NEC Express5800/R120d-2E SR User's Guide

NEC Express5800/R120d-2E SR User's Guide
Appendix C : Logs/Events
The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log.
[Event Source, Alert Type]
Source Name of Event Log (only Windows) : raidsrv
Alert Type : URAIDUTL
[Log]
Mark
Description
R
Universal RAID Utility logs this event to RAID Log.
O
Universal RAID Utility logs this event to OS log.
[Alert]
Mark
M and MA
Description
Universal RAID Utility send this event to NEC ESMPRO Manager as alert.
[ Address ] description in [Description]
The [ Address ] description is different from the category of event.
Category of Event
Type
Description
RAID Controller
Battery
1
[CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
Physical Device
2
[CTRL:%1(ID=%2) PD:%3(ID=%4) %5%6]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Vendor and Model of Physical Device
%6 : Firmware Version of Physical Device
Logical Drive
3
[CTRL:%1(ID=%2) LD:%3(ID=%4)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
Enclosure
4
[CTRL:%1(ID=%2) ENC:%3]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
Power Supply Unit in Enclosure
5
[CTRL:%1(ID=%2) ENC:%3 POW:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
Fan Unit in Enclosure
6
[CTRL:%1(ID=%2) ENC:%3 FAN:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
1
[priority, facility]
The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX.
kind
priority
facility
information
info
daemon
warning
warning
daemon
error
err
daemon
2
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
(hex digit)
0201
(400000C9)
0202
(400000CA)
0203
(400000CB)
0204
(400000CC)
0205
(400000CD)
0206
(400000CE)
0207
(400000CF)
0208
(400000D0)
0209
(400000D1)
0210
(400000D2)
0211
(800000D3)
0212
(C00000D4)
0213
(400000D5)
0214
(400000D6)
0215
(400000D7)
0216
(400000D8)
0217
(C00000D9)
0218
(C00000DA)
Information
[Address Type 1 ] The buzzer of RAID Controller is enable.
R
Information
[Address Type 1 ] The buzzer of RAID Controller is disable.
R
Information
R
Information
[Address Type 1 ] The Rebuild Priority of RAID Controller was
changed. (Value : %1)
[Address Type 1 ] The Consistency Check Priority of RAID
Controller was changed. (Value: %1)
[Address Type 1 ] The Initialize Priority of RAID Controller
was changed. (Value : %1)
[Address Type 1 ] Auto Patrol Read function is enable.
Information
[Address Type 1 ] Auto Patrol Read function is disable.
R
Information
R
Information
[Address Type 1 ] A Patrol Read Priority of RAID Controller
was changed. (Value : %1)
[Address Type 1 ] Patrol Read was started.
R
Information
[Address Type 1 ] Patrol Read completed.
R
Information
Information
R
R
R
[Address Type 1 ] A Warning Error happened to RAID
Controller. Detail : %1
RO
M
RAID Controller Warning
RO
MA
RAID Controller Fatal
Information
[Address Type 1 ] A Fatal Error happened to RAID Controller.
Detail : %1
[Address Type 1 ] Patrol Read was paused.
Information
[Address Type 1 ] Patrol Read was resumed.
R
Information
[Address Type 1 ] Patrol Read was queued.
R
Information
[Address Type 1 ] Patrol Read was stopped.
R
Warning
Fatal
Please check the RAID Controller. If some kind of
problem happens to the RAID Controller repeatedly,
please replace it.
Please replace the RAID Controller.
R
Fatal
[Address Type 1 ] Patrol Read failed.
RO
MA
Patrol Read Failed
Fatal
[Address Type 1 ] A Fatal Firmware Error happened to RAID
Controller. %1
RO
MA
RAID
Controller
Firmware Error
3
Please disable the setting of Patrol Read and then
enable it to retry Patrol Read. If Patrol Read fails again,
the RAID System may have some problems. Please deal
with the problem of the RAID System and retry Patrol
Read.
Fatal Please replace the RAID Controller.
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
(hex digit)
0219
(400000DB)
0301
(4000012D)
0302
(4000012E)
0303
(4000012F)
0304
(C0000130)
0305
(80000131)
0306
(40000132)
0307
(40000133)
0308
(C0000134)
0309
(40000135)
0311
(40000137)
0312
(40000138)
0313
(40000139)
0314
(4000013A)
0315
(4000013B)
0316
(4000013C)
0317
(8000013D)
Information
[Address Type 1 ] RAID Controller property was changed.
RO
Information
[Address Type 2 ] Physical Device is Online.
RO
M
Physical Device Online
None
Information
[Address Type 2 ] Physical Device is Ready.
RO
M
Physical Device Ready
None
Information
[Address Type 2 ] Physical Device is Hot Spare.
RO
M
Physical Device Hot Spare
None
Fatal
[Address Type 2 ] Physical Device is Failed.
RO
MA
Physical Device Failed
Please replace the Physical Device.
Warning
[Address Type 2 ] Detected S.M.A.R.T. Error.
RO
MA
S.M.A.R.T. Error
Please replace the Physical Device.
Information
[Address Type 2 ] Rebuild was started.
RO
MA
Rebuild Started
None
Information
[Address Type 2 ] Rebuild completed.
RO
MA
Rebuild Completed
None
[Address Type 2 ] Rebuild failed.
RO
MA
Rebuild Failed
Please replace the Physical Device.
Information
[Address Type 2 ] Rebuild was stopped.
RO
MA
Rebuild Stopped
None
Information
[Address Type 2 ] Physical Device was inserted.
RO
M
Physical Device Inserted
None
Information
[Address Type 2 ] Physical Device was removed.
RO
M
Physical Device Removed
None
Information
[Address Type 2 ] Global Hot Spare created.
R
Information
[Address Type 2 ] Dedicated Hot Spare created.
R
Information
[Address Type 2 ] Global Hot Spare removed.
R
Information
[Address Type 2 ] Dedicated Hot Spare removed.
R
0318
(C000013E)
0319
(4000013F)
Fatal
Fatal
Warning
Information
[Address Type 2 ] A Warning Error happened to Physical
Device. Detail : %1
RO
M
Physical Device Warning
[Address Type 2 ] A Fatal Error happened to Physical Device.
Detail : %1
[Address Type 2 ] Medium Error was detected in Physical
Device and corrected. %1
RO
MA
Physical Device Fatal
Please check the Physical Device. If some kind of
problem happens to the Physical Device repeatedly,
please replace it.
Please replace the Physical Device.
RO
MA
Physical Device Medium
Error(Correctable)
Please replace the Physical Device if too many errors
are detected on a Physical Device.
4
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
RO
MA
Physical Device Medium
Error(Uncorrectable)
Please replace the Physical Device if too many errors
are detected on a Physical Device.
MA
Physical Device Medium
Error Detected
Please replace the Physical Device if too many errors
are detected on a Physical Device.
RO
MA
Please replace the Physical Device.
If there is Hot Spare, RAID System will rebuild
automatically. If there is not it, please replace the
Physical Device and rebuild it.
Please replace the Physical Device and remake the
Logical Drive. Next restore the backup data to the
Logical Drive.
(hex digit)
0320
(C0000140)
Fatal
0321
(40000141)
0322
(40000142)
0323
(40000143)
0324
(80000144)
Information
[Address Type 2 ] Medium Error was detected in Physical
Device but could not correct. %1
%1 : Logical Block Address
[Address Type 2 ] Rebuild was paused.
Information
[Address Type 2 ] Rebuild was resumed.
R
Information
[Address Type 2 ] Rebuild was queued.
R
Warning
[Address Type 2 ] Medium Error was detected in Physical
Device. %1
%1 : Logical Block Address
[Address Type 2 ] Physical Device Power Status is
Transitioning.
[Address Type 2 ] Physical Device Power Status is On.
R
RO
0325
(40000145)
0326
(40000146)
0327
(40000147)
0328
(C0000148)
0401
(40000191)
0402
(80000192)
Information
0403
(C0000193)
Fatal
0404
(40000194)
0405
(40000195)
0406
(C0000196)
Information
[Address Type 3 ] Initialization was started.
R
Information
[Address Type 3 ] Initialization completed.
R
0407
(40000197)
0409
(40000199)
Information
[Address Type 3 ] Initialization was stopped.
R
Information
[Address Type 3 ] Consistency Check was started.
R
Information
Information
Fatal
Information
Warning
Fatal
RO
RO
[Address Type 2 ] Physical Device Power Status is Power
Saving.
[Address Type 2 ] Physical Device Power Status Change
failed.
[Address Type 3 ] Logical Drive is Online.
RO
RO
M
Physical Device Power
Status Change Failed
Logical Drive Online
[Address Type 3 ] Logical Drive is Degraded.
RO
MA
Logical Drive Degraded
[Address Type 3 ] Logical Drive is Offline.
RO
MA
Logical Drive Offline
MA
Initialization Failed
[Address Type 3 ] Initialization failed.
RO
5
None
Please retry Initialization. If Initialization failed
repeatedly, the RAID System may have some kind of
problem. Please deal with the problem of the RAID
System.
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
(hex digit)
[Address Type 3 ] Consistency Check completed.
0410
(4000019A)
0411
(C000019B)
Information
0412
(4000019C)
0413
(C000019D)
Information
0415
(4000019F)
0416
(400001A0)
0417
(400001A1)
Information
[Address Type 3 ] Logical Drive was created.
R
Information
[Address Type 3 ] Logical Drive was deleted.
R
Information
RO
R
Fatal
Fatal
[Address Type 3 ] Consistency Check failed.
[Address Type 3 ] Consistency Check was stopped.
[Address Type 3 ] Data Inconsistency was detected in
Logical Drive by Consistency Check and corrected.
R
RO
MA
Consistency Check Failed
Please retry Consistency Check. If Consistency Check
failed repeatedly, the RAID System may have some kind
of problem. Please deal with the problem of the RAID
System.
MA
Data Inconsistency Error
Corrected
Please execute Consistency Check again when the load
of the system is low. If the error does not occur on the
second time of Consistency Check, the Physical Device
does not have any problems. If the same error occurs,
please replace the Physical Device for the preventive
maintenance (please be sure to ask NEC customer
service before the replacement to identify which
Physical Device has a failure). After replacing the
Physical Device, restore the backup data to the Logical
Drive.
M
Cache Mode Changed
None
MA
Background Initialization
Failed
The RAID System may have some kind of problem.
Please deal with the problem of the RAID System.
Please replace the Physical Device (You need to ask it
which Physical Device do you replace). After
replacement of Physical Device, remake the Logical
Drive and restore the backup data to it.
Please replace the Physical Device for the prevention of
failure(You need to ask it which Physical Device do you
replace). Next restore the backup data to the Logical
Drive after replacement of Physical Device.
R
RO
0418
(400001A2)
0419
(400001A3)
0420
(800001A4)
0421
(400001A5)
0422
(C00001A6)
Information
[Address Type 3 ] The Cache Mode of Logical Drive was
changed. (Value : %1)
%1 : Changed value *1
[Address Type 3 ] Background Initialization was started.
Information
[Address Type 3 ] Background Initialization completed.
Fatal
[Address Type 3 ] An error was detected in Logical Drive but
could not correct.
RO
MA
Logical Drive
Uncorrectable Error
0423
(400001A7)
Information
[Address Type 3 ] An error was detected in Logical Drive and
corrected.
RO
MA
Logical Drive Corrected
Error
Warning
Information
[Address Type 3 ] Background Initialization failed.
[Address Type 3 ] Background Initialization was stopped.
R
RO
R
6
Event ID
Severity
Description
Log
Alert
Summary
RO
M
Logical Drive Warning
RO
MA
Logical Drive Fatal
Deal Method
(hex digit)
0424
(800001A8)
Warning
0425
(C00001A9)
Fatal
0426
(400001AA)
0427
(400001AB)
0428
(400001AC)
0429
(400001AD)
0430
(400001AE)
0431
(400001AF)
0432
(400001B0)
0433
(400001B1)
0434
(400001B2)
0435
(400001B3)
0436
(400001B4)
0437
(400001B5)
0501
(400001F5)
0502
(800001F6)
0503
(400001F7)
0504
(400001F8)
0505
(800001F9)
Information
[Address Type 3 ] A Warning Error happened to Logical
Drive. Detail : %1
%1 : Detail Information
[Address Type 3 ] A Fatal Error happened to Logical Drive.
Detail : %1
%1 : Detail information
[Address Type 3 ] Initialization was paused.
Information
[Address Type 3 ] Initialization was resumed.
R
Information
[Address Type 3 ] Initialization was queued.
R
Information
[Address Type 3 ] Consistency Check was paused.
R
Information
[Address Type 3 ] Consistency Check was resumed.
R
Information
[Address Type 3 ] Consistency Check was queued.
R
Information
[Address Type 3 ] Background Initialization was paused.
R
Information
[Address Type 3 ] Background Initialization was resumed.
R
Information
[Address Type 3 ] Background Initialization was queued.
R
Information
RO
Information
[Address Type 3 ] Power Save Mode of Logical Drive was
changed.
[Address Type 3 ] SSD Cache Drive was created.
RO
M
SSD Cache Drive Created
Information
[Address Type 3 ] SSD Cache Drive Capacity was changed.
RO
M
SSD Cache Drive Capacity None
Changed
Information
[Address Type 1 ] Battery was detected.
MA
Battery Disconnect
Battery Temperature
Normal
Battery Temperature High
Warning
[Address Type 1 ] Battery was disconnected.
R
None
R
RO
Information
[Address Type 1 ] Battery was replaced.
Information
[Address Type 1 ] The temperature of Battery is normal.
RO
M
[Address Type 1 ] The temperature of Battery is high.
RO
M
Warning
The RAID Controller and/or the Physical Device may
have some kind of problem. You need to ask it which
component has broken.
The RAID Controller and/or the Physical Device may
have some kind of problem. You need to ask it which
component has broken.
Please check the Battery. If some kind of problem
happen to the Battery repeatedly, please replace it.
R
7
Please check the Battery. If some kind of problem
happens to the Battery repeatedly, please replace it.
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
(hex digit)
0506
(800001FA)
0507
(800001FB)
0508
(800001FC)
0509
(400001FD)
0510
(800001FE)
0601
(80000259)
Warning
[Address Type 1 ] The voltage of Battery is low.
RO
M
Battery Voltage Low
Warning
[Address Type 1 ] A Fatal Error happened to Battery.
RO
MA
Battery Fatal
Please check the Battery. If some kind of problem
happens to the Battery repeatedly, please replace it.
Please replace the Battery.
Warning
[Address Type 1 ] The Battery state is unstable.
RO
[Address Type 1 ] The voltage of Battery is normal.
RO
M
Battery Voltage Normal
None
Warning
[Address Type 1 ] Battery Refresh required.
RO
M
Battery Refresh Required
Please start the Battery Refreshing.
Warning
[Address Type 4 ] A Warning Error happened to Enclosure.
RO
M
Enclosure Warning
[Address Type 4 ] A Fatal Error happened to Enclosure.
RO
MA
Enclosure Fatal
[Address Type 4 ] The temperature of Enclosure is Warning
level.
RO
MA
Enclosure Temperature
Warning
[Address Type 4 ] The temperature of Enclosure is Fatal
level.
RO
MA
Enclosure Temperature
Fatal
Please check the Enclosure. If some kind of problem
happens to the Enclosure repeatedly, please deal with
the problem of the Enclosure.
Please check the Enclosure. If some kind of problem
happens to the Enclosure repeatedly, please deal with
the problem of the Enclosure.
Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
Please check the Power Supply Unit of the Enclosure. If
some kind of problem happens to the Power Supply
Unit, please deal with the problem.
Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
None
Information
0602
(C000025A)
Fatal
0603
(8000025B)
Warning
0604
(C000025C)
Fatal
0605
(8000025D)
Warning
[Address Type 5 ] An error happened to the Power Supply
Unit of Enclosure.
RO
MA
Enclosure Power Supply
Unit Error
0606
(8000025E)
Warning
[Address Type 6 ] An error happened to the Fan Unit of
Enclosure.
RO
MA
Enclosure Fan Unit Error
0607
(4000025F)
0701
(400002BD)
Information
[Address Type 4 ] The temperature of Enclosure is Normal
level.
[Address Type 1 ] The Configuration was cleared.
RO
MA
RO
M
Enclosure Temperature
Normal
Configuration Cleared
Information
8
None
Event ID
Severity
Description
Log
Alert
Summary
Deal Method
(hex digit)
0702
(400002BE)
0801
(C0000321)
Information
raidsrv Configuration
O
[CTRL:%1(ID=%2)] Vendor Product Firmware Version
[LD:%3(ID=%4)] RAID:RAIDlevel PD:X,Y,Z (count of LD
STS:Status
[PD:%5(ID=%6] Vendor/Model Firmware Version STS:Status
PWR:Power Status
Fatal
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
%5 : Number of Physical Device
%6 : ID of Physical Device
X, Y, Z : Number of Physical Device used in Logical Drive.
There is not the STS of PD when the device type is not HDD
or HDD(SSD).
It became unable to manage the RAID System due to a fatal
error on the operating system.
RO
*1 : This item may not include in log message by the type of RAID Controller
9
MA
Operating System Fatal
Error
Please solve the fatal error on operating system. This
event is reported by insufficient free memory space,
insufficient free disk space or any other causes. Please
refer Universal RAID Utility User's Guide for detail.