FLOW

FLOW
2012ofcobc.qxd:Layout 4
7/12/11
10:45 AM
Page 1
CT-D-I
DWYER INSTRUMENTS, INC. - Instrumentation & Control
www.dwyer-inst.com
Printed in U.S.A. 09/11 - INTL
2012
DWYER INSTRUMENTS, INC.
TO ORDER:
Phone: 219/879-8000
Fax: 219/872-9057
www.dwyer-inst.com
157:Layout 2
7/20/11
3:03 PM
Page 1
FLOW
TYPICAL APPLICATIONS
pages 158-160
TECHNICAL INFORMATION
page 161
Flowmeters,
Variable Area
pages 162-177
Flowmeters,
In-Line
pages 178-189
Flow Sensors,
In-Line
pages 190-191
Flowmeters,
Orifice Plate
pages 192-195
Sight Flow
Indicators
pages 196-198
Flowmeters
with Switch
page 199
Flow Switches,
Paddle
pages 200-206
Flow Switches,
Shuttle/Piston
pages 207-211
Flow Switches,
Thermal
pages 211-214
Flow Switches,
Piezo
page 215
Flow Transmitters,
In-Line
pages 215-216
Flow Transmitters,
Paddlewheel
pages 217-220
Flow Transmitters,
Turbine
pages 221-223
Flowmeters,
Totalizing
pages 224-226
Flow Transmitters,
Ultrasonic
pages 227-233
Flow Transmitters,
Thermal Dispersion
pages 234-235
Mass Flowmeters/
Controllers
pages 236-238
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
157
158:Layout 2
7/13/11
9:27 AM
Page 1
Switchbox
Chamber
Differential
Pressure Switch
Motor
Rate-Master®
Flowmeters
LO
Visi-Float®
Flowmeter
HI
Controls
037
Generator
Designers of a bio-medical incubator rely on a
Dwyer® flowmeter to control CO2 flow.
Flowmeters and/or differential pressure switches
monitor vital purge gas flow to motors, switchgear,
instruments.
This low temperature incubator with CO2 atmosphere is used in
bio-medical applications, such as short term blood work and long
term tissue culture studies. CO2 is introduced at a high initial
purge rate controlled by a timer. After the purge period, a Dwyer®
Visi-Float® flowmeter with a metering valve is utilized to adjust and
monitor the CO2 flow in cubic centimeters per minute. The VisiFloat® flowmeter provides the reliability and accuracy needed to
complement the host of high performance features designed into
this incubator.
To purge motors, generators, switchgear, and industrial instrument
cases, Dwyer® flowmeters are installed in the supply line to
indicate a flow of air, manufactured inert gas, or nitrogen to these
devices. The flowmeters (with valves) allow maintenance
personnel to set the flow quickly and recheck anytime to make
sure proper flow continues. A Dwyer® differential pressure switch
can also be used to monitor proper flow on a continuous basis
and provide a signal or alarm if purge gas flow fails. Such an
optional switch is shown above, monitoring proper flow of purge
gas to the switchbox as a function of pressure drop across the
flowmeter. The purging of electrical equipment in hazardous areas
may require more extensive control and monitoring devices.
Inlet Cyclone
Typical Applications
FLOW
Purge Gas Supply
Metering
Valve
Control Panel
Electronics Section
Sample Analyzer
Mini-Master®
Flowmeter
Sample
In Take
Vacuum Pump
Flowmeter
Air Moving
Section
Battery Pack
Optical
Section
Metering valves on Dwyer® flowmeters control air/gas
intake on permanent air pollution analyzers.
Operator uses Mini-Master® flowmeter to verify air
flow into portable dust monitor.
Regulations regarding air pollution levels require continuous
monitoring a source and ambient pollutants in areas where
noxious gases are generated. Ambient air quality samplers utilize
either Visi-Float® or Rate-Master® flowmeters to establish the
proper flow of sample or carrier gases into the analyzer. Top
mounted metering valves are recommended for flowmeters used
in vacuum service to maintain specified accuracy.
The small size, accuracy, and low cost of the Dwyer® Mini-Master®
Series flowmeter lends itself perfectly to use in this portable,
battery-operated dust monitor. Using a light scattering electronic
sampler, a small vacuum pump draws air through the flowmeter
into the sampling chamber, and the flowmeter verifies the proper
volume of sample air flow. Readout is digital and directly in dust
weight per cubic meter of air.
158
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
159:Layout 2
7/13/11
9:32 AM
Page 1
Bleed Fittings
®
Capsuhelic
Differential
Pressure Gage
(Brass Option)
Cooling Tower
LO
HI
Alarm
Flotect®
Switch
Series DS-300
Averaging Pitot Tube
Circulating
Pump
Air Conditioning
Unit
Water Flow
Condenser
Brass body gage measures water flow rates.
Large air conditioning and refrigeration systems which include
water cooled condensers require that the water must circulate
through the condenser and cooling tower in sufficient volume
before the compressor is started. Here the W.E. Anderson®
Flotect® flow switch is connected to the compressor control circuit
to prevent starting or to shut down the compressor control circuit
if the flow of cooling water falls below that required for proper
operation. A dual Flotect® switch (available as an option) will also
trigger a remote alarm to signal the operator of the shutdown as
soon as it occurs.
Typical Applications
Flotect® Switch
Storage Tank
Supply
Return
Check Valve
Midwest
Sight Flow
Indicator
Main Pump
Valve
Standby Pump
Check Valve
Portable
Tank
Check Valve
When main pump fails, Flotect® flow switch transfers
to standby pump to maintain vital fluid circulation.
W.E. Anderson® Midwest Sight Flow Indicator reveals
flow or stoppage.
When proper fluid circulation in a system is critical, the W.E.
Anderson® Flotect® flow switch will automatically start a standby
pump should the main pump fail. The flow in the main path of the
parallel system illustrated keeps the Flotect® flow switch in an
open position. When the main pump fails, the flow will cease. The
flow switch then closes, starting the standby pump.
In this gravity feed system delivering liquid fertilizer to portable
tanks, a Midwest Model 100 sight flow indicator was installed. The
operator can see the rotating vanes to check for adequate flow at
any time.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
FLOW
A Dwyer® brass body Capsuhelic® differential pressure gage,
required for water service to prevent corrosion damage to the
gage, is used in conjunction with a Dwyer® Series DS-300
averaging Pitot tube. The Capsuhelic® gage provides a basic
method of measuring water flow rates. As a guide in selecting the
appropriate Capsuhelic® gage range, the designer can consult
data provided with the DS-300 averaging Pitot tube. This relates
differential pressure in inches of water column to the water flow in
gallons per minute for the pipe size involved. The gage can be
calibrated directly in GPM if desired. Bleed fittings installed in the
top ports of the gage are recommended to facilitate removal of air
from the system.
Flotect® flow switch ensures cooling water
circulation before air conditioning compressor motor
starts.
159
160:Layout 2
7/13/11
9:33 AM
Page 1
Visi-Float®
Dual Column
Flow
Rate-Master®
Flowmeters
Furnace
Control Panel
Conveyor
Patient Mask
O2
Tank
Flows of air and gases used in a special furnace are
controlled by Dwyer® flowmeters.
Durable dual-column flowmeter adds value for
physicians and oral surgeons.
A total of eleven Dwyer® Rate-Master® flowmeters function in the
design of this sophisticated conveyor belt furnace used in
manufacturing electronic devices. The flowmeters provide precise
adjustment and monitoring of the flows of air and gases into the
various portions of the furnace, which allow it to perform different
operations, such as decarburizing and oxidizing, metallic package
sealing, glass package sealing, and glass-to-metal sealing.
Physicians and oral surgeons who use anesthesia or analgesia in
their offices on an occasional basis require a system that is
reliable but small and portable. One such system employs special
Dwyer® dual-column Visi-Float® flowmeters to meter and monitor
precise flows of nitrous oxide and oxygen to the patient. In
addition to meeting the performance level demanded by this
application, the Visi-Float® flowmeters are durable and attractive
complements to this important and visible medical device.
Typical Applications
FLOW
N2O
Tank
HI
Clear Plastic Cover
Magnehelic®
Gage
LO
Static Pressure Taps
Flow
Duct
Visi-Float®
Flowmeter
Orifice Plate
Bubbler
Column
Test Tank
Measuring air velocity with an orifice plate.
Controls
In this set-up, the Magnehelic® gage measures higher air
velocities as a function of the pressure drop across a sharp-edged
orifice plate in the pipe. The pressure drops can be converted to
air velocity using orifice plate data supplied by the manufacturer.
Details regarding available sizes, ranges, installation, and
limitations are available from orifice plate manufacturers and from
standard handbooks. A Dwyer® Durablock® inclined manometer
or Photohelic® differential pressure switch/gage can also be used.
In addition to the visual reading gage, the Photohelic® switch/gage
provides an alarm signal or shutdown control function. Pressure
sensing taps should be located on the side or top of the pipe or
duct to prevent condensation from draining into sensing lines or
gages.
Salt corrosion test cabinet includes a Dwyer®
flowmeter for adjustment of bubbler air flow.
Prior to atomizing a heated salt solution to produce a fog inside
this corrosion test cabinet, compressed air is bubbled through a
heated water column to properly heat and humidify the air. A
Dwyer® Visi-Float® VFA flowmeter, as part of the system, provides
precise adjustment of the bubbler air flow to meet test standards.
160
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
161:Layout 2
7/13/11
9:34 AM
Page 1
CONVERSION CURVES FOR GASES
GAS PRESSURE PSIG BELOW ATMOSPHERE
-14
10
-12
-10
-8
-6
-4
-2
0
4
8
6
8
OBSERVED FLOWMETER READING
10
15
7
20
6
30
40
5
60
80
100
4
3
2
GAS PRESSURE PSIG ABOVE ATMOSPHERE
2
9
1
1
2
8
9
0.4
FLOW
6
7
3
4
5
ACTUAL GAS FLOW CORRECTED FOR PRESSURE*
SPEClFIC GRAVITY OF GAS (REFERRED TO AIR) 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.9 0.8 0.7
0.6
0.5
10
0
10
0.3
0.2
9
7
Technical Information
OBSERVED FLOWMETER READING
8
0.1
6
5
4
3
2
1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
EQUIVALENT GAS FLOW CORRECTED FOR SPECIFIC GRAVITY-STD. COND.*
If more convenient, approximate correction factors may be determined
using the following formulas.
A. Pressure: Q2 = Q1 X
P1 X T2
P2 X T1
where: Q1= Actual or Observed Flowmeter Reading
Q2 = Standard Flow Corrected for Pressure and Temperature
P1 = Actual Pressure (14.7 psia + Gage Pressure)
P2 = Standard Pressure (14.7 psia, which is 0 psig)
T1 = Actual Temperature (460 R + Temp °F)
T2 = Standard Temperature (530 R, which is 70°F)
17
18
19
20
B. Specific Gravity: Q2 = Q1 X
1
S.G.
where: Q1 = Observed Flowmeter Reading
Q2 = Standard Flow Corrected for Specific Gravity
1 = Specific Gravity of Air
S.G.= Specific gravity of gas being used in flowmeter originally calibrated for air.
Note: The corrections shown in the curves and in the formulas are for variations in specific gravity
and internal pressure* only. Further correction may be necessary for variations in viscosity and
changes in type of flow from laminar to turbulent or vice versa. This is particularly true in the case
of extremely low flows of the lighter gases. Nevertheless these charts and correction factors can
be quite useful when dealing with small changes in pressure* and specific gravity.
*Measured at discharge on all but TMV units. Inlet pressure on TMV models.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
161
162:Layout 2
7/13/11
9:34 AM
Page 1
Series
MM
®
Mini-Master Flowmeters
Used to Indicate or Manually Control Air or Water
2-1/2 [63.50]
1-31/32
[50.01]
ø5/16
[7.94] TYP
1-1/2 [38.10]
3-3/4
[95.25]
3
[76.20]
3/8 [9.53]
3/4
[19.05]
1-3/8 [34.93]
1-29/32
[48.42]
2-27/64 [61.52]
1
[25.40]
FLOW
C
B
A
A. Standard Model MMA
B. Standard Model MMA with field configurable valve, bottom mount
C. Standard Model MMA with field configurable valve, top mount
1/4
[6.15]
O.D. TUBES
1/2
[12.70]
3/4
[20.19]
OUTLET
2-1/16
[52.37]
Flowmeters, Variable Area
2-5/8
[66.68]
INLET
7/8
[22.23]
Model MMF-50-PV
1-1/2˝ scale, with
metering valve, knob.
Model MMF-10
with 1-1/2˝ scale,
no valve.
5/16
[7.92]
3/4
13/32
[10.36] [19.05]
Model MMF-10-TMV with
top-mounted valve-for
vacuum service. Use
screwdriver to adjust.
15/16
[23.98]
Despite its compactness, the MMA flowmeter features a 2˝ scale which
combined with precision molding, enables highly repeatable readings to be
made to within ±4% accuracy.
Offering advanced features at low cost, the Series MM flowmeters are ideal
for a wide range of OEM and user applications in medical equipment, air
samplers, gas analyzers, pollution monitors, chemical injectors, cabinet
purging, etc.
Where a compact flowmeter is required to measure small volume air flows, the
Model MMF is recommended. Easy to mount, they require a minimum of panel
space. A white back on the flow tube makes the ball float easy to see. The 1-1/2˝
scale is highly visible and easy to read. Scale graduations are printed on
aluminum alongside the flow tube (not on it), so the position of ball float is
instantly visible.
The standard Model MMA flowmeter is suitable for both gas and liquid
applications. It can be configured by the user with the parts provided to have
non-removable top or bottom front mounted metering valves or no valve at all.
The transparent nylon material provides high chemical resistance, low moisture
absorption and is transparent to facilitate routine inspection. Using the
assembly key provided, the flowmeter can be disassembled anytime for cleaning
or reconfiguration. In OEM quantities, ultrasonically welded caps or
interchangeable mold cores enable production of the MMA flowmeter with a low
profile or flat front surface where no valve is required.
The Model MMF’s bezel type mounting is modern, attractive and quickly
installed from the front of instrument panel. Two 1/4˝ O.D. mountingconnection tubes are integrally molded with flowmeter body. They can be back
connected to flexible rubber or plastic tubing and held in place with two spring
retainers which are furnished. If preferred, connections may be made to metal
or rigid plastic tubing with a double compression fitting or nylon tube union
such as Dwyer Part No. A-328.
The MMA is practically unbreakable, mounts easily, and is easy to read. Two
5/16˝ O.D. mounting — connection tubes permit quick push-on connection of
rubber or plastic tubing. A bottom clip for “stand up” mounting is also provided.
Excellent repeatability and ±10% accuracy make the MMF flowmeter an
excellent value at its low cost.
162
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
163:Layout 2
7/13/11
9:37 AM
Page 1
Model MMA
Model MMF
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Body: Nylon 12; O-rings: Buna-N (optional materials
available); Float: Black glass, K monel, stainless steel, tungsten carbide.
Temperature Limit: 130°F (54°C).
Pressure Limit: 100 psi (6.9 bar) with compression fitting. 50 psi
(3.4 bar) with tubing clamp.
Accuracy: ±4% full scale.
Process Connection: 5/16˝ O.D. for push on rubber or plastic tubing
with provided spring tubing clamp. Connect to rigid tubing with double
compression fitting.
Weight: 1 oz (28.35 g).
How To Order
MMA-Range No.
Example: MMA-4
Series MMA with .5-5 SCFH Air Range
Range
No.
30
31
32
33
Model MMF Mini-Master® Ranges
Range SCFH Air
Range No.
.1-1
1
.2-2
2
1-10
10
5-50
50
10-100
100
Model MMF-X, Standard MMF
Model MMF-X-PV, MMF with bottom mount valve
Model MMF-X-TMV, MMF with top mount valve
A-328, 1/4˝ Union
35
36
37
38
Flowmeters, Variable Area
Range GPH
Water
.5-8
1-16
4-40
5-60
CC/Min. Water
5-50
10-150
20-200
50-500
LPM Water
.1-1.1
.25-2.5
.3-3.5
How To Order
MMF-Range No.-Valve
Example: MMF-1-PV
Series MMF with .1-1 SCFH Air Range with Valve
FLOW
Model MMA Mini-Master® Ranges
Range
Range Range Range
LPM Air No.
SCFH Air No.
.2-1.2
.5-2.5
20
3
.25-2.5 21
.5-5
4
.5-5
1-10
22
5
1-10
2-20
23
6
2.5-25
5-50
24
7
5-50
10-100
25
8
10-100 26
20-200
9
15-150 27
30-300
10
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Body: Styrene acrylonitrile; Float: Stainless steel,
black glass, nylon; Valve: Polyurethane.
Temperature Limit: 125°F (51°C).
Pressure Limit: 50 psi (3.4 bar). Valve option: 10 psi (0.6 bar).
Accuracy: ±10% full scale.
Process Connection: 1/4˝ O.D. for push on rubber or plastic tubing.
Connect to rigid tubing with compression fittings.
Weight: 0.5 oz (14.17 g).
40
41
42
Model MMA
A-327, 5/16˝ Union
MMA
tubing
connections
secured by clamp. “Standup”
mounting clip shown.
CALL TO ORDER:
Spring retainers on connection
tubes secure panel mounted
MMA. Compression union, P/N
A-327 shown.
U.S. Phone 219 879-8000
•
Model MMF mounts easily from
front of panel. Drill two 9/32˝ or
5/16˝ dia. holes in panel on 21/16˝ centers. Insert mounting
connector spuds. From rear, slide
on the two spring retainers
(furnished) and push on rubber or
plastic tubing.
U.K. Phone (+44) (0)1494-461707
•
Model
MMF
connections.
Connector at top, installed in
panel, has retainer and flexible
tubing in place. Connector at
bottom
shows
alternative
connection with metal or rigid
plastic tubing, using a double
compression nylon tube union
(as Dwyer Part No. A-328).
Australia Phone (+61) (0) 2 4272 2055
163
164:Layout 2
7/13/11
9:38 AM
Page 1
Series
RM
®
Rate-Master Flowmeters
Polycarbonate, Gas Flow from 0.05-1800 SCFH, Water Flows to 10 GPM
J
BACK
WIDTH
F
A
K
B
C
FLOW
E
D
G
I
FULL OPEN
L
H
Flowmeter Dimensions
Flowmeters, Variable Area
A
B
C
Model RMC-SSV 10˝
scale, 15-3/8˝ high
Model RMB-SSV 5˝
scale, 8-3/4˝ high
D
E
F
G
H
I
J
K
L
Model RMA-SSV 2˝
scale, 4-13/16˝ high
The Rate-Master® flowmeter line of direct reading precision flowmeters incorporates
many unique user features at moderate cost. These low cost flowmeters are ideal for
general use.
www.dwyer-inst.com
Model RMC
15 -1/8 (384.20)
12 -1/4 (311.20)
1/2 NPT CONN.
8-3/4 (222.30)
3/8-24 MTG. HOLES
1 (25.40)
2-3/4 (69.85)
2-1/2 (63.50)
1-7/16 (36.51)
1-31/32 (50.00)
2-1/2 (63.50)
2 (50.80)
15-3/8 (390.50)
2-1/4 (57.15)
Easy-to-Interchange bodies — Within a given Series Rate-Master® flowmeter bodies
can be instantly interchanged. Simply “unplug” the body from backbone and replace it with
another. “O” rings provide a tight seal on inlet and outlet. Piping remains undisturbed.
Interchangeability is useful where different scale ranges are sometimes required at the
same location in the laboratory or plant.
Construction assures accuracy — All Rate-Master® flowmeter bodies are injection
molded of tough, clear, shatter-proof polycarbonate plastic around a precision tapered pin.
The result is accurate and repeatable readings. The single piece plastic body is mounted to
a stainless steel back bone into which pipe thread inserts are welded to absorb piping
torque. Precision metering valves of brass or stainless steel (specify BV or SSV on order)
are available as an optional extra and permit precise flow adjustments. For vacuum
applications, Model RMA units are available with top mounted valves (specify TMV). The
small Series RMA models are accurate within ±4% of full scale reading; Series RMB within
±3%; large Series RMC within ±2%.
VISIT OUR WEBSITES:
Model RMB
8-1/2 (215.90)
6-7/16 (163.50)
1/4 NPT CONN.
3-15/16 (100.00)
1/4-20 MTG. HOLES
5/8 (15.88)
1-7/8 (47.63)
1-3/4 (44.45)
1 (25.40)
1-7/16 (36.51)
1-13/16 (46.04)
1-1/4 (31.75)
8-3/4 (222.30)
1-1/2 (38.10)
Installation is simple — The Rate-Master® Flowmeter can be neatly panel mounted to
keep flow tube centers in the same plane as the panel surface or surface mounted on the
panel by means of tapped holes in the backbone. When through-panel mounted, the bezel
automatically positions the instrument at the correct depth in the panel cutout. Surface
mounted units can also be held in place by the piping. All mounting hardware plus
installation and operating instructions are included.
Easy to read design — The direct reading scales eliminate troublesome conversions. The
scales are brushed aluminum, coated with epoxy and the graduations are on both sides of
the indicating tube. Special integral flow guides stabilize the float throughout the range
to keep it from hunting or wandering in the bore. The float is highly visible against a white
background.
164
Model RMA
4 -9/16 (115.90)
3 (76.20)
1/8 NPT CONN.
1-5/8 (41.28)
10-32 MTG. HOLES
3/8 (9.525)
1-1/16 (26.99)
1-3/16 (30.16)
11/16 (17.46)
61/64 (24.21)
1-3/8 (34.92)
3/4 (19.05)
4-13/16 (122.20)
1 (25.40)
Cleaning is easy — To release the plastic flowmeter body from the stainless steel
backbone, just remove four screws. Pipe thread flow connections remain undisturbed.
Remove the slide cover and the plug ball stop, clean the flow tube with soap and water and
reassemble. It’s that simple.
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
165:Layout 2
7/13/11
9:43 AM
Page 1
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Body: Polycarbonate; O-ring: Neoprene and Buna-N;
Metal parts: stainless steel (except for optional brass valve); Float:
stainless steel, black glass, aluminum, K monel, tungsten carbide
depending on range.
Temperature Limit: 130°F (54°C).
Pressure Limit: 100 psi (6.9 bar).
Accuracy: RMA: 4%; RMB: 3%; RMC: 2% of full scale.
Process Connection: RMA: 1/8˝; RMB: 1/4˝; RMC: 1/2˝ female NPT.
Weight: RMA: 4 oz (113.4 g); RMB: 13 oz (368.5 g); RMC: 39 oz
(1105.6 g).
How To Order
Series-Range No.(“X”)-Valve-Option
Example: RMA-2-SSV
Series RMA with .1-1 SCFH Air Range & Stainless Steel Valve
Model RMA
Model RMA-X, Standard RMA
Model RMA-X-BV, RMA with Brass Valve
Model RMA-X-SSV, RMA with Stainless Steel Valve
Model RMA-X-TMV, RMA with Top Mounted Valve
Model RMB
Model RMB-X, Standard RMB
Model RMB-X-BV, RMB with Brass Valve
Model RMB-X-SSV, RMB with Stainless Steel Valve
CAUTION
Dwyer® Rate-Master® flowmeters are designed to provide satisfactory
long term service when used with air, water, or other compatible media.
Refer to factory for information on questionable gases or liquids. Caustic
solutions, anti-freeze (ethylene glycol) and aromatic solvents should
definitely not be used.
Model RMC
Model RMC-X, Standard RMC
Model RMC-X-BV, RMC with Brass Valve
Model RMC-X-SSV, RMC with Stainless Steel Valve
Popular Ranges
Model RMC-10˝ Scale
Range
Range
SCFH Air
No.
5-50
101
10-100
102
20-200
103
40-400
104
60-600
105
100-1000
106
120-1200
107
200-1800
108
SCFM Air
1-10
121
2-20
122
4-30
123
Gal. Water
per hour
2-20
8-90
Gal.Water
per minute
.1-1
.2-2.2
.4-4
.8-7
1.2-10
OPTIONS & ACCESSORIES
Adjustable pointer flags – Red lined pointer
flags provide quick visual reference to a
required flow level. Of clear plastic, they snap
into place inside bezel and slide to desired level.
Top Mounted Metering Valves – Same
precision construction for vacuum applications.
RMA models only.
Specials – Special ranges, scales, mounting
arrangements, etc., are available on special
order, or in OEM quantities.
134
135
141
142
143
144
145
Model RMA-X-APF, Adjustable Pointer Flag for RMA Series
Model RMB-X-BPF, Adjustable Pointer Flag for RMB Series
Model RMC-X-CPF, Adjustable Pointer Flag for RMC Series
Model RKA, Regulator Kit for RMA Series
Model RK-RMB, Regulator Kit for RMB Series
*Accuracy ±8%
+Accuracy ±5%
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
165
Flowmeters, Variable Area
Model RMB-5˝ Scale
Range
Range
SCFH Air
No.
.5-5
49+
1-10
50
3-20
51
4-50
52
10-100
53
20-200
54
40-400
55
50-500
56
60-600
57
Gal. Water
per hour
1-12
82
1-20
83
4-40
84
10-100
85
SCFH & LPM
Air
1.2-10/0.6-5
50D
3-20/1.5-9.5
51D
4-50/2-23
52D
10-100/5-50
53D
20-200/5-95
54D
GPH & LPM
Water
1-12/0.06-0.76 82D
1-20/0.065-1.25 83D
10-100/0.8-6.2 85D
FLOW
Model RMA-2˝ Scale
Range
Range
SCFH Air
No.
.05-.5
1
.1-1
2
.2-2
3
.5-5
4
1-10
5
2-20
6
5-50
7
10-100
8
15-150
9
20-200
10
CC Air/min.
5-50
151*
10-100
150*
30-240
11
50-500
12
100-1000
13
200-2500
14
LPM Air
.5-5
26
1-10
21
2-25
22
5-50
23
5-70
24
10-100
25
CC Water/min.
5-50
32
10-110
33
20-300
34
Gal.Water/hr
1-11
42
2-24
43
4-34
44
5-50
45
166:Layout 2
7/13/11
9:44 AM
Page 1
Series
VFA
&
VFB
®
Visi-Float Flowmeters
Used to Indicate or Manually Control Air or Water Flow
F
L
M
A
B
DWYER INSTRUMENTS, INC.
MICHIGAN CITY, IND.
C
A
B
D
E
F
I
K
C
K
L
M
FLOW
E
N
D
M
Flowmeter Dimensions
Model VFB
6-1/2 (165.1)
5-1/2 (139.7)
1/8 NPT CONN.
3-1/2 (88.90)
10-32 THD
1/2 (12.70)
1-1/2 (38.10)
1-1/4 (31.75)
2-1/16 (52.39)
OPEN
6-11/16 (169.9)
1-3/8 (34.93)
7/8 (22.23)
1/8 NPT
3/32 (2.381)
Model VFA
4 (101.6)
3 (76.20)
1/8 NPT CONN.
1-5/8 (41.28)
10-32 THD
1/2 (12.70)
1-3/16 (30.16)
1-1/4 (31.75)
2-1/16 (52.39)
OPEN
4-3/32 (104.0)
1 (25.40)
7/8 (22.23)
1/8 NPT
3/32 (2.381)
N
I
FULL OPEN
Flowmeters, Variable Area
Model VFB-SSV
Model VFA-SSV
Durable and attractive construction — The machined acrylic bodies of the
Visi–Float® flowmeters are practically unbreakable. Fabrication is backed by
over 60 years of experience in acrylic instrument machining. The tapered bore
is precision machined to a smooth surface that provides perfect visibility of the
indicating float. The VFA and VFB models are available with either brass or
stainless steel inlet and outlet connections and are tapped for 1/8˝ NPT thread.
VFB models 85 and 86 have either 1/4˝ back or 3/8˝ end connections. All
standard models employ Buna–N “O” rings for leak proof operation and are
available with either back or end connections for horizontal or vertical piping.
Precision metering valves in brass or stainless steel are available for most VFA
and VFB models.
The Visi–Float® flowmeter bodies are cut and precision machined from
solid, clear acrylic plastic blocks. This construction not only produces a
handsome finished product, but permits complete visual inspection. As a result,
the Visi-Float® flowmeters are especially popular for medical and laboratory
equipment applications.
Scales are easy to read — The front scale location and white background
provides excellent visibility. The direct reading scales are hot stamped into the
plastic and will not wear off. Mid–range calibration is established with a master
flowmeter. Accuracy is ±5% of full scale for VFA models, ±3% for VFB. Scales
average 2" long on the VFA models, 4" long on VFB.
Easy installation — All Visi–Float® flowmeters have metal mounting inserts
on rear for panel mounting. They can also be supported directly by system
piping.
166
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
167:Layout 2
7/13/11
9:46 AM
Page 1
Special Multi-Column Visi-Float® Flowmeters
Perfect for OEM applications, Visi-Float® flowmeters can be custom made
with up to 10 columns in a single block of acrylic plastic.
Available with or without valves. Consult factory for more information.
OEM Specials — Special flowmeter designs can be supplied to meet a wide
range of requirements and specific applications. These include: on-off plunger
and push-to-test valves, special gas or fluid calibration, special ranges, scales,
name brand or other identification. Pointer flags can be furnished for instant
visual reference. For specific information, please supply an outline of your
requirements.
SPECIFICATIONS
Service: Compatible gases & liquids.
Wetted Materials:
Body: Acrylic plastic;
O-ring: Buna-N (fluoroelastomer available);
Metal parts: Brass standard, stainless steel optional;
Float: Stainless steel, black glass, aluminum, K monel depending on
range.
Temperature & Pressure Limits:
Without Valve: 100 psig (6.9 bar) @ 150°F (65°C); 150 psig (10 bar)
@ 100°F (38°C);
With Valve: 100 psig (6.9 bar) @ 120°F (48°C).
Accuracy: VFA = 5% of full scale; VFB = 3% of full scale.
Process Connection: 1/8˝ female NPT. VFB ranges 85 and 86 have
1/4˝ NPT back connections or 3/8˝ NPT end connections. These ranges
not available with brass valves.
Scale Length: VFA 2˝ typical length; VFB 4˝ typical length.
Mounting Orientation: Mount in vertical position.
Weight: VFA: 4.0 to 4.8 oz (.11 to .14 kg); VFB: 7.2 to 8.8 oz
(.20 to .25 kg).
FLOW
How To Order
Series—Range No. (“X”)—Valve—Option
Example: VFA-9-BV
Series VFA with 20-200 SCFH Air Range & Brass Valve
VFA Series
VFB Series
Description
Standard VFA
VFA with Stainless Metal Wetted Parts
VFA with Brass Valve
VFA with Stainless Steel Valve
VFA with End Connections
VFA with End Connections and Stainless
Steel Metal Wetted Parts
Model
VFB-X
VFB-X-SS
VFB-X-BV
VFB-X-SSV
VFB-X-EC
VFB-X-EC-SS
OPTIONS & ACCESSORIES
-PF, Red ABS Plastic Pointer Flag
-VIT, Fluoroelastomer O-rings
RKA, Pressure Regulator
Description
Standard VFB
VFB with Stainless Metal Wetted Parts
VFB with Brass Valve
VFB with Stainless Steel Valve
VFB with End Connections
VFB with End Connections and Stainless
Steel Metal Wetted Parts
Flowmeters, Variable Area
Model
VFA-X
VFA-X-SS
VFA-X-BV
VFA-X-SSV
VFA-X-EC
VFA-X-EC-SS
OPTIONS & ACCESSORIES
-PF, Red ABS Plastic Pointer Flag
-VIT, Fluoroelastomer O-rings
RK-VFB, Pressure Regulator
Popular Ranges
Popular Ranges
Model VFA — 2˝ Scale
Range No. Range LPM Air
Range No. Range SCFH Air
.1-1
21
.06-0.5
1
.2-2
22
.15-1
2
.6-5
23
.6-5
3
1-10
24
1-10
4
2-20
25
3-25
5
4-30
26
6-50
6
5-50
27
10-100
7
10-100
8
20-200
9
CC Water per min.
Gal. Water per hour
6-50
41
.6-5
32
10-100
42
2-10
33
20-200
43
3-20
34
44
8-40
Range No.
50
91+
51+
52
53+
54+
55+
90
60
Model VFB — 4˝ Scale
Range SCFH Air Range No.
65
.3-3
66
1-10
67
2-20
68
4-40
69
10-100
10-150
82
20-200
SCFM Air
80+
.3-3
CC/Min. Air
83+
100-1000
84
81
85*
86*
LPM Air
.2-4
1-10
1-20
3-30
4-40
CC/Min. Water
2-30
GPH Water
.5-12
1-20
6-40
6-60
GPM Water
.2-2
.6-5
+
For dual range models in English and Metric add “D” to end of
Range No.
* Ranges 85 and 86 consult factory. Not available with brass
valve.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
167
168:Layout 2
7/13/11
9:47 AM
Page 1
Series
VFC
&
VFCII
®
Visi-Float Flowmeters
Used to Indicate Air or Water Flow
1-3/4
[44.45]
1-1/32
[26.19]
2 NOM
[50.80]
1-1/2 HEX
[38.10]
1-1/2
[38.10]
1-1/8
[28.58]
11
[279.40]
WITH BACK
CONNECTIONS
1-1/8
10-1/2 [28.58]
[266.70]
4-1/2
[114.30]
8-1/2
[215.90]
1-1/2
[38.10]
FLOW
3
[76.20]
1-1/2
[38.10]
VFC with 1˝ FNPT
Back Connections
Flowmeters, Variable Area
VFCII with 1˝ MNPT
End Connections
VFC with 1˝ FNPT
End Connections
The accurate and durable VFC Visi-Float® flowmeter contains a stainless
steel guide rod and large diameter float for excellent stability and visibility in
high flow rates. The large 5˝ scale provides a ±2% full scale accuracy for
precision measurement required in medical or laboratory applications. The
VFC models have PVC 1˝ female NPT connections. VFC II units are equipped
with acetal thermoplastic 1˝ male NPT fittings. VFC II fittings also include
hex wrench flats to prevent stripped threads. All models have metal mounting
inserts on the back for panel mounting. Units may also be supported directly by
system piping.
SPECIFICATIONS
Service: Compatible gases & liquids.
Wetted Materials:
Body: Acrylic plastic;
O-ring: Buna-N (fluoroelastomer available);
Metal parts: Stainless steel;
Float: SS.
Fittings: VFC: PVC; VFCII: Acetal thermoplastic.
Temperature & Pressure Limits: 100 psig (6.9 bar) @ 120°F (48°C).
Accuracy: 2% of full scale.
Process Connection: VFC: 1˝ female NPT back connections. End
connections optional; VFCII: 1˝ male NPT back connections. End
connections optional.
Scale Length: 5˝ typical length.
Mounting Orientation: Mount in vertical position.
Weight: 24 to 25 oz (.68 to .71 kg).
How To Order
Series—Range No.—Option
Example: VFC-123-EC
Series VFC with 10-100 SCFM Air Range and 1˝ female NPT
End Connections
VFC Series
Model
VFC-X
VFCII-X
VFC-X-EC
VFCII-X-EC
Description
VFC with 1˝ FNPT Back Connections
VFCII with 1˝ MNPT Back Connections
VFC with 1˝ FNPT In-Line End Connections
VFCII with 1˝ MNPT In-Line End Connections
Popular Ranges
Range No.
121
122
123
131
132
133
Model VFC — 5˝ Scale
Range SCFM Air Range No.
4-25
141
5-50
142
10-100
143
LPM Air
60-700
151
200-1400
152
300-2800
153
Range GPM Water
.5-5
1-10
2-20
LPM Water
2-20
4-40
10-75
OPTIONS
-VIT, Fluoroelastomer O-Rings
-FDA, 316 SS Float & Guide Rod (only available on VFCII
with fluoroelastomer O-Rings)
168
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
169:Layout 2
7/13/11
9:47 AM
Page 1
Series
UV
™
Ultra-View Polysulfone Flowmeter
Monitor Water Flow Rates from .25 to 40 GPM, Air Rates from 1 to 100 SCFM
5
18
16
Drawing at
right shown
with optional
Polysulfone
Fittings.
Picture at left
shown with
optional
Polysulfone
Fittings.
4
14
12
[307.98]
12
3
15
[381.00]
10
2
8
6
1
4
2
2-1/2
[63.50]
1-7/16-18 UNEF
THREADS
1˝ NPT(M)
THREADS
IN-LINE
THREADS
1˝ NPT(F)
Picture above shown with
optional Polycarbonate Shield
ACCESSORIES
A-801, Panel Mount Kit, Polysulfone Fittings
A-162, In-line Fitting Replacement Kit. Two 1˝ female NPT connection
fittings included in kit.
OPTIONS
UV-XXXX-SHD, Protective Polycarbonate Shield
UV-XX22, PVC 1˝ female NPT Fittings
UV-XXXX-CDS, Certified Data Sheet with Traceability to NIST
SPECIFICATIONS
Service: Compatible liquids and gases.
Wetted Materials: Polysulfone body, fluoroelastomer O-rings and virgin
PTFE float.
Temperature Limits: 35 to 212°F (2 to 100°C); 35 to 130°F (2 to 54°C)
for PVC fitting option.
Pressure Limit: 150 psi (10.34 bar).
Accuracy: ±2% full scale @ 70°F ±2°F (21.1°C) and 14.7 psia (in line
connection rating only).
Repeatability: ±1% full scale @ 70°F ±2°F (21.1°C) and 14.7 psia (in
line connection rating only).
Process Connections: 1˝ female NPT. Optional 90° polysulfone elbow
– 1˝ male NPT.
Scale Length: 6˝ (152.40 mm) – 7˝ (177.80 mm), depending on model.
Fitting Torque: Maximum 22 ft - lb.
Weight: 1 lb (457 g) for 20 GPM range.
CAUTION: Ball valves can have a “water cannon” effect on opening,
creating pressure that exceeds the warrantied ratings and will
damage the flowmeter. Series UV Flowmeters are for indoor use only
or areas without direct sunlight. Polysulfone is adversely affected by
ultraviolet light.
Model
UV-0112
UV-1112
UV-2112
UV-3112
UV-4112
UV-5112
Range (GPM water)
0.25-2.5 (1-9.5 LPM)
0.5-5.0 (2-19 LPM)
1.0-10.0 (4-38 LPM)
2.0-20.0 (8-76 LPM)
3.0-30.0 (12-112 LPM)
4.0-40.0 (20-150 LPM)
Body
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Fitting Material
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Float
Virgin PTFE
Virgin PTFE
Virgin PTFE
Virgin PTFE
Virgin PTFE
Virgin PTFE
Model
UV-A112
UV-B112
UV-C112
UV-D112
Range (SCFM air)
1-13 (30-370 LPM)
2.5-28 (70-780 LPM)
5-50 (70-1400 LPM)
14-100 (400-2800 LPM)
Body
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Fitting Material
Polysulfone
Polysulfone
Polysulfone
Polysulfone
Float
Virgin PTFE
Virgin PTFE
Virgin PTFE
Virgin PTFE
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
169
Flowmeters, Variable Area
APPLICATIONS
• Monitor chill water flow
• Reverse osmosis systems
• Deionized water systems
• Potable water systems
2-15/16
[74.51] 1-1/2
[38.10]
FLOW
Setting a new standard in the industry, the Series UV Polysulfone Flowmeter
is an ultra pure, laboratory grade flowmeter (±2% F.S. accuracy) that measures
flow in GPM and LPM of water, air and other compatible media. The Series UV
is designed to withstand high temperatures up to 212˚F (100˚C) and high pressures
up to 150 psi (10.34 bar). Highly corrosion-resistant, this instrument is an excellent
choice for monitoring many corrosive media. Easy to install and to clean, the
Series UV offers optional panel mount polysulfone fittings and a protective
polycarbonate shield.
17
[431.80]
170:Layout 2
7/13/11
10:25 AM
Page 1
Series
LFM
Polycarbonate Flowmeter
In-Line or Panel Mount Meters
ø1-63/64
[50.40]
ø1-21/32
[42.07]
LFMA
LFMA
LFMB
6-45/64
[170.26]
3-15/16
[100.1]
LFMB
8-55/64
[225.03]
6-5/16
[160.34]
Flowmeters, Variable Area
FLOW
1/2 NPT
1/2 NPT
ACCESSORIES
LFMA
A-560, 20 mm Metric Union Fittings-ABS
A-566, 1/2˝ male NPT Fittings-ABS
SPECIFICATIONS
Service: Water.
Wetted Materials:
Body: Polycarbonate;
Flange nut: ABS;
Float stop: ABS;
O-rings: Fluoroelastomer;
Rod & float: 316 SS;
Connections: Metric union and male NPT fittings-ABS; 90°
male NPT elbow fittings-PVC.
Pressure Limit: 120 psi (8.2 bar) at 68°F (20°C); 90° elbow
fittings 116 psi (8 bar) at 68°F (20°C).
Accuracy: ±5%.
Process Connection: LFMA: 1/2˝ male NPT. Optional 20 mm
metric union; LFMB: 1/2˝ male NPT. Optional 20mm metric
union or 1/2˝ male NPT with 90° elbow.
Weight: LFMA: 2 oz (56.7 g); LFMB: 3 oz (85.0 g).
LFMB
A-561, 20 mm Metric Union Fittings-ABS
A-567, 1/2˝ male NPT Fittings-ABS
A-575, 1/2˝ male NPT with 90° Elbow Fittings-PVC
CAUTION: Series LFM Flowmeters are for indoor use only or
areas without direct sunlight. Polycarbonate is adversely
affected by ultraviolet light.
The New LFM Series Flowmeters are made of injection molded, heat
and chemically resistant polycarbonate bodies and fittings. Series LFM
flow meters have dual scales measuring in both GPM and LPM with 5%
accuracy. A textured background on the body enhances scale readability.
Standard in-line models come with 1/2˝ male NPT process connections
while panel mount installation is available with 90° elbow fittings that
include panel lock nuts. Various other fittings are available.
Model
LFMA-01-A2
LFMA-02-A2
LFMA-03-A2
LFMB-04-A2
LFMB-05-A2
LFMB-06-A2
170
Range (GPM water)
0.1-1 (.5-4 LPM)
0.2-2 (1-7 LPM)
0.5-5 (1.8-18 LPM)
0.1-1 (.5-4 LPM)
0.2-2 (1-7 LPM)
0.5-5 (1.8-18 LPM)
Process Connection
1/2˝ male NPT
1/2˝ male NPT
1/2˝ male NPT
1/2˝ male NPT
1/2˝ male NPT
1/2˝ male NPT
VISIT OUR WEBSITES:
www.dwyer-inst.com
Float
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
171:Layout 2
7/13/11
10:26 AM
Page 1
Series
LFM
Polycarbonate Flowmeter
In-Line or Panel Mount Meters. New Adjustable Set Point Indicator
ø1-63/64
[50.40]
LFMD
LFMC
LFMC
8-9/32
[210.34]
ø2-21/64
[59.13]
LFMD
5-9/32
[134.14]
1/2 NPT
LFMD
A-563, 32 mm Metric Union Fittings-PVC
A-569, 3/4˝ male NPT Fittings-Nylon
A-572, 3/4˝ female NPT Fittings-Nylon
A-577, 3/4˝ male NPT with 90° Elbow Fittings-PVC
Model
LFMC-07-A2
LFMC-08-A2
LFMC-09-A2
LFMD-10-C2
LFMD-11-C2
Range (GPM water)
0.25-2.5 (1-10 LPM)
0.5-5 (1.8-18 LPM)
0.8-8 (3-30 LPM)
0.8-8 (3-30 LPM)
1-10 (4-40 LPM)
CALL TO ORDER:
•
SPECIFICATIONS
Service: Water.
Wetted Materials:
Body: Polycarbonate;
Flange nut: ABS;
Float stop: LFMC-ABS; LFMD-polypropylene;
O-rings: Fluoroelastomer;
Rod & float: 316 SS;
Connections:
90° male NPT elbow fittings-PVC.
20 mm metric union fittings-ABS.
32 mm metric union fittings-PVC.
1/2˝ & 3/4˝ male NPT fittings for LFMC-ABS.
3/4˝ male and female NPT fittings for LFMD-PA66 nylon.
Pressure Limit: 120 psi (8.2 bar) at 68°F (20°C); 90° elbow
fitting 116 psi (8 bar) at 68°F (20°C).
Accuracy: ±5%.
Process Connection: LFMC: 1/2˝ male NPT. Optional 20 mm
metric union, 3/4˝ male NPT, or 1/2˝ male NPT with 90° elbow;
LFMD: 3/4˝ male NPT. Optional 32 mm metric union, 3/4˝ female
NPT, or 3/4˝ male NPT with 90° elbow.
Weight: LFMC: 4 oz (113.4 g); LFMD: 10 oz (283.5 g).
CAUTION: Series LFM Flowmeters are for indoor use only or
areas without direct sunlight. Polycarbonate is adversely
affected by ultraviolet light.
Process Connection
1/2˝ male NPT
1/2˝ male NPT
1/2˝ male NPT
3/4˝ male NPT
3/4˝ male NPT
U.S. Phone 219 879-8000
3/4 NPT
Float
316 SS
316 SS
316 SS
316 SS
316 SS
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
171
Flowmeters, Variable Area
ACCESSORIES
LFMC
A-562, 20 mm Metric Union Fittings-ABS
A-567, 1/2˝ male NPT Fittings-ABS
A-568, 3/4˝ male NPT Fittings-ABS
A-576, 1/2˝ male NPT with 90° Elbow Fittings-PVC
6-45/64
[170.26]
FLOW
The New LFM Series Flowmeters are made of injection molded, heat
and chemically resistant polycarbonate bodies and fittings. Series LFM
flow meters have dual scales measuring in both GPM and LPM with 5%
accuracy. A textured background on the body enhances scale readability. Standard in-line models come with 1/2˝ male NPT connections for
LFMC and 3/4˝ male NPT connections for LFMD. Panel mount installation is available with 90° elbow fittings that includes panel lock nuts.
Various other fittings are available.
9-27/32
[250.03]
172:Layout 2
7/13/11
10:26 AM
Page 1
Series
LFM
Polycarbonate Flowmeter
In-Line or Panel Mount Meters. New Adjustable Set Point Indicator
ø2-27/32
[72.23]
Flowmeters, Variable Area
FLOW
LFME
LFMF
LFME
12-19/64
[312.34]
ø3-15/16
[100.01]
8-55/64
[225.03]
LFMF
15-3/4
[400.05]
2 NPT
1 NPT
SPECIFICATIONS
Service: Water.
Wetted Materials:
Body: Polycarbonate;
Flange nut: ABS;
Float stop: Polypropylene;
O-rings: Fluoroelastomer;
Rod & float: 316 SS;
Connections:
Male & female NPT fittings-PA66 nylon;
1˝ male NPT 90° elbow fittings-PVC;
40 mm metric union fittings-PVC;
63 mm metric union fittings-ABS.
Pressure Limit: 120 psi (8.2 bar) at 68°F (20°C); 90° elbow
fittings 116 psi (8 bar) at 68°F (20°C).
Accuracy: ±5%.
Process Connection: LFME: 1˝ male NPT. Optional 40 mm
metric union, 1˝ female NPT, or 1˝ male NPT with 90° elbow;
LFMF: 2˝ male NPT. Optional 63 mm metric union or 2˝ female
NPT.
Weight: LFME: 15 oz (425.2 g); LFMF: 40 oz (1.1 kg).
The New LFM Series Flowmeters are made of injection molded, heat
and chemically resistant polycarbonate bodies and fittings. Series LFM
flow meters have dual scales measuring in both GPM and LPM with 5%
accuracy. A textured background on the body enhances scale readability.
Standard in-line models come with 1/2˝ male NPT connections for LFME
and 2˝ male NPT connections for LFMF. Panel mount installation is
available with 90° elbow fittings that includes panel lock nuts. Various
other fittings are available.
ACCESSORIES
LFME
A-564, 40 mm Metric Union Fittings-PVC
A-570, 1˝ male NPT Fittings-Nylon
A-573, 1˝ female NPT Fittings-Nylon
A-578, 1˝ male NPT with 90° Elbow Fittings-PVC
LFMF
A-565, 63 mm Metric Union Fittings-ABS
A-571, 2˝ male NPT Fittings-Nylon
A-574, 2˝ female NPT Fittings-Nylon
Model
LFME-12-F2
LFME-13-F2
LFME-14-F2
LFMF-15-I2
LFMF-16-I2
LFMF-17-I2
172
Range (GPM water)
1.2-12 (5-50 LPM)
2-20 (8-80 LPM)
2.5-25 (10-100 LPM)
2.5-25 (10-100 LPM)
5-45 (20-180 LPM)
7-70 (25-250 LPM)
CAUTION: Series LFM Flowmeters are for indoor use only or
areas without direct sunlight. Polycarbonate is adversely
affected by ultraviolet light.
Process Connection
1˝ male NPT
1˝ male NPT
1˝ male NPT
2˝ male NPT
2˝ male NPT
2˝ male NPT
VISIT OUR WEBSITES:
11-27/64
[290.12]
www.dwyer-inst.com
Float
316 SS
316 SS
316 SS
316 SS
316 SS
316 SS
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
173:Layout 2
7/13/11
10:27 AM
Page 1
Direct Reading Glass Flowmeters
Series
DR
65 mm and 150 mm, ±5% FS Accuracy, Interchangeable Flowtubes
Panel Mounting: Drill two 5/8˝ dia. holes at 4.5˝ apart for 65mm models
and 8.812˝ apart for 150 mm models (center-to center).
1
[25.4]
1/8 FNPT
1
[25.4]
1
[25.4]
2X 1/2 HEX
9/16-18 THD
1/8
[3.18]
1/8
[3.30]
5-1/2
[139.7]
9-13/16
[249.24]
3-1/4
[82.55]
4-1/2
[114.3]
65 MM
SCALE
LENGTH
Ø23/32
[Ø18.29]
9-13/16
[249.24]
5/8
[15.88]
1-1/4
[31.75]
OPEN
1-1/4
[31.75]
5/8
[15.88]
1
[25.4]
DR12010*
DR12022
DR12030*
DR12042
Flow Rate (Air) Flow Rate (H2O)
scfh (sccm)
gph (sccm)
–
DR10410* DR12410* 0.24 (130†)
–
DR10422 DR12422 0.65 (300†)
–
DR10430* DR12430* 1.1 (500†)
–
DR10442 DR12442 2.2 (1000†)
scfh (LPM)
–
DR10462 DR12462 5.6 (2.1)
–
DR10470* DR12470* 11 (5)
–
DR10482 DR12482 20 (9.5)
–
DR10490* DR12490* 55 (24)
–
DR104102 DR124102 100 (50)
0.02 (1.5)
DR104120* DR124120* –
0.1 (6.5)
DR104132 DR124132 –
0.13 (8)
DR104140* DR124140* –
0.36 (24)
DR104152 DR124152 –
0.9 (55)
DR104172 DR124172 –
2.2 (140)
DR104180* DR124180* –
4.4 (280)
DR104192 DR124192 –
10 (600)
DR104200* DR124200* –
24 (1500)
DR104212 DR124212 –
Model (150 mm scale)
Without Valve
With Valve
Aluminum SS
Aluminum SS
DR20032 DR22032 DR20432 DR22432
DR20082 DR22082 DR20482 DR22482
DR200132 DR220132 DR204132 DR224132
DR200182
DR200232
DR200282
DR200332
DR200382
DR200432
DR200482
DR200532
DR200582
DR200632
DR200682
DR200732
DR200782
DR220182
DR220232
DR220282
DR220332
DR220382
DR220432
DR220482
DR220532
DR220582
DR220632
DR220682
DR220732
DR220782
DR204182
DR204232
DR204282
DR204332
DR204382
DR204432
DR204482
DR204532
DR204582
DR204632
DR204682
DR204732
DR204782
CALL TO ORDER:
DR224182
DR224232
DR224282
DR224332
DR224382
DR224432
DR224482
DR224532
DR224582
DR224632
DR224682
DR224732
DR224782
Flow Rate (Air)
scfh (sccm)
0.33 (160)
0.54 (270)
2 (840)
scfh (LPM)
3.8 (1.8)
10 (4.8)
16 (7.5)
35 (16)
90 (44)
–
–
–
–
–
–
–
–
U.S. Phone 219 879-8000
•
5/8
[15.88]
1-1/4
1 [31.75]
[25.4] OPEN
8-13/16
[223.84]
1/8
FNPT
5/8
[15.88]1/2
[12.7] 5/8
[15.88]
150 MM
SCALE
LENGTH
ø23/32
[ø18.29]
1-1/4
1 [31.75]
[25.4] OPEN
5/8
[15.88]
1-1/4
[31.75]
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetting Materials:
Flowtube: Borosilicate glass;
Float: 316 SS (black glass as indicated);
Float stops: PTFE;
End fittings: Anodized aluminum or 316 SS;
O-rings: Buna-N on aluminum models and fluoroelastomer on stainless steel
models.
Temperature Limit: 250°F (121°C).
Pressure Limit: 250 psig (17 bar).
Accuracy: ±5% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute).
Repeatability: ±0.25% of scale reading.
Scales: Direct reading 65 mm or 150 mm scales for air or water.
Turn-down Ratio: 10:1.
Connection: 1/8˝ female NPT.
Mounting: Vertical.
Valve: 6-turn needle (standard on models with valve).
APPLICATIONS
Glass flowmeters are suitable for metering gases or liquids for film processing, paper
manufacturing, chemical processing, semiconductor industry, water and air pollution
analysis equipment, metals processing, industrial fuel and energy conservation, cylinder
gas metering, and general laboratory and industrial applications.
Add suffix “M” for metric scale.
* Denotes glass float.
† Metric models use ccm as unit of measure.
Flow Rate (H2O)
gph (sccm)
–
–
–
–
–
–
–
–
0.05 (3.2)
0.075 (4.6)
0.34 (21)
0.75 (46)
2.2 (140)
3.6 (230)
7.5 (480)
21 (1300)
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
173
Flowmeters, Variable Area
DR10062 DR12062
DR10070* DR12070*
DR10082 DR12082
DR10090* DR12090*
DR100102 DR120102
DR100120* DR120120*
DR100132 DR120132
DR100140* DR120140*
DR100152 DR120152
DR100172 DR120172
DR100180* DR120180*
DR100192 DR120192
DR100200* DR120200*
DR100212 DR120212
With Valve
Aluminum SS
1/2
[12.7]
7-9/16
[192.07]
FLOW
Use Series DR Glass Flowmeters to accurately measure flow rates of air or water with
the convenience of a direct reading scale. Permanently fused ceramic scale has integral float
guides for optimum float performance. Reflective plastic background and 1.5 X magnification
lens reduces eye fatigue and allows for more accurate readings. Units include a safety blowout back panel for additional protection. Flowmeters are shipped completely assembled and
include standard panel mounting hardware for quick installation.
DR10010*
DR10022
DR10030*
DR10042
2X 7/8 HEX
LOCKNUT
8-13/16
[223.84]
2X END
CAP
1/2
[12.7]
Model (65 mm scale)
Without Valve
Aluminum SS
5-29/32
150 MM
SCALE
LENGTH
174:Layout 2
7/13/11
10:28 AM
Page 1
Series
VA
Variable Area Glass Flowmeters
65 mm and 150 mm, ±2% FS Accuracy, Interchangeable Flowtubes
Panel Mounting: Drill two 5/8˝ dia. holes at 4.5˝ apart for 65 mm models
and 8.812˝ apart for 150 mm models (center-to center).
1-1/4
[31.75]
1-1/8
[28.70]
10-29/64
[265.68]
150 MM
SCALE
LENGTH
33/64
[13.97]
9/16-18
1/8 NPT
1-1/8
[28.70]
1-1/4
[31.75]
6-5/32
[156.36]
9-15/32
[240.51]
33/64
[13.97]
9/16-18
1/8 NPT
5-5/32
[130.96]
65 MM
SCALE
LENGTH
1/2
[12.70]
1/2
[12.69]
Flowmeters, Variable Area
FLOW
1-27/32
[46.99]
OPEN
Accurately measure flow rates of air, water, and other commonly used gases
with the Series VA Variable Area Glass Flowmeters. Flowmeters are designed
with an easy-to-read universal mm scale and supplied with a correlation chart
containing calibration data for air and water. Correlation data for other gases
and liquids are available. Permanently fused ceramic scale with vertical locator
line reduces parallax and eye fatigue. Thick polycarbonate front shield protects
tube from breakage and also serves as a magnifying lens to enhance reading
resolution.
Glass flowmeters are suitable for metering carrier gases, liquid and gas
measurement in pilot plants, laboratories, process flow and level indicating. Units
are equipped with a standard 6-turn needle valve for flow rate control. High
precision metering valves with non-rising stems (sold separately) are available
for high sensitivity control and resolution – particularly suited for very low flow
rates.
Flowmeters are shipped completely assembled and ready for panel mounting.
Use an optional acrylic tripod base to convert to self-standing bench mounting.
Model 65 mm Scale
Aluminum
Fittings
VA1043
VA1044
VA1045
VA1046
VA1047
VA1048
VA1049
VA10410
VA10411
VA10412
VA10413
VA10414
VA10417
VA10418
VA10419
VA10420
VA10421
VA10422
174
SS
Fittings
VA1243
VA1244
VA1245
VA1246
VA1247
VA1248
VA1249
VA12410
VA12411
VA12412
VA12413
VA12414
VA12417
VA12418
VA12419
VA12420
VA12421
VA12422
Brass
Fittings
VA1343
VA1345
VA1347
VA1349
VA13411
VA13413
VA13417
VA13419
VA13421
-
Float
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Maximum
Maximum
Flow Rate (Air)
scfh (ml/min)
0.104 (49)
0.307 (145)
0.220 (104)
0.633 (299)
0.43 (202)
1.1 (522)
2.09 (986)
4.12 (1946)
2.65 (1249)
5.34 (2520)
4.32 (2040)
8.45 (3990)
13.4 (6318)
25.5 (12058)
27.9 (13153)
52.3 (24680)
49.1 (23169)
89.2 (42094)
Flow Rate (H2O)
gph (ml/min)
0.009 (0.55)
0.038 (2.38)
0.028 (1.8)
0.122 (7.7)
0.041 (2.6)
0.19 (12.0)
0.325 (20.5)
0.881 (55.6)
0.428 (27)
1.125 (71)
0.63 (40)
1.71 (108)
2.33 (147)
5.77 (364)
4.9 (309)
11.81 (745)
8.27 (522)
19.97 (1260)
VISIT OUR WEBSITES:
www.dwyer-inst.com
1-27/32
[46.99]
OPEN
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Flowtube: Borosilicate glass;
Floats: Glass or stainless steel (sapphire, Carboloy and tantalum are
optional);
Float stops: PTFE;
End fittings: Anodized aluminum, 316 SS or brass;
Packings: Fluoroelastomer;
O-rings: Buna-N on aluminum models and brass models, and
fluoroelastomer on stainless steel models.
Temperature Limits: 250°F (121°C).
Pressure Limits: 200 psig (13.8 bar).
Accuracy: ±2% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute).
Repeatability: ±0.25% full scale.
Scales: Universal 65 mm or 150 mm with correlation charts.
Turn-down Ratio: 10:1; 20:1 with combinations of two floats installed in
meter.
Connections: Two 1/8˝ female NPT.
Mounting: Vertical.
Valve: 6-turn needle (standard), optional 16-turn high precision valve.
Valve Orifice: Acetal on aluminum models and brass models, PCTFE
on stainless steel models.
Model 150 mm Scale
Aluminum
Fittings
VA20429
VA20430
VA20433
VA20434
VA20435
VA20436
VA20437
VA20438
VA20439
VA20440
SS
Fittings
VA22429
VA22430
VA22433
VA22434
VA22435
VA22436
VA22437
VA22438
VA22439
VA22440
Brass
Fittings
VA23429
VA23433
VA23435
VA23437
VA23439
-
Float
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Glass
SS
Maximum
Maximum
Flow Rate (Air)
scfh (ml/min)
0.792 (374)
1.725 (814)
4.9 (2313)
9.67 (4562)
8.07 (3807)
16.08 (7590)
18.38 (8678)
35.5 (16737)
49.9 (23564)
93.9 (44336)
Flow Rate (H2O)
gph (ml/min)
0.087 (5.5)
0.323 (20.4)
0.848 (54)
2.067 (130)
1.336 (84)
3.34 (217)
3.32 (210)
8.02 (506)
9.0 (568)
21.7 (1370)
ACCESSORIES
VA81, High precision valve, 316 SS, 0.42 scfh capacity
VA82, High precision valve, 316 SS, 0.85 scfh capacity
VA83, High precision valve, 316 SS, 2.12 scfh capacity
VA84, High precision valve, 316 SS, 4.87 scfh capacity
VA85, High precision valve, 316 SS, 13.14 scfh capacity
VA86, High precision valve, 316 SS, 45.55 scfh capacity
VA7, Acrylic tripod for single meter
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
175:Layout 2
7/20/11
9:37 AM
Page 1
Series
VA
PTFE/Glass Flowmeters
Variable Area, Universal 65 mm and 150 mm Scales, ±2% FS Accuracy
1-1/4
[31.75]
65 MM
SCALE
LENGTH
1-1/8
[28.70]
6-5/32
[156.36]
Panel Mounting: Drill two 5/8˝
dia. holes at 5.2˝ apart for
65mm models and 8.812˝
apart for 150mm models
(center-to center).
5-5/32
[130.96]
9-15/32
[240.51]
1/2
[12.70]
1-27/32 [46.99]
OPEN
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Flowtube: Borosilicate glass;
Float: Glass (sapphire optional);
Float stops and end fittings: PTFE;
O-rings and packings: PTFE.
Temperature Limits: -15 to 150°F
(-26 to 65°C).
Pressure Limits: 100 psi (6.7 bar).
Accuracy: ±2% FS @ 70°F (21.1°C)
and 14.7 psia (1 atm absolute).
Flow Rate (H2O)
gph (ml/min)
0.028 (1.8)
0.047 (2.95)
0.428 (27)
0.630 (39.7)
2.33 (147)
4.9 (309)
8.27 (522)
Series
RSF
10-29/64
[265.68]
Model
Valve
VA25425
VA25429
VA25431
VA25435
VA25437
150 mm scale
No Valve
Float
VA25025 Glass
VA25029 Glass
VA25031 Glass
VA25035 Glass
VA25037 Glass
Repeatability: ±0.25%.
Leak Integrity: 1 x 10-7 sccs of helium.
Scales: Universal 65 mm or 150 mm
with correlation charts.
Turn-down ratio: 10:1, 20:1 with
combinations of two floats installed in
meter.
Connections: Two 1/8˝ female NPT.
Mounting: Vertical.
Valve: 6-turn needle.
Valve Orifice: PTFE.
Flow Rate (Air)
scfh (ml/min)
0.104 (49)
0.792 (374)
1.75 (825)
8.07 (3807)
18.39 (8678)
Flow Rate (H2O)
gph (ml/min)
0.01 (0.61)
0.087 (5.5)
0.262 (16.5)
1.34 (84.3)
3.32 (209)
FLOW
VA1545
VA1547
VA15411
VA15413
VA15417
VA15419
VA15421
Flow Rate (Air)
scfh (ml/min)
0.220 (104)
0.428 (202)
2.646 (1249)
4.322 (2040)
13.39 (6318)
27.9 (13153)
49 (23169)
150 MM
SCALE
LENGTH
1-27/32 [46.99]
OPEN
Measure flow of corrosive or ultra-pure liquids or gases with the Series VA Variable
Area PTFE/Glass Flowmeters. Flowmeters are constructed of chemically inert materials
and housed in a rigid anodized aluminum frame with a polycarbonate safety shield. Units
are designed with an easy-to-read universal mm scale and supplied with a correlation chart
containing calibration data for air and water. Correlation data for other gases and liquids
are available.
ACCESSORY
VA7, Acrylic tripod for single meter
65 mm scale
No Valve
Float
VA1505
Glass
VA1507
Glass
VA15011 Glass
VA15013 Glass
VA15017 Glass
VA15019 Glass
VA15021 Glass
33/64 [13.97]
9/16-18
1/8 NPT
9/16-18
1/8 NPT
1/2
[12.69]
Model
Valve
1-1/8
[28.70]
1-1/4
[31.75]
33/64 [13.97]
Rotatable Scale Flowmeters
3/8-18 NPT
TYP 2 PLACES
3/8-18 NPT
TYP 2 PLACES
10-3/8
[263.53]
10-3/8
[263.53]
11-1/8
[282.58]
3/4
[19.05]
Series RSF Flowmeters are designed with unique rotatable scales of dual, air-water direct
reading graduations. Flow rate is indicated in SCFM and SLPM for air and GPM and LPM
for water. Graduations are marked on a rotating, polycarbonate tubeshield which also serves
to protect the borosilicate glass flowtube. Flowmeters include a reflective plastic background
and 1.5 X magnification lens to reduce eye fatigue and allow for more accurate readings. A
blow-out back panel provides additional protection in the event of breakage. Series RSF
Flowmeters are available in vertical in-line mounting or panel mounting. Units are shipped
completely assembled and include standard mounting hardware for quick installation.
Brass & SS Vertical In-Line Meters
Without Valve
With Valve
Brass
SS
Brass
SS
RSF011
RSF012
RSF013
RSF014
RSF015
RSF111
RSF112
RSF113
RSF114
RSF115
RSF011V
RSF012V
RSF013V
RSF014V
RSF015V
RSF111V
RSF112V
RSF113V
RSF114V
RSF115V
Brass & SS Panel Mount Meters
Without Valve
With Valve
Brass
SS
Brass
SS
RSF021
RSF022
RSF023
RSF024
RSF025
RSF121
RSF122
RSF123
RSF124
RSF125
RSF021V
RSF022V
RSF023V
RSF024V
RSF025V
CALL TO ORDER:
RSF121V
RSF122V
RSF123V
RSF124V
RSF125V
Max. Flow Rate
Air scfm Water GPM
(SLPM) (LPM)
5 (140) 1.2 (4)
10 (280) 2 (8)
15 (425) 3 (11.5)
20 (575) 4 (15)
30 (900) 5 (20)
Max. Flow Rate
Air scfm Water GPM
(SLPM) (LPM)
5 (140) 1.2 (4)
10 (280) 2 (8)
15 (425) 3 (11.5)
20 (575) 4 (15)
30 (900) 5 (20)
U.S. Phone 219 879-8000
•
Flowmeters, Variable Area
Dual, Rotatable Direct Reading Scales for Air and Water
3/4
[19.05]
1-3/4
2 [44.45]
1-7/8
[50.80]
[47.63]
IN-LINE METER
9-15/32
[240.51]
1-7/8
1-1/2
[47.63]
[38.10]
PANEL MOUNT METER
2
[50.80]
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Flowtube: Borosilicate glass.
Float: Brass/SS models: 316 SS; PTFE models: PTFE.
Tube shield: Polycarbonate
Float stops: Brass/SS models: 316 SS; PTFE models: PTFE.
End fittings: Brass/SS models: Brass or 316 SS; PTFE models: PTFE.
O-rings: Brass/SS models: Fluoroelastomer; PTFE models: PTFE.
Temperature Limit: 250°F (121°C). PTFE models: 150°F (65°C).
Pressure Limit: 150 psig (10.34 bar) @ 200°F (93°C). PTFE models: 100 psig
(6.7 bar).
Accuracy: ±7% FS.
Repeatability: ±0.25% FS.
Scale: Direct Reading 127 mm scales for air and water.
Turn-Down Ratio: 10:1.
Connections: Two 3/8˝ female NPT.
Mounting: Vertical or panel mount.
Panel Cutout: Drill two 7/8˝ diameter holes 9.0˝ (229 mm) apart (for panel mount
meters only).
Valve: 6-turn needle (standard on models indicating “with valve”).
Agency Approvals: CE.
Note: For PTFE models contact the factory.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
175
176:Layout 2
7/13/11
11:14 AM
Page 1
Series
VAT
Variable Area Fluoropolymer Flowmeter
In-Line, ±5% Accuracy, Chemically Inert
10
Dimensions
Connection
1/4˝
3/8˝
1/2˝
3/4˝
9
8
7
6
A
5
4
B
3
2
1
0
Constructed entirely of Fluoropolymers, the Series VAT Flowmeters are ideal for
high purity or corrosive liquid applications. Flowmeters feature a 0-10 scale for flow
indication. Each unit is individually leak tested to a leak integrity rating of 1 x 10-7 sccs
Helium or better. The Series VAT are designed for in-line mounting and include a removable
protective shield.
Valve
VAT-311
VAT-312
VAT-313
VAT-314
VAT-315
VAT-316
VAT-317
VAT-318
VAT-319
Model
No Valve
VAT-301
VAT-302
VAT-303
VAT-304
VAT-305
VAT-306
VAT-307
VAT-308
VAT-309
Connections
1/4˝ female NPT
1/4˝ female NPT
1/4˝ female NPT
1/4˝ female NPT
1/4˝ female NPT
3/8˝ female NPT
3/8˝ female NPT
3/8˝ female NPT
3/8˝ female NPT
High Range
Valve
VAT-6110
VAT-6111
VAT-6112
VAT-6113
VAT-6114
No Valve
VAT-6010
VAT-6011
VAT-6012
VAT-6013
VAT-6014
Connections
1/2˝ female NPT
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
B
1-1/4˝ (31.8)
1-1/4˝ (31.8)
2˝ (50.8)
2˝ (50.8)
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials:
Flowtube: PFA;
Float and end fittings: PTFE;
Guide rods: PCTFE.
Temperature Limit: 250°F (121°C).
Pressure Limit: 100 psig (6.9 bar).
Accuracy: ±5% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute).
Process Connections: See chart.
Leak Integrity: 1 x 10-7 sccs of helium.
Scale: 0 to 10 markings.
Mounting: Vertical, in-line.
Low Range
Flowmeters, Variable Area
FLOW
Model
A
5-11/16˝ (144)
5-11/16˝ (144)
10-1/2˝ (267)
10-1/2˝ (267)
Flow Rate
ml/min (gph)
125 (1.98)
250 (3.91)
400 (6.34)
500 (7.92)
1000 (15.85)
2000 (31.69)
2500 (39.62)
3000 (47.54)
5000 (79.23)
Flow Rate
L/min (gpm)
13 (3.43)
20 (5.28)
30 (7.93)
40 (10.57)
45 (11.89)
Series
TVA
All Fluoropolymer Flowmeters
75 mm and 125 mm, 10:1 Turndown, ±5% FS Accuracy
G
Model
TVA11XX
TVA13XX
TVA22XX
TVA24XX
A
4.97 [126]
4.97 [126]
8.72 [221]
8.47 [215]
B
0.56 [14]
0.56 [14]
0.88 [22]
1.00 [25]
C
1.06 [27]
1.25 [32]
1.75 [44]
1.75 [44]
D
3.35 [85]
4.65 [118]
4.57 [116]
5.95 [151]
E
1.25 [32]
1.50 [38]
2.00 [51]
2.25 [57]
F
6.16 [156]
6.16 [156]
10.4 [264]
10.4 [264]
G
1/4
3/8
1/2
3/4
I NPT (F) .750
TYP.
C TYP.
H
A
Panel Mounting: Drill two holes: 3/4˝ dia. at 4.97˝ apart for 1/4˝ NPT
models, 7/8˝ dia. at 4.97˝ apart for 3/8˝ NPT models, 1˝ dia. at 8.72˝ apart for
1/2˝ NPT models, and 1-1/4˝ dia. at 8.47˝ apart for 3/4˝ NPT models (centerto-center).
B
D
Series TVA All Fluoropolymer Flowmeters offer solutions for measuring flow rates of
highly corrosive or ultra-pure liquids. Flowmeters are designed with 0 to 10 scale graduations
denoting a discrete flow rate.
Model
No Valve
TVA1103
TVA1105
TVA1307
TVA1309
Length Connections
75 mm 1/4˝ female NPT
75 mm 1/4˝ female NPT
75 mm 3/8˝ female NPT
75 mm 3/8˝ female NPT
High Range
Valve
TVA22110
TVA24112
TVA24114
No Valve
TVA22010
TVA24012
TVA24014
Length
125 mm
125 mm
125 mm
176
Connections
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
Flow Rate (H2O)
gph (ml/min)
6.34 (400)
15.9 (1000)
39.6 (2500)
79.2 (5000)
Flow Rate (H2O)
gph (l/min)
3.43 (13)
7.93 (30)
11.9 (45)
VISIT OUR WEBSITES:
www.dwyer-inst.com
F
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials:
Flowtube: PFA;
Float and end fittings: PTFE;
Guide rods: PCTFE.
Temperature Limit: 250°F (121°C).
Pressure Limit: 100 psig (6.9 bar).
Accuracy: ±5% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute).
Repeatability: ±0.25%.
Leak Integrity: 1 x 10–7 sccs of helium.
Scales: 0 to 10 markings, 75 mm or 125 mm lengths.
Turn-down Ratio: 10:1.
Mounting: Vertical.
Low Range
Valve
TVA1113
TVA1115
TVA1317
TVA1319
Model
E
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
177:Layout 2
7/13/11
10:39 AM
Page 1
Series
IF
Industrial Direct Reading Flowmeter
Air/Water Direct Reading Scale, 304 SS Protective Shield, ±3% Accuracy
Dimensions
Tube
Female
Size
NPT
1 and 2 1/2˝
3 and 4 1˝
5 and 6 2˝
[B] [D]
Pressure Drop
(in H2O)
–
2
5
6
–
10
10
14
5
6
10
D
8.04 [204]
10.50 [267]
11.55 [293]
SPECIFICATIONS
Service: Liquids or gases.
Wetted Materials:
Flowtube: Borosilicate glass; float,
guide rods, float stops, end;
Fittings: 316 SS;
O-Rings: Fluoroelastomer.
Temperature Limit: 200°F (93°C).
Pressure Limit: 200 psi (13.8 bar);
125 psi for tube size 5 & 6.
Maximum Flow Rate
Water
Air
GPM (LPM) SCFM (LPM)
11 (40)
47.5 (1400)
14 (50)
62 (1800)
20 (75)
90 (2600)
22 (83)
90 (2550)
26 (98)
–
41 (155)
160 (4531)
44 (167)
180 (5098)
60 (227)
245 (6938)
61 (231)
250 (7080)
86 (326)
–
116 (439)
–
Tube
Size
4
4
4
5
4
6
5
6
5
6
6
Accuracy: ±3% of full scale.
Repeatability: ±0.5% of full scale.
Turndown Ratio: 10:1.
Scale: Dual scale GPM and SCFM.
Process Connection: See table.
Mounting: Vertical.
Front Shield: Polycarbonate.
Side Panels: 304 SS.
Pressure Drop
(in H2O)
13
24
39
16
70
5
30
16
40
25
45
Flowmeters, Variable Area
Series
OMA
Model
IF2711
IF2712
IF2713
IF2714
IF2715
IF2716
IF2717
IF2718
IF2719
IF2720
IF2721
C
2.25 [57.2]
3.75 [95.3]
5.25 [133]
FLOW
Model
IF2700
IF2701
IF2702
IF2703
IF2704
IF2705
IF2706
IF2707
IF2708
IF2709
IF2710
Maximum Flow Rate
Water
Air
Tube
GPM (LPM) SCFM (LPM) Size
0.25 (0.95) 1.2 (35)
1
0.36 (1.3)
1.7 (50)
1
0.76 (3.0)
3.3 (90)
1
1 (3.7)
4.2 (120)
2
1.5 (5.6)
6.5 (180)
2
2.2 (8.2)
8.5 (250)
2
3.8 (14)
16 (475)
3
5 (18)
21.5 (650)
3
6 (20)
25.5 (725)
4
7.4 (27.5)
30 (900)
4
9.6 (35)
40 (1200)
4
B
9.54 [242]
13.69 [348]
15.59 [396]
[C]
[A]
Ideal for industrial applications, the Series IF Industrial Direct Reading Flowmeters
are fully enclosed in a brushed stainless steel case. The flowmeters can directly measure
flow rates up to 116 GPM (439 lpm) for water and 250 SCFM (7080 lpm) for air service. The
detachable, clear 3/16˝ thick polycarbonate front shield provides protection at maximum
rated temperature and pressure. Each unit is designed with female NPT end fittings for
easy in-line installation.
A
2 [50.8]
3.5 [89]
5 [127]
Oxygen Flowmeter
Use to Indicate and Manually Control Oxygen Flow
G
B
D
C
A
B
C
D
E
F
G
A
F
OMA-1 & OMA-2
OMA-3 & OMA-4
E
The Compact Series OMA Oxygen Flowmeter is made especially for medical
applications and manually controlling flow from oxygen generators. Flow levels are kept
stable by precision valve and knob adjustment. The low cost flowmeter is made from
durable clear acrylic plastic. The easy-to-read scale is hot stamped into the acrylic so it will
not wear off. The ball float is highly visible against the light blue background. Readings
are repeatable within ±4% full scale accuracy.
Model
OMA-1
OMA-2
OMA-3
OMA-4
DIMENSION-INCHES (MM)
Model OMA-1 & OMA-2
Model OMA-3 & OMA-4
3-3/4 (95.25)
4-37/64 (116.28)
Ø7/8 (Ø22.23)
Ø7/8 (Ø22.23)
2-49/64 (70.25)
3-35/64 (90.09)
Ø21/64 (Ø8.33)
Ø21/64 (Ø8.33)
51/64 (20.24)
51/64 (20.24)
M10x1
M10x1
51/64 (20.24)
51/64 (20.24)
Scale (L/min)
0.1-1.5
0.3-3
0.5-5
1.0-10
SPECIFICATIONS
Service: Oxygen.
Wetted Materials: Acrylic and electroplated brass; Ball float: SS (OMA-1); Agate
(OMA-2,-3,-4); O-ring: NBR.
Pressure Limits: 29 psi (2.0 bar).
Temperature Limits: 32 to 140°F (0 to 60°C).
Accuracy: ±4% of full scale.
Connection: 1/4˝ I.D. tubing.
Mounting: Vertical.
ACCESSORY
A-222, .240˝ I.D. x .375˝ O.D. tubing
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
177
178:Layout 2
7/13/11
10:39 AM
Page 1
Series
RMV
®
Rate-Master Dial-Type Flowmeters
Brass Body; Three Ranges to 20 GPM Water
Model
RMV-1-3
RMV-2-3
RMV-3-3
RMV-1-2
RMV-2-2
RMV-3-2
RMV-1-1
RMV-2-1
RMV-3-1
Range, GPM Water
0-5
0-10
0-20
0-5
0-10
0-20
0-5
0-10
0-20
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Brass, copper, 302 SS, sintered barium ferrite.
Temperature Limits: 20 to 200°F (-6.7 to 93°C).
Pressure Limit: 1000 psig (68.9 bar).
Pressure Drop: 0-5 GPM: 3.2 psid; 0-10 GPM: 5.3 psid; 0-20 GPM: 10.4 psid.
Accuracy: ±2% of full scale.
Size: Diameter dial face 4˝ (101.6 mm).
Process Connections: See chart.
Maximum Flow: 1.5 x full scale reading.
Weight: 9 Ib (4.08 kg).
Connection Size
1˝ female NPT
1˝ female NPT
1˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
1/2˝ female NPT
1/2˝ female NPT
1/2˝ female NPT
Series
RMV II
Flowmeters, In-Line
FLOW
Series RMV Rate-Master® Flowmeters measure higher water flow rates with ±2% of full
scale accuracy at affordable prices. Rugged forged brass housing is standard on all models for
great compatibility and the strength to withstand system pressures to 1000 psig (68.9 bar).
Unlike glass tube rotameters, these units won’t shatter and they work fine with even dark
and/or opaque liquids. Stocked models are fitted with 1˝ female NPT inlet and outlet; 3/4˝ and
1/2˝ sizes are also available. Install in line, supported by piping or flush panel mount with
complete hardware package included.
APPLICATIONS
Monitor coolant flow through ingot heaters, high-amp switchgear, resistance welders,
heat exchangers, compressors, scrubbers; monitor water consumption to different
processes and operations for more efficient operation; calculate required fill or drain
times for tanks, water towers.
®
Rate-Master Dial-Type Flowmeter
For Panel Mounting, Three Ranges to 10 GPM Water
(3) 7/32 DIA [5.6]
HOLES ON 5-3/8 DIA
[136.5] BOLT CIRCLE
120°
TYP.
1
[25.40]
11/32
[8.85]
2
[50.80]
4-5/8 DIA.
1-19/64 [117.98]
[33.02]
5-7/8 DIA.
[149.2]
1-1/4
[31.75]
3/4˝ NPT TYP.
BOTH ENDS
4-7/16
[112.78]
*FITS IN ANSI STANDARD 4.940 [125.5] PANEL CUTOUT
Series RMV II Rate-Master® Flowmeters employ a target-type design combined with a
damage resistant magnetic linkage to drive a pointer over an easy-to-read litho scale. This
unique construction fully isolates flowing media from gage front for leakproof operation at
pressures to 3000 psig (206.7 bar) with ±5% of full scale accuracy. Solid machined brass
meter body is ideally suited for water flows. Body design fits standard 4 1/2˝ mounting hole
layouts per ANSI B40.1. Inlet and outlet threads are standard 3/4˝ female NPT.
Model
RMVII-1
RMVII-3
RMVII-6
RMVII-10
178
Range
GPM Water
0-3
0-5
0-10
–
Range
SCFM
–
–
–
0-10
Range
LPM Air
–
–
–
0-280
Model
RMVII-12
RMVII-14
RMVII-20
RMVII-21
RMVII-22
Range
GPM Oil
–
–
0-2.2
0-4.0
0-18.5
VISIT OUR WEBSITES:
Range Range
SCFM LPM Air
0-30 0-850
0-50 0-1400
–
–
–
–
–
–
SPECIFICATIONS
Service: Compatible gases & liquids & oils.
Wetted Materials: Brass, 302 SS, sintered barium ferrite, polyacetyl.
Temperature Limit: 200°F (93°C).
Pressure Limit: 3000 psig (206 bar).
Pressure Drop: 0-5 GPM: 3.2 psid; 0-10 GPM: 5.3 psid; 0-20 GPM: 10.4 psid.
Accuracy: ±5% of full scale.
Size: Diameter dial face 4.5˝ (114.3 mm).
Process Connections: 3/4˝ female NPT.
Weight: 2 lb, 14 oz (1.3 kg).
Range
LPM Oil
–
–
0-8
0-15
0-32
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
179:Layout 2
7/13/11
10:40 AM
Page 1
Series
HFPC
&
HFPS
Plastic Flowmeters
± 5% FS Accuracy, Mount in any Position
ø2-7/16
[61.91]
“L”
Meter Size
1/2 male
1/2 female
3/4 male
3/4 female
1 male
1 female
CAUTION: Series HFPC & HFPS Flowmeters are for indoor use only or areas
without direct sunlight. Polycarbonate & polysulfone are adversely affected by
ultraviolet light.
CALL TO ORDER:
Flowmeters, In-Line
TYPICAL PRESSURE DIFFERENTIAL
Series HF Plastic Flow Meters
Polycarbonate Body, Polysulfone Connections
Polysulfone Body, Polysulfone Connections
1/2˝ female NPT
3/4˝ female NPT
1˝ female NPT
1/2˝ male NPT Brass Connections Only
3/4˝ male NPT Brass Connections Only
1˝ male NPT Brass Connections Only
1/2˝ female BSPP
3/4˝ female BSPP
1˝ female BSPP
.5-5 GPM (1-19 LPM)
1-10 GPM (3.8-38 LPM)
2-15 GPM (7.5-55 LPM)
3-30 GPM (11-113 LPM)
Brass Connections
U.S. Phone 219 879-8000
•
PRESSURE DIFFERENTIAL: PSID
Series
HF
PC
Wetted Parts
PS
Connection
-1
-2
-3
-4
-5
-6
-7
-8
-9
Range
-1
-2
-3
-4
Option
-BC
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: HFPC: Polycarbonate body, Buna-N seals, stainless steel
spring, Polysulfone connections; HFPS: Polysulfone body, Buna-N seals, stainless
steel spring, polysulfone connections.
Pressure Limit: 325 psig (22.4 bar).
Temperature Limit: HFPC: 200˚F (93˚C); HFPS: 250˚F (121˚C).
Accuracy: ±5% FS.
Repeatability: ±1% FS.
Pressure Loss: See chart.
Weight: Standard models 1 lb (453.6 g). Models with optional brass connections
2 lb (907 g).
U.K. Phone (+44) (0)1494-461707
FLOW RATE: GPM
•
Australia Phone (+61) (0) 2 4272 2055
FLOW
The New HFPC & HFPS Series Flowmeters are made of injection molded, polycarbonate
and polysulfone bodies. Series HFPC and HFPS flowmeters have dual scales measuring in
both GPM and LPM with ±5% full scale accuracy. Models are available with 1/2˝, 3/4˝ or 1˝
male or female NPT connections. Female 1/2˝, 3/4˝ and 1˝ BSPP connections are also
available. Rugged construction allows these meters to handle maximum pressures of 325
psig and 200˚F. Units can be mounted in any position, even applications with downward
flow.
DIM “L”
7-11/16 [195.26]
7-5/32 [181.76]
8-1/32 [204.00]
7-9/16 [192.09]
8-3/32 [205.58]
7-9/16 [192.09]
179
180:Layout 2
7/13/11
10:44 AM
Page 1
Series
HF
In-Line Flow Monitors
For Air, Water or Caustic Fluids, ±2.5% Accuracy, Unrestricted Mounting
[“A”]
Connection
Size
1/4˝ to 1/2˝ NPT
3/4˝ to 1˝ NPT
1-1/2˝ NPT
2˝ NPT
[“C”]
“A”
Reference
1-7/8˝ (48 mm)
2-3/8˝ (60 mm)
3-1/2˝ (89 mm)
3-1/2˝ (89 mm)
“B”
Wrench Flats
1-1/4˝ (32 mm)
1-3/4˝ (45 mm)
2-5/8˝ (67 mm)
2-5/8˝ (67 mm)
“C”
Reference
6-9/16˝ (167 mm)
7-1/8˝ (181 mm)
10-1/8˝ (257 mm)
12-5/8˝ (321 mm)
Flowmeters, In-Line
FLOW
[“B”]
Low cost, Series HF In-Line Flow Monitors have a design based on a
floating sharp-edged orifice disk and variable area flow measurement to yield
accuracy of ±2.5% over center one-third of scale. This unique design allows
accurate performance with fluid viscosities up to 500 SSU. All internal wetted
parts are contained inside a sealed metal tubular casing assuring a virtually
maintenance-free unit. Flowing media forces linear motion of a spring loaded,
sharp edge orifice disk and ring shaped transfer magnet which both ride on a
tapered center shaft. The transfer magnet drives a clearly visible magnet
follower located outside the flow tube, protected under the clear polycarbonate
tube. A ring on the magnet follower indicates flow rate on the direct reading
scale. Rubber bumpers are provided for external impact resistance.
Designed for single-direction flow, Series HF Monitors are recommended for use
with system filtration of at least 74 microns or a 200 mesh screen. Some
applications may also require magnetic filtration. These flowmeters do not require
inlet or outlet straight plumbing and can be mounted horizontally, vertically, or
inverted.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: HFA: Aluminum casing, Buna-N seals, PTFE coated
Alnico magnet, stainless steel disk; HFB: Brass casing, Buna-N seals,
PTFE coated Alnico magnet, stainless steel disk; HFS: 303 stainless
steel casing, FKM seals with PTFE backup, PTFE coated Alnico
magnet, stainless steel disk; HFH: Brass casing, FKM seals with PTFE
backup, PTFE coated Alnico magnet, stainless steel disk.
Maximum Viscosity: 500 SSU.
Temperature Limits: HFA, HFL, HFB and HFS models: 240°F (116° C);
HFH models: 400°F (204°C).
Pressure Limits: HFA models: 600 psig (41 bar); HFL, HFB and HFH
models: 3500 psig (240 bar); HFS: 1000 psig (70 bar) for air and gas,
6000 psig (413 bar) for liquids.
Accuracy: ±4% FS over entire range; ±2.5% over center third of the
measuring range.
Repeatability: ±1% of full scale.
Shipping Weight: 1/4˝ to 1/2˝ female NPT models; 2 lb (0.9 kg); 3/4 to
1˝ female NPT models: 3.5 lb (1.59 kg); 1-1/2˝ female NPT models: 11 lb
(5 kg); 2˝ female NPT models: 13.5 lb (6.12 kg).
APPLICATIONS
HF Flow Monitors can be used to set flow rates, fluid motor and cylinder
speeds. Check pump high pressure performance, pressure relief valve
settings, fluid handling systems in agricultural, construction or industrial
machinery, power tools and equipment. Monitor petrochemical operations
with brass or stainless steel models. Industrial pneumatic systems air flow
can be monitored with the HFA models which are calibrated at 100 psig inlet
pressure.
180
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
181:Layout 2
7/13/11
10:45 AM
Page 1
Aluminum body for oil based fluids:
Brass body for water based fluids (non-steam):
Model
HFB-2-05
HFB-3-15
HFB-3-20
HFB-4-35
HFB-5-50
HFB-5-100
HFB-6-75
HFB-6-150
Connection
Size
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
1˝ female NPT
1-1/2˝ female NPT
1-1/2˝ female NPT
2˝ female NPT
2˝ female NPT
Connection
Model
Size
HFL-2-05 1/2˝ female NPT
HFL-4-25 1˝ female NPT
Range, Water
GPM (LPM)
0.5-5.0 (1-19)
2-15 (7.5-55)
2-20 (7.5-75)
5-35 (19-130)
5-50 (19-189)
10-100 (38-379)
8-75 (31-284)
20-150 (76-568)
Range, GPM
(LPM) Oil
0.5-5.0 (1-19)
2-25 (7.5-95)
304 SS body for high-pressure fluids:
Connection
Model
Size
HFS-2-02 1/2˝ female NPT
HFS-2-10 1/2˝ female NPT
Range, Water
GPM (LPM)
0.2-2.0 (0.75-7.5)
0.5-10 (1.9-38)
Aluminum, Brass, and Stainless Steel for air and other non-corrosive gases:
U.S. Phone 219 879-8000
Stainless Steel
HFS-1-001
HFS-1-002
HFS-1-003
HFS-1-004
HFS-8-001
HFS-8-002
HFS-8-003
HFS-8-004
HFS-2-001
HFS-2-002
HFS-2-003
HFS-2-004
HFS-3-003
HFS-3-004
HFS-3-005
HFS-3-006
HFS-4-003
HFS-4-004
HFS-4-005
HFS-4-006
HFS-9-007
HFS-9-008
HFS-5-007
HFS-5-008
•
Connection (NPT female, dry seal)
1/4˝
1/4˝
1/4˝
1/4˝
3/8˝
3/8˝
3/8˝
3/8˝
1/2˝
1/2˝
1/2˝
1/2˝
3/4˝
3/4˝
3/4˝
3/4˝
1˝
1˝
1˝
1˝
1-1/4˝
1-1/4˝
1-1/2˝
1-1/2˝
U.K. Phone (+44) (0)1494-461707
•
Range scfm (lps)
1.5-12 (0.5-5.5)
4-23 (2-10)
5-50 (2.5-25)
10-100 (5-45)
1.5-12 (.5-5.5)
4-23 (2-10)
5-50 (2.5-25)
10-100 (5-45)
1.5-12 (.5-5.5)
4-23 (2-10)
5-50 (2.5-25)
10-100 (5-45)
5-50 (3-23)
10-100 (4-48)
15-150 (8-56)
30-330 (20-150)
5-50 (3-23)
10-100 (4-48)
15-150 (8-56)
30-330 (20-150)
30-470 (15-220)
150-900 (75-425)
30-470 (15-220)
150-900 (75-425)
Australia Phone (+61) (0) 2 4272 2055
Flowmeters, In-Line
CALL TO ORDER:
Brass
HFB-1-001
HFB-1-002
HFB-1-003
HFB-1-004
HFB-8-001
HFB-8-002
HFB-8-003
HFB-8-004
HFB-2-001
HFB-2-002
HFB-2-003
HFB-2-004
HFB-3-003
HFB-3-004
HFB-3-005
HFB-3-006
HFB-4-003
HFB-4-004
HFB-4-005
HFB-4-006
HFB-9-007
HFB-9-008
HFB-5-007
HFB-5-008
FLOW
Aluminum
HFA-1-001
HFA-1-002
HFA-1-003
HFA-1-004
HFA-8-001
HFA-8-002
HFA-8-003
HFA-8-004
HFA-2-001
HFA-2-002
HFA-2-003
HFA-2-004
HFA-3-003
HFA-3-004
HFA-3-005
HFA-3-006
HFA-4-003
HFA-4-004
HFA-4-005
HFA-4-006
HFA-9-007
HFA-9-008
HFA-5-007
HFA-5-008
181
182:Layout 2
7/13/11
10:46 AM
Page 1
Series
SSM
All Metal Flowmeter
Available in Stainless Steel for Industrial Environments
15.640
[397]
10.780
[273]
4.026
[102]
2.680
[68]
4.503
[114]
3/4˝ NPT
Ø 1.350 [34.3]
Ø 2.754
[70]
5.695
[145]
Flowmeters, In-Line
FLOW
3/4˝ Models
Series SSM 316 All Metal Flowmeters are ideal for dirty or opaque fluids,
high temperature and high pressure service and harsh environments. The direct
reading scale provides ±2% accuracy on approximate 25 to 1 ranges, which are
wider than typical variable area ball float flow meters. The internal magnet
carries the external flow indicator in a non-wetted enclosure. Flowmeters can
quickly be disassembled without removing the body from the pipeline for easy
cleaning. Pipe adaptors may be used to adapt to alternate size liner without
altering accuracy.
316 SS
Body
SSM-00
SSM-01
SSM-02
SSM-03
SSM-04
SSM-05
SSM-06
SSM-07
SSM-08
SSM-09
SSM-10
SSM-11
SSM-12
SSM-13
182
Range
0.2-5.4 GPM Water (0.75-21 LPM)
0.2-10 GPM Water (1-35 LPM)
0.5-23 GPM Water (0.5-90 LPM)
0.5-35 GPM Water (2-130 LPM)
1-50 GPM Water (8-200 LPM)
2-70 GPM Water (2-265 LPM)
4-120 GPM Water (15-450 LPM)
2-50 SCFM Air (4-85 M3/HR)
6-125 SCFM Air (10-210 M3/HR)
4-260 SCFM Air (10-440 M3/HR)
2-310 SCFM Air (10-530 M3/HR)
10-515 SCFM Air (20-880 M3/HR)
35-750 SCFM Air (40-1300 M3/HR)
20-1000 SCFM Air (40-1700 M3/HR)
VISIT OUR WEBSITES:
Connection
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
www.dwyer-inst.com
1-1/2˝ NPT
124072
2.810
[71.4]
3.710
[94]
Ø 4.010
[101.8]
Ø 2.480
[63]
1-1/2˝ Models
SPECIFICATIONS
Service: Compatible liquids and gases.
Wetted Material: T316 SS, Alnico magnet, FKM O-ring.
Temperature Limits: 300ºF (149ºC).
Pressure Limits: 3/4˝ models: 1000 psig (68.9 bar) @ 250ºF (121ºC),
1-1/2˝ models: 800 psig (55 bar) @ 250ºF (121ºC).
Accuracy: ±2% full scale.
Repeatability: ±0.5% of indicated flow rate.
Process Connections: 3/4˝ or 1-1/2˝ female NPT.
Scale Length: 3/4˝ models: 3.2˝ (8 cm); 1-1/2˝ models: 5.2˝ (13 cm).
Weight: 3/4˝ models: 5 lb (2.3 kg); 1-1/2˝ models: 13 lb (5.9 kg).
Max. Pressure
Loss (in w.c.)
17.2
22.0
75.0
18.5
26.0
80.0
130.0
4.5
11.8
93.0
12.0
40.0
70.0
90.0
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
183:Layout 2
7/13/11
10:46 AM
Page 1
Series
STFLO
Stainless Steel Flowmeters
Ideal for Steam Applications
15-21/32
[397.28]
10-21/32
[270.78]
OUT
2-13/16
[71.37]
OUT
4-1/2
[114.38]
3/4 NPT
1-1/2 NPT
Ø2-15/32
[62.99]
Ø4
[101.85]
IN 3-23/32
[94.23]
5-11/16
[144.65]
Ø1-11/32
IN
2-11/16
[34.29]
[68.07]
4-1/32
2-3/4
[102.25]
[69.95]
3/4 NPT CONNECTION
1-1/2 NPT CONNECTION
3
[76.20]
2-1/8
[53.59]
3
[76.20]
3-1/2
[88.91]
6-13/16
[172.97]
Ø3-7/8
[Ø98.55]
Ø2-3/4
[Ø69.85]
5
[127.00]
3-11/16
[93.73]
3-9/16
[90.43]
3-7/8
[98.55]
4-31/32
[125.98]
3/4 FLANGE CONNECTION
Model
STFLO-00
STFLO-01
STFLO-02
STFLO-03
STFLO-04
STFLO-05
STFLO-06
STFLO-07
STFLO-08
STFLO-09
STFLO-10
STFLO-11
STFLO-12
STFLO-13
STFLO-14
Range
2.3-50 lb/Hr. Steam
5-100 lb/Hr. Steam
5-150 lb/Hr. Steam
9.5-240 lb/Hr. Steam
14-335 lb/Hr. Steam
18.5-405 lb/Hr. Steam
28.5-770 lb/Hr. Steam
28.5-1230 lb/Hr. Steam
7-100 lb/Hr. Steam
7-150 lb/Hr. Steam
14.5-335 lb/Hr. Steam
24-800 lb/Hr. Steam
28.5-1200 lb/Hr. Steam
14.5-1480 lb/Hr. Steam
35-1825 lb/Hr. Steam
Connection
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
5
[127.00]
1-1/2 FLANGE CONNECTION
SPECIFICATIONS
Service: Compatible with liquids and gases.
Wetted Material: T316 SS, Alnico magnet, geothermal EPR O-ring.
Temperature Limits: See chart.
Pressure Limits: See chart.
Accuracy: ±2% full scale.
Repeatability: ±0.5% of indicated flow rate.
Process Connections: 3/4˝ or 1-1/2˝ female NPT, optional flange connections.
Scale Length: 3/4˝ models: 3.2˝ (8 cm); 1-1/2˝ models: 5.2˝ (13 cm).
Weight: 3/4˝ NPT models: 5.75 lb (2.6 kg); 1-1/2˝ NPT models: 14 lb (6.4 kg). 3/4˝
Flange: 9.75 lb (4.4 kg); 1-1/2˝ Flange: 22 lb (10 kg).
MAXIMUM NON-SHOCK WORKING PRESSURE, psig (bar)
Meter Size 0°F
70°F 300°F 350°F 400°F 450°F 500°F 600°F
& Material (-18°C) (21°C) (148°C) (176°C) (204°C) (232°C) (260°C) (315°C)
(3/4˝ NPT) 1000 1000 1000
990
970
950
930
900
(68.9) (68.9) (68.9) (68.2) (66.8) (65.5) (64.1) (62)
(1-1/2˝ NPT) 800
800
800
790
780
770
760
750
(55)
(55)
(55)
(54.4) (53.7) (53)
(52.4) (51.7)
Note: For ranges calibrated for water or air contact the factory.
OPTIONS
If you wish to change 3/4˝ NPT to 3/4˝ Flanged Connection, add F1 to the end of the
model number. If you wish to change 1-1/2˝ NPT to 1-1/2˝ Flanged Connection, add
F2 to the end of the model number.
F1, 3/4˝ 150 lb ANSI flange connection
F2, 1-1/2˝ 150 lb ANSI flange connection
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
183
Flowmeters, In-Line
The STFLO Series Stainless Steel Flowmeters are ideal for high temperature and
high pressure applications such as steam. The direct reading scale provides ±2% accuracy.
These flowmeters can be quickly disassembled without removing the body from the pipeline
for easy cleaning.
FLOW
4-1/2
[114.30]
184:Layout 2
7/13/11
10:48 AM
Page 1
Series
TVF
Total View Industrial Flowmeter
View Flow Rate from 360° Water or Air Ranges
REMOVAL
G CLEARANCE
A
TVFS
Flowmeters, In-Line
FLOW
OUT
A
9.36
15.22
B
2.81
4.53
C
2.68
3.71
D
4.00
5.70
E
1.35
2.48
F
2.72
3.95
G
Female NPT
3.00 3/4˝
5.00 1-1/2˝
B
CONNECTIONS
Material
SS
SS
IN
C
E
F
D
The Series TVF Total View Industrial Flowmeters are economically priced, tough,
simple and accurate meters for water, oils, coolants, compressed gases and other industrial
applications. The flowmeters have a full-scale accuracy of ±2% and can be disassembled
quickly without the meter being removed from the pipeline for easy cleaning. The TVFS is
constructed of T-316 stainless steel and features a polysulphone sight tube. The Series Total
View Industrial Flowmeters are available with standard 3/4˝ and 1-1/2˝ female NPT
connections. The easy to read flowmeters provide 360° rotation of scale on plastic sight
tube models.
Series
Range
Code
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: Body: Stainless steel; O-rings: Buna-N; Sight tube: Polysulfone.
Temperature Limits: see “Operating Limits” table.
Pressure Limits: see “Operating Limits” table.
Accuracy: ±2% of full scale.
Repeatability: ±1/4% of indicated flow rate.
Process Connections: 3/4˝ and 1-1/2˝ female NPT.
Scale Length: 3.2˝ (8 cm) for 3/4˝ NPT connection, 5.2˝ (13 cm) for
1-1/2˝ NPT connection.
Weight: 4 lb (1.8 kg) for 3/4˝, and 12 lb (5.5 kg) for 1-1/2˝.
T-316 Stainless Steel
See Range/ Connection Chart
(add Range code to Series
designator for model number)
TVFS
-XX
Operating Limits
Maximum Non-Shock Working Pressure psig @ °F (bar @ °C)
Connection 200°F (93°C) 250°F (121°C)
300°F (148°C)
3/4˝
300 (20.6)
250 (17.2)
115 (7.9)
1-1/2˝
180 (12.4)
145 (10.0)
70 (4.8)
*Contact factory for optional metric scales (liters/minute).
Available Ranges
Range
Code
-00
-01
-02
-03
-04
-05
-06
-07
-08
-09
-10
-11
-12
-13
-14
-15
-16
-17
-18
184
Range
0.025-0.545 GPM Water
0.04-0.80 GPM Water
0.06-1.20 GPM Water
0.08-1.64 GPM Water
0.10-2.60 GPM Water
0.15-3.80 GPM Water
0.20-5.40 GPM Water
0.20-7.00 GPM Water
0.20-10.0 GPM Water
0.60-14.00 GPM Water
0.50-23.00 GPM Water
0.50-11.0 GPM Water
0.70-15.0 GPM Water
1.00-21.0 GPM Water
0.50-35.0 GPM Water
1.00-50.0 GPM Water
2.00-70.0 GPM Water
3.00-90.0 GPM Water
4.00-120.0 GPM Water
Connection
(female NPT)
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
Range
Code
-19
-20
-21
-22
-23
-24
-25
-26
-27
-28
-29
-30
-31
-32
VISIT OUR WEBSITES:
Range
0.16-3.20 SCFM Air
0.50-5.00 SCFM Air
0.30-7.40 SCFM Air
0.50-10.2 SCFM Air
0.60-14.0 SCFM Air
1.00-20.0 SCFM Air
1.00-26.0 SCFM Air
1.00-35.0 SCFM Air
2.00-50.0 SCFM Air
3.00-70.0 SCFM Air
4.00-85.0 SCFM Air
6.00-125.0 SCFM Air
6.0-160.0 SCFM Air
4.00-260.0 SCFM Air
Connection
(female NPT)
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
3/4˝ NPT
www.dwyer-inst.com
•
Range
Code
-33
-34
-35
-36
-37
-38
-39
-40
-41
-42
-43
-44
-45
Range
1.50-25.0 SCFM Air
1.00-31.0 SCFM Air
2.00-40.0 SCFM Air
3.0-70.0 SCFM Air
4.0-100.0 SCFM Air
5.0-140.0 SCFM Air
5.0-175.0 SCFM Air
6.00-250.0 SCFM Air
2.00-310.0 SCFM Air
7.50-390.0 SCFM Air
10.0-510.0 SCFM Air
35.0-750.0 SCFM Air
20.0-1000.0 SCFM Air
www.dwyer-inst.co.uk
•
Connection
(female NPT)
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
1-1/2˝ NPT
www.dwyer-inst.com.au
185:Layout 2
7/13/11
10:49 AM
Page 1
Series
CIF
Combustion Flowmeter
For Low Pressure Gas Flow
CIFN SERIES
CIFS SERIES
C
D
B
E
A
FNPT A
3/4˝ 18-5/32
[461.17]
26-3/8
2˝
[699.93]
31-13/64
3˝
[792.56]
33-37/64
4˝
[852.89]
CIFS
CIFN
CIFS
Ni Plated Steel Body
All Stainless Steel
-XX
See Range/ Connection Chart
Range
(add Range code to Series
Code
designator for model number)
* For optional 3˝ and 4˝ connections ranging up to 30,000 SCFH, flange
connections, and metric scales (liters/minute), contact the factory.
Series
Available Ranges
Range Code Range
-00
0.8-20.0 SCFH Air
-01
1.0-30.0 SCFH Air
-02
2.0-50.0 SCFH Air
-03
3.0-75.0 SCFH Air
-04
4.0-100 SCFH Air
-05
6.0-150 SCFH Air
-06
10-250 SCFH Air
-07
10-350 SCFH Air
-08
20-500 SCFH Air
-09
30-750 SCFH Air
-10
40-1000 SCFH Air
CALL TO ORDER:
Connection (NPT)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
U.S. Phone 219 879-8000
•
Range Code
-11
-12
-13
-14
-15
-16
-17
-18
-19
-20
B
7-57/64
[200.42]
12-41/64
[321.07]
14-41/64
[371.87]
16-9/64
[409.97]
C
2-13/64
[55.96]
3-13/32
[86.52]
4-57/64
[124.22]
6
[152.4]
D
2-1/2
[63.5]
3-1/2
[88.9]
4-3/4
[120.65]
6
[152.4]
E
1-29/64
[36.91]
2-3/4
[69.85]
4
[101.6]
5
[127]
SPECIFICATIONS
Service: Compatible gases.
Wetted Materials: CIFN: Nickel plated steel body, 18-8 stainless steel,
Buna-N O-rings, polysulfone sight tube; CIFS: 18-8 stainless steel,
Buna-N O-rings, 18-8 stainless steel sight tube.
Temperature Limits: 600°F (315°C).
Pressure Limits: 150 psig (10 bar).
Maximum Pressure Drop: 2˝ w.c. (500 Pa).
Accuracy: ±2% of reading for dry air at 14.7 psig (1 bar), 70°F (21°C).
Repeatability: ±1/4% of indicated flow rate.
Process Connections: 3/4˝ and 2˝ female NPT, optional 3˝ and 4˝
female NPT.
Weight: 8 lb (6.4 kg) for 3/4˝ and 25 lb (11.4 kg) for 2˝.
Range
20-500 SCFH Air
30-750 SCFH Air
40-1000 SCFH Air
50-1200 SCFH Air
60-1500 SCFH Air
80-2000 SCFH Air
100-2500 SCFH Air
120-3000 SCFH Air
160-4000 SCFH Air
200-5000 SCFH Air
U.K. Phone (+44) (0)1494-461707
•
Connection (NPT)
2˝
2˝
2˝
2˝
2˝
2˝
2˝
2˝
2˝
2˝
Australia Phone (+61) (0) 2 4272 2055
185
Flowmeters, In-Line
The Series CIF Combustion Flowmeters are tough, simple and accurate
meters for low pressure, low-density gas measurement. They have a verifiable
accuracy of ±2% for combustion gases, annealing atmospheres, vacuum flows,
digesters and gas mixing. They can be disassembled quickly without the meter
being removed from the pipeline for easy cleaning. Series CIF Combustion
Flowmeters are extremely robust constructed of nickel plated steel or optional
stainless steel with maximum pressure ratings of 150 psig (10.34 bar) and
temperature ratings of 600°F (315°C).
A1
18-29/32
[480.22]
26-31/32
[685]
32-13/64
[817.96]
34-37/64
[878.29]
FLOW
CIFN
A1
186:Layout 2
7/13/11
10:49 AM
Page 1
PVC and CPVC Flowmeters
Series
PVF
&
CPF
Perfect for Compatible Acids, Caustics and D.I. Water
G
REMOVAL CLEARANCE
H
A
ØL
NPT
ØK
B
OUT
I
HEX
CONNECTION NPT
F
C
E
PVF
FLOW
IN
J
D
FEMALE NPT
FLANGE VERSION
G
REMOVAL CLEARANCE
2-1/2
[63.5]
2-1/2
[63.5]
5-23/32
[145.26]
5-23/32
[145.26]
Flowmeters, In-Line
H
A
ØL
NPT
ØK
B HEX
CONNECTION
F
E
OUT
I
NPT
C
IN
D
J
CPF
FEMALE NPT
FLANGE VERSION
Standard (NPT)
Range
00/10
29/40
11/17
41/51
18/22
52/56
23/28
57/62
A
11-1/32
[280.19]
16-15/16
1-1/2˝
[430.21]
24-11/32
3˝
[618.27]
26-43/64
4˝
[728.20]
NPT
3/4˝
B
3-25/64
[86.12]
4-1/4
[107.95]
7-29/32
[200.66]
9-13/16
[248.66]
C
2-53/64
[71.83]
4
[101.6]
7-29/32
[200.66]
9-13/16
[248.66]
D
4-43/64
[118.67]
6-29/64
[163.91]
11-19/32
[294.63]
14-9/32
[362.96]
E
3-39/64
[91.68]
5-1/32
[127.79]
5-1/32
[127.79]
5-7/16
[138.17]
F
2-35/64
[64.69]
3-29/64
[87.71]
4-5/16
[109.22]
5-7/16
[138.17]
G
3
[76.2]
5
[127]
5
[127]
5
[127]
Optional Flange
Option Range
00/10
F1
29/40
11/17
F2
41/51
18/22
F3
52/56
23/28
F4
57/62
186
Flange H
12-1/4
3/4˝
[311.65]
18-5/8
1-1/2˝
[473.19]
22-35/64
3˝
[572.64]
26-3/8
4˝
[669.86]
I
J
4-5/8
4-1/16
[117.6] [103.38]
5-15/16 5-11/16
[151.13] [144.78]
6-7/64 6-7/64
[155.18] [155.18]
7-1/2
7-1/2
[190.5] [190.5]
K
2-3/4
[69.85]
3-7/8
[98.55]
6
[152.4]
7-1/2
[190.5]
VISIT OUR WEBSITES:
L
3-7/8
[98.55]
5
[127]
7-1/2
[190.5]
9
[228.6]
# of Bolt Flange Opening
Holes
Diameter
4
(1-1/8˝)
4
(2˝)
4
(3-1/2˝)
8
(4-1/2˝)
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
187:Layout 2
7/13/11
10:53 AM
Page 1
The Series PVF & CPF Flowmeters are heavy bodied meters for corrosives
and high purity fluids. They are economically priced meters ideal for acids or deionized water making them suited for water & wastewater treatment facilities.
The flowmeters are comprised of all plastic wetted components for maximum
corrosion resistance. They have a full-scale accuracy of ±2% and can be
disassembled quickly without the meter being removed from the pipeline for
easy cleaning. The flowmeters are available with 3/4˝, 1-1/2˝, 3˝, and 4˝ female
NPT connections. Optional flange connections are also available.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: PVF: PVC, fluoroelastomer O-rings; CPF: CPVC,
Buna-N O-rings.
Temperature Limits: See operating limits chart.
Pressure Limits: See operating limits chart.
Accuracy: ±2% of full scale.
Repeatability: ±1/2% of indicated flow rate.
Process Connections: 3/4˝, 1-1/2˝, 3˝, and 4˝ female NPT.
Weight: 3 lb (1.4 kg) for 3/4˝, 9 lb (4.1 kg) for 1-1/2˝, 14 lb (6.4 kg) for
3˝, and 18 lb (8.2) for 4˝.
Water Service
Air Service
Model
PVF-00
PVF-01
PVF-02
PVF-03
PVF-04
PVF-05
PVF-06
PVF-07
PVF-08
PVF-09
PVF-10
PVF-11
PVF-12
PVF-13
PVF-14
PVF-15
PVF-16
PVF-17
PVF-18
PVF-19
PVF-20
PVF-21
PVF-22
PVF-23
PVF-24
PVF-25
PVF-26
PVF-27
PVF-28
Model
CPF-00
CPF-01
CPF-02
CPF-03
CPF-04
CPF-05
CPF-06
CPF-07
CPF-08
CPF-09
CPF-10
CPF-11
CPF-12
CPF-13
CPF-14
CPF-15
CPF-16
CPF-17
CPF-18
CPF-19
CPF-20
CPF-21
CPF-22
CPF-23
CPF-24
CPF-25
CPF-26
CPF-27
CPF-28
Note: For optional flange connections contact the factory.
Range
(SCFM Air)
0.30-7.40
0.50-10.2
0.70-14.0
1.00-20.0
1.00-26.0
1.00-35.0
2.00-50.0
3.00-70.0
4.00-85.0
6.00-125
6.00-160
4.00-260
2.0-40.0
3.00-70.0
4.00-100
5.00-140
5.00-175
6.00-250
2.0-310
7.50-390
10.0-510
35.0-750
20.0-1000
30.0-600
40.0-1000
70.0-1750
100.0-2300
150.0-3500
40.0-1000
70.0-1750
100.0-2300
150.0-3500
150.0-4000
200.0-5000
Connection
(female NPT)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
4˝
4˝
Model
PVF-29
PVF-30
PVF-31
PVF-32
PVF-33
PVF-34
PVF-35
PVF-36
PVF-37
PVF-38
PVF-39
PVF-40
PVF-41
PVF-42
PVF-43
PVF-44
PVF-45
PVF-46
PVF-47
PVF-48
PVF-49
PVF-50
PVF-51
PVF-52
PVF-53
PVF-54
PVF-55
PVF-56
PVF-57
PVF-58
PVF-59
PVF-60
PVF-61
PVF-62
Model
CPF-29
CPF-30
CPF-31
CPF-32
CPF-33
CPF-34
CPF-35
CPF-36
CPF-37
CPF-38
CPF-39
CPF-40
CPF-41
CPF-42
CPF-43
CPF-44
CPF-45
CPF-46
CPF-47
CPF-48
CPF-49
CPF-50
CPF-51
CPF-52
CPF-53
CPF-54
CPF-55
CPF-56
CPF-57
CPF-58
CPF-59
CPF-60
CPF-61
CPF-62
Flowmeters, In-Line
Connection
(female NPT)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
4˝
4˝
FLOW
Range
(GPM Water)
0.025-0.54
0.04-0.80
0.06-1.20
0.08-1.64
0.10-2.60
0.15-3.80
0.20-5.40
0.20-7.00
0.20-10.00
0.60-15.00
0.50-20.0
0.50-11.0
0.70-15.0
1.00-25.0
0.50-35.0
1.00-50.0
2.00-70.0
4.00-120
2.00-50.0
4.00-100
7.00-150
10.0-200
15.0-300
4.00-100
7.00-150
10.0-200
15.0-300
15.0-400
20.0-500
Operating Limits For Series PVF Flowmeters
Maximum Non-Shock Working Pressure, psig @ °F (bar @ °C)
Body Size and Description
3/4˝ PVC-NPT connection
1-1/2˝ PVC-NPT connection
3˝ and 4˝ PVC-NPT connection
3/4˝ PVC-Flange connection
1-1/2˝ PVC-Flange connection
3˝ and 4˝ PVC-Flange connection
70°F (21°C)
250 (17)
170 (11)
160 (11)
150 (10)
150 (10)
150 (10)
80°F (26°C)
255 (15)
150 (10)
150 (10)
150 (10)
150 (10)
150 (10)
100°F (37°C)
150 (10)
105 (7)
105 (7)
150 (10)
105 (7)
105 (7)
120°F (48°C)
90 (6)
65 (4)
65 (4)
65 (4)
65 (4)
65 (4)
140°F (60°C)
50 (3)
40 (2)
40 (2)
50 (3)
40 (2)
40 (2)
120°F (48°C)
200 (10)
145 (10)
125 (9)
135 (9)
135 (9)
135 (9)
140°F (60°C)
150 (10)
115 (8)
105 (7)
110 (8)
110 (8)
110 (8)
Operating Limits For Series CPF Flowmeters
Maximum Non-Shock Working Pressure, psig @ °F (bar @ °C)
Body Size and Description
3/4˝ CPVC-NPT connection
1-1/2˝ CPVC-NPT connection
3˝ and 4˝ CPVC-NPT connection
3/4˝ CPVC-Flange connection
1-1/2˝ CPVC-Flange connection
3˝ and 4˝ CPVC-Flange connection
CALL TO ORDER:
70°F (21°C)
270 (19)
180 (12)
160 (11)
150 (10)
150 (10)
150 (10)
80°F (26°C)
270 (19)
180 (12)
160 (11)
150 (10)
150 (10)
150 (10)
U.S. Phone 219 879-8000
•
100°F (37°C)
250 (17)
170 (11)
140 (10)
150 (10)
150 (10)
150 (10)
U.K. Phone (+44) (0)1494-461707
•
160°F (71°C)
130 (9)
85 (6)
75 (5)
90 (6)
90 (6)
90 (6)
180°F (82°C)
80 (6)
50 (3)
50 (3)
70 (5)
70 (5)
70 (5)
210°F (98°C)
50 (3)
30 (2)
30 (2)
40 (2)
40 (2)
40 (2)
Australia Phone (+61) (0) 2 4272 2055
187
188:Layout 2
7/13/11
10:54 AM
Page 1
Series
P72
P72
Flowmeters
Perfect for Wastewater and Water Treatment Facilities Dealing with Water,
Caustics and Chlorines
2-1/2
[63.5]
REMOVAL
G CLEARANCE
5-23/32
[145.26]
SCALE
A1
A
NPT (AS LISTED)
B
HEX CONNECTION
F
E
NPT
D
FEMALE NPT
(OPTIONAL)
C
P72-A With Optional NPT
FLOW
2-1/2
[63.5]
5-23/32
[145.26]
SCALE
H
ØL
ØK
IN
FLANGE VERSION FOR P72-A/P72-B
(STANDARD)
Flowmeters, In-Line
P72-B With Flange
NPT
3/4˝
1-1/2˝
A
11-1/32
[280.19]
16-15/16
[430.21]
B
3-25/64
[86.12]
4-1/4
[107.95]
NPT OPTION
C
D
2-53/64 4-43/64
[71.83] [118.67]
4
6-29/64
[101.6] [163.91]
E
3-39/64
[91.68]
5-1/32
[127.79]
F
2-35/64
[64.69]
3-29/64
[87.71]
Flange H
12-1/4
3/4˝
[311.65]
1-1/2˝ 18-5/8
[473.19]
22-35/64
3˝
[572.64]
26-3/8
4˝
[669.86]
G
3
[76.2]
5
[127]
The Series P72 Flowmeters are heavy bodied meters for corrosives, gases, and high
purity fluids. These meters are designed specifically for demanding applications. They are
economically priced meters ideal for caustic solutions as well as liquid chlorine, sodium
hypochlorite and chlorine gas. The Series P72 Flowmeters are suited for water treatment
facilities that deal with these aggressive types of gases and fluids. The P72-A is comprised
of P72 and polysulfone, while the P72-B has all P72 wetted components for maximum
corrosion resistance. Units have a full-scale accuracy of ±2% and can be disassembled
quickly without the meter being removed from the pipeline for easy cleaning. The Series
P72 Flowmeters are available with standard 3/4˝, 1-1/2˝, 3˝, and 4˝ flange connections.
Optional NPT connections are also available.
OPERATING LIMITS FOR SERIES P72 FLOWMETERS
Maximum Non-Shock Working Pressure, PSIG @ °F (bar @ °C)
Body Size and Description
3/4˝ P72-NPT connection
1-1/2˝ P72-NPT connection
3/4˝ P72-Flange connection
1-1/2˝ P72-Flange connection
3˝ and 4˝ P72-Flange connection
188
70°F (21°C)
270 (19)
180 (12)
150 (10)
150 (10)
150 (10)
OUT
80°F (26°C)
270 (19)
180 (12)
150 (10)
150 (10)
150 (10)
VISIT OUR WEBSITES:
100°F (37°C)
250 (17)
170 (11)
150 (10)
150 (10)
150 (10)
120°F (48°C)
200 (10)
145 (10)
135 (9)
135 (9)
135 (9)
www.dwyer-inst.com
I
4-5/8
[117.6]
5-15/16
[151.13]
6-7/64
[155.18]
7-1/2
[190.5]
I
J
J
4-1/16
[103.38]
5-11/16
[144.78]
6-7/64
[155.18]
7-1/2
[190.5]
ØK
2-3/4
[69.85]
3-7/8
[98.55]
6
[152.4]
7-1/2
[190.5]
ØL
3-7/8
[98.55]
5
[127]
7-1/2
[190.5]
9
[228.6]
# of
Flange Opening
Bolt Holes Diameter
4
(1-1/8˝)
4
(2˝)
4
(3-1/2˝)
8
(4-1/2˝)
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
P72-A: P72, polysulfone;
P72-B: P72.
Temperature Limits: See operating limits.
Pressure Limits: See operating limits.
Accuracy: ±2% of full scale.
Repeatability: ±1/2% of indicated flow rate.
Process Connections: 3/4˝, 1-1/2˝, 3˝ and 4˝ flange connection with optional NPT
connection available.
Weight: 3 lb (1.4 kg) for 3/4˝, 9 lb (4.1 kg) for 1-1/2˝, 14 lb (6.4 kg) for 3˝, and 18 lb
(8.2 kg) for 4˝.
140°F (60°C)
150 (10)
115 (8)
110 (8)
110 (8)
110 (8)
•
160°F (71°C)
130 (9)
75 (5)
90 (6)
90 (6)
90 (6)
180°F (82°C)
80 (6)
50 (3)
70 (5)
70 (5)
70 (5)
www.dwyer-inst.co.uk
•
210°F (98°C)
50 (3)
30 (2)
40 (2)
40 (2)
40 (2)
www.dwyer-inst.com.au
189:Layout 2
7/13/11
10:55 AM
Model
P72-A000
P72-A001
P72-A002
P72-A003
P72-A004
P72-A005
P72-A006
P72-A007
P72-A008
P72-A009
P72-A010
P72-A011
P72-A012
P72-A013
P72-A014
P72-A015
P72-A016
P72-A017
P72-A018
P72-A019
P72-A020
P72-A021
P72-A022
P72-A023
P72-A024
P72-A025
P72-A026
Range
(GPM Water)
0.025 to 0.54
0.04 to 0.80
0.06 to 1.20
0.08 to 1.64
0.10 to 2.60
0.15 to 3.80
0.20 to 5.40
0.20 to 7.00
0.20 to 10.00
0.60 to 15.00
0.50 to 20.0
0.50 to 11.0
0.70 to 15.0
1.00 to 25.0
0.50 to 35.0
1.00 to 50.0
2.00 to 70.0
4.00 to 120
2.00 to 50.0
4.00 to 100
7.00 to 150
10.0 to 200
15.0 to 300
4.00 to 100
7.00 to 150
10.0 to 200
15.0 to 300
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Model
P72-A184
P72-A185
P72-A186
P72-A187
P72-A188
P72-A189
P72-A190
P72-A191
P72-A192
P72-A193
P72-A194
P72-A195
P72-A196
P72-A197
P72-A198
P72-A199
P72-A200
P72-A201
P72-A202
P72-A203
P72-A204
P72-A205
P72-A206
P72-A207
P72-A208
P72-A209
P72-A210
P72-A211
P72-A212
P72-A213
P72-A214
P72-A215
Range
(SCFM CI2)
0.47 to 11.70
0.79 to 16.10
1.10 to 22.10
1.50 to 31.50
1.50 to 41.00
1.50 to 55.00
3.10 to 78.50
4.70 to 110
6.30 to 134
9.50 to 195
9.50 to 250
6.30 to 410
3.10 to 63
4.73 to 110
6.30 to 157
7.50 to 220
7.50 to 275
9.5 to 394
3.10 to 489
11.8 to 615
15.7 to 804
55.0 to 1180
31.5 to 1575
47.0 to 945
63.0 to 1575
110.0 to 2760
157.0 to 3625
253.0 to 5520
63.0 to 1575
70.0 to 1750
110.0 to 2760
235.0 to 5520
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Model
P72-A058
P72-A059
P72-A060
P72-A061
P72-A062
P72-A063
P72-A064
P72-A065
P72-A066
P72-A067
P72-A068
P72-A069
P72-A070
P72-A071
P72-A072
P72-A073
P72-A074
P72-A075
P72-A076
P72-A077
P72-A078
P72-A079
P72-A080
P72-A081
P72-A082
P72-A083
P72-A084
P72-A085
P72-A086
P72-A087
P72-A088
P72-A089
Range
(SCFM Air)
0.30 to 7.40
0.50 to 10.2
0.70 to 14.0
1.00 to 20.0
1.00 to 26.0
1.00 to 35.0
2.00 to 50.0
3.00 to 70.0
4.00 to 85.0
6.00 to 125
6.00 to 160
4.00 to 260
2.0 to 40.0
3.00 to 70.0
4.00 to 100
5.00 to 140
5.00 to 175
6.00 to 250
2.0 to 310
7.50 to 390
10.0 to 510
35.0 to 750
20.0 to 1000
30.0 to 600
40.0 to 1000
70.0 to 1750
100.0 to 2300
150.0 to 3500
40.0 to 1000
70.0 to 1750
100.0 to 2300
150.0 to 3500
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Model
P72-A252
P72-A253
P72-A254
P72-A255
P72-A256
P72-A257
P72-A258
P72-A259
P72-A260
P72-A261
P72-A262
P72-A263
P72-A264
P72-A265
P72-A266
P72-A267
P72-A268
P72-A269
P72-A270
P72-A271
P72-A272
P72-A273
P72-A274
P72-A275
P72-A276
P72-A277
P72-A278
P72-A279
P72-A280
P72-A281
P72-A282
P72-A283
Range
(SCFM NaOH)
0.44 to 10.75
0.70 to 14.75
1.00 to 20.40
1.45 to 29.15
1.45 to 37.90
1.45 to 51.50
2.92 to 72.90
4.38 to 102.10
5.80 to 124
8.75 to 182
8.75 to 233
5.80 to 379
2.90 to 58.40
4.38 to 102
5.80 to 145
7.30 to 204
7.30 to 255
8.75 to 365
2.9 to 450
10.9 to 565
14.5 to 740
51.1 to 1090
29.0 to 1450
44.0 to 875
58.4 to 1450
102.1 to 2550
145 to 3350
218.8 to 5105
58.4 to 1450
102.1 to 2550
145 to 3350
218.8 to 5105
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Model
P72-A320
P72-A321
P72-A322
P72-A323
P72-A324
P72-A325
P72-A326
P72-A327
P72-A328
P72-A329
P72-A330
P72-A331
P72-A332
P72-A333
P72-A334
P72-A335
P72-A336
P72-A337
P72-A338
P72-A339
P72-A340
P72-A341
P72-A342
P72-A343
P72-A344
P72-A345
P72-A346
Range
(GPM NaOCRl)
0.03 to 0.65
0.05 to 0.90
0.07 to 1.35
0.09 to 1.85
0.10 to 2.93
0.17 to 4.28
0.23 to 6.08
0.23 to 7.89
0.23 to 11.27
0.68 to 16.90
0.56 to 22.54
0.56 to 12.4
0.79 to 16.9
1.13 to 28.2
0.56 to 39.4
1.13 to 56.3
2.25 to 78.9
4.50 to 135
2.25 to 56.3
4.50 to 113
7.9 to 169
11.3 to 225
16.9 to 338
4.50 to 112
7.9 to 169
11.2 to 225
16.9 to 338
Connection
(Flange)
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
3/4˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
1-1/2˝
3˝
3˝
3˝
3˝
3˝
4˝
4˝
4˝
4˝
Flowmeters, In-Line
Range
(GPM CI)
0.03 to 0.62
0.05 to 0.92
0.07 to 1.39
0.09 to 1.89
0.12 to 3.00
0.17 to 4.39
0.23 to 6.24
0.23 to 8.08
0.23 to 11.55
0.69 to 17.32
0.58 to 23.09
0.58 to 12.50
0.81 to 17.00
1.15 to 28.50
0.58 to 40.00
1.15 to 57.50
2.30 to 80.50
4.50 to 138.50
2.30 to 57.50
4.62 to 115
8.10 to 175
11.5 to 230
17.0 to 350
4.60 to 115
8.10 to 175
11.5 to 230
17.0 to 350
FLOW
Model
P72-A126
P72-A127
P72-A128
P72-A129
P72-A130
P72-A131
P72-A132
P72-A133
P72-A134
P72-A135
P72-A136
P72-A137
P72-A138
P72-A139
P72-A140
P72-A141
P72-A142
P72-A143
P72-A144
P72-A145
P72-A146
P72-A147
P72-A148
P72-A149
P72-A150
P72-A151
P72-A152
Page 1
Note: For all P72 construction, change “A” to “B”. Consult website or factory for ordering code and pricing.
Meters available with optional 3/4˝ and 1-1/2˝ female NPT connections instead of flange.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
189
190:Layout 2
7/13/11
10:55 AM
Page 1
Series
DS
In-Line Flow Sensors
®
Use with the Dwyer Differential Pressure Gages or Transmitters
Valves — Standard, brass with TFE
seat and Buna-N O-ring
1-15/16 [49.21]
Nameplate —
Stainless steel
permanently attached
with split ring. Includes
complete size and
model information.
1-5/8 [41.28]
1-3/4 [44.45]
1-11/16 [42.86] APPROX
Head — Machined stainless steel.
1/4 NPT
1-7/16 [36.53]
Packing gland — Parker CPI brass
compression fitting.
5/16 [7.94]
FLOW
Sensor tube — 304 SS.
Flow Sensors, In-Line
Model DS-300
1/16 [1.59] CLEARANCE
Sensing ports — Multiple upstream and
downstream ports sized and positioned
to provide effective accurate pressure
averaging, even at lower velocities.
In-Line Flow Sensors are averaging Pitot tubes that provide accurate and
convenient flow rate sensing for schedule 40 pipe. When purchased with a
Dwyer® Capsuhelic® differential pressure gage of appropriate range, the result
is a flow indicating system delivered off the shelf at an economical price.
Pitot tubes have been used in flow measurement for years. Conventional pitot
tubes sense velocity pressure at only one point in the flowing stream. Therefore,
a series of measurements must be taken across the stream to obtain a
meaningful average flow rate. The Dwyer® flow sensor eliminates the need for
“traversing” the flowing stream because of its multiple sensing points and builtin averaging capability.
Select model with suffix which matches pipe size
Model DS-300-1˝
Model DS-300-1-1/4˝
Model DS-300-1-1/2˝
Model DS-300-2˝
Model DS-300-2-1/2˝
Model DS-300-3˝
Model DS-300-4˝
Model DS-300-6˝
Model DS-300-8˝
Model DS-300-10˝
The Series DS-300 flow sensors are designed to be inserted in the pipeline
through a compression fitting. They are furnished with instrument shut-off
valves on both pressure connections. Valves are fitted with 1/8˝ female NPT
connections. Accessories include adapters with 1/4˝ SAE 45° flared ends
compatible with hoses supplied with the Model A-471 Portable Capsuhelic® gage
kit. Standard valves are rated at 200 psig (13.7 bar) and 200°F (93.3°C). Where
valves are not required, they can be omitted at reduced cost. Series DS-300 flow
sensors are available for pipe sizes from 1˝ to 10˝.
Model DS-400-6˝
Model DS-400-8˝
Model DS-400-10˝
Model DS-400-12˝
Model DS-400-14˝
Model DS-400-16˝
Model DS-400-18˝
Model DS-400-20˝
Model DS-400-24˝
DS-400 Averaging Flow Sensors are quality constructed from extra strong
3/4˝ dia. stainless steel to resist increased forces encountered at higher flow
rates with both air and water. This extra strength also allows them to be made
in longer insertion lengths up to 24 inches (61 cm). All models include
convenient and quick-acting quarter-turn ball valves to isolate the sensor for
zeroing. Process connections to the valve assembly are 1/8˝ female NPT. A pair
of 1/8˝ NPT X 1/4˝ SAE 45° flared adapters are included, compatible with
hoses used in the Model A-471 Portable Capsuhelic® Gage Kit. Supplied solid
brass mounting adapter has a 3/4˝ dia. compression fitting to lock in required
insertion length and a 3/4˝ male NPT thread for mounting in a Threaded
Branch Connection.
190
VISIT OUR WEBSITES:
www.dwyer-inst.com
OPTIONS & ACCESSORIES
DS-300 or DS-400 Less Valves. To order, add suffix -LV
A-160, Threaded Branch Connection, 3/8˝ NPT, forged steel, 3000 psi
A-161, Brass Bushing, 1/4˝ x 3/8˝
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
191:Layout 2
7/13/11
10:57 AM
Page 1
How To Order
Large 3/4 Inch Diameter for Extra Strength
in Lengths to 24 Inches
2-1/16
[52.40]
1-5/8 [41.28] TYP.
LP
2-1/8 [53.98]
HP
3-5/8 [92.08] APPROX.
3/4 [19.05]
DIA.
1/16 [1.60]
GAP UP TO 12˝ PIPE
1/8 [3.175]
GAP 14˝ PIPE AND UP
72-700416-00
FLOW
Merely determine the pipe size into which the flow sensor will be mounted
and designate the size as a suffix to Model DS-300. For example, a flow
sensor to be mounted in a 2˝ pipe would be a Model No. DS-300-2˝.
For non-critical water and air flow monitoring applications, the chart below
can be utilized for ordering a stock Capsuhelic® differential pressure gage
for use with the DS-300 flow sensor. Simply locate the maximum flow rate
for the media being measured under the appropriate pipe size and read
the Capsuhelic® gage range in inches of water column to the left. The DS300 sensor is supplied with installation and operating instructions, Bulletin
F-50. It also includes complete flow conversion information for the three
media conditions shown in the chart below. This information enables the
user to create a complete differential pressure to flow rate conversion table
for the sensor and differential pressure gage employed. Both the Dwyer®
Capsuhelic® gage and flow sensor feature excellent repeatability so, once
the desired flow rate is determined, deviation from that flow in quantitative
measure can be easily determined. You may wish to order the adjustable
signal flag option for the Capsuhelic® gage to provide an easily identified
reference point for the proper flow.
Capsuhelic® gages with special ranges and/or direct reading scales in
appropriate flow units are available on special order for more critical
applications. Customer supplied data for the full scale flow (quantity and
units) is required along with the differential pressure reading at that full
flow figure. Prior to ordering a special Capsuhelic® differential pressure
gage for flow read-out, we recommend you request Bulletin F-50 to obtain
complete data on converting flow rates of various media to the sensor
differential pressure output. With this bulletin and after making a few
simple calculations, the exact range gage required can easily be
determined.
DS-400
1˝
4.8
19.0
50.0
7.7
30.0
83.0
11.0
41.0
120.0
18.0
63.0
185.0
25.0
90.0
260.0
36.5
135.0
370.0
Full Range Flows by Pipe Size (Approximate)
1-1/4˝ 1-1/2˝ 2˝
2-1/2˝ 3˝
4˝
6˝
8˝
8.3
11.5 20.5
30
49
86
205
350
33.0 42.0 65.0
113
183 330 760
1340
90.5 120.0 210.0 325
510 920 2050 3600
14.0 18.0 34.0
47
78
138 320
560
51.0 66.0 118.0 178
289 510 1200 2150
142.0 190.0 340.0 610
820 1600 3300 5700
19.0 25.5 45.5
67
110 195 450
800
72.0 93.0 163.0 250
410 725 1690 3040
205.0 275.0 470.0 740
1100 2000 4600 8100
32.0 40.5 72.0
108
173 310 720
1250
112.0 155.0 255.0 390
640 1130 2630 4860
325.0 430.0 760.0 1200 1800 3300 7200 13000
44.0 57.5 100.0 152
247 435 1000 1800
161.0 205.0 360.0 560
900 1600 3700 6400
460.0 620.0 1050.0 1700 2600 4600 10000 18500
62.0 82.0 142.0 220
350 620 1500
230.0 300.0 505.0 800
1290 2290 5000
660.0 870.0 1500.0 2300 3600 6500 15000
10˝
560
2130
6000
890
3400
10000
1260
4860
15000
2000
7700
22000
Flow Sensors, In-Line
Gage Range Media
(in w.c.)
@ 70°F
2
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
5
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
10
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
25
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
50
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
100
Water (GPM)
Air @ 14.7 PSIA (SCFM)
Air @ 100 PSIG (SCFM)
Model A-471 Portable Kit
The Dwyer® Series 4000 Capsuhelic® differential pressure gage is ideally
suited for use as a read-out device with the DS-300 Flow Sensors. The gage
may be used on system pressures of up to 500 psig even when the flow sensor
differential pressure to be read is less than 0.5˝ w.c. With accuracy of ±3% of
full scale, the Capsuhelic® gage can be used in ambient temperatures from 32
to 200°F (0 to 93.3°C). Zero and range adjustments are made from outside the
gage. The standard gage with a die cast aluminum housing can be used with
the flow sensor for air or oil applications. For water flow measurements, the
optional forged brass housing should be specified. The Capsuhelic® gage may
be panel or surface mounted and permanently plumbed to the flow sensor
if desired. The optional A-610 pipe mounting bracket allows the gage to be
easily attached to any 1-1/4˝- 2˝ horizontal or vertical pipe.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
For portable operation, the A471 Capsuhelic® Portable
Gage Kit is available complete
with tough polypropylene
carrying case, mounting
bracket, 3-way manifold valve,
two 10' high pressure hoses,
and all necessary fittings.
See pages 10 and 11 for
complete information on the
Capsuhelic® gage
U.K. Phone (+44) (0)1494-461707
•
Capsuhelic® Gage Shown
Instaled In A-471 Portable Kit
Australia Phone (+61) (0) 2 4272 2055
191
192:Layout 2
7/13/11
10:58 AM
Page 1
Series
OP
Orifice Plate Flowmeter
Stainless Steel for Use with Liquids and Gases
1/4˝ NPT PRESSURE FITTING
A
CL
ORIFICE PLATE
1/8 [3.18]
THICK TYPICAL
HI
PRESSURE
4-1/2 OD
[114.3]
ID
FLOW
A
Flowmeters, Orifice Plate
FLOW
BODY
(CARRIER RING)
CL
LOW
PRESSURE
INCLUDES RING GASKET
ADHERED TO FACES
SPECIFICATIONS
Service: For metering compatible liquids and gases.
Wetted Material: 304 SS, Buna-N gaskets.
Accuracy: 0.6% of full scale flow. (Beta = .2-.6) ±0.7% for Beta
greater than .6.
Temperature Limits: -50 to 200°F (-45 to 93°C).
Pressure Limits: Limited only by pipe and flange rating restrictions.
Head Loss: 1-Beta ratio2 eg: 1-0.72 = 1-0.49 = 51% of the d.p.
Line Sizes: 1/2˝ to 24˝.
Process Connection: 1/4˝ female NPT.
Installation: Standard flange, any rating (orifice flanges not
required).
Pipe Requirements: General requirements 10 diameter upstream
and 5 diameter downstream of orifice plate.
Weight: Varies with line size. See chart.
The Series OP Orifice Plate Flow Meter is a complete orifice plate
flow metering package. It incorporates a stainless steel orifice plate with
a unique holder or carrier ring containing metering taps and integral
gaskets. It was designed for use wherever there is an application for a
conventional flow orifice plate. It can also be used in place of other
primary differential producers for efficiency and cost effectiveness.
Installation is accomplished simply by slipping the unit between standard
flanges (orifice flanges are not required). The Series OP is available in
line sizes from 1/2˝ to 24˝ and can be used with compatible liquids and
gases.
FEATURES
• Mounted with standard flanges
• Corner type metering taps
• Corrosion free material
• Simplified installation
• Stainless steel wetted parts
• Proven through a wide range of applications for energy
efficiency
• Assures long term reliability and accuracy
APPLICATION
Fluid flow rates in building water lines.
192
VISIT OUR WEBSITES:
www.dwyer-inst.com
1-1/4
[31.75]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
193:Layout 2
7/13/11
11:01 AM
Page 1
Series OP Orifice Plate Flowmeter
• Material 304/304 L- dual certified- Gaskets Buna-N
• Based on 70°F, 14.7 psia (Base Conditions)
• Beta Value Based on Std Sch pipe I.D.
• 1.25˝ overall thickness
• Orifice plate thickness is 0.125˝
Water Capacity
Air Capacity - Flow in SCFM
Inch d.p. at 14.7 psia
W/C
(0 psig)
at 20 psig
at 100 psig
OP-A-1
OP-A-2
OP-A-3
1.00
1.00
1.00
1/2˝
1/2˝
1/2˝
0.200˝
0.310˝
0.430˝
0.32
0.50
0.69
20
100
320
0.62
3.44
13.00
20
100
200
2.35
12.21
32.77
3.63
19.58
56.15
6.61
36.37
107.47
OP-B-1
OP-B-2
OP-B-3
1.00
1.00
1.00
3/4˝
3/4˝
3/4˝
0.250˝
0.400˝
0.580˝
0.30
0.49
0.70
20
100
320
0.97
5.69
23.82
20
100
200
3.65
20.21
59.92
5.66
32.44
102.91
10.3
60.26
197.2
OP-C-1
OP-C-2
OP-C-3
2.00
2.00
2.00
1˝
1˝
1˝
0.300˝
0.520˝
0.720˝
0.29
0.49
0.69
20
100
320
1.38
9.63
36.15
20
100
200
5.24
34.2
91.28
8.11
54.92
156.51
14.8
102.09
300
OP-D-1
OP-D-2
OP-D-3
2.00
2.00
2.00
1.25˝ 0.400˝
1.25˝ 0.700˝
1.25˝ 1.00˝
0.29
0.51
0.72
20
100
320
2.46
17.48
71.77
20
100
200
9.31
62.09
180
14.41
99.75
309.97
26.3
185.5
595.2
OP-E-1
OP-E-2
OP-E-3
2.00
2.00
2.00
1.5˝
1.5˝
1.5˝
0.500˝
0.800˝
1.100˝
0.31
0.50
0.68
20
100
320
3.85
22.73
83.95
20
100
200
14.57
80.82
212.18
22.55
129.68
363.93
41.16
241.5
697.39
OP-F-1
OP-F-2
OP-F-3
3.00
3.00
3.00
2˝
2˝
2˝
0.600˝
1.000˝
1.450˝
0.29
0.48
0.70
20
100
320
5.52
35.34
147.74
20
100
200
20.92
125.74
372.09
32.38
202.03
639.87
59.13
375.8
1227.63
OP-G-1
OP-G-2
OP-G-3
4.00
4.00
4.00
2.5˝
2.5˝
2.5˝
0.750˝
1.250˝
1.750˝
0.30
0.50
0.70
20
100
320
8.63
55.54
216.30
20
100
200
32.71
197.54
543.99
50.64
317.58
936.56
92.48
590.91
1798.86
OP-H-1
OP-H-2
OP-H-3
5.00
5.00
5.00
3˝
3˝
3˝
0.920˝
1.500˝
2.150˝
0.30
0.49
0.70
20
100
320
12.97
79.94
324.16
20
100
200
49.17
282.9
816.7
76.13
454.77
1404.95
139.06
846.21
2696.28
OP-J-1
OP-J-2
OP-J-3
7.00
7.00
7.00
4˝
4˝
4˝
1.200˝
2.000˝
2.800˝
0.30
0.50
0.70
20
100
320
22.03
141.51
547.11
20
100
200
83.58
503.76
1380.03
129.44
810.06
2373.02
236.48
1507.64
4553.68
OP-K-1
OP-K-2
OP-K-3
8.00
8.00
8.00
5˝
5˝
5˝
1.500˝
2.500˝
3.500˝
0.30
0.50
0.69
20
100
320
34.39
220.80
853.09
20
100
200
130.48
786.23
2152.83
202.11
1264.42
3701.57
369.29
2353.51
7103.22
OP-L-1
OP-L-2
OP-L-3
10.00
10.00
10.00
6˝
6˝
6˝
1.800˝
3.000˝
4.200˝
0.30
0.49
0.69
20
100
320
49.46
317.74
1226.98
20
100
200
187.86
1331.63
3097.20
291
1820.05
5325.20
531.75
3387.93
10219.28
OP-M-1
OP-M-2
OP-M-3
14.00
14.00
14.00
8˝
8˝
8˝
2.400˝
4.000˝
5.600˝
0.30
0.50
0.70
20
100
320
87.95
565.77
2195.86
20
100
200
333.87
2014.95
5532.00
517.25
3241.45
9525.43
945.28
6034.85
18290.00
OP-N-1
OP-N-2
OP-N-3
20.00
20.00
20.00
10˝
10˝
10˝
3.000˝
5.000˝
7.000˝
0.30
0.50
0.70
20
100
320
137.35
883.04
3421.26
20
100
200
521.58
3145.50
8626.42
808
5060.38
14846.80
1476.77
9421.74
28506.17
OP-O-1
OP-O-2
OP-O-3
30.00
30.00
30.00
12˝
12˝
12˝
3.600˝
6.000˝
8.400˝
0.30
0.50
0.70
20
100
320
197.73
1271.62
4930.86
20
100
200
750.9
4530
12430.00
1163.44
7288.16
21397.00
2126.47
13570.33
41089.02
OP-P-1
OP-P-2
OP-P-3
40.00
40.00
40.00
14˝
14˝
14˝
4.000˝
6.600˝
9.300˝
0.30
0.50
0.70
20
100
320
244.14
1537.49
6052.57
20
100
200
927.14
6477.67
15251.50
1436.59
8812.87
28262.66
2625.81
16409.42
50427.78
OP-Q-1
OP-Q-2
OP-Q-3
48.00
48.00
48.00
16˝
16˝
16˝
4.500˝ 0.30
7.600˝ 0.50
10.700˝ 0.70
20
100
320
308.76
2038.95
8007.74
20
100
200
1172.63
7264.58
20179.85
1817.05
11688.26
34749.32
3321.32
21764.08
66737.64
Flowmeters, Orifice Plate
Inch d.p. Flow in
Beta W/C
GPM
FLOW
Model
Weight Line
(lb)
Size Bore
Note: Differential pressure values should be less than 50% of the inlet absolute pressure.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
193
194:Layout 2
7/13/11
11:01 AM
Page 1
Series
PE
&
TE
Orifice Plate Flowmeter
PVC or PTFE Orifice Plates
1/4˝ NPT PRESSURE FITTING
A
CL
ORIFICE PLATE
1/8 [3.18]
THICK TYPICAL
HI
PRESSURE
4-1/2 OD
[114.3]
ID
FLOW
PE
A
BODY
(CARRIER RING)
CL
LOW
PRESSURE
INCLUDES RING GASKET
ADHERED TO FACES
1-1/4
[31.75]
Flowmeters, Orifice Plate
FLOW
TE
SPECIFICATIONS
Service: PE: Clean air and compatible gases; TE: Compatible gases and liquids.
Wetted Material: Monolithic (single piece) constructed entirely of gray PVC for PE
or white PTPE for TE, Buna-N gaskets.
Accuracy: ±0.6% full scale flow. (Beta = .2-.6) ±0.7% for Beta greater than .6.
Temperature Limits: PE: 140°F max (60°C max); TE: -40 to 200°F (-40 to 93.3°C).
Pressure Limits: 150 psi (10 bar) max.
Head Loss: 1-Beta ratio2 eg: 1 - 0.72 = 1 - 0.49 = 51% of the d.p.
Line Sizes: 1/2˝ to 24˝.
Process Connections: 1/4˝ female NPT.
Installation: Standard flange 125#/150# rating.
Pipe Requirements: General requirements 10 diameter upstream and 5 diameter
downstream.
Weight: Varies with line size. See chart.
The Series PE Orifice Plate Flow Meter offers one-piece PVC construction incorporating
a unique holder or carrier ring containing metering taps and integral gaskets. Unlike a
standard orifice plate, the Series PE is a true primary element including the various
components for differential pressure measurement. It was designed for use wherever there
is an application for a conventional flow orifice plate. It can also be used in place of other
primary differential producers for efficiency and cost effectiveness. The Series PE is available
in line sizes from 1/2˝ to 24˝ and used for air and most gases. It meets or exceeds ASME,
AGA & ISO standards.
SERIES PE FEATURES
• Mounted with standard flanges
• Standard “corner tap” configuration
• Corrosion free material
• Simplified installation
• Built in metering taps (1/4˝ female NPT STD)
• Proven through a wide range of applications for accuracy and energy efficiency
• Assures long term reliability and accuracy
The Series TE Orifice Plate Flowmeter offers one-piece PTFE construction similar to
the OP and PE Series orifice plates, which incorporate a unique holder or carrier ring
containing metering taps and integral gaskets. Available for line sizes from 1/2˝ to 24˝, the
Series TE orifice plate can be used with gases, liquids, corrosive, and high temperature
fluids. The Series TE can be easily installed by slipping the unit between standard flanges
(orifice flanges are not required). The Series TE was designed for use anywhere there is
an application for a conventional flow orifice plate. It can also be used in place of other
primary differential producers for efficiency and cost effectiveness.
SERIES TE FEATURES
• Excellent chemical resistance
• Weather resistant
• Flame retardant (without factory gaskets)
• Low friction (minimum wear)
• Orifice plate thickness 1/4˝ offering greater stability
194
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
195:Layout 2
7/13/11
11:04 AM
Page 1
Series PE Orifice Plate Flowmeter – Air Capacity Structure
• Material PVC- Gaskets Buna-N
• Based on 70°F, 14.7 psia (Base Conditions)
• Beta Value Based on Std Sch pipe I.D.
• 1.25˝ overall thickness
• Orifice plate thickness is 0.125˝
PE
Weight
(lb)
1.00
1.00
1.00
Series TE Orifice Plate Flowmeter – Capacity Structure
• Material PTFE - Gaskets Buna-N
• Based on 70°F, 14.7 psia (base conditions)
• Beta value based on Std Sch pipe I.D.
• 1.25˝ overall thickness
• Orifice plate thickness is 0.250˝
Line
Size
1/2˝
1/2˝
1/2˝
Bore
0.200˝
0.310˝
0.430˝
Beta
0.3
0.5
0.69
Water Capacity (TE)
Inch d.p. Flow in
GPM
W/C
0.62
20
3.44
100
13.00
320
PE-B-1 1.00
PE-B-2 1.00
PE-B-3 1.00
TE-B-1
TE-B-2
TE-B-3
1.00
1.00
1.00
3/4˝
3/4˝
3/4˝
0.250˝
0.400˝
0.580˝
0.3
0.49
0.7
20
100
320
0.97
5.69
23.82
20
100
200
PE-C-1 1.00
PE-C-2 1.00
PE-C-3 1.00
TE-C-1
TE-C-2
TE-C-3
1.00
1.00
1.00
1˝
1˝
1˝
0.300˝
0.520˝
0.720˝
0.29
0.49
0.69
20
100
320
1.38
9.63
36.15
PE-D-1 1.00
PE-D-2 1.00
PE-D-3 1.00
TE-D-1
TE-D-2
TE-D-3
1.00
1.00
1.00
1.25˝
1.25˝
1.25˝
0.400˝
0.700˝
1.00˝
0.29
0.51
0.72
20
100
320
PE-E-1 2.00
PE-E-2 2.00
PE-E-3 2.00
TE-E-1
TE-E-2
TE-E-3
2.00
2.00
2.00
1.5˝
1.5˝
1.5˝
0.500˝
0.800˝
1.100˝
0.31
0.5
0.68
PE-F-1 2.00
PE-F-2 2.00
PE-F-3 2.00
TE-F-1
TE-F-2
TE-F-3
2.00
2.00
2.00
2˝
2˝
2˝
0.600˝
1.000˝
1.450˝
PE-G-1 2.00
PE-G-2 2.00
PE-G-3 2.00
TE-G-1
TE-G-2
TE-G-3
2.00
2.00
2.00
2.5˝
2.5˝
2.5˝
PE-H-1 2.00
PE-H-2 2.00
PE-H-3 2.00
TE-H-1
TE-H-2
TE-H-3
2.00
2.00
2.00
PE-J-1 3.00
PE-J-2 3.00
PE-J-3 3.00
TE-J-1
TE-J-2
TE-J-3
PE-K-1 3.00
PE-K-2 3.00
PE-K-3 3.00
Air Capacity - Flow in SCFM
Inch d/p
at 14.7 psia
W/C
(0 psig)
20
2.35
100
12.21
200
32.77
at 20 psig
3.63
19.58
56.15
at 100 psig
6.61
36.37
107.47
3.65
20.21
59.92
5.66
32.44
102.91
10.3
60.26
197.2
20
100
200
5.24
34.2
91.28
8.11
54.92
156.51
14.8
102.09
300
2.46
17.48
71.77
20
100
200
9.31
62.09
180
14.41
99.75
309.97
26.3
185.5
595.2
20
100
320
3.85
22.73
83.95
20
100
200
14.57
80.82
212.18
22.55
129.68
363.93
41.16
241.5
697.39
0.29
0.48
0.7
20
100
320
5.52
35.34
147.74
20
100
200
20.92
125.74
372.09
32.38
202.03
639.87
59.13
375.8
1227.63
0.750˝
1.250˝
1.750˝
0.3
0.5
0.7
20
100
320
8.63
55.54
216.30
20
100
200
32.71
197.54
543.99
50.64
317.58
936.56
92.48
590.91
1798.86
3˝
3˝
3˝
0.920˝
1.500˝
2.150˝
0.3
0.49
0.7
20
100
320
12.97
79.94
324.16
20
100
200
49.17
282.9
816.7
78.13
454.77
1404.95
139.06
846.21
2696.28
3.00
3.00
3.00
4˝
4˝
4˝
1.200˝
2.000˝
2.800˝
0.3
0.5
0.7
20
100
320
22.03
141.51
547.11
20
100
200
83.58
503.76
1380.03
129.44
810.06
2373.02
236.48
1507.64
4553.68
TE-K-1
TE-K-2
TE-K-3
4.00
4.00
4.00
5˝
5˝
5˝
1.500˝
2.500˝
3.500˝
0.3
0.5
0.69
20
100
320
34.39
220.80
853.09
20
100
200
130.48
786.23
2152.83
202.11
1264.42
3701.57
369.29
2353.51
7103.22
PE-L-1 4.00
PE-L-2 4.00
PE-L-3 4.00
TE-L-1
TE-L-2
TE-L-3
4.00
4.00
4.00
6˝
6˝
6˝
1.800˝
3.000˝
4.200˝
0.3
0.49
0.69
20
100
320
49.46
317.74
1226.98
20
100
200
187.86
1331.63
3097.20
291
1820.05
5325.20
531.75
3387.93
10219.28
PE-M-1 5.00
PE-M-2 5.00
PE-M-3 5.00
TE-M-1 6.00
TE-M-2 6.00
TE-M-3 6.00
8˝
8˝
8˝
2.400˝
4.000˝
5.600˝
0.3
0.5
0.7
20
100
320
87.95
565.77
2195.86
20
100
200
333.87
2014.95
5532.00
517.25
3241.45
9525.43
945.28
6034.85
18290.00
PE-N-1 6.00
PE-N-2 6.00
PE-N-3 6.00
TE-N-1
TE-N-2
TE-N-3
8.00
8.00
8.00
10˝
10˝
10˝
3.000˝
5.000˝
7.000˝
0.3
0.5
0.7
20
100
320
137.35
883.04
3421.26
20
100
200
521.58
3145.50
8626.42
808
5060.38
14846.80
1476.77
9421.74
28506.17
PE-O-1 7.00
PE-O-2 7.00
PE-O-3 7.00
TE-O-1
TE-O-2
TE-O-3
10.00
10.00
10.00
12˝
12˝
12˝
3.600˝
6.000˝
8.400˝
0.3
0.5
0.7
20
100
320
197.73
1271.62
4930.86
20
100
200
750.9
4530
12430.00
1163.44
7288.16
21397.00
2126.47
13570.33
41089.02
PE-P-1 9.00
PE-P-2 9.00
PE-P-3 9.00
TE-P-1
TE-P-2
TE-P-3
15.00
15.00
15.00
14˝
14˝
14˝
4.000˝
6.600˝
9.300˝
0.3
0.5
0.7
20
100
320
244.14
1537.49
6052.57
20
100
200
927.14
5477.67
15251.50
1436.59
8812.87
28262.66
2625.81
16409.42
50437.78
PE-Q-1 10.00
PE-Q-2 10.00
PE-Q-3 10.00
TE-Q-1
TE-Q-2
TE-Q-3
18.00
18.00
18.00
16˝
16˝
16˝
4.500˝
7.600˝
10.700˝
0.3
0.5
0.7
20
100
320
308.76
2038.95
8007.74
20
100
200
1172.63
7264.58
20179.85
1817.05
11688.26
34749.32
3321.32
21764.08
66737.64
Flowmeters, Orifice Plate
TE
Weight
(lb)
1.00
1.00
1.00
FLOW
TE
Model
TE-A-1
TE-A-2
TE-A-3
PE
Model
PE-A-1
PE-A-2
PE-A-3
Note: Differential pressure values should be less than 50% of the inlet absolute pressure.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
195
196:Layout 2
7/13/11
11:04 AM
Page 1
Series
SFI-100, SFI-300,
SFI-350, SFI-360,
SFI-400, SFI-700
MIDWEST Sight Flow Indicators
Inexpensive Protection for Expensive Equipment and Systems
Model 100, 100MP
Model 400
Sight Flow Indicators
FLOW
Model 300, 300MP
Model 360F
Model 700
Sight Flow Indicator Dimensions and Weight
Midwest Sight Flow Indicators are manufactured of quality materials and safety tested to
assure long, dependable service at economical prices. Available in window viewing style in the
100 and 300 Series and tube viewing style in the 400 and 700 Series with connection choices
of female NPT, BSPP, or BSPT threaded and flanged. Series 700 has impeller and internal
wipers for cleaning sight tube, which is perfect for fluids with suspended solids. Just rotate the
glass tube and restore full 360° visibility without disrupting the flow.
Body
Model Size Length
1/4, 3/8 3.000 (76)
100
Series 1/2, 3/4 4.000 (102)
1, 1-1/4 4.375 (111)
1-1/2, 2 5.688 (144)
1/4, 3/8 3.063 (78)
300
Series 1/2, 3/4 4.063 (103)
1, 1-1/4 4.375 (111)
1-1/2, 2 5.500 (140)
1/4, 3/8 2.750 (70)
700
Series 1/2, 3/4 3.688 (94)
1, 1-1/4, 4.875 (124)
1-1/2
1/2
4.500 (144)
400
5.125 (130)
Series 3/4
1
5.625 (143)
1-1/4 5.750 (146)
1-1/2 5.875 (149)
2
6.125 (156)
3
6.250 (159)
4
6.250 (159)
400F 1
5.000 (127)
Series 1-1/4 5.125 (130)
1-1/2 5.250 (133)
2
5.370 (137)
3
5.750 (146)
4
5.750 (146)
300F 1-1/2 6.375 (162)
Series 2
6.500 (165)
3
8.875 (225)
4
10.250 (260)
6
12.500 (318)
Models
• 100 - Single window with impeller
• 300 - Double window with impeller
• 350 - Double window with no indicator
• 360 - Double window with flapper
• 400 - Tube type with no indicator
• 700 - Tube type with impeller and internal wipers to clean glass tube
Flange
Depth
Height
Diameter
1.813 (46) 2.125 (54) 2.250 (57) 2.563 (65) 2.563 (65) 2.625 (67) 3.250 (830) 3.625 (83) 2.250 (57) 2.125 (54) 2.750 (70) 2.563 (65) 3.125 (79) 2.563 (65) 3.688 (93) 4.063 (103) 1.500 (38) 2.250 (57) 2.750 (70) (across flats) 3.500 (89)
3.875 (98)
4.250 (108)
4.625 (117)
5.000 (127)
6.000 (152)
7.500 (191)
9.00 (229)
4.250 (108)
4.625 (117)
5.000 (127)
6.000 (152)
7.500 (191)
9.000 (229)
5.000 (127)
6.000 (152)
7.500 (191)
9.000 (229)
11.000 (279)
Viewing
Weight
Area
Diameter lb (kg)
1.1 (0.5)
1.5 (0.7)
2.7 (1.2)
5.5 (2.5)
1.7 (0.8)
2.6 (1.2)
3.0 (1.4)
7.0 (3.2)
0.9 (0.4)
2.4 (1.1)
5.1 (2.3)
1.500 (38) 3.8 (1.7)
1.750 (44) 4.8 (2.2)
2.000 (51 ) 6.2 (2.8)
2.000 (51) 7.6 (3.5)
2.500 (64) 8.7 (4.0)
3.000 (76) 13 (6.0)
4.000 (102) 17 (7.7)
5.000 (127) 25 (11.0)
2.000 (51) 7 (3.2)
2.000 (51) 8 (3.6)
2.500 (64) 12 (5.5)
3.000 (76) 14 (6.4)
4.000 (102) 23 (10.4)
5.000 (127) 31 (14.1)
2.313 (58) 12 (5.5)
2.313 (58) 16 (7.5)
3.000 (76) 38 (17)
4.000 (102) 56 (25)
6.000 (152) 120 (55)
Dimensions are in inches (mm)
196
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
197:Layout 2
7/13/11
11:05 AM
Page 1
SFI-100 & SFI-300 SERIES
Window Style with Threaded Connections
SFI-700 SERIES
Tube Style with Threaded Connections
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Window: Tempered glass; Body: Bronze or 316 SS; Gasket:
Buna-N, fluoroelastomer or PTFE; Indicator: ABS or 316 SS impeller (100 and
300), 304 SS or 316 SS flapper (360).
Temperature Limit: 200°F (93°C).
Pressure Limit: 125 psig (8.62 bar), 150 psig (10.34 bar) on “MP” models.
Connections: Threaded.
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Tube: Tempered borosilicate; Body: Brass or 316 SS; Gasket:
Fluoroelastomer; Indicator: Acetal.
Temperature Limit: 212°F (100°C).
Pressure Limit: 230 psig (15.86 bar).
Connections: Threaded.
Example
SFI 300 SS
2
G2
Model
SFI
Designator
Body
100
Style
300
350
360
Body
SS
Options
MP
Body
Size
Options
W2
G1
G2
S2
S3
I1
I2
I3
F1
BSPT
BSPP
Example
SFI
Model
Designator
SFI
700SS 1-1/2
700
700SS
Body
Style
Body
Size
1/4
3/8
1/2
3/4
1
1-1/4
1-1/2
Options
SFI-700SS-1-1/2 Sight Flow Indicator; tube type with 8
blade Acetal impeller and integral wipers to clean tube
interior, tempered borosilicate tube, Fluoroelastomer
gaskets, 316SS body, 1-1/2 inch female NPT
connections
Sight flow indicator, tube type with 8 blade Acetal
impeller and integral wipers to clean tube interior,
tempered borosilicate tube, Fluoroelastomer gaskets
Brass body
316SS body
1/4 inch female NPT connection size
3/8 inch female NPT connection size
1/2 inch female NPT connection size
3/4 inch female NPT connection size
1 inch female NPT connection size
1-1/4 inch female NPT connection size
1-1/2 inch female NPT connection size
BSPT BSPT threads
BSPP BSPP threads
FLOW
1/4
3/8
1/2
3/4
1
1-1/4
1-1/2
2
SFI-300SS-2-G2 Sight Flow Indicator; double window,
temper glass, Fluoroelastomer gaskets, 316SS body,
ABS impeller, 2 inch female NPT connections.
Sight flow indicator, tempered glass standard, Buna-N
gaskets standard, female NPT connections standard.
Single window, bronze body, ABS Impeller
Double window, bronze body, ABS Impeller
Double window, bronze body, no moving indicator
Double window, bronze body, 304SS flapper
316SS body option for 300, 350, 360
150 psig maximum pressure option, includes
Fluoroelastomer gaskets
1/4 inch connection size
3/8 inch connection size
1/2 inch connection size
3/4 inch connection size
1 inch connection size
1-1/4 inch connection size
1-1/2 inch connection size
2 inch connection size
Plexiglass window
PTFE gasket
Fluoroelastomer gasket
316SS Shaft (Not on 350 Model)
Monel Shaft (Not on 350 Model)
ABS impeller with bronze bushing (Not on 350, 360)
316SS impeller (Not on 350, 360)
No impeller (100 only)
316SS Flapper (360 only)
BSPT threads
BSPP threads
(Maximum flow on impeller models: 5 FPS with liquids, 5000 FPM with gases)
SFI-400 SERIES
Tube Style with Threaded or Flanged Connections
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Window: Tempered glass; Body: Carbon steel or 316 SS;
Gasket: Buna-N, fluoroelastomer or PTFE; Indicator: 316 SS flapper (360).
Temperature Limit: 200°F (93°C).
Pressure Limit: 150 psig (10.34 bar).
Connections: Flanged.
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Tube: Borosilicate; Body: Cast iron or 316 SS; Gasket: PTFE.
Temperature Limit: 200°F (93°C).
Pressure Limit: 50 psig (3.45 bar).
Connections: Threaded or flanged.
Example
Model
Designator
Body
Style
Body
Size
Options
SFI 360FSS 1-1/2 G1 SFI-360FSS-1-1/2-G1 Sight Flow Indicator; double
window, tempered glass, PTFE gasket, 316SS body,
304SS flapper, 1-1/2 inch raised face flange connections
Sight flow indicator, double window, tempered glass,
SFI
Buna-N gaskets standard, raised face flange connections
Carbon steel body, no moving indicator
350FCS
316SS body, no moving 316SS indicator
350FSS
Carbon steel body, 316SS flapper
360FCS
316SS body, 316SS flapper
360FSS
1-1/2 inch raised face flange connection size
1-1/2
2 inch raised face flange connection size
2
3 inch raised face flange connection size
3
4 inch raised face flange connection size
4
6 inch raised face flange connection size
6
G1 PTFE gasket
G2 Fluoroelastomer gasket
Example
SFI
Model
SFI
Designator
Body
Style
400
1-1/2
400CI
400SS
400F
Body
Size
1/2
3/4
1
1-1/4
1-1/2
2
3
4
SFI-400SS-1-1/2 Sight Flow Indicator; tube type,
borosilicate tube, PTFE gaskets, 316SS body, 1-1/2
inch female NPT connections
Sight flow indicator, tube type, borosilicate tube,
PTFE gaskets
Female NPT connections, cast iron body (only for 1
through 2 inch sizes)
Female NPT connections, 316SS body
Raised face flange connection, 316SS body (only for
1 inch and up sizes)
1/2 inch connection size
3/4 inch connection size
1 inch connection size
1-1/4 inch connection size
1-1/2 inch connection size
2 inch connection size
3 inch connection size
4 inch connection size
(Best for use in vertical pipelines where there are no mechanical strains)
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
197
Sight Flow Indicators
SFI-300F SERIES
Window Style with Flanged Connections
198:Layout 2
7/13/11
11:07 AM
Page 1
Series
500
Sight Window
Shows Level or Contents of Tanks, Pipelines; Tempered, Replaceable Glass Window
A NPT
Dimensions — Inches (mm)
Model
A
SFI-500-3/4 3/4
SFI-500-1
1
SFI-500-1-1/4 1-1/4
SFI-500-1-1/2 1-1/2
SFI-500-2
2
ØB
D
C HEX
E
FLOW
Tough, tempered glass window resists chemical attack and abrasion.
Seamless gasket assures perfect seal and is easily field replaceable. In addition
to the standard brass body, Model 500 Sight Windows are also available in
carbon steel or 316 SS to suit a wide range of chemical compatibility.
Model
316 SS
SFI-500SS-3/4
SFI-500SS-1
SFI-500SS-1-1/4
SFI-500SS-1-1/2
SFI-500SS-2
Model
Brass
SFI-500B-3/4
SFI-500B-1
SFI-500B-1-1/4
SFI-500B-1-1/2
SFI-500B-2
Sight Flow Indicators
Series
550
D
E
C
B
1-3/8 (35) 45/64 (18) 1-3/8 (35)
3/4 (19)
15/16 (24) 1-3/8 (35) 45/64 (18) 1-3/8 (35)
1-1/4 (32) 2-1/8 (54) 27/32 (22) 1-9/16 (40)
1-27/64 (37) 2-1/8 (54) 27/32 (22) 1-9/16 (40)
1-1/4 (32) 2-1/2 (64) 15/32 (12) 1-21/32(42)
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials:
Window: Tempered glass;
Body: Brass, carbon steel, or 316 SS;
Gasket: Buna-N on brass and carbon steel body, PTFE on 316 SS
body.
Temperature Limit: 200°F (93°C).
Pressure Limit: 125 psig (8.6 bar).
Connections: 3/4˝ to 2˝ male NPT.
Model
Carbon Steel
SFI-500CS-3/4
SFI-500CS-1
SFI-500CS-1-1/4
SFI-500CS-1-1/2
SFI-500CS-2
APPLICATIONS
• Hydraulic tanks
• Pressure vessels
• Coolant tanks
• Hydraulic lines
• Oil reservoirs
Sight Window
Shows Level or Contents of Tanks, Pipelines; Fused Glass and Steel Construction
Model
SFI-550-1/4
SFI-550-3/8
SFI-550-1/2
SFI-550-3/4
SFI-550-1
SFI-550-1-1/4
SFI-550-1-1/2
SFI-550-2
Fused glass style sight windows feature glass to metal bond for utmost
reliability. Plated steel bodies have convenient hex wrench surfaces.
Connections are standard NPT in sizes from 1/4˝ to 2˝. Windows are clear,
ripple free, and flush with the front face, having no recess on which dirt might
collect.
Model
SFI-550-1/4
SFI-550-3/8
SFI-550-1/2
SFI-550-3/4
198
Dimensions — Inches (mm)
D
C
B
3/16 (4.76)
5/8 (15.95)
11/32 (8.73)
7/32 (5.56)
7/16 (11.11) 3/4 (19.05)
9/16 (14.29) 15/16 (23.81) 7/32 (5.56)
1-1/16 (26.99) 5/16 (7.94)
3/4 (19.05)
15/16 (23.81) 1-3/8 (34.93) 5/16 (7.94)
1-3/16 (30.18) 1-3/4 (44.45) 13/32 (10.32)
13/32 (10.32)
1-7/16 (36.53) 2 (50.80)
1-7/8 (47.63) 2-1/2 (63.50) 13/32 (10.32)
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials:
Window: Glass;
Body: Plated steel.
Temperature Limit: 200°F (93°C).
Pressure Limit: 125 psig (8.6 bar).
Connections: 1/4˝ to 2˝ male NPT.
Model
SFI-550-1
SFI-550-1-1/4
SFI-550-1-1/2
SFI-550-2
VISIT OUR WEBSITES:
A
1/4
3/8
1/2
3/4
1
1-1/4
1-1/2
2
APPLICATIONS
• Hydraulic tanks
• Pressure vessels
• Coolant tanks
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
• Hydraulic lines
• Oil reservoirs
•
www.dwyer-inst.com.au
E
5/8 (15.95)
23/32 (18.26)
25/32 (19.84)
15/16 (23.81)
1-1/16 (26.99)
1-7/32 (30.96)
1-7/32 (30.96)
1-9/32 (32.54)
199:Layout 2
7/13/11
11:07 AM
Page 1
Series
HFO
In-Line Flow Alarms
Latching Alarm Capabilities, For Air, Water or Caustic Fluids, Unrestricted Mounting
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Body: Aluminum, brass or 304 SS;
Seals: Buna-N or fluoroelastomer;
Magnet: PTFE coated Alnico;
Other internal parts: 304 SS.
Viscosity: 500 SSU.
Temperature Limits: 240˚F (116˚C).
Pressure Limits: See chart.
Enclosure Rating: NEMA 4X (IP65).
Accuracy: Measuring ±4% FS over entire range; ±2.5% over center
third of the measuring range.
Repeatability: ±1% of full scale.
Switch Type: SPDT, 10A @ 250 VAC; 0.5A @ 125 VDC, (resistive).
Shipping Weight: 1/4 to 1/2˝ female NPT models: 3 lb (1.4 kg); 3/4 to 1˝
female NPT models: 4.5 lb (2.0 kg); 1-1/2˝ female NPT models: 12 lb
(5.4 kg).
7-1/8
[180.98]
2-15/16
[74.61]
4-1/2
[114.3]
Aluminum body for air or other non-corrosive gases:
600 psig (41 bar)
Wetted Parts: Aluminum, PTFE coated Alnico, 304 SS and Buna-N
APPLICATIONS
Monitoring flow in chemical processing, waste water processing,
lubrication systems, process control, solar systems, drain lines and pump
testing.
Brass body for water based fluids (non-steam):
3500 psig (240 bar)
Wetted Parts: Brass, PTFE coated Alnico, 304 SS and Buna-N
Range, Air SCFM
1.5-12
4-23
Model
Connection Size
HFO-21112 1/4˝ female NPT
HFO-21123 1/4˝ female NPT
Flowmeters with Switch
Model
HFO-22205
HFO-22315
HFO-22320
HFO-22440
HFO-22550
FLOW
The Series HFO Flow Alarm provides continuous monitoring and control of
flow rate levels. The flow alarm can be configured to open or close a contact for
an increasing or decreasing set point. The unit includes two 10A SPDT limit
switches with field adjustable alarm settings. Integral direct reading scale
provides local indication of flow rate. The flow alarm is designed to mount in any
orientation and does not require inlet or outlet straight plumbing. The Series
HFO is constructed with a rugged cast aluminum NEMA 4X (IP65) enclosure
for installations outdoors or in harsh environments.
Range, Water
GPM (LPM)
0.5-5.0 (1-19)
1-15 (3.8-55)
2-20 (7.5-75)
4-40 (15-151)
5-50 (19-189)
Connection Size
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
1˝ female NPT
1-1/2˝ female NPT
304 SS body for high-pressure fluids:
6000 psig (413 bar)
Wetted Parts: 304 SS, Fluoroelastomer and PTFE
Range, Water
GPM (LPM)
Model
Connection Size
0.2-2.0 (0.75-7.5)
HFO-23202 1/2˝ female NPT
1-10 (3.8-38)
HFO-23210 1/2˝ female NPT
Pressure Differential VS. Flow Rate
HFO-22320
HFO-21123
1.5
1.0
HFO-21112
0.5
0
0
10 15 20 25
5
Flow Rate: SCFM @ 100 PSIG
CALL TO ORDER:
U.S. Phone 219 879-8000
10
HFO-23210
8
6
4
HFO-22205
2
HFO-23202
0
0
•
Pressure Differential PSID
2.0
3/4˝, 1˝ & 1-1/2˝ Female NPT
1/2˝ Female NPT
Pressure Differential PSID
Pressure Differential PSID
1/4˝ Female NPT
2
4
6
8
Flow Rate: GPM
10
HF0-22440
8
6
4
HFO-22550
2
0
0
10
U.K. Phone (+44) (0)1494-461707
HFO-22315
12
•
10 20 30 40 50
Flow Rate: GPM
Australia Phone (+61) (0) 2 4272 2055
199
200:Layout 2
7/13/11
11:08 AM
Page 1
Series
V4
Vane
Operated
Flow
Switch
Field Adjustable – Dependable Protection Against Flow
Certified Product
Variation or Stopping in Pipelines for Fluids, Gases and
Flowing Solids
Australian
Standard
3-11/32
[84.93]
1-5/8 [41.28]
CLEARANCE FOR
COVER REMOVAL
UL AND CSA TYPE
INCLUDES 16 GA LEADS,
6 [152.4] LONG.
ATEX VERSION INCLUDES
TERMINAL BLOCK
6-3/4
[171.45]
8
[203.20]
EXPLOSION-PROOF HOUSING
WITH 3/4 FEMALE NPT
CONDUIT CONNECTION
SWITCH BODY, SAE 72 BRASS
OR 316 STAINLESS STEEL
1-1/2 MALE NPT
PROCESS CONNECTION
MAGNET KEEPER,
430 STAINLESS STEEL
VANE BLOCK,
316 STAINLESS STEEL
4-11/16
[119.06]
1
[25.40]
FLOW
FIVE LAYER VANE 316
STAINLESS STEEL DESIGNED
FOR 1-1/2˝ TO 8˝ PIPES
USABLE IN LARGER PIPE
SIZES.
Rugged and reliable the Series V4 Flotect® flow switch operates automatically to
protect equipment and pipeline systems against damage from reduction or loss of flow.
The V4 is time tested being installed in thousands of pipelines and processing plants around
the world. A unique magnetically actuated switching design gives superior performance.
There are no bellows, springs, or seals to fail. Instead, a free-swinging vane attracts a
magnet within the solid metal switch body, actuating a snap switch by means of a simple
lever arm.
Flow Switches, Paddle
2-23/32
[69.06]
SPECIFICATIONS
Service: Gases or liquids compatible
with wetted materials.
Wetted Materials:
Vane: 316 SS;
Body: Brass or 316 SS standard;
Magnet Keeper: 430 SS standard,
316 SS optional;
Options: Other materials also
available, consult factory (e.g. PVC,
Hastelloy, nickel, Monel, titanium).
Temperature Limit: -4 to 275°F (-20 to
135°C) standard, MT high temperature
option 400°F (205°C) [MT option not
UL, CSA, ATEX, or SAA].
Pressure Limit: Brass body 1000 psig
(69 bar), 316 SS body 2000 psig (138
bar), optional 5000 psig (345 bar)
available with 316 SS body and SPDT
switch only.
Enclosure Rating: Weatherproof
(meets NEMA 4 (IP65)) and explosionproof. Listed with UL and CSA for
Class I, Groups C and D; Class II,
Groups E, F, and G. ATEX
0344
II 2 G EEx d IIB T6 -20°C≤Tamb≤75°C;
EC-Type Certificate No.: KEMA
03ATEX 2383; SAA: Exd II C T6 (T
amb=60°C). Zone I. Also FM approved.
FEATURES
• Leak proof body machined from bar stock
• Choice of custom vane calibrated for your application, Model V4, or field adjustable
multilayer vane, Model V4-2-U (see set point chart)
• Weatherproof, designed to meet NEMA 4
• Explosion-proof (listing included in specifications)
• Installs directly and easily into pipeline with a thredolet, tee, or flange (see
application drawings)
• Can be used in pipes 1-1/2˝ and up
• Electrical assembly can be easily replaced without removing the unit from
installation so that the process does not have to be shut down
• High pressure rating of 1000 psig (69 bar) with the brass body and 2000 psig
(138 bar) with the 316 SS body
APPLICATIONS
• Protects pumps, motors and other equipment against low or no flow
• Controls sequential operation of pumps
• Automatically starts auxiliary pumps and engines
• Stops liquid cooled engines, machines and processing when coolant flow is
interrupted
• Shuts down burner when air flow through heating coil fails
• Controls dampers according to flow
Model
Description
V4-2-U
Brass body, universal vane
V4-SS-2-U
316SS* body, universal vane
V4
Brass body, custom vane
V4-SS
316SS* body, custom vane
*316SS body with 430SS magnet keeper.
OPTIONS (add as a suffix to the model number):
-D, DPDT contacts
-MV, Gold Plated Contacts, options for dry circuits
(see electrical rating in specification, no listings or approvals)
-MT, High Temperature, option rated 400°F (204°C)
(see electrical rating in specifications, no listings or approvals)
-TRI (increasing flow), -TRD (decreasing flow), Time Delay Relay,
option with 2 SPDT contacts, adjustable from 0-1 to 0-31 minutes.
(no listings or approvals)
-316, 316 SS Magnet Keeper, option to replace standard 430 SS
-SAA, SAA listed construction
-V, Vertical Up Flow, option for upward flow in vertical pipe
-AT, ATEX listed construction
Consult factory for price and availability of fittings for V4 installation. Thredolets,
bushings, and tees are available in a variety of sizes and materials.
For custom vane models, please supply factory with following information: pipe size,
flow direction (horizontal, up), mounting, pressure, temperature, specific gravity, flow
rates (maximum normal, actuation/deactuation*), etc.
*When both values are supplied, note which is critical.
200
VISIT OUR WEBSITES:
www.dwyer-inst.com
Switch Type: SPDT snap switch
standard, DPDT snap switch optional.
Electrical Rating: UL, FM, ATEX and
SAA models 10A @ 125/250 VAC (V~).
CSA models: 5A @ 125/250 VAC (V~);
5A res., 3A ind. @ 30 VDC (V ). MV
option: 1A @125 VAC (V~); 1A res.,
.5A ind. @ 30 VDC (V ). MT option:
5A @ 125/250 VAC (V~). [MT and MV
option not UL, CSA, FM, ATEX or
SAA].
Electrical Connections: UL and CSA
models: 16 AWG, 6˝ (152 mm) long.
ATEX and SAA unit: Terminal block.
Conduit Connection: 3/4˝ female
NPT.
Process Connection: 1-1/2˝ male
NPT.
Mounting Orientation: Within 5° of
vertical for proper operation. Units for
horizontal installation (vertical pipe with
up flow) available.
Set Point Adjustment: For universal
vane: five vane combinations.
Weight: 4 lb 8 oz (1.9 kg).
Agency Approvals: UL, CSA, CE, FM,
SAA, and ATEX.
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
201:Layout 2
7/13/11
1:20 PM
Page 1
V4 Universal Vane Flow Charts
Values shown in both charts are nominal. If normal flows exceed actuation rates by less than 10%, custom vanes are recommended.
Figures are based on standard vertical installation in a 1-1/2" Threaded Branch Connection in a horizontal run of pipe.
Approximate Actuation/Deactuation Flow Rates for Cold Water.
Upper Figures in GPM. Lower Figures in LPM.
Vane
Layers
1
1.5˝ Pipe
2˝ Pipe
7-3
15-8
26.67-11.67 56.7-30
7-4
26.7-15
1&2
1,2,&3
3˝ Pipe
45-22
167-83.3
23-14
86.7-53.3
11-7
41.7-26.7
1,2,3,&4
4˝ Pipe
95-40
367-150
50-35
190-132
27-19
102-71.7
17-12
65-45
1,2,3,4,&5
6˝ Pipe
210-120
800-450
130-90
500-333
80-60
300-233
60-45
233-167
40-30
152-113
8˝ Pipe
375-175
1417-667
230-150
867-567
160-115
600-433
120-90
450-333
80-65
300-250
10˝ Pipe
600-300
2267-1133
450-250
1700-950
300-180
1133-683
230-150
867-567
135-100
517-383
12˝ Pipe
900-450
3400-1700
650-350
2467-1317
450-275
1700-1033
310-200
1167-750
200-140
750-533
14˝ Pipe
1200-600
4550-2267
900-500
3400-1900
600-350
2267-1317
430-280
1633-1067
290-200
1100-750
16˝ Pipe
1400-800
5300-3033
1200-650
4550-2467
750-450
2750-2083
550-360
2083-1367
360-250
1367-950
18˝ Pipe
2000-1000
7567-3783
1450-800
5483-3033
1000-600
3783-2267
700-450
2650-1700
460-325
1733-1233
20˝ Pipe
2400-1200
9083-4550
1800-1000
6817-3783
1200-700
4550-2650
850-550
3217-2083
575-400
2183-1517
Actuation rates are based on cold water at a specific gravity of 1.0.
For fluids of different specific gravity, actuation rates may be approximated by dividing the rate shown by the square root of the specific gravity.
Approximate Actuation/Deactuation Flow Rates for Cold Air.
Upper Figures in SCFM. Lower Figures in LPS.
Vane
Layers
1
1.5˝ Pipe 2˝ Pipe
32-17
65-32
15-8
30-20
23-13
10-6
1&2
1,2,&3
1,2,3,4,&5
4˝ Pipe
400-200
190-90
195-140
90-70
135-100
60-50
65-50
30-20
6˝ Pipe
950-475
450-220
550-375
260-180
375-265
180-130
260-200
120-90
130-100
60-50
8˝ Pipe
1550-850
730-400
1100-700
520-330
725-500
340-240
500-400
240-190
310-250
150-120
10˝ Pipe
2400-1300
1100-600
1850-1200
870-570
1200-850
570-400
875-700
410-330
650-525
310-250
12˝ Pipe
3450-1900
1600-900
2700-1750
1300-800
1850-1300
870-610
1250-1000
590-470
1000-800
470-380
14˝ Pipe
4700-2600
2200-1200
3400-2200
1600-1000
2600-1800
1200-800
1900-1500
900-710
1600-1250
760-590
16˝ Pipe
6400-3500
3000-1700
4800-3100
2300-1500
3350-2350
1600-1100
2500-2000
1200-900
2200-1750
1040-830
18˝ Pipe
8000-4400
3800-2100
6000-3900
2800-1800
4300-3000
2000-1400
3100-2500
1500-1200
2800-2250
1300-1100
20˝ Pipe
10000-5500
4700-2600
7400-4800
3500-2300
5300-3700
2500-1700
3900-3100
1800-1500
3550-2850
1700-1300
FLOW
1,2,3,&4
3˝ Pipe
210-105
100-50
120-70
60-30
60-48
30-20
Actuation rates are based on air at standard conditions. For gases at other pressures, temperatures, or specific gravities, consult factory for
equivalent flow approximations.
Application Drawings
For Flotect® Automatic Flow Switches
REQUIRED FLOW HOLDS
SWITCH OPEN WHEN FLOW
SLOWS, VANE DROPS,
ACTUATION SWITCH
3/4˝ NPT FOR CONDUIT
ALUMINUM ENCLOSURE
FOR ELECTRICAL
CONNECTIONS
1-1/2 THREADED BRANCH
CONNECTION
CUT 1-15/16 MIN.
HOLE IN PIPE
SWITCH BODY MACHINED
FROM BAR OF BRASS OR
STAINLESS STEEL
2 1/2˝
THREADED
BRANCH
CONNECTION
CUT HOLE
IN PIPE
1 15/16˝ (49.2)
DIA. MINIMUM
1-1/2˝ x 1-1/2˝
x 1-1/2˝
Tee Installation
Standard
Installation
2 1/2 x 1 1/2˝
FACE OR HEX
BRUSHING
Flow Switches, Paddle
THREADED COVER IS
EASILY REMOVED FOR
ACCESS TO SWITCH
1 1/2
THREADED
BRANCH
CONNECTION
CUT HOLE IN
PIPE 2 7/8˝
(73.0) DIA.
MINIMUM
2-1/2˝ Threaded
Branch
Connection
3/4˝ N.P.T.
FLOW
3/4˝ N.P.T.
1 1/2˝ 3000 L.B.
COUPLING
ANSI RF
THREADED
REDUCING
FLANGE
1˝ (25.4)
2 1/16
(52.4)
BORE I.D.
Threaded Branch Connection Installation.
May also be installed using tee, flange or coupling.
“A”
ANSI RF
WELDING
NECK
FLANGE
•FLANGE FACE TO PIPE
O.D. SPECIFIED CUSTOMER.
NORMALLY SHOULD NOT EXCEED 5˝ (172).
2˝ x 2˝ x 2˝
Tee
Installation
Flange
Installation
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Not Recommended,
Unless Coupling is
Bored Out to 2-1/16˝
(52.4) As Shown
Australia Phone (+61) (0) 2 4272 2055
201
202:Layout 2
7/13/11
1:31 PM
Page 1
Mini-Size Flow Switches
Series
V6
Monitor flow in 1/2˝ to 2˝ pipe, Explosion-proof
V6 with 1/2˝ Tee
LOCKING COLLAR
ASSEMBLY
3/4 NPT
UPPER HOUSING
SWITCH SUPPORTS
SPDT (OR DPDT)
SNAP SWITCH
MAGNET LEVER PIN
V6 Low Flow
18 GA. LEADS
18 [457.20] LONG
MAGNET LEVER
ASSEMBLY
6-5/16
[160.34]
MAGNETS
SWITCH HOUSING
300 SERIES STAINLESS
STEEL OR BRASS
3-3/8
[85.73]
4-3/4
[120.65] SWITCH BODY
1-1/8 [28.58] SQ
300 SERIES STAINLESS
STEEL OR BRASS
LOWER HOUSING-BRASS
OR STAINLESS STEEL
CERAMIC MAGNET
VANE SPRING
PISTON 300
VANE PIVOT PIN
SERIES STAINLESS
VANE PIVOT
STEEL OR BRASS
BRACKET
1/2 NPT SNAP RING
INLET 1/2 NPT
STAINLESS
STEEL VANE
FLOW
Flow Switches, Paddle
3/4 NPT
OVERALL LENGTH WITH
1-1/4˝ TEE CONNECTION
APPROXIMATELY 8˝
VALVE BODY MATERIAL
300 SERIES STAINLESS
STEEL OR BRASS
FEATURES
• Leak proof lower body machined from bar stock
• Choice of models in a tee with calibrated vane or field adjustable trimmable vane
• Weatherproof
• Explosion-proof (listing included in specifications)
• Electrical assembly can be easily replaced without removing the unit from the
installation so that the process does not have to be shut down
• High pressure rating of 1000 psig (69 bar) with brass body and 2000 psig (138
bar) on the 316 SS body (see specifications)
• Low flow model offers field adjustable set point
• Easy installation, simply insert the tee in the pipline and complete electrical
connections
APPLICATIONS
• Protects pumps, motors and other equipment against low or no flow
• Controls sequential operation of pumps
• Automatically starts auxillary pumps and engines
• Shuts down burner when air flow through heating coil fails
• Controls dampers according to flow
VISIT OUR WEBSITES:
www.dwyer-inst.com
3-5/8
[92.08]
O-RING
BUNA-N
HARDWARE (SCREW, SPRINGS & CHECK
VALVE) STAINLESS STEEL
SPECIFICATIONS
Service: Gases or liquids compatible with wetted materials.
Wetted Materials: Standard V6 models: Vane: 301 SS; Lower Body: Brass or 303
SS; Magnet: Ceramic; Other: 301, 302 SS; Tee: Brass, iron, forged steel, or 304 SS.
V6 low flow models: Lower body: Brass or 303 SS; Tee: Brass or 304 SS; Magnet:
Ceramic; O-ring: Buna-N standard, fluoroelastomer optional; Other: 301, 302 SS.
Temperature Limits: -4 to 220°F (-20 to 105°C) standard, MT high temperature
option 400°F (205°C) (MT not UL, CSA or ATEX). ATEX compliant AT option ambient
temperature -4 to 167°F (-20 to 75°C), process temperature: -4 to 220°F (-20 to
105°C).
Pressure Limit: Brass lower body with no tee models: 1000 psi (69 bar); 303 SS
lower body with no tee models: 2000 psi (138 bar); Brass tee models: 250 psi (17.2
bar); Iron tee models: 1000 psi (69 bar); Forged and stainless steel tee models: 2000
psi (138 bar); Low flow models: 1450 psi (100 bar).
Enclosure Rating: Weatherproof and explosion-proof. Listed with UL and CSA for
Class I, Groups A, B, C and D; Class II, Groups E, F, and G. (Group A on stainless
steel body models only).
ATEX
0344 II 2 G EEx d IIC T6 Process Temp≤75°C.
EC-type Certificate No.: KEMA 04ATEX2128.
Switch Type: SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating: UL models: 5A @125/250 VAC (V~). CSA and ATEX models: 5A
@ 125/250 VAC (V~); 5A res., 3A ind. @ 30 VDC (V ). MV option: .1A @ 125 VAC
(V~). MT option: 5A @125/250 VAC (V~). [MT option not UL, CSA or ATEX].
Electrical Connections: UL models: 18 AWG, 18˝ (460 mm) long; ATEX and CSA
models: terminal block.
Upper Body: Brass or 303 SS.
Conduit Connections: 3/4˝ male NPT standard, 3/4˝ female NPT on junction box
models.
Process Connection: 1/2˝ male NPT on models without a tee.
Mounting Orientation: Switch can be installed in any position but the
actuation/deactuation flow rates in the charts are based on horizontal pipe runs and
are nominal values.
Set Point Adjustment: Standard V6 models none. Without tee models vane is
trimmable. Low flow models are field adjustable in the range shown. See set point
charts on opposite page.
Weight: 2 to 6 lb (.9 to 2.7 kg) depending on construction.
Options not Shown: Custom calibration, bushings, PVC tee, reinforced vane.
Agency Approvals: UL, CSA, CE, and ATEX.
Surprisingly compact, the Series V6 Flotect® Flow Switch is engineered to
specifically monitor liquid, gas, or airflows. Operation is simple and dependable with no
mechanical linkage as the flow switch is magnetically actuated. The lower body holds the
flow vane and one magnet, which controls the switch actuating magnet in the separate
upper housing. In most applications the switch is normally off with the pipeline flow forcing
the vane against the vane spring. As the flow decreases the vane spring pushes back the
vane, actuating the switch to signal an alarm or shutdown. Tees are available for installation
in pipelines from 1/2˝ to 2˝, with bushings added the unit is easily adapted to 1/4˝ and 3/8˝
piping.
202
OUTLET 1/2 NPT
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
203:Layout 2
7/13/11
1:32 PM
Page 1
V6EPB-B-S-2-B-MT flow switch; brass upper housing, brass lower housing, brass tee with 3/4˝ NPT
connections, SPDT snap switch, and high temperature option
Series
Series V6 flow switch
V6
Construction
Explosion proof
EP
Upper
Brass
B
Body
Stainless Steel
S
Lower
Brass
B
Body
Stainless Steel
S
Circuit
SPDT
S
(Switch)
DPDT
D
1/2˝ NPT
Tee Connection
1
3/4˝ NPT
Size
2
1˝ NPT
3
1-1/4˝ NPT
4
1-1/2˝ NPT
5
2˝ NPT
6
Low Flow Model (1/2˝ NPT connections)
LF
Tee
Iron
MI
Material
Forged Steel
FS
Brass
B
Stainless Steel
S
No tee, field trimmable vane
0
(For LF Model no tee material chosen, tee material matches lower housing choice)
Options
CSA CSA approved construction with junction box*
ATEX approved construction with junction box
AT
MV Gold contacts on snap switch for dry circuits (see specifications for ratings)
MT High temperature option rated 400°F (205°C) (see specifications for ratings)*
VIT Fluoroelastomer O-rings in place of Buna-N on low flow models
Example
V6 EP B B S 2
B
MT
*Options that do not have ATEX.
FLOW
V6 Set Point Charts - Factory Installed Tee
Approximate ActuationDeacuation Flow Rates for Air.
Upper figures are SCFM,
Lower figures in LPM
Pipe
Size
1/2˝
3/4˝
1-1/4˝
1-1/2˝
2
Deactuate
6.50
180
10.0
300
14.0
420
21.0
600
33.0
960
43.0
1200
5.00
120
8.00
240
12.0
360
18.0
540
30.0
840
36.0
1020
V6 Low Flow Set Point Chart
Min-Max Flow Rates in 1/2˝ Pipe
Media
GPM-Water
LPM-Water
SCFM-Air
LPS-Air
Actuate
.04-0.75
.15-2.84
.18-2.70
.09-1.3
Deactuate
.03-0.60
.11-2.27
.15-2.0
.07-.95
Pressure drop (head loss) is a function of both set point and flow rate. Typically,
pressure drop at actuation flow rate listed will be 5-10 psid (.34-.69 bar). Pressure
drops at other flow rates will vary in proportion to the (change in flow).
CALL TO ORDER:
U.S. Phone 219 879-8000
•
Model
V6EPB-B-S-1-B
V6EPB-B-S-2-B
V6EPB-B-S-3-B
V6EPB-B-S-4-B
V6EPB-B-S-5-B
V6EPB-B-S-6-B
V6EPB-B-S-1-MI
V6EPB-B-S-2-MI
V6EPB-B-S-3-MI
V6EPB-B-S-4-MI
V6EPB-B-S-5-MI
V6EPB-B-S-6-MI
V6EPB-S-S-1-MI
V6EPB-S-S-2-MI
V6EPB-S-S-3-MI
V6EPB-S-S-4-MI
V6EPB-S-S-5-MI
V6EPB-S-S-6-MI
V6EPB-S-S-1-FS
V6EPB-S-S-2-FS
V6EPB-S-S-3-FS
V6EPB-S-S-4-FS
V6EPB-S-S-5-FS
V6EPB-S-S-6-FS
V6EPB-S-S-1-S
V6EPB-S-S-2-S
V6EPB-S-S-3-S
V6EPB-S-S-4-S
V6EPB-S-S-5-S
V6EPB-S-S-6-S
V6EPB-B-S-6-0
V6EPB-S-S-6-0
V6EPB-B-S-LF
V6EPB-S-S-LF
U.K. Phone (+44) (0)1494-461707
Size
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
1/2˝
3/4˝
1˝
1-1/4˝
1-1/2˝
2˝
No Tee
No Tee
1/2˝
1/2˝
•
Lower Body
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Brass
SS
Brass
SS
Tee
Brass
Brass
Brass
Brass
Brass
Brass
Iron
Iron
Iron
Iron
Iron
Iron
Iron
Iron
Iron
Iron
Iron
Iron
FS
FS
FS
FS
FS
FS
SS
SS
SS
SS
SS
SS
None
None
LF, Brass
LF, SS
Australia Phone (+61) (0) 2 4272 2055
Flow Switches, Paddle
1
Actuate
Approximate ActuationDeactuation Flow Rates for Cold
Water.
Upper figures are GPM,
Lower figures in LPM
Pipe
Actuate
Deactuate
Size
1.50
1.00
1/2˝
5.667
3.83
2.00
1.25
3/4˝
7.5
4.67
3.00
1.75
1
11.33
6.67
4.00
3.00
1-1/4˝
15.17
11.3
6.00
5.00
1-1/2˝ 22.67
18.9
10.00
8.50
2
37.83
32.2
203
204:Layout 2
7/20/11
3:07 PM
Page 1
Vane Operated Flow Switch
Series
V7
Magnetic Linkage
1 NPT
NORMALLY CLOSED
Pipe Size
1
1-1/4
1-1/2
2
2X 47/64 3
[18.65] 4
NORMALLY OPEN
COMMON GROUND
11/16
[17.46]
2-37/64
[65.48]
1-3/8 [34.93]
3/4
[19.05]
A
3.702
6-31/32 [177.00]
.554
1/2 FEMALE
NPSM
FLOW
The Series V7 Flotect® Flow Switch is an inexpensive switch for use with compatible
liquids to start or stop electronic operated equipment when flow or no-flow conditions
occur. Magnetic operation is simple and dependable with no mechanical linkages or seals
to wear or leak. Lower body is machined solid metal bar stock assuring no leak points, no
matter how long the unit is in service. Design is standard weatherproof, meeting NEMA
4X, for application versatility. Robust vane design is rigid and field trimmable for set point
adjustment.
SPECIFICATIONS
Service: Liquids compatible with
wetted materials that are non-coating
and non-crystallizing.
Wetted Materials: Vane: 301 SS;
Process connection: Brass or 316 SS;
Magnet: Ceramic; Other: 301, 302 SS.
Upper Body Material: Die cast
aluminum.
Temperature Limits: -40 to 250°F (-40
to 121°C).
Pressure Limits: 250 psi (17.2 bar).
Enclosure Rating: Weatherproof,
meets NEMA 4X (IP66).
Switch Type: SPDT snap switch.
Electrical Rating: 10A @ 125, 250,
480 VAC; 1/8 hp @ 125 VAC, 1/4 hp @
250 VAC.
Approximate Actuation-Deactuation Flow Rates
for Cold Water GPM (LPM)
Deactuate
Actuate
Pipe Size
6.8 (25.7)
7.5 (28.4)
1˝
7.6 (28.9)
8.1 (30.8)
1-1/4˝
10.9 (41.3)
11.7 (44.1)
1-1/2˝
15.6 (59.1)
16.9 (64.0)
2˝
18.1 (68.5)
19.6 (74.2)
2-1/2˝
29.6 (112)
31.6 (120)
3˝
52.0 (197)
58.0 (218)
4˝
Contact the factory for different actuation-deactuation rates.
Model
V7-WBS-30N
V7-WSS-30N
DIM A
1-17/64 [32.15]
1-19/32 [40.48]
1-53/64 [46.43]
2-11/64 [55.17]
2-11/64 [55.17]
2-11/64 [55.17]
Electrical Connections: 3 screw type,
common, normally open and normally
closed.
Conduit Connection: 1/2˝ NPSM.
Process Connection: 1˝ male NPT.
Contact factory for optional tees.
Pipe Size: 1 to 4 inch.
Mounting Orientation: Horizontal or
vertical (actuation flow rates are based
on horizontal pipe runs in the vertical
position). Will not work in vertical pipe
with down flow.
Set Point Adjustment: Vane is
trimmable, see set point chart.
Weight: 1 lb 2 oz (500 g).
Agency Approvals: CE, UL353.
Body Material
Brass
316 SS
Mini-Size Flow Switch
Series
V10
Flow Switches, Paddle
Proof of Flow or No Flow in 1/2 to 2” Pipe,
Low Cost, Leak Proof Body, Weatherproof
4 [101.6]
18 AWG LEADWIRES
19˝ [482.6] LONG
1 [25.40]
1/4 [6.35] TRAVEL
TO NORMALLY
CLOSED POSITION
2-7/8
[73.07]
2-7/8 [73.07]
LOWER BODY
7/8 HEX
1/2 MALE NPT
VANE
2-3/8
[61.11]
NORMALLY CLOSED POSITION
NORMALLY OPEN POSITION
Designed to provide an inexpensive, reliable unit to monitor the presence or
absence of flow in a system. The V10 flow switch is used to monitor unattended equipment
and protect it from costly damage. The V10 flow switch utilizes a rugged, hermetically
sealed reed switch which is encapsulated in a polypropylene switch housing that fits into a
standard heavy duty leak proof brass body or optional 303 SS body. The switch adjustment
allows the user to change the switch to Normally Open (NO) or Normally Closed (NC) in the
field merely by loosening two screws. The switch housing is located outside the process
media, making switch change-over or maintenance easy without interruption of process
flow.
A full size, trimmable stainless steel vane is provided with a removable laminated template.
This template is calibrated for brass or ductile iron reducing tees and forged steel straight
tee/bushing combinations. Allows for field installation in pipelines from 1/2˝ to 2˝ diameter.
A table with approximate actuation and deactivation values is provided below.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Vane: 301 SS;
Body: Brass or 303 SS;
Pin and spring: 301 SS, 302 SS,
and 316 SS;
Magnet: Ceramic 8.
Temperature Limit: 200°F (93°C).
Pressure Limit: Brass body: 1000 psig
(69 bar); 303 SS body: 2000 psig (138
bar).
Enclosure Rating: Weatherproof,
meets NEMA 4X (IP66).
Switch Type: SPST hermetically
sealed reed switch. Field adjustable for
normally open or normally closed.
Electrical Rating: 0.5A @ 30 VAC;
1.5A @ 24 VDC.
Cold Water Flow Rates
Air Flow Rates
Approximate actuation/deactuation Approximate actuation/deactuation
GPM upper, LPM lower
SCFM upper, LPM lower
Pipe Trim N.O.
N.C.
Pipe
Trim
N.O.
N.C.
1/2˝
L
2.6/2.3
2.6/2.5
1/2˝
L
10.3/8.8
10.2/9.2
9.8/8.7
9.8/9.5
291.7/250
288/260
3/4˝
J
3.1/2.7
3.1/2.8
3/4˝
J
13/11.6
12.9/11.6
11.7/10.2 11.7/10.6
368.3/328
365/328
1˝
H
4.8/4.5
4.8/4.4
1˝
H
19.2/17.6
18.9/17.6
18.2/17
18.2/16.7
543.3/498
535/498
1-1/4˝ E
6.2/5.6
6.1/5.6
1-1/4˝ E
24.8/22.2
24.5/22.5
23.5/21.2 23.1/21.2
701.7/628
693/637
1-1/2˝ C
8.2/7.7
8.2/7.7
1-1/2˝ C
33.4/31.2
33/30.6
31/29.1
31/29.1
946.7/883
935/867
2˝
Full 9.5/9.1
9.5/9
2˝
Full
50.2/48.4
50.2/47.7
36/34.4
36/34.1
1422/1370 1422/1352
204
VISIT OUR WEBSITES:
www.dwyer-inst.com
Model Body Material
V10
Brass
V10SS 303SS
•
www.dwyer-inst.co.uk
Electrical Connections: 18 AWG, 18˝
(460 mm) long, PVC jacket. Rated
221°F (105°C).
Process Connection: 1/2˝ male NPT
standard. Contact factory for other
options.
Mounting Orientation: Switch can be
installed in any position but the
actuation/deactuation flow rates are
based on horizontal pipe runs and are
nominal values.
Set Point Adjustment: Vane is
trimmable.
Weight: 4.5 oz (0.13 kg).
Agency Approvals: CE, UL and CSA.
Switch Enclosure: Polypropylene.
Switch Configuration
Normally Open or Closed
Normally Open or Closed
•
www.dwyer-inst.com.au
205:Layout 2
7/13/11
2:41 PM
Page 1
Series
FS-2
Vane Flow Switch
Low Cost, Field Adjustable Set Point
2-13/32
[61.1]
5
[127]
4-17/64
[108.3]
3-1/32
[77]
5-49/64
[146.5]
x
5-1/8
[130.2]
APPLICATION
• Perfect for proving flow in boilers, hot water heaters, and chillers
Flow Rate Chart
Blade Vane
Pipe
Length
Diameter in (mm)
(inch)
Dim. X
1
1.34 (34)
1-1/4
1.34 (34)
1-1/2
2.24 (57)
2
2.24 (57)
2-1/2
3.46 (88)
3
3.46 (88)
4
3.46 (88)
5
6.57 (167)
6
6.57 (167)
8
6.57 (167)
Approximate Actuation and Deactuation
Flow Rates for Water
Maximum Setting
Minimum Setting
GPM (LPM)
GPM (LPM)
Actuate
Actuate
Deactuate
Deactuate
4.0 (15.0)
8.8 (33.3)
1.8 (6.7)
6.6 (25.0)
5.3 (20.0)
11.4 (43.3)
2.6 (10.0)
8.4 (31.7)
7.0 (26.7)
14.5 (55.0)
4.0 (15.0)
11.4 (43.3)
14.1 (53.3) 9.7 (36.7)
31.3 (118.3) 22.5 (85.0)
18.5 (70.0) 15.4 (58.3)
35.2 (133.3) 30.8 (116.7)
27.7 (105.0) 25.1 (95.0)
52.8 (200.0) 46.2 (175.0)
59.4 (225.0) 52.8 (200.0) 123.3 (466.7) 114.5 (433.3)
52.8 (200.0) 39.6 (150.0) 132.1 (500.0) 123.3 (466.7)
75.7 (286.7) 52.8 (200.0) 154.1 (583.3) 140.9 (533.3)
184.9 (700.0) 158.5 (600.0) 396.3 (1500.0) 374.2 (1416.7)
CALL TO ORDER:
U.S. Phone 219 879-8000
•
Series FS-2, Paddle Flow Switch
OPTIONS
BSPT Process Connection,
To order add suffix -BSPT.
Example: FS-2-BSPT
Conduit Connection, 1˝ NPT female conduit connection with no wire leads.
To order add suffix -CND.
Example: FS-2-CND
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
205
Flow Switches, Paddle
FEATURES
• Field adjustable paddle
• Field adjustable set point
• Weatherproof construction
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials:
Bellow: Tin-bronze;
Vane: Stainless steel;
Body: Forged brass.
Temperature Limit: 230ºF (110ºC).
Pressure Limit: 145 psig (10 bar).
Enclosure Rating: NEMA 4 (IP64).
Switch Type: SPDT snap switch.
Electrical Rating: 10A res, 3A ind @ 250 VAC.
Electrical Connection: Cable gland with attached wire leads or optional conduit
connection.
Process Connection: 1˝ male NPT or BSPT.
Mounting Orientation: Switch must be installed vertically on horizontal pipe runs.
Set Point Adjustment: Four vane combinations and an adjustment screw.
Enclosure: Die-cast aluminum alloy.
Weight: 28.22 oz (0.8 kg).
Agency Approvals: CE.
FLOW
The Series FS-2 Vane Flow Switch offers an economical flow proving solution.
Custom set points tailored for the application are enabled by field adjustable vane layers
and a set point adjustment screw. The FS-2 features an aluminum weatherproof housing
for outdoor installation. Paddles are adjustable to fit 1˝ to 8˝ size pipe. FS-2 is ideal for
use in “flow or no flow” applications in cold and hot water systems. Perfect for proving flow
in boilers, hot water heaters, and chillers.
Shown with conduit
connection option
206:Layout 2
7/13/11
2:47 PM
Page 1
Vane Operated Flow Switch
Series
V8
Field Adjustable – 1 to 6 Inch Pipe, Leak Proof Body
3-1/16
[77.79]
12-11/64
[309.17]
5-1/4
[133.35]
Flow Switches, Paddle
FLOW
V8
1/2 NPTM
1-21/32
[41.31]
1-5/16 OCTAGON
[33.34]
1 NPTM
FIELD TRIMMABLE
VANE
V8-WP2
V8 Flotect® Flow Switch Protects Equipment: Operation is simple and dependable.
In most applications, the switch is normally off while there is sufficient flow of liquid or air.
When flow stops, the vane spring moves the vane, actuating a single pole double throw
switch rated 5A @ 120/250 VAC to start or stop motor, pump, engine, etc. Operate a damper
or valve; shut down a burner or actuate an alarm or signal, protecting unattended
equipment from damage or loss of production.
The V8 Flotect® Flow Switch has a leak proof body and vane constructed of tough durable
polyphenylene sulfide which has excellent chemical resistance. The full size trimmable vane
is provided with molded-in graduations allowing for installation in a 1 inch through 6 inch
pipe. Operating pressures are up to 150 psig (10 bar) and temperatures to 212°F (100°C).
The V8 flow switch can be used in various chemical processes, industrial systems and
similar applications where process conditions are compatible with polyphenylene sulfide,
ceramic 8 and 316SS. The V8 Flotect® flow switch is UL recognized as an industrial motor
controller per UL standard 508, suitable for mounting in a protected environment.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Vane and body: Polyphenylene Sulfide (PPS);
Pin and spring: 316 SS or Inconel®;
Magnet: Ceramic 8.
Temperature Limit: 212°F (100°C).
Pressure Limit: 150 psig (10.34 bar).
Enclosure Rating: General purpose, WP/WP2 option is weatherproof.
Switch Type: SPDT snap switch, MV option: SPDT gold contact snap switch.
Electrical Rating: 5A @ 125/250 VAC, 5A resistive, 3A inductive @ 30 VDC;
MV option: 1A @ 125 VAC, 1A resistive, 0.5A inductive @ 30 VDC.
Electrical Connections: 18 AWG, 18˝ (460 mm) long.
Conduit Connection: 1/2˝ male NPT, 1/2˝ female NPT on WP and WP2.
Process Connection: 1˝ male NPT.
Mounting Orientation: Actuation/deactuation flow rates are based on horizontal
pipe runs and are nominal values. Unit cannot be used with vertical down flow.
Set Point Adjustment: Vane is trimmable.
Weight: 4.5 oz (0.13 kg).
Agency Approvals: CE, UL 508 for US and Canada.
Cold Water Flow Rates
Air Flow Rates
Approximate actuation/deactuation Approximate actuation/deactuation
GPM upper, LPM lower
SCFM upper, LPM lower
Pipe Size
Pipe Size
1˝
1˝
10.8/9.1
39/32.6
40.9/34.6
1105/923
1-1/4˝
1-1/4˝
9.8/8.3
37.5/32.2
37.2/31.4
1062/912
1-1/2˝
1-1/2˝
8.6/6.8
33.4/26.7
32.4/25.7
945/757
2˝
2˝
10.9/8.8
43/36.8
41.2/33.4
1218/1042
3˝
3˝
12.9/8.9
52.7/38.9
48.8/33.5
1493/1100
4˝
4˝
21.1/13.8
87.6/63.6
79.7/52.2
2482/1802
6˝
6˝
45/33
168.6/137.4
170.2/124.7
4775/3890
Series V8, Flow Switch
OPTIONS
Gold Plated Contacts, for dry circuits. Rated 1A @ 125 VAC; 1A resistive, 0.5A
inductive @ 30 VDC. To order add suffix -MV.
Example: V8-MV
Inconel® Alloy Option. Inconel® Alloy replaces standard 316 SS wetted parts.
Wetted parts are Inconel® Alloy, ceramic 8, and Polyphenylene Sulfide. To order add
suffix -INC.
Example: V8-INC
Weatherproof Enclosure. Optional housing is phenylpolioxide and provides
weatherproof protection for electrical wiring.
To order add suffix -WP. (Not UL approved)
Example: V8-WP
Weatherproof Enclosure. Optional housing is aluminum and provides weatherproof
protection for electrical wiring.
To order add suffix -WP2. (Not UL approved)
Example: V8-WP2
APPLICATIONS
Applications are chemical processing, air conditioning, refrigeration, heating systems,
cooling lines, machinery, liquid transfer systems, water treatment, food processing, and
machine tools. Also, other applications compatible with the materials of construction.
Inconel® is a registered trademark of Huntington Alloys Corporation
206
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
207:Layout 2
7/13/11
2:48 PM
Page 1
Series
G9
Globe Flow Switch
Adjustable Set Point, Water or Oil Service, 90° Flow Path
1/2 NPT
3-27/32
[97.63]
3/4 NPT
1-3/8
[34.92] 1-7/16 HEX
[36.51]
1-3/8
[34.92]
The Series G9 Globe Flow Switch provides accurate flow detection in water and oil
with ±1% repeatability. A shuttle by-pass vane inside the housing is controlled externally
using an ordinary flat blade screwdriver, allowing flow settings to be changed without
disassembly. Each switch is constructed of non-corrosive materials and resists shock and
vibration. The Series G9 is suitable for triggering alarms on interlocking shutdown
circuitry when flow rate is incorrect and for protecting bearings, gears, and cooling
systems.
Actuation Set Point
Range GPM (LPM)
0.75 - 4.0 (2.8 - 15.1)
2.0 - 8.0 (7.6 - 30.3)
7.0 - 14.0 (26.5 - 53.0)
Series
GVS
Electrical Connections: 18 AWG, 24˝
(61 cm), polymeric lead wires.
Process Connection: 3/4˝ female
NPT.
Mounting Orientation: Any position.
Set points shown are based on vertical,
lead wires up position.
Required Filtration: 150 microns or
better.
Weight: 1 lb, 11 oz (0.76 kg).
Agency Approvals: CE.
Globe Valve Switch
Flow Switches,
Shuttle/Piston
Adjustable Set Point, Rugged Bronze Construction, Straight Through Flow
1/2 NPT
3
[7.62]
1-25/32 HEX
[45]
1 NPT
3-1/4
[83]
The Series GVS offers accurate flow detection with 1% repeatability and external
adjustability over a broad range of flow settings. The durable construction delivers longlife reliability in either water or oil. Generous flow paths keep pressure drop low. The
GVS are ideal for detection of improper flow rates in high volume lubrication, cooling or
process systems.
Model
GVS-111
GVS-112
GVS-113
Actuation Set Point
Range GPM (LPM)
1.0 - 6.0 (3.8 - 22.7)
5.0 - 15.0 (18.9 - 56.8)
2.0 - 8.0 (7.6 - 30.3)
CALL TO ORDER:
FLOW
Model
G9-21
G9-22
G9-23
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing: Bronze;
Shuttle: Acetal; Spring: 316 SS; O-ring:
Fluoroelastomer; Other: Ceramic.
Temperature Limits: -20 to 180°F (-29
to 82°C).
Pressure Limits: 400 psi (27 bar) @
100°F (37.8°C).
Accuracy: ±10% of set point.
Repeatability: ±1% maximum
deviation.
Switch Type: SPDT.
Electrical Rating: .17A @ 120 VAC,
.08A @ 240 VAC, .13A @ 120 VDC, .06A
@ 240 VDC.
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing: Bronze; Shuttle: TFE; Bonnet: Bronze; Spring:
316SS.; Other: Fluoroelastomer, ceramic.
Temperature Limits: -20 to 200°F (-29 to 93°C).
Pressure Limits: 400 psig (27 bar) @ 100°F (38°C).
Accuracy: ±10%.
Repeatability: 1% maximum deviation.
Switch Type: SPDT.
Electrical Rating: .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240
VDC.
Electrical Connections: 18 AWG, 24˝ (61 cm), polymeric lead wires.
Process Connections: 1˝ female NPT.
Mounting Orientation: Any position. Set points shown are based on horizontal,
lead wires up positional
Required Filtration: 150 microns or better.
Weight: 2 lb, 8 oz (1.16 kg).
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
207
208:Layout 2
7/13/11
2:48 PM
Page 1
Series
P2
Flow Switch
Ideal for Air and Post-Filtered Water Applications, Fixed Set Point, FDA Compliant
1
[25.40] 25/32
[19.84]
4-5/16
[109.54]
The compact Series P2 Flow Switch utilizes a piston-type design for both air and pure
water applications. The switches have preset actuation points from 0.05 to 1.0 GPM for
water and 25 CFH to 5 CFM for air. The piston design incorporates a hermetically sealed
SPST magnetic reed switch. The P2 is comprised of PPE and PS housing and piston and
316 SS spring and stop pin. All wetted parts are FDA compliant. Economical and superior
design make this an excellent switch for pure water equipment, filter life monitoring, heat
exchangers, and cooling applications.
FLOW
Media
Liquids
GPM (LPM)
Gases
CFM (LPM)
@ 5 psi
Model
P2-11
P2-12
P2-13
P2-14
P2-15
P2-16
P2-17
P2-18
SPECIFICATIONS
Service: Compatible liquids or gases.
Wetted Materials: Housing: PPE & PS (polyphenylene ether and polystyrene);
Piston: PPE & PS and epoxy; Spring and stop pin: 316 SS.
Temperature Limits: 0 to 212°F (-18 to 100°C).
Pressure Limits: 150 psig (10.3 bar) @ 70°F (21°C); 50 psig (3.4 bar) @ 212°F
(100°C).
Switch Type: SPST, N.O.
Electrical Rating: .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240
VDC.
Electrical Connection: 22 AWG, 18˝ (45.7 cm), PVC lead wires.
Process Connection: 1/4˝ male NPT.
Mounting Orientation: Any position. Set points shown are based on vertical, inlet
down position.
Required Filtration: 50 microns or better.
Weight: 2 oz (.06 kg).
Agency Approvals: CE.
Actuation Set Point
.05 (.19)
.25 (.95)
.50 (1.89)
1.0 (3.79)
.42 (11.9)
1.0 (28.3)
2.5 (70.8)
5.0 (141.6)
Series
P3
Polypropylene Flow Switch
Flow Switches,
Shuttle/Piston
Fixed Set Points from 0.25 to 2.0 GPM, 3/8” NPT or “Quick Disconnect” Adapters
3/4 [19.05] ACROSS FLATS
11/16 HEX [17.46]
1
[25.40]
7/16
[11.11]
3/4 [19.05] ACROSS FLATS
4-15/64
[107.55]
QUICK DISCONNECT
PORTS
11/16 HEX [17.46]
3/8 NPT PORTS
1
[25.40]
4
[101.60]
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing:
Polypropylene; Piston: PPS composite;
Spring: 316SS; O-ring: Flourocarbon.
Temperature Limits: 0 to 212°F (-18
to 100°C).
Pressure Limits: 125 psig (8.6 bar) @
70°F (21°C), 50 psig (3.4 bar) @ 212°F
(100°C).
Accuracy: 20% of set point.
Repeatability: ±1%.
Switch Type: SPST, N.O.
Fit almost any piping requirements with the Series P3 Polypropylene Flow Switch.
The basic piston design consists of a hermetically sealed SPST normally open reed switch.
Choose the inlet and outlet port to be 3/8˝ male NPT or 1/4˝ male “Quick Disconnect”.
Select a quick disconnect acetal adapter for straight through flow or with a shut off valve.
The shut off valve will stop line flow when the adapter is removed from the switch. The flow
will resume when the adapter is reconnected. With many snap-on fittings to choose from,
any flow application can integrate the P3 Flow Switch into the existing piping.
Model
P3-31
P3-32
P3-33
P3-34
P3-35
P3-41
P3-42
P3-43
P3-44
P3-45
208
Connection
3/8˝ NPT
3/8˝ NPT
3/8˝ NPT
3/8˝ NPT
3/8˝ NPT
Q Disconnect
Q Disconnect
Q Disconnect
Q Disconnect
Q Disconnect
Actuation Set Point
GPM (LPM)
0.25 (.95)
0.50 (1.89)
1.0 (3.79)
1.5 (5.68)
2.0 (7.57)
0.25 (.95)
0.50 (1.89)
1.0 (3.79)
1.5 (5.68)
2.0 (7.57)
VISIT OUR WEBSITES:
Electrical Rating: .08A @ 120 VAC.
Electrical Connection: 24˝ (60.96 cm),
polymeric wire leads, 22 AWG.
Process Connection: 3/8˝ male NPT
or 1/4˝ quick disconnect.
Mounting Orientation: Any position.
Set points shown are based on
vertical, inlet down position.
Required Filtration: 100 microns or
better.
Weight: 5 oz (0.14 kg).
Agency Approvals: CE.
Adapters (Price shown per unit, need two per switch)
Model
Connection
P3-801
Quick disconnect straight through 1/4˝ NPT
P3-802
Quick disconnect straight through 1/4˝ BSPT
P3-804
Quick disconnect straight through 3/8˝ BSPT
P3-807
Quick disconnect straight through 1/4˝ ID tubing
P3-901
Quick disconnect straight through 1/4˝ NPT w/shut-off valve
P3-902
Quick disconnect straight through 1/4˝ BSPT w/shut-off valve
P3-907
Quick disconnect straight through 1/4˝ ID tubing w/shut-off valve
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
209:Layout 2
7/13/11
2:49 PM
Page 1
Series
P8
High Pressure Brass Flow Switch
Up to 1500 psi, Fixed Setpoint, Up to 2.0 GPM, Rugged Brass Body
3/8 NPT TYP
1-9/64
[28.97]
3/4 HEX
[19.05]
3-29/64
[87.71]
High inline pressures are no problem for the Series P8 brass flow switch. The switch
integrates a one-piece magnetic PPS composite piston to handle pressure up to 1500 psi.
The P8 switches use 100 micron filtration and are less susceptible to clogging than other
high inline pressure switches. Setpoints range from 0.25 to 2.0 GPM for liquid flow. Use
the Series P8 in industrial cleaning equipment or high pressure lubrication systems.
Actuation Set Point
GPM (LPM)
0.25 (.95)
0.50 (1.89)
1.0 (3.79)
1.5 (5.68)
2.0 (7.57)
Series
P4
PPS Piston Flow Switch
9/16-18 UNF-28
TYP 2 PLACES
19/32
[15.03]
1
[25.40]
1-17/64
[32.15]
The Series P4 PPS Flow Switch features a molded plastic construction for enhanced
performance. Monitor liquids with fixed set points from 0.1 to 1.5 GPM. Choose normally
open or normally closed SPST or SPDT hermetically sealed reed switch technology. The
industrial switch features PPS R4 housing and piston, 316SS spring, Fluoroelastomer Oring and Epoxy. The inlet and outlet ports are 9/16˝-18 UNF-28 thread with optional 1/8˝
and 1/4˝ NPT or 1/2˝ barbed adapters.
Actuation Set Point
GPM (LPM)
.1 (.38)
.25 (.95)
.5 (1.89)
.75 (2.84)
1 (3.7)
1.5 (5.68)
.1 (.38)
0.25 (.95)
0.5 (1.89)
0.75 (2.84)
1.0 (3.79)
1.5 (5.68)
CALL TO ORDER:
Switch Type
SPST, N.O.
SPST, N.O.
SPST, N.O.
SPST, N.O.
SPST, N.O.
SPST, N.O.
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
U.S. Phone 219 879-8000
3-41/64
[92.47]
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing and piston:
Polyphenylene sulfide (PPS) R4;
Spring: 316 SS; O-ring:
Fluoroelastomer; Other: Epoxy.
Temperature Limits: 0 to 225°F (17 to
107°C).
Pressure Limits: 250 psig (17 bar) @
54°F (12°C).
Accuracy: ±15% of set point.
Repeatability: ±1%.
Switch Type: SPST or SPDT.
59/64
[23.42]
Electrical Rating: .17A @ 120 VAC,
.08A @ 240 VAC, .13A @ 120 VDC, .06A
@ 240 VDC.
Electrical Connection: 18 AWG, 24˝
(60.96 cm), PVC lead wires.
Process Connection: 9/16-18 UNF-28
or choice of connection adapters (sold
separately).
Mounting Orientation: Any position.
Set points shown are based on vertical,
inlet down position.
Required Filtration: 50 microns or
better.
Weight: 4 oz (0.11 kg).
Agency Approvals: CE.
Optional Adapters
Model
Description
P4-98
1/8˝ NPT female
P4-94
1/4˝ NPT female
P4-92
1/2˝ barb female
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
209
Flow Switches,
Shuttle/Piston
Fixed Set Points from 0.1 to 1.5 GPM, SPST and SPDT Switching, Optional Adapters
Model
P4-11
P4-12
P4-13
P4-14
P4-15
P4-16
P4-31
P4-32
P4-33
P4-34
P4-35
P4-36
FLOW
Model
P8-11
P8-12
P8-13
P8-14
P8-15
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing: Brass; Piston: PPS composite, epoxy; Spring: 316SS;
O-ring: Flourocarbon.
Temperature Limits: -20 to 275°F (-28 to 135°C).
Pressure Limits: 1500 psi (103.4 bar).
Accuracy: ±20% of set point.
Switch Type: SPST, N.O.
Electrical Rating: .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240
VDC.
Electrical Connection: No. 22 AWG, 24˝ (61 cm), polymeric leads.
Process Connections: 3/8˝ male NPT.
Mounting Orientation: Any position. Set points shown are based on vertical, inlet
down position.
Required Filtration: 100 microns or better.
Weight: 6 oz (.17 kg).
Agency Approvals: CE.
210:Layout 2
7/13/11
2:50 PM
Page 1
Series
P1
Brass Flow Switch
Fixed Setpoints, Flow Rates from 0.10 to 1.5 GPM
1/2 NPT
1
[25.4]
1/2
[12.7]
(1/4 TYP)
[6.35 TYP]
IN
1/2
[12.7]
1/4 NPT
2-3/8
[60.33]
1-3/4
[44.45]
2X (Ø9/32)
[Ø7.14]
1/4 NPT
OUT
1
[25.4]
1-1/4
27/32 [31.75]
[21.43]
4-1/8 [104.78]
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing: Brass;
Piston: Polysulfone; Spring: 316SS; ORing: Fluoroelastomer; Other: Epoxy.
Temperature Limits: -20 to 225°F (-29
to 107°C).
Pressure Limits: 1000 psig (68.9 bar).
Accuracy: ±10% of set point.
Repeatability: ±1%.
Switch Type: SPDT.
Electrical Rating: .17A @ 120 VAC,
.08A @ 240 VAC, .13A @ 120 VDC, .06A
@ 240 VDC.
FLOW
The Series P1 Brass Flow Switch utilizes a piston-type design for accurate detection
of excessive or insufficient flow rates. The piston magnetically actuates a hermetically
sealed SPDT reed switch. The switches have preset actuation points from 0.10 to 1.5 GPM
for liquid flow. The Series P1 is ideal for protecting against loss of fluid flow in hydraulic
systems or assuring proper coolant flow in semiconductor processing.
Model
P1-011
P1-012
P1-013
P1-014
P1-015
P1-016
Actuation Set Point*
GPM (LPM)
0.10 (.38)
0.25 (.95)
0.50 (1.89)
0.75 (2.84)
1.00 (3.79)
1.50 (5.68)
Electrical Connection: 18 AWG, 24˝
(60.96 cm), polymeric lead wires.
Process Connection: 1/4˝ female
NPT.
Mounting Orientation: Any position.
Set points shown are based on vertical,
inlet down position.
Required Filtration: 50 microns or
better.
Weight: 0.66 Ib (301 g).
Agency Approvals: CE.
*Calibrated for water at standard conditions.
Series
AFS
Adjustable Flow Switch
Flow Switches,
Shuttle/Piston
For Oils, Water and Gases, Infinite Adjustments
2
[50.80]
3/4
[19.05]
1/2 NPT
BOTH ENDS
1-1/4
[31.75]
The Series AFS Adjustable Flow Switch is externally adjustable and is ideal for
protecting machine tools from coolant flow failure, protecting bearings from loss of
lubricant or assuring proper air flow. The Series AFS offers an infinite number of flow
settings from 0.5 to 20 GPM at pressures up to 1000 psig, with low pressure drop and
precise repeatability. The AFS is housed in either brass or stainless steel and can be used
with water, compatible liquids, oils, and gases.
Model
AFS-131
AFS-141
AFS-151
AFS-231
AFS-251
AFS-132
AFS-142
AFS-152
AFS-232
AFS-252
210
Media
Oil
Water
Liquids
Gases
Gases
Oil
Water
Liquids
Gases
Gases
Electrical
Connection
Wire leads
Wire leads
Wire leads
Wire leads
Wire leads
1/2˝ NPT conduit
1/2˝ NPT conduit
1/2˝ NPT conduit
1/2˝ NPT conduit
1/2˝ NPT conduit
Piston
Brass
Polysulfone
316SS
Brass
316SS
Brass
Polysulfone
316SS
Brass
316SS
VISIT OUR WEBSITES:
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: Housing and Piston: See model chart; Spring: 316SS; O-ring:
Fluoroelastomer; Other: Epoxy.
Temperature Limits: -20 to 300°F (-29 to 149°C), -20 to 225°F (-29 to 107.2°C)
with polysulfone piston.
Pressure Limit: 1000 psi (68 bar).
Accuracy: ±10% of setpoint.
Repeatability: ±1% maximum deviation.
Switch Type: SPDT.
Electrical Rating: .17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240
VDC.
Electrical Connections: 18 AWG, 24˝ (61 cm), polymeric lead wires, optional 1/2˝
male NPT conduit connection.
Process Connection: 1/2˝ female NPT ports.
Mounting Orientation: Any.
Setpoint Adjustment: Liquids: 0.5 to 20 GPM (1.9 to 75.7 LPM); Gases: 1.0 to 75
SCFM (28 to 2124 LPM) at 5 psig.
Required Filtration: 50 microns or better.
Weight: 2 lb, 11 oz (1.22 kg).
Agency Approvals: CE.
Housing
Brass
Brass
316SS
Brass
316SS
Brass
Brass
316SS
Brass
316SS
www.dwyer-inst.com
4-1/8
[104.78]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
211:Layout 2
8/4/11
3:32 PM
Page 1
Series
P5
PVC Shuttle Flow Switch
Low Cost Flow/No Flow Monitoring, Visual Flow Indication, Broad Chemical Compatibility
ø1-5/8
[ø41.28]
DIM “B”
(2-5/16)
[58.74]
(2-1/16)
[52.39]
(1-15/16)
[49.21]
DIM “A”
1/2 NPT
3-13-16
[96.84]
OR 4-3/8
[111.13]
W/ 1/2 NPT
PORT ADAPTER
A
2 PLACES
3/4 IPS
1 IPS
B
1-1/2 [38.1]
OR 2-1/16 [52.39]
W/ 1/2 NPT PORT ADAPTER
Model
P5-1
P5-2
P5-3
Actuation Set Point
GPM (LPM)
.5 (1.89)
.5 (1.89)
2.0 (7.57)
Process Connection
1/2˝ NPT port adapter
3/4˝ IPS
1˝ IPS
Series
FMS
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing, shuttle
and bonnet: PVC; O-ring: Buna-N;
Epoxy.
Temperature Limits: 120°F (49°C).
Pressure Limit: 120 psig (8.2 bar) @
70°F (21°C) to 100°F (38°C), 50 psig
(3.45 bar) @ 101°F (38.3°C) to 120°F
(49°C).
Accuracy: ±20% of set point.
Repeatability: ±1%.
Switch Type: SPST, N.O.
Electrical Rating: .17A @ 120 VAC,
.08A @ 240 VAC, .13A @ 120 VDC, .06A
@ 240 VDC.
Electrical Connection: 22 AWG, 24˝
(61 cm), PVC lead wire.
Process Connection: 1/2˝ female
NPT, 3/4˝ IPS or 1˝ IPS.
Required Filtration: 150 microns or
better.
Mounting Orientation: Vertical, inlet
facing down.
Weight: 6 oz (.17 kg).
Agency Approvals: CE.
Flow Switches,
Shuttle/Piston
Flow Sensor
For Water and Water Based Liquids/Oil and Oil-Based Liquids
1-11/32
[34]
3-3/16 [80.88]
1/2
[12.7]
Ø1-31/32
[Ø49.8]
Ø21/32
[Ø16.51]
1/2-14 NPT
M12 4 PIN CONNECTOR
Series FMS Flow Sensor FMS-1 is for applications requiring RELATIVE
measurement and set-point of flow rate. This means that the actual velocity of the flow or
the quantitative measurement in GPM is not known and is not important. What is
important is that the set-point can be set as a “percentage of” or “relative to” the full flow
rate. No other flow sensor could do it this simply or effectively.
How It Operates
The model FMS uses a set of flashing LED’s to indicate flow. All 7 of the LED’s will
remain lit to show 100% flow rate. The flow OK light will also be lit showing that the
established full flow rate is what is flowing in the pipe. When you initially set the flow
rate, it will mark that as your 100% mark. If your flow reduces below the 50% mark,
you will get an alarm from the sensor.
If flow increases beyond the initially established flow rate, the “Overflow” LED light
will come on.
Model FMS-1, Flow Sensor PNP N.O.
Model FMS-2, Flow Sensor PNP N.C.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
49/64
[19.56]
SPECIFICATIONS
Service: Water and water based
liquids/oil and oil-based liquids.
Wetted Materials: Sensor head: 303
SS.
Low Flow Set Point: Auto set @ 50%
/ adjustable via “set” push button.
Set Point Range: 5.0 ft/sec (0-150
cm/sec.)
Repeatability: < 0.5%.
Hysteresis: 10% of set-point value
typical.
Medium Temperature Limits: -4 to
176°F (-20 to 80°C.)
Pressure Limit: 450 psi (30 bar).
Response Time: 25 seconds (typical).
U.K. Phone (+44) (0)1494-461707
•
FLOW
The transparent Series P5 Shuttle Flow Switch features corrosion resistant, durable
PVC housing for visual confirmation in flow/no flow applications. The switches have preset
actuation points from 0.5 to 2.0 GPM for actuation on increasing flow. Switching is SPST
normally open at no flow. Choose from 1/2˝ NPT or 3/4˝ IPS (for 0.5 GPM) or 1˝ IPS (for
2.0 GPM) inlet and outlet ports. The shuttle design has only one moving part for long life
and minimum maintenance. Remove the one-piece bonnet and shuttle assembly to quickly
clean the unit without disturbing the housing or piping. Rugged construction and excellent
chemical compatibility simplify flow / no flow detection.
1-1/16 HEX
[27 HEX]
Supply Voltage: 20-30 VDC (short
circuit protected).
Switching Current: < 200 mA.
Power Consumption: 6 W max.
Electrical Connection: M12 male
socket 4-pin. Comes with 6.5 ft (2 m)
cable with M12 connector and pigtail.
Process Connection: 1/2˝ male NPT.
Enclosure Rating: NEMA 4 (IP65).
Initial Operation: After 15 seconds.
Switch Type: PNP N.O. (switch closed
with flow), PNP N.C. (switch open with
flow).
Weight: .55 lb (.25 kg).
Australia Phone (+61) (0) 2 4272 2055
211
TDFS_Layout 7 7/19/11 4:14 PM Page 1
Series
TDFS
Thermal Dispersion Flow Switch
Non-Mechanical, Low Pressure Drop
RoHS
CABLE
CABLE GLAND
STATUS
INDICATOR
4-9/32
[108.74]
SETPOINT
TARGET
1-7/16
[36.51]
PROCESS CONNECTION
1/2˝ NPT
SENSOR
Flow Switches,
Thermal
FLOW
1-1/8
HEX
The Series TDFS is a thermal flow switch that indicates whether the flow rate
is above or below a user set flow rate with NO and NC NPN outputs. Setpoint
is easily field set, just tap the included magnet on the setpoint target three times
at the desired flow rate and it’s done. Incorporated into the unit are two LED
status indicators on opposite sides of the unit providing visual switch indication,
green when the flow is above set point, red when the flow is below set point.
SPECIFICATIONS
Service: Compatible water-based fluids.
Wetted Materials: 316 SS, Polysulfone, and FKM.
Setpoint Range: 0.5 to 10 ft/s (0.15 to 3.0 m/s).
Repeatability: 0.07 ft/s +3% of setpoint.
Typical Deadband: 0.1 ft/s +15% of setpoint.
Temperature Limits: Process: 5 to 185°F (-15 to 85°C) (non-freezing);
Ambient: 5 to 167°F (-15 to 75°C), Storage: -40 to 185°F (-40 to 85°C).
Pressure Limits: 150 psig (10.34 bar), max. momentary surge: 500
psig (34.47 bar).
Response Time: Approximately 8 s.
Power Requirement: 9 to 24 VDC.
Switching Current: 400 mA, derate 5 mA/°C above 23°C.
Current Consumption: Average: 93 mA, Peak: 300 mA.
Electrical Connection: 4 conductor 22 AWG, 6´ (1.83 m) long with
cable gland.
Process Connection: 1/2˝ NPT male.
Enclosure Rating: NEMA 4X (IP65).
Housing Materials: 316 SS, 416 SS, polycarbonate, neoprene, and
acrylated urethane.
Switch Type: 1 NO NPN, 1 NC NPN.
Input Power and Protection: 0.5A fuse (resettable) reverse polarity
protected.
Switched Output Protection: 0.5A fuse (resettable) reverse polarity
protected.
Agency Approvals: CE, RoHS.
The TDFS uses an impulse thermal dispersion measurement technique to
measure the flow rate where the probe is heated above the process temperature
and then is allowed to cool down to the process temperature. Empty pipe is not
a problem with the TDFS unlike some competitor units that will overheat.
Thermal flow switches can offer better long term reliability and life expectancy
than mechanical flow switches.
TDFS Advantages over Mechanical Flow Switches
• No paddles or vanes to break off into the flow
• No jams or material stopping the paddle movement
• No seals on movement assembly to wear or leak
• Low pressure drop, only needs to be 10% into the flow (e.g. 1/8˝ for 3/4˝
schedule 40 pipe)
TDFS-1-P-06, Thermal flow switch, 6´ cable with cable gland
Consult factory for longer cable lengths
NEW PRODUCT!
212
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
213:Layout 2
7/13/11
3:07 PM
Page 1
Series
TSP
Liquid Flow Controller
NO or NC Relay Output, Adjustable Time Delay
Model
TSP110
TSP210
TSP120
TSP220
TSP110S
TSP210S
TSP120S
TSP220S
DIM “A”
in (cm)
6-1/2 (165.1)
6-1/2 (165.1)
7-29/32 (200.82)
7-29/32 (200.82)
8-5/16 (211.14)
8-5/16 (211.14)
9-13/16 (249.24)
9-13/16 (249.24)
DIM “B”
in (cm)
1-5/16 (33.34)
1-5/16 (33.34)
2-13/16 (71.44)
2-13/16 (71.44)
1-9/64 (28.97)
1-9/64 (28.97)
2-13/16 (71.44)
2-13/16 (71.44)
Protect pumps and valves from dry running with the Series TSP Liquid Flow
Controller. The Series TSP combine a liquid flow switch with a failsafe relay controller to
detect a flow or no flow situation and provides switching for direct actuation of pumps and
valves. Controller features adjustable time delay, selectable NO or NC operation, and LED
indication of sensor, relay, and power status. Four models (TSP110S, TSP210S, TSP120S,
TSP220S) are designed with an integral flash alarm to provide immediate indication of
local alarm conditions.
Flash Alarm
No
No
No
No
Yes
Yes
Yes
Yes
Wetted Parts
PP
PVDF
PP
PVDF
PP
PVDF
PP
PVDF
Sensor Length
Short
Short
Long
Long
Short
Short
Long
Long
“A”
“C”
“B”
Ø2-13/16
[Ø71.44]
3-5/16
[84.14]
3-29/32
[99.22]
“A”
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Polypropylene/PPS
or polyvinylidene fluoride.
Temperature Limits: -40 to 158°F
(-40 to 70°C).
Pressure Limits: 150 psi (10 bar) @
77°F (25°C), derated 1.67 psi (.113 bar)
per °C above 25°C.
Relay Output: 1 SPDT form C, isolated
and sealed.
Relay Load: 250 VAC, 10 A resistive,
1/2 hp.
Switching Mode: Selectable NO or NC.
Supply Voltage: 120/240 VAC, 50/60
Hz, selectable.
Current Consumption: .25 amps
maximum.
*Applies to models with flash alarm only.
“C”
“B”
Sensor Voltage Supply: 13 VDC, 1
Watt max., nominal.
Sensor Trigger Point: Dry <10 mA, wet
>10 mA.
Time Delay: Adjustable, 0.15 to 60
seconds.
Flash Type: *Xenon tube.
Flash Frequency: *1 per second.
Brightness: *>50,000 CP.
Strobe Life: *10 M cycles.
Conduit Connection: 1/2˝ NPT.
Mounting Connection: 3/4˝ NPT.
Enclosure: Polypropylene, flame
retardant, probe NEMA 4X (IP65).
Agency Approvals: CE.
Thermal Dispersion Flow Switch
Flow Switches,
Thermal
Series
TDS
3-5/16
[84.14]
3-29/32
[99.22]
Adjustable Switch Point, LED Indication
3/4 NPT
Dim. TDS112, TDS212 TDS122, TDS222
A
3.0˝ (7.6 cm)
4.5˝ (11.4 cm)
B
0.7˝ (1.8 cm)
2.1˝ (5.3 cm)
Ø45/64
[17.86]
Ø1-1/16
[26.99]
"B"
"A"
The Series TDS Thermal Dispersion Flow Switch offers solid state flow detection
of non-coating liquids for pump and process protection. SPDT output allows for interfacing
with remote PLC or relay control device. The adjustable switch point is factory calibrated
at 0.2 fps with LED indication of flow and calibration status. Units feature selectable NO
or NC operation and are not damaged by overranging flow velocities.
Model
TDS112
TDS212
TDS122
TDS222
Wetted Parts
PP/PPS
PVDF
PP/PPS
PVDF
CALL TO ORDER:
Length
3.0˝ (7.6 cm)
3.0˝ (7.6 cm)
4.5˝ (11.4 cm)
4.5˝ (11.4 cm)
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Service: Liquids.
Wetted Materials: Polypropylene /PPS
or polyvinylidene fluoride.
Range: 0.04 to 10 fps (1.2X10-2 to 3.05
m/s)
Temperature Limits: 32 to 140°F (0 to
60°C).
Pressure Limits: 150 psi (10 bar) @
25°C, derated @ 1.667 psi (.113 bar)
per °C above 25°C.
Repeatability: ±5% of setpoint.
Switch Type: SPDT.
Electrical Rating: 60 VAC/60 VDC @
1 A.
Electrical Connections: 22 AWG 3wire, 10 ft (3 m) length.
U.K. Phone (+44) (0)1494-461707
•
FLOW
Model
TSP110
TSP210
TSP120
TSP220
TSP110S
TSP210S
TSP120S
TSP220S
Ø2-13/16
[Ø71.44]
DIM “C”
in (cm)
45/64 (17.86)
45/64 (17.86)
2-7/64 (53.58)
2-7/64 (53.58)
45/64 (17.86)
45/64 (17.86)
2-7/64 (53.58)
2-7/64 (53.58)
Process Connections: 3/4˝ male NPT.
Mounting Orientation: Any
orientation, for pipe sizes 3/4˝ to 1-1/2˝
use 3.0˝ (7.6 cm) length switch; for 2˝
to 16˝ pipe sizes use 4.5˝ (11.4 cm)
length switch.
Setpoint Adjustment: 0.04 to 3 fps
(1.2X10-2 to .91 m/s).
Setpoint Drift: 0.5% of setpoint.
Response Time: 1-10 seconds.
Viscosity Range: 1 to 200 centipoise.
Supply Voltage: 12 to 36 VDC.
Consumption: 50 mA (nominal).
Indication: LED for flow status.
Weight: 3 oz (94 g).
Agency Approvals: CE.
Australia Phone (+61) (0) 2 4272 2055
213
214:Layout 2
7/20/11
3:16 PM
Page 1
Series
FTS
Thermal Flow and Temperature Switch
For Industrial Cooling Systems
A-284
1/2˝ NPT
43/64 1-1/16 HEX
[17]
[26.9]
53/64
[21.0]
FLOW
Series FTS Thermal Flow Switch is especially designed, for all types of cooling systems,
as a reliable alternative to failure prone mechanical flow switches. The thermal flow switch
continually samples the temperature of the coolant and adjusts the low flow setpoint
automatically, providing a solid state switch should the coolant flow rate fall below the
setpoint value. In addition, the thermal flow switch will provide an alarm output should the
coolant temperature rise above acceptable levels. You have double protection with the FTS.
Model
FTS-AS
FTS-AL
FTS-BS
FTS-BL
Temp. Set Point
122°F (50°C)
122°F (50°C)
158°F (70°C)
158°F (70°C)
SPECIFICATIONS
Service: Water based liquids.
Low Flow Set Point: .4 m/s (1.2 fps) (water related) typical.
Temperature Set Point: 122°F (50°C) or 158°F (70°C), other settings possible on
OEM demand.
Temperature Limits: -4 to 176°F (-20 to 80°C).
Response Time: 5 to 10 seconds.
Repeatability: 0.5%.
Hysteresis: <20% of set-point value.
Pressure Limit: 150 psi (10 bar).
Protection Class: NEMA 6 (IP 67).
Wetted Material: 303 SS.
Process Connection: 1/2˝ male NPT.
Electrical Connection: M12 male socket 4 pin with 6 ft (2 m) connection cable
with M12 connector sold separately.
Power Requirement: 18-30 VDC.
Electrical Rating: <200 mA.
Power Consumption: 4 W max.
Initial Operation: After 15 seconds.
Switch Type: PNP N.O. (switch closes with flow).
Sensor Length (L)
1/2˝ (12.7 cm)
2˝ (50.8 cm)
1/2˝ (12.7 cm)
2˝ (50.8 cm)
ACCESSORY
A-284, Wiring cable 6 ft (2 m) long with M12 connector
Flow Switches,
Thermal
Series
TDC
L
7/8
[22.2]
Remote Flow Controller
Single or Dual Relay Output, Adjustable Time Delay
3-29/32 [99.21]
2-13/16
[71.44]
1-13/16
[46.04]
3-7/64 [78.98]
3-45/64 [94.06]
Series TDC Remote Flow Controller coupled with a thermal dispersion flow switch
(Series TDS) provides a complete system for leak detection, signaling high or low flow
conditions, low flow cutoff, and pump or valve actuation. Controller features adjustable
time delay for dampening of relay chatter, selectable NO or NC operation, and LED
indication of sensor, relay, and power status. Model TDC1 accepts single switch input
and single relay output. Model TDC2 accepts three switch inputs and two relay outputs.
Model
TDC1
TDC2
214
SPECIFICATIONS
Relay Output: TDC1: 1 SPDT form C; TDC2: 2 SPDT form C (one latching relay).
Relay Load: 240 VAC, 12 A resistive, 1/2 HP.
Switching Mode: Field selectable NO or NC.
Supply Voltage: 120/240 VAC, 50/60 Hz., selectable.
Current Consumption: .25 amps maximum.
Time Delay: Adjustable, 0.15 to 60 seconds.
Sensor Voltage Supply: 13.5 VDC, 100 mA max., nominal.
Sensor Trigger Point: Dry <12 mA; Wet >12 mA.
Sensor Input: Terminal block.
Mounting: EN 50 022 standard 32 mm DIN or panel mount.
Enclosure: Polypropylene, flame retardant.
Temperature Limits: -4 to 158°F (-20 to 70°C).
Agency Approvals: CE.
Description
Single Point Flow Controller
Dual Point Flow Controller
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
215:Layout 2
7/13/11
3:12 PM
Page 1
Series
BFM
Bulk Flow Monitor
Monitors Movement of Solids and Liquids
3[76.20]
6X 1/2˝ CONDUIT KNOCKOUT
4x 3/4˝ CONDUIT
KNOCKOUTS
RED LED
7
[177.80]
1-1/2
[38.10]
BFS
The BFS-1 Sensor yields many advance features. It externally mounts to the outside of
the pipe or chute. It provides mounting tabs for easy installation. The Sensor is prewired
with 3´ wire.
Series BFM has many practical applications. You can use it to monitor oil spray systems,
discharge chutes, distributors, screw conveyors, drag conveyors, water systems, air
systems, pneumatic systems, gravity feed systems, slurry systems, chemical processing,
food processing and rotary drums.
BFS Specifications
Pipe Size: 1/2˝ to 60˝ (1.27 to 152.4 cm).
Enclosure Rating: NEMA 4X (IP66).
Electrical Connection: 3´ (0.9 m) of 18 gauge wire.
Temperature Limits: 155°F (68.3°C).
Materials: PVC type 1 grade 1 grey.
Weight: 5 oz (141.8 g).
Descriptions
Control Unit: NEMA 4X, Polycarbonate Housing, 120VAC
Control Unit: NEMA 4X, Polycarbonate Housing, 220VAC
Control Unit: NEMA 4X, Polycarbonate Housing, 12VDC
Sensor
Flow Switches,
Piezo
Compressed Air Meter
Steady-State and Cumulative Totals PNP/4-20 mA Output
4-3/8
[111.13]
3-15/16
[100.01]
Dimensions
Model
A
M12 x 1
10-53/64
CAM-10 [275.3]
C
8-9/32
CAM-20 [210.34]
14-49/64
CAM-30 [375.05]
3-1/32 C
[76.99]
D
B
18-45/64
[475.06]
11-13/16
[300.04]
18-45/64
[475.06]
C
2˝ NPT
D
Ø2-1/64
[Ø51.2]
1/2˝ NPT Ø41/64
[Ø16.27]
1˝ NPT
Ø1-5/64
[Ø27.38]
A
B
The Series CAM Compressed Air Meter operates by the calorimetric measuring
principle to detect the standard volume flow of operating compressed air. It is designed
specifically to evaluate the current flow rate and the current consumed quantity in
compressed air systems. With an easily programmable digital display, this unit offers a
quick, accurate readout. The Series CAM is constructed of high-grade materials and is
virtually maintenance free.
Model CAM-10, 2˝ NPT, 1.4 - 412.0 SCFM
Model CAM-20, 1/2˝ NPT, 0.2 - 44.1 SCFM
Model CAM-30, 1˝ NPT, 1.0 - 132.4 SCFM
ACCESSORY
A-283, 4-Wire Connector
Max. Oil Content
Oil
Content
Class mg/m3
0.01
1
0.1
2
1
3
5
4
25
5
–
6
CALL TO ORDER:
Max. Residual Dust
Dust
Particle
Concentration Size
mg/m3
mg/µm
0.1
0.1
1
1
5
5
8
15
10
40
–
–
Max. Residual Water
Residual Pressure
Water
Dew Point
g/m3
°C
0.003
-70
0.117
-40
0.880
-20
5.953
+3
7.732
+7
9.356
+10
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Service: Compressed air; Air quality (see chart).
Wetted Materials: Stainless steel (304S15), ceramics, glass passivated, PEEK,
polyester, fluoroelastomer, anodized aluminum.
Accuracy: Class 1.4.1: ±3% of measured value +0.3% of full scale value; Class
3.4.4: ± 6% of measured value + .6% of full scale value.
Response Time: < 0.1 seconds.
Temperature Limit: 32 to 140°F (0 to 60°C).
Pressure Limit: 232 psig (16 bar).
Humidity Limit: 90% RH.
Power Requirements: 19-30 VDC.
Output Signal: Output 1: PNP open collector: VOUT(max)=30 VDC /
ISINK(max)=250mA; Output 2: 4-20 mA (scaleable) or PNP open collector.
Loop Resistance: 500 ohms.
Current Consumption: <100 mA.
Electrical Connections: 4 pin M12 (micro) cable connection.
Process Connections: 1/2˝, 1˝ and 2˝ NPT.
Display: 4-digit alpha numeric red LED.
Enclosure Rating: IP65 (NEMA 4X).
Mounting Orientation: Vertical, horizontal, side with pipe length facing left.
Weight: CAM-10: 12.5 lb; CAM-20: 2.35 lb; CAM-30: 4.16 lb.
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
FLOW
SPECIFICATIONS
BFM Specifications
Service: Solids and liquids.
Power Requirement: 120VAC, 220VAC or 12VDC.
Power Consumption: .1A.
Temperature Limits: 120°F (48.9°C).
Output: Relay: SPDT rated 4A @ 125/250VAC, 1/10 HP @ 125/250VAC, 3A @
30VDC. TTL: 0-5 V.
Serial Communications: RS-232.
Electrical Connection: Screw terminal.
Conduit Connection: Knockouts (four 3/4˝ for power, six 1/2˝ for sensor and
outputs).
Enclosure Rating: NEMA 4X (IP66).
Material: Polycarbonate.
Weight: 3 lb (1.36 kg).
The BFM Control offers many unique advance features that exceed the industry
standards. The BFM Central Processing Unit monitors movement of almost anything
through a pipe or chute system. The BFM is ideal for sensing the presence or absence of
materials in Pneumatic Conveying Systems. The BFM offers adjustable sensitivity
depending on the application demand. Also, it provides easy installation and requires no
maintenance. The unit has LED indicators – flow (green)/ no flow (red).
Series
CAM
3/32
[2.29]
3´ 18 AWG
WIRE
FLOW SENSOR
SENSITIVITY ADJUSTMENT
POTENTIOMETER
BFM FLOW MONITOR
Series BFM Bulk Flow Monitor provides effective monitoring for most flow/no flow
conditions in pipes and chutes. It’s sensing techniques, which use a Piezo element, makes
the BFM versatile for most flow/no flow applications.
Model
BFM-1
BFM-2
BFM-3
BFS-1
3
[76.20]
SENSOR TIP
5-9/64 [130.45]
BFM
1/2
[12.69]
1-19/32
[40.64]
GREEN
LED
Australia Phone (+61) (0) 2 4272 2055
215
216:Layout 2
7/13/11
3:12 PM
Page 1
Series
HFT
In-Line Flow Transmitters
Local Flow Indication, Unrestricted Mounting, 4-20 mA, 0-5 V, and 1-5 V Output
7-1/8
[180.98]
4-1/2
[114.3]
The Series HFT combines a direct reading HF flowmeter with electronics to provide a
proportional analog output of 4-20, 0-5, and 1-5 VDC. Use the output to drive data acquisition
devices, meters, or analog input cards. The entire assembly is housed in a rugged cast
aluminum NEMA 4X enclosure. The unit can be installed in outdoor applications or harsh
environments where liquid tight seals are required. The flow transmitter does not require
input or output straight plumbing, and can be mounted in any orientation.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials: Body: Aluminum,
brass or 304 SS; Seals: Buna-N or
Fluoroelastomer; Magnet: PTFE
coated Alnico; Other internal parts: 304
SS.
Viscosity: 500 SSU.
Accuracy: ±4% FS over entire range;
±2.5% over center third of the
measuring range.
Repeatability: ±1% of full scale.
FLOW
Aluminum body for air or other non-corrosive gases: 600 psig (41 bar)
Wetted Parts: Aluminum, PTFE coated Alnico, 304 SS and Buna-N
Model
Range, Air SCFM
Connection Size
HFT-1112 1/4˝ female NPT
1.5-12
HFT-1123 1/4˝ female NPT
4-23
Brass body for water based fluids (non-steam): 3500 psig (240 bar)
Wetted Parts: Brass, PTFE coated Alnico, 304 SS and Buna-N
Range, Water GPM (LPM)
Model
Connection Size
0.5-5.0 (1-19)
HFT-2205 1/2˝ female NPT
1-15 (3.8-55)
HFT-2315 3/4˝ female NPT
2-20 (7.5-75)
HFT-2320 3/4˝ female NPT
4-40 (15-151)
HFT-2440 1˝ female NPT
5-50 (19-189)
HFT-2550 1-1/2˝ female NPT
Flow Transmitters,
In-Line
Series
DFT
Response Time: <100 msec.
Output Signal: 4-20 mA; 0-5 V; 1-5 V.
Temperature Limits: 240˚F (116˚C).
Pressure Limits: See chart.
Power Requirements: 12-35 VDC.
Enclosure Rating: NEMA 4X (IP65).
Shipping Weight: 1/4 to 1/2˝ female
NPT models: 3 lb (1.4 kg); 3/4 to 1˝
female NPT models: 4.5 lb (2.0 kg);
1-1/2˝ female NPT models: 12 lb
(5.4 kg).
304 SS body for high-pressure fluids: 6000 psig (413 bar)
Wetted Parts: 304 SS, Fluoroelastomer and PTFE
Range, Water GPM (LPM)
Model
Connection Size
0.2-2.0 (0.75-7.5)
HFT-3202 1/2˝ female NPT
1-10 (3.8-38)
HFT-3210 1/2˝ female NPT
Inline Differential Flow Transmitter
Low Cost, Compact and Rugged Design
6-7/8
7-1/2
[174.63]
[190.5]
FOR 3/8˝ & 1/2˝ FOR 3/4˝
2-7/32
[56.36]
5-1/4
[133.35]
1-3/32
[27.78]
FOR 3/8˝ & 1/2˝
1-5/16
[33.34]
FOR 3/4˝
Series DFT Flow Transmitters use a segmented wedge differential producer to measure
flow rates as related to pressure to monitor process fluids. The segmented wedge provides
a simple and reliable restriction for sensing flow as related to pressure differential. The
sensor can be mounted in any position and allows the designer to install it in any orientation:
horizontal, vertical or inverted. The sensor is offered with three flow measuring ranges: 0.55, 1-10 and 1-15 GPM and three electrical output signals: 4-20 mA, 1-5 VDC and 1-10 VDC.
The sensor offers low-cost precision with a measuring accuracy of ±2% of full-scale range
and repeatability of ±0.5%.
Model
DFT-PNW1-01C1
DFT-PNW1-02C1
DFT-PNW1-03C1
DFT-PNW1-01C2
DFT-PNW1-02C2
DFT-PNW1-03C2
DFT-PNW1-01C3
DFT-PNW1-02C3
DFT-PNW1-03C3
216
Flow Ranges
GPM (LPM)
0.5-5 (1.9-18.9)
0.5-5 (1.9-18.9)
0.5-5 (1.9-18.9)
1-10 (3.8-37.9)
1-10 (3.8-37.9)
1-10 (3.8-37.9)
1-15 (3.8-56.8)
1-15 (3.8-56.8)
1-15 (3.8-56.8)
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: End ports: PVC; Wedge element: PVC; Pressure sensor:
polyethermide.
Flow Measuring Ranges: 0.5-5, 1-10, 1-15 GPM.
Accuracy: ±2% of full-scale.
Repeatability: ±0.5% of full-scale.
Response Time: Indication of no less than 90% of any step change within <500ms.
Power Requirements: 12-35 VDC.
Output Signal: 4-20 mA (optional 0-5 VDC or 0-10 VDC consult factory).
Maximum Current Consumption: 25 mA.
Minimum Load Resistance: 1000 Ω.
Maximum Transmission Distance: 200 ft.
Resolution: Infinite.
Temperature Limits: 170°F (76°C).
Pressure Limits: 125 psig (8.6 bar).
Enclosure Rating: NEMA 4 (IP65).
Maximum Particulate Size: 200 microns.
Weight: 1 lb (0.45 kg).
Nominal Port Size
(NPT Female)
3/8˝
1/2˝
3/4˝
3/8˝
1/2˝
3/4˝
3/8˝
1/2˝
3/4˝
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
217:Layout 2
7/13/11
3:13 PM
Page 1
Series
SF
Sight Flow Transmitter
±2% FS Accuracy, 4 to 20 mA Output, Pressure up to 500 psig (34 bar)
2
[50.80]
1/2˝ FEMALE NPT
Series SF Sight Flow Transmitter integrates tangential turbine technology with
hermetically sealed circuitry to provide accurate flow measurement and control in the
harshest environments. The 2-wire loop-powered design transmits a 4 to 20 mA signal
proportional to flow rate. Models can accurately measure flow in both directions and can
be mounted in any orientation. Model SF11 has a clear polycarbonate viewing cover for
visible indication of flow. Units feature LED power indication, adjustable zero and span,
polarity protection and over current limiting.
Model
SF10
SF11
Cover Material
316 SS
Clear Polycarbonate
Series
SF2
3-45/64
[94.06]
1-9/64
[28.97]
2-29/64
[62.31]
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: 316 SS shaft and
case, Iglide® bearings, Buna-N seal
and acetal copolymer, (polycarbonate
cover on Model SF11).
Flow Range: 0.5 to 15 GPM (5.7 to
56.8 LPM).
Accuracy: ±2% FS.
Repeatability: 0.5% full scale.
Temperature Limits: 20 to 225°F
(–7 to 107°C).
Pressure Limits: 500 psig (34 bar)
Model SF10; 200 psig (14 bar) Model
SF11.
Response Time: 2 seconds to 90%
(step change in flow rate).
Supply Voltage: 12 to 35 VDC.
Output: 4 to 20 mA.
Loop Resistance: 1150 ohms max.
Process Connection: 1/2˝ female
NPT.
Electrical Connection: Wire leads:
22 AWG x 9´ (2.7 m).
Max. Particle Size: 100µm.
Agency Approvals: CE.
Iglide® is a registered trademark of Igus GMBH
Sight Flow Meters
FLOW
APPLICATIONS
Ideal for measuring flow rates in cooling and lubrication circuits, HVAC systems,
aggressive chemical metering, and batching systems.
2-5/8
[66.68]
SPDT or Pulse Output, Visual Flow Confirmation, Brass Body
A
2-1/2
[63.5]
SF2-1
Series SF2 Sight Flow Meters combine visual confirmation of flow with a relay or pulse
output. The brass, unibody construction, one piece composite rotor, and ceramic shaft
delivers durability with broader chemical, temperature, and pressure capabilities. For
specific flow setpoint switching, select SF2-1 meters with a SPDT relay output. Setpoints
are fully adjustable over the specified flow range. The dynamic operation of the rotor
guards against jamming and false actuation. For flow rate monitoring or metering
applications, select SF2-2 meters with a pulse output proportional to the rate of flow. The
4.5 to 24 VDC pulse output is compatible with most digital logic families.
SPDT Relay Output
Range (GPM)
Model
SF2-104 0.5 to 5.0
SF2-101 0.5 to 5.0
SF2-114 4.0 to 20.0
SF2-111 4.0 to 20.0
SF2-124 5.0 to 30.0
SF2-121 5.0 to 30.0
SF2-134 8.0 to 60.0
SF2-131 8.0 to 60.0
Pulsed Output
Range (GPM)
Model
SF2-204 0.5 to 5.0
SF2-214 4.0 to 20.0
SF2-224 5.0 to 30.0
SF2-234 8.0 to 60.0
CALL TO ORDER:
Power
24 VDC
110 VAC
24 VDC
110 VAC
24 VDC
110 VAC
24 VDC
110 VAC
Connection
1/4˝ female NPT
1/4˝ female NPT
1/2˝ female NPT
1/2˝ female NPT
3/4˝ female NPT
3/4˝ female NPT
1˝ female NPT
1˝ female NPT
Power
4.5 to 24 VDC
4.5 to 24 VDC
4.5 to 24 VDC
4.5 to 24 VDC
Connection
1/4˝ female NPT
1/2˝ female NPT
3/4˝ female NPT
1˝ female NPT
U.S. Phone 219 879-8000
•
C
SIDE VIEW VAC SWITCH MODELS
SIDE VIEW VDC SWITCH AND
TRANSMITTER MODELS
Dimensions in [mm]
Model
SF2-104
SF2-101
SF2-114
SF2-111
SF2-124
SF2-121
SF2-134
SF2-131
SF2-204
SF2-214
SF2-224
SF2-234
A
B
C
–
4-1/2 [114.3]
3-1/64 [76.6]
7/8 [22.23]
–
4-1/2 [114.3]
–
4-49/64 [121.05]
3-61/64 [100.41]
1-1/16 [26.99]
–
4-49/64 [121.05]
D
2-21/64 [59.13]
–
2-21/64 [59.13]
–
2-61/64 [75]
–
2-61/64 [75]
–
3-1/64 [76.6]
2-21/64 [59.13]
–
3-61/64 [100.41] –
SPECIFICATIONS
Service: Liquids compatible with
wetted parts.
Wetted Materials: Brass body,
ceramic pin, PPS rotor, Polysulfone
lens and fluoroelastomer O-ring.
Accuracy: Relay output: ±5%; Pulsed
output: ±7% for ranges up to 5.0 GPM,
±15% for ranges up to 60.0 GPM.
Temperature Limits: -20 to 212°F (-29
to 100°C).
Pressure Limit: 200 psig (13.8 bar) @
70°F.
Power Requirements: See table.
U.K. Phone (+44) (0)1494-461707
•
13/16 [20.64]
1-1/16 [26.99] 2-61/64 [75]
Output: SPDT: 1 Amp, 24 VDC
resistive; 0.3 Amp, 110 VAC or 4.5
VDC to 24 VDC pulse depending on
model.
Electrical Connections: Relay output
models: 20AWG PVC-jacketed, 24˝
cable; Pulsed output models: 22AWG
PVC-jacketed, 24˝ cable.
Process Connections: See table.
Setpoint Differential: 15% max for
relay output models.
Maximum Viscosity: 200 SSU.
Agency Approvals: CE.
Australia Phone (+61) (0) 2 4272 2055
217
Flow Transmitters,
Paddlewheel
41/64
[16.27]
SF2-2
D
B
C
218:Layout 2
7/13/11
3:13 PM
Page 1
Series
SFI-800
Sight Flow Indicator/Transmitter
Low Cost, Optional Output for Flow Rate and Totalization
UV Stabilized Polycarbonate Model
1-15/32
17/32 [37.30]
[13.50]
SFI-801
2-15/16
[74.61]
(4) 1/4 DIA [6.35]
HOLE ON 2-1/2 DIA [63.5]
BOLT CIRCLE
1-3/32
[27.78]
REMOVAL
CLEARANCE
2-1/4 [57.15]
2-1/32
[51.59]
SFI-800
PANEL MOUNT
(4) 13/64 DIA [5.16]
CUTOUT
HOLE ON 2-1/2 DIA [63.5]
BOLT CIRCLE
2-1/2
[63.50]
2-13/16
[71.44]
SFI WITH
A-711 OPTION
1/2 OR
3/4 NPT2
[50.80]
2-5/16
[58.74]
SFI MODEL ONLY
FLOW
The Series SFI-800 Sight Flow Indicator is a low cost, durable rotor style flow
indicator with optional Hall effect magnetic output packages for remote flow monitoring.
Both SFI-800 and 801 models are constructed of clear plastic enabling 360° viewing of the
spinning rotor for easy flow indication. SFI-800 models are constructed of polysulfone with
excellent chemical compatibility, high pressure and temperature ratings, and all wetted
materials are FDA/NSF ratable for potable water applications. SFI-801 models are
constructed of UV stabilized polycarbonate making them ideal for outdoor applications
(materials do not meet FDA/NSF). The SFI-801 models also feature an easy view bright
red impeller.
Flow Transmitters,
Paddlewheel
SFI with A-711 Option
Body and Sensors Attached:
To order A-711 attached to flow indicator body add suffix -A711 to the body part
number.
Example: SFI-800-1/2-A711
SPECIFICATIONS
Service: Compatible fluids.
Wetted Materials
Body: SFI-800: Polysulfone; SFI-801: UV stabilized polycarbonate;
Window: SFI-800: Polysulfone; SFI-801: UV stabilized polycarbonate;
Rotor: SFI-800: White polysulfone; SFI-801: Red UV stabilized PBT;
Rotor Pin: 316 SS;
Thrust washers: 300 Series SS;
O-ring: SFI-800: Fluoroelastomer (NSF grade); SFI-801: Buna-N.
Temperature Limits: SFI-800: -20 to 212°F (-29 to 100°C); SFI-801: -20 to 130°F
(-29 to 55°C).
Pressure Limits: SFI-800: 150 psi (10.34 bar); SFI-801: 125 psi (8.62 bar).
Viscosity Max: 200 SSU.
Weight: SFI-800: 3.35 oz (95 g); SFI-800-A711: 5.0 oz (142 g).
ELECTRICAL SPECIFICATIONS (for A-711 Option Only)
Temperature Limits: -20 to 212°F (-29 to 100°C).
Power Requirements: 8 to 28 VDC.
Output Signal: White lead: 5 VDC; Green lead: 8 to 28 VDC equal to supply
voltage. Pulsed output with frequency rate proportional to flow rate.
Accuracy: ±5% of F.S.
Frequency Output Range: 0 to 100 Hz.
Electrical Connections: Black lead - ground; White lead: 5 VDC out pulse; Green
lead: 8 to 28 VDC out pulse; Red lead: 8 to 28 VDC supply.
To order A-712 attached to flow indicator body add suffix -A712 to the body part
number.
Example: SFI-800-1/2-A712
To order A-713 attached to flow indicator body add suffix -A713 to the body part
number.
Example: SFI-800-1/2-A713
ELECTRICAL SPECIFICATIONS (for A-712 option only)
Temperature Limits: -20 to 212°F (-29 to 100°C).
Power Requirements: 15 to 28 VDC.
Output Signal: White lead: 1 to 10 VDC.
Accuracy: ±5% of F.S.
Electrical Termination: Black lead: Ground; Red lead: 15 to 28 VDC input; White
lead: 1 to 10 VDC output.
SENSOR ONLY
Model
A-711
A-712
A-713
Description
Pulsed Output
1 to 10 VDC
Two Open Collectors
*Sensor only, not attached to the flow indicator body.
ELECTRICAL SPECIFICATIONS ( for A-713 option only)
Temperature Limits: -20 to 212°F (-29 to 100°C).
Power Requirements: 8 to 28 VDC.
Output Signal: White lead: Normally open switch; Green lead: Normally closed
switch. Both open collector, 100 mA max, 28 VDC max.
Electrical Connections: Black lead: Ground; White lead: Normally open; Green
lead: Normally closed; Red lead: 8 to 28 VDC.
BODY ONLY
Model
Description
Polysulfone Body
SFI-800-1/2
Indicator Only
SFI-800-3/4
Indicator Only
SFI-800-1/2-LF Indicator Only
Polycarbonate Body
SFI-801-1/2
Indicator Only
SFI-801-3/4
Indicator Only
SFI-801-1/2-LF Indicator Only
218
Range GPM (LPM)
Connection Female NPT
2-20 (7.6-75.5)
3-35 (11.4-132.5)
0.5-6.5 (1.9-24.6)
1/2˝
3/4˝
1/2˝
2-20 (7.6-75.5)
3-35 (11.4-132.5)
0.5-6.5 (1.9-24.6)
1/2˝
3/4˝
1/2˝
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
219:Layout 2
7/13/11
3:14 PM
Page 1
Series
SFI-100T
Sight Flow Indicator/Transmitter
Output for Flow Rate and Totalization
4
[101.60]
2
[50.80]
3
[76.20]
1-3/8
[34.93]
Description
Model
SFI-100T-1/2-A711T Brass Indicator
with A-711T Sensor
SFI-100T-3/4-A711T Brass Indicator
with A-711T Sensor
A-711T
Output Sensor Package
Range GPM
(LPM)
2-20
(7.6-75.5)
3-35
(11.4-132.5)
–
3/4˝
–
ELECTRICAL SPECIFICATIONS
Temperature Limits: -20 to 212°F (-29 to 100°C).
Power Requirements: 8 to 28 VDC.
Output Signal: White lead: 5 VDC. Green lead: 8 to 28 VDC equal to supply
voltage. Pulsed output with frequency rate proportional to flow rate.
Accuracy: ±5% of F.S.
Frequency Output Range: 0 to 100 Hz.
Electrical Connections: Black lead: Ground; White lead: 5 VDC out pulse; Green
lead: 8 to 28 VDC out pulse; Red lead: 8 to 28 VDC supply.
Flow Transmitters,
Paddlewheel
Series
TTM
Connection
Female NPT
1/2˝
SPECIFICATIONS
Service: Compatible fluids.
Wetted Materials: Body: Brass; Window: Tempered glass; Rotor: Red UV
stabilized PBT; Rotor pin: 316 SS; Thrust washers: 300 series SS; Gasket: Buna-N.
Temperature Limits: -20 to 200°F (-29 to 93°C).
Pressure Limits: 125 psi (8.62 bar).
Viscosity Max: 200 SSU.
Weight: SFI only: 1.5 lb (0.7 kg); with A-711T: 1.8 lb (0.8 kg).
Electronic Totalizing Meter
Batch or Cumulative Totals, Easy-to-Read LCD Display, ±5% Accuracy
4-1/8
[104.7]
2-1/2
[63.50]
2-9/64
[54.37]
1˝ NPT
Measure batch and cumulative totals in liquid transfer systems with the Series TTM
Electronic Totalizing Meter. The meter is designed for any pump, pressure, or gravity feed
system with a 3 to 30 GPM (10 to 100 LPM) flow range. View batch and cumulative totals
on the large 4-digit LCD display. Batch totals can be reset to measure flow during a single
use. The cumulative total will automatically reset to zero when a maximum reading of 9999
is obtained. Models designed for use in water applications are constructed of nylon and
rated to 150 psig (10.3 bar). Aluminum models are calibrated for fuels and rated to 300 psig
(20.7 bar).
Model
TTM10
TTM11
TTM20
TTM21
Application
Water*
Water*
Fuels†
Fuels†
Body Material
Nylon
Nylon
Aluminum
Aluminum
Units
Gallons
Liters
Gallons
Liters
*Calibrated for use with water
†Calibrated for use with gasoline, diesel fuel and kerosene
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Service: Compatible liquids.
Flow Range: 3 to 30 GPM (10 to 100
LPM).
Wetted Materials: Bearings: Ceramic;
Shaft: Tungsten carbide; Rotor: Nylon
6-6; Rings: 316 SS; Body: TTM10, 11:
Nylon 6-6, TTM20, 21: Aluminum;
Other: TTM20, 21: Ceramic magnet.
Accuracy: ±5%.
Batch Total Maximum: 9999.
Cumulative Total Maximum: 9999.
Temperature Limits: 14 to 130°F (-10
to 54°C).
Pressure Limits: Nylon models: 150
psig (10 bar); Aluminum models: 300
psig (20 bar).
U.K. Phone (+44) (0)1494-461707
•
FLOW
The SFI-100T is a low cost and durable flow transmitter that combines our popular
100 Series Sight Flow indicator with our A-711T output sensor. The SFI-100T sight flow
indicator is constructed of a robust, solid brass body and a tempered glass window. A bright
red impeller is featured for great visual indication of flow through the window. The front
window can be easily unscrewed to clean out the sight flow indicator. Ideal for outdoor
applications, the flow transmitter is weatherproof and unaffected by UV light.
The A-711T output sensor has a VDC output with pulsing for flow totalization and a
proportional frequency change for flow rate. For added versatility there are two output
choices of 5 VDC or a VDC equal to the input power supplied. The output is compatible with
digital rate meters/totalizers and other electronic systems. Great for use in monitoring
water flow especially in chillers.
3/4 NPT
2 PLCS
Pressure Drop: 2 psi (0.14 bar) @ 30
GPM (100 LPM).
Maximum Particulate Size: 350
microns.
Display: 4-digit LCD, 5/8˝ H.
Auto Shut-off: After 1 minute.
Connections: 1˝ female NPT.
Power: Two AAA alkaline batteries
(included).
Battery Life: Approx. 9000 hours.
Weight: Nylon models: 0.4 lb
(190 g); Aluminum models: 0.7 lb
(340 g).
Agency Approvals: CE.
Australia Phone (+61) (0) 2 4272 2055
219
220:Layout 2
7/13/11
3:14 PM
Page 1
Series
PFT
Paddlewheel Flow Sensor
Non-Magnetic Sensing, Insertion Style for 1-1/2 to 40˝ Pipe
1/2˝ NPT
Ø2-1/2
[63.50]
7-29/32
[200.94]
3-13/16
[96.84]
2-25/64
[60.72]
1-1/2˝ NPT
FLOW
2˝ HEX
[50.80]
SPECIFICATIONS
Service: Water-based fluids.
Range: 1.2 to 25 ft/s (0.37 to 7.62 m/s).
Wetted Materials: Body and fitting: Brass or 316 SS; fitting o-ring: FKM standard,
silicone or Buna-N optional; impeller: 316 SS; shaft: Tungsten carbide standard or
316 SS optional; bearing: PTFE standard, carbon graphite optional.
Linearity: ±1.0% of full range.
Repeatability: ±0.5% of full range.
Temperature Limits: -40 to 212°F (-40 to 100°C).
Pressure Limits: 400 psig (27.6 bar) @ 100°F (37.8°C), 325 psig (22.4 bar) @
212°F (100°C).
Process Connection: 1-1/2˝ NPT male standard, 2˝ NPT male optional.
Output: NPN open collector with square wave output, rated 60V @ 50 mA
maximum.
Frequency: 3.2 to 200 Hz;
Pulse width: 2.5 msec ±25%.
Power Requirement: 10 to 35 VDC.
Power Consumption: 40 mA (max).
Electrical Connection: 22 AWG shielded UL type PTLC rated 105°C, 20´ (6.1 m)
long with cable gland. Can be extended up to 2000´ (609 m) with similar cable.
Optional UL listed burial rated cable.
Enclosure Rating: NEMA 6P (IP67).
Housing Materials: Brass or 316 SS.
Weight: 3 lb.
Agency Approvals: CE.
The Series PFT is a paddlewheel flow sensor used to monitor liquid flow rates in pipes
from 1-1/2 to 40˝ with just one size adjustable sensor. A square wave output signal is
generated with frequency proportional to flow velocity. Multiple wetted material choices
offer application versatility. The PFT is ideal for monitoring water flow rates in irrigation
systems and building automation cooling systems.
The PFT uses inductive sensing to sense the blades of the impeller as they rotate. Sensor
technology does not use magnets allowing low flow rate monitoring and no concerns with
magnetic material in the flow. Paddlewheel, shaft and bearings are easily field replaceable.
Flow Transmitters,
Paddlewheel
FEATURES
• Bearings and shaft offer excellent wear protection even in applications with
particulate for long life
• Weatherproof and submersible rated for irrigation applications
APPLICATIONS
• Irrigation, ground water remediation, cooling systems, pump protection, leak
detection, filtration systems
Model
PFT-IDN-B111-S
PFT-IDN-S111-S
Description
Brass body, FKM o-ring, 316 SS impeller, tungsten
carbide shaft, PTFE bearing, 1-1/2˝ NPT male
connection, 20´ of cable
316 SS body, FKM o-ring, 316 SS impeller, tungsten
carbide shaft, PTFE bearing, 1-1/2˝ NPT male
connection, 20´ of cable
Consult factory for longer cable lengths, burial rated cable, 2˝ NPT connection, or
other wetted materials.
220
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
221:Layout 2
7/13/11
3:15 PM
Page 1
Series
TFM-LP
Liquid Turbine Flow Meter
316SS Body, 0 to 5 VDC and Pulse Outputs
29/64
[11.43]
TRIMPOT
ADJUSTMENT
OPENING
1-15/32
[37.21]
2XØ1/8 THRU
Ø.3/16 1/8
Series TFM-LP Liquid Turbine Flow Meters are suitable for a wide variety of
industrial, commercial, and laboratory flow applications. These meters utilize a turbine
wheel and electro-optical detection to convert flow rates into a linear 0 to 5 VDC output
signal for recording and data logging. Couple this unit with a Series TM2 Flow Totalizer
for a remote flow monitoring display. A power adapter or mating cable assembly is required
for operation.
˝A˝ (in)
3-27/64
3-53/64
3-53/64
3-53/64
3-53/64
4-1/8
4-1/8
Connection
1/8˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
3/8˝ OD
3/8˝ OD
ACCESSORIES
Description
Model
115 VAC Power Adapter and Signal Cable
A-454
230 VAC Power Adapter and Signal Cable
A-455
36˝ Mating Cable with Spliced Leads
A-456
Series
TFM-LI
STAINLESS
STEEL
FITTINGS
1-1/32
[26.04]
SPECIFICATIONS
Service: Clean liquids compatible with wetted materials.
Wetted Materials: 316 SS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy: ±1% of full scale.
Linearity: ±1% of full scale.
Repeatability: ±0.2% of full scale.
Temperature Limits: 41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C);
Sensitivity: ±0.2% of full scale per °C.
Pressure Limits: 500 psig (34.5 bar).
Process Connection: Compression fitting, see model table.
Power Requirements: 11.5 to 15 VDC.
Power Consumption: 35 mA @ 12 VDC.
Output Signal: 0 to 5 VDC: Minimum 2.5 kΩ load; Pulse: 7.5 VDC peak buffered
square wave.
Electrical Connections: Four-pin power and signal connector. A power adapter or
mating cable required for operation. See Accessories Table.
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.86 lb (390 g).
Agency Approvals: CE.
316SS Body, 0 to 5 VDC Output, LCD Indication
TRIMPOT ADJUSTMENT
OPENING
1-47/64
[44.09]
BLACK STAINLESS
TRIM LCD STEEL
DISPLAY FITTINGS
2X 1 [25.40]
29/64
[11.43]
“A”
2XØ.125 THRU
Ø.188 THRU
19/32
[15.17]
2-1/32
[51.69]
Series TFM-LI Liquid Turbine Flow Meters are suitable for a wide variety of
industrial, commercial, and laboratory flow applications. These meters utilize a turbine
wheel and electro-optical detection to convert flow rates into a linear 0 to 5 VDC output
signal for recording and data logging. A 3-1/2 digit LCD informs the user of the actual flow
rate. A power adapter or mating cable assembly is required for operation.
Model
TFM-LI03
TFM-LI04
TFM-LI05
TFM-LI06
TFM-LI07
TFM-LI08
TFM-LI09
Range
.21 to 1.6 GPH (.0013 to .1 LPM)
.32 to 3.2 GPH (.02 to .2 LPM)
.79 to 7.9 GPH (.05 to .5 LPM)
1.6 to 16 GPH (0.1 to 1 LPM)
3.2 to 32 GPH (.2 to 2 LPM)
7.9 to 79 GPH (.5 to 5 LPM)
16 to 160 GPH (1 to 10 LPM)
Connection
1/8˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
3/8˝ OD
3/8˝ OD
˝A˝ (in)
3-9/16
3-41/64
3-41/64
3-41/64
3-41/64
3-27/32
3-27/32
ACCESSORIES
Description
Model
115 VAC Power Adapter and Signal Cable
A-454
230 VAC Power Adapter and Signal Cable
A-455
36˝ Mating Cable with Spliced Leads
A-456
CALL TO ORDER:
U.S. Phone 219 879-8000
•
19/64
[7.59]
2-63/64
[75.69]
2X 17/32
[13.46]
2-21/64
[59.28]
61/64
[24.10]
1-19/32
[40.64]
SPECIFICATIONS
Service: Clean liquids compatible with wetted materials.
Wetted Materials: 316 SS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy: ±1% of full scale.
Linearity: ±1% of full scale.
Repeatability: ±0.2% of full scale.
Temperature Limits: 41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C);
Sensitivity: ±0.2% of full scale per °C.
Pressure Limits: 500 psig (34.5 bar).
Process Connection: Compression fitting, see model table.
Power Requirements: 11.5 to 15 VDC.
Power Consumption: 35 mA @ 12 VDC.
Output Signal: 0 to 5 VDC: Minimum 2.5 kΩ load.
Electrical Connections: Four-pin power and signal connector. A power adapter or
mating cable required for operation. See Accessories Table.
Display: LCD, 0.39˝ (10 mm) digits (only in LPM).
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.80 lb (380 g).
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
221
Flow Transmitters,
Turbine
Liquid Turbine Flow Meter
FLOW
Range
.21 to 1.6 GPH (.0013 to .1 LPM)
.32 to 3.2 GPH (.02 to .2 LPM)
.79 to 7.9 GPH (.05 to .5 LPM)
1.6 to 16 GPH (0.1 to 1 LPM)
3.2 to 32 GPH (.2 to 2 LPM)
7.9 to 79 GPH (.5 to 5 LPM)
16 to 160 GPH (1 to 10 LPM)
“A”
2X 17/32 2-1/32
[13.34] [51.69]
CABLE
CONNECTION
Model
TFM-LP03
TFM-LP04
TFM-LP05
TFM-LP06
TFM-LP07
TFM-LP08
TFM-LP09
51/64
[20.32]
222:Layout 2
7/13/11
3:15 PM
Page 1
Series
TFP-GV
Gas Turbine Flow Meter
PPS Body, 0 to 5 VDC Output
2-21/64
[59.31] 33/64
1-35/64
“A”
[13.21] 2XØ 136 THRU [39.37]
15/16
[23.74]
TRIMPOT
1/4
ADJUSTMENT 2-1/32
[6.35]
[51.69]
OPENING
19/64
[7.62]
2xØ.136 THRU
ACETAL
FITTINGS
“A”
ACETAL
FITTINGS
3/5/16
[84.07]
4-61/64
[125.73]
1-41/64
[41.53]
29/32
[22.99]
29/32
[22.86]
1/2
[12.70]
3-3/64
[77.47]
1-1/4 2-5/32
[31.75] [54.61]
High Flow Configuration
FLOW
Series TFP-GV Gas Turbine Flow Meters are suitable for a wide variety of industrial,
commercial, and laboratory flow applications. These meters utilize a turbine wheel and
electro-optical detection to convert flow rates into a linear 0 to 5 VDC output signal for
recording and data logging. Couple this unit with a Series FIV Flow Totalizer for a remote
flow monitoring display. A power adapter or mating cable assembly is required for
operation.
Model
TFP-GV03
TFP-GV04
TFP-GV05
TFP-GV06
TFP-GV07
TFP-GV08
TFP-GV09
TFP-GV10*
TFP-GV11*
TFP-GV12*
TFP-GV13*
Range
.042 to .21 SCFH (.02 to .1 LPM)
.085 to .42 SCFH (.04 to .2 LPM)
.21 to 1.1 SCFH (.1 to .5 LPM)
.42 to 2.1 SCFH (.2 to 1 LPM)
.85 to 4.2 SCFH (.4 to 2 LPM)
2.1 to 11 SCFH (1 to 5 LPM)
4.2 to 21 SCFH (2 to 10 LPM)
8.5 to 42 SCFH (4 to 20 LPM)
21 to 110 SCFH (10 to 50 LPM)
42 to 210 SCFH (20 to 100 LPM)
85 to 420 SCFH (40 to 200 LPM)
SPECIFICATIONS
Service: Clean dry gases compatible
with wetted materials.
Wetted Materials: PPS, acetal,
sapphire, glass, epoxy, and
fluoroelastomer.
Accuracy: ±3% of full scale.
Linearity: ±3% of full scale.
Repeatability: ±0.5% of full scale.
Temperature Limits: 41 to 131°F
(5 to 55°C); Storage: 32 to 158°F (0 to
70°C); Sensitivity: ±0.2% of full scale
per °C.
Pressure Limits: 40 psig (2.8 bar).
˝A˝ (in)
3-27/64
3-27/64
3-27/64
3-27/64
3-13/16
3-13/16
3-13/16
7-7/64
7-7/64
7-1/2
7-1/2
Connection
1/8˝ OD
1/8˝ OD
1/8˝ OD
1/8˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
3/8˝ OD
3/8˝ OD
1/2˝ OD
1/2˝ OD
Process Connection: Compression
fitting, see model table.
Power Requirements: 11.5 to 15
VDC.
Power Consumption: 35 mA @ 12
VDC.
Output Signal: 0 to 5 VDC: Minimum
2.5 kΩ load.
Electrical Connections: Four-pin
power and signal connector. A power
adapter or mating cable required for
operation. See Accessories Table.
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.16 lb (75 g).
Agency Approvals: CE.
ACCESSORIES
Model
A-454
A-455
A-456
Description
115 VAC Power Adapter and Signal Cable
230 VAC Power Adapter and Signal Cable
36˝ Mating Cable with Spliced Leads
Flow Transmitters,
Turbine
* These modes come in high flow configuration
Series
TFP-GI
Gas Turbine Flow Meter
PPS Body, 0 to 5 VDC Output, LCD Indication
19/64
[7.62]
3-1/16
2-1/32 [77.72]
[51.69]
2xØ.136 THRU
Range
.042 to .21 SCFH (.02 to .1 LPM)
.085 to .42 SCFH (.04 to .2 LPM)
.21 to 1.1 SCFH (.1 to .5 LPM)
.42 to 2.1 SCFH (.2 to 1 LPM)
.85 to 4.2 SCFH (.4 to 2 LPM)
2.1 to 11 SCFH (1 to 5 LPM)
Connection
1/8˝ OD
1/8˝ OD
1/8˝ OD
1/8˝ OD
1/4˝ OD
1/4˝ OD
VISIT OUR WEBSITES:
˝A˝ (in)
3-27/64
3-27/64
3-27/64
3-27/64
3-13/16
3-13/16
www.dwyer-inst.com
1/4
[6.35]
“A”
ACCESSORIES
Model
Description
A-454
115 VAC Power Adapter and Signal Cable
A-455
230 VAC Power Adapter and Signal Cable
A-456
36˝ Mating Cable with Spliced Leads
222
TRIMPOT
ADJUSTMENT
OPENING
SPECIFICATIONS
Service: Clean dry gases compatible with wetted materials.
Wetted Materials: PPS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy: ±3% of full scale.
Linearity: ±3% of full scale.
Repeatability: ±0.5% of full scale.
Temperature Limits: 41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C);
Sensitivity: ±0.2% of full scale per °C.
Pressure Limits: 40 psig (2.8 bar).
Process Connection: Compression fitting, see model table.
Power Requirements: 11.5 to 15 VDC.
Power Consumption: 35 mA @ 12 VDC.
Output Signal: 0 to 5 VDC: Minimum 2.5 kΩ load.
Electrical Connections: Four-pin power and signal connector. A power adapter or
mating cable required for operation. See Accessories Table.
Display: LCD, 0.39˝ (10 mm) digits (only in LPM).
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.23 lb (101 g).
Agency Approvals: CE.
Series TFP-GI Gas Turbine Flow Meters are suitable for a wide variety of industrial,
commercial, and laboratory flow applications. These meters utilize a turbine wheel and
electro-optical detection to convert flow rates into a linear 0 to 5 VDC output signal for
recording and data logging. A 3-1/2 digit LCD informs the user of the actual flow rate. A
power adapter or mating cable assembly is required for operation.
Model
TFP-GI03
TFP-GI04
TFP-GI05
TFP-GI06
TFP-GI07
TFP-GI08
CABLE
CONNECTION
ACETAL
FITTINGS
33/64
[13.21]
BLACK
TRIM LCD
DISPLAY
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
223:Layout 2
7/13/11
3:16 PM
Page 1
Series
TFP-LP
Liquid Turbine Flow Meter
PPS Body, 0 to 5 VDC and Pulse Outputs
2-21/64
[59.31]
15/16
[23.74]
CABLE CONNECTION
Series TFP-LP Liquid Turbine Flow Meters are suitable for a wide variety of
industrial, commercial, and laboratory flow applications. These meters utilize a turbine
wheel and electro-optical detection to convert flow rates into a linear 0 to 5 VDC output
signal for recording and data logging. Couple this unit with a Series TM2 Flow Totalizer
for a remote flow monitoring display. A power adapter or mating cable assembly is required
for operation.
Range
.21 to 1.6 GPH (.0013 to .1 LPM)
.32 to 3.2 GPH (.02 to .2 LPM)
.79 to 7.9 GPH (.05 to .5 LPM)
1.6 to 16 GPH (0.1 to 1 LPM)
3.2 to 32 GPH (.2 to 2 LPM)
7.9 to 79 GPH (.5 to 5 LPM)
16 to 160 GPH (1 to 10 LPM)
“A” (in)
3-9/16
3-41/64
3-41/64
3-41/64
3-41/64
3-27/32
3-27/32
Connection
1/8˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
3/8˝ OD
3/8˝ OD
ACCESSORIES
Description
Model
115 VAC Power Adapter and Signal Cable
A-454
230 VAC Power Adapter and Signal Cable
A-455
36˝ Mating Cable with Spliced Leads
A-456
2XØ9/64 THRU
SPECIFICATIONS
Service: Clean liquids compatible with wetted materials.
Wetted Materials: PPS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy: ±1% of full scale.
Linearity: ±1% of full scale.
Repeatability: ±0.2% of full scale.
Temperature Limits: 41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C);
Sensitivity: ±0.2% of full scale per °C.
Pressure Limits: 100 psig (6.8 bar).
Process Connection: Compression fitting, see model table.
Power Requirements: 11.5 to 15 VDC.
Power Consumption: 35 mA @ 12 VDC.
Output Signal: 0 to 5 VDC: Minimum 2.5 kΩ load; Pulse: 7.5 VDC peak buffered
square wave.
Electrical Connections: Four-pin power and signal connector. A power adapter or
mating cable required for operation. See Accessories Table.
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.19 lb (85 g).
Agency Approvals: CE.
Liquid Turbine Flow Meter
PPS Body, 0 to 5 VDC Output, LCD Indication
BLACK TRIM
LCD DISPLAY
CABLE
CONNECTION
ACETAL
FITTINGS
33/64
[13.21]
19/64
[7.62]
2-1/32
[51.69]
2XØ.136 THRU
Series TFP-LI Liquid Turbine Flow Meters are suitable for a wide variety of industrial,
commercial, and laboratory flow applications. These meters utilize a turbine wheel and
electro-optical detection to convert flow rates into a linear 0 to 5 VDC output signal for
recording and data logging. A 3-1/2 digit LCD informs the user of the actual flow rate. A
power adapter or mating cable assembly is required for operation.
Model
TFP-LI03
TFP-LI04
TFP-LI05
TFP-LI06
TFP-LI07
TFP-LI08
TFP-LI09
Range
.21 to 1.6 GPH (.0013 to .1 LPM)
.32 to 3.2 GPH (.02 to .2 LPM)
.79 to 7.9 GPH (.05 to .5 LPM)
1.6 to 16 GPH (0.1 to 1 LPM)
3.2 to 32 GPH (.2 to 2 LPM)
7.9 to 79 GPH (.5 to 5 LPM)
16 to 160 GPH (1 to 10 LPM)
“A” (in)
3-27/64
3-13/16
3-13/16
3-13/16
3-13/16
4-1/8
4-1/8
Connection
1/8˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
1/4˝ OD
3/8˝ OD
3/8˝ OD
ACCESSORIES
Model
A-454
A-455
A-456
Description
115 VAC Power Adapter and Signal Cable
230 VAC Power Adapter and Signal Cable
36˝ Mating Cable with Spliced Leads
CALL TO ORDER:
U.S. Phone 219 879-8000
•
3-1/16
[77.72]
TRIMPOT
ADJUSTMENT
OPENING
1/4
[6.35]
“A”
SPECIFICATIONS
Service: Clean liquids compatible with wetted materials.
Wetted Materials: PPS, acetal, sapphire, glass, epoxy, and fluoroelastomer.
Accuracy: ±1% of full scale.
Linearity: ±1% of full scale.
Repeatability: ±0.2% of full scale.
Temperature Limits: 41 to 131°F (5 to 55°C); Storage: 32 to 158°F (0 to 70°C);
Sensitivity: ±0.2% of full scale per °C.
Pressure Limits: 100 psig (6.8 bar).
Process Connection: Compression fitting, see model table.
Power Requirements: 11.5 to 15 VDC.
Power Consumption: 35 mA @ 12 VDC.
Output Signal: 0 to 5 VDC: Minimum 2.5 kΩ load.
Electrical Connections: Four-pin power and signal connector. A power adapter or
mating cable required for operation. See Accessories Table.
Display: LCD, 0.39˝ (10 mm) digits (only in LPM).
Enclosure Rating: IP10 (NEMA 1).
Weight: 0.27 lb (121 g).
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
223
Flow Transmitters,
Turbine
Series
TFP-LI
19/64
[7.62]
ACETAL
FITTINGS
FLOW
Model
TFP-LP03
TFP-LP04
TFP-LP05
TFP-LP06
TFP-LP07
TFP-LP08
TFP-LP09
“A”
1-35/64
[39.37]
TRIMPOT
ADJUSTMENT
OPENING 2-1/32
[51.69]
33/64
[13.21]
1/4
[6.35]
224:Layout 2
7/13/11
3:16 PM
Page 1
Series
WM
Multi-Jet Water Meter
Economical, Bronze Body, Dry Dial
TAMPER PROOF
SEAL
SPUD
H
FILTER ON
INLET
W
L
Flowmeters,
Totalizing
FLOW
Size (S)
in [mm]
5/8 [15]
5/8 x 3/4 [15 x 20]
3/4 [20]
1 [25]
1-1/4 [32]
1-1/2 [40]
2 [50]
Spud
NPSM [BSPP]
3/4 [3/4]
1 [1]
1 [1]
1-1/4 [1-1/4]
1-1/2 [1-1/2]
2 [2]
2-1/2 [2-1/2]
The Series WM Multi-Jet Water Meters are ideal for commercial
and industrial applications. The multi-jet design allows simplicity and
accuracy with wide flow ranges, even in low flow applications. The
magnetically driven, hermetically sealed register will not leak or fog
and is completely separated from the water. These water meters are
designed for long service life and maintenance-free operation.
Length (L)
in [mm]
6-1/2 [165]
7-11/16 [195]
7-11/16 [195]
10-1/4 [260]
10-1/4 [260]
11-13/16 [300]
11-13/16 [300]
Width (W)
in [mm]
3-15/16 [99]
3-15/16 [99]
3-15/16 [99]
4-1/16 [103]
4-1/8 [104]
4-7/8 [124]
4-15/16 [125]
Height (H)
in [mm]
4-1/8 [104]
4-3/16 [106]
4-3/16 [106]
4-1/2 [114]
4-5/8 [117]
5-13/16 [147]
6-3/4 [172]
SPECIFICATIONS
Service: Water.
Flow Range: See model chart.
Wetted Materials: Body: Brass, nylon, acetal; Couplings:
Brass; Measuring chamber: Fluorocarbon (FKM), polyethylene,
high impact polystyrene, ABS plastic.
Accuracy: Transitional flow: ±5%; Nominal flow: ±2% (see
instruction manual).
Temperature Limit: 104°F (40°C).
Pressure Limit: 145 psi (10 bar).
Pressure Drop: See instruction manual.
Totalizing Display Maximum: 9,999,999 counts.
Mounting Orientation: Horizontal.
Weight: See dimension chart.
FEATURES
• Magnetic drive - water is sealed from entering register
• Dry dial won't discolor or fade - hermetically sealed from the
elements
• Integral strainer that protects meters from particulate damage
• Pointer-roller indicator
• Frost resistant body
• Includes two mounting adapters (couplings)
Model
WM-A-C-01
WM-A-C-02
WM-A-C-03
WM-A-C-04
WM-A-C-06
WM-A-C-07
Size
5/8˝
5/8˝ x 3/4˝
3/4˝
1˝
1-1/2˝
2˝
Coupling Size
1/2˝ NPT
3/4˝ NPT
3/4˝ NPT
1˝ NPT
1-1/2 NPT
2˝ NPT
Transitional Flow (GPM)
0.125
0.125
0.25
0.375
1.0
1.25
Nominal Flow (GPM)
0.5-13
1-20
1-22
1.25-30
3-88
5-132
Max Flow (GPM)
13Flow (GPM)
Max
13 20
20 22
22 30
88
132
Model
WM-B-C-08
WM-B-C-10
WM-B-C-11
WM-B-C-12
WM-B-C-13
WM-B-C-14
Size
15 mm
20 mm
25 mm
32 mm
40 mm
50 mm
Coupling Size
1/2˝ BSPT
3/4˝ BSPT
1˝ BSPT
1-1/4˝ BSPT
1-1/2˝ BSPT
2˝ BSPT
Transitional Flow (L/h)
30
50
70
120
200
300
Nominal Flow (m3/h)
0.12-3.0
0.2-5.0
0.28-5
0.48-12
0.8-20
1.2-30
Max Flow (m3/h)
3
5
7
12
20
30
Note: Transition flow accuracy (±5%) GPM (L/h). Nominal flow accuracy (±2%) GPM (M3/h)
224
VISIT OUR WEBSITES:
www.dwyer-inst.com
Weight
lb [kg]
3.09 [1.4]
3.53 [1.6]
3.53 [1.6]
5.73 [2.6]
6.17 [2.8]
11.24 [5.1]
18.74 [8.5]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
225:Layout 2
7/13/11
3:19 PM
Page 1
Series
WMT
Multi-Jet Water Meter/Pulsed Output
Economical, Bronze Body, Dry Dial
TAMPER PROOF
SEAL
S
H
FILTER ON
INLET
W
L
Size (S)
in [mm]
5/8 [15]
5/8 x 3/4 [15 x 20]
3/4 [20]
1 [25]
1-1/4 [32]
1-1/2 [40]
2 [50]
Width (W)
in [mm]
3-15/16 [99]
3-15/16 [99]
3-15/16 [99]
4-1/16 [103]
4-1/8 [104]
4-7/8 [124]
4-15/16 [125]
Height (H)
in [mm]
4-1/8 [104]
4-3/16 [106]
4-3/16 [106]
4-1/2 [114]
4-5/8 [117]
5-13/16 [147]
6-3/4 [172]
Weight
lb [kg]
3.09 [1.4]
3.53 [1.6]
3.53 [1.6]
5.73 [2.6]
6.17 [2.8]
11.24 [5.1]
18.74 [8.5]
SPECIFICATIONS
Service: Water.
Flow Range: See model chart.
Wetted Materials: Body: Brass, nylon, acetal; Couplings: Brass; Measuring
chamber: Fluorocarbon (FKM), polyethylene, high impact polystyrene, ABS
plastic.
Accuracy: Transitional flow: ±5%; Nominal flow: ±2% (see instruction manual).
Temperature Limit: 104°F (40°C).
Pressure Limit: 145 psi (10 bar).
Pressure Drop: See instruction manual.
Totalizing Display Maximum: 9,999,999 counts.
Output Signal: Pulse output with frequency proportional to flow rate. Pulse
options: 0.1 gal, 1 gal, 10 gal, 100 gal per pulse (1L, 10L, 100L per pulse).
Electrical Rating: 0.01A @ 24VAC/DC.
Electrical Connections: Lead wires, 4.5 feet (1.5 meters) long.
Mounting Orientation: Horizontal.
Weight: See dimension chart.
Model
WMT-A-C-01
WMT-A-C-02
WMT-A-C-03
WMT-A-C-04
WMT-A-C-01-1
WMT-A-C-02-1
WMT-A-C-03-1
WMT-A-C-04-1
WMT-A-C-06-10
WMT-A-C-07-10
WMT-A-C-04-100
WMT-A-C-07-100
Size
5/8˝
5/8˝ x 3/4˝
3/4˝
1˝
5/8˝
5/8˝ x 3/4˝
3/4˝
1˝
1-1/2˝
2˝
1˝
2˝
Coupling Size
1/2˝ NPT
3/4˝ NPT
3/4˝ NPT
1˝ NPT
1/2˝ NPT
3/4˝ NPT
3/4˝ NPT
1˝ NPT
1-1/2˝ NPT
2˝ NPT
1˝ NPT
2˝ NPT
Transitional Flow (GPM)
0.125
0.125
0.25
0.375
0.125
0.125
0.25
0.375
1.0
1.25
0.375
1.25
Nominal Flow (GPM)
0.5-13
1-20
1-22
1.25-30
0.5-13
1-20
1-22
1.25-30
3-88
5-132
1.25-30
5-132
Max Flow (GPM)
13
20
22
30
13
20
22
30
88
132
30
132
Gallons per Pulse
0.1
0.1
0.1
0.1
1
1
1
1
10
10
100
100
Model
WMT-B-C-08-1
WMT-B-C-10-1
WMT-B-C-11-1
WMT-B-C-12-1
WMT-B-C-08-10
WMT-B-C-12-10
WMT-B-C-14-10
WMT-B-C-12-100
WMT-B-C-14-100
Size
15 mm
20 mm
25 mm
32 mm
15 mm
32 mm
50 mm
32 mm
50 mm
Coupling Size
1/2˝ BSPT
3/4˝ BSPT
1˝ BSPT
1-1/4˝ BSPT
1/2˝ BSPT
1-1/4˝ BSPT
2˝ BSPT
1-1/4˝ BSPT
2˝ BSPT
Transitional Flow (L/h)
30
50
70
120
30
120
300
120
300
Nominal Flow (m3/h)
0.12-3.0
0.2-5.0
0.28-5
0.48-12
0.12-3.0
0.48-12
1.2-30
0.48-12
1.2-30
Max Flow (m3/h)
3
5
7
12
3
12
30
12
30
Liters per Pulse
1
1
1
1
10
10
10
100
100
Note: Transition flow accuracy (±5%) GPM (L/h). Nominal flow accuracy (±2%) GPM (M3/h).
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
225
Flowmeters,
Totalizing
FEATURES
• Magnetic drive - water is sealed from entering register
• Dry dial won't discolor or fade - hermetically sealed from the elements
• Integral strainer that protects meters from particulate damage
• Pointer-roller indicator
• Frost resistant body
• Pulsed output
• Includes two mounting adapters (couplings)
Length (L)
in [mm]
6-1/2 [165]
7-11/16 [195]
7-11/16 [195]
10-1/4 [260]
10-1/4 [260]
11-13/16 [300]
11-13/16 [300]
FLOW
The Series WMT Multi-Jet Water Meters are ideal for commercial and industrial
applications. The multi-jet design allows simplicity and accuracy with wide flow ranges,
even in low flow applications. The meter is designed for long service life and relatively
maintenance-free operation, even under adverse conditions. The magnetically driven,
hermetically sealed register will not leak or fog and is completely separated from the water.
The reed switch is activated by a magnet on the dial which is directly proportional to the
flow rate. The output is perfect for remote monitoring of flow rate or flow totalization and
can interface with PLC’s, counters, data loggers, and SCADA systems.
Spud
NPSM [BSPP]
3/4 [3/4]
1 [1]
1 [1]
1-1/4 [1-1/4]
1-1/2 [1-1/2]
2 [2]
2-1/2 [2-1/2]
226:Layout 2
7/13/11
3:21 PM
Page 1
Model
TM2
Flow Totalizer
Pulse Input, 8-digit LCD Display
1-1/4
[28.58]
2-61/64
[75.18]
1-1/2
[38.89]
1-9/16
[40.09]
TR
RST
Recommended Panel Cutout: 2-43/64 [67.87] x 1-19/64 [32.94]
SPECIFICATIONS
Input: 7.5 VDC max. pulse.
Accuracy: ±0.2%.
Input Impedance: 27 k Ω at 3 VDC.
Totalizer Type: Up count.
Rate Indication Type: Frequency.
Count Input Speed: 10 kHz @ 50% duty cycle.
Totalizing Range: 0.0001 to 100.0000 (five position decimal point).
Rate Indication Range: 0.001 to 9999 (five position decimal point).
Update Time: 0.7 seconds.
Display: 8-digit LCD, 7/16" H.
Temperature Limits: 32 to 131°F (0 to 55°C).
Housing Material: ABS X-17.
Power: One 3V lithium battery (included).
Average Battery Life: Approximately 5 years.
Weight: 1 Ib (0.5 kg).
Agency Approvals: CE.
Monitor flow rate or total flow with Model TM2 Flow Totalizer. Unit features a four
digit flow rate display and an eight digit totalizing display with a programmable, five
position decimal point. Easily toggle between rate and total with front-panel push-button.
Use scaling factor to define flow rate in engineering units such as ml/min, l/min, or gal/hr.
Model TM2
FLOW
ACCESSORY
TM25, Replacement 3V lithium battery
Flowmeters,
Totalizing
Series
GFT
Flow
Totalizer
Seven Digit Display, Easy Installation
1-1/4
[31.75]
1-1/4
[31.75]
2-7/8
[71.63]
Series GFT Flow Totalizer is designed to be used with mass flowmeters and mass flow
controllers. The totalizer accepts analog output flow signals of either 0 to 5 VDC or 5 to 10
VDC. Series GFT integrates and accumulates up to 7 digits of direct engineering units for
a given gas and flow rate (standard liters, standard cubic centimeters, etc.). Quickly connect
the GFT-10 to Series GFC and GFM mass flow controllers and meters via the modular jack
(replacing the LCD display) or use the GFT-10C to connect in parallel with the display.
SPECIFICATIONS
Input Analog Range: 0 to 5 or 5 to 10 VDC.
Power Consumption: 10 mA @ 12 VDC, less than 0.125 Watts.
Accuracy: ±0.5% FS.
Temperature Stability: ±100 ppm/°C in the range of 5 to 50°C.
Reset: Momentary tact switch.
Display: 7-digit, 5/16˝ (8mm) H.
Power Supply: Internal lithium battery.
Agency Approvals: CE.
Model GFT-05, accepts 0 to 5 VDC input
Model GFT-10, accepts 0 to 10 VDC input
226
VISIT OUR WEBSITES:
ACCESSORIES
Model GFT-05C, Cable for 0 to 5 VDC models
Model GFT-10C, Cable for 5 to 10 VDC models
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
227:Layout 2
7/13/11
3:21 PM
Page 1
Series
UXF3
Ultrasonic Flowmeter Converter
Excellent Performance and Easy Operation
5-19/32 [142.00]
2-53/64
[72.00]
2-61/64
[75.00]
3/32
[2.50]
25/64 [10.00]
LCD DISPLAY
7-7/8
6-11/16
[200.00]
[170.00]
LED
9-11/64
[233.00]
2-23/32
[69.24]
CABLE GLAND CABLE GLAND
WITH 3/8”
WITH 1/4”
OPENING
OPENING
FEATURES
• High accuracy
• Excellent resistance against aerated flow
• Quick response with high-speed microprocessor
• Multilingual display (English, Japanese, German, French, and Spanish)
• Large type graphic LCD
• Front keypad
Model
UXF3-A0
UXF3-B0
UXF3-A1
UXF3-B1
Power
Supply
100-240 VAC 50/60Hz
20-30 VDC
100-240 VAC 50/60Hz
20-30 VDC
CALL TO ORDER:
SPECIFICATIONS
Service: Liquid flow through which ultrasonic signal can be transmitted
(water, sea water, oil, and fluid of unknown velocity).
Inputs: Sensor cable radio frequency coaxial cable RG-58A/U2.
Range: 0 to ±105 fps (0 to ±32 m/s) (bi-directional flow).
Display: LCD with backlight, 16 letters 2 lines.
Accuracy: ±1.0% of rate.
Power Requirements: 100 to 240 VAC ±10% 50/60 Hz, or 20 to 30
VDC.
Power Consumption: AC: 15 VA; DC: 6W.
Temperature Limits: Ambient –4 to 131°F (-20 to 55°C).
Output: Analog: 4 to 20 mA DC current output; Digital: One mechanical
relay output, 240 VAC, 30 VDC, 1 A. Two transistor outputs available,
Open collector output: 30 VDC, 0.1A.
Serial Communications (option): RS485.
Enclosure Rating: NEMA 4X (IP66).
Material: Aluminum alloy.
Electrical Connections: Screw terminals.
Mounting: Wall or pipe mount.
Weight: 10 lb (4.5 kg).
Serial
Communications
N/A
N/A
RS485
RS485
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
227
Flow Transmitters,
Ultrasonic
The Series UXF3 Ultrasonic Flowmeter Converters are paired with
Series SX1 or SX2 sensors in order to utilize the transit-time measure method.
Thanks to microprocessor-based electronics, the flowmeter can easily be
configured from the front keypad to specific applications. The flowmeter is
suitable for liquid flow measurements for pipes from 1/2 inch to 19.5 feet
diameter. The accuracy of this flowmeter falls within ± 1% of the flow rate. The
UXF3 also provides excellent resistance against aerated flow such as sludge,
raw sewage, and bubble contained flow. The multilingual display supports a
variety of language choices. The combination of the easy to read LCD screen
and front panel buttons along with the variety of language selections makes this
flowmeter very user friendly. This flowmeter incorporates the latest electronics
and high-speed digital signal processing technologies (32 bit MPU), realizing
high performance and easy operation. See bulletin F-107-UXF3 for more details.
FLOW
EARTH TERMINAL
228:Layout 2
7/13/11
3:22 PM
Page 1
Series
SX1
Ultrasonic Flowmeter Detector
Excellent Performance and Easy Operation
NAME PLATE
2-1/8
[54.00]
FRAME
SENSOR
NAME PLATE
SENSOR
1-15/32
[37.00]
16-5/32
[410.16]
15-3/4
[400.00]
SPACING: 0-10-5/8
[270.00]
WIRE ROPE
1-13/16
[46.00]
1-27/32
[46.99]
SX1-B MEDIUM SIZE
NAME PLATE
3-5/8
[92.00]
FLOW
3/16
[5.08]
SX1-B
1-5/16
[33.00]
3-1/16
[78.00]
1-31/32
[50.00]
WIRE ROPE
CHAIN
MOUNTING SPRING
2-5/8
[67.00]
1-13/16
[46.00]
SX1-C LARGE SIZE
FRAME GUIDE
5/16
[8.00]
SX1-A SMALL SIZE
Flow Transmitters,
Ultrasonic
SX1-A
Series SX1 Ultrasonic Flowmeter Detectors are paired with Series UXF1 and UXF3
converters in order to utilize the transit-time measuring method. Two ultrasonic sensors are
mounted on the pipe exterior, and each transmits an ultrasonic pulse to the opposite sensor.
The difference in the transit times of the two waves is used to calculate the flow velocity.
SPECIFICATIONS
Service: Liquid flow through which ultrasonic signal can be transmitted
(water, sea water, oil, and fluid of unknown velocity).
Turbidity: 10000 deg (mg/L) or less.
Type of Flow: Well-developed turbulent or laminar flow in a full-filled pipe.
Range: 0 to ±105 fps (0 to ±32 m/s) (bidirectional flow).
Flow Pipe Sizes: SX1-A: 1.97 to 15.75 in (50 to 400 mm); SX1-B: 1.97 to 47.24 in
(50 to 1200 mm); SX1-C: 7.87 to 236.2 in (200 to 6000 mm).
Accuracy:
Pipe Size: 0.51 in (13 mm) to under 1.99 in (50 mm)
±0.03 m/s for flow rate: Under 2 m/s
±0.75% to ±1.5% of rate for flow rate: 2 m/s to 32 m/s;
Pipe Size: 1.99 in (50 mm) to under 11.8 in (300 mm)
±0.02 m/s for flow rate: Under 2 m/s
±0.5% to ±1.0% of rate for flow rate: 1 m/s to 32 m/s;
Pipe Size: 11.8 in (300 mm) up to 19.69 ft (6000 mm)
±0.01 m/s for flow rate: Under 1 m/s
±0.5% to ±1.0% of rate for flow rate 1 m/s to 32 m/s.
Response Time: 0.5s or less.
Temperature Limits: Ambient 176°F (80°C); Fluid temperature: -40 to 176°F
(-40 to 80°C) for SX1-A, SX1-B, SX1-C.
Enclosure Rating: IP67
Materials: SX1A: Plastic case; 304 stainless steel and plastic guide rail; SX1B and
SX1C: Plastic case; Silicone rubber couplers on all models.
Sensor Cable: Radio frequency coaxial cable (RG-58A/U), see accessories table
for specific lengths.
Electrical Connection: Screw terminals.
Mounting: Clamped on pipe wall.
Weight: SX1-A: 2.2 lb (1 kg); SX1-B: 0.88 lb (0.4 kg); SX1-C: 3.1 lb (1.4 kg).
Series SX1 Ultrasonic Flowmeter Detector:
• Easy installation, no pipe work required
• Simple maintenance, no moving parts
• Free from pressure loss, choking, and leakage
• Clamp-on features allow for reduction of total ownership cost
Model
SX1-A
SX1-B
SX1-C
Description
Detector, Small Sensor
Detector, Medium Sensor
Detector, Large Sensor
ACCESSORIES
Model
SXC-1A
SXC-1B
A-186
A-187
A-188
Description
16.4 ft (5 m) cable for SX1
32.8 ft (10 m) cable for SX1
Silicone-based grease acoustic couplant, 3 oz tube
Silicone RTV acoustic couplant, 4 oz tube
Silicone-free acoustic couplant, 4 oz tube
OPTIONS
Consult factory for other cable lengths.
228
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
229:Layout 2
7/20/11
3:21 PM
Page 1
Series
SX2
Portable Ultrasonic Flowmeter Detector
Compact and Lightweight
SADDLE
SCALE (mm)
SCALE
SADDLE
MM
SCALE
SPACING: 0-5-1/4
[133.00]
CURSOR
CONNECTOR
12-19/32
[320]
SPACING:
0~13˝
[0~330]
LOCK NUT
ELEMENT
HOLDER
3-35/64 MAX
[90 MAX]
2-1/16
[52.5]
20-7/8
[530]
NAME PLATE
INCH
SX2-B
SCALE (mm)
BNC
CONNECTOR
NAME PLATE
LOCK NUT
1-7/16 [36]
SX2-A SMALL DIAMETER SENSOR
CURSOR
ø1-1/32
[ø26]
8-5/64 MAX
[205 MAX]
1-19/64
[33]
3-35/64 MAX
[90 MAX]
SX2-B HIGH TEMPERATURE SENSOR
SX2-A
FLOW
1-23/32
[44.00]
Series SX2 Ultrasonic Flowmeter Detectors are paired with Series UXF1 and UXF3
converters in order to utilize the transit-time method for measuring flow rates in pipes
from the outside. Two ultrasonic sensors are mounted on the pipe exterior, and each
transmits an ultrasonic pulse to the opposite sensor. The difference in the transit times of
the two waves is used to calculate the flow velocity. Paired with the UXF1 or UXF3 Series
converters, Series SX2 detectors provide ultrasonic flowmeter sensors for both small
diameter needs as well as high-temperature applications.
ACCESSORIES
Description
Model
Silicone-based grease acoustic couplant, 3 oz tube
A-186
Silicone RTV acoustic couplant, 4 oz tube
A-187
Silicone-free acoustic couplant, 4 oz tube
A-188
Model Description
SX2-A Detector, Small Diameter Sensor
SX2-B Detector, High Temperature Sensor
CALL TO ORDER:
Cable Length ft (m)
16.4 (5)
16.4 (5)
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
229
Flow Transmitters,
Ultrasonic
Series SX2 Ultrasonic Flowmeter Detectors:
• Easy installation, no pipe work required
• Simple maintenance, no moving parts
• Free from pressure loss, choking, and leakage
• Clamp-on features allow for reduction of total ownership cost
SPECIFICATIONS
Service: Liquid flow through which ultrasonic signal can be transmitted (water, sea
water, oil, and fluid of unknown velocity).
Turbidity: 10000 deg (mg/L) or less.
Type of Flow: Well-developed turbulent or laminar flow in a full-filled pipe.
Range: 0 to ±105 fps (0 to ±32 m/s) (bidirectional flow).
Flow Pipe Sizes: SX2-A: 0.51 to 3.94 in (13 to 100 mm), SX2-B: 1.97 to 15.75 in
(50 to 400 mm).
Accuracy:
Pipe Size:
0.51 in (13 mm) to under 1.99 in (50 mm)
±0.03 m/s for flow rate: Under 2 m/s
±0.75% to ±1.5% of rate for flow rate: 2 m/s to 32 m/s;
Pipe Size: 1.99 in (50 mm) to under 11.8 in (300 mm)
±0.02 m/s for flow rate: Under 2 m/s
±0.5% to ±1.0% of rate for flow rate: 1 m/s to 32 m/s;
Pipe Size: 11.8 in (300 mm) up to 19.69 ft (6000 mm)
±0.01 m/s for flow rate: Under 1 m/s
±0.5% to ±1.0% of rate for flow rate: 1 m/s to 32 m/s.
Response Time: 0.5s or less.
Temperature Limits: Ambient 176°F (80°C); Fluid temperature: -40 to 212°F (-40
to 100°C) for SX2-A, -40 to 392°F (-40 to 200°C) for SX2-B.
Enclosure Rating: NEMA 3 (IP52).
Materials: SX2-A: Plastic case, aluminum and plastic guide rail, silicone rubber
coupler; SX2-B: 304SS case, aluminum and 304SS guide rail, silicone grease
coupler.
Sensor Cable: Radio frequency coaxial cable (RG-58A/U), 16.4 ft (5 m).
Electrical Connection: Screw terminals.
Mounting: Clamped on pipe wall.
Weight: SX2-A: 1.32 lb (0.6 kg); SX2-B: 3.53 lb (1.6 kg).
230:Layout 2
7/13/11
3:23 PM
Page 1
Series
UXF2
Ultrasonic Flow Converter
Excellent Performance and Easy Operation
MOUNTING PLATE
PIPE MOUNT (OPTION)
2-23/32
[69]
3/32
[2.5]
5-1/8
[130]
2-3/4
[70]
MOUNTING 2X ø23/64 [ø9]
23/64
[9]
6-45/64
[170]
7-3/4
[197]
(M8) U BOLT
5-33/64
[140]
MOUNTING PIPE
5-13/32
[137]
EARTH TERMINAL
Flow Transmitters,
Ultrasonic
FLOW
CABLE GLAND
3-5/16
[84]
(PG13.5) FOR POWER SUPPLY
& OUTPUT CABLE
SPECIFICATIONS
Service: Clean liquids that pass ultrasound and do not contain air
bubbles (such as pure water and chemical solution).
Input: BNC connector, coaxial cable from sensor.
Range: 0 to ± 32.8 fps (0 to ±10 m/s).
Display: 2-color LED (normal: green, abnormal: red), LCD with 2 lines
of 16 characters and back light, Languages: English, Japanese, French,
German, or Spanish.
Accuracy: See SX3.
Power Requirement: 100 to 120 VAC ± 10% 50/60 Hz, or 200 to 240
VAC ± 10% 50/60 Hz, or 20 to 30 VDC.
Power Consumption: 15 VA or less for AC power supply, 5W or less for
DC power supply.
Temperature Limits: Ambient 122°F (50°C).
Outputs: Analog: 4 to 20 mA DC, 1 point; Digital: Open Collector: 1
point; Relay contact: 1 point.
Serial Communications: RS-232C or RS-485.
Enclosure Rating: IP65.
Materials: Plastic ABS.
Electrical Connections: Screw terminals.
Mounting: Wall or pipe mount.
Weight: 1.8 lb (0.8 kg).
Series UXF2 Ultrasonic Flow Converters are paired with Series SX3
detectors in order to utilize the transit-time measuring method. Two ultrasonic
sensors are mounted on the pipe exterior, and each transmits an ultrasonic
pulse to the opposite sensor. The difference in the transit times of the two waves
is used to calculate the flow velocity. This meter is a clamp-on type ultrasonic
flowmeter for permanent use and is ideal for clean liquids containing no air
bubbles such as pure water. The easy-to-use compact and lightweight design is
intended for integration into mechanical devices. The adoption of a sound
velocity measurement system, which calculates sound velocity from the transit
time, keeps the flowmeter unaffected by the temperature and the pressure of
the fluid to be measured. Additionally, with the use of a high-speed transit time
processor, the system cycle is 0.2 seconds and applicable to short batch
processes.
Series UXF2 Ultrasonic Flowmeter Converter:
• Compact and lightweight
• Easy operation by external keypads
• Plastic housing with IP65 rating
• Communication and synchronization options available
Model
UXF2-11P1
UXF2-21P1
UXF2-31P1
UXF2-12P1
UXF2-22P1
UXF2-32P1
UXF2-13P1
UXF2-23P1
UXF2-33P1
UXF2-14P1
UXF2-24P1
UXF2-34P1
230
Power Supply
100 to 120 VAC
200 to 240 VAC
20 to 30 VDC
100 to 120 VAC
200 to 240 VAC
20 to 30 VDC
100 to 120 VAC
200 to 240 VAC
20 to 30 VDC
100 to 120 VAC
200 to 240 VAC
20 to 30 VDC
Communication
None
None
None
RS-232
RS-232
RS-232
RS-485
RS-485
RS-485
Sync
Sync
Sync
VISIT OUR WEBSITES:
www.dwyer-inst.com
(PG9) FOR SENSOR CABLE
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
231:Layout 2
7/13/11
3:24 PM
Page 1
Ultrasonic Flowmeter Detector
Series
SX3
Quick and Easy Mounting
FRAME
FRAME
BNC
CONNECTOR
SENSOR
NAME PLATE
SENSOR
SPACING
ADJUSTABLE
EVERY 7/64 [3]
16-5/32
[410.16]
L
15-3/4
[400.00]
1-15/32
[37.00]
SPACING: 0-10-5/8
[270.00]
1-27/32
[46.99]
1-11/32
[34]
2-1/8
[54.00]
SENSOR
LOCK CLIP
1-7/64
[28]
NAME PLATE
H
1-21/32
[50]
WIRE ROPE
1-13/16
[46.00]
SX3-D
SX3-A AND SX3-B
3/16 [5.08]
1-31/32
[50.00]
L
8-31/32
[288]
13-45/64
[348]
H
1-7/32
[31]
1-3/16
[30]
Spacing
53/64~4-47/64
[21~120]
53/64~9-29/64
[21~240]
Units
inches
[mm]
inches
[mm]
1-5/16 [33.00]
FLOW
Type Pipe Size
SX3-A 3/4~3-1/2
[25~100]
SX3-B 2~8
[50-225]
CHAIN
MOUNTING SPRING
1-13/16
[46.00]
FRAME GUIDE
5/16
[8.00]
SX3-C
Series SX3 Ultrasonic Flowmeter Detectors:
• Helps ensure pumping efficiency
• Provides accurate leak detection
• Not influenced by fluid’s temperature or pressure
Model
SX3-A0
SX3-B0
SX3-C0
SX3-D0
Kind of Detector
Small Standard
Small
Medium
Large
Acoustic
Coupler
None
None
None
None
Flow Pipe Size in (mm)
0.98 to 3.94 (25 to 100)
1.97 to 8.86 (50 to 225)
1.97 to 11.81 (50 to 300)
11.81 to 23.62 (300 to 600)
ACCESSORIES
Model
Description
A-186
Silicone-based grease acoustic couplant, 3 oz tube
A-187
Silicone RTV acoustic couplant, 4 oz tube
A-188
Silicone-free acoustic couplant, 4 oz tube
Model
SX3C-1A
SX3C-1B
SX3C-2A
SX3C-2B
Description
Heat Resistant Cable with waterproof BNC connector for SX3-A and SX3-B
Heat Resistant Cable with waterproof BNC connector for SX3-A and SX3-B
Heat Resistant Cable for SX3-C and SX3-D
Heat Resistant Cable for SX3-C and SX3-D
SPECIFICATIONS
Service: Clean liquids that pass ultrasound and do not contain air bubbles (such
as pure water and chemical solution).
Turbidity: 10000 deg (mg/L) or less.
Type of Flow: Well-developed turbulent or laminar flow in a fluid-filled pipe.
Permissible Air Volume Rate: Up to 2% at 1 m/s (inversely proportional to
velocity).
Range: 0 to ± 32.8 fps (0 to ±10 m/s).
Flow Pipe Sizes: SX3A: 0.98 to 3.94 in (25 to 100 mm) for plastic piping 1.97 to
3.94 in (50 to 100 mm) for metal piping; SX3B: 1.97 to 8.86 in (50 to 225 mm);
SX3C: 1.97 to 11.81 in (50 to 300 mm); SX3D: 11.81 to 23.62 in (300 to 600 mm).
Accuracy: 1.5 to 2% of rate.
Response Time: System cycle: 0.2 s; Dead time: 0.2 s or less; Time constant:
0.1s.
Temperature Limits: Ambient -4 to 140°F (-20 to 60°C); Fluid Temperature:
SX3A/SX3B: -4 to 212°F (-20 to 100°C); SX3C/SX3D w/ silicone rubber for
acoustic couplant: -4 to 176°F (-20 to 80°C), w/ silicone free grease for acoustic
couplant: 32 to 140°F (0 to 60°C).
Enclosure Rating: SX3A and SX3B: IP65 (jetproof) when using waterproof BNC
connector; SX3C and SX3D: IP67 (immersion-proof) when the terminal block is
filled with silicone rubber after wiring.
Materials: For SX3A and SX3B: Plastic PBT for sensor housing, 304SS for guide
frame; For SX3C and SX3D: Plastic PBT for sensor housing, 304SS for sensor
cover, 304SS and PBT for guide rail.
Electrical Connection: Coaxial cable up to 98.4 ft (30 m) and thermal stability of
212°F (100°C).
Mounting: Clamped on pipe surface.
Weight: SX3A: 10.6 oz (0.3 kg); SX3B: 14.1 oz (0.4 kg); SX3C: 2.2 lb (1 kg);
SX3D: 14.1 oz (0.4 kg).
Cable Length ft (m)
16.4 (5)
32.8 (10)
16.4 (5)
32.8 (10)
Option-Consult factory for other cable lengths.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
231
Flow Transmitters,
Ultrasonic
Series SX3 Ultrasonic Flowmeter Detectors are paired with Series UXF2 converters
and employ a clamp-on type design for permanent use based on transit time measuring
method. These detectors are ideal for clean liquids containing no air bubbles such as pure
water. The easy-to-use compact and lightweight design is intended for integration into
mechanical devices. It is applicable for small to medium size pipes of diameter range from
1 to 23 in (25 to 600 mm) and provides superior cost performance.
232:Layout 2
7/13/11
3:24 PM
Page 1
Series
PUX2
Portable Ultrasonic Flowmeter Converter
Data Logging and BTU Capability
PUX2 WITHOUT PRINTER
2-9/16
[65.00]
4-23/32
[120.00]
4X M4X5
DOWNSTREAM
SENSOR
UPSTREAM
SENSOR
8-17/64
[210.00]
ANALOG
INPUT/OUTPUT
DC POWER
INPUT
12-19/32
[320.00]
REMOVABLE COVER
VIEW UNDER REMOVABLE COVER
Flow Transmitters,
Ultrasonic
FLOW
SD SLOT USB PORT LCD
CONTRAST ADJUSTMENT
PUX2-PR WITH PRINTER
The Series PUX2 Portable Ultrasonic Flowmeter Converters are paired
with Series PSX2 sensors in order to utilize the transit-time difference for
measuring flow rates in pipes from the outside. It is a compact and lightweight
instrument incorporating the latest electronics and digital signal processing
technologies, realizing high performance and easy operation. This device is
designed for high accuracy and high-speed response. This portable unit is
capable of 12 hours of continuous operation with its built-in battery, which
requires only 3 hours to recharge. The rugged NEMA 3X enclosure allows the
PUX2 to be exposed to rain, while the efficient layout of the function keys aid
the user with easy page selection and setting changes. The built in USB port
allows for easy connection to a personal computer. See bulletin F-9-PUX2 for
more details.
SPECIFICATIONS
Service: Homogenous liquids (water, sea water, oil, and fluid of
unknown velocity) capable of ultrasonic wave propagation.
Inputs: BNC connector, coaxial cable from flow sensor. Two 4-20 mA
DC, or one 4-20 mA DC and one 1 to 5 V DC.
Range: 1 to ±105 fps (0.3 to ±32 m/s).
Display: LCD 240 x 320 dot (with back light).
Accuracy: ±1.0 % of rate.
Power Requirements: Built in special type lithium battery (continuous
operation time: 12 hours without printer and back light off) (recharging
time: 3 hours, power adapter used).
Power Consumption: 3W.
Power Adapter: Special type power adapter 90 to 264 VAC, 50/60 Hz.
Power Failure Backup: Memory backup with lithium battery (effective
term, 10 years).
Temperature Limits: Ambient 131°F (55°C) without printer; 113°F
(45°C) with printer.
Output: 4 to 20 mA DC, 1 point (load resistance, 0 to 600 Ω).
Serial Communications: RS-485, 1 point.
Enclosure Rating: NEMA 3X (IP64) (without printer).
Material: Plastic case.
Weight: 2.2 lb (1 kg) without printer; 2.65 lb (1.2 kg) with printer.
FEATURES
• SD memory card slot for recording data
• USB port for easy PC connection
• High accuracy
• Large type color graphic LCD
• Flow rate, flow velocity, and flow totalization functions
• Thermal flow rate (BTU) function with two temperature inputs perfect for
energy audits
Model
PUX2
PUX2-PR
Portable Ultrasonic
Flowmeter Converter
Converter
Converter with Printer
Unit includes 5 m coaxial cable for use with PSX2-A sensor.
232
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
233:Layout 2
7/20/11
3:24 PM
Page 1
Portable Ultrasonic Flowmeter Detector
Series
PSX2
Compact and Lightweight
SADDLE
SADDLE
SCALE
(MM)
SCALE
DISTANCE
BETWEEN
TWO
ELEMENTS
SCALE
CONNECTOR
LOCK NUT
ELEMENT
HOLDER
SCALE
21-1/4
[540]
SADDLE
SPACING
0 ˜ 13˝
[0 ˜ 330]
20-7/8
[530]
LOCK NUT
ELEMENT
HOLDER
LOCK NUT
ELEMENT
HOLDER
CURSOR
1-27/64
[36]
3-35/64 MAX
[90 MAX]
2-1/16
[52.5]
1-5/16
[33]
CONNECTOR
CURSOR
PSX2-B SMALL
DIAMETER SENSOR
SCALE
(MM)
BNC
CONNECTOR
12-19/32
[320]
DISTANCE
BETWEEN
TWO
ELEMENTS
1-7/16
[36]
3-35/64 MAX
[90 MAX]
CURSOR
2-1/16
[52.5]
SCALE
(MM)
1-5/16
[33]
Ø1-1/32
[Ø26]
1-19/64
[33]
8-5/64
[205 MAX]
3-35/64
[90 MAX]
PSX2-HT HIGH
TEMPERATURE SENSOR
PSX2-A SMALL SENSOR
(STANDARD)
FLOW
2-3/64
[52]
3-5/8
[92]
3-1/16
[78]
CABLE
(L=5 METERS)
WIRE ROPE
BNC CONNECTOR
2-5/8
[67]
Series PSX2 Portable Ultrasonic Flowmeter Detectors are paired with Series PUX
and PUX2 converters in order to utilize the transit-time difference for measuring flow rates
in pipes from the outside. It is a compact and lightweight instrument incorporating the latest
electronics and digital signal processing technologies, realizing high performance and easy
operation. Series PSX2 Detectors are non-intrusive clamp-on sensors and are easy to install,
require simple maintenance, and are free from pressure-loss, choking, corrosion, and
leaking.
ACCESSORIES
Model
A-186
A-187
A-188
Model
PSX2-A
PSX2-B
PSX2-D
PSX2-HT
Description
Silicone-based grease acoustic couplant, 3 oz tube
Silicone RTV acoustic couplant, 4 oz tube
Silicone-free acoustic couplant, 4 oz tube
Description
Small Sensor (2 MHz), General Use Structure
Small Diameter Sensor, General Use Structure, 5 m Coaxial Cable
Large Sensor, General Use Structure, 5 m Coaxial Cable
High-Temperature Sensor, General Use Structure, 5 m Coaxial Cable
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Service: Homogenous liquids (water, sea water, oil, and fluid of unknown velocity)
capable of ultrasonic wave propagation; Turbidity: 10000 deg. (mg/L) or less; State
of flow: Axis-symmetric flow in pipe filled with fluid.
Range: 0 to ±105 fps (0 to +32 m/s).
Accuracy: ±1.0% of rate, except PSX2-B: ±1.5% of rate.
Response Time: 1s or less.
Temperature Limits: Ambient 140°F (60°C); Fluid Temperature: PSX2-B: -40 to
212°F (-40 to 100°C) PSX2-D, and PSX2-E: -40 to 176°F (-40 to 80°C) PSX2-HT: 40 to 392°F (-40 to 200°C).
Enclosure Rating: Drip-proof, IP52 (NEMA 5); Large sensor, immersion proof,
IP67 (NEMA 6).
Materials: PSX2-E, PSX2-B, and PSX2-D: Plastic case, and aluminum alloy and
plastic mounting bracket; PSX2-HT: 304SS case, and aluminum alloy and 304SS
mounting bracket.
Electrical Connection: Terminal screws.
Mounting: PSX2-E and PSX2-B: Plastic cloth belt; PSX2-D: Stainless steel wire;
PSX2-HT: Stainless steel belt.
Weight: PSX2-E: 1.32 lb (0.6 kg); PSX2-B: 1.76 lb (0.8 kg); PSX2-D: 3.1 lb (1.4
kg); PSX2-HT: 3.75 lb (1.6 kg).
Flow Pipe Sizes
1.97 to 15.75 in (50 to 400 mm)
0.51 to 3.94 in (13 to 100 mm)
7.87 to 236.22 in (200 to 6000 mm)
1.97 to 15.75 in (50 to 400 mm)
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
233
Flow Transmitters,
Ultrasonic
PSX2-D LARGE
SENSOR
234:Layout 2
7/13/11
3:25 PM
Page 1
Series
TDT
Thermal Dispersion Flow Transmitter
No Moving Parts, 4 to 20 mA Output, Adjustable Insertion Mounting
ZERO POINT
POTENTIOMETER
INDICATING
LED
6X 60°
MEASUREMENT RANGE
POTENTIOMETER
2-33/64
[64.00]
19/64
[7.50]
3-89/127
[7.50]
5-80/127
[143.0]
1-11/32
[34.00]
85/127
[17.0]
Ø31/32
[Ø24.60]
Flow Transmitters,
Thermal Dispersion
FLOW
SIDE
SPECIFICATIONS
Service: Water, oil, compatible liquids, paste, glue, sludge and grease.
Wetted Materials: 316 SS, optional titanium.
Flow Range:
Min: 0 to 0.66 ft/s (0 to 20 cm/s);
Max: See model chart.
Temperature Range: (For optional output only) 32 to 212°F (0 to 100°C).
Accuracy: <3% of full range.
Repeatability: <1%.
Response Time: 10 seconds.
Temperature Limits:
Process: 32 to 176°F (0 to 80°C);
Ambient: -4 to 160°F (-20 to 70°C).
Pressure Limits: 261 psi (18 bar).
Process Connections: 1-1/2˝ male NPT.
Output Signal: 4 to 20 mA for flow, optional 4 to 20 mA for temperature.
Power Requirements: 24 VDC +10 to 15%.
Resistive Load: 0 to 600 Ω.
Current Consumption: Approx. 100 to 200 mA (max. flow).
Electrical Connection: 6.5 ft (2 m) moulded oilflex cable with three 21 AWG (0.5 sq
mm) wires.
Enclosure Rating: NEMA 4X (IP65).
Shipping Weight: 2 lb (907 g).
PRINCIPLES OF OPERATION
The sensor head of the Thermal Dispersion Transmitter contains two PT-resistors.
One of them is measuring the temperature of the media, while the other is heated
by an attached heating resistor. The temperature difference between the two PTresistors is predetermined and a control circuit keeps this temperature difference
constant. The flow of the media cools the heated PT-resistor proportional to the
speed of the flow, this results in a linear output signal proportional to the flow speed.
Example
Series
Base Type
Wetted Material
Range
Extension
Output
234
1-1/32
[26.00]
TOP
The Series TDT is an excellent alternative to turbine and paddlewheel insertion flow
meters, with the ability to deliver high accuracy over a wide range of pipe sizes. This unit
has the same insertion mounting into a 1-1/2˝ NPT but no moving parts to wear, break, or
clog. This transmitter has available extensions that can be used for pipes sized up to 75˝
in diameter. The TDT Dispersion Transmitter measures even very low flow rates due to
the applied calorimetric principle, and can be used for the metering of all fluid media such
as: water, oil, aggressive media, paste, glue, sludge, grease, etc. Optional titanium allows
this transmitter to be used with an even wider range of corrosive media, and the optional
output allows the user to measure both flow and temperature. When deciding on the correct
length, use the 1/7th law (the TDT’s probe length needs to measure 1/7th of the pipe
diameter).
Model
TDT-WS-301
TDT-WS-401
1-11/16
[43.00]
Description
Water base, 316 SS, 0 to 6.56 ft/s (0 to 2 m/s)
Water base, 316 SS, 0 to 9.84 ft/s (0 to 3 m/s)
TDT
TDT
W
S
1
0 1
W
L
S
T
1
2
3
4
5
0
1
2
1
2
TDT-WS-101
Thermal Dispersion Transmitter
Water based fluids
Oil based fluids
316 SS
Titanium
0 to 1.64 ft/s (0 to 0.5 m/s)
0 to 3.28 ft/s (0 to 1 m/s)
0 to 6.56 ft/s (0 to 2 m/s)
0 to 9.84 ft/s (0 to 3 m/s)
0 to 12.47 ft/s (0 to 3.8 m/s)
None
+10.28˝ (+261 mm)
+15.75˝ (+400 mm)
1 flow output
1 flow output plus 1 temperature output
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
FEATURES
• No moving parts
• Low pressure drop
• Base model works for pipe sizes of 1 to 24˝ inner diameter,
with adjustable insertion mounting
• Adjustable zero and span
• Weatherproof construction for wide application usage
• 316 SS for excellent chemical compatibility
• Optional titanium for high corrosive media
• Optional secondary output for temperature
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
235:Layout 2
7/13/11
3:26 PM
Page 1
Series
TDMT
Thermal Dispersion Flow Meter
No Moving Parts, 4 to 20 mA Output
35/64
[14.00]
INDICATING
LED
ZERO POINT
POTENTIOMETER
MEASUREMENT RANGE
POTENTIOMETER
4-5/16
[109.50]
1-17/64
[32.00]
SIDE
UNION NUT
(INCLUDED)
TOP
Model
TDMT-WS-1101
TDMT-WS-1201
Example
Series
Base Type
Description
Water base, 1˝ unit, 0 to 6.56 ft/s (0 to 2 m/s)
Water base, 1-1/4˝ unit, 0 to 6.56 ft/s (0 to 2 m/s)
TDMT W
TDMT
W
L
Wetted Material
Range
Fitting
S
1
1 0
1
S
T
1
2
3
1
2
Extension
Output
CALL TO ORDER:
0
1
1
2
TDMT-WS-1101
Thermal Dispersion Flow Meter
Water based fluids
Oil based fluids
316 SS
Titanium
0 to 6.56 ft/s (0 to 2 m/s)
0 to 9.84 ft/s (0 to 3 m/s)
0 to 13.12 ft/s (0 to 4 m/s)
1˝ unit with 1˝ NPT union nut
(up to 4˝ inner pipe diameter)
1-1/4˝ unit with 1-1/4˝ NPT union nut
(4˝ to 10˝ inner pipe diameter)
None
+7.87˝ (+ 200 mm)
1 flow output
1 flow output plus 1 temperature output
(only available with 1˝ NPT unit)
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
FEATURES
• No moving parts
• Non-intrusive sensing
• Adjustable measuring range
• Base model works for pipe sizes up to 4˝ in diameter
• Weatherproof construction for wide application usage
• 316 SS for excellent chemical compatibility
• Optional titanium for high corrosive media
• Optional secondary output for temperature
•
Australia Phone (+61) (0) 2 4272 2055
235
Flow Transmitters,
Thermal Dispersion
PRINCIPLES OF OPERATION
The TDMT operates according to a new calorimetric principle, allowing for a wide
measuring range. This meter also provides a very short integration time, even at low
flow rates, making it ideal for quick control loops. Its measurement accuracy at low
flow rates is considerably better than all other competing measurement devices.
SPECIFICATIONS
Service: Water, oil, compatible liquids, paste, glue, sludge and grease.
Wetted Materials: 316 SS, optional titanium.
Flow Range:
Min: 0 to 0.66 ft/s (0 to 20 cm/s);
Max: See model chart.
Temperature Range: (For optional output only) 32 to 212°F (0 to 100°C).
Accuracy: <3% of full range.
Repeatability: <1%.
Response Time: 10 seconds.
Temperature Limits:
Process: 14 to 176°F (-10 to 80°C);
Ambient: 14 to 140°F (-10 to 60°C).
Pressure Limits: 435 psi (30 bar).
Process Connections:
1˝ unit: 1˝ NPT union nut;
1-1/4˝ unit: 1-1/4˝ NPT union nut.
Output Signal: 4 to 20 mA for flow, optional 4 to 20 mA for temperature.
Power Requirements: 24 VDC ±10%.
Resistive Load: 0 to 600 Ω.
Current Consumption: Approx. 100 to 200 mA (max. flow).
Electrical Connection: 6.5 ft (2 m) moulded oilflex cable with three 21 AWG (0.5 sq
mm) wires.
Enclosure Rating: NEMA 4X (IP65).
Shipping Weight:
1˝ unit: 5.6 oz (158.76 g);
1-1/4˝ unit: 13.4 oz (379.88 g).
FLOW
The Series TDMT Flow Meter is for use in industrial applications, and can be easily
installed virtually non-intrusively into any pipe. This non-intrusive installation allows flowsensing without obstruction of the pipe diameter. It is completely encapsulated in epoxy
resin and is compact, rugged, shock and vibration resistant. It provides proven reliability
and long-term stability, even under the harshest environmental conditions. The TDMT is
made of stainless steel with a titanium option making it resistant to aggressive media. In
addition to its small and compact size, the TDMT also comes with a choice of a 1˝ unit with
1˝ NPT union nut or a 1-1/4˝ unit with 1-1/4˝ union nut, as well as available extensions
that can be used for pipes sized up to 10˝ in diameter. With an optional temperature
output, this meter provides the user with a very broad range of usage. When trying to
decide on the correct length, use the 1/7th law (the TDMT’s probe length needs to be
1/7th of the pipe diameter).
1-1/2
[38.00]
236:Layout 2
7/13/11
3:26 PM
Page 1
Series
DMF
Digital Mass Flow Controllers
Programmable, RS485 Interface, Up To 500 psig, ±1% Accuracy
6-5/8
[167.13]
1 7/8
[47.75]
Mass Flowmeters/
Controllers
FLOW
3/4
[17.53]
Program, record, analyze, and control flow rates of various gases with Series DMF
Digital Mass Flow Controller. Controllers are designed with straight tube sensors with
restrictor flow elements to ensure laminar gas flow for accurate and repeatable results.
Series DMF are unaffected by temperature and pressure variations.
Controllers can be programmed for various control functions including flow set point,
totalizer, stop totalizer, totalize from preset flow, stop and preset total, auto zero, and more.
Auto zero feature utilizes an automatic balancing circuit that virtually eliminates drift of
zero and span. In addition, Series DMF controllers have two dry contact closures to operate
pumps, valves, or other process equipment.
The Series DMF features an auto tune function to optimize control response for a specific
gas under actual process conditions. Self diagnostic tests are run at power up to ensure the
controller is in optimum working condition. Calibration information for up to 10 gases and
conversion factors for up to 256 different gases are stored in memory. High and low gas
flow alarm limits are programmed via RS-485 interface. Software supports programmable
flow modes, allowing execution of custom programming of up to ten steps.
6 1/4
[157.23]
1 1/2
[38.10]
5 5/8 or 5 7/8*
[143.51]
5 1/4
[133.86]
3/4
[17.53]
2 7/8
[74.42]
6-32
FOR FLOW ≥ 15 L/M
2 3/4
6-32
[68.33]
*FOR FLOW ≥ 60 L/M
SPECIFICATIONS
Service: Clean gases compatible with wetted parts.
Wetted Materials: 316 SS, 416 SS, fluoroelastomer O-rings.
Accuracy: ±1% FS including linearity between 59 to 77°F (15 to 25°C) and 10 to
60 psia (0.7 to 4 bar); ±2% FS from 32 to 122°F (0 to 50°C) and 5 to 150 psia
(0.3 to 10 bar).
Repeatability: ±0.15% of full scale.
Response Time: 0.6 to 1.0 second to within ±2% of setpoint over 20% to 100%
FS.
Output: Linear 0-5 VDC (2000 Ω min. load impedance); 0-10 VDC (4000 Ω min.
load impedance).
Maximum Particulate Size: 100 microns.
Temperature Limits: 41 to 122°F (5 to 50°C).
Power Supply: ±15 VDC; 13.5 watts maximum.
Process Connections: 1/4˝ compression fitting for flow rates ≤50 L/m; 3/8˝ for
flows ≥60 L/m.
Pressure Limits: 500 psig (34.5 bar).
Leak Integrity: 1 x 10-9 sccs of helium.
Computer Interface: RS-485.
Agency Approvals: CE.
Model*
Range
Model*
Range
DMF-41401 0 to 10 sccm
DMF-41408 0 to 2 L/min
DMF-41402 0 to 20 sccm
DMF-41409 0 to 5 L/min
DMF-41403 0 to 50 sccm
DMF-41411 0 to 15 L/min
DMF-41404 0 to 100 sccm DMF-41431 0 to 30 L/min
DMF-41405 0 to 200 sccm DMF-41433 0 to 50 L/min
DMF-41406 0 to 500 sccm DMF-41842 0 to 100 L/min
DMF-41407 0 to 1 L/min
*Specified flow ranges are for an equivalent flow of nitrogen
at 70°F (21°C) @ 760 mm Hg.
ACCESSORIES
Model DMF-110P, 110V power supply with 25-pin connector
Model DMF-220PE, 220V power supply with 25-pin connector
Model DMF-CBL1, 6 ft cable with branch to separate power supply
Model DMF-CBL2, 6 ft cable with branch to computer port
236
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
237:Layout 2
7/13/11
3:27 PM
Page 1
Series
GFM
Gas Mass Flow Meters
Flow Range Up to 1000 L/min, Pressures Up to 500 psi, NIST Traceable
3
[76.20]
1-3/4
[44.55]
1-1/8
[28.58]
3
[76.20]
5-37/64
[141.86]
5-31/32
[151.64]
4-7/8
[123.70]
1
[25.40]
5-1/64 [127.51]
6-9/64 [156]
1-1/4
[31.75]
DWYER MODEL GFM-1140 THRU
GFM-1142 & GFM-2140 THRU GFM-2142
DWYER MODEL GFM-11D1 THRU GFM 1111
& GFM-2101 THRU GFM-2111
1-1/8
[28.58]
1-3/4
[44.55]
1-3/4
[44.55]
1-3/32
[27.84]
1-3/32
[27.94]
4-1/2
[114.30]
1-1/8
[28.58]
1-1/2
[38.10]
6-1/32 [153]
3
[76.20]
DWYER MODEL GFM-1130 THRU GFM-1133
& GFM-2130 THRU GFM-2133
1-7/16
[36.51]
4-35/64
[115.57]
FLOW
4
[101.60]
4
[101.60]
Series GFM Gas Mass Flow Meters combine a straight tube sensor with a restrictor
flow element to provide high accuracy and repeatability. Flow rates are virtually unaffected
by temperature and pressure variations. Actual gas flow is displayed in engineering units
on a 3-digit, 90° tiltable LCD readout. Units can be used with Series GFT Flow Totalizer
for applications requiring totalization. Series GFM includes a NIST traceable certificate.
Process Connector
Flow Range Aluminum SS
Compression Fitting
0-10 mL/m
GFM-1101* GFM-2101* 1/4˝
0-20 mL/m
GFM-1102* GFM-2102* 1/4˝
0-50 mL/m
GFM-1103* GFM-2103* 1/4˝
0-100 mL/m
GFM-1104* GFM-2104* 1/4˝
0-200 mL/m
GFM-1105* GFM-2105* 1/4˝
0-500 mL/m
GFM-1106* GFM-2106* 1/4˝
7-19/64
[185.42]
SPECIFICATIONS
Service: Clean gases compatible with wetted parts.
Wetted Materials:
GFM-1XXX: Anodized aluminum, brass, 316 SS and fluoroelastomer O-rings;
GFM-2XXX: 316 SS and fluoroelastomer O-rings.
Accuracy: ±1.5% FS including linearity over 59 to 77°F (5 to 25°C) and 5 to 60
psia (0.35 to 4 bar).
Repeatability: ±0.5% of full scale.
Response Time: 2 seconds to within ±2% of actual flow.
Output: Linear 0-5 VDC and 4-20 mA.
Max. Particulate Size: 5 microns.
Temperature Limits: 32 to 122°F (0 to 50°C).
Power Supply: ±12 VDC.
Process Connections: 1/4˝ compression fitting for flow rates ≤50 L/m; 3/8˝ for
100 and 200 L/m; 1/2˝ for 500 L/min; 3/4˝ for 1000 L/min.
Pressure Limits: 500 psig (34.5 bar).
Leak Integrity: 1 x 10-7 sccs of helium.
Display: 90° tiltable, 3-1/2 digit.
Agency Approvals: CE.
0-1000 mL/m GFM-1107* GFM-2107* 1/4˝
0-2 L/min
GFM-1108* GFM-2108* 1/4˝
0-5 L/min
GFM-1109* GFM-2109* 1/4˝
0-15 L/min
GFM-1111* GFM-2111* 1/4˝
0-30 L/min
GFM-1131* GFM-2131* 1/4˝
0-50 L/min
GFM-1133* GFM-2133* 1/4˝
0-100 L/min
GFM-1142* GFM-2142* 3/8˝
0-200 L/min
GFM-1143* GFM-2143* 3/8˝
0-500 L/min
GFM-1144* GFM-2144* 1/2˝
ACCESSORIES
For Series GFM Gas Mass Flowmeters
Model GFM-110P, 110V Power Supply
Model GFM-220PE, 220V Power Supply
Model GFM-CBL4, 3 ft cable for 4-20 mA output
Model GFM-CBL5, 3 ft cable for 0-5 VDC output
Model IO-1, 0-5 VDC to RS232 Input to Output Signal Conditioner
GFT-10, Flow Totalizer with 5-10 VDC input for direct connection
to GFM and GFC (replaces GFM/GFC LCD Process display)
GFT-10C, Connection Cable for utilizing GFT-10 totalizer
in conjunction with GFM/GFC LCD process display
0-1000 L/min GFM-1145* GFM-2145* 3/4˝
*Specified flow ranges are for an equivalent flow of nitrogen at
70°F (21°C) @ 760 mm Hg.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Australia Phone (+61) (0) 2 4272 2055
237
Mass Flowmeters/
Controllers
Model
1-17/64
[32.00]
238:Layout 2
7/13/11
3:27 PM
Page 1
Series
GFC
Gas Mass Flow Controllers
Flow Range Up to 1000 L/min, Pressures Up to 500 psi, NIST Traceable
3
[76.20]
5-37/64
[141.86]
MASS
FLOW CONTROLLER
SERIES GFC
FLOW
1-1/8
[28.58]
1-3/4
[44.55]
5-31/32
[151.77]
3-9/16
[90.42]
1
6-19/64
[25.40]
[159.77]
DWYER MODEL GFC-1101 THRU GFC-1111
& GFC-2101 THRU GFC-2111
11/16
[17.53]
6-32
2 11/16
[68.33]
1-1/8
1-3/4 [28.58]
1-1/2
[44.55]
[38.10]
4-35/64
[115.57]
Mass Flowmeters/
Controllers
FLOW
4
[101.60]
4
[101.60]
Series GFC Gas Mass Flow Controllers combine a straight tube sensor with a
restrictor flow element to provide high accuracy and repeatability. Gas mass flow
controllers utilize an electromagnetic valve and PID electronics to maintain continuous
control by comparing measured sensor signal set to flow rates. Setpoints can be adjusted
with local potentiometers or remotely via 0 to 5 VDC or 4 to 20 mA analog signal. Flow
rates are virtually unaffected by temperature and pressure variations. Actual gas flow is
displayed in engineering units on a 3-digit, 90° tiltable LCD readout.Units can be used with
Series GFT Flow Totalizer for applications requiring totalization. Series GFC includes a
NIST traceable certificate.
Process Connector
Flow Range Aluminum SS
Compression Fitting
0-10 mL/m
GFC-1101* GFC-2101* 1/4˝
GFC-1102* GFC-2102* 1/4˝
0-50 mL/m
GFC-1103* GFC-2103* 1/4˝
0-100 mL/m
GFC-1104* GFC-2104* 1/4˝
0-200 mL/m
GFC-1105* GFC-2105* 1/4˝
0-500 mL/m
GFC-1106* GFC-2106* 1/4˝
1-3/4
[44.55]
MASS
FLOW CONTROLLER
SERIES GFC
3-15/16
[99.95]
FLOW
7 21/64
[186.18]
GFC-1108* GFC-2108* 1/4˝
0-5 L/min
GFC-1109* GFC-2109* 1/4˝
0-15 L/min
GFC-1111*
0-30 L/min
GFC-1131* GFC-2131* 1/4˝
0-50 L/min
GFC-1133* GFC-2133* 1/4˝
0-100 L/min
GFC-1142* GFC-2142* 3/8˝
0-200 L/min
GFC-1143* GFC-2143* 3/8˝
0-500 L/min
GFC-1144* GFC-2144* 1/2˝
MASS
FLOW CONTROLLER
SERIES GFC
FLOW
3-1/8
1-17/64 7-19/64
[79.38] 1-17/64
[32.00] [185.42]
[32.00]
DWYER MODEL GFC-1143 THRU GFC-1145
& GFC-2143 THRU GFC-2145
ACCESSORIES
For Series GFC Gas Mass Flow Controllers
Model GFC-110P, 110V Power Supply
Model GFC-220PE, 220V Power Supply
Model GFC-CBL1, 8 ft cable with 15-pin connector
Model GFC-CBL3, 3 ft extension cable for LCD readout
Model IO-1, 0-5 VDC to RS232 Input to Output Signal Conditioner
GFT-10, Flow Totalizer with 5-10 VDC input for direct connection
to GFM and GFC (replaces GFM/GFC LCD Process display)
GFT-10C, Connection Cable for utilizing GFT-10 totalizer
in conjunction with GFM/GFC LCD process display
GFC-2111* 1/4˝
0-1000 L/min GFC-1145* GFC-2145* 3/4˝
*Specified flow ranges are for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.
238
VISIT OUR WEBSITES:
www.dwyer-inst.com
1-1/4
[31.75]
DWYER MODEL
GFC-1140 THRU
GFC-1142 &
GFC-2140 THRU
7 21/64
GFC-2142
[186.18]
DWYER MODEL GFC-1130 THRU GFC-1133
& GFC-2130 THRU GFC-2133
11/16
[17.53]
6-32 2-11/16
[68.33]
3
3-11/64
[76.20]1.437
[80.65]
0-1000 mL/m GFC-1107* GFC-2107* 1/4˝
0-2 L/min
1-1/8
[28.58]
SPECIFICATIONS
Service: Clean gases compatible with wetted parts.
Wetted Materials:
GFC-1XXX: Anodized aluminum, brass, 316 SS and fluoroelastomer O-rings;
GFC-2XXX: 316 SS and fluoroelastomer O-rings.
Accuracy: ±1.5% FS including linearity over 59 to 77°F (5 to 25°C) and 5 to 60
psia (0.35 to 4 bar).
Repeatability: ±0.5% of full scale.
Response Time: 2 seconds to within ±2% of actual flow.
Output: Linear 0-5 VDC and 4-20 mA.
Max. Particulate Size: 5 microns.
Temperature Limits: 32 to 122°F (0 to 50°C).
Power Supply: ±12 VDC.
Process Connections: 1/4˝ compression fitting for flow rates ≤50 L/m; 3/8˝ for
100 and 200 L/m; 1/2˝ for 500 L/min; 3/4˝ for 1000 L/min.
Pressure Limits: 500 psig (34.5 bar).
Leak Integrity: 1 x 10-7 sccs of helium.
Display: 90° tiltable, 3-1/2 digit.
Agency Approvals: CE.
Model
0-20 mL/m
3
[76.20]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project