e. oil & gas or health care ), redundancy on the rectifier side and on the inverter side is highly recommended in order to maximize
MTBF and reduce the MTTR in case of failure.
LOAD SECURITY AGAINST BATTERY AND RECTIFIER FAILURE
Ups systems are developed to provide a proper care regarding backup battery blocks and ensure long life terms and proper recharging current and
voltage level according to the environmental condition terms . This result in less maintenance on the unit and more availability of the system.
MODULAR ARCHITECTURE
UPS units systems can be manufactured with modular architecture, in order to fulfill the increase power demand on site , increasing reliability and
availability of the output power supply used for critical loads .
SOLUTION FOR INDUSTRIAL APPLICATIONS
Transformer-based devices are ideal for applications that experience heavily polluted mains supplies , particularly industrial, rural and complex
infrastructure locations, such as hospitals, petroleum plants and airports. In these circumstances, any UPS would be expected to provide long-term
protection from repetitive transients and electrical noise – dip-sags without degradation of the energy supplied to the load .
BATTERY EFFICIENCY
Unlike transformer-less systems, HP-T UPS systems use fewer number of battery sets to feed the load . HP-G Industrial UPS Systems come with
110VDC, 144 VDC, 220 VDC, 264 VDC or 360 VDC bus bar ratings with up to 500 Amp charging capacity.
LONG TERM OPERATIONAL EFFICIENCY
HP-G transformer based, double conversion online UPS systems provide longer operational efficiency compared with transformer-less UPS
systems . Easy maintenance and friendly user interface –with
with a 10 Y production background makes HP-G
HP G one of the most reliable and cost effective
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
8 of 46
HP-G Series
FUNCTIONS AND FEATURES
The units provide a full insulation of the critical load from the mains in
order to ensure a full power availability and reliability over an heavy
polluted mains line supply , protecting the load from mains dip, sags and
heavy harmonic disturbance.
Units meets the L.U. specification NR_PS_ELP_0007_ISS_3.
Designed and manufactured in Italy since Y 2001 and the production
process is fully compliant with ISO9001-2008.
HP-G Series are primarily designed to meet requirements for the following
applications :
• Oil & Gas offshore and Onshore
• Petrochemical
• Chemical
• Power and Substations
• Production process plants
• Offshore installations
• Pumping control centers
• Airport - avionics and airfields
• Railways and metro lines
• Hospitals and healthcare
• Security and alarm equipments
• Isolation transormer
• Rectifier 6 to 12 pulses with thyristor
• IGBT Inverter configuration, PWM control
• Bridge IGBT interter
Options:
Customizable UPS
More autonomy on request
HP-G MODEL
POWER
(kVA)
(kW)
15
20
30
40
50
15
20
30
40
50
8
12
16
24
32
40
380-400-415-440 VAC 3PH (3WIRE + G) 6 PULSE TYRISTOR RECTIFER (OPTION 12 PULSE)
VOLTAGE
INPUT
10
10
50/60 HZ 10% SELECTABLE
FREQUENCY
0 85 LAGGING TYPICAL @100% LOAD 400VAC (0,91
0,85
(0 91 FOR 12 PULSE)
POWER FACTOR
380-400-415-440 VAC 3PH (3WIRE + G) WITH ISOLATION TRASFORMER
VOLTAGE
50/60Hz +/-0.01%
FREQUENCY
OUTPUT
125% FOR 10 MINUTES - 150% FOR 60 SECONDS
OVERLOAD
TRUE SINE WAVE (IGBT PWM CONTROLLED)
WAVE FORM
2% WITH 100% LINEAR LOAD - 5% WITH 80% NON LINEAR LOAD (IEC62040)
THD
92% AT 100% LOAD
EFFICIENCY
COMMON WITH RECTIFIED (DEFAULT) OR DUAL INPUT
INPUT CONFIGURATION
BY-PASS
10% OF NOMINAL OUTPUT VOLTAGE (ADJUSTABLE)
TRANSFER LIMIT
110% CONTINUOUS
OVERLOAD CAPABILITY
INTERNAL MAINTENANCE BY-PASS
MANUAL
BATTERY
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE
192 (LEAD-ACID)
NUMBER
55
NOISE LEVEL
32F-104F (0°C - 40°C)
OPERATING TEMPERATURE
0-95% NON CONDENSING
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
REDUNDANT FANS - AIR FORCED
COOLING SYSTEM
CONFIGURATION STANDARD
DIMENSIONS UPS (WxDxH) mm
COMUNICATION
650x680x1400
650x680x1400
650x680x1400
IP20 INDOOR (OPTION IP OUTDOOR)
LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANEL-TOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
BATTERY EXTENSION
TRANSFORMER ISOLATION
INVERTER BRIDGE
650x680x1400
UL1778,IEC62040,ISO9001,EN52001
STANDARDS
OTHERS
550x680x1400
1X RS232 - E.P.O. - ALLARM CONTACT (VOLTAGE FREE) - EXTERNAL AUX CONTACT FOR THE BY-PASS SWITCH
PROTECTIONS MECHANICAL
SIGNALLING
STAND ALONE (OPTION PARALLEL CAPABILITY UP FOUR UNITS REDUNDANCY-CAPACITY)
550x680x1400
YES
YES
IGBT TECHNOLOGY
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
9 of 46
HP-G Series
FUNCTIONS AND FEATURES
The units provide a full insulation of the critical load from the mains in
order to ensure a full power availability and reliability over an heavy
polluted mains line supply , protecting the load from mains dip, sags and
heavy harmonic disturbance.
Units meets the L.U. specification NR_PS_ELP_0007_ISS_3.
Designed and manufactured in Italy since Y 2001 and the production
process is fully compliant with ISO9001-2008.
HP-G Series are primarily designed to meet requirements for the following
applications :
• Oil & Gas offshore and Onshore
• Petrochemical
• Chemical
• Power and Substations
• Production process plants
• Offshore installations
• Pumping control centers
• Airport - avionics and airfields
• Railways and metro lines
• Hospitals and healthcare
• Security and alarm equipments
• Isolation transormer
• Rectifier 6 to 12 pulses with thyristor
• IGBT Inverter configuration, PWM control
• Bridge IGBT interter
Options:
Customizable UPS
More autonomy on request
HP-G MODEL
POWER
(kVA)
(kW)
80
100
120
150
200
80
100
120
150
200
48
64
80
96
130
160
380-400-415-440 VAC 3PH (3WIRE + G) 6 PULSE TYRISTOR RECTIFER (OPTION 12 PULSE)
VOLTAGE
INPUT
60
60
50/60 HZ 10% SELECTABLE
FREQUENCY
0 85 LAGGING TYPICAL @100% LOAD 400VAC (0,91
0,85
(0 91 FOR 12 PULSE)
POWER FACTOR
380-400-415-440 VAC 3PH (3WIRE + G) WITH ISOLATION TRASFORMER
VOLTAGE
50/60Hz +/-0.01%
FREQUENCY
OUTPUT
125% FOR 10 MINUTES - 150% FOR 60 SECONDS
OVERLOAD
TRUE SINE WAVE (IGBT PWM CONTROLLED)
WAVE FORM
2% WITH 100% LINEAR LOAD - 5% WITH 80% NON LINEAR LOAD (IEC62040)
THD
92% AT 100% LOAD
EFFICIENCY
COMMON WITH RECTIFIED (DEFAULT) OR DUAL INPUT
INPUT CONFIGURATION
BY-PASS
10% OF NOMINAL OUTPUT VOLTAGE (ADJUSTABLE)
TRANSFER LIMIT
110% CONTINUOUS
OVERLOAD CAPABILITY
INTERNAL MAINTENANCE BY-PASS
MANUAL
BATTERY
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE
192 (LEAD-ACID)
NUMBER
55
NOISE LEVEL
32F-104F (0°C - 40°C)
OPERATING TEMPERATURE
0-95% NON CONDENSING
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
REDUNDANT FANS - AIR FORCED
COOLING SYSTEM
CONFIGURATION STANDARD
DIMENSIONS UPS (WxDxH) mm
COMUNICATION
1060x1060x2000 1060x1060x2000 2060x1060x2000
IP20 INDOOR (OPTION IP OUTDOOR)
LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER OPTIONAL GRAPHICAL PANEL-TOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
BATTERY EXTENSION
TRANSFORMER ISOLATION
INVERTER BRIDGE
860x860x2000
UL1778,IEC62040,ISO9001,EN52001
STANDARDS
OTHERS
860x860x2000
1X RS232 - E.P.O. - ALLARM CONTACT (VOLTAGE FREE) - EXTERNAL AUX CONTACT FOR THE BY-PASS SWITCH
PROTECTIONS MECHANICAL
SIGNALLING
STAND ALONE (OPTION PARALLEL CAPABILITY UP FOUR UNITS REDUNDANCY-CAPACITY)
860x860x2000
YES
YES
IGBT TECHNOLOGY
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
10 of 46
HP-G Series
FUNCTIONS AND FEATURES
The units provide a full insulation of the critical load from the mains in
order to ensure a full power availability and reliability over an heavy
polluted mains line supply , protecting the load from mains dip, sags and
heavy harmonic disturbance.
Units meets the L.U. specification NR_PS_ELP_0007_ISS_3.
Designed and manufactured in Italy since Y 2001 and the production
process is fully compliant with ISO9001-2008.
HP-G Series are primarily designed to meet requirements for the following
applications :
• Oil & Gas offshore and Onshore
• Petrochemical
• Chemical
• Power and Substations
• Production process plants
• Offshore installations
• Pumping control centers
• Airport - avionics and airfields
• Railways and metro lines
• Hospitals and healthcare
• Security and alarm equipments
• Isolation transormer
• Rectifier 6 to 12 pulses with thyristor
• IGBT Inverter configuration, PWM control
• Bridge IGBT interter
Options:
Customizable UPS
More autonomy on request
HP-G MODEL
POWER
INPUT
250
300
350
400
500
600
250
300
350
400
500
600
(kW)
200
240
280
320
400
480
VOLTAGE
380-400-415-440 VAC 3PH (3WIRE + G) 6 PULSE TYRISTOR RECTIFER (OPTION 12 PULSE)
(kVA)
50/60 HZ 10% SELECTABLE
FREQUENCY
0 85 LAGGING TYPICAL @100% LOAD 400VAC (0,91
0,85
(0 91 FOR 12 PULSE)
POWER FACTOR
380-400-415-440 VAC 3PH (3WIRE + G) WITH ISOLATION TRASFORMER
VOLTAGE
50/60Hz +/-0.01%
FREQUENCY
OUTPUT
125% FOR 10 MINUTES - 150% FOR 60 SECONDS
OVERLOAD
TRUE SINE WAVE (IGBT PWM CONTROLLED)
WAVE FORM
2% WITH 100% LINEAR LOAD - 5% WITH 80% NON LINEAR LOAD (IEC62040)
THD
92% AT 100% LOAD
EFFICIENCY
INPUT CONFIGURATION
BY-PASS
10% OF NOMINAL OUTPUT VOLTAGE (ADJUSTABLE)
TRANSFER LIMIT
OVERLOAD CAPABILITY
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE
192 (LEAD-ACID)
NUMBER
55
NOISE LEVEL
OPERATING TEMPERATURE
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
CONFIGURATION STANDARD
COMUNICATION
0-95% NON CONDENSING
STAND ALONE (OPTION PARALLEL CAPABILITY UP FOUR UNITS REDUNDANCY-CAPACITY)
2060x1060x2000 2860x1060x2000 2860x1060x2000 3860x1060x2000 4060x1060x2000 4060x1060x2000
1X RS232 - E.P.O. - ALLARM CONTACT (VOLTAGE FREE) - EXTERNAL AUX CONTACT FOR THE BY-PASS SWITCH
UL1778,IEC62040,ISO9001,EN52001
STANDARDS
IP20 INDOOR (OPTION IP OUTDOOR)
PROTECTIONS MECHANICAL
OPTIC
LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER OPTIONAL GRAPHICAL PANEL-TOUCH PANEL
ACOUSTIC
COMMON WITH RECTIFIED (DEFAULT) OR DUAL INPUT
BATTERY EXTENSION
OTHERS
32F-104F (0°C - 40°C)
REDUNDANT FANS - AIR FORCED
COOLING SYSTEM
DIMENSIONS UPS (WxDxH) mm
SIGNALLING
110% CONTINUOUS
INTERNAL MAINTENANCE BY-PASS
MANUAL
BATTERY
COMMON WITH RECTIFIED (DEFAULT) OR DUAL INPUT
TRANSFORMER ISOLATION
INVERTER BRIDGE
YES
YES
IGBT TECHNOLOGY
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
11 of 46
HP-G Series
FUNCTIONS AND FEATURES
The units provide a full insulation of the critical load from the mains in
order to ensure a full power availability and reliability over an heavy
polluted mains line supply , protecting the load from mains dip, sags and
heavy harmonic disturbance.
Units meets the L.U. specification NR_PS_ELP_0007_ISS_3.
Designed and manufactured in Italy since Y 2001 and the production
process is fully compliant with ISO9001-2008.
HP-G Series are primarily designed to meet requirements for the following
applications :
• Oil & Gas offshore and Onshore
• Petrochemical
• Chemical
• Power and Substations
• Production process plants
• Offshore installations
• Pumping control centers
• Airport - avionics and airfields
• Railways and metro lines
• Hospitals and healthcare
• Security and alarm equipments
• Isolation transormer
• Rectifier 6 to 12 pulses with thyristor
• IGBT Inverter configuration, PWM control
• Bridge IGBT inverter
Options:
Customizable UPS
More autonomy on request
HP-G MODEL
POWER
800
1000
(kVA)
800
1000
(kW)
640
800
380-400-415-440 VAC 3PH (3WIRE + G) 6 PULSE TYRISTOR RECTIFER (OPTION 12 PULSE)
VOLTAGE
INPUT
50/60 HZ 10% SELECTABLE
FREQUENCY
0,85 LAGGING TYPICAL @100% LOAD 400VAC (0,91 FOR 12 PULSE)
POWER FACTOR
380-400-415-440 VAC 3PH (3WIRE + G) WITH ISOLATION TRASFORMER
VOLTAGE
50/60Hz +/-0.01%
FREQUENCY
OUTPUT
125% FOR 10 MINUTES - 150% FOR 60 SECONDS
OVERLOAD
TRUE SINE WAVE (IGBT PWM CONTROLLED)
WAVE FORM
2% WITH 100% LINEAR LOAD - 5% WITH 80% NON LINEAR LOAD (IEC62040)
THD
92% AT 100% LOAD
EFFICIENCY
INPUT CONFIGURATION
BY-PASS
10% OF NOMINAL OUTPUT VOLTAGE (ADJUSTABLE)
TRANSFER LIMIT
OVERLOAD CAPABILITY
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE
192 (LEAD-ACID)
NUMBER
55
NOISE LEVEL
OPERATING TEMPERATURE
RELATIVE HUMIDITY ( @35°C )
CONFIGURATION STANDARD
DIMENSIONS UPS (WxDxH) mm
COMUNICATION
4860x1460x2000
FRONT ACCES REQUIRED FOR NORMAL MAINTENANCE
UL1778,IEC62040,ISO9001,EN52001
IP20 INDOOR (OPTION IP OUTDOOR)
PROTECTIONS MECHANICAL
LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER OPTIONAL GRAPHICAL PANEL-TOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
BATTERY EXTENSION
TRANSFORMER ISOLATION
INVERTER BRIDGE
STAND ALONE (OPTION PARALLEL CAPABILITY UP FOUR UNITS REDUNDANCY-CAPACITY)
1X RS232 - E.P.O. - ALLARM CONTACT (VOLTAGE FREE) - EXTERNAL AUX CONTACT FOR THE BY-PASS SWITCH
STANDARDS
OTHERS
0-95% NON CONDENSING
BOTTOM STANDARD-TOP OPTION
CONDUIT ACCES
INSTALLATON AND MAINTENANCE
SIGNALLING
32F-104F (0°C - 40°C)
REDUNDANT FANS - AIR FORCED
COOLING SYSTEM
GENERAL
NOTES
110% CONTINUOUS
INTERNAL MAINTENANCE BY-PASS
MANUAL
BATTERY
COMMON WITH RECTIFIED (DEFAULT) OR DUAL INPUT
YES
YES
IGBT TECHNOLOGY
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
12 of 46
HP-M
The modular online UPS series ENGINEERED IN ITALY, featured with DSP control, decentralized parallel structure, Modular N+X Parallel Redundancy, touch-screen LCD display,
Hot swappable, programmable battery voltage, 3-level intelligent charge modes with settable charge current, Megatec/Modbus protocol, is an ideal solution to your PC workstation,
server, bank, industriai equipment, Internet data center, telecom, IT equipments and other mission-critical application, which is demanding fora thorough protection.
FUNCTIONS AND FEATURES
Modular UPS On-line double conversion, with available power from 10
kVA to 300 kVA.
→ Decentralized Parallel Structure with Hot-swappable feature
→ Modular N+X Parallel Redundancy
→ DSP-controlled Technology
→ Unity lnput Power Factor with Low lnput Current Distortion
→ High Efficiency
→ ParaIlel up to Four Frames
→ Fit into standard 19" Rack Cabinet
→ Touch-screen LCD display for user's friendly operation
→ High Power Density per rack for space saving
→ lnvest as You Grow
→ Compact in size, only 3U height e Superior MTBF and MTTR
→ Emergency Power Off device can be operated on site or remotely
→ Common Battery
→ Programmable Battery Voltage 3-levellntelligent Charge Modes
with smart charge current adjustment
→ Megatec/Mod Bus protocol supported
→ Powerful charger built in Modular and UPS frame
→ Versatile communication interfaces provided for different
applications
→ Matching battery modular aIso available
HP‐M MODEL
POWER
UPS CABINET
HOT-SWAP MODULE
100
200
250
300
10~100kVA 9~90kW
10~200kVA 9~180kW
25~250kVA 22.5~225kW
30~300kVA 27~270kW
25kVA/22.5kW
30kVA/27kW
10kVA/9kW - 15kVA/13.5kW - 20kVA/18kW
MODULE
3 PHASE, 4 WIRES & GROUND
PHASE
230VAC AND
380/400/415VAC
VOLTAGE
380/400/415 VAC
208 ~ 478 VAC
VOLTAGE RANGE
40 ~ 70Hz
FREQUENCY
INPUT
≥0.99
POWER FACTOR
220V: +25%(OPTIONAL +10%、+15%、+20% )
230V: +20% (OPTIONAL +10%、+15%) 240V: +15%(OPTIONAL +10%)
MIN. VOLTAGE: -45% (OPTIONAL -20%、-30%) FREQUENCY PROTECTION RANGE: ±10%
BYPASS VOLTAGE RANGE
≤2% (100% NO LINEAR LOAD)
CURRENT HARMONIC
SUPPORT
GENERATOR INPUT
3 PHASE, 4 WIRES & GROUND
PHASE
380/400/415 VAC
VOLTAGE
0,9
POWER FACTOR
OUTPUT
±1%
VOLTAGE PRECISION
±1%、±2%、±4%、±5%、±10% OF THE RATED FREQUENCY (OPTIONAL)
FREQUENCY UTILITY MODE
(50/60±0.1)Hz
FREQUENCY BATTERY MODE
3:1
CREST FACTOR
≤2% W/ LINEAR LOAD - ≤5% WITH NON LINEAR LOAD
THD
EFFICIENCY
-
≥95.5% @ NORMAL MODE
INTERFACE
-
RS232, RS485, DRY CONTACT, INTELLIGENT SLOT x 2 (SNMP CARD, RELAY CARD OPTIONAL)
±192V\±204V\±216V\±228V\±240V DC; BATTERY QUANTITY (OPTIONAL)
VOLTAGE
CHARGE CURRENT UPS CABINET
BATTERY
CHARGE CURRENT HPM MODULE
60A MAX
100A MAX
10A MAX.
(CHARGE CURRENT CAN BE SET ACCORDING TO
INSTALLED BATTERY CAPACITY)
UTILITY TO BATTERY : 0ms; UTILITY TO BYPASS : 0ms
OVERLOAD AC MODE
PROTECTIONS
OVERLOAD BATTERY MODE
SINPEC_CT1501
60A MAX
6A MAX.
(CHARGE CURRENT CAN BE SET ACCORDING TO
INSTALLED BATTERY CAPACITY)
DEPENDS ON THE CAPACITY OF EXTERNAL BATTERIES
BACK UP TIME
TRANS. TIME
30A MAX
LOAD ≤110%: LAST 60min,≤125%: LAST 10min,≤150%: LAST 1min,
≥150% TURN TO BYPASS MODE IMMEDIATELY
LOAD ≤110%: LAST 10min,≤125%: LAST 1min,≤150%: LAST 10S,
≥150% SHUT DOWN UPS IMMEDIATELY
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
13 of 46
HP-M 10-300kVA
MODULAR MODEL
200
100
250
OPERATING
0 ~ 95% NOT CONDENSING
HUMIDITY
ENVIRONMENT STORAGE TEMPERATURE
-25°C ~ 55°C
< 1500m
ALTITUDE
600x840x1400
DIMENSIONS UPS CABINET (WxDxH)mm
OTHER
WEIGHT HPM MODULE
STANDARDS
600x1100x2000
443x580x131 mm(3U)
DIMENSIONS HPM MODULE (WxDxH)mm
WEIGHT UPS CABINET
300
0°C ~ 40°C
TEMPERATURE
170 Kg
270 Kg
10KVA: 26KG; 15KVA: 30KG; 20KVA:31KG
275 Kg
280 Kg
25KVA:31KG
30KVA:31KG
CE,EN/IEC 62040-2,EN/IEC 62040-1-1
-
EXTERNAL VIEW
MODULE
APPLICATIONS :
MEDICAL CENTERS, TECHNICAL AND ADMINISTRATIVE OFFICES, LABORATORIES, BANKS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
14 of 46
STATIC TRANSFER SWITCH
FUNCTIONS AND FEATURES
STS (Static Transfer Switch) between two sources of energy
technology "break before make" without interruption.
Available in single-phase, three-phase + N 3 and 4 poles.
Equipped with sectioning and manual bypass for both lines,
display showing electrical measurements, communication interface
RS232 / RS485 / SNMP/ MODBUS, Teleglobal Service (TGS).
SINGLE PHASE STS RANGE :
110(127)Vac / 220 (208-230-240)Vac 265 (277)Vac
16A 1P SIZE 2U RACK 19"
32A 1P SIZE 2U RACK 19"
50A 1P SIZE 3U RACK 19"
63A 1P SIZE 3U RACK 19"
16A 2P SIZE 3U RACK 19"
32A 2P SIZE 3U RACK 19"
50A 2P SIZE 3U RACK 19"
63A 2P SIZE 3U RACK 19"
STS MODEL
NOM. CURRENT (A)
FROM 63A AT MORE POWER AT REQUEST
100
200
300
400
600
800
1200
1600
100
200
300
400
600
800
1200
1600
380-400-415 VAC 3 PH+N
INPUT VOLTAGE
180-264 VAC (PH-N)
INPUT VOLTAGE TOLERANCE
50 - 60 Hz ±5%
INPUT FREQUENCY
> 90% FULL LOAD
EFFICIENCY
< 10%
ELECTRICAL DATA
INPUT VOLTAGE THD
TRANSFER MODE
"BREAK BEFORE MAKE"
SWITCHING TYPE
3 PHASE + NEUTRAL SWITCHING (4-POLES)
3:1
OUTPUT CREST FACTOR
0%- 100% CONTINUOUS
101%- 150% 1 min
ADMISSIBLE OVERLOAD
151%-200% 10 s
>200% 1 s
OUTPUT OVERLOAD & SHORT CIRCUIT PROTECTION, BACKFEED PROTECTION, SCR FAULT
PROTECTION
PROTECTION
LED STD.
PANEL & MIMIC
RS232 - RS485 - fREE CONTACTS PORT - MODBUS- TELEGLOBAL SERVICE-SNMP
REMOTE SIGNALLING
FIXED PRIORITY / NO PRIORITY (CAN BE SELECTED)
ENVIRONMENTAL DATA
RUNNING MODE
FORCED AIR (REDUNDANT FANS)
COOLING SYSTEM
FROM 0°C TO 40°C
OPERATING TEMPERATURE
-10°C / +50°C
STORAGE TEMPERATURE
<90% NOT CONDENSING
HUMIDITY
PROTECTION
IP20
STANDARDS
CE IEC EN60950, EN62310- 1/2/3, EN 61000-6-2, EN 61000-6-4, EMC , EN 60947-3 , ISO
DIMENSIONS UPS (WxDxH) mm
660x680
x1400
860x860
x1800
860x860
x1800
860x860
x1800
1060x660
x1800
1860x860
x1800
2060x860
x1800
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
15 of 46
FC AVIO 400Hz
FUNCTIONS AND FEATURES
Frequency Converter a new IGBT -PWM solid state hi-efficiency integrated
system converter for top class performances on 400Hz ground power
supply .
The units are also available on multiple output system range and different
standard size - Custom size are also available on request
Wide input power supply range available from 380 VAC to 480 VAC 3Ph +
G.
Multiple output configuration 200/115V 400Hz 3Ph+ N + G ( adjustable +10% ) 36V 400Hz 1Ph + N + G and 28VDC (configuration available from
50A up to 600 A)
Standard bottom cable entry – degree of protection IP21 –Color RAL 7035
EN 61000-6-2, EN 61000-6-4, 2006/95/EC, ISO 1540, ISO 6858, SAE
ARP 5015, MIL-STD-704F, MIL-STD-1472, DFS-400MIL, STD-405-F
compliant
Options:
→ 12 pulse input rectifier for lower THD current level
→5th and 7th harmonic input filter on request on 6 pulse units
→Trailer available ( certified ) on request to allow easy handling of the unit
up to 150kva
→Top cable entry on request for standalone units
→ Increased degree of protection from IP31 to IP52
→ Full range of customized colors available
→ Voltage drop compensation available
→ ± 10% output voltage adj potentiometer available on request
→ size and weight depends upon the configuration,
FC AVIO MODEL
POWER (kVA)
Floor mounted version (FC-F)
20
30
50
60
100
120
20
30
50
60
100
120
92%
92%
STAND ALONE
CONFIGURATION STANDARD
GENERAL
DATA
OVERALL Ac/Ac EFFICIENCY 100% LOAD
91%
91%
91%
88%
89%
90%
90%
90%
91%
HEAT REJECTION AT 100% LOAD 0,8PF
5 598 95
5.598,95
8 199 73
8.199,73
13 336 52
13.336,52
20 290 31
20.290,31
24 712 10
24.712,10
29 650 05
29.650,05
25
25
25
25
25
25
CONFIGURATION
6 PULSE TYRISTOR RECTIFIER - 12 PULSE ON REQUEST
INPUT VOLTAGE
380-400-415-440-480 Vac 3PH - 3 WIRE + GROUND (+/-15%)
50/60Hz (+/- 10%) SELECTABLE
INPUT FREQUENCY
0,9 LAGGING TYPICAL @ 100% LOAD @ 400Vac - 0,92 LAGGING ON 12 PULSE
POWER FACTOR
LIMITED BY SOFT-START CIRCUIT
INRUSH CURRENT
IGBT PWM CONTROLLED
CONFIGURATION
190-200 V ac 400Hz - 3PH, 4WIRE + GROUND (ADJ +/-10%)
NOMINAL OUTPUT VOLTAGE
INVERTER
36 V ac 1PH, 2 WIRE + GROUND MAX 20% UNIT SIZE
NOMINAL OUTPUT VOLTAGE (OPT 1)
NOMINAL OUTPUT VOLTAGE (OPT 2)
28 V dc 2 WIRE GROUND UP TO 600A
INVERTER BRIDGE AND WAVEFORM
IGBT TECHNOLOGY - TRUE SINE WAVE
YES - WITH TRASFORMER ISOLATION
OUTPUT ISOLATION
(+/-) 1%
STATIC
INVERTER
SPECS
LOAD STEP 0% - 100% - 0%
(+/-) 8% RECOVERING WITHIN TOLERANCE INTO 2 CYCLES
LOAD STEP 0% - 50% - 0%
(+/-) 3% RECOVERING WITHIN TOLERANCE INTO 2 CYCLES
3% VOLTAGE DEVIATION
100% UNBALANCED LOAD (IEC62040)
2% THD MAXIMUN (5% AT 80% NON LINEAR LOAD - IEC62040)
100% LINEAR LOAD
OUTPUT
VOLTAGE
DISTORTION
3:1 WITH 80% LOAD
CREST FACTOR COMPATIBILITY
200%
OUTPUT NEUTRAL WIRE RATING
100% BALANCED LOAD 120° +/-1% - 100% UNBALANCED LOAD (80%-0-80%) 120° +/-2%
PH DISPLACEMENT
OUTPUT
FREQUENCY
400Hz, +/-0,01%
FREE RUNNING
125% AT 0,8PF FOR 10 MINUTES / 150% AT 0,8PF FOR 60 SECONDS
OVERLOAD CAPABILITY (ON INVERTER)
MAX OP CURRENT @ 0,8PF 3PH 200Vac
53A
79A
262A
334A
FORCED AIR (REDUNDANT FANS)
ENCLOSURE COOLING
FROM 0°C TO 40°C
OPERATING TEMPERATURE
WEIGHT AVERAGE (Kg)
174A
EMERGENCY POWER OFF - ALARM CONTACT -1X RS232-
GENERAL
SIZE (mm)
132A
UL1778, IEC62040, ISO9001,EN52001- MIL- STD-405_F AND OTHERS
STANDARD
GENERAL
92%
OVERALL Ac/Ac EFFICIENCY 50% LOAD
FAULT CORRENT RATING (KVA)
RECTIFER
Movable version (FC-M)
800x750x1200
800x750x1200
860x860x2000
860x860x2000
1060x860x2000
1060x860x2000
300
380
470
610
700
900
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
16 of 46
Z NO-BREAK
FUNCTIONS AND FEATURES
AC UPS SYSTEM
→ Inverter high frequency PWM
→ Single-phase input
→ Single-phase sinusoidal output
→ Isolating transformer in the inverter output
→ Efficiency DC / AC high
→ Microprocessor control with Self- Diagnostics
→ LCD Display for information on the state
→ Battery test manual and automatic (emergency version)
→ Response time less than 0.5 sec
→ Operation in rescue or emergency (SA/SE) selectable
→ External battery - Nominal Voltage 48Vdc (SELV)
→ Auto- off Timer Weekly
→ Operation in rescue or emergency
→ Can be connected to any load normally intended for safety
→ Suitable for any type of load ( pumps, motors , lights, lamps
also
power factor corrected , small refrigerators, air conditioners )
→ Compact size and reduced, Easy wall mounting
Options:
→ Communication interface (RS232 and contacts) and software
for
control and management
→ ADAPTER SNMP and related software
→ Communication board alarm relay
→ Contact for emergency button (EPO ) to stop inverter
immediate
→ Mimic panel remote
→ External command to output enable
→ Switching for two pumps
→ Battery life expectancy 10 years (EN 50171 )
Z NO‐BREAK MODEL
POWER (Watt)
INPUT
1000
1500
2000
2500
3000
1000
1500
2000
2500
3000
230VAC ± 20%
VOLTAGE
50Hz ± 5% (OPTIONAL 60Hz)
FREQUENCY
230 VAC ± 0,5% (BATTERY MODE)
VOLTAGE
50Hz ± 5% (OPTIONAL 60Hz)
FREQUENCY
110% FOR 60sec - 130% 10sec - LOAD DISCONNECT & ALARM
OVERLOAD
OUTPUT
SINEWAVE
WAVE FORM
< 3% (LINEAR LOAD)
THD
BATTERY MODE >91% - LINE MODE >98%
EFFICIENCY
1h
STD. BACK UP
6 - 10h
RECHARGE TIME
< 40 dBA (@ 1 m)
NOISE LEVEL
FROM 0°C TO 40°C
OPERATING TEMPERATURE
GENERAL
NOTES
315x245x537
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
PROTECTIONS
<90% NOT CONDENSING
RELATIVE HUMIDITY ( @35°C )
44
50
50
56
56
STANDARDS
EN 62040-1-2, EMC EN 62040-2, CSS EN 50171
ELECTRONIC
OVERLOAD - SHORTCIRCUIT - BATTERY LOW - FUSE IN-OUT & BATTERY
MECHANICAL
IP21
SIZING
To properly size the equipment is necessary to evaluate the power of the loads (sum of the devices), cosϕ, yield and starting load.
Following indicative table:
Z NO‐BREAK MODEL
POWER (Watt)
Q.TY PIPES 6-8W (cosϕ 0,8)
Q.TY PIPES 18-20W (cosϕ 0,8)
Q.TY PIPES 36-40W (cosϕ >0,9)
Q.TY PIPES 58-65W (cosϕ >0,9)
INCANDESCENT LIGHTS
ELECTRONIC LIGHTS W/ PFC (cosϕ >0,9)
AUTONOMY (FROM - AT)
1000
1000
75
37
20
12
1000W
800W
1500
1500
112
56
32
18
1500W
1200W
1 HR to 2 HRS
2000
2000
150
75
45
25
2000W
1600W
2500
2500
188
94
55
31
2500W
2000W
3000
3000
225
112
65
37
3000W
2400W
1 HR
APPLICATIONS :
INDUSTRIAL/DOMESTIC USES TO PREVENT BLACKOUTS, ANTI‐FLOODING PUMPS, REFRIGERATORS, MOTORS, etc. SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
17 of 46
SS NO-BREAK
FUNCTIONS AND FEATURES
→ Inverter IGBT high frequency
→ Single-phase input
→ Single-phase sine wave output
→ Isolating transformer in the inverter output
→ Efficiency DC / AC high
→ PFC circuit input
→ Microprocessor control with Self- Diagnostics
→ LCD Display for information on the state of the Rescuer
→ Battery test manual and automatic(emergency version)
→ Switching time less than 200 ms
→ Operation in rescue or emergency ( SA / SE ) selectable
→ Auto- off Timer Weekly
→Can be connected to any load or for safety
→ Particularly suitable for lighting lamps with power factor correction
Options:
→"ECO Mode"
→ Three-phase input
→ Communication interface ( RS232 and contacts) and Control
Software and Management
→ SNMP adapter and related software
→ Communication board alarm relay
→ Contact for emergency button (EPO ) to stop inverter immediate
→ Goodwill works even without network
→ Ability dual output SA + SE
→ Mimic panel remote
→ Battery life expectancy 10 years (EN 50171 )
MODEL "R" : Free acid batteries with low maintenance ( No shipping by air or sea )
MODEL "E" : AGM VRLA sealed batteries maintenance free ( Stationary )
SS NO-BREAK MODEL
POWER (Watt)
INPUT
VOLTAGE
FREQUENCY
VOLTAGE
FREQUENCY
OVERLOAD
WAVE FORM
OUTPUT
THD
EFFICIENCY
STD. BACK UP
RECHARGE TIME
NOISE LEVEL
OPERATING TEMPERATURE
GENERAL
RELATIVE HUMIDITY ( @35°C )
NOTES
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
STANDARDS
ELECTRONIC
PROTECTIONS MECHANICAL
AUTONOMY (FROM - TO)
1000
1000
60
2000
2000
3000
3000
4000
5000
7500
4000
5000
7500
230VAC ± 20%
50Hz ± 5% (OPTIONAL 60Hz)
230 VAC ± 0,5% (BATTERY MODE)
50Hz ± 5% (OPTIONAL 60Hz)
110% FOR 60sec - 130% 10sec
SINEWAVE
< 3% (LINEAR LOAD)
BATTERY MODE >91% - LINE MODE >98%
FROM 1h to 3h
6h - 10h
< 40 dBA (@ 1 m)
FROM 0°C TO 40°C
<90% NOT CONDENSING
805x600x905
60
64
72
80
98
EN 62040-1-2, EMC EN 62040-2, CSS EN 50171
OVERLOAD - SHORTCIRCUIT - BATTERY LOW - FUSE IN-OUT & BATTERY
IP21
1HR to 3HRS
1HR to 2HRS
10000
10000
110
1HR
SIZING
To properly size the equipment is necessary to evaluate the power of the loads (sum of the devices), cosϕ, yield and starting load.
Following indicative table:
SS NO-BREAK MODEL
POWER (Watt)
Q.TY PIPES 6-8W (cosϕ 0,8)
Q.TY PIPES 18-20W (cosϕ 0,8)
Q.TY PIPES 36-40W (cosϕ >0,9)
Q.TY PIPES 58-65W (cosϕ >0,9)
INCANDESCENT LIGHTS
ELECTRONIC LIGHTS W/ PFC (cosϕ >0,9)
1000
1000
75
37
20
12
1000W
800W
2000
2000
150
75
45
25
2000W
1600W
3000
3000
225
112
65
37
3000W
3200W
4000
4000
300
150
85
55
4000W
2400W
5000
5000
375
187
105
65
5000W
4000W
7500
7500
562
281
150
95
7500W
6000W
10000
10000
750
375
200
125
10000W
8000W
APPLICATIONS :
INDUSTRIAL/DOMESTIC USES TO PREVENT BLACKOUTS, ANTI-FLOODING PUMPS, REFRIGERATORS, MOTORS, etc.
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
18 of 46
RES DC
FUNCTIONS AND FEATURES
These devices are the result of an action research and
development undertaken by our company, targeted for maximum
reliability and performance in the field of emergency power
systems DC especially for all applications of these ancillary
services transformation. No booths in case it has chosen to
implement the section of energy conversion in traditional
technology (isolating transformer with a thyristor bridge ), plus
the added flexibility to the forefront of the digital logic with a micro
controller.
Standard autonomy 30' 60' 120'. (More autonomy on request)
LCD PANEL STANDARD
Options:
→ Float / Boost / Manual charge
→ Internal / External temperature compensation
→ External potenziometer for voltage setpoint
→ Measurement of current recharge battery on LCD display
→ Manual / Automatic battery charge
230 / 400 ± 10% 2 WIRES
INPUT VOLTAGE (VAC)
INPUT CURRENT DISTORTION
INPUT POWER FACTOR
OUTPUT NOMINAL VOLTAGE
ELECTRICAL DATA
≥ 0.8
( @ NOMINAL INPUT VOLTAGE,
100% LOAD )
24 ÷ 48 ÷ 110 (VDC)
5 ÷ 50 * 24VDC 48VDC 110VDC
2.27 V/CELL FOR
VRLA BATTERY TYPE¹
2,2 ÷ 2,3V/CELL FOR
FLOATING
VLA BATTERY TYPE¹
1,4 ÷ 1,5V/CELL FOR Ni-Cd
BATTERY TYPE¹
2,4 ÷ 2,45V/CELL FOR
RAPIDA BOOST
VLA BATTERY TYPE¹
(OPTIONAL)
1,5 ÷ 1,65V/CELL FOR
Ni-Cd BATTERY TYPE¹
2.35V/CELL FOR
VRLA BATTERY TYPE¹
2,7V/CELL FOR
EXTERNAL POTENTIOMETER
VLA BATTERY TYPE¹
(OPTIONAL)
1,7V/CELL FOR
Ni-Cd BATTERY TYPE¹
(¹) (ADJUSTABLE W/TRIMMER)
1%
OUTPUT VOLTAGE STABILITY (@ NOMINAL IMPUT VOLTAGE,
100% LOAD)
2% RMS (OTHER ON REQUEST)
OUTPUT RIPPLE
<120% for 20 min.
<150% for 1 min.
OVERLOAD
>150% for 10 sec.
( W/O BATTERY)
IU-DIN 41773 - STANDARD
I1 I2 U - OPTION
BATTERY RECHARGE SYSTEM
MANUAL - OPTION
THERMAL COMPENSATION OPTION
OUTPUT URRENT (Amp)
SINPEC_CT1501
≤ 40
@ NOMINAL LOAD (THD%)
ACOUSTIC NOISE LEVEL
<65 dBA (ACCORDING
EN50091)
W/ FORCED VENTILATION
EMI
EN 61000-6-2 EN 61000-6-4
OPERATING TEMP. (°C)
-10°C ÷ +40°C
STORAGE TEMP. (°C)
-12°C ÷ +70°C
RELATIVE HUMIDITY
< 95% NOT CONDENSING
VENTILATION
ALTITUDE (m.a.s.l.)
PROTECTION DEGREE
COLOR
MECHANICAL DATA
≤ 15KA Rms
( @ VAC NOMINAL, IEC STD.)
INPUT SHORT CIRCUIT
CURRENT
ENVIRONMENTAL DATA
50 - 60Hz ± 5%
INPUT FREQUENCY
FORCED - NATURAL
(DEPENDING FROM POWER)
<2000 (DE-RATING EN62040-3)
IP20 ( REF. IEC 60529 )
RAL 7035 - STANDARD
550x520x420
DIMENSIONS (WxDxH) mm
550x520x750
600x600x1600
IN/OUT
I/O CABLES CONNECTION
ACCESSIBILITY
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
FRONT - REAR
FRONT - TOP
19 of 46
RES DC
SINGLE LINE DIAGRAM - STANDARD
STANDARD MEASURES
Vout : Output Voltage
Iout : Output Current
Pout : Output Power
AC OFF: Number Mains
Power Failure
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
20 of 46
LCD
FUNCTIONS AND FEATURES
LCD SINGLE BRANCH RECTIFIER
These devices are the result of an action research and development
undertaken by our company, targeted for maximum reliability and
performance in the field of emergency power systems DC especially
for all applications of these ancillary services transformation. No
booths in case it has chosen to implement the section of energy
conversion in traditional technology (isolating transformer with a
thyristor bridge ), plus the added flexibility to the forefront of the
digital logic with a micro controller.
Standard autonomy 30' 60' 120'. (More autonomy on request)
Options:
→ Float / Boost / Manual charge
→ Internal / External temperature compensation
→ External potenziometer for voltage setpoint
→ Measurement of current recharge battery on LCD display
→ Manual / Automatic battery charge
400 ± 10% 3 WIRES
INPUT VOLTAGE (VAC)
INPUT CURRENT DISTORTION
INPUT POWER FACTOR
OUTPUT NOMINAL VOLTAGE
OUTPUT URRENT (Amp)
ELECTRICAL DATA
FLOATING
RAPIDA BOOST
(OPTIONAL)
EXTERNAL POTENTIOMETER
(OPTIONAL)
OUTPUT RIPPLE
OVERLOAD
BATTERY RECHARGE
SYSTEM
SINPEC_CT1501
≤ 15KA Rms
( @ VAC NOMINAL, IEC STD.)
≤ 27
@ NOMINAL LOAD (THD%)
≥ 0.8
( @ NOMINAL INPUT VOLTAGE,
100% LOAD )
24 ÷ 48 ÷ 110 (VDC)
5 ÷ 250 * 24VDC 48VDC 110VDC
2.27 V/CELL FOR
VRLA BATTERY TYPE¹
2,2 ÷ 2,3V/CELL FOR
VLA BATTERY TYPE¹
1,4 ÷ 1,5V/CELL FOR Ni-Cd
BATTERY TYPE¹
2,4 ÷ 2,45V/CELL FOR
VLA BATTERY TYPE¹
1,5 ÷ 1,65V/CELL FOR
Ni-Cd BATTERY TYPE¹
2.35V/CELL FOR
VRLA BATTERY TYPE¹
2,7V/CELL FOR
VLA BATTERY TYPE¹
1,7V/CELL FOR
Ni-Cd BATTERY TYPE¹
(¹) (ADJUSTABLE W/TRIMMER)
1%
(@ NOMINAL IMPUT VOLTAGE,
100% LOAD)
1% RMS (OTHER ON REQUEST)
<120% for 20 min.
<150% for 1 min.
>150% for 10 sec.
( W/O BATTERY)
IU-DIN 41773 - STANDARD
I1 I2 U - OPTION
MANUAL - OPTION
THERMAL COMPENSATION OPTION
ACOUSTIC NOISE LEVEL
<65 dBA (ACCORDING
EN50091)
W/ FORCED VENTILATION
EMI
EN 61000-6-2 EN 61000-6-4
OPERATING
TEMP. (°C)
-10°C ÷ +40°C
STORAGE TEMP. (°C)
-12°C ÷ +70°C
RELATIVE HUMIDITY
< 95% NOT CONDENSING
VENTILATION
ALTITUDE (m.a.s.l.)
PROTECTION DEGREE
COLOR
MECHANICAL DATA
INPUT SHORT CIRCUIT CURRENT
ENVIRONMENTAL DATA
50 - 60Hz ± 5%
INPUT FREQUENCY
OUTPUT VOLTAGE
STABILITY
LCD PANEL STANDARD
FORCED - NATURAL
(DEPENDING FROM POWER)
<2000 (DE-RATING
EN62040-3)
IP20 ( REF. IEC 60529 )
RAL 7035 - STANDARD
DIMENSIONS
(WxDxH) mm
600x800x1000
800x800x1900
600x800x1500
1400x800x1900
IN/OUT
I/O CABLES
CONNECTION
FRONT - REAR
ACCESSIBILITY
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
FRONT - TOP
21 of 46
LCD
SINGLE LINE DIAGRAM - STANDARD
STANDARD MEASURES
Vout : Output Voltage
Iout : Output Current
Pout : Output Power
AC OFF: Number Mains
Power Failure
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
22 of 46
PLATINUM S
FUNCTIONS AND FEATURES
PLATINUM S SINGLE BRANCH RECTIFIER
These devices are the result of an action research and
development undertaken by our company, targeted for
maximum reliability and performance in the field of emergency
power systems DC especially for all applications of these
ancillary services transformation. No booths in case it has
chosen to implement the section of energy conversion in
traditional technology (isolating transformer with a thyristor
bridge ), plus the added flexibility to the forefront of the digital
logic with a micro controller.
Standard autonomy 30' 60' 120'. (More autonomy on request)
COMMUNICATION MODBUS PROTOCOL : RS232
MACHINE INTERFACE 3,5", COLOR TOUCH SCREEN
HOME PAGE
multi-color leds and
menu navigation buttons on
each page for easy use
Options:
→ Float / Boost / Manual charge
→ Internal / External temperature compensation
→ External potenziometer for voltage setpoint
→ Manual / Automatic battery test
→ Sensor ground pole
→ RS485
→ TCP/IP
MEASURE PAGE
Numeric display and
bar graphic
ALARMS & COUNT EVENT PAGE
You can see the last 100 alarms and how many
times have taken place
400 ± 10% 3 WIRES
≤ 15KA Rms
( @ VAC NOMINAL, IEC STD.)
≤ 27
@ NOMINAL LOAD (THD%)
≥ 0.8
INPUT POWER FACTOR
( @ NOMINAL INPUT VOLTAGE,
100% LOAD )
24 ÷ 48 ÷ 110 ÷ 220 (VDC)
OUTPUT NOMINAL VOLTAGE
INPUT SHORT CIRCUIT
CURRENT
INPUT CURRENT
DISTORTION
5 ÷ 250 * 24VDC 48VDC
OUTPUT URRENT (Amp)
ELECTRICAL DATA
FLOATING
RAPIDA BOOST
(OPTIONAL)
EXTERNAL
POTENTIOMETER
(OPTIONAL)
OUTPUT VOLTAGE
STABILITY
OUTPUT RIPPLE
ACOUSTIC NOISE LEVEL
50 - 60Hz ± 5%
5 ÷ 200 * 110VDC
5 ÷ 100 * 220VDC
2.27 V/CELL FOR
VRLA BATTERY TYPE¹
2,2 ÷ 2,3V/CELL FOR
VLA BATTERY TYPE¹
1,4 ÷ 1,5V/CELL FOR Ni-Cd
BATTERY TYPE¹
2,4 ÷ 2,45V/CELL FOR
VLA BATTERY TYPE¹
1,5 ÷ 1,65V/CELL FOR
Ni-Cd BATTERY TYPE¹
2.35V/CELL FOR
VRLA BATTERY TYPE¹
2,7V/CELL FOR
VLA BATTERY TYPE¹
1,7V/CELL FOR
Ni-Cd BATTERY TYPE¹
(¹) (ADJUSTABLE W/TRIMMER)
1%
(@ NOMINAL IMPUT VOLTAGE,
100% LOAD)
1% RMS (OTHER ON REQUEST)
ENVIRONMEN
NTAL DATA
INPUT FREQUENCY
EMI
<65 dBA (ACCORDING EN50091)
W/ FORCED VENTILATION
EN 61000-6-2 EN 61000-6-4
OPERATING TEMP. (°C)
-10°C ÷ +40°C
STORAGE TEMP. (°C)
-12°C ÷ +70°C
RELATIVE HUMIDITY
< 95% NOT CONDENSING
VENTILATION
ALTITUDE (m.a.s.l.)
PROTECTION DEGREE
COLOR
MECHANICAL DATA
INPUT VOLTAGE (VAC)
FORCED - NATURAL
(DEPENDING FROM POWER)
<2000 (DE-RATING
EN62040-3)
IP20 ( REF. IEC 60529 )
RAL 7035 - STANDARD
600x600x1600
DIMENSIONS
(WxDxH) mm
600x600x1940
800x800x1940
IN/OUT
I/O CABLES CONNECTION
ACCESSIBILITY
FRONT
FRONT - TOP
<120% for 20 min.
<150% for 1 min.
OVERLOAD
>150% for 10 sec.
( W/O BATTERY)
IU-DIN 41773 - STANDARD
I1 I2 U - OPTION
BATTERY RECHARGE SYSTE
MANUAL - OPTION
THERMAL COMPENSATION OPTION
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
23 of 46
PLATINUM S
WHAT TO SEND IN MODBUS
Output oltage - Output Current - Ouput power - Current recharge batteries Rate of current used - Rate Autonomy remaining General condition of the system
( Mains fault ÷ Rectifier stop ÷ Battery mode ÷ Limit autonomy ÷ End Autonomy ÷ Fault batteries ÷ Pole ground ÷ Overload ÷ VDC out max ÷ VDC out min ÷ Float ÷
SINGLE LINE DIAGRAM - STANDARD
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
24 of 46
PLATINUM D
FUNCTIONS AND FEATURES
PLATINUM D DOUBLE BRANCH RECTIFIER
These devices are the result of an action research and
development undertaken by our company, targeted for
maximum reliability and performance in the field of emergency
power systems DC especially for all applications of these
ancillary services trasformation . No booths in case it has
chosen to implement the section of energy conversion in
traditional technology (isolating transformer with a thyristor
bridge), plus the added flexibility to the forefront of the digital
logic with a micro controller.The system consist of two
independent sections defined in SERVICE BRANCH (RS) and
BATTERY CHARGER BRANCH (RCB). COMMUNICATION
MODBUS PROTOCOL : RS232
Standard autonomy 30' 60' 120'. (More autonomy on request)
There are two possible configurations:
→ BASE : In case of failure of the RS branch, the branch
RCB can power the load to maintain voltage and current
limit set at request. In case of failure of the branch RCB
the branch RS can not recharge batteries
→ ADVACED : A failure in one of two branches, the
remaining completely replace the power failure is how the
utilities and as battery charging. With this type of system is
in effect creates a configuration of "REDUNDANCY" in
order to increase system reliability and ensuring a high
degree of safety to the load.
MACHINE INTERFACE 3,5", COLOR TOUCH SCREEN
HOME PAGE
multi-color leds and
menu navigation buttons on
each page for easy use
ALARMS & COUNT EVENT PAGE
You can see the last 100 alarms and how many
times have taken place
Options:
→ Float / Boost / Manual charge
→ External potenziometer for voltage setpoint
→ Manual charge
→ RS485
400 ± 10% 3 WIRES
(OTHER ON REQUEST)
50 - 60Hz ± 5%
≤ 15KA R
Rms
( @ VAC NOMINAL, IEC STD.)
INPUT SHORT CIRCUIT
CURRENT
≤ 40 ( 1Ph ) ≤ 27 ( 3Ph )
@ NOMINAL LOAD (THD%)
≥ 0.7 ( 1Ph ) ≥ 0.8 ( 3Ph )
INPUT POWER FACTOR
( @ NOMINAL INPUT VOLTAGE,
100% LOAD )
24 ÷ 48 ÷ 110 ÷ 220 (VDC)
OUTPUT NOMINAL VOLTAGE
INPUT CURRENT
DISTORTION
5 ÷ 250 * 24VDC 48VDC
OUTPUT URRENT (Amp)
ELECTRICAL DATA
FLOATING
RAPIDA BOOST
(OPTIONAL)
EXTERNAL
POTENTIOMETER
(OPTIONAL)
OUTPUT VOLTAGE
STABILITY
OUTPUT RIPPLE
OVERLOAD
BATTERY RECHARGE
SYSTEM
SINPEC_CT1501
5 ÷ 200 * 110VDC
5 ÷ 100 * 220VDC
2.27 V/CELL FOR
VRLA BATTERY TYPE¹
2,2 ÷ 2,3V/CELL FOR
VLA BATTERY TYPE¹
1,4 ÷ 1,5V/CELL FOR Ni-Cd
BATTERY TYPE¹
2,4 ÷ 2,45V/CELL FOR
VLA BATTERY TYPE¹
1,5 ÷ 1,65V/CELL FOR
Ni-Cd BATTERY TYPE¹
2.35V/CELL FOR
VRLA BATTERY TYPE¹
2,7V/CELL FOR
VLA BATTERY TYPE¹
1,7V/CELL FOR
Ni-Cd BATTERY TYPE¹
(¹) (ADJUSTABLE W/TRIMMER)
1%
(@ NOMINAL IMPUT VOLTAGE,
100% LOAD)
2%.( 1Ph ) 1% ( 3Ph)
(OTHER ON REQUEST)
<120% for 20 min.
<150% for 1 min.
>150% for 10 sec.
( W/O BATTERY)
IU-DIN 41773 - STANDARD
I1 I2 U - OPTION
MANUAL - OPTION
THERMAL COMPENSATION OPTION
ENVIRONMENTAL DATA
INPUT FREQUENCY
→ Internal / External temperature
compensation
→ Manual / Automatic battery test
→ Sensor ground pole
→ TCP/IP
ACOUSTIC NOISE LEVEL
EMI
<65 dBA (ACCORDING EN50091)
W/ FORCED VENTILATION
EN 61000-6-2 EN 61000-6-4
OPERATING TEMP. (°C)
-10°C ÷ +40°C
STORAGE TEMP. (°C)
-12°C ÷ +70°C
RELATIVE HUMIDITY
< 95% NOT CONDENSING
VENTILATION
ALTITUDE (m.a.s.l.)
PROTECTION DEGREE
COLOR
MECHANICAL DATA
INPUT VOLTAGE (VAC)
MEASURE PAGE
Numeric display and
bar graphic
FORCED - NATURAL
(DEPENDING FROM POWER)
<2000 (DE-RATING EN62040-3)
IP20 ( REF. IEC 60529 )
RAL 7035 - STANDARD
600x600x1600
DIMENSIONS (WxDxH) mm
600x600x1940
800x800x1940
IN/OUT
I/O CABLES CONNECTION
ACCESSIBILITY
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
FRONT
FRONT - TOP
25 of 46
PLATINUM D
WHAT TO SEND IN MODBUS
RS Output voltage - RS Output Current - RCB Output voltage - RCB Output Current - Output power - Rate of current used - Rate Autonomy remaining
General conditio of the system ( Mains fault ÷ Rectifier stop ÷ Battery mode ÷ Limit autonomy ÷ End Autonomy ÷ Fault batteries ÷ Pole ground ÷ Overload ÷ VDC out
max RS ÷ VDC out min RS ÷ VDC out max RCB ÷ VDC out min RCB Float ÷ Boost ÷ Manual charge)
SINGLE LINE DIAGRAM - STANDARD
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
26 of 46
INDUSTRIA
FUNCTIONS AND FEATURES
INDUSTRIA DOUBLE BRANCH RECTIFIER
These devices are the result of an action research and
development undertaken by our company, targeted for
maximum reliability and performance in the field of emergency
power systems DC especially for all applications of these
ancillary services transformation. No booths in case it has
chosen to implement the section of energy conversion in
traditional technology (isolating transformer with a thyristor
bridge ), plus the added flexibility to the forefront of the digital
logic with a micro controller.
Standard autonomy 30' 60' 120'. (More autonomy on request)
FRONT PANEL
Options:
→ Float / Boost / Manual charge
→ Internal / External temperature compensation
→ External potenziometer for voltage setpoint, manual
battery charge
→DC probe ground
( STD. FOR 110 ÷ 220VDC OPTIONAL FOR 24 ÷ 48VDC)
230 ±10% 2 WIRES
400 ±10% 2 WIRES, 3 WIRES**
INPUT VOLTAGE (VAC)
≤ 15KA Rms
( @ VAC NOMINAL, IEC STD.)
INPUT SHORT CIRCUIT
CURRENT
≤ 40 ( 1Ph ) ≤ 27 ( 3Ph )
@ NOMINAL LOAD (THD%)
INPUT CURRENT
DISTORTION
INPUT POWER FACTOR
OUTPUT NOMINAL VOLTAGE
≥ 0.7 ( 1Ph ) ≥ 0.8 ( 3Ph )
( @ NOMINAL INPUT VOLTAGE,
100% LOAD )
24 ÷ 48 ÷ 110 (VDC)
5 ÷ 250 * 24VDC 48VDC
EMI
<65 dBA (ACCORDING EN50091)
W/ FORCED VENTILATION
EN 61000-6-2 EN 61000-6-4
OPERATING TEMP. (°C)
-10°C ÷ +40°C
STORAGE TEMP. (°C)
-12°C ÷ +70°C
RELATIVE HUMIDITY
< 95% NOT CONDENSING
VENTILATION
ALTITUDE (m.a.s.l.)
PROTECTION DEGREE
COLOR
MECHANICAL DATA
ELECTRICAL DATA
SINPEC_CT1501
5 ÷ 200 * 110VDC
5 ÷ 100 * 220VDC **
2.27 V/CELL FOR
VRLA BATTERY TYPE¹
2,2 ÷ 2,3V/CELL FOR
FLOATING
VLA BATTERY TYPE¹
1,4 ÷ 1,5V/CELL FOR Ni-Cd
BATTERY TYPE¹
2,4 ÷ 2,45V/CELL FOR
RAPIDA BOOST
VLA BATTERY TYPE¹
(OPTIONAL)
1,5 ÷ 1,65V/CELL FOR
Ni-Cd BATTERY TYPE¹
2.35V/CELL FOR
VRLA BATTERY TYPE¹
2,7V/CELL FOR
EXTERNAL POTENTIOMETER
VLA BATTERY TYPE¹
(OPTIONAL)
1,7V/CELL FOR
Ni-Cd BATTERY TYPE¹
(¹) (ADJUSTABLE W/TRIMMER)
1%
OUTPUT VOLTAGE STABILITY (@ NOMINAL IMPUT VOLTAGE,
100% LOAD)
2%.( 1Ph ) 1% ( 3Ph)
OUTPUT RIPPLE
(OTHER ON REQUEST)
<120% for 20 min.
<150% for 1 min.
OVERLOAD
>150% for 10 sec.
( W/O BATTERY)
BATTERY RECHARGE
SYSTEM
ENVIRONMENTAL DATA
50 - 60Hz ± 5%
INPUT FREQUENCY
OUTPUT URRENT (Amp)
ACOUSTIC NOISE LEVEL
FORCED - NATURAL
(DEPENDING FROM POWER)
<2000 (DE-RATING EN62040-3)
IP30 ( REF. IEC 60529 )
RAL 7035 - STANDARD
600x600x1600/1800²
DIMENSIONS (WxDxH) mm
800x600x1600/1800²
800x800x1800
(²)(DEPENDING FROM POWER)
IN/OUT
I/O CABLES CONNECTION
ACCESSIBILITY
FRONT
FRONT - TOP
IU-DIN 41773 - STANDARD
I1 I2 U - OPTION
MANUAL - OPTION
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
27 of 46
INDUSTRIA
SINGLE LINE DIAGRAM - STANDARD
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
28 of 46
CONSUMER SERIES
COMPACT ST
HT TOWER
HT RACK 19"
HT-B
HT-C SERIES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
COMPACT ST
FUNCTIONS AND FEATURES
→ Line Interactive Technology
→ AVR (Automatic Voltage Regulation)
→ Microprocessor control
→ LCD panel general control
→ Battery charge visible on panel
→ IEC output sockets for PC
→ USB Computer Interface
→ Protection RJ Fax / Modem /Phone
→ Software supervisory and shut-down
→ Battery maintenance free high current
→ Battery charger with digital control
→ USB interface
→ Response time <4ms
→ Self-Diagnostics
→ Self-learning frequency
750VA
1200VA
Options:
→ Available in version O.E.M
1600VA
COMPAC ST MODEL
POWER
INPUT
6 and 7 and 8
10 and 12
15 and 16
(VA)
650 and 750 and 800
1000 and 1200
1500 and 1600
(W)
360 and 400 and 480
620 and 720
900 and 1000
230 VAC±25%
VOLTAGE
50 OR 60 Hz ± 10% (AUTOSENSING)
FREQUENCY
230 VAC ± 9% (AVR)
VOLTAGE
OUTPUT
BY INPUT : SYNCHRONIZED BY NETWORK
FREQUENCY
PSEUDO-SINUWAVE
WAVE FORM
4
SOCKETS
BATTERY
6 - 8h
< 30 dBA (@ 1 m)
NOISE LEVEL
FROM 0°C TO 40°C
OPERATING TEMPERATURE
<90% NOT CONDENSING
RELATIVE HUMIDITY ( @35°C )
1510x410x835
DIMENSIONS UPS (WxDxH) mm
4,5
8,4
STANDARDS
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
ELECTRONIC
OVERLOAD - SHORT-CIRCUIT - BATTERY VOLTAGE LOW
10,2
INPUT FUSE
ELECTRIC
PROTECTIONS
MECHANICAL
IP21
RJ11
PROTECTION
SIGNALLING
2
10'
STD. BACK UP
WEIGHT (Kg)
12V-9Ah
1
NUMBER
RECHARGE TIME
GENERAL
NOTES
6
12V-7,2Ah
TYPE
TENSION PRESENCE - BATTERY MODE - OVERLOAD
OPTIC
POWER FAILURE - LOW BATTERIES - OVERLOAD
ACOUSTIC
APPLICATIONS :
ADMINISTRATIVE OFFICES, DOMESTIC, CCTV - VIDEO SURVEILLANCE
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
30 of 46
HT TOWER
FUNCTIONS AND FEATURES
→ Technology "on-line" double conversion
→ Transformerless
→ Input and output phase (sinusoidal)
→ High performance
→ PFC circuit input
→ Microprocessor control with Self-Diagnostics
→ Automatic bypass standard
→ LCD Display information on the status of the UPS
→ Setting the value of the output voltage
→ Ability to operate in ECO Mode Selectable
→ Ability Power by batteries (COLD START)
→ Automatic restart to return network
→ Automatic function test using keys
→ Management of the fan by the microprocessor
→ Telephone line protection with RJ45
→ Increased autonomy with battery box (opt)
→ RS232-USB interface and software for control
→ Contact emergency button (EPO) on version Plus
Options:
→ SNMP adapter and related software
→ Communication board alarm relay (AS/400)
→ Available in conformity with CEI 0-16
→ Increased autonomy with battery box
HT SAT ON-LINE MODEL
POWER
100
140-PLUS
200
240-PLUS
300
340-PLUS
(VA)
1000
1400
2000
2400
3000
3400
(W)
800
900
1600
1800
2400
2700
200/295VAC FULL LOAD
VOLTAGE
INPUT
40-55 TO 50Hz / 55-65Hz (AUTOSENSING)
FREQUENCY
> 0,98
POWER FACTOR
208/220/230/240 (sel ±2%)
VOLTAGE
50/60Hz ±0,2%
108% ±5%< LOAD ≤150% ±5% >30s LOAD DISCONNECT & ALARM
150% ±5%< LOAD <200% ±5% >300ms LOAD DISCONNECT & ALARM
SINUWAVE
FREQUENCY
OVERLOAD
OUTPUT
WAVE FORM
< 3% ( LINEAR LOAD )
THD
>90% ( VERSION PLUS >91%) - ECO MODE >98%
EFFICIENCY
SOCKETS
BY PASS
1+2 IEC 10A
12V-9Ah
12V-7Ah
4 IEC 10A
12V-7Ah
2
3
4
NUMBER
SIGNALLING
12V-9Ah
12V-9Ah
12V-9Ah
6
< 55 dBA (@ 1 m)
FROM 0°C TO 40°C
OPERATING TEMPERATURE
PROTECTIONS
4+4 IEC 10A
+1 IEC 16A
6 - 8h
NOISE LEVEL
> 90% NOT CONDENSING
RELATIVE HUMIDITY ( @35°C )
144x409x215
DIMENSIONS UPS (WxDxH) mm
WEIGHT (Kg)
4 IEC 10A
10'
STD. BACK UP
RECHARGE TIME
GENERAL
NOTES
4+4 IEC 10A
W/O INTERRUPTION (100%) UPS - BYPASS - UPS
AUTOMATIC
TYPE
BATTERY
3 IEC 10A
11
14
191x428x337
21
26
27
STANDARDS
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
ELECTRONIC
OVERLOAD - SHORT-CIRCUIT - BATTERY VOLTAGE LOW
ELECTRIC
MECHANICAL
INPUT FUSE
PROTECTION
RJ11
27,3
IP21
TENSION PRESENCE - BATTERY MODE - OVERLOAD
OPTIC
POWER FAILURE - LOW BATTERIES - OVERLOAD
ACOUSTIC
APPLICATIONS :
ADMINISTRATIVE OFFICES, DOMESTIC, CCTV - VIDEO SURVEILLANCE
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
31 of 46
HT RACK 19"
FUNCTIONS AND FEATURES
→ Technology "on-line" double conversion
→ Transformerless
→ Input and output phase (sinusoidal)
→ High performance
→ PFC circuit input
→ Microprocessor control with Self-Diagnostics
→ Automatic bypass standard
→ LCD Display information on the status of the UPS
→ Setting the value of the output voltage
→ Ability to operate in ECO Mode Selectable
→ Ability Power by batteries (COLD START)
→ Automatic restart to return network
→ Automatic function test using keys
→ Management of the fan by the microprocessor
→ Telephone line protection with RJ45
→ Increased autonomy with battery box (opt)
→ RS232-USB interface and software for control
→ Contact emergency button (EPO) on version Plus
Options:
→ SNMP adapter and related software
→ Communication board alarm relay (AS/400)
→ Available in conformity with CEI 0-16
→ Increased autonomy with battery box
HT RACK 19" MODEL
POWER
100
200
300
600
1000
(VA)
1000
2000
3000
6000
10000
(W)
800
1600
2400
5400
9000
200/295VAC FULL LOAD
VOLTAGE
INPUT
40-55 TO 50Hz / 55-65Hz (AUTOSENSING)
FREQUENCY
> 0,98
POWER FACTOR
208/220/230/240 (sel ±2%)
VOLTAGE
50/60Hz ±0,2%
FREQUENCY
108% ±5%< LOAD ≤150% ±5% >30s LOAD DISCONNECT & ALARM
OVERLOAD
OUTPUT
SINUWAVE
WAVE FORM
< 3% ( LINEAR LOAD )
THD
>90% ( VERSION PLUS >91%) - ECO MODE >98%
EFFICIENCY
SOCKETS
BY PASS
3 IEC 10A
NUMBER
12V-9Ah
12V-7Ah
12V-9Ah
2
4
6
12V-9Ah
12V-9Ah
16
< 55 dBA (@ 1 m)
FROM 0°C TO 40°C
OPERATING TEMPERATURE
> 90% NOT CONDENSING
RELATIVE HUMIDITY ( @35°C )
DIMENSIONS UPS (WxDxH) mm
440x380x86,5 (2U)
11
21
440x520x131 (3U)
27
18+50
STANDARDS
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
ELECTRONIC
OVERLOAD - SHORT-CIRCUIT - BATTERY VOLTAGE LOW
19+50
INPUT FUSE
ELECTRIC
PROTECTIONS
MECHANICAL
IP21
RJ11
PROTECTION
SIGNALLING
TERMINAL BOX
6 - 8h
NOISE LEVEL
WEIGHT (Kg)
TERMINAL BOX
10'
STD. BACK UP
RECHARGE TIME
GENERAL
NOTES
4 IEC 10A
W/O INTERRUPTION (100%) UPS - BYPASS - UPS
AUTOMATIC
TYPE
BATTERY
4 IEC 10A
TENSION PRESENCE - BATTERY MODE - OVERLOAD
OPTIC
POWER FAILURE - LOW BATTERIES - OVERLOAD
ACOUSTIC
APPLICATIONS :
ADMINISTRATIVE OFFICES, DOMESTIC, CCTV - VIDEO SURVEILLANCE
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
32 of 46
HT-B 6 - 10
FUNCTIONS AND FEATURES
→ Technology "on-line" double conversion
→ Transformerless
→ Input and output phase (sinusoidal)
→ High performance
→ PFC circuit input
→ Microprocessor control with Self-Diagnostics
→ Automatic bypass standard
→ LCD Display information on the status of the UPS
→ Setting the value of the output voltage
→ Ability to operate in ECO Mode Selectable
→ Ability Power by batteries (COLD START)
→ Automatic restart to return network
→ Automatic function test using keys
→ Management of the fan by the microprocessor
→ Telephone line protection with RJ45
→ Increased autonomy with battery box (opt)
→ RS232-USB interface and software for control
→ Contact emergency button (EPO) on version Plus
Options:
→ SNMP adapter and related software
→ Communication board alarm relay (AS/400)
→ Available in conformity with CEI 0-16
→ Increased autonomy with battery box
HT-B 6 - 10 MODEL
POWER
INPUT
6 kVA
6
10
(VA)
6000
10000
(W)
4200
7000
220/230VAC +20% / -25%
VOLTAGE
50/60Hz ± 5%
FREQUENCY
230 ± 3%
VOLTAGE
50/60Hz ±5%
FREQUENCY
OUTPUT
110% per 10 min; 130% per 1 min
OVERLOAD
SINUWAVE
WAVE FORM
< 3% ( LINEAR LOAD )
THD
BY PASS
EFFICIENCY
91%
AUTOMATIC
W/O INTERRUPTION (100%) UPS - BYPASS - UPS
12V-7,2Ah
TYPE
BATTERY
15'
STD. BACK UP
8h
< 45 dBA (@ 1 m)
NOISE LEVEL
FROM 0°C TO 40°C
OPERATING TEMPERATURE
RELATIVE HUMIDITY ( @35°C )
> 90% NOT CONDENSING
DIMENSIONS UPS (WxDxH) mm
270x570x720
95
98
UPSILON FOR WINDOWS, NOVEL, FREEBSD, LINUX
SOFTWARE
SIGNALLING
370x670x940
DIMENSIONS PACKAGE (WxDxH) mm
WEIGHT (Kg)
PROTECTIONS
12V-9Ah
20 PIC
NUMBER
RECHARGE TIME
GENERAL
NOTES
10kVA
STANDARDS
EN 62040-1-2, EMC EN 62040-2, EN 62040-3
ELECTRONIC
OVERLOAD - SHORT-CIRCUIT - BATTERY VOLTAGE LOW
ELECTRIC
MECHANICAL
INPUT FUSE
PROTECTION
RJ11
IP21
TENSION PRESENCE - BATTERY MODE - OVERLOAD
OPTIC
POWER FAILURE - LOW BATTERIES - OVERLOAD
ACOUSTIC
APPLICATIONS :
ADMINISTRATIVE OFFICES, DOMESTIC, CCTV - VIDEO SURVEILLANCE
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
33 of 46
HT-C Series
FUNCTIONS AND FEATURES
IGBT based power factor correction technology provides Input Power
Factor close to 1 (≥0.99) and keeps Input Current Total Harmonic
Distortion (THDi) less than 3%, that helps to avoid the disturbance.
(THDi) less than 3% avoids the disturbance to connected loads.
All of the control functions for HP-C Series UPS including power-on,
start-up control, input stage power factor control, battery charging and
boosting control, output stage ac voltage regulation and shut-down
control, can be realized by using a single DSP control board.
High Input Power Factor, 0,99 Input power factor ensures clean and
sinusoidal input current. The high input power leads to reduced
electricity pay-out, minimizes cable, switchboard, fuse and generator
requirements, thus reducing investment cost.
With its high efficiency up to 93% HP-C Series UPS consumes less
energy to supply the loads. Thanks to this high efficiency rate, the
percentage of energy that is produced as heat is reduced to a
miminum. As a result of decreased heat emission users can reduce
their electricity usage and air condition requirements.
HP-C Series includes standard static and manual bypass. Static
bypass provides safe failure to mains if the UPS is overloaded or
develops a fault condition. Where EMI filters are used to help to
neutralize spikes
p
and electrical noise, the load may
y be routed through
g
bypass to provide further protection. Manual bypass function is
intended only for maintenance work, this bypass supply is
incorporated into the HP-C UPS design. Manual bypass is used to
power down the UPS without interrupting the power to the load. With
this feature it is comp-letely safe for the technical personnel to work
HP-C is compatible with wide range of application. Flexibility achieved
through many choices, including type of battery, single or multi-unit
configuration, accessories and options.
* Frequency converter mode;
* Optional temperature sensor for external battery cabinets (to
assist the recharge voltage compensation);
* Additional battery chargers to optimize charge time;
* Optional separated bypass;
* Isolation transformers to vary neutral connectivity in the event of
separate power sources or for galvanic isolation between input
and output;
* Battery cabinets of different sizes and capacities, for providing
extended runtimes.
HP-C Series is perfectly compatible with diverse sources, especially
with generators. When generator power is used, thanks to its robust
IGBT rectifier, it ensures clean, uninterrupted power to protected
equipment.With high input power factor performance of HP-C Ups
series it is enough to choose generator with power only %20 higher
rated than the UPS. HP-C Series has the ability to adjust power walkin from 5 to 15 seconds, along with reduced input current distortion.
HP-C Series UPS has Large and user-friendly 320x240 LCD display
that provides operating information in four different languages.
Thanks to this advanced LCD display all parameters of working
device can be monitored and controlled.UPS is capable of recording
up to 500 events.
EPO function is designed to switch off the UPS in emergency
conditions ( fire, flood, etc.). The system will turn off the rectifier,
inverter and will stop powering the load immediately (including the
inverter and bypass) also the battery stops charging or discharging.
When the main and bypass sources fail, the UPS draws power from
the battery system to supply the load until the batteries are depleted.
When UPS will reach its end of discharge, it will shut down.
The UPS will automatically restart and enable output power:
* After utility power is restored;
* After the “Auto Start Delay Time” is expired (the default delay is
5 minutes) .
SINPEC_CT1501
The HP-C UPS can be used with regenerative loads, such as
synchronous motors. The regenerative loads pump the energy back
to mains, traditional Ups systems burn this feedback energy and this
causes lower efficiency. HP-C Series Ups with IGBT rectifier are able
to absorb intermittent load generated power. Additionally, this reverse
power tolerance permits execution of important system operations like
closed transition transfers of the UPS load directly to an engine
generator source.
HP-C Series guarantees enhanced battery life and maximizes battery
performance, life span and reliability through intelligent precision
charging. Temperature Compensated Battery Charging monitors
performing measurement of external and internal battery temperature
and adjusting the charge current rate accordingly. Advanced battery
management provides real-time information about battery capacity
and back up time, this information can be seen on LCD panel. The
Ups tests the batteries at adjustable periods without switching off the
system, the test periods can be set by users.
Hydrus Series features easy and simple scalability and redundancy.
It is ready to grow with your business demands. Different power rated
units and any number of UPS can be connected in parallel.
Power Increase:
The UPS's can be connected in parallel to increase total capacity of
the system. If one of the devices goes out of order, the critical loads
are transferred to by-pass.
Parallel Operation Features :
Internal standard parallel microprocessor for all models.
Up to 16 units parallelable
Parallel connection with ring cable
Autosensing disconnected parallel cable
Equal current share with DSP control
Easy power upgrade without any interruption
All parallel systems can be controlled from the front panelof one unit.
Full synchronization of parallel unitsIsolated parallel operation
dSt ti by-pass
b
f allll units
it
cardStatic
for
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
34 of 46
HT-C Series
FUNCTIONS AND FEATURES
HP-C Series is a true Online Double Conversion, new generation fully
digital controlled UPS. Its highly flexible design meets high efficiency and
high availibility power needs of a wide variety of critical applications and
delivers an advanced power solution with low cost of ownership.
Equipped with its new IGBT rectifier HP-C series keeps your critical loads
protected while its space-saving compact design and front access for
maintenance successfully reduce mean time to repair (MTTR). Thanks to
the wide variety of accessories and options HP-C Series presents
maximum flexibility advantage to users and optimizes total cost of
ownership.
→True On Line-Double Conversion Technology
→IGBT PWM Rectifier & Inverter Technology
→DSP Control
→Low Input Current THD (<3%)
→High Input Power Factor (>0.99)
→High Efficiency up to 93%
→Optional Dual Input
→Wide Input Voltage Range
→Advanced Battery Management
→Short Circuit and Overload Protection
→Unlimited Number of Paralellable Modules
→Selectable Number of Batteries
→500 Real Time Event Log with Detailed Parameters
→Static&Manual Bypass Operation
→Overload and Short Circuit Protection
→Small Footprint and Easy Maintenance
→Advanced Communication Capabilities
→Perfect Generator Compatibility
→Customizable as Frequency Converter
Options:
More autonomy on request
HT-C MODEL
POWER
10
15
20
30
40
60
(kVA)
10
15
20
30
40
60
(kW)
9
13 5
13,5
18
27
36
54
220/380VAC -15%+18% 3P+N+G OPTION 220/380VAC -37%+22%
VOLTAGE
INPUT
45-65HZ (SELECTABLE)
FREQUENCY
>0,99 AT FULL LOAD
POWER FACTOR
220/380Vac, 230/400Vac and 240/415Vac 3P+N
VOLTAGE
50HZ +/-0,05% - SYNCHRONOUS WITH THE NETWORK
FREQUENCY
OUTPUT
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC
OVERLOAD
TRUE SINE WAVE
WAVE FORM
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
THD
UP TO 94%, ECO MODE 98%
EFFICIENCY
INPUT VOLTAGE
NOMINAL VOLTAGE
BY-PASS
MAX SWITCHING TIME
0 (ZERO) STATIC BY-PASS
CURRENT OVERLOAD
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC COMMUTE IN BY-PASS
MAINTENANCE BY-PASS
MANUAL
BATTERY
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE
2x31
NUMBER
FROM 50 TO 55 DB (AT 1 MT)
NOISE LEVEL
0°C - 40°C
OPERATING TEMPERATURE
0-95%
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
AIR FORCED
COOLING SYSTEM
WEIGHT W/O BATTERIES (Kg)
120
125
150
160
180
EN62040-1-2-3 , ISO, CE
STANDARDS
IP21
PROTECTIONS MECHANICAL
4 LINES LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANELTOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
OPTIONS
115
RS232 AND EPO OPTION SNMP,MODBUS,RS485,REMOTE PANEL
COMUNICATION
SIGNALLING
460x805x1190
DIMENSIONS UPS (WxDxH) mm
BATTERY EXTENSION
YES OPT
ISOLATION TRANSFORMER
YES OPT
REMOTE PANEL
YES OPT
APPLICATIONS :
MEDICAL CENTERS, COMPUTERS NETWORK AND SERVERS BROADCASTING STATIONS, TECHNICAL AND ADMINISTRATIVE OFFICES,
LABORATORIES, BANKS, PRODUCTION LINES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
35 of 46
HT-C Series
FUNCTIONS AND FEATURES
HP-C Series is a true Online Double Conversion, new generation fully
digital controlled UPS. Its highly flexible design meets high efficiency and
high availibility power needs of a wide variety of critical applications and
delivers an advanced power solution with low cost of ownership.
Equipped with its new IGBT rectifier HP-C series keeps your critical loads
protected while its space-saving compact design and front access for
maintenance successfully reduce mean time to repair (MTTR). Thanks to
the wide variety of accessories and options HP-C Series presents
maximum flexibility advantage to users and optimizes total cost of
ownership.
→True On Line-Double Conversion Technology
→IGBT PWM Rectifier & Inverter Technology
→DSP Control
→Low Input Current THD (<3%)
→High Input Power Factor (>0.99)
→High Efficiency up to 93%
→Optional Dual Input
→Wide Input Voltage Range
→Advanced Battery Management
→Short Circuit and Overload Protection
→Unlimited Number of Paralellable Modules
→Selectable Number of Batteries
→500 Real Time Event Log with Detailed Parameters
→Static&Manual Bypass Operation
→Overload and Short Circuit Protection
→Small Footprint and Easy Maintenance
→Advanced Communication Capabilities
→Perfect Generator Compatibility
→Customizable as Frequency Converter
Options:
More autonomy on request
HT-C MODEL
POWER
80
100
120
(kVA)
80
100
120
(kW)
72
90
108
220/380VAC -15%+18% 3P+N+G OPTION 220/380VAC -37%+22%
VOLTAGE
INPUT
45-65HZ (SELECTABLE)
FREQUENCY
>0,99 AT FULL LOAD
POWER FACTOR
220/380VAC, 230/400VAC AND 240/415VAC 3P+N
VOLTAGE
50HZ +/-0,05% - SYNCHRONOUS WITH THE NETWORK
FREQUENCY
OUTPUT
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC
OVERLOAD
TRUE SINE WAVE
WAVE FORM
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
THD
UP TO 94%, ECO MODE 98%
EFFICIENCY
INPUT VOLTAGE
NOMINAL VOLTAGE
BY-PASS
MAX SWITCHING TIME
0 (ZERO) STATIC BY-PASS
CURRENT OVERLOAD
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC COMMUTE IN BY-PASS
MAINTENANCE BY-PASS
MANUAL
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE (Separate Cabinet)
BATTERY
2x31
NUMBER
NOMINAL 0,1 C - ADJUSTABLE
CHARGE VALUE "C"
YES SERIES
STATIC SWITCH
FROM 50 TO 55 dB (@ 1 MT)
NOISE LEVEL
0°C - 40°C
OPERATING TEMPERATURE
GENERAL
NOTES
AIR FORCED
COOLING SYSTEM
300
320
350
RS232 AND EPO OPTION SNMP,MODBUS,RS485,REMOTE PANEL
COMUNICATION
EN62040-1-2-3 , ISO, CE
STANDARDS
IP21
PROTECTIONS MECHANICAL
4 LINES LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANELTOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
OPTIONS
880x770x1660
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
SIGNALLING
0-95%
RELATIVE HUMIDITY ( @35°C )
BATTERY EXTENSION
YES OPT
ISOLATION TRANSFORMER
YES OPT
REMOTE PANEL
YES OPT
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
36 of 46
HT-C Series
FUNCTIONS AND FEATURES
HP-C Series is a true Online Double Conversion, new generation fully
digital controlled UPS. Its highly flexible design meets high efficiency and
high availibility power needs of a wide variety of critical applications and
delivers an advanced power solution with low cost of ownership.
Equipped with its new IGBT rectifier HP-C series keeps your critical loads
protected while its space-saving compact design and front access for
maintenance successfully reduce mean time to repair (MTTR). Thanks to
the wide variety of accessories and options HP-C Series presents
maximum flexibility advantage to users and optimizes total cost of
ownership.
→True On Line-Double Conversion Technology
→IGBT PWM Rectifier & Inverter Technology
→DSP Control
→Low Input Current THD (<3%)
→High Input Power Factor (>0.99)
→High Efficiency up to 93%
→Optional Dual Input
→Wide Input Voltage Range
→Advanced Battery Management
→Short Circuit and Overload Protection
→Unlimited Number of Paralellable Modules
→Selectable Number of Batteries
→500 Real Time Event Log with Detailed Parameters
→Static&Manual Bypass Operation
→Overload and Short Circuit Protection
→Small Footprint and Easy Maintenance
→Advanced Communication Capabilities
→Perfect Generator Compatibility
→Customizable as Frequency Converter
Options:
More autonomy on request
HT-C MODEL
POWER
160
200
(kVA)
160
200
(kW)
144
180
220/380VAC -15%+18%
15% 18% 3P+N+G
3P N G OPTION 220/380VAC -37%+22%
37% 22%
VOLTAGE
INPUT
45-65HZ (SELECTABLE)
FREQUENCY
>0,99 AT FULL LOAD
POWER FACTOR
220/380VAC, 230/400VAC AND 240/415VAC 3P+N
VOLTAGE
50HZ +/-0,05% - SYNCHRONOUS WITH THE NETWORK
FREQUENCY
OUTPUT
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC
OVERLOAD
TRUE SINE WAVE
WAVE FORM
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
THD
UP TO 94%, ECO MODE 98%
EFFICIENCY
INPUT VOLTAGE
NOMINAL VOLTAGE
BY-PASS
MAX SWITCHING TIME
0 (ZERO) STATIC BY-PASS
CURRENT OVERLOAD
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC COMMUTE IN BY-PASS
MAINTENANCE BY-PASS
MANUAL
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE (Separate Cabinet)
BATTERY
2x31
NUMBER
NOMINAL 0,1 C - ADJUSTABLE
CHARGE VALUE "C"
YES SERIES
STATIC SWITCH
FROM 50 TO 55 dB (@ 1 MT)
NOISE LEVEL
0°C - 40°C
OPERATING TEMPERATURE
GENERAL
NOTES
AIR FORCED
COOLING SYSTEM
550
575
RS232 AND EPO OPTION SNMP,MODBUS,RS485,REMOTE PANEL
COMUNICATION
EN62040-1-2-3 , ISO, CE
STANDARDS
IP21
PROTECTIONS MECHANICAL
4 LINES LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANELTOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
OPTIONS
1055x815x1905
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
SIGNALLING
0-95%
RELATIVE HUMIDITY ( @35°C )
BATTERY EXTENSION
YES OPT
ISOLATION TRANSFORMER
YES OPT
REMOTE PANEL
YES OPT
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
37 of 46
HT-C Series
FUNCTIONS AND FEATURES
HP-C Series is a true Online Double Conversion, new generation fully
digital controlled UPS. Its highly flexible design meets high efficiency and
high availibility power needs of a wide variety of critical applications and
delivers an advanced power solution with low cost of ownership.
Equipped with its new IGBT rectifier HP-C series keeps your critical loads
protected while its space-saving compact design and front access for
maintenance successfully reduce mean time to repair (MTTR). Thanks to
the wide variety of accessories and options HP-C Series presents
maximum flexibility advantage to users and optimizes total cost of
ownership.
→True On Line-Double Conversion Technology
→IGBT PWM Rectifier & Inverter Technology
→DSP Control
→Low Input Current THD (<3%)
→High Input Power Factor (>0.99)
→High Efficiency up to 93%
→Optional Dual Input
→Wide Input Voltage Range
→Advanced Battery Management
→Short Circuit and Overload Protection
→Unlimited Number of Paralellable Modules
→Selectable Number of Batteries
→500 Real Time Event Log with Detailed Parameters
→Static&Manual Bypass Operation
→Overload and Short Circuit Protection
→Small Footprint and Easy Maintenance
→Advanced Communication Capabilities
→Perfect Generator Compatibility
→Customizable as Frequency Converter
Options:
More autonomy on request
HT-C MODEL
POWER
250
300
400
(kVA)
250
300
400
(kW)
225
270
360
220/380VAC -15%+18% 3P+N+G OPTION 220/380VAC -37%+22%
VOLTAGE
INPUT
45-65HZ (SELECTABLE)
FREQUENCY
>0,99 AT FULL LOAD
POWER FACTOR
220/380Vac, 230/400Vac and 240/415Vac 3P+N
VOLTAGE
50HZ +/-0,05% - SYNCHRONOUS WITH THE NETWORK
FREQUENCY
OUTPUT
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC
OVERLOAD
TRUE SINE WAVE
WAVE FORM
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
THD
UP TO 94%, ECO MODE 98%
EFFICIENCY
INPUT VOLTAGE
NOMINAL VOLTAGE
BY-PASS
MAX SWITCHING TIME
0 (ZERO) STATIC BY-PASS
CURRENT OVERLOAD
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC COMMUTE IN BY-PASS
MAINTENANCE BY-PASS
MANUAL
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE (Separate Cabinet)
BATTERY
2x31
NUMBER
NOMINAL 0,1 C - ADJUSTABLE
CHARGE VALUE "C"
YES SERIES
STATIC SWITCH
FROM 50 TO 55 dB (@ 1 MT)
NOISE LEVEL
0°C - 40°C
OPERATING TEMPERATURE
GENERAL
NOTES
AIR FORCED
COOLING SYSTEM
700
750
1250
RS232 AND EPO OPTION SNMP,MODBUS,RS485,REMOTE PANEL
COMUNICATION
EN62040-1-2-3 , ISO, CE
STANDARDS
IP21
PROTECTIONS MECHANICAL
4 LINES LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANELTOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
OPTIONS
1250x815x1905
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
SIGNALLING
0-95%
RELATIVE HUMIDITY ( @35°C )
BATTERY EXTENSION
YES OPT
ISOLATION TRANSFORMER
YES OPT
REMOTE PANEL
YES OPT
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
38 of 46
HP-C Series
FUNCTIONS AND FEATURES
HP-C Series is a true Online Double Conversion, new generation fully
digital controlled UPS. Its highly flexible design meets high efficiency and
high availibility power needs of a wide variety of critical applications and
delivers an advanced power solution with low cost of ownership.
Equipped with its new IGBT rectifier HP-C series keeps your critical loads
protected while its space-saving compact design and front access for
maintenance successfully reduce mean time to repair (MTTR). Thanks to
the wide variety of accessories and options HP-C Series presents
maximum flexibility advantage to users and optimizes total cost of
ownership.
→True On Line-Double Conversion Technology
→IGBT PWM Rectifier & Inverter Technology
→DSP Control
→Low Input Current THD (<3%)
→High Input Power Factor (>0.99)
→High Efficiency up to 93%
→Optional Dual Input
→Wide Input Voltage Range
→Advanced Battery Management
→Short Circuit and Overload Protection
→Unlimited Number of Paralellable Modules
→Selectable Number of Batteries
→500 Real Time Event Log with Detailed Parameters
→Static&Manual Bypass Operation
→Overload and Short Circuit Protection
→Small Footprint and Easy Maintenance
→Advanced Communication Capabilities
→Perfect Generator Compatibility
→Customizable as Frequency Converter
Options:
More autonomy on request
HT-C MODEL
POWER
500
600
(kVA)
500
600
(kW)
450
540
220/380VAC -15%+18% 3P+N+G OPTION 220/380VAC -37%+22%
VOLTAGE
INPUT
45-65HZ (SELECTABLE)
FREQUENCY
>0,99 AT FULL LOAD
POWER FACTOR
220/380Vac, 230/400Vac and 240/415Vac 3P+N
VOLTAGE
50HZ +/-0,05% - SYNCHRONOUS WITH THE NETWORK
FREQUENCY
OUTPUT
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC
OVERLOAD
WAVE FORM
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
THD
WITH LINEAR LOAD <2% - WITH NON LINEAR LOAD <6%
UP TO 94%, ECO MODE 98%
EFFICIENCY
INPUT VOLTAGE
NOMINAL VOLTAGE
BY-PASS
MAX SWITCHING TIME
0 (ZERO) STATIC BY-PASS
CURRENT OVERLOAD
AT 125% LOAD 10MIN. - AT 150% LOAD 60SEC COMMUTE IN BY-PASS
MAINTENANCE BY-PASS
MANUAL
LEAD-ACID OR NICD, VRLA OR FLOODED
TYPE (Separate Cabinet)
BATTERY
2x31
NUMBER
NOMINAL 0,1 C - ADJUSTABLE
CHARGE VALUE "C"
YES SERIES
STATIC SWITCH
FROM 50 TO 55 dB (@ 1 MT)
NOISE LEVEL
0°C - 40°C
OPERATING TEMPERATURE
GENERAL
NOTES
AIR FORCED
COOLING SYSTEM
1600
1800
RS232 AND EPO OPTION SNMP,MODBUS,RS485,REMOTE PANEL
COMUNICATION
EN62040-1-2-3 , ISO, CE
STANDARDS
IP21
PROTECTIONS MECHANICAL
4 LINES LCD PANEL,MIMIC LEDS,5 VECTOR BUTTONS,BUZZER - OPTIONAL GRAPHICAL PANELTOUCH PANEL
OPTIC
POWER FAILURE - BATTERIES - OVERLOAD - START BATTERY TEST
ACOUSTIC
OPTIONS
1830x850x2010
DIMENSIONS UPS (WxDxH) mm
WEIGHT W/O BATTERIES (Kg)
SIGNALLING
0-95%
RELATIVE HUMIDITY ( @35°C )
BATTERY EXTENSION
YES OPT
ISOLATION TRANSFORMER
YES OPT
REMOTE PANEL
YES OPT
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
39 of 46
VARIOUS
MEC VOLTAGE REGULATORS
PV SYSTEMS SOLAR SERIES
POWER GENERATOR
BATTERIES
HARMONIC PASSIVE SYSTEM
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
MEC
FUNCTIONS AND FEATURES
VOLTAGE REGULATORS
Are based on the control of voltage variations through the
motorization of a autotrasformatore variable, coupled to an
autotransformer. By varying the voltage, a control card provides to
move the variable autotransformer, which, in turn, pilot the
autotransformer re-establishing the reference voltage. Currently
represent the best compromise in terms of performance, safety,
speed control, and its insensitivity to the load power factor, price.
Indispensable for high loads.
→ Degree of stabilization
±1%
→ Response time
4msec/1V
→ Mains frequency
from 42 at 60Hz
→ Harmonic distortion
<1%
→ Efficiency at full load
>95%
→ Ambient temperature
0-30°C
→ Power factor of the load
any
→ Regulation the medium voltage & change in V/in
±15%
Options:
→ Available powers up to 1680 kVA
→ Electronic model
MEC MODEL
POWER (kVA)
WEIGHT (Kg)
DIM. (WxDxH) mm
MEC120
1,2
16
300 x 300 x 240
MEC200
2
19
301 x 300 x 240
MEC400
4
22
302 x 300 x 240
MEC600
6
26
300 x 520 x 240
MEC1000
10
36
301 x 520 x 240
MEC1500
15
44
302 x 520 x 240
MEC2000
20
85
303 x 520 x 240
MEC2500
25
105
580 x 280 x 900
MEC3000
30
125
581 x 280 x 900
MEC4500
45
175
650 x 400 x 1100
MEC600
6
70
230 x 490 x 490
MEC1200
12
80
230 x 490 x 490
MEC1800
18
105
580 x 280 x 900
MEC2400
24
140
581 x 280 x 900
MEC3000
30
160
582 x 280 x 900
MEC5000
50
180
650 x 400 x 1000
MEC6000
60
300
651 x 400 x 1000
MEC7500
75
380
652 x 400 x 1000
MEC10000
100
450
653 x 400 x 1000
MEC13500
135
500
900 x 500 x 1200
MEC15000
150
600
901 x 500 x 1200
MEC17500
175
780
902 x 500 x 1200
MEC23000
230
1100
605 x 850 x 1650
APPLICATIONS :
MEDICAL CENTERS, IT NETWORKS, ENTERPRISE SERVERS, TELECOMMUNICATIONS, INDUSTRIAL PROCESSES
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
41 of 46
PV SYSTEM
TYPICAL EXAMPLE OF STAND ALONE SYSTEM WTH RESCUE NETWORK
FUNCTIONS AND FEATURES
The range of products on solar stand-alone consists of three different products:
- The SolarBAT, smart charger, equipped with MPPT to optimize the energy supplied by the panels and charge the
batteries in faster way;
- The SolarINV, power inverter at high yield with a perfect sinusoidal wave, complete of isolation transformer on
output and full management of the hysteresis on the return DC;
- The SolarCOM, bypass to prioritize the power and to switch the load on the network in case of possible inverter
shutdown due to battery discharge occured.
All three products have different range of powers, in order to better meet the needs of the customer, and, although the working voltage
choice by SINPEC is 110 volts, in order to optimize the efficiency of the system, are also available to 48 VDC.
Also, having three separate devices for a proper assembly, provides better flexibility to the customer needs.
The custom products, then, are certainly the strong suit of SINPEC POWER SYSTEM, so do not hesitate to ask for customized solutions.
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
42 of 46
SolarBAT
SOLAR CHARGER WITH MPPT
FEATURES
* System switching CoolMOS, low loss
at high frequency;
* Wide DC input range;
* Management Microprocessor;
* DC output suitable for charging
batteries of wide size;
* Limiting inrush current at power run;
* Efficiency DC / DC very high;
* MPPT to optimize the input power.
* System CC / CV with battery
temperature sensor for correction of
output voltage;
* Self-diagnosis of faults
* Simple LED interface;
* Not isolated.
OPTIONS
* RS232 interface;
* SNMP adapter;
SOLARBAT
POWER
INPUT
(W)
1000
2000
3000
1000
2000
3000
330 Vdc ( Max applicabile 450 Vdc)
NOMINAL INPUT DC
110 Vdc
NOMINAL OUTPUT DC
10
MAX CURRENT (A)
RANGE VOLTAGE INPUT MPPT
OUTPUT
< 2% AT FULL LOAD (LINEAR)
TDH
OUTPUT FUSE
98%
PERFORMANCE
INPUT TERMINALS / OUTPUT TERMINALS WITH EXTERNAL BATTERY SENSOR
INPUT AND OUTPUT
<40
NOISE (dbA @ 1 m)
OPERATING TEMPERATURE
SIGNALLING
RELATIVE HUMIDITY ( @35°C )
DIMENSIONS (W x P x H) mm
FROM 0°C TO 40°C
> 90% NOT CORROSIVE
200x230x130 - OPTION: RACK 2U
WEIGHT (Kg)
10
STANDARDS
EN 50091-1-2, EMC EN 50091-2, CSS EN 50171
OPTIC
30
DC-TYPE CONSTANT CURRENT / CONSTANT VOLTAGE
CHARGING SYSTEM
OVERLOAD
GENERAL
NOTES
20
150/400 Vdc
LEDS STATUS, OVERLOAD, FAULTS
APPLICATIONS :
HOME, INDUSTRIAL
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
43 of 46
SolarINV
INVERTER FROM 1 TO 6 kVA
FEATURES
* Inverter MOSFET with low loss at
high frequency /high efficiency;
* DC wide input range;
* Single-phase sinusoidal output
230Vac;
* Output Isolation transformer ,
inverter;
* Limiting inrush current at power run;
* DSP inverter control and
microprocessor for managing user
interfaces;
* Display + leds for a clearer
information of the inverter status
* Self-diagnosis of faults;
OPTIONS
* Sync input (TTL);
* E.P.O.;
* Alarms on clean contact;
* Internal static bypass;
* Communication interface (RS232)
and software of control and
management;
SOLARINV
POWER
INPUT
(W)
1000
1500
2000
3000
4000
5000
6000
1000
1500
2000
3000
4000
5000
6000
330 Vdc ( MAX APPLICABLE 450 Vdc)
NOMINAL INPUT DC
24 / 48 / 60 / 110 / 220 / 250 Vdc (SPECIFY ON P.O.)
VOLTAGE PHASE
50Hz +/- 0,05%
FREQUENCY
110% FOR 60 SEC - 130% FOR 10 SEC - SHORT CIRCUIT MANAGEMENT
OVERLOAD
OUTPUT
SINUWAVE
WAVE FORM
< 2% AT FULL LOAD (LINEAR)
TDH
92%
EFFICIENCY FULL LOAD
230 Vac 50 Hz (60 Hz optional)
OUTPUT
<40
NOISE (dbA @ 1 m)
FROM 0°C TO 40°C
OPERATING TEMPERATURE
> 90% NOT CORROSIVE
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
DIMENSIONS (W x P x H) mm
DIMENSIONS PACKAGE(W x P x H) mm
WEIGHT (Kg)
483 x 475
x 133 (3U)
483 x 475 x 222 (5U)
630 x 570 x 220
630 x 570 x
270
650 x 570 x 440 (5U)
20
24
27
35
37
STANDARDS
EN 62040-1, EMC EN 62040-2, EN 62040-3
ELECTRONIC
OVERLOAD, SHORT-CIRCUIT, VOLTAGE MIN/MAX INPUT, UNDER VOLTAGE OUTPUT
PROTECTIONS ELECTRICAL
MECHANICAL
SIGNALLING
18
483 x 355 x 95 (2U)
OPTIC
OCOUSTIC
INPUT FUSE
IP21
STATUS & INVERTER OPERATION, OVERLOAD, FAULTS
OVERLOAD, SHORT-CIRCUIT, VOLTAGE MIN/MAX INPUT, UNDER VOLTAGE OUTPUT
APPLICATIONS :
HOME, INDUSTRIAL
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
44 of 46
SolarCOM
STATIC SWITCH
* MONOPHASE 5 to 20 kVA
* TRIPHASE 3x5 to 3x20 kVA
FEATURES
*
*
*
*
*
*
*
5
MONOPHASE
10
20
5
TRIPHASE
10
20
(kVA)
5
10
20
3x5
3x10
3x20
(A)
22
44
88
22 phase
44 phase
88 phase
SOLARCOM
POWER
INPUT
n. 2 230 Vac +/-15%
VOLTAGE
3x230 Vac +/-15% (F+N in common)
50 Hz
FREQUENCY
n. 2 230 Vac +/-15%
VOLTAGE
3x230 Vac +/-15% (F+N in common)
50 Hz
FREQUENCY
OUTPUT
110% per 60sec - 130% per 10sec
OVERLOAD
SINUWAVE
WAVE FORM
ELECTRICAL TERMINALS
IN/OUT
99%
EFFICIENCY FULL LOAD
<40
NOISE (dbA @ 1 m)
FROM 0°C TO 40°C
OPERATING TEMPERATURE
> 90% NOT CORROSIVE
RELATIVE HUMIDITY ( @35°C )
GENERAL
NOTES
SIGNALLING
483 x 334 x 90 (2U)
RACK DIMENSIONS (W x P x H) mm
540 x 410 x 165
RACK DIMENSIONS (W x P x H) mm
DIMENSIONS (W x P x H) mm
325 x 180 x 425
430x210x500
430x200x650
540x260x650
DIMENSIONS PACKAGE (WxDxH) mm
340 x 200 x 480
440x230x550
440x220x700
550x280x700
WEIGHT (Kg)
PROTECTIONS
Two inputs (F+N common)
Priority line selectable
AC Output
Microprocessor of control
Ease use
Leds for status information
Solid neutral
10
18
11
STANDARDS
EN 62310-1, EMC EN 62340-2
ELECTRICAL
BREACKERS OR FUSES
MECHANICAL
OPTIC
IP20
TENSION PRESENCE INLET AND OUTLET
APPLICATIONS :
HOME, INDUSTRIAL
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
45 of 46
VARIOUS
ELECTRICAL POWER GENERATOR
→ Generating sets with gasoline / diesel engine soundproof 3000 RPM
→ Generating sets with gasoline / diesel engine open frame 3000 RPM
→ Generating sets with air / water-cooled from 10 to 30kva 1500 RPM
→ Iveco Aifo powered generating sets - water-cooled from 30 to 450 Kva
→ John Deere powered generating sets - water-cooled from 30 to 180 kVA
→ Volvo powered generating sets - water-cooled - from 85 to 570 kVA
→ Deutz powered generating sets - liquid-cooled from 30 to 500 kVA
→ Perkins powered generating sets - water-cooled from 30 to 550 kVA
→ Perkins powered generating sets - water-cooled from 640 to 1020kVA
→ Mtu powered generating sets - water-cooled – from 640 to 1020kVA
→ Cummins powered generating sets -water-cooled from 640 to 1020 kVA
→ Volvo 640kVA – Iveco 720kVA powered generating sets -water-cooled
→ Shelter and container for Generating
POWER FROM 1kVA TO 1265kVA
BATTERIES
→ AGM batteries Standard life
→ AGM batteries Long Life (10 years design life)
→ AGM batteries Cyclic use
→ GEL batteries for light traction
→ GEL batteries for solar applications
→ GEL batteries for marine applications
→ Starter Batteries
PHOTOVOLTAIC SOLAR PANELS COMPLETE W/ INVERTERS
→ Inverters
→ Panels
→ Other components
HARMONIC COMPENSATION PASSIVE SYSTEM
→ different types of filters suitable for the solution of the harmonic generation due
to the operation of electrical apparatuses with absorption of non-linear type,
studied and realized for each specific application and Power Factor Correction.
FOR SPECIFICATIONS, PRICES AND MORE INFORMATION PLEASE CONTACT US
SINPEC_CT1501
SINPEC POWER SYSTEM reserves the right to modify this document without any notice.
Data and Imagines shown are subject to change without notice and do not engage the manufacturer.
46 of 46
Was this manual useful for you? yes no
Thank you for your participation!