Short Form Catalog

Short Form Catalog
MEASUREMENT
DEVICES
DIGITAL
DISPLAYS
CONVERTERS
AND INTERFACES
INDUSTRIAL I/O’S
AND TELECONTROL
Short Form
Catalog
2
Automation
high tecnology
With over 15 years manufacturing in the industrial automation
field, SENECA has grown to be a major force on the Italian market of the industrial and process control instrumentation, establishing its strongpoint in innovation, reliability and high quality technical support. Our product automation lines, completely devised
and produced inside our Company, are consistent with and open
to the most widespread technological standards. SENECA proposes a wide range of high value-added products and systems, starting with field instrumentation and ending with monitoring and
control software, and going through a technology area inclusive of
interfacing systems, conditioning, acquisition and control. SENECA thus grants the entire signal treatment cycle, power input and
galvanic isolation included, up to the data display.
3
INNOVATIONS
The innovative product lines, professional approach and worldwide network of trained distributors guarantee
the most elegant solutions to all your process interfacing and data acquisition applications.
SENECA has built its reputation as a reliable yet innovative supplier by offering accurate, easy to use, cost and
space saving equipment on short lead times with world-class sales and technical support.
SENECA produces high innovation content instrumentation to strengthen its market position and to give to
Customers the maximum flexibility and profitability of their investments with the aim of offering specific knowhow and complete solutions, SENECA is today a leading Company for technology and innovation.
The SENECA hardware supports the state-of-the-art industrial communication protocols for remote control and
data transmission.
QUALITY
As a ISO 9001 certified company the total quality of the its
products is assured.
The full galvanic isolation features coupled with the ridged
adherence to the CE Directives guarantees the correct working in the most inhospitable environments.
STURDINESS
EN 50081-2 Electromagnetic emission compatibility – Heavy industrial environment.
EN 50082-2 Electromagnetic immunity compatibility – Heavy industrial environment.
EN 61010-1 Safety Requirements for electric measurement and control devices.
Production in SMT (Surface Mounting Technology) on a single printed circuit.
Burn-in test performed on the whole production.
High level of intrinsic immunity to electromagnetic interferences.
RINA Certification for naval applications.
UL-UR CSA mark.
PRODUCTION CONFORMING WITH INTERNATIONAL STANDARDS
SENECA has invested heavily in its own EMC laboratories to enable in depth compliance testing at all stages
of the design process.
For total confidence, the accuracy of our in house facility is regularly gauged against external compliance laboratories.
All Seneca products are fully designed, manufactured and tested in our factory using advanced Surface Mount
(SMT) and Pin Through Hole technologies (PTH) and automated test and calibration equipment.
Compliance of the production process to the RAEE and ROHS lead free standards.
4
SENECA takes care
of your signals...
K-line
FIELD
• ACTUATORS
• SENSOR
Temperature
Pressure
Level
Flow
Position
Speed
…
Digital, serial, analog,
temperature and galvanically
isolated signals
INTERFACES
AND SIGNAL
CONDITIONING
Z-line
5
Power Supply and protection
Galvanic isolation
Analog, digital and serial interfaces
Distributed I/O
Data acquisition
Telecontrol
Visualization and control
Z-PC-line
Distributed System
SUPPORTS
INFORMATION STANDARD
•
•
•
•
•
ModBUS RTU
Profibus DP Slave
CANOpen
• GSM / GPRS
• UHF / VHF
• WLAN
• UMTS
• Satellite
• ISP
• DSL
• Fiber optics
• Serial line
• PSTN
…
DATA PROCESSING
AND ACQUISITION
DATA
TRANSMISSION
PROTOCOLS
• PPP
• HTTP
• SMTP
• FTP
• Ethernet
• ModBUS TCP
• IEC 870
…
OPC
SCADA
IEC 61131
OCX / Active X
Html / Java
DATA
RECORDER
MONITORING AND
SUPERVISION
Display and Panels
Z-TOP
S line
Telecontrol unit
6
Product Lifetime
Full Control
DESIGN
SENECA has an advanced internal structure of electronic design that follows all the steps of the product development, analysis and feasibility studies, applied research, PCB and SMT design activities with the best software for simulation and industrialization prototyping electronics and
mechatronics, documentation and manuals technique. This structure
also carries on consultancies and achievements of electronics contract
basis.
The design SENECA reserves its full attention for finding components
and normative adjustment. Testing, analyzing interference, electromagnetic compatibility test, signals security and integrity - EMI are conducted by qualified (internal and external) laboratories for comparison tests.
The strategy SENECA design is in step with the most advanced microelectronic technologies (FPGA, PSoC, CPLD, ASIC, DSP, MEMS, LVDS,
VHDL), adopting a systematic approach of quality control (ISO
9001:2000, DoE methods, FTA, FMEA) and statistical analysis.
PRODUCTION
The production cycles and the internal tests are executed through the
most modern SMT (Surface Mounting Technology) and PTH (Pin
Through Hole) lines.
The capacity of our factories is thousands of components per hour, which
allows to combine high production speed, accuracy, flexibility, reduced
MTBF and time-to-market.
Since 2006 the production process is fully conform with lead free WEEE
and ROHS. On all products shall be carried out stringent test systems
with automatic generation of individuals Test report.
To manage the increasing complexity of SMT technology on electronic
cards SENECA adopts Convention forced to recast that process control
systems for welding up to the management of fluxing through a precise
and accurate control of heat transfer.
All products comply with CE for electromagnetic compatibility, the safety
requirements and regulations RINA, UL - UR - CSA for naval applications
and for the North American market, respectively.
Index
7
Short Form Catalog
Product Lifetime Cicle
6
1 • INDUSTRIAL I/O’s AND TELECONTRO
Z-PC Line • Introduction
Z-PC Line • Data Acquisition
Z-PC Line • Telecontrol
Z-PC Line • Buildings and Infrastructures
Z-PC Line • Automation
Z-PC Line • Software Platform
Z-PC Line • RTU
Z-PC Line • Control Units
Z-PC Line • Digital I/O Modules ModBUS
Z-PC Line • Analog I/O Modules ModBUS
Z-PC Line • Analog Input Modules for Temperature Control ModBUS
Z-PC Line • Special Modules
Z-PC Line • Communication Modules
Z-PC Line • CANopen Digital I/O Modules
Z-PC Line • CANopen Analog I/O Modules
Z-PC Line • Software
Z-PC Line • Software e accessories
9
10
11
12
13
13
14
16
17
18
19
20
21
22
23
24
25
25
2 • CONVERTERS AND INTERFACES
Introduction
Applicative examples
Benefits of signal conditioning
Isolators -Temperature Converters
K Line • Isolators - Analog Converters
K Line • Isolators – Serial Converters and Accessories
Z Line • Isolators - Analog Converters
Z Line • Isolators - A/D Analog Converters for PLC
Isolators – Converters for Electric Measurements
Isolators – Temperature Converters
Z Line • Isolators – Pulses Converters and Signal Elaborators
Z Line • Isolators – Relay Conditioners
Z Line • Programming and Accessories
S Line • Isolators - Analog Converters
S Line • Isolators – Pulses Converters and Signal Elaborators
S Line • Isolators – Relay Conditioners
S Line • Industrial Regulated Power-Supply for loop
S Line • Switching Regulated Power-Supply
S Line • Industrial Regulated Power-Supply from front panel
S400 • Overvoltages Protections
27
28
29
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
3 • DIGITAL DISPLAYS
Introduction
S Line • OLED / LED New Generation Display
S Line • Digital Indicators
S Line • Totalizers
S Line • Batch Controllers and Control Units
ZTOP • Operator Panels with LCD and Touch Screen display
49
50
54
55
56
57
58
4 • MEASUREMENT DEVICES
Test & Measurement
Network Analyzers
59
60
61
Quality System and technological standard
Seneca on the web
62
62
8
9
1
INDUSTRIAL I/OʼS
AND TELECONTROL
INDUSTRIAL I/OʼS AND TELECONTROL
10
Z-PC line, open system,
configurable and standard
Digital Input
Analogue Input and Output
• Acquisition and control standard analog signals
(voltage, current, ohm), power supply, transducers, resolution up to 15 bit + sign
Digital Output
• Isolated input for reed sensors, proximity, pnp, npn,
contact, inputs with fast counters up to 32 bit and 10
KHz
• SPST relay output or MosFET, delay
and fail safe programmable, front diagnostics
Special Modules: temperature control, load cells,
electric network analyzer
Connection System
and power-supply
• Direct input from RTD 2, 3 or 4 wires
• Thermocouples acquisition J, K, R, S, T, B,
E, N
• Electrical measurements acquisition from
net analyzer
• Load cell (strain gauge) acquisition
• Supports in nylon loaded PA6 with fiber glass at 30%
• Hot swapping
• Power-supply terminal /data line
• Mounting on guide-DIN 46277 in vertical position
Modular CPU and multi-functions
• PLC, Web Server, RTU, datalogger, Ethernet bridge
• ModBUS Master / Slave on RS232/RS485
• RS232 interfaces (user free/programming)
• Ethernet Port 10Base T opened to supervision networks
and remote connection
• RISC / MISC Microprocessor at 32/64 bit
• Memories: up to 32 MB RAM, 64 MB flash memory (data)
• Backup battery for retentive variables
Communication Interfaces
• Radio modules with short range 100 kbps, 10
mW, 434-869 MHz
• RS232-USB/RS485 serial Conversion Modules
Regulators
• Analogue: Z-PID, universal input, proportional,
integral, derivative action settings
• Digital: Z-D-IO, module 6 DI, 2 DO, I/O slave or
automatic functioning for pneumatic valves,
motorized and alarms management
Ethernet
Fieldbus
Serial Connection
• Html/Java Web Client
• LAN-Ethernet / ModBUS TCP
• Architetture Client/Server e VPN
OPC
SCADA
System for GSM/GPRS,
• Communication
DSL PSTN, WiLAN, UHF …
operator panels, identification
• Printer,
systems
Distributed system, supervisory and control integration
•
I/O expansion
• PLC, regulators and field devices
ModBUS RTU Master/Slave
Profibus DP (Slave)
CanOPEN (Master)
Data transmission and remote control system
Max 32 I/O modules, 1.200 m without repeater
434 / 869 MHz
100 kbps
Max 32 I/O modules, 1.200 m without repeater
RS232
RS232 / RS485
ModBUS RTU - RS485
RS232 / RS485
ModBUS RTU - RS485
Z-TWS
Z-TWS
GSM / GPRS /
PSTN / XDSL…
LAN /
WAN /
Internet
LAN /
WAN /
Internet
Ethernet - ModBUS TCP
Ethernet - ModBUS TCP
LEGEND
LEGENDA
Fieldbus / Control networks
Fieldbus / Control networks
Serial connections
Serial connections
LAN / WAN
LAN / WAN
11
Z-PC LINE – DATA ACQUISITION
Z-PC LINE for data acquisition allows the implementation of systems able to collect, process and store analog or digital
measures from industry and T&M with simple Plug&Play technology on the monitoring side and the distribuited I/O
ModBUS on the field side.
ETHERNET - MODBUS TCP / RS485
WIRELESS TRANSMISSION
RS232
Ethernet /
ModBUS TCP
Z107 - Serial
Converter
RS232/485
INDUSTRIAL I/O’S
AND TELECONTROL
RS232 / RS485
100 kpbs 10 mW
434 (869) Mhz
max 300 m
Ethernet /
ModBUS TCP
Z-TWS
Z-BRIDGE
Z-RTU
ModBUS RTU / RS485
ModBUS RTU / RS485
ModBUS RTU / RS485
Z-PC Line,
I/O
Acquisition
modules
Z-PC Line,
I/O
Acquisition
modules
Z-PC Line,
I/O
Acquisition
modules
ModBUS RTU / RS485
CONVERTERS
AND INTERFACES
Net analyzer
LabVIEW
DATALOGGING
BASATO
SU Z-TWS
DIGITAL
DISPLAYS
DATA
RECORDER
END OF
LINE TEST
MEASURE CALIBRATION AND
LABORATORY TEST
ELECTRIC CONSUMPTION
ANALISYS
TEMPERATURE
MONITORING
PORTABLE KIT FOR
DATA ACQUISITION
TESTING ROOM
CAPACITY
TEST
ACQUISITION AND
RECORDING
PROCESS ENVIRONMENT
MONITORING
WATER TREATMENT
CONTROL
MEASUREMENT
DEVICES
APPLICATIONS
INDUSTRIAL I/OʼS AND TELECONTROL
12
Z-PC LINE • TELECONTROL
Z-PC line is designed to support the systems integrators, design and engineering companies, automation, instrumentation
and specialists, electrical engineers. It ensures open technology, high connectivity in the data transmission toward and from
the remote centre. The configuration software (Z-NET3) offers a wide range of “ready-to-use” functions for remote control
(alarms, files, events management via SMS, email, voice etc.) and automation (pumps rotation, counter, pulses totalizer,
flow metering etc.).
WATER TREATMENT
AGRICULTURE/
CLIMATIC
ENGINEERING
WATER DISTRIBUTION
GAS
GSM/GPRS
PRS
RS
ENVIRONMENTAL
MONITORING
UMTS
S
INTERNET
I
CDN-DEDICATED
CD
DN-DEDICATED
DICATED
D LINE
D
ADSL X DSL
FIBER OPTICS
ETHERNET
ETH
HERNET
SATELLITE
SATELLITE
E
SERIAL LINE
LINE
SERIAL
UH
UHF
RADIO UHF/VHF
PSTN
WLAN
PUBLIC
SERVICES
ENERGY
TRAFFIC AND
TRANSPORT
INDUSTRY, MECHANICS
BUILDING
AUTOMATION
AND SAFETY
TELECONTROL INTEGRATED FUNCTIONS
EVENTES & ALARMS
MANAGEMENT VIA SMS
• Automatic alarms sending via SMS up
to 8 phone numbers groups
• Timeout, message format, multiple
phone number settings
LOG FILE MANAGEMENT VIA MAIL
• Automatic log file editing
(daily or continuous)
• Data log data transfer via e-mail
(SMTP), pre-setted trip alarms
STATUS REQUEST VIA SMS
• 3 measurements set
(2 analog + 2 digital) request
LOG FILE MANAGEMENT VIA FTP
• Automatic log file editing
(daily or continuous)
• Data log transfer via ftp
SMS CONTROL
• Remote command execution via SMS
(Max 5 phone numbers, 16 commands)
• CPU receiving, enabling variables and
digital contacts
ALARM CALLING
• Calling management RTU – supervision center
13
Z-PC LINE • BUILDINGS AND INFRASTRUCTURES
Supervision
and control
Local visualization and
data retransmission
(Modbus)
Short range radio
transmission
Temperature control,
RDT and TC
acquisition modules
ModBUS RTU
Ethernet / ModBUS TCP
Serial lines
CONVERTERS
AND INTERFACES
Alarms management
(web service,
SMS, e-mail ...)
Access
control
Energy saving control, single
and three phase analyzers
with Modbus
RTU interface
I/O devices
management (measures,
switches ...), technical
and auxiliary systems
Z-PC LINE• AUTOMATION
DIGITAL
DISPLAYS
Lighting
management
INDUSTRIAL I/O’S
AND TELECONTROL
Z-PC line is suitable for the technical management of buildings and infrastructures. This line offers a good quality /price
ratio, several modules dedicated to the temperature and electric measurements control, simplified wiring for distributed
systems, alarms, MODBUS and CANopen open protocols through which to exchange and centralize information easily.
MEASUREMENT
DEVICES
Z-PC line is also a general-purpose system for the management of small discrete, process and batch automations.
The Modbus, CANopen and Profibus interfaces allow an easy integration with pre-existing devices and 3rd part hardware
systems. The IEC 61131-3 programming system (with ISaGRAF or codesys platforms) allows the maximum flexibility
in the implementation of control logics, regulations, sequences, dosing, alarms management and trends.
INDUSTRIAL I/OʼS AND TELECONTROL
14
Z-PC Line software platform
Scada, windows runtime software, database…
Trend Viewer
DATA RECORDER
Integrated protocols
IEC 870-101 / 104
Data transmission of electric power
systems via serial line and Ethernet
Z-NET3
Data acquisition and
recording software
WEB EDITOR
System configurator (iec 61131)
Development Environment for
supervision html/java page
CPU and I/O
configuration
Database generation
and updating
Z-SMS DATA STORE
Micro RTU data and communication management
OPC Server standard
Ethernet
OPC Server
Front-end telecontrol systems
OPC Server I/O
(GPRS-IP connections with
dynamic IP, driver ModBUS)
OPC Server MB Slave
(high security GPRS connections, “ready to use” system
for IP static nodes)
CONVERTERS
AND INTERFACES
Z-NET RTU
INDUSTRIAL I/O’S
AND TELECONTROL
15
Telecontrol
Integrated Functions
Codesys
ModBUS Integrated
Functions
SENECA
Libraries
Communication
Network Configuration
Electric consumptions
Calculation, operating time,
motors rotation etc.
RS232 / RS485, TCP/IP, PPP
MEASUREMENT
DEVICES
Isagraf
DIGITAL
DISPLAYS
PLC Programming [IEC 61131]
INDUSTRIAL I/OʼS AND TELECONTROL
16
Z-PC LINE - RTU
Z-RTU
M-RTU-GP
Remote Terminal Unit 16 (8) DI, 8
(4) DO, 4 (2) AI, 2 (1) AO with
GSM/GPRS or PSTN modem
M-RTU-PC
Micro RTU
for general purpose
Micro RTU
for cathodic protection
ORDER CODES
Model
Full I/O Version
Half I/O Version
GSM Modem
PSTN Modem
Vocal Card
Telecontrol Protocols
DIN Guide
Software
Accessories
Z-RTU
-1
-2
-GSM
-PSTN
-SMART-SPEECH
-IEC 870
M-RTU-GP
M-RTU-PC
-DIN
Page 25
Page 26
-DIN
Page 25
Page 26
Range 8..30 Vdc
Internal batteries
14,4 V lithium batteries (opzional)
3 years
6..50 mW, 1,5 W (GSM transmision)
External Case IP44
Internal Case IP65
Connection IP40
Range 8..30 Vdc
Internal batteries
14,4 V lithium batteries (opzional)
3 years
6..50 mW, 1,5 W (GSM transmision)
External Case IP44
Internal Case IP65
Connection IP40
-20..+70 °C
263 x 143 x 89 mm
350 g
-20..+70 °C
65 x 130 x 55 mm
2 Kg (batteries included)
DB9F, V4 RS232 interface, SMA
socket (antenna connector)
DB9F, V4 RS232 interface, SMA
socket (antenna connector)
1 port with UART GSM
1 serial port V24-RS232, half-duplex, local connection,
selectable speed: 1.200.. 115.200 baud
1 port with UART GSM
1 serial port V24-RS232, half-duplex, local connection,
selectable speed: 1.200.. 115.200 baud
GSM Dual band full type approval
GSM Dual band full type approval
32 bit, core ARM7, 2 UARTS, low power
EEPROM: 64 kByte
FLASH: 2 MByte
32 bit, core ARM7, 2 UARTS, low power
EEPROM: 64 kByte
FLASH: 2 MByte
ModBUS RTU, PPP, http, FTP,
SMTP, (ModBUS) TCP/IP
Nr 16 (8) channel (internal/external power supply)
Nr 4 (2) isolated channels (14 bits resolution, loop power),
voltage (0..5/ 0..10 / 1..5 / 2..10 V), current (0..20 / 4..20
mA)
ModBUS RTU (CCITT V.24)
Integrated SMS protocol
Nr 2 isolated channels, sampling frequency 10 Hz
Nr 2 isolated channels against overvoltage & overcurrent
Full scale: ±2, ±20, ±50 V, ±20 mA
Resolution @ 15 bit + sign
ModBUS RTU (CCITT V.24)
Integrated SMS protocol
Nr 2 isolated channels, sampling frequency 10 Hz
Nr2 isolated channels against overvoltage and overcurrent
Input range 1: ±2, ±20, ±50 V, ±20 mA
Input range 2: ±2, ±20, ±50 V
Resolution @ 15 bit + sign
Nr 8 (4) channels (SPDT relay,
capacity 5A 250 Vac), LED signalling
Nr 2 (1) channels (12 bits resolution, volts/current), voltage (0..5/ 0..10 / 1..5 / 2..10 V), current (0..20 / 4..20 mA)
Nr 2 bistable relay, contact rating: 30 Vdc – 1 A max
(resitive load)
Z-NET configurator
PLC programming (IEC 61131 - Isagraf)
Z-NET RTU (telecontrol)
OPC Server (data exchange)
Web Server (html / java monitoring)
Datalogger / trend
EN50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN
50140/141; EN 61010-1; EN 60742; EN 61000-6-2
Datalogging
SMS free transmission
Data / SMS connections with center unit
Automatic daily log sending
Datalogging
SMS free transmission
Data / SMS connections with centralized unit
Automatic daily log sending
EN61000-6-4/2002; EN6100-6-2/2005; EN61010-1/2001
Lg 186, Lg 791/Dir. 73/23/CEE, D.Lgs.615 12.11.96,
D.Lgs 626 25.11.96, D.Lgs.277 31.07.97, CEI 110-24, CEI
EN 61293, CEI EN 60529, UNI EN 12954, 0950, UNI EN
11094
Page 25
Page 26
ELECTRIC FEATURES
Power supply
10-30 Vdc
Battery Life-Time
Absorption
Protection Degree
7 W min, 15 W max, 11 W (GSM idle)
IP20
THERMOMECANIC FEATURES
Operating Temperature
Dimension
Weight
Enclosure
Connections
-10..+55 °C (reccomended)
185 x 242 x 36,90 mm
875 g
Aluminium
Removable terminals with section of 2.5 mm2
COMMUNICATION, PROCESSING, MEMORY
Communication Ports
Modem
CPU
Memory
1 Ethernet:
1 RS232/RS485 programmable:
1 RS485 Modbus for expansions
1 RS232 Debug/User
1 Internal for connections to modem
Dual band GSM 900/1800 MHz (optional tri-band), full
type approval, GPRS class 8 (optional class 10)
PSTN, ITU-T V.90/ 56 k, ITU-T V.34 enhanced, V.34,
V.32bis, V.32, V.22bis, V22, Bell 212A e 103/113, ITU-T
V.21 & V.23
RISC 32 bit – 20 MIPS
RAM: 8MB
Flash memory (data): 16 MB
SOFTWARE, SIGNALS, MEASUREMENT
System Protocols
Digital Input
Analog Input
Digital Output
Analog Output
FUNCTIONS & SETTINGS
Programming / Mode
Norms
17
Z-TWS-2
Z-TWS-64
Z-LWS
Z-BRIDGE
Muti-function
Control Unit
Muti-function
Control Unit 64 bit
Micro PLC
Bridge TCP/IP
ORDER CODES
Model
Alarms Vocal Card
Profibus DP Slave Interface
Telecontrol Protocols
Software/Accessories
Z-TWS-2
Z-SPEECH
Z-PROFIBUS
IEC 870-101/104
Page 25 / 26
Z-TWS-64
Z-SPEECH
Z-PROFIBUS
IEC 870-101/104
Page 25 / 26
Z-LWS
Z-PROFIBUS
Page 25 / 26
Z-BRIDGE
Page 25 / 26
10..40 Vdc
19..28 Vac / 50-60 Hz
3.5 W
1.500 Vac
Ethernet Connection
Power On
PLC On
Ethernet link
II
2
IP20
0..+55 °C
-20..+70 °C
30..90% a +40 °C (non condensing)
17.5 x 100 x 112 mm
250 g
Nylon 6 with 30% glass-fiber, V0 self-extinguished class
Yes
Removable terminals with section of 2.5
mm2
35 mm symmetrical DIN rail 46277
10..40 Vdc
19..28 Vac / 50-60 Hz
3.5 W
1.500 Vac
Ethernet Connection
Power On
PLC On
Ethernet link
II
2
IP20
0..+55 °C
-20..+70 °C
30..90% a +40 °C (non condensing)
17.5 x 100 x 112 mm
250 g
Nylon 6 with 30% glass-fiber, V0 self-extinguished class
Yes
Removable terminals with section of 2.5
mm2
35 mm symmetrical DIN rail 46277
10..40 Vdc
19..28 Vac / 50-60 Hz
3.5 W
1.500 Vac
Ethernet Connection
Power On
PLC On
Ethernet link
II
2
IP20
0..+55 °C
-20..+70 °C
30..90% a +40 °C (non condensing)
17.5 x 100 x 112 mm
250 g
Nylon 6 with 30% glass-fiber, V0 self-extinguished class
Yes
Removable terminals with section of 2.5
mm2
35 mm symmetrical DIN rail 46277
10..40 Vdc
19..28 Vac / 50-60 Hz
3.5 W
1.500 Vac
Ethernet Connection
Power On
PLC On
1
1
1
1
1
1
1
1
1
1
0
1
1
1
0
1
1
Yes
Client / Server
10 Mb/s
PPP, http, FTP, SMTP
1
1
Client / Server
10 Mb/s
http, FTP
Only Server
10 Mb/s
http, FTP
4
3
Master / Slave
1.200..115.00 bps
None, even, odd
1200 m
32 nodes
Yes
Yes
4
3
Master / Slave
1.200..115.00 bps
None, even, odd
1200 m
32 nodes
Yes
Yes
4
3
Master / Slave
1.200..115.00 bps
None, even, odd
1200 m
32 nodes
-
n.d.
CPU μP MISC 64 bit
16 MB
8 MB
236 bytes
Yes
n.d.
CPU μP RISC 32 bit – 20 MIPS
512 KB
256 KB
236 bytes
Yes
n.d.
CPU μP RISC 32 bit – 20 MIPS
512 KB
256 KB
Yes
Yes
Yes
Yes
Yes
Yes
Yes
32.000
16.000
16.000
EN50081-2; EN 55011; EN 50082-2; EN
61000-2-2/4, EN 50140/141 ; EN 61010-1;
EN 60742
Yes
Yes (limited functions)
n.d.
n.d.
n.d.
EN50081-2; EN 55011; EN 50082-2; EN
61000-2-2/4, EN 50140/141 ; EN 61010-1;
EN 60742
Yes
n.d.
n.d.
n.d.
EN50081-2; EN 55011; EN 50082-2; EN
61000-2-2/4, EN 50140/141 ; EN 61010-1;
EN 60742
INDUSTRIAL I/O’S
AND TELECONTROL
Z-PC LINE • CONTROL UNIT
Installation Category
Pollution Degree
Protection Degree
Operating Temperature
Storage Temperature
Humidity
Dimension
Weight
Enclosure
Hot swapping
Connection
Mounting
II
2
IP20
0..+55 °C
-20..+70 °C
30..90% a +40 °C (non condensing)
17.5 x 100 x 112 mm
250 g
Nylon 6 with 30% glass-fiber, V0 self-extinguished class
Yes
Removable terminals with section of 2.5
mm2
35 mm symmetrical DIN rail 46277
CONVERTERS
AND INTERFACES
GENERAL FEATURES
Dc Power supply
Ac Power supply
Max consumption
Galvanic isolation
Status Indicator
ETHERNET/REMOTE COMMUNICATION
Ethernet 10BaseT Port
Ethernet TCP/IP
ModBUS TCP / IP
Speed (Ethernet)
System Protocols
1
Yes
Client / Server
10 Mb/s
PPP, http, FTP, SMTP
DIGITAL
DISPLAYS
COMMUNICATION PORTS
# 0 RS232 (default system monitoring
or I/O acquisition)
# 1 RS485 default ModBUS Master
I/O or other Modbus RTU devices)
# 2 RS232/485 (programm. via DipSw); I/O Z-PC connection
#3 RS485 (I/O aquisition)
4
3
Master / Slave
1.200..115.00 bps
None, even, odd
1200 m
32 nodes
Yes
Yes
PROCESSING & MEMORIES
Cycle Time
Processing
Flash Memory (Data)
RAM Memory
Retentative Variables
Backup Memory
2.5 ms/K instruction
CPU μP RISC 32 bit – 20 MIPS
16 MB (of which 14 for datalogging)
8 MB
236 bytes
Yes
CONFIGURATION, SOFTWARE, NORMS
Z-NET
OPC SERVER
Web Server
Datalogger
RTU / Z-NET RTU
PLC / ISAGRAF
Max Analog Variables
Max Timers
Max Counters
Norms
Yes
Yes
Yes
Yes
Yes
Yes
32.000
16.000
16.000
EN50081-2; EN 55011; EN 50082-2; EN
61000-2-2/4, EN 50140/141 ; EN 61010-1;
EN 60742
MEASUREMENT
DEVICES
SERIAL/BUS COMMUNICATION
Max task ModBUS Master
Max task ModBUS slave RTU or TCP
ModBUS RTU on RS232/RS485
Speed (Serial)
Parity
Distance Max connection
Max Modules Number
Profibus DP Slave
CanOpen Master
INDUSTRIAL I/OʼS AND TELECONTROL
18
Z-PC-LINE • DIGITAL I/O MODULES WITH MODBUS COMMUNICATION
Z-D-IN
Z-D-OUT
Z-10-D-IN
Z-10-D-OUT
Z-D-IO
5-CH Digital Input
module // RS485
5-CH Digital Output
module // RS485
10-CH Digital Input
module // RS485
10-CH Digital Output
module // RS485
8-CH 6 Digital Input / 2 Digital
Output control module
ORDER CODES
Model
Software
Accessories
Z-D-IN
Page 25
Page 26
Z-D-OUT
Page 25
Page 26
Z-10-D-IN
Page 25
Page 26
Z-10-D-OUT
Page 25
Page 26
Z-D-IO
Page 25
Page 26
ELECTRIC FEATURES
Power supply
Max consumption
Galvanic isolation
Transducer power supply
Status Indicators
Protection Degree
19..40 Vdc / 19..28 Vac / 50-60 Hz 10..40 Vdc / 19..28 Vac / 50-60 Hz 10..40 Vdc, 19..28 Vac 50..60Hz
(9..28 Vdc on demand)
3,5 W
2,5 W
2W
1.500 Vac (3 way)
1.500 Vac (3 way)
1.500 Vac vs (input)
3.750 Vac (output)
Max 20 mA
Power supply, error, data transmis- Power supply, error, data transmis- Power supply, error, data transmis- Power supply, error, data transmis- Power supply, error, data transmission, data reception, input
sion, data reception, output
sion, data reception, input
sion, data reception, output , dia- sion, date reception, input and outgnostic
put
IP20
IP20
IP20
IP20
IP20
19..40 Vdc / 19..28 Vac / 50-60 Hz
(9..28 Vdc on demand)
2,5 W
1.500 Vac (3 way)
19..40 Vdc / 19..28 Vac / 50-60 Hz
(9..28 Vdc on demand)
2,5 W
1.500 Vac (3 way)
THERMOMECHANIC FEATURES
Operating Temperature
Dimension
Weight
Enclosure
Connections
Mounting
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw terminals, plug in
connectors, 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw terminals, plug in
connectors, 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw terminals, plug in
connectors, 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw terminals, plug in
connectors, 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 150 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw terminals, plug in
connectors, 2.5 mm2
35 mm symmetrical DIN rail 46277
RS485 2 wires
Up to 57.600 bps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM for the configuration
parameters, retention time 10
years
RS485 2 wires
Up to 57.600 bps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM for the configuration
parameters, retention time 10
years
RS485 2 wires
Up to 57.600 bps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM for the configuration
parametres, retention time 10
years
RS485 2 wires
Up to 115.200 bps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
10
Input protection by 600W/ms TVS
transient current suppressers
8 inputs with 16 bit contactor with
100 Hz max. frequency.
2 inputs with 32 bit contactor with
10 kHz max. frequency.
10
MOSFET outputs protected
against short circuit with shared
negative pole
6 - 40 Vdc power supply, current
carrying capacity 0.5A, resistive
load 0.5A inductive load
Safety time: from 10 ms to 2000 s.
Measurement of the load supply
voltage
6 input, 2 output
Nr 6 opto-isolated digital inputs:
REED, proximity, PNP, NPN, contact, etc.
Internal / external input power
supply, min pulse width 20 ms
Nr 2 SPST relay output with common contact, capacity 5A 250Vac,
contact NA / NC
Frequency measurement for 10
kHz inputs
Period, frequency and Ton, Toff
measurement for 100 Hz inputs
Forward or backward counting
Overflow indication for each total
counter
Diagnostics on/off, overload, shortcircuit
Fail-safe programmable functions
COMMUNICATION, MEMORY PROCESS
Interface
Speed
Protocol
Communication Time
Distance
Connectivity
Data Memory
RS485 2 wires
Up to 57.600 bps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM for the configuration
parameters, retention time 10
years, N° 5 registers 16 bit, N° 5
bit overflow
SIGNALS, MEASUREMENT, CONFIGURATIONS, NORMS
Channel Numbers
Type
5
Opto-isolated for REED, PROXIMITY, PNP, NPN, contact, etc.
Nr 4 input with countering function
16 bit, max frequency 100 Hz
Nr 1 input with countering function
16 bit, max frequency 10 kHz
Bounce Filter 5..250 ms
5
SPST N/O relay output module, 5
A @ 250 Vac with resistive load, 2
A @ 250 Vac with inductive load
Max total current on terminal: 12 A
Measure & Diagnostic
Programming
• Z-NET3 (software)
• DIP switch
• Z-NET3 (software)
• DIP switch
• Z-NET3 (software)
• DIP switch
• Z-NET3 (software)
• DIP switch
•Z-NET3 (software)
DIP switch
Local/Remote Functioning Mode
Internal Logic IEC1131.2 type 1
for motor, valves and alarms
command
Norms & Approvals
RINA, CE, EN 50081-2; EN
55011; EN 50082-2; EN 61000-22/4; EN 50140/141; EN 61010-1
RINA, CE, EN 50081-2; EN
55011; EN 50082-2; EN 61000-22/4; EN 50140/141; EN 61010-1
UL-UR, RINA, CE, EN 50081-2;
EN 55011; EN 50082-2; EN
61000-2-2/4; EN 50140/141; EN
61010-1
UL-UR, RINA, CE, EN 50081-2;
EN 55011; EN 50082-2; EN
61000-2-2/4; EN 50140/141; EN
61010-1
RINA, CE, EN61000-6-4/2002;
EN61000-6-2/2002; EN61010-1
19
Z-8AI
Z-3AO
1-CH Universal Input
module // RS485
2-CH Analog I/O module
+ PID control // RS485
4-CH Analog Input
module // RS485
8-CH Analog Input
module // RS485
3-CH Analog Output
module // RS485
ORDER CODES
Model
Software
Accessories
Z-DAQ
Page 25
Page 26
Z-PID
Page 25
Page 26
Z-4AI
Page 25
Page 26
Z-8AI
Page 25
Page 26
Z-3AO
Page 25
Page 26
19..40 Vdc / 19..28 Vac / 50-60 Hz
(9..28 Vdc on demand)
2,5 W
1.500 Vac (3 way)
Min 18 Vdc, 20 mA
Power supply, error, data transmission, data reception
IP20
19..40 Vdc / 19..28 Vac / 50-60 Hz
(9..28 Vdc on demand)
2,5 W
1.500 Vac (3 way)
Min 18 Vdc, 20 mA
Power supply, error, data transmission, data reception
IP20
19..40 Vdc / 19..28 Vac / 50-60 Hz
(9..28 Vdc on demand)
2,5 W
1.500 Vac (3 way)
20 Vdc, 40 mA (up to 2 sensors)
Power supply, error, data transmission, data reception
IP20
10..40 Vdc / 19..28 Vac / 50-60 Hz 10..40 Vdc / 19..28 Vac / 50-60 Hz
0,5 W
1500 Vac (6 way)
Power supply, error, data transmission, data reception
IP20
3,2 W
1500 Vac
Power supply, error, data transmission, data reception
IP20
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw clamp, plug in connectors,
max 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw clamp, plug in connectors,
max 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+60 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw clamp, plug in connectors,
max 2.5 mm2
35 mm symmetrical DIN rail 46277
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw clamp, plug in connectors,
max 2.5 mm2
35 mm symmetrical DIN rail 46277
RS485 2 wires
RS232 (DB9 Jack stereo 3.5 mm)
Up to 57.600 bps (RS485)
2.400 bps (RS232)
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Fino a 1.200 m
Max 32 nodi
EEPROM configuration parametres, retention time 10 years
RS485 2 wires
RS232 (DB9 Jack stereo 3.5 mm)
Up to a 57.600 bps (RS485)
2.400 bps (RS232)
ModBUS RTU slave
< 20 ms (@ 38400 baud)
Fino a 1.200 m
Max 32 nodi
EEPROM configuration parametres, retention time 10 years
Up to 8
Nr 4 differential mode input, max
input voltage 20 Vdc, impedance
200 KΩ
Nr 8 'single-ended' mode input,
impedance 100 KΩ
Range: ± 2.5 Vdc, ± 5 Vdc, ± 10
Vdc
3 (actives)
Nr 3 output in current 0..20 / 4..20
mA (driven impedance < 500 Ω),
1 output convertable in voltage:
0..10 / 2..10 Vdc (driven impedance > 500 Ω)
ELECTRIC FEATURES
Power supply
Max Absorption
Galvanic isolation
Transducer Power Supply
Status Indicator
Protection Degree
THERMOMECANIC FEATURES
Operating Temperature
Dimension
Weight
Enclosure
Connections
Mounting
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fiber, V0
self-extinguished class
Screw clamp, plug in connectors,
max 2.5 mm2
35 mm symmetrical DIN rail 46277
COMMUNICATION, MEMORY PROCESS
Interface
RS485 2 wires
RS485 2 wires
RS485 2 wires
Speed
Up to 57.600 bps
Up to 57.600 bps
Up to 57.600 bps
Protocol
Communication Time
Distance
Connectivity
Data Memory
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Fino a 1.200 m
Max 32 nodi
EEPROM configuration parametres, retention time 10 years
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Fino a 1.200 m
Max 32 nodi
EEPROM configuration parametres, retention time 10 years
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Fino a 1.200 m
Max 32 nodi
EEPROM configuration parametres, retention time 10 years
SIGNALS, MEASUREMENT, CONFIGURATIONS, NORMS
Channel Numbers
Type
1 (programmable)
Thermocouple: J (-200..+1000 °C),
K (-200..+1300 °C), R (-50..+1750
°C), S (-50..+1750 °C), T (-200..+
400 °C), E (-150..+800 °C), B
(0..+1800 °C), N (-200..+1300 °C)
Thermoresistance: Pt100: 200..+600 °C; Ni100: -60..+180 °C
Potenziometer:
0..3.5 kΩ; 0..8.7 kΩ; 0..15 kΩ
Voltage (bipolar): 0..50 mV; 0..200
mV; 0..2 V; 0..5 V; 0..10 V
Current (bipolar): 0..20 mA
Resolution
Accuracy
13 bit + sign
< 0,2% d.l.
Thermal stability
Programming
Norms & Approvals
1 input, 1 output
Input:
Thermocouple: J (-200..+1000 °C),
K (-200..+1300 °C), R (-50..+1750
°C), S (-50..+1750 °C), T (-200..+
400 °C), E (-150..+800 °C), B
(0..+1800 °C), N (-200..+1300 °C)
Thermoresistance: Pt100: 200..+600 °C; Ni100: -60..+180 °C
Potenziometer:
0..3.5 kΩ; 0..8.7 kΩ; 0..15 kΩ
Voltage (bipolar): 0..50 mV; 0..200
mV; 0..2 V; 0..5 V; 0..10 V
Current (bipolar): 0..20 mA
Output Current 0/4..20 mA
13 bit + sign
< 0,2% d.l.
4 (2 actives)
Voltage(bipolar): ±2, ±10 Vdc,
impedance 100 Ω
Current: (bipolar): ± 20 mA, impedance 100 Ω
Selectable from 11 to 15 bit + sign
0,1% (voltage)
0,2% (current)
< 0,02%/°C
< 0,02%/°C
0,02%
Z-NET3 (software)
Z-NET3 (software)
Z-NET3 (software)
DIP switch
DIP switch
DIP switch
RINA, CE, EN50081-2, EN 55011, RINA, CE, EN50081-2, EN 55011, RINA, CE, EN50081-2, EN 55011,
EN 50082-2, EN 61000-2-2/4, EN EN 50082-2, EN 61000-2-2/4, EN EN 50082-2, EN 61000-2-2/4, EN
50140/141, EN 61010-1
50140/141, EN 61010-1
50140/141, EN 61010-1
Selectable from 11 to 15 bit + sign 12 bit
0.1% full scale
<0.2% (current)
<0.3% (voltage)
0.01%/°
Z-NET3 (software)
Z-NET3 (software)
DIP switch
DIP switch
UL-UR, RINA, CE, EN50081-2,
UL-UR, RINA, CE, EN50081-2,
EN 55011, EN 50082-2, EN
EN 55011, EN 50082-2, EN
61000-2-2/4, EN 50140/141, EN 61000-2-2/4, EN 50140/141, EN
61010-1, EN 60742
61010-1, EN 60742
CONVERTERS
AND INTERFACES
Z-4AI
DIGITAL
DISPLAYS
Z-PID
MEASUREMENT
DEVICES
Z-DAQ
INDUSTRIAL I/O’S
AND TELECONTROL
Z-PC-LINE • ANALOG I/O MODULES WITH MODBUS COMMUNICATION
INDUSTRIAL I/OʼS AND TELECONTROL
20
Z-PC LINE • TEMPERATURE CONTROL MODULES WITH MODBUS COMMUNICATION
Z-4RTD-2
Z-4TC
4-CH RTD
Input module // RS485
Z-8TC
4-CH Thermocouple
input module // RS485
8-CH Thermocouple
Input module // RS485
ORDER CODES
Model
Software
Accessories
Z-4RTD-2
Page 25
Page 26
Z-4TC
Page 25
Page 26
Z-8TC
Page 25
Page 26
10..40 Vdc, 19..28 Vac 50..60 Hz
0,7 W
1.500 Vac (3 way)
Power supply,
Error,
Data transmission,
Data receiving
IP20
19..40 Vdc / 19..28 Vac / 50-60 Hz (9..28 Vdc on demand)
Max 2.5 W; 1.6 W @ 24 Vdc
1.500 Vac (3 way)
Power supply,
Error,
Data transmission,
Data Receiving
IP20
10..40 Vdc; 19..28 Vac (50-60 Hz) bus powered
0,6 W
1.500 Vac (6 way)
Power supply,
Error,
RS485 communication
ELECTRIC FEATURES
Power supply
Max Absorption
Galvanic isolation
Status Indicator
Protection Degree
IP20
THERMOMECHANIC FEATURES
Operating Temperature
Dimension
Weight
Enclosure
Connections
-10..+65 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extinguished class
Screw clamp, plug in connectors, max 2.5 mm2
Rear IDC10 connector for DIN rail 3.5 mm stereophonic
front jack for RS232 (COM) connection
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extinguished class
Screw clamp, plug in connectors, max 2,5 mm2
Rear IDC10 connector for DIN rail 3.5 mm stereophonic
front jack for RS232 (COM) connection
-10..+65 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extinguished class
Screw clamp, plug in connectors, max 2,5 mm2
Rear IDC10 connector for DIN rail 3.5 mm stereophonic
front jack for RS232 (COM) connection
Mounting
35 mm symmetrical DIN rail 46277
35 mm symmetrical DIN rail 46277
35 mm symmetrical DIN rail 46277
2 wire RS485
2 wire RS485
RS232, front jack, speed 2400 Baud, data bits 8, Parity:
NO, Stop bits:1
Up to 115 kbps
ModBUS RTU slave
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters, retention time 10
years
COMMUNICATION, MEMORY, PROCESS
Interface
Speed
Protocol
Communication Time
Distance
Connectivity
Data storage
2 wire RS485
RS232, front jack, speed 2400 Baud, data bits 8, Parity:
NO, Stop bits:1
Up to 115 kbps
ModBUS RTU slave
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters, retention time 40
years
Up to 57.600 bps
ModBUS RTU slave
< 20 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters, retention time 10
years
SIGNALS, MEASUREMENT, CONFIGURATIONS, NORMS
Channel Numbers
Type
Resolution
Accuracy
Thermal drif
Programming
Norms & Approvals
4
4 clamps (ohmeter 2,3,4 wire)
Pt100: -200..+650°C (f.s. 330 Ω)
Pt500: -200..+750°C (f.s 1.800 Ω )
Pt1000: -200..+210°C (f.s. 1.800 Ω)
Ni100: -60..+250°C (f.s. 330 Ω)
14 bit
0,05%
25 ppm/K
Software (Z-NET3): online settings parameters via serial
(RS485-bus and/or RS 232-jack) or Ethernet
DIP switch
UL-UR, RINA, CE, EN 61000-6-4/2002, EN 61000-62/2002, EN 61010, EN 60742
4
Bipolar Voltage ± 80 mVdc, impedance 10 MΩ
Thermocouple J, K, R, S, T. B, E, N
8
Thermocouple J, K, R, S, T. B, E, N (EN 60584-1, ITS-90)
Range: -210..1820 °C
Span mV: -10,1..81,4 mV
Shunt up to 70 mW
13 bit+sign
0,1%
0,01%/°C c.d.m.
Software (Z-NET3): online settings parameters via serial
(RS485-bus and/or RS 232-jack) or Ethernet
DIP switch
RINA, CE, EN50081-2, EN 55011, EN 50082-2,
EN 61000-2-2/4, EN 50140/141, EN 61010-1, EN 60742
16 bit
0,05%
< 100 ppm/K
Software (Z-NET3): online settings parameters via serial
(RS485-bus and/or RS 232-jack) or Ethernet
DIP switch
CE, EN 61000-6-4/2002, EN 61000-6-2/2002, EN 61010,
EN 60742
21
Z-SG
Z203
S203T / S203TA
Z-SPEECH
Strain gauge input
module // RS485
Single phase network
analyzer // RS485
Advanced 3-phase network analyzer // RS485
Speech
Alarm Module
ORDER CODES
Model
Z-SG
Z203
Software
Accessories
Page 25
Page 26
Page 25
Page 26
Power supply
10..40 Vdc, 19..28 Vac 50..60 Hz
10..40 Vdc / 19..28 Vac / 50-60 Hz
Max Absorption
Galvanic isolation
2,5 W
1.500 Vac (3 way)
S203T (input 100 mA)
S203TA (input 5 Arms)
Page 25
Page 26
TA15 (per S203T f.s. 15 A, prec. 0,1%)
TA25 (per S203T f.s. 25 A, prec. 0,1%)
TA100 (per S203T f.s. 100 A, prec. 0,1%)
Z-SPEECH
Page 25
Page 26
INDUSTRIAL I/O’S
AND TELECONTROL
Z-PC LINE • SPECIAL MODULES
Status Indicator
Protection Degree
2W
3.750 Vac (from/to power)
1500 Vac (other circuits)
Power supply, error, data transmission, data Power supply, error, data transmission, data
receiving
receiving
IP20
10..40 Vdc; 19..28 Vac (50-60 Hz),
9 Vac – 12 Vdc 100 mA
bus powered
2,5 W
3.750 Vac (from/to power)
1500 Vac (other circuits)
Power supply, error, RS485 communication
IP20
IP20
IP20
-10..+65 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extinguished class
Screw-fit removable terminals for wires up
to 2.5 mm2
IDC10 Back connector for DIN rail frontal
Jack RS232 (ModBUS)
-10..+65 °C
105 x 89 x 60 mm
About 140 g
Plastic Material UL V0
0..+55 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extingusihed class
Screw-fit removable terminals for wires up
to 2.5 mm2
Rear IDC10 connector for DIN rail
35 mm symmetrical DIN rail 46277
35 mm symmetrical DIN rail 46277
35 mm symmetrical DIN rail 46277
2 wire RS485
RS232, front jack, speed 2400 Baud, data
bits 8, Parity: NO, Stop bits:1
Up to 115 kbps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters,
retention time 10 years
2 wire RS485
RS232, front jack, speed 2400 Baud, data
bits 8, Parity: NO, Stop bits:1
Refresh every 25 ms
ModBUS RTU slave
V4 / RS232, 1.200..19.200 bps
Analogic: 4 wires, 600 Ω, configurables
levels
THERMOMECANIC FEATURES
Operating Temperature
Dimension
Weight
Enclosure
Connections
Mounting
-10..+65 °C
17.5 x 100 x 112 mm
About 140 g
Nylon 6 with 30% glass-fibre, V0 self-extinguished class
Screw-fit removable terminals for wires up
to 2.5 mm2
IDC10 Back connector for DIN rail frontal
Jack RS232 (ModBUS) (COM)
connection
35 mm symmetrical DIN rail 46277
Screw terminals, step 5,08 mm
CONVERTERS
AND INTERFACES
ELECTRIC FEATURES
Speed
Protocol
Communication Time
Distance
Connectivity
Data Memory
2 wires RS485
RS232, front jack, speed 2400 Baud, data
bits 8, Parity: NO, Stop bits:1
Up to 115 kbps
ModBUS RTU slave
< 10 ms (@ 38400 baud)
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters,
retention time 40 years
Up to 1.200 m
Max 32 nodes
EEPROM configuration parameters,
retention time 10 years
DIGITAL
DISPLAYS
COMMUNICATION, MEMORY PROCESS
Interface
Resolution
Accuracy
Stability
Programming
Norms & Approvals
2 input, 2 output
Input: 1 analog channel for load cell (and
Power supply) up to 4 (350 Ω) or 8 (1.000 Ω)
6-wires or 4-wires differential measurement
input, impedance equeal to 87 Ω
Output: 1 retransmission analog channel of
the net weight in current (0..20, 4..20 mA)
Or in voltage (0..5, 0..10 V)
1 Digital Input or Output fore calibration tare
or weight limit
Sensibility from 1 to 64 mV/V
Up to 24 bit
0,01%
25 ppm/K
Software (Z-NET3): online parameters settings via serial
(RS485-bus and/or RS
232-jack) or Ethernet
DIP switch
1 input, 1 output
Input voltage: 0..500 Vac, 41 scales, ferquency 10 Hz..1kHz
Output voltage (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
Output current (mA)
2 scales: 0/4..20 mA
Analog retransmission of : Vrms, Irms, P, Q,
cosФ
1 input, 1 output
Input voltage: up to 600 Vac, frequency 50 60 Hz
Input current: fino a 100 mA (S203T),
5 Arms (S203TA)
Measured values (single / triple phase):
Vrms, Irms, P, Q, S, frequancy, Cosϕ,
Energy
Re-transmited analog output: voltage / current
0,5% (V, A. W)
Software (Z-NET3): online parameters settings via serial
or Ethernet
DIP switch
0,2%
Software (Z-NET3): online parameters settings via serial
or Ethernet
DIP switch
CE, EN 61000-6-4/2002, EN 61000-62/2002, EN 61010, EN 60742, IEC 61131
UL-UR, CE, EN50081-2, EN 55011, EN
50082-2, EN 61000-2-2/4, EN 50140/141,
EN 61010-1, EN 60742
CE, EN 61000-6-4/2002, EN 61000-62/2002, EN 61010, EN 60742
Microphone input
Recording memory: 4 min
Nr max messages: 15
Nr max phone numbers: 12
DTMF receiver
Single alarm linking
CE, EN 61000-6-4, EN 61000-6-2, EN
61010-1, EN 60742
MEASUREMENT
DEVICES
SIGNALS, MEASUREMENT, CONFIGURATIONS, NORMS
Channel Numbers
Type
INDUSTRIAL I/OʼS AND TELECONTROL
22
Z-PC LINE • COMMUNICATION MODULES
Z-PROFIBUS
Z107 / S107P
K107USB / S107USB
Z-LINK / S-LINK
Profibus DP Slave
interface
RS232 – RS485/422
serial converter
RS485/USB asynchronous
serial converter
Radio transceiver
module (portable/desk)
ORDER CODES
Model
Z-PROFIBUS
Z107
S107P (portable version)
K107USB
S107USB (portable version)
K-BUS (expandable 2 slot connector)
K-SUPPLY (redundant power supply module)
Page 25
K-BUS (page 34)
K-SUPPLY (page 34)
Z-LINK-434MHz Z-LINK-869MHz
S-LINK-434MHz (desk version)
S-LINK-869MHz (desk version)
A-LINK-434 MHz (external antenna)
A-LINK-869MHz (external antenna)
A-DIR-434MHz (directional antenna)
A-DIR-869MHz (directional antenna)
Software and Accessories
Page 25 / Page 26
Page 25 / Page 26
Power supply
10..40 Vdc, 19..28 Vac 50..60 Hz (form
screw on IDC10 bus )
Z107: 10..40 Vdc, 19..28 Vac 50..60 Hz
S107P: 9..12 Vdc (with feeder 220 Vac)
By USB PC port
Z107: 2,5 W
S107P: 1 W
1.500 Vac (3 way)
60 mA
Z-LINK: 10..18 / 21,5..28 Vdc; 8,5..14 / 17..20
Vac (50-60 Hz)
S-LINK: by power supply 230 Vac
Z-LINK: 1,5 W
S-LINK: 2,5 W
1.500 Vac
Max Absorption
4W
Galvanic isolation
Status Indicator
1.500 Vac per 1 minute
250 Vac continue
Power supply, error
Power supply, RST signal status, data
transmission, data reception
K107USB: data, reversed connection,
Power supply, error, data transmission, data
power supply
reception
S107USB: power supply, data transmission,
data reception
IP20
IP20
Protection Degree
IP20
ELECTRIC FEATURES
IP20
1.500 Vac
THERMOMECANIC FEATURES
Operating Temperature
0..+55 °C
0..+55°C
17.5 x 100 x 112 mm
17,5 x 100 x 112 mm
Weight
About 140 g
Z-LINK: 17,5 x 100 x 112 mm
S-LINK: 25 x 68 x 125 mm
About 200 g
Enclosure
PBT
Connections
Profibus DB9-F
TP-Wire
IDC10Back Connector for DIN rail
K107USB: -20..+65°C
S107USB: 0..+55°C
K107USB: 6,2 x 93,1 x 102,5 mm
S107USB: 40 x 48 x 20,17 mm
About 200 g
K107USB: 45 g
S107USB: 24 g
Z107: Nylon 6 with 30% glass-fibre, V0 self- K107USB: PBT
extinguished class
S107USB: ABS
S107P: ABS
Z107: Screw-fit removable terminals for
K107USB: spring clamp
wires up to 2.5 mm2
S107USB: plug-in terminal block 5 p
0..+55°C
Dimension
Mounting
35 mm symmetrical DIN rail 46277
Z107: 35 mm symmetrical DIN rail 46277
K107USB: 35 mm symmetrical DIN rail 46277
Z-LINK: 35 mm symmetrical DIN rail 46277
Z107
RS232 on RJ45 frontal connector
RS485/RS422, removable screw clamp
with screw type connection
S107P
RS232, DB9 connector
RS485/RA422, extractable clamps 5 poles
Screw connection
2 wires Half Duplex, point to point, multidrop
Automatic timing, command from
RTS on RS232 interface
Up to 115 kbps
ModBUS RTU slave
Up to 1.200 m
K107USB
RS485, 31 nodes, cage clamp
S107USB
RS485, terminal and speed (from 1.200 bps
to 250 kbps)
USB interface 1.0 e 2.0, USB A e MINI
USB B connectors, multiple connection
On the same PC
Cage clamp
Automatic timing
RS232
RS485
Up to 250 kbps
ModBUS RTU slave
Up to 1.200 m
100 Kbps (data interface) / 9.600 bps (radio)
434 (869) MHz
10 mW
ModBUS RTU
100 m (suggested) up to 1 km in open field
lacking of obstacles with directive antenna
DIP switch (speed, communication,
direction change)
RINA, CE, EN 50081-2, EN 55011, EN
50082-2, EN 61000-2-2/4, EN 50140/141,
EN 61010-1, EN 60742
Cd con driver, USB connection cable
DIP switch (communication parametres)
Programmable Flash for other protocols
CE; EN50081-2; EN 55011; EN 50082-2;
EN 61000-2-2/4; EN 50140/141; EN 610101; EN 60742; ETSI 300-328
Z-LINK: Nylon 6 with 30% glass-fibre, V0
self-extinguished class
S-LINK: ABS
Z-LINK: Hand vice clamp for conductors up
to 2.5 mm2
S-LINK: Cable 2.5 mm2 / DB9-F connector
COMMUNICATION, MEMORY PROCESS
Interface
Profibus DP-Slave, speed from 9.600 bps
to 12.000 kbps
TP-Wire master, daisy chain connection,
line drive max 485
Operating ways
Direction change
Speed
Frequency
Emitted Power
Protocol
Distance
Half Duplex
Automatic timing
CONFIGURATIONS, NORMS
Programming
Isagraf block data exchange
Norms & Approvals
CE, EN 61000-6-4, EN 61000-6-2, EN
61010-1, EN 60742
UL-UR, CE, EN 61010-1, EN 60742, EN
61000-6-2, EN 61000-6-4
23
Z-PC-LINE • DIGITAL I/O MODULES WITH CANOPEN COMMUNICATION
24-CH Digital Input
CANopen module
24-CH Digital Output
CANopen module
ZC-16DI-8DO
24-CH, 16 Digital Input / 8 Digital
Output, CANopen module
ORDERS CODES
Model
Software
Accessories
ZC-24-DI
Page 25
Page 26
ZC-24-DO
Page 25
Page 26
ZC-16DI-8DO
Page 25
Page 26
10..40 Vdc; 19..28 Vac
2,5 W
1,5 kVac (3 way)
2,5 ms
-10..+65 °C
35 x 100 x 112 mm
10..40 Vdc; 19..28 Vac
2,5 W
1,5 kVac (3 way)
1,2 ms
-10..+65 °C
35 x 100 x 112 mm
10..40 Vdc; 19..28 Vac
2,5 W
1,5 kVac (3 way)
1,2..2,5 ms
-10..+65 °C
35 x 100 x 112 mm
GENERAL DATA
Power supply
Max consumption
Power transducers
Galvanic isolation
Response time
Accuracy
Resolution
Operating temperature
Dimension (w x h x d)
INPUT DATA
Nr channels
Type
24
Polarity (EN 61131-2 type 2) Sink (pnp)
32 bit counters
Vmax 30 V
Minimum pulse width 250 μs
ON/OFF delay < 3ms
Maximum Counters Frequency 10 kHz
16
Polarity (EN 61131-2 type 2) Sink (pnp)
32 bit counters
Vmax 30 V
Minimum pulse width 250 μs
ON/OFF delay < 3ms
Maximum Counters Frequency 10 kHz
INDUSTRIAL I/O’S
AND TELECONTROL
ZC-24-DO
CONVERTERS
AND INTERFACES
ZC-24-DI
OUTPUT DATA
Nr channels
Type
24
Mosfet
Power supply voltage 5-30 Vdc
RDS on 0,75 Ω
ON/off delay 1 ms
8
Mosfet
Power supply voltage 5-30 Vdc
RDS on 0,75 Ω
ON/off delay 1 ms
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic), Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic), Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
MEASUREMENT
DEVICES
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic), Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
DIGITAL
DISPLAYS
CANOPEN FEATURES
NMT
Error control
Node ID
Nr PDO
PDO modes
PDO linking
PDO mapping
Nr SDO server
Emergency message
Supported application layer
Supported profile
INDUSTRIAL I/OʼS AND TELECONTROL
24
Z-PC-LINE • DIGITAL I/O MODULES WITH CANOPEN COMMUNICATION
ZC-8AI
ZC-3AO
ZC-4RTD
8-CH Analog Input
CANopen module
8-CH Analog Output
CANopen module
4-CH RTD Input
CANopen module
ZC-8TC
ZC-SG
8-CH Thermocouple 1-CH Strain Gauge
Input CANopen
Input CANopen
module
module
ORDERS CODES
ZC-8AI
Pag. 25
Pag. 26
ZC-3AO
Pag. 25
Pag. 26
ZC-4RTD
Pag. 25
Pag. 26
ZC-8TC
Pag. 25
Pag. 26
ZC-SG
Pag. 25
Pag. 26
Power supply
Max consumption
Power transducers
10..40 Vdc; 19..28 Vac
5W
22 mA, 8 sensors
10..40 Vdc; 19..28 Vac
2,5 W
10..40 Vdc; 19..28 Vac
1W
10..40 Vdc; 19..28 Vac
1W
Galvanic isolation
Response time
Accuracy
Resolution
Operating temperature
Dimension (w x h x d)
1,5 kVac (6 way)
< 28 ms
0,05%
15 bit
-10..+65°C
17,5 x 100 x 112 mm
1,5 kVac (5 way)
< 7 ms
0,05%
14 bit
-10..+65°C
17,5 x 100 x 112 mm
1,5 kVac (6 way)
< 28 ms
0,05%
14 bit
-10..+65°C
17,5 x 100 x 112 mm
1,5 kVac (6 way)
< 28 ms
0,1%
15 bit
-10..+65°C
17,5 x 100 x 112 mm
10..40 Vdc; 19..28 Vac
1W
5 Vdc, up to 4 / 8 strain gauge
load cells
1,5 kVac (3 way)
< 7 ms
0,01%
24 bit
-10..+65°C
17,5 x 100 x 112 mm
4
PT100 (EN 60751/A2-ITS90)
Range: -200..+650°C
PT500 (EN 60751/A2-ITS90)
Range: -200..+750°C
PT1000 (EN 60751/A2-ITS90)
Range: -200..+210°C
Ni100 (EN 60751/A2-ITS90)
Range: -60..+250°C
Configurable fault
8
THERMOCOUPLE
Type: J, K, E, N, S, R, B, T
Tables EN 60584-1 (ITS 90)
Span: -10,1..81,4 mV
Impedance 10 MΩ
Configurable fault
Model
Software
Accessories
GENERAL DATA
INPUT DATA
Nr channels
Type
8
Voltage range: ±10 V
Current range: 0..20, 4..20 mA
2,3 wires sensor connection
Configurable fault
2
ANALOG
Load cells (strain gauge), Voltage
supply 5 Vdc
Min impedence 87 Ω
4 or 6 –wire bridge connections
Sensitivity from 1 to 64 mV
Full scale: 5..320 mV
DIGITAL
Tare calibration and span (max 30 V)
OUTPUT DATA
3
Voltage range: ±10 V
Current range:
0..20, 4..20 mA
Bipolar output signals
Configurable fault
Nr channels
Type
2
ANALOG
Nr 1 channel: current: 0..20, 4..20
mA or voltage 0..5, 0..10 Vdc
Max error 0,1%,
Response time 5 ms
DIGITAL
Nr 1 channel for stable weight or
threshold (max 30 V, 50 mA)
CANOPEN FEATURES
NMT
Error control
Node ID
Nr PDO
PDO modes
PDO linking
PDO mapping
Nr SDO server
Emergency message
Supported application layer
Supported profile
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic),
Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic),
Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic),
Synq (acyclic)
yes
variable
1
Sì
CiA 301 v 4.02
CiA 401 v 2.01
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic),
Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
Slave
Node guarding
Software, DIP switch
RX 5
Event triggered, Synq (cyclic),
Synq (acyclic)
yes
variable
1
yes
CiA 301 v4.02
CiA 401 v2.01
25
Z-PC LINE • SOFTWARE
Z-NET3
I/O modules software configuration
EC 61131 Z-PC system configurator
Configuration and test: I/O slave modules and A/D
converters (Z-4AI-D, Z-4TC-D)
Communication via PC: Through serial interface
Operating system: Windows 95, 98, ME, 2000, XP,
Vista
Settings: COM Port, baud rate, address, filter, burnout, measurement scale, root extraction etc.
Special Functions: thermocouple calibration, automatic detecting of connected devices, warning
Configuration: Project, CPU, I/O modules, variables, communication network
Automation Functions: Pumps rotation, operating hours meter, counter, flow calculation
Telecontrol Functions: Alarms management / events via SMS, status request via SMS,
SMS commands, log file management via e-mail, log file management via ftp, call on alarm
Additional Tools: Web Editor, Data
ORDER CODES
Code
Tool
Versions
Z-NET2
Z-NET3
Z-NETIO
Extensions
ORDER CODES
I/O modules software configuration
Z-SMS DATA STORE
M-RTU communication software manager
• Supported Versions Z-TWS 64, ZTWS-02,
Z-RTU light and full version
• Basic object insertion (text and images)
• SENECA Tools, integrated with I/O modules
• Basic (label, images) and advanced (trend,
plot, led etc.) graph control
• SMS receiving
• Local / remote data download
• Automatic calls management
• Management, creation and files updating
ORDER CODES
Development Environment for Hmtl / Java web pages editing
Z-SMS DATA STORE
Software of data and M-RTU Communication management
Z-NET2 RTU
OPC SERVER
Data manager software for telecontrol systems
Data exchange software client / server
Configurator Module: RTU Connection Parameters
Runtime Module: Periodical Scheduling for the data download and RAS connections management through OPC server activation
Viewer Module: Alarms and trend Visualization e trend through OCX technology
OPC-SERVER-D: OPC Server demo (functioning for 30')
OPC-SERVER: OPC Server Z-TWS. standard version for remote units connections and data download. Data Exchange through web service / cgi
OPC-SERVER I/O: Support for ModBUS RTU slave or ModBUS TCP protocols supported, PC
ModBUS Master, GPRS TIM and WIND connections, versions from 100, 500 and illimited tag
OPC-SERVER MB: ModBUS RTU slave or ModBUS TCP protocols supported, slave instrumentations simulation, GPRS Vodafone connections, versions from 100, 500 and illimited tag
ORDER CODES
ORDER CODES
Code
Tool
Versions
Description
Data management and telecontrol software
Basic Functions
Basic Functions + exportable OCX
Basic Functions + exportable OCX + automatic download up to 5 RTU
Basic Functions + exportable OCX + automatic download from 6 to 10 RTU
Basic Functions + exportable OCX + automatic download more than 10 RTU
OCX Class objects exportable ActiveX for visualizations
Z-NET2-RTU
-0
-1
-2
-3
-4
Option
OCX
Code
Versions
OPC-SERVER-D
OPC-SERVER
OPC-SERVER I/O-1
OPC-SERVER I/O-2
OPC-SERVER I/O-3
OPC-SERVER MB-1
OPC-SERVER MB-2
OPC-SERVER MB-3
DATA RECORDER
Description
OPC Server demo (30’)
OPC Server Z-TWS (standard)
OPC Server I/O 100 tag
OPC Server I/O 500 tag
OPC Server I/O tag illimited
OPC Server ModBUS Slave 100 tag
OPC Server ModBUS Slave 500 tag
OPC Server ModBUS Slave tag illimited
Z-CALCULUS
Data acquisition, visualization and recording software
OPC client-based power consumption software
ORDER CODES
• Detailed Analysis of relevated and calculated data
• Power costs calculation
• Energy management planning
• Industrial consumptions detection and
accounting
Code
Tool
Version
Options
DR
-2
-4
-8
-16
-32
-64
-M
-A
-R
-MC
Description
Data acquisition software integrated in Z-NET3
2 recordable channels (video tracks)
4 recordable channels (video tracks)
8 recordable channels (video tracks)
16 recordable channels (video tracks)
32 recordable channels (video tracks)
64 recordable channels (video tracks)
Math (calculated channels) tool
Alarm (output activation) tool
Report tool
Multi-client tool
ORDER CODES
Z-CALCULUS
DIGITAL
DISPLAYS
ORDER CODES
WEB EDITOR
CONVERTERS
AND INTERFACES
Web Editor
Development Environment for Hmtl / Java web pages editing
OPC client-based power consumption software
MEASUREMENT
DEVICES
Z-PROG
Description
Software of Z-PC Systems Configuration for CPU 2005-2006
Software of Z-PC Systems Configuration for CPU producted since 2007
Software of I/O slave modules Configuration,
ModBUS Master S401 project Data Recorder
Z-NET2-RTU Telecontrol tool
OPC
OPC - OPC stand alone
Isagraf
Isagraf – PLC programming toolkit.
Data Recorder Data acquisition tool.
INDUSTRIAL I/O’S
AND TELECONTROL
Z-PROG
INDUSTRIAL I/OʼS AND TELECONTROL
26
Z-PC LINE • SOFTWARE AND ACCESSORIES
ISAGRAF
CODESYS
IEC 61131-3 Programming tool
IEC 61131-3 Programming tool
Standard: IEC 61131-3
Programming languages: SFC, FBD,LD,
ST, IL, FC, text
Communication functions: ftp client management, outgoing e-mail , remote connections, incoming and outgoing SMS
Tag licence: 64, 256
• CANopen Master configuration
• Language compliant with IEC 61131-3
standard
• PLC soft with real-time
• Communication Network Configuration
• Data Exchange with CANopen slave
modules
ORDER CODES
Code
Versions
UNICONTROL01
UNICONTROL02
Descriptions
Toolkit Isagraf, licence 64 tag
Toolkit Isagraf, licence 256 tag
ACCESSORIES
Z-POWER
S117P
Voltage transformer with output at 19 Vac
Asynchronous RS232-TTL/USB serial converter
• Primary Voltage 230 (115) Vac ± 10%
• Box in fiberglass self-estinguish (V-0)
• Protection by thermo-fuse
• Dimensions 3 DIN modules(15 VA), 5 DIN
modules (25 VA)
• IP 40
• Compliant with Windows (Xp, Vista, Xp Embedded, CE .Net), Mac OS (8, 9, X),
Linux (2.24.0 or next)
• Compliant with USB 1.0, 1.1, 2.0
• Isolation USB / RS232: 1.500 V
• Power Supply: loop powered from PC USB port
• RS232 connection: DB9
• TTL connection: RJ-10
• Dimensions: 90 x 50 x 25 mm
• Accessories: CD with driver
ORDER CODES
Code
Versioni
Z-POWER 230-15VA
Z-POWER 230-25VA
Z-POWER 115-15VA
ORDER CODES
Descriptions
Voltage Transformer 19 Vac, 230-15 VA
Voltage Transformer 19 Vac, 230-25 VA
Voltage Transformer 19 Vac, 115-15 VA
Code
S117P
Descriptions
Asynchronous RS232-TTL/USB serial converter
Z-PC DIN
DIN rail mounting bus support
• Installing on DIN rail guide 35 mm
• Hot swapping system for module insertion/removal
• 2, 4, 8 module slot configuration
RS485
24V
ORDER CODES
Code
STANDARD VERSION
Z-PC DINAL
Terminal block for power / bus
Z-PC DIN2
2 slot block
Z-PC DIN4
4 slot block
Z-PC DIN8
8 slot block
ORDER CODES
ORDER CODES
Code
SINGLE SMART BUS VERSIONS
Z-PC DINAL-A Terminal block for power / bus + 2 slot
Z-PC DIN2 -A
2 slot block
Z-PC DIN4 -A
4 slot block
Z-PC DIN8 -A
8 slot block
Code
DOUBLE SMART BUS VERSIONS
Z-PC DINAL-B Terminal block for power / bus + 1 slot
Z-PC DIN2 -B
2 slot block
Z-PC DIN4 -B
4 slot block
Z-PC DIN8 -B
8 slot block
CONNECTION CABLES
Codes
PM001420
PM001430
PM001440
PM001450
PM001460
PM001530
PM001601
PM001810
PM001820
PM001830
PM001840
PM001850
Description
RS232 serial cable (Z-TWS, Z-RTU, Z107, Z-LINK)
Modem communication cable (Z-TWS)
Modem and HMI communication cable
(ZTWS,Z-RTU)
Ethernet cable-right (Z-TWS – network device)
Crossing Ethernet cable (Z-TWS - PC)
Modem serial cable (Z-TWS, Z-RTU)
Programming serial cable (Z109REG, Z109REG2,
Z-4AI-D, Z-4TC-D, Z3AO, Z8AI, Z-8TC, Z-4RTD2, Z-SG, Z203)
Z-TOP / PC Programming cable
Z-TOP / Z-TWS-02 Communication cable
Z-TOP / Z-RTU Communication cable
Z-TOP / RS485 Communication cable
DB15F / DB15M Adapter ZTOP05, ZTOP11
Terminal Type
RJ10 / DB9F
RJ10 / DB25M
RJ10 / DB25M
RJ45 / RJ45
RJ45 / RJ45
RJ10 / DB9M
Jack / DB9F
DB15F / DB9F
DB15F / RJ10
DB15F / DB9M
DB15F / Bolt heads
DB15F / DB15M
Codes
PM001970
PM002240
PM002340
PM002350
PM002460
PM002470
PM002480
PM002490
PM002500
PM002510
PM002520
PM002530
Description
RS232 Serial Cable (K107B) Bolt heads / DB9F
Z109REG2 Programming cable / Test-3
Tp-Wire cable for Z-PROFIBUS
RS485 serial cable for Radiomodem
RS485 serial cable Tp-wire (Z-TWS)
Serial cable (Z-TWS, Z-RTU, Z107)
RS485 Serial cable (Z-TWS) RJ10 / Bolt heads
RS232 Serial cable – programming (
(ZRTU, M-RTU, radiomodem) DB9M / DB9F
RS232 modem for firmware updating
(ZRTU, M-RTU, radiomodem) DB9M / DB9F
Serial cable for radiomodem
Serial cable
Serial cable
Terminal Type
Jack / Jack
Tp-wire / Tp-wire
DB9M / Bolt heads
Tp-wire / Bolt heads
RJ10 / RJ10
DB9F / Puntali
DB9M / DB9M
DB9F / DB9F
27
2
CONVERTERS AND
INTERFACES
CONVERTERS AND INTERFACES
28
K-LINE
ACCURACY
CONNECTIONS
RELIABILITY
0,1%
• Spring clamp
• Expandable bus
connector on 35
mm guide (EN
60175)
> 500.000 h
OPERATING
TEMPERATURE
ISOLATION
POWER
CONSUMPTION
DIMENSIONS
APPROVALS
-20..+65°C
1,5 kVac
< 25 mA
6,2 mm
CE, UL
CSA
Z-LINE
POWER
TRANSDUCERS
Min
20 Vdc
ISOLATION
1,5..4 kVac
CONNECTION
SETTINGS
POWER SUPPLY
Screw fit
removable
terminals
• DIP-switch
• Software
• Hand-held
device
Vac/Vdc
switching
DIMENSIONS
APPROVALS
17,5 mm
CE, UL
CSA
UNIVERSAL
INPUTS
• Analog (mA, A,
mV, V, Ohm)
• Sensors (TC, RDT,
load cell)
• Pulse / Frequency
29
APPLICATION EXAMPLES
K107A
K107B
RS485 (Modbus) multiple serial lines connection
with galvanic isolation
RS232 / RS485 bidirectional remote transmission
with galvanic isolation up to 31 nodes
INDUSTRIAL I/O’S
AND TELECONTROL
max 32 nodes, 1200 m
max 32 nodes, 1200 m
Z109REG2
Multiple connection and data transmission with
USB/RS485 galvanic isolation
Isolation and analog conversion with multiplexing
function on re-transmitted output
Z109S
Z102
Isolation and re-transmission of 4..20 mA signal coming
from 2 wire sensor
Inverters serial control via potentiometer
4..20 mA
0..1000 Ohm
2 wire technique
power supply
SPEED
INDICATOR
PLC
analog
input
0..10 Vdc
Power
Supply
24 Vac/dc
4..20 mA
power supply
24 Vac/dc
INVERTER
4..20 mA
Z110
Z-SG
Measure signals isolation between transducers and
channel 1 - 4..20 mA
acquisition system
Load cell weight measure and analog re-transmission
of output signal
channel 2 - 4..20 mA
re-transmitted analog signal
PC (programming)
Power
Supply
(24 V)
Power
Supply
(24 V)
RS232
4..20 mA
4..20 mA
strain gauge
load cell
RS485 - ModBUS RTU
MEASUREMENT
DEVICES
sensor
INVERTER
DIGITAL
DISPLAYS
CONVERTERS
AND INTERFACES
K107USB
CONVERTERS AND INTERFACES
30
APPLICATION EXAMPLES
Z201
Z202
Alternate current conversion into mA/V normalized signal
Alternate voltage conversion into mA/V normalized signal
0/4..20 mA
0/4..20 mA
TA (es. 100 A / 5A)
Power supply
9..40Vdc / 19..28 Vac
Power supply
9..40Vdc / 19..28 Vac
0..500 Vac
Z203
Z-4AI-D
Single phase network analyzer with output signal
re-transmission
Analog signals acquisition and conversion into PLC
digital signals
PLC active / passive current inputs
or voltage inputs (0/2..10 Vdc)
passive sensor
power supply
10..40 Vdc / 19..28 Vac
+ 0/4..20 mA
Z104
Z111
Flow meter pulses counting with analog output
Real-time flow acquisition with pulse output
power supply
24 Vac/dc
+ 4..20 mA
proportional pulses
pulse counter
Flow meter with
analog output
pulsed output
counter
reed relay output (< 40 Hz)
or NPN (<10 kHz)
Z170
Z190
4..20 mA analog signal splitting
Average temperature control with 4.20 mA signals
4..20 mA
CHANNEL 2
4..20 mA
sensor
heater control
output
regulator
CHANNEL 1
4..20 mA
control
output
tank
CHANNEL 1
4..20 mA
CHANNEL 2
0..10 Vdc
output:
(channel 1 + channel 2)
4..20 mA
31
SIGNAL CONDITIONING BENEFITS
• TOTAL ISOLATION BETWEEN
SIGNAL AND POWER SUPPLY
CIRCUITS
Z-LINE
K-LINE
• SEPARATION OF SEVERAL
GROUNDS POTENTIAL
• RELIABILITY AND SECURITY
IN DATA TRANSMISSION
INDUSTRIAL I/O’S
AND TELECONTROL
CONTROL UNITS
• ISOLATION SUPPORTED
TRANSMISSION SECURITY
Flow
Pressure
• ELECTROMAGNETIC IMMUNITY
• PROTECTION AGAINST
HIGH GROUND POTENTIALS
Voltage
Current
Temperature
Speed
DIGITAL
DISPLAYS
Level
CONVERTERS
AND INTERFACES
• WIRING REDUCTION
Position
TYPICAL APPLICATION AREAS
METAL
INDUSTRY
OIL & GAS
FOOD &
BEVERAGE
PHARMACEUTICAL
SECTOR
BUILDING
CONSTRUCTIONS
HEAT ENGINEERING,
THERMOTECHNICS
NON-METAL
WORKINGS
ENERGY
WATER
INDUSTRY
MEASUREMENT
DEVICES
PAPER
INDUSTRY
32
CONVERTERS AND INTERFACES
K-LINE • ISOLATORS – TEMPERATURE CONVERTERS
K109PT
K109PT-HPC
K109PT1000
Pt100 to DC current
Pt100 to DC current / voltage
Pt1000 to DC current
/ voltage isolator converter isolator converter (high precision) / voltage isolator converter
K120RTD
K109TC
Pt100, Ni100 to DC current
converter (loop powered)
TC to DC current / voltage isolator
converter with settable threshold
ORDER CODES
Model
Accessories / Software
K109PT
K-BUS (Page 34)
K-SUPPLY (Page 34)
K109PT-HPC
K-BUS (Page 34)
K-SUPPLY (Page 34)
K109PT1000
K-BUS (Page 34)
K-SUPPLY (Page 34)
K120RTD
K-BUS (Page 34)
K-SUPPLY (Page 34)
KT120-TOOL (Page 34-41 )
K109TC
K-BUS (Page 34)
K-SUPPLY (Page 34)
19,2..30 Vdc
Yes
yes
21..25 mA (@ 24 Vdc)
500 mW
14 bit
Optical - digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
0,1% (max range)
< 100 ppm/K
Fault
Alarm
Programmable fault and cut-off
Insertable filter
19,2..30 Vdc
Yes
yes
21..25 mA (@ 24 Vdc)
500 mW
14 bit
Optical - digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
0,1% (max range)
< 100 ppm/K
Fault
Alarm
Programmable fault and cut-off
Insertable filter
19,2..30 Vdc
Yes
yes
21..25 mA (@ 24 Vdc)
500 mW
14 bit
Optical - digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
0,1%
< 100 ppm/K
Fault, alarm
DIP switch error
Programmable fault and cut-off
Insertable filter
19,2..30 Vdc
Yes
yes
21..25 mA (@ 24 Vdc)
500 mW
14 bit
Optical – digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 2 outputs
0,1%
< 100 ppm/K
CE, UL-UR CSA
EN 50081-2, EN 50082-2, EN
61010-1, EN 60742
CE
EN 50081-2, EN 50082-2, EN
61010-1, EN 60742
CE
EN 50081-2, EN 50082-2, EN
61010-1, EN 60742
Loop powered (5..30 Vdc)
21..25 mA (@ 24 Vdc)
500 mW
14 bit
Optical - digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
0,1%
< 100 ppm/K
Fault
Alarm
RTD type / connection, filter, measure range, error, output inversion,
over-range
CE
EN 50081-2, EN 50082-2, EN
61010-1, EN 60742
Pt100
IEC 751 standard / EN 60751 –
ITS90
Range: -150..+650 °C
Min span: 50 °C
Current on transmitter: 900 μA
Connection: 2,3,4 wire
Max cable resistance: 20 Ω
Pt100
IEC 751 standard / EN 60751 –
ITS90
Range: -200..+160 °C
Min span: 20 °C
Current on transmitter: 900 μA
Connection: 2,3,4 wire
Max cable resistance: 20 Ω
Pt1000
EN 60751/A2 – ITS90
Range: -200..+210 °C
Min span: 30 °C
Current on transmitter: < 350 μA
Connection: 2,3,4 wire
Max cable resistance: 50 Ω
Pt100 EN 60751/A2 – ITS90
Range: -200..+650 °C
Min span: 20 °C
Connection: 2,3,4 wire
Ni100
Range: -60..+250°C
Min span: 20 °C
Connection: 2,3,4 wire
Thermocouple
Type: J,K,E,N,S,R,B,T (ITS90)
Min span: 100 °C
Impedance: 10 MΩ
Semiconductor sold joint
ADC 13 bit, Precision: 0,15 °C
Update: 10 s
GENERAL DATA
Power supply
Power on side terminals
Hot swapping
Max current consumption
Max consumption
A/D conversion
Transmission
Rejection
Programming
Filter
Dimension (w x h x d)
Galvanic isolation
Isolation technique
Data processing
Color
Enclosure
Weight
Operating temperature
Connections
Protection degree
Channels
Accuracy
Thermal drif
LED
Embedded functions
Approvals
Norms
Programmable fault and cut-off
Insertable filter
CE, UL-UR CSA
EN 50081-2, EN 50082-2, EN
61010-1, EN 60742
INPUT DATA
Type
Tensione max ± 32V
Absolute value
OUTPUT DATA
Type
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0
mA
Max load resistance: 500 Ω
Protection: 25 mA
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0
mA
Max load resistance: 500 Ω
Protection: 25 mA
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0
mA
Max load resistance: 500 Ω
Protection: 25 mA
CURRENT
Range: 4..20 / 20..4 mA (2 wire)
Load resistance: 1 kΩ
Resolution: 0,5 μA (15 bit+sign)
Protection: 30 mA
Static relay
Response time (10-90%)
D/A conversion, resolution
< 50 ms (without filter)
< 200 ms (with filter)
1 mV, 2 μA
< 50 ms (without filter)
< 200 ms (with filter)
1 mV, 2 μA
< 50 ms (without filter)
< 200 ms (with filter)
1 mV, 2 μA
< 220 ms (without filter)
< 620 ms (with filter)
1 mV, 2 μA
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0
mA
Max load resistance: 500 Ω
Nominal voltage: 24 Vac/dc
Current: 60 mA
Overvoltage protection: 50 V
Settable hysteresys / alarm trip
< 40 ms (without filter)
< 88 ms (with filter)
1 mV, 2 μA
33
K-LINE • ISOLATORS – ANALOG CONVERTERS
DC low voltage to current /
voltage isolator converter
shunt converter
ORDER CODES
Model
Accessories / Software
K109UI
K-BUS (Page 34)
K-SUPPLY (Page 34)
K109S
K-BUS (Page 34)
K-SUPPLY (Page 34)
K109LV
K-BUS (Page 34)
K-SUPPLY (Page 34)
19,2..30 Vdc
Yes
Yes
22 mA (@ 24 Vdc)
500 mW
14 bit
Optical - digital
50 – 60 Hz (settable)
DIP switch, I2C
Insertable
93,1 x 6,2 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
0,1% (max range)
< 100 ppm/K
Fault, alarm
Square root extraction
Signal inversion
Programmable scales
Programmable cut-off
Standard tanks linearization
CE, UL-UR CSA
EN 61010-1, EN 60742, EN 61000-2, EN 61000-4
19,2.. 30 Vdc
Yes
Yes
23 mA (24 Vdc); 45 mA (aux supply)
500 mW
14 bit
Optical – digital
50 - 60 Hz (settable)
DIP Switch, I2C
Insertable
93,1 x 6,2 x 102,5 mm
1,5 kVac @ 3 way (50 Hz, 1 min)
Digital (optocoupler)
Calcolo floating point 32 bit
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP 20
1 input, 1 output
0,1%
< 120 ppm/K
Fault, alarm
Square root extraction
Signal inversion
Programmable cut-off
Standard tanks linearization
Auxiliary power supply 17..20 V, max current 25 mA
CE, UL-UR CSA
EN 61010-1, EN 60742, EN 61000-2, EN 61000-4
19,2.. 30 Vdc
Yes
Yes
22 mA (24 Vdc)
500 mW
14 bit
Optical – digital
50 - 60 Hz (settable)
DIP Switch, I2C
Insertable
93,1 x 6,2 x 102,5 mm
1,5 KV @ 3 way (50 Hz, 1 min)
Digital (optocoupler)
Calcolo floating point 32 bit
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP 20
1 input, 1 output
0,1%
< 120 ppm/K
Fault, alarm
Programmable fault and cut-off
Insertable filter
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 / 0..15 / 0..30 V (reversed)
Impedance: 110 kΩ - 325 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0 mA
Impedance: 35 Ω
±32 V (current clamp self powered: 400 mΩ)
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Impedance: 110 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0 mA
Impedance: 35 Ω
±30 V (current clamp self powered: 400 mΩ)
SHUNT SIGNAL
Range: ±25, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300,
400, 500, 1000, 2000 mV (programmable via DIP switch)
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0 mA
Max load resistance: 500 Ω
Protection: 25 mA
< 40 ms (without filter)
< 88 ms (with filter)
1 mV, 2 μA
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0 mA
Max load resistance: 500 Ω
Protection: 25 mA
< 40 ms (without filter)
< 88 ms (with filter)
1 mV, 2 μA
VOLTAGE
Range: 0..10 / 10..0 / 0..5 / 1..5 V
Min load resistance: 2 kΩ
CURRENT
Range: 4..20 / 20..4 / 0..20 / 20..0 mA
Max load resistance: 500 Ω
Protection: 25 mA
< 25 ms (without filter)
< 55 ms (with filter)
GENERAL DATA
Power supply
Power on side terminals
Hot swapping
Max current consumption
Max consumption
A/D conversion
Transmission
Rejection
Programming
Filter
Dimension (w x h x d)
Galvanic isolation
Isolation technique
Data processing
Color
Enclosure
Weight
Operating temperature
Connections
Protection degree
Channels
Accuracy
Thermal drif
LED
Embedded functions
Approvals
Norms
CE
EN 61010-1, EN 60742, EN 61000-2, EN 61000-4
INPUT DATA
Type
Absolute value
INDUSTRIAL I/O’S
AND TELECONTROL
DC current / voltage to current /
voltage isolator converter
(2 wire power transducers)
K109LV
CONVERTERS
AND INTERFACES
DC current / voltage to current /
voltage isolator converter
K109S
DIGITAL
DISPLAYS
K109UI
± 50 V
Response time (10-90%)
D/A conversion, resolution
MEASUREMENT
DEVICES
OUTPUT DATA
Type
CONVERTERS AND INTERFACES
34
K-LINE • ISOLATORS – SERIAL CONVERTERS AND ACCESSORIES
K107A
K107B
K107USB
K-SUPPLY
RS485 / RS485 serial
isolator/repeater
RS232/RS485 serial
isolator/converter
RS485/USB asynchronous
serial converter
Redundant power supply
module
ORDER CODES
Model
K107A
K107B
K107USB
Accessories / Software
K-BUS (Page 34)
K-SUPPLY (Page 34)
K-BUS (Page 34)
K-SUPPLY (Page 34)
K-BUS (Page 34)
K-SUPPLY (Page 34)
19,2.. 30 Vdc
Yes
Yes
22 mA (24 Vdc)
500 mW
50 – 60 Hz (programamble)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
Power ON
Data ok
Inverted connection
Automatic handshake
Baud rate: 1.200..115.200 bps
19,2.. 30 Vdc
Yes
Yes
22 mA (24 Vdc)
500 mW
50 – 60 Hz (programamble)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac @ 3-way (50 Hz, 1 min)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
Power ON
Data ok
Inverted connection
Automatic handshake
Baud rate: 1.200..115.200 bps
Via USB port
Yes
60 mA
19,2.. 30 Vdc
Yes
Yes
50 – 60 Hz (programamble)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac (USB ( RS485)
Digital (optocoupler)
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
1 input, 1 output
Power ON
Data ok
Inverted connection
50 – 60 Hz (programamble)
DIP switch, I2C
Insertable
6,2 x 93,1 x 102,5 mm
1,5 kVac
32 bit floating point
Black
PBT
45 g
-20..+65 °C
Clamp terminals / bus
IP20
2 inputs, 1 output
Input switch on threshold
Alternate input polarity
Compliance to USB 1.1 and 2.0
Plug&play for WIN 98, 2000 and XP
Differential mode filter
Overvoltages protection
Power supply redundant connection
CE
EN 50081-2, EN 50082-2, EN 61010-1, EN
60742, EN 61000-6-4, EN 61000-6-2
K-SUPPLY
GENERAL DATA
Power supply
Power on side terminals
Hot swapping
Max current consumption
Max consumption
Rejection
Programming
Filter
Dimension (w x h x d)
Galvanic isolation
Isolation technique
Data processing
Color
Enclosure
Weight
Operating temperature
Connections
Protection degree
Channels
LED
Communication
Embedded functions
Approvals
Norms
CE, UL-UR CSA
EN 61010-1, EN 60742, EN 61000-2, EN
61000-4
CE, UL-UR CSA
EN 61010-1, EN 60742, EN 61000-2, EN
61000-4
CE
EN 61010-1, EN 60742, EN 61000-2, EN
61000-4
SERIAL
Half duplex, 31 nodes, terminal, protection
up to 30 Vdc
SERIAL
RS232B, protection up to 30 Vdc
SERIAL
POWER SUPPLY
USB interface, standard USB 1.0/ 2.0 com- 2 inputs with shared negative terminal
pliance, USB A and MINI USB B connection Pass-through each input can be accessed
by 2 pairs of terminals
Max current per terminal: 4 A
Positive inputs protected by an external
fuse of recommended sizing
SIDE A
Type
SIDE B
Type
SERIAL
SERIAL
SERIAL
RS485 half duplex, 31 nodes, terminal, pro- RS485 half duplex, 31 nodes, terminal, pro- RS485, max 31 nodes, spring cage termitection up to 30 Vdc
tection up to 30 Vdc
nal block
K-BUS
POWER SUPPLY
Max voltage drop: 300 mV
KT120-TOOL
Expandable power supply connector (EN 60175)
T120 and K120RTD configuration toolkit
Each expandable connector K-BUS allows inserting two modules. KBUS are inserted on guide setting them to the top and round them at the bottom.
POWER SUPPLY TECHNIQUE
K Line signal conditioners can be powered in 3 different ways: by the spring cage
terminal block (24 Vdc direct from power supply) or by SMART SUPPLY system.
SMART SUPPLY system is based on expandable KBUS connector.
T120 and K120RTD configuration toolkit including S117P (USB – RS232/TTL converter), PM002411 (S117P connecting cable), KT120 (programming software)
ORDER CODES
Code
K-BUS
Description
2 slot expandable power supply connector
ORDER CODES
Code
Description
KT120-TOOL
T120 and K120RTD configuration toolkit
35
Z109REG
Z109REG2•Z109REG2-H
Z109UI2
Z109S
Universal
isolator/converter
Universal isolator/converter
with advanced functions
DC Current/Voltage to DC
Current/Voltage isolator/converter
DC Current isolator
ORDER CODES
Models
Z109REG
-ER (square root extraction)
Programming & Accessories
Page 41
Z109REG2 (9..40 Vdc/19..28 Vac)
Z109REG2-H (85..265 Vac/dc)
-ER (square root extraction)
Page 41
Z109UI2
Z109S
Page 41
Page 41
Z109REG2: 9..40 Vdc;
19..28 Vac; (50..60 Hz)
Z109REG2-H: 85..265 Vac/dc
20 Vdc, not regulated
2,5 W (max)
1,6 W (24 Vdc, 20 mA)
1.500 Vac;
3.750 Vac (power supply / input -output)
Against pulse overvoltages 400W/ms
Power supply
Error
Alarm
35 ms (11 bit)..140 ms (16 bit)
0,1%
0,01%/°K
0,05% / 0.4%
DIP switch
Z-SETUP2 (PC software)
Test-3 (hand held calibrator)
-10..+60°C
17,5 x 100 x 112 mm
Screw-fit removable terminals for wires up to 2.5 mm2
200 g
CE, UL-UR CSA
EN 61000-6-4 / 2002, EN 61000-2-2/2005 /
EN 61010-1, EN 60742
10..40 Vdc
19..28 Vac; (50..60 Hz)
9..40 Vdc
19..28 Vac; (50..60 Hz)
20 Vdc, not regulated
2,5 W
20 Vdc, not regulated
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
Power supply
Power supply
35 ms (11 bit)..140 ms (16 bit)
0,1%
0,01%/°K
0,05 % (V,I), 0,01% (Vout)
DIP switch
Jumper
< 60 ms
0,2 %
0,02 % f.s. / °C
0,05 %
-10..+60°C
17,5 x 100 x 112 mm
Screw-fit removable terminals for wires up to 2.5 mm2
200 g
CE
EN 55011, EN 61000-4-2, EN 61000-4-4,
EN 50140 / 141
0..+50°C
17,5 x 100 x 112 mm
Screw-fit removable terminals for wires up to 2.5 mm2
200 g
CE
EN 55011, EN 61000-4-2, EN 61000-4-4,
EN 50140 / 141
1
VOLTAGE (mV, V)
Bipolar 0..2, 0..5, 0..10 V
• CURRENT (mA)
Bipolar 0..20 mA
• RTD Pt100 (-200..+600°C)
• THERMOCOUPLE
Tipo J, K, R, S, T, E, B, N
• POTENTIOMETER
0,5..15 kΩ
1 analog, 1 strobe
• VOLTAGE (mV, V)
Bipolar da 75 mV a 20 V
Resolution 15 bit + sign
• CURRENT (mA)
Bipolar up to 20 mA
Resolution 1 μA
• RTD
Pt100, Pt500, Pt1000, Ni100,
KTY81,KTY84, NTC
Measure 3, 4 wires
Range: -200..600 °C
Resolution 0,1°C
• THERMOCOUPLE
Type J, K, R, S, T, E, B, N
Resolution 2,5 μV
• POTENTIOMETER: 500 Ω ..10 kΩ
• RHEOSTAT: 500 Ω..25 kΩ
• STROBE: alternative to the relay output
1
• VOLTAGE (mV, V)
Bipolar da 75 mV a 20 V
Resolution 15 bit + sign
• CURRENT (mA)
Bipolar up to 20 mA
Resolution 1 μA
1
CURRENT (mA)
2 scales: 0/4..20 mA
Max resistance load: 600 Ω
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
CURRENT (mA)
2 scales: 0/4..20 mA
1 analog, 1 relay
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.000 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
• RELAY
Alternative to the strobe NC / NA in case of
alarm
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.000 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
1
CURRENT (mA)
2 scales: 0/4..20 mA
Max resistance load: 600 Ω
INDUSTRIAL I/O’S
AND TELECONTROL
Z-LINE • ISOLATORS – ANALOG CONVERTERS
9..30 (option) - 19..40 Vdc
19..28 Vac; (50..60 Hz)
Power transducers
Max Consumption
18 Vdc, not regulated
2,5 W (max)
Galvanic Isolation & Protection
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
Status indicators
Power supply
Error
Response time
Accuracy class
Thermal stability
Linearity
Setting
300 ms
0,2%
0,02 % f.s. / °C
0,05% (V,I), 0,2% (RTD),1°C (TC)
DIP switch
Z-SETUP (PC software)
Operating Temperature
Dimension (w x h x d)
Electrical Connections
Weight
Approvals
Norms
0..+55°C
17,5 x 100 x 112 mm
Screw-fit removable terminals for wires up to 2.5 mm2
200 g
CE
EN 50081-1, EN 50082-2, EN 61010-1
CONVERTERS
AND INTERFACES
GENERAL DATA
Power Supply
MEASUREMENT
DEVICES
OUTPUT DATA
Nr
Type
DIGITAL
DISPLAYS
INPUT DATA
Nr
Type
CONVERTERS AND INTERFACES
36
Z-LINE • ISOLATORS – ANALOG CONVERTERS & A/D CONVERTERS FOR PLC
Z102
Z110
Z-4AI-D
Z-4TC-D
Z-SG
Potentiometer to DC
Current/Voltage
isolator/converter
DC Current isolator (self
powered by the input)
single & double channel
4 Analogue Signals
A/D Converter
4 Thermocouple
A/D Converter
Strain gauge to DC
Current/Voltage
isolator/converter
ORDER CODES
Z-4AI-D
Z-4TC-D
Z-SG
Page 41
Page 41
Page 41
Self powered by the input current
9..30 (opt.) - 19..40 Vdc
19..28 Vac (50..60 Hz)
9..30 (opt.) - 19..40 Vdc
19..28 Vac (50..60 Hz)
1.500 Vac, 2 way
1.500 Vac, 3 way
1.500 Vac, 3 way
10..40 Vdc
19..28 Vac
2W
1.500 Vac, 3 way
Power supply
Error
Data Transmission
Data reception
< 400 ms
Power supply
Error
Data Transmission
Data reception
< 400 ms
IEC 61131 PLC libraries
DIP switch (filter time,input time,
scale, serial interface)
Z-PROG (PC software)
PLC IEC 61131 libraries
DIP switch (filter time,input time,
scale, serial interface)
Z-PROG (PC software)
0..+50°C
17,5 x 100 x 112 mm
Screw-fit removable terminals
200 g
CE, UL-UR CSA
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
0..+50°C
17,5 x 100 x 112 mm
Screw-fit removable terminals
200 g
CE, UL-UR CSA
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
-10..+65°C
17,5 x 100 x 112 mm
Screw-fit removable terminals
200 g
CE
EN 61000-6-4, EN 61000-6-2, EN
61010-1, EN 60742, IEC 61131
1
1,2
RHEOSTAT
• CURRENT (mA)
2 wires: 0..300 Ω (I=6mA); 0..500 4..20 mA
Ω
(I=3,6 mA); 0..1 K Ω (I=1,8 mA)
• POTENTIOMETER
3 wires: Vref=1,8 Vcc, da 200 Ω a
1M Ω
4
VOLTAGE (V)
2..10 V f.s (bipolar)
Resolution: 16.000 points
Impedance: 100 K Ω
• CURRENT (mA)
± 20 mA (bipolar)
Resolution: 16.000 points
Impedance: 100 Ω
4
VOLTAGE
± 80 mV f.s (bipolar)
Impedance 10 M Ω
• THERMOCOUPLE
Type J, K, R, S, T, E; B, N
1 analog, 1 digital
ANALOG
Load Cell (Strain Gauge), 4 or 6
wires connections, min 87 Ω for
1..4 load cells(350 Ω) or 1..8
Load cells (1.000 Ω);
Sensibility: 1..64 mV/V
• DIGITAL
Tare calibration
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
2
DIGITAL
Channel from/to control unit (1 settable as clock or reset input)
2
DIGITAL
Channel from/to control unit (1 settable as clock or reset input)
1analog, 1 digital
• CURRENT (mA)
0..20, 4..20 mA
• VOLTAGE (V)
0..10, 0..5 Vdc
• DIGITAL
weight limit
Models
Z102
Programming & Accessories
Page 41
Z110S (single channel)
Z110D (double canne)
Page 41
GENERAL DATA
Power Supply
Max consumption
Galvanic Isolation & Protection
Status indicators
9..30 (option) - 19..40 Vdc
19..28 Vac (50..60 Hz)
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
Power supply
Response time
Communication Interface
40 ms
100 ms
Accuracy class
Thermal stability
Linearity
Setting
0,2%
0,02 % f.s. / °C
0,05 %
Dip-switch (zero and span)
0,1%
0,02 % f. / °C
0,1 % f.s
Operating Temperature
Dimension (w x h x d)
Electrical Connections
Weight
Approvals
Norms
0..+50°C
17,5 x 100 x 112 mm
Screw-fit removable terminals
200 g
CE
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
0..+50°C
17,5 x 100 x 112 mm
Screw-fit removable terminals
200 g
CE
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
Power supply
Error
Data Transmission
Data reception
< 10 ms
2 wire RS485
RS232, front jack, speed 2400
Baud, data bits 8, Parity: NO, Stop
bits:1
0,01%
0,0025% / °C
0,01%
Dip-switch
Software (Z-NET)
INPUT DATA
Nr
Type
OUTPUT DATA
Nr
Type
1,2
• CURRENT (mA)
4..20 mA
37
T201
AC Current to DC Current
isolator/converter
(loop powered)
Z201 • Z201-H Z202 • Z202-H• Z202-LP
AC current to DC
Current/Voltage
isolator/converter
AC Voltage to DC
Current/Voltage
isolator/converter
Z203
S203T • S203TA
Single Phase
Network Analyzer
Advanced Three
Phase Network
Analyzer
ORDER CODES
Models
T201
Z201 (19..40 Vdc / 19..28 Vac)
Z201-H (85..265 Vac/dc)
Z202 (10..40 Vdc / 19..28 Vac)
Z203 (10..40 Vdc / 19..28 Vac)
Z202-H (85..265 Vac/dc)
Z202-LP (5..28 Vdc loop powered)
Page 41
Page 41
S203T (input up to 100 mA)
S203TA (input up to 5 Arms)
Programming & Accessories
Page 41
Page 41
Power Supply
Loop powered (5..28 Vdc)
19..40 Vdc / 19..28 Vac (Z201)
85..265 Vac/dc (Z201-H)
10..40 Vdc
19..28 Vac (50..60 Hz)
10..40 Vdc
19..28 Vac (50..60 Hz)
2,5 W
3.750 Vac (output / power supply)
1.500 Vac (other circuits)
4.000 Vac (Z201-H)
19..40 Vdc / 19..28 Vac (Z202)
85..265 Vac/dc (Z202-H)
5..28 Vdc (Z202-LP)
< 1,5 W
3.750 Vac (from / to input)
1.500 Vac (other circuits)
4.000 Vac (Z202-H, Z202-LP)
Max consumption
Galvanic Isolation & Protection
CAT III 300 Vac
2,5 W
3.750 Vac (from / to input)
1.500 Vac (other circuits)
< 2,5 W
3.750 Vac (from / to input)
1.500 Vac (other circuits)
4 kV (ESD)
Power supply
Power supply
< 200 ms (Z201)
100 ms (Z201-H)
30 ms (Z202)
< 100 ms (Z02-H, Z202-LP)
TA15 (S203T f.s. 15 A, 0,1%)
TA25 (S203T f.s. 25 A, 0,1%)
TA100 (S203T f.s. 100 A, 0,1%)
INDUSTRIAL I/O’S
AND TELECONTROL
Z-LINE • ISOLATORS – ELECTRIC PARAMETERS CONVERTERS
Response time
< 100 ms
Communication Interface
Accuracy class
Thermal stability
Linearity
Setting
0,2%
115 ppm/°K
0,3 %
0,02 % f.s. / °C
0,1 %
DIP switch
0,25 %
100..150 ppm/K
0,05 %
Dip-switch, jumper, trimmer
Operating Temperature
-20..+65 °C
0..+55 °C (Z201)
-10..+ 65 °C (Z201-H)
Electrical Connections
Faston (6,3 x 0,8 mm)
Screw-fit removable terminals for
wires up to 2.5 mm2
0..+60°C (Z202)
-10..+ 65 °C (Z202-H)
-120..+ 65 °C (Z202-LP)
Screw-fit removable terminals for
wires up to 2.5 mm2
Dimension (w x h x d)
Weight
Approvals
Norms
38 x 40 x 20 mm
50 g
CE
EN 60668+A1+A2, EN 61000-6-4,
EN 61000-6-2, EN 61010-1
17,5 x 100 x 112 mm
200 g
CE
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
1
CURRENT alternate (A)
5, 10, 15, 20, 25, 30, 35, 40 A
Max overcurrent : 800 A
Frequency: 20..1.000 Hz
Crest factor: 2
1
CURRENT (mA)
4..20 mA (2 wires)
DIP switch
Power supply
Error
Data Transmission
Data reception
< 10 ms
400 ms
RS485, 2 wires, 1.200..115k bps
RS232, 2.400 bps ModBUS RTU
protocol
0,5%
RS485, 2 fili, 1.200..115k bps
ModBUS RTU Slave protocol
DIP switch
Software (Z-NET)
-10..+65 °C
DIP switch
Software (Z-NET)
-10..+65 °C
0,2%
Screw-fit removable terminals for
wires up to 2.5 mm2
IDC10Back connecto for DIN rail
Jack frontale RS232 (ModBUS)
17,5 x 100 x 112 mm
17,5 x 100 x 112 mm
140 g
140 g
CE
CE, UL-UR CSA
EN 60688+A1+A2, EN50081-2,
EN 61000-6-4/2002, EN 61000-6EN50082-2, EN61010-1, EN60742 2/2002, EN 61010-1
Screw-fit removable terminals for
wires up to 5,08 mm2
1
CURRENT alternate (A)
0..5, 0..10 A
1
VOLTAGE alternate (V)
Range 0..500 Vac, 41 scales
Input impedance 2.000 Ω/V
Frequency 10 Hz..1kHz
1 (6 measure)
• VOLTAGE alternate (V)
0..500 Vac max (50-60 Hz)
• CURRENT alternate (A)
0..5 A (rms)
1
VOLTAGE alternate (V)
Up to 600 Vac
• CURRENT alternate (A)
S203T: nominal 15 (25,
100) mA(rms)
S203TA: 5A
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA
(active/passive)
Max load resistance: 600 Ω
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA
(active/passive)
Max load resistance: 600 Ω
4..20 mA (Z202-LP)
1 (6 measure)
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA
Analog retransmission of: Vrms,
Irms, P, Q, cosФ
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA
(active/passive)
Max load resistance: 600 Ω
Error : 0,1%
Measured values: Vrms, Irms, P,
Q, S, f, cosФ, Energy
105 x 89 x 60 mm
200 g
CE
EN 61000-6-4/2002, EN 61000-62/2002, EN 61010-1, EN 60742
DIGITAL
DISPLAYS
Status indicators
CONVERTERS
AND INTERFACES
GENERAL FEATURES
OUTPUT DATA
Nr
Type
MEASUREMENT
DEVICES
INPUT DATA
Nr
Type
CONVERTERS AND INTERFACES
38
Z-LINE • ISOLATORS – TEMPERATURE CONVERTER
Z109PT2
Z109TC
T120
FlexTop
FlexTop ISO
RTD to DC
Current/Voltage
isolator/converter
TC to DC
Current/Voltage
isolator/converter
PT100 and NI100 to
DC current converter
(loop powered)
PT100 to DC
current converter
(loop powered)
Universal Input to DC
current converter
(loop powered)
ORDER CODES
Models
Z109PT2
Z109TC
T120
T120SETUP
(programming kit)
Page 41
FLEXTOP (standard)
-C (configured version)
-EX (EEXia version)
Page 41
FLEXTOP ISO (standard)
-C (configured version)
-EX (EEXia version)
Page 41
Programming & Accessories
Page 41
Page 41
9..40 Vdc,
19..28 Vac (50..60 Hz)
2,5 W
1.500 Vac, 3 way
Input: 100mA
Against pulse overvoltages
400W/ms
9..30 (opt.) - 19..40 Vdc
19..28 Vac (50..60 Hz)
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages
400W/ms
5..30 Vdc (loop powered)
8..35 Vdc (loop powered)
6,5..35 Vdc (loop powered)
Enclosure IP40, IP00 connectors
Enclosure IP40, IP00 connectors
3,75 KVac, 2 way
Power Supply
Setting Error
Out of scale
35..140 ms
Power Supply
Error
Thermal stability
0,1% (RTD)
0,3% (Voltage output)
0,02 % f.s. / °C
Linearity
0,1 %
Setting
Dip-switch: input type, output
(range and type), full scale
0,2% - input
0,1% - output
±0,02% f.s./°C- input
±0,01% f.s./°C- output
1°C, 3°C over 600°C
0,1% output
Dip-switch: start and full scale,
output, TC type)
TC emulator
Operating Temperature
Electrical Connections
Dimension (w x h x d)
Weight
Approvals
-10..+60°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE
0..+50°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE
Norms
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
EN 55011, EN 61000-4-2, EN
61000-4-4, EN 50140 / 141
EN 61000-6-4, EN 61000-6-2
1
• RTD
Pt100, Pt500, Pt1000,
Ni100,KTY81, KTY84, NTC
Wiring at 2, 3, 4 wires
Excitation current 1 mA
Resolution 0,1°C
1
• THERMOCOUPLE
Type: J, K, R, S, T, E, B, N
Resolution 5 μV
Automatic detection of interruption
1
• Pt100 Standard: EN 60751/A2
(ITS-90)
Measure range: -200..+650°C
Span min.: 20°C
Wiring at 2,3,4 wires
• Ni100
Measure range: -60..+650°C
Span min.: 20°C
Wiring at 2,3,4 wires
1
• Pt100
Wiring at 2, 3, 4 wires
Standard IEC/DIN/EN 60 751-2
Measure range: -200..+850 °C
Span min. 25 °C
Protection ± 35 Vdc
1
• RTD
Pt25..Pt1000, Ni25..Ni1000,
Cu25..Cu1000
Wiring at 2,3,4 wires
• THERMOCOUPLE
B,E,J,K,L,T,U,IEC 584, ASTM 988
• VOLTAGE (mV, V)
Range: -10..70 mV, -0,1..1,1 V
• Ohm
Range: 0..390 Ω, 0..2.200 Ω
Protection ± 35 Vdc
1
• VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.000 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
1
•VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
1
• CURRENT (mA)
4..20, 20..4 mA (2 wires)
Resolution: 1μA, max 16 bit
Load resistance: 1 kΩ @ 26
Vdc, 21 mA
Protection: 30 mA
1
• CURRENT (mA)
4..20 (2 wires)
Resolution: 12 bit
1
• CURRENT (mA)
4..20, 20..4 (2 wires)
Resolution: 12 bit
GENERAL FEATURES
Power Supply
Max consumption
Galvanic Isolation & Protection
Status indicators
Response time
Accuracy class
Sensor interrupted
330 ms
<220 ms (<620ms with rejection
50-60 Hz)
0,1%
0,7 s
< 100 ppm (30 ppm usual)
Max ±0,01% f.s./°C -±0,003%
f.s./°C usual
0,1 %
KT120-TOOL ( programming kit:
start / full scale,
RTD type and elec. connection,
rejection, filter, cable resistance,
output interrupted/over-range)
-40..+85°C
Spring loaded system
Ø 43,7 x 20 mm
Flex Programmer (sw toolkit)
Damping programmable
Technical unit selection
Tag settable up to 15 carachters
CE
CE, EEx ia IIC T5/T6 ATEX II 1G CE, Namur NE 21,
(Versioni EEx)
Demko EEx ia IIC T5/T6
EN50081-1, EN50081-2 EN50014, EN 61326
EN50020
0,1%
-40..+85 °C
Spring loaded system
Ø 44 x 19 mm
0,1%
Max ±0,01% f.s./°C -±0,003%
f.s./°C usual
Flex Programmer (sw toolkit)
Damping programmable
-40..+85 °C
Spring loaded system
Ø 44 x 26,3 mm
INPUT FEATURES
Nr
Type
OUTPUT FEATURES
Nr
Type
Flex Programmer
• Data storage function
• Saving and uploading of setting values
• Printing of calibration report
ORDER CODES
SOFT-FLEX
SOFT-FLEX Flextop and Flextop ISO programming KIT
• Interface converter with cable lenght of 1,5 mt and RS232C
9-pole connector for PC
• Multilanguage software on CD
39
Z111
Z170
Z190
DC Current/Voltage to
frequency isolator/converter
Frequency to DC Current/Voltage
isolator/converter
DC Current/Voltage
duplicator/isolator
DC Current/Voltage
adder/subtractor
ORDER CODES
Models
Programming & Accessories
Z104
Page 41
Z111
Page 41
Z170
Page 41
Z190
Page 41
19..40 (9..30 opt.) Vdc;
19..28 Vac (50..60 Hz)
Yes, min 20 Vdc
2,5 W
1.500 Vac, 3 way
Input: 100mA
Against pulse overvoltages 400W/ms
Power Supply
Output (Relay attracted)
350 ms
0,2 %
0,02 % f.s. / °C
0,05 %
Dip-switch: input type, output, end scale
Trimmer: end scale setting, integration constant
19..40 (9..30 opt.) Vdc;
19..28 Vac (50..60 Hz)
Yes, min 20 Vdc
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
19..40 Vdc;
19..28 Vac (50..60 Hz)
Yes, min 20 Vdc
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms
19..40 (9..30 opt.) Vdc;
19..28 Vac (50..60 Hz)
Yes, min 20 Vdc
2,5 W
1.500 Vac, 3 way
Against pulse overvoltages 400W/ms.
Power Supply
Error
250 ms
0,3%
0,01 % f.s. / °C
Power Supply
Power Supply
0,2 %
0,02 % f.s. / °C
0,05 %
DIP switch
I/O type and electrical connections
0,2 %
0,02 % f.s. / °C
0,05 %
DIP switch
I/O type and electrical connections
0..+50°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE
EN50081-1, EN50081-2, EN61010-1
0..+50°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE, UL-UR CSA
EN50081-1, EN50081-2, EN61010-1
0..+50°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE, UL-UR CSA
EN50081-1, EN50081-2, EN61010-1
0..+50°C
Screw-fit removable terminals
17,5 x 100 x 112 mm
200 g
CE
EN50081-1, EN50081-2, EN61010-1
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Input impedance 1 MΩ
• CURRENT (mA)
2 scales: 0/4..20 mA
Active Input: 15 Vdc (not regulated)
Passive Input: impedance 100 Ω
1
PULSE
Contact / reed; npn 2/3 wires; pnp 3 wires
with
24 Vdc power; namur; photoelectric; hall
effect sensor, variable reluctance, 24V; TTL
Max frequency: 10 kHz
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Input impedance 500 KΩ
CURRENT (mA)
2 scales: 0/4..20 mA
Active Input: 20 Vdc (not regulated)
Passive Input: impedance 100 Ω
2
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Input impedance 500 KΩ
CURRENT (mA)
2 scales: 0/4..20 mA
Active Input: 20 Vdc (not regulated)
Passive Input: impedance 100 Ω
1
PULSE
Transistor npn open collector, 30 Vcc, 300
mA, reed relè, 30 Vdc-ac, 100 mA
Max frequency: 10 kHz
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Min load resistance: 2.500 Ω
CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
2
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Input impedance 2.500 Ω
• CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
1
VOLTAGE (V)
4 scales: 0..1, 0..5, 0..10, 2..10 V
Input impedance 2.500 Ω
CURRENT (mA)
2 scales: 0/4..20 mA (active/passive)
Max load resistance: 600 Ω
GENERAL DATA
Power Supply
Power transducers
Max consumption
Galvanic Isolation
Protections Input/Power Supply
Status indicators
Response time
Accuracy class
Thermal stability
Linearity
Setting
Operating Temperature
Electrical Connections
Dimension (w x h x d)
Weight
Certification
Norms
Dip-switch: input type, filter, pulses average, output
Trimmer: end scale setting (1 Hz..10KHz)
CONVERTERS
AND INTERFACES
Z104
INDUSTRIAL I/O’S
AND TELECONTROL
Z-LINE • ISOLATORS – PULSE CONVERTERS AND SIGNAL PROCESSORS
MEASUREMENT
DEVICES
OUTPUT DATA
Nr
Type
DIGITAL
DISPLAYS
INPUT DATA
Nr
Type
CONVERTERS AND INTERFACES
40
Z-LINE • ISOLATORS – RELAY CONDITIONERS
Z112A •Z112D
ON / OFF Sensors amplifier
Z113S • Z113D • Z113T
* Z-TIMER • Z-TIMER-D
DC Current / Voltage alarm
trip module
Electronic timer
ORDER CODES
Z-TIMER
Z-TIMER-D (with 2 independent times)
Page 41
Z113S (1 relay output)
Z113D (2 relay outputs)
Z113T (3 relay outputs)
Page 41
Power Supply
19..40 (9..30 opt.) Vdc;
19..28 Vac; (50..60 Hz)
19..40 (9..30 opt.) Vdc
19..28 Vac; (50..60 Hz)
12..40 Vdc ± 10 %
12..40 Vac / 115..230 Vac ± 10 % 50..60 Hz
Power transducers
Max consumption
Galvanic Isolation
Yes, active input 2 wire (min 20 Vdc)
2,5 W
Z112A: 1.500 Vac (power supply/input)
4.000 Vac (input/power supply/output)
Z112D:1.500 Vac
Yes, active input 2 wire (min 20 Vdc)
2,5 W
1.500 Vac, 3 way
Yes, active input 2 wire (min 20 Vdc)
2W
1.500 Vac (power supply/input)
4.000 Vac (input/power supply/output)
Models
Z112A (single channel)
Z112D (double channel)
Programming & Accessories
Page 41
GENERAL FEATURES
Protections Input/Power Supply
Status indicators
Power Supply
Relay attracted
Against pulse overvoltages 400W/ms.
Power Supply
Overtaking limit
Thermal stability
Linearity
Setting
±0,01% /°C
Operating Temperature
Electrical Connections
Dimension (w x h x d)
Weight
Certification
Norms
0..+50°C
Screw-fit removable terminals for wires up to 2.5 mm2
17,5 x 100 x 112 mm
200 g
CE
EN 50081-1, EN 50082-2, EN 61010-1
0..+50°C
Screw-fit removable terminals for wires up to 2.5 mm2
17,5 x 100 x 112 mm
200 g
CE
EN 50081-1, EN 50082-2, EN 61010-1
-10..+60°C
Screw-fit removable terminals for wires up to 2.5 mm2
17,5 x 100 x 112 mm
200 g
CE
EN 50081-1, EN 50082-2, EN 61010-1
1/2
PULSE
Contact optoisolated
Reed
npn 2/3 wires- 12..24 Vdc
pnp 3 wires, power supply 24 Vdc
NAMUR
Pulses 24 Vdc
Photoelectric sensor
Hall effect sensor
Max frequency 400 Hz
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc
Impendance: Current 100 Ω, Voltage: 500 KΩ
1
CONTACTS
START Timer
PAUSA Timer
SELECTION (Z-TIMER-D)
1/2
RELAYS
Z112A: relay SPDT 1 A - 30 Vdc o 5 A – 250 Vac (resistive
load)
Z112D: reed relay SPST, max load0,5 A – 100 Vdc-ac (10
VA resistive load)
1/2/3
Z-113A: relay SPDT, 1A – 30 Vdc load or 5 A – 250 Vac
(resistive load)
Z-113D/T: relay SPST, max load 0,1 A – 30 Vdc-ac (10VA
resistive load)
1
RELAY
SPDT 8 A – 250 Vac (resistive load)
Dip-switch: input type, output retransmission, divider circuit settable from 1 to 256
Trimmer: pulse duration (100..500ms)
±0,01% /°C
0,05 %
DIP switch: input type, functions (relays activation,
min/max value alarm)
Trimmer:
Setpoint alarms (1..100% signal control)
Delay (0,3..30 s)
Hysteresis (2..15% for full-scale)
Power Supply
Pause (relay attracted)
Timer
±0,01% /°C
DIP switch
N. 8 timer functions / relay excitation
N. 8 time scale (50 ms..10 h)
Trimmer
Time regulation
INPUT FEATURES
Nr
Type
OUTPUT FEATURES
Nr
Type
*Available until stocks last
41
Z-LINE • PROGRAMMING & ACCESSORIES
Z-SETUP2
Z109REG2 Configuration Software
• Help on line for DIP-switch configuration
• Download / Upload / module configuration
• Scale inversion
• Burn-out setting (positive or negative)
• Digital filter insertion
• Square root exctraction
• Scale conversion
• Start / end scale, digital filter
• Square root extraction
• Burn-out setting (positive or negative)
• Rejection Network Frequency 50/60 Hz
• Sampling time setting / Resolution
• 3 / 4 wires resistance measure
ORDER CODES
Z-SETUP2
Programming software Z109REG2 (free on the website www.seneca.it)
S-TOOL
Configuration KIT
• Configuration Software on CD
• Programming cable
TEST-3
Handheld multimeter – Z109REG2 Configuration
with OLED display
. Accuracy: 0,1%
• Input/Output Setting parameters, range, Z109REG2
alarms
• Signal Generation / Measuring of Voltage (0-10 V) and
Current (0-20 mA) Signals
• OLED Display 128 x 64 points
• Batteries NiMh, type AA 2.650 mAh (20 h)
ORDER CODES
ORDER CODES
Programming Kit includes of Z-PROG, Z-SETUP, Z-SETUP2, libraries
Z-4AI-D, Z-4TC-D, Soft2000DOS/WIN, cable PM001601
Multimeter – Z109REG2 Configuration with OLED display
Calibration Service (SIT referred)
Precision kit with Z109REG2 programming cable and precision probes set
KT120-TOOL
S117P
T120 & K120RTD Configuration tool
Asynchronous RS232-TTL/USB serial converter
Configuration Kit for T120 and K120RTD complet of
S117P (USB – RS232/TTL Converter), PM002411
(S117P cable connection) – T120, KT120
(Programming software)
• Compliant with Windows (Xp, Vista, Xp Embedded, CE
.Net), Mac OS (8, 9, X), Linux (2.24.0)
• Isolation USB / RS232: 1.500 V
• Power Supply: loop powered from PC USB port
• Dimensions: 90 x 50 x 25 mm
• Standard USB 1.0, 1.1, 2.0
ORDER CODES
KT120-TOOL
ORDER CODES
T120 e K120RTD Configuration Kit
S117P
Z-POWER
Voltage transformer with output at 19 Vac (DIN rail mounting)
Asynchronous RS232-TTL/USB serial converter
PROGRAMMING CABLES
Programming cables
• Primary Voltage 230 (115) Vac ± 10%
• Box in fiberglass auto-estinguish (V-0)
• Protection by thermo-fuse
• Dimensions 3 DIN modules(15 VA),
5 DIN modules (25 VA)
• IP 40
ORDER CODES
ORDER CODES
Z-POWER 230-15VA
Z-POWER 230-25VA
Z-POWER 115-15VA
Voltage Transformer 19 Vac, 230-15 VA
Voltage Transformer 19 Vac, 230-25 VA
Voltage Transformer 19 Vac, 115-15 VA
PM001601
PM001970
PM002240
Programming serial Cables (Z109REG, Z109REG2, Z203, Z-4AI-D, Z-SG, Z4TC-D, Z-3AO, Z-8AI, Z-8TC) (jack / DB9F)
Serial cable RS232 (K107B) (free wires / DB9F)
Programming Z109REG/ Z109REG2 / TEST-3 (jack / jack)
MEASUREMENT
DEVICES
S-TOOL
TEST-3
/T
TEST-3-PK
CONVERTERS
AND INTERFACES
Programming software Z109REG (free on the website www.seneca.it)
DIGITAL
DISPLAYS
ORDER CODES
Z-SETUP
INDUSTRIAL I/O’S
AND TELECONTROL
Z-SETUP
Z109REG Configuration Software
42
CONVERTERS AND INTERFACES
S-LINE • ISOLATORS – ANALOG CONVERTERS
S109REG
S109S
DC Current/Voltag
isolator/converter
DC Current isolator
S102
*
S109PT
*
Ohm to DC Current/Voltage PT100 to DC Current/Voltage
isolator/converter
isolator/converter
ORDER CODES
Models
S109REG-1-ST (power supply 115/230 Vac)
S109REG-1-X7 (with input for tacho generator 0..100 / 200 Vdc)
S109S-1-ST (power supply 115/230 Vac)
S102-1-ST (power supply 115/230 Vac)
S109PT-1-ST (power supply 115/230 Vac)
GENERAL FEATURES
Power Supply
Power transducers
Max consumption
Galvanic Isolation
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
3,5 VA
4.500 Vac
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
1,5 VA
4.500 Vac
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
3,5 VA
4.500 Vac
Status indicators
Protection degree
Electrical Connections
Accuracy
Linearity
Thermal stability
Operating Temperature
Dimension (w x h x d)
Weight
Enclosure
Mounting
Dip-switch
Trimmer
Certification
Norms
Power Supply
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
±0,25%
±0,05%
±0,01% /°C
-10..+60 °C
70 x 95 x 72 mm
300 g
Type DIN 4 self-extinguishing Noryl V0
On 35 mm rail (DIN 46277)
Input range and Output type
Zero and Span Input
CE
EN 50081-1, EN 50082-2, EN 61010-1
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
1,5 VA
4500 Vac (from/to power supply)
2000Vac (input/output)
Power Supply
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
±0,25%
±0,05%
±0,01% /°C
-10..+60 °C
35 x 95 x 72 mm
200 g
Type DIN 2 self-extinguishing Noryl V0
On 35 mm rail (DIN 46277)
Power Supply
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
±0,25%
±0,05%
±0,01% /°C
0..+50 °C
52,5 x 95 x 72 mm
300 g
Type DIN 3 self-extinguishing Noryl V0
On 35 mm rail (DIN 46277)
Input range and Output type
Zero and Span Input
CE
EN 50081-1, EN 50082-2, EN 61010-1
Power Supply
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
±0,25%
±0,05%
±0,01% /°C
-10..+60 °C
70 x 95 x 72 mm
400 g
Type DIN 4 self-extinguishing Noryl V0
On 35 mm mounting rail (DIN 46277)
Input range and Output type
CE
EN 50081-1, EN 50082-2, EN 61010-1
CE
EN 50081-1, EN 50082-2, EN 61010-1
INPUT FEATURES
Number
Type
1
CURRENT: 0..20, 4..20 mA not standard
signals between ±14 mA and span between
2 and 20mA
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc not
standard signals between ±7 V and span
between 1 and 10 V (0..100/200 Vdc, X7
version)
Impendance: Current 100 Ω, Voltage 1 MΩ
1
CURRENT: 0..20mA and 4..20mA (active/passive)
Input impedance 20 Ω
1
1
POTENTIOMETER:
PT100 2,3 wires
Measure Range: 0..300 / 0..500 / 0..1000 Ω Measure Range: 0..100 / 0..200 / 0..400 °C
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc
Impedance: Current 800 Ω, Min.Voltage
Load: 1 KΩ
1
CURRENT: 0..20mA and 4..20mA (active/passive)
Max Current load: 900 Ω
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc
Impedance: Current 800 Ω, Min.Voltage
Load: 1 KΩ
OUTPUT FEATURES
Number
Type
*Available until stocks last
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc
Impedance: Current 800 Ω, Min.Voltage
Load: 1 KΩ
43
S104
*
DC Current/Voltage
to frequency
isolator/converter
S111
S170
Frequency to DC
Current/Voltage
isolator/converter
*
S190
S2000
DC Current/Voltage
duplicator/isolator
DC Current/Voltage
adder/subtractor
Microprocessor
Calculation Module
ORDER CODES
S104-1-ST (115 / 230 Vac)
S111-1-ST (115 / 230 Vac)
S170-1-ST (115 / 230 Vac)
S190-1-ST (115 / 230 Vac)
S2000-1-ST (115 / 230 Vac)
S2000-23-ST (24 Vac/dc)
S-TOOL (Configuration Kit)
Power Supply
Power transducers
Max consumption
Galvanic Isolation
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
1,5 VA
4.500 Vac
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
3,5 VA
4500 Vac (from/to power supply)
200Vac (input/output)
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
1,5 VA
4500 Vac (from/to power supply)
200Vac (input/output)
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
3,5 VA
4.500 Vac
Status indicators
Power Supply
Pulses on output
Protection degree
Electrical Connections
IP20
Screw-fit removable terminals for
wires up to 2,5 mm2
115 / 230 Vac ±10%, 50-60 Hz
20 Vdc (not regulated)
3,5 VA
4500 Vac (from/to power supply)
200Vac (input/output)
Power Supply
Input frequency <3% e.s.
Input frequency< 90% e.s.
IP20
Screw-fit removable terminals for
wires up to 2,5 mm2
Models
Programming & Accessories
INDUSTRIAL I/O’S
AND TELECONTROL
S-LINE • ISOLATORS – PULSE CONVERTERS AND SIGNAL PROCESSORS
Mounting
DIP switch
Trimmer
±0,1%
±0,005% /°C
-10..+60 °C
52,5 x 95 x 72 mm
300 g
Type DIN 3 self-extinguishing
Noryl V0
On 35 mm rail (DIN 46277)
Input type, integer coefficient
±0,005% /°C
-10..+60 °C
105 x 95 x 72 mm
450 g
Type DIN 6 self-extinguishing
Noryl V0
On 35 mm rail (DIN 46277)
Input frequency, output type
Full Scale
±0,5%
±0,01% /°C
-10..+60 °C
70 x 95 x 72 mm
300 g
Type DIN 4 self-extinguishing
Noryl V0
On 35 mm rail (DIN 46277)
Input - output type
IP20
Screw-fit removable terminals for
wires up to 2,5 mm2
±0,25%
±0,05%
±0,01% /°C
-10..+60 °C
70 x 95 x 72 mm
300 g
Type DIN 4 self-extinguishing
Noryl V0
On 35 mm rail (DIN 46277)
Input - output type
Span A / B (weight for
adding/difference) inputs
Software
Certification
Norms
SOFT-200 (programming software,
instruction list)
CE
EN 50081-1, EN 50082-2, EN
61010-1
CE
EN 50081-1, EN 50082-2, EN
61010-1
CE
EN 50081-1, EN 50082-2, EN
61010-1
CE
EN 50081-1, EN 50082-2, EN
61010-1
CE
EN 50081-1, EN 50082-2, EN
61010-1
1
CURRENTE: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10
Vdc
Impendance: Current 250 Ω,
Voltage 1 MΩ
1
reed contact, 2 and 3 wires npn
sensor, pnp sensor with 24 Vdc,
NAMUR sensor,24 Vdc sensor,
photoelectric sensor.
Max frequency : 680 Hz
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10
Vdc
Impendance: Current 1000 Ω,
Voltage 1 MΩ
2
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10
Vdc
Impendance: Current 1000 Ω,
Voltage 1 MΩ
6
2 Digital (open contact voltage 5
V, close contact current 1 mA)
• 4 Analogue (0..20, 4..20
mA),Max load resistance 100 Ω
1
NPN open collector, 300 mA 30
Vdc (opt. relay), pulse duration 40
ms
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5 (0..10, 2..10
opt.) Vdc
Impendance: Current 800 Ω,
Min.Voltage Load: 1 KΩ
2
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10
Vdc
Impendance: Current 800 Ω,
Min.Voltage Load: 1 KΩ
1
CURRENT: 0..20, 4..20 mA active/passive
VOLTAGE: 0..5, 1..5, 0..10, 2..10
Vdc
Impendance: Current 800 Ω,
Min.Voltage Load: 1 KΩ
6
• 4 digital (max 300 mA, 30 Vdc)
• 2 analogue (0..20, 4..20 mA),
max resi stance load 300 Ω
DIGITAL
DISPLAYS
Accuracy
Linearity
Thermal stability
Operating Temperature
Dimension (w x h x d)
Weight
Enclosure
IP20
Screw-fit removable terminals for
wires up to 2,5 mm2
Power Supply
Data reception
Data transmission
IP20
Screw-fit removable terminals for
wires up to 2,5 mm2
±0,1%
±0,05%
±0,01% /°C
-10..+60 °C
157,5 x 95 x 72 mm
500 g
Type DIN 9 self-extinguishing
Noryl V0
On 35 mm rail (DIN 46277)
CONVERTERS
AND INTERFACES
GENERAL DATA
OUTPUT DATA
Number
Type
*Available until stocks last
MEASUREMENT
DEVICES
INPUT DATA
Number
Type
44
CONVERTERS AND INTERFACES
S-LINE • ISOLATORS – RELAY CONDITIONERS
S112A•S112D•S112M
S113S•S113D•S113T
Amplifiers for ON/OFF
sensors
Trip alarm units
for analofue signals
*
S105
S108
Control relay for singlephase voltage
Control for single-phase
alternate current
with threshold
ORDER CODES
Models
S112A-1-ST (115/230 Vac, 1 input, 1 relay
output)
S112D-1-ST (115/230 Vac, 2 inputs, 2 relay
outputs)
S112M-1-ST (115/230 Vac, 1 input, 5 relay
outputs)
S112M-1-ST (115/230 Vac, 1 input, 5 relay
outputs)
S112M-23-ST (24 Vac/dc, 1 input,5 relay
outputs)
S113S-1-ST (115/230 Vac, 1 relay output)
S113D-1-ST (115/230 Vac, 2 relay outputs)
S113T-1-ST (115/230 Vac, 3 relay outputs)
S105CS1-B (230 V single-phase, output powered) S108
S105CS1-C (230 V, SPDT output)
S105TCN-1 (380 V, three phase, SPDT 5A output)
S105TCN-2 (230 V, three phase, SPDT 5 A output)
S105TCS-1 (380 V, three phase, SPDT 10 A output)
S105TCS-2 (230 V, three phase, SPDT 10 A output)
S105TCS-3 (400 V, SPDT 10 A output)
115/230 Vac ± 10%, 50/60 Hz; 24 Vac/dc
(S112M-23-ST)
20 Vdc (not regulated)
1,5 VA
115/230 Vac ± 10%, 50/60 Hz; 24 Vac
230 Vac (single phase)
230 – 400 Vac 50 Hz (three phase)
115 / 230 Vac
2 VA
1,5 VA
4.500 Vac
4.500 Vac
Network presence
Delay in recovering
Alarm
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
Power Supply
Alarm relay
GENERAL DATA
Power Supply
Power transducers
Max consumption
Galvanic Isolation
Status indicators
Protection degree
Electrical Connection
Linearity
Thermal stability
Operating Temperature
Dimension (w x h x d)
Weight
Enclosure
Mounting
DIP switch
Trimmer
Certification
Norms
4.500 Vac
2.000 vac (input/output S112M)
Power Supply input/pulses output
20 Vdc (not regulated)
1,5 VA (S113S)
3,5 VA (S113D, S113T)
4.500 Vac
Power Supply
Alarms
IP20
IP20
Screw-fit removable terminals for wires up to 2,5 mm2 Screw-fit removable terminals for wires up to 2,5 mm2
IP20
Screw-fit removable terminals for wires up to 2,5 mm2
±0,1%
±0,005% /°C
0..+60 °C
52,5 x 95 x 72 mm
-10..+60 °C
52,5 x 95 x 72 mm (S112A)
70 x 95 x 72 mm (S112D, S112M)
250 g (S112A)
270 g (S112D)
280 g (S112M)
Type DIN 3 (S112A) – 4 (S112D, S112M)
self-extinguishing Noryl V0
On 35 mm mounting rail (DIN46277).
Divider circuit
Pulse lenght
CE
EN 50081-1, EN 50082-2, EN 61010-1
-10..+60 °C
52,5 x 95 x 72 mm (S113S)
70 x 95 x 72 mm (S113D, S113T)
290 g (S113S)
280 g (S113D)
350 g (S113T)
Type DIN 3 (S113S) – 4 (S113D, S113T)
self-extinguishing Noryl V0
On 35 mm mounting rail (DIN46277).
Input and alarm type
Threshold, delay, histeresys
CE
EN 50081-1, EN 50082-2, EN 61010-1
-10..+60 °C
52,5 x 95 x 72 mm (S105CS, S105TCS)
70 x 95 x 72 mm (S105TCN)
250 g
1, 2
Reed contact, 2 and 3 wires npn sensor
with 12 and 24 Vdc power supply, 2 and 3
wires pnp sensor with 24 Vdc power supply,
NAMUR sensor, 24 Vdc pulse, photoelectric
sensor and HaIl effect sensor.
Input frequency: max. 400 Hz,
minimum pulse duration 2 ms
1
CURRENT: 0..20, 4..20 mA
VOLTAGE: 0..5, 1..5, 0..10, 2..10 Vdc
Impendance: Current 250 Ω, Voltage 1 MΩ
1
Single phase Voltage 230 V (S105 TCS)
Three phase Voltage 230 V
Three phase Voltage 380 V
Three phase Voltage 400 V
1, 2, 5
S112A: 1 SPDT relay, 5 A 250 Vac (resistive load)
S112D: 2 SPDT relays, 5 A 250 Vac
(resistive load)
S112M: 5 SPST reed relays, 100 Vdc/50
Vac (resistive load)
1, 2, 3
S113S: 1 SPDT relay, 5 A 250 Vac (resistive load)
S113D: 2 SPDT relays, 5 A 250 Vac
(resistive load)
S113T: 5 SPDT relays, 5 A 250 Vac
(resistive load)
1
1
S105CS: 1 SPST relay 10 A, 250 Vac (resi- 1 SPDT relay 5 A, 250 Vac (resistive load)
stive load)
S105TCN: 1 SPDT relay 5 A, 250 Vac (resistive load)
S105TCS: 1 SPDT relay 10 A, 250 Vac
(resistive load)
Type DIN 3 (S105CS, S105TCS) – 4
(S105TCN) self-extinguishing Noryl V0
On 35 mm mounting rail (DIN46277).
Threshold, recovering time
CE
EN 50081-1, EN 50082-2, EN 61010-1
350 g
Type DIN 3 self-extinguishing Noryl V0
On 35 mm mounting rail (DIN46277).
Memory
Threshold, delay, histeresys
CE
EN 50081-1, EN 50082-2, EN 61010-1
INPUT DATA
Number
Type
1
External CT for loads > 5 A
OUTPUT DATA
Number
Type
*Available until stocks last
45
S50
S100S
S109S
S109REG
Power Supply
for current loop
Dual Power Supply
for current loop
Galvanic Isolation for
0/4..20 mA current loop
V-I / V-I Converter
with galvanic Isolation
ORDER CODES
Models
S50-1-ST (115 / 230 Vac)
S50-3-ST (24 Vac)
S100S-1-ST (115/ 230 Vac)
S100S-3-ST (24 Vac)
S109S-1-ST (115/230 Vac)
S109REG-1-ST (115/230 Vac)
115/230 Vac ± 10%, 50/60 Hz; 24 Vac
1,5 VA
Input protected against line overvoltages
by a varistor isolation input // output at
4.500 Vac.
Output protected against short-circuit
115 / 230 Vac ± 10%, 50 / 60 Hz
3,5 VA
Input protected against line overvoltages
by a varistor isolation input // output at
4.500 Vac.
Output protected against short-circuit
115 / 230 Vac ± 10%, 50 / 60 Hz
1,5 VA
Galvanic isolation between power supply
// input-output 4500 Vac, input//output
2000 Vac
115 / 230 Vac ± 10% 50 / 60 Hz
3,5 VA
Galvanic isolation between power supply
// input //output 4500 Vac,
Current loop: 0 - 20, 4 - 20 mA
Input resistance: 20 ohm
Input Power Supply: 20 Vdc
(not regulated)
Settable by DIP-switch
• CURRENT: 0 - 20, 4 - 20 mA;
ZERO: -14..+14 mA
SPAN: 2..20 mA
• VOLTAGE: 0-5, 1-5, 0-10, 2-10 Vdc;
ZERO: -7..+7 Vdc
SPAN: 1..10 Vdc
• Input impedance: 100 ohm (current), 1
Mohm (voltage)
Settable by DIP-switch of
• CURRENT: 0 - 20, 4 - 20 mA;
• VOLTAGE: 0-5, 1-5, 0-10, 2-10 Vdc
• Max load: Current 0 – 800 Ohm,
Voltage > 1 Kohm
INDUSTRIAL I/O’S
AND TELECONTROL
S-LINE • REGULATED POWER SUPPLY (FOR CURRENT LOOP)
Nr1 Regulated 24 Vdc, 40mA
Linearity
Temperature derivation
Operating Temperature
Humidity
Enclosure
< ± 0,25%
< 100 ppM/°C
-10..+ 60°C
-10..+ 60°C
-10..+ 60°C
90% at @ 40°C (non condensing)
90% @ 40°C (non condensing)
90% @ + 40°C (non condensing)
The self-extinguishing Noryl case is the The self-extinguishing Noryl case is the The self-extinguishing Noryl case is the
width of 2 DIN modules and designed to width of 3 DIN modules and designed to width of 2 DIN modules and designed to
fit on 35 mm mounting rail (DIN46277). fit on 35 mm mounting rail (DIN46277). fit on 35 mm mounting rail (DIN46277).
35 x 95 x 72 mm
52,5 x 95 x 72 mm
35 x 95 x 72 mm
150 g
300 g
200 g
Dimension (w x h x d)
Weight
Nr 2 Regulated and galvanically isolated Current loop: 0 - 20, 4 - 20 mA
24 Vdc 50 mA
Max load: 900 ohm
Power supply (output): 20 Vdc
(not regulated)
< ± 0,25%
< 100 ppM/°C
-10..+ 60°C
90% @ + 40°C (non condensing)
The self-extinguishing Noryl case is the
width of 4 DIN modules and designed to
fit on 35 mm mounting rail (DIN46277).
70 x 95 x 72 mm
300 g
DIGITAL
DISPLAYS
Output
MEASUREMENT
DEVICES
Input
CONVERTERS
AND INTERFACES
GENERAL DATA
Power Supply
Max consumption
Isolation and protection
CONVERTERS AND INTERFACES
46
S-LINE • REGULATED INDUSTRIAL POWER SUPPLY
*
S70E
S90
DC /DC Converter
Switching
Power Supply
S200
S200REG
Dual Regulated
Power Supply
Switching Power Supply
(adjustable)
ORDER CODES
Models
S70E (110 Vdc)
S90-1-ST (115 / 230 Vac)
S200-1-ST (115 / 230 Vac)
S200REG/16 from 14 to 18 Vdc, max
current 500 mA
S200REG/24 from 22 to 26 Vdc, max
current 350 mA
GENERAL DATA
Power Supply
110 Vdc ± 10%
115 / 230 Vac ± 10% 50 / 60 Hz
115 / 230 Vac ± 10% 50 / 60 Hz
115 / 230 Vac ± 10% 50 / 60 Hz
30 W
35 VA
Galvanic isolation input//output @2.500 V Input protected against line overvoltages
by a varistor isolation input // output at
4.500 Vac.
Output protected against short-circuit or
overload
Regulated 24 Vdc 1A
Regulated 24 Vdc 1,3A
7,5 VA
Input protected against line overvoltages
by a varistor isolation input // output at
4.500 Vac.
Output protected against short-circuit or
overload
+ 15 Vdc 350 mA
- 15 Vdc 75 mA
10 VA
Input protected against line overvoltages
by a varistor isolation input // output at
4.500 Vac.
Output protected against short-circuit or
overload
S200REG/16 : 14 / 18 Vdc 500 mA
S200REG/24 : 22 / 26 Vdc 350 mA
- 10..+ 60 °C
90% @ 40 °C
(non condensing)
The self-extinguishing Noryl case is the
width of 4 DIN modules, with heatsink on
the upper side, and is designed to fit on
35 mm mounting rail (DIN46277).
70 x 95 x 105 mm
1 kg
- 10..+ 60 °C
90% @ 40 °C
(non condensing)
The self-extinguishing Noryl case is the
width of 4 DIN modules, with heatsink on
the upper side, and is designed to fit on
35 mm mounting rail (DIN 46277).
70 x 95 x 105 mm
0,7 Kg
- 10..+ 60 °C
90% @ 40 °C
(non condensing)
The self-extinguishing Noryl case is the
width of 4 DIN modules, with heatsink on
the upper side, and is designed to fit on
35 mm mounting rail (DIN 46277)
70 x 95 x 105 mm
0,7 Kg
Max consumption
Isolation and protection
Output
Operating Temperature
Humidity
Enclosure
Dimension (w x h x d)
Weight
*Available while stocks last
- 10..+ 60 °C
90% @ 40 °C
(non condensing)
The self-extinguishing Noryl case can be
mounted on the back of the panel by
means of screws or on 35 mm mounting
rail (DIN46277).
90 x 120 x 113 mm
1,5 Kg
47
S-LINE • REGULATED INDUSTRIAL POWER SUPPLY (PANEL MOUNTING)
ORDER CODES
Models
GENERAL DATA
Power Supply
Transducers Power Supply
Max consumption
Input
Output
Display
Accuracy
Stability on changes of power
supply
Rejection of frequency Network
Operating Temperature
Storage temperature
Humidity
Enclosure
Dimension (w x h x d)
Weight
S200G-1-ST (230 Vac)
Signal Generator 0 – 20 mA
S200D (115 / 230 Vac)
3 ½ Digits Display with Power Supply
230 Vac ± 10% 50 - 60 Hz
115-230 Vac ± 10% 50 - 60 Hz
+15 Vdc 350 mA e -15 Vdc 75 mA
11 VA
CURRENT: 0 - 20, 4 - 20 mA
VOLTAGE: 0 - 5, 1 - 5 Vdc
IMPEDANCE: 100 ohm for current input, 1 Mohm for
voltage input
Dual Regulated Power Supply +15 Vdc (350 mA), -15
Vdc 75 (mA)
40 dB
-10..+ 60 °C
-25..+ 60 °C
90% @ 40 °C (non condensing)
"V0" self-extinguishing NORYL, shock-proof cabinet,
suitable for front panel installation, dimension 96x96 mm
96 x 96 x 117 mm
1 Kg
40 dB
-10..+ 60 °C
-25..+ 60 °C
90% @ 40 °C (non condensing)
"V0" self-extinguishing NORYL, shock-proof cabinet,
suitable for front panel installation, dimension 96x96 mm
96 x 96 x 117 mm
0,8 Kg
S200DP (115 / 230 Vac)
3 ½ Digits Display with Power Supply and Setpoint
115-230 Vac ± 10% 50 - 60 Hz
+15 Vdc 350 mA e -15 Vdc 75 mA
11 VA
11 VA
CURRENT: 0 - 20, 4 - 20 mA
VOLTAGE: 0 - 5, 1 - 5 Vdc
IMPEDANCE: 100 ohm for current input, 1 Mohm for
voltage input
0/4 - 20 mA, Voltage loop at 24 Vdc
Dual Regulated Power Supply +15 Vdc (350 mA), -15
Vdc 75 (mA)
Set point 0/1 – 5 Vdc (potentiometer)
3 1/2 digits display, high brightness red led, 14 mm high 3 1/2 digits display, high brightness red led, 14 mm high 3 1/2 digits display, high brightness red led, 14 mm high
Zero and span display settable by multi turn trimmer
Zero and span display settable by multi turn trimmer
Zero and span display settable by multi turn trimmer
Display range from -999 to 1999
Display range from -999 to 1999
Display range from -999 to 1999
Decimal point available through jumpers
Decimal point available through jumpers
Decimal point available through jumpers
< 0,3%
< 0,3%
< 0,3%
0,01%/20%
0,01%/20%
0,01%/20%
40 dB
-10..+ 60 °C
-25..+ 60 °C
90% @ 40 °C (non condensing)
"V0" self-extinguishing NORYL, shock-proof cabinet,
suitable for front panel installation, dimension 96x96 mm
96 x 96 x 117 mm
1 Kg
INDUSTRIAL I/O’S
AND TELECONTROL
3 ½ Digits Display with Power
Supply and Setpoint adjustment
CONVERTERS
AND INTERFACES
3 ½ Digits Display
with Power Supply
S200DP
DIGITAL
DISPLAYS
Signal Generator
0 – 20 mA
S200D
MEASUREMENT
DEVICES
S200G
CONVERTERS AND INTERFACES
48
S400 • PROTECTIONS AGAINST OVERVOLTAGES
ORDER CODES
Models
S400CL
S400LV
S400HV
Electronic protections
for 4 - 20 mA current loop
Electronic protections
for mains lines up to 35 vac/dc
Electronic protections for
mains 220 vac lines
S400CL
S400HV
S400LV
1-module size box to be mounted into to 35mm bar,
DIN 46277, in UL94 V0 plastic material, with
transparent protection that can be plumbed.
< 35Vcc supply for 4-20mA current loop
1-module size box to be mounted into to 35mm bar,
DIN 46277, in UL94 V0 plastic material, with
transparent protection that can be plumbed.
low voltage lines up to 35Vdc or ac (+/-15%)
2-module size box to be mounted into to 35mm bar,
DIN 46277, in UL94 V0 plastic material, with
transparent protection that can be plumbed.
220Vac lines (+/-15%)
47V(rms) ( wire to wire )
90V ( wire to wire and wire to ground )
> 5000 A
1500 A
47V(rms) ( wire to wire )
90V ( wire to wire and wire to earth )
> 5000 A
1500 A
1A
275V(rms) (wire to wire)
470V (wire to wire and wire to earth )
> 5000 A
1500 A
6,3 A
approx. 2.2 Vdc
90 x 18.5 x 73 mm
150 gr. approx
Output Current Loop
90 x 18.5 x 73 mm
150 gr. approx
Output 24 Vdc (max 800 mA)
90 x 36 x 73 mm
200 gr. approx.
Output 230 Vac (max 5 A)
Input Current Loop
Input 24 Vdc
Input 230 Vac
GENERAL DATA
Enclosure
Rated Voltage
Operating voltage
Discharge voltage
Discharge current
Breaking capability
Max load
Loop voltage drop
Dimension (w x h x d)
Weight
Electrical Connections / front view
Application schemes
49
SPECIFICHE TECNICHE
Z109REG
CODICI DʼORDINE
• Z109REG (24 Vdc/ac)
• Z109REG-ER (24 Vdc/ac) - estrazione di radice già programmata
ELETTRICHE
Alimentazione
3
CONFIGURAZIONE E NORME
Programmazione software
• Lettura, configurazione, download e salvataggio
DIP Switch
• Tipo, zero e span ingresso
• Tipo uscita
Norme CE
EN50081-2, EN50082-2, EN61010-1
COMUNICAZIONE, ELABORAZIONE, MEMORIA
Campionamento
3 letture al secondo
Memoria dati
EEPROM per i parametri di configurazione, tempo ritenuta 10 anni
Ingresso e uscita (tipo e range)• Termocoppia - J: -200..+1000°C; K: -200..+1300°C;
R: 50..+1750°C; S: -50..+1750°C; T: -200..+ 400°C; E: 150..+800°C; B: 0..+1800°C; N: -200..+1300 °C;
• Termoresistenza - Pt100 -200..+600 °C
• Potenziometro: 0,5..15 Kø
• Tensione (bipolari) 0..200 mV; 0..2, 0..5; 0..10 V
• Corrente (bipolari) 0..20 mA
Impedenza di ingresso
• 2.5 ø in corrente
• 1 Mø in tensione
Risoluzione di ingresso
• Termocoppia: risoluzione 5 ÌV, rilevamento
automatico interruzione TC
• Termoresistenza: misura a 3 fili, corrente di eccitazione 0.56 mA,
risoluzione 0.1 °C, rilevamento automatico interruzione cavi o RTD
• Potenziometro: fondo scala min. 500 ø, risoluzione 0,01 % ds
• Tensione :risoluzione 0.01 %ds
• Corrente: risoluzione 0.01 %ds
Impedenza di uscita
• Impedenza loop in corrente 0..600 ø
• Carico per uscita in tensione > 2.5 Kø
Risoluzione di uscita
• 0.025% per 0..20 mA / 0..10 V / 0..5 V
• 0.032% per 4..20 mA / 2..10 V / 1..5 V
Errori
• Precisione 0.2 %ds. in tensione e corrente, 0.2 % altrimenti
• Linearità: 0.05 % per ingresso in tensione, corrente e potenziometro,
0.2°C per termoresistenza, 1°C per termocoppie salvo 3°C per TCB
oltre 600°C
• Stabilità termica: 0.02%/°C
• Compensazione giunto freddo: 2°C tra 10 e 40°C
DIMENSIONI E INGOMBRI
COLLEGAMENTI ELETTRICI
Assorbimento max
Isolamento
Protezione
Alimentazione trasduttori
Indicatori di stato
Categoria di installazione
Grado di inquinamento
Grado di protezione
• 19..40 Vdc / 19 - 28 Vac, 50-60 Hz
• 9..30 Vdc (opzionale)
2.5 W
Alimentazione // ingresso // uscita: 1.500 Vac
• Ingressi: in corrente 200 mA continuativi, rimanenti 60 V continuativi
• Alimentazione e uscite: contro sovratensioni impulsive 400 W/ms
min 18 Vdc 20 mA
• Power
• Error
II
2
IP20
TERMOMECCANICHE
Temperatura
Funzionam.: 0..+ 50°C
Umidità
30..90 % a +40 °C (non condensante)
Peso
200 g circa
Custodia
Nylon 6 caricato 30 % fibra vetro – classe autoestinguenza V0
Connessioni
Morsetti estraibili polarizzati a vite per conduttori fino a 2.5 mm2
Montaggio
Guida 35 mm DIN 46277
ALIMENTAZIONE
DIGITAL
DISPLAYS
La tensione di alimentazione deve essere compresa tra 10 e 40 Vdc), o tra 12 e
28 Vac. I limiti superiori non devono
essere superati, pena gravi danni al
modulo.
INTERFACCIA SERIALE
Il collegamento per lʼinterfaccia seriale e
per lʼalimentazione del modulo è presente anche nel con-nettore sul fondo dello
strumento e ne permette il collegamento
in bus tramite lʼapposito supporto da installare nella guida DIN
USCITE
DIGITAL DISPLAYS
50
Wide range of displays
• High brightness display
• Multi-standard input
• Easy programming
DIGITAL INDICATORS
S401
S401
S311D
S200 / S201
S301
S301B
Display: 4 digit LED (+ bargraph,
S301B)
Analog input: V, mA, TC, Pt100, Ohm
Analog output: mA, V
(re-transmitted)
Nr 3 SPDT relay alarms / Nr 4 open
collector alarms (optional)
Dimension: 96x48x148 mm (S301);
96x96x148 mm (S301B)
Power supply: 115-230 Vac or 24
Vac/dc
Power transducers
S200
S201
Display: 3 ½ digit LED
Input: mA, V
Potentiometer setpoint
(DP versions)
Dimension: 96x48x117 mm
Power supply: 115-230 Vac
Power transducers
Display: 4, 6, 8, 4+7 digit LED
Digital input: contact, npn, pnp, namur, photoelectric, variable
reluctance, 24 V pulse, TTL
Re-transmitted analog output and open collector digital
output
Input measures totalization – integration
Dimension: 96x48x98 mm
Power supply: 80-265 Vac; 10-40 Vdc / 19-28 Vac
Power transducers
Optional board: nr 2 SPDT relay alarm, ModBUS RTU
interface, reset digital input
S301 / S301B
S311A
Display: 4, 6, 8, 4+7 digit LED
Analog input: mA, V, Ohm, Pt100, TC
Re-transmitted analog output and open collector digital
output
Input measures totalization – integration
Dimension: 96x48x98 mm
Power supply: 80-265 Vac; 10-40 Vdc / 19-28 Vac
Power transducers
Optional board: nr 2 SPDT relay alarms, ModBUS RTU
interface, reset digital input
Display: 2,7” OLED, 128x64 pixel
ModBUS RTU interface
Dimension: 96x48x40 mm
Power supply: 10-40 Vdc / 19-28 Vac
S311D
S311A
S310 / S320A
S310
S320A
Display: 3 ½ digit LED
Analog input: V, mA, TC, Pt100
Analog output: mA (optional)
Nr 1 or 2 SPDT relay alarms
Dimension: 96x48x148 mm;
96x96x148 mm
Power supply: 115-230 Vac or 24
Vac/dc
Power transducers
51
Display: 6, 8 digit LED
Input: 1-CH pulse sensor (reed, npn,
pnp, namur, 24 Vdc pulse, photoelectric), max frequency 450 Hz
Bidirectional counter (S144B)
Dimension: 96x48x148 mm
Power supply: 115-230 Vac; 24 Vac/dc
S144I
S164
S164
Display: 6, 8 digit LED
Input: 1-CH mA, V
Re-transmitted output: 1-CH pulse (npn
open collector)
Dimension: 96x48x148 mm
Power supply: 115-230 Vac; 24 Vac/dc
Power transducers
Display: 3 ½ digit (indicator) + 7 digit
(totalizer)
Input: 1-CH mA, V
Dimension: 96x48x148 mm
Power supply: 115-230 Vac; 24 Vac/dc
S21
S30
BATCH CONTROLLERS
S20N
S20N
Display: 5 digit double LED
Digital input: 3-CH (control: start, stop,
reset) + 1-CH (sensor: reed, npn,
namur, hall effect, photoelectric, max
frequency 1 kHz)
Digital output: 2-CH SPDT relay
Dimension: 144x72x130 mm
Power supply: 115-230 Vac; 24 Vac/dc
Versions: standard, Ex, IP65
S21
Display: 5 digit double LED
Digital input: 3-CH (control: start, stop,
reset) + 1-CH (sensor: reed, npn,
namur, hall effect, photoelectric, max
frequency 1 kHz)
Digital output: 2-CH SPDT relay
Self-powered clock
Dimension: 144x72x130 mm
Power supply: 115-230 Vac; 24 Vac/dc
Versions: standard, Ex, IP65
PUMP CONTROLLER
S6000
S30
Display: 5 digit double LED
Digital input: 3-CH (control: start, stop,
reset) + 1-CH (sensor: reed, npn,
namur, hall effect, photoelectric, max
frequency 1 kHz)
Digital output: 2-CH SPDT relay
Serial interface (option)
Parallel interface for printer
Dimension: 144x144x130 mm
Power supply: 115-230 Vac; 24 Vac/dc
Versions: standard, IP65
CONVERTERS
AND INTERFACES
S114
S114B
S144I
OPERATOR PANELS
S6000
LCD back-lightened display: 2 raws x 16 chars
Input: 6-CH digital (contact), 2-CH analog (mA)
Output: 6-CH SPST relay (actuators), 1-CH SPDT relay
(signalling), 1-CH open collector (contact), 2-CH analog (mA, V)
Interface: isolated RS232
Instruction list programming
Dimension: 144x72x121 mm
Power supply: 115-230 Vac; 24 Vac/dc
Power transducers: 24 Vdc, 30 mA (isolated)
ZTOP
ZTOP
Graphic display: LCD 3,8” / 5,6”,
STN 5,6”
Resistive touchscreen
Resolution 320x240 pixel
Alarms, events log control
Dimensions: 149x109x61 mm
(ZTOP03); 187x147x79 mm
(ZTOP05, ZTOP11)
MEASUREMENT
DEVICES
S114 / S114B
DIGITAL
DISPLAYS
TOTALIZERS
INDUSTRIAL I/O’S
AND TELECONTROL
• Vac / Vdc power supply
• Power transducers
• Calibration service
DIGITAL DISPLAYS
52
• HIGH BRIGHTNESS: 70 cd/m2
• HIGH DEFINITION: 128x64 pixel
• SPACE SAVING: 96x48x40 mm
• VISUALIZATION: up to 30 measurements (float, integer, boolean)
• PROGRAMMING: via software or front key menu
• MASTER FUNCTIONS: 27 math functions, 20 readings from slave modules,
10 writings on slave devices, alarms control on threshold
• REDUCED CABLING: Nr. 2 RS485 ModBUS interfaces (1 Master / 1 Slave)
S401
OLED display
with ModBUS
interface
Temperature control
Z-4RTD
PLC local control
Z-4TC
Z-PC Line I/O modules
PLC
S401
ModBUS RTU RS485,
max 1.200 m
ModBUS RTU
Master
RS485, max
1.200 m
ModBUS RTU
Slave
Sensors / Alarms
Signal wireless re-transmission
Short range
300 m
10 mW
100 kbps
434 – 869 Mhz
AO / DO
RS485
ModBUS RTU
Process control
AI / DI
ModBUS RTU
Master RS485, max
1.200 m, 32 nodi
Flow transmitter with
analog or pulse outpu
Transmitters with
ModBUS RS485 output
Level transmitters
with analog ouput
53
4 digit
6 digit
8 digit
4+7 digit
INDUSTRIAL I/O’S
AND TELECONTROL
CUSTOM DISPLAY
Active current
mA (2 wire)
TC
Potentiometer (R)
Voltage (V)
Pt100
• Resolution 14 bit
• Sampling frequency 2 Hz
• Response time 700 ms
DIGITAL INPUTS (S311D)
Reed
Npn 2 wire
Npn 24 V
(3 wire)
Pnp 24 V
(3 wire)
Namur
Namur
Hall
24 V
TLL
Variable
reluctance
• Resolution < 0,005%
• Frequency range 0,99915 Hz – 10 kHz
• Response time 5 ms
OUTPUTS
ANALOG
Start and full scale voltage
(0..10 V) or current settable
DIGITAL
Pulse re-transmission, open
collector Imax=50 mA,
Vmax=30 V
RELAY
Nr. 2 SPDT 220 Vac relay
output, alarm signalling
SERIAL
Nr. 1 ModBUS RTU Slave /
RS485 interface
DIGITAL
DISPLAYS
Current mA
Modular indicators
totalizers
MEASUREMENT
DEVICES
ANALOG INPUTS (S311A)
CONVERTERS
AND INTERFACES
S311A • S311D
DIGITAL DISPLAYS
54
S-LINE – NEW GENERATION LED / OLED DIGITAL DISPLAY
S401
ModBUS RTU indicator
with OLED 2,7" display
S311A
Indicator-totalizer with universal
analog input
S311D
Indicator-totalizer with digital /
frequency input
GENERAL DATA
10-40 Vdc / 19-28 Vac
80-265 (H version); 10-40 Vdc / 19-28 Vac (L version)
Max 18 V, 25 mA
3W
1.500 Vac
ModBUS RTU slave (optional board)
80-265 (H version); 10-40 Vdc / 19-28 Vac (L version)
Max 18 V, 25 mA
3W
1.500 Vac
ModBUS RTU slave (optional board)
EEPROM 10 years
EEPROM 10 years
LED, 4, 6, 8, 11 (4+7) digit
2 alarms LED
3 menu keys
Over-range, burn-out
0,1%
0,101% /K
0,2°C (Pt100)
0,5°C (TC J,K,E,T,N)
1°C (TC R, S)
2°C (TC B)
0,05% (0-10 V, 0-20 mA)
±1,5°C
LED, 4, 6, 8, 11 (4+7) digit
2 alarms LED
3 menu keys
Over-range, burn-out
1
Voltage 0-10 V
Active / passive current (0-20 mA)
Potentiometer (1-100 k)
Pt100 2,3,4 wire (IEC 751 / EN 60751-ITS90)
Thermocouple J,K,R,S,T,B,E,N
14 bit
20 ms (min sample time)
Digital input / front key
1
Contact, reed, npn 2-3 wire, pnp 3 wire – 24 Vdc power
supply
Namur, photoelectric, variable reluctance sensor
24 V pulse, TTL
1
0-10 V (min 1K)
0-20 / 4-20 mA (max 500 ohm)
10.000 points
Nr 1 RS485 ModBUS RTU slave serial output + nr 2
SPDT relay 220 Vac 5 A (resistive), 2 A (inductive)+ nr1
reset digital input
1
0-10 V (min 1K)
0-20 / 4-20 mA (max 500 ohm)
10.000 points
Nr 1 RS485 ModBUS RTU slave serial output + nr 2 SPDT
relay 220 Vac 5 A (resistive), 2 A (inductive)+ nr1 reset digital
input
-10..+60°C
PPO self-exinguished, panel mount, DIN 43700
IP65
Removable terminals
96x48x40 mm
91x45 mm
200 g
-10..+60°C
PPO self-exinguished, panel mount, DIN 43700
IP65
Removable terminals, step 3,5 – 5,08 mm
96x48x98 mm
91x45 mm
200 g
-10..+60°C
PPO self-exinguished, panel mount, DIN 43700
IP65
Removable terminals, step 3,5 – 5,08 mm
96x48x98 mm
91x45 mm
200 g
Software / query
Max free settings 20 query, data management via Z-NET3
Visualization parameters, alarms, signals, timeout, reset,
trip threshold
Visualization parameters, alarms, signals, timeout, reset, trip
threshold
Settings
Communication parameters, language, contrast, brightness, range, offset, measure type
Calibration
Conformity
EN 61000-6-4/2002, EN 61000-6-2/2005, EN 61010-1/2001
yes
EN 61000-6-4/2002, EN 61000-6-2/2005, EN 61010-1/2001
yes
EN 61000-6-4/2002, EN 61000-6-2/2005, EN 61010-1/2001
Power supply
Power transducers
Max consumption
Galvanic isolation
Communication interface
1W
1.500 Vac
2 x RS485 ModBUS RTU Master / Slave
Speed 1.200..115.200 bps
RAM: 256 byte
XRAM: 4kB
Flash: 32 kB
Scratchpad: 128 byte
Memory
VISUALIZATION AND MEASURE
OLED 2,7”, 128 x 64 pixel
Display
Status indicators
Front keys
Display error
Accuracy
Thermal stability
Linearity
3 menu keys
Cold junction
Visualization
Up to 20 measures (max 3 per page) free settable
Address, parity, baud rate, response delay time, transmission delay time, data receiving timeout
RAM, 20 x 4 byte
Serial communication
Data storage
INPUT DATA
Nr
Type and range
Resolution
Frequency
Reset
0,00015 Hz – 10 kHz (response time 5 ms)
Digital input / front key
OUTPUT DATA
Nr
Type
Resolution
Optional board
THERMOMECHANICS DATA
Operating temperature
Case
Front protection
Connections
Dimension (w x h x d)
Panel dimension
Weight
SETTINGS, NORMS
ORDER CODES
Code
Model
Power supply
Code
Model
Display
Power supply
Options
S401
-L
S311A
S311D
-4 / -6 / -8 / -11
-H / -L
-O
/T
Description
ModBUS RTU indicator with OLED 2,7" display
10-40 Vdc; 19-28 Vac
Description
Indicator-totalizer with universal analog input
Indicator-totalizer with digital / frequency input
4 / 6 / 8 / 4+7 digit
80-265 Vac / 10-40 Vdc; 19-28 Vac
Optional board: RS485 ModBUS isolated serial output, 2 relay alarms, isolated digital input
Calibration service
55
S-LINE • DIGITAL INDICATORS
S301 / S301B
3 1/2 digit indicator with power
supply and control signal
S310 / S320A
4 digit digital indicators
3½ digit digital indicators
with relay alarms
GENERAL DATA
115-230 Vac ±10%, 50-60 Hz
+15 Vdc, 350 mA; -15 Vdc, 75 mA; 24 Vdc, 500 mA
11 VA
40 dB (50-60 Hz)
Power supply
Power transducers
Max consumption
Rejection
Communication interfaces
Memory
115-230 Vac ±10%, 50-60 Hz; 24 Vac/dc±10%
4 VA
115-230 Vac ±10%, 50-60 Hz; 24 Vac/dc±10%
20 Vdc, 20 mA
3,5 VA
RS232 / RS485, 9.600 bps, max 1.000 m, 31 devices
EEPROM, 10 years
INDUSTRIAL I/O’S
AND TELECONTROL
S200D / S200DP / S201D / S201DP
VISUALIZATION AND MEASURE
3 ½ digit
14 mm LED
4 digit
20 elements bargraph (50 mm)
14 mm LED
0,1% (current / voltage)
0,2% (RTD, potentiometer)
0,01%/°C
0,01%..0,5%
1°C (20-40 °C)
3 ½ digit
14 mm LED
Accuracy
0,3%
Thermal stability
Linearity
Cold junction
0,01%/°C
1
Current: 0-20, 4-20 mA
Voltage: 0-5, 1-5, 0-10, 2-10 V
1
Voltage: from 200 mV up to 4 V (4 scales)
Current: up to 20 mA
Potentiometer: up to 15 kΩ
Pt100 (-200..+650 °C)
TC J,K,R,S,T,B
3 readings per second
1
Current: 0-20, 4-20 mA
Voltage: 0-2, 0,4-2, 0-5, 1-5 Vdc (0-10. 2-10 Vdc on demand)
Pt100 (option)
TC k,J (option)
1
Accurate potentiometer setpoint (0/1-5 Vdc; 4-20 mA active)
1
Current: 0-20, 4-20 mA
Voltage: 0-5, 0-10, 1-5, 2-10 V
Da 0,025% a 0,032%
1
Current: 0-20, 4-20 mA (re-transmitted, isolated,
active / passive)
3, 4
SPDT relay 5 A – 250 Vac
Open collector 35 Vdc – 200 mA
1, 2
SPDT relay 5 A – 250 Vac (resistive load)
-10..+55°C
0..50°C
V0 Self-extinghuished Noryl shockproof
0,3%
0,01%/°C
INPUT DATA
Nr
Type
Frequency
CONVERTERS
AND INTERFACES
Display
(ANALOG) OUTPUT DATA
Nr
Type
Resolution
THERMOMECHANICS DATA
Operating temperature
Case
Front protection
Connections
Dimension (w x h x d)
Panel dimension (w x h)
Weight
-10..+60°C
V0 Self-extinghuished Noryl shockproof
IP41
Removable terminals
96 x96 x 117 mm
91 x 91 mm
750 g
96 x 48 x 148 mm (S301); 96 x 96 x 148 mm (S301B)
DIGITAL
DISPLAYS
(ALARMS) OUTPUT DATA
Nr
Type
Screw terminals
96 x 48 x 148 mm (S310); 96 x 96 x 148 mm (S320A)
500 g (S301); 600 g (S301B)
SETTINGS, NORMS
Visualization zero and span (-999..+1.999)
Decimal point
Conformity
CE
CE
ORDER CODES
Codice
Model
S200D
S200DP
S201D
S201DP
Code
Model
Power supply
Opzioni
Code
Model
Power supply
Options
Visualization zero and span (-999..+1.999), alarms
Full scale, alarms, input type, decimal point, re-transmitted
output
CE
Description
3 1/2 digit indicator, 115 / 230 Vac, Power transducers ±15 Vdc
3 ½ digit indicator, 115 / 230 Vac, Power transducers ±15 Vdc, setpoint
3 ½ digit indicator, 230 Vac, Power transducers 24 Vdc
3 ½ digit indicator, 230 Vac, Power transducers 24 Vdc, setpoint
S301
S301 B
-1-R / -23-R
-AOC-S
-AR-S
S310 / S310A / S310AA
S320A
-1-ST / -23-ST
-PT
-TC (J,K)
-R
Description
4 digit digital indicator, universal analog input, re-transmitted output
4 digit + bargraph digital indicator, universal analog input, re-transmitted output
115 / 230 Vac / 24 Vac/dc
Nr 4 open collector alarms, serial output
Nr 2 SPDT relay alarms, serial output
Description
3 ½ digit digital indicator, V,I input / + 1 SPDT alarm relay / + 2 SPDT alarm relay
115 / 230 Vac / 24 Vac/dc
Pt100 input
TC (J or K) input
Re-transmitted output
MEASUREMENT
DEVICES
Data request and write
Diagnostic and programming
Software
Front keys
Trimmer
Jumper / shunt
DIGITAL DISPLAYS
56
S-LINE • TOTALIZERS
S114 / S114B
*
Totalizers with divider
and universal input
S144I
*
Totalizer with integrator, analog
input, pulse output
S164
*
7 digit totalizer with 3 ½
digit indicator
GENERAL DATA
115/230 Vac ±50/60 Hz; 24 Vac/dc
Power supply
Power transducers
Max consumption
Data storage
3,5 VA
Rechargeable backup battery, 2 months lifetime without
network supply
115/230 Vac ±50/60 Hz; 24 Vac/dc
20 Vdc, 20 mA
3,5 VA
Rechargeable backup battery, 1 months lifetime without network supply
115/230 Vac ±50/60 Hz; 24 Vac/dc
6, 8 digit 14 mm LED
7 digit (totalizer) + 4 digit (indicator)
14 mm LED
< 0,5% (max conversion error)
3,5 VA
Rechargeable backup battery, 1 months lifetime without network supply
VISUALIZATION AND MEASURE
6 digit (14 mm) red LED
8 digit (9 mm) red LED
Display
Accuracy
Thermal stability
Linearity
±0,005%/°C
±0,1%
INPUT DATA
Nr
Type
1 (isolated)
Sensor reed (contact), npn 2-3 wire (12/24 Vdc sensor
supply), pnp, namur (8 Vdc), 24 Vdc pulse, photoelectric
1
Current: 0-20 / 4-20 mA
Voltage: 0-5 / 1-5 / 0-10 / 2-10 Vdc
1
Current: 0-20 / 4-20 mA
Voltage: 0-5 / 1-5 / 0-10 / 2-10 Vdc
Frequency
Reset
Max 450 Hz, 1 ms (min pulse length)
Isolated (terminal contact, front key option)
Isolated (terminal contact, front key option)
Isolated (terminal contact, front key option)
1
Pulse repetition, transistor npn open collector 30 V, 300
mA; 40 ms (pulse length)
1
Pulse repetition, transistor npn open collector 30 V, 300
mA
-10..+50°C
Shockproof V0 self-extinguished ABS
Removable terminals
96 x 48 x 148 mm (DIN 43700)
92 x 45 mm
380 g
0..+50°C
Shockproof V0 self-extinguished ABS
Removable terminals
96 x 48 x 148 mm (DIN 43700)
92 x 45 mm
420 g
0..+50°C
Shockproof V0 self-extinguished Noryl
Removable terminals
96 x 48 x 148 mm (DIN 43700)
92 x 45 mm
420 g
Divisor circuit, programmable frequency 1..256
Decimal point
Input type
Integration scale
Integration coefficient (1 pulse per 27ʼ, 20 pulse/s)
CE
EN 50081-2, EN 50082-2
Via test or frequency meter
CE
EN 50081-2, EN 50082-2
Input type
Zero, full scale
Integration coefficient (1 pulse per 27ʼ, 20 pulse/s), decimal
point
Via test or frequency meter
CE
EN 50081-2, EN 50082-2
OUTPUT DATA
Nr
Type
THERMOMECHANICS DATA
Operating temperature
Case
Connections
Dimension (w x h x d)
Panel dimension (w x h)
Weight
SETTINGS, NORMS
DIP switch
Trimmer
Jumper / shunt
Calibration
Conformity
Norms
ORDER CODES
Code
Model
S114
S114B
-4 / -6 / -8
Display
Power supply
-1-ST
-23-ST
Code
Model
Display
Power supply
S144I
Code
Model
Power supply
S164
-6 / -8
-1-ST
-23-ST
*Available until stocks last
-1-ST
-23-ST
Description
Totalizer with divider and universal input
Bi-directional totalizers with divider and universal input
4 / 6 / 8 digit
115 / 230 Vac
24 Vac/dc
Description
Totalizer with integrator, analog input, pulse output
6 / 8 digit
115 / 230 Vac
24 Vac/dc
Description
7 digit totalizer with 3 ½ digit indicator
115 / 230 Vac
24 Vac/dc
57
S20N
S21
S30
S6000
Batch controller
Batch controller
with clock
Advanced
batch controller
Control unit
pump controller
115 / 230 Vac ± 50-60 Hz; 24 Vac/dc
12/ 24 Vdc, 30 mA (max)
12 VA
115 / 230 Vac ± 50-60 Hz; 24 Vac/dc
24 Vdc, 30 mA
10 VA
RS232 / RS485 serial interface (option)
Parallel interface for S30 printer (option)
Isolated RS232 (programming, PC connection)
GENERAL DATA
115 / 230 Vac ± 50-60 Hz; 24 Vac/dc
12/ 24 Vdc, 30 mA (max)
10 VA
EEPROM, data
Power supply
Power transducers
Max consumption
Data storage
Clock
115 / 230 Vac ± 50-60 Hz; 24 Vac/dc
12/ 24 Vdc, 30 mA (max)
10 VA
EEPROM, data
Clock with battery and data storage, hour
automatic correction
Interface
INDUSTRIAL I/O’S
AND TELECONTROL
S-LINE BATCH CONTROLLERS AND CONTROL UNITS
2 numeric display
5 digit LED
Start, stop, reset
2 numeric display
5 digit LED
7 operating status LED
2 numeric display
5 digit LED
7 operating status LED
LCD back lightened display
2 raws x 16 chars
18 LED: motor status, alarms
±0,005% /°C
±0,1%
Nr
Type
1 (isolated)
From sensor: reed, npn (2-3 wire), namur,
hall effect, photoelectric
1 (isolated)
Contact or sensor: reed, npn (2-3 wire),
pnp, 12/24 V pulse, namur, hall effect, photoelectric
1 (isolated)
Contact or sensor: reed, npn (2-3 wire),
pnp, 12/24 V pulse, namur, hall effect, photoelectric
8 (isolated)
Nr 6 digital contacts
Nr 2 analog signals (0..20, 4..20 mA; input
resistance 100 Ω, resolution 200 points)
Frequency
Control
1.000 Hz, min pulse duration 0,1 ms
3 input (start, stop, reset)
3 input (start, stop, reset)
3 input (start, stop, reset)
2
SPDT relay, 5 A 250 V (resistive load)
2
SPDT relay, 5 A 250 V (resistive load)
2
SPDT relay, 5 A 250 V (resistive load)
10
Nr 1 digital contacts open collector
Nr1 SPDT relay 5 A 250 Vac (signalling)
Nr 6 SPST relay, 5 A 250 Vac (actuators)
Nr 2 analog signals (0..20, 4..20 mA; 0..10
V; resolution 4.000 points)
Status indicators
Thermal stability
Linearity
INPUT DATA
CONVERTERS
AND INTERFACES
VISUALIZATION AND MEASURE
Display
Nr
Type
THERMOMECHANICS DATA
Operating temperature
Case
Front protection
Connections
0..50 °C
Noryl self-extinguished V0
Polycarbonate membrane
Back removable terminals
0..50 °C
Noryl self-extinguished V0
Polycarbonate membrane
Back removable terminals
0..50 °C
Noryl self-extinguished V0
Polycarbonate membrane
Back removable terminals
Dimension (w x h x d)
Panel dimension
Weight
144 x 72 x 130 mm
135 x 67 mm
800 g
144 x 72 x 130 mm
135 x 67 mm
800 g
144 x 72 x 130 mm
135 x 67 mm
1,2 kg
0..50 °C
Noryl self-extinguished V0
Polycarbonate membrane
Back removable terminals, serial interface
DB9 connector
144 x 72 x 121 mm
135 x 67 mm
800 g
Programming, metering
CE
Programming, metering
CE
Programming, metering
CE
SOF6000
Programming
CE
DIGITAL
DISPLAYS
OUTPUT DATA
SETTINGS, NORMS
Software
Front keys
Conformity
S20N
S20NIP65
S20NEX
S20NKIT
S20ADP
S20ADP-CM
S20ADP-IP65
Accessories
Code
Model
S21
S21IP65
S21EX
S20ADP
S20ADP-CM
S20ADP-IP65
Accessories
Code
Model
S30
S30IP65
S30-STAMP
S20ADP
S20ADP-CM
S20ADP-IP65
Accessories
Code
Model
Power supply
S6000
-1-ST / -23-ST
Description
Batch controller
Batch controller in IP65 protected case
Batch controller in EExd flame retardant case
External kit
Input adapter board (hall effect / photoelectric sensor)
IP20 DIN rail input adapter board (hall effect / photoelectric sensor)
IP65 Input adapter board (hall effect / photoelectric sensor)
Description
Batch controller with clock
Batch controller with clock in IP65 protected case
Batch controller with clock in EExd flame retardant case
Input adapter board (hall effect / photoelectric sensor)
IP20 DIN rail input adapter board (hall effect / photoelectric sensor)
IP65 Input adapter board (hall effect / photoelectric sensor)
Description
Advanced batch controller
Advanced batch controller in IP65 protected case
Printer interface
Input adapter board (hall effect / photoelectric sensor)
IP20 DIN rail input adapter board (hall effect / photoelectric sensor)
IP65 Input adapter board (hall effect / photoelectric sensor)
Description
Control unit, pump controller
115 / 230 Vac / 24 Vac/dc
MEASUREMENT
DEVICES
ORDER CODES
Code
Model
DIGITAL DISPLAYS
58
ZTOP – LCD TOUCHSCREEN OPERATOR PANEL
ZTOP03
ZTOP05
Monochrome 3,8” LCD
touch display
Monochrome 5,6” LCD
touch display
ZTOP11
STN colour 5,6”
touch display
DISPLAY
Format
Backlight
Lifetime
Resolution
Active area
Raws x columns
Scalable fonts
User fonts
Contrast setting
Monochrome LCD
LED, white
50.000 hrs
320 x 240 pixel
77 x 58 mm (3,8”)
16 x 40
yes
256
Software
Monochrome LCD
LED, white
100.000 hrs
320 x 240 pixel
121 x 91 mm (5,6”)
16 x 40
yes
256
Software, temperature compensation
STN 16colours
CCFL
25.00 hrs
320 x 240 pixel
77 x 58 mm (5,6”)
16 x 40
Yes
256
Software, temperature compensation
512 kB Flash
32 MB SSFDC memory card
32 MB SSFDC memory card
Resistive
-
Resistive (3 milion operations)
5
Resistive (3 milion operations)
5
RS232, RS422, RS485
Yes, with optional module
9.600 – 38.400 bps
RS232, RS422, RS485, 20 mA CL
Yes, with optional module
9.600 – 38.400 bps
RS232, RS422, RS485, 20 mA C
Yes, with optional module
9.600 – 38.400 bps
Unlimited
32 kB
1.024 + 256
Yes
Yes, 8 levels
3 V, 270 mA, Lithium, non rechargeable
yes
yes
Alarm, communication, battery, hardware fault
18..30 Vdc
400 mA
1 kg
0..50°C
-20..+70 °C
5..85% RH non condensing
IP65
149 x 109 mm (5,86 x 4,49 “); 136 x 96 mm (5,35 x 3,78“)
61 mm (2,4”)
5 mm (0,2”)
Unlimited
32 kB
1.024 + 1.024
Yes
Yes
Yes, backup battery
yes
yes
yes
Alarm, communication, battery, hardware fault
18..30 Vdc
600 mA @ 24 Vdc
1,4 kg
0..45°C
-20..+70 °C
5..85% RH non condensing
IP65
187 x 147 mm (7,36 x 5,79 “); 176 x 136 mm (6,93 x5,35“)
79 mm (3,12”)
5 mm (0,2”)
Unlimited
32 kB
1.024 + 1.024
Yes
Yes, 8 levels
Yes, backup battery
yes
yes
yes
Alarm, communication, battery, hardware fault
18..30 Vdc
600 mA @ 24 Vdc
1,4 kg
0..45°C
-20..+70 °C
5..85% RH non condensing
IP65
187 x 147 mm (7,36 x 5,79 “); 176 x 136 mm (6,93 x 5,35“)
79 mm (3,12”)
5 mm (0,2”)
MEMORY
User memory
FRONT PANEL
Touch screen
System LEDs
CONNECTIONS
PC / printer port
PLC port
Aux (Fieldbus / Ethernet)
Programming speed
GENERAL DATA
Nr variables / page
Recipes memory
Alarms + Events
Alarms info page
Password
Battery
RTC hardware
Screen saver
Buzzer
LED indicators
Power supply
Max consumption
Weight
Operating temperature
Storage temperature
Humidity
Protection degree
Dimension (w x h x d)
Depth
Max thickness
ORDER CODES
Code
Models
Programming
Connections
ZTOP03
ZTOP05
ZTOP11
ZTOPKIT
PM001810
UniOP
PM001820
PM001830
PM001840
PM001850
Description
Monochrome LCD touchscreen graphical panel 3,8”
Monochrome LCD touchscreen graphical panel 5,6”
STN colour touchscreen graphical panel 5,6”
Full programming toolkit: PM001810 + UniOP
Programming / download cable
Design software
Communication cable ZTOP – ZRTU
Communication cable ZTOP – ZTWS
Communication cable ZTOP – RS485 bus
PM001810 adapter for ZTOP05 / ZTOP11
59
SPECIFICHE TECNICHE
Z109REG
CODICI DʼORDINE
• Z109REG (24 Vdc/ac)
• Z109REG-ER (24 Vdc/ac) - estrazione di radice già programmata
ELETTRICHE
Alimentazione
4
CONFIGURAZIONE E NORME
Programmazione software
• Lettura, configurazione, download e salvataggio
DIP Switch
• Tipo, zero e span ingresso
• Tipo uscita
Norme CE
EN50081-2, EN50082-2, EN61010-1
COMUNICAZIONE, ELABORAZIONE, MEMORIA
Campionamento
3 letture al secondo
Memoria dati
EEPROM per i parametri di configurazione, tempo ritenuta 10 anni
Ingresso e uscita (tipo e range)• Termocoppia - J: -200..+1000°C; K: -200..+1300°C;
R: 50..+1750°C; S: -50..+1750°C; T: -200..+ 400°C; E: 150..+800°C; B: 0..+1800°C; N: -200..+1300 °C;
• Termoresistenza - Pt100 -200..+600 °C
• Potenziometro: 0,5..15 Kø
• Tensione (bipolari) 0..200 mV; 0..2, 0..5; 0..10 V
• Corrente (bipolari) 0..20 mA
Impedenza di ingresso
• 2.5 ø in corrente
• 1 Mø in tensione
Risoluzione di ingresso
• Termocoppia: risoluzione 5 ÌV, rilevamento
automatico interruzione TC
• Termoresistenza: misura a 3 fili, corrente di eccitazione 0.56 mA,
risoluzione 0.1 °C, rilevamento automatico interruzione cavi o RTD
• Potenziometro: fondo scala min. 500 ø, risoluzione 0,01 % ds
• Tensione :risoluzione 0.01 %ds
• Corrente: risoluzione 0.01 %ds
Impedenza di uscita
• Impedenza loop in corrente 0..600 ø
• Carico per uscita in tensione > 2.5 Kø
Risoluzione di uscita
• 0.025% per 0..20 mA / 0..10 V / 0..5 V
• 0.032% per 4..20 mA / 2..10 V / 1..5 V
Errori
• Precisione 0.2 %ds. in tensione e corrente, 0.2 % altrimenti
• Linearità: 0.05 % per ingresso in tensione, corrente e potenziometro,
0.2°C per termoresistenza, 1°C per termocoppie salvo 3°C per TCB
oltre 600°C
• Stabilità termica: 0.02%/°C
• Compensazione giunto freddo: 2°C tra 10 e 40°C
DIMENSIONI E INGOMBRI
COLLEGAMENTI ELETTRICI
Assorbimento max
Isolamento
Protezione
Alimentazione trasduttori
Indicatori di stato
Categoria di installazione
Grado di inquinamento
Grado di protezione
• 19..40 Vdc / 19 - 28 Vac, 50-60 Hz
• 9..30 Vdc (opzionale)
2.5 W
Alimentazione // ingresso // uscita: 1.500 Vac
• Ingressi: in corrente 200 mA continuativi, rimanenti 60 V continuativi
• Alimentazione e uscite: contro sovratensioni impulsive 400 W/ms
min 18 Vdc 20 mA
• Power
• Error
II
2
IP20
TERMOMECCANICHE
Temperatura
Funzionam.: 0..+ 50°C
Umidità
30..90 % a +40 °C (non condensante)
Peso
200 g circa
Custodia
Nylon 6 caricato 30 % fibra vetro – classe autoestinguenza V0
Connessioni
Morsetti estraibili polarizzati a vite per conduttori fino a 2.5 mm2
Montaggio
Guida 35 mm DIN 46277
ALIMENTAZIONE
MEASUREMENT
DEVICES
La tensione di alimentazione deve essere compresa tra 10 e 40 Vdc), o tra 12 e
28 Vac. I limiti superiori non devono
essere superati, pena gravi danni al
modulo.
INTERFACCIA SERIALE
Il collegamento per lʼinterfaccia seriale e
per lʼalimentazione del modulo è presente anche nel con-nettore sul fondo dello
strumento e ne permette il collegamento
in bus tramite lʼapposito supporto da installare nella guida DIN
USCITE
MEASUREMENT DEVICES
60
TEST & MEASUREMENT
TEST-3
Handheld multimeter - configurator with Oled display
• Accuracy class: 0.1%
• Voltage signal measure / generation: 0-10 V
• Current signal measure / generation: 0-20 mA
• Function setting via encoder button
• High brightness Oled display, 128 x 64 points resolution
• Graphic menu with 5 language interface
• Power supply: 2 batteries NiMh-type AA 2.650 mAh, medium life-time 20 h
• Z109REG2 programming
ORDER CODES
Code
Version
TEST-3
TEST-3-PK
TEST-3/S
Description
Handheld device with compact bag , standard probes, battery charger
Precision kit (precision probes set with adapters and crocodile terminals)
Calibration service
DL
Datalogger with IP65 case
• Input: mV, Volt, mA, pulses
• Output: RS232 serial connection
• A/D converter resolution: 8 bit
• Sampling time: from 1 minute-second to 10 days
• Alarms: 2 free settable
• Battery life-time from 2 to 5 years
• Dimensions: 80 x 82 x 55 mm
• Configuration software, recording and data download
ORDER CODES
Code
Version
DL-mA
DL-mV
DL-V
DL-COUNT
SOFT-OTLM
SOFT-EDUC
Description
mA Input Datalogger
mV Input Datalogger
V Input Datalogger
Pulses input
Logger Manager, standard software
Logger Manager re-educator software
PT100
Thermoprobes (RTD)
• Thermoresistance Pt100 3 wires with standard alluminium case
• Process connection 1/2” G.M., Sheat diam.: 6 mm
• Sensor wetted parts: AISI 316, Ohm output
• Atmosphere probe model (ABS, IP65), wall mounting
ORDER CODES
Code
Version
PT100-50
PT100-100
PT100-150
PT100-200
PT100-…
-mA
PT100-A
Description
Pt100 std Lenght 50 mm
Pt100 std Lenght 100 mm
Pt100 std Lenght150 mm
Pt100 std Lenght 200 mm
Extension Pt100 10 mm
Opt. output 4-20mA
Pt100 Atmosphere
ORDER CODES
Code
Version
POZZ-50
POZZ-100
POZZ-150
POZZ-200
POZZ-…
Description
Shaft Lenght. 50 mm
Shaft Lenght. 100 mm
Shaft Lenght. 150 mm
Shaft Lenght. 200 mm
Extension Lenght 10 mm
61
Three-Phase Advanced Network Analyzer
Input up to 5 Arms
• Power supply: 10–40 Vdc, 19–28 Vac 50-60 Hz
• Serial interface: RS485 isolated, ModBUS/RTU
protocol
• Voltage input: capacity measure=600 Vac,
freq. 50 or 60Hz
• Current input: up to 100 mA
• Re-transmitted output by voltage / current
(error max 0,1%)
• Accuracy class: 0,2
• Power supply: 10–40 Vdc, 19–28 Vac 50-60 Hz
• Serial interface: RS485 isolated,ModBUS/RTU
protocol
• Voltage input: max=600 Vac,
freq. 50 or 60Hz
• Current input: up to 5 Arms
• Re-transmission as analogue output voltage /
current (error max 0,1%)
• Accuracy class: 0,2
ORDER CODE
Code
Description
Version
S203T Three-Phase Network Analyzer (class. 0,2), suitable for CT
(accuracy 0.1%) with secondary circuit max 100 mA
Accessories TA15 Current Transformer for S203T, f.s.15 A, accuracy 0,1% (1/1000)
S203T
TA25 Curr. Transformer for S203T, f.s.25 A, accuracy 0,1% (1/1000)
TA100 Curr. Transformer for S203T, f.s.100 A, accuracy 0,1% (1/1000)
ORDER CODE
Code
Description
Version
S203TA Three-Phase Network Analyzer (class 0,2), suitable for common Current
Transformer (Accuracy 0.5%) with output max 5 A
Z203
E2002
Single-Phase Network Analyzer
Universal Network Analyzer
• Power supply: 9..40 Vdc; 8..28 Vac - 50-60 Hz
• Input: voltage 0..500 Vac, current 0..5 A
• Output: current 0..20 / 4..20 mA; voltage 0..5 /
0..10 / 1..5 / 2..10 V
• Accuracy: 0.5%
• Isolation: 3.750 Vac (from/to power); 1.500 Vac
(other circuits)
• Dimension (w x h x d): 17,5 x 100 x 112 mm
• Simultaneously data acquisition of RMS
parameters voltage, current, cosФ, power,
energy, harmonic distortion...
• Class 0,5
• 2 pulse outputs for energy and alarms
• RS485 serial interface, 3 communication
protocols
• Dimensions: 6 DIN modules
ORDER CODE
Code
Z203
ORDER CODE
Code
Description
E2002-2-M
Universal Network Analyzer, 115 / 230 Vac
E2002-4-M
Universal Network Analyzer, 72x144 mm, 24 Vac
E2002-3-M
Universal Network Analyzer, 72x144 mm, 12/24/48/110 Vdc
-FL
Panel Mounting Tool
Description
Single Phase Network Analyzer, power 10..40 Vdc/ 19..28 Vac
E92002
E742002
Universal Network Analyzer (panel mounting)
Universal Network Analyzer (Panel Mounting)
• Simultaneously RMS data acquisition of voltages, currents, CosФ, power, energy, harmonic
distortion…
• Class 0,5
• 2 pulse outputs / relays for energy and alarms
• RS485 serial interface, 3 communication protocols
• Panel mounting (96 x 96 mm)
• Simultaneously data acquisition of RMS
parameters voltage, current, cosФ, power,
Energy, harmonic distortion...
• Class 0,5
• 2 pulse outputs for energy and alarms
• RS485 serial interface, 3 communication
protocols
• Panel mounting (72 x 144 mm)
ORDER CODE
Code
Description
E92002-2
Panel Mounting Network Analyzer, 96x96 mm, 115 / 230 Vac
E92002-4
Panel Mounting Network Analyzer, 96x96 mm, 24 Vac
E92002-3
Panel Mounting Network Analyzer, 96x96 mm, 12/24/48/110 Vdc
ORDER CODE
Code
Description
E742002-2
Panel Mounting Network Analyzer, 72x144 mm, 115 / 230 Vac
E742002-4
Panel Mounting Network Analyzer, 72x144 mm, 24 Vac
E742002-3
Panel Mounting Network Analyzer, 72x144 mm, 12/24/48/110 Vdc
CONVERTERS
AND INTERFACES
Advanced Three-Phases Network Analyzer
(input up to 100 mA)
DIGITAL
DISPLAYS
S203TA
MEASUREMENT
DEVICES
S203T
INDUSTRIAL I/O’S
AND TELECONTROL
NETWORK ANALYZER
62
QUALITY SYSTEM AND TECHNOLOGICAL STANDARDS
SENECA operates according to quality standard, compliant to ISO
9001 since 1997 in “design and manufacturing of system and electronic instrumentation for control, data transmission and interface
for automation”.
Our products are approved CE, UL and UR for the North American
market and they offer RINA certification for applications in shipbuilding. Our manufacturing process, undertaken by SMT technology automated lines, is compliant to RAEE and ROHS lead free
SENECA ON THE WEB
SENECA offers an interactive
website and a large database
useful for every customer need:
technical and sales info, catalogues, data sheets, operating
manuals, software, online technical support, sales network,
news, internal site search, quick
product selector. Everything
user-friendly, downloadable and
continuously updated.
www.seneca. it
www.seneca.it/impianti
www.seneca-forniture.it
international standards.
The safety standards, electromagnetic compatibility and protection
Electric are compliant to CE, IEC, EN approvals.
Software and communication tools for our instruments are developed and updated according to international recognized standards
(eg, IEC 61131, Modbus RTU / TCP, IEC 870, CANopen, PPP,
SMTP, HTML, OPC Server).
Via Germania 34 - 35127 Padova - Italy • Tel. +39 049 8705 359 (.408) • Fax +39 049 8706287 • www.seneca.it • [email protected]
This document is property of SENECA srl. Duplication and reproduction are forbidden, if not authorized. Content of the present documentation refers to products and technologies described in it. All technical
data contained in the document may be modified without prior notice. Content of this documentation is subject to periodical revision. For any further information and explanations, please do not hesitate to contact us and send an e-mail to [email protected]
Publication C00810EN – October 2008
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement