NEC Express5800/R120e-1M User's Guide

Add to my manuals
138 Pages

advertisement

NEC Express5800/R120e-1M User's Guide | Manualzz
NEC Express Server
Express5800 Series
Express5800/R120e-1M
EXP291
User’s Guide
Model Number: N8100-2073F
Chapter 1
General Description
Chapter 2
Preparations
Chapter 3
Setup
Chapter 4
Appendix
10.102.01-101.01
July 2013, First Edition
© NEC Corporation 2013
Documents Provided with This Product
Documents Provided with This Product
Documents for this product are provided as accompanying booklets (
within EXPRESSBUILDER DVD ( ).
) and as electronic manuals (
PDF
) stored
Precautions for Use
Describes points of caution to ensure the safe use of this server.
Read these cautions before using this server.
Getting Started
Describes how to use this server, from unpacking to operations.
Refer to this guide as you begin for an overview of this server.
EXPRESSBUILDER
PDF
User’s Guide
Chapter 1: General Description
Chapter 2: Preparations
Chapter 3: Setting Up Your Server
Chapter 4: Appendix
PDF
PDF
Installation of additional options, connection of peripheral devices,
and ideal location for this server
System BIOS configurations and summary of EXPRESSBUILDER
Specifications and other information
Installation Guide (Windows)
Chapter 1: Installing Windows
Installation of Windows and drivers, and important information for
installation
Chapter 2: Installing the Bundled
Software
Installation of bundled software, such as NEC ESMPRO and
Universal RAID Utility
Maintenance Guide
Chapter 1: Maintenance
Chapter 2: Convenient Features
Chapter 3: Appendix
PDF
Overviews, names, and functions of the server’s parts
Server maintenance and troubleshooting
Useful features and the detail of system BIOS settings, RAID
Configuration Utility, and EXPRESSBUILDER
Error messages and Windows Event Logs
Other documents
Provides the detail of NEC ESMPRO, Universal RAID Utility, and the other features.
2
Express5800/R120e-1M
User’s Guide
Contents
Contents
Documents Provided with This Product ................................................................................................................. 2
Contents ................................................................................................................................................................ 3
Notations Used in This Document ......................................................................................................................... 5
Notations used in the text.............................................................................................................................. 5
Optical disk drives ......................................................................................................................................... 5
Hard disk drives ............................................................................................................................................ 5
Removable media ......................................................................................................................................... 5
Abbreviations of Operating Systems (Windows) ........................................................................................... 5
Trademarks ........................................................................................................................................................... 5
License Agreement Notice..................................................................................................................................... 5
Regulatory Notices ................................................................................................................................................ 5
Warnings and Additions to This Document ............................................................................................................ 5
Latest editions ............................................................................................................................................... 5
Precautions for Use (Be Sure to Read)...................................................................................................... 5
Safety precautions ........................................................................................................................................ 5
Symbols used in this document and on warning labels................................................................................. 5
Safety notes .................................................................................................................................................. 5
General ............................................................................................................................................. 5
Rack installation................................................................................................................................. 5
Power supply and power cord use..................................................................................................... 5
Installation, relocation, storage, and connection ................................................................................ 5
Cleaning and working with internal devices ....................................................................................... 5
During operation ................................................................................................................................ 5
Warning labels .............................................................................................................................................. 5
External view ..................................................................................................................................... 5
Handling precautions (for proper operations)................................................................................................ 5
Chapter 1 General Description............................................................................................................................ 5
1.
Introduction ................................................................................................................................................... 5
2.
Accessories................................................................................................................................................... 5
3.
Features........................................................................................................................................................ 5
3.1 Management Features....................................................................................................................... 5
3.2 Firmware and Software Version Management ................................................................................... 5
4.
Names and Functions of Parts ...................................................................................................................... 5
4.1 Front View (With Front Bezel) ............................................................................................................ 5
4.2 Front View (Without Front Bezel) ....................................................................................................... 5
4.3 Rear View .......................................................................................................................................... 5
4.4 External View..................................................................................................................................... 5
4.5 Internal View ...................................................................................................................................... 5
4.6 Motherboard ...................................................................................................................................... 5
4.7 Status Indicators ................................................................................................................................ 5
4.7.1
4.7.2
4.7.3
POWER LED (
) ............................................................................................................ 5
STATUS LED ( )............................................................................................................... 5
LINK/ACT LED ( 1,
2,
3,
4) ............................................................................. 5
4.7.4
DISK Access LED (
) ...................................................................................................... 5
Express5800/R120e-1M
User’s Guide
3
Contents
4.7.5
4.7.6
4.7.7
4.7.8
4.7.9
Optical Disk Drive Access LED ............................................................................................ 5
UID LED (ID)........................................................................................................................ 5
LED on a hard disk drive ..................................................................................................... 5
LEDs for LAN connectors .................................................................................................... 5
AC POWER LED on Power Unit.......................................................................................... 5
Chapter 2 Preparations ..................................................................................................................................... 46
1.
4
Installing Internal Optional Devices ............................................................................................................. 47
1.1 Safety Precautions........................................................................................................................... 47
1.2 Anti-static Measures ........................................................................................................................ 48
1.3 Overview of Installation and Removal.............................................................................................. 49
1.4 Confirming Servers (UID Switch) ..................................................................................................... 51
1.5 Removing Front Bezel ..................................................................................................................... 52
1.6 Removing Top Cover ....................................................................................................................... 53
1.7 Internal Flash Memory ..................................................................................................................... 54
1.7.1
Installation.......................................................................................................................... 54
1.7.2
Removal ............................................................................................................................ 54
1.8 TPM Kit ............................................................................................................................................ 55
1.8.1
Installation.......................................................................................................................... 55
1.9 Processor......................................................................................................................................... 56
1.9.1
Maximum number of processor cores supported by this server......................................... 56
1.9.2
Installation.......................................................................................................................... 57
1.9.3
Replacement / Removal .................................................................................................... 61
1.10 DIMM ............................................................................................................................................... 63
1.10.1 Maximum supported memory size ..................................................................................... 63
1.10.2 Memory Clock.................................................................................................................... 64
1.10.3 Memory RAS Feature ........................................................................................................ 66
1.10.4 DIMM installation order ...................................................................................................... 67
1.10.5 Installation.......................................................................................................................... 69
1.10.6 Removal / Replacement .................................................................................................... 70
1.10.7 Using Memory RAS Feature .............................................................................................. 71
1.11 Extra Battery / Flash Backup Unit for RAID Controller ..................................................................... 79
1.11.1 Handling precautions ......................................................................................................... 79
1.11.2 Installing Battery (N8103-153/162) .................................................................................... 79
1.11.3 Removal ............................................................................................................................ 81
1.11.4 Installing FBU .................................................................................................................... 81
1.11.5 Removing FBU .................................................................................................................. 83
1.12 LAN Riser Card................................................................................................................................ 84
1.12.1 Installation.......................................................................................................................... 84
1.12.2 Removal ............................................................................................................................ 85
1.13 PCI Card .......................................................................................................................................... 86
1.13.1 Notes ................................................................................................................................. 86
1.13.2 Supported boards and available slots ................................................................................ 87
1.13.3 Installation.......................................................................................................................... 90
1.13.4 Removal ............................................................................................................................ 91
1.13.5 Installing RAID Controller................................................................................................... 92
1.14 Additional HDD Cage....................................................................................................................... 94
1.14.1 Installation.......................................................................................................................... 94
1.14.2 Removal ............................................................................................................................ 95
1.15 Optical Disk Drive ............................................................................................................................ 96
1.15.1 Installation.......................................................................................................................... 96
1.15.2 Removal ............................................................................................................................ 97
1.16 Use of Internal Hard Disk Drives in the RAID System ..................................................................... 98
1.16.1 Connecting cables ............................................................................................................. 99
1.16.2 Notes on Building RAID System ...................................................................................... 100
1.17 Installing Top Cover ....................................................................................................................... 101
1.18 Hard Disk Drive.............................................................................................................................. 102
1.18.1 Installation........................................................................................................................ 103
1.18.2 Removal .......................................................................................................................... 104
1.18.3 Replacing a hard disk drive in the RAID System (Auto Rebuild) ..................................... 105
1.19 Power Supply Unit ......................................................................................................................... 106
1.19.1 Cold Redundant Feature ................................................................................................. 106
1.19.2 Installation........................................................................................................................ 107
1.19.3 Replacing a failing power supply unit............................................................................... 109
Express5800/R120e-1M
User’s Guide
Contents
1.20 Installing Front Bezel ..................................................................................................................... 110
2.
Installation and Connection ....................................................................................................................... 111
2.1 Installation...................................................................................................................................... 111
2.1.1
Installing Rack ................................................................................................................. 111
2.1.2
Installing the server to the rack or removing it from the rack ........................................... 113
2.2 Connection..................................................................................................................................... 118
2.2.1
Connecting to Uninterruptible Power Supply (UPS)......................................................... 120
Chapter 3
Setup.............................................................................................................................................. 121
1.
Turning on the Server................................................................................................................................ 122
1.1 POST ............................................................................................................................................. 123
1.1.1
POST sequence .............................................................................................................. 123
1.1.2
POST error messages ..................................................................................................... 124
2.
BIOS Setup Utility (SETUP) ...................................................................................................................... 125
2.1 Overview........................................................................................................................................ 125
2.2 Starting and Exiting SETUP Utility ................................................................................................. 125
2.2.1
Starting SETUP................................................................................................................ 125
2.2.2
Exiting SETUP ................................................................................................................. 125
2.3 Description on On-Screen Items and Key Usage .......................................................................... 126
2.4 Cases that Require Configuration.................................................................................................. 128
3.
EXPRESSSCOPE Engine 3 ..................................................................................................................... 130
3.1 Overview........................................................................................................................................ 130
3.2 EXPRESSSCOPE Engine 3 Network Configuration...................................................................... 130
4.
EXPRESSBUILDER.................................................................................................................................. 132
4.1 Features of EXPRESSBUILDER ................................................................................................... 132
4.2 Starting EXPRESSBUILDER ......................................................................................................... 132
5.
Installing Software Components................................................................................................................ 133
6.
Turning Off the Server............................................................................................................................... 134
Chapter 4
Appendix ........................................................................................................................................ 135
1.
Specifications ............................................................................................................................................ 136
2.
Interrupt Lines ........................................................................................................................................... 138
Express5800/R120e-1M
User’s Guide
5
Notations Used in This Document
Notations Used in This Document
Notations used in the text
In addition to safety-related symbols urging caution, 3 other types of notations are used in this document. These
notations have the following meanings.
Important
Indicates critical items that must be followed when handling the server or operating software. If
the procedures described are not followed, server failure, data loss, and other serious
malfunctions could occur.
Note
Indicates items that must be confirmed when handling the server or operating software.
Tips
Indicates information that is helpful to keep in mind when using this server.
Optical disk drives
This server is equipped with one of the following drives, depending on the order at the time of purchase. These
drives are referred to as optical disk drives in this document.
• DVD-ROM drive
• DVD Super MULTI drive
Hard disk drives
Unless otherwise stated, hard disk drives (HDD) described in this document refer to both of the following.
• Hard disk drives (HDD)
• Solid state drive (SSD)
Removable media
Unless otherwise stated, removable media described in this document refer to both of the following.
• USB memory
• Flash FDD
6
Express5800/R120e-1M
User’s Guide
Notations Used in This Document
Abbreviations of Operating Systems (Windows)
Windows Operating Systems are referred to as follows.
Refer to Chapter 1 (1.2 Supported Windows OS) in Installation Guide (Windows) for detailed information.
Notations in this document
Official names of Windows
Widnows Server 2012 Standard
Windows Server 2012
Widnows Server 2012 Datacenter
Windows Server 2008 R2 Standard
Windows Server 2008 R2
Windows Server 2008 R2 Enterprise
Windows Server 2008 Standard
Windows Server 2008
*
Windows Server 2008 Enterprise
*
Includes 64-bit and 32-bit Editions unless otherwise stated.
The following appears on EXPRESSBUILDER.
•
•
Windows Server 2008 64-bit Edition:
Windows Server 2008 32-bit Edition:
Express5800/R120e-1M
Windows Server 2008 x64
Windows Server 2008 x86
User’s Guide
7
Trademarks
Trademarks
EXPRESSSCOPE is a registered trademark of NEC Corporation.
Microsoft, Windows, Windows Server, Windows Vista, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation
in the United States and other countries. Intel, Pentium, and Xeon are registered trademarks of Intel Corporation of the United States.
AT is a registered trademark of International Business Machines Corporation of the United States and other countries. Adaptec, its
logo, and SCSI Select are registered trademarks or trademarks of Adaptec, Inc. of the United States. LSI and the LSI logo design are
trademarks or registered trademarks of LSI Corporation. Adobe, the Adobe logo, and Acrobat are trademarks of Adobe Systems
Incorporated. DLT and DLTtape are trademarks of Quantum Corporation of the United States. PCI Express is a trademark of
Peripheral Component Interconnect Special Interest Group. Linux is a trademark or registered trademark of Linus Torvalds in Japan
and other countries. Red Hat® and Red Hat Enterprise Linux are trademarks or registered trademarks of Red Hat, Inc. in the United
States and other countries.
All other product, brand, or trade names used in this publication are the trademarks or registered trademarks of their respective
trademark owners.
8
Express5800/R120e-1M
User’s Guide
License Agreement Notice
License Agreement Notice
Open source software of following license is included in the part of this product (system BIOS).
EDK FROM TIANOCORE.ORG
BSD License from Intel
Copyright (c) 2004, Intel Corporation
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the
following conditions are met:
・
・
・
Redistributions of source code must retain the above copyright notice, this list of conditions and the following
disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Intel Corporation nor the names of its contributors may be used to endorse or
promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY
EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT
SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED
TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY
WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Copyright (c) 2004 - 2007, Intel Corporation
All rights reserved. This program and the accompanying materials are licensed and made available under the
terms and conditions of the BSD License which accompanies this distribution. The full text of the license may be
found at http://opensource.org/licenses/bsd-license.php
THE PROGRAM IS DISTRIBUTED UNDER THE BSD LICENSE ON AN "AS IS" BASIS, WITHOUT
WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED.
Express5800/R120e-1M
User’s Guide
9
Regulatory Notices
Regulatory Notices
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Industry Canada Class A Emission Compliance Statement
This Class A digital apparatus complies with Canadian ICES-003.
Avis de conformité à la réglementation d'Industrie Canada
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
CE / Australia and New Zealand Statement
This is a Class A product. In domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures (EN55022).
BSMI Statement
Turkish RoHS information relevant for Turkish market
EEE Yönetmeliğine Uygundur.
Disposing of your used product
In the European Union
EU-wide legislation as implemented in each Member State requires that used electrical and
electronic products carrying the mark (left) must be disposed of separately from normal household
waste. This includes Information and Communication Technology (ICT) equipment or electrical
accessories, such as cables or DVDs.
When disposing of used products, you should comply with applicable legislation or agreements
you may have. The mark on the electrical and electronic products only applies to the current
European Union Member States.
Outside the European Union
If you wish to dispose of used electrical and electronic products outside the European Union,
please contact your local authority and ask for the correct method of disposal.
10
Express5800/R120e-1M
User’s Guide
Regulatory Notices
KC Statement
Keep in mind the KC Class A Statement when you use the product.
기 종 별
A 급 기기
(업무용 방송통신기기)
사 용 자 안 내 문
이 기기는 업무용(A 급)으로 전자파적합등록을 한 기기이오니
판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의
지역에서 사용하는 것을 목적으로 합니다.
CCC Statement
Keep in mind the CCC Class A Statement when you use the product.
声
明
此为A 级产品,在生活环境中,该产品可能会造成无线电干扰。在这种情况下,
可能需要用户对其干扰采取切实可行的措施。
Vietnam RoHS
Vietnam RoHS information relevant for Vietnam market
Complying with "CIRCULAR, No.30/2011/TT-BCT (Hanoi, August 10 2011),
Temporary regulations on content limit for certain hazardous substances in
electrical products"
Vietnam RoHS
English
Declaration of Conformity
with the requirements of Technical Regulation on the Restriction Of the use of certain
Hazardous Substances in Electrical and Electronic Equipment
(adopted by Order №1057 of Cabinet of Ministers of Ukraine)
The Product is in conformity with the requirements of Technical Regulation on the Restriction
Of the use of certain Hazardous Substances in electrical and electronic equipment (TR on
RoHS).
1.
2.
3.
4.
5.
6.
The content of hazardous substance with the exemption
of the applications listed in the Annex №2 of TR on RoHS:
Lead (Pb) – not over 0,1wt % or 1000wt ppm;
Cadmium (Cd) – not over 0,01wt % or 100wt ppm;
Mercury (Hg) – not over 0,1wt % or 1000wt ppm;
Hexavalent chromium (Cr6+) – not over 0,1wt % or 1000wt ppm;
Polybrominated biphenyls (PBBs) – not over 0,1wt % or 1000wt ppm;
Polybrominated diphenyl ethers (PBDEs) – not over 0,1wt % or 1000wt ppm.
Express5800/R120e-1M
User’s Guide
11
Regulatory Notices
Ukrainian
Декларація про Відповідність
Вимогам Технічного Регламенту Обмеження Використання деяких Небезпечних
Речовин в електричному та електронному обладнанні
(затвердженого Постановою №1057 Кабінету Міністрів України)
Виріб відповідає вимогам Технічного Регламенту Обмеження Використання деяких
Небезпечних Речовин в електричному та електронному обладнанні (ТР ОВНР).
Вміст небезпечних речовин у випадках, не обумовлених в Додатку №2 ТР ОВНР, :
1. свинець(Pb) – не перевищує 0,1 % ваги речовини або в концентрації до 1000
частин на мільйон;
2. кадмій (Cd)– не перевищує 0,01 % ваги речовини або в концентрації до 100
частин на мільйон;
3. ртуть(Hg) – не перевищує 0,1 % ваги речовини або в концентрації до 1000
частин на мільйон;
4. шестивалентний хром (Cr6+ ) – не перевищує 0,1 % ваги речовини або в
концентрації до 1000 частин на мільйон;
5. полібромбіфеноли (PBB) – не перевищує 0,1% ваги речовини або в концентрації
до 1000 частин на мільйон;
6. полібромдефенілові ефіри (PBDE) – не перевищує 0,1 % ваги речовини або в
концентрації до 1000 частин на мільйон.
Russian
Декларация о Соответствии
Требованиям Технического Регламента об Ограничении Использования некоторых
Вредных Веществ в электрическом и электронном оборудовании
(утверждённого Постановлением №1057 Кабинета Министров Украины)
Изделие соответствует требованиям Технического Регламента об Ограничении
Использования некоторых Вредных Веществ в электрическом и электронном
оборудовании (ТР ОИВВ).
Содержание вредных веществ в случаях, не предусмотренных Дополнением №2 ТР
ОИВВ:
1. свинец (Pb) – не превышает 0,1 % веса вещества или в концентрации до 1000
миллионных частей;
2. кадмий (Cd) – не превышает 0,01 % веса вещества или в концентрации до 100
миллионных частей;
3. ртуть (Hg) – не превышает 0,1 % веса вещества или в концентрации до 1000
миллионных частей;
4. шестивалентный хром (Cr6+)– не превышает 0,1 % веса вещества или в
концентрации до 1000 миллионных частей;
5. полибромбифенолы (PBB) – не превышает 0,1 % веса вещества или в
концентрации до 1000 миллионных частей;
6. полибромдифеноловые эфиры (PBDE) – не превышает 0,1 % веса вещества
или в концентрации до 1000 миллионных частей.
12
Express5800/R120e-1M
User’s Guide
Warnings and Additions to This Document
Warnings and Additions to This Document
1.
Unauthorized reproduction of the contents of this document, in part or in its entirety, is
prohibited.
2.
The contents of this document may change without prior notice.
3.
Do not make copies or alter the document content without permission from NEC Corporation.
4.
Every effort has been made to ensure the completeness of this document. However, if you
have any concerns, or discover errors or omissions, please contact your retailer.
5.
Regardless of these 4 items, NEC Corporation does not take responsibility for effects resulting
from operations.
6.
The sample values used in this document are not the actual values.
Keep this document nearby so that you may refer to it as necessary.
Latest editions
This document was created based on the information available at the time of its creation. The screen images,
messages, and procedures may differ from the actual screens, messages, and procedures. Substitute as
appropriate when content has been modified.
The most recent version of User’s Guide, as well as other related documents, is also available for download
from the following website.
http://www.nec.com/
Express5800/R120e-1M
User’s Guide
13
Precautions for Use (Be Sure to Read)
Precautions for Use (Be Sure to Read)
The following provides information required to use your server safely and properly. For details of names in this
section, refer to Names and Functions of Parts in this document.
Safety precautions
Follow the instructions in this document for the safe use of NEC Express server.
This User’s Guide describes hazardous parts of the server, possible hazards, and how to avoid them. Server
components with possible danger are indicated with a warning label placed on or around them (or, in some
cases, by printing the warnings on the server).
In User’s Guide or on warning labels, WARNING or CAUTION is used to indicate a degree of danger. These
terms are defined as follows:
WARNING
Indicates there is a risk of death or serious personal injury
CAUTION
Indicates there is a risk of burns, other personal injury, or property damage
Precautions and notices against hazards are presented with one of the following three symbols. The individual
symbols are defined as follows:
Attention
This symbol indicates the presence of a hazard if
the instruction is ignored.
An image in the symbol illustrates the hazard type.
(Example)
(Electric shock risk)
Prohibited
Action
This symbol indicates prohibited actions. An image (Example)
in the symbol illustrates a particular prohibited
action.
(Do not disassemble)
Mandatory
Action
This symbol indicates mandatory actions. An
image in the symbol illustrates a mandatory action
to avoid a particular hazard.
(Example)
(Disconnect a plug)
14
Express5800/R120e-1M
User’s Guide
Precautions for Use (Be Sure to Read)
(A label example used in this User’s Guide)
Symbol to draw
attention
Description of a warning
Term indicating a degree of danger
WARNING
Use only the specified outlet
Use a grounded outlet with the specified voltage. Use of an improper power source
may cause a fire or a power leak.
Symbols used in this document and on warning labels
Attentions
Indicates the presence of electric shock
hazards.
Indicates the presence of mechanical
parts that can result in bodily injury.
Indicates the presence of a hot surface
or component. Touching this surface
could result in bodily injury.
Indicates the presence of mechanical
parts that can result in pinching or other
bodily injury.
Indicates there is a risk of explosion.
Indicates the presence of laser beam
that cause blindness.
Indicates there is a risk of fire or fumes.
Indicates a general notice or warning
that cannot be specifically identified.
Prohibited Actions
Do not disassemble, repair, or modify
the server. Otherwise, an electric shock
or fire may be caused.
Do not touch the server with wet hand.
Otherwise, an electric shock may be
caused.
Do not touch the component specified
by this symbol. Otherwise, an electric
shock or burn may be caused.
Do not use the server in the place where
water or liquid may pour. Otherwise, an
electric shock or fire may be caused.
Do not place the server near the fire.
Otherwise, a fire may be caused.
Indicates a general prohibited action
that cannot be specifically identified.
Mandatory Actions
Unplug the power cord of the server.
Otherwise, an electric shock or fire may
be caused.
Indicates a mandatory action that
cannot be specifically identified. Make
sure to follow the instruction.
Make sure equipment is properly
grounded. Otherwise, an electric shock
or fire may be caused.
Express5800/R120e-1M
User’s Guide
15
Precautions for Use (Be Sure to Read)
Safety notes
This section provides notes on using the server safely. Read this section carefully to ensure proper and safe use
of the server. For symbols, refer to Safety precautions.
General
WARNING
Do not use the server for services where human life may be at stake or high reliability is required.
This server is not intended for use in medical, nuclear, aerospace, mass transit or other applications where
human life may be at stake or high reliability is required, nor is it intended for use in controlling such
applications. We disclaim liability for any personal injury and property damages caused by such use of this
server.
Do not use the server if any smoke, odor, or noise is present.
If smoke, odor, or noise is present, immediately turn off the server and disconnect the power plug from the
outlet, then contact the store where you purchased the product or your maintenance service company.
Using the server in such conditions may cause a fire.
Do not insert needles or metal objects.
Do not insert needles or metal objects into ventilation holes in the server or openings in the optical disk
drive. Doing so may cause an electric shock.
Use a rack that conforms to the designated standard
This server can be mounted onto a 19-inch rack that conforms to EIA standards. Do not mount the server
onto any rack that does not conform to EIA standards. Doing so may cause a server malfunction, personal
injury, or damage to peripheral devices. For more information about racks that can be used with the
server, consult with your maintenance service company.
Use the server only under the specified environment
Do not install the server rack in any environment that is not suitable for installation.
Installation in an unsuitable environment is harmful for the server and other systems installed in the rack
and may cause fire or personal injury due to the rack falling. For a detailed explanation on installation
environments or seismic reinforcement, consult with the instruction manual supplied with the rack or your
maintenance service company.
CAUTION
Keep water or foreign matter away from the server.
Do not let any liquid such as water or foreign materials including pins or paper clips enter the server.
Failure to follow this warning may cause an electric shock, a fire, or failure of the server. When such things
accidentally enter the server, immediately turn off the power and disconnect the power plug from the
outlet. Do not disassemble the server, and contact the store where you purchased the product or your
maintenance service company.
16
Express5800/R120e-1M
User’s Guide
Precautions for Use (Be Sure to Read)
Rack installation
CAUTION
Do not attempt to carry or install the server alone
More than two people are required to carry or install the rack. Otherwise, the rack may fall, resulting in
personal injury or damage to peripheral devices. In particular, tall racks such as a 44U rack become
unstable unless steadied with a stabilizer. Make sure that two or more people hold the rack to carry or
install the rack.
Do not install with the load weight distributed unevenly
To avoid unevenly distributing the load of the rack and server, install a stabilizer or connect multiple racks
to distribute the weight. Otherwise, the rack may fall, resulting in personal injury.
Do not install components alone, and check the door hinge pins of the rack
Two or more people are required to install the rack components such as the door or rails. When installing
the door, make sure that both upper and lower hinge pins are held in place. Incomplete attachment may
cause components to fall off as well as personal injury.
Do not extend any device from the rack that is not stabilized
When extending a device from the rack, make sure that the rack is stable (by using a stabilizer or seismic
reinforcement). Otherwise, the rack may fall, resulting in personal injury.
Do not extend more than one device out of the rack
Extending multiple devices from the rack may cause the rack to fall, resulting in personal injury. Extend
only one device at one time.
Do not exceed the rated capacity of the power supply when connecting devices
To prevent burn injuries, fire, and damage to the server, make sure the load on the branch circuit that
supplies power to the rack will not exceed the rated load. For inquiries regarding the installation or wiring of
the power supply system, consult with the company that performed the installation or wiring, or the power
company that services your area.
Express5800/R120e-1M
User’s Guide
17
Precautions for Use (Be Sure to Read)
Power supply and power cord use
WARNING
Do not hold the power plug with a wet hand.
Do not disconnect/connect the plug while your hands are wet. Failure to follow this warning may cause an
electric shock.
Do not connect the ground wire to a gas pipe.
Never connect the ground wire to a gas pipe. Failure to follow this warning may cause a gas explosion.
CAUTION
Plug in to a proper power source.
Use a grounded outlet with the specified voltage. Use of an outlet with a voltage other than that specified
causes fire and electrical leakage. Do not install the server in any environment that requires an extension
cord. Connecting to a cord that does not conform to the power supply specs of the server causes
overheating, resulting in fire.
If you want to use an AC cord set with a ground wire of class 0I, be sure to connect the ground wire before
inserting the power plug into the outlet. Before disconnecting the ground wire, be sure to disconnect the
power plug from the output.
Do not connect many cords into a single outlet by using extension cords.
The electric current exceeding the rated flow overheats the outlet, which may cause a fire.
Insert the power plug into the outlet as far as it goes.
Heat generation resulting from a halfway inserted power plug (imperfect contact) may cause a fire. Heat
will also be generated if condensation is formed on dusty blades of the halfway inserted plug, increasing
the possibility of fire.
Do not use any unauthorized interface cable.
Use only the interface cables provided with the server. Electric current that exceeds the amount allowed
could cause fire. Also, observe the following precautions to prevent electrical shock or fire caused by a
damaged power cord.
• Do not stretch the cord harness
• Do not pinch the power cord
• Do not bend the power cord.
• Keep chemicals away from the power cord
• Do not twist the power cord
• Do not place any object on the power cord
• Do not step on the power cord.
• Do not alter, modify, or repair the power cord
• Uncoil the power cord before use
• Do not use a damaged power cord (replace the
• Do not secure the power cord with staples or
equivalents
damaged power cord with a power cord of the
same standard. For information on replacing the
power cord, contact the store where you
purchased the product or a maintenance service
company)
18
Express5800/R120e-1M
User’s Guide
Precautions for Use (Be Sure to Read)
CAUTION
Do not use the attached power cord for any other devices or usage.
The power cord that comes with your server is designed aiming to connect with this server and to use with
the server, and its safety has been tested. Do not use the attached power cord for any other purpose.
Doing so may cause a fire or an electric shock.
Do not pull out a cable by gripping the cable part.
Pull a cable straight out by gripping the connector part. Pulling a cable by gripping the cable part or
applying extra pressure to the connector part may damage the cable part, which may cause a fire or
electric shock.
Installation, relocation, storage, and connection
CAUTION
Do not attempt to lift the server by yourself
Some servers weigh up to 31 kg depending on the server components. Carrying the server by yourself
may damage your back. At least two people should securely hold the server from the bottom when
carrying it. Do not attempt to lift the server while the front bezel attached. Doing so causes the front bezel
to fall off the server, resulting in personal injury.
Do not install the server in any place other than specified.
Do not install the server in the following places or any place other than specified in this User's Guide.
Failure to follow this instruction may cause a fire.
• A dusty place
• A humid place such as near a boiler
• A place exposed to direct sunlight
• An unstable place
Do not use the server in an environment where corrosive gas is present
Do not install the server in a place subject to corrosive gases including sodium chloride, sulfur dioxide,
hydrogen sulfide, nitrogen dioxide, chlorine, ammonia, or ozone. Do not install the server in an
environment that contains dust, chemicals that accelerate corrosion such as NaCl or sulfur, or conductive
materials. Failure to follow this warning may cause the wiring on the printed wiring board to short-circuit,
leading to fire. If you have any questions, contact the store where you purchased the product or a
maintenance service company.
Do not install the server while the cover is removed
Do not install the server to a rack while the cover or other relevant items removed. Not only will the cooling
effect within the server decrease, causing the server to malfunction, but also may allow dust to enter the
server, resulting in fire or electrical shock.
Do not get your fingers caught in the rails
When mounting/removing the server onto/from the rack, be careful to avoid getting your fingers caught in
the rails or cutting your fingers on the rails.
Express5800/R120e-1M
User’s Guide
19
Precautions for Use (Be Sure to Read)
CAUTION
Do not apply any weight on the server when it is extended from the rack
Do not apply force on the server when it is extended from the rack. Doing so cause the frames to bend,
which makes it impossible to be mounted on the rack. It also may cause the server to fall, resulting in
personal injury.
Do not attempt to connect or disconnect the interface cable while the power cord is plugged into
an outlet
Be sure to unplug the power cord from a power outlet before connecting/disconnecting any interface cable
to/from the server. If the server is off-powered but its power cord is plugged to a power source, touching a
cable or connector may cause an electric shock or a fire resulted from a short circuit.
Use only the specified interface cable.
Use only interface cables provided by NEC and locate a proper device and connector before connecting a
cable. Using an authorized cable or connecting a cable to an improper destination may cause a short
circuit, resulting in a fire.
Also, observe the following notes on using and connecting an interface cable.
• Do not use any damaged cable connector.
• Do not step on the cable.
• Do not place any object on the cable.
• Do not use the server with loose cable connections.
Do not use any damaged cable.
Cleaning and working with internal devices
WARNING
Do not disassemble, repair, or alter the server.
Never attempt to disassemble, repair, or alter the server on any occasion except as described in this
document. Failure to follow this warning may cause not only malfunction of the server but also an electric
shock or fire.
Do not attempt to remove lithium, NiMH, or Li-ion batteries.
The server contains the lithium, NiMH, or Li-ion battery (some optional devices have a lithium, NiMH, or
Li-ion battery installed). Do not remove the battery. Placing a battery close to a fire or in the water may
cause an explosion.
When the server does not operate appropriately due to the dead battery, contact the store you purchased
the product or your maintenance service company. Do not attempt to disassemble the server to replace or
recharge the battery by yourself.
Disconnect the power plug before cleaning the server.
Be to power off the server and disconnect the power plug from a power outlet before cleaning or
installing/removing internal optional devices. Touching any internal device of the server with its power cord
connected to a power source may cause an electric shock even of the server is off-powered.
Occasionally disconnect the power plug from the outlet and clean the plug with a dry cloth. Heat will be
generated if condensation is formed on a dusty plug, which may cause a fire.
20
Express5800/R120e-1M
User’s Guide
Precautions for Use (Be Sure to Read)
CAUTION
High temperature
Components including internal hard disk drives in the server are extremely hot just after the server is
turned off. Allow the surface to cool before installing/removing.
Secure cables or cards in place
Be sure to secure the power cord, interface cables, and cards in place. Incomplete installation causes a
loose connection, resulting in smoke or fire
Electric shock
The cooling fans, hard disk drives, and power supply unit (only when two servers are installed) support hot
swapping. If replacing a component when the electrical current is being supplied, use extreme caution not
to get electric shock by touching terminal parts of the internal components.
During operation
CAUTION
Do not pull out or remove the server from the rack.
Do not pull the server out of the rack or remove it from the rack. In addition to causing equipment to not
function properly, separating the server from the rack may result in personal injury.
Avoid contact with the server during thunderstorms.
Do not touch any part of the server including the cables when a thunderstorm is approaching. Also, do not
connect or disconnect any devices. There may be a risk of electric shock from lightning strike.
Keep animals away from the server.
Keep animals such as pets away from the server. Pet hair or other waste enters the server, which may
cause a fire or electric shock.
Do not leave the optical disk drive tray open.
Dust may get in the server when the tray is open, which may result in a malfunction. In addition, bumping
the open tray could cause personal injury.
Do not remove the server from the rack while it is operating.
Do not pull out or remove the server from the rack while the server is running. In addition to causing
equipment to not function properly, separating the server from the rack may result in personal injury.
Do not place any object on top of servers.
Separating the server from the rack may result in personal injury and damage to nearby personal
belongings.
Do not get yourself caught in the fan
Keep your hands and hair away from the cooling fan at the rear of the server during operation. Failure to
observe this warning may cause your hands or hair to catch in the fan, resulting in personal injury.
Express5800/R120e-1M
User’s Guide
21
Precautions for Use (Be Sure to Read)
Warning labels
Warning label are attached on or near the components with potential hazards (This label is either attached or
printed on the component.) to draw attention from users to potential hazards involved in handling the server. (Do
not remove or black out this label and keep it clean). If no label is attached or printed on the server, or if there is
a label coming off or stained, contact your sales representative.
External view
22
Express5800/R120e-1M
User’s Guide
Precautions for Use (Be Sure to Read)
Handling precautions (for proper operations)
Be sure to observe the following precautions for the proper functioning of the server. Ignoring the precautions
may cause server malfunction or failure.
•
Do not use any cell phone or PHS and switch off them near the server. Electric waves from such
devices can cause server to malfunction.
•
Install the server in an appropriate place. For details about the installation location, refer to Chapter
2 Preparations (2. Installation and Connection).
•
Before connecting/removing cables to/from peripheral devices, make sure that the server is off and
unplug the power cord, if they are non plug-and-play devices.
•
Connect the provided power cord to a 100/200 VAC outlet.
•
Make sure that the access LED on the server is off before turning off the power or ejecting an optical
disk.
•
Wait for at least 30 seconds before connecting power cord to power outlet after disconnecting it.
•
If any Uninterruptible Power Supply unit is connected, set it to wait for at least 30 seconds before
turning on the server after power off.
•
Do not press the POWER switch to turn on the server before the POWER LED (amber) is unlit.
•
Wait for at least 30 seconds before turning on the server after turning off the server.
•
Turn off the server and unplug the power cord before moving it.
•
Regularly clean the server to prevent various types of failure. (Refer to Chapter 1 Maintenance (2.
Daily Maintenance) in "Maintenance Guide" for details about cleaning.)
•
Momentary voltage drop may occur due to lightning strike. To prevent this, use of UPS is
recommended.
•
We do not guarantee that any copy-protected CD that does not conform to standards will play on the
server’s optical disk drive.
•
In the following cases, check and adjust the system clock before operation.
− After transportation
− After storage
− After the server is used following a period of disuse, in which storage conditions did not conform to those
that guarantee server operations (temperature: see the table below; humidity: 20% to 80%).
N code
Operation
guarantee
temperature
N8101675F
676F
677F
678F
679F
680F
10 to 40°C
681F
682F
683F
684F
685F
686F
10 to 35°C
•
Check the system clock approximately once per month. Use of a time server (NTP server) is
recommended if high accuracy timing is required by the system.
•
Observe the storage conditions (Temperature: −10°C to 55°C, Humidity: 20% to 80%, No
condensation of moisture) to store the server.
•
Do not power off or reset the server, nor disconnect the power cord before POST completes.
•
If this server, internal optional devices, and media set for the backup devices (tape cartridges) are
moved from a cold place to a warm place in a short time, condensation will occur and cause
malfunctions and failures when these are used in such state. To protect important stored data and
property, make sure to wait for a sufficient period to use the server and components in the operating
environment.
Reference: Time effective at avoiding condensation in winter (more than 10°C differences between the
room temperature and atmospheric temperature)
Disk devices: Approximately 2 to 3 hours
Tape media: Approximately 1 day
•
For optional devices, we recommend you use our NEC products. Even if they are successfully
installed or connected, installation of unsupported devices can cause the server to malfunction or
even failure. You will be charged to repair failure or damage caused by use of such products even
within warranty period.
Express5800/R120e-1M
User’s Guide
23
Precautions for Use (Be Sure to Read)
Tips for your health and safety
Using a computer extensively may affect different parts of your body. Here are tips you should follow while working on
a computer to minimize strain on your body.
Keep proper posture
The basic body position for using a computer is sitting straight with
your hands on the keyboard parallel with the floor, and your eyes
directed slightly downward toward the monitor. With the proper
posture described above, no unnecessary strain is applied on any
part of your body, in other words when your muscles are most
relaxed.
Working on the computer with bad posture such as hunching over or
being too close to the monitor could cause fatigue or deteriorated
eyesight.
Adjust the angle of your display
Most display units are designed for adjustment of the horizontal and
vertical angles. This adjustment is important to prevent the screen
from reflecting bright lights and to make the display contents easy to
see. Working without adjusting the display to a comfortable angle
makes it difficult for you to maintain a proper posture and you will
get tired easily. Adjust the viewing angle before use.
Adjust the brightness and contrast of the display
Display screens have functions to control brightness and contrast.
The most suitable brightness/contrast depends on age, individuals,
and environment, so adjust it to suit your preferences. A too bright
or too dark display is bad for your eyes.
Adjust the angle of keyboard
Some keyboards are ergonomically designed, which allow the angle
to be adjusted. Adjusting the angle of the keyboard is effective to
reduce tension on your shoulders, arms, and fingers.
Clean your equipment
Keeping your equipment clean is important not only for the appearance but also for functional and safety reasons. A
dusty monitor makes it difficult to see the display contents, so clean it regularly.
Take rest breaks
When you feel tired, take a break. Light exercise is also
recommended.
24
Express5800/R120e-1M
User’s Guide
NEC Express5800 Series
Express5800/R120e-1M
General Description
This chapter introduces the features of this server and the name of each part.
1. Introduction
2. Accessories
Verify the condition of your server's accessories.
3. Standard Features
This section describes the server’s features and the server management.
4. Names and Functions of Parts
This section describes the name of each part contained in this server.
Express5800/R120e-1M
User’s Guide
25
Chapter 1 General Description
1.
1. Introduction
Introduction
Thank you for purchasing this NEC Express5800 Series product.
This high performance server is powered by the latest microprocessor "Intel® Xeon® processor.
NEC’s latest technology and architectures realize high-power and high-speed operation that cannot be matched
by existing servers.
The server is designed with consideration of not only reliability but also expandability, which enables you to use
it as a network server.
Read this document before using the server thoroughly to fully understand handling of Express5800 Series
Server and appreciate its functions to the maximum extent.
26
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
2.
2. Accessories
Accessories
The carton box contains various accessories which are required for setup or maintenance. Make sure you
have them all for future use.
•
Front Bezel
•
Bezel Lock Key (attached to Front Bezel)
•
Slide Rails
•
EXPRESSBUILDER
•
SAS/SATA cable (RAID controller is unmounted)
•
Getting Started
*1
*1 Instruction manuals are stored in EXPRESSBUILDER. Adobe Reader is required to read or print them.
Make sure you have all accessories and inspect them. If an accessory is missing or damaged, contact your
sales representative.
Important
The chassis serial number plate and maintenance label is located on the
server. If the serial number does not match the number on the warranty, you
may not be guaranteed against failure even within the warranty period.
Contact your sales representative if they do not match.
Express5800/R120e-1M
User’s Guide
27
Chapter 1 General Description
3.
3. Features
Features
The server has the following features:
High performance
•
Intel® Xeon® processor
– N8101-675F: E5-2609 v2(2.50GHz 4 Core)
– N8101-676F: E5-2620 v2(2.10GHz 6 Core)
– N8101-677F: E5-2630 v2(2.60GHz 6 Core)
– N8101-678F: E5-2630L v2(2.40GHz 6 Core)
– N8101-679F: E5-2637 v2(3.50GHz 4 Core)
– N8101-680F: E5-2640 v2(2GHz 8 Core)
– N8101-681F: E5-2650 v2(2.60GHz 8 Core)
– N8101-682F: E5-2660 v2(2.20GHz 10 Core)
– N8101-683F: E5-2670 v2(2.50GHz 10 Core)
– N8101-684F: E5-2690 v2(3GHz 10 Core)
– N8101-685F: E5-2697 v2(2.70GHz 12 Core)
– N8101-686F: E5-2695 v2(2.40GHz 12 Core)
•
Turbo Boost Technology feature
•
Hyper Threading Technology feature *1
•
High-speed memory access (DDR3L 1600 / 1866 supported) *2
•
High-speed disk access (SATA/SAS 6Gbps supported)
•
High-speed 1000BASE-T/100BASE-TX/10BASE-T (2 ports) interface (1Gbps/100Mbps/10Mbps supported)
High reliability
28
•
Processor throttle-ring feature
•
Memory monitoring feature (error correction/error detection)
•
Memory degeneracy feature (logical isolation of a failed device)
•
Memory x4 SDDC feature
•
Memory mirroring, memory LockStep (x8 SDDC), memory sparing features
•
Memory throttle-ring feature
•
Bus parity error detection
•
Temperature detection
•
Error detection
•
Internal fan monitoring feature
•
Internal voltage monitoring feature
•
Power redundant feature (hot swapping supported)
•
RAID System (Disk Array) (An option card is required.)
•
Auto rebuild feature (hot swapping supported)
•
BIOS password feature
•
The security lock that comes with Front Bezel
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
3. Features
Management Utilities
•
NEC ESMPRO
•
ExpressUpdate
•
Remote controlling feature (EXPRESSSCOPE Engine 3)
•
RAID System management utility (Universal RAID Utility)
•
Hard disk drive monitoring
•
Power supply monitoring
Power saving and noiseless design
•
Selection of power unit appropriate to environment, work load, and configuration
•
Power consumption monitoring feature
•
Power control feature
•
80 PLUS® Platinum certified high efficiency power supply
•
Fan control appropriate to environment, work load, and configuration
•
Silent sound design
•
Enhanced Intel SpeedStep® Technology supported
Expandability
•
PCI Express 3.0 (x16 lanes): 1 slot (Full height)
•
PCI Express 3.0 (x8 lanes): 1 slot (Low profile)
•
PCI Express 3.0 (x8 lanes): 1 slot (dedicated to RAID Controller)
•
PCI Express 3.0 (x8 lanes): 1 slot (dedicated to LAN Riser card)
•
Large capacity memory of up to 1.5 TB *3
•
Can upgrade to multi-processor system with up to two processors
•
Expansion Bay (for hard disk drives): 8 slots *4
•
Optical disk drive bay provided as standard *5
•
USB2.0 interface (Front: 2 ports, rear: 4 ports, internal: 2 ports)
•
Three LAN ports (one for management LAN)
•
With optional LAN riser card, two ports can be added.
Ready to use
•
No cable connection is required to install a hard disk drive and additional power supply unit (hot swap
supported).
Many built-in Features
•
Redundant power supply system supported (valid when optional power supply unit is installed)
•
El Torito Bootable CD-ROM (no emulation mode) format supported
•
Software power-off
•
Remote power-on feature
•
AC-Link feature
•
Remote console feature
•
Power switch mask
•
Connector for display unit provided on front panel
•
Baseboard Management Controller (BMC) conforming to IPMI v2.0
Express5800/R120e-1M
User’s Guide
29
Chapter 1 General Description
3. Features
Self-diagnosis
•
Power On Self-Test (POST)
•
Test and Diagnosis (T&D) utility
Easy setup
•
EXPRESSBUILDER (setup utility)
•
BIOS Setup utility (SETUP)
Maintenance features
•
Off-line Tools
•
Memory dump feature using DUMP Switch
•
Feature to back up and restore BIOS/BMC settings using EXPRESSSCOPE Profile Key
®
*1: Unsupported on Xeon processor E5-2609 v2 embedded models.
*2: Processor core speed depends on processor type, number and type of DIMMs installed, and operating
voltage (1.35/1.5 V).
*3: In 2-CPU configuration. Up to 768 GB in 1-CPU configuration.
*4: With N8154-41 additional HDD cage installed. Six slots in standard configuration
*5: Cannot be installed when N8154-41 additional HDD cage is installed.
30
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
3. Features
3.1 Management Features
The hardware components of the server provide operation control/reliability features as shown below.
Additionally, NEC ESMPRO Agent, which is provided in EXPRESSBUILDER, enables you to collectively
manage the state of your systems. You can also monitor the server states from a PC to manage the network
where NEC ESMPRO Manager provided in EXPRESSBUILDER is installed.
The features available on this server are as shown in the table below.
Function
Availability
Hardware
Description
Shows physical hardware information.
Memory bank
{
Shows physical memory information.
Device info
{
Shows information specific to the server.
CPU
{
Shows physical CPU information.
{
Shows logical CPU information and monitors the load factor.
System
Shows logical memory information and monitors the status.
{
I/O device
Shows information on I/O devices (serial ports, keyboard, mouse, and
video).
System
environment
Monitors temperatures, fans, voltage, power supply, and others.
Temperature
{
Monitors the temperature inside of the chassis.
Fan
{
Monitors the fans.
Voltage
{
Monitors the voltage inside of the chassis.
Power supply
{
Monitors the power supply unit.
Software
{
Shows service, driver, and OS information.
Network
{
Shows network (LAN) information and monitors packets.
BIOS
{
Shows BIOS information.
Local polling
{
Monitors the values of MIB items obtained by NEC ESMPRO Agent.
Storage
{
Monitors controllers and storage devices including hard disk drives.
File system
{
Shows the file system configuration and monitors the free space.
RAID System
{
Monitors the following RAID Controllers:
Others*
{
Monitors OS stall using the Watch Dog Timer.
{
Performs alert processing after an OS STOP error occurs.
• Optional RAID Controller (N8103-149/150/151/160)
{: Supported. U: Partially supported. ×: Unsupported.
*: Not displayed on the NEC ESMPRO Manager screen.
Tips
NEC ESMPRO Manager and NEC ESMPRO Agent are supplied with the server as
standard. For how to install and use each software component, refer to the
explanation of the component.
Express5800/R120e-1M
User’s Guide
31
Chapter 1 General Description
3. Features
3.2 Firmware and Software Version Management
Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and
software as well as update them by applying update packages.
This feature automatically updates modules without stopping the system just by specifying the updating
packages from NEC ESMPRO Manager.
32
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4.
4. Names and Functions of Parts
Names and Functions of Parts
This section describes the names of the server parts.
4.1 Front View (With Front Bezel)
(3)-1
(3)-2
(3)-3
(3)-4
(4)
(6)
1
3
2
4
(7)
(5)
(1)
(2)
(1) Front Bezel
(5) STATUS LED
The cover to protect the front of the server. This cover can
be locked with the provided Bezel Lock Key.
This LED indicates the server status. (See page 5.)
(6) Unit ID (UID) LED
(2) Key Slot
This LED turns on when UID Switch is pressed. Commands
The slot for Bezel Lock Key that is used to lock Front Bezel.
from the software also cause it to turn on or flash.
(See page 5.)
(3) LINK/ACT LED
This LED turns on when the server is connected to the
(7) POWER LED
network. (See page 5.)
This LED indicates power status of server. (See page 5.)
(3)-1: LAN connector 1
(3)-2: LAN connector 2
(3)-3: LAN connector 3
(3)-4: LAN connector 4
LEDs for LAN3 and LAN4 are lit when optional LAN riser
card is installed.
(4) Disk Access LED
This LED indicates status of internal hard disk drive.
(See page 5.)
Express5800/R120e-1M
User’s Guide
33
Chapter 1 General Description
4. Names and Functions of Parts
4.2 Front View (Without Front Bezel)
See (3) to (5) on previous
page.
(8) Hard disk drive bay
(16) POWER Switch/LED
The bay where HDD are installed. The sequential numbers
The switch to turn the server on and off. Press once to turn
indicate the corresponding slot numbers. All bays include
on the server. POWER LED lights when it is on. Press it
Dummy Trays.
again to turn off the server. Hold down the switch for 4
seconds or longer to forcibly turn off the server.
(9) DISK LED
(See page 5.)
The LED provided for each HDD.
This LED indicates hard disk drive status. (See page 5.)
(17) Display connector
Connect a display unit. This connector is exclusively used
(10) Pull-out Tab
with the display connector on rear panel.
A label indicating the part number and serial number of the
server is located on Pull-out Tab.
(18) Optical disk drive bay
Bay to install an optical disk drive.
(11) USB connectors (front)
These connectors are used to connect devices that support
Either of the following drive can be installed.
the USB interface.
– DVD-ROM drive
– DVD SuperMULTI drive
(12) BMC RESET Switch
The switch to reset BMC of this server. Use the switch only
(19) 2.5-inch HDD cage bay
when there is a problem with EXPRESSSCOPE Engine 3
Bay to install an optional HDD cage N8154-41.
(BMC).
This bay is exclusively used with an optical disk drive.
To use this switch, press it at least five seconds.
(13) RESET switch
Press this switch to reset the server.
(14) DUMP Switch (NMI)
When DUMP Switch is pressed, memory dump is
performed.
(15) Unit ID (UID) Switch/LED
The switch to turn on and off UID LED.
Pressing the switch once turns on UID LED and pressing
again turns off the LED.
Commands from the software also cause it to turn on or
flash. (See page 5.)
34
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4. Names and Functions of Parts
4.3 Rear View
(1) Power unit (Power supply slot 1)
(11) SPEED LED
The power unit supplies DC power to the server.
The LED indicates the transfer speed of LAN ports.
(See page 5.)
(2) AC Inlet
This socket is used to connect the power cord.
(12) Management LAN connector
A LAN connector which supports 100BASE-TX/10BASE-T.
(3) AC POWER LED
This port cannot be used as a data transmission port.
The LED indicates power supply status. (See page 5.)
This port is used for connecting to EXPRESSSCOPE
(4) Thumb nut
Engine 3.
Used to secure the top cover.
(13) Serial port A (COM) connector
(5) Slot for full-height PCI card
Slot to install a full-height PCI card. Assigned PCI slot
This connector is used to connect devices that support a
number is "1B".
serial interface. Note that it is not possible to directly
connect to a leased line.
(6) Slot for low-profile PCI card
Slot to install a low-profile PCI card. Assigned PCI slot
(14) Display connector
The connector to connect a display unit.
number is "1C".
This connector is exclusively used with the display
(7) Blank cover (for additional power unit)
connector on front panel.
Remove this cover to install an optional power unit.
(15) DUMP Switch (NMI)
(8) USB connectors
When DUMP Switch is pressed, memory dump is
These connectors are used to connect devices that support
performed.
the USB interface.
(16) UID Switch/LED
(9) LINK/ACT LED
The switch to turn on and off UID LED.
The LED indicates the access status of LAN. (See page 5.)
Pressing the switch once turns on UID LED and pressing
(10) LAN connectors
again turns off the LED.
1000BASE-T/100BASE-TX/10BASE-T supported network
Commands from the software also cause it to turn on or
connectors
flash. (See page .5)
(10)-1: LAN port connector 1
(17) POWER LED
(10)-2: LAN port connector 2
This LED indicates power supply status. (See page 5.)
If Shared BMC LAN feature is enabled in ROM Utility, LAN
connector 1 can also be used as the management LAN
(18) Blank cover (for LAN riser card)
port. Sharing port is not recommended from the point of
Remove this cover to install an optional LAN riser card.
performance and security.
Express5800/R120e-1M
User’s Guide
35
Chapter 1 General Description
4. Names and Functions of Parts
4.4 External View
(1) Top Cover
(2) Release Button.
36
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4. Names and Functions of Parts
4.5 Internal View
(4)
(2)
(5)
(6)
(7)
(3)-1
(3)-2
(3)-3
(8)
(3)-4
(3)-5
(3)-6
(3)-7
(3)-8
(9)
(1)
(1)
(11)
(10)
Front Panel Board
(5) DIMM (optional)
(2)
Backplane
(6) Support bar
(3)
Cooling Fan
(7) Motherboard
-1
FAN1F/R
(8) PCI Riser Card
-2
FAN2F/R
-3
FAN3F/R
-4
FAN4F/R
-5
FAN5F/R
-6
FAN6F/R (optional)
-7
FAN7F/R (optional)
-8
FAN8F/R (optional)
(9) Slot dedicated to RAID Controller
Assigned PCI slot number if "1A".
(10) Power Supply Unit
(11) Battery tray for RAID Controller
FAN1 to FAN5 are factory installed. FAN6 to FAN8 are
required in 2-CPU configuration.
(4)
Processor (Optional)
Express5800/R120e-1M
User’s Guide
37
Chapter 1 General Description
4. Names and Functions of Parts
4.6 Motherboard
(11)
(3)
(4)
(5)
(6)
(7)
(8)-2
(12)
(9) (10) (13) (14) (15) (14) (16) (17)
(2)
(5)
(1)-1
(18)
(19)
(5)
(20)
(21)
(23)
(22)
(24)
(2)
(1)-2
(2)
(8)-1 (27) (5)
38
Express5800/R120e-1M
(26)
User’s Guide
(25) (5)
(13)
Chapter 1 General Description
(1)
4. Names and Functions of Parts
(16) Connector for option COM
Processor (CPU) socket
-1: Processor #1 (CPU #1)
Connect an additional RS-232C connector kit N8117-01A
-2: Processor #2 (CPU #2)
to use this port as a serial port.
(17) SPI Flash Mezzanine connector
(2)
DIMM socket
(3)
DC connector
(4)
SATA connector (for optical disk drive)
(5)
Unused connector
(6)
Front Panel connector
(7)
Fan connector
(8)
Power connector
-1: Standard power unit (POW #1)
-2: Optional power unit (POW #2)
(9)
EXPRESSSCOPE Profile Key (SPI flash memory) has
been installed, where BIOS and BMC configuration data is
stored. Relocate it when replacing motherboard to inherit
configuration data.
(18) Front video connector
(19) TPM kit connector
(20) SATA connector (for optical disk drive)
(21) PCI Riser Card connector (dedicated to low profile
cards)
LAN riser card connector
For the supported card specifications, refer to Chapter 2
(10) Lithium battery
(11) Clear CMOS Jumper switch
(1.11 PCI card).
(22) PCI Riser Card connector (dedicated to full height
(12) Clear Password Jumper switch
cards)
(13) Unused connector
For the supported card specifications, refer to Chapter 2
(14) USB memory module connector
(1.11 PCI card).
(15) HDD BP connector
(23) SATA connector
(24) Connectors for external devices
(25) Internal Flash Memory connector
(26) RAID Controller connector
(27) USB connector (front)
Express5800/R120e-1M
User’s Guide
39
Chapter 1 General Description
4. Names and Functions of Parts
4.7 Status Indicators
This section explains the indication and meanings of the server LEDs.
4.7.1
POWER LED (
)
POWER LED indicates power ON/OFF status of the server.
The following table lists POWER LED patterns.
POWER LED pattern
On (green)
On (amber)
Description
The server is normally powered on.
BMC is being initialized.
When the power cord is connected, the LED goes on amber for 40 seconds.
The server can be powered on after the amber LED is unlit.
Do not power on the server while the LED is lit amber.
Off
The server is off-powered.
The server is in halt status.
40
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4.7.2
STATUS LED (
4. Names and Functions of Parts
)
While hardware is operating normally, STATUS LED lights green. STATUS LED is off or lights/flashes
amber if there is a hardware failure.
The following table lists STATUS LED patterns.
Tips
Once you have installed NEC ESMPRO, you can reference error logs to check the
causes of failures.
STATUS LED
Description
Solution
pattern
On (green)
The server is operating normally.
Flashing (green)
Memory is in a degraded state
A
correctable
memory
error
−
Identify the device in degraded state by using BIOS
has
occurred.
often Setup Utility (SETUP), and replace it as soon as
possible.
Operating while CPU error is detected.
In redundant power configuration, power is not
supplied to either of power unit.
Off
The power is off.
Turn on the server.
POST is in progress.
Wait for a while. STATUS LED will turn green after
POST completes.
Watchdog timer expired.
Turn the power off and then turn it on.
If POST screen displays any error message, take notes
of the message, and contact your sales representative.
Memory dump is being requested.
Wait until the memory dump is completed.
(e.g. when DUMP Switch is pressed)
Note: It remains green if the dump is caused
by software.
On (amber)
A temperature alarm was detected.
Check the internal fan for dusts. Also check if the fan
unit is properly connected.
If the LED indication does not change, contact your
sales representative.
A CPU error occurred.
Turn the power off and then turn it on.
Abnormal CPU temperature is detected.
If POST screen displays any error message, take notes
A PCI system error occurred
of the message, and contact your sales representative.
A PCI parity error occurred
A PCI bus error occurred.
A voltage alarm was detected.
Contact your sales representative.
Fan error was detected.
Sensor error was detected.
A CPU temperature alarm was detected.
An error occurred on Intel® Node Manager
(one of the features of EXPRESSSCOPE
Engine 3).
Flashing (amber)
Power Supply Unit is broken.
A fan alarm was detected.
Contact your sales representative.
Check if the internal fan cable is properly connected.
If the LED indication does not change, contact your
sales representative.
A temperature warning was detected.
Check the internal fan for dusts. Also check if the fan
unit is properly connected.
If the LED indication does not change, contact your
sales representative.
A voltage warning was detected
Contact your sales representative.
One or more hard disk drives are broken.
Express5800/R120e-1M
User’s Guide
41
Chapter 1 General Description
4.7.3
4. Names and Functions of Parts
LINK/ACT LED (
1,
2,
3,
4)
LINK/ACT LED on front panel indicates the status of LAN port.
LEDs
3 and
4 turns on, off, or flashes when an optional LAN riser card is installed.
The following table lists LINK/ACT LED patterns.
LINK/ACT LED pattern
4.7.4
Description
On (green)
The server is connected with network normally.
Flashing (green)
The server is accessing network.
Off
The server is disconnected from network.
DISK Access LED (
)
DISK Access LED indicates the status of HDDs.
The following table lists DISK Access LED patterns.
DISK Access LED pattern
Description
On (green)
Hard disk drive is being accessed.
On (amber)
Hard disk drive is failing.
Solution
–
Contact your sales representative.
(only when RAID system is
configured)
Flashing green and amber
Rebuild is in progress.
–
Hard disk drive is halted.
–
alternately.
(only when RAID system is
configured)
Off
4.7.5
Optical Disk Drive Access LED
The LED for optical disk drive at the front of the server flashes when a CD or DVD is being accessed.
4.7.6
UID LED (ID)
UID LED is provided one each at the front and rear of the server. If you press UID Switch provided at the
front or rear of the server, the light turns on. If you press it again, the light turns off. It flashes when
commands from software are received. This LED is used to identify the target server among multiple servers
installed in a rack. Especially when performing maintenance from behind the server, lighting the LED will
help you to identify which server to work with.
The following table lists UID LED patterns.
UID LED pattern
On (blue)
The UID switch is pressed.
Off
The UID switch is not pressed.
Tips
42
Description
You can turn on an LED using remote management software.
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4.7.7
4. Names and Functions of Parts
LED on a hard disk drive
Each HDD is equipped with DISK LED.
DISK LED
The following table lists DISK LED patterns.
DISK LED pattern
Description
On (green)
Hard disk drive is being accessed.
On (amber)
Hard disk drive is failing.
Solution
–
Contact your sales representative.
(only when RAID system
is configured)
Flashing green and amber Rebuild is in progress.
–
alternately.
When the failed hard disk drive is replaced,
(only when RAID system
rebuild process starts automatically (auto rebuild
is configured)
feature).
Off
Hard disk drive is halted.
Important
–
Observe the following precautions whenever you use the auto rebuild
feature.
• Do not turn off or reboot the server while a HDD is being rebuilt.
• Wait at least 90 seconds before installing a HDD after removing one.
• Do not replace a HDD while another HDD is being rebuilt.
Express5800/R120e-1M
User’s Guide
43
Chapter 1 General Description
4.7.8
4. Names and Functions of Parts
LEDs for LAN connectors
Three LAN connectors provided at the rear of the server have two LEDs each.
LINK/ACT SPEED
LED
LED
LINK/ACT SPEED
LED
LED
LINK/ACT SPEED
LED
LED
LAN connector Management LAN
for data
connector
transmission
•
LINK/ACT LED (
1,
2,
M)
This LED indicates the state of the LAN port.
The following table lists LINK/ACT LED patterns.
LINK/ACT LED pattern
•
Description
On (green)
The server is connected with network normally.
Flashing (green)
The server is accessing network.
Off
The server is disconnected from network.
SPEED LED (
1,
2,
M)
This LED indicates which network interface is used.
− Two onboard LANs ( 1,
2) support 1000BASE-T, 100BASE-TX, and 10BASE-T.
− Management LAN ( M) supports 100BASE-TX and 10BASE-T.
The following table lists LINK/ACT LED patterns.
SPEED LED pattern
44
Description
On (amber)
The port is operating with 1000BASE-T interface.
On (green)
The port is operating with 100BASE-TX interface.
Off
The port is operating with 10BASE-T interface.
Express5800/R120e-1M
User’s Guide
Chapter 1 General Description
4.7.9
4. Names and Functions of Parts
AC POWER LED on Power Unit
The power unit is equipped with AC POWER LED.
AC POWER LED
Standard power unit
The following table lists LINK/ACT LED patterns.
AC POWER LED pattern
Description
Solution
On (green)
The server is powered on.
–
Flashing (green)
The power cable is connected and AC power is
–
supplied.
Cold Redundant feature is enabled.
–
(See page 97.)
On (amber)
The power cable is not connected in redundant
Connect the power cable.
power configuration.
Power unit is failing.
Flashing (amber)
Contact your sales representative.
Power unit is failing.
Express5800/R120e-1M
User’s Guide
45
NEC Express5800 Series
Express5800/R120e-1M
Preparations
This chapter describes preparations for using this server.
1. Installing Internal Optional Devices
You can skip this section if you did not purchase any optional devices.
2. Location and Connection
Place the server in a suitable location and connect some cables following this section.
46
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.
1. Installing Internal Optional Devices
Installing Internal Optional Devices
This section describes the instructions for installing supported optional devices and precautions. If you did not
purchase any optional device requiring installation, you may skip this section.
Important
Use only the devices and cables specified by NEC. You will be charged to
repair damages, malfunctions, and failures caused by the use of any devices
or cables not specified for use with this server even within the warranty
period.
1.1
Safety Precautions
Be sure to observe the following precautions to install and remove optional devices properly and safely.
WARNING
Be sure to observe the following precautions to use the server safety. Failure
to observe the precautions may cause death or serious injury. For details, refer
to Safety precautions in Precautions for Use.
• Do not disassemble, repair, or modify the server.
• Do not remove the lithium battery, NiMH battery, or Li-ion battery.
• Disconnect the power plug when installing and removing devices.
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Do not drop
• Do not leave the server being pulled out.
• Make sure to complete installation.
• Do not install with the cover removed.
• Do not get your fingers caught.
• High temperature
• Electrical shock
Express5800/R120e-1M
User’s Guide
47
Chapter 2 Preparations
1.2
1. Installing Internal Optional Devices
Anti-static Measures
The server contains electronic components sensitive to static electricity. Avoid failures caused by static
electricity when installing or removing any optional devices.
This product contains static-sensitive electronic components. Follow this measures below to avoid a
failure caused by static electricity when installing or uninstalling any optional device.
•
Wearing Anti-static Wrist Strap Or Anti-static Gloves
Wear a wrist strap on your wrist and connect the wire to the chassis. If there is no wrist strap,
touch an unpainted metal surface of the chassis connected to the ground to discharge static
electricity from your body before touching the component. Touch the metal part occasionally to
discharge the static electricity while working on the component.
•
Checking the Workplace
−
Work on an anti-static floor or concrete floor.
−
If you work on a place where static electricity is likely to be generated (e.g. carpet), be sure to
provide anti-static protection.
•
Using the Work Table
Place the server on a mat with Electrostatic Discharge (ESD) protection.
•
Clothing
•
−
Do not wear wool or synthetic clothes.
−
Wear anti-static shoes.
−
Remove any kind of metal accessories such as a ring, bracelet or wrist watch.
Handling of Components
−
Keep the component in an anti-static bag until you install it to the server.
−
Hold the component by the edges to avoid touching any terminals or mounting parts.
−
Place the component in an anti-static bag when storing or moving them.
•
Handling of Cables
When connecting a cable (e.g., LAN cable), static electricity may also be charged due to friction
against the floor. Connecting the charged cable with an I/O device may cause damage to the
devices in the system. It is recommended to use a product such as electrostatic discharge kit to
eliminate the static charge before connecting the cable.
•
Installing and Uninstalling the Optional Device
−
To avoid electric hazard and malfunction, be sure to turn off the power switch of the server
and unplug the power cord from the outlet before installing or uninstalling any optional device.
If the device is hot-swappable, you do not need to turn off the power switch and unplug the
power cord.
−
The device contains static-sensitive electronic components. When installing or uninstalling the
optional device, wear an anti-static wrist strap on your wrist to avoid a failure caused by the
static electricity. To use the strap, connect the wire to the chassis.
48
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.3
1. Installing Internal Optional Devices
Overview of Installation and Removal
Install/remove components by using the following procedure.
Installing/removing internal components except for hard disk drives should be done after dismounting the
server from the rack. It is recommended that more than one person removes the server from the rack.
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Do not drop the server
• Do not leave the server pulled out of the rack
• Replace the cover after installing components
• Beware of high temperatures
• Do not get your fingers caught when installing components
1.
If the server is mounted on a rack, use the UID switch to identify the target server.
See Chapter 2 (1.4 Confirming Servers (UID Switch)).
2.
Remove Front Bezel.
See Chapter 2 (1.5 Removing Front Bezel).
3.
If the server is ON, turn it off.
See Chapter 3 (6. Turning Off the Server).
4.
Disconnect the power cord from the outlet and the server.
Important
After disconnecting the power cord from the server, wait for at least 30
seconds before continuing to work because the components on the
motherboard might still be operating for about 30 seconds even after the
power cord was disconnected.
5.
You need to pull out the server from rack and put it on a flat rigid desk when installing or removing the
components other than the following two devices:
See Chapter 2 (2.1 Installation) for details.
Hard disk drive
Power supply unit
Important
Do not leave the server open on the rack.
If you are going to install a hard disk drive only, go to step 10.
6.
Remove Top Cover.
See Chapter 2 (1.6 Removing Top Cover).
7.
Depending on the components to be installed or removed, follow the procedure in order.
See Chapter 2 (1.7 Internal Flash Memory) to (1.16 Use of Internal Hard Disk Drives in the RAID
System).
Express5800/R120e-1M
User’s Guide
49
Chapter 2 Preparations
1. Installing Internal Optional Devices
8.
Attach Top Cover.
See Chapter 2 (1.17 Installing Top Cover).
9.
Mount the server onto the rack.
See Chapter 2 (2.1.2 (1) Installation).
10. Install hard disk drives
See Chapter 2 (1.18 Hard Disk Drive).
11. Install power supply units
See Chapter 2 (1.19 Power Supply Unit).
12. Attach Front Bezel.
See Chapter 2 (1.20 Installing Front Bezel).
This is the end of the installation or removal procedures for internal optional devices.
Continue the setup with reference to Chapter 2 (2.2 Connection).
50
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.4
1. Installing Internal Optional Devices
Confirming Servers (UID Switch)
Using UID (Unit ID) Switch helps you to identify the target server.
When the server is working, before you turn the server off or disconnect a cable from the server, be sure to
identify the target server by using UID Switch first.
To turn UID LED on, press UID Switch. When it is pressed again, the LED will be off.
UID switch / LED
FRONT
REAR
UID switch / LED
Express5800/R120e-1M
User’s Guide
51
Chapter 2 Preparations
1.5
1. Installing Internal Optional Devices
Removing Front Bezel
To remove Front Bezel, follow the steps below.
1.
Insert the attached Bezel Lock Key into the key slot and turn the key to the front bezel side while
pressing it lightly to release the lock.
Unlocked
Unlocked
2.
Pull the Front Bezel toward you to release the tab from the frame and then remove Front Bezel from
the server.
Note
52
Locked
Locked
Be careful not to press POWER Switch.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.6
1. Installing Internal Optional Devices
Removing Top Cover
You need to remove top cover when installing or removing the following component:
Optical disk drive,
LAN riser card,
DIMM,
Processor,
TPM module,
Internal Flash Memory,
Additional HDD cage,
PCI card,
RAID Controller,
Battery for RAID Controller
1.
See steps 1 to 5 in Chapter 2 (1.3 Overview of Installation
and Removal) for preparations.
2.
Loosen thumb nut located on rear panel.
3.
Slide Top Cover toward the rear of the server while pressing
Release Button on the cover.
4.
Lift the cover, and remove it from the server.
Express5800/R120e-1M
User’s Guide
53
Chapter 2 Preparations
1.7
1. Installing Internal Optional Devices
Internal Flash Memory
This section describes the procedure for installing Internal Flash Memory (optional).
Internal Flash Memory
connector
1.7.1
Installation
Install Internal Flash Memory in the following procedure.
1.7.2
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Attach Internal Flash Memory and fix it
with the screw provided with Internal
Flash Memory.
Removal
To remove Internal Flash Memory, reverse the installation procedure.
54
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.8
1. Installing Internal Optional Devices
TPM Kit
This section describes the procedure for installing optional TPM Kit.
Connector for TPM Kit
1.8.1
Installation
Install TPM Kit in the following procedure.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Install TPM Kit and secure it by pushing the nylon rivet provided with TPM Kit.
Note
The TPM kit once installed cannot be removed.
Express5800/R120e-1M
User’s Guide
55
Chapter 2 Preparations
1.9
1. Installing Internal Optional Devices
Processor
You can configure the multi-processor system by adding an optional processor.
Important
• You must avoid static electricity to work with the procedure below. For
details, see Chapter 2 (1.2 Anti-static Measures).
• Make sure to use the processor authorized by NEC. Installing a third-party
processor may cause a failure of the processor as well as the
motherboard. Repair of the server due to failures or damage resulted from
installing such a processor will be charged.
Tips
After adding the processor, Windows may record the event log to System catogory
of Event Viewer, but it is no problem for operation.
1.9.1
Maximum number of processor cores supported by this server
The maximum number of processor cores (logical processors) available on the server depends on the
architecture (x86 architecture) and OS specs.
Maximum number of processor cores
OS
The maximum number of
The maximum number of logical
logical processors
processors supported by this
supported by OS
server
Microsoft Windows Server 2008 Standard
Microsoft Windows Server 2008 Enterprise
32
32
Microsoft Windows Server 2008 Standard (x64)
Microsoft Windows Server 2008 Enterprise (x64)
64
48
Microsoft Windows Server 2008 R2 Standard (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
256
48
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
640 *1
48
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
640 *1
48
*1: Up to 320 when Hyper-V featurre is used.
56
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.9.2
1. Installing Internal Optional Devices
Installation
Follow steps below to install the processor.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Locate the CPU socket to which you are going to install a processor.
3.
Remove the screws that secure the dummy cover, and remove it.
Note
4.
Keep the removed dummy cover for future use.
Remove the protective cover from the CPU socket.
Note
Keep the removed protective cover for future use.
Express5800/R120e-1M
User’s Guide
57
Chapter 2 Preparations
1. Installing Internal Optional Devices
5.
Push down the socket lever marked with "
open the lever until it stops.
→" once to unlatch it from the hook, then slowly
6.
Push down the socket lever marked with "←
the lever until it stops.
" once to unlatch it from the hook, then slowly open
7.
Lift the plate.
Important
8.
Do not touch the socket contacts.
Put the additional processor on the CPU socket slowly and gently.
For easy installation, hold edges of processor with your thumb and index fingers so that the notch is
aligned with the key on the CPU socket.
Notch
Pin mark
Pin mark
Important
Key
• Be sure to hold the processor only at the edges.
• Pay attention not to touch the bottom of the processor (pin section).
Note
• Insert the processor while aligning the notch on the processor with the key on
the CPU socket.
• Bring down the processor straight without tilting or sliding it in the socket.
58
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
9.
1. Installing Internal Optional Devices
Lightly push the processor to the CPU socket, and close the plate.
10. Close the socket lever marked with "←
" to fix it.
11. Close the socket lever marked with "
→" to fix it.
12. Put the heat sink on the processor and fix the heat sink with four screws.
Temporarily tighten the four screws diagonally, then tighten them securely.
Make sure that the screw aligns with the screw hole. If not, the screw may damage the motherboard.
Note
Make sure the location to put the heat sink.
Express5800/R120e-1M
User’s Guide
59
Chapter 2 Preparations
1. Installing Internal Optional Devices
13. Make sure that the heat sink is installed on a level with the motherboard.
REAR
FRONT
Note
• If the heat sink is not level, remove it, and then install it again.
The following probably causes the heat sink not to be level:
– The CPU is not positioned correctly.
– All screws are not completely tightened.
• Do not move the secured heat sink.
14. Install an additional fan unit provided with additional CPU board. Remove fan cover from the slot
where you are going to install an additional fan.
15. Remove a single screw from the tray, and remove the battery tray for RAID Controller.
60
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
16. Pass the cable below the cage, and set the additional fan unit.
17. Connect fan cable securely to HDDBP connector.
18. When the additional fan unit is installed, secure the battery tray for RAID Controller with a single
screw you have removed in Step 15.
19. Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
20. Run BIOS Setup Utility (SETUP) to confirm the following settings. See Chapter 2 (1. Details of System
BIOS) in "Maintenance Guide".
Advanced → Processor Configuration → Processor Information
[CPU ID]
[L2 Cache RAM]
[L3 Cache RAM]
1.9.3
Replacement / Removal
To remove processor (CPU), reverse the installation procedure.
Perform the following steps if using the server with the processor (CPU) being removed.
1. Mount the protective cover to processor (CPU) socket.
2. Secure the dummy cover to the slot with four screws.
3. Remove the additional fan.
4. Mount the fan cover.
Express5800/R120e-1M
User’s Guide
61
Chapter 2 Preparations
1. Installing Internal Optional Devices
Important
• Do not remove any processor unless it is failed.
• To remove the heat sink from the processor, first turn the heat sink to the
left and right lightly to make sure that the heat sink can be apart from the
processor.
Removing the heat sink with it adhering to the processor may cause the
processor and/or CPU socket to be defected.
62
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.10 DIMM
Install a DIMM (Dual Inline Memory Module) to a DIMM socket on the motherboard in the server. The
motherboard provides twenty-four sokets to install DIMMs.
Important
• You must avoid static electricity to work with the procedure below. For
details, see Chapter 2 (1.2 Anti-static Measures).
• Use only the specified DIMMs. Installing a DIMM from a third party may
damage not only the DIMM but the motherboard. You will be charged to
repair failures or damages caused by the use of such products even within
the warranty period.
Tips
Up to 1.5 TB (64 GB x 24) can be installed in 2-CPU configuration. Up to 768 GB
(64 GB x 12) can be installed in 1-CPU configuration. No DIMM is factory installed
in standard configuration.
1.10.1
Maximum supported memory size
The maximum available memory size on the server depends on the architecture and OS specs.
List of maximum memory sizes
The maximum memory
size supported on
each OS
OS
Microsoft Windows Server 2008 Standard
4 GB
The maximum memory size
supported on the server
4 GB (If using HW-DEP feature)
* Default factory settings
About 2 GB (If not using HW-DEP
feature)
Note: If you are not using the HW-DEP
feature, set Execute Disable Bit
(XD Bit) to Disabled in the BIOS
settings.
Windows Server 2008 Standard x64 Edition
Windows Server 2008 R2 Standard x64 Edition
32 GB
32 GB
Windows Server 2008 Enterprise x86 Edition
64 GB
64GB
Microsoft Windows Server 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
2TB
1.5TB
Microsoft Windows Server 2012 Standard *1
Microsoft Windows Server 2012 Datacenter *1
4TB
1.5TB
*1: Up to 1 TB on virtual machine.
Express5800/R120e-1M
User’s Guide
63
Chapter 2 Preparations
1.10.2
1. Installing Internal Optional Devices
Memory Clock
The server supports the memory clock speed of DDRL3-1066/1333/1600MHz. However, the actual memory
clock speed depends on CPU and memory configuration. (The all of DIMMs operate at the same clock speed.)
•
The factory-set memory clock speed is 1.35 V (power-saving mode). You can change this setting in BIOS
SETUP menu.
•
The system operates at 1.5 V of memory clock speed in the configuration listed below (setting of 1.35 V is
not allowed).
Clock speed
Server model
number
Number of DIMMs
Supply
Supply
(per 1 CPU)
voltage
voltage
1.35V
1.5V
Type of DIMMs
(CPU type)
N8101-675F
(E5-2609v2)
N8102-534F 8GB DDR3-1600 UNB Memory Kit
N8102-537F 8GB DDR3-1600 REG Memory Kit
N8102-538F 16GB DDR3-1600 REG Memory Kit
N8102-539F 32GB DDR3-1600 REG Memory Kit
N8102-548 8GB DDR3-1600 REG Memory Kit
N8102-549 16GB DDR3-1600 REG Memory Kit
N8102-550 32GB DDR3-1600 REG Memory Kit
N8102-540F 64GB DDR3-1600 LR Memory Kit
Up to 4 sets
(8 DIMMs)
1333 MHz
1333 MHz
Up to 4 sets
(8 DIMMs)
1333 MHz
1333 MHz
5 sets
(10 DIMMs) or
more
800 MHz
1066 MHz
Up to 4 sets
(8 DIMMs)
1333 MHz
1333 MHz
1066 MHz
1066 MHz
1066 MHz
1066 MHz
5 sets
(10 DIMMs) or
more
-
N8102-541F 128GB DDR3-1333 LR Memory Kit
N8102-545F 16GB DDR3-1866 REG Memory Kit
N8102-546F 32GB DDR3-1866 REG Memory Kit
Up to 2 sets
(4 DIMMs)
-
1333 MHz
N8102-552 12GB DDR3-1600 REG Memory Kit
-
800 MHz
1066 MHz
Up to 4 sets
(8 DIMMs)
1333 MHz
1600 MHz
Up to 4 sets
(8 DIMMs)
1333 MHz
1600 MHz
5 sets
(10 DIMMs) or
more
800 MHz
1066 MHz
Up to 4 sets
(8 DIMMs)
1600 MHz
1600 MHz
1066 MHz
1066 MHz
1066 MHz
1066 MHz
N8102-553 24GB DDR3-1600 REG Memory Kit
N8102-554 48GB DDR3-1600 REG Memory Kit
N8101-676F
(E5-2620v2)
N8102-534F 8GB DDR3-1600 UNB Memory Kit
N8101-677F
N8102-537F 8GB DDR3-1600 REG Memory Kit
(E5-2630v2)
N8102-538F 16GB DDR3-1600 REG Memory Kit
N8101-678F
N8102-539F 32GB DDR3-1600 REG Memory Kit
(E5-2630Lv2)
N8102-548 8GB DDR3-1600 REG Memory Kit
N8102-549 16GB DDR3-1600 REG Memory Kit
N8102-550 32GB DDR3-1600 REG Memory Kit
N8102-540F 64GB DDR3-1600 LR Memory Kit
5 sets
(10 DIMMs) or
more
-
N8102-541F 128GB DDR3-1333 LR Memory Kit
N8102-545F 16GB DDR3-1866 REG Memory Kit
N8102-546F 32GB DDR3-1866 REG Memory Kit
Up to 2 sets
(4 DIMMs)
-
1600 MHz
N8102-552 12GB DDR3-1600 REG Memory Kit
-
N8102-553 24GB DDR3-1600 REG Memory Kit
N8102-554 48GB DDR3-1600 REG Memory Kit
64
Express5800/R120e-1M
User’s Guide
800 MHz
1066 MHz
Chapter 2 Preparations
1. Installing Internal Optional Devices
Clock speed
Server model
number
Number of DIMMs
Supply
Supply
(per 1 CPU)
voltage
voltage
1.35V
1.5V
Type of DIMMs
(CPU type)
N8101-679F
(E5-2637v2)
N8102-534F 8GB DDR3-1600 UNB Memory Kit
N8101-680F
N8102-537F 8GB DDR3-1600 REG Memory Kit
(E5-2640v2)
N8102-538F 16GB DDR3-1600 REG Memory Kit
N8101-681F
N8102-539F 32GB DDR3-1600 REG Memory Kit
(E5-2650v2)
N8102-548 8GB DDR3-1600 REG Memory Kit
N8101-682F
N8102-549 16GB DDR3-1600 REG Memory Kit
(E5-2660v2)
N8102-550 32GB DDR3-1600 REG Memory Kit
N8101-683F
N8102-540F 64GB DDR3-1600 LR Memory Kit
(E5-2670v2)
N8101-684F
Up to 4 sets
(8 DIMMs)
1333 MHz
1600 MHz
Up to 4 sets
(8 DIMMs)
1333 MHz
1600 MHz
5 sets
(10 DIMMs) or
more
800 MHz
1066 MHz
Up to 4 sets
(8 DIMMs)
1600 MHz
1600 MHz
1066 MHz
1066 MHz
1066 MHz
1066 MHz
5 sets
(10 DIMMs) or
more
-
(E5-2690v2)
N8101-686F
(E5-2695v2)
N8102-541F 128GB DDR3-1333 LR Memory Kit
N8101-685F
N8102-545F 16GB DDR3-1866 REG Memory Kit
(E5-2697v2)
N8102-546F 32GB DDR3-1866 REG Memory Kit
Up to 2 sets
(4 DIMMs)
-
1866 MHz
N8102-552 12GB DDR3-1600 REG Memory Kit
-
N8102-553 24GB DDR3-1600 REG Memory Kit
800 MHz
1066 MHz
N8102-554 48GB DDR3-1600 REG Memory Kit
Express5800/R120e-1M
User’s Guide
65
Chapter 2 Preparations
1.10.3
1. Installing Internal Optional Devices
Memory RAS Feature
The server supports the following RAS features. Some restrictions (e.g., DIMM installation location) are
imposed on using the Memory Mirroring or Memory LockStep feature. See Chapter 2 (1.10.7 Using Memory
RAS Feature) for conditions appropriate to your requirements.
•
•
•
•
Standard memory feature (x4 SDDC ECC memory)
Memory Sparing feature
Memory Mirroring feature (restrictions imposed on DIMM configuration)
Memory LockStep feature (x8 SDDC ECC memory) (restrictions imposed on DIMM configuration)
Supported RAS features depend on additiional memory board.
See the table below for RAS features supported by additiional memory board.
List of features supported by additiional memory board
Standard
feature
(x4 SDDC)
Memory
Mirroring
feature
Memory
LockStep
feature
(x8 SDDC)
Memory
Sparing
feature
N8102-534F 8GB DDR3-1600 UNB Memory Kit
{
×
×
×
N8102-537F 8GB DDR3-1600 REG Memory Kit
{
×
×
×
N8102-538F 16GB DDR3-1600 REG Memory Kit
{
×
×
×
N8102-539F 32GB DDR3-1600 REG Memory Kit
{
×
×
×
N8102-540F 64GB DDR3-1600 LR Memory Kit
{
×
×
×
N8102-541F 128GB DDR3-1333 LR Memory Kit
{
×
×
×
N8102-545F 16GB DDR3-1866 REG Memory Kit
{
×
×
×
N8102-546F 32GB DDR3-1866 REG Memory Kit
{
×
×
{
×
N8102-548 8GB DDR3-1600 REG Memory Kit
×
{
N8102-549 16GB DDR3-1600 REG Memory Kit
×
{
{
×
N8102-550 32GB DDR3-1600 REG Memory Kit
×
{
{
N8102-552 12GB DDR3-1600 REG Memory Kit
×
×
×
×
{
N8102-553 24GB DDR3-1600 REG Memory Kit
×
×
×
{
N8102-554 48GB DDR3-1600 REG Memory Kit
×
{
×
×
{
×
×
×
N code
Product name
N8102-582F 4GB DDR3-1600 REG Memory Kit
{: Supported, ×: Not supported
66
Express5800/R120e-1M
User’s Guide
×
Chapter 2 Preparations
1.10.4
1. Installing Internal Optional Devices
DIMM installation order
• DIMM installation order in 1-CPU configuration differs from that in 2-CPU
Note
configuration.
• If CPU2 is not installed, CPU2_DIMM1 to CPU2_DIMM12 are disabled.
• See List of features supported by additiional memory board before using
memory RAS feature.
In 1-CPU configuration, install two DIMMs starting from the smallest slot number.
In 2-CPU configuration, alternately install two DIMMs starting from the smallest slot number of each CPU.
Installation order depends on combination of DIMMs to be installed. See the table below to find allowable
combination of DIMMs, and install DIMMs starting from the largest capacity and from the smallest slot number.
N code
N8102534F
537F
538F
539F
540F
541F
545F
546F
N8102-534F
{
×
{
×
×
×
×
×
{
×
N8102-537F
×
{
×
×
×
×
N8102-538F
×
{
{
{
×
×
×
×
N8102-539F
×
{
{
{
×
×
×
×
N8102-540F
×
×
×
×
{
{
×
×
N8102-541F
×
×
×
×
{
{
N8102-545F
×
×
×
×
×
×
×
{
×
{
N8102-546F
×
×
×
×
×
×
{
{
{: Allowed to be install together.
N code
N8102-548
N8102-549
N8102-550
×: Not allowed to be install together.
N8102549*
{
{
{
548*
{
{
{
550*
{
{
{
{: Allowed to be install together.
×: Not allowed to be install together.
* : Any other combination of DIMMs than described in this table is not allowed.
552*
N8102553*
554*
N8102-552
{
×
×
N8102-553
×
{
×
N8102-554
×
×
{
N code
{: Allowed to be install together.
×: Not allowed to be install together.
* : Any other combination of DIMMs than described in this table is not allowed.
Express5800/R120e-1M
User’s Guide
67
Chapter 2 Preparations
68
1. Installing Internal Optional Devices
1CPU
configuration
2CPU
configuration
2
4
6
2
4
6
3
7
11
3
7
11
CPU1_DIMM 3
CPU1_DIMM 7
CPU1_DIMM 11
CPU1_DIMM 4
CPU1_DIMM 8
CPU1_DIMM 12
5
3
1
5
3
1
9
5
1
9
5
1
4
8
12
4
8
12
CPU1_DIMM 10
CPU1_DIMM 6
CPU1_DIMM 2
CPU1_DIMM 9
CPU1_DIMM 5
CPU1_DIMM 1
CPU2_DIMM 3
CPU2_DIMM 7
CPU2_DIMM 11
CPU2_DIMM 4
CPU2_DIMM 8
CPU2_DIMM 12
10
6
2
10
6
2
CPU2_DIMM 10
CPU2_DIMM 6
CPU2_DIMM 2
CPU2_DIMM 9
CPU2_DIMM 5
CPU2_DIMM 1
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.10.5
1. Installing Internal Optional Devices
Installation
Install a DIMM by using the following procedure.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Open levers on left and right sides of
DIMM slot, and remove the dummy
cover.
Note
3.
Keep the removed dummy cover for future use.
Push the DIMM straight into the socket.
When a DIMM is inserted into the
socket, the lever automatically closes.
Key slot
Key
Important
• Make sure the orientation of the DIMM. The DIMM has a notch, preventing
being incorrectly inserted.
• Do not apply too much pressure when you push a DIMM into the socket.
Doing so can damage the socket or terminal part.
4.
Attach the duct.
5.
Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
6.
Confirm that no error messages are displayed in POST screen.
If any error messages are displayed, see Chapter 3 (1. POST Error Message) in "Maintenance
Guide".
7.
Run BIOS Setup Utility, and select Memory Configuration and then Memory Information from the
Advanced menu. Make sure the capacity of added DIMM is displayed properly.
See Chapter 2 (1. Details of System BIOS) in "Maintenance Guide".
8.
Select Memory Configuration from the Advanced menu, and then specify Yes for Memory Retest.
After that, select Save Changes and Exit to reboot.
9.
Set the size of Paging File to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, see Chapter 1 (7.1 Specifying Memory Dump Settings (Debug Information)) in
"Installation Guide (Windows)".
For other OS, follow the manual of the OS.
Express5800/R120e-1M
User’s Guide
69
Chapter 2 Preparations
1.10.6
1. Installing Internal Optional Devices
Removal / Replacement
To remove DIMM, reverse the installation procedure.
Be sure to install dummy cover to the slots from where DIMMs are removed.
Important
Failing to install dummy cover to vacant slot may cause malfunction of the
server due to insufficient cooling effect.
Note
• When removing a defective DIMM, check error messages displayed at POST or
NEC ESMPRO and check the DIMM socket where the defective DIMM is
installed.
• At least one DIMM needs to be installed for the server to operate.
Take the steps below after replacing or removing DIMMs.
70
1.
Confirm that no error messages are displayed on POST. If any error message is displayed, see Chapter
3 (1. Post Error Message) in "Maintenance Guide".
2.
Run BIOS Setup Utility, select Memory Configuration from the Advanced menu, and then specify Yes
for Memory Retest. After that, select Save Changes and Exit to reboot.
3.
Set the size of Paging File to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, see Chapter 1 (7.1 Specifying Memory Dump Settings (Debug Information)) in
"Installation Guide (Windows)".
For other OS, follow the manual of the OS.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.10.7
1. Installing Internal Optional Devices
Using Memory RAS Feature
This server has RAS feature including Standard Memory feature (x4 SDDC ECC memory), Memory Mirroring
feature, Memory Sparing feature, and Memory Lock Step (x8 SDDC ECC memory) feature. SDDC (Single
Device Correction) allows automatic correction of memory error (multi-bit error).
Note
• See List of features supported by additiional memory board in 1.10.3 Memory
RAS Feature before using memory RAS feature.
• Only the features that additiional memory board support can be used.
The memory area on the motherboard of the server is divided into four memory channels.
Memory controller
Memory controller
Memory Mirroring, Memory Lock Step, and Memory Sparing features keep memory redundancy between
memory channels by monitoring or altering memory active/inactive status, respectively.
Express5800/R120e-1M
User’s Guide
71
Chapter 2 Preparations
1. Installing Internal Optional Devices
(1) Memory Mirroring Feature
Memory Mirroring feature writes the same data into two groups of DIMMs (mirror set) corresponding with each
other between memory channels (channels 0 and 1 or channel 2 and 3) to provide data redundancy.
Note
• Memory Mirroring feature uses channels 0 and 1 or channels 2 and 3.
• To use Memory Mirroring feature, install N8102-548/549/550 additional memory
board (two DIMMs of same model).
• DIMMs used in mirror set must be of the same model number.
Example: 2-CPU configuration
Memory controller
Data 1
Data 2
Data 3
Data 4
Mirror set
#9
Mirror set
#11
Mirror set
#5
Mirror set
#7
Mirror set
#1
Mirror set
#3
Data 1
Data 2
Data 3
Data 4
Memory controller
Mirror set
#10
Mirror set
#12
Mirror set
#6
Mirror set
#8
Mirror set
#2
Mirror set
#4
Tips
72
The operating system only recognizes a half of the total physical capacity.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
Memory Mirroring feature can be used under the following conditions:
•
Install DIMMs in two DIMM sockets configuring a mirror set.
•
All the installed DIMMs should have the same capacity.
•
See Chapter 2 (1. System BIOS) in "Maintenance Guide", check if your server supports Memory Mirroring
feature.
Select Advanced → Memory Configuration → Memory Information, and check if Supported is
displayed in Mirroring.
•
See Chapter 2 (1. System BIOS) in "Maintenance Guide", run SETUP, change parameters as shown
below, save the settings, and exit from SETUP.
Advanced → Memory Configuration → Memory RAS Mode → Change to Mirroring.
•
After restart, run SETUP again, and check if "Mirrored" is displayed for the following parameter.
Advanced → Memory Configuration → Memory Information → CPUx_DIMMx Status
•
Installation order depends on CPU configuration. See the figure below.
1CPU
1CPU
構成
configuration
搭載順序
2CPU
2CPU
構成
configuration
搭載順序
2
4
6
2
4
6
3
7
11
3
7
11
CPU1_DIMM 3
CPU1_DIMM 7
CPU1_DIMM 11
CPU1_DIMM 4
CPU1_DIMM 8
CPU1_DIMM 12
5
3
1
5
3
1
9
5
1
9
5
1
4
8
12
4
8
12
CPU1_DIMM 10
CPU1_DIMM 6
CPU1_DIMM 2
CPU1_DIMM 9
CPU1_DIMM 5
CPU1_DIMM 1
CPU2_DIMM 3
CPU2_DIMM 7
CPU2_DIMM 11
CPU2_DIMM 4
CPU2_DIMM 8
CPU2_DIMM 12
10
6
2
10
6
2
CPU2_DIMM 10
CPU2_DIMM 6
CPU2_DIMM 2
CPU2_DIMM 9
CPU2_DIMM 5
CPU2_DIMM 1
Memory Mirroring cannot be configured in the following case:
•
Memory Mirroring within a specific memory channel
Notes on Configuring Memory Mirroring
In Memory Mirroring configuration, [Memory RAS Mode] menu is changed from "Mirroring" to "Independent" in
the following cases:
•
•
When you additionally install DIMMs that unable to configure Memory Mirroring
When you remove DIMMs that takes down Memory Mirroring
Express5800/R120e-1M
User’s Guide
73
Chapter 2 Preparations
1. Installing Internal Optional Devices
(2) Memory Lock Step Feature (x8 SDDC)
In Memory Lock Step feature, the DIMMs in two groups corresponding to two memory channels (channels 0
and 1, or channels 2 and 3) is multiplexed and operated in parallel to enable x8 SDDC (x8 Single Device Data
Correction). With this feature, a single device can detect and correct one to eight-bit error.
Note
• Memory LockStep feature uses channels 0 and 1 or channels 2 and 3.
• To use Memory LockStep feature, install N8102-548/549/550 additional memory
board (two DIMMs of same model).
• DIMMs used in LockStep set must be of the same model number.
Memory controller
LockStep Set
#9
LockStep Set
#11
LockStep Set
#5
LockStep Set
#7
LockStep Set
#1
LockStep Set
#3
Memory controller
74
LockStep Set
#10
LockStep Set
#12
LockStep Set
#6
LockStep Set
#8
LockStep Set
#2
LockStep Set
#4
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
Memory Lock Step feature can be used under the following conditions:
•
Install DIMMs that operate in parallel in DIMM socket.
•
All the installed DIMMs should have the same capacity.
•
See Chapter 2 (1. System BIOS) in "Maintenance Guide", run SETUP, change parameters as shown
below, save the settings, and exit from SETUP.
Advanced → Memory Configuration → Memory RAS Mode → Change to LockStep.
•
After restart, run SETUP again, and check if "Lock Step" is displayed for the following parameter.
Advanced → Memory Configuration → Memory Information → CPUx_DIMMx Status
•
Installation order depends on CPU configuration. See the figure below.
1CPU
1CPU
構成
configuration
搭載順序
2CPU
2CPU
構成
configuration
搭載順序
2
4
6
2
4
6
3
7
11
3
7
11
CPU1_DIMM 3
CPU1_DIMM 7
CPU1_DIMM 11
CPU1_DIMM 4
CPU1_DIMM 8
CPU1_DIMM 12
5
3
1
5
3
1
9
5
1
9
5
1
4
8
12
4
8
12
CPU1_DIMM 10
CPU1_DIMM 6
CPU1_DIMM 2
CPU1_DIMM 9
CPU1_DIMM 5
CPU1_DIMM 1
CPU2_DIMM 3
CPU2_DIMM 7
CPU2_DIMM 11
CPU2_DIMM 4
CPU2_DIMM 8
CPU2_DIMM 12
10
6
2
10
6
2
CPU2_DIMM 10
CPU2_DIMM 6
CPU2_DIMM 2
CPU2_DIMM 9
CPU2_DIMM 5
CPU2_DIMM 1
Memory Lock Step cannot be configured in the following cases:
•
•
Memory Lock Step between memory channels of different memory controllers (CPU)
Memory Lock Step within the same memory channel
Notes on Configuring Lock Step
In Memory Lock Step configuration, Memory RAS Mode menu is changed from "Lock Step" to "Independent"
in the following cases:
•
•
When you additionally install DIMMs that unable to configure Memory Lock Step
When you remove DIMMs that takes down Memory Lock Step
Express5800/R120e-1M
User’s Guide
75
Chapter 2 Preparations
1. Installing Internal Optional Devices
(3) Memory Sparing Feature
Memory Sparing feature puts a memory channel 2 of a memory controller in each CPU into standby status as
spare devices. If a correctable error occurs in a DIMM in the running memory controller, the feature
automatically changes the running DIMM from the failed one to a DIMM in the standby state to continue the
processing.
Note
To use Memory Sparing feature, install N8102-552/553/554 additional memory
board (three DIMMs of same model).
DIMMs installed in the system must be of the same model number.
Tips
The operating system recognizes the DIMMs as those with capacities less than
the actual physical capacities. (The recognized capacities vary depending on the
number of DIMMs and the physical capacity per DIMM.)
The following table shows configuration allowable for memory sparing and system logical memory capacity.
Number of
CPUs
Number of
DIMMs
1
2
76
Capacity of DIMM installed
4GB
8GB
16GB
3
8GB
16GB
40GB
6
16GB
32GB
80GB
9
24GB
48GB
120GB
12
32GB
64GB
160GB
6
16GB
32GB
80GB
12
32GB
64GB
160GB
18
48GB
96GB
240GB
24
64GB
128GB
320GB
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
Memory controller
Standby
Running
Spare set
#1
Spare set
#3
Spare set
#5
Spare set
#7
Memory controller
Standby
Running
Spare set
#2
Spare set
#4
Spare set
#6
Spare set
#8
Memory Sparing feature can be used under the following conditions:
•
DIMMs to be installed should have the same capacity.
•
See Chapter 2 (1. System BIOS) in "Maintenance Guide", check if your server supports Memory Sparing
feature.
Select Advanced → Memory Configuration → Memory Information, and check if Supported is
displayed in Sparing.
•
See Chapter 2 (1. System BIOS) in "Maintenance Guide", run SETUP, change parameters as shown
below, save the settings, and exit from SETUP.
Advanced → Memory Configuration → Memory RAS Mode → Change to Sparing.
•
After restart, run SETUP again, and check if "Spared" is displayed for the following parameter.
Advanced → Memory Configuration → Memory Information → CPUx_DIMMx Status
•
Installation order depends on CPU configuration. See the figure below.
Express5800/R120e-1M
User’s Guide
77
Chapter 2 Preparations
1. Installing Internal Optional Devices
1CPU
1CPU
構成
configuration
搭載順序
2CPU
2CPU
構成
configuration
搭載順序
3
3
3
4
4
4
5
5
5
7
7
7
CPU1_DIMM 3
CPU1_DIMM 7
CPU1_DIMM 11
CPU1_DIMM 4
CPU1_DIMM 8
CPU1_DIMM 12
2
2
2
1
1
1
3
3
3
1
1
1
6
6
6
8
8
8
CPU1_DIMM 10
CPU1_DIMM 6
CPU1_DIMM 2
CPU1_DIMM 9
CPU1_DIMM 5
CPU1_DIMM 1
CPU2_DIMM 3
CPU2_DIMM 7
CPU2_DIMM 11
CPU2_DIMM 4
CPU2_DIMM 8
CPU2_DIMM 12
4
4
4
2
2
2
CPU2_DIMM 10
CPU2_DIMM 6
CPU2_DIMM 2
CPU2_DIMM 9
CPU2_DIMM 5
CPU2_DIMM 1
The following Memory Sparing cannot be configured.
•
A DIMM of different capacity is installed.
Notes on Configuring Memory Sparing
In Memory Sparing configuration, Memory RAS Mode menu is changed to "Independent" in the following
cases:
•
•
78
When you additionally install DIMMs that unable to configure Memory Sparing
When you remove DIMMs that takes down Memory Sparing
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.11 Extra Battery / Flash Backup Unit for RAID Controller
If a RAID Controller (N8103-161/168/172/173/174) is installed, use the extra battery or flash backup unit (FBU)
to avoid data loss caused by accidents including temporary blackout during a Write Back operation. The model
of the extra battery and flash backup unit to be used depends on RAID Controller.
•
•
1.11.1
For N8103-172/173/174, use N8103-153.
For N8103-161/168, use FBU.
Handling precautions
Observe the following when using extra battery or FBU. Ignoring these precautions may cause damage to your
data or other devices.
•
Use the extra battery or FBU appropriate to the RAID Controller to be used.
•
The extra battery is an electronic device sensitive to static electricity. Before installation, touch the metal
frame part of the server to discharge the static electricity from your body.
•
Do not drop or bump the extra battery or FBU.
•
For recycling and disposing of the extra battery or FBU, refer to the User’s Guide that comes with the
RAID Controller or extra battery.
1.11.2
Installing Battery (N8103-153/162)
This section describes the procedure of installing a battery for RAID Controller (N8103-149/150/151/160).
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the two screws and remove PCI
riser card.
3.
Remove the support bar.
Express5800/R120e-1M
User’s Guide
79
Chapter 2 Preparations
80
1. Installing Internal Optional Devices
4.
Remove a single screw and remove battery
tray for RAID Controller.
5.
Connect a cable that comes with extra
battery to the extra battery.
When connecting the cable, pay attention to
the shape of connector, and align the
connector on extra battery with black marking
on battery control cable.
6.
Install the additional battery to the battery
tray by using 3 screws.
The installation position of the battery
depends on installed RAID Controller. See
the figure on the right.
Install N8103-162 additional battery to the
position for PCI slot #1 or #1C.
7.
Install the battery tray for RAID Controller
using a single screw removed in Step 4.
8.
Remove the two screws from RAID
Controller, and remove PCI bracket.
9.
Connect the cable of extra battery to RAID
Controller.
Align the connector on battery control cable
with the black making on RAID Controller,
then connect the battery control cable.
Express5800/R120e-1M
PCI #1B
または#1C
Attach
the
battery for
搭載 RAID
コントローラ用
RAID
Controller
installed
バッテリ取り付け位置
in PCI slot #1B or #1C
User’s Guide
PCI #1A
Attach
the battery for
搭載 RAID
コントローラ用
RAID
Controller
installed
バッテリ取り付け位置
in
PCI slot #1A
Chapter 2 Preparations
1. Installing Internal Optional Devices
10. Remove the two screws from server chassis,
and remove the RAID Controller bracket.
11. Install the RAID Controller bracket to RAID
Controller using two screws you have
removed in Step 8.
12. Install RAID Controller to the RAID Controller
connector on motherboard, using two screws
you have removed in Step 10.
13. Connect Mini SAS cable to RAID Controller.
14. Install support bar and PCI riser card you
have removed in Steps 2 and 3.
1.11.3
Removal
For removing the battery for the RAID Controller, reverse the installation procedure.
1.11.4
Installing FBU
Take the steps below to install FBU.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
Express5800/R120e-1M
User’s Guide
81
Chapter 2 Preparations
2.
1. Installing Internal Optional Devices
Remove the two screws, then remove the
PCI riser card.
3.
Remove the support bar.
4.
Remove one screw, then remove the battery
tray for RAID Controller.
5.
Put the FBU, provided as the standard
accessory of RAID Controller, on the battery
tray. Then, mount the FBU bracket, provided
as the standard accessory of RAID
Controller, and secure it with a screw.
6.
Connect the FBU control cable (600 mm),
provided as the standard accessory of RAID
Controller, to FBU.
7.
Mount the battery tray for RAID Controller
(removed in Step 4) with a screw.
82
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
8.
1. Installing Internal Optional Devices
Connect the FBU control cable (600 mm in
length) and Mini SAS cable to RAID
Controller. Align the black marking on
connector of FBU control cable with that
on connector of RAID Controller.
9.
Remove one screw from the blank cover
on the PCI riser card (removed in Step 2)
on which you are going to mount the RAID
Controller, then remove the blank cover.
10. Mount the RAID Controller to PCI riser
card, and secure it with one screw you
have removed in Step 9.
11. Mount the support bar you have removed
in Steps 2 and 3.
Note
1.11.5
Keep the removed blank cover for future use.
Removing FBU
Remove the FBU in reverse order of installation procedure.
Express5800/R120e-1M
User’s Guide
83
Chapter 2 Preparations
1.12
1. Installing Internal Optional Devices
LAN Riser Card
The server supports LAN Riser Card that allows a LAN port to be added.
Install LAN Riser Card to the LAN Riser Card slot on motherboard. The motherboard has one slot to install
LAN Riser Card.
Important
You must avoid static electricity to work with the procedure below. For
details, see Chapter 2 (1.2 Anti-static Measures).
1.12.1
Installation
Follow steps below to install LAN Riser Card.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the scrw that secures the PCI riser card, and remove the PCI riser card.
3.
Remove the screw from the blank cover.
4.
Remove the blank cover.
Note
84
Keep the removed cover for future use.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
5.
1. Installing Internal Optional Devices
Remove two screws from the motherboard.
Screws
1.12.2
6.
Align the pin terminals of LAN Riser Card with the LAN Riser Card slot, and insert the card securely.
7.
Secure the bracket of LAN Riser Card with two screws you have removed in step 5.
8.
Install the port cover provided with LAN Riser Card.
Removal
Remove LAN Riser Card in reverse order of installation steps.
Important
To maintain the cooling effect in the server, install the blank cover in the
vacant LAN Riser Card slot.
Express5800/R120e-1M
User’s Guide
85
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.13 PCI Card
This server provides a riser card for PCI card and a slot for RAID controller. The riser card can connect one
Full Height PCI card, one Low Profile PCI card and one RAID controller (total three PCI card can be
mounted).
Important
You must avoid static electricity to work with the procedure below. For
details, see Chapter 2 (1.2 Anti-static Measures).
1.13.1
Notes
Read the following notes when installing or removing a PCI card.
•
Do not touch the terminals of the riser cards and the leads of electronic components with your bare
hand. Fingerprints and dust left on them cause the server to malfunction due to a connection failure or
damage to the leads.
•
Available type of PCI card depends on riser card. Make sure the card type before connecting it to riser
card.
•
The server provides no connector to connect a LED connector which is supplied in RAID Controller
used to indicate disk access.
•
PCI slot number "1C" is assigned to the riser card for Low Profile PCI cards, "1B" is assigned to the
riser card for Full Height PCI cards, "1A" is assigned to the RAID controller slot, “1D” is assigned to LAN
Riser Card slot.
•
The search order for PCI bus slot on boot is as follows.
Slot 1A (dedicated to RAID Controller) → Slot 1B (Full height card slot) → Slot 1C (Low profile card slot)
→ Slot 1D (dedicated to LAN riser card)
•
The PCI devices of the same type (including onboard PCI device) may be recognized in different order
from that described above, depending on OS or RAID Configuration Utility. Check the slot location of
PCI device by PCI bus number, device number and function number shown in the table below.
PCI device
86
Bus number
Device number
Function number
Onboard LAN1
02h
0
0
Onboard LAN2
02h
0
1
RAID controller slot 1A
21h
0
×
Slot 1B (Full Height)
25h
0
×
Slot 1C (Low Profile)
2Dh
0
×
LAN Riser Card slot 1D
03h
0
×
•
If an additional LAN card is installed, it is hard to push the catch of the connector with your finger that is
connected to the LAN card. Disconnect the connector pushing the catch with a standard screwdriver. At
this time, be very careful for the screwdriver not to damage the LAN card.
•
If a bootable device such as a PCI card or USB device is added, the boot order may change.
In BIOS Setup Utility, select Hard Drive BBS Priorities from Boot menu, and then specify a higher
priority for the boot device.
Boot → Hard Drive BBS Priorities → Check the display
If the boot device is an HDD under an optional RAID Controller, the display is (Bus xx Dev 00) PCI
RAID Adapter. Note that the value for xx changes depending on the PCI slot where a RAID board is
installed.
•
For a RAID Controller, LAN card (network boot), or Fibre Channel controller, if no hard disk drive on
which an OS is installed is connected, set the option ROM for that slot to Disabled. See Chapter 2 (1.
Detail of System BIOS) in "Maintenance Guide" for how to specify it.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.13.2
1. Installing Internal Optional Devices
Supported boards and available slots
The following tables list supported boards and slots available for them. For details of the features of each
board, see the manual supplied with it.
• Different boards mounted on the same bus operate at the lower frequency.
Tips
• When the operation performance of a PCI card is higher than the PCI slot on the
server, the PCI card operates with the performance of the PCI slot on the
server.
(1) Standard riser cards
Slot number
PCI slot
performance*1
PCIe 3.0
PCIe 3.0
PCIe 3.0
PCIe 3.0
#1A
#1B
#1C
#1D
x8 lane
x16 lane
Transfer bandwidth
Model
Product
name
name
8Gb/s
(per lane) *1
Dedicated
Slot size
to RAID
Full height
Controller
PCI card type *2
x8 lane
x8 socket
Low
profile
x16 socket
to RAID
RAID Controller
○
riser card
Dedicated
Up to 220 mm
Controller
N8103-172
Remarks
to LAN
x8 socket
Dedicated
Available card size
Dedicated
to LAN
riser card
-
-
-
(512MB, RAID 0/1)
Dedicated to connecting
internal disks.
[PCI Express 3.0(x8)]
An extra battery
N8103-173
RAID Controller
○
-
-
-
(512MB, RAID 0/1/5/6)
[N8103-153] can be
mounted.
[PCI Express 3.0(x8)]
N8103-174
RAID Controller
○
-
-
-
-
○
○
-
(1GB, RAID 0/1/5/6)
[PCI Express 3.0(x8)]
N8103-168
RAID Controller
Dedicated to connecting
(1GB, RAID 0/1/5/6)
internal disks.
[PCI EXPRESS 3.0(x8)]
FBU is factory installed.
Cannot be installed
together with
N8103-172/173/174.
N8103-161
RAID Controller
-
○
○
-
Dedicated to connecting
(1GB, RAID 0/1/5/6)
external devices..
[PCI EXPRESS 2.0(x8)]
FBU is factory installed.
Up to two extra battery
and/or FBU can be
installed.
Express5800/R120e-1M
User’s Guide
87
Chapter 2 Preparations
1. Installing Internal Optional Devices
Slot number
PCI slot
performance*1
PCIe 3.0
PCIe 3.0
PCIe 3.0
PCIe 3.0
#1A
#1B
#1C
#1D
x8 lane
x16 lane
Transfer bandwidth
Model
Product
name
name
8Gb/s
(per lane) *1
Dedicated
Slot size
to RAID
Full height
Controller
PCI card type *2
x8 lane
x8 socket
Low
profile
x16 socket
to RAID
-
SAS Controller
riser card
Dedicated
Up to 220 mm
Controller
N8103-142
to LAN
riser card
○
○
-
[PCI Express 2.0(x8)]
N8190-153
N8190-154
Remarks
to LAN
x8 socket
Dedicated
Available card size
Dedicated
For connecting external
devices.
-
Fibre Channel Controller
○
○
-
For connecting external
(8Gbps/Optical)
Fibre Channel device.
[PCI Express 2.0(x8)]
Cannot be installed
Fibre Channel Controller(2ch)
-
○
○
-
together with
N8190-157/158.
(8Gbps/Optical)
[PCI Express 2.0(x8)]
N8190-157
-
Fibre Channel Controller
○
○
-
(16Gbps/Optical)
Fibre Channel device.
[PCI Express 3.0(x8)]
N8190-158
For connecting external
Cannot be installed
Fibre Channel Controller(2ch)
-
○
○
-
together with
N8190-153/154.
(16Gbps/Optical)
[PCI Express 3.0(x8)]
N8104-135
1000BASE-T Riser Card (2ch)
-
-
-
○
[PCI Express 2.0(x1)]
For additional LAN port.
Card type: PCI Express
2.0(x8)
N8104-138
1000BASE-T Adapter (1ch)
-
○
○
-
[PCI Express 2.0(x1)]
For additional LAN port.
Card type: PCI Express
2.0(x4)
N8104-132
1000BASE-T Adapter (2ch)
-
○
○
-
[PCI Express 2.0(x1)]
For additional LAN port.
Card type: PCI Express
2.0(x4)
N8104-133
1000BASE-T Adapter (4ch)
-
○
○
-
[PCI Express 2.0(x4)]
For additional LAN port.
Jumbo frame not
supported.
LAN cable with
protective cap cannot be
used.
N8104-136
10GBASE-T Adapter (2ch)
-
-
-
[PCI Express 2.0(x8)]
○
For additional LAN port.
Up to two cards
including
N8104-136/128/148/131
can be installed.
88
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
Slot number
PCI slot
performance*1
PCIe 3.0
PCIe 3.0
PCIe 3.0
PCIe 3.0
#1A
#1B
#1C
#1D
x8 lane
x16 lane
Transfer bandwidth
8Gb/s
(per lane) *1
Model
Product
name
name
Dedicated
Slot size
to RAID
Full height
Controller
PCI card type *2
x8 lane
x8 socket
Low
profile
x16 socket
to RAID
-
10GBASE-SFP+ riser card
riser card
Dedicated
Up to 220 mm
Controller
N8104-137
Remarks
to LAN
x8 socket
Dedicated
Available card size
Dedicated
to LAN
riser card
-
-
○
[PCI Express 2.0(x8)]
For additional LAN port.
Prepare SFP+ module
[N8104-129] if needed.
Up to two cards
including
N8104-137/128/148/131
can be installed.
N8104-128
10GBASE Adapter (SFP+/2ch)
-
○
○
-
[PCI Express 2.0(x8)]
For additional LAN port.
Prepare SFP+ module
[N8104-129] if needed.
N8104-148
10GBASE Adapter (SFP+/2ch)
-
○
○
-
Only one card can be
installed in RHEL6.
[PCI Express 2.0(x8)]
Up to two cards
including
N8104-136/137/128/148/
131 can be installed.
N8104-131
-
10G Converged Network
○
○
-
For additional
Adapter (2ch) (10Gbps/Optical)
DCB/FcoE.
[PCI Express 2.0(x8)]
SFP+ module is
factory-installed.
StoragePathSavior
supports redundant path
of FC.
Teaming/bonding with
LAN is not available.
Only one port per
system can be used as
LAN of N8104-131.
Only one card can be
installed in RHEL6.
Up to two cards
including
N8104-137/128/131 can
be installed.
N8117-01A
Additional RS-232C connector
-
-
○
*3
-
For additional serial port
B (RS-232C).
√: Can be mounted, –: Cannot be mounted
*1
*2
*3
Data transfer rate of PCI slot = Transfer bandwidth × Number of lanes
<Example> x8 lane = 64 Gbps (one-way)
Connector size. Cards exceeding the number of sockets cannot be connected.
<Example> x4 socket can connect with x1 and x4 cards, but not x8 card.
Use RS-232C cable (B).
Express5800/R120e-1M
User’s Guide
89
Chapter 2 Preparations
1.13.3
1. Installing Internal Optional Devices
Installation
Install a riser card to a PCI card in the following procedure.
Important
When installing a PCI card, make sure the connector of the board fits the
connector of the riser card.
• Check the board type (Low Profile or Full Height) which respective riser card
Note
supports and the type of PCI card to be installed.
• When installing an extra battery for RAID Controller or FBU, see Chapter 2
(1.11 Extra Battery / Flash Backup Unit for RAID Controller).
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the screw securing the PCI riser
card. Hold the both ends of the PCI riser
card and lift it off.
3.
Confirm the installation position with the reference to the table on 1.14.2 Supported boards and
available slots.
4.
Remove the screw from the PCI riser
card and remove the blank cover.
PCIe #1C
Low profile side
PCIe #1B
Full Height side
Note
5.
Keep the removed blank cover for future use.
Install a PCI card to the PCI riser card.
When installing the card, position the
terminal part of the PCI card to the PCI
riser card slot and insert it.
Important
Do not touch the terminal part of riser card or PCI card and the signal pins
of electric parts installed on the board. Installing boards with dirt or oil can
cause malfunction.
Note
• Make sure that the head of a PCI card bracket is seated into the fixed slot.
• Depending on type of PCI cards, the terminal part of the PCI card may be too
large to fit in the connector.
• If you have trouble installing the card, remove the card once and try again. If you
apply excessive pressure on the card, a PCI card or riser card might break.
90
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
6.
1. Installing Internal Optional Devices
Fix the PCI card with the screw you removed at step 4.
PCIe
#1C
Low Profile side
PCIe#2
ロープロファイル側
Tips
PCIe
#1B
Full Height side
PCIe#1
ロープロファイル側
To connect a PCI card to the connector on motherboard with cable, connect a
cable to PCI card before installing PCI riser card.
7.
Connect the PCI riser card to the
motherboard slot and fix the card with
the screw you removed at step 2.
When connecting the card, position the
terminal part of the PCI riser card to the
slot on the motherboard and insert it.
8.
Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
9.
Make sure that no error messages are displayed on POST screen.
For details on POST error messages, see Chapter 3 (1. POST Error Message) in "Maintenance
Guide".
10. Start the configuration utility installed on the mounted board to set up the board.
Availability or startup and operation procedure of the utility depends on board. For details, see the
manual that comes with the board. If a PCI card including RAID Controller and LAN adapter
which connects to any bootable device is added, the boot priority might be changed to the
default setting. In that case, configure the boot priority in Boot menu of BIOS Setup Utility. For
details, see Chapter 2 (1. Detail of System BIOS) in "Maintenance Guide".
1.13.4
Removal
To remove a PCI card, reverse the installation procedure.
Run SETUP and change boot order in Boot menu. See Chapter 2 (1. Details of System BIOS) in "Maintenance
Guide" for how to specify it.
If using the server while the card is removed, attach the blank cover that comes with the riser card.
Express5800/R120e-1M
User’s Guide
91
Chapter 2 Preparations
1.13.5
1. Installing Internal Optional Devices
Installing RAID Controller
This section describes how to install an optional RAID Controller to the slot dedicated to RAID Controller.
(1) When using the optional RAID controller (N8103-172/173/174)
For details, see the manual that comes with optional RAID Controller (N8103-172/173/174).
Important
• You must avoid static electricity to work with the procedure below. For
details, see Chapter 2 (1.2 Anti-static Measures).
• Do not change the mode to hibernate while building a RAID System.
Note
• When installing an optional RAID Controller, start the BIOS Setup utility, select
PCI Configuration from the Advanced menu, and then make sure that the
parameter of PCI Slot xx ROM (xx is PCI slot number) is set to Enabled.
• When connecting a RAID Controller, set the boot priority to 8th or higher in the
Boot menu of the BIOS Setup utility. If the setting is 9th or lower, the
configuration menu for RAID Controllers cannot be launched.
Take the following procedure to install RAID Controller (N8103-172/173/174).
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the two screws and remove PCI
riser card.
3.
Remove the support bar.
4.
Remove the two screws from RAID
Controller, and remove PCI bracket.
5.
Remove the two screws from server
chassis, and remove RAID Controller
bracket.
6.
Attach the RAID Controller bracket to
RAID Controller with two screws you
have removed in Step 4.
Ports 4-7
Ports 0-3
7.
92
Insert RAID Controller into the slot dedicated to RAID Controller.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
8.
Secure the RAID Controller bracket with two screws you have removed in Step 5.
9.
Disconnect SAS/SATA cable from SATA connector on motherboard.
9-1.
When four or less hard disk drives are installed:
Connect SAS/SATA cable removed in Step 9 to connector (Ports 0-3) on RAID Controller.
9-2.
When five or more hard disk drives are installed:
Connect SAS/SATA cable removed in Step 9 to connector (Ports 0-3) on RAID Controller.
Connect SAS/SATA cable provided with the server to connector (Ports 4-7) on RAID Controller.
Remove a single screw from server chassis, and remove battery tray for RAID Controller.
Connect another end of SAS/SATA cable that has been connected to connector (Ports 4-7) on
RAID Controller, to the connector on backplane.
Secure the battery tray for RAID Controller with a single screw.
10. Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
(2) When using optional RAID Controller (N8103-161/168)
See Chapter 2 (1.14.4 Installing FBU).
Express5800/R120e-1M
User’s Guide
93
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.14 Additional HDD Cage
This server can have additional HDD cage for installing additional hard disk drives. The additional HDD cage is
installed on front side of the server, and is used exclusively with the optical disk drive.
1.14.1
Installation
Follow steps below to install an additional HDD cage.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
If an optical disk drive is already installed, disconnect the cable from optical disk drive.
3.
Remove the screw that secures the optical disk drive bay bracket.
4.
Pull out the optical disk drive bay bracket to the direction shown by an arrow.
Note
94
Keep the removed bracket for future use.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
5.
1.14.2
1. Installing Internal Optional Devices
Install the additional HDD cage to the chassis, and secure it with screws.
Removal
To remove additional HDD cage, reverse the installation procedure.
Important
• Before removing additional HDD cage, be sure to remove hard disk drives
installed in that cage.
• Be sure to install a bracket to maintain cooling effect in server.
Express5800/R120e-1M
User’s Guide
95
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.15 Optical Disk Drive
This section describes the procedure for installing the optional optical disk drive.
Important
Do not install any unsupported optical disk drive.
Optical disk drive bay
1.15.1
Installation
Install an optical disk drive in the following procedure.
1.
See steps 1 to 6 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the two screws from the optical
disk drive bay, and pull the bay out.
3.
Remove a single screw from the bay you
have removed in Step 2, and remove the
bracket.
Screw
4.
Remove the dummy cover.
Note
96
Keep the removed screws and dummy cover for future use.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
5.
1. Installing Internal Optional Devices
Install the optical disk drive to the tray.
Screw holes
Hooks
6.
Secure the bracket to optical disk drive
with a screw you have removed in Step 3.
Screw
1.15.2
7.
Insert the optical disk drive and secure the
drive tray with two screws you have
removed in Step 2.
8.
Connect the optical disk drive cable.
Removal
To remove an optical disk drive, reverse the installation procedure above.
Express5800/R120e-1M
User’s Guide
97
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.16 Use of Internal Hard Disk Drives in the RAID System
This section describes how to use the internal hard disk drives in the RAID System.
Important
If you use hard disk drives in the RAID System or change the RAID level,
initialize the hard disk drives. If the hard disk drive contains valuable data,
be sure to backup the hard disk drive before installing the RAID Controller
and configuring the RAID System.
Note
In the RAID System, use hard disk drives that have the same specifications
(capacity, rotational speed, and standard) for each Disk Array.
Tips
Logical Drives can be created even with only one Physical Device.
If using internal hard disk drives in RAID System with an optional RAID Controller (N8103-168/172/173/174)
installed in the server, the SATA cable needs to be rewired.
Tips
98
When using SAS hard disk drives, RAID Controllers must be connected.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.16.1
1. Installing Internal Optional Devices
Connecting cables
See the figures below for how to connect cables.
If using optional RAID Controller (1 to 6 hard disk drives)
SATA0 SATA1 SATA2 SATA3
Ports 0-3
Ports 4-7
SATA7 SATA6 SATA5 SATA4
Optional RAID Controller
Hard Disk Drive
Backplane
SLOT 0
SATA 0
SLOT 1
SATA 1
SLOT 2
SATA 2
SLOT 3
SATA 3
SLOT 4
SATA 4
SLOT 5
SATA 5
−
−
−
−
Hard Disk Drive
Backplane
SLOT 0
SATA 0
SLOT 1
SATA 1
SLOT 2
SATA 2
Ports 0-3
Ports 4-7
When optional 2.5-inch HDD cage is installed
Optional RAID Controller
Ports 0-3
Ports 4-7
SLOT 3
SATA 3
SLOT 4
SATA 4
SLOT 5
SATA 5
SLOT 6
SATA 6
SLOT 7
SATA 7
Express5800/R120e-1M
User’s Guide
99
Chapter 2 Preparations
1.16.2
1. Installing Internal Optional Devices
Notes on Building RAID System
Note the following points when setting up a RAID System.
•
•
The number of hard disk drives required varies in each RAID level.
If the optional RAID Controller is used, the RAID System cannot be built in
RAID5/RAID6/RAID50/RAID60.
The minimum number of hard disk drives required to set up a RAID System
RAID level
N8103-172
N8103-168/173/174
RAID 0
1
1
RAID 1
2
2
RAID 5
3
RAID 6
3
RAID 10
•
•
4
4
RAID 50
6
RAID 60
6
In the RAID System, all the hard disk drives in a group (pack) must have the same capacity, interface
type, and rotational speed.
If you intend to install the OS to the RAID System, the process from RAID configuration to OS installation
can be easily completed by using EXPRESSBUILDER. If you wish to install the OS manually, use RAID
System Configuration utility (WebBIOS). The utility can be run during POST which starts immediately
after the server is turned on. For details, see Chapter 2 (4. RAID System Configuration) in "Maintenance
Guide" or the manual supplied with the optional RAID Controller (N8103-168/172/173/174).
Important
• Do not change the mode to hibernate while building a RAID System.
• Build a Disk Array in the RAID System using hard disk drives that have the
same specifications (capacity, rotational speed, and standard).
100
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.17 Installing Top Cover
When all internal optional devices are installed, close the server with Top Cover.
1.
Put Top Cover straight on the server chassis so that it can be surely engaged with the chassis frame.
2.
Slide Top Cover toward the front of the server.
3.
Tighten the thumb nut on rear of the server.
Express5800/R120e-1M
User’s Guide
101
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.18 Hard Disk Drive
Expansion Bays for hard disk drives are provided at the front of the server.
A hard disk drive mounted in a dedicated drive tray can be purchased. Install the hard disk drive on the server
with it mounted in the drive tray.
Important
Use hard disk drives specified by NEC. Installing a third-party hard disk
drive might cause a failure of the server and it.
Note the following precautions to install hard disk drives.
•
•
•
For onboard connection, hard disk drives having different capacities, types, or rotational speeds cannot
be installed together.
In the RAID System, all the hard disk drives in a group (pack) must have the same capacity, type, and
rotational speed.
If using hard disk drives in a RAID System, jumper settings or a change of cables may be required.
Bays can accommodate up to 6 hard disk drives (when HDD cage is added, 8 HDDs can be installed).
slot numbers have been assigned to each slot.
<Standard configuration>
Slot 0
Slot 1
Slot 2
Slot 4
Slot 5
Slot 3
<With 2.5-inch HDD cage installed>
Slot 0
Slot 1
102
Slot 2
Slot 3
Slot 4
Slot 5
Express5800/R120e-1M
Slot 6
User’s Guide
Slot 7
Chapter 2 Preparations
1.18.1
1. Installing Internal Optional Devices
Installation
Install a hard disk drive by using the following procedure.
Note
In the RAID System, use hard disk drives that have the same specifications
(capacity, rotational speed, and standard) for each Disk Array.
1.
See Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Locate the slot where you install the hard disk drive.
The server has 6 slots (or 8 slots when additional HDD cage is installed). Install hard disk drives in
ascending port number order.
3.
Remove the dummy trays.
Dummy trays are installed in every slot
except for slot 0.
Note
Keep the removed dummy trays for future use.
4.
Unlock the handle of the tray.
5.
Hold the tray firmly and insert it into the
slot.
Note
• Push it all the way until the handle’s lock touches the frame.
• Hold the tray firmly with both hands.
Express5800/R120e-1M
User’s Guide
103
Chapter 2 Preparations
6.
1. Installing Internal Optional Devices
Slowly close the handle.
The tray is locked making a clicking sound.
Note
When you push the drive into the slot, confirm the handle got hooked on the
frame.
7.
Turn on the server, run BIOS Setup Utility, and then specify the boot order from Boot menu.
For details, see Chapter 2 (1. Details of System BIOS) in "Maintenance Guide"
Tips
1.18.2
The saved boot order is cleared when a hard disk drive is added.
Removal
To remove hard disk drive, reverse the installation procedure.
If you transfer or dispose of the removed hard disk drive, see Chapter 1 (1. Transfer, Movement, and Disposal)
in “Maintenance Guide” to erase data.
Important
NEC assumes no liability for data leakage should the product be
transferred to a third party without erasing the data.
Note
• If you remove a hard disk drive due to a failure, check the slot with its DISK LED
lit in amber.
DISK LED
• Do not pull the slot out from the handle. Doing so may damage the handle.
Turn on the server, start BIOS Setup Utility, and then specify the boot order from Boot menu.
For details, see Chapter 2 (1. Details of System BIOS) in "Maintenance Guide".
Tips
104
The saved boot order is cleared when a hard disk drive is added.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.18.3
1. Installing Internal Optional Devices
Replacing a hard disk drive in the RAID System (Auto Rebuild)
In the RAID System, you can use the auto rebuild feature to restore data back to the state before a failure
occurred.
The auto rebuild feature is enabled in logical drives set to RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, and
RAID60.
The disk array is automatically rebuilt when hot swapping (replacing a hard disk drive while the power on) a
failed hard disk drive.
During the auto rebuild, DISK LED on the hard disk drive flashes green and amber alternately to indicate that
the auto rebuild is being performed.
Observe the following precautions whenever executing the auto rebuild
•
•
•
Do not turn off the server until the auto build completes after a hard disk drive fails.
Leave an interval of at least 90 seconds between a hard disk drive removal and a hard disk drive
installation.
Do not replace a disk during the auto rebuilding of another hard disk drive (during an auto rebuild, DISK
LED on the hard disk drive flashes green and amber alternately).
Express5800/R120e-1M
User’s Guide
105
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.19 Power Supply Unit
This server can contain two power supply units. The server provides a redundant power configuration that
ensures continued operation of the system in the unlikely event one of the power supply units fails.
Select a suitable power supply unit according to System Configuration Guide.
Tips
1.19.1
AC power supply unit has a cable tie to prevent AC cable from slipping out.
Cold Redundant Feature
The server supports the feature to optimize power efficiency as described below:
•
•
Cold redundant feature can run the system with optimum power efficiency by raising operating efficiency
of primary power supply unit and lowering that of redundant power supply unit in redundant power
configuration.
If power efficiency of power units is not optimized due to system configuration, this feature is disabled
automaticlly.
Cold redundant feature can be used under the following conditions:
•
•
106
Two power supply units must be installed for redundant configuration.
See Chapter 2 (1. Details of System BIOS) in "Maintenance Guide", change parameters as shown below,
save the settings and exit from SETUP.
Server → Power Control Configuration → Cold Redundant Mode → Enabled
Run SETUP again, and check if the status of Cold Redundant Mode shows Enabled in Server menu.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.19.2
1. Installing Internal Optional Devices
Installation
Follow steps below to install a power supply unit:
1.
See steps 1 to 4 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations.
2.
Remove the blank cover.
Slot for standard
power supply unit
Slot for additional
power supply unit
REAR
Note
Keep the removed blank cover for future use.
3.
Insert the power supply unit until it is locked with clicking sound.
4.
Connect power cords.
Use the power cord that comes with the server and the one comes with the additional power supply
unit.
Power supply unit
(additional)
Power supply unit
(standard)
Power cord for
power supply unit
2
Power cord for
power supply unit
1
Express5800/R120e-1M
User’s Guide
107
Chapter 2 Preparations
1. Installing Internal Optional Devices
AC POWER LED blinks green when the power cord is connected to a power supply unit and the other
power supply unit’s AC POWER LED goes on amber.
When the power cord is connected to it, AC POWER LEDs on both power supply units blink green.
AC POWER LED
Standard
power supply unit
5.
Additional
power supply unit
Power on the server.
AC POWER LEDs go on green.
6.
Confirm, by STATUS LED or on POST screen, that there are no errors related to the power supply
units.
See Chapter 3 (1. POST Error Message) in “Maintenance Guide” for details on POST error
messages.
If AC POWER LEDs are off, reinstall the power supply units. If the same error occurs, contact with
your sales representative.
108
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
1.19.3
1. Installing Internal Optional Devices
Replacing a failing power supply unit
Replace only when the power supply unit fails.
To remove power supply unit, reverse the installation procedure.
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Pay attention to electric hazard.
Important
Do not remove a power supply unit operating normally.
Tips
In the redundant power configuration (with two power supply units) and if either one of
power supply units fails, the failing power supply unit can be replaced with the system
power on.
Important
To maintain the cooling effect in the server, install the blank cover in the vacant
slot.
Install the new power supply unit taking steps 3 to 6 of "Installation", and confirm that the power supply unit is
installed normally.
Express5800/R120e-1M
User’s Guide
109
Chapter 2 Preparations
1. Installing Internal Optional Devices
1.20 Installing Front Bezel
When installing Front Bezel, engage catch of front bezel with that on rails.
After installing Front Bezel, lock it with Bezel Lock Key.
Note
110
Be careful not to press POWER Switch.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
2.
2. Installation and Connection
Installation and Connection
This section describes how to install the server and connect cables.
2.1
Installation
This server must be mounted to a rack which conforms to EIA standards for use.
2.1.1
Installing Rack
Refer to the manual that comes with your rack for how to install the rack, or consult with your sales
representative.
WARNING
Be sure to observe the following precautions to use the server safety. Failure to
observe the precautions may cause death or serious injury. For details, refer to
Safety precautions in Precautions for Use.
• Use only in the specified environment.
• Do not connect the ground wire to a gas pipe.
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Do not carry or install the server only by a single person.
• Do not install the server so that the load may be concentrated on a specific
point.
• Do not install any components only by a single person. Confirm that hinge
pins of the door are completely secured in place.
• Do not pull out the server from the rack when the rack is unstable.
• Do not leave more than one device being pulled out from the rack.
• Do not provide the wiring for the server to exceed the rating of the power
supply.
• Do not use in the environment where corrosive gas is generated.
Express5800/R120e-1M
User’s Guide
111
Chapter 2 Preparations
2. Installation and Connection
Do not install the rack or server under the following environment. Doing so may cause malfunction of the
server.
112
•
Narrow space from which devices cannot be pulled out from the rack completely
•
Place that cannot bear the total weights of the rack and devices mounted on the rack
•
Place where stabilizers cannot be installed or where the rack can be installed only after the practice of
proper earthquake-resistant construction
•
Place of uneven or slanting floor
•
Place of drastic temperature change (near a heater, air conditioner, or refrigerator)
•
Place where intense vibration may be generated
•
Place where corrosive gases (sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia,
ozone, etc) exist
Place where the air (or dust) includes components accelerating corrosion (ex. sulfur, sodium chloride)
or conductive metals
•
Place where chemicals may be accidentally sprayed over
•
Place where a carpet not subject to anti-static process is laid
•
Place where some objects may be fallen on the rack
•
Place near a device generating intense magnetic field (such as TVs, radios, broadcast/communication
antennas, power transmission wires, and electromagnetic cranes) is placed.
•
Place where the power cord of the server must be connected to an AC outlet that shares the outlet of
another device with large power consumption
•
Place near equipment that generates power noise (e.g., contact spark at power-on/power-off of
commercial power supply through a relay).
•
Environment where operation of the server is not guaranteed
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
2.1.2
2. Installation and Connection
Installing the server to the rack or removing it from the rack
Mount the server to the rack. (This section also describes the removal procedure.)
WARNING
Be sure to observe the following precautions to use the server safety. Failure to
observe the precautions may cause death or serious injury. For details, refer to
Safety precautions in Precautions for Use.
• Do not use any racks out of standards.
• Use only under the specified environment.
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Do not drop.
• Do not leave the server being pulled out.
• Do not install with the cover removed.
• Do not get your fingers caught.
Important
Temperature increases and airflow in the rack
If multiple devices are installed, or if the inside of the rack is not sufficiently
ventilated, the internal temperature rises due to the heat emitted from each
device, which may result in a malfunction. Review airflow in the rack and
room and take sufficient measures so that the internal temperature will not
exceed the operational temperature during operation.
Air enters the server from the front and exits from the rear.
Express5800/R120e-1M
User’s Guide
113
Chapter 2 Preparations
2. Installation and Connection
Preparation
•
•
Checking rails
Installing inner and outer rails
Checking rails
Make sure the orientation of inner and outer rails by viewing labels on each rail.
R
Inner rail
Label
R
Outer rail
Installing inner rails
1.
Mount an inner rail marked as "R" to the right side of the server and "L" to the left side when viewed the
server from front.
2.
Align the locks and holes, and insert the
inner rails until it clicks.
Installing outer rails
114
1.
Mount an outer rail marked as "R" to the right side of the rack and "L" to the left side when viewed the
rack from front.
2.
Fit the square-shaped protrusions of outer
rail to the square holes of a 19-inch rack.
Make sure that it makes a clicking sound
indicating that it is locked.
The image on the right shows the front left
side of the rack. Install to the rear left side
and front and rear right sides following the
same procedure.
Make sure that the rail is installed at the
same height as the other rail already
installed.
Important
Confirm that the rail are securely locked so that they will not fall off.
Tips
Although the rail may be somewhat unsteady, it is not defective.
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
2. Installation and Connection
Installing/Removing the Server
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Do not attempt to lift the server with single person.
• Do not drop.
• Do not leave the server being pulled out.
• Do not install with the cover removed.
• Do not get your fingers caught.
(1) Installation
Mount the server to a rack in the following procedure.
Important
1.
Always install the server with two or more persons.
Pull the slide rail from the outer rail that is
mounted on rack until the slide rail is locked.
Note
Make sure that locking mechanism work normally.
Locked state
2.
Locking mechanism
With two or more persons, firmly hold the
server and mount it to the rack.
Express5800/R120e-1M
User’s Guide
115
Chapter 2 Preparations
3.
2. Installation and Connection
When the server is pushed into the rack and
is locked, push the server to the end while
pulling the release levers (blue) on both
sides of the server.
Release lever
4.
Push the server until its lock on front panel
clicks.
(2) Removal procedure
Remove the server from the rack in the following procedure.
Important
At least two persons are required to remove the server from rack.
1.
Make sure that the server is turned off and then disconnect the power cord or all interface cables from
the server.
2.
Remove the front bezel.
3.
Slowly pull the server out while pressing the
buttons located on either side of the front of
the server.
Press the button
to unlock
116
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
4.
2. Installation and Connection
Because there are stoppers, the server will
come to a stop halfway. Press and hold Rail
Stopper on the rails and pull the server out
of the rack.
Rail
Stopper
レールストッパー
Important
5.
Be careful not to get your fingers caught in the rails or lever.
Hold the server firmly and remove it from the rack.
Important
• While more than one person is supporting the bottom part of the server,
slowly pull out the server.
• Do not apply pressure on the server from top when it is being pulled out.
Doing so cause the server to drop.
(3) Removing Outer Rail
Remove outer rails from the rack in the following procedure.
1.
See Chapter 2 (2.1.2 Installing the server to the rack or removing it from the rack, (2) Removal
procedure) to remove the server from the rack.
2.
Push the unlock lever on outer rail to the
direction shown by arrow to house the slide
rail.
Unlock lever
ロック解除レバー
3.
Locking
mechanism
ロック機構
While pressing the lever on outer rail, push
the outer rail toward inside of the rack, then
remove it.
Express5800/R120e-1M
User’s Guide
117
Chapter 2 Preparations
2.2
2. Installation and Connection
Connection
Connect peripheral devices to the server.
Connectors that allow a variety of peripheral devices to be connected are provided at the front and rear of the
server. Images on the following pages show the peripheral devices that can be connected in their standard
state and their respective connector positions.
WARNING
Be sure to observe the following precautions to use the server safety. Failure to
observe the precautions may cause death or serious injury. For details, refer to
Safety precautions in Precautions for Use.
• Do not hold the power plug with wet hands
• Do not connect the ground wire to a gas pipe
CAUTION
Be sure to observe the following precautions to use the server safely. Failure to
observe the precautions may cause burns, injury, and property damage. For
details, refer to Safety precautions in Precautions for Use.
• Use only the specified outlet to insert.
• Do not connect the power cord to an outlet that has an illegal number of
connections.
• Insert the power plug into the outlet as far as it goes.
• Use only the specified power cord
• Do not connect or disconnect the interface cable with the power plugged in
the outlet.
• Use only the specified interface cable
118
Express5800/R120e-1M
User’s Guide
Chapter 2 Preparations
2. Installation and Connection
Display unit *2
USB device
FRONT
前面
Display unit *2
Finally, connect the provided
power cord to an outlet. *1
Hub, switching hub, etc.
For connecting with UPS, refer
to the next section.
Management
LAN port
Ports for data
transmission
REAR
背面
USB device
Device with serial interface
*1
*2
Connect the power cord to a circuit breaker of up to 15 A.
Either one can connect with a display unit.
Note
The serial port cannot be used to connect with leased line.
Express5800/R120e-1M
User’s Guide
119
Chapter 2 Preparations
2. Installation and Connection
Note the following precautions to connect cables.
•
•
•
•
2.2.1
When the device is not Plug and Play device, turn off the server and devices to be connected before
connecting.
If connecting any peripheral device and its interface cable made by other companies (a third party),
contact your sales representative to check if they can be used with the server beforehand.
Fix the power cord or interface cable with cable ties.
Make sure that no pressure is applied on the plug of power cord.
Connecting to Uninterruptible Power Supply (UPS)
To connect the power cord of the server to a UPS, use the connector output on the rear of the UPS. For details,
refer to the manual supplied with the UPS.
Universal Serial Bus (USB) port
Example
Option slot
Overload protection
reset button
Connector outputs
TVSS device connector
Computer interface port (COM)
Input connector
(NEMA5-15P)
Voltage sensitivity setting button
When the power cord is connected to a UPS, the BIOS settings may need to be changed in order to link the
server with the power supply from the UPS.
To change the settings, select Server and then AC-LINK in BIOS Setup Utility, and change the displayed
parameters. Select Power On to perform automatic operations by using the UPS. For details, see Chapter 2 (1.
Details of System BIOS) in "Maintenance Guide".
120
Express5800/R120e-1M
User’s Guide
NEC Express5800 Series
Express5800/R120e-1M
Setup
This chapter describes how to set up the server.
1. Turning on the Server
POST (Power-On Self-Test) is explained in this section.
2. BIOS Setup Utility (SETUP)
You can customize the BIOS settings by following the instructions in this section.
3. EXPRESSSCOPE Engine 3
EXPRESSSCOPE Engine 3 provides useful features through Baseboard Management Controller (BMC).
4. EXPRESSBUILDER
EXPRESSBUILDER helps you to install Windows and maintain the server.
5. Installing Software Components
You can install Windows and bundled software by following the instructions in "Installation Guide
(Windows)".
6. Turning off the Server
Turn off power when not using the server.
Express5800/R120e-1M
User’s Guide
121
Chapter 3 Setup
1.
1. Turning on the Server
Turning on the Server
Pressing POWER Switch at the front of the server turns on the server.
Turn on the server by using the following procedure.
• Do not power on the server before amber POWER LED is unlit.
Tips
• Wait for at least 30 seconds before turning on the server after turning off the
server.
1.
Turn on the peripheral devices and display unit.
Note
If the power cord is connected to power control system such as an Uninterruptible
Power Supply (UPS), make sure that the power control system is turned on.
2.
Remove Front Bezel.
3.
Press POWER Switch at the front of the server.
POWER LED is turned on green and after a while, logo appears on the display.
Important
Do not connect or disconnect USB device while POST is running.
POWER Switch
While logo is being displayed, the self-diagnostic program (POST) runs and diagnoses the hardware. For
details, see Chapter 3 (1.1 POST).
122
Express5800/R120e-1M
User’s Guide
Chapter 3 Setup
1.1
1. Turning on the Server
POST
POST (Power-On Self-Test) is a self-diagnostic program stored in the server as standard. POST
automatically runs immediately after the server is turned on and checks the motherboard, memory, and
processor (CPU). POST also displays the start-up messages of different utilities during the operation.
Usually, you do not need to check the contents of POST. However, check messages displayed at POST
in the following cases.
• When introducing a server
• If you suspect a failure
• When you hear beep many times during the time between power ON and OS startup
• When any error message is displayed
1.1.1
POST sequence
Explains how POST runs in order.
1.
When the server is turned on, POST starts, and an initialization
message is displayed. The message to tell initialization of
a memory and a PCI device. After an initialization message
was displayed, a logo appears on the screen.
• Keyboard becomes operable after the logo appears.
Note
• While an initialization message is displayed, a screen is sometimes switched
over to the screen by which nothing is displayed (black screen) several times.
It’s no problem for operation.
• An initialization message isn't sometimes displayed by the occasion with which
an option VGA controller was connected and setting of a BIOS setup utility
(SETUP).
• An initialization message isn't displayed on the console redirection screen of a
serial port.
2.
If Enabled is specified for Password On Boot in Security menu of SETUP, you will be prompted to
enter password after the logo is displayed. If you enter the incorrect password three times consecutively,
POST aborts. (You can no longer proceed.) In this case, power off the server, and power it on.
Important
3.
Do not set a password before OS is installed.
If <Esc> key is pressed, the logo disappears and the details of POST are displayed.
Tips
If Quiet Boot is Disabled from Boot menu in BIOS settings, the logo is not
displayed without requiring <ESC> key to be pressed.
4.
POST displays several types of message. These messages let you know that the installed CPU or
connected keyboard and mouse are detected.
5.
After a while, the following message is displayed on the screen.
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
Express5800/R120e-1M
User’s Guide
123
Chapter 3 Setup
1. Turning on the Server
By pressing the designated function key following messages, you can call the functions below upon
completion of POST.
<F2> key: Run BIOS Setup Utility (SETUP). For information on the SETUP, see Chapter 2 (1. Details
of System BIOS) in "Maintenance Guide".
<F3> key:
Run EXPRESSBUILDER from Internal Flash Memory (optional). For information on
EXPRESSBUILDER, see Chapter 3 (4. EXPRESSBUILDER).
• If the optional Internal Flash Memory is not installed in the system, <F3> key
Note
message will not be displayed.
• <F3> key must be pressed within 5 seconds of the message being displayed.
• Note that the server will not boot from Internal Flash Memory even if it is
specified to do so by pressing <F3> key, as long as a bootable CD/DVD-ROM is
set on the drive.
<F4> key:
Run Offline Tools. For information on Offline Tools, see Chapter 1 Maintenance (9. Offline
Tools) in "Maintenance Guide".
<F12> key: Boot from network.
6.
If a controller which has its dedicated BIOS such as a RAID Controller board is installed, a message
that prompts you to start the dedicated utility to set each board is displayed.
Example: If an optional RAID Controller is installed
Press <Ctrl> <H> for Web BIOS
The utility starts by pressing <Ctrl> + <H> keys.
For details on the utility, refer to the manual supplied with each optional board.
Depending on the configuration, the message "Press Any Key" might appear to prompt a key entry.
This is a behavior of the BIOS of the optional board. Continue to operate after checking the manual
of the optional board.
7.
1.1.2
The OS starts when POST is completed.
POST error messages
When POST detects an error, it displays an error message on the screen or beeps for some errors. For
descriptions of error messages, causes, and countermeasures, see Chapter 3 (1. POST Error Message) in
"Maintenance Guide".
Note
Take notes on the indication displayed on display unit before consulting with your
sales representative. Alarm messages are useful information for maintenance.
124
Express5800/R120e-1M
User’s Guide
Chapter 3 Setup
2.
2. BIOS Setup Utility (SETUP)
BIOS Setup Utility (SETUP)
This section describes how to configure Basic Input Output System (BIOS).
Before you install the server and add or remove optional devices, make sure you have read and understood
this section to configure properly.
2.1
Overview
BIOS Setup Utility (SETUP) is a utility to do basic hardware settings. This utility is installed in a flash memory
in the server as standard and can be run without requiring a media for boot.
BIOS settings were configured with optimal settings before the server was shipped to you. Therefore, in most
of cases, you should not need to use the SETUP. Use only when the case applies to any of cases
described in Chapter 3 (2.4 Cases that Require Configuration).
2.2
2.2.1
Starting and Exiting SETUP Utility
Starting SETUP
Run POST following Chapter 3 (1.1.1 POST sequence).
After a while, the following message will be displayed on the lower left of the screen.
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
If you press <F2> key at this time, SETUP runs and displays Main menu upon completion of POST. (You can
also press <F2> key while NEC logo appears to display Main menu.)
Tips
If password is set, you will be prompted to enter password at next startup of
SETUP. (The timing when prompt appears depends on setting of password.)
Up to three password entries are accepted. If you enter incorrect password
consecutively three times, the system halts (you can no longer proceed).
In this case, power off the server once, then power it on.
2.2.2
Exiting SETUP
To exit SETUP after saving parameters, select Save & Exit → Save Changes and Exit.
To exit SETUP without saving parameters, select Save & Exit → Discard Changes and Exit.
Tips
To restore the default value, select Save & Exit → Load Setup Defaults.
(The default value might be different from the factory setting.)
Express5800/R120e-1M
User’s Guide
125
Chapter 3 Setup
2.3
2. BIOS Setup Utility (SETUP)
Description on On-Screen Items and Key Usage
This section shows display examples and how to control the key. Use the keyboard to work with SETUP.
Indicates the currently displayed menu
Indicates the menu
has submenus.
Help
Setting items
Parameters (highlighted when selected*)
*: Items that cannot be specified are dimmed.
† Cursor keys (<↑>, <↓>)
Select an item displayed on the screen. If characters of an item are highlighted, that means the item is
currently selected.
† Cursor keys (<←>, <→>)
Select menus including Main, Advanced, Security, Server, Boot, and Save & Exit.
† <−> key/<+> key
Change the value (parameter) of the selected item. You cannot use this key when a menu which has
on the left is selected.
† <Enter> key
Press this key to confirm the selected parameter.
† <Esc> key
Pressing this key takes you to the previous screen. If you keep pressing the key, the following window is
displayed. If you select Yes, SETUP closes without saving the changed parameters.
Quit without saving?
[Yes]
No
† <F1> key
Press this key to display help information. If you need help using SETUP, press this key. Press <Esc>
key to go back to the original screen.
126
Express5800/R120e-1M
User’s Guide
Chapter 3 Setup
2. BIOS Setup Utility (SETUP)
† <F2> key
If you press this key, the following window appears. If you select Yes, the previous parameter(s) are
restored.
Load Previous Values?
[Yes]
No
† <F3> key
If you press this key, the following window appears. If you select Yes, restore the parameters of the
currently selected item to the default setting. (This might be different from the parameters configured
before shipment.)
Load Setup Defaults?
[Yes]
No
† <F4> key
If you press this key, the following window appears. If you select Yes, the parameter you configured is
saved and SETUP closes.
Save configuration and exit?
[Yes]
No
Express5800/R120e-1M
User’s Guide
127
Chapter 3 Setup
2.4
2. BIOS Setup Utility (SETUP)
Cases that Require Configuration
Only if a case applies to any of following cases, use SETUP to change a parameter which was configured as
factory setting. Other than cases described below, do not change the settings. A list of SETUP parameters
and factory settings are described in Chapter 2 (1. Details of System BIOS) in "Maintenance Guide".
Category
Basic
Memory
To be changed
On/Off NumLock on power ON
Boot → Bootup Numlock State → ON
or OFF
On/Off the function to display
NEC logo during POST
Add or change DIMM
Boot → Quite Boot → Disabled
Use memory RAS feature
Advanced → Memory Configuration → Some of RAS features may not
be used depending on DIMM
Memory RAS Mode → change to RAS
configuration.
mode
Advanced → PCI Configuration → PCI XX is PCI slot number of the
installed option board
Device Controller and Option ROM
Settings → PCIXX Slot Option ROM
→ Disabled
Configurable on OS
By pressing <Esc> key, prevent
the display of the logo.
Advanced → Memory Configuration → After rebooting, Memory Retest
changes No automatically.
Memory Retest → Yes
Disable Option ROM Scan of
installed option board
Boot
Change the boot order of
devices
Boot → Boot Option Priorities →
Change the boot priority
Use remote power on feature
(via modem)
Advanced → Advanced Chipset
Configuration → Wake On Ring →
Enabled
Use remote power on feature
(via RTC alarm)
Advanced → Advanced Chipset
Configuration → Wake On RTC Alarm
→ Enabled
UPS
Powerlink
Remark
Main → System Date
Main → System Time
Optional
board
Security
128
Description
Change date and time
Use console redirection feature Advanced → Serial Port Configuration
→ Console Redirection Setting →
Change respective setting.
Set a password
Security → Administrator Password
→ Enter a password
(Set a password for Administrator first
and then User)
Restrict bootup by entering
password
Security → Password on Boot →
Enabled
When the server is supplied
with power from UPS, always
turn on the power.
Server → Power Control
Configuration → AC-LINK → Power
On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Keep the power OFF even
when UPS supplies power.
Server → Power Control
Configuration → AC-LINK → Last
State
Server → Power Control
Configuration → AC-LINK → Stay off
Express5800/R120e-1M
User’s Guide
When you use
EXPRESSBUILDER, set
CD/DVD to the highest priority.
There are two types of
password; Administrator and
User.
Settings for User password is
limited compared to for
Administrator.
Can be selected when
password is set.
Chapter 3 Setup
2. BIOS Setup Utility (SETUP)
Password
If you have set a password, a message prompt you to enter password will be displayed from the next time.
Enter password [
]
You can attempt password entry up to 3 times. If you entered a wrong password 3 times, operation stops.
(You cannot operate further.) Turn off the power.
Saving changes
If you finish configuration, select Save & Exit and then Save Changes and Exit to save changes and exit.
If you wish to exit without saving the changed parameters, select Save & Exit and then Discard Changes
and Exit.
Or if you wish to restore the setting to default values, select Save & Exit and then Load Setup Defaults.
(The default value might be different from the factory setting.)
Express5800/R120e-1M
User’s Guide
129
Chapter 3 Setup
3.
3. EXPRESSSCOPE Engine 3
EXPRESSSCOPE Engine 3
3.1
Overview
EXPRESSSCOPE Engine 3 provides a variety of features using BMC (Baseboard Management Controller),
which is a system management LSI.
See EXPRESSSCOPE Engine 3 User's Guide for detailed information.
EXPRESSSCOPE Engine 3 monitors the power supply unit, fans, temperature, and voltage of the server. If
you have the management LAN port connected to the network, you can remotely perform the following over a
web browser or SSH client:
•
•
•
Manage the server
Remotely control the keyboard, video, and mouse (KVM)*
Remotely access a CD/DVD/floppy disk/ISO image/USB memory*.
* To enable this feature, the optional license for remote management (N8115-04) is required.
To actualize these functions, virtual USB mass storage (Remote FD, Remote CD/DVD, Remote USB Memory,
or Virtual Flash) is always connected as USB mass storage.
3.2
EXPRESSSCOPE Engine 3 Network Configuration
To enable EXPRESSSCOPE Engine 3 to be used via network, network configuration is required. Below is an
example of the configuration procedure which enables EXPRESSSCOPE Engine 3 to be used via a web
browser.
1.
Run POST following Chapter 3 (1.1.1 POST sequence). Wait until the following message appears on
the lower left of the screen.
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
2.
If you press the <F4> key at this time, Offline Tool starts upon completion of POST. You can also press
the <F4> key while the NEC logo is being displayed to open the Off-line TOOL MENU screen.
3.
The keyboard selection screen appears. Select your keyboard type.
After that, the Off-line TOOL MENU screen appears. On this screen, specify the network settings for
EXPRESSSCOPE Engine 3.
130
Express5800/R120e-1M
User’s Guide
Chapter 3 Setup
4.
3. EXPRESSSCOPE Engine 3
When the Off-line TOOL MENU appears, select BMC Configuration, BMC Configuration, Network,
and then Property.
Tips
If Shared BMC LAN is enabled, Web feature, remote media/KVM feature, or
command line interface feature may be interrupted. In this case, wait for a while,
and connect with network again.
5.
If Property is selected, the following screen is displayed. On this screen, specify Enable if you want to
use DHCP, or specify IP Address/Subnet Mask if you do not use DHCP.
6.
Connect the LAN cable to the management LAN connector in order to connect to the network. It will be
available for use if you access EXPRESSSCOPE Engine 3 via Web browser from PC for management
according to the setting.
Express5800/R120e-1M
User’s Guide
131
Chapter 3 Setup
4.
4. EXPRESSBUILDER
EXPRESSBUILDER
EXPRESSBUILDER helps you to install Windows or maintain the server.
4.1
Features of EXPRESSBUILDER
EXPRESSBUILDER provides the following features.
Features
Descriptions
Setup
Installs Windows on your server. Easily completes the process from RAID
(Windows reinstallation)
configuration to installation of applications. To use this feature, select OS
installation in the menu after boot.
Bundled software*
Stores various bundled software (such as NEC ESMPRO Agent).
Diagnoses your server system. To use this feature, select Tool menu in
Maintenance
the menu after boot.
Stores various documents (including "User’s Guide", "Installation Guide"
Documents*
and "Maintenance Guide").
* Documents and some software components are not stored in N8115-05 Internal Flash Memory (option).
4.2
Starting EXPRESSBUILDER
Follow the procedures below to start EXPRESSBUILDER.
EXPRESSBUILDER DVD:
Set the DVD on the drive and either turn on the server or restart the server by pressing <Ctrl> + <Alt> +
<Delete>. EXPRESSBUILDER is booted from DVD.
If you want to install any bundled software or see documents, set the DVD to a computer running
Windows. Autorun menu appears automatically.
N8115-05 Internal Flash Memory (option):
Press <F3> key during POST. Make sure that the media was removed from the drive when using this
option.
See Chapter 2 (5. Details of EXPRESSBUILDER)in Maintenance Guide for detail.
132
Express5800/R120e-1M
User’s Guide
Chapter 3 Setup
5.
5. Installing Software Components
Installing Software Components
Continue to install software components such as OS.
See the instructions below.
•
Installation Guide (Windows)
Express5800/R120e-1M
User’s Guide
133
Chapter 3 Setup
6.
6. Turning Off the Server
Turning Off the Server
Turn off the server by using the following procedure. If the power cord of the server is connected to a UPS,
refer to the documentation supplied with the UPS or the documentation for the application controlling the UPS.
1.
Shut down the OS.
2.
The server automatically turns off after the OS shuts down.
Confirm that POWER LED is OFF.
3.
Turn off peripheral devices.
Tips
Hibernate function of Windows Server cannot be used. Do not set Hibernate at
Windows shutdown.
134
Express5800/R120e-1M
User’s Guide
NEC Express5800 Series
Express5800/R120e-1M
Appendix
1.
Specifications
2.
Interrupt Lines
Express5800/R120e-1M
User’s Guide
135
Chapter 4
Appendix
1.
1. Specifications
Specifications
Product name
N code
CPU
CPU
Clock speed
Number of CPUs,
standard/maximum
3rd cache
Number of cores (C) /
Number of
threads (T) per CPU
Chipset
Capacity,
standard/maximum
Memory module
Memory
Auxiliary
storage
Maximum operating
frequency
Error check, correction
Memory sparing
Memory mirroring
Internal
(standard)
Hard disk
Internal
drive
(maximum)
Hot swap
Interface / RAID level
Optical disk drive
FDD
Expansion bay
Expansion
slots
Supported slots
Graphics
Chip/VideoRAM
Graphic display /
resolution
Interface
Power supply unit
Redundant power supply
Redundant fan
External dimensions (width × depth ×
height)
Weight (Standard/ Max.)
Power
consumption High-load state
(100V at
maximum
40°C environment
configuration)
Environmental
Operating
requirements
Storage
Temperature/Humidity
Main accessories
Installed OS
Supported OSs
N8101-675F
N8101-676F
Intel ®Xeon® processor
E5-2609 v2
E5-2620 v2
2.50GHz
2.10GHz
Express5800/R120e-1M
N8100-2073F
N8101-677F
N8101-678F
N8101-679F
N8101-680F
E5-2630 v2
2.60GHz
E5-2637 v2
3.50GHz
E5-2640 v2
2.00GHz
E5-2630L v2
2.40GHz
1/2
10M
15M
4C/4T
6C/12T
20M
4C/8T
8C/16T
Intel® C602-J chipset
Not pre-installed /Unbuffered DIMM: 64GB (16x 4GB),
Registered DIMM: 384GB (24x 16GB),
Load Reduced DIMM: 1536GB (24x 64GB)
DDR3L-1600 Unbuffered DIMM (4GB),
DDR3L-1600 Registered DIMM (2/4/8/16GB), DDR3L-1866 Registered DIMM (8/16GB),
DDR3L-1333 Load Reduced DIMM (32GB), DDR3L-1600 Load Reduced DIMM (64GB)
1333MHz
1600MHz
1866MHz
1600MHz
ECC, x4 SDDC, Memory LockStep (x8 SDDC)
Supported
Supported
-
2.5-inch HDD: SATA 8TB (8x 1TB), SAS 9.6TB (8x 1.2TB),
2.5-inch SSD: SAS 3.2TB (8x 400GB)(with optional HDD cage installed)
Supported
SATA 3, 6Gb/s : RAID 0/1/5/6/10/50/60 (Option)
SAS 6Gb/s : RAID 0/1/5/6/10/50/60 (Option)
Internal or external drive (option) *1
Option: Flash FDD (1.44MB) *2
None
1x PCI EXPRESS 3.0 (x16 lane, x16 socket) (Full hight, length 220 mm)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Low profile, length 220 mm)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Dedicated to RAID Controller)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Dedicated to LAN riser card)
Embedded management controller chip / 32 MB
16,770,000 colors: 640x840, 800x600, 1,024x768, 1,280x1,024
9x USB 2.0 (2x front, 4x rear, x3 internal), 2x Analog RGB (Mini D-sub15-pin, 1x front, 1x rear),
1x Serial port (RS-232C compliant / D-sub 9-pin, Serial port A, 1x rear, optional port can be used (up to two
ports in total)).
2x 1000BASE-T LAN connector (1000BASE-T/100BASE-T/10BASE-T supported, RJ45, 2x rear),
1x Management LAN connector (100BASE-T/10BASE-T supported, RJ45, 1x rear)
Not pre-installed / 450W or 800W 80 Plus® Platinum compliant (bipolar grounded outlet) (hot-plug available)
maximum: 2 units) 100/200 VAC ± 10%, 50/60 Hz ± 3 Hz
Supported (option, hot-plug available)
Supported (standard, hot-plug unavailable)
439.8mm x 722.0mm x 43.4mm (front bezel/ protrusions/ inner rails excluded)
482.4mm x 757.0mm x 44.4mm (front bezel/ protrusions/ inner rails included)
15.2 kg / 23 kg (including rails)
584VA/583W
584VA/583W
584VA/583W
544VA/543W
684VA/683W
614VA/613W
680VA/670W
680VA/670W
680VA/670W
640VA/630W
780VA/770W
710VA/700W
10 to 40°C / 20 to 80%,
–10~55°C / 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager) (Windows), NEC ESMPRO Agent, User’s Guide (electronic
document) included), Getting Started, one-touch rack rail
-
Microsoft Windows Server 2008 Standard (RTM, SP2 or later), Microsoft Windows Server 2008 Enterprise
(RTM, SP2 or later),
Microsoft Windows Server 2008 Standard (x64) (RTM, SP2 or later), Microsoft Windows Server 2008
Enterprise (x64) (RTM, SP2 or later),
Microsoft Windows Server 2008 R2 Standard, Microsoft Windows Server 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard, Microsoft® Windows Server® 2012 Datacenter,
VMware ESXi™ 5.1 update 1,
Red Hat® Enterprise Linux® 5.9 or later, Red Hat® Enterprise Linux® 5.9 or later (EM64T)
Red Hat® Enterprise Linux® 6.4 or later, Red Hat® Enterprise Linux® 6.4 or later (x86_64)
*1
If you do not intend to install an internal DVD-ROM or an internal DVD SuperMULTI in all systems, prepare at least one external DVD-ROM per
*2
Prepare this if required. For the principal uses of a Flash FDD, refer to the notes on Flash FDD in the Maintenance Guide.
system for maintenance and OS reinstallation purposes.
136
Express5800/R120e-1M
User’s Guide
Chapter 4
Appendix
1. Specifications
Product name
N code
CPU
CPU
Clock speed
Number of CPUs,
standard/maximum
3rd cache
Number of cores (C) /
Number of
threads (T) per CPU
Chipset
Capacity,
standard/maximum
Memory module
Memory
Auxiliary
storage
Maximum operating
frequency
Error check, correction
Memory sparing
Memory mirroring
Internal
(standard)
Hard disk
Internal
drive
(maximum)
Hot swap
Interface / RAID level
Optical disk drive
FDD
Expansion bay
Expansion
slots
Supported slots
Graphics
Chip/VideoRAM
Graphic display /
resolution
Interface
Power supply unit
Redundant power supply
Redundant fan
External dimensions (width × depth ×
height)
Weight (Standard/ Max.)
Power
High-load state
consumption
(100V at
40°C environment
maximum
configuration)
Environmental
Operating
requirements
Temperature/Humidity
Storage
Main accessories
Installed OS
Supported OSs
N8101-681F
N8101-682F
Intel ®Xeon® processor
E5-2650 v2
E5-2660 v2
2.60GHz
2.20GHz
Express5800/R120e-1M
N8100-2073F
N8101-683F
N8101-684F
N8101-685F
N8101-686F
E5-2670 v2
2.50GHz
E5-2697 v2
2.70GHz
E5-2695 v2
2.40GHz
E5-2690 v2
3.00GHz
1/2
20M
25M
30M
8C/16T
10C/20T
12C/24T
Intel® C602-J chipset
Not pre-installed /Unbuffered DIMM: 64GB (16x 4GB),
Registered DIMM: 384GB (24x 16GB),
Load Reduced DIMM: 1536GB (24x 64GB)
DDR3L-1600 Unbuffered DIMM (4GB),
DDR3L-1600 Registered DIMM (2/4/8/16GB), DDR3L-1866 Registered DIMM (8/16GB),
DDR3L-1333 Load Reduced DIMM (32GB), DDR3L-1600 Load Reduced DIMM (64GB)
1866MHz
ECC, x4 SDDC, Memory LockStep (x8 SDDC)
Supported
Supported
-
2.5-inch HDD: SATA 8TB (8x 1TB), SAS 9.6TB (8x 1.2TB),
2.5-inch SSD: SAS 3.2TB (8x 400GB)(with optional HDD cage installed)
Supported
SATA 3, 6Gb/s : RAID 0/1/5/6/10/50/60 (Option)
SAS 6Gb/s : RAID 0/1/5/6/10/50/60 (Option)
Internal or external drive (option) *1
Option: Flash FDD (1.44MB) *2
None
1x PCI EXPRESS 3.0 (x16 lane, x16 socket) (Full hight, length 220 mm)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Low profile, length 220 mm)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Dedicated to RAID Controller)
1x PCI EXPRESS 3.0 (x8 lane, x8 socket) (Dedi
Embedded management controller chip / 32 MB
16,770,000 colors: 640x840, 800x600, 1,024x768, 1,280x1,024
9x USB 2.0 (2x front, 4x rear, x3 internal), 2x Analog RGB (Mini D-sub15-pin, 1x front, 1x rear),
1x Serial port (RS-232C compliant / D-sub 9-pin, Serial port A, 1x rear, optional port can be used (up to two
ports in total)).
2x 1000BASE-T LAN connector (1000BASE-T/100BASE-T/10BASE-T supported, RJ45, 2x rear),
1x Management LAN connector (100BASE-T/10BASE-T supported, RJ45, 1x rear)
Not pre-installed / 450W or 800W 80 Plus® Platinum compliant (bipolar grounded outlet) (hot-plug available)
maximum: 2 units) 100/200 VAC ± 10%, 50/60 Hz ± 3 Hz
Supported (option, hot-plug available)
Supported (standard, hot-plug unavailable)
439.8mm x 722.0mm x 43.4mm (front bezel/ protrusions/ inner rails excluded)
482.4mm x 757.0mm x 44.4mm (front bezel/ protrusions/ inner rails included)
15.2 kg / 23 kg (including rails)
614VA/613W
614VA/613W
654VA/653W
684VA/683W
684VA/683W
654VA/653W
710VA/700W
710VA/700W
750VA/740W
780VA/770W
780VA/770W
750VA/740W
10 to 35°C / 20 10 to 40°C / 20
to 80%,
to 80%,
–10~55°C / 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager) (Windows), NEC ESMPRO Agent, User’s Guide (electronic
document) included), Getting Started, one-touch rack rail
-
Microsoft Windows Server 2008 Standard (RTM, SP2 or later), Microsoft Windows Server 2008 Enterprise
(RTM, SP2 or later),
Microsoft Windows Server 2008 Standard (x64) (RTM, SP2 or later), Microsoft Windows Server 2008
Enterprise (x64) (RTM, SP2 or later),
Microsoft Windows Server 2008 R2 Standard, Microsoft Windows Server 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard, Microsoft® Windows Server® 2012 Datacenter,
VMware ESXi™ 5.1 update 1,
Red Hat® Enterprise Linux® 5.9 or later, Red Hat® Enterprise Linux® 5.9 or later (EM64T)
Red Hat® Enterprise Linux® 6.4 or later, Red Hat® Enterprise Linux® 6.4 or later (x86_64)
10 to 40°C / 20 to 80%,
*1
If you do not intend to install an internal DVD-ROM or an internal DVD SuperMULTI in all systems, prepare at least one external DVD-ROM per
*2
Prepare this if required. For the principal uses of a Flash FDD, refer to the notes on Flash FDD in the Maintenance Guide.
system for maintenance and OS reinstallation purposes.
Express5800/R120e-1M
User’s Guide
137
Chapter 4
Appendix
2.
2. Interrupt Lines
Interrupt Lines
Interrupt lines are assigned as factory settings as shown below. Use this table as a reference when you add
optional devices.
•
Interrupt lines
As factory settings, interrupt lines are assigned as follows.
IRQ
0
1
Peripheral Device (Controller)
2
138
IRQ
System timer
Peripheral Device (Controller)
−
12
13
−
14
−
−
3
COM 2 serial port
15
4
5
6
COM 1 serial port
PCI
16
17
18
7
PCI
19
8
9
10
11
Real-time clock
Microsoft ACPI-Compliant System
PCI
Motherboard resource
20
21
22
23
−
Express5800/R120e-1M
SM Bus
Numeric data processor
VGA, LAN1
LAN2, SATA
−
−
USB
USB
USB
USB
User’s Guide